WorldWideScience

Sample records for fr26mr10r pp 14819-14868

  1. Rosen's (M,R) system in process algebra.

    Science.gov (United States)

    Gatherer, Derek; Galpin, Vashti

    2013-11-17

    Robert Rosen's Metabolism-Replacement, or (M,R), system can be represented as a compact network structure with a single source and three products derived from that source in three consecutive reactions. (M,R) has been claimed to be non-reducible to its components and algorithmically non-computable, in the sense of not being evaluable as a function by a Turing machine. If (M,R)-like structures are present in real biological networks, this suggests that many biological networks will be non-computable, with implications for those branches of systems biology that rely on in silico modelling for predictive purposes. We instantiate (M,R) using the process algebra Bio-PEPA, and discuss the extent to which our model represents a true realization of (M,R). We observe that under some starting conditions and parameter values, stable states can be achieved. Although formal demonstration of algorithmic computability remains elusive for (M,R), we discuss the extent to which our Bio-PEPA representation of (M,R) allows us to sidestep Rosen's fundamental objections to computational systems biology. We argue that the behaviour of (M,R) in Bio-PEPA shows life-like properties.

  2. 26 CFR 1.414(r)-10 - Separate application of section 129(d)(8). [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Separate application of section 129(d)(8). [Reserved] 1.414(r)-10 Section 1.414(r)-10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE.... § 1.414(r)-10 Separate application of section 129(d)(8). [Reserved] ...

  3. Rosen's (M,R) system in Unified Modelling Language.

    Science.gov (United States)

    Zhang, Ling; Williams, Richard A; Gatherer, Derek

    2016-01-01

    Robert Rosen's (M,R) system is an abstract biological network architecture that is allegedly non-computable on a Turing machine. If (M,R) is truly non-computable, there are serious implications for the modelling of large biological networks in computer software. A body of work has now accumulated addressing Rosen's claim concerning (M,R) by attempting to instantiate it in various software systems. However, a conclusive refutation has remained elusive, principally since none of the attempts to date have unambiguously avoided the critique that they have altered the properties of (M,R) in the coding process, producing merely approximate simulations of (M,R) rather than true computational models. In this paper, we use the Unified Modelling Language (UML), a diagrammatic notation standard, to express (M,R) as a system of objects having attributes, functions and relations. We believe that this instantiates (M,R) in such a way than none of the original properties of the system are corrupted in the process. Crucially, we demonstrate that (M,R) as classically represented in the relational biology literature is implicitly a UML communication diagram. Furthermore, since UML is formally compatible with object-oriented computing languages, instantiation of (M,R) in UML strongly implies its computability in object-oriented coding languages. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Generalisation for regular black holes on general relativity to f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Manuel E. [Universidade Federal do Para Campus Universitario de Abaetetuba, Faculdade de Ciencias Exatas e Tecnologia, Abaetetuba, Para (Brazil); Universidade Federal do Para, Faculdade de Fisica, PPGF, Belem, Para (Brazil); Fabris, Julio C. [Universidade Federal do Espirito Santo, Vitoria, ES (Brazil); National Research Nuclear University MEPhI, Moscow (Russian Federation); Junior, Ednaldo L.B. [Universidade Federal do Para, Faculdade de Fisica, PPGF, Belem, Para (Brazil); Universidade Federal do Para, Campus Universitario de Tucurui, Faculdade de Engenharia da Computacao, Tucurui, Para (Brazil); Marques, Glauber T. [Universidade Federal Rural da Amazonia ICIBE - LASIC, Belem, PA (Brazil)

    2016-05-15

    IIn this paper, we determine regular black hole solutions using a very general f(R) theory, coupled to a nonlinear electromagnetic field given by a Lagrangian L{sub NED}. The functions f(R) and L{sub NED} are in principle left unspecified. Instead, the model is constructed through a choice of the mass function M(r) presented in the metric coefficients. Solutions which have a regular behaviour of the geometric invariants are found. These solutions have two horizons, the event horizon and the Cauchy horizon. All energy conditions are satisfied in the whole space-time, except the strong energy condition (SEC), which is violated near the Cauchy horizon.We present also a new theorem related to the energy conditions in f(R) gravity, re-obtaining the well-known conditions in the context of general relativity when the geometry of the solution is the same. (orig.)

  5. A viable logarithmic f(R) model for inflation

    Energy Technology Data Exchange (ETDEWEB)

    Amin, M.; Khalil, S. [Center for Fundamental Physics, Zewail City of Science and Technology,6 October City, Giza (Egypt); Salah, M. [Center for Fundamental Physics, Zewail City of Science and Technology,6 October City, Giza (Egypt); Department of Mathematics, Faculty of Science, Cairo University,Giza (Egypt)

    2016-08-18

    Inflation in the framework of f(R) modified gravity is revisited. We study the conditions that f(R) should satisfy in order to lead to a viable inflationary model in the original form and in the Einstein frame. Based on these criteria we propose a new logarithmic model as a potential candidate for f(R) theories aiming to describe inflation consistent with observations from Planck satellite (2015). The model predicts scalar spectral index 0.9615r of order 10{sup −3}. Furthermore, we show that for a class of models, a natural coupling between inflation and a scalar boson is generated through the minimal coupling between gravity and matter fields and a reheating temperature less that 10{sup 9} GeV is obtained.

  6. The combinatorial PP1-binding consensus Motif (R/Kx( (0,1V/IxFxx(R/Kx(R/K is a new apoptotic signature.

    Directory of Open Access Journals (Sweden)

    Angélique N Godet

    Full Text Available BACKGROUND: Previous studies established that PP1 is a target for Bcl-2 proteins and an important regulator of apoptosis. The two distinct functional PP1 consensus docking motifs, R/Kx((0,1V/IxF and FxxR/KxR/K, involved in PP1 binding and cell death were previously characterized in the BH1 and BH3 domains of some Bcl-2 proteins. PRINCIPAL FINDINGS: In this study, we demonstrate that DPT-AIF(1, a peptide containing the AIF(562-571 sequence located in a c-terminal domain of AIF, is a new PP1 interacting and cell penetrating molecule. We also showed that DPT-AIF(1 provoked apoptosis in several human cell lines. Furthermore, DPT-APAF(1 a bi-partite cell penetrating peptide containing APAF-1(122-131, a non penetrating sequence from APAF-1 protein, linked to our previously described DPT-sh1 peptide shuttle, is also a PP1-interacting death molecule. Both AIF(562-571 and APAF-1(122-131 sequences contain a common R/Kx((0,1V/IxFxxR/KxR/K motif, shared by several proteins involved in control of cell survival pathways. This motif combines the two distinct PP1c consensus docking motifs initially identified in some Bcl-2 proteins. Interestingly DPT-AIF(2 and DPT-APAF(2 that carry a F to A mutation within this combinatorial motif, no longer exhibited any PP1c binding or apoptotic effects. Moreover the F to A mutation in DPT-AIF(2 also suppressed cell penetration. CONCLUSION: These results indicate that the combinatorial PP1c docking motif R/Kx((0,1V/IxFxxR/KxR/K, deduced from AIF(562-571 and APAF-1(122-131 sequences, is a new PP1c-dependent Apoptotic Signature. This motif is also a new tool for drug design that could be used to characterize potential anti-tumour molecules.

  7. Molecular mechanism of serine/threonine protein phosphatase 1 (PP1cα-PP1r7) in spermatogenesis of Toxocara canis.

    Science.gov (United States)

    Ma, Guang Xu; Zhou, Rong Qiong; Song, Zhen Hui; Zhu, Hong Hong; Zhou, Zuo Yong; Zeng, Yuan Qin

    2015-09-01

    Toxocariasis is one of the most important, but neglected, zoonoses, which is mainly caused by Toxocara canis. To better understand the role of serine/threonine protein phosphatase 1 (PP1) in reproductive processes of male adult T. canis, differential expression analysis was used to reveal the profiles of PP1 catalytic subunit α (PP1cα) gene Tc-stp-1 and PP1 regulatory subunit 7 (PP1r7) gene TcM-1309. Indirect fluorescence immunocytochemistry was carried out to determine the subcellular distribution of PP1cα. Double-stranded RNA interference (RNAi) assays were employed to illustrate the function and mechanism of PP1cα in male adult reproduction. Real-time quantitative PCR (qPCR) showed transcriptional consistency of Tc-stp-1 and TcM-1309 in sperm-producing germline tissues and localization research showed cytoplasmic distribution of PP1cα in sf9 cells, which indicated relevant involvements of PP1cα and PP1r7 in spermatogenesis. Moreover, spatiotemporal transcriptional differences of Tc-stp-1 were determined by gene knockdown analysis, which revealed abnormal morphologies and blocked meiotic divisions of spermatocytes by phenotypic aberration scanning, thereby highlighting the crucial involvement of PP1cα in spermatogenesis. These results revealed a PP1cα-PP1r7 mechanism by which PP1 regulates kinetochore-microtubule interactions in spermatogenesis and provided important clues to identify novel drug or vaccine targets for toxocariasis control. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Future dynamics in f(R) theories

    International Nuclear Information System (INIS)

    Mueller, D.; Andrade, V.C. de; Maia, C.; Reboucas, M.J.; Teixeira, A.F.F.

    2015-01-01

    The f(R) gravity theories provide an alternative way to explain the current cosmic acceleration without invoking a dark energy matter component used in the cosmological modeling in the framework of general relativity. However, the freedom in the choice of the functional forms of f(R) gives rise to the problem of the degeneracy among these gravity theories on theoretical and (or) observational grounds. In this paper we examine the question as to whether the future dynamics can be used to break the degeneracy between f(R) gravity theories by investigating the dynamics of spatially homogeneous and isotropic dust flat models in two f(R) gravity theories, namely the well known f(R) = R+αR n gravity and another byAviles et al., whose motivation comes from the cosmographic approach to f(R) gravity. We perform a detailed numerical study of the dynamics of these theories taking into account the recent constraints on the cosmological parameters made by the Planck Collaboration. We demonstrate that besides being useful for discriminating between these two f(R) gravity theories, the future dynamics technique can also be used to determine the finite-time behavior as well as the fate of the Universe in the framework of these f(R) gravity theories. There also emerges from our analysis the result that one still can have a dust flat FLRWsolution with a big rip, if gravity is governed by f(R) = R+αR n . We also show that FLRW dust solutions with f'' < 0 do not necessarily lead to singularities. (orig.)

  9. 42 CFR 408.26 - Examples.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Examples. 408.26 Section 408.26 Public Health... PREMIUMS FOR SUPPLEMENTARY MEDICAL INSURANCE Amount of Monthly Premiums § 408.26 Examples. Example 1. Mr. J... 10 percent greater than if he had enrolled in his initial enrollment period. Example 2. Mr. V, who...

  10. Nuclear trafficking of the human cytomegalovirus pp71 (ppUL82) tegument protein

    International Nuclear Information System (INIS)

    Shen Weiping; Westgard, Elizabeth; Huang Liqun; Ward, Michael D.; Osborn, Jodi L.; Chau, Nha H.; Collins, Lindsay; Marcum, Benjamin; Koach, Margaret A.; Bibbs, Jennifer; Semmes, O. John; Kerry, Julie A.

    2008-01-01

    The human cytomegalovirus tegument protein pp71 localizes to the nucleus immediately upon infection, and functions to initiate viral gene expression. Analysis of a series of random insertion mutations revealed that sequences within the mid region (MR) of pp71 are important for localization to the nucleus. Fusion of MR sequences with eGFP revealed that amino acids 94 to 300 were sufficient to target proteins to the nucleus. Random substitution mutagenesis within this domain resulted in two double substitution mutants, pp71P203T/T223M and pp71T228M/L275Q, with a predominantly cytoplasmic localization. Disruption of nuclear targeting resulted in relocalization of the fusion proteins to a distinct perinuclear region. Using tandem mass spectrometry, we determined that threonine 223 can be phosphorylated. Mutation of this residue to a phosphomimetic amino acid resulted in abrogation of nuclear targeting. These results strongly suggest that the intracellular trafficking of pp71 is regulated by phosphorylation

  11. Digitaalisen markkinoinnin suunnitelma : Case NäppäräNäppi

    OpenAIRE

    Komulainen, Pia

    2017-01-01

    Toiminnallisessa opinnäytetyössä laadittiin digitaalisen markkinoinnin suunnitelma NäppäräNäpille, joka on askartelun erikoisliike Iisalmessa. Digitaalinen markkinointi on muuttanut yritysten markkinointitoimenpiteitä ja se tarjoaa perinteisiä markkinoinnin kanavia edullisempia vaihtoehtoja. Digitaaliset kanavat kuten sosiaalinen media, verkkosivut ja blogi ovat tehokkaita ja moderneja työkaluja NäppäräNäpin markkinoinille. Työn tavoitteena oli selvittää, digitaalinen markkinointi on, mit...

  12. Buli. Mater. Sci., Vol. 10, No. 4, July 1988, pp. 367-372. (C

    Indian Academy of Sciences (India)

    Mater. Sci., Vol. 10, No. 4, July 1988, pp. 367-372. (C) Printed in India. Studies on iron-chromium redox storage system. SH PAWAR, R D MADHALE, P S PATIL and CD LOKHANDE. Department of Physics, Shivaji University, Kolhapur 416 004, India. Abstract. The performance of the redox storage battery based on the Fe-Cr ...

  13. f(R) gravity solutions for evolving wormholes

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Subhra [Presidency University, Department of Mathematics, Kolkata (India); Chakraborty, Subenoy [Jadavpur University, Department of Mathematics, Kolkata (India)

    2017-08-15

    The scalar-tensor f(R) theory of gravity is considered in the framework of a simple inhomogeneous space-time model. In this research we use the reconstruction technique to look for possible evolving wormhole solutions within viable f(R) gravity formalism. These f(R) models are then constrained so that they are consistent with existing experimental data. Energy conditions related to the matter threading the wormhole are analyzed graphically and are in general found to obey the null energy conditions (NEC) in regions around the throat, while in the limit f(R) = R, NEC can be violated at large in regions around the throat. (orig.)

  14. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  15. MR evaluation of CSF fistulae

    International Nuclear Information System (INIS)

    Gupta, V.; Goyal, M.; Mishra, N.; Gaikwad, S.; Sharma, A.

    1997-01-01

    Purpose: To evaluate the role of MR imaging in the localisation of cerebrospinal fluid (CSF) fistulae. Material and Methods: A total of 36 consecutive unselected patients with either clincally proven CSF leakage (n=26) or suspected CSF fistula (n=10) were prospectively evaluated by MR. All MR examinations included fast spin-echo T2-weighted images in the 3 orthogonal planes. Thin-section CT was performed following equivocal or negative MR examination. MR and CT findings were correlated with surgical results in 33 patients. Results: CSF fistula was visualised as a dural-bone defect with hyperintense fluid signal continuous with that in the basal cisterns on T2-weighted images. MR was positive in 26 cases, in 24 of which the fistula was confirmed surgically. In 2 patients the CSF leakage was directly demonstrated on MR. MR sensitivity of 80% compared favourably with the reported 46-81% of CT cisternography (CTC). No significant difference in MR sensitivity in detecting CSF fistula was found between active and inactive leaks. (orig.)

  16. S A R Hashmi

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. S A R Hashmi. Articles written in Bulletin of Materials Science. Volume 26 Issue 6 October 2003 pp 579-583 Tribological Materials. Role of PET in improving wear properties of PP in dry sliding condition · Somit Neogi S A R Hashmi Navin Chand · More Details Abstract Fulltext ...

  17. Advanced design of fast reactor-membrane reformer (FR-MR)

    International Nuclear Information System (INIS)

    Tashimo, M.; Hori, I.; Yasuda, I.; Shirasaki, Y.; Kobayashi, K.

    2004-01-01

    A new plant concept of nuclear-produced hydrogen is being studied using a Fast Reactor-Membrane Reformer (FR-MR). The conventional steam methane reforming (SMR) system is a three-stage process. The first stage includes the reforming, the second contains a shift reaction and the third is the separation process. The reforming process requires high temperatures of 800 ∼ 900 deg C. The shift process generates heat and is performed at around 200 deg C. The membrane reforming has only one process stage under a nonequilibrium condition by removing H2 selectively through a membrane tube. The steam reforming temperature can be decreased from 800 deg C to 550 deg C, which is a remarkable benefit offered by the non-equilibrium condition. With this new technology, the reactor type can be changed from a High Temperature Gas-cooled Reactor (HTGR) to a Fast Reactor (FR). A Fast Reactor-Membrane Reformer (FR-MR) is composed of a nuclear plant and a hydrogen plant. The nuclear plant is a sodium-cooled Fast Reactor with mixed oxide fuel and with a power of 240 MWt. The heat transport system contains two circuits, the primary circuit and the secondary circuit. The membrane reformer units are set in the secondary circuit. The heat, supplied by the sodium, can produce 200 000 Nm 3 /h by 2 units. There are two types of membranes. One is made of Pd another one (advanced) is made of, for example V, or Nb. The technology for the Pd membrane is already established in a small scale. The non-Pd type is expected to improve the performance. (author)

  18. Exploring plane-symmetric solutions in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M. F., E-mail: farasat.shamir@nu.edu.pk [National University of Computer and Emerging Sciences, Department of Sciences and Humanities (Pakistan)

    2016-02-15

    The modified theories of gravity, especially the f(R) gravity, have attracted much attention in the last decade. This paper is devoted to exploring plane-symmetric solutions in the context of metric f(R) gravity. We extend the work on static plane-symmetric vacuum solutions in f(R) gravity already available in the literature [1, 2]. The modified field equations are solved using the assumptions of both constant and nonconstant scalar curvature. Some well-known solutions are recovered with power-law and logarithmic forms of f(R) models.

  19. 76 FR 2618 - Minnesota: Final Authorization of State Hazardous Waste Management Program Revision

    Science.gov (United States)

    2011-01-14

    ... Contaminated Cadmium-, Mercury-, and Silver-Containing Batteries Checklist 201. Hazardous Waste Management June... Restrictions May 26, 1998, 63 MR 7045.1390; Phase IV; Hazardous Soils FR 28556. Effective June 22, Treatment...); Effective February 14, 2005. Hazardous Remediation Waste November 30, MR 7001.0060; Management Requirements...

  20. Multiple R2R3-MYB transcription factors involved in the regulation of anthocyanin accumulation in peach flower

    Directory of Open Access Journals (Sweden)

    Hui Zhou

    2016-10-01

    Full Text Available Anthocyanin accumulation is responsible for flower coloration in peach. Here, we report the identification and functional characterization of eight flavonoid-related R2R3-MYB transcription factors, designated PpMYB10.2, PpMYB9, PpMYBPA1, Peace, PpMYB17, PpMYB18, PpMYB19 and PpMYB20, respectively, in peach flower transcriptome. PpMYB10.2 and PpMYB9 are able to activate transcription of anthocyanin biosynthetic genes, whilst PpMYBPA1 and Peace have a strong activation on the promoters of proanthocyanin (PA biosynthetic genes. PpMYB17-20 show a strong repressive effect on transcription of flavonoid pathway genes such as DFR. These results indicate that anthocyanin accumulation in peach flower is coordinately regulated by a set of R2R3-MYB genes. In addition, PpMYB9 and PpMYB10.2 are closely related but separated into two groups, designated MYB9 and MYB10, respectively. PpMYB9 shows a strong activation on the PpUGT78A2 promoter, but with no effect on the promoter of PpUGT78B (commonly called PpUFGT in previous studies. In contrast, PpMYB10.2 is able to activate the PpUFGT promoter, but not for the PpUGT78A2 promoter. Unlike the MYB10 gene that is universally present in plants, the MYB9 gene is lost in most dicot species. Therefore, the PpMYB9 gene represents a novel group of anthocyanin-related MYB activators, which may have diverged in function from the MYB10 genes. Our study will aid in understanding the complex mechanism regulating floral pigmentation in peach and functional divergence of the R2R3-MYB gene family in plants.

  1. Collected Reprints-1975. Volume I.

    Science.gov (United States)

    1977-02-01

    1972 . Geo log ic a s p e c t s of was t e s o l i d s and m a r i n e w a s t e d e p o s i t s N ew York m e t r o p o l i t a n reg io n . Bull ...cli) STATION NUMpFR 011. ~;E(-’T~ Mr~F~’ 143, 1. 71 13.2 “ LATT TIPOE 16 30 LONr.!TUL)~ 52 5~P rEPTH 10 430110M 1239 ‘A...studies in the Florida Current. Bull . Mar. Sci. Gulf and Carib., 13 (4), pp. 527—541. Corwin, T. L., and H. R. Ri~har dson (1974) , Preliminary Report

  2. Disentangling the f(R). Duality

    International Nuclear Information System (INIS)

    Broy, Benedict J.; Westphal, Alexander; Pedro, Francisco G.; Univ. Autonoma de Madrid

    2014-11-01

    Motivated by UV realisations of Starobinsky-like inflation models, we study generic exponential plateau-like potentials to understand whether an exact f(R)-formulation may still be obtained when the asymptotic shift-symmetry of the potential is broken for larger field values. Potentials which break the shift symmetry with rising exponentials at large field values only allow for corresponding f(R)-descriptions with a leading order term R n with 1 2 -term survives as part of a series expansion of the function f(R) and thus cannot maintain a plateau for all field values. We further find a lean and instructive way to obtain a function f(R) describing m 2 φ 2 -inflation which breaks the shift symmetry with a monomial, and corresponds to effectively logarithmic corrections to an R+R 2 model. These examples emphasise that higher order terms in f(R)-theory may not be neglected if they are present at all. Additionally, we relate the function f(R) corresponding to chaotic inflation to a more general Jordan frame set-up. In addition, we consider f(R)-duals of two given UV examples, both from supergravity and string theory. Finally, we outline the CMB phenomenology of these models which show effects of power suppression at low-l.

  3. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  4. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  5. The PP4R1 sub-unit of protein phosphatase PP4 is essential for inhibition of NF-κB by merkel polyomavirus small tumour antigen.

    Science.gov (United States)

    Abdul-Sada, Hussein; Müller, Marietta; Mehta, Rajni; Toth, Rachel; Arthur, J Simon C; Whitehouse, Adrian; Macdonald, Andrew

    2017-04-11

    Merkel cell carcinoma (MCC) is a highly aggressive skin cancer with a high metastatic potential. The majority of MCC cases are caused by the Merkel cell polyomavirus (MCPyV), through expression of the virus-encoded tumour antigens. Whilst mechanisms attributing tumour antigen expression to transformation are being uncovered, little is known of the mechanisms by which MCPyV persists in the host. We previously identified the MCPyV small T antigen (tAg) as a novel inhibitor of nuclear factor kappa B (NF-kB) signalling and a modulator of the host anti-viral response. Here we demonstrate that regulation of NF-kB activation involves a previously undocumented interaction between tAg and regulatory sub-unit 1 of protein phosphatase 4 (PP4R1). Formation of a complex with PP4R1 and PP4c is required to bridge MCPyV tAg to the NEMO adaptor protein, allowing deactivation of the NF-kB pathway. Mutations in MCPyV tAg that fail to interact with components of this complex, or siRNA depletion of PP4R1, prevents tAg-mediated inhibition of NF-kB and pro-inflammatory cytokine production. Comparison of tAg binding partners from other human polyomavirus demonstrates that interactions with NEMO and PP4R1 are unique to MCPyV. Collectively, these data identify PP4R1 as a novel target for virus subversion of the host anti-viral response.

  6. Geodesic congruences in the Palatini f(R) theory

    International Nuclear Information System (INIS)

    Shojai, Fatimah; Shojai, Ali

    2008-01-01

    We shall investigate the properties of a congruence of geodesics in the framework of Palatini f(R) theories. We shall evaluate the modified geodesic deviation equation and the Raychaudhuri's equation and show that f(R) Palatini theories do not necessarily lead to attractive forces. Also, we shall study energy condition for f(R) Palatini gravity via a perturbative analysis of the Raychaudhuri's equation.

  7. Clustering of galaxies with f(R) gravity

    Science.gov (United States)

    Capozziello, Salvatore; Faizal, Mir; Hameeda, Mir; Pourhassan, Behnam; Salzano, Vincenzo; Upadhyay, Sudhaker

    2018-02-01

    Based on thermodynamics, we discuss the galactic clustering of expanding Universe by assuming the gravitational interaction through the modified Newton's potential given by f(R) gravity. We compute the corrected N-particle partition function analytically. The corrected partition function leads to more exact equations of state of the system. By assuming that the system follows quasi-equilibrium, we derive the exact distribution function that exhibits the f(R) correction. Moreover, we evaluate the critical temperature and discuss the stability of the system. We observe the effects of correction of f(R) gravity on the power-law behaviour of particle-particle correlation function also. In order to check the feasibility of an f(R) gravity approach to the clustering of galaxies, we compare our results with an observational galaxy cluster catalogue.

  8. Nonlinear evolution of f(R) cosmologies. I. Methodology

    International Nuclear Information System (INIS)

    Oyaizu, Hiroaki

    2008-01-01

    We introduce the method and the implementation of a cosmological simulation of a class of metric-variation f(R) models that accelerate the cosmological expansion without a cosmological constant and evade solar-system bounds of small-field deviations to general relativity. Such simulations are shown to reduce to solving a nonlinear Poisson equation for the scalar degree of freedom introduced by the f(R) modifications. We detail the method to efficiently solve the nonlinear Poisson equation by using a Newton-Gauss-Seidel relaxation scheme coupled with the multigrid method to accelerate the convergence. The simulations are shown to satisfy tests comparing the simulated outcome to analytical solutions for simple situations, and the dynamics of the simulations are tested with orbital and Zeldovich collapse tests. Finally, we present several static and dynamical simulations using realistic cosmological parameters to highlight the differences between standard physics and f(R) physics. In general, we find that the f(R) modifications result in stronger gravitational attraction that enhances the dark matter power spectrum by ∼20% for large but observationally allowed f(R) modifications. A more detailed study of the nonlinear f(R) effects on the power spectrum are presented in a companion paper.

  9. Solar System constraints to general f(R) gravity

    International Nuclear Information System (INIS)

    Chiba, Takeshi; Smith, Tristan L.; Erickcek, Adrienne L.

    2007-01-01

    It has been proposed that cosmic acceleration or inflation can be driven by replacing the Einstein-Hilbert action of general relativity with a function f(R) of the Ricci scalar R. Such f(R) gravity theories have been shown to be equivalent to scalar-tensor theories of gravity that are incompatible with Solar System tests of general relativity, as long as the scalar field propagates over Solar System scales. Specifically, the parameterized post-Newtonian (PPN) parameter in the equivalent scalar-tensor theory is γ=1/2, which is far outside the range allowed by observations. In response to a flurry of papers that questioned the equivalence of f(R) theory to scalar-tensor theories, it was recently shown explicitly, without resorting to the scalar-tensor equivalence, that the vacuum field equations for 1/R gravity around a spherically symmetric mass also yield γ=1/2. Here we generalize this analysis to f(R) gravity and enumerate the conditions that, when satisfied by the function f(R), lead to the prediction that γ=1/2

  10. f(R) gravity and chameleon theories

    International Nuclear Information System (INIS)

    Brax, Philippe; Bruck, Carsten van de; Davis, Anne-Christine; Shaw, Douglas J.

    2008-01-01

    We analyze f(R) modifications of Einstein's gravity as dark energy models in the light of their connection with chameleon theories. Formulated as scalar-tensor theories, the f(R) theories imply the existence of a strong coupling of the scalar field to matter. This would violate all experimental gravitational tests on deviations from Newton's law. Fortunately, the existence of a matter dependent mass and a thin-shell effect allows one to alleviate these constraints. The thin-shell condition also implies strong restrictions on the cosmological dynamics of the f(R) theories. As a consequence, we find that the equation of state of dark energy is constrained to be extremely close to -1 in the recent past. We also examine the potential effects of f(R) theories in the context of the Eoet-wash experiments. We show that the requirement of a thin shell for the test bodies is not enough to guarantee a null result on deviations from Newton's law. As long as dark energy accounts for a sizeable fraction of the total energy density of the Universe, the constraints that we deduce also forbid any measurable deviation of the dark energy equation of state from -1. All in all, we find that both cosmological and laboratory tests imply that f(R) models are almost coincident with a ΛCDM model at the background level.

  11. Stellar equilibrium configurations of white dwarfs in the f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, G.A.; Moraes, P.H.R.S.; Marinho, R.M.; Malheiro, M. [Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, SP (Brazil); Lobato, R.V. [Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, SP (Brazil); Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); ICRANet, Pescara (Italy); Arbanil, Jose D.V. [Universidad Privada del Norte, Departamento de Ciencias, Lima (Peru); Otoniel, E. [Universidade Federal do Cariri, Instituto de Formacao de Professores, Brejo Santo, CE (Brazil)

    2017-12-15

    In this work we investigate the equilibrium configurations of white dwarfs in a modified gravity theory, namely, f(R, T) gravity, for which R and T stand for the Ricci scalar and trace of the energy-momentum tensor, respectively. Considering the functional form f(R, T) = R+2λT, with λ being a constant, we obtain the hydrostatic equilibrium equation for the theory. Some physical properties of white dwarfs, such as: mass, radius, pressure and energy density, as well as their dependence on the parameter λ are derived. More massive and larger white dwarfs are found for negative values of λ when it decreases. The equilibrium configurations predict a maximum mass limit for white dwarfs slightly above the Chandrasekhar limit, with larger radii and lower central densities when compared to standard gravity outcomes. The most important effect of f(R, T) theory for massive white dwarfs is the increase of the radius in comparison with GR and also f(R) results. By comparing our results with some observational data of massive white dwarfs we also find a lower limit for λ, namely, λ > -3 x 10{sup -4}. (orig.)

  12. Dynamics of anisotropic power-law f(R) cosmology

    International Nuclear Information System (INIS)

    Shamir, M. F.

    2016-01-01

    Modified theories of gravity have attracted much attention of the researchers in the recent years. In particular, the f(R) theory has been investigated extensively due to important f(R) gravity models in cosmological contexts. This paper is devoted to exploring an anisotropic universe in metric f(R) gravity. A locally rotationally symmetric Bianchi type I cosmological model is considered for this purpose. Exact solutions of modified field equations are obtained for a well-known f(R) gravity model. The energy conditions are also discussed for the model under consideration. The viability of the model is investigated via graphical analysis using the present-day values of cosmological parameters. The model satisfies null energy, weak energy, and dominant energy conditions for a particular range of the anisotropy parameter while the strong energy condition is violated, which shows that the anisotropic universe in f(R) gravity supports the crucial issue of accelerated expansion of the universe.

  13. Dynamics of anisotropic power-law f(R) cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M. F., E-mail: farasat.shamir@nu.edu.pk [National University of Computer and Emerging Sciences, Lahore Campus, Department of Sciences and Humanities (Pakistan)

    2016-12-15

    Modified theories of gravity have attracted much attention of the researchers in the recent years. In particular, the f(R) theory has been investigated extensively due to important f(R) gravity models in cosmological contexts. This paper is devoted to exploring an anisotropic universe in metric f(R) gravity. A locally rotationally symmetric Bianchi type I cosmological model is considered for this purpose. Exact solutions of modified field equations are obtained for a well-known f(R) gravity model. The energy conditions are also discussed for the model under consideration. The viability of the model is investigated via graphical analysis using the present-day values of cosmological parameters. The model satisfies null energy, weak energy, and dominant energy conditions for a particular range of the anisotropy parameter while the strong energy condition is violated, which shows that the anisotropic universe in f(R) gravity supports the crucial issue of accelerated expansion of the universe.

  14. Cosmology of f(R) gravity in the metric variational approach

    Science.gov (United States)

    Li, Baojiu; Barrow, John D.

    2007-04-01

    We consider the cosmologies that arise in a subclass of f(R) gravity with f(R)=R+μ2n+2/(-R)n and n∈(-1,0) in the metric (as opposed to the Palatini) variational approach to deriving the gravitational field equations. The calculations of the isotropic and homogeneous cosmological models are undertaken in the Jordan frame and at both the background and the perturbation levels. For the former, we also discuss the connection to the Einstein frame in which the extra degree of freedom in the theory is associated with a scalar field sharing some of the properties of a “chameleon” field. For the latter, we derive the cosmological perturbation equations in general theories of f(R) gravity in covariant form and implement them numerically to calculate the cosmic microwave background (CMB) temperature and matter power spectra of the cosmological model. The CMB power is shown to reduce at low l’s, and the matter power spectrum is almost scale independent at small scales, thus having a similar shape to that in standard general relativity. These are in stark contrast with what was found in the Palatini f(R) gravity, where the CMB power is largely amplified at low l’s and the matter spectrum is strongly scale dependent at small scales. These features make the present model more adaptable than that arising from the Palatini f(R) field equations, and none of the data on background evolution, CMB power spectrum, or matter power spectrum currently rule it out.

  15. MR investigation of recurrent cholesteatomas

    International Nuclear Information System (INIS)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-01-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted [fr

  16. Further stable neutron star models from f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Astashenok, Artyom V. [I. Kant Baltic Federal University, Institute of Physics and Technology, Nevskogo st. 14, Kaliningrad, 236041 (Russian Federation); Capozziello, Salvatore [Dipartimento di Fisica, Università di Napoli ' ' Federico II' ' , Via Cinthia, 9, Napoli, I–80126 (Italy); Odintsov, Sergei D., E-mail: artyom.art@gmail.com, E-mail: capozziello@na.infn.it, E-mail: odintsov@ieec.uab.es [Instituciò Catalana de Recerca i Estudis Avançats (ICREA), Barcelona (Spain)

    2013-12-01

    Neutron star models in perturbative f(R) gravity are considered with realistic equations of state. In particular, we consider the FPS, SLy and other equations of state and a case of piecewise equation of state for stars with quark cores. The mass-radius relations for f(R) = R+R(e{sup −R/R{sub 0}}−1) model and for R{sup 2} models with logarithmic and cubic corrections are obtained. In the case of R{sup 2} gravity with cubic corrections, we obtain that at high central densities (ρ > 10ρ{sub ns}, where ρ{sub ns} = 2.7 × 10{sup 14} g/cm{sup 3} is the nuclear saturation density), stable star configurations exist. The minimal radius of such stars is close to 9 km with maximal mass ∼ 1.9M{sub ⊙} (SLy equation). A similar situation takes place for AP4 and BSK20 EoS. Such an effect can give rise to more compact stars than in General Relativity. If observationally identified, such objects could constitute a formidable signature for modified gravity at astrophysical level. Another interesting result can be achieved in modified gravity with only a cubic correction. For some EoS, the upper limit of neutron star mass increases and therefore these EoS can describe realistic star configurations (although, in General Relativity, these EoS are excluded by observational constraints)

  17. Further stable neutron star models from f(R) gravity

    International Nuclear Information System (INIS)

    Astashenok, Artyom V.; Capozziello, Salvatore; Odintsov, Sergei D.

    2013-01-01

    Neutron star models in perturbative f(R) gravity are considered with realistic equations of state. In particular, we consider the FPS, SLy and other equations of state and a case of piecewise equation of state for stars with quark cores. The mass-radius relations for f(R) = R+R(e −R/R 0 −1) model and for R 2 models with logarithmic and cubic corrections are obtained. In the case of R 2 gravity with cubic corrections, we obtain that at high central densities (ρ > 10ρ ns , where ρ ns = 2.7 × 10 14 g/cm 3 is the nuclear saturation density), stable star configurations exist. The minimal radius of such stars is close to 9 km with maximal mass ∼ 1.9M ⊙ (SLy equation). A similar situation takes place for AP4 and BSK20 EoS. Such an effect can give rise to more compact stars than in General Relativity. If observationally identified, such objects could constitute a formidable signature for modified gravity at astrophysical level. Another interesting result can be achieved in modified gravity with only a cubic correction. For some EoS, the upper limit of neutron star mass increases and therefore these EoS can describe realistic star configurations (although, in General Relativity, these EoS are excluded by observational constraints)

  18. anti pp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.M. (Connecticut Univ., Storrs (USA). Dept. of Physics); Fearnley, T. (University Coll., London (UK). Dept. of Physics and Astronomy); Guillaud, J.P. (Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules)

    1984-06-21

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range ..sqrt..anti s approx.= (10/1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in anti pp and pp differential cross-sections. As energy increases beyond the ISR range (..sqrt..anti s = (23/62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between anti pp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of anti pp and pp differential cross-sections at future collider energies ..sqrt..s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the anti pp differential cross-section at the ISR and SPS collider in the vertical stroketvertical stroke-range (0.5/2.0) (GeV)/sup 2/ is stressed.

  19. Closed string tachyon driving f(R) cosmology

    Science.gov (United States)

    Wang, Peng; Wu, Houwen; Yang, Haitang

    2018-05-01

    To study quantum effects on the bulk tachyon dynamics, we replace R with f(R) in the low-energy effective action that couples gravity, the dilaton, and the bulk closed string tachyon of bosonic closed string theory and study properties of their classical solutions. The α' corrections of the graviton-dilaton-tachyon system are implemented in the f(R). We obtain the tachyon-induced rolling solutions and show that the string metric does not need to remain fixed in some cases. In the case with H( t=‑∞ ) = , only the R and R2 terms in f(R) play a role in obtaining the rolling solutions with nontrivial metric. The singular behavior of more classical solutions are investigated and found to be modified by quantum effects. In particular, there could exist some classical solutions, in which the tachyon field rolls down from a maximum of the tachyon potential while the dilaton expectation value is always bounded from above during the rolling process.

  20. f(R) gravity, torsion and non-metricity

    International Nuclear Information System (INIS)

    Sotiriou, Thomas P

    2009-01-01

    For both f(R) theories of gravity with an independent symmetric connection (no torsion), usually referred to as Palatini f(R) gravity theories, and for f(R) theories of gravity with torsion but no non-metricity, called U4 theories, it has been shown that the independent connection can actually be eliminated algebraically, as long as this connection does not couple to matter. Remarkably, the outcome in both cases is the same theory, which is dynamically equivalent with an ω 0 = -3/2 Brans-Dicke theory. It is shown here that even for the most general case of an independent connection with both non-metricity and torsion, one arrives at exactly the same theory as in the more restricted cases. This generalizes the previous results and explains why assuming that either the torsion or the non-metricity vanishing ultimately leads to the same theory. It also demonstrates that f(R) actions cannot support an independent connection which carries dynamical degrees of freedom, irrespective of how general this connection is, at least as long as there is no connection-matter coupling. (fast track communication)

  1. Solcellsparkeringen : En jämförande fallstudie för elbilar och bensinbilar

    OpenAIRE

    Myrén Andersson, Isac; Yttermyr-Sütt, Frans

    2017-01-01

    Av Sveriges totala växthusgasutsläpp är det i nuläget transportsektorn som stårr den största andelen och stårr mer än 30 % av alla utsläpp. Med ett ökande fordonsbestånd och ett fortsatt behov av transporter blir lösningar som minskar utsläppen från denna sektor avgörande för Sveriges hållbara utveckling. Eftersom 93 % av Sveriges drygt 4,7 miljoner personbilar drivs av fossila bränslen skulle investeringar i alternativa färdmedel såsom elbilar kunna leda Sverige i rätt riktning. Förfat...

  2. Standard cosmological evolution in the f(R) model to Kaluza-Klein cosmology

    International Nuclear Information System (INIS)

    Aghmohammadi, A; Abolhassani, M R; Saaidi, Kh; Vajdi, A

    2009-01-01

    In this paper, using f(R) theory of gravity we explicitly calculate cosmological evolution in the presence of a perfect fluid source in four- and five-dimensional space-time in which this cosmological evolution in self-creation is presented by Reddy et al (2009 Int. J. Theor. Phys. 48 10). An exact cosmological model is presented using a relation between Einstein's gravity field equation components due to a metric with the same component from f(R) theory of gravity. Some physics and kinematical properties of the model are also discussed.

  3. Peer-Reviewed Research and the IEP: Implications of "Ridley School District v. M.R. and J.R. ex rel. E.R." (2012)

    Science.gov (United States)

    Yell, Mitchell L.; Katsiyannis, Antonis; Losinski, Mickey; Marshall, Kelsey

    2016-01-01

    This article examines a case out of the U.S. Court of Appeals for the Third Circuit: "Ridley School District v. M.R and J.R. ex rel. E.R." (2012). The case is the first circuit court case in which the Individuals with Disabilities Education Improvement Act requirement that special education services be based on peer-reviewed research…

  4. Effective Dark Matter Halo Catalog in f(R) Gravity.

    Science.gov (United States)

    He, Jian-Hua; Hawken, Adam J; Li, Baojiu; Guzzo, Luigi

    2015-08-14

    We introduce the idea of an effective dark matter halo catalog in f(R) gravity, which is built using the effective density field. Using a suite of high resolution N-body simulations, we find that the dynamical properties of halos, such as the distribution of density, velocity dispersion, specific angular momentum and spin, in the effective catalog of f(R) gravity closely mimic those in the cold dark matter model with a cosmological constant (ΛCDM). Thus, when using effective halos, an f(R) model can be viewed as a ΛCDM model. This effective catalog therefore provides a convenient way for studying the baryonic physics, the galaxy halo occupation distribution and even semianalytical galaxy formation in f(R) cosmologies.

  5. Constraints on perturbative f(R) gravity via neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Arapoğlu, Savaş; Ekşi, K. Yavuz [İstanbul Technical University, Faculty of Science and Letters, Physics Engineering Department, Maslak 34469, İstanbul (Turkey); Deliduman, Cemsinan, E-mail: arapoglu@itu.edu.tr, E-mail: cemsinan@msgsu.edu.tr, E-mail: eksi@itu.edu.tr [Mimar Sinan Fine Arts University, Department of Physics, Beşiktaş 34349, İstanbul (Turkey)

    2011-07-01

    We study the structure of neutron stars in perturbative f(R) gravity models with realistic equations of state. We obtain mass-radius relations in a gravity model of the form f(R) = R+αR{sup 2}. We find that deviations from the results of general relativity, comparable to the variations due to using different equations of state (EoS'), are induced for |α| ∼ 10{sup 9} cm{sup 2}. Some of the soft EoS' that are excluded within the framework of general relativity can be reconciled with the 2 solar mass neutron star recently observed for certain values of α within this range. For some of the EoS' we find that a new solution branch, which allows highly massive neutron stars, exists for values of α greater than a few 10{sup 9} cm{sup 2}. We find constraints on α for a variety of EoS' using the recent observational constraints on the mass-radius relation. These are all 5 orders of magnitude smaller than the recent constraint obtained via Gravity Probe B for this gravity model. The associated length scale √(alpha)approx 10{sup 5} cm is only an order of magnitude smaller than the typical radius of a neutron star, the probe used in this test. This implies that real deviations from general relativity can be even smaller.

  6. Wormholes in R{sup 2}-gravity within the f(R, T) formalism

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, P.K.; Sahoo, Parbati [Birla Institute of Technology and Science-Pilani, Department of Mathematics, Hyderabad (India); Moraes, P.H.R.S. [ITA-Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, Sao Paulo (Brazil)

    2018-01-15

    We propose, as a novelty in the literature, the modeling of wormholes within a particular case of f(R, T) gravity, namely f(R, T) = R + αR{sup 2} + λT, with R and T being the Ricci scalar and trace of the energy-momentum tensor, respectively, while α and λ are constants. Although such a functional form application can be found in the literature, those concern compact astrophysical objects, such that no wormhole analysis has been done so far. The quadratic geometric and linear material corrections of this theory render the matter content of the wormhole remarkably able to obey the energy conditions. (orig.)

  7. Existence of relativistic stars in f(R) gravity

    International Nuclear Information System (INIS)

    Upadhye, Amol; Hu, Wayne

    2009-01-01

    We refute recent claims in the literature that stars with relativistically deep potentials cannot exist in f(R) gravity. Numerical examples of stable stars, including relativistic (GM * /r * ∼0.1), constant density stars, are studied. As a star is made larger, nonlinear 'chameleon' effects screen much of the star's mass, stabilizing gravity at the stellar center. Furthermore, we show that the onset of this chameleon screening is unrelated to strong gravity. At large central pressures P>ρ/3, f(R) gravity, like general relativity, does have a maximum gravitational potential, but at a slightly smaller value: GM * /r * | max =0.345<4/9 for constant density and one choice of parameters. This difference is associated with negative central curvature R under general relativity not being accessed in the f(R) model, but does not apply to any known astrophysical object.

  8. pp32 (ANP32A expression inhibits pancreatic cancer cell growth and induces gemcitabine resistance by disrupting HuR binding to mRNAs.

    Directory of Open Access Journals (Sweden)

    Timothy K Williams

    Full Text Available The expression of protein phosphatase 32 (PP32, ANP32A is low in poorly differentiated pancreatic cancers and is linked to the levels of HuR (ELAV1, a predictive marker for gemcitabine response. In pancreatic cancer cells, exogenous overexpression of pp32 inhibited cell growth, supporting its long-recognized role as a tumor suppressor in pancreatic cancer. In chemotherapeutic sensitivity screening assays, cells overexpressing pp32 were selectively resistant to the nucleoside analogs gemcitabine and cytarabine (ARA-C, but were sensitized to 5-fluorouracil; conversely, silencing pp32 in pancreatic cancer cells enhanced gemcitabine sensitivity. The cytoplasmic levels of pp32 increased after cancer cells are treated with certain stressors, including gemcitabine. pp32 overexpression reduced the association of HuR with the mRNA encoding the gemcitabine-metabolizing enzyme deoxycytidine kinase (dCK, causing a significant reduction in dCK protein levels. Similarly, ectopic pp32 expression caused a reduction in HuR binding of mRNAs encoding tumor-promoting proteins (e.g., VEGF and HuR, while silencing pp32 dramatically enhanced the binding of these mRNA targets. Low pp32 nuclear expression correlated with high-grade tumors and the presence of lymph node metastasis, as compared to patients' tumors with high nuclear pp32 expression. Although pp32 expression levels did not enhance the predictive power of cytoplasmic HuR status, nuclear pp32 levels and cytoplasmic HuR levels associated significantly in patient samples. Thus, we provide novel evidence that the tumor suppressor function of pp32 can be attributed to its ability to disrupt HuR binding to target mRNAs encoding key proteins for cancer cell survival and drug efficacy.

  9. f(R) gravity: scalar perturbations in the late Universe

    Czech Academy of Sciences Publication Activity Database

    Eingorn, M.; Novák, Jan; Zhuk, A.

    2014-01-01

    Roč. 74, č. 8 (2014), s. 3005 ISSN 1434-6044 Institutional support: RVO:67985840 Keywords : nonlinear f(R) gravity * scalar cosmological perturbations * scalaron Subject RIV: BA - General Mathematics Impact factor: 5.084, year: 2014 http://link.springer.com/article/10.1140/epjc/s10052-014-3005-1

  10. Models of f(R) cosmic acceleration that evade solar system tests

    International Nuclear Information System (INIS)

    Hu, Wayne; Sawicki, Ignacy

    2007-01-01

    We study a class of metric-variation f(R) models that accelerates the expansion without a cosmological constant and satisfies both cosmological and solar-system tests in the small-field limit of the parameter space. Solar-system tests alone place only weak bounds on these models, since the additional scalar degree of freedom is locked to the high-curvature general-relativistic prediction across more than 25 orders of magnitude in density, out through the solar corona. This agreement requires that the galactic halo be of sufficient extent to maintain the galaxy at high curvature in the presence of the low-curvature cosmological background. If the galactic halo and local environment in f(R) models do not have substantially deeper potentials than expected in ΛCDM, then cosmological field amplitudes |f R | > or approx.10 -6 will cause the galactic interior to evolve to low curvature during the acceleration epoch. Viability of large-deviation models therefore rests on the structure and evolution of the galactic halo, requiring cosmological simulations of f(R) models, and not directly on solar-system tests. Even small deviations that conservatively satisfy both galactic and solar-system constraints can still be tested by future, percent-level measurements of the linear power spectrum, while they remain undetectable to cosmological-distance measures. Although we illustrate these effects in a specific class of models, the requirements on f(R) are phrased in a nearly model-independent manner

  11. Invariant-mass distributions for the pp{yields}pp{eta} reaction at Q=10 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Moskal, P.; Czerwinski, E.; Klaja, J.; Klaja, P.; Krzemien, W. [Jagellonian University, Institute of Physics, Cracow (Poland); Research Center Juelich, Nuclear Physics Institute, Juelich (Germany); Czyzykiewicz, R. [Jagellonian University, Institute of Physics, Cracow (Poland); University of Silesia, Institute of Physics, Katowice (Poland); Gil, D.; Jarczyk, L.; Kamys, B.; Silarski, M.; Smyrski, J.; Zdebik, J.; Zielinski, M.J. [Jagellonian University, Institute of Physics, Cracow (Poland); Grzonka, D.; Oelert, W.; Ritman, J.; Sefzick, T.; Wuestner, P. [Research Center Juelich, Nuclear Physics Institute, Juelich (Germany); Khoukaz, A.; Taeschner, A.; Zipper, W. [Westfaelische Wilhelms-Universitaet, IKP, Muenster (Germany); Siemaszko, M. [University of Silesia, Institute of Physics, Katowice (Poland); Wolke, M. [SE-751 05 Uppsala University, Department of Physics and Astronomy, Uppsala (Sweden)

    2010-02-15

    Proton-proton and proton-{eta} invariant-mass distributions and the total cross-section for the pp{yields}pp{eta} reaction have been determined near the threshold at an excess energy of Q=10 MeV. The experiment has been conducted using the COSY-11 detector setup and the cooler synchrotron COSY. The determined invariant-mass spectra reveal significant enhancements in the region of low proton-proton relative momenta, similarly as observed previously at higher excess energies of Q=15.5 MeV and Q=40 MeV. (orig.)

  12. f(R) gravity cosmology in scalar degree of freedom

    International Nuclear Information System (INIS)

    Goswami, Umananda Dev; Deka, Kabita

    2014-01-01

    The models of f(R) gravity belong to an important class of modified gravity models where the late time cosmic accelerated expansion is considered as the manifestation of the large scale modification of the force of gravity. f(R) gravity models can be expressed in terms of a scalar degree of freedom by explicit redefinition of model's variable. Here we report about the study of the features of cosmological parameters and hence the cosmological evolution using the scalar degree of freedom of the f(R) = ξR n gravity model in the Friedmann-Lemaître-Robertson-Walker (FLRW) background

  13. Constraint propagation equations of the 3+1 decomposition of f(R) gravity

    International Nuclear Information System (INIS)

    Paschalidis, Vasileios; Shapiro, Stuart L; Halataei, Seyyed M H; Sawicki, Ignacy

    2011-01-01

    Theories of gravity other than general relativity (GR) can explain the observed cosmic acceleration without a cosmological constant. One such class of theories of gravity is f(R). Metric f(R) theories have been proven to be equivalent to Brans-Dicke (BD) scalar-tensor gravity without a kinetic term (ω = 0). Using this equivalence and a 3+1 decomposition of the theory, it has been shown that metric f(R) gravity admits a well-posed initial value problem. However, it has not been proven that the 3+1 evolution equations of metric f(R) gravity preserve the (Hamiltonian and momentum) constraints. In this paper, we show that this is indeed the case. In addition, we show that the mathematical form of the constraint propagation equations in BD-equilavent f(R) gravity and in f(R) gravity in both the Jordan and Einstein frames is exactly the same as in the standard ADM 3+1 decomposition of GR. Finally, we point out that current numerical relativity codes can incorporate the 3+1 evolution equations of metric f(R) gravity by modifying the stress-energy tensor and adding an additional scalar field evolution equation. We hope that this work will serve as a starting point for relativists to develop fully dynamical codes for valid f(R) models.

  14. Dynamic MR-mammography in invasive lobular breast cancer; Dynamische MR-Mammographie beim invasiv lobulaeren Mammakarzinom bei 1,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sittek, H.; Perlet, C.; Kessler, M.; Reiser, M. [Institut fuer Radiologische Diagnostik, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany); Untch, M. [Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany)

    1998-12-31

    Material and Methods: We carried out 1505 MR mammographoes in 1357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement, and type 3 with diffuse contrast enhancement of the glandular body. Results: Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. (orig.) [Deutsch] Material und Methode: Im Zeitraum 05/1993 bis 06/1996 fuehrten wir bei 1357 Patientinnen 1505 MR-Mammographien durch. In 413 Faellen wurde eine Probeexzision indiziert. Die histologische Untersuchung ergab in 214 Faellen einen malignen Tumor. Darunter befanden sich 23 ILC. Die MR-M wurden an einem 1,0 T MRT-System (Impact, Siemens, Erlangen) mit einer dynamischen FLASH 3D Sequenz durchgefuehrt. Neben dem prozentualen Anstieg der Signalintensitaet innerhalb einer Laesion haben wir fuer die Diagnostik folgende morphologische Befundmuster (BM) unterschieden: Typ 1: Keine Aufnahme, Typ 2: Fokale Aufnahme, Typ 3: Diffuse Aufnahme des Druesenkoerpers in der MR-M. Ergebnisse: Mit der MR-M konnten 19/23 (82,6%) der ILC anhand einer fokalen Zunahme der Signalintensitaet richtig positiv erkannt werden (BM Typ 2). Vier der ILC waren in der MR-M falsch negativ. In zwei Faellen (2/23) war keine Zunahme der Signalintensitaet zu verzeichnen (BM Typ 1). In zwei weiteren Faellen (2/23) maskierte eine diffuse Signalintensitaetszunahme des Druesenkoerpers (BM Typ 3

  15. Robust approach to f(R) gravity

    International Nuclear Information System (INIS)

    Jaime, Luisa G.; Patino, Leonardo; Salgado, Marcelo

    2011-01-01

    We consider metric f(R) theories of gravity without mapping them to their scalar-tensor counterpart, but using the Ricci scalar itself as an ''extra'' degree of freedom. This approach avoids then the introduction of a scalar-field potential that might be ill defined (not single valued). In order to explicitly show the usefulness of this method, we focus on static and spherically symmetric spacetimes and deal with the recent controversy about the existence of extended relativistic objects in certain class of f(R) models.

  16. Possible antigravity regions in F(R) theory?

    Energy Technology Data Exchange (ETDEWEB)

    Bamba, Kazuharu, E-mail: bamba@kmi.nagoya-u.ac.jp [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Nojiri, Shin' ichi, E-mail: nojiri@phys.nagoya-u.ac.jp [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Odintsov, Sergei D., E-mail: odintsov@ieec.uab.es [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Instituciò Catalana de Recerca i Estudis Avançats (ICREA), Barcelona (Spain); Institut de Ciencies de l' Espai (CSIC-IEEC), Campus UAB, Facultat de Ciencies, Torre C5-Par-2a pl, E-08193 Bellaterra (Barcelona) (Spain); Tomsk State Pedagogical University, Kievskaya Avenue, 60, 634061, Tomsk (Russian Federation); Sáez-Gómez, Diego, E-mail: diego.saezgomez@uct.ac.za [Astrophysics, Cosmology and Gravity Centre (ACGC) and Department of Mathematics and Applied Mathematics, University of Cape Town, Rondebosch 7701, Cape Town (South Africa); Fisika Teorikoaren eta Zientziaren Historia Saila, Zientzia eta Teknologia Fakultatea, Euskal Herriko Unibertsitatea, 644 Posta Kutxatila, 48080 Bilbao (Spain)

    2014-03-07

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  17. Holographic dark energy and f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Aghamohammadi, A [Faculty of Science, Islamic Azad University of Sanandaj, Sanandaj (Iran, Islamic Republic of); Saaidi, Kh, E-mail: ksaaidi@uok.ac.ir, E-mail: agha35484@yahoo.com [Department of Physics, Faculty of Science, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2011-02-15

    We investigate the corresponding relation between f(R) gravity and holographic dark energy. We introduce a type of energy density from f(R) that has the same role as holographic dark energy. We obtain the differential equation that specifies the evolution of the introduced energy density parameter based on a varying gravitational constant. We discover the relation for the equation of state parameter for low redshifts that contains varying G correction.

  18. Possible antigravity regions in F(R) theory?

    Science.gov (United States)

    Bamba, Kazuharu; Nojiri, Shin'ichi; Odintsov, Sergei D.; Sáez-Gómez, Diego

    2014-03-01

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  19. Possible antigravity regions in F(R) theory?

    International Nuclear Information System (INIS)

    Bamba, Kazuharu; Nojiri, Shin'ichi; Odintsov, Sergei D.; Sáez-Gómez, Diego

    2014-01-01

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  20. f(R) constant-roll inflation

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, Hayato [Universidad de Valencia-CSIC, Instituto de Fisica Corpuscular (IFIC), Valencia (Spain); Starobinsky, Alexei A. [L.D. Landau Institute for Theoretical Physics, RAS, Moscow (Russian Federation); National Research University Higher School of Economics, Moscow (Russian Federation)

    2017-08-15

    The previously introduced class of two-parametric phenomenological inflationary models in general relativity in which the slow-roll assumption is replaced by the more general, constant-roll condition is generalized to the case of f(R) gravity. A simple constant-roll condition is defined in the original Jordan frame, and exact expressions for a scalaron potential in the Einstein frame, for a function f(R) (in the parametric form) and for inflationary dynamics are obtained. The region of the model parameters permitted by the latest observational constraints on the scalar spectral index and the tensor-to-scalar ratio of primordial metric perturbations generated during inflation is determined. (orig.)

  1. P R Sengupta

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. P R Sengupta. Articles written in Sadhana. Volume 26 Issue 4 August 2001 pp 363-370. Surface waves in fibre-reinforced anisotropic elastic media · P R Sengupta Sisir Nath · More Details Abstract Fulltext PDF. The aim of this paper is to investigate surface waves in anisotropic fibre-reinforced ...

  2. Valuation of dynamic MR imaging for diagnosis of pituitary microadenomas

    International Nuclear Information System (INIS)

    Lu Wu; Zhou Shengli; Liu Yusheng

    2003-01-01

    Objective: To evaluate the use of keyhole dynamic magnetic resonance (MR) imaging in evaluation of pituitary microadenomas. Methods: Fifty-three patients with pituitary microadenomas proved by operation or clinical findings such as headache, amenorrhea, lactating, fat or acromegaly were retrospectively studied on dynamic MR, conventional contrast enhanced MR, and unenhanced MR. Then the image data were analyzed by two experienced doctors who didn't know the details and three degrees were made as follows: grade 0, no evidence of the tumor; grade I, asymmetry signals in the pituitary; and grade II, nodulated or sheets signals in the pituitary. The grading data were compared with statistical methods. Results: In dynamic MR grading system: grade 0 was revealed in 1 patient, grade I in 29 patients and grade II in 23 patients. In conventional enhanced MR: grade 0 in 26 patients, grade I in 17 patients and grade II in 10 patients. In conventional unenhanced MR: grade 0 in 39 patients, grade I in 10 patients and grade II in 4 patients. The diagnostic rate of dynamic MR, conventional enhanced MR, and unenhanced MR was 98.1%, 51.9%, and 26.4%, respectively. (P < 0.005). Dynamic MR can increase the grade of tumor compared to the other two, which is significant statistically. Conclusion: Keyhole dynamic MR can increase the diagnostic accuracy of pituitary microadenomas while decreasing the uncertainty. So dynamic MR should become a routine examination for pituitary microadenoma when suspected by clinical findings but negative in conventional MR

  3. 77 FR 1656 - Proposed Establishment of Restricted Areas R-5402, R-5403A, R-5403B, R-5403C, R-5403D, R-5403E, R...

    Science.gov (United States)

    2012-01-11

    ...-0117; Airspace Docket No. 09-AGL-31] RIN 2120-AI92 Proposed Establishment of Restricted Areas R-5402, R-5403A, R- 5403B, R-5403C, R-5403D, R-5403E, R-5403F; Devils Lake, ND AGENCY: Federal Aviation... Restricted Areas R-5402, R-5403A, R-5403B, R- 5403C, R-5403D, R-5403E, R-5403F; Devils Lake, ND (76 FR 72869...

  4. 48 CFR 53.301-26 - Award/Contract.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Award/Contract. 53.301-26 Section 53.301-26 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS Illustrations of Forms 53.301-26 Award/Contract. ER22AP08.000 [73 FR 21785, Apr...

  5. R Jayaraman

    Indian Academy of Sciences (India)

    More Details Fulltext PDF. Volume 13 Issue 10 October 2008 pp 898-908 General Article. Seymour Benzer and T4 rII - Running the Map into the Ground · R Jayaraman · More Details Fulltext PDF. Volume 15 Issue 12 December 2010 pp 1084-1096 General Article. Jacques Monod and the Advent of the Age of Operons.

  6. Stellar configurations in f(R) theories of gravity

    International Nuclear Information System (INIS)

    Henttunen, K.; Multamaeki, T.; Vilja, I.

    2008-01-01

    We study stellar configurations and the space-time around them in metric f(R) theories of gravity. In particular, we focus on the polytropic model of the Sun in two specific cases: the f(R)=R-μ 4 /R model and a model with a stabilizing higher order term f(R)=R-μ 4 /R+βR 3 /(3μ 4 ). We show how the stellar configuration in the f(R) theory can, by appropriate initial conditions, be selected to be equal to that described by the Lane-Emden equation and how a simple scaling relation exists between the solutions. We also derive the correct solution analytically near the center of the star in f(R) theory. Previous analytical and numerical results are confirmed, indicating that the space-time around the Sun is incompatible with solar system constraints in the f(R)=R-μ 4 /R model. Numerical work shows that stellar configurations, with a regular metric at the center, lead to γ PPN ≅1/2 outside the star for both models, i.e., the Schwarzschild-de Sitter space-time is not the correct vacuum solution for such configurations. This shows that even when one fine-tunes the initial conditions inside a star such that the mass of the effective scalar in the equivalent scalar-tensor theory is large, γ PPN is still 1/2 outside the star. Conversely, by selecting the Schwarzschild-de Sitter metric as the outside solution, or equivalently setting the mass of the effective scalar to be large outside the star, we find that the stellar configuration is unchanged but the metric is irregular at the center. The possibility of constructing a f(R) theory compatible with the solar system experiments and possible new constraints arising from the radius-mass relation of stellar objects is discussed

  7. Cosmological reconstruction of realistic modified F(R) gravities

    International Nuclear Information System (INIS)

    Nojiri, Shin'ichi; Odintsov, Sergei D.; Saez-Gomez, Diego

    2009-01-01

    The cosmological reconstruction scheme for modified F(R) gravity is developed in terms of e-folding (or, redshift). It is demonstrated how any FRW cosmology may emerge from specific F(R) theory. The specific examples of well-known cosmological evolution are reconstructed, including ΛCDM cosmology, deceleration with transition to phantom superacceleration era which may develop singularity or be transient. The application of this scheme to viable F(R) gravities unifying inflation with dark energy era is proposed. The additional reconstruction of such models leads to non-leading gravitational correction mainly relevant at the early/late universe and helping to pass the cosmological bounds (if necessary). It is also shown how cosmological reconstruction scheme may be generalized in the presence of scalar field.

  8. Cosmology of Horava-Lifshitz f(R) gravity

    International Nuclear Information System (INIS)

    Chakrabarti, Sayan K.; Sen, Anjan A.

    2011-08-01

    We discuss the cosmology of recently proposed Horava-Lifshitz f(R) gravity. In particular, we derive the modified Hubble equation that reduces to the standard HL gravity case in appropriate limit. We show how the bounce solutions in this theory are modified due to nonlinear effect of f(R) gravity. In addition we find that the solutions exist when the Universe can make turn around for large scale-factor. Therefore, in principle, the Universe in this set-up can show cyclic behavior. (orig.)

  9. Cosmology of Horava-Lifshitz f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Chakrabarti, Sayan K. [Univ. Tecnica de Lisboa (Portugal). Inst. Superior Tecnico; Dutta, Koushik [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Sen, Anjan A. [Centre of Theoretical Physics, Jamia Millia Islamia, New Dehli (India)

    2011-08-15

    We discuss the cosmology of recently proposed Horava-Lifshitz f(R) gravity. In particular, we derive the modified Hubble equation that reduces to the standard HL gravity case in appropriate limit. We show how the bounce solutions in this theory are modified due to nonlinear effect of f(R) gravity. In addition we find that the solutions exist when the Universe can make turn around for large scale-factor. Therefore, in principle, the Universe in this set-up can show cyclic behavior. (orig.)

  10. Galaxy-galaxy weak gravitational lensing in f(R) gravity

    Science.gov (United States)

    Li, Baojiu; Shirasaki, Masato

    2018-03-01

    We present an analysis of galaxy-galaxy weak gravitational lensing (GGL) in chameleon f(R) gravity - a leading candidate of non-standard gravity models. For the analysis, we have created mock galaxy catalogues based on dark matter haloes from two sets of numerical simulations, using a halo occupation distribution (HOD) prescription which allows a redshift dependence of galaxy number density. To make a fairer comparison between the f(R) and Λ cold dark matter (ΛCDM) models, their HOD parameters are tuned so that the galaxy two-point correlation functions in real space (and therefore the projected two-point correlation functions) match. While the f(R) model predicts an enhancement of the convergence power spectrum by up to ˜ 30 per cent compared to the standard ΛCDM model with the same parameters, the maximum enhancement of GGL is only half as large and less than 5 per cent on separations above ˜1-2 h-1 Mpc, because the latter is a cross-correlation of shear (or matter, which is more strongly affected by modified gravity) and galaxy (which is weakly affected given the good match between galaxy autocorrelations in the two models) fields. We also study the possibility of reconstructing the matter power spectrum by combination of GGL and galaxy clustering in f(R) gravity. We find that the galaxy-matter cross-correlation coefficient remains at unity down to ˜2-3 h-1 Mpc at relevant redshifts even in f(R) gravity, indicating joint analysis of GGL and galaxy clustering can be a powerful probe of matter density fluctuations in chameleon gravity. The scale dependence of the model differences in their predictions of GGL can potentially allows us to break the degeneracy between f(R) gravity and other cosmological parameters such as Ωm and σ8.

  11. CHCHD10 mutations p.R15L and p.G66V cause motoneuron disease by haploinsufficiency.

    Science.gov (United States)

    Brockmann, Sarah J; Freischmidt, Axel; Oeckl, Patrick; Müller, Kathrin; Ponna, Srinivas K; Helferich, Anika M; Paone, Christoph; Reinders, Jörg; Kojer, Kerstin; Orth, Michael; Jokela, Manu; Auranen, Mari; Udd, Bjarne; Hermann, Andreas; Danzer, Karin M; Lichtner, Peter; Walther, Paul; Ludolph, Albert C; Andersen, Peter M; Otto, Markus; Kursula, Petri; Just, Steffen; Weishaupt, Jochen H

    2018-02-15

    Mutations in the mitochondrially located protein CHCHD10 cause motoneuron disease by an unknown mechanism. In this study, we investigate the mutations p.R15L and p.G66V in comparison to wild-type CHCHD10 and the non-pathogenic variant p.P34S in vitro, in patient cells as well as in the vertebrate in vivo model zebrafish. We demonstrate a reduction of CHCHD10 protein levels in p.R15L and p.G66V mutant patient cells to approximately 50%. Quantitative real-time PCR revealed that expression of CHCHD10 p.R15L, but not of CHCHD10 p.G66V, is already abrogated at the mRNA level. Altered secondary structure and rapid protein degradation are observed with regard to the CHCHD10 p.G66V mutant. In contrast, no significant differences in expression, degradation rate or secondary structure of non-pathogenic CHCHD10 p.P34S are detected when compared with wild-type protein. Knockdown of CHCHD10 expression in zebrafish to about 50% causes motoneuron pathology, abnormal myofibrillar structure and motility deficits in vivo. Thus, our data show that the CHCHD10 mutations p.R15L and p.G66V cause motoneuron disease primarily based on haploinsufficiency of CHCHD10. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  13. Irradiation effect on PP/PMMA and PP/PP-g-PMMA matrices

    International Nuclear Information System (INIS)

    Marsongko; Soebianto, Yanti S.

    1998-01-01

    The effects of PMMA and PP-g-PMMA on the oxidation of polypropylene (PP) have been studied. The mixing was done in Laboplastomill at the temperature of 200 o C, and screw speed of 20 rpm, for 5 minutes. The PMMA concentrations were 1, 2, 5, and 10% by weight, and PP-g-PMMA (12% grafting) 5, 10, and 20% by weight. Mechanical properties (tensile strength (Tb) and elongation at break (Eb)( of the mixture decreased with the increase of PMMA content over 5%. The addition of PMMA over 3% produced non-transparent film. Electron beam irradiation at the dose of 5, 10, 30, and 50 kGy was carried out to accelerate the matrix oxidation is accelerated. The optimum properties of PP/PMMA blends can be achieved by addition of maximum 2% PMMA either direct as PMMA or as compatibilizer (PP-g-PMMA). (authors)

  14. Late-time cosmological approach in mimetic f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Baffou, E.H. [Institut de Mathematiques et de Sciences Physiques (IMSP), Porto-Novo (Benin); Houndjo, M.J.S. [Institut de Mathematiques et de Sciences Physiques (IMSP), Porto-Novo (Benin); Faculte des Sciences et Techniques de Natitingou, Natitingou (Benin); Hamani-Daouda, M. [Universite de Niamey, Departement de Physique, Niamey (Niger); Alvarenga, F.G. [Universidade Federal do Espirito Santo, Departamento de Engenharia e Ciencias Naturais, CEUNES, Sao Mateus, ES (Brazil)

    2017-10-15

    In this paper, we investigate the late-time cosmic acceleration in mimetic f(R, T) gravity with the Lagrange multiplier and potential in a Universe containing, besides radiation and dark energy, a self-interacting (collisional) matter. We obtain through the modified Friedmann equations the main equation that can describe the cosmological evolution. Then, with several models from Q(z) and the well-known particular model f(R, T), we perform an analysis of the late-time evolution. We examine the behavior of the Hubble parameter, the dark energy equation of state and the total effective equation of state and in each case we compare the resulting picture with the non-collisional matter (assumed as dust) and also with the collisional matter in mimetic f(R, T) gravity. The results obtained are in good agreement with the observational data and show that in the presence of the collisional matter the dark energy oscillations in mimetic f(R, T) gravity can be damped. (orig.)

  15. Generation of spherically symmetric metrics in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Amirabi, Z.; Halilsoy, M.; Mazharimousavi, S.H. [Eastern Mediterranean University, Department of Physics, Gazimagusa (Turkey)

    2016-06-15

    In D-dimensional spherically symmetric f(R) gravity there are three unknown functions to be determined from the fourth order differential equations. It is shown that the system remarkably may be integrated to relate two functions through the third one to provide a reduction to second order equations accompanied with a large class of potential solutions. The third function, which acts as the generator of the process, is F(R) = (df(R))/(dR). We recall that our generating function has been employed as a scalar field with an accompanying self-interacting potential previously, which is entirely different from our approach. Reduction of f(R) theory into a system of equations seems to be efficient enough to generate a solution corresponding to each generating function. As particular examples, besides the known ones, we obtain new black hole solutions in any dimension D. We further extend our analysis to cover non-zero energy-momentum tensors. Global monopole and Maxwell sources are given as examples. (orig.)

  16. Rational approximations of f(R) cosmography through Pad'e polynomials

    Science.gov (United States)

    Capozziello, Salvatore; D'Agostino, Rocco; Luongo, Orlando

    2018-05-01

    We consider high-redshift f(R) cosmography adopting the technique of polynomial reconstruction. In lieu of considering Taylor treatments, which turn out to be non-predictive as soon as z>1, we take into account the Pad&apose rational approximations which consist in performing expansions converging at high redshift domains. Particularly, our strategy is to reconstruct f(z) functions first, assuming the Ricci scalar to be invertible with respect to the redshift z. Having the so-obtained f(z) functions, we invert them and we easily obtain the corresponding f(R) terms. We minimize error propagation, assuming no errors upon redshift data. The treatment we follow naturally leads to evaluating curvature pressure, density and equation of state, characterizing the universe evolution at redshift much higher than standard cosmographic approaches. We therefore match these outcomes with small redshift constraints got by framing the f(R) cosmology through Taylor series around 0zsimeq . This gives rise to a calibration procedure with small redshift that enables the definitions of polynomial approximations up to zsimeq 10. Last but not least, we show discrepancies with the standard cosmological model which go towards an extension of the ΛCDM paradigm, indicating an effective dark energy term evolving in time. We finally describe the evolution of our effective dark energy term by means of basic techniques of data mining.

  17. F(R Gravity’s Rainbow and Its Einstein Counterpart

    Directory of Open Access Journals (Sweden)

    S. H. Hendi

    2016-01-01

    Full Text Available Motivated by UV completion of general relativity with a modification of a geometry at high energy scale, it is expected to have an energy dependent geometry. In this paper, we introduce charged black hole solutions with power Maxwell invariant source in the context of gravity’s rainbow. In addition, we investigate two classes of F(R gravity’s rainbow solutions. At first, we study energy dependent F(R gravity without energy-momentum tensor, and then we obtain F(R gravity’s rainbow in the presence of conformally invariant Maxwell source. We study geometrical properties of the mentioned solutions and compare their results. We also give some related comments regarding thermodynamical behavior of the obtained solutions and discuss thermal stability of the solutions.

  18. Exploring the liminality: properties of haloes and subhaloes in borderline f(R) gravity

    Science.gov (United States)

    Shi, Difu; Li, Baojiu; Han, Jiaxin; Gao, Liang; Hellwing, Wojciech A.

    2015-09-01

    We investigate the properties of dark matter haloes and subhaloes in an f(R) gravity model with |fR0| = 10-6, using a very-high-resolution N-body simulation. The model is a borderline between being cosmologically interesting and yet still consistent with current data. We find that the halo mass function in this model has a maximum 20 per cent enhancement compared with the Λ-cold-dark-matter (ΛCDM) predictions between z = 1 and 0. Because of the chameleon mechanism which screens the deviation from standard gravity in dense environments, haloes more massive than 1013 h-1 M⊙ in this f(R) model have very similar properties to haloes of similar mass in ΛCDM, while less massive haloes, such as that of the Milky Way, can have steeper inner density profiles and higher velocity dispersions due to their weaker screening. The halo concentration is remarkably enhanced for low-mass haloes in this model due to a deepening of the total gravitational potential. Contrary to the naive expectation, the halo formation time zf is later for low-mass haloes in this model, a consequence of these haloes growing faster than their counterparts in ΛCDM at late times and the definition of zf. Subhaloes, especially those less massive than 1011 h-1 M⊙, are substantially more abundant in this f(R) model for host haloes less massive than 1013 h-1 M⊙. We discuss the implications of these results for the Milky Way satellite abundance problem. Although the overall halo and subhalo properties in this borderline f(R) model are close to their ΛCDM predictions, our results suggest that studies of the Local Group and astrophysical systems, aided by high-resolution simulations, can be valuable for further tests of it.

  19. The holographic bound in the scalar-tensor and f(R) gravities

    International Nuclear Information System (INIS)

    Firouzjaee, J.T.

    2013-01-01

    The holographic bound has been extended to the different theory of gravities such as scalar-tensor gravity and f(R) gravity according to the Noether charge definition of the entropy for a black hole surface. We have introduced some popular examples of the flat FRW cosmology in order to investigate holographic bound in scalar-tensor and f(R) gravity. Using the holographic bound, we put an additional constraint on scalar-tensor gravity and the f(R) gravity parameters. We also discuss the transformation from Jordan frame to Einstein frame. (orig.)

  20. A preliminary study of murine walker-256 tumor hypoxia detected by blood oxygen level dependent-MR

    International Nuclear Information System (INIS)

    Zhang Shengjian; Mao Jian; Wu Bin; Peng Weijun

    2013-01-01

    Objective: To establish Walker-256 transplantation tumor model in SD Rats. To study of R_2"* signal changes on murine Walker-256 tumor after inhaling Carbogen by blood oxygen level dependent (BOLD)-MR, and to explore the feasibility of BOLD-MRI on detecting tumor hypoxia. Methods: Walker-256 tumor cell implanted subcutaneously in right lower abdomen of 95 female SD rats. MR was performed on the tumor-forming rats when the maximum diameter of tumor reached 1-3 cm, using a 3.0 T MR scanner equipped with a 3 inch animal surface coil. BOLD-MRI was done by using a multiecho SPGR sequence during inhaling air and at 10 minute after inhaling Carbogen, respectively. All images were transferred to GE ADW 4.3 workstation, then a baseline R_2"* (R_2"* a) and R_2"* (R_2"* b) after inhaling Carbogen of tumor was calculated using R_2 Star analysis software and ΔR_2"* was calculated through ΔR_2"* = R_2"* b -R_2"* a", meanwhile the volume of tumor were calculated as well. The difference of R_2"* signal pre and post-inhaling of Carbogen was compared with a paired t test, Pearson correlation was calculated between R_2"* a, ΔR_2"* and the volume of tumor, respectively. The correlation between ΔR_2"* and R_2"* a was also assessed by Pearson correlation. Results: Sixty-eight of ninety-five female SD rats formed the tumor (71.6%). The volume of tumor was from 352 to 13 173 mm"3. Mean ΔR_2"* decreased significantly (-2.26 ± 3.90) s"-"1 from (41.18 ± 22.29) s"-"1 during breathing air to (38.91 ± 21.35) s"-"1 10 min after inhaling Carbogen (t = 4.01, P 0.05). Conclusions: BOLD-MRI can detect the R_2"* signal change of murine Walker-256 tumor pre-and post-inhaling of Carbogen. The R_2"* signal showed significant decrease after inhaling Carbogen, however, the individual variation was remarkable. (authors)

  1. Pancreatic duct abnormalities in focal autoimmune pancreatitis: MR/MRCP imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Negrelli, Riccardo; Manfredi, Riccardo; Pedrinolla, Beatrice; Boninsegna, Enrico; Ventriglia, Anna; Mehrabi, Sara; Pozzi Mucelli, Roberto [G.B. Rossi University Hospital, University of Verona, Department of Radiology, Verona (Italy); Frulloni, Luca [Universita di Verona, Department of Gastroenterology, Policlinico G.B. Rossi, Verona (Italy)

    2014-08-09

    To evaluate the magnetic resonance (MR) imaging-MR cholangiopancreatographic (MRCP) findings of focal forms of autoimmune pancreatitis (AIP) to describe ductal involvement at diagnosis. MR examinations of 123 patients affected by AIP were analysed. We included 26 patients who satisfied International Consensus Diagnostic Criteria and were suffering from focal AIP. Image analysis included: site of parenchymal enlargement, main pancreatic duct (MPD) diameter, MPD stenosis, stricture length, presence of upstream dilation within the stricture, signal intensity, and pancreatic enhancement. Signal intensity abnormalities were localized in the head in 10/26 (38.5 %) and in the body-tail in 16/26 (61.5 %) patients. MRCP showed a single MPD stenosis in 12/26 (46.1 %) and multiple MPD stenosis in 14/26 (53.8 %) patients, without a dilation of the upstream MPD (mean: 3.83 mm). Lesions showed hypointensity on T1-weighted images in all patients, and hyperintensity on T2-weighted images in 22/26 (84.6 %) patients. The affected parenchyma was hypovascular during the arterial phase in 25/26 (96.2 %) patients with contrast retention. MR-MRCP are effective techniques for the diagnosis of AIP showing the loss of the physiological lobulation and the typical contrastographic appearance. The presence of multiple, long stenoses without an upstream MPD dilation at MRCP suggests the diagnosis of AIP, and can be useful in differential diagnosis of pancreatic adenocarcinoma. (orig.)

  2. Le developpement de Limacella glioderma (Fr.) R. Maire

    NARCIS (Netherlands)

    Reijnders, A.F.M.

    1979-01-01

    A comparison of the development of Limacella guttata (Fr.) Konrad & Maublanc with that of L. glioderma (Fr.) R. Maire shows clearly that the latter is of a more primitive type. This conclusion is based on the following observations: a. Limacella guttata has a pileocarpic development: the first

  3. Mr imaging and mr spectroscopy of brain metastases by mr perfusion

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Lichy, M.P.; Thilmann, C.; Guenther, M.; Bachert, P.; Delorme, S.; Schad, L.R.; Debus, J.; Schlemmer, H.P.; Maudsley, A.A.

    2003-01-01

    In follow-up examinations of irradiated brain metastases conventional contrast-enhanced morphological MR imaging is often unable to distinguish between transient radiation effects, radionecrosis, and tumor recurrence. To evaluate changes of relative cerebral blood flow (rCBF) in irradiated brain metastases arterial spin-labeling techniques (ASL) were applied and compared to the outcome of 1 H MR spectroscopy and spectroscopic imaging ( 1 H MRS, SI). Patients and methods In 2 patients follow-up examinations of irradiated brain metastases were performed on a 1.5-T tomograph (average single dose: 20 Gy/80% isodose). Relative CBF values of gray matter (GM), white matter (WM), and metastases (Met) were measured by means of the ASL techniques ITS-FAIR and Q2TIPS. 1 H MRS was performed with PRESS 1500/135. In both patients with initially hyperperfused metastases (Met/GM >1) the reduction of rCBF after stereotactic radiosurgery indicated response to treatment - even if the contrast-enhancing region increased - while increasing rCBF values indicated tumor progression. The findings were confirmed by 1 H MRS, SI and subsequent follow-up. The ASL techniques ITS-FAIR and Q2TIPS are able to monitor changes of rCBF in irradiated brain metastases. The two cases imply a possible role for ASL-MR perfusion imaging and 1 H MR spectroscopy in differentiating radiation effects from tumor progression. (orig.) [de

  4. Tissue- and environmental response-specific expression of 10 PP2C transcripts in Mesembryanthemum crystallinum.

    Science.gov (United States)

    Miyazaki, S; Koga, R; Bohnert, H J; Fukuhara, T

    1999-03-01

    Ten transcripts (Mpc1-10) homologous to protein phosphatases of the 2C family have been isolated from the halophyte Mesembryanthemum crystallinum (common ice plant). Transcripts range in size from 1.6 to 2.6 kb, and encode proteins whose catalytic domains are between 24% and 62% identical to that of the Arabidopsis PP2C, ABI1. Transcript expression is tissue specific. Two isoforms are present only in roots (Mpc1 and Mpc5), three in young leaves (Mpc6, 8 and 9), two in old leaves (Mpc6 and Mpc8), and two in post-flowering leaves (Mpc8 and Mpc9). Mpc2 is strongly expressed in roots and also in seeds, meristematic tissues and mature flowers. Mpc3 is specific for leaf meristems, and Mpc4 is found in root and leaf meristems. Mpc7 is restricted to meristematic tissues. Mpc10 is only present in mature flowers. Mpc2 (in roots and leaves), Mpc5 (in roots) and Mpc8 (weakly in leaves) are induced by salinity stress and drought conditions with different kinetics in different tissues, but other Mpcs are downregulated by stress. Cold stress (4 degrees C) leads to a decline in Mpc5 and Mp6, but low temperature provoked a long-term (days) increase in Mpc2 levels in leaves and a transient increase (less than 24 h) in roots. Four full-length transcripts have been obtained. In each case, after over-expression in E. coli, the isolated proteins exhibited (Mg2+-dependent, okadeic acid-insensitive) protein phosphatase activity, although activity against 32P-phosphocasein varied among different PP2Cs. Determination of tissue developmental and stress response specificity of PP2C will facilitate functional studies of signal-transducing enzymes in this halophytic organism.

  5. Indirect MR arthrography in the evaluation of tears of the glenoid labrum; Indirekte MR-Arthrographie in der Diagnostik von Laesionen des Labrum glenoidale

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Vahlensieck, M.; Lutterbey, G.; Pauleit, D.; Kreft, B.; Keller, E.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Wallny, T. [Orthopaedische Universitaetsklinik Bonn (Germany); Steuer, K.; Golombek, V. [Klinik fuer Unfallchirurgie, Univ. Bonn (Germany)

    1997-07-01

    Purpose: It has been shown that intravenous administration of contrast media produces an MR arthrographic effect without the need for intraarticular injection. This is the first study evaluating this new technique of indirect MR arthrography in the diagnosis of glenoid labrum tears. Methods: 28 patients with clinically suspected labral injuries were prospectively investigated (1.5 Tesla, flexible surface coil). A plain MR examination of the shoulder (transverse and oblique-coronal orientation, T{sub 1}-weighted spin- [T{sub E}/T{sub R} 15/675], proton density- and T{sub 2}*-weighted gradient echo [T{sub E}/T{sub R}/Flip 14,32/600/30 ] sequences) and indirect MR arthrography (transverse and oblique-coronal orientation, fat-suppressed T{sub 1}-weighted spin-echo sequences [T{sub E}/T{sub R} 15/675], intravenous injection of gadopentetate dimeglumine [0.1 mmol/kg], followed by 10-15 min of joint movement) were performed. Results were confirmed by arthroscopy and/or open surgery. Results: Indirect MR arthrography significantly improved delineation of the glenoid labrum and hyaline cartilage (p<0.05). Sensitivity and specificity of indirect MR arthrography in the diagnosis of labral injuries were 90% and 89%, compared to 79% and 67% of the native MR examination. Conclusion: Indirect MR arthrography is a promising non-invasive technique in the evaluation of the glenoid labrum. (orig.) [Deutsch] Ziel: In frueheren Studien wurde gezeigt, dass die intravenoese Injektion gadoliniumhaltiger Kontrastmittel zur Signalintensitaetssteigerung im Gelenkkavum fuehrt. In dieser Studie wurde erstmals diese Technik der indirekten MR-Arthrographie am Schultergelenk in der Diagnostik von Labrumlaesionen evaluiert. Methode: 28 Patienten mit klinischem Verdacht auf eine Verletzung des Labrum glenoidale und/oder der Rotatorenmanschette wurden prospektiv nach folgendem Protokoll an einem 1,5-Tesla-System mit einer Oberflaechen-Ringspule untersucht: 1. Native MR-Standard-Untersuchung mit

  6. Propagating Degrees of Freedom in f(R Gravity

    Directory of Open Access Journals (Sweden)

    Yun Soo Myung

    2016-01-01

    Full Text Available We have computed the number of polarization modes of gravitational waves propagating in the Minkowski background in f(R gravity. These are three of two from transverse-traceless tensor modes and one from a massive trace mode, which confirms the results found in the literature. There is no massless breathing mode and the massive trace mode corresponds to the Ricci scalar. A newly defined metric tensor in f(R gravity satisfies the transverse-traceless (TT condition as well as the TT wave equation.

  7. The coincidence problem in holographic f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Bisabr, Yousef, E-mail: y-bisabr@srttu.edu [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, Tehran 16788 (Iran, Islamic Republic of)

    2011-09-15

    It is well known that f(R) gravity models formulated in the Einstein conformal frame are equivalent to Einstein gravity together with a minimally coupled scalar field. In this case, the scalar field couples with the matter sector and the coupling term is given by the conformal factor. We apply the holographic principle to such interacting models. In a spatially flat universe, we show that the Einstein frame representation of f(R) models leads to a constant ratio of energy densities of dark matter to dark energy.

  8. Late-time cosmological evolution of a general class of f(R, T) gravity with minimal curvature-matter coupling

    Energy Technology Data Exchange (ETDEWEB)

    Shabani, Hamid [University of Sistan and Baluchestan, Physics Department, Faculty of Sciences, Zahedan (Iran, Islamic Republic of); Ziaie, Amir Hadi [Islamic Azad University, Department of Physics, Kahnooj Branch, Kerman (Iran, Islamic Republic of)

    2017-08-15

    In this work, we study the late-time cosmological solutions of f(R, T) = g(R) + h(-T) models assuming that the conservation of the energy-momentum tensor (EMT) is violated. We perform our analysis through constructing an autonomous dynamical system for the equations of motion. We study the stability properties of solutions via considering linear perturbations about the related equilibrium points. Moreover, we parameterize the Lagrangian by introducing the parameters m(r) and n(s). These parameters which are constructed out of the functions g(R) and h(-T) play the main role in finding the late-time behavior of the solutions. We find that there exist, in general, three classes of solutions; all models with n > 0 include a proper transition from a prolonged matter era to a de Sitter solution. Models with -0.5 < n < 0 and n{sup '} > 1, for at least a root of equation n(s) = s - 1, include an unphysical dark energy solution preceding an improper matter era. Finally, for n < -1/2 there is a transient accelerated expansion era with -1/2 < w{sup (eff)} < -1/3 before a de Sitter phase. For all cases, in order to have a long enough matter dominated epoch, the condition m{sup '} → 0{sup +} for r f(R, T) = R{sup β} + (-T){sup α} can be observationally motivating for m → 0{sup +} and -0.024 < α < 0.02 and therefore could provide a suitable setting for later investigations. (orig.)

  9. Distinguishing f(R) theories from general relativity by gravitational lensing effect

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongguang [Beijing Normal University, Department of Physics, Beijing (China); Aix Marseille Universite et Universite de Toulon, Centre de Physique Theorique (UMR 7332), Marseille (France); Wang, Xin; Li, Haida; Ma, Yongge [Beijing Normal University, Department of Physics, Beijing (China)

    2017-11-15

    The post-Newtonian formulation of a general class of f(R) theories is set up in a third-order approximation. It turns out that the information of a specific form of f(R) gravity is encoded in the Yukawa potential, which is contained in the perturbative expansion of the metric components. Although the Yukawa potential is canceled in the second-order expression of the effective refraction index of light, detailed analysis shows that the difference of the lensing effect between the f(R) gravity and general relativity does appear at the third order when √(f''(0)/f{sup '}(0)) is larger than the distance d{sub 0} to the gravitational source. However, the difference between these two kinds of theories will disappear in the axially symmetric spacetime region. Therefore only in very rare case the f(R) theories are distinguishable from general relativity by gravitational lensing effect in a third-order post-Newtonian approximation. (orig.)

  10. General proof of the entropy principle for self-gravitating fluid in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xiongjun [Department of Physics and Key Laboratory of Low Dimensional Quantum Structures andQuantum Control of Ministry of Education, Hunan Normal University,Changsha, Hunan 410081 (China); Guo, Minyong [Department of Physics, Beijing Normal University,Beijing 100875 (China); Jing, Jiliang [Department of Physics and Key Laboratory of Low Dimensional Quantum Structures andQuantum Control of Ministry of Education, Hunan Normal University,Changsha, Hunan 410081 (China)

    2016-08-29

    The discussions on the connection between gravity and thermodynamics attract much attention recently. We consider a static self-gravitating perfect fluid system in f(R) gravity, which is an important theory could explain the accelerated expansion of the universe. We first show that the Tolman-Oppenheimer-Volkoff equation of f(R) theories can be obtained by thermodynamical method in spherical symmetric spacetime. Then we prove that the maximum entropy principle is also valid for f(R) gravity in general static spacetimes beyond spherical symmetry. The result shows that if the constraint equation is satisfied and the temperature of fluid obeys Tolmans law, the extrema of total entropy implies other components of gravitational equations. Conversely, if f(R) gravitational equation hold, the total entropy of the fluid should be extremum. Our work suggests a general and solid connection between f(R) gravity and thermodynamics.

  11. Bladder carcinoma. Apport MR imaging

    International Nuclear Information System (INIS)

    Roy, C.; Spittler, G.; Jacqmin, D.; Morel, M.

    1991-01-01

    Bladder carcinoma is the second most commun cause of urogenital tumor. It is suspected by abdominal ultrasound and prouved by cystoscopy with biopsy. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging. Urography is still useful to appreciate urinary tract [fr

  12. Thermodynamic laws for generalized f(R) gravity with curvature-matter coupling

    International Nuclear Information System (INIS)

    Wu Yabo; Zhao Yueyue; Cai Ronggen; Lu Jianbo; Lu Junwang; Gao Xiaojing

    2012-01-01

    The first law and the generalized second law (GSL) of thermodynamics for the generalized f(R) gravity with curvature-matter coupling are studied in the spatially homogeneous, isotropic FRW universe. The research results show that the field equations of the generalized f(R) gravity with curvature-matter coupling can be cast to the form of the first law of thermodynamics with the so-called the entropy production terms dS ¯ and the GSL can be given by considering the FRW universe filled only with ordinary matter enclosed by the dynamical apparent horizon with the Hawking temperature. Furthermore, as a concrete example, by utilizing the GSL the constraints on the gravitational model with f 1 (R)=R+αR l and f 2 (R)=R m are also discussed. It is worth noting these results given by us are quite general and can degenerate to the ones in Einstein's general relativity and pure f(R) gravity with non-coupling and non-minimal coupling as special cases. Comparing with the case of Einstein's general relativity, the appearance of the entropy production term dS ¯ in the first law of thermodynamics demonstrates that the horizon thermodynamics is non-equilibrium one for generalized f(R) gravity with curvature-matter coupling, which is consistent with the arguments given in Akbar and Cai (2007) [13] and Eling et al. (2006) [18].

  13. Constraining f(R gravity in solar system, cosmology and binary pulsar systems

    Directory of Open Access Journals (Sweden)

    Tan Liu

    2018-02-01

    Full Text Available The f(R gravity can be cast into the form of a scalar–tensor theory, and scalar degree of freedom can be suppressed in high-density regions by the chameleon mechanism. In this article, for the general f(R gravity, using a scalar–tensor representation with the chameleon mechanism, we calculate the parametrized post-Newtonian parameters γ and β, the effective gravitational constant Geff, and the effective cosmological constant Λeff. In addition, for the general f(R gravity, we also calculate the rate of orbital period decay of the binary system due to gravitational radiation. Then we apply these results to specific f(R models (Hu–Sawicki model, Tsujikawa model and Starobinsky model and derive the constraints on the model parameters by combining the observations in solar system, cosmological scales and the binary systems.

  14. A no-hair theorem for black holes in f(R) gravity

    Science.gov (United States)

    Cañate, Pedro

    2018-01-01

    In this work we present a no-hair theorem which discards the existence of four-dimensional asymptotically flat, static and spherically symmetric or stationary axisymmetric, non-trivial black holes in the frame of f(R) gravity under metric formalism. Here we show that our no-hair theorem also can discard asymptotic de Sitter stationary and axisymmetric non-trivial black holes. The novelty is that this no-hair theorem is built without resorting to known mapping between f(R) gravity and scalar–tensor theory. Thus, an advantage will be that our no-hair theorem applies as well to metric f(R) models that cannot be mapped to scalar–tensor theory.

  15. 76 FR 65431 - National Pollutant Discharge Elimination System (NPDES) Concentrated Animal Feeding Operation...

    Science.gov (United States)

    2011-10-21

    ...). Ducks ( other than a liquid manure 30,000 or more....... 10,000-29,999........ Less than 10,000. handling system). Ducks (liquid manure handling 5,000 or more........ 1,500-4,999 Less than 1,500. system... Summary Feedlots Point Source Category Study, EPA-821-R-99-002 (1999), pp. 26-27. The health hazards that...

  16. Extension of loop quantum gravity to f(R) theories.

    Science.gov (United States)

    Zhang, Xiangdong; Ma, Yongge

    2011-04-29

    The four-dimensional metric f(R) theories of gravity are cast into connection-dynamical formalism with real su(2) connections as configuration variables. Through this formalism, the classical metric f(R) theories are quantized by extending the loop quantization scheme of general relativity. Our results imply that the nonperturbative quantization procedure of loop quantum gravity is valid not only for general relativity but also for a rather general class of four-dimensional metric theories of gravity.

  17. 26 CFR 1.414(r)-9 - Separate application of section 401(a)(26).

    Science.gov (United States)

    2010-04-01

    ....414(r)-9 Section 1.414(r)-9 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.414(r)-9... qualified separate lines of business for purposes of section 401(a)(26) in accordance with § 1.414(r)-1(b...

  18. 46 CFR 26.03-10 - Signaling light.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Signaling light. 26.03-10 Section 26.03-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS OPERATIONS Special Operating Requirements § 26.03-10 Signaling light. All vessels of over 150 gross tons, when engaged on an international...

  19. Constraint on reconstructed f(R) gravity models from gravitational waves

    Science.gov (United States)

    Lee, Seokcheon

    2018-06-01

    The gravitational wave (GW) detection of a binary neutron star inspiral made by the Advanced LIGO and Advanced Virgo paves the unprecedented way for multi-messenger observations. The propagation speed of this GW can be scrutinized by comparing the arrival times between GW and neutrinos or photons. It provides the constraint on the mass of the graviton. f(R) gravity theories have the habitual non-zero mass gravitons in addition to usual massless ones. Previously, we show that the model independent f(R) gravity theories can be constructed from the both background evolution and the matter growth with one undetermined parameter. We show that this parameter can be constrained from the graviton mass bound obtained from GW detection. Thus, the GW detection provides the invaluable constraint on the validity of f(R) gravity theories.

  20. Cosmic constraint on massive neutrinos in viable f(R) gravity with producing ΛCDM background expansion

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Jianbo; Wu, Yabo; Wang, Yan; Yang, Weiqiang [Liaoning Normal University, Department of Physics, Dalian (China); Liu, Molin [Xinyang Normal University, Department of Physics, Xinyang (China)

    2016-12-15

    Tensions between several cosmic observations were found recently, such as the inconsistent values of H{sub 0} (or σ{sub 8}) were indicated by the different cosmic observations. Introducing the massive neutrinos in ΛCDM could potentially solve the tensions. Viable f(R) gravity producing ΛCDM background expansion with massive neutrinos is investigated in this paper. We fit the current observational data: Planck-2015 CMB, RSD, BAO, and SNIa to constrain the mass of neutrinos in viable f(R) theory. The constraint results at 95% confidence level are: Σm{sub ν} < 0.202 eV for the active-neutrino case, m{sub ν,sterile}{sup eff} < 0.757 eV with N{sub eff} < 3.22 for the sterile neutrino case. For the effects due to the mass of the neutrinos, the constraint results on model parameter at 95% confidence level become f{sub R0} x 10{sup -6} > -1.89 and f{sub R0} x 10{sup -6} > -2.02 for two cases, respectively. It is also shown that the fitting values of several parameters much depend on the neutrino properties, such as the cold dark matter density, the cosmological quantities at matter-radiation equality, the neutrino density and the fraction of baryonic mass in helium. Finally, the constraint result shows that the tension between direct and CMB measurements of H{sub 0} gets slightly weaker in the viable f(R) model than that in the base ΛCDM model. (orig.)

  1. Analysis of pp and pp-bar in forward scattering using derivative dispersion relations

    International Nuclear Information System (INIS)

    Kohara, A. K.; Ferreira, E.; Kodama, T.

    2010-01-01

    We describe the amplitudes for pp and pp-bar scattering at small momentum transfers, where Coulomb and nuclear interference occurs, with special attention to the slopes of the real and imaginary parts. The forward amplitudes are assumed to have simple exponential forms, depending on four parameters σ, ρ, B I , B R , with B I ≠ B R .

  2. MR imaging of acute transverse myelitis (myelopathy)

    Energy Technology Data Exchange (ETDEWEB)

    Isoda, Haruo [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Ramsey, R.G.

    1998-05-01

    The purpose of our study was to review the MR characteristics of acute transverse myelitis (ATM) retrospectively and to review the literature. The subjects were 26 patients (two males, 24 females). MR examinations were carried out using a 1.5 Tesla scanner. MR imaging in eight of 16 lesions in nine subjects with preexisting MS showed multiple areas of increased signal intensity on T{sub 2}-weighted sagittal images, and 11 lesions had no cord swelling. Twelve of 16 lesions showed heterogeneous enhancement. MR imaging in 10 of 13 lesions in 12 subjects with preexisting HTLV-1 infection, mycoplasma pneumonia infection, hepatitis B vaccinations, and uncertain etiologies revealed fusiform increased signal intensity areas on T{sub 2}-weighted sagittal images and cord swelling. Seven of 11 lesions in the patients who underwent injection of contrast medium showed heterogeneous enhancement, whereas others showed no enhancement. MR examination is recommended for the evaluation of ATM. (author)

  3. Probing the f(R) formalism through gravitational wave polarizations

    International Nuclear Information System (INIS)

    Alves, M.E.S.; Miranda, O.D.; Araujo, J.C.N. de

    2009-01-01

    The direct observation of gravitational waves (GW) in the near future, and the corresponding determination of the number of independent polarizations, is a powerful tool to test general relativity and alternative theories of gravity. In the present work we use the Newman-Penrose formalism to characterize GWs in quadratic gravity and in a particular class of f(R) Lagrangians. We find that both quadratic gravity and the f(R) theory belong to the most general invariant class of GWs, i.e., they can present up to six independent polarizations of GWs. For a particular combination of the parameters, we find that quadratic gravity can present up to five polarizations states. On the other hand, if we use the Palatini approach for f(R) theories, GWs present only the usual two transverse-traceless polarizations such as in general relativity. Thus, we conclude that the observation of GWs can strongly constrain the suitable formalism for these theories.

  4. On Analytical Solutions of f(R) Modified Gravity Theories in FLRW Cosmologies

    Science.gov (United States)

    Domazet, Silvije; Radovanović, Voja; Simonović, Marko; Štefančić, Hrvoje

    2013-02-01

    A novel analytical method for f(R) modified theories without matter in Friedmann-Lemaitre-Robertson-Walker (FLRW) spacetimes is introduced. The equation of motion for the scale factor in terms of cosmic time is reduced to the equation for the evolution of the Ricci scalar R with the Hubble parameter H. The solution of equation of motion for actions of the form of power law in Ricci scalar R is presented with a detailed elaboration of the action quadratic in R. The reverse use of the introduced method is exemplified in finding functional forms f(R), which leads to specified scale factor functions. The analytical solutions are corroborated by numerical calculations with excellent agreement. Possible further applications to the phases of inflationary expansion and late-time acceleration as well as f(R) theories with radiation are outlined.

  5. f(R in Holographic and Agegraphic Dark Energy Models and the Generalized Uncertainty Principle

    Directory of Open Access Journals (Sweden)

    Barun Majumder

    2013-01-01

    Full Text Available We studied a unified approach with the holographic, new agegraphic, and f(R dark energy model to construct the form of f(R which in general is responsible for the curvature driven explanation of the very early inflation along with presently observed late time acceleration. We considered the generalized uncertainty principle in our approach which incorporated the corrections in the entropy-area relation and thereby modified the energy densities for the cosmological dark energy models considered. We found that holographic and new agegraphic f(R gravity models can behave like phantom or quintessence models in the spatially flat FRW universe. We also found a distinct term in the form of f(R which goes as R 3 / 2 due to the consideration of the GUP modified energy densities. Although the presence of this term in the action can be important in explaining the early inflationary scenario, Capozziello et al. recently showed that f(R ~ R 3 / 2 leads to an accelerated expansion, that is, a negative value for the deceleration parameter q which fits well with SNeIa and WMAP data.

  6. Contribution of dynamic contrast MR imaging to the differentiation between dural metastasis and meningioma

    International Nuclear Information System (INIS)

    Kremer, S.; Grand, S.; Le Bas, J.F.; Remy, C.; Pasquier, B.; Benabid, A.L.; Bracard, S.

    2004-01-01

    To determine the perfusion-sensitive characteristics of cerebral dural metastases and compare them with the data on meningiomas. Twenty-two patients presenting with dural tumor underwent conventional and dynamic susceptibility-contrast MR imaging: breast carcinoma metastases, two patients; colorectal carcinoma metastasis, one patient; lung carcinoma metastasis, one patient; Merkel carcinoma metastasis, one patient; lymphoma, one patient; meningiomas, 16 patients. The imaging characteristics were analyzed using conventional MR imaging. The cerebral blood volume (CBV) maps were obtained for each patient and the relative CBV (rCBV) in different areas was calculated using the ratio between the CBV in the pathological area (CBVp) and in the contralateral white matter (CBVn). The differentiation between a meningioma and a dural metastasis can be difficult using conventional MR imaging. The rCBVs of lung carcinoma metastasis (1 case: 1.26), lymphoma (1 case: 1.29), breast carcinoma metastasis (2 cases: 1.50,1.56) and rectal carcinoma metastasis (1 case: 3.34) were significantly lower than that of meningiomas (16 cases: mean rCBV = 8.97±4.34, range 4-18). Merkel carcinoma metastasis (1 case: 7.56) showed an elevated rCBV, not different from that of meningiomas. Dural metastases are sometimes indistinguishable from meningiomas using conventional MR imaging. rCBV mapping can provide additional information by demonstrating a low rCBV which may suggest the diagnosis of metastasis. (orig.)

  7. Reconstructing an f(R) model from holographic dark energy: using the observational evidence

    International Nuclear Information System (INIS)

    Saaidi, Kh; Aghamohammadi, A

    2012-01-01

    We investigate the correspondence relation between f(R) gravity and an interacting holographic dark energy (HDE). By obtaining the conditions needed for some observational evidence such as positive acceleration expansion of the Universe, crossing the phantom divide line and validity of the thermodynamics second law in an interacting HDE model and corresponding it with the f(R) model of gravity, we find a viable f(R) model that can explain the present Universe. We also obtain the explicit evolutionary forms of the corresponding scalar field, potential and scale factor of the Universe. (paper)

  8. String duality transformations in f(R) gravity from Noether symmetry approach

    Energy Technology Data Exchange (ETDEWEB)

    Capozziello, Salvatore [Dipartimento di Fisica, Università di Napoli ' ' Federico II' ' , Compl. Univ. di Monte S. Angelo, Edificio G, Via Cinthia, I-80126, Napoli (Italy); Gionti, Gabriele S.J. [Specola Vaticana, Vatican City, V-00120, Vatican City State (Vatican City State, Holy See); Vernieri, Daniele, E-mail: capozziello@na.inf.it, E-mail: ggionti@as.arizona.edu, E-mail: vernieri@iap.fr [Sorbonne Universités, UPMC Univ Paris 6 et CNRS, UMR 7095, Institut d' Astrophysique de Paris, GReCO, 98bis Bd Arago, 75014 Paris (France)

    2016-01-01

    We select f(R) gravity models that undergo scale factor duality transformations. As a starting point, we consider the tree-level effective gravitational action of bosonic String Theory coupled with the dilaton field. This theory inherits the Busher's duality of its parent String Theory. Using conformal transformations of the metric tensor, it is possible to map the tree-level dilaton-graviton string effective action into f(R) gravity, relating the dilaton field to the Ricci scalar curvature. Furthermore, the duality can be framed under the standard of Noether symmetries and exact cosmological solutions are derived. Using suitable changes of variables, the string-based f(R) Lagrangians are shown in cases where the duality transformation becomes a parity inversion.

  9. String duality transformations in f(R) gravity from Noether symmetry approach

    International Nuclear Information System (INIS)

    Capozziello, Salvatore; Gionti, Gabriele S.J.; Vernieri, Daniele

    2016-01-01

    We select f(R) gravity models that undergo scale factor duality transformations. As a starting point, we consider the tree-level effective gravitational action of bosonic String Theory coupled with the dilaton field. This theory inherits the Busher's duality of its parent String Theory. Using conformal transformations of the metric tensor, it is possible to map the tree-level dilaton-graviton string effective action into f(R) gravity, relating the dilaton field to the Ricci scalar curvature. Furthermore, the duality can be framed under the standard of Noether symmetries and exact cosmological solutions are derived. Using suitable changes of variables, the string-based f(R) Lagrangians are shown in cases where the duality transformation becomes a parity inversion

  10. Unifying inflation with dark energy in modified F(R) Horava-Lifshitz gravity

    International Nuclear Information System (INIS)

    Elizalde, E.; Saez-Gomez, D.; Nojiri, S.; Odintsov, S.D.

    2010-01-01

    We study FRW cosmology for a non-linear modified F(R) Horava-Lifshitz gravity which has a viable convenient counterpart. A unified description of early-time inflation and late-time acceleration is possible in this theory, but the cosmological dynamic details are generically different from the ones of the convenient viable F(R) model. Remarkably, for some specific choice of parameters they do coincide. The emergence of finite-time future singularities is investigated in detail. It is shown that these singularities can be cured by adding an extra, higher-derivative term, which turns out to be qualitatively different when compared with the corresponding one of the convenient F(R) theory. (orig.)

  11. Evidence for CP violation in B+ → ppK+ decays.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Affolder, A; Ajaltouni, Z; Akar, S; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; An, L; Anderlini, L; Anderson, J; Andreassen, R; Andreotti, M; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Badalov, A; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Batozskaya, V; Battista, V; Bay, A; Beaucourt, L; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Borsato, M; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brodzicka, J; Brook, N H; Brown, H; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Calabrese, R; Calvi, M; Calvo Gomez, M; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cassina, L; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Chefdeville, M; Chen, S; Cheung, S-F; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Corvo, M; Counts, I; Couturier, B; Cowan, G A; Craik, D C; Cruz Torres, M; Cunliffe, S; Currie, R; D'Ambrosio, C; Dalseno, J; David, P; David, P N Y; Davis, A; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Donleavy, S; Dordei, F; Dorigo, M; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dreimanis, K; Dujany, G; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Ely, S; Esen, S; Evans, H-M; Evans, T; Falabella, A; Färber, C; Farinelli, C; Farley, N; Farry, S; Fay, Rf; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fiorini, M; Firlej, M; Fitzpatrick, C; Fiutowski, T; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Fu, J; Furfaro, E; Gallas Torreira, A; Galli, D; Gallorini, S; Gambetta, S; Gandelman, M; Gandini, P; Gao, Y; García Pardiñas, J; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gavardi, L; Gavrilov, G; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gianelle, A; Giani', S; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gotti, C; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grillo, L; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Han, X; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Henry, L; Hernando Morata, J A; van Herwijnen, E; Heß, M; Hicheur, A; Hill, D; Hoballah, M; Hombach, C; Hulsbergen, W; Hunt, P; Hussain, N; Hutchcroft, D; Hynds, D; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jalocha, J; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Jurik, N; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Karodia, S; Kelsey, M; Kenyon, I R; Ketel, T; Khanji, B; Khurewathanakul, C; Klaver, S; Klimaszewski, K; Kochebina, O; Kolpin, M; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucewicz, W; Kucharczyk, M; Kudryavtsev, V; Kurek, K; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanfranchi, G; Langenbruch, C; Langhans, B; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Likhomanenko, T; Liles, M; Lindner, R; Linn, C; Lionetto, F; Liu, B; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lowdon, P; Lu, H; Lucchesi, D; Luo, H; Lupato, A; Luppi, E; Lupton, O; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Malinin, A; Manca, G; Mancinelli, G; Maratas, J; Marchand, J F; Marconi, U; Marin Benito, C; Marino, P; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martinez Vidal, F; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Mazurov, A; McCann, M; McCarthy, J; McNab, A; McNulty, R; McSkelly, B; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M-N; Moggi, N; Molina Rodriguez, J; Monteil, S; Morandin, M; Morawski, P; Mordà, A; Morello, M J; Moron, J; Morris, A-B; Mountain, R; Muheim, F; Müller, K; Mussini, M; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neri, N; Neubert, S; Neufeld, N; Neuner, M; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Novoselov, A; O'Hanlon, D P; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Onderwater, G; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palombo, F; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Pappalardo, L L; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrignani, C; Pazos Alvarez, A; Pearce, A; Pellegrino, A; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Perret, P; Perrin-Terrin, M; Pescatore, L; Pesen, E; Petridis, K; Petrolini, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Pistone, A; Playfer, S; Plo Casasus, M; Polci, F; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Price, E; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rachwal, B; Rademacker, J H; Rakotomiaramanana, B; Rama, M; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Reichert, S; Reid, M M; Dos Reis, A C; Ricciardi, S; Richards, S; Rihl, M; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, A B; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rotondo, M; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanchez Mayordomo, C; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sarti, A; Satriano, C; Satta, A; Saunders, D M; Savrie, M; Savrina, D; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Sepp, I; Serra, N; Serrano, J; Sestini, L; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, V; Shires, A; Silva Coutinho, R; Simi, G; Sirendi, M; Skidmore, N; Skwarnicki, T; Smith, N A; Smith, E; Smith, E; Smith, J; Smith, M; Snoek, H; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Sridharan, S; Stagni, F; Stahl, M; Stahl, S; Steinkamp, O; Stenyakin, O; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Stracka, S; Straticiuc, M; Straumann, U; Stroili, R; Subbiah, V K; Sun, L; Sutcliffe, W; Swientek, K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szilard, D; Szumlak, T; T'Jampens, S; Teklishyn, M; Tellarini, G; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tomassetti, L; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vieites Diaz, M; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; de Vries, J A; Waldi, R; Wallace, C; Wallace, R; Walsh, J; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Websdale, D; Whitehead, M; Wicht, J; Wiedner, D; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Xu, Z; Yang, Z; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2014-10-03

    Three-body B+ → ppK+ and B(+) → ppπ(+) decays are studied using a data sample corresponding to an integrated luminosity of 3.0 fb(-1) collected by the LHCb experiment in proton-proton collisions at center-of-mass energies of 7 and 8 TeV. Evidence of CP violation in the B(+) → ppK(+) decay is found in regions of the phase space, representing the first measurement of this kind for a final state containing baryons. Measurements of the forward-backward asymmetry of the light meson in the pp rest frame yield A(FB)(ppK(+),m(pp)m(pp) <2.85 GeV/c(2)) = -0.409 ± 0.033 (stat) ± 0.006 (syst). In addition, the branching fraction of the decay B(+) → Λ(1520)p is measured to be B(B(+) → Λ(1520)p) = (3.15 ± 0.48 (stat) ± 0.07 (syst) ± 0.26 (BF)) × 10(-7), where BF denotes the uncertainty on secondary branching fractions.

  12. The crucial role of PpMYB10.1 in anthocyanin accumulation in peach and relationships between its allelic type and skin color phenotype.

    Science.gov (United States)

    Tuan, Pham Anh; Bai, Songling; Yaegaki, Hideaki; Tamura, Takayuki; Hihara, Seisuke; Moriguchi, Takaya; Oda, Kenji

    2015-11-18

    Red coloration of fruit skin is one of the most important traits in peach (Prunus persica), and it is mainly due to the accumulation of anthocyanins. Three MYB10 genes, PpMYB10.1, PpMYB10.2, and PpMYB10.3, have been reported as important regulators of red coloration and anthocyanin biosynthesis in peach fruit. In this study, contribution of PpMYB10.1/2/3 to anthocyanin accumulation in the fruit skin was investigated in the Japanese peach cultivars, white-skinned 'Mochizuki' and red-skinned 'Akatsuki'. We then investigated the relationships between allelic type of PpMYB10.1 and skin color phenotype in 23 Japanese peach cultivars for future establishment of DNA-marker. During the fruit development of 'Mochizuki' and 'Akatsuki', anthocyanin accumulation was observed only in the skin of red 'Akatsuki' fruit in the late ripening stages concomitant with high mRNA levels of the last step gene leading to anthocyanin accumulation, UDP-glucose:flavonoid-3-O-glucosyltransferase (UFGT). This was also correlated with the expression level of PpMYB10.1. Unlike PpMYB10.1, expression levels of PpMYB10.2/3 were low in the skin of both 'Mochizuki' and 'Akatsuki' throughout fruit development. Moreover, only PpMYB10.1 revealed expression levels associated with total anthocyanin accumulation in the leaves and flowers of 'Mochizuki' and 'Akatsuki'. Introduction of PpMYB10.1 into tobacco increased the expression of tobacco UFGT, resulting in higher anthocyanin accumulation and deeper red transgenic tobacco flowers; however, overexpression of PpMYB10.2/3 did not alter anthocyanin content and color of transgenic tobacco flowers when compared with wild-type flowers. Dual-luciferase assay showed that the co-infiltration of PpMYB10.1 with PpbHLH3 significantly increased the activity of PpUFGT promoter. We also found close relationships of two PpMYB10.1 allelic types, MYB10.1-1/MYB10.1-2, with the intensity of red skin coloration. We showed that PpMYB10.1 is a major regulator of anthocyanin

  13. MR imaging features of foot involvement in patients with psoriasis

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey)], E-mail: sunarerdem@yahoo.com; Tekin, Nilgun Solak [Department of Dermatology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Sarikaya, Selda [Department of Physical Therapy and Rehabilitation, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Erdem, L. Oktay; Gulec, Sezen [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey)

    2008-09-15

    Objective: To determine alterations of the soft tissues, tendons, cartilage, joint spaces, and bones of the foot using magnetic resonance (MR) imaging in patients with psoriasis. Materials and methods: Clinical and MR examination of the foot was performed in 26 consecutive patients (52 ft) with psoriasis. As a control group, 10 healthy volunteers (20 ft) were also studied. Joint effusion/synovitis, retrocalcaneal bursitis, retroachilles bursitis, Achilles tendonitis, soft-tissue edema, para-articular enthesophytes, bone marrow edema, sinus tarsi syndrome, enthesopathy at the Achilles attachment and at the plantar fascia attachment, plantar fasciitis, tenosynovitis, subchondral cysts, and bone erosions, joint space narrowing, subchondral signal changes, osteolysis, luxation, and sub-luxation were examined. Results: Clinical signs and symptoms (pain and swelling) due to foot involvement were present in none of the patients while frequency of involvement was 92% (24/26) by MR imaging. The most common MR imaging findings were Achilles tendonitis (acute and peritendinitis) (57%), retrocalcaneal bursitis (50%), joint effusion/synovitis (46%), soft-tissue edema (46%), and para-articular enthesophytes (38%). The most commonly involved anatomical region was the hindfoot (73%). Conclusion: Our data showed that the incidence of foot involvement was very high in asymptomatic patients with psoriasis on MR imaging. Further MR studies are needed to confirm these data. We conclude that MR imaging may be of importance especially in early diagnosis and treatment of inflammatory changes in the foot.

  14. MR imaging features of foot involvement in patients with psoriasis

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Tekin, Nilgun Solak; Sarikaya, Selda; Erdem, L. Oktay; Gulec, Sezen

    2008-01-01

    Objective: To determine alterations of the soft tissues, tendons, cartilage, joint spaces, and bones of the foot using magnetic resonance (MR) imaging in patients with psoriasis. Materials and methods: Clinical and MR examination of the foot was performed in 26 consecutive patients (52 ft) with psoriasis. As a control group, 10 healthy volunteers (20 ft) were also studied. Joint effusion/synovitis, retrocalcaneal bursitis, retroachilles bursitis, Achilles tendonitis, soft-tissue edema, para-articular enthesophytes, bone marrow edema, sinus tarsi syndrome, enthesopathy at the Achilles attachment and at the plantar fascia attachment, plantar fasciitis, tenosynovitis, subchondral cysts, and bone erosions, joint space narrowing, subchondral signal changes, osteolysis, luxation, and sub-luxation were examined. Results: Clinical signs and symptoms (pain and swelling) due to foot involvement were present in none of the patients while frequency of involvement was 92% (24/26) by MR imaging. The most common MR imaging findings were Achilles tendonitis (acute and peritendinitis) (57%), retrocalcaneal bursitis (50%), joint effusion/synovitis (46%), soft-tissue edema (46%), and para-articular enthesophytes (38%). The most commonly involved anatomical region was the hindfoot (73%). Conclusion: Our data showed that the incidence of foot involvement was very high in asymptomatic patients with psoriasis on MR imaging. Further MR studies are needed to confirm these data. We conclude that MR imaging may be of importance especially in early diagnosis and treatment of inflammatory changes in the foot

  15. Investigating the early stages of Photosystem II assembly in Synechocystis sp. PCC 6803: isolation of CP47 and CP43 complexe

    Czech Academy of Sciences Publication Activity Database

    Boehm, M.; Romero, E.; Reisinger, V.; Yu, J.; Komenda, Josef; Eichacker, L. A.; Dekker, J. P.; Nixon, P. J.

    2011-01-01

    Roč. 286, č. 17 (2011), 14812-14819 ISSN 0021-9258 R&D Projects: GA AV ČR IAA400200801 Institutional research plan: CEZ:AV0Z50200510 Keywords : ENERGY CHLOROPHYLL STATES * ANTENNA PROTEIN COMPLEX * OXYGEN-EVOLVING CENTER Subject RIV: EE - Microbiology, Virology Impact factor: 4.773, year: 2011

  16. Late time acceleration of the universe in f(R) gravity model

    International Nuclear Information System (INIS)

    Mukherjee, Ankan

    2014-01-01

    In this work, a new way to look at the nature of late time dynamics of the universe for f(R) gravity models using the contracted Bianchi Identity has been proposed. As the Einstein field equations contain derivatives of the curvature scalar R, the contracted Bianchi identity yields a second order nonlinear differential equation in H, the Hubble parameter. This equation is studied for two particular forms of f(R), and the late time behaviour of the model is discussed. (author)

  17. Stability of the Einstein static universe in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shabani, Hamid [University of Sistan and Baluchestan, Physics Department, Faculty of Sciences, Zahedan (Iran, Islamic Republic of); Ziaie, Amir Hadi [Kahnooj Branch, Islamic Azad University, Department of Physics, Kerman (Iran, Islamic Republic of)

    2017-01-15

    The Einstein static (ES) universe has played a major role in various emergent scenarios recently proposed in order to cure the problem of the initial singularity of the standard model of cosmology. In the model we address, we study the existence and stability of an ES universe in the context of f(R, T) modified theories of gravity. Considering specific forms of the f(R, T) function, we seek for the existence of solutions representing ES state. Using dynamical system techniques along with numerical analysis, we find two classes of solutions: the first one is always unstable of the saddle type, while the second is always stable so that its dynamical behavior corresponds to a center equilibrium point. The importance of the second class of solutions is due to the significant role they play in constructing non-singular emergent models in which the universe could have experienced past-eternally a series of infinite oscillations about such an initial static state after which it enters, through a suitable physical mechanism, to an inflationary era. Considering specific forms for the functionality of f(R, T), we show that this theory is capable of providing cosmological solutions which admit emergent universe (EU) scenarios. We also investigate homogeneous scalar perturbations for the mentioned models. The stability regions of the solutions are parametrized by a linear equation of state (EoS) parameter and other free parameters that will be introduced for the models. Our results suggest that modifications in f(R, T) gravity would lead to stable solutions which are unstable in f(R) gravity model. (orig.)

  18. Stability of the Einstein static universe in f(R, T) gravity

    International Nuclear Information System (INIS)

    Shabani, Hamid; Ziaie, Amir Hadi

    2017-01-01

    The Einstein static (ES) universe has played a major role in various emergent scenarios recently proposed in order to cure the problem of the initial singularity of the standard model of cosmology. In the model we address, we study the existence and stability of an ES universe in the context of f(R, T) modified theories of gravity. Considering specific forms of the f(R, T) function, we seek for the existence of solutions representing ES state. Using dynamical system techniques along with numerical analysis, we find two classes of solutions: the first one is always unstable of the saddle type, while the second is always stable so that its dynamical behavior corresponds to a center equilibrium point. The importance of the second class of solutions is due to the significant role they play in constructing non-singular emergent models in which the universe could have experienced past-eternally a series of infinite oscillations about such an initial static state after which it enters, through a suitable physical mechanism, to an inflationary era. Considering specific forms for the functionality of f(R, T), we show that this theory is capable of providing cosmological solutions which admit emergent universe (EU) scenarios. We also investigate homogeneous scalar perturbations for the mentioned models. The stability regions of the solutions are parametrized by a linear equation of state (EoS) parameter and other free parameters that will be introduced for the models. Our results suggest that modifications in f(R, T) gravity would lead to stable solutions which are unstable in f(R) gravity model. (orig.)

  19. Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR.

    Science.gov (United States)

    Maus, Jens; Schramm, Georg; Hofheinz, Frank; Oehme, Liane; Lougovski, Alexandr; Petr, Jan; Platzek, Ivan; Beuthien-Baumann, Bettina; Steinbach, Jörg; Kotzerke, Jörg; van den Hoff, Jörg

    2015-10-01

    time, the linearity scans revealed a systematic error of 8%-11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 -0.941), P = 1.1 ⋅ 10(-10). After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693-0.992), P = 3.9 ⋅ 10(-8). Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

  20. Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Maus, Jens, E-mail: j.maus@hzdr.de; Schramm, Georg; Hofheinz, Frank; Lougovski, Alexandr; Petr, Jan; Steinbach, Jörg [PET Center, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, P.O. Box 510119, 01314 Dresden (Germany); Oehme, Liane; Beuthien-Baumann, Bettina; Kotzerke, Jörg [Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, 01307 Dresden (Germany); Platzek, Ivan [Department of Radiology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, 01307 Dresden (Germany); Hoff, Jörg van den [PET Center, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, P.O. Box 510119, 01314 Dresden, Germany and Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, 01307 Dresden (Germany)

    2015-10-15

    true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

  1. Structure and Mechanism of Receptoe Sharing by the IL-10R2 Common Chain

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sung-il; Jones, Brandi C.; Logsdon, Naomi J.; Harris, Bethany D.; Deshpande, Ashlesha; Radaeva, Svetlana; Halloran, Brian A.; Gao, Bin; Walter, Mark R. (NIH); (UAB)

    2010-06-14

    IL-10R2 is a shared cell surface receptor required for the activation of five class 2 cytokines (IL-10, IL-22, IL-26, IL-28, and IL-29) that play critical roles in host defense. To define the molecular mechanisms that regulate its promiscuous binding, we have determined the crystal structure of the IL-10R2 ectodomain at 2.14 {angstrom} resolution. IL-10R2 residues required for binding were identified by alanine scanning and used to derive computational models of IL-10/IL-10R1/IL-10R2 and IL-22/IL-22R1/IL-10R2 ternary complexes. The models reveal a conserved binding epitope that is surrounded by two clefts that accommodate the structural and chemical diversity of the cytokines. These results provide a structural framework for interpreting IL-10R2 single nucleotide polymorphisms associated with human disease.

  2. Structure and Mechanism of Receptor Sharing by the IL-10R2 Common Chain

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sung-il; Jones, Brandi C.; Logsdon, Naomi J.; Harris, Bethany D.; Deshpande, Ashlesha; Radaeva, Svetlana; Halloran, Brian A.; Gao, Bin; Walter, Mark R. (NIH); (UAB)

    2010-07-19

    IL-10R2 is a shared cell surface receptor required for the activation of five class 2 cytokines (IL-10, IL-22, IL-26, IL-28, and IL-29) that play critical roles in host defense. To define the molecular mechanisms that regulate its promiscuous binding, we have determined the crystal structure of the IL-10R2 ectodomain at 2.14 {angstrom} resolution. IL-10R2 residues required for binding were identified by alanine scanning and used to derive computational models of IL-10/IL-10R1/IL-10R2 and IL-22/IL-22R1/IL-10R2 ternary complexes. The models reveal a conserved binding epitope that is surrounded by two clefts that accommodate the structural and chemical diversity of the cytokines. These results provide a structural framework for interpreting IL-10R2 single nucleotide polymorphisms associated with human disease.

  3. (1S,3S,8R,9S,10R-9,10-Epoxy-3,7,7,10-tetramethyltricyclo[6.4.0.01,3]dodecane

    Directory of Open Access Journals (Sweden)

    Abdoullah Bimoussa

    2014-04-01

    Full Text Available The title compound, C16H26O, was synthesized by treating (1S,3S,8R-3,7,7,10-tetramethyltricyclo[6.4.0.01,3]dodec-9-ene with metachloroperbenzoic acid. The molecule is built up from two fused six- and seven-membered rings. The six-membered ring has a half-chair conformation, whereas the seven-membered ring displays a boat conformation. In the crystal, there are no significant intermolecular interactions present.

  4. Exact solutions for scalar field cosmology in f(R) gravity

    Science.gov (United States)

    Maharaj, S. D.; Goswami, R.; Chervon, S. V.; Nikolaev, A. V.

    2017-09-01

    We study scalar field FLRW cosmology in the content of f(R) gravity. Our consideration is restricted to the spatially flat Friedmann universe. We derived the general evolution equations of the model, and showed that the scalar field equation is automatically satisfied for any form of the f(R) function. We also derived representations for kinetic and potential energies, as well as for the acceleration in terms of the Hubble parameter and the form of the f(R) function. Next we found the exact cosmological solutions in modified gravity without specifying the f(R) function. With negligible acceleration of the scalar curvature, we found that the de Sitter inflationary solution is always attained. Also we obtained new solutions with special restrictions on the integration constants. These solutions contain oscillating, accelerating, decelerating and even contracting universes. For further investigation, we selected special cases which can be applied with early or late inflation. We also found exact solutions for the general case for the model with negligible acceleration of the scalar curvature in terms of special Airy functions. Using initial conditions which represent the universe at the present epoch, we determined the constants of integration. This allows for the comparison of the scale factor in the new solutions with that for current stage of the universe evolution in the ΛCDM model.

  5. Chameleon halo modeling in f(R) gravity

    International Nuclear Information System (INIS)

    Li Yin; Hu, Wayne

    2011-01-01

    We model the chameleon effect on cosmological statistics for the modified gravity f(R) model of cosmic acceleration. The chameleon effect, required to make the model compatible with local tests of gravity, reduces force enhancement as a function of the depth of the gravitational potential wells of collapsed structure and so is readily incorporated into a halo model by including parameters for the chameleon mass threshold and rapidity of transition. We show that the abundance of halos around the chameleon mass threshold is enhanced by both the merging from below and the lack of merging to larger masses. This property also controls the power spectrum in the nonlinear regime and we provide a description of the transition to the linear regime that is valid for a wide range of f(R) models.

  6. PP-O and PP-V, Monascus pigment homologues, production, and phylogenetic analysis in Penicillium purpurogenum.

    Science.gov (United States)

    Arai, Teppei; Kojima, Ryo; Motegi, Yoshiki; Kato, Jun; Kasumi, Takafumi; Ogihara, Jun

    2015-12-01

    The production of pigments as secondary metabolites by microbes is known to vary by species and by physiological conditions within a single strain. The fungus strain Penicillium purpurogenum IAM15392 has been found to produce violet pigment (PP-V) and orange pigment (PP-O),Monascus azaphilone pigment homologues, when grown under specific culture conditions. In this study, we analysed PP-V and PP-O production capability in seven strains of P. purpurogenum in addition to strain IAM15392 under specific culture conditions. The pigment production pattern of five strains cultivated in PP-V production medium was similar to that of strain IAM15392, and all violet pigments produced by these five strains were confirmed to be PP-V. Strains that did not produce pigment were also identified. In addition, two strains cultivated in PP-O production medium produced a violet pigment identified as PP-V. The ribosomal DNA (rDNA) internal transcribed spacer (ITS) region sequences from the eight P. purpurogenum strains were sequenced and used to construct a neighbor-joining phylogenetic tree. PP-O and PP-V production of P. purpurogenum was shown to be related to phylogenetic placement based on rDNA ITS sequence. Based on these results, two hypotheses for the alteration of pigment production of P. purpurogenum in evolution were proposed. Copyright © 2015 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  7. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  8. Thick brane in f(R) gravity with Palatini dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bazeia, D.; Losano, L. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Menezes, R. [Universidade Federal da Paraiba, Departamento de Ciencias Exatas, Rio Tinto, PB (Brazil); Universidade Federal de Campina Grande, Departamento de Fisica, Campina Grande, PB (Brazil); Olmo, Gonzalo J. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Universidad de Valencia, Departamento de Fisica Teorica, IFIC, Centro Mixto Universidad de Valencia-CSIC, Burjassot, Valencia (Spain); Rubiera-Garcia, D. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Universidade de Lisboa, Faculdade de Ciencias, Instituto de Astrofisica e Ciencias do Espaco, Lisbon (Portugal); Fudan University, Department of Physics, Center for Field Theory and Particle Physics, Shanghai (China)

    2015-12-15

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R) = R + εR{sup n}, where the small parameter ε controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections. (orig.)

  9. M.R. imaging of spinal disorders

    International Nuclear Information System (INIS)

    Akino, Minoru; Isu, Toyohiko; Iwasaki, Yoshinobu; Abe, Hiroshi; Abe, Satoru; Miyasaka, Kazuo; Nomura, Mikio; Saito, Hisatoshi.

    1987-01-01

    In many papers about the M.R. imaging of spinal disorders, almost all the diagnoses have been carried out using only the sagittal image. However, we ourselves have thus for diagnosed about 500 cases of spinal disorders using the resistive type of MRI (0.15 T). On the basis of our experience, we have established two main principles as regards the MRI diagnosis of spinal disorders: 1) a surface coil must be used in the diagnosis of spinal disorders, and 2) diagnosis must be carried out by the use of both sagittal and axial images. We present some typical cases of spinal disorders in this paper. From these cases, we see that MRI has advantages and disadvantages as regards the diagnosis of spinal disorders compared with X-ray diagnostic apparatus. The first advantageous point is that we can directly obtain an image of the spinal cord without the intrathecal injection of a contrast material. The second point is that MRI can avoid the bone artifacts which often occur when using the X-ray CT; moreover, there is none of the hazard connected with the use of X-rays. The biggest disadvantage is that the spatial resolution of the resistive type of MRI is slightly inferior to that of the high-resolutional X-ray CT. The second disadvantage is that the ability to detect an ossificative process, such as disc disease or OPLL, is very restricted because of the low signal intensity from the cortical bone. We propose two points for the improvement of the MR imaging of spinal disorders. One is the production of a high-sensitivity surface coil. The other is the application of Gd-DTPA, which is thought to have a high potential to detect spinal disorders. If we can realize these points, the images of spinal disorders produced by the resistive type of MRI will be clearer and more informative. (J.P.N.)

  10. Physical attributes of anisotropic compact stars in f(R, G) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M.F.; Zia, Saeeda [National University of Computer and Emerging Sciences, Department of Sciences and Humanities, Lahore (Pakistan)

    2017-07-15

    Modified gravity is one of the potential candidates to explain the accelerated expansion of the universe. Current study highlights the materialization of anisotropic compact stars in the context of f(R, G) theory of gravity. In particular, to gain insight in the physical behavior of three stars namely, Her X1, SAX J 1808-3658 and 4U 1820-30, energy density, and radial and tangential pressures are calculated. The f(R, G) gravity model is split into a Starobinsky like f(R) model and a power law f(G) model. The main feature of the work is a 3-dimensional graphical analysis in which, anisotropic measurements, energy conditions and stability attributes of these stars are discussed. It is shown that all three stars behave as usual for positive values of the f(G) model parameter n. (orig.)

  11. Diffusion-weighted MR imaging of kidneys in renal artery stenosis

    International Nuclear Information System (INIS)

    Yildirim, Erkan; Kirbas, Ismail; Teksam, Mehmet; Karadeli, Elif; Gullu, Hakan; Ozer, Ismail

    2008-01-01

    Objective: The purpose of our study was to evaluate perfusion and diffusion of kidneys in renal artery stenosis (RAS) and any correlation between stenosis and ADC values and whether this imaging modality may be a noninvasive complementary assessment technique to MR angiography before interventional procedures. Materials and methods: Twenty consecutive patients suspected of having renal artery stenosis were evaluated with renal MR angiography to exclude stenosis and were then included in the study. Transverse DW multisection echo-planar MR imaging was performed. In the transverse ADC map, rectangular regions of interest were placed in the cortex on 3 parts (upper, middle, and lower poles) in each kidney. ADCs of the kidneys were calculated separately for the low, average, and high b-values to enable differentiation of the relative influence of the perfusion fraction and true diffusion. The ADC values of 39 kidneys (13 with renal artery stenosis and 26 normal renal arteries) were compared, and the relationship between stenosis degree and ADC values was calculated. Results: RAS was detected in 11 of 20 (55%) patients with MRA. Thirteen of 39 kidneys demonstrated RAS, and 26 were normal. The ADC low (1.9 ± 0.2 versus 2.1 ± 0.2; P = .020), ADC average (1.7 ± 0.2 versus 1.9 ± 0.1; P = .006), and ADC high (1.8 ± 0.2 versus 2.0 ± 0.1; P = .012) values were significantly lower in patients with kidneys with arterial stenosis than that in patients with kidneys with normal arteries. Statistical analysis revealed that stenosis degree correlated strongly with ADC low (r = -.819; P = .001), ADC average (r = -.754; P = .003), and ADC high (r = -.788; P = .001). The ADC low , ADC average , and ADC high values were significantly lower in patients with kidneys with arterial stenosis than that in patients with kidneys with normal arteries. Conclusion: We think that DW MR imaging of kidneys with RAS can help determine the functional status of a renal artery stenosis

  12. Correlation between intravoxel incoherent motion MR parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome: A pilot study

    International Nuclear Information System (INIS)

    Chu, Chen; Zhou, Nan; Zhang, Huayong; Dou, Xin; Li, Ming; Liu, Song; Zhu, Yun; Chen, Weibo; Chan, Queenie; He, Jian; Sun, Lingyun; Zhou, Zhengyang

    2017-01-01

    Highlights: • Parotid glands at grade 0–3 had significant values from those in healthy glands. • Parotid D and f values were correlated with MR nodule grade significantly. • There were significant differences of D, f, and D * values among glands at grade 0–3. - Abstract: Purpose: To explore the correlation between intravoxel incoherent motion (IVIM) magnetic resonance (MR) parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome (SS). Materials and methods: A total of 31 consecutive patients with SS and 28 gender- and age-matched healthy volunteers underwent bilateral parotid 3.0T MR examination including the IVIM sequence (9 b values, 0–800 s/mm 2 ). The apparent diffusion coefficient (ADC), diffusion coefficient D, pseudo-diffusion coefficient D * , and perfusion fraction f of bilateral parotid glands were obtained, and the nodular grade of each parotid gland was evaluated according to the MR morphological appearance. Results: Sixty-two parotid glands in 31 patients with SS consisted of 32, 14, 8, and 8 parotid glands at MR nodular grades 0, 1, 2, and 3, respectively. In parotid glands of grade 0, 1, 2, 3 and healthy volunteers, the ADC values were (1.13 ± 0.25, 1.11 ± 0.17, 1.05 ± 0.24, 0.89 ± 0.04 and 1.00 ± 0.21) × 10 −3 mm 2 /s, D values were (0.92 ± 0.13, 0.90 ± 0.19, 0.90 ± 0.03, 0.67 ± 0.03, 0.81 ± 0.03) × 10 −3 mm 2 /s, f values were 0.20 ± 0.04, 0.18 ± 0.02, 0.15 ± 0.01, 0.11 ± 0.01, 0.15 ± 0.06, and D * values were (53.89 ± 28.26, 41.78 ± 16.35, 51.24 ± 18.69, 31.83 ± 18.03, 36.83 ± 16.14) × 10 −3 mm 2 /s respectively. The ADC, D, f, and D * values of parotid glands in patients with SS at grade 0 were significantly higher than those in healthy volunteers (all P < 0.05). Significant differences were observed in the D and f values of parotid glands in patients with SS among different grades (P = 0.003, < 0.001, respectively). The IVIM parameters (D, f) of parotid glands at early

  13. Correlation between intravoxel incoherent motion MR parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Chen, E-mail: chuchen19920905@163.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Zhou, Nan, E-mail: snscorpion@163.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Zhang, Huayong, E-mail: 13770560567@163.com [Department of Rheumatology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Dou, Xin, E-mail: douxin125@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Li, Ming, E-mail: lm069393@163.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Liu, Song, E-mail: liusongnj@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Zhu, Yun, E-mail: qqt111@hotmail.com [Department of Rheumatology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Chen, Weibo, E-mail: Weibo.Chen@philips.com [Philips Healthcare, Shanghai, 200233 (China); Chan, Queenie, E-mail: queenie.chan@philips.com [Philips Healthcare, Hong Kong (China); He, Jian, E-mail: hjxueren@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Sun, Lingyun, E-mail: lysun_nju@163.com [Department of Rheumatology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China); Zhou, Zhengyang, E-mail: zyzhou@nju.edu.cn [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008 (China)

    2017-01-15

    Highlights: • Parotid glands at grade 0–3 had significant values from those in healthy glands. • Parotid D and f values were correlated with MR nodule grade significantly. • There were significant differences of D, f, and D{sup *} values among glands at grade 0–3. - Abstract: Purpose: To explore the correlation between intravoxel incoherent motion (IVIM) magnetic resonance (MR) parameters and MR nodular grade of parotid glands in patients with Sjögren’s syndrome (SS). Materials and methods: A total of 31 consecutive patients with SS and 28 gender- and age-matched healthy volunteers underwent bilateral parotid 3.0T MR examination including the IVIM sequence (9 b values, 0–800 s/mm{sup 2}). The apparent diffusion coefficient (ADC), diffusion coefficient D, pseudo-diffusion coefficient D{sup *}, and perfusion fraction f of bilateral parotid glands were obtained, and the nodular grade of each parotid gland was evaluated according to the MR morphological appearance. Results: Sixty-two parotid glands in 31 patients with SS consisted of 32, 14, 8, and 8 parotid glands at MR nodular grades 0, 1, 2, and 3, respectively. In parotid glands of grade 0, 1, 2, 3 and healthy volunteers, the ADC values were (1.13 ± 0.25, 1.11 ± 0.17, 1.05 ± 0.24, 0.89 ± 0.04 and 1.00 ± 0.21) × 10{sup −3} mm{sup 2}/s, D values were (0.92 ± 0.13, 0.90 ± 0.19, 0.90 ± 0.03, 0.67 ± 0.03, 0.81 ± 0.03) × 10{sup −3} mm{sup 2}/s, f values were 0.20 ± 0.04, 0.18 ± 0.02, 0.15 ± 0.01, 0.11 ± 0.01, 0.15 ± 0.06, and D{sup *}values were (53.89 ± 28.26, 41.78 ± 16.35, 51.24 ± 18.69, 31.83 ± 18.03, 36.83 ± 16.14) × 10{sup −3} mm{sup 2}/s respectively. The ADC, D, f, and D{sup *} values of parotid glands in patients with SS at grade 0 were significantly higher than those in healthy volunteers (all P < 0.05). Significant differences were observed in the D and f values of parotid glands in patients with SS among different grades (P = 0.003, < 0.001, respectively). The IVIM

  14. A meson-exchange isobar model for the {pi}{sup +}d {r_reversible} pp reaction

    Energy Technology Data Exchange (ETDEWEB)

    Canton, L.; Cattapan, G.; Dortmans, P.J.; Pisent, G. [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Svenne, J.P. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Physics]|[Winnipeg Inst. for Theoretical Physics, Winnipeg, MB (Canada)

    1994-10-10

    A broad set of observables are calculated for the {pi}{sup +} d {r_reversible} pp reaction with a relatively simple meson-exchange isobar model. The comparison between the calculated results and experimental data (including spin observables), shows that the model gives an overall phenomenologically acceptable description of the reaction around the {Delta} resonance. The effects due to the inclusion of Galilei invariant (pseudovector) recoil term in the {pi}NN vertex, of relativistic corrections to the {rho}-exchange component of the {Delta}N transition potential, and of NN final state interaction in the {pi}{sup +}d {yields} p+p process are also discussed. It is estimated that the model is sufficiently simple to be extended to the case of pion absorption on other light nuclei, in particular {sup 3}He (or tritium). 32 refs., 13 figs.

  15. Discovering the miR-26a-5p Targetome in Prostate Cancer Cells

    DEFF Research Database (Denmark)

    Rizzo, Milena; Berti, Gabriele; Russo, Francesco

    2017-01-01

    Purpose. miR-26a-5p is a tumor suppressor (TS) miRNA often downregulated in several tumor tissues and tumor cell lines. In this work, we performed the re-expression of the miR-26a-5p in DU-145 prostate cancer cells to collect genes interacting with miR-26a-5p and analyzed their integration...... in the tumorigenesis related pathways. Methods. The transfection of DU-145 prostate cancer cells with miR-26a-5p was done using nucleofection. The biological effects induced by miR-26a-5p re-expression were detected with routine assays for cell proliferation, cell cycle, survival, apoptosis and cell migration. The mi...... to integrate target genes in KEGG pathways and Protein-Protein Interaction networks (PPINs) and modules were built. Results. miR-26a-5p exerted an anti-proliferative effect acting at several levels, by decreasing survival and migration and inducing both cell cycle block and apoptosis. The analysis of the mi...

  16. Visit of H.E. Mr. Attila Chikan, Minister of Economic Affairs, Prof. Adam Török, President, National Committee for Technological Development, Mr. Pal Koncz, Deputy Director General, National Committee for Technological Development, Hungary

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    Visit of H.E. Mr. Attila Chikan, Minister of Economic Affairs, Prof. Adam Török, President, National Committee for Technological Development, Mr. Pal Koncz, Deputy Director General, National Committee for Technological Development, Hungary

  17. rändrat omhändertagande av patienter med uretärsten : - Lärdomar från ett förbättringsarbete

    OpenAIRE

    Khatami, Annelie

    2014-01-01

    Bakgrund: Omkring 10-15 % av befolkningen, oftast i arbetsför ålder, riskerar att någon gång drabbas av njursten. Nationella riktlinjer för njurstensbehandling saknas, men studier stödjer behandling inom 48 timmar för snabb symtomlindring och minskade besvärr patienten. Inom studerad verksamhet var tiden från diagnos till behandling lång och återinläggningarna var många, varför ett förbättringsarbete initierades. Syfte: Syftet med förbättringsarbetet var att halvera tiden från diagnos till...

  18. Static spherically symmetric wormholes in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, M.; Ahmad, Yasir [Institute Of Information Technology, Department of Mathematics, COMSATS, Lahore (Pakistan); Waheed, Saira [Prince Mohammad Bin Fahd University, Al Khobar (Saudi Arabia)

    2016-08-15

    In this work, we explore wormhole solutions in f(R, T) theory of gravity, where R is the scalar curvature and T is the trace of stress-energy tensor of matter. To investigate this, we consider a static spherically symmetric geometry with matter contents as anisotropic, isotropic, and barotropic fluids in three separate cases. By taking into account the Starobinsky f(R) model, we analyze the behavior of energy conditions for these different kinds of fluids. It is shown that the wormhole solutions can be constructed without exotic matter in few regions of space-time. We also give the graphical illustration of the results obtained and discuss the equilibrium picture for the anisotropic case only. It is concluded that the wormhole solutions with anisotropic matter are realistic and stable in this theory of gravity. (orig.)

  19. 10 CFR 26.406 - Fitness monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Fitness monitoring. 26.406 Section 26.406 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS FFD Program for Construction § 26.406 Fitness monitoring. (a...) Licensees and other entities shall implement a fitness monitoring program to deter substance abuse and...

  20. 10 CFR 26.413 - Review process.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Review process. 26.413 Section 26.413 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS FFD Program for Construction § 26.413 Review process. Licensees and other entities who implement an FFD program under this subpart shall establish and implement...

  1. Power-law cosmic expansion in f(R) gravity models

    International Nuclear Information System (INIS)

    Goheer, Naureen; Larena, Julien; Dunsby, Peter K. S.

    2009-01-01

    We show that within the class of f(R) gravity theories, Friedmann-Lemaitre-Robertson-Walker power-law perfect fluid solutions only exist for R n gravity. This significantly restricts the set of exact cosmological solutions which have similar properties to what is found in standard general relativity.

  2. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  3. Replication-defective lymphocytic choriomeningitis virus vectors expressing guinea pig cytomegalovirus gB and pp65 homologs are protective against congenital guinea pig cytomegalovirus infection.

    Science.gov (United States)

    Cardin, Rhonda D; Bravo, Fernando J; Pullum, Derek A; Orlinger, Klaus; Watson, Elizabeth M; Aspoeck, Andreas; Fuhrmann, Gerhard; Guirakhoo, Farshad; Monath, Thomas; Bernstein, David I

    2016-04-12

    Congenital cytomegalovirus infection can be life-threatening and often results in significant developmental deficits and/or hearing loss. Thus, there is a critical need for an effective anti-CMV vaccine. To determine the efficacy of replication-defective lymphocytic choriomeningitis virus (rLCMV) vectors expressing the guinea pig CMV (GPCMV) antigens, gB and pp65, in the guinea pig model of congenital CMV infection. Female Hartley strain guinea pigs were divided into three groups: Buffer control group (n = 9), rLCMV-gB group (n = 11), and rLCMV-pp65 (n = 11). The vaccines were administered three times IM at 1.54 × 10(6)FFU per dose at 21-day intervals. At two weeks after vaccination, the female guinea pigs underwent breeding. Pregnant guinea pigs were challenged SQ at ∼ 45-55 days of gestation with 1 × 10(5)PFU of GPCMV. Viremia in the dams, pup survival, weights of pups at delivery, and viral load in both dam and pup tissues were determined. Pup survival was significantly increased in the LCMV-gB vaccine group. There was 23% pup mortality in the gB vaccine group (p = 0.044) and 26% pup mortality in the pp65 vaccine group (p = 0.054) compared to 49% control pup mortality. The gB vaccine induced high levels of gB binding and detectable neutralizing antibodies, reduced dam viremia, and significantly reduced viral load in dam tissues compared to control dams (p < 0.03). Reduced viral load and transmission in pups born to gB-vaccinated dams was observed compared to pups from pp65-vaccinated or control dams. The rLCMV-gB vaccine significantly improved pup survival and also increased pup weights and gestation time. The gB vaccine was also more effective at decreasing viral load in dams and pups and limiting congenital transmission. Thus, rLCMV vectors that express CMV antigens may be an effective vaccine strategy for congenital CMV infection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. MR study of acute myocardial infarction with injection of Gd-DOTA (Fifteen patients)

    International Nuclear Information System (INIS)

    Richoz, B.; Delcour, C.; Depelchin, P.; Lenaers, A.; Jacquemin, C.; Gusella, P.; Struyven, J.; Richoz, B.

    1990-01-01

    We studied 15 patients 4 to 8 days after myocardial infarction by using ECG gated MR before and after administration of 0.2 mmol/kg Gd-DOTA. The diagnosis in each patient was confirmed by electrocardiographic criteria, elevated levels of fractionated creatine kinase (CK) isoenzyme, thallium scintigraphy, ventriculography and coronarography. T1-weighted, spin-echo images, were obtained before and immediately after injection of Gd-DOTA and were repeated 15 min later. The site of infarction was visualized in 10 patients as an area of high signal intensity after the injection of Gd-DOTA. Contrast between normal and infarcted myocardium was greatest 15 min after injection. Three patients were excluded because of failure to acquire adequate MR studies. In 2 other patients, the infarct were not detected. Before injection of Gd-DOTA, only 2 infarcts were detected. These results suggest that Gd-DOTA can improve MR visualization and detection of acute myocardial infarction [fr

  5. Satish R Shetye

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. Satish R Shetye. Articles written in Resonance – Journal of Science Education. Volume 10 Issue 2 February 2005 pp 8-19 General Article. Tsunamis - A Large-Scale Earth and Ocean Phenomenon · Satish R Shetye · More Details Fulltext PDF ...

  6. The simplest non-minimal matter-geometry coupling in the f(R, T) cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, P.H.R.S. [ITA - Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Paulo (Brazil); Sahoo, P.K. [Birla Institute of Technology and Science-Pilani, Department of Mathematics, Hyderabad (India)

    2017-07-15

    f(R, T) gravity is an extended theory of gravity in which the gravitational action contains general terms of both the Ricci scalar R and the trace of the energy-momentum tensor T. In this way, f(R, T) models are capable of describing a non-minimal coupling between geometry (through terms in R) and matter (through terms in T). In this article we construct a cosmological model from the simplest non-minimal matter-geometry coupling within the f(R, T) gravity formalism, by means of an effective energy-momentum tensor, given by the sum of the usual matter energy-momentum tensor with a dark energy contribution, with the latter coming from the matter-geometry coupling terms. We apply the energy conditions to our solutions in order to obtain a range of values for the free parameters of the model which yield a healthy and well-behaved scenario. For some values of the free parameters which are submissive to the energy conditions application, it is possible to predict a transition from a decelerated period of the expansion of the universe to a period of acceleration (dark energy era). We also propose further applications of this particular case of the f(R, T) formalism in order to check its reliability in other fields, rather than cosmology. (orig.)

  7. The simplest non-minimal matter-geometry coupling in the f(R, T) cosmology

    International Nuclear Information System (INIS)

    Moraes, P.H.R.S.; Sahoo, P.K.

    2017-01-01

    f(R, T) gravity is an extended theory of gravity in which the gravitational action contains general terms of both the Ricci scalar R and the trace of the energy-momentum tensor T. In this way, f(R, T) models are capable of describing a non-minimal coupling between geometry (through terms in R) and matter (through terms in T). In this article we construct a cosmological model from the simplest non-minimal matter-geometry coupling within the f(R, T) gravity formalism, by means of an effective energy-momentum tensor, given by the sum of the usual matter energy-momentum tensor with a dark energy contribution, with the latter coming from the matter-geometry coupling terms. We apply the energy conditions to our solutions in order to obtain a range of values for the free parameters of the model which yield a healthy and well-behaved scenario. For some values of the free parameters which are submissive to the energy conditions application, it is possible to predict a transition from a decelerated period of the expansion of the universe to a period of acceleration (dark energy era). We also propose further applications of this particular case of the f(R, T) formalism in order to check its reliability in other fields, rather than cosmology. (orig.)

  8. De los Estados fallidos a los Estados frágiles: un reto para el Derecho internacional contemporáneo [RECENSIÓN

    OpenAIRE

    Ortiz-Hernández, E. (Eimys)

    2013-01-01

    Recensión de Garciandía Garmendia, R., De los Estados fallidos a los Estados frágiles: un reto para el Derecho internacional contemporáneo Ed. Comares, Granada, 2013, 294 pp. (ISBN: 978-84-9045-054-3)

  9. Clinical estimation of myocardial infarct volume with MR imaging

    International Nuclear Information System (INIS)

    Johns, J.A.; Leavitt, M.B.; Field, B.D.; Yasuda, T.; Gold, H.; Leinbach, R.C.; Brady, T.J.; Dinsmore, R.E.

    1987-01-01

    MR imaging has not previously been used to assess infarct size in humans. Short-axis spin-echo cardiac MR imaging was performed in 20 patients who had undergone intravenous thrombolytic therapy and angiography, 10 days after myocardial infarct. A semi-automated computer program was used to outline the infarct region on each section. The outlines were algorithmically stacked and a three-dimensional representation of the infarct was created. The MR imaging infarct volume was then computed using the Simpson rule. Comparison with ventriculographic infarct size as determined by the computed severely hypokinetic segment length showed excellent correlation (r = .84, P < .001)

  10. miR-26a suppresses autophagy in swine Sertoli cells by targeting ULK2.

    Science.gov (United States)

    Ran, M; Li, Z; Cao, R; Weng, B; Peng, F; He, C; Chen, B

    2018-05-14

    A large number of microRNAs (miRNAs) have been detected from porcine testicular tissues thanks to the development of high-throughput sequencing technology. However, the regulatory roles of most identified miRNAs in swine testicular development or spermatogenesis are poorly understood. In our previous study, ULK2 (uncoordinated-51-like kinase 2) was predicted as a target gene of miR-26a. In this study, we aimed to investigate the role of miR-26a in swine Sertoli cell autophagy. The relative expression of miR-26a and ULK2 levels has a significant negative correlation (R 2  = .5964, p ≤ .01) in nine developmental stages of swine testicular tissue. Dual-luciferase reporter assay results show that miR-26a directly targets the 3'UTR of the ULK2 gene (position 618-624). In addition, both the mRNA and protein expression of ULK2 were downregulated by miR-26a in swine Sertoli cells. These results indicate that miR-26a targets the ULK2 gene and downregulates its expression in swine Sertoli cells. Based on the expression of marker genes (LC3, p62 and Beclin-1), overexpression of miR-26a or knock-down of ULK2 inhibits swine Sertoli cell autophagy. Taken together, these findings demonstrate that miR-26a suppresses autophagy in swine Sertoli cells by targeting ULK2. © 2018 Blackwell Verlag GmbH.

  11. Compact stars in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Das, Amit; Guha, B.K. [Indian Institute of Engineering Science and Technology, Department of Physics, Howrah, West Bengal (India); Rahaman, Farook [Jadavpur University, Department of Mathematics, Kolkata, West Bengal (India); Ray, Saibal [Government College of Engineering and Ceramic Technology, Department of Physics, Kolkata, West Bengal (India)

    2016-12-15

    In the present paper we generate a set of solutions describing the interior of a compact star under f(R, T) theory of gravity which admits conformal motion. An extension of general relativity, the f(R, T) gravity is associated to Ricci scalar R and the trace of the energy-momentum tensor T. To handle the Einstein field equations in the form of differential equations of second order, first of all we adopt the Lie algebra with conformal Killing vectors (CKV) which enable one to get a solvable form of such equations and second we consider the equation of state (EOS) p = ωρ with 0 < ω < 1 for the fluid distribution consisting of normal matter, ω being the EOS parameter. We therefore analytically explore several physical aspects of the model to represent behavior of the compact stars such as - energy conditions, TOV equation, stability of the system, Buchdahl condition, compactness and redshift. It is checked that the physical validity and the acceptability of the present model within the specified observational constraint in connection to a dozen of the compact star candidates are quite satisfactory. (orig.)

  12. Brane f(R) gravity and the dark side of the universe

    International Nuclear Information System (INIS)

    Borzou, A.; Sepangi, H. R.; Shahidi, S.; Yousefi, R.

    2009-01-01

    We consider a brane world scenario in which the bulk action is assumed to have the form of a generic function of the Ricci scalar f(R) and derive the resulting Einstein field equation on the brane. In a constant curvature bulk a conserved geometric quantity appears in the field equations which can be associated with matter. We present spherically symmetric solutions which account for galaxy rotation curves in a specific form. Then cosmological solutions by assuming a specific form for f(R) are derived which can explain an accelerated expanding universe.

  13. Study of some chaotic inflationary models in f(R) gravity

    Science.gov (United States)

    Sharif, M.; Nawazish, Iqra

    2018-04-01

    In this paper, we discuss an inflationary scenario via scalar field and fluid cosmology for an anisotropic homogeneous universe model in f(R) gravity. We consider an equation of state which corresponds to a quasi-de Sitter expansion and investigate the effect of the anisotropy parameter for different values of the deviation parameter. We evaluate potential models like linear, quadratic and quartic models which correspond to chaotic inflation. We construct the observational parameters for a power-law model of f(R) gravity and construct the graphical analysis of tensor-scalar ratio and spectral index which indicates the consistency of these parameters with Planck 2015 data.

  14. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  15. Revisiting van der Waals like behavior of f(R AdS black holes via the two point correlation function

    Directory of Open Access Journals (Sweden)

    Jie-Xiong Mo

    2017-05-01

    Full Text Available Van der Waals like behavior of f(R AdS black holes is revisited via two point correlation function, which is dual to the geodesic length in the bulk. The equation of motion constrained by the boundary condition is solved numerically and both the effect of boundary region size and f(R gravity are probed. Moreover, an analogous specific heat related to δL is introduced. It is shown that the T−δL graphs of f(R AdS black holes exhibit reverse van der Waals like behavior just as the T−S graphs do. Free energy analysis is carried out to determine the first order phase transition temperature T⁎ and the unstable branch in T−δL curve is removed by a bar T=T⁎. It is shown that the first order phase transition temperature is the same at least to the order of 1010 for different choices of the parameter b although the values of free energy vary with b. Our result further supports the former finding that charged f(R AdS black holes behave much like RN-AdS black holes. We also check the analogous equal area law numerically and find that the relative errors for both the cases θ0=0.1 and θ0=0.2 are small enough. The fitting functions between log⁡|T−Tc| and log⁡|δL−δLc| for both cases are also obtained. It is shown that the slope is around 3, implying that the critical exponent is about 2/3. This result is in accordance with those in former literatures of specific heat related to the thermal entropy or entanglement entropy.

  16. Pulmonary branch arterial flow can be measured with cine MR velocity mapping

    International Nuclear Information System (INIS)

    Caputo, G.R.; Kondo, C.; Masui, T.; Foster, E.; Geraci, S.J.; O'Sullivan, M.; Higgins, C.B.

    1990-01-01

    This paper assesses the capability of cine MR phase velocity mapping (CVM) to measure main, right-sided, and left-sided pulmonary arterial (PA) blood flow. The authors examined a constant-flow phantom and nine healthy volunteers with use of 1.5-T MR imaging system (GE Signa) with phase velocity cine sequences. CVM correctly measured constant-flow phantom velocities (range, 20-190 cm/sec; r = .998, SEE = 4.2 cm/sec), and velocity with use of angulated planes to section the phantom tube perpendicularly. CVM peak systolic main PA velocity (79 cm/sec ± 10) correlated well with Doppler US measurements (80 cm/sec ± 7). CVM main PA flow correlated well with conventional cine MR LV stroke volume measurements (r = .98, SEE = 4.8 mL). Left and right PA flow on the angulated planes were 29 mL ± 7 and 34 mL ± 10, respectively

  17. Evaluating item endorsement rates for the MMPI-2-RF F-r and Fp-r scales across ethnic, gender, and diagnostic groups with a forensic inpatient sample.

    Science.gov (United States)

    Glassmire, David M; Jhawar, Amandeep; Burchett, Danielle; Tarescavage, Anthony M

    2017-05-01

    The Minnesota Multiphasic Personality Inventory-2 (MMPI-2) F(p) (Infrequency-Psychopathology) scale was developed to measure overreporting in a manner that was minimally confounded by genuine psychopathology, which was a problem with using the MMPI-2 F (Infrequency) scale among patients with severe mental illness. Although revised versions of both of these scales are included on the MMPI-2-Restructured Form and used in a forensic context, no item-level research has been conducted on their sensitivity to genuine psychopathology among forensic psychiatric inpatients. Therefore, we examined the psychometric properties of the scales in a sample of 438 criminally committed forensic psychiatric inpatients who were adjudicated as not guilty by reason of insanity and had no known incentive to overreport. We found that 20 of the 21 Fp-r items (95.2%) demonstrated endorsement rates ≤ 20%, with 14 of the items (66.7%) endorsed by less than 10% of the sample. Similar findings were observed across genders and across patients with mood and psychotic disorders. The one item endorsed by more than 20% of the sample had a 23.7% overall endorsement rate and significantly different endorsement rates across ethnic groups, with the highest endorsements occurring among Hispanic/Latino (43.3% endorsement rate) patients. Endorsement rates of F-r items were generally higher than for Fp-r items. At the scale level, we also examined correlations with the Restructured Clinical Scales and found that Fp-r demonstrated lower correlations than F-r, indicating that Fp-r is less associated with a broad range of psychopathology. Finally, we found that Fp-r demonstrated slightly higher specificity values than F-r at all T score cutoffs. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Acute interstitial edematous pancreatitis: Findings on non-enhanced MR imaging

    Science.gov (United States)

    Zhang, Xiao-Ming; Feng, Zhi-Song; Zhao, Qiong-Hui; Xiao, Chun-Ming; Mitchell, Donald G; Shu, Jian; Zeng, Nan-Lin; Xu, Xiao-Xue; Lei, Jun-Yang; Tian, Xiao-Bing

    2006-01-01

    AIM: To study the appearances of acute interstitial edematous pancreatitis (IEP) on non-enhanced MR imaging. METHODS: A total of 53 patients with IEP diagnosed by clinical features and laboratory findings were underwent MR imaging. MR imaging sequences included fast spoiled gradient echo (FSPGR) fat saturation axial T1-weighted imaging, gradient echo T1-weighted (in phase), single shot fast spin echo (SSFSE) T2-weighted, respiratory triggered (R-T) T2-weighted with fat saturation, and MR cholangiopancreatography. Using the MR severity score index, pancreatitis was graded as mild (0-2 points), moderate (3-6 points) and severe (7-10 points). RESULTS: Among the 53 patients, IEP was graded as mild in 37 patients and as moderate in 16 patients. Forty-seven of 53 (89%) patients had at least one abnormality on MR images. Pancreas was hypointense relative to liver on FSPGR T1-weighted images in 18.9% of patients, and hyperintense in 25% and 30% on SSFSE T2-weighted and R-T T2-weighted images, respectively. The prevalences of the findings of IEP on R-T T2-weighted images were, respectively, 85% for pancreatic fascial plane, 77% for left renal fascial plane, 55% for peripancreatic fat stranding, 42% for right renal fascial plane, 45% for perivascular fluid, 40% for thickened pancreatic lobular septum and 25% for peripancreatic fluid, which were markedly higher than those on in-phase or SSFSE T2-weighted images (P fluid. R-T T2-weighted imaging is more sensitive than in-phase and SSFSE T2-weighted imaging for depicting IEP. PMID:17007053

  19. Importprocessen för inrednings- och gåvoartiklar från USA till Finland : En handbok för företagaren

    OpenAIRE

    Smeds, Desiré; Backlund, Johanna

    2016-01-01

    Det här examensarbetet handlar om import från USA med fokus på inrednings- och gåvoartiklar. I arbetet lyfter vi steg för steg fram de delar som utgör importprocessen hela vägen från hur man hittar en pålitlig leverantör till förtullningen av produkterna här i Finland. Syftet med arbetet är att det skall kunna fungera som en handbok för företag som vill starta en småskalig importverksamhet av inrednings- och gåvoartiklar. Vi tar även upp information om import och internationell handel i a...

  20. 78 FR 25302 - Notice of Realty Action: Termination of Recreation and Public Purposes Act Classifications and...

    Science.gov (United States)

    2013-04-30

    ... generally, including the 1872 Mining Law. The classification termination and opening order will affect 30... Register (52 FR 44492) announcing the classification of 20 acres of public land under its jurisdiction as... jurisdiction as suitable for lease/disposal pursuant to the R&PP Act. Upon classification, the BLM leased the...

  1. Wormholes in viable f(R) modified theories of gravity and weak energy condition

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Petar [Universitaet Hamburg, II. Institut fuer Theoretische Physik, Hamburg (Germany); Sossich, Marko [University of Zagreb, Department of Physics, Faculty of Electrical Engineering and Computing, Zagreb (Croatia)

    2015-03-01

    In this work wormholes in viable f(R) gravity models are analyzed. We are interested in exact solutions for stress-energy tensor components depending on different shape and redshift functions. Several solutions of gravitational equations for different f(R) models are examined. The solutions found imply no need for exotic material, while this need is implied in the standard general theory of relativity. A simple expression for weak energy condition (WEC) violation near the throat is derived and analyzed. High curvature regime is also discussed, as well as the question of the highest possible values of the Ricci scalar for which the WEC is not violated near the throat, and corresponding functions are calculated for several models. The approach here differs from the one that has been common since no additional assumptions to simplify the equations have been made, and the functions in f(R) models are not considered to be arbitrary functions, but rather a feature of the theory that has to be evaluated on the basis of consistency with observations for the Solar System and cosmological evolution. Therefore in this work we show that the existence of wormholes without exotic matter is not only possible in simple arbitrary f(R) models, but also in models that are in accordance with empirical data. (orig.)

  2. MR imaging in chronic epicondylitis humeri radialis at 1.0 T: is Gd-DTPA administration useful?

    International Nuclear Information System (INIS)

    Herber, S.; Kalden, P.; Kreitner, K.-F.; Thelen, M.

    2001-01-01

    Purpose: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. Material and Methods: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 elbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistant pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T 2 -weighted, fat-supressed TSE sequence, and a flash-2-D sequence. Also, fat-supressed, T 1 -weighted SE sequences before and after administration of Gd-DTPA contrast media have been recorded. Results: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendom. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondylus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. Conclusion: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information. (orig.) [de

  3. 10 CFR 26.155 - Laboratory personnel.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Laboratory personnel. 26.155 Section 26.155 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories Certified by the Department of Health and Human... ensure the continued competency of laboratory personnel by documenting their in-service training...

  4. M&R Holdings, LLC d/b/a Brandon’s Reserve Residential Development - Clean Water Act Public Notice

    Science.gov (United States)

    The EPA is providing notice of an Administrative Penalty Assessment in the form of an Expedited Storm Water Settlement Agreement against M&R Holdings, LLC d/b/a Brandon’s Reserve Residential Development, a business located at 15602 Wilden Drive, Urbandale,

  5. 10 CFR 26.35 - Employee assistance programs.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Employee assistance programs. 26.35 Section 26.35 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Program Elements § 26.35 Employee assistance... to safely and competently perform their duties. Employee assistance programs must be designed to...

  6. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    Science.gov (United States)

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2

  7. Dysembryoplastic neuroepithelial tumors: proton MR spectroscopy, diffusion and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Bulakbasi, Nail; Kocaoglu, Murat; Sanal, Tuba H.; Tayfun, Cem [Gulhane Military Medical Academy, Department of Radiology, Military Medical Faculty, Ankara (Turkey)

    2007-10-15

    We describe the magnetic resonance (MR) imaging characteristics of dysembryoplastic neuroepithelial tumors (DNT) and discuss their differential diagnosis. Proton MR spectroscopy (TE 30 and 136 ms), diffusion-weighted and perfusion images were retrospectively evaluated in 22 patients with pathologically proven DNT (17 male and 5 female, mean age 18.7 years) and 14 control subjects (10 male and 4 female, mean age 16.9 years). The results from the DNT patients and from the control subjects were compared using an independent sample t-test and the degree of correlation was tested by Pearson's correlation. All DNTs were solitary and in a supratentorial cortical or subcortical location (ten temporal, eight frontal and four parietal). They had low-signal on T1-weighted images and high-signal on T2-weighted images without a prominent mass effect. Additionally a cystic appearance (six patients, 27.3%), cortical dysplasia (six patients, 27.3%) and contrast enhancement (four patients, 18.2%) were also noted. No significant differences were detected in NAA/Cho, NAA/Cr, NAA/Cho+Cr or Cho/Cr ratios between DNT and normal brain. DNTs had a significantly higher mI/Cr ratio and apparent diffusion coefficient (ADC) values and lower cerebral blood values than normal parenchyma (P < 0.001). ADC had the highest correlation with the diagnosis of DNT (r = 0.996) followed by relative cerebral blood volume (rCBV) (r = -0.883) and mI/Cr ratio (r = 0.663). Proton MR spectroscopy, diffusion-weighted and perfusion imaging characteristics of DNTs provide additional information to their MR imaging findings. The MR spectrum showing a slight increase in mI/Cr ratio, and higher ADC and lower rCBV values than normal parenchyma help to differentiate DNTs from other cortical tumors, which had higher rCBV and lower ADC values than DNTs. (orig.)

  8. shukla r k

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics. SHUKLA R K. Articles written in Pramana – Journal of Physics. Volume 86 Issue 5 May 2016 pp 1099-1105 Regular. A comparative study of the density of defect states in bulk samples and thin films of glassy Se 90 Sb 10 · KUMAR ANJANI DWIVEDI PRABHAT K SHUKLA R K ...

  9. Seymour Benzer and T4 rII

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 13; Issue 10. Seymour Benzer and T4 rII - Running the Map into the Ground. R Jayaraman. General Article Volume 13 Issue 10 October 2008 pp 898-908. Fulltext. Click here to view fulltext PDF. Permanent link:

  10. 10 CFR 26.189 - Determination of fitness.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Determination of fitness. 26.189 Section 26.189 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Determining Fitness-for-Duty Policy Violations and Determining Fitness § 26.189 Determination of fitness. (a) A determination of fitness is the process entered...

  11. MiR-26a enhances invasive capacity by suppressing GSK3β in human lung cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Gaoyang; Liu, Boning [Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenviroment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin 300052 (China); Meng, Zhaowei [Department of Nuclear Medicine, Tianjin Medical University General Hospital, Tianjin 300052 (China); Liu, Yunde [School of Laboratory Medicine, Tianjin Medical University, Tianjin 300052 (China); Li, Xuebing [Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenviroment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin 300052 (China); Wu, Xiang [Core Facility Center, Tianjin Medical University General Hospital, Tianjin 300052 (China); Zhou, Qinghua [Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenviroment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin 300052 (China); Xu, Ke, E-mail: ke_xu@hotmail.com [Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenviroment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin 300052 (China)

    2017-03-15

    Lung cancer is the common cause of death from cancer, and most lung cancer patients die of metastasis. MicroRNAs (miRNAs) function as either oncogenes or tumor suppressors, playing crucial role not only in tumorigenesis, but also in tumor invasion and metastasis. There are several studies showed that miR-26a is involved in carcinogenesis, however, its role in tumor metastasis need to be elucidated. In this study, we showed that ectopic expression of miR-26a enhanced migration and invasion of lung cancer cells. Glycogen synthase kinase-3β (GSK3β) was identified as a direct target of miR-26a. GSK3β expression negatively correlated with miR-26a expression in lung cancer tissues. Silencing of GSK3β achieved similar effect as miR-26a over-expression; over-expression of GSK3β reversed the enhanced effect of miR-26a on lung cancer cell migration and invasion. Further study indicated that miR-26a increased β-catenin expression and nuclear translocation. C-myc and cyclin D1, the downstream genes of β-catenin, were also up-regulated by miR-26a. Furthermore, xenograft study showed that miR-26a promoted lung cancer cell growth in vivo, and suppressed GSK3β expression. Collectively, our results demonstrated that miR-26a enhanced metastatic potential of lung cancer cells via activation of β-catenin pathway by targeting GSK3β, suggesting the potential applicability of miR-26a as a target for cancer treatment. - Highlights: • miR-26a enhances migration and invasion of lung cancer cells. • GSK3β is identified as a direct target of miR-26a. • miR-26a activates β-catenin pathway by targeting GSK3β. • miR-26a promotes lung cancer cell growth in vivo.

  12. MiR-26a enhances invasive capacity by suppressing GSK3β in human lung cancer cells

    International Nuclear Information System (INIS)

    Lin, Gaoyang; Liu, Boning; Meng, Zhaowei; Liu, Yunde; Li, Xuebing; Wu, Xiang; Zhou, Qinghua; Xu, Ke

    2017-01-01

    Lung cancer is the common cause of death from cancer, and most lung cancer patients die of metastasis. MicroRNAs (miRNAs) function as either oncogenes or tumor suppressors, playing crucial role not only in tumorigenesis, but also in tumor invasion and metastasis. There are several studies showed that miR-26a is involved in carcinogenesis, however, its role in tumor metastasis need to be elucidated. In this study, we showed that ectopic expression of miR-26a enhanced migration and invasion of lung cancer cells. Glycogen synthase kinase-3β (GSK3β) was identified as a direct target of miR-26a. GSK3β expression negatively correlated with miR-26a expression in lung cancer tissues. Silencing of GSK3β achieved similar effect as miR-26a over-expression; over-expression of GSK3β reversed the enhanced effect of miR-26a on lung cancer cell migration and invasion. Further study indicated that miR-26a increased β-catenin expression and nuclear translocation. C-myc and cyclin D1, the downstream genes of β-catenin, were also up-regulated by miR-26a. Furthermore, xenograft study showed that miR-26a promoted lung cancer cell growth in vivo, and suppressed GSK3β expression. Collectively, our results demonstrated that miR-26a enhanced metastatic potential of lung cancer cells via activation of β-catenin pathway by targeting GSK3β, suggesting the potential applicability of miR-26a as a target for cancer treatment. - Highlights: • miR-26a enhances migration and invasion of lung cancer cells. • GSK3β is identified as a direct target of miR-26a. • miR-26a activates β-catenin pathway by targeting GSK3β. • miR-26a promotes lung cancer cell growth in vivo.

  13. 10 CFR 26.169 - Reporting Results.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Reporting Results. 26.169 Section 26.169 Energy NUCLEAR... specific gravity test. (4) For a specimen that has an invalid result, the laboratory shall contact the MRO... transmission and ensure only authorized access to any data transmission, storage, and retrieval system. (f) For...

  14. Clinical investigation on application of water swallowing to MR esophagography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jinping, E-mail: zjpmri@163.com [Department of Radiology, Tongling People' s Hospital, Bijiashan Road 468, Tongling 244000, Anhui (China); Hu, Weijian; Zang, Lin [Department of Cardiothoracic Surgery, Tongling People' s Hospital, Bijiashan Road 468, Tongling 244000, Anhui (China); Yao, Yibin; Tang, Yongxiang; Qian, Zhen; Gao, Ping; Wu, Xiaoyan; Li, Shijian [Department of Radiology, Tongling People' s Hospital, Bijiashan Road 468, Tongling 244000, Anhui (China); Xie, Zhenlan; Yuan, Xiaoqing [Department of Pathology, Tongling People' s Hospital, Bijiashan Road 468, Tongling 244000, Anhui (China)

    2012-09-15

    Objective: To verify the clinical outcomes of applying water swallowing to MR esophagography. Methods: Thirty patients confirmed postoperatively or histopathologically with thoracic esophageal carcinoma by endoscopic biopsy and 10 healthy volunteers with normal esophagus underwent respectively conventional magnetic resonance imaging (MRI) detection and water swallowing MR esophagography. Of those patients, 4 underwent second examination after radiotherapy. Assessment on imaging effects of MR esophagography was performed. Assessment on definition on MR esophagography of the tumor in both upper and lower ends, specific localization, tumor size finally measured, coincidence with the gross pathologic types and tumor staging were respectively performed by comparison with conventional MRI. Additionally, we evaluated the outcomes of radiotherapy by comparing the previous MR esophagography with the second one with interventional technique. Results: Of the total 44 images of MR esophagography, 97.7% (43/44) were in high resolution by sagittal view and 81.8% (36/44) by cross-section. 93.3% (56/60) of the MR esophagography were clearly defined with the neoplastic lesion ends in the 30 patients with thoracic esophageal carcinoma, compared with 11.7% (7/60) by conventional MRI. The results were totally different in statistics (P < 0.005). Preoperative conventional MRI detection of the 22 cases in 25 undergone radical resection suggested vague diameter of the primary tumor and impossibly identified it at middle-lower thoracic esophagus in 5, and even failed to confirm gross pathologic types in 19 cases. Yet, MR esophagography with water swallowing represented accurate tumor length (graded as excellent) in 88% (22/25), localization in 100% (25/25), exact gross pathologic types in 88% (22/25), and accuracy for tumor staging in 80.8% (21/26) compared to 92.3% (24/26) by conventional MRI. Therapeutic effects achieved in 4 patients with radiotherapy. Conclusions: MR esophagography

  15. 10 CFR 26.168 - Blind performance testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Blind performance testing. 26.168 Section 26.168 Energy... and Human Services § 26.168 Blind performance testing. (a) Each licensee and other entity shall submit blind performance test samples to the HHS-certified laboratory. (1) During the initial 90-day period of...

  16. Mycobacterium tuberculosis decreases human macrophage IFN-γ responsiveness through miR-132 and miR-26a.

    Science.gov (United States)

    Ni, Bin; Rajaram, Murugesan V S; Lafuse, William P; Landes, Michelle B; Schlesinger, Larry S

    2014-11-01

    IFN-γ-activated macrophages play an essential role in controlling intracellular pathogens; however, macrophages also serve as the cellular home for the intracellular pathogen Mycobacterium tuberculosis. Based on previous evidence that M. tuberculosis can modulate host microRNA (miRNA) expression, we examined the miRNA expression profile of M. tuberculosis-infected primary human macrophages. We identified 31 differentially expressed miRNAs in primary human macrophages during M. tuberculosis infection by NanoString and confirmed our findings by quantitative real-time RT-PCR. In addition, we determined a role for two miRNAs upregulated upon M. tuberculosis infection, miR-132 and miR-26a, as negative regulators of transcriptional coactivator p300, a component of the IFN-γ signaling cascade. Knockdown expression of miR-132 and miR-26a increased p300 protein levels and improved transcriptional, translational, and functional responses to IFN-γ in human macrophages. Collectively, these data validate p300 as a target of miR-132 and miR-26a, and demonstrate a mechanism by which M. tuberculosis can limit macrophage responses to IFN-γ by altering host miRNA expression. Copyright © 2014 by The American Association of Immunologists, Inc.

  17. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  18. Study on GIF PR/PP evaluation methodology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B. H.; Kwon, E. H.; Kim, H. D. [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    Proliferation resistance (PR) and physical protection (PP) is one of the four technology goals of generation IV nuclear energy systems (NESs). The PR component of the goal focuses on providing strong assurance that generation IV NESs are the least desirable sources for the diversion or undeclared production of nuclear materials, whereas the PP portion of the goal ensures that generation IV NESs are robust against theft and sabotage. In 2002, the road map of the Generation IV International Forum (GIF) envisioned that the R and D program for PR and PP would have three areas: 1) safeguards and physical protection technology R and D for each GIF system; 2) formulation of PR and PP criteria and metrics; and 3) evaluation of the criteria and metrics. To cover these R and D items, the PR and PP Working Group (PRPPWG) was formed in late 2002 and has since developed a methodology for PR and PP evaluation. In a succession of revisions beginning in 2004, consensus was achieved amongst all participating GIF countries and related organizations (i.e., IAEA and EU), and Revision 6 of the methodology report was approved by GIF for open distribution in 2011. The paper describes in detail the methodology developed by the PRPPWG and discusses its applicability to the sodium-cooled fast reactor (SFR) fuel cycle with pyro processing currently under development in Korea.

  19. Perfusion MR imaging of the heart with TrueFISP

    International Nuclear Information System (INIS)

    Schreiber, W.G.; Schmitt, M.; Kalden, P.; Mohrs, O.; Kreitner, K.F.; Thelen, M.; Horstick, G.; Gumbrich, T.; Petersen, S.; Voigtlaender, T.

    2001-01-01

    Objective: Development and test of a saturation-recovery TrueFISP (SR-Trufi) pulse sequence for myocardial perfusion MR imaging (MRI) using improved gradient hardware. Material and methods: Measurements were performed on a 1.5 T scanner with prototype gradients (50 mT/m, minimum rise time 300 μs). T 1 -weighted first-pass MRI of Gd-DTPA (0.025 μmol/kg) kinetics in the myocardium was performed using an SR-Trufi pulse sequence (T R /T E /α=2.6 ms/1.4 ms/55 ) with a saturation preparation of TD-30 ms before the TrueFISP readout. Measurements were performed in volunteers (n=4) and in a pig model of chronic ischemia (n=1). Results: In phantoms, the signal intensity was linear with contrast concentration up to 0.9 mmol/kg Gd-DTPA. MR images obtained with SR-Trufi had a good image quality and high spatial resolution of 2.1 mmx2.1 mm. Differences of the contrast agent's kinetics between a subendocardial perfusion deficit and neighboring myocardium were well visible on both MR images and signal-time curves derived from the region-of-interest analysis. Conclusion: SR-Trufi appears to be an interesting new technique for the assessment of myocardial microcirculation using dedicated cardiovascular MR systems. (orig.) [de

  20. Evaluation of thermometric monitoring for intradiscal laser ablation in an open 1.0 T MR scanner.

    Science.gov (United States)

    Wonneberger, Uta; Schnackenburg, Bernhard; Wlodarczyk, Waldemar; Rump, Jens; Walter, Thula; Streitparth, Florian; Teichgräber, Ulf Karl Mart

    2010-01-01

    The purpose of this study was to evaluate different methods of magnetic resonance thermometry (MRTh) for the monitoring of intradiscal laser ablation therapy in an open 1.0 Tesla magnetic resonance (MR) scanner. MRTh methods based on the two endogenous MR temperature indicators of spin-lattice relaxation time T1 and water proton resonance frequency (PRF) shift were optimised and compared in vitro. For the latter, we measured the effective spin-spin relaxation times T2* in intervertebral discs of volunteers. Then we compared four gradient echo-based imaging techniques to monitor laser ablations in human disc specimens. Criteria of assessment were outline of anatomic detail, immunity against needle artefacts, signal-to-noise ratio (SNR) and accuracy of the calculated temperature. T2* decreased in an inverse and almost linear manner with the patients' age (r = 0.9) from 70 to 30 ms (mean of 49 ms). The optimum image quality (anatomic details, needle artefacts, SNR) and temperature accuracy (+/-1.09 degrees C for T1-based and +/-1.11 degrees C for PRF-based MRTh) was achieved with a non-spoiled gradient-echo sequence with an echo time of TE = 10 ms. Combination of anatomic and thermometric non-invasive monitoring of laser ablations in the lumbar spine is feasible. The temperature accuracy of the investigated T1- and PRF-based MRTh methods in vitro is high enough and promises to be reliable in vivo as well.

  1. 26 CFR 1.46-10 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true [Reserved] 1.46-10 Section 1.46-10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Rules for Computing Credit for Investment in Certain Depreciable Property § 1.46-10 [Reserved] ...

  2. Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

    Science.gov (United States)

    Berg, W A; Caskey, C I; Hamper, U M; Kuhlman, J E; Anderson, N D; Chang, B W; Sheth, S; Zerhouni, E A

    1995-10-01

    To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

  3. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR

  4. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  5. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  6. Significance of MR imaging in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Frank, H.; Globits, S.; Mayr, H.; Lang, I.; Kneussl, M.; Glogar, D.; Miczoch, J.; Neuhold, A.; Imhof, H.

    1989-01-01

    To determine the diagnostic impact of MR imaging in pulmonary hypertension (PH), the authors have examined 12 PH patients with a 0.5- or 1.5-T magnet in a double-angulation projection with multisection, multiphase technique and a gradient-echo sequence. MR data were evaluated for right ventricular volumes or function and compared with data from 10 control subjects. In PH patients, MR imaging showed right ventricular enlargement with hypertrophy, right atrial enlargement, and abnormal septal motion. Right ventricular (RV) function was compromised, with reduced RV circumferential shortening. PH patients had a severe reduction of long-axis shortening and variable reduction of short-axis shortening that correlated with the degree of PH (r = .68, P <.01)

  7. 76 FR 10940 - Notice of Delays in Processing of Special Permits Applications

    Science.gov (United States)

    2011-02-28

    ... Industrial Packaging 4 03-31-2011 Assoc., Washington, DC. 14839-N Matheson Tri-Gas, Inc., Basking 3 11-30-2010 Ridge, NJ. 14868-N Wal-Mart Stores, Inc., 4 03-31-2011 Bentonville, AR. 14878-N Humboldt County...

  8. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  9. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  10. MR imaging of kidneys: functional evaluation using F-15 perfusion imaging

    International Nuclear Information System (INIS)

    Grattan-Smith, J. Damien; Jones, Richard A.; Little, Stephen; Perez-Bayfield, Marcos R.; Broecker, Bruce; Smith, Edwin A.; Scherz, Hal C.; Kirsch, Andrew J.

    2003-01-01

    Children with hydronephrosis are typically investigated by a combination of diuretic renal scintigraphy, ultrasound, and voiding cystourethrography. Unfortunately, there is no gold standard to assess obstruction. The purpose of our study was to evaluate the utility of dynamic contrast enhanced MR urography in the investigation of children with hydronephrosis to define urinary tract anatomy, to calculate differential renal function and to assess urinary tract obstruction. Dynamic contrast-enhanced MR imaging was performed in 40 children with unilateral hydronephrosis. There were 14 girls and 26 boys with an age range of 1 month to 14 years (mean 1.4 years). The information from traditional imaging modalities was compared to the information obtained from the single MR study. The anatomic imaging with MR urography was superior to other modalities. The split renal function was estimated with MR urography by calculating the volume of enhancing renal parenchyma and was comparable to renal scintigraphy (r=0.98). By using surgery versus non-surgery as the decision point, with MR urography the sensitivity was 100%, specificity 71%, positive predictive value 86%, negative predictive value 100%, and diagnostic efficiency 90%. For renal scintigraphy the sensitivity was 96%, the specificity 56%, positive predictive value 76%, negative predictive value 90%, and diagnostic efficiency 79%. Dynamic contrast-enhanced MR urography provides superior anatomic and functional information when compared with ultrasound and diuretic renal scintigraphy. The information is gathered in a single study that does not use ionizing radiation. It is likely that MR urography will replace renal scintigraphy in the evaluation of hydronephrosis in children. (orig.)

  11. MR imaging of kidneys: functional evaluation using F-15 perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grattan-Smith, J. Damien; Jones, Richard A.; Little, Stephen [Department of Pediatric Radiology, Children' s Healthcare of Atlanta, Emory University School of Medicine, 1001 Johnson Ferry Road, GA 30342, Atlanta (United States); Perez-Bayfield, Marcos R.; Broecker, Bruce; Smith, Edwin A.; Scherz, Hal C.; Kirsch, Andrew J. [Department of Pediatric Urology, Children' s Healthcare of Atlanta, Emory University School of Medicine, GA 30342, Atlanta (United States)

    2003-05-01

    Children with hydronephrosis are typically investigated by a combination of diuretic renal scintigraphy, ultrasound, and voiding cystourethrography. Unfortunately, there is no gold standard to assess obstruction. The purpose of our study was to evaluate the utility of dynamic contrast enhanced MR urography in the investigation of children with hydronephrosis to define urinary tract anatomy, to calculate differential renal function and to assess urinary tract obstruction. Dynamic contrast-enhanced MR imaging was performed in 40 children with unilateral hydronephrosis. There were 14 girls and 26 boys with an age range of 1 month to 14 years (mean 1.4 years). The information from traditional imaging modalities was compared to the information obtained from the single MR study. The anatomic imaging with MR urography was superior to other modalities. The split renal function was estimated with MR urography by calculating the volume of enhancing renal parenchyma and was comparable to renal scintigraphy (r=0.98). By using surgery versus non-surgery as the decision point, with MR urography the sensitivity was 100%, specificity 71%, positive predictive value 86%, negative predictive value 100%, and diagnostic efficiency 90%. For renal scintigraphy the sensitivity was 96%, the specificity 56%, positive predictive value 76%, negative predictive value 90%, and diagnostic efficiency 79%. Dynamic contrast-enhanced MR urography provides superior anatomic and functional information when compared with ultrasound and diuretic renal scintigraphy. The information is gathered in a single study that does not use ionizing radiation. It is likely that MR urography will replace renal scintigraphy in the evaluation of hydronephrosis in children. (orig.)

  12. MiR-26b Mimic Inhibits Glioma Proliferation In Vitro and In Vivo Suppressing COX-2 Expression.

    Science.gov (United States)

    Chen, Zheng-Gang; Zheng, Chuan-Yi; Cai, Wang-Qing; Li, Da-Wei; Ye, Fu-Yue; Zhou, Jian; Wu, Ran; Yang, Kun

    2017-08-11

    Glioma is the most common malignant tumor of the nervous system. Studies have shown the microRNA (miR)-26b/cyclooxygenase (COX)-2 axis in the development and progression in many tumor cells. Our study aims to investigate the effect and mechanism of miR-26b/COX-2 axis in glioma. Decreased expression of miR-26b with increased level of COX-2 was found in glioma tissues compared with matched normal tissues. A strong negative correlation was observed between the level of miR-26b and COX-2 in 30 glioma tissues. The miR-26b was then overexpressed by transfecting miR-26b mimic into U-373 cells. The invasive cell number and wounld closing rate were reduced in U-373 cells transfected with miR-26b mimic. Besides, COX2 siRNA enhanced the effect of miR-26b mimic in suppressing the expression of p-ERK1 and p-JNK. Finally, the in vivo experiment revealed that miR-26b mimic transfection strongly reduced the tumor growth, tumor volume and the expression of matrix metalloproteinase (MMP)-2, MMP-9). Taken together, our research indicated a miR-26b/COX-2/ERK/JNK axis in regulating the motility of glioma in vitro and in vivo, providing a new sight for treatment of glioma.

  13. Metabolic changes in the auditory cortex in presbycusis demonstrated by MR spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Profant, Oliver; Balogová, Zuzana; Dezortová, M.; Wagnerová, D.; Hájek, M.; Syka, Josef

    2013-01-01

    Roč. 48, č. 8 (2013), s. 795-800 ISSN 0531-5565 R&D Projects: GA ČR GAP304/10/1872 Grant - others:GA MZd(CZ) 00023001IKEM Institutional support: RVO:68378041 Keywords : Presbycusis * Auditory cortex * MR spectroscopy Subject RIV: FH - Neurology Impact factor: 3.529, year: 2013

  14. Conductivity, water temperature, Coccolith species counts, and others collected from R/V Bellows in Gulf of Mexico from 2011-10-24 to 2011-10-26 (NCEI Accession 0159274)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset reports conductivity, temperature, and depth data from R/V Bellows cruise BE-1205. This cruise took place from October 24-26, 2011 from the Florida...

  15. Pärimuslik ajalugu ja Fr. R. Kreutzwald / Tiiu Jaago

    Index Scriptorium Estoniae

    Jaago, Tiiu, 1960-

    2005-01-01

    Pärimuslik ajalugu kui rahvapärane ajalookäsitus, mida saab uurida folkloorse jutustamise kaudu. Fr. R. Kreutzwaldi ja F. K. H. Kruse sõnavõttudest Aruküla koobaste päritolu kohta ajakirjas "Das Inland" aastast 1844

  16. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    Science.gov (United States)

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude

  17. MR imaging findings and MR criteria for instability in osteochondritis dissecans of the elbow in children

    International Nuclear Information System (INIS)

    Jans, Lennart B.O.; Ditchfield, Michael; Anna, Gomez; Jaremko, Jacob L.; Verstraete, Koenraad L.

    2012-01-01

    Purpose: Osteochondritis dissecans (OCD) of the elbow is an uncommon cause of elbow pain in adolescents and occurs at different locations in the elbow joint. Early diagnosis and treatment may prevent surgery. The aim of the study is to describe the MR imaging features of OCD at initial imaging, and to correlate these findings with surgical findings of stability and instability with arthroscopic findings as the reference standard. Methods: Patients were identified through a keyword search of the radiology information system from 2000 to 2009. Twenty-five patients (26 elbows) with OCD of the elbow were identified (age 10.4–18 years, mean age 14 years). MR studies were retrospectively reviewed by two radiologists in consensus to define MR imaging findings and to determine the presence of previously described MR imaging criteria for OCD instability (i.e., high T2 signal rim, surrounding cysts, high T2 signal fracture line, fluid-filled osteochondral defect). Sensitivity of the individual and combined criteria was calculated. Results: OCD occurred in the capitellum in 24 patients (92%), in the trochlea in 2 patients (8%) and radial head in 1 patient (4%). Loose bodies were identified in 11 (42%) patients. Eighteen patients demonstrated MRI findings in keeping with unstable lesions. In all 11 patients who had surgery the surgical findings of instability correlated with the MRI findings. When combined, the MR criteria were 100% sensitive for instability of OCD lesions of the elbow. Conclusion: The vast majority of OCD of the elbow occurs in the capitellum. When used together, the MR criteria for instability were 100% sensitive for evaluation OCD lesions of the elbow.

  18. Multiparametric MR assessment of pediatric brain tumors

    International Nuclear Information System (INIS)

    Tzika, A.A.; Astrakas, L.G.; Zarifi, M.K.; Petridou, N.; Young-Poussaint, T.; Goumnerova, L.; Black, P.McL.; Zurakowski, D.; Anthony, D.C.

    2003-01-01

    MR assessment of pediatric brain tumors has expanded to include physiologic information related to cellular metabolites, hemodynamic and diffusion parameters. The purpose of this study was to investigate the relationship between MR and proton MR spectroscopic imaging in children with primary brain tumors. Twenty-one patients (mean age 9 years) with histologically verified brain tumors underwent conventional MR imaging, hemodynamic MR imaging (HMRI) and proton MR spectroscopic imaging (MRSI). Fourteen patients also had diffusion-weighted MR imaging (DWMRI). Metabolic indices including choline-containing compounds (Cho), total creatine (tCr) and lipids/lactate (L) were derived by proton MRSI, relative cerebral blood volume (rCBV) by HMRI, and apparent tissue water diffusion coefficients (ADC) by DWMRI. Variables were examined by linear regression and correlation as well as by ANOVA. Cho (suggestive of tumor cellularity and proliferative activity) correlated positively with rCBV, while the relationship between Cho and ADC (suggestive of cellular density) was inverse (P<0.001). The relationship between rCBV and ADC was also inverse (P=0.004). Cho and lipids (suggestive of necrosis and/or apoptosis) were not significantly correlated (P=0.51). A positive relationship was found between lipids and ADC (P=0.002). The relationships between Cho, rCBV, ADC and lipids signify that tumor physiology is influenced by the tumor's physical and chemical environment. Normalized Cho and lipids distinguished high-grade from low-grade tumors (P<0.05). Multiparametric MR imaging using MRSI, HMRI and DWMRI enhances assessment of brain tumors in children and improves our understanding of tumor physiology while promising to distinguish higher- from lower-malignancy tumors, a distinction that is particularly clinically important among inoperable tumors. (orig.)

  19. Dynamical analysis of cylindrically symmetric anisotropic sources in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, M.; Azmat, Hina [COMSATS Institute of Information Technology, Department of Mathematics, Lahore (Pakistan); Noureen, Ifra [University of Management and Technology, Department of Mathematics, Lahore (Pakistan)

    2017-03-15

    In this paper, we have analyzed the stability of cylindrically symmetric collapsing object filled with locally anisotropic fluid in f(R, T) theory, where R is the scalar curvature and T is the trace of stress-energy tensor of matter. Modified field equations and dynamical equations are constructed in f(R, T) gravity. The evolution or collapse equation is derived from dynamical equations by performing a linear perturbation on them. The instability range is explored in both the Newtonian and the post-Newtonian regimes with the help of an adiabatic index, which defines the impact of the physical parameters on the instability range. Some conditions are imposed on the physical quantities to secure the stability of the gravitating sources. (orig.)

  20. Differentiation of hemangioblastomas from pilocytic astrocytomas using 3-T magnetic resonance perfusion-weighted imaging and MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    She, D.J.; Xing, Z.; Zeng, Z.; Cao, D.R. [First Affiliated Hospital of Fujian Medical University, Department of Radiology, Fuzhou, Fujian (China); Shang, X.Y. [University of California, San Diego, Department of Medicine and the Moores UCSD Cancer Center, La Jolla, CA (United States)

    2015-03-01

    Hemangioblastomas and pilocytic astrocytomas (PAs) present similar imaging features on conventional MR imaging, making differential diagnosis a challenge. The purpose of this study was to evaluate the usefulness of dynamic susceptibility-weighted contrast-enhanced perfusion-weighted imaging (DSC-PWI) and proton MR spectroscopic imaging in the differentiation of hemangioblastomas and PAs. A 3.0-T MR imaging unit was used to perform DSC-PWI and conventional MR imaging on 14 patients with hemangioblastomas and 22 patients with PAs. Four patients with hemangioblastomas and 10 PA patients also underwent proton MR spectroscopy. Parameters of relative peak height (rPH) and relative percentage of signal intensity recovery (rPSR) were acquired by DSC-PWI and variables of N-acetylaspasrtate (NAA)/creatine (Cr), choline (Cho)/Cr, and lactate-lipid (Lac-Lip)/Cr by MR spectroscopy. The sensitivity, specificity, and the area under the receiver operating characteristic curve of all analyzed parameters at respective cutoff values were determined. Higher rPH but lower rPSR values were detected in hemangioblastomas compared to PAs. The NAA/Cr ratio was significantly lower in hemangioblastomas compared with PAs. The threshold values ≥3.2 for rPH provide sensitivity, specificity, positive predictive values, and negative predictive values of 85.7, 95.5, 92.3, and 91.3 %, respectively, for differentiating hemangioblastomas from PAs. The optimal threshold values were ≤0.9 for rPSR and ≤1.5 for NAA/Cr ratios in tumor. Significantly higher rPH and lower NAA/Cr were seen in patients with hemangioblastomas when compared with PA patients, suggesting that DSC-PWI and proton MR spectroscopy are helpful in the characterization and differentiation of these two types of tumors. (orig.)

  1. The muscle-specific protein phosphatase PP1G/R(GL)(G(M))is essential for activation of glycogen synthase by exercise

    DEFF Research Database (Denmark)

    Aschenbach, W G; Suzuki, Y; Breeden, K

    2001-01-01

    In skeletal muscle both insulin and contractile activity are physiological stimuli for glycogen synthesis, which is thought to result in part from the dephosphorylation and activation of glycogen synthase (GS). PP1G/R(GL)(G(M)) is a glycogen/sarcoplasmic reticulum-associated type 1 phosphatase...... that was originally postulated to mediate insulin control of glycogen metabolism. However, we recently showed (Suzuki, Y., Lanner, C., Kim, J.-H., Vilardo, P. G., Zhang, H., Jie Yang, J., Cooper, L. D., Steele, M., Kennedy, A., Bock, C., Scrimgeour, A., Lawrence, J. C. Jr., L., and DePaoli-Roach, A. A. (2001) Mol....... Cell. Biol. 21, 2683-2694) that insulin activates GS in muscle of R(GL)(G(M)) knockout (KO) mice similarly to the wild type (WT). To determine whether PP1G is involved in glycogen metabolism during muscle contractions, R(GL) KO and overexpressors (OE) were subjected to two models of contraction...

  2. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  3. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  4. Från outsiderfilmmakare till etablerad indieregissör : David Lynch, Jim Jarmusch och Steven Soderbergh

    OpenAIRE

    Simberg, Maximilian

    2014-01-01

    Det här arbetet behandlar kreativ frihet och konstnärligt oberoende i filmskapande, utgående från begreppet independent film och regissörerna David Lynch, Jim Jarmusch och Steven Soderbergh. Den centrala frågeställningen är hur det har varit möjligt för en filmkonstnär att uppnå konstnärligt oberoende och samtidigt ha en långlivad och framgångsrik karriär. Arbetets fokus ligger på de tre regissörernas genombrottsfilmer; Eraserhead, Stranger Than Paradise och sex, lies, and videotape, och förs...

  5. New proposal for non-linear ghost-free massive F(R) gravity: Cosmic acceleration and Hamiltonian analysis

    International Nuclear Information System (INIS)

    Klusoň, Josef; Nojiri, Shin'ichi; Odintsov, Sergei D.

    2013-01-01

    We propose new version of massive F(R) gravity which is natural generalization of convenient massive ghost-free gravity. Its Hamiltonian formulation in scalar-tensor frame is developed. We show that such F(R) theory is ghost-free. The cosmological evolution of such theory is investigated. Despite the strong Bianchi identity constraint the possibility of cosmic acceleration (especially, in the presence of cold dark matter) is established. Ghost-free massive F(R,T) gravity is also proposed

  6. Intracranial CSF flow on cine-MR. 2. Qualitative analysis in CSF dynamics by MR signal ratio of CSF to fat tissue in healthy subjects and patients with aqueduct stenosis

    International Nuclear Information System (INIS)

    Kadowaki, Chikafusa; Hara, Mitsuhiro; Takeuchi, Kazuo; Saito, Isamu

    1994-01-01

    Changes in MR signal intensities (SIs) of CSF and relative MR signal ratios (SRs) of intraventricular CSF to fat tissue were evaluated in 5 healthy adults on cine MR images during a cardiac cycle in a study of normal intracranial CSF dynamics. The altered patterns of MR SIs and SRs in 6 patients with aqueduct stenosis were compared with normal CSF flow patterns in a demonstration of CSF dynamics changes. MR SIs of CSF within the ventricles were measured on each cine image obtained by cardiac gated, multiframe, cine MR imaging. Chronological changes in MR SIs and SRs during a cardiac cycle were compared with the actual CSF flow visualized on real cine images. In normal CSF circulation, MR SIs of CSF within the ventricles were reduced quickly following an R-wave on ECG to 15% of the R-R interval, after which SIs fluctuated slightly. These changes in MR SIs of CSF could only be related to the pulsatile CSF flow through the foramen of Monro into the anterior part of the third ventricle during early cardiac systole. MR SRs of CSF to fat tissue fluctuated according to the actual CSF flow within the ventricles during a cardiac cycle. MR SRs in the third ventricle decreased to 20-30% of the R-R interval following the R-wave due to downward CSF flow during early cardiac systole, and decreased again from late cardiac systole to diastole due to caudal CSF flow in the third ventricle. In the fourth ventricle, MR SRs of CSF decreased to 60-80% of the R-R interval because of the CSF flow through the aqueduct during cardiac diastole. In patients with aqueduct stenosis, MR SRs of CSF within the ventricles fluctuated randomly, and the amplitude of MR SRs was also greater than in subjects with a patent aqueduct. These changes were identified as turbulence and stagnation due to obstruction in the CSF pathway. Analysis of chronological changes in MR signal ratios of CSF to fat is useful in demonstrating the pathophysiologic features of intracranial CSF dynamics. (author) 52 refs

  7. MR findings of central nerocytoma

    International Nuclear Information System (INIS)

    Lee, Chang Hoon; Kim, Dong Ik; Lee, Byung Hee; Kim, Myung Soon

    1997-01-01

    Central neurocytoma is a reae neuronal differentiated intraventricular tomor of young adults. The purpose of this study was to evaluate the characteristic MR appearance of central neurocytoma. We retrospectively reviewed MR images of 12 patients with central neurocytoma, confirmed by ultrastructural and immunohistochemical study. We analyzed patient age, and on all sequences, tumor location, extension into the third ventricle, involvement of brain parenchyma, cyst, hemorrhage, vascular signal void and signal intensity ; and egree of Gd-enhancement was examined on MR images, pattern of calcification on CT, and neovascularity, tumor staining on angiography. Age distribution was wide ranging from 26 to 64 years ; the most frequent age group was the fourth decade (five patients). All tumors except one (in the third ventricle) were located in the lateral ventricle and most were seen in the region of the foramen of Monro (10 cases). Tumors showed extension into the third ventricle and involvement of parenchyma in three cases. The internal architecture of the tumor was heterogenous and consisted of cysts (83%), hemorrhage (25%) and vascular signal void (25%). The solid portion of the tumor showed variable signal intensity on T1-weighted images and iso or high signal intensity on T2- and proton density-weighted images. On MR imaging, mild to moderate heterogenous Gd-enhancement was seen in ten cases (83%), and on CT, a spotted, amorphous, nodular pattern of calcifications was seen in seven cases (63%). On angiography, neovasevlarity and tumor staining was seen in three cases (100%). The typical location of the lateral and third ventricles and MR imaging characteristics including variable signal intensity and heterogenous internal architecture are helpful in the diagnosis of central neurocytoma in young adults

  8. Solar System constraints on a cosmologically viable f(R) theory

    Energy Technology Data Exchange (ETDEWEB)

    Bisabr, Yousef, E-mail: y-bisabr@srttu.ed [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, Tehran 16788 (Iran, Islamic Republic of)

    2010-01-18

    Recently, a model f(R) theory is proposed (Miranda et al. (2009)) which is cosmologically viable and distinguishable from LAMBDACDM. We use chameleon mechanism to investigate viability of the model in terms of Solar System experiments.

  9. Fetal kidney programming by severe food restriction: effects on structure, hormonal receptor expression and urinary sodium excretion in rats.

    Science.gov (United States)

    Vaccari, Barbara; Mesquita, Flavia F; Gontijo, Jose A R; Boer, Patricia A

    2015-03-01

    The present study investigates, in 23-day-old and adult male rats, the effect of severe food restriction in utero on blood pressure (BP), and its association with nephron structure and function changes, angiotensin II (AT1R/AT2R), glucocorticoid (GR) and mineralocorticoid (MR) receptor expression. The daily food supply to pregnant rats was measured and one group (n=15) received normal quantity of food (NF) while the other received 50% of that (FR50%) (n=15). Kidneys were processed to AT1R, AT2R, MR, and GR immunolocalization and for western blotting analysis. The renal function was estimated by creatinine and lithium clearances in 12-week-old offspring. By stereological analyses, FR50% offspring present a reduction of nephron numbers (35%) with unchanged renal volume. Expression of AT1R and AT2R was significantly decreased in FR50% while the expression of GR and MR increased in FR50%. We also verified a pronounced decrease in urinary sodium excretion accompanied by increased BP in 12-week-old FR50% offspring. The current data suggest that changes in renal function are conducive to excess sodium tubule reabsorption, and this might potentiate the programming of adult hypertension. It is plausible to arise in the current study an association between decreasing natriuresis, reciprocal changes in renal AngII and steroid receptors with the hypertension development found in FR50% compared with age-matched NF offspring. © The Author(s) 2013.

  10. Envelope composition of Salmonella typhimurium 395 MS and 395 MR10 assesses by X-ray photoelectron spectroscopy (ESCA)

    International Nuclear Information System (INIS)

    Magnusson, K.F.; Johansson, L.

    1977-01-01

    The Salmonella typhimurium 395 MS and MR10 bacteria and lipopolysaccharide (LPS) were studied by X-ray photoelectron spectroscopy with the aid of the ESCA technique for the in situ analysis of chemical elements (C, O and N) at the surface. The nitrogen peak was large in both bacteria implying the presence of protein in the very outer part of the bacterial envelope due to the surface-sensitive measurement. The nitrogen peak was larger in the MR10 than in the MS bacteria, presumably reflecting an increased exposure of proteins concomitantly with the reduction of the LPS in MR10. After corrections for background and sensitivity of detection the relative intensities of the peaks agreed appreciably well with the proposed chemical structure of the LPS, indicating that at least semiquantitative relationships between the elements were obtained. (author)

  11. Study of Antigravity in an F(R) Model and in Brans-Dicke Theory with Cosmological Constant

    OpenAIRE

    Oikonomou, V. K.; Karagiannakis, N.

    2014-01-01

    We study antigravity, that is having an effective gravitational constant with a negative sign, in scalar-tensor theories originating from $F(R)$-theory and in a Brans-Dicke model with cosmological constant. For the $F(R)$ theory case, we obtain the antigravity scalar-tensor theory in the Jordan frame by using a variant of the Lagrange multipliers method and we numerically study the time dependent effective gravitational constant. As we shall demonstrate by using a specific $F(R)$ model, altho...

  12. Solar System constraints on a cosmologically viable f(R) theory

    International Nuclear Information System (INIS)

    Bisabr, Yousef

    2010-01-01

    Recently, a model f(R) theory is proposed (Miranda et al. (2009)) which is cosmologically viable and distinguishable from ΛCDM. We use chameleon mechanism to investigate viability of the model in terms of Solar System experiments.

  13. Chromosome r(10(p15.3q26.12 in a newborn child: case report

    Directory of Open Access Journals (Sweden)

    Jonasson Jon

    2009-12-01

    Full Text Available Abstract Background Ring chromosome 10 is a rare cytogenetic finding. Of the less than 10 reported cases we have found in the literature, none was characterized using high-resolution microarray analysis. Ring chromosomes are frequently unstable due to sister chromatid exchanges and mitotic failures. When mosaicism is present, the interpretation of genotype-phenotype correlations becomes extremely difficult. Results We report on a newborn girl with growth retardation, microcephaly, congenital heart defects, dysmorphic features and psychomotor retardation. Karyotyping revealed a non-mosaic apparently stable ring chromosome 10 replacing one of the normal homologues in all analyzed metaphases. High-resolution oligonucleotide microarray analysis showed a de novo approximately 12.5 Mb terminal deletion 10q26.12 -> qter and a corresponding 285 kb terminal deletion of 10pter -> p15.3. Conclusion This case demonstrates that an increased nuchal translucency thickness detected by early ultrasonography should preferably lead to not only QF-PCR for the diagnosis of Down syndrome but also karyotyping. In the future, microarray analysis, which needs further evaluation, might become the method of choice. The clinical phenotype of our patient was in agreement with that of patients with a terminal 10q deletion. For the purpose of genotype-phenotype analysis, there seems to be no need for a "ring syndrome" concept.

  14. 10 CFR 26.125 - Licensee testing facility personnel.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Licensee testing facility personnel. 26.125 Section 26.125 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.125... reports, if any; results of tests that establish employee competency for the position he or she holds...

  15. Trastuzumab produces therapeutic actions by upregulating miR-26a and miR-30b in breast cancer cells.

    Directory of Open Access Journals (Sweden)

    Takehiro Ichikawa

    Full Text Available OBJECTIVE: Trastuzumab has been used for the treatment of HER2-positive breast cancer (BC. However, a subset of BC patients exhibited resistance to trastuzumab therapy. Thus, clarifying the molecular mechanism of trastuzumab treatment will be beneficial to improve the treatment of HER2-positive BC patients. In this study, we identified trastuzumab-responsive microRNAs that are involved in the therapeutic effects of trastuzumab. METHODS AND RESULTS: RNA samples were obtained from HER2-positive (SKBR3 and BT474 and HER2-negetive (MCF7 and MDA-MB-231 cells with and without trastuzumab treatment for 6 days. Next, we conducted a microRNA profiling analysis using these samples to screen those microRNAs that were up- or down-regulated only in HER2-positive cells. This analysis identified miR-26a and miR-30b as trastuzumab-inducible microRNAs. Transfecting miR-26a and miR-30b induced cell growth suppression in the BC cells by 40% and 32%, respectively. A cell cycle analysis showed that these microRNAs induced G1 arrest in HER2-positive BC cells as trastuzumab did. An Annexin-V assay revealed that miR-26a but not miR-30b induced apoptosis in HER2-positive BC cells. Using the prediction algorithms for microRNA targets, we identified cyclin E2 (CCNE2 as a target gene of miR-30b. A luciferase-based reporter assay demonstrated that miR-30b post-transcriptionally reduced 27% (p = 0.005 of the gene expression by interacting with two binding sites in the 3'-UTR of CCNE2. CONCLUSION: In BC cells, trastuzumab modulated the expression of a subset of microRNAs, including miR-26a and miR-30b. The upregulation of miR-30b by trastuzumab may play a biological role in trastuzumab-induced cell growth inhibition by targeting CCNE2.

  16. Influence of f(R) models on the existence of anisotropic self-gravitating systems

    Energy Technology Data Exchange (ETDEWEB)

    Yousaf, Z.; Sharif, M.; Bhatti, M.Z. [University of the Punjab, Department of Mathematics, Lahore (Pakistan); Ilyas, M. [University of the Punjab, Centre for High Energy Physics, Lahore (Pakistan)

    2017-10-15

    This paper aims to explore some realistic configurations of anisotropic spherical structures in the background of metric f(R) gravity, where R is the Ricci scalar. The solutions obtained by Krori and Barua are used to examine the nature of particular compact stars with three different modified gravity models. The behavior of material variables is analyzed through plots and the physical viability of compact stars is investigated through energy conditions. We also discuss the behavior of different forces, equation of state parameter, measure of anisotropy and Tolman-Oppenheimer-Volkoff equation in the modeling of stellar structures. The comparison from our graphical representations may provide evidence for the realistic and viable f(R) gravity models at both theoretical and the astrophysical scale. (orig.)

  17. The interaction between AMPKβ2 and the PP1-targeting subunit R6 is dynamically regulated by intracellular glycogen content.

    Science.gov (United States)

    Oligschlaeger, Yvonne; Miglianico, Marie; Dahlmans, Vivian; Rubio-Villena, Carla; Chanda, Dipanjan; Garcia-Gimeno, Maria Adelaida; Coumans, Will A; Liu, Yilin; Voncken, J Willem; Luiken, Joost J F P; Glatz, Jan F C; Sanz, Pascual; Neumann, Dietbert

    2016-04-01

    AMP-activated protein kinase (AMPK) is a metabolic stress-sensing kinase. We previously showed that glucose deprivation induces autophosphorylation of AMPKβ at Thr-148, which prevents the binding of AMPK to glycogen. Furthermore, in MIN6 cells, AMPKβ1 binds to R6 (PPP1R3D), a glycogen-targeting subunit of protein phosphatase type 1 (PP1), thereby regulating the glucose-induced inactivation of AMPK. In the present study, we further investigated the interaction of R6 with AMPKβ and the possible dependency on Thr-148 phosphorylation status. Yeast two-hybrid (Y2H) analyses and co-immunoprecipitation (IP) of the overexpressed proteins in human embryonic kidney (HEK) 293T) cells revealed that both AMPKβ1 and AMPK-β2 wild-type (WT) isoforms bind to R6. The AMPKβ-R6 interaction was stronger with the muscle-specific AMPKβ2-WT and required association with the substrate-binding motif of R6. When HEK293T cells or C2C12 myotubes were cultured in high-glucose medium, AMPKβ2-WT and R6 weakly interacted. In contrast, glycogen depletion significantly enhanced this protein interaction. Mutation of AMPKβ2 Thr-148 prevented the interaction with R6 irrespective of the intracellular glycogen content. Treatment with the AMPK activator oligomycin enhanced the AMPKβ2-R6 interaction in conjunction with increased Thr-148 phosphorylation in cells grown in low-glucose medium. These data are in accordance with R6 binding directly to AMPKβ2 when both proteins detach from the diminishing glycogen particle, which is simultaneous with increased AMPKβ2 Thr-148 autophosphorylation. Such a model points to a possible control of AMPK by PP1-R6 upon glycogen depletion in muscle. © 2016 Authors; published by Portland Press Limited.

  18. Constraining models of f(R) gravity with Planck and WiggleZ power spectrum data

    International Nuclear Information System (INIS)

    Dossett, Jason; Parkinson, David; Hu, Bin

    2014-01-01

    In order to explain cosmic acceleration without invoking ''dark'' physics, we consider f(R) modified gravity models, which replace the standard Einstein-Hilbert action in General Relativity with a higher derivative theory. We use data from the WiggleZ Dark Energy survey to probe the formation of structure on large scales which can place tight constraints on these models. We combine the large-scale structure data with measurements of the cosmic microwave background from the Planck surveyor. After parameterizing the modification of the action using the Compton wavelength parameter B 0 , we constrain this parameter using ISiTGR, assuming an initial non-informative log prior probability distribution of this cross-over scale. We find that the addition of the WiggleZ power spectrum provides the tightest constraints to date on B 0 by an order of magnitude, giving log 10 (B 0 ) < −4.07 at 95% confidence limit. Finally, we test whether the effect of adding the lensing amplitude A Lens and the sum of the neutrino mass ∑m ν is able to reconcile current tensions present in these parameters, but find f(R) gravity an inadequate explanation

  19. Human fascioliasis: MR imaging findings of hepatic lesions

    International Nuclear Information System (INIS)

    Cevikol, Can; Karaali, Kamil; Senol, Utku; Kabaalioglu, Adnan; Apaydin, Ali; Lueleci, Ersin; Saba, Rabin

    2003-01-01

    Our objective was to describe MR imaging findings of liver lesions in human fascioliasis. The MR imaging of the liver was performed in 29 patients with fascioliasis. Seventeen patients were women and 12 were men, with a mean age of 47.5 years (age range 17-75 years). Hepatic lesions were grouped into five types based on their signal characteristics. Three patients had normal imaging findings. One or more lesions were observed in the other 26 patients. The lesion types and the frequency of appearances were as follows: hyperintensity of the liver capsule on T2-weighted images (n=16, 55.2%); ill-defined slightly hyperintense areas on T2-weighted images (n=18, 62.1%); lesions which were hypointense on T1-weighted and hyperintense on T2-weighted images (n=10, 34.5%); hypointense on T1-weighted images and centrally hypo- or hyperintense, surrounded by peripherally less hyperintense area on T2-weighted images (n=4, 13.8%); and hypointense foci or ill-defined hypointense areas on T1- and T2-weighted images (n=10, 34.5%). We describe the MR imaging features of the disease. Our findings may help the differential diagnosis in which fascioliasis should be added to the list. (orig.)

  20. MicroRNA 26a (miR-26a/KLF4 and CREB-C/EBPβ regulate innate immune signaling, the polarization of macrophages and the trafficking of Mycobacterium tuberculosis to lysosomes during infection.

    Directory of Open Access Journals (Sweden)

    Sanjaya Kumar Sahu

    2017-05-01

    Full Text Available For efficient clearance of Mycobacterium tuberculosis (Mtb, macrophages tilt towards M1 polarization leading to the activation of transcription factors associated with the production of antibacterial effector molecules such as nitric oxide (NO and proinflammatory cytokines such as interleukin 1 β (IL-1β and tumor necrosis factor α (TNF-α. At the same time, resolution of inflammation is associated with M2 polarization with increased production of arginase and cytokines such as IL-10. The transcriptional and post-transcriptional mechanisms that govern the balance between M1 and M2 polarization, and bacteria-containing processes such as autophagy and trafficking of Mtb to lysosomes, are incompletely understood. Here we report for the first time, that the transcription factor KLF4 is targeted by microRNA-26a (miR-26a. During Mtb infection, downregulation of miR-26a (observed both ex vivo and in vivo facilitates upregulation of KLF4 which in turn favors increased arginase and decreased iNOS activity. We further demonstrate that KLF4 prevents trafficking of Mtb to lysosomes. The CREB-C/EBPβ signaling axis also favors M2 polarization. Downregulation of miR-26a and upregulation of C/ebpbeta were observed both in infected macrophages as well as in infected mice. Knockdown of C/ebpbeta repressed the expression of selected M2 markers such as Il10 and Irf4 in infected macrophages. The importance of these pathways is substantiated by observations that expression of miR-26a mimic or knockdown of Klf4 or Creb or C/ebpbeta, attenuated the survival of Mtb in macrophages. Taken together, our results attribute crucial roles for the miR-26a/KLF4 and CREB-C/EBPβsignaling pathways in regulating the survival of Mtb in macrophages. These studies expand our understanding of how Mtb hijacks host signaling pathways to survive in macrophages, and open up new exploratory avenues for host-targeted interventions.

  1. MicroRNA 26a (miR-26a)/KLF4 and CREB-C/EBPβ regulate innate immune signaling, the polarization of macrophages and the trafficking of Mycobacterium tuberculosis to lysosomes during infection.

    Science.gov (United States)

    Sahu, Sanjaya Kumar; Kumar, Manish; Chakraborty, Sohini; Banerjee, Srijon Kaushik; Kumar, Ranjeet; Gupta, Pushpa; Jana, Kuladip; Gupta, Umesh D; Ghosh, Zhumur; Kundu, Manikuntala; Basu, Joyoti

    2017-05-01

    For efficient clearance of Mycobacterium tuberculosis (Mtb), macrophages tilt towards M1 polarization leading to the activation of transcription factors associated with the production of antibacterial effector molecules such as nitric oxide (NO) and proinflammatory cytokines such as interleukin 1 β (IL-1β) and tumor necrosis factor α (TNF-α). At the same time, resolution of inflammation is associated with M2 polarization with increased production of arginase and cytokines such as IL-10. The transcriptional and post-transcriptional mechanisms that govern the balance between M1 and M2 polarization, and bacteria-containing processes such as autophagy and trafficking of Mtb to lysosomes, are incompletely understood. Here we report for the first time, that the transcription factor KLF4 is targeted by microRNA-26a (miR-26a). During Mtb infection, downregulation of miR-26a (observed both ex vivo and in vivo) facilitates upregulation of KLF4 which in turn favors increased arginase and decreased iNOS activity. We further demonstrate that KLF4 prevents trafficking of Mtb to lysosomes. The CREB-C/EBPβ signaling axis also favors M2 polarization. Downregulation of miR-26a and upregulation of C/ebpbeta were observed both in infected macrophages as well as in infected mice. Knockdown of C/ebpbeta repressed the expression of selected M2 markers such as Il10 and Irf4 in infected macrophages. The importance of these pathways is substantiated by observations that expression of miR-26a mimic or knockdown of Klf4 or Creb or C/ebpbeta, attenuated the survival of Mtb in macrophages. Taken together, our results attribute crucial roles for the miR-26a/KLF4 and CREB-C/EBPβsignaling pathways in regulating the survival of Mtb in macrophages. These studies expand our understanding of how Mtb hijacks host signaling pathways to survive in macrophages, and open up new exploratory avenues for host-targeted interventions.

  2. 75 FR 14454 - National Protection and Programs Directorate; National Infrastructure Advisory Council

    Science.gov (United States)

    2010-03-25

    ..., National Infrastructure Advisory Council. [FR Doc. 2010-6633 Filed 3-24-10; 8:45 am] BILLING CODE 9110-9P-P ... Directorate; National Infrastructure Advisory Council AGENCY: National Protection and Programs Directorate... Infrastructure Advisory Council (NIAC) will meet on Tuesday, April 13, 2010, at the National Press Club's...

  3. Decreased Expression of miR-21, miR-26a, miR-29a, and miR-142-3p in CD4+ T Cells and Peripheral Blood from Tuberculosis Patients

    Science.gov (United States)

    Schattling, Stefanie; Kohns, Malte; Sander-Jülch, Claudia; Walzl, Gerhard; Hesseling, Anneke; Mayatepek, Ertan; Fleischer, Bernhard; Marx, Florian M.; Jacobsen, Marc

    2013-01-01

    The vast majority of Mycobacterium tuberculosis (M. tuberculosis) infected individuals are protected from developing tuberculosis and T cells are centrally involved in this process. MicroRNAs (miRNA) regulate T-cell functions and are biomarker candidates of disease susceptibility and treatment efficacy in M. tuberculosis infection. We determined the expression profile of 29 selected miRNAs in CD4+ T cells from tuberculosis patients and contacts with latent M. tuberculosis infection (LTBI). These analyses showed lower expression of miR-21, miR-26a, miR-29a, and miR-142-3p in CD4+ T cells from tuberculosis patients. Whole blood miRNA candidate analyses verified decreased expression of miR-26a, miR-29a, and miR-142-3p in children with tuberculosis as compared to healthy children with LTBI. Despite marked variances between individual donor samples, trends of increased miRNA candidate expression during treatment and recovery were observed. Functional in vitro analysis identified increased miR-21 and decreased miR-26a expression after re-stimulation of T cells. In vitro polarized Interleukin-17 positive T-cell clones showed activation-dependent miR-29a up-regulation. In order to characterize the role of miR-29a (a described suppressor of Interferon-γ in tuberculosis), we analyzed M. tuberculosis specific Interferon-γ expressing T cells in children with tuberculosis and healthy contacts but detected no correlation between miR-29a and Interferon-γ expression. Suppression of miR-29a in primary human T cells by antagomirs indicated no effect on Interferon-γ expression after in vitro activation. Finally, classification of miRNA targets revealed only a moderate overlap between the candidates. This may reflect differential roles of miR-21, miR-26a, miR-29a, and miR-142-3p in T-cell immunity against M. tuberculosis infection and disease. PMID:23613882

  4. Quantitative comparison of PET performance—Siemens Biograph mCT and mMR

    Energy Technology Data Exchange (ETDEWEB)

    Karlberg, Anna M.; Sæther, Oddbjørn [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Eikenes, Live [Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Postbox 8905, 7491 Trondheim (Norway); Goa, Pål Erik [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Department of Physics, Norwegian University of Science and Technology, Trondheim (Norway)

    2016-02-25

    Integrated clinical whole-body PET/MR systems were introduced in 2010. In order to bring this technology into clinical usage, it is of great importance to compare the performance with the well-established PET/CT. The aim of this study was to evaluate PET performance, with focus on image quality, on Siemens Biograph mMR (PET/MR) and Siemens Biograph mCT (PET/CT). A direct quantitative comparison of the performance characteristics between the mMR and mCT system was performed according to National Electrical Manufacturers Association (NEMA) NU 2-2007 protocol. Spatial resolution, sensitivity, count rate and image quality were evaluated. The evaluation was supplemented with additional standardized uptake value (SUV) measurements. The spatial resolution was similar for the two systems. Average sensitivity was higher for the mMR (13.3 kcps/MBq) compared to the mCT system (10.0 kcps/MBq). Peak noise equivalent count rate (NECR) was slightly higher for the mMR (196 kcps @ 24.4 kBq/mL) compared to the mCT (186 kcps @ 30.1 kBq/mL). Scatter fractions in the clinical activity concentration range yielded lower values for the mCT (34.9 %) compared to those for the mMR (37.0 %). Best image quality of the systems resulted in approximately the same mean hot sphere contrast and a difference of 19 percentage points (pp) in mean cold contrast, in favour of the mCT. In general, point spread function (PSF) increased hot contrast and time of flight (TOF) increased both hot and cold contrast. Highest hot contrast for the smallest sphere (10 mm) was achieved with the combination of TOF and PSF on the mCT. Lung residual error was higher for the mMR (22 %) than that for the mCT (17 %), with no effect of PSF. With TOF, lung residual error was reduced to 8 % (mCT). SUV was accurate for both systems, but PSF caused overestimations for the 13-, 17- and 22-mm spheres. Both systems proved good performance characteristics, and the PET image quality of the mMR was close to that of the m

  5. Unified cosmic history in modified gravity: From F(R) theory to Lorentz non-invariant models

    Science.gov (United States)

    Nojiri, Shin'Ichi; Odintsov, Sergei D.

    2011-08-01

    The classical generalization of general relativity is considered as the gravitational alternative for a unified description of the early-time inflation with late-time cosmic acceleration. The structure and cosmological properties of a number of modified theories, including traditional F(R) and Hořava-Lifshitz F(R) gravity, scalar-tensor theory, string-inspired and Gauss-Bonnet theory, non-local gravity, non-minimally coupled models, and power-counting renormalizable covariant gravity are discussed. Different representations of and relations between such theories are investigated. It is shown that some versions of the above theories may be consistent with local tests and may provide a qualitatively reasonable unified description of inflation with the dark energy epoch. The cosmological reconstruction of different modified gravities is provided in great detail. It is demonstrated that eventually any given universe evolution may be reconstructed for the theories under consideration, and the explicit reconstruction is applied to an accelerating spatially flat Friedmann-Robertson-Walker (FRW) universe. Special attention is paid to Lagrange multiplier constrained and conventional F(R) gravities, for latter F(R) theory, the effective ΛCDM era and phantom divide crossing acceleration are obtained. The occurrences of the Big Rip and other finite-time future singularities in modified gravity are reviewed along with their solutions via the addition of higher-derivative gravitational invariants.

  6. Long non-coding RNA TUG1 acts as a miR-26a sponge in human glioma cells.

    Science.gov (United States)

    Li, Jun; An, Gang; Zhang, Meng; Ma, Qingfang

    2016-09-02

    Long non-coding RNA taurine upregulated gene 1 (TUG1) acts as an important regulator in cancer pathogenesis; however, its functional mechanism in glioma development remains unclear. This study aims to explore the potential function of TUG1 in glioma by sponging miR-26a. The expression of TUG1, miR-26a, and phosphatase and tensin homolog (PTEN) in 20 paired glioma tissues was detected by quantitative real-time PCR and subjected to correlation analysis. Bioinformatics analysis was performed by using DIANA Tools. Abnormal TUG1 expression was conducted in two glioma cells to analyze its regulation on miR-26a and PTEN using real-time PCR, western blot, and luciferase reporter assay. TUG1 expression was confirmed to be upregulated in glioma tissues, and showed an inverse correlation with downregulated miR-26a. TUG1 could negatively regulate the expression of miR-26a in glioma cells. The bioinformatics prediction revealed putative miR-26a binding sites within TUG1 transcripts. Further experiments demonstrated the positive regulation of TUG1 on the miR-26a target, PTEN, wherein TUG1 could inhibit the negative regulation of miR-26a on PTEN by binding its 3'UTR. Additionally, the expression of PTEN was also upregulated in glioma tissues, showing a positive or negative correlation with TUG1 or miR-26a, respectively. TUG1 could serve as a miR-26a sponge in human glioma cells, contributing to the upregulation of PTEN. This study revealed a new TUG1/miR-26a/PTEN regulatory mechanism and provided a further understanding of the tumor-suppressive role of TUG1 in glioma development. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Gravitational radiation in quadratic f(R) gravity

    International Nuclear Information System (INIS)

    Naef, Joachim; Jetzer, Philippe

    2011-01-01

    We investigate the gravitational radiation emitted by an isolated system for gravity theories with Lagrange density f(R)=R+aR 2 . As a formal result, we obtain leading order corrections to the quadrupole formula in general relativity. We make use of the analogy of f(R) theories with scalar-tensor theories, which in contrast to general relativity feature an additional scalar degree of freedom. Unlike general relativity, where the leading order gravitational radiation is produced by quadrupole moments, the additional degree of freedom predicts gravitational radiation of all multipoles, in particular, monopoles and dipoles, as this is the case for the most alternative gravity theories known today. An application to a hypothetical binary pulsar moving in a circular orbit yields the rough limit a 17 m 2 by constraining the dipole power to account at most for 1% of the quadrupole power as predicted by general relativity.

  8. Congenital cytomegalovirus infection: contribution and best timing of prenatal MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cannie, Mieke M. [University Hospital Brugmann, Universite Libre de Bruxelles, Department of Radiology, Brussels (Belgium); UZ Brussel, Vrije Universiteit Brussel, Department of Radiology, Brussel (Belgium); Devlieger, Roland; Catte, Luc de; Valk, Elise van der [University Hospitals Leuven, Department of Obstetrics and Gynecology, Leuven (Belgium); Leyder, Mina; Foulon, Walter [UZ Brussel, Vrije Universiteit Brussel, Department of Obstetrics, Brussel (Belgium); Claus, Filip [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Onze-Lieve-Vrouw Hospital, Department of Radiology, Aalst (Belgium); Leus, Astrid [UZ Brussel, Vrije Universiteit Brussel, Department of Radiology, Brussel (Belgium); Cossey, Veerle [University Hospitals Leuven, Neonatal Intensive Care Unit, Leuven (Belgium); Foulon, Ina [UZ Brussel, Vrije Universiteit Brussel, Department of Otolaryngology - Head and Neck Surgery, Brussel (Belgium); Cos, Teresa; Jani, Jacques C. [University Hospital Brugmann, Universite Libre de Bruxelles, Department of Obstetrics and Gynecology, Brussels (Belgium); Bernaert, Anja [Sint-Augustinus Hospital, Department of Radiology, Antwerp (Belgium); Oyen, Raymond [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2016-10-15

    To predict sensorineural hearing loss (SNHL) and neurological impairment in congenital cytomegalovirus (cCMV) infection using MR imaging and define the best timing in pregnancy for prenatal assessment. In 121 patients with confirmed cCMV infection, brain features at MR imaging were respectively graded from 1 to 5: normal; isolated frontal/parieto-occipital hyperintensity; temporal periventricular hyperintensity; temporal/occipital cysts and/or intraventricular septa; migration disorders. Grading was correlated with postnatal SNHL and neurological impairment using regression analysis. In 51 fetuses with MR examinations at 26.9 and 33.0 weeks, the predictive value of SNHL and neurological impairment was compared using ROC curves. Postnatal follow-up showed SNHL in 18 infants and neurological impairment in 10. MR grading was predictive of SNHL and of neurological impairment (P < 0.001). In grade 1 or 2, none had SNHL and 1/74 had neurological impairment. The areas under ROC curves for prediction of postnatal SNHL and of neurological impairment from first and second MR examination were comparable. Our data suggest that in cCMV infection, prediction of SNHL and neurological impairment is feasible by fetal MR imaging with a high negative predictive value and can equally be done at 27 or 33 weeks of gestation. (orig.)

  9. Congenital cytomegalovirus infection: contribution and best timing of prenatal MR imaging

    International Nuclear Information System (INIS)

    Cannie, Mieke M.; Devlieger, Roland; Catte, Luc de; Valk, Elise van der; Leyder, Mina; Foulon, Walter; Claus, Filip; Leus, Astrid; Cossey, Veerle; Foulon, Ina; Cos, Teresa; Jani, Jacques C.; Bernaert, Anja; Oyen, Raymond

    2016-01-01

    To predict sensorineural hearing loss (SNHL) and neurological impairment in congenital cytomegalovirus (cCMV) infection using MR imaging and define the best timing in pregnancy for prenatal assessment. In 121 patients with confirmed cCMV infection, brain features at MR imaging were respectively graded from 1 to 5: normal; isolated frontal/parieto-occipital hyperintensity; temporal periventricular hyperintensity; temporal/occipital cysts and/or intraventricular septa; migration disorders. Grading was correlated with postnatal SNHL and neurological impairment using regression analysis. In 51 fetuses with MR examinations at 26.9 and 33.0 weeks, the predictive value of SNHL and neurological impairment was compared using ROC curves. Postnatal follow-up showed SNHL in 18 infants and neurological impairment in 10. MR grading was predictive of SNHL and of neurological impairment (P < 0.001). In grade 1 or 2, none had SNHL and 1/74 had neurological impairment. The areas under ROC curves for prediction of postnatal SNHL and of neurological impairment from first and second MR examination were comparable. Our data suggest that in cCMV infection, prediction of SNHL and neurological impairment is feasible by fetal MR imaging with a high negative predictive value and can equally be done at 27 or 33 weeks of gestation. (orig.)

  10. Solar system and equivalence principle constraints on f(R) gravity by the chameleon approach

    International Nuclear Information System (INIS)

    Capozziello, Salvatore; Tsujikawa, Shinji

    2008-01-01

    We study constraints on f(R) dark energy models from solar system experiments combined with experiments on the violation of the equivalence principle. When the mass of an equivalent scalar field degree of freedom is heavy in a region with high density, a spherically symmetric body has a thin shell so that an effective coupling of the fifth force is suppressed through a chameleon mechanism. We place experimental bounds on the cosmologically viable models recently proposed in the literature that have an asymptotic form f(R)=R-λR c [1-(R c /R) 2n ] in the regime R>>R c . From the solar system constraints on the post-Newtonian parameter γ, we derive the bound n>0.5, whereas the constraints from the violations of the weak and strong equivalence principles give the bound n>0.9. This allows a possibility to find the deviation from the Λ-cold dark matter (ΛCDM) cosmological model. For the model f(R)=R-λR c (R/R c ) p with 0 -10 , which shows that this model is hardly distinguishable from the ΛCDM cosmology

  11. Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Seitun, Sara [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Messalli, Giancarlo; Catalano, Onofrio [SDN Foundation - IRCCS, Naples (Italy); Martini, Chiara; Cademartiri, Filippo [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Nieman, Koen; Rossi, Alexia; Mollet, Nico R. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Guaricci, Andrea I. [Azienda Ospedaliero-Universitaria di Foggia, Department of Cardiology, Foggia (Italy); Tedeschi, Carlo [Ospedale San Gennaro, Department of Cardiology, Naples (Italy)

    2012-05-15

    To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 {+-} 14% for CT vs. 52 {+-} 14% for MR; r = 0.73; p > 0.05); RV EF (47 {+-} 12% for CT vs. 47 {+-} 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 {+-} 21 ml/m{sup 2} for CT vs. 76 {+-} 25 ml/m{sup 2} for MR; r = 0.59; p > 0.05); RV EDV (84 {+-} 25 ml/m{sup 2} for CT vs. 80 {+-} 23 ml/m{sup 2} for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 {+-} 19 ml/m{sup 2} for CT vs. 38 {+-} 23 ml/m{sup 2} for MR; r = 0.76; p > 0.05); RV ESV (46 {+-} 21 ml/m{sup 2} for CT vs. 43 {+-} 18 ml/m{sup 2} for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. circle Cardiac-CT is able to provide Left and Right Ventricular function. circle Cardiac-CT is accurate as MR for LV and RV volume assessment. (orig.)

  12. ONKALO POSE experiment. Determination of in situ thermal properties of rocks in drillholes ONK-PP340, ONK-PP346, ONK-PP398, ONK-PP399, ONK-PP405, ONK-PP411

    International Nuclear Information System (INIS)

    Korpisalo, A.; Suppala, I.; Kukkonen, I.; Koskinen, T.

    2014-12-01

    The thermal drillhole device TERO76 (for diameter 76 mm drillholes) used in this study for determining thermal properties of rocks in situ was developed at the Geological Survey of Finland for Posiva in the early 2000's. The measurement method is based on monitoring the temperature variation of a cylindrical heating source in a drillhole. The measured data can be interpreted with full numerical 3D codes as well as with an analytical infinite line source method, a 'rapid interpretation tool', which makes it possible to calculate the first estimates of thermal properties already in the field. Both methods were applied in this study. Because of the unique measurement geometry, only the thermal conductivities can accurately be estimated using the late times of heating periods (accuracy ± 2%). The cylindrical source method cannot directly give the thermal diffusivity or volumetric heat capacity at a sufficient accuracy. Thermal diffusivities are estimated by using the average specific heat capacities and densities of the rock type at the measurement point, or the laboratory results on the general diffusivity-conductivity relationship for different Olkiluoto rock types. The latter technique was applied in this study. Thermal properties were determined in four shallow drillholes (ONK-PP398, ONK-PP399, ONK-PP405, ONK-PP411) located in the ONKALO investigation niche 3 (ONK-TKU-3620) at the access tunnel chainage of 3620 m. The measurement positions (17) were strictly selected on the grounds that approximately an equal number of in situ results would be available in both veined gneiss (VGN) and pegmatitic granite (PGR). The results from the drillholes ONK-PP340 and ONK-PP346 measured in a previous project are also presented in this report. In veined gneiss, the average conductivity determined with numerical model of the present measurements is 3.49 (2.83) Wm -1 K -1 and diffusivity 1.89 x 10 -6 (1.3 10 -6 ) m 2 s -1 . The laboratory values of Olkiluoto rocks

  13. 26 CFR 1.936-10 - Qualified investments.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Qualified investments. 1.936-10 Section 1.936... (CONTINUED) INCOME TAXES Possessions of the United States § 1.936-10 Qualified investments. (a) In general. [Reserved] (b) Qualified investments in Puerto Rico. [Reserved] (c) Qualified investment in certain...

  14. Nonsuppressing normal thymus on chemical-shift MR imaging and anterior mediastinal lymphoma. Differentiation with diffusion-weighted MR imaging by using the apparent diffusion coefficient

    International Nuclear Information System (INIS)

    Priola, Adriano Massimiliano; Priola, Sandro Massimo; Gned, Dario; Veltri, Andrea; Giraudo, Maria Teresa

    2018-01-01

    To prospectively evaluate usefulness of the apparent diffusion coefficient (ADC) in differentiating anterior mediastinal lymphoma from nonsuppressing normal thymus on chemical-shift MR, and to look at the relationship between patient age and ADC. Seventy-three young subjects (25 men, 48 women; age range, 9-29 years), who underwent chemical-shift MR and diffusion-weighted MR were divided into a normal thymus group (group A, 40 subjects), and a lymphoma group (group B, 33 patients). For group A, all subjects had normal thymus with no suppression on opposed-phase chemical-shift MR. Two readers measured the signal intensity index (SII) and ADC. Differences in SII and ADC between groups were tested using t-test. ADC was correlated with age using Pearson correlation coefficient. Mean SII±standard deviation was 2.7±1.8% for group A and 2.2±2.4% for group B, with no significant difference between groups (P=.270). Mean ADC was 2.48±0.38 x 10 -3 mm 2 /s for group A and 1.24±0.23 x 10 -3 mm 2 /s for group B. A significant difference between groups was found (P<.001), with no overlap in range. Lastly, significant correlation was found between age and ADC (r=0.935, P<.001) in group A. ADC of diffusion-weighted MR is a noninvasive and accurate parameter for differentiating lymphoma from nonsuppressing thymus on chemical-shift MR in young subjects. (orig.)

  15. Verwendung von Polypropylen/Polyglactin 910- (PP910- und Polypropylen/Polyglecapron 25 (PP25- Netzen bei Beckenbodenprolaps - eine retrospektive Analyse

    Directory of Open Access Journals (Sweden)

    Schwegler Ch

    2009-01-01

    Full Text Available Die Entwicklung von Polypropylen- Implantaten zur Behandlung von Bauchwandhernien stellt einen Meilenstein in der Geschichte der Chirurgie dar. Mit einigen Jahren Verzug folgten die Urogynäkologen den Chirurgen und begannen, Polypropylen-Netze zur Behebung von Beckenbodenvorfällen einzusetzen. PP910-Netze (Vypro II®, Ethicon und PP25-Netze (Ultrapro®, Ethicon werden seit Langem mit gutem Erfolg bei Hernien-Operationen eingesetzt. Das Ziel dieser Studie war herauszufinden, inwieweit sich diese beiden Netze auch für den Einsatz beim Beckenbodenprolaps eignen. Hierzu wurden Fragebögen an Patientinnen versandt, denen in den Jahren 2003 und 2004 diese Netze im Beckenboden implantiert wurden. Die Hauptfragestellungen waren hierbei, inwiefern sich die Symptome des Vorfalles nach der Behandlung verändert hatten und welche Komplikationen nach der Operation aufgetreten waren. Beide Gruppen zeigten nach dem Netzeinsatz deutliche Verbesserungen der Symptomatik bei einer geringen Komplikationsquote. Beim Einsatz von PP910 zeigten sich in 6 % der Fälle Komplikationen, die auf die Implantation des Netzes zurückgeführt werden konnten. Beim Einsatz von PP25 zeigten sogar nur 1,5 % der operierten Frauen netzbedingte Komplikationen. Somit hat sich gezeigt, dass beide Netze gut für die Verwendung im Beckenboden geeignet sind. Vergleicht man die beiden Netze mit anderen Produkten, die derzeit als Implantate im Beckenboden genutzt werden, so zeigt sich ein sehr positives Ergebnis mit signifikant weniger postoperativen Komplikationen unter der Verwendung von PP25-Netzen. Im Rahmen dieser Analyse konnte festgestellt werden, dass PP25 ein sehr sicheres Netz mit ausgesprochen guten Ergebnissen für die Therapie des Beckenbodenprolaps ist.

  16. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  17. R Ramaswamy

    Indian Academy of Sciences (India)

    More Details Fulltext PDF. Volume 19 Issue 1 January 2014 pp 1-2 General Editorial. General Editorial on Publication Ethics · R Ramaswamy · More Details Fulltext PDF. Volume 20 Issue 2 February 2015 pp 91-92. General Editorial on Publication Ethics · R Ramaswamy Rajaram Nityananda · More Details Fulltext PDF ...

  18. 26 CFR 1.165-10 - Wagering losses.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Wagering losses. 1.165-10 Section 1.165-10...) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.165-10 Wagering losses. Losses sustained during the taxable year on wagering transactions shall be allowed as a deduction but...

  19. Rate Processes in Dissipative Systems: 50 Years After Kramers, Discussion Meeting Held in Tutzing (Germany, F.R.) on 10-13 September 1990

    Science.gov (United States)

    1990-09-13

    Chem. Soc., Faraday Trans. [5] S. T. Abdel-Halim, M. H. Abdel-Kader, and U. E. Steiner , J. 2, 83, 1941 (1987), Phys. Chem 92, 4324 (1988). [29] W...December 5th, 1990) Zusammensetzung, Eigenschaften und Anwendungen Mesomorpher Tensidphasen RUDOLF HEUSCH Leverkusen, Paul-Klee-StraBe 85 (Received on...Institut f~r Anorganisehe Chemnie der Universitiit Rudower Chaussee 5, 0-1199 Physikalisehe Chemie) Rudolf - Bern, Freie Stra~e 3, CH-3000 Bern, be- Berlin

  20. 26 CFR 1.414(r)-8 - Separate application of section 410(b).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Separate application of section 410(b). 1.414(r)-8 Section 1.414(r)-8 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.414(r)-8...

  1. 75 FR 5167 - Office of Hazardous Materials Safety; Notice of Delays In Processing of Special Permits Applications

    Science.gov (United States)

    2010-02-01

    ... Trinity Industries, Inc. Dallas, TX 4 03-31-2010 14835-N The Reusable Industrial Packaging 4 03-31-2010..., GA. 14868-N Wal-Mart Stores, Inc. Bentonville, 4 03-31-2010 AR. 14861-N Gliko Aviation Inc. Belt, MT...

  2. Real-time ed end-point Polymerase Chain Reaction per la quantizzazione del DNA di Citomegalovirus: confronto tra metodi e con il test per l’antigene pp65

    Directory of Open Access Journals (Sweden)

    Tiziano Allice

    2006-03-01

    Full Text Available Quantitave Polymerase Chain Reaction (PCR for Cytomegalovirus (CMV DNA provides highly sensitive and specific data for detecting CMV as well as monitoring the infection and determining the appropriate antiviral strategy.To determine the clinical application of a recently introduced real-time (RT PCR assay for CMV DNA quantitation in peripheral blood leukocytes (PBLs and defining its correlation with the commercial quantitative end-point (EP PCR method COBAS AMPLICOR CMV Monitor and pp65 antigen test. Sequential PBL samples (n=158 from 32 liver transplanted patients with CMV asymptomatic infection and positive for CMV DNA by EP-PCR were retrospectively analysed with RT-PCR and studied according to pp65 antigen levels. A good correlation was found between RT-PCR and pp65 antigen test (r=0.691 and between the two PCR assays (r=0.761. RT-PCR data were significantly higher in pre-emptive treated patients (those with >20 pp65+positive cells, median value: 3.8 log10 copies/500,000 PBLs than in not-treated ones (2.9 logs.According to pp65 levels of 0, 1-10, 11-20, 21-50, 51-100 and >100 positive cells/200,000 PBLs, median CMV DNA load by RT-PCR was 2.6, 3.0, 3.6, 4.0. 4.2 and 4.8, log10 copies/ 500,000 PBLs, respectively (EP-PCR CMV DNA levels: 2. 8, 2.9, 3.8, 3.7, 3.9 and 4.0 logs. For samples with >20 pp65+cells, that is above the level at which pre-emptive therapy was started, RT-PCR values were significantly higher than in groups with less than 20 pp65+cells, whereas EP-PCR values did not significantly differ and showed a slower progression rate. Dilutions of DNA from CMV AD169 strain were used to probe RT-PCR reproducibility (between and intra-assay variability < 2% and sensitivity (100% detection rate at 10 copies/reaction, 28.5% with EP-PCR. A significant improvement is coming from the introduction of RT-PCR to the study of CMV DNA dynamics in differently CMV infected patients due to a more reliable quantitation of CMV DNA for moderate and high

  3. 26 CFR 1.857-10 - Information returns.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Information returns. 1.857-10 Section 1.857-10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.857-10 Information returns. Nothing in §§ 1.857-8 and 1...

  4. Anal sphincter complex: endoanal MR imaging of normal anatomy

    NARCIS (Netherlands)

    Hussain, S. M.; Stoker, J.; Laméris, J. S.

    1995-01-01

    To determine the normal anatomy of the anal sphincter complex on magnetic resonance (MR) images. Ten healthy volunteers (four men, six women; age range, 21-26 years) underwent MR imaging with an endoanal coil. The lower part of the anal canal contained the internal sphincter, the longitudinal muscle

  5. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  6. 75 FR 78800 - Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications

    Science.gov (United States)

    2010-12-16

    ... 4 03-31-2011 Industrial Packaging Assoc., Washington, DC. 14839-N Matheson Tn-Gas, 3 11-30-2010 Inc., Basking Ridge, NJ. 14851-N Alaska Airlines, 4 03-31-2011 Inc., Seattle, WA. 14868-N Wal-Mart Stores, 4 03...

  7. 75 FR 52057 - Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications

    Science.gov (United States)

    2010-08-24

    ... Trinity 4 03-31-2011 Industries, Inc., Dallas, TX. 14835-N The Reusable 4 03-31-2011 Industrial Packaging... Air 4 03-31-2011 Group, Inc., Seattle, WA. 14868-N Wal-Mart Stores, 4 03-31-2011 Inc., Bentonville, AR...

  8. Design and Construction Rules for Mechanical components of FBR nuclear islands: RCC-MR. Tome 1, Volume A: generalities

    International Nuclear Information System (INIS)

    1985-06-01

    The French Rules of Mechanical equipments of Fast Neutron nuclear Reactors (RCC-MR) aims at equipments included in a safety classification. The equipments concerned are those of the nuclear boiler and its auxiliaries: tanks, vessels, internal equipments of the reactor, exchangers, pumps, fittings, pipes, and supports. The present edition of the RCC-MR comprises 12 books presented in the present one in the volume A. The chapter RA 3000 defines the documents to be established in application of the RCC-MR rules. The chapter RA 5000 defines the requirements to take into account to establish and carry out quality Assurance programs according to the RCC-MR rules [fr

  9. Sedation of children for MR or CT imaging examination using chloral hydrate

    International Nuclear Information System (INIS)

    Song, Jong Gi; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo; Han, Man Chung

    1994-01-01

    Pediatric sedation is an important factor for obtaining the images of good quality. We performed this study to analyze the efficacy of our sedation protocol using chloral hydrate. We collected prospectively 151 sedation records of children(1 day-15 years old), who were sedated with chloral hydrate for MR(n=112) or CT(n=39) studies. We initially administered 50 mg/Kg orally(n=94) or rectally(n=57) 30 minutes before the scheduled examinations, and then administered additional dose (second dose: 25-35 mg/Kg, third dose: 10-15 mg/Kg) to patients whom initial dose failed to sedate. Satisfactory sedation was achieved by initial administration in 109 patients(72%) without significant difference between oral(per oral; P. O.) and rectal(per rectal: P.R.) administration. Second dose was required in 28% and third dose in 5%. MR and CT examinations required second dose in 36(32%) and 6 patients(15%), respectively. P.O. -patients vomited in 5%. P.R. -patients defecated in 22% after initial administration. There were no other serious complications. Time interval from the drug administration to the start of examinations was 33 minutes in initial-dose-group and 64 minutes in additional-dose-group. Two patients could not complete MR examination due to early arousal. Prolonged sedation, requiring more than 30 minutes for alertness after MR and CT examinations, was encountered in twenty(18%) and two patients(5%) respectively. Our protocol using chloral hydrate(P.O. or P.R.) is thought to be an effective and safe method for pediatric sedation for MR or CT imaging

  10. 10 CFR 26.85 - Collector qualifications and responsibilities.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Collector qualifications and responsibilities. 26.85 Section 26.85 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for... reports, if any; results of tests to establish employee competency for the position he or she holds...

  11. Decreased expression of miR-21, miR-26a, miR-29a, and miR-142-3p in CD4⁺ T cells and peripheral blood from tuberculosis patients.

    Science.gov (United States)

    Kleinsteuber, Katja; Heesch, Kerrin; Schattling, Stefanie; Kohns, Malte; Sander-Jülch, Claudia; Walzl, Gerhard; Hesseling, Anneke; Mayatepek, Ertan; Fleischer, Bernhard; Marx, Florian M; Jacobsen, Marc

    2013-01-01

    The vast majority of Mycobacterium tuberculosis (M. tuberculosis) infected individuals are protected from developing tuberculosis and T cells are centrally involved in this process. MicroRNAs (miRNA) regulate T-cell functions and are biomarker candidates of disease susceptibility and treatment efficacy in M. tuberculosis infection. We determined the expression profile of 29 selected miRNAs in CD4(+) T cells from tuberculosis patients and contacts with latent M. tuberculosis infection (LTBI). These analyses showed lower expression of miR-21, miR-26a, miR-29a, and miR-142-3p in CD4(+) T cells from tuberculosis patients. Whole blood miRNA candidate analyses verified decreased expression of miR-26a, miR-29a, and miR-142-3p in children with tuberculosis as compared to healthy children with LTBI. Despite marked variances between individual donor samples, trends of increased miRNA candidate expression during treatment and recovery were observed. Functional in vitro analysis identified increased miR-21 and decreased miR-26a expression after re-stimulation of T cells. In vitro polarized Interleukin-17 positive T-cell clones showed activation-dependent miR-29a up-regulation. In order to characterize the role of miR-29a (a described suppressor of Interferon-γ in tuberculosis), we analyzed M. tuberculosis specific Interferon-γ expressing T cells in children with tuberculosis and healthy contacts but detected no correlation between miR-29a and Interferon-γ expression. Suppression of miR-29a in primary human T cells by antagomirs indicated no effect on Interferon-γ expression after in vitro activation. Finally, classification of miRNA targets revealed only a moderate overlap between the candidates. This may reflect differential roles of miR-21, miR-26a, miR-29a, and miR-142-3p in T-cell immunity against M. tuberculosis infection and disease.

  12. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  13. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  14. Production of 26Al by spallation of Fe, Si, Al nuclei

    International Nuclear Information System (INIS)

    Paillard, P.

    1977-01-01

    Cross sections for 7 Be, 10 Be and 26 Al formation in Al, Si and Fe targets bombarded with 0.6 and 24GeV protons have been measured by using highly selective chemical separation and low level background counters. Results for 26 Al at 0.6GeV are in mb: 17.9 + or - 2.7 in Al, 12.5 + or - 2.5 in Si and 0.45 + or - 0.14 in Fe; at 24GeV 2.6 + or - 0.5mb in Fe. Results for 10 Be are not valid on account of experimental difficulties. It is deduced from these values of aluminium in cosmic ray propagation that 26 Al is not yet cosmic ray chronometer [fr

  15. 39 CFR 962.26 - Settlement.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Settlement. 962.26 Section 962.26 Postal Service... CIVIL REMEDIES ACT § 962.26 Settlement. (a) Either party may make offers of settlement or proposals of... settlement terms to the Attorney General, as appropriate. [59 FR 51860, Oct. 13, 1994] ...

  16. Measurement of the Inclusive W and Z Production Cross Sections in pp Collisions at $\\sqrt{s}$ = 7 TeV with the CMS experiment

    CERN Document Server

    Chatrchyan, Serguei; Sirunyan, Albert M; Tumasyan, Armen; Adam, Wolfgang; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Haensel, Stephan; Hoch, Michael; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kiesenhofer, Wolfgang; Krammer, Manfred; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rahbaran, Babak; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Teischinger, Florian; Wagner, Philipp; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Bansal, Sunil; Benucci, Leonardo; De Wolf, Eddi A; Janssen, Xavier; Maes, Thomas; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Devroede, Olivier; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Michael; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Charaf, Otman; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hammad, Gregory Habib; Hreus, Tomas; Marage, Pierre Edouard; Raval, Amita; Thomas, Laurent; Vander Velde, Catherine; Vanlaer, Pascal; Adler, Volker; Cimmino, Anna; Costantini, Silvia; Grunewald, Martin; Klein, Benjamin; Lellouch, Jérémie; Marinov, Andrey; Mccartin, Joseph; Ryckbosch, Dirk; Thyssen, Filip; Tytgat, Michael; Vanelderen, Lukas; Verwilligen, Piet; Walsh, Sinead; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Caudron, Julien; Ceard, Ludivine; Cortina Gil, Eduardo; De Favereau De Jeneret, Jerome; Delaere, Christophe; Favart, Denis; Giammanco, Andrea; Grégoire, Ghislain; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Nuttens, Claude; Ovyn, Severine; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Schul, Nicolas; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Alves, Gilvan; Brito, Lucas; De Jesus Damiao, Dilson; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Aldá Júnior, Walter Luiz; Carvalho, Wagner; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Silva Do Amaral, Sheila Mara; Sznajder, Andre; Bernardes, Cesar Augusto; De Almeida Dias, Flavia; Tomei, Thiago; De Moraes Gregores, Eduardo; Lagana, Caio; Da Cunha Marinho, Franciole; Mercadante, Pedro G; Novaes, Sergio F; Padula, Sandra; Darmenov, Nikolay; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Dimitrov, Anton; Hadjiiska, Roumyana; Karadzhinova, Aneliya; Kozhuharov, Venelin; Litov, Leander; Mateev, Matey; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Meng, Xiangwei; Tao, Junquan; Wang, Jian; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xiao, Hong; Xu, Ming; Zang, Jingjing; Zhang, Zhen; Ban, Yong; Guo, Shuang; Guo, Yifei; Li, Wenbo; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Zhu, Bo; Zou, Wei; Cabrera, Andrés; Gomez Moreno, Bernardo; Ocampo Rios, Alberto Andres; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Lelas, Karlo; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Dzelalija, Mile; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Finger, Miroslav; Finger Jr, Michael; Assran, Yasser; Ellithi Kamel, Ali; Khalil, Shaaban; Mahmoud, Mohammed; Hektor, Andi; Kadastik, Mario; Müntel, Mait; Raidal, Martti; Rebane, Liis; Tiko, Andres; Azzolini, Virginia; Eerola, Paula; Fedi, Giacomo; Czellar, Sandor; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Kortelainen, Matti J; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Karjalainen, Ahti; Korpela, Arja; Tuuva, Tuure; Sillou, Daniel; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Gentit, François-Xavier; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Marionneau, Matthieu; Millischer, Laurent; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Verrecchia, Patrice; Baffioni, Stephanie; Beaudette, Florian; Benhabib, Lamia; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Dahms, Torsten; Dobrzynski, Ludwik; Elgammal, Sherif; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Thiebaux, Christophe; Wyslouch, Bolek; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Greder, Sebastien; Juillot, Pierre; Karim, Mehdi; Le Bihan, Anne-Catherine; Mikami, Yoshinari; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Baty, Clement; Beauceron, Stephanie; Beaupere, Nicolas; Bedjidian, Marc; Bondu, Olivier; Boudoul, Gaelle; Boumediene, Djamel; Brun, Hugues; Chasserat, Julien; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Fay, Jean; Gascon, Susan; Ille, Bernard; Kurca, Tibor; Le Grand, Thomas; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sordini, Viola; Tosi, Silvano; Tschudi, Yohann; Verdier, Patrice; Lomidze, David; Anagnostou, Georgios; Beranek, Sarah; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Mohr, Niklas; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Weber, Martin; Wittmer, Bruno; Ata, Metin; Dietz-Laursonn, Erik; Erdmann, Martin; Hebbeker, Thomas; Heidemann, Carsten; Hinzmann, Andreas; Hoepfner, Kerstin; Klimkovich, Tatsiana; Klingebiel, Dennis; Kreuzer, Peter; Lanske, Dankfried; Lingemann, Joschka; Magass, Carsten; Merschmeyer, Markus; Meyer, Arnd; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Bontenackels, Michael; Davids, Martina; Duda, Markus; Flügge, Günter; Geenen, Heiko; Giffels, Manuel; Haj Ahmad, Wael; Heydhausen, Dirk; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Linn, Alexander; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Rennefeld, Jörg; Sauerland, Philip; Stahl, Achim; Thomas, Maarten; Tornier, Daiske; Zoeller, Marc Henning; Aldaya Martin, Maria; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Bethani, Agni; Borras, Kerstin; Cakir, Altan; Campbell, Alan; Castro, Elena; Dammann, Dirk; Eckerlin, Guenter; Eckstein, Doris; Flossdorf, Alexander; Flucke, Gero; Geiser, Achim; Hauk, Johannes; Jung, Hannes; Kasemann, Matthias; Katkov, Igor; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krämer, Mira; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Mankel, Rainer; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Olzem, Jan; Petrukhin, Alexey; Pitzl, Daniel; Raspereza, Alexei; Rosin, Michele; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Spiridonov, Alexander; Stein, Matthias; Tomaszewska, Justyna; Walsh, Roberval; Wissing, Christoph; Autermann, Christian; Blobel, Volker; Bobrovskyi, Sergei; Draeger, Jula; Enderle, Holger; Gebbert, Ulla; Görner, Martin; Hermanns, Thomas; Kaschube, Kolja; Kaussen, Gordon; Kirschenmann, Henning; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Naumann-Emme, Sebastian; Nowak, Friederike; Pietsch, Niklas; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schröder, Matthias; Schum, Torben; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Barth, Christian; Bauer, Julia; Berger, Joram; Buege, Volker; Chwalek, Thorsten; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Feindt, Michael; Gruschke, Jasmin; Hackstein, Christoph; Hartmann, Frank; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Honc, Simon; Komaragiri, Jyothsna Rani; Kuhr, Thomas; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Peiffer, Thomas; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Ratnikova, Natalia; Renz, Manuel; Saout, Christophe; Scheurer, Armin; Schieferdecker, Philipp; Schilling, Frank-Peter; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Wagner-Kuhr, Jeannine; Weiler, Thomas; Zeise, Manuel; Zhukov, Valery; Ziebarth, Eva Barbara; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Ntomari, Eleni; Petrakou, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Saoulidou, Niki; Stiliaris, Efstathios; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Triantis, Frixos A; Aranyi, Attila; Bencze, Gyorgy; Boldizsar, Laszlo; Hajdu, Csaba; Hidas, Pàl; Horvath, Dezso; Kapusi, Anita; Krajczar, Krisztian; Sikler, Ferenc; Veres, Gabor Istvan; Vesztergombi, Gyorgy; Beni, Noemi; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Veszpremi, Viktor; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Gupta, Ruchi; Jindal, Monika; Kaur, Manjit; Kohli, Jatinder Mohan; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Anil; Singh, Jasbir; Singh, Supreet Pal; Ahuja, Sudha; Choudhary, Brajesh C; Gupta, Pooja; Jain, Sandhya; Kumar, Ashok; Kumar, Arun; Naimuddin, Md; Ranjan, Kirti; Shivpuri, Ram Krishen; Banerjee, Sunanda; Bhattacharya, Satyaki; Dutta, Suchandra; Gomber, Bhawna; Jain, Shilpi; Khurana, Raman; Sarkar, Subir; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kumar, Vineet; Mehta, Pourus; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Guchait, Monoranjan; Gurtu, Atul; Maity, Manas; Majumder, Devdatta; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Saha, Anirban; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Mondal, Naba Kumar; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Hesari, Hoda; Jafari, Abideh; Khakzad, Mohsen; Mohammadi, Abdollah; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Manna, Norman; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pierro, Giuseppe Antonio; Pompili, Alexis; Pugliese, Gabriella; Romano, Francesco; Roselli, Giuseppe; Selvaggi, Giovanna; Silvestris, Lucia; Trentadue, Raffaello; Tupputi, Salvatore; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Giunta, Marina; Grandi, Claudio; Marcellini, Stefano; Masetti, Gianni; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gianni; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Gonzi, Sandro; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Gennai, Simone; Ghezzi, Alessio; Malvezzi, Sandra; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cavallo, Nicola; De Cosa, Annapaola; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Merola, Mario; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bellan, Paolo; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dorigo, Tommaso; Dosselli, Umberto; Fanzago, Federica; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Mazzucato, Mirco; Meneguzzo, Anna Teresa; Nespolo, Massimo; Perrozzi, Luca; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Vanini, Sara; Zotto, Pierluigi; Zumerle, Gianni; Baesso, Paolo; Berzano, Umberto; Ratti, Sergio P; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Viviani, Claudio; Biasini, Maurizio; Bilei, Gian Mario; Caponeri, Benedetta; Fanò, Livio; Lariccia, Paolo; Lucaroni, Andrea; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Romeo, Francesco; Santocchia, Attilio; Taroni, Silvia; Valdata, Marisa; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Palmonari, Francesco; Segneri, Gabriele; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Di Marco, Emanuele; Diemoz, Marcella; Franci, Daniele; Grassi, Marco; Longo, Egidio; Meridiani, Paolo; Nourbakhsh, Shervin; Organtini, Giovanni; Pandolfi, Francesco; Paramatti, Riccardo; Rahatlou, Shahram; Rovelli, Chiara; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Botta, Cristina; Cartiglia, Nicolo; Castello, Roberto; Costa, Marco; Demaria, Natale; Graziano, Alberto; Mariotti, Chiara; Marone, Matteo; Maselli, Silvia; Migliore, Ernesto; Mila, Giorgia; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Potenza, Alberto; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Sola, Valentina; Solano, Ada; Staiano, Amedeo; Vilela Pereira, Antonio; Belforte, Stefano; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Montanino, Damiana; Penzo, Aldo; Heo, Seong Gu; Nam, Soon-Kwon; Chang, Sunghyun; Chung, Jin Hyuk; Kim, Dong Hee; Kim, Gui Nyun; Kim, Ji Eun; Kong, Dae Jung; Park, Hyangkyu; Ro, Sang-Ryul; Son, Dong-Chul; Son, Taejin; Kim, Jaeho; Kim, Jae Yool; Song, Sanghyeon; Choi, Suyong; Hong, Byung-Sik; Jo, Mihee; Kim, Hyunchul; Kim, Ji Hyun; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Sim, Kwang Souk; Choi, Minkyoo; Kang, Seokon; Kim, Hyunyong; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Kim, Min Suk; Lee, Byounghoon; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Martisiute, Dalia; Petrov, Pavel; Polujanskas, Mindaugas; Sabonis, Tomas; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-de La Cruz, Ivan; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Sánchez-Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A; Krofcheck, David; Tam, Jason; Butler, Philip H; Doesburg, Robert; Silverwood, Hamish; Ahmad, Muhammad; Ahmed, Ijaz; Asghar, Muhammad Irfan; Hoorani, Hafeez R; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Brona, Grzegorz; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Almeida, Nuno; Bargassa, Pedrame; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Musella, Pasquale; Nayak, Aruna; Pela, Joao; Ribeiro, Pedro Quinaz; Seixas, Joao; Varela, Joao; Afanasiev, Serguei; Belotelov, Ivan; Golutvin, Igor; Kamenev, Alexey; Karjavin, Vladimir; Kozlov, Guennady; Lanev, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Savina, Maria; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Vorobyev, Andrey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Toropin, Alexander; Troitsky, Sergey; Epshteyn, Vladimir; Gavrilov, Vladimir; Kaftanov, Vitali; Kossov, Mikhail; Krokhotin, Andrey; Lychkovskaya, Natalia; Popov, Vladimir; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Kodolova, Olga; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Rusakov, Sergey V; Vinogradov, Alexey; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Korablev, Andrey; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cepeda, Maria; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Diez Pardos, Carmen; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Vizan Garcia, Jesus Manuel; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Jorda, Clara; Lobelle Pardo, Patricia; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Piedra Gomez, Jonatan; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Sobron Sanudo, Mar; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bell, Alan James; Benedetti, Daniele; Bernet, Colin; Bialas, Wojciech; Bloch, Philippe; Bocci, Andrea; Bolognesi, Sara; Bona, Marcella; Breuker, Horst; Bunkowski, Karol; Camporesi, Tiziano; Cerminara, Gianluca; Christiansen, Tim; Coarasa Perez, Jose Antonio; Curé, Benoît; D'Enterria, David; De Roeck, Albert; Di Guida, Salvatore; Dupont-Sagorin, Niels; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Gaddi, Andrea; Georgiou, Georgios; Gerwig, Hubert; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Glege, Frank; Gomez-Reino Garrido, Robert; Gouzevitch, Maxime; Govoni, Pietro; Gowdy, Stephen; Guiducci, Luigi; Hansen, Magnus; Hartl, Christian; Harvey, John; Hegeman, Jeroen; Hegner, Benedikt; Hoffmann, Hans Falk; Honma, Alan; Innocente, Vincenzo; Janot, Patrick; Kaadze, Ketino; Karavakis, Edward; Lecoq, Paul; Lourenco, Carlos; Maki, Tuula; Malberti, Martina; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Maurisset, Aurelie; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Nesvold, Erik; Nguyen, Matthew; Orimoto, Toyoko; Orsini, Luciano; Palencia Cortezon, Enrique; Perez, Emmanuelle; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Piparo, Danilo; Polese, Giovanni; Racz, Attila; Reece, William; Rodrigues Antunes, Joao; Rolandi, Gigi; Rommerskirchen, Tanja; Rovere, Marco; Sakulin, Hannes; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sharma, Archana; Siegrist, Patrice; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Spiropulu, Maria; Stoye, Markus; Tropea, Paola; Tsirou, Andromachi; Vichoudis, Paschalis; Voutilainen, Mikko; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Starodumov, Andrei; Bäni, Lukas; Bortignon, Pierluigi; Caminada, Lea; Casal, Bruno; Chanon, Nicolas; Chen, Zhiling; Cittolin, Sergio; Dissertori, Günther; Dittmar, Michael; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Hintz, Wieland; Lecomte, Pierre; Lustermann, Werner; Marchica, Carmelo; Martinez Ruiz del Arbol, Pablo; Milenovic, Predrag; Moortgat, Filip; Nägeli, Christoph; Nef, Pascal; Nessi-Tedaldi, Francesca; Pape, Luc; Pauss, Felicitas; Punz, Thomas; Rizzi, Andrea; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Sawley, Marie-Christine; Stieger, Benjamin; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Matthias; Wehrli, Lukas; Weng, Joanna; Aguilo, Ernest; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Otiougova, Polina; Robmann, Peter; Schmidt, Alexander; Snoek, Hella; Chang, Yuan-Hann; Chen, Kuan-Hsin; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Zong-Kai; Lu, Yun-Ju; Mekterovic, Darko; Volpe, Roberta; Wu, Jing-Han; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wang, Minzu; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Hos, Ilknur; Kangal, Evrim Ersin; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Uzun, Dilber; Vergili, Latife Nukhet; Vergili, Mehmet; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilin, Bugra; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yildirim, Eda; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Demir, Durmus; Gülmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Özbek, Melih; Ozkorucuklu, Suat; Sonmez, Nasuf; Levchuk, Leonid; Bostock, Francis; Brooke, James John; Cheng, Teh Lee; Clement, Emyr; Cussans, David; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Hartley, Dominic; Heath, Greg P; Heath, Helen F; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J; Basso, Lorenzo; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Camanzi, Barbara; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Jackson, James; Kennedy, Bruce W; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R; Womersley, William John; Worm, Steven; Bainbridge, Robert; Ball, Gordon; Ballin, Jamie; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Davies, Gavin; Della Negra, Michel; Ferguson, William; Fulcher, Jonathan; Futyan, David; Gilbert, Andrew; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Jarvis, Martyn; Karapostoli, Georgia; Lyons, Louis; MacEvoy, Barry C; Magnan, Anne-Marie; Marrouche, Jad; Mathias, Bryn; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rogerson, Samuel; Rompotis, Nikolaos; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sharp, Peter; Sparrow, Alex; Tapper, Alexander; Tourneur, Stephane; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardle, Nicholas; Wardrope, David; Whyntie, Tom; Barrett, Matthew; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leslie, Dawn; Martin, William; Reid, Ivan; Teodorescu, Liliana; Hatakeyama, Kenichi; Liu, Hongxuan; Henderson, Conor; Bose, Tulika; Carrera Jarrin, Edgar; Fantasia, Cory; Heister, Arno; St John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Avetisyan, Aram; Bhattacharya, Saptaparna; Chou, John Paul; Cutts, David; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Landsberg, Greg; Luk, Michael; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Sinthuprasith, Tutanon; Speer, Thomas; Tsang, Ka Vang; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Friis, Evan; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Liu, Haidong; Maruyama, Sho; Miceli, Tia; Nikolic, Milan; Pellett, Dave; Robles, Jorge; Salur, Sevil; Schwarz, Thomas; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Veelken, Christian; Andreev, Valeri; Arisaka, Katsushi; Cline, David; Cousins, Robert; Deisher, Amanda; Duris, Joseph; Erhan, Samim; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Jarvis, Chad; Plager, Charles; Rakness, Gregory; Schlein, Peter; Tucker, Jordan; Valuev, Vyacheslav; Babb, John; Chandra, Avdhesh; Clare, Robert; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Kao, Shih-Chuan; Liu, Feng; Liu, Hongliang; Long, Owen Rosser; Luthra, Arun; Nguyen, Harold; Paramesvaran, Sudarshan; Shen, Benjamin C; Stringer, Robert; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G; Cerati, Giuseppe Benedetto; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Mangano, Boris; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pi, Haifeng; Pieri, Marco; Ranieri, Riccardo; Sani, Matteo; Sharma, Vivek; Simon, Sean; Sudano, Elizabeth; Tadel, Matevz; Tu, Yanjun; Vartak, Adish; Wasserbaech, Steven; Würthwein, Frank; Yagil, Avraham; Yoo, Jaehyeok; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; Vlimant, Jean-Roch; Apresyan, Artur; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Gataullin, Marat; Ma, Yousi; Mott, Alexander; Newman, Harvey B; Rogan, Christopher; Shin, Kyoungha; Timciuc, Vladlen; Traczyk, Piotr; Veverka, Jan; Wilkinson, Richard; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Jun, Soon Yung; Liu, Yueh-Feng; Paulini, Manfred; Russ, James; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Dinardo, Mauro Emanuele; Drell, Brian Robert; Edelmaier, Christopher; Ford, William T; Gaz, Alessandro; Heyburn, Bernadette; Luiggi Lopez, Eduardo; Nauenberg, Uriel; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Zang, Shi-Lei; Agostino, Lorenzo; Alexander, James; Chatterjee, Avishek; Eggert, Nicholas; Gibbons, Lawrence Kent; Heltsley, Brian; Henriksson, Kristofer; Hopkins, Walter; Khukhunaishvili, Aleko; Kreis, Benjamin; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Puigh, Darren; Ryd, Anders; Saelim, Michael; Salvati, Emmanuele; Shi, Xin; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Biselli, Angela; Cirino, Guy; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Apollinari, Giorgio; Atac, Muzaffer; Bakken, Jon Alan; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bloch, Ingo; Borcherding, Frederick; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Cooper, William; Eartly, David P; Elvira, Victor Daniel; Esen, Selda; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Gottschalk, Erik; Green, Dan; Gunthoti, Kranti; Gutsche, Oliver; Hanlon, Jim; Harris, Robert M; Hirschauer, James; Hooberman, Benjamin; Jensen, Hans; Johnson, Marvin; Joshi, Umesh; Khatiwada, Rakshya; Klima, Boaz; Kousouris, Konstantinos; Kunori, Shuichi; Kwan, Simon; Leonidopoulos, Christos; Limon, Peter; Lincoln, Don; Lipton, Ron; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Mason, David; McBride, Patricia; Miao, Ting; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Pivarski, James; Pordes, Ruth; Prokofyev, Oleg; Sexton-Kennedy, Elizabeth; Sharma, Seema; Spalding, William J; Spiegel, Leonard; Tan, Ping; Taylor, Lucas; Tkaczyk, Slawek; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; Das, Souvik; De Gruttola, Michele; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Hugon, Justin; Kim, Bockjoo; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Low, Jia Fu; Matchev, Konstantin; Mitselmakher, Guenakh; Muniz, Lana; Prescott, Craig; Remington, Ronald; Rinkevicius, Aurelijus; Schmitt, Michael Houston; Scurlock, Bobby; Sellers, Paul; Skhirtladze, Nikoloz; Snowball, Matthew; Wang, Dayong; Yelton, John; Zakaria, Mohammed; Gaultney, Vanessa; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F; Prosper, Harrison; Quertenmont, Loic; Sekmen, Sezen; Veeraraghavan, Venkatesh; Baarmand, Marc M; Dorney, Brian; Guragain, Samir; Hohlmann, Marcus; Kalakhety, Himali; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Callner, Jeremy; Cavanaugh, Richard; Dragoiu, Cosmin; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Khalatyan, Samvel; Kunde, Gerd J; Lacroix, Florent; Malek, Magdalena; O'Brien, Christine; Silkworth, Christopher; Silvestre, Catherine; Smoron, Agata; Strom, Derek; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Clarida, Warren; Duru, Firdevs; Lae, Chung Khim; McCliment, Edward; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bonato, Alessio; Eskew, Christopher; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Tran, Nhan Viet; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Grachov, Oleg; Kenny Iii, Raymond Patrick; Murray, Michael; Noonan, Daniel; Sanders, Stephen; Wood, Jeffrey Scott; Zhukova, Victoria; Barfuss, Anne-fleur; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Wan, Zongru; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Eno, Sarah Catherine; Ferencek, Dinko; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G; Kirn, Malina; Lu, Ying; Mignerey, Alice; Rossato, Kenneth; Rumerio, Paolo; Santanastasio, Francesco; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C; Twedt, Elizabeth; Alver, Burak; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Everaerts, Pieter; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Harris, Philip; Kim, Yongsun; Klute, Markus; Lee, Yen-Jie; Li, Wei; Loizides, Constantinos; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Stöckli, Fabian; Sumorok, Konstanty; Sung, Kevin; Velicanu, Dragos; Wenger, Edward Allen; Wolf, Roger; Xie, Si; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cooper, Seth; Cushman, Priscilla; Dahmes, Bryan; De Benedetti, Abraham; Dudero, Phillip Russell; Franzoni, Giovanni; Gude, Alexander; Haupt, Jason; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Pastika, Nathaniel; Rekovic, Vladimir; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Tambe, Norbert; Cremaldi, Lucien Marcus; Godang, Romulus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Summers, Don; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R; Dominguez, Aaron; Eads, Michael; Jindal, Pratima; Keller, Jason; Kelly, Tony; Kravchenko, Ilya; Lazo-Flores, Jose; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R; Baur, Ulrich; Godshalk, Andrew; Iashvili, Ia; Jain, Supriya; Kharchilava, Avto; Kumar, Ashish; Shipkowski, Simon Peter; Smith, Kenneth; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Boeriu, Oana; Chasco, Matthew; Reucroft, Steve; Swain, John; Trocino, Daniele; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Brinkerhoff, Andrew; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Kolberg, Ted; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Wayne, Mitchell; Ziegler, Jill; Bylsma, Ben; Durkin, Lloyd Stanley; Gu, Jianhui; Hill, Christopher; Killewald, Phillip; Kotov, Khristian; Ling, Ta-Yung; Rodenburg, Marissa; Vuosalo, Carl; Williams, Grayson; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hunt, Adam; Laird, Edward; Lopes Pegna, David; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Safdi, Ben; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Acosta, Jhon Gabriel; Huang, Xing Tao; Lopez, Angel; Mendez, Hector; Oliveros, Sandra; Ramirez Vargas, Juan Eduardo; Zatserklyaniy, Andriy; Alagoz, Enver; Barnes, Virgil E; Bolla, Gino; Borrello, Laura; Bortoletto, Daniela; De Mattia, Marco; Everett, Adam; Garfinkel, Arthur F; Gutay, Laszlo; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Kress, Matthew; Laasanen, Alvin T; Leonardo, Nuno; Liu, Chang; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Parashar, Neeti; Adair, Antony; Boulahouache, Chaouki; Ecklund, Karl Matthew; Geurts, Frank JM; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Flacher, Henning; Garcia-Bellido, Aran; Goldenzweig, Pablo; Gotra, Yury; Han, Jiyeon; Harel, Amnon; Miner, Daniel Carl; Orbaker, Douglas; Petrillo, Gianluca; Sakumoto, Willis; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Malik, Sarah; Mesropian, Christina; Atramentov, Oleksiy; Barker, Anthony; Duggan, Daniel; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hits, Dmitry; Lath, Amitabh; Panwalkar, Shruti; Patel, Rishi; Rose, Keith; Schnetzer, Steve; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Eusebi, Ricardo; Flanagan, Will; Gilmore, Jason; Gurrola, Alfredo; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Osipenkov, Ilya; Pakhotin, Yuriy; Safonov, Alexei; Sengupta, Sinjini; Tatarinov, Aysen; Toback, David; Weinberger, Michael; Akchurin, Nural; Bardak, Cemile; Damgov, Jordan; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Libeiro, Terence; Mane, Poonam; Roh, Youn; Sill, Alan; Volobouev, Igor; Wigmans, Richard; Yazgan, Efe; Appelt, Eric; Brownson, Eric; Engh, Daniel; Florez, Carlos; Gabella, William; Issah, Michael; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Cox, Bradley; Francis, Brian; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Yohay, Rachel; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Lamichhane, Pramod; Mattson, Mark; Milstène, Caroline; Sakharov, Alexandre; Anderson, Michael; Bachtis, Michail; Bellinger, James Nugent; Carlsmith, Duncan; Dasu, Sridhara; Efron, Jonathan; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Reeder, Don; Ross, Ian; Savin, Alexander; Smith, Wesley H; Swanson, Joshua; Weinberg, Marc

    2011-01-01

    A measurement of inclusive W and Z production cross sections in pp collisions at sqrt(s)=7 TeV is presented. The electron and muon decay channels are analyzed in a data sample collected with the CMS detector at the LHC and corresponding to an integrated luminosity of 36 inverse picobarns. The measured inclusive cross sections are sigma(pp-> WX) B(W-> l nu) = 10.30 +/- 0.02 (stat.) +/- 0.10 (syst.) +/- 0.10 (th.) +/- 0.41 (lumi.) nb and sigma(pp -> ZX) B(Z-> l^+l^-) = 0.974 +/- 0.007 (stat.) +/- 0.007 (syst.) +/- 0.018 (th.) +/- 0.039 (lumi.) nb, limited to the dilepton invariant mass range 60 to 120 GeV. The luminosity-independent cross section ratios are [sigma(pp->WX) B(W-> l nu)]/[sigma(pp-> ZX) B(Z->l^+l^-)] = 10.54 +/- 0.07 (stat.) +/- 0.08 (syst.) +/- 0.16 (th.) and [sigma(pp->W^+X) B(W^+ -> l^+nu)] / [sigma(pp->W^- X) +B(W^- -> l^- nu)] = 1.421 +/- 0.006 (stat.) +/- 0.014 (syst.) +/- 0.029 (th.). -> The measured values agree with next-to-next-to-leading order QCD cross section calculations based on r...

  17. Study of charm meson production in Tip and pp interactions at 360 Gev/c

    International Nuclear Information System (INIS)

    Etienne, F.

    1984-02-01

    The available energy at accelerators of SPS Type, implies the development of new experimental technics and firet of all their optimization by simulation program. A set of programs has been written to evaluate and improve the performances of the spectrometer EHS (European Hybrid Spectrometer) at C.E.R.N. In 1979, the main components of the spectrometer are ready to be used in an experiment allowing the direct observation of charm decays. Charm D meson production in 360 GeV π - p and pp interactions has been studied using the high resolution Hydrogen bubble chamber LEBC and EHS. The production cross sections are computed. The date show evidence for leading quark effect in the Feynman x distribution in the π - p sample. The rapidity gap between members of reconstructed charm pairs is small compared to the available rapidity range in the π - p sample although no strong correlation is observed between DantiD pairs in the pp sample. Finally the data are compared to other experimental results and checked to the predictions of the models of charm hadro-production in a kinematical region very different from the one of leptons pairs production at high Psub(t) where perturbative QCD applies [fr

  18. 10 CFR 26.61 - Self-disclosure and employment history.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Self-disclosure and employment history. 26.61 Section 26... Authorization § 26.61 Self-disclosure and employment history. (a) Before granting authorization, the licensee or other entity shall ensure that a written self-disclosure and employment history has been obtained from...

  19. The effect of recycled Natural Rubber Glove (rRG) Plasticizers to Deflection and Flexural Strength Properties of PP/MMt/rRG Smart Composites and Its Inflammability

    Science.gov (United States)

    Suharty, N. S.; Ismail, H.; Diharjo, K.; Handayani, D. S.; Saputri, L. N. M. Z.; Ariesta, N.

    2018-03-01

    Had been synthesized PP/rRG/MMt+ZB smart material composite in solution reactive processes with various rRG concentration. The addition of rRG plasticizers will improve the deflection properties and increase the filler capacity MMt loading to reach the optimum concentration. The addition of 3% rRG is capable of loading filler capacity MMt to 23% as the optimum condition. At the optimum conditions it can increase the deflection (Defl) and flexural strength (FS) up to 16% and 15% respectively compared to that of the composites without rRG. The rRG plasticizer serves as a bio-compatibilizer that can reduce surface tension of the mixture and leads to decrease the Defl., follow by the increase of loading filler capacity and well interaction finally can increase the FS properties. The increase of loading filler MMt up to 23% can also improve the inflammability of the composites. Time to Ignition (TTI) increase by 5% and Burning Rate (BR) decrease by 4.5% compared to that of the composites which is containing MMt 20% without rRG.

  20. Lanthanum Containing Polymer's Modification to PP

    Institute of Scientific and Technical Information of China (English)

    Dai Shaojun; Zhang Ming

    2004-01-01

    Polypropylene (PP)'s low impact strength limits its usages. Adding some a rare earth polymer can enhance PP's tensile strength and impact strength. Acrylic lanthanum was prepared by the reaction between lanthanum oxide and acrylic acid. The IR spectrum prove that and optimum reacting conditions are that the bulk ratio of La(AA) 3 and MMA is not less than one and temperature is about 80 ℃. Lanthanum containing Polymer were added into PP. When percent of addition only was 3%, strength were enhanced 10% , and impact strength 40%. SEM shows the compatibility of rare earth polymer and PP; lanthanum containing polymer can form physical crosslinking between PP's molecules, then every particle's surface connect with several PP molecules and the PP mechanical property were enhanced.

  1. 77 FR 65545 - Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption

    Science.gov (United States)

    2012-10-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 4815-009] Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption 1. By application filed on July 30, 2012 and supplemented on August 14, 2012, Mr. Jesse S. Capel and Mr. Hilton J. Cochran and EWP...

  2. Monte Carlo determinations of the functions Λ(r, Z), G(r, θ), g(R) and F(r, θ) for Amersham CDCS-M-type 137Cs source

    International Nuclear Information System (INIS)

    Valdez, F. Roberto Fragoso; Alvarez Romero, J. Trinidad

    2001-01-01

    The functions Λ(r, z), G(r, θ), g(r) and F(r, θ) were calculated for Amersham model CDCS-M-type 137 Cs source by means of Monte Carlo simulation using the algorithm PENELOPE. These functions are required to verify and/or to feed planning systems or directly as entrance data for the manual planning of the distribution of absorbed dose according with the recommendations of the TG 43, [1]. The values of the constant Λ (r, Z) were determined as the quotient of absorbed dose rate distribution in water and air kerma strength in 'free air' S k . The values obtained for Λ (r, Z) differ up to 3% of those reported in the literature, being very sensitive to the cutoff energy for the electrons in the interface of the source's encapsulated and water

  3. 26Al, a cosmic ray imprit for the past million years

    International Nuclear Information System (INIS)

    Reyss, J.-L.

    1978-03-01

    In this work a long-life cosmonuclide: 26 Al (T 1/2 = 7.15x10 5 years) has been studied, particularly its applications to geophysical research. Two different approaches have been taken: evaluation of the relative importances of the different sources of 26 Al: lithosphere, atmosphere and cosmic dust; measurements of 26 Al in pelagic sediments and Greenland ices. The results show that 26 Al of surface sediments is essentially of atmospheric origin, other contributions being unimportant. This conclusion is the more interesting as another cosmonuclide of similar origin exists: 10 Be (1.5x10 6 years, twice that of 26 Al). The measured ratios 26 Al/ 10 Be in the sediments, in a Greenland ice sample and at the surface of a polymetallic crust are in agreement with theoretical ratios calculated from the atmospheric production. These two cosmomuclides have the same history for their formation and for their geochemical behaviour and it is therefore proposed to us them for absolute dating in the marine environment [fr

  4. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1992-12-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author).

  5. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    International Nuclear Information System (INIS)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi

    1992-01-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author)

  6. MR myelography of sacral meningeal cysts

    International Nuclear Information System (INIS)

    Tsuchiya, K.; Katase, S.; Hachiya, J.

    1999-01-01

    Purpose: To describe the findings of sacral meningeal cysts (SMCs) on MR myelography and assess its value for the diagnosis of SMCs. Material and Methods: We evaluated the MR images and MR myelograms obtained from 10 patients with SMC. MR myelograms were obtained using a 2D or 3D single-shot fast spin-echo sequence. In 5 patients, X-ray myelograms and postmyelographic CT images were compared with the MR myelograms. Results: A total of 33 SMCs were diagnosed within the spinal canal and/or sacral foramen. MR myelograms clearly revealed each cyst as a well-defined mass showing hyperintensity (10 cysts) or isointensity (23 cysts) compared to cerebrospinal fluid. MR myelograms demonstrated SMCs better than X-ray myelograms and postmyelographic CT images in 3 of the 5 patients. Conclusion: MR myelography can be an adjunct to conventional imaging techniques when surgical treatment is indicated, because it can precisely delineate the extent of SMCs. (orig.)

  7. MR-guided microwave ablation in hepatic tumours: initial results in clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Ruediger; Rempp, Hansjoerg; Kessler, David-Emanuel; Weiss, Jakob; Nikolaou, Konstantin; Clasen, Stephan [Eberhard-Karls-University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Pereira, Philippe L. [SLK-Kliniken Heilbronn GmbH, Department of Radiology, Minimally Invasive Therapies and Nuclear Medicine, Heilbronn (Germany)

    2017-04-15

    Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. (orig.)

  8. Hepatic iron overload: Quantitative MR imaging

    International Nuclear Information System (INIS)

    Gomori, J.M.; Horev, G.; Tamary, H.; Zandback, J.; Kornreich, L.; Zaizov, R.; Freud, E.; Krief, O.; Ben-Meir, J.; Rotem, H.

    1991-01-01

    Iron deposits demonstrate characteristically shortened T2 relaxation times. Several previously published studies reported poor correlation between the in vivo hepatic 1/T2 measurements made by means of midfield magnetic resonance (MR) units and the hepatic iron content of iron-overloaded patients. In this study, the authors assessed the use of in vivo 1/T2 measurements obtained by means of MR imaging at 0.5 T using short echo times (13.4 and 30 msec) and single-echo-sequences as well as computed tomographic (CT) attenuation as a measure of liver iron concentration in 10 severely iron-overloaded patients with beta-thalassemia major. The iron concentrations in surgical wedge biopsy samples of the liver, which varied between 3 and 9 mg/g of wet weight (normal, less than or equal to 0.5 mg/g), correlated well (r = .93, P less than or equal to .0001) with the preoperative in vivo hepatic 1/T2 measurements. The CT attenuation did not correlate with liver iron concentration. Quantitative MR imaging is a readily available noninvasive method for the assessment of hepatic iron concentration in iron-overloaded patients, reducing the need for needle biopsies of the liver

  9. Early evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Zhou, Nan; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Guo, Tingting; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian

    2016-01-01

    Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and

  10. Nonlinear evolution of f(R) cosmologies. II. Power spectrum

    International Nuclear Information System (INIS)

    Oyaizu, Hiroaki; Hu, Wayne; Lima, Marcos

    2008-01-01

    We carry out a suite of cosmological simulations of modified action f(R) models where cosmic acceleration arises from an alteration of gravity instead of dark energy. These models introduce an extra scalar degree of freedom which enhances the force of gravity below the inverse mass or Compton scale of the scalar. The simulations exhibit the so-called chameleon mechanism, necessary for satisfying local constraints on gravity, where this scale depends on environment, in particular, the depth of the local gravitational potential. We find that the chameleon mechanism can substantially suppress the enhancement of power spectrum in the nonlinear regime if the background field value is comparable to or smaller than the depth of the gravitational potentials of typical structures. Nonetheless power spectrum enhancements at intermediate scales remain at a measurable level for models even when the expansion history is indistinguishable from a cosmological constant, cold dark matter model. Simple scaling relations that take the linear power spectrum into a nonlinear spectrum fail to capture the modifications of f(R) due to the change in collapsed structures, the chameleon mechanism, and the time evolution of the modifications.

  11. MR findings of brainstem injury

    Energy Technology Data Exchange (ETDEWEB)

    Park, Man Soo; Hwang, Woo Cheol; Park, Choong Ki [Hallym University College of Medicine, Seoul (Korea, Republic of); Suh, Dae Chul [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Sang Joon [Dankook University of College of Medicine, Cheonan (Korea, Republic of)

    1995-02-15

    To analyze the characteristics of traumatic brainstem injury by CT and MR. CT and MR studies of 10 patients with traumatic brainstem lesion in MR were retrospectively reviewed, particularly attended to location, signal intensity and associated lesions. CT failed to depict 8 of 10 brainstem lesions. All lesions were detected in MR images with T2-weighted images showing higher detection rate (n = 10) (100%) than T1-weighted images (n = 3) (30%) or CT (n = 2) (20%). The brainstem lesions located in the dorsolateral aspects of the rostral brainstem (mid brain and upper pons) in 7 (70%) cases, in ventral aspects of rostral brain in 2 (20%) cases and in median portion of pons in 1 (10%) case. Corpus callosal (n = 5), lobar white matter (n = 5) diffuse axonal injury, and 2 hemorrhagic lesions in basal ganglia were the associated findings. MR imaging is more helpful than CT in the detection of brainstem injury, especially T2 weighted images. Primary brainstem lesions were typically located in the dorsolateral aspect of rostral brainstem (midbrain and upper pons). Corpus callosum and white matter lesions were frequently associated.

  12. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    Science.gov (United States)

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  13. Spherically Symmetric Geometries in f(T) and f(R) Gravitational Theories

    International Nuclear Information System (INIS)

    Nashed, Gamal G. L.

    2015-01-01

    Using the well know relation between Ricci scalar, R, and torsion scalar, T, that is, R=-T-2∇_αT"α, we show that, for any spherically symmetric spacetime whose (i) scalar torsion vanishing, that is, T=T_μ_ν"αS_α"μ"ν=0 or (ii) total derivative term, that is, ∇_αT"α with T"α is the contraction of the torsion, vanishing, or (iii) the combination of scalar torsion and total derivative term vanishing, could be solution for f(T) and f(R) gravitational theories.

  14. Rotavirus 2/6 Viruslike Particles Administered Intranasally with Cholera Toxin, Escherichia coli Heat-Labile Toxin (LT), and LT-R192G Induce Protection from Rotavirus Challenge

    OpenAIRE

    O’Neal, Christine M.; Clements, John D.; Estes, Mary K.; Conner, Margaret E.

    1998-01-01

    We have shown that rotavirus 2/6 viruslike particles composed of proteins VP2 and VP6 (2/6-VLPs) administered to mice intranasally with cholera toxin (CT) induced protection from rotavirus challenge, as measured by virus shedding. Since it is unclear if CT will be approved for human use, we evaluated the adjuvanticity of Escherichia coli heat-labile toxin (LT) and LT-R192G. Mice were inoculated intranasally with 10 μg of 2/6-VLPs combined with CT, LT, or LT-R192G. All three adjuvants induced ...

  15. MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Huang, Jie; Xu, Yujun; He, Xiangmeng; Lue, Yubo; Liu, Qiang; Li, Chengli [Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong (China); Li, Lei [Qingdao Central Hospital, Department of Interventional Radiology, Qingdao, Shandong (China); Blanco Sequeiros, Roberto [Turku University Hospital, The South Western Finland Imaging Centre, Turku (Finland)

    2017-04-15

    To prospectively evaluate the feasibility, safety and accuracy of MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open MR scanner with respiratory gating. Sixty-five patients with 65 solitary pulmonary lesions underwent MR-guided percutaneous coaxial cutting needle biopsy using a 1.0-T open MR scanner with respiratory gating. Lesions were divided into two groups according to maximum lesion diameters: ≤2.0 cm (n = 31) and >2.0 cm (n = 34). The final diagnosis was established in surgery and subsequent histology. Diagnostic accuracy, sensitivity and specificity were compared between the groups using Fisher's exact test. Accuracy, sensitivity and specificity of MRI-guided percutaneous pulmonary biopsy in diagnosing malignancy were 96.9 %, 96.4 % and 100 %, respectively. Accuracy, sensitivity and specificity were 96.8 %, 96.3 % and 100 % for lesions 2.0 cm or smaller and 97.1 %, 96.4 % and 100 %, respectively, for lesions larger than 2.0 cm. There was no significant difference between the two groups (P > 0.05). Biopsy-induced complications encountered were pneumothorax in 12.3 % (8/65) and haemoptysis in 4.6 % (3/65). There were no serious complications. MRI-guided percutaneous biopsy using a 1.0-T open MR scanner with respiratory gating is an accurate and safe diagnostic technique in evaluation of pulmonary lesions. (orig.)

  16. Prostate cancer: a comparative study of {sup 11}C-choline PET and MR imaging combined with proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Takako; Lee, Jin; Takahashi, Nobukazu; Oka, Takashi; Shizukuishi, Kazuya; Inoue, Tomio [Yokohama City University School of Medicine, Department of Radiology, Yokohama (Japan); Uemura, Hiroji; Kubota, Yoshinobu [Yokohama City University School of Medicine, Department of Urology, Kanagawa (Japan); Sasaki, Takeshi [Yokohama City University School of Medicine, Department of Pathology, Kanagawa (Japan); Endou, Hisashi [Yokohama City University School of Medicine, Department of Pharmacy, Kanagawa (Japan)

    2005-07-01

    Prostate cancer is difficult to visualise in its early stages using current imaging technology. The present study aimed to clarify the utility of {sup 11}C-choline PET for localising and evaluating cancer lesions in patients with prostate cancer by conducting a prospective comparison with magnetic resonance (MR) imaging combined with proton MR spectroscopy. PET and MR imaging combined with proton MR spectroscopy were performed in 20 patients with prostate cancer. Correlations among the metabolite ratio of choline + creatine to citrate (Cho+Cr/Ci) on MR spectroscopy, serum PSA and maximum standardised uptake value (SUV{sub max}) of {sup 11}C-choline were assessed. The location of the primary lesion was assessed by the site of SUV{sub max} and the laterality of the highest Cho+Cr/Ci ratio and confirmed by examination of surgical pathology specimens (n=16). PET exhibited a diagnostic sensitivity of 100% (20/20) for primary lesions, while the sensitivities of MR imaging and MR spectroscopy were 60% (12/20) and 65% (13/20), respectively. Weak linear correlations were observed between SUV{sub max} and serum PSA (r=0.52, p<0.05), and between SUV{sub max} and Cho+Cr/Ci ratio (r=0.49, p<0.05). Regarding the localisation of main primary lesions, PET results agreed with pathological findings in 13 patients (81%) ({kappa}=0.59), while MR spectroscopy results were in accordance with pathological findings in eight patients (50%) ({kappa}=0.11). This preliminary study suggests that {sup 11}C-choline PET may provide more accurate information regarding the localisation of main primary prostate cancer lesions than MR imaging/MR spectroscopy. A further clinical study of {sup 11}C-choline PET in a large number of patients suspected of prostate cancer will be necessary to determine the clinical utility of {sup 11}C-choline PET in patients who clinically require biopsy. (orig.)

  17. Generic f(R) theories and classicality of their scalarons

    Energy Technology Data Exchange (ETDEWEB)

    Gannouji, Radouane [Department of Physics, Faculty of Science, Tokyo University of Science, 1-3, Kagurazaka, Shinjuku-ku, Tokyo 162-8601 (Japan); Sami, M., E-mail: samijamia@gmail.com [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Thongkool, I. [Harish-Chandra Research Institute, Chhatnag Road, Jhusi, Allahabad-211019 (India)

    2012-09-19

    We study quantum stability bound on the mass of scalaron in generic theories of f(R) gravity. We show that in these scenarios, the scalaron mass increases faster with local density of the environment than one-loop quantum correction to it thereby leading to violation of quantum bound on the chameleon mass. The introduction of quadratic curvature corrections in the action are shown to stabilize the model.

  18. R K Laxman

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R K Laxman. Articles written in Resonance – Journal of Science Education. Volume 1 Issue 4 April 1996 pp 4-4 Science Smiles. Chief Editor's column / Science Smiles · R K Laxman · More Details Fulltext PDF. Volume 1 Issue 5 May 1996 pp 3-3 Science Smiles.

  19. 15th June 2009-His Excellency Mr Lech Kaczyński,President of the Republic of Poland,visiting CMS Experiment

    CERN Multimedia

    Maximilien Brice

    2009-01-01

    Tirage 1;16-17:First Lady,H.E. M. KACZYŃSKA,President of the Republic of Poland,H.E. L. KACZYŃSKI with Technology Department,Machine Protection & Electrical Integrity Group Leader,A.Siemko Tirage 2;10:CMS Collaboration Spokesperson,T. Virdee with H.E. M. KACZYŃSKA,H.E. L. KACZYŃSKI and Coordinator for External Relations,F. Pauss visiting CMS experimental area Tirage 3:Representative of the French Republic,Sous-Préfet de Gex,Mr O. Laurens-Bernard and H.E. L. KACZYŃSKI Tirage 6 to 9:Signature of the Guest book with the Director-General,R. Heuer Tirage 11-12:the delegation visiting CMS experimental area Tirage 18-26:H.E. L. KACZYŃSKI with Polish scientists at CERN

  20. Using Noether symmetries to specify f(R) gravity

    International Nuclear Information System (INIS)

    Paliathanasis, Andronikos

    2013-01-01

    A detailed study of the modified gravity, f(R) models is performed, using the fact that the Noether point symmetries of these models are geometric symmetries of the mini su-perspace of the theory. It is shown that the requirement that the field equations admit Noether point symmetries selects definite models in a self-consistent way. As an application in Cosmology we consider the Friedman -Robertson-Walker spacetime and show that the only cosmological model which is integrable via Noether point symmetries is the (R b − 2Λ) c model, which generalizes the Lambda Cosmology. Furthermore using the corresponding Noether integrals we compute the analytic form of the main cosmological functions

  1. MR imaging and CT findings after liver transplantation

    International Nuclear Information System (INIS)

    Langer, M.; Langer, R.; Scholz, A.; Zwicker, C.; Astinet, F.

    1990-01-01

    The aim of the paper is to evaluate MR imaging and dynamic CT as noninvasive procedures to image signs of graft failure after an orthotopic liver transplantation (OLT). Thirty MR studies and 50 dynamic CT examinations were performed within 20 days after OLT. MR examinations were performed with a 0.5-T Siemens Magnetom. CT scans were obtained by using a Siemens Somatom Plus. In all patients, MR images demonstrated a perivascular rim of intermediate signal intensity on T1-weighted and increased signal intensity on T2-weighted images in the hilum of the liver; in 20/26, this was seen in peripheral areas also. In all patients, a perivascular area of low attenuation was diagnosed at angio-CT

  2. R-R interval variations influence the degree of mitral regurgitation in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Moller, J. E.; Haggstrom, J.

    2014-01-01

    of congestive heart failure due to MMVD. The severity of MR was evaluated in apical four-chamber view using colour Doppler flow mapping (maximum % of the left atrium area) and colour Doppler M-mode (duration in ms). The influence of the ratio between present and preceding R-R interval on MR severity......Mitral regurgitation (MR) due to myxomatous mitral valve disease (MMVD) is a frequent finding in Cavalier King Charles Spaniels (CKCSs). Sinus arrhythmia and atrial premature complexes leading to R-R interval variations occur in dogs. The aim of the study was to evaluate whether the duration...... of the RR interval immediately influences the degree of MR assessed by echocardiography in dogs. Clinical examination including echocardiography was performed in 103 privately-owned dogs: 16 control Beagles, 70 CKCSs with different degree of MR and 17 dogs of different breeds with clinical signs...

  3. Bone marrow changes on STIR MR images of asymptomatic feet and ankles

    International Nuclear Information System (INIS)

    Zubler, Veronika; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Duc, Sylvain R.; Schmid, Marius R.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of this study was to evaluate the prevalence, pattern and size of bone marrow changes on short-tau inversion recovery (STIR) magnetic resonance (MR) images of asymptomatic feet and ankles. In 78 asymptomatic volunteers (41 women, 37 men; median age 47 years; range 23-83 years) sagittal STIR MR images of hindfoot and midfoot were reviewed for various patterns of high signal changes in bone marrow. The size of these bone marrow changes was measured, and signal intensity was rated semi-quantitatively using a scale from 0 (=normal) to 10 (=fluid-like). Fifty percent (39/78) of all volunteers had at least one bone marrow change. Thirty-six percent (28/78) of all volunteers had edema-like changes, 26% (20/78) had necrosis-like changes, and 5% (4/78) had cyst-like changes. The long diameters of all changes varied between 4 mm and 16 mm (median 7.5 mm). The median signal intensity for all changes was 5.0 (range 1-10). Bone marrow changes on STIR MR images are commonly detected in asymptomatic feet and ankles. However, such changes tend to be small (<1 cm) or subtle. (orig.)

  4. Rotavirus 2/6 Viruslike Particles Administered Intranasally with Cholera Toxin, Escherichia coli Heat-Labile Toxin (LT), and LT-R192G Induce Protection from Rotavirus Challenge

    Science.gov (United States)

    O’Neal, Christine M.; Clements, John D.; Estes, Mary K.; Conner, Margaret E.

    1998-01-01

    We have shown that rotavirus 2/6 viruslike particles composed of proteins VP2 and VP6 (2/6-VLPs) administered to mice intranasally with cholera toxin (CT) induced protection from rotavirus challenge, as measured by virus shedding. Since it is unclear if CT will be approved for human use, we evaluated the adjuvanticity of Escherichia coli heat-labile toxin (LT) and LT-R192G. Mice were inoculated intranasally with 10 μg of 2/6-VLPs combined with CT, LT, or LT-R192G. All three adjuvants induced equivalent geometric mean titers of rotavirus-specific serum antibody and intestinal immunoglobulin G (IgG). Mice inoculated with 2/6-VLPs with LT produced significantly higher titers of intestinal IgA than mice given CT as the adjuvant. All mice inoculated with 2/6-VLPs mixed with LT and LT-R192G were totally protected (100%) from rotavirus challenge, while mice inoculated with 2/6-VLPs mixed with CT showed a mean 91% protection from challenge. The availability of a safe, effective mucosal adjuvant such as LT-R192G will increase the practicality of administering recombinant vaccines mucosally. PMID:9525668

  5. MO-FG-BRA-09: Quantification of Nanoparticle Heating and Concentration for MR-Guided Laser Interstitial Thermal Therapy

    International Nuclear Information System (INIS)

    MacLellan, CJ; Melancon, M; Fuentes, D; Stafford, RJ; Salatan, F; Yang, Q; Hwang, KP

    2015-01-01

    Purpose: Nanoparticle Mediated Laser Interstitial Thermal Therapy (npLITT) is a technique that utilizes tumor localized optically activated nanoparticles to increase the conformality of laser ablation procedures. Temperatures in these procedures are dependent on the particle concentration which generally cannot be measured noninvasively prior to therapy. In this work we attempt to quantify particle concentration in vivo by estimating the increase in R2* relaxation induced by bifunctional magnetic resonance (MR)-visible gold-based nanoparticles (SPIO@Au) and relate it to the temperature increase observed during real time MR temperature imaging (MRTI) of laser ablation. Methods: SPIO@Au nanoparticles (90nm) were synthesized containing a silica-iron core (for MR visibility via R2*) and gold shell (for near-infrared absorption). High resolution R2* maps were acquired before and after injecting four different particle concentrations (saline,1e10, 5e10, and 10e10 particles/mL) into HN5 flank xenografts. Tumors were monitored using MRTI during treatment with an interstitial fiber. (1 watt, 808 nm, 3 minutes) Results: The maximum temperature within the tumors increased linearly with concentration of injected particles, reaching 34.0, 37.6, 45.8, and 55.4 "0C for saline, 1e10, 5e10 and 10e10 particles/mL injections, respectively (R2=.994). The highest temperatures occur at the injection site rather than the fiber, confirming that SPIO@Au nanoparticles are the primary absorber. The differences between the median R2* measured at the injection site and the rest of the tumor were −6, 134, 111, 156 s-1 for the saline,1e10,5e10 and 10e10 particles/mL injections, respectively. This R2* change is consistent with the measured relaxivity for the 1e10 particles/mL injection but does not maintain linearity at higher concentrations. Conclusion: Bifunctional SPIO@Au nanoparticles are a promising technology for providing noninvasive estimates of particle concentration via MRI and

  6. pp and ̄pp elastic scattering

    Directory of Open Access Journals (Sweden)

    A. Donnachie

    1984-01-01

    Full Text Available We present an analysis of pp and ̄pp elastic scattering in terms of various exchanges. Three-gluon exchange dominates at large t, and single-pomeron exchange at small t. The dip seen in high-energy pp scattering is provided by the interference of both of these with double-pomeron exchange. We predict that this dip will not be found in high-energy ̄pp scattering. The dip that is seen in low-energy ̄pp scattering is the result of the additional presence of reggeon-pomeron exchange.

  7. miR-10 in development and cancer

    DEFF Research Database (Denmark)

    Lund, Anders Henrik

    2010-01-01

    The microRNA (miRNA) miR-10 family has attracted attention because of its conservation and the position of the miR-10 genes within the Hox clusters of developmental regulators. In several species, miR-10 is coexpressed with a set of Hox genes and has been found to regulate the translation of Hox ...... function to the miRNA repertoire.Cell Death and Differentiation advance online publication, 22 May 2009; doi:10.1038/cdd.2009.58....

  8. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  9. Measurement of skeletal muscle area: Comparison of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinelnikov, Andrey, E-mail: sinelnikovas@upmc.edu [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Qu, Chuanxing [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Fetzer, David T. [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Pelletier, Jean-Sébastien [Department of Surgery, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Dunn, Michael A. [Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Tsung, Allan [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Furlan, Alessandro [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-10-15

    Objective: To investigate the intra- and inter-observer agreement and correlation between CT and MR measurements of skeletal muscle area (SMA) in the abdomen. Methods: CT and MR images from twelve patients were analyzed by two blinded observers using segmentation software (MITK-3M3, Mint Medical and Slice-O-Matic, Tomovision) to quantify SMA. MR images included T1w “in-phase”, T1w “out-of-phase”, and T2w sequences. Inter- and intra-observer agreement was assessed using the intraclass correlation coefficient (ICC). Pearson correlation coefficient (r) was used to correlate measurements obtained on MR with CT. CT and MR measurements were compared with Bland-Altman plots. Results: Intra- and inter-observer agreement for SMA was high for CT and MR. For MR, the measurements on T2w images showed the highest inter-observer agreement (ICC = 0.96). CT SMA correlated closely with MR, with T2w images showing the highest correlation (r = 0.98; P < 0.01). Bland-Altman plots showed a 1.7%–3.9% bias between CT and MR measurements, lowest for T2w images. Conclusions: MR SMA measurements are reproducible and correlate closely with CT. The T2w sequence is recommended to quantify SMA on MR images.

  10. Thick brane in f(R) gravity with Palatini dynamics

    International Nuclear Information System (INIS)

    Bazeia, D.; Losano, L.; Menezes, R.; Olmo, Gonzalo J.; Rubiera-Garcia, D.

    2015-01-01

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R)=R+ϵR n , where the small parameter ϵ controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections

  11. Thick brane in f(R) gravity with Palatini dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bazeia, D., E-mail: bazeia@fisica.ufpb.br; Losano, L., E-mail: losano@fisica.ufpb.br [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Menezes, R., E-mail: rmenezes@dce.ufpb.br [Departamento de Ciências Exatas, Universidade Federal da Paraíba, 58297-000, Rio Tinto, PB (Brazil); Departamento de Física, Universidade Federal de Campina Grande, 58109-970, Campina Grande, PB (Brazil); Olmo, Gonzalo J., E-mail: gonzalo.olmo@csic.es [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Departamento de Física Teórica, IFIC, Centro Mixto Universidad de Valencia-CSIC, Universidad de Valencia, 46100, Burjassot, Valencia (Spain); Rubiera-Garcia, D., E-mail: drgarcia@fc.ul.pt [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Faculdade de Ciências, Instituto de Astrofísica e Ciências do Espaço, Universidade de Lisboa, Campo Grande, 1749-016, Lisbon (Portugal); Department of Physics, Center for Field Theory and Particle Physics, Fudan University, 220 Handan Road, 200433, Shanghai (China)

    2015-11-30

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R)=R+ϵR{sup n}, where the small parameter ϵ controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections.

  12. P-barp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    International Nuclear Information System (INIS)

    Islam, M.M.; Fearnley, T.; Guillaud, J.P.

    1984-01-01

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range √s approx. (10-1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in p-barp and pp differential cross-sections. As energy increases beyond the ISR range (√s = (23-62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between p-barp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of p-barp and pp differential cross-sections at future collider energies √s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the p-barp differential cross-section at the ISR and SPS collider in the abs (t)-range (0.5-2.0) (GeV) 2 is stressed

  13. P-barp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.M. (Connecticut Univ., Storrs (USA). Dept. of Physics); Fearnley, T. (University Coll., London (UK). Dept. of Physics and Astronomy); Guillaud, J.P. (L.A.P.P. - BP909, 74019 Annecy-Le-Vieux Cedex, France)

    1984-06-21

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range ..sqrt..s approx. (10-1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in p-barp and pp differential cross-sections. As energy increases beyond the ISR range (..sqrt..s = (23-62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between p-barp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of p-barp and pp differential cross-sections at future collider energies ..sqrt..s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the p-barp differential cross-section at the ISR and SPS collider in the abs (t)-range (0.5-2.0) (GeV)/sup 2/ is stressed.

  14. Up-regulation of miR-26a promotes apoptosis of hypoxic rat neonatal cardiomyocytes by repressing GSK-3β protein expression.

    Science.gov (United States)

    Suh, Jong Hui; Choi, Eunmi; Cha, Min-Ji; Song, Byeong-Wook; Ham, Onju; Lee, Se-Yeon; Yoon, Cheesoon; Lee, Chang-Yeon; Park, Jun-Hee; Lee, Sun Hee; Hwang, Ki-Chul

    2012-06-29

    Myocardial ischemia is the major cause of morbidity and mortality due to cardiovascular diseases. This disease is a severe stress condition that causes extensive biochemical changes which trigger cardiac cell death. Stress conditions such as deprivation of glucose and oxygen activate the endoplasmic reticulum in the cytoplasm of cells, including cardiomyocytes, to generate and propagate apoptotic signals in response to these conditions. microRNAs (miRNAs) are a class of small non-coding RNAs that mediate posttranscriptional gene silencing. The miRNAs play important roles in regulating cardiac physiological and pathological events such as hypertrophy, apoptosis, and heart failure. However, the roles of miRNAs in reactive oxygen species (ROS)-mediated injury on cardiomyocytes are uncertain. In this study, we identified at the apoptotic concentration of H(2)O(2), miR-26a expression was increased. To determine the potential roles of miR-26a in H(2)O(2)-mediated cardiac apoptosis, miR-26a expression was regulated by a miR-26a or an anti-miR-26a. Overexpression of miR-26a increased apoptosis as determined by upregulation of Annexin V/PI positive cell population, caspase-3 activity and expression of pro-apoptotic signal molecules, whereas inhibition of miR-26a reduced apoptosis. We identified GSK3B as a direct downstream target of miR-26a. Furthermore, miR-26a attenuated viability and increased caspase-3 activity in normal cardiomyocytes. This study demonstrates that miR-26a promotes ROS-induced apoptosis in cardiomyocytes. Thus, miR-26a affects ROS-mediated gene regulation and cellular injury response. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Official Guard and Reserve Manpower Strengths and Statistics. FY 2002 Summary

    Science.gov (United States)

    2002-01-01

    printed annually for each fiscal year. Comments concerned with policy issues of use of these reports for Reserve Component studies should be...34- <o rt LT1 0)OCT) CNCD <Din-TTf 01 N Or; X3 *f !D O) IO 91 Cil CD »- ^ a n « ninao «- S©e)»CMcMr»ej»m N... POLICY BOARD 5 OASD (MM&PP) (O&EPM) 1 OASD (HAI(MR) (MP&T) 1 OASD (FM&P) (MM&PP) (AP) 1 OASD/RAIM&P) 20 OASD (FM&P) (R&R) (TFR) 5 OASD (FM&P

  16. Coordinate phosphorylation of insulin-receptor kinase and its 175,000-Mr endogenous substrate in rat hepatocytes

    International Nuclear Information System (INIS)

    Okamoto, M.; Karasik, A.; White, M.F.; Kahn, C.R.

    1991-01-01

    To investigate the early events in insulin signal transmission in liver, isolated rat hepatocytes were labeled with 32 P, and proteins phosphorylated in response to insulin were detected by immunoprecipitation with anti-phosphotyrosine and anti-receptor antibodies and analyzed by sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis and autoradiography. In these cells, insulin rapidly stimulated tyrosine phosphorylation of the 95,000-Mr beta-subunit of the insulin receptor and a 175,000-Mr phosphoprotein (pp175). Both proteins were precipitated by anti-phosphotyrosine antibody, whereas only the insulin receptor was recognized with anti-insulin-receptor antibody. In the insulin-stimulated state, both pp175 and the receptor beta-subunit were found to be phosphorylated on tyrosine and serine residues. Based on precipitation by the two antibodies, receptor phosphorylation was biphasic with an initial increase in tyrosine phosphorylation followed by a more gradual increase in serine phosphorylation over the first 30 min of stimulation. The time course of phosphorylation of pp175 was rapid and paralleled that of the beta-subunit of the insulin receptor. The pp175 was clearly distinguished from the insulin receptor, because it was detected only when boiling SDS was used to extract cellular phosphoproteins, whereas the insulin receptor was extracted with either Triton X-100 or SDS. In addition, the tryptic peptide maps of the two proteins were distinct. The dose-response curve for insulin stimulation was shifted slightly to the left of the insulin receptor, suggesting some signal amplification at this step. These data suggest that pp175 is a major endogenous substrate of the insulin receptor in liver and may be a cytoskeletal-associated protein

  17. Proton range shift analysis on brain pseudo-CT generated from T1 and T2 MR.

    Science.gov (United States)

    Pileggi, Giampaolo; Speier, Christoph; Sharp, Gregory C; Izquierdo Garcia, David; Catana, Ciprian; Pursley, Jennifer; Amato, Francesco; Seco, Joao; Spadea, Maria Francesca

    2018-05-29

    In radiotherapy, MR imaging is only used because it has significantly better soft tissue contrast than CT, but it lacks electron density information needed for dose calculation. This work assesses the feasibility of using pseudo-CT (pCT) generated from T1w/T2w MR for proton treatment planning, where proton range comparisons are performed between standard CT and pCT. MR and CT data from 14 glioblastoma patients were used in this study. The pCT was generated by using conversion libraries obtained from tissue segmentation and anatomical regioning of the T1w/T2w MR. For each patient, a plan consisting of three 18 Gy beams was designed on the pCT, for a total of 42 analyzed beams. The plan was then transferred onto the CT that represented the ground truth. Range shift (RS) between pCT and CT was computed at R 80 over 10 slices. The acceptance threshold for RS was according to clinical guidelines of two institutions. A γ-index test was also performed on the total dose for each patient. Mean absolute error and bias for the pCT were 124 ± 10 and -16 ± 26 Hounsfield Units (HU), respectively. The median and interquartile range of RS was 0.5 and 1.4 mm, with highest absolute value being 4.4 mm. Of the 42 beams, 40 showed RS less than the clinical range margin. The two beams with larger RS were both in the cranio-caudal direction and had segmentation errors due to the partial volume effect, leading to misassignment of the HU. This study showed the feasibility of using T1w and T2w MRI to generate a pCT for proton therapy treatment, thus avoiding the use of a planning CT and allowing better target definition and possibilities for online adaptive therapies. Further improvements of the methodology are still required to improve the conversion from MRI intensities to HUs.

  18. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Liu, M; Hearshen, D; Brown, S; Siddiqui, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable

  19. 10 CFR 26.77 - Management actions regarding possible impairment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Management actions regarding possible impairment. 26.77... Sanctions To Be Imposed § 26.77 Management actions regarding possible impairment. (a) This section defines... alcohol with no other behavioral or physical indications of impairment, then only an alcohol test is...

  20. Slug-tests in PP- and PVP-holes at Olkiluoto in 2008

    International Nuclear Information System (INIS)

    Keskitalo, K.

    2009-02-01

    As part of the program for the final disposal of the nuclear fuel waste, Posiva Oy investigates the hydrological conditions at the Olkiluoto island. The hydraulic conductivity in the shallow holes OL-PP36, OL-PP39, OL-PVP4A, OL-PVP4B, OL-PVP6A, OL-PVP6B, OL-PVP14, OL-PVP21, OL-PVP22, OL-PVP23, OL-PVP24, OL-PVP25, OL-PVP26, OL-PVP27, OL-PVP28, OL-PVP29, OL-HP1, OL-HP2 and OL-HP4 was measured in summer 2008. The length of PP-holes was between 12 and 14 m, and the test sections (1 m) are located in the bedrock. PVP-tubes have an average length between 3 - 11 m, and the test sections (mostly 2 m) are located in the overburden. The measurements were done using the slug-test technique. In the slug-test, the hydraulic head in the borehole is abruptly changed either by pouring water into the borehole or by lowering the pressure sensor. The hydraulic conductivity is interpreted from the recovery of the water level. This report presents the field measurements and their interpretation. The interpretation has been done using the Hvorslev's method, and for reference, conductivity has also been calculated according to Thiem's equation. According to the results, hydraulic conductivity in PP-holes ranges from 10 -9 m/s to 10 -6 m/s and in PVP-tubes from 10 -8 m/s to 10 -5 m/s. The observed range is similar as in the previous measurements in 2002 and 2004 - 2007. In general, the results are consistent with the results obtained in earlier measurements. In OL-PVP14, there seems to be a lowering trend of the conductivity. In OL-PVP4A the results seem to have slight increase year after year. Also, the results agree with hydraulic conductivity interpreted from the pre-pumping done in connection with the groundwater sampling or installation of observation tubes. (orig.)

  1. Investigating the little rip and other future singularities of the universe, and validity of the second law of thermodynamics in F(R theory

    Directory of Open Access Journals (Sweden)

    M Aghaei Abchouyeh

    2015-01-01

    Full Text Available The future singularities are possible in a universe that is described by F(R theory. In previous studies the occurrence of the singularities in F(R theory have been considered by using a special function for the Hubble parameter and calculating the F(R function for each of the singularities. Using the specified Hubble parameter causes some difficulties in the study of the second law of thermodynamics. In this paper by using the scale factor, the behavior of F(R function near each type of the singularities is considered. We can check the validity of the second law of thermodynamics near the singularities. At first we study the Little Rip and then the other types of singularities are considered. The results show that the second law of thermodynamics is satisfied near the singularity type (I with some special conditions and is violated with some other conditions. it is satisfied near the Little Rip, type (II, (III and (IV singularities

  2. 75 FR 4383 - Pesticide Products: Registration Applications

    Science.gov (United States)

    2010-01-27

    ..., Biopesticides and Pollution Prevention Division (7511P), Office of Pesticide Programs, Environmental Protection..., Biopesticides and Pollution Prevention Division, Office of Pesticide Programs. [FR Doc. 2010-1582 Filed 1-26-10...

  3. 26 CFR 53.4943-10 - Business enterprise; definition.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 17 2010-04-01 2010-04-01 false Business enterprise; definition. 53.4943-10...) MISCELLANEOUS EXCISE TAXES (CONTINUED) FOUNDATION AND SIMILAR EXCISE TAXES Taxes on Excess Business Holdings § 53.4943-10 Business enterprise; definition. (a) In general. (1) Except as provided in paragraph (b...

  4. 10 CFR 26.65 - Pre-access drug and alcohol testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Pre-access drug and alcohol testing. 26.65 Section 26.65... § 26.65 Pre-access drug and alcohol testing. (a) Purpose. This section contains pre-access testing... days. If an individual has negative results from drug and alcohol tests that were conducted under the...

  5. Study of pp{yields}pp{eta} reaction at threshold; Etude de la reaction pp{yields}pp{eta} au seuil

    Energy Technology Data Exchange (ETDEWEB)

    Taleb, A

    1994-11-01

    The {eta} production has been studied through the pp {yields} pp{eta} reaction at threshold. Data were taken at the Synchrotron of the ``Laboratoire National Saturne``. The detection in coincidence of the two protons scattered near 0 deg and analysed with the magnetic spectrometer SPES3 allows the reconstruction of missing mass spectra for the {eta} signature. A simulation program which takes into account all the experimental set up characteristics has been realized and tested through the pp {yields} d{pi}{sup +} reaction detected simultaneously with pp {yields} pp{eta}. The generated proton momentum spectra for pp {yields} pp{eta} show a pronounced {eta} mass dependence. This characteristic, connected to the kinematical properties of pp {yields} pp{eta} at threshold, is used to extract the mass of the meson {eta}. The obtained value, m{sub {eta}} = 547.65 {+-} 0.18 MeV, is in good agreement with measurement done recently through the pd {yields} {sup H}e{eta} reaction. The total cross section {sigma}{sub t} of pp {yields} pp{eta} measured at 1260, 1265 and 1300 MeV presents a strong energy dependence. This cross section increases less with energy than the phase-space. The influence of p-p and {eta}-p final state interactions in our measurements is studied. Our results are compared with theoretical predictions and assess the dominant character of the baryonic resonance N{sup *}(1535) in the {eta} mechanism production at threshold. These experimental results give an energy dependence which is not well reproduced by the theoretical predictions. This discrepancy could be an incorrect description of the {eta}-p interaction in the models. (author). 48 refs., 60 figs., 15 tabs.

  6. Properties of PP/MWCNT-COOH /PP composites made by melt mixing versus solution cast /melt mixing methods

    International Nuclear Information System (INIS)

    Reinholds, I; Roja, Z; Zicans, J; Meri, R Merijs; Bitenieks, J

    2015-01-01

    An approach on improvement of the properties of polypropylene / carbon nanotube (PP/CNT) composites is reported. PP blend compositions with carboxylic acid functionalized multi-walled carbon nanotubes (MWCNT-COOH) at filler content 1.0 wt.% were researched. One part of the composites was manufactured by direct thermoplastic mixing PP with the filler, but the other one was made from solution casted masterbatch with the following thermoplastic mixing. An increase of mechanical properties (Young's modulus, storage modulus and tensile strength), compared to an increase of glass transition temperature indicated a reinforcement effect of CNTs on PP matrix, determined from the tensile tests and differential mechanical analysis (DMA), while the elongation was reduced, compared to PP matrix. By differential scanning calorimetry (DSC) analysis, the effect of nanofiller on the reorganization of PP crystallites was observed. A noticeable enhanced effect on increase of the crystallization temperature was indicated for masterbatch manufactured composite. An increase of thermal stability was also observed, compared to pristine PP and the composite made by direct thermoplastic mixing PP with the filler

  7. 77 FR 50090 - Update to the 26 September 2011 Military Freight Traffic Unified Rules Publication (MFTURP) NO. 1

    Science.gov (United States)

    2012-08-20

    ... DEPARTMENT OF DEFENSE Department of the Army Update to the 26 September 2011 Military Freight Traffic Unified Rules Publication (MFTURP) NO. 1 AGENCY: Department of the Army, DoD. SUMMARY: [email protected]us.army.mil . FOR FURTHER INFORMATION CONTACT: Mr. Chad Privett, (618) 220-6901...

  8. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  9. Message from Mr. R.A. Al-Kital, Commissioner of the Iraqi Atomic Energy Commission, received by the Director General on 23 October 1985

    International Nuclear Information System (INIS)

    1985-10-01

    The document reproduces the message from Mr. R.A. Al-Kital, Commissioner of the Iraqi Atomic Energy Commission received by the Director General of the IAEA on 23 October 1985 related to the Israeli attack against the Iraqi nuclear installations

  10. MR in phenylketonuria-related brain lesions

    Czech Academy of Sciences Publication Activity Database

    Dezortová, M.; Hájek, M.; Tintěra, J.; Hejcmanová, L.; Syková, Eva

    2001-01-01

    Roč. 42, - (2001), s. 459-466 ISSN 0284-1851 R&D Projects: GA ČR GV309/97/K048; GA ČR GA309/99/0657; GA MŠk VS96130 Institutional research plan: CEZ:AV0Z5039906 Keywords : brain phenylketonuria MR imaging Subject RIV: FH - Neurology Impact factor: 0.914, year: 2001

  11. MR augmented cardiopulmonary exercise testing—a novel approach to assessing cardiovascular function

    International Nuclear Information System (INIS)

    Barber, Nathaniel J; Ako, Emmanuel O; Kowalik, Grzegorz T; Steeden, Jennifer A; Muthurangu, Vivek; Pandya, Bejal

    2015-01-01

    The purposes of this study were: (1) to evaluate feasibility and acceptability of MRI augmented cardiopulmonary exercise testing (MR-CPET) in healthy adults and (2) to test whether peak values obtained at conventional and MR-CPET correlate and to demonstrate variation in peak oxygen consumption (VO_2) relates to both peak cardiac output (CO) and peak oxygen extraction (ΔcO_2). Seventeen healthy adults underwent CPET and MR-CPET using an MR compatible ergometer and CPET system customised for MR use. Continuous aortic flow measurement used a validated UNFOLD-SENSE spiral phase contrast magnetic resonance (PCMR) sequence.Fifteen of 17 volunteers completed exercise; exclusions were due to claustrophobia and inability to effectively master exercise technique. Measures of acceptability were lower but still satisfactory for MR-CPET.There were strong correlations between conventional and MR-CPET for peak VO_2 (r = 0.94, p < 0.001); VCO_2 (r = 0.87, p < 0.001) and VE (r = 0.88, p < 0.001).Multiple linear regression analysis demonstrated peak CO and ΔcO_2 were independent predictors of peak VO_2 measured during MR-CPET (β = 0.73 and 0.38 p < 0.0001) and conventional CPET (β = 0.78, 0.28 p < 0.0001).MR-CPET is feasible, acceptable and demonstrates physiology not apparent with conventional CPET. MR-CPET allows differentiation of the contributions of CO and ΔcO_2 to variation in peak VO_2. We believe that this will be useful in understanding the origin of reduced exercise capacity in cardiac disease. (note)

  12. 10 CFR 26.101 - Conducting a confirmatory test for alcohol.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting a confirmatory test for alcohol. 26.101 Section... Testing § 26.101 Conducting a confirmatory test for alcohol. (a) The confirmatory test must begin as soon... that meets the requirements of § 26.91(b) and (c) was used for the initial alcohol test, the same EBT...

  13. 17 CFR 10.26 - Motions and other papers.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Motions and other papers. 10... PRACTICE Institution of Adjudica- tory Proceedings; Pleadings; Motions § 10.26 Motions and other papers. (a...) the authority relied upon. If a motion is supported by briefs, affidavits or other papers, they shall...

  14. Clinical Investigation Program, RCS MED-300 (R1)

    Science.gov (United States)

    1987-10-31

    cholesterolemai. J Fam Pract 1987; 24:54-56. Manness DL, Rogers DY: Hemorrhagic complications of varicella . Am FP Feb 1987; pp. 151-155. Madlon-Kay 0J...carotid artery occlusion. Hospital Central Militar, Mexico City, Mexico , Jun 1987, Ebert FR: Ipsilateral concomitant fractures of femoral neck and femoral

  15. MR imaging in chronic epicondylitis humeri radialis at 1.0 T: is Gd-DTPA administration useful?; MRT bei chronischer Epicondylitis humeri radialis an einem 1,0 T-Geraet - Kontrastmittelgabe notwendig?

    Energy Technology Data Exchange (ETDEWEB)

    Herber, S.; Kalden, P.; Kreitner, K.-F.; Thelen, M. [Tuebingen Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Riedel, C.; Rompe, J.D. [Klinik und Poliklinik fuer Orthopaedie Johannes-Gutenberg-Univ. Mainz (Germany)

    2001-05-01

    Purpose: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. Material and Methods: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 ellbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistant pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T{sub 2}-weighted, fat-supressed TSE sequence, and a flash-2-D sequence. Also, fat-supressed, T{sub 1}-weighted SE sequences before and after administration of Gd-DTPA contrast media have been recovded. Results: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendom. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondylus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. Conclusion: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information. (orig.) [German] Zielsetzung: Evaluation der Wertigkeit der Gadolinium-DTPA-Gabe in der MR-Diagnostik der chronischen Epicondylitis humeri radialis im Vergleich zur klinischen Befunderhebung. Material und Methoden: 42 konsekutive Patienten mit einer klinisch diagnostizierten chronischen Epicondylitis humeri radialis sowie 10 Ellenbogengelenke bei 5 Probanden wurden bei 1,0 T prospektiv untersucht. Einschlusskriterium war eine persistierende Schmerzsymptomatik ueber mehr als ein halbes Jahr. Das MR-Protokoll beinhaltete neben einer STIR-Sequenz eine native T{sub 2}-gewichtete TSE-Sequenz mit Fettsupression sowie

  16. 78 FR 17108 - Approval and Promulgation of Implementation Plans; State of Washington; Revised Format for...

    Science.gov (United States)

    2013-03-20

    ...), EPA revised the procedures for IBR'ing Federally-approved SIPs, as a result of consultations between... Violations--Notices 9/8/93 2/22/95, 60 FR 9778 132 Criminal Penalty 11/13/94 10/24/95, 60 FR 54439 133 Civil............ Regulatory Actions & Civil 9/21/95 2/26/97, 62 FR 8624......... Penalties. 400-240......... Criminal...

  17. Pp scattering at SIN

    International Nuclear Information System (INIS)

    Aprile-Giboni, E.; Cantale, G.; Hausammann, R.

    1983-01-01

    Using the PM1 polarized proton beam at SIN and a polarized target, the elastic pp scattering as well as the inelastic channel pp → π + d have been studied between 400 and 600 MeV. For the elastic reaction, a sufficient number of spin dependent parameters has been measured in order to do a direct reconstruction of the scattering matrix between 38 0 /sub cm/ and 90 0 /sub cm/. 10 references, 6 figures

  18. Quantification of low fat fractions at 3T: comparison of water-fat imaging toolbox and MR spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Kořínek, Radim; Gajdošík, M.; Trattnig, S.; Krššák, M.

    2016-01-01

    Roč. 29, S1 (2016), s. 203 E-ISSN 1352-8661. [ESMRMB 2016 Congress. 29.09.2016-01.10.2016, Vienna] R&D Projects: GA ČR GA13-09086S; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : MR spectroscopy * quantification of low fat fractions Subject RIV: BH - Optics, Masers, Lasers

  19. Proton Density Fat-Fraction of Rotator Cuff Muscles Is Associated With Isometric Strength 10 Years After Rotator Cuff Repair: A Quantitative Magnetic Resonance Imaging Study of the Shoulder.

    Science.gov (United States)

    Karampinos, Dimitrios C; Holwein, Christian; Buchmann, Stefan; Baum, Thomas; Ruschke, Stefan; Gersing, Alexandra S; Sutter, Reto; Imhoff, Andreas B; Rummeny, Ernst J; Jungmann, Pia M

    2017-07-01

    Quantitative muscle fat-fraction magnetic resonance (MR) imaging techniques correlate with semiquantitative Goutallier scores with failure after rotator cuff (RC) repair. To investigate the relationship of proton density fat fraction (PDFF) of the RC muscles with semiquantitative MR scores, cartilage T2 relaxation times, and clinical isometric strength measurements in patients 10 years after unilateral RC repair. Cross-sectional study; Level of evidence, 3. Bilateral shoulder MR imaging was performed in 13 patients (11 male, 2 female; age, 72 ± 8 years) 10.9 ± 0.4 years after unilateral autologous periosteal flap augmented RC repair (total shoulders assessed, N = 26). Goutallier classification, muscle atrophy, RC tendon integrity, and cartilage defects were determined based on morphological MR sequences. A paracoronal 2D multi-slice multi-echo sequence was used for quantitative cartilage T2 mapping. A chemical shift-encoding-based water-fat separation technique (based on a 6-echo 3D spoiled gradient echo sequence) was used for quantification of the PDFF of RC muscles. Isometric shoulder abduction strength was measured clinically. Mean and SD, Pearson correlation, and partial Spearman correlation were calculated. There were 6 RC full-thickness retears in ipsilateral shoulders and 6 RC full-thickness tears in contralateral shoulders. Isometric shoulder abduction strength was not significantly different between ipsilateral and contralateral shoulders (50 ± 24 N vs 54 ± 24 N; P = .159). The mean PDFF of RC muscles was 11.7% ± 10.4% (ipsilateral, 14.2% ± 8.5%; contralateral, 9.2% ± 7.8%; P = .002). High supraspinatus PDFF correlated significantly with higher Goutallier scores ( R = 0.75, P isometric muscle strength ( R = -0.49, P = .011). This correlation remained significant after adjustment for muscle area measurements and tendon rupture ( R = -0.41, P = .048). More severe cartilage defects at the humerus were significantly associated with higher supraspinatus

  20. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  1. Karyotypes, heterochromatin, and physical mapping of 18S-26S rDNA in Cactaceae.

    Science.gov (United States)

    Las Peñas, M L; Urdampilleta, J D; Bernardello, G; Forni-Martins, E R

    2009-01-01

    Karyotype analyses in members of the four Cactaceae subfamilies were performed. Numbers and karyotype formula obtained were: Pereskioideae = Pereskiaaculeata(2n = 22; 10 m + 1 sm), Maihuenioideae = Maihuenia patagonica (2n = 22, 9 m + 2 sm; 2n = 44, 18 m + 4 sm), Opuntioideae = Cumulopuntia recurvata(2n = 44; 20 m + 2 sm), Cactoideae = Acanthocalycium spiniflorum (2n = 22; 10 m + 1 sm),Echinopsis tubiflora (2n = 22; 10 m + 1 sm), Trichocereus candicans (2n = 22, 22 m). Chromosomes were small, the average chromosome length was 2.3 mum. Diploid species and the tetraploid C. recurvata had one terminal satellite, whereas the remaining tetraploid species showed four satellited chromosomes. Karyotypes were symmetrical. No CMA(-)/DAPI(+) bands were detected, but CMA(+)/DAPI(-) bands associated with NOR were always found. Pericentromeric heterochromatin was found in C. recurvata, A. spiniflorum, and the tetraploid cytotype of M. patagonica. The locations of the 18S-26S rDNA sites in all species coincided with CMA(+)/DAPI(-) bands; the same occurred with the sizes and numbers of signals for each species. This technique was applied for the first time in metaphase chromosomes in cacti. NOR-bearing pair no.1 may be homeologous in all species examined. In Cactaceae, the 18S-26S loci seem to be highly conserved. Copyright 2009 S. Karger AG, Basel.

  2. Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0 T MR imaging

    International Nuclear Information System (INIS)

    Schuchmann, Sebastian; Weigel, Christiane; Albrecht, Lothar; Kirsch, Michael; Lemke, Arne; Lorenz, Gerd; Warzok, Rolf; Hosten, Norbert

    2007-01-01

    Introduction: Even mild hepatic steatosis in a split liver donor may cause general liver failure and death in the donor. So far, CT density measurements or percutaneous biopsy is used to determine the presence of hepatic steatosis. Magnetic resonance imaging (MRI) may be an elegant method of non-invasive and non-radiation quantification of hepatic fat content. Methods: Fast gradient echo (GRE) technique was used to discriminate between fat and water spins. Echo time (TE) was adjusted for field strength dependent in-phase and out-of-phase states at 1.0, 1.5 and 3.0 T. Continuous MR signal transition from 100% water to 100% fat was investigated using a wedge water-oil phantom, which was positioned in such a way, that no spatial resolution occurred, thereby combining water and fat in one slice. Results: Using the phantom, a significant difference for a 5% difference in fat content was demonstrated in the range from 20 to 80% fat content (p 2 = 0.93 for TE 6 ms and r 2 = 0.91 for TE 10 ms). Conclusion: The described method can be used to determine the presence of hepatic steatosis of >10% with p < 0.05

  3. Functional evaluation of hydronephrosis by diffusion-weighted MR imaging: Relationship between apparent diffusion coefficient and split glomerular filtration rate

    International Nuclear Information System (INIS)

    Toyoshima, S.; Noguchi, K.; Seto, H.; Shimizu, M.; Watanabe, N.

    2000-01-01

    To determine the relationship between apparent diffusion coefficient (ADC) values measured by diffusion-weighted MR imaging and split renal function determined by renal scintigraphy in patients with hydronephrosis. Material and Methods: Diffusion-weighted imaging on a 1.5 T MR unit and renal scintigraphy were performed in 36 patients with hydronephrosis (45 hydronephrotic kidneys, 21 non-hydronephrotic kidneys). ADC values of the individual kidneys were measured by diffusion-weighted MR imaging. Split renal function (glomerular filtration rate (GFR)) was determined by renal scintigraphy using 99m Tc-DTPA. The relationship between ADC values and split GFR was examined in 66 kidneys. The hydronephrotic kidneys were further classified into three groups (severe renal dysfunction, GFR 25 ml/min, n=28), and mean values for ADCs were calculated. Results: In hydronephrotic kidneys, there was a moderate positive correlation between ADC values and split GFR (R2=0.56). On the other hand, in non-hydronephrotic kidneys, poor correlation between ADC values and split GFR was observed (R2=0.08). The mean values for ADCs of the dysfunctioning hydronephrotic kidneys (severe renal dysfunction, 1.32x10 -3 ±0.18x10 -3 mm 2 /s; moderate renal dysfunction, 1.38x10 -3 ±0.10x10 -3 mm2/s) were significantly lower than that of the normal functioning hydronephrotic kidneys (1.63x10 -3 ±0.12±10 -3 mm 2 /s). Conclusion: These results indicated that measurement of ADC values by diffusion-weighted MR imaging has a potential value in the evaluation of the functional status of hydronephrotic kidneys

  4. Thin-shell wormholes with charge in F(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Eiroa, Ernesto F. [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina); Universidad de Buenos Aires, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina); Figueroa Aguirre, Griselda [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina)

    2016-03-15

    In this article, we construct a class of constant curvature and spherically symmetric thin-shell Lorentzian wormholes in F(R) theories of gravity and we analyze their stability under perturbations preserving the symmetry. We find that the junction conditions determine the equation of state of the matter at the throat. As a particular case, we consider configurations with mass and charge. We obtain that stable static solutions are possible for suitable values of the parameters of the model. (orig.)

  5. Thin-shell wormholes with charge in F(R) gravity

    International Nuclear Information System (INIS)

    Eiroa, Ernesto F.; Figueroa Aguirre, Griselda

    2016-01-01

    In this article, we construct a class of constant curvature and spherically symmetric thin-shell Lorentzian wormholes in F(R) theories of gravity and we analyze their stability under perturbations preserving the symmetry. We find that the junction conditions determine the equation of state of the matter at the throat. As a particular case, we consider configurations with mass and charge. We obtain that stable static solutions are possible for suitable values of the parameters of the model. (orig.)

  6. Analysis of forward and near-forward elastic-scattering amplitudes for pp and anti pp collisions

    International Nuclear Information System (INIS)

    Block, M.B.; Cahn, R.N.

    1983-04-01

    We will present the results of two recently published (1983) papers by M.M. Block and R.N. Cahn, which analyze for anti pp and pp elastic scattering the rho values (ratios of the real to the imaginary parts of the forward nuclear scattering amplitudes), the total (hadronic) cross sections sigma, and the b values, the nuclear slope parameters. The predictions of the analyses, from √ s bar > 5 GeV, is compared with the recently measured values of sigma and b at the SPS Collider. The analysis has also been redone to include new ISR data available from R211 at √ s bar = 62.5 GeV, in order to estimate odderon contributions, i.e., contributions from odd amplitudes with unconventional (non-Reggeon) energy dependence. Limits of approx. 1% are placed on these amplitudes. Our analysis has been extrapolated up to 100 TeV, to give sigma, rho and b predictions for cosmic ray and future collider energies

  7. R K Shyamasundar

    Indian Academy of Sciences (India)

    . Articles written in Resonance – Journal of Science Education. Volume 1 Issue 1 January 1996 pp 20-27 Series Article. Algorithms Introduction to Algorithms · R K Shyamasundar · More Details Fulltext PDF. Volume 1 Issue 3 March 1996 pp ...

  8. Perfusion and diffusion MR imaging in enhancing malignant cerebral tumors

    International Nuclear Information System (INIS)

    Calli, Cem; Kitis, Omer; Yunten, Nilgun; Yurtseven, Taskin; Islekel, Sertac; Akalin, Taner

    2006-01-01

    Objective: Common contrast-enhancing malignant tumors of the brain are glioblastoma multiforme (GBMs), anaplastic astrocytomas (AAs), metastases, and lymphomas, all of which have sometimes similar conventional MRI findings. Our aim was to evaluate the role of perfusion MR imaging (PWI) and diffusion-weighted imaging (DWI) in the differentiation of these contrast-enhancing malignant cerebral tumors. Materials and methods: Forty-eight patients with contrast-enhancing and histologically proven brain tumors, 14 AAs, 17 GBMs, nine metastases, and eight lymphomas, were included in the study. All patients have undergone routine MR examination where DWI and PWI were performed in the same session. DWI was performed with b values of 0, 500, and 1000 mm 2 /s. Minimum ADC values (ADC min ) of each tumor was later calculated from ADC map images. PWI was applied using dynamic susceptibility contrast technique and maximum relative cerebral blood volume (rCBV max ) was calculated from each tumor, given in ratio with contralateral normal white matter. Comparisons of ADC min and rCBV max values with the histological types of the enhancing tumors were made with a one-way analysis of variance and Bonferroni test. A P value less than 0.05 indicated a statistically significant difference. Results: The ADC min values (mean ± S.D.) in GBMs, AAs, lymphomas, and metastases were 0.79 ± 0.21 (x10 -3 mm 2 /s), 0.75 ± 0.21 (x10 -3 mm 2 /s), 0.51 ± 0.09 (x10 -3 mm 2 /s), and 0.68 ± 0.11 (x10 -3 mm 2 /s), respectively. The difference in ADC min values were statistically significant between lymphomas and GBMs (P max ratio (mean ± S.D.) in GBMs were 6.33 ± 2.03, whereas it was 3.66 ± 1.79 in AAs, 2.33 ± 0.68 in lymphomas, and 4.45 ± 1.87 in metastases. These values were statistically different between GBMs and AAs (P min and rCBV max calculations, may aid routine MR imaging in the differentiation of common cerebral contrast-enhancing malignant tumors

  9. Cardiac parasympathetic outflow during dynamic exercise in humans estimated from power spectral analysis of P-P interval variability.

    Science.gov (United States)

    Takahashi, Makoto; Nakamoto, Tomoko; Matsukawa, Kanji; Ishii, Kei; Watanabe, Tae; Sekikawa, Kiyokazu; Hamada, Hironobu

    2016-03-01

    What is the central question of this study? Should we use the high-frequency (HF) component of P-P interval as an index of cardiac parasympathetic nerve activity during moderate exercise? What is the main finding and its importance? The HF component of P-P interval variability remained even at a heart rate of 120-140 beats min(-1) and was further reduced by atropine, indicating incomplete cardiac vagal withdrawal during moderate exercise. The HF component of R-R interval is invalid as an estimate of cardiac parasympathetic outflow during moderate exercise; instead, the HF component of P-P interval variability should be used. The high-frequency (HF) component of R-R interval variability has been widely used as an indirect estimate of cardiac parasympathetic (vagal) outflow to the sino-atrial node of the heart. However, we have recently found that the variability of the R-R interval becomes much smaller during dynamic exercise than that of the P-P interval above a heart rate (HR) of ∼100 beats min(-1). We hypothesized that cardiac parasympathetic outflow during dynamic exercise with a higher intensity may be better estimated using the HF component of P-P interval variability. To test this hypothesis, the HF components of both P-P and R-R interval variability were analysed using a Wavelet transform during dynamic exercise. Twelve subjects performed ergometer exercise to increase HR from the baseline of 69 ± 3 beats min(-1) to three different levels of 100, 120 and 140 beats min(-1). We also examined the effect of atropine sulfate on the HF components in eight of the 12 subjects during exercise at an HR of 140 beats min(-1) . The HF component of P-P interval variability was significantly greater than that of R-R interval variability during exercise, especially at the HRs of 120 and 140 beats min(-1). The HF component of P-P interval variability was more reduced by atropine than that of R-R interval variability. We conclude that cardiac parasympathetic outflow to the

  10. 4D flow MR imaging of the portal venous system: a feasibility study in children

    International Nuclear Information System (INIS)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K.; Markl, Michael; Schnell, Susanne

    2017-01-01

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  11. 4D flow MR imaging of the portal venous system: a feasibility study in children

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, Keyur; Rose, Michael; Popescu, Andrada; Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); McCormick School of Engineering, Northwestern University, Department of Biomedical Engineering, Chicago, IL (United States); Schnell, Susanne [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States)

    2017-02-15

    To determine the feasibility of 4D flow MRI for visualization and quantification of the portal venous haemodynamics in children and young adults. 4D flow was performed in 28 paediatric patients (median age, 8.5 years; interquartile range, 5.2-16.5), 15 with non-operated native portal system and 13 with surgically created portal shunt. Image quality assessment for 3D flow visualization and flow pattern analyses was performed. Regional 4D flow peak velocity and net flow were compared with 2D-cine phase contrast MRI (2D-PC MR) in the post-surgical patients. Mean 3D flow visualization quality score was excellent (mean ± SD, 4.2 ± 0.9) with good inter-rater agreement (κ,0.67). Image quality in children aged >10 years was better than children ≤10 years (p < 0.05). Flow pattern was defined for portal, superior mesenteric, splenic veins and splenic artery in all patients. 4D flow and 2D-PC MR peak velocity and net flow were similar with good correlation (peak velocity: 4D flow 22.2 ± 9.1 cm/s and 2D-PC MR 25.2 ± 11.2 cm/s, p = 0.46; r = 0.92, p < 0.0001; net flow: 4D flow 9.5 ± 7.4 ml/s and 2D-PC MR 10.1 ± 7.3 ml/s, p = 0.65; r = 0.81, p = 0.0007). 4D flow MRI is feasible and holds promise for the comprehensive 3D visualization and quantification of portal venous flow dynamics in children and young adults. (orig.)

  12. Shrimp miR-10a Is Co-opted by White Spot Syndrome Virus to Increase Viral Gene Expression and Viral Replication

    Directory of Open Access Journals (Sweden)

    Jiun-Yan Huang

    2017-09-01

    Full Text Available Members of the microRNA miR-10 family are highly conserved and play many important roles in diverse biological mechanisms, including immune-related responses and cancer-related processes in certain types of cancer. In this study, we found the most highly upregulated shrimp microRNA from Penaeus vannamei during white spot syndrome virus (WSSV infection was miR-10a. After confirming the expression level of miR-10a by northern blot and quantitative RT-PCR, an in vivo experiment showed that the viral copy number was decreased in miR-10a-inhibited shrimp. We found that miR-10a targeted the 5′ untranslated region (UTR of at least three viral genes (vp26, vp28, and wssv102, and plasmids that were controlled by the 5′ UTR of these genes produced enhanced luciferase signals in transfected SF9 cells. These results suggest a previously unreported role for shrimp miR-10a and even a new type of host–virus interaction, whereby a co-opts the key cellular regulator miR-10a to globally enhance the translation of viral proteins.

  13. Shrimp miR-10a Is Co-opted by White Spot Syndrome Virus to Increase Viral Gene Expression and Viral Replication.

    Science.gov (United States)

    Huang, Jiun-Yan; Kang, Shih-Ting; Chen, I-Tung; Chang, Li-Kwan; Lin, Shih-Shun; Kou, Guang-Hsiung; Chu, Chia-Ying; Lo, Chu-Fang

    2017-01-01

    Members of the microRNA miR-10 family are highly conserved and play many important roles in diverse biological mechanisms, including immune-related responses and cancer-related processes in certain types of cancer. In this study, we found the most highly upregulated shrimp microRNA from Penaeus vannamei during white spot syndrome virus (WSSV) infection was miR-10a. After confirming the expression level of miR-10a by northern blot and quantitative RT-PCR, an in vivo experiment showed that the viral copy number was decreased in miR-10a-inhibited shrimp. We found that miR-10a targeted the 5' untranslated region (UTR) of at least three viral genes ( vp26, vp28 , and wssv102 ), and plasmids that were controlled by the 5' UTR of these genes produced enhanced luciferase signals in transfected SF9 cells. These results suggest a previously unreported role for shrimp miR-10a and even a new type of host-virus interaction, whereby a co-opts the key cellular regulator miR-10a to globally enhance the translation of viral proteins.

  14. Study of the (p,pd), (p,pt) and (p,p3He) reactions on 12C and 16O at 75MeV

    International Nuclear Information System (INIS)

    Grossiord, J.Y.; Bedjidian, M.; Guichard, A.; Gusakow, M.; Pizzi, J.R.

    1975-01-01

    The (p,pd), (p,pt) and (p,p 3 He) quasi-free scattering reactions have been studied on 12 C and 16 O targets at 75MeV. The low lying excitation levels of the residual nuclei have been observed. The appearance of T=1 states in 10 B and 14 N and of positive parity states in 13 N and 13 C can only be explained by reaction mechanisms more complex than a simple quasi-free scattering. A comparison of relative values of experimental spectroscopic factors with theoretical calculations has been made in the case of the most populated states [fr

  15. Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0 T MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schuchmann, Sebastian [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany)]. E-mail: sebastian.schuchmann@charite.de; Weigel, Christiane [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Albrecht, Lothar [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Kirsch, Michael [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Lemke, Arne [Institut fuer Radiologie, Charite, Universitaetsmedizin Berlin (Germany); Lorenz, Gerd [Institut fuer Pathologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Warzok, Rolf [Institut fuer Pathologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Hosten, Norbert [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany)

    2007-06-15

    Introduction: Even mild hepatic steatosis in a split liver donor may cause general liver failure and death in the donor. So far, CT density measurements or percutaneous biopsy is used to determine the presence of hepatic steatosis. Magnetic resonance imaging (MRI) may be an elegant method of non-invasive and non-radiation quantification of hepatic fat content. Methods: Fast gradient echo (GRE) technique was used to discriminate between fat and water spins. Echo time (TE) was adjusted for field strength dependent in-phase and out-of-phase states at 1.0, 1.5 and 3.0 T. Continuous MR signal transition from 100% water to 100% fat was investigated using a wedge water-oil phantom, which was positioned in such a way, that no spatial resolution occurred, thereby combining water and fat in one slice. Results: Using the phantom, a significant difference for a 5% difference in fat content was demonstrated in the range from 20 to 80% fat content (p < 0.05) for all tested field strengths. In 25 patients MRI data were correlated with the percentage of fat determined by histologic evaluation of a CT-guided liver biopsy. Using the linear correlation calculated from the MRI phantom data at 1.0 T, we determined the liver fat from each patient's MRI measurements. Comparison of these data with the histologic quantified fat fraction of liver tissue showed a strong correlation (r {sup 2} = 0.93 for TE 6 ms and r {sup 2} = 0.91 for TE 10 ms). Conclusion: The described method can be used to determine the presence of hepatic steatosis of >10% with p < 0.05.

  16. MR Imaging-based Estimation of Upper Motor Neuron Density in Patients with Amyotrophic Lateral Sclerosis: A Feasibility Study.

    Science.gov (United States)

    Chen, Jacqueline; Kostenko, Volodymyr; Pioro, Erik P; Trapp, Bruce D

    2018-01-23

    Purpose To determine if magnetic resonance (MR) imaging metrics can estimate primary motor cortex (PMC) motor neuron (MN) density in patients with amyotrophic lateral sclerosis (ALS). Materials and Methods Between 2012 and 2014, in situ brain MR imaging was performed in 11 patients with ALS (age range, 35-81 years; seven women and four men) soon after death (mean, 5.5 hours after death; range, 3.2-9.6 hours). The brain was removed, right PMC (RPMC) was excised, and MN density was quantified. RPMC metrics (thickness, volume, and magnetization transfer ratio) were calculated from MR images. Regression modeling was used to estimate MN density by using RPMC and global MR imaging metrics (brain and tissue volumes); clinical variables were subsequently evaluated as additional estimators. Models were tested at in vivo MR imaging by using the same imaging protocol (six patients with ALS; age range, 54-66 years; three women and three men). Results RPMC mean MN density varied over a greater than threefold range across patients and was estimated by a linear function of normalized gray matter volume (adjusted R 2 = 0.51; P = .008; <10% error in most patients). When considering only sporadic ALS, a linear function of normalized RPMC and white matter volumes estimated MN density (adjusted R 2 = 0.98; P = .01; <10% error in all patients). In vivo data analyses detected decreases in MN density over time. Conclusion PMC mean MN density varies widely in end-stage ALS possibly because of disease heterogeneity. MN density can potentially be estimated by MR imaging metrics. © RSNA, 2018 Online supplemental material is available for this article.

  17. Tumor Suppressor RARRES1 Regulates DLG2, PP2A, VCP, EB1, and Ankrd26

    Directory of Open Access Journals (Sweden)

    Ziad J. Sahab, Michael D. Hall, Lihua Zhang, Amrita K. Cheema, Stephen W. Byers

    2010-01-01

    Full Text Available Retinoic Acid Receptor Responder (RARRES1 initially identified as a novel retinoic acid receptor regulated gene in the skin is a putative tumor suppressor of unknown function. RARRES1 was knocked down in immortalized human prostatic epithelial cell line PWR-1E cells and differential protein expression was identified using differential in-gel electrophoresis (DIGE followed by matrix-assisted laser desorption ionization (MALDI mass spectrometry and western Blot analysis excluding highly abundant proteins routinely identified in almost all proteomics projects. Knock-down of RARRES1: 1- down-regulates PP2A, an enzyme involved in the negative regulation of the growth hormone-stimulated signal transduction pathways; 2- down-regulates Valosin-containing protein causing impaired autophagy; 3- up-regulates the tumor suppressor disks large 2; 4- up-regulates Ankrd26 that belongs to the POTE family of genes that are highly expressed in cancer patients with poor outcome; and 5- down-regulates EB1, a protein that is involved in spindle dynamics and chromosome alignment during mitosis.

  18. Diagnostic Accuracy of Selective 3-T MR Neurography-guided Retroperitoneal Genitofemoral Nerve Blocks for the Diagnosis of Genitofemoral Neuralgia.

    Science.gov (United States)

    Fritz, Jan; Dellon, A Lee; Williams, Eric H; Rosson, Gedge D; Belzberg, Allan J; Eckhauser, Frederick E

    2017-10-01

    Purpose To determine if 3-T magnetic resonance (MR) neurography-guided retroperitoneal genitofemoral nerve (GFN) blocks are safe and effective for the diagnosis of genitofemoral neuralgia. Materials and Methods Following institutional review board approval and informed consent, 26 subjects (16 men, 10 women; mean age, 42 years [range, 24-78 years]; mean body mass index, 28 kg/m 2 [range, 20-35 kg/m 2 ]) with intractable groin pain were included. By using a 3-T MR imaging system, intermediate-weighted turbo spin-echo pulse sequences, and MR-conditional needles, diagnostic MR neurography-guided GFN blocks were performed in the retroperitoneum. Outcome variables included technical success, procedure time, complications, and rates of positive and negative GFN blocks in association with therapeutic outcomes. For the assessment of a learning curve, Mann-Whitney test was used. P values ≤ .05 were considered to indicate a statistically significant difference. Results In 26 subjects, 30 retroperitoneal GFN blocks were performed. Twelve (40%) were performed with an anterior needle path, 12 (40%) with a lateral needle path, and six (20%) with a posterior needle path. GFN blocks were technically successful in 24 of 26 (92%) subjects, achieving appropriate scrotal anesthesia. No complications occurred. The time required for a GFN block was 40 minutes (range, 18-67 minutes). The rate of a successful GFN intervention after a positive GFN block was 88% (14 of 16). The rate of a successful intervention of an alternative target after a negative GFN block was 71% (five of seven). Conclusion Selective retroperitoneally directed MR neurography-guided GFN blocks are safe and effective with high technical success and positive effect on surgical decision making in patients with presumed genitofemoral neuralgia. © RSNA, 2017 Online supplemental material is available for this article.

  19. N-body simulations for f(R) gravity using a self-adaptive particle-mesh code

    Science.gov (United States)

    Zhao, Gong-Bo; Li, Baojiu; Koyama, Kazuya

    2011-02-01

    We perform high-resolution N-body simulations for f(R) gravity based on a self-adaptive particle-mesh code MLAPM. The chameleon mechanism that recovers general relativity on small scales is fully taken into account by self-consistently solving the nonlinear equation for the scalar field. We independently confirm the previous simulation results, including the matter power spectrum, halo mass function, and density profiles, obtained by Oyaizu [Phys. Rev. DPRVDAQ1550-7998 78, 123524 (2008)10.1103/PhysRevD.78.123524] and Schmidt [Phys. Rev. DPRVDAQ1550-7998 79, 083518 (2009)10.1103/PhysRevD.79.083518], and extend the resolution up to k˜20h/Mpc for the measurement of the matter power spectrum. Based on our simulation results, we discuss how the chameleon mechanism affects the clustering of dark matter and halos on full nonlinear scales.

  20. Differentiation of Uterine Leiomyosarcoma from Atypical Leiomyoma: Diagnostic Accuracy of Qualitative MR Imaging Features and Feasibility of Texture Analysis.

    Science.gov (United States)

    Lakhman, Yulia; Veeraraghavan, Harini; Chaim, Joshua; Feier, Diana; Goldman, Debra A; Moskowitz, Chaya S; Nougaret, Stephanie; Sosa, Ramon E; Vargas, Hebert Alberto; Soslow, Robert A; Abu-Rustum, Nadeem R; Hricak, Hedvig; Sala, Evis

    2017-07-01

    To investigate whether qualitative magnetic resonance (MR) features can distinguish leiomyosarcoma (LMS) from atypical leiomyoma (ALM) and assess the feasibility of texture analysis (TA). This retrospective study included 41 women (ALM = 22, LMS = 19) imaged with MRI prior to surgery. Two readers (R1, R2) evaluated each lesion for qualitative MR features. Associations between MR features and LMS were evaluated with Fisher's exact test. Accuracy measures were calculated for the four most significant features. TA was performed for 24 patients (ALM = 14, LMS = 10) with uniform imaging following lesion segmentation on axial T2-weighted images. Texture features were pre-selected using Wilcoxon signed-rank test with Bonferroni correction and analyzed with unsupervised clustering to separate LMS from ALM. Four qualitative MR features most strongly associated with LMS were nodular borders, haemorrhage, "T2 dark" area(s), and central unenhanced area(s) (p ≤ 0.0001 each feature/reader). The highest sensitivity [1.00 (95%CI:0.82-1.00)/0.95 (95%CI: 0.74-1.00)] and specificity [0.95 (95%CI:0.77-1.00)/1.00 (95%CI:0.85-1.00)] were achieved for R1/R2, respectively, when a lesion had ≥3 of these four features. Sixteen texture features differed significantly between LMS and ALM (p-values: feasible. • Four qualitative MR features demonstrated the strongest statistical association with LMS. • Combination of ≥3 these features could accurately differentiate LMS from ALM. • Texture analysis was a feasible semi-automated approach for lesion categorization.

  1. Reference intervals and longitudinal changes in copeptin and MR-proADM concentrations during pregnancy.

    Science.gov (United States)

    Joosen, Annemiek M C P; van der Linden, Ivon J M; Schrauwen, Lianne; Theeuwes, Alisia; de Groot, Monique J M; Ermens, Antonius A M

    2017-11-27

    Vasopressin and adrenomedullin and their stable by-products copeptin and midregional part of proadrenomedullin (MR-proADM) are promising biomarkers for the development of preeclampsia. However, clinical use is hampered by the lack of trimester-specific reference intervals. We therefore estimated reference intervals for copeptin and MR-proADM in disease-free Dutch women throughout pregnancy. Apparently healthy low risk pregnant women were recruited. Exclusion criteria included current or past history of endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, hemolysis elevated liver enzymes and low platelets, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded from analyses. Blood samples were collected at 9-13 weeks (n=98), 27-29 weeks (n=94) and 36-39 weeks (n=91) of gestation and at 4-13 weeks post-partum (PP) (n=89). Sixty-two women had complete data during pregnancy and PP. All analyses were performed on a Kryptor compact plus. Copeptin increases during pregnancy, but 97.5th percentiles remain below the non-pregnant upper reference limit (URL) provided by the manufacturer. MR-proADM concentrations increase as well during pregnancy. In trimesters 2 and 3 the 97.5th percentiles are over three times the non-pregnant URL provided by the manufacturer. Trimester- and assay-specific reference intervals for copeptin and MR-proADM should be used. In addition, consecutive measurements and the time frame between measurements should be considered as the differences seen with or in advance of preeclampsia can be expected to be relatively small compared to the reference intervals.

  2. (2S,4aR,6aR,7R,9S,10aS,10bR-7-Carboxy-2-(3-furyl-6a,10b-dimethyl-4,10-dioxoperhydrobenzo[f]isochromen-9-yl acetate

    Directory of Open Access Journals (Sweden)

    2009-03-01

    Full Text Available The asymmetric unit of the title compound, C22H26O8, contains two crystallographically independent molecules with closely comparable conformations (r.m.s. overlay = 0.54 Å for 30 non-H atoms. All six-membered rings display chair conformations, with a slight distortion for the lactone ring. The molecules are connected by O—H...O hydrogen bonds into chains along [010], with the independent molecules segregated into separate chains. The two molecules in the asymmetric unit face each other in a head-to-tail fashion, with the furan ring of one molecule turned towards the carboxylic acid terminal of the other molecule.

  3. Optimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study

    International Nuclear Information System (INIS)

    Choi, Ja Young; Hong, Sung Hwan; Kim, Na Ra; Jun, Woo Sun; Moon, Sung Gyu; Kang, Heung Sik; Lee, Joon Woo; Choi, Jung Ah

    2008-01-01

    This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities. The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging. A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography

  4. [Evaluation of cytomegalovirus quantification in blood by the R-gene real-time PCR test].

    Science.gov (United States)

    Marque-Juillet, S; Touzard, A; Monnier, S; Fernand-Laurent, C; Therby, A; Rigaudeau, S; Harzic, M

    2010-04-01

    Diagnosing the presence of cytomegalovirus (CMV) in the blood of immunodepressed patients is often done by quantitative polymerase chain reaction (Q-PCR) even though the reference method remains the antigenemia pp65 (Ag-pp65) test. To define the predictive value of the Q-PCR in the diagnosis of CMV disease and assess treatment efficacy using the CMV R-gene test. To compare the Q-PCR results and feasibility with those of the Ag-pp65 test. The Q-PCR was performed in 34 whole blood samples (frozen at -80 degrees C until use) from five patients diagnosed with CMV disease, defined as the presence of clinical signs and Ag-pp65 in the nuclei of more than two cells. After extraction, viral DNA was quantified in each sample using the Q-PCR CMV R-gene kit according to the manufacturer's instructions. Immediately after blood was drawn, the Ag-pp65 test had been performed in 32 samples using CINAkit (Argene). The 16 samples positive by the Ag-pp65 test were also positive by PCR; six samples negative by the Ag-pp65 test were positive by PCR; and the remaining 10 samples were negative by both techniques. During treatment, the two markers' kinetics were similar. The CMV R-gene test has a predictive value as good as that of the Ag-pp65 test but is fast and easier to use. A prospective study with a greater number of patients is needed to define the prediction threshold for CMV disease. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  5. 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fushimi, Yasutaka, E-mail: yfushimi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Kanda, Yumiko; Sakamoto, Ryo [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Hojo, Masato; Takahashi, Jun C.; Miyamoto, Susumu [Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan)

    2014-10-15

    Objectives: To evaluate the validity of 3D dynamic pituitary MR imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with special emphasis on demarcation of pituitary posterior lobe and stalk. Methods: Participants comprised 32 patients who underwent dynamic pituitary MR imaging due to pituitary or parasellar lesions. 3D dynamic MR with CAIPIRINHA was performed at 3 T with 20-s-interval, precontrast, 1st to 5th dynamic images. Normalized values and enhanced ratios (dynamic postcontrast image values divided by precontrast ones) were compared between 3D and 2D dynamic MR imaging for patients with visual identification of posterior lobe and stalk. Results: In 3D, stalk was identified in 29 patients and unidentified in 3, and posterior lobe was identified in 28 and unidentified in 4. In 2D, stalk was identified in 26 patients and unidentified in 6 patients, and posterior lobe was identified in 15 and unidentified in 17. Normalized values of pituitary posterior lobe and stalk were higher in 3D than 2D (P < 0.001). No significant difference in enhancement ratio was seen between 3D and 2D. Conclusions: 3D dynamic pituitary MR provided better identification and higher normalized values of pituitary posterior lobe and stalk than 2D.

  6. Differential cross sections of the pp -> pp pi sup 0 reaction from 310 to 425 MeV

    CERN Document Server

    Zlomanczuk, Yu; Brodowski, W; Calén, H; Clement, H; Dyring, J; Ekström, C; Fäldt, G; Fransson, K; Gustafsson, L; Häggström, S; Hoeistad, B; Johanson, J; Johansson, A; Johansson, T; Kilian, K; Kullander, Sven; Kupsc, A; Marciniewski, P; Morosov, B; Moertsell, A; Oelert, W; Ruber, Roger J M Y; Schuberth, U; Sundberg, P; Shwartz, B A; Stepaniak, J; Sukhanov, A; Turowiecki, A; Wagner, G J; Wilhelmi, Z; Wilkin, C; Zabierowski, J; Zernov, A

    2000-01-01

    Measurements of the differential cross sections of the pp -> pp pi sup 0 reaction at 310, 320, 340, 360, 400 and 425 MeV have been carried out at the CELSIUS storage ring in Uppsala. An attempt has been made to describe the distributions obtained in terms of the five partial waves Ss, Ps, Pp, Sd and Ds. The relative contributions from the different states depend significantly upon the energy. For instance, that of the Ss state drops from about 80% at 310 MeV to around 10% at 425 MeV.

  7. LOCUS MR: Localization of unaffected spins in MR tomography and MR spectroscopy

    International Nuclear Information System (INIS)

    Matthael, D.; Haase, A.

    1986-01-01

    Different pulse sequences have been proposed for localized in vivo MR spectroscopy. For localized MR tomography and MR spectroscopy, a method is proposed, dubbed LOCUS (LOCalization of Unaffected Spins) MR. The method uses the initial saturation of regions surrounding the region of interest (ROI) in the presence of gradients. This is followed by a conventional MR study of the unaffected ROI. In animals, human extremities, and phantoms, proton MR studies demonstrated that the method provides an optimal signal-to-noise ratio, an easily variable ROI, and ROI shim. The method can be combined with two- and three-dimensional imaging, and it allows localized measurement of MR parameters. The multinuclear capability is discussed

  8. Preoperative subtyping of meningiomas by perfusion MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University Medical Center Groningen, University of Groningen (Netherlands); Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China); Department of Radiology, University of Groningen (Netherlands); Roediger, Lars A.; Oudkerk, Matthijs [University Medical Center Groningen, University of Groningen (Netherlands); Department of Radiology, University of Groningen (Netherlands); Shen, Tianzhen [Fudan University Huashan Hospital, Department of Radiology, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University affiliated First People' s Hospital, Department of Radiology, Shanghai (China)

    2008-10-15

    This paper aims to evaluate the value of perfusion magnetic resonance (MR) imaging in the preoperative subtyping of meningiomas by analyzing the relative cerebral blood volume (rCBV) of three benign subtypes and anaplastic meningiomas separately. Thirty-seven meningiomas with peritumoral edema (15 meningothelial, ten fibrous, four angiomatous, and eight anaplastic) underwent perfusion MR imaging by using a gradient echo echo-planar sequence. The maximal rCBV (compared with contralateral normal white matter) in both tumoral parenchyma and peritumoral edema of each tumor was measured. The mean rCBVs of each two histological subtypes were compared using one-way analysis of variance and least significant difference tests. A p value less than 0.05 indicated a statistically significant difference. The mean rCBV of meningothelial, fibrous, angiomatous, and anaplastic meningiomas in tumoral parenchyma were 6.93{+-}3.75, 5.61{+-}4.03, 11.86{+-}1.93, and 5.89{+-}3.85, respectively, and in the peritumoral edema 0.87{+-}0.62, 1.38{+-}1.44, 0.87{+-}0.30, and 3.28{+-}1.39, respectively. The mean rCBV in tumoral parenchyma of angiomatous meningiomas and in the peritumoral edema of anaplastic meningiomas were statistically different (p<0.05) from the other types of meningiomas. Perfusion MR imaging can provide useful functional information on meningiomas and help in the preoperative diagnosis of some subtypes of meningiomas. (orig.)

  9. BOEKBESPREKINGS P.P. BOOK REVIEWS

    African Journals Online (AJOL)

    LOCAL ANAESTHESIA. Physiology and Pharmacology oj Local Anesthesia. By R. H. de Jong, M.D. Pp. xiv + 267. Illustrated. $12.50. Spring- field, Ill.: Charles C. Thomas. 1970. This book fills a gap in anaesthetic literature. It is written in lucid style, with ideas logically, if repetitively developed with clear figures and useful ...

  10. Autism spectrum disorder with microdeletion 10q26 by subtelomere FISH

    Directory of Open Access Journals (Sweden)

    Tonk VS

    2011-05-01

    Full Text Available Vijay S Tonk1,2, Golder N Wilson11Department of Pediatrics, Texas Tech University Health Sciences Center, Lubbock, TX, USA; 2Departments of Pathology, Obstetrics and Gynecology, Texas Tech University Health Sciences Center, Lubbock, TX, USAAbstract: An 11-year-old female with early feeding problems, mild motor delays, normal speech, subtle facial changes, social difficulties, anxiety and a diagnosis of Asperger disorder was found to have deletion of 10q26.3 by subtelomere fluorescent in situ hybridization (stF analysis. Our patient and others with 10q26 aneuploidy add this region to 11 other autism susceptibility loci qualified by converging genome linkage/association, high resolution chromosome, and mutation studies in our review. We summarize these loci and the current spectrum of terminal 10q deletion cases.Keywords: autism disorder, Asperger disorder, subtelomere FISH, microarray analysis, 10q26 deletion, gene changes in autism

  11. 10 CFR 26.133 - Cutoff levels for drugs and drug metabolites.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for drugs and drug metabolites. 26.133... § 26.133 Cutoff levels for drugs and drug metabolites. Subject to the provisions of § 26.31(d)(3)(iii), licensees and other entities may specify more stringent cutoff levels for drugs and drug metabolites than...

  12. Cosmology based on f(R) gravity admits 1 eV sterile neutrinos.

    Science.gov (United States)

    Motohashi, Hayato; Starobinsky, Alexei A; Yokoyama, Jun'ichi

    2013-03-22

    It is shown that the tension between recent neutrino oscillation experiments, favoring sterile neutrinos with masses of the order of 1 eV, and cosmological data which impose stringent constraints on neutrino masses from the free streaming suppression of density fluctuations, can be resolved in models of the present accelerated expansion of the Universe based on f(R) gravity.

  13. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  14. Conventional 20-TeV, 10-Tesla, p/sup +-/ colliders

    International Nuclear Information System (INIS)

    Diebold, R.; Ankenbrandt, C.; Collins, T.

    1982-01-01

    The performance of various 20-TeV colliders is discussed assuming 10-Tesla bending magnets. For bunched beams, the luminosity for anti pp collisions will be approximately x 10 31 cm - 2 sec - 1 where is the average number of interactions per bunch collision desired by the experimenters; for pp collisions this becomes x 10 32 cm - 2 sec - 1 . Values of up to 25 can be accommodated in a straightforward manner. Continuous beam pp collisions may yield a luminosity of 10 33 to 10 34 cm - 2 sec - 1 if the large amount of energy in the intense beams can be handled. Assuming that adequate and reliable 10-Tesla magnets can be built without unforeseen difficulties, the construction cost of such a collider, together with its new laboratory in the desert, would cost 2 to 3 billion dollars (FY-82 dollars) using present-day, conventional techniques. Although such a machine appears straightforward to build, considerable R and D will be required in order to optimize the design and bring down costs

  15. High miR156 Expression Is Required for Auxin-Induced Adventitious Root Formation via MxSPL26 Independent of PINs and ARFs in Malus xiaojinensis

    Directory of Open Access Journals (Sweden)

    Xiaozhao Xu

    2017-06-01

    Full Text Available Adventitious root formation is essential for the vegetative propagation of perennial woody plants. During the juvenile-to-adult phase change mediated by the microRNA156 (miR156, the adventitious rooting ability decreases dramatically in many species, including apple rootstocks. However, the mechanism underlying how miR156 affects adventitious root formation is unclear. In the present study, we showed that in the presence of the synthetic auxin indole-3-butyric acid (IBA, semi-lignified leafy cuttings from juvenile phase (Mx-J and rejuvenated (Mx-R Malus xiaojinensis trees exhibited significantly higher expression of miR156, PIN-FORMED1 (PIN1, PIN10, and rootless concerning crown and seminal roots-like (RTCS-like genes, thus resulting in higher adventitious rooting ability than those from adult phase (Mx-A trees. However, the expression of SQUAMOSA-PROMOTER BINDING PROTEIN-LIKE26 (SPL26 and some auxin response factor (ARF gene family members were substantially higher in Mx-A than in Mx-R cuttings. The expression of NbRTCS-like but not NbPINs and NbARFs varied with miR156 expression in tobacco (Nicotiana benthamiana plants transformed with 35S:MdMIR156a6 or 35S:MIM156 constructs. Overexpressing the miR156-resistant MxrSPL genes in tobacco confirmed the involvement of MxSPL20, MxSPL21&22, and MxSPL26 in adventitious root formation. Together, high expression of miR156 was necessary for auxin-induced adventitious root formation via MxSPL26, but independent of MxPINs and MxARFs expression in M. xiaojinensis leafy cuttings.

  16. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  17. 16 CFR 2.6 - Notification of purpose.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Notification of purpose. 2.6 Section 2.6 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE NONADJUDICATIVE... which is under investigation and the provisions of law applicable to such violation. [46 FR 26290, May...

  18. J R Vengateswaran

    Indian Academy of Sciences (India)

    More Details Fulltext PDF. Volume 4 Issue 5 May 1999 pp 88-94 General Article. Systems and Control Engineering - Control Systems-Analysis and Design · A Rama Kalyan J R Vengateswaran · More Details Fulltext PDF. Volume 4 Issue 12 December 1999 pp 76-82 General Article. Robotics - Components and Subsystems.

  19. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  20. R Divakar

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R Divakar. Articles written in Bulletin of Materials Science. Volume 36 Issue 7 December 2013 pp 1323-1329. Structural characterization of electrodeposited boron · Ashish Jain C Ghosh T R Ravindran S Anthonysamy R Divakar E Mohandas G S Gupta · More Details Abstract ...

  1. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  2. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  3. 77 FR 68851 - Mr. Brandon D. Neff, [HOME ADDRESS DELETED UNDER 10 CFR 2.390]; Order Prohibiting Involvement in...

    Science.gov (United States)

    2012-11-16

    .... Neff submitted a synthetic urine sample as specimen Y22362385, and documented in writing on the... Mr. Neff had deliberately submitted a synthetic urine sample as a specimen for a FFD drug test and... on electronic storage media. Participants may not submit paper copies of their filings unless they...

  4. Evaluation of severity in aplastic anemia by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Mi; Lim, Gye Yeon; Kim, Euy Neyng; Lee, Jae Mun; Kim, Dong Wook; Han, Chi Wha; Kim, Chun Choo [The Catholic University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To evaluate the role of bone marrow (BM) magnetic resonance (MR) imaging for assessment of the severity of aplastic anemia (AA). Eighty patients with AA, ranging in age from 16 to 44 years underwent MR imaging. Fifty four patients had clinically severe AA(SAA), while in 26 the condition was moderate(MAA). Sagittal T1-weighted images (T1WI) and short tau inversion recovery (STIR) images of lumbar vertebral BM were analysed. Bulk T1, T2 and rho values (msec) were also measured, with mixed sequences. Signal intensity (SI) on both T1WI and STIR was classified into four patterns according to the amount fatty marrow : pattern I, homogeneous fatty marrow ; 2, fatty marrow with focal cellular nodules ; 3, mixed fatty and cellular marrow ; 4, cellular marrow with focal fatty nodules. These SI patterns and bulk T1, T2 and rho values of the lumbar BM were compared with the clinical severity of AA. On both T1WI and STIR sequences, MR imaging of lumbar vertebral BM in patients with AA showed various SI patterns. Pattern 1, 2 and 3 were much frequently seen in the SAA group (48 of 54 patients on T1WI and 43 of 54 on STIR) and pattern 4 was common in the MAA group (16 of 26 patients on T1WI and 18 of 26 on STIR). The SI patterns of AA seen on both T1WI and STIR sequences closely correlated with clinical severity (x 2 test, p=0.0001). Bulk T1 value was significantly different between SAA and MAA (SAA : 382.82msec {+-} 113.91 ; MAA : 517.99msec {+-} 151.92 ; t test, p=0.0001). The SI pattern seen on MR imaging, and T1 relaxation time of lumbar spinal BM can be useful for assessing the severity of AA.

  5. Evaluation of severity in aplastic anemia by MR imaging

    International Nuclear Information System (INIS)

    Park, Jeong Mi; Lim, Gye Yeon; Kim, Euy Neyng; Lee, Jae Mun; Kim, Dong Wook; Han, Chi Wha; Kim, Chun Choo

    1999-01-01

    To evaluate the role of bone marrow (BM) magnetic resonance (MR) imaging for assessment of the severity of aplastic anemia (AA). Eighty patients with AA, ranging in age from 16 to 44 years underwent MR imaging. Fifty four patients had clinically severe AA(SAA), while in 26 the condition was moderate(MAA). Sagittal T1-weighted images (T1WI) and short tau inversion recovery (STIR) images of lumbar vertebral BM were analysed. Bulk T1, T2 and rho values (msec) were also measured, with mixed sequences. Signal intensity (SI) on both T1WI and STIR was classified into four patterns according to the amount fatty marrow : pattern I, homogeneous fatty marrow ; 2, fatty marrow with focal cellular nodules ; 3, mixed fatty and cellular marrow ; 4, cellular marrow with focal fatty nodules. These SI patterns and bulk T1, T2 and rho values of the lumbar BM were compared with the clinical severity of AA. On both T1WI and STIR sequences, MR imaging of lumbar vertebral BM in patients with AA showed various SI patterns. Pattern 1, 2 and 3 were much frequently seen in the SAA group (48 of 54 patients on T1WI and 43 of 54 on STIR) and pattern 4 was common in the MAA group (16 of 26 patients on T1WI and 18 of 26 on STIR). The SI patterns of AA seen on both T1WI and STIR sequences closely correlated with clinical severity (x 2 test, p=0.0001). Bulk T1 value was significantly different between SAA and MAA (SAA : 382.82msec ± 113.91 ; MAA : 517.99msec ± 151.92 ; t test, p=0.0001). The SI pattern seen on MR imaging, and T1 relaxation time of lumbar spinal BM can be useful for assessing the severity of AA

  6. Measurement of charged particle spectra in pp collisions and nuclear modification factor $R_\\mathrm{pPb}$ at $\\sqrt{s_{NN}}=5.02$TeV with the ATLAS detector at the LHC

    CERN Document Server

    The ATLAS collaboration

    2016-01-01

    This note presents an analysis of the inclusive charged particle spectra in pp collisions at $\\sqrt{s}=5.02$TeV that are measured with the ATLAS experiment at the LHC. The measurements are performed with pp data recorded in 2015 with an integrated luminosity of 25pb$^{-1}$. The ratio of spectra measured in the p+Pb collisions to the pp cross section scaled by the number of binary nucleon-nucleon collisions, $R_\\mathrm{pPb}$, is evaluated to facilitate a comparison of the particle production in the two colliding systems. The nuclear modification factor does not show any significant deviation from unity in the probed transverse momentum region.

  7. A general framework to test gravity using galaxy clusters - I. Modelling the dynamical mass of haloes in f(R) gravity

    Science.gov (United States)

    Mitchell, Myles A.; He, Jian-hua; Arnold, Christian; Li, Baojiu

    2018-06-01

    We propose a new framework for testing gravity using cluster observations, which aims to provide an unbiased constraint on modified gravity models from Sunyaev-Zel'dovich (SZ) and X-ray cluster counts and the cluster gas fraction, among other possible observables. Focusing on a popular f(R) model of gravity, we propose a novel procedure to recalibrate mass scaling relations from Λ cold dark matter (ΛCDM) to f(R) gravity for SZ and X-ray cluster observables. We find that the complicated modified gravity effects can be simply modelled as a dependence on a combination of the background scalar field and redshift, fR(z)/(1 + z), regardless of the f(R) model parameter. By employing a large suite of N-body simulations, we demonstrate that a theoretically derived tanh fitting formula is in excellent agreement with the dynamical mass enhancement of dark matter haloes for a large range of background field parameters and redshifts. Our framework is sufficiently flexible to allow for tests of other models and inclusion of further observables, and the one-parameter description of the dynamical mass enhancement can have important implications on the theoretical modelling of observables and on practical tests of gravity.

  8. The coordinated roles of miR-26a and miR-30c in regulating TGFβ1-induced epithelial-to-mesenchymal transition in diabetic nephropathy

    DEFF Research Database (Denmark)

    Zheng, Zongji; Guan, Meiping; Jia, Yijie

    2016-01-01

    and miR-30c targeted connective tissue growth factor (CTGF); additionally, Snail family zinc finger 1 (Snail1), a potent epithelial-to-mesenchymal transition (EMT) inducer, was targeted by miR-30c. Overexpression of miR-26a and miR-30c coordinately decreased CTGF protein levels and subsequently...

  9. Tolerance of magnetic resonance imaging in children and adolescents performed in a 1.5 Tesla MR scanner with an open design

    International Nuclear Information System (INIS)

    Adamietz, B.; Cavallaro, A.; Radkow, T.; Alibek, S.; Bautz, W.A.; Holter, W.; Staatz, G.

    2007-01-01

    Purpose: To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. Method and Materials: 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. Results: In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children 10 years old, the MR examination was not feasible and had to be repeated under sedation. Conclusion: Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner. (orig.)

  10. Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes

    Directory of Open Access Journals (Sweden)

    McVeigh Elliot R

    2009-08-01

    Full Text Available Abstract Background Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. Results The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability and antenna (signal attenuation properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. Conclusion We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.

  11. R Gnanamoorthy

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R Gnanamoorthy. Articles written in Bulletin of Materials Science. Volume 25 Issue 2 April 2002 pp 109-114 Steels and Alloys. Fretting fatigue in AISI 1015 steel · R Gnanamoorthy R Rosi Reddy · More Details Abstract Fulltext PDF. A small osillatory movement between two ...

  12. MR-guided facet joint injection therapy using an open 1.0-T MRI system: an outcome study

    International Nuclear Information System (INIS)

    Freyhardt, Patrick; Bucourt, Maximilian de; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Streitparth, Florian; Hartwig, Tony; Teichgraeber, Ulf K.M.

    2013-01-01

    To evaluate the accuracy, safety and efficacy of magnetic resonance imaging (MRI)-guided facet joint injection therapy using a 1.0-T open MRI. One hundred and sixty-six facet joint blocks in 45 patients with lower back pain were performed under MR fluoroscopic guidance using a proton-density-weighted turbo-spin-echo sequence. An in-room monitor, wireless MR-mouse for operator-controlled multiplanar navigation, a flexible surface coil and MR-compatible 20-G needle were used. Clinical outcome was evaluated by questionnaire before intervention and after 1 week, 3, 6 and 12 months using a numerical visual analogue scale (VAS). All facet joint blocks were considered technically successful with distribution of the injectant within and/or around the targeted facet joint. No major complications occurred. The final outcome analysis included 38 patients. An immediate effect was reported by 63 % of the patients. A positive mid-/long-term effect was seen in 13 patients (34 %) after 6 months and in 9 patients (24 %) after 12 months. Mean VAS was reduced from 7.1 ± 1.7 (baseline) to 3.5 ± 2.2, 4.1 ± 3.0, 3.8 ± 2.9 and 4.6 ± 2.9 at 1 week, 3, 6 and 12 months (P < 0.01). MR-guided facet joint injection therapy of the lumbosacral spine is accurate, safe and efficient in the symptomatic treatment of lower back pain. (orig.)

  13. Emergence of running dark energy from polynomial f(R) theory in Palatini formalism

    Energy Technology Data Exchange (ETDEWEB)

    Szydlowski, Marek [Jagiellonian University, Astronomical Observatory, Krakow (Poland); Jagiellonian University, Mark Kac Complex Systems Research Centre, Krakow (Poland); Stachowski, Aleksander [Jagiellonian University, Astronomical Observatory, Krakow (Poland); Borowiec, Andrzej [University of Wroclaw, Institute of Theoretical Physics, Wroclaw (Poland)

    2017-09-15

    We consider FRW cosmology in f(R)= R + γR{sup 2} + δR{sup 3} modified framework. The Palatini approach reduces its dynamics to the simple generalization of Friedmann equation. Thus we study the dynamics in two-dimensional phase space with some details. After reformulation of the model in the Einstein frame, it reduces to the FRW cosmological model with a homogeneous scalar field and vanishing kinetic energy term. This potential determines the running cosmological constant term as a function of the Ricci scalar. As a result we obtain the emergent dark energy parametrization from the covariant theory. We study also singularities of the model and demonstrate that in the Einstein frame some undesirable singularities disappear. (orig.)

  14. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  15. 76 FR 9871 - Endangered and Threatened Wildlife and Plants; Designation of Critical Habitat for Nine Bexar...

    Science.gov (United States)

    2011-02-22

    ... and Reddell 1989, p. 6; Zara 2010, pp. 9-10). Microhabitat is an important component of features... species that occur on Camp Bullis, R. exilis, R. infernalis, and Madla Cave meshweaver (Zara and Veni 2009... rocks or on the undersides of rocks or other materials (Zara and Veni 2009, pp. 497, 503). From...

  16. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  17. Alexandru Popa, Untersuchungen zu den römisch-barbarischen Kontakten Östlich der römischen Provinz Dacia Antiquitatis reihe 3 Abhnadlungen zur vor-und frühgeschichte, zur klassichen und provinzial-römischen archäologie und zur geschichte des altertum

    Directory of Open Access Journals (Sweden)

    Vasile Iarmulschi

    2016-06-01

    Full Text Available Review on book - Alexandru Popa, Untersuchungen zu den römisch-barbarischen Kontakten Östlich der römischen Provinz Dacia Antiquitatis reihe 3 Abhnadlungen zur vor-und frühgeschichte, zur klassichen und provinzial-römischen archäologie und zur geschichte des altertum

  18. Perfusion-weighted MR imaging of uterine leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Takase, Hiroyasu; Munechika, Hirotsugu [Showa Univ., Tokyo (Japan). School of Medicine

    2001-06-01

    Serial images of uterine leiomyoma in gradient-echo, echo-planar, magnetic resonance imaging were taken to draw a {delta}R2{sup *} curve after intravenous bolus injection of Gd-DTPA. The {delta}R2{sup *} integral was calculated from a {delta}R2{sup *} curve to have relative perfusion of uterine leiomyoma. We then, evaluated the amount of perfusion correlated with MR findings, size and number of leiomyoma or the clinical symptoms and established that perfusion was correlated positively with the findings of T2 weighted images and clinical symptoms but not with other MR findings or size and number of leiomyoma. In conclusion, we presumed that the clinical symptoms could be reduced by decreasing of an amount of perfusion of uterine leiomyoma in some means. However, it remained uncertain why severe clinical symptoms were associated with a high amount of perfusion in uterine leiomyomas. (author)

  19. 26 CFR 1.809-10 - Computation of equity base.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Computation of equity base. 1.809-10 Section 1... (CONTINUED) INCOME TAXES Gain and Loss from Operations § 1.809-10 Computation of equity base. (a) In general. For purposes of section 809, the equity base of a life insurance company includes the amount of any...

  20. Spherical thin shells in F(R) gravity. Construction and stability

    Energy Technology Data Exchange (ETDEWEB)

    Eiroa, Ernesto F. [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina); Universidad de Buenos Aires, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina); Figueroa Aguirre, Griselda [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina)

    2018-01-15

    We present a broad class of spherical thin shells of matter in F(R) gravity. We show that the corresponding junction conditions determine the equation of state between the energy density and the pressure/tension at the surface. We analyze the stability of the static configurations under perturbations preserving the symmetry. We apply the formalism to the construction of charged bubbles and we find that there exist stable static configurations for a suitable set of the parameters of the model. (orig.)

  1. Spherical thin shells in F(R) gravity. Construction and stability

    International Nuclear Information System (INIS)

    Eiroa, Ernesto F.; Figueroa Aguirre, Griselda

    2018-01-01

    We present a broad class of spherical thin shells of matter in F(R) gravity. We show that the corresponding junction conditions determine the equation of state between the energy density and the pressure/tension at the surface. We analyze the stability of the static configurations under perturbations preserving the symmetry. We apply the formalism to the construction of charged bubbles and we find that there exist stable static configurations for a suitable set of the parameters of the model. (orig.)

  2. FIRST PHOTOMETRIC INVESTIGATION OF THE NEWLY DISCOVERED W UMa-TYPE BINARY STAR MR Com

    Energy Technology Data Exchange (ETDEWEB)

    Qian, S.-B.; Liu, N.-P.; Liao, W.-P.; He, J.-J.; Liu, L.; Zhu, L.-Y.; Wang, J.-J.; Zhao, E.-G., E-mail: qsb@ynao.ac.cn [Yunnan Observatories, Chinese Academy of Sciences (CAS), P.O. Box 110, 650011 Kunming (China)

    2013-08-01

    By analyzing multi-color light curves of the newly discovered W UMa-type binary, MR Com, we discovered that it is a shallow-contact binary with a degree of contact factor of f = 10.0% {+-} 2.1%. Photometric solutions reveal that MR Com is a W-type system with a mass ratio of q = 3.9 where the less massive component is about 90 K hotter than the more massive one. By investigating all of the available times of minimum light, we found that the general trend of the Observed-Calculated (O - C) curve shows a downward parabolic variation while it undergoes a cyclic variation with a small amplitude of 0.0031 days and a period of 10.1 yr. The downward parabolic change corresponds to a long-term decrease in the orbital period at a rate of P-dot = -5.3 x 10{sup -7} days yr{sup -1} that may be caused by a combination of a mass transfer and an angular momentum loss (AML) via magnetic braking. Among the 16 shallow-contact systems with a decreasing orbital period, MR Com has the lowest mass ratio (e.g., 1/q = 0.26). The shallow-contact configuration, the low-mass ratio, and the long-term period decrease all suggest that systems similar to MR Com are on the AML-controlled stage of the evolutionary scheme proposed by Qian. They will oscillate around a critical mass ratio and evolve into a deep contact with a higher mass ratio. The small-amplitude cyclic change in the O - C curve was analyzed for the light-travel time effect via the presence of an extremely cool stellar companion.

  3. SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Vaitheeswaran, R; Sivaramakrishnan, KR; Kumar, Prashant; Gattamaneni, Raja; Kumar, Girish [Philips India Limited, Bangalore, Karnataka (India)

    2016-06-15

    Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

  4. Crystallization and preliminary X-ray study of a (2R,3R)-2,3-butanediol dehydrogenase from Bacillus coagulans 2-6.

    Science.gov (United States)

    Miao, Xiangzhi; Huang, Xianhui; Zhang, Guofang; Zhao, Xiufang; Zhu, Xianming; Dong, Hui

    2013-10-01

    (2R,3R)-2,3-Butanediol dehydrogenase (R,R-BDH) from Bacillus coagulans 2-6 is a zinc-dependent medium-chain alcohol dehydrogenase. Recombinant R,R-BDH with a His6 tag at the C-terminus was expressed in Escherichia coli BL21 (DE3) cells and purified by Ni2+-chelating affinity and size-exclusion chromatography. Crystals were grown by the hanging-drop vapour-diffusion method at 289 K. The crystallization condition consisted of 8%(v/v) Tacsimate pH 4.6, 18%(w/v) polyethylene glycol 3350. The crystal diffracted to 2.8 Å resolution in the orthorhombic space group P2₁2₁2₁, with unit-cell parameters a=88.35, b=128.73, c=131.03 Å.

  5. Cosmology based on f(R) gravity with O(1) eV sterile neutrino

    Energy Technology Data Exchange (ETDEWEB)

    Chudaykin, Anton S.; Gorbunov, Dmitry S. [Institute for Nuclear Research of the Russian Academy of Sciences, 60th October Anniversary prospect 7a, Moscow 117312 (Russian Federation); Starobinsky, Alexei A. [L.D. Landau Institute for Theoretical Physics of the Russian Academy of Sciences, Moscow 119334 (Russian Federation); Burenin, Rodion A., E-mail: chudy@ms2.inr.ac.ru, E-mail: gorby@ms2.inr.ac.ru, E-mail: alstar@landau.ac.ru, E-mail: rodion@hea.iki.rssi.ru [Space Research Institute of the Russian Academy of Sciences (IKI), Moscow, ul. Profsoyuznaya, 84/32, 117997 (Russian Federation)

    2015-05-01

    We address the cosmological role of an additional O(1) eV sterile neutrino in modified gravity models. We confront the present cosmological data with predictions of the FLRW cosmological model based on a variant of f(R) modified gravity proposed by one of the authors previously. This viable cosmological model which deviation from general relativity with a cosmological constant Λ decreases as R{sup −2n} for large, but not too large values of the Ricci scalar R (while no Λ is introduced by hand at small R) provides an alternative explanation of present dark energy and the accelerated expansion of the Universe (the case n=2 is considered in the paper). Various up-to-date cosmological data sets exploited include measurements of the cosmic microwave background (CMB) anisotropy, the CMB lensing potential, the baryon acoustic oscillations (BAO), the cluster mass function and the Hubble constant. We find that the CMB+BAO constraints strongly restrict the sum of neutrino masses from above. This excludes values of the model parameter λ∼ 1 for which distinctive cosmological features of the model are mostly pronounced as compared to the ΛCDM model, since then free streaming damping of perturbations due to neutrino rest masses is not sufficient to compensate their extra growth occurring in f(R) modified gravity. Thus, in the gravity sector we obtain λ>8.2 (2σ) with the account of systematic uncertainties in galaxy cluster mass function measurements and λ>9.4 (2σ) without them. At the same time in the latter case we find for the sterile neutrino mass 0.47 eV < m{sub ν, sterile} < 1 eV (2σ) assuming that the sterile neutrinos are thermalized and the active neutrinos are massless, not significantly larger than in the standard ΛCDM with the same data set: 0.45 eV < m{sub ν, sterile} < 0.92 eV (2σ). However, a possible discovery of a sterile neutrino with the mass m{sub ν, sterile} ≈ 1.5 eV motivated by various anomalies in neutrino oscillation

  6. H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Photo 01: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil (centre) with C. Melo (left) and P. Jenni Photo 02: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil (centre) with C. Melo (left) and P. Jenni. Photo 03: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil (second from right) with R. Salmeron, C. Melo, A. Dos Anjos and H. Pessoa Lima Junior. Photo 05: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil (second from left) with, from left to right C. Melo, R. Salmeron, P. Jenni. Photo 06: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science, Technology and Innovation, Brazil (left) with C. Melo. Behind, J. Ellis and J.A. Rubiol. Photo 07: At the ATLAS assembly hall H.E. Mr Ronaldo Mota Sardenberg, Minister for Science,...

  7. 41 CFR 101-26.502 - U.S. Government National Credit Card.

    Science.gov (United States)

    2010-07-01

    ... Credit Card. 101-26.502 Section 101-26.502 Public Contracts and Property Management Federal Property... SOURCES AND PROGRAM 26.5-GSA Procurement Programs § 101-26.502 U.S. Government National Credit Card. A... Standard Form 149, U.S. Government National Credit Card. [60 FR 19674, Apr. 20, 1995] ...

  8. Kallman syndrome versus idiopathic hypogonadotropic hypogonadism at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Stemmler, J.; Bergman, C.; Balzer, J.O.; Felix, R. [Free Univ. of Berlin (Germany); Heye, B.; Schopohl, J.; Danek, A. [Univ. of Munich (Germany)

    1994-04-01

    To identify morphologic differences between Kallman syndrome (KS) and idiopathic hypogonadotropic hypogonadism (IHH) and establish a role for magnetic resonance (MR) imaging in these disorders. Twenty-eight patients were compared with 10 eugonal male volunteers. Eighteen patients had KS (hypogonadotropic hypogonadism with anosmia) and 10 had IHH. All participants underwent hormone analysis, a sniff-bottle smell test, and gadolinium-enhanced MR imaging. Changes in the hypothalamic-hypophyseal region and the rhinencephalon were evaluated. MR imaging revealed intracranial morphologic changes in all patients on plain T1-weighted sections. Seventeen patients with KS demonstrated aplasia of an olfactory bulb; one olfactory sulcus was absent in six, rudimentary in four, and normal in eight. Olfactory bulbs were present in all 10 IHH patients and three showed one slightly hypoplastic bulb. Ten patients with KS and three with IHH showed an enlarged paranasal sinus system. Further MR findings were similar. MR imaging demonstrates abnormalities of the rhinencephalon present in KS patients and occasionally absent in IHH patients. 18 refs., 10 figs., 1 tab.

  9. Multiplicity correlations in the forward and backward hemispheres in the center of mass in bar pp and pp interactions at 32 GeV/c

    International Nuclear Information System (INIS)

    Bravina, L.V.; Amelin, N.S.; Bogolyubskii, M.Y.; Bumazhnov, V.A.; Vinitskii, A.A.; Ermolov, P.F.; Zhautykov, B.O.; Zabrodin, E.E.; Kiryunin, A.E.; Klochkov, M.A.; Kotova, A.I.; Kruglov, N.A.; Levitskii, M.S.; Lukina, O.Y.; Minaenko, A.A.; Moiseev, A.M.; Murzin, V.S.; Proskuryakov, A.S.; Rizatdinova, F.K.; Sarycheva, L.I.; Smirnova, L.N.; Starchenko, E.A.; Ukhanov, M.N.; Chekulaev, S.V.

    1989-01-01

    A rise in the average multiplicity of particles in one hemisphere in the c.m.s. of bar pp and pp interactions with energy (s) 1/2 =7.86 GeV is observed with increase of the number of particles in the other hemisphere. The correlation parameter reaches b=0.19±0.01 and 0.10±0.02 in inelastic bar pp and pp interactions respectively. The observed correlations are reproduced in the quark-gluon string model

  10. Diffusion-weighted MR imaging in postoperative follow-up: Reliability for detection of recurrent cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Cimsit, Nuri Cagatay [Marmara University Hospital, Department of Radiology, Istanbul (Turkey); Engin Sitesi Peker Sokak No:1 D:13, 34330 Levent, Istanbul (Turkey)], E-mail: cagataycimsit@gmail.com; Cimsit, Canan [Goztepe Education and Research Hospital, Department of Radiology, Istanbul (Turkey); Istanbul Goztepe Egitim ve Arastirma Hastanesi, Radyoloji Klinigi, Goztepe, Istanbul (Turkey)], E-mail: ccimsit@ttmail.com; Baysal, Begumhan [Goztepe Education and Research Hospital, Department of Radiology, Istanbul (Turkey); Istanbul Goztepe Egitim ve Arastirma Hastanesi, Radyoloji Klinigi, Goztepe, Istanbul (Turkey)], E-mail: begumbaysal@yahoo.com; Ruhi, Ilteris Cagatay [Goztepe Education and Research Hospital, Department of ENT, Istanbul (Turkey); Istanbul Goztepe Egitim ve Arastirma Hastanesi, KBB Klinigi, Goztepe, Istanbul (Turkey)], E-mail: cruhi@yahoo.com; Ozbilgen, Suha [Goztepe Education and Research Hospital, Department of ENT, Istanbul (Turkey); Istanbul Goztepe Egitim ve Arastirma Hastanesi, KBB Klinigi, Goztepe, Istanbul (Turkey)], E-mail: sozbilgen@yahoo.com; Aksoy, Elif Ayanoglu [Acibadem Bakirkoy Hospital, Department of ENT, Istanbul (Turkey); Acibadem Hastanesi, KBB Boeluemue, Bakirkoey, Istanbul (Turkey)], E-mail: elifayanoglu@yahoo.com

    2010-04-15

    Introduction: Cholesteatoma is a progressively growing process that destroy the neighboring bony structures and treatment is surgical removal. Follow-up is important in the postoperative period, since further surgery is necessary if recurrence is present, but not if granulation tissue is detected. This study evaluates if diffusion-weighted MR imaging alone can be a reliable alternative to CT, without use of contrast agent for follow-up of postoperative patients in detecting recurrent cholesteatoma. Materials and methods: 26 consecutive patients with mastoidectomy reporting for routine follow-up CT after mastoidectomy were included in the study, if there was loss of middle ear aeration on CT examination. MR images were evaluated for loss of aeration and signal intensity changes on diffusion-weighted sequences. Surgical results were compared with imaging findings. Results: Interpretation of MR images were parallel with the loss of aeration detected on CT for all 26 patients. Of the 26 patients examined, 14 were not evaluated as recurrent cholesteatoma and verified with surgery (NPV: 100%). Twelve patients were diagnosed as recurrent cholesteatoma and 11 were surgically diagnosed as recurrent cholesteatoma (PPV: 91.7%). Four of these 11 patients had loss of aeration size greater than the high signal intensity area on DWI, which were surgically confirmed as granulation tissue or fibrosis accompanying recurrent cholesteatoma. Conclusion: Diffusion-weighted MR for suspected recurrent cholesteatoma is a valuable tool to cut costs and prevent unnecessary second-look surgeries. It has the potential to become the MR sequence of choice to differentiate recurrent cholesteatoma from other causes of loss of aeration in patients with mastoidectomy.

  11. Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy.

    Science.gov (United States)

    Bostel, Tilman; Pfaffenberger, Asja; Delorme, Stefan; Dreher, Constantin; Echner, Gernot; Haering, Peter; Lang, Clemens; Splinter, Mona; Laun, Frederik; Müller, Marco; Jäkel, Oliver; Debus, Jürgen; Huber, Peter E; Sterzing, Florian; Nicolay, Nils H

    2018-05-01

    The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies. 20 patients with pelvic malignancies were included in this prospective feasibility analysis. Patients underwent daily MRI in treatment position prior to radiotherapy at the German Cancer Research Center. Positional inaccuracies, time and patient compliance were assessed for the application of off-line MRgRT. In 78% of applied radiation fractions, MR imaging for position verification could be performed without problems. Additionally, treatment-related side effects and reduced patient compliance were only responsible for omission of MRI in 9% of radiation fractions. The study workflow took a median time of 61 min (range 47-99 min); duration for radiotherapy alone was 13 min (range 7-26 min). Patient positioning, MR imaging and CT imaging including patient repositioning and the shuttle transfer required median times of 10 min (range 7-14 min), 26 min (range 15-60 min), 5 min (range 3-8 min) and 8 min (range 2-36 min), respectively. To assess feasibility of shuttle-based MRgRT, the reference point coordinates for the x, y and z axis were determined for the MR images and CT obtained prior to the first treatment fraction and correlated with the coordinates of the planning CT. In our dataset, the median positional difference between MR imaging and CT-based imaging based on fiducial matching between MR and CT imaging was equal to or less than 2 mm in all spatial directions. The limited space in the MR scanner influenced patient selection, as the bore of the scanner had to accommodate the immobilization device and the constructed stereotactic frame. Therefore, obese, extremely muscular or very tall patients could not be included in this trial in addition to patients for whom exposure to MRI was generally judged inappropriate. This trial demonstrated for the first time the feasibility and patient

  12. Measurements of the spin rotation parameter R in high energy elastic scattering and helicity amplitudes at Serpukhov energies

    International Nuclear Information System (INIS)

    Pierrard, J.; Bruneton, C.; Bystricky, J.; Cozzika, G.; Deregel, J.; Ducros, Y.; Gaidot, A.; Khantine-Langlois, F.; Lehar, F.; Lesquen, A. de; Merlo, J.P.; Miyashita, S.; Movchet, J.; Raoul, J.C.; Van Rossum, L.; Kanavets, V.P.

    1975-01-01

    The spin rotation parameter R in pp and π + p elastic scattering at 45GeV/c has been measured at the Serpukhov accelerator, for /t/ ranging from 0.2 to 0.5(GeV/c) 2 . The results are presented, together with previous R measurements at 3.8, 6, 16 and 40GeV/c, and are compared with the predictions of Regge pole models. The equality of the values for R in proton-proton and pion-proton scattering, within the experimental errors, is a test of factorization of the residues. An s-channel helicity amplitude analysis for pion-nucleon scattering at 40GeV/c is made using all available data. Significant results are obtained for the non flip amplitude in isoscalar exchange and for flip amplitudes on both isovector and isoscalar exchanges. The helicity flip in isoscalar exchange is non negligible. The energy dependence of this amplitude, at 6, 16 and 40GeV/c, is compared with predictions of Regge pole models [fr

  13. 26 CFR 1.162-10 - Certain employee benefits.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Certain employee benefits. 1.162-10 Section 1... employee benefits. (a) In general. Amounts paid or accrued by a taxpayer on account of injuries received by...) for the benefit of employees, their families, and dependents, at least medical or hospital care, and...

  14. Effect of seven different additives on the properties of MR fluids

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J Q; Zhang, J; Jing, Q [Department of Technical Support Engineering, Academy of Armored Force Engineering, Beijing 100072 (China)], E-mail: zhangjq63@yahoo.com.cn

    2009-02-01

    Magnetorheological (MR) fluids have been developed for application in semi-active magnetorheological fluid dampers and other magnetorheological fluid devices. In order to prepare special MR fluids to satisfy the demands of tracked vehicle, two different carrier fluids were chose to prepare MR fluids. Preparation of MR fluids, which are based on carriers such as special shock absorption fluid and 45 transformer oil, was finished. And characteristics of these samples were tested and analyzed. Results indicate, Tween-80 and Span-80 can improve sedimentary stability. Using 45 transformer oil instead of special shock absorption fluid as a carrier, the shear yield stress remains nearly invariable but the viscosity and the sedimentary stability are reduced. MR fluids with diameter of 2.73{mu}m show better sedimentary stability than that of the MR fluids with diameter of 2.3{mu}m, or 4.02{mu}m. Stearic acid obviously improves sedimentary stability and off-state viscosity, but don't perform an obvious function on shear yield stress. In magnetic field of 237KA/m, the shear yield stress of MR fluid based on special shock absorption fluid and 45 transformer oil is 18.34KPa, 14.26KPa, respectively.

  15. MR imaging of primary sclerosing cholangitis - Additional value of diffusion-weighted imaging and ADC measurement

    Energy Technology Data Exchange (ETDEWEB)

    Djokicc Kovac, Jelena [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia)], e-mail: jelenadjokic2003@yahoo.co.uk; Maksimovic, Ruzica [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Jesic, Rada [Clinic for Gastroenterohepatology, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Stanisavljevic, Dejana [Inst. for Statistics, Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Kovac, Bojan [Military Medical Academy, Belgrade (Serbia)

    2013-04-15

    Background: Primary sclerosing cholangitis (PSC) is a cholestatic liver disease with chronic inflammation and progressive destruction of biliary tree. Magnetic resonance (MR) examination with diffusion-weighted imaging (DWI) allows analysis of morphological liver parenchymal changes and non-invasive assessment of liver fibrosis. Moreover, MR cholangiopancreatography (MRCP), as a part of standard MR protocol, provides insight into bile duct irregularities. Purpose: To evaluate MR and MRCP findings in patients with primary sclerosing cholangitis and to determine the value of DWI in the assessment of liver fibrosis. Material and Methods: The following MR findings were reviewed in 38 patients: abnormalities in liver parenchyma signal intensity, changes in liver morphology, lymphadenopathy, signs of portal hypertension, and irregularities of intra- and extrahepatic bile ducts. Apparent diffusion coefficient (ADC) was calculated for six locations in the liver for b = 800 s/mm{sup 2}. Results: T2-weighted hyperintensity was seen as peripheral wedge-shaped areas in 42.1% and as periportal edema in 28.9% of patients. Increased enhancement of liver parenchyma on arterial-phase imaging was observed in six (15.8%) patients. Caudate lobe hypertrophy was present in 10 (26.3%), while spherical liver shape was noted in 7.9% of patients. Liver cirrhosis was seen in 34.2% of patients; the most common pattern was micronodular cirrhosis (61.5%). Other findings included lymphadenopathy (28.9%), signs of portal hypertension (36.7%), and bile duct irregularities (78.9%). The mean ADCs (x10{sup -3} mm{sup 2}/s) were significantly different at stage I vs. stages III and IV, and stage II vs. stage IV. No significant difference was found between stages II and III. For prediction of stage {>=}II and stage {>=}III, areas under receiver-operating characteristic curves were 0.891 and 0.887, respectively. Conclusion: MR with MRCP is a necessary diagnostic procedure for diagnosis of PSC and

  16. MR assessment of fetal pulmonary hypoplasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwashima, Shigeko; Kohno, Atsushi; Saiki, Natoru; Iimura, Fumitoshi; Kohno, Tatsuo; Hashimoto, Teisuke; Fujioka, Mutsuhisa [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-08-01

    The purpose of this study is to evaluate pulmonary hypoplasia of the fetus using MRI. The subjects consisted of 36 fetuses (18 to 40 weeks' gestation). All fetuses or mothers had major anomalies diagnosed on fetal ultrasonography. MR imaging was performed with a 1.5-T magnet and HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequence. MR images were evaluated with special attention to the intensity of the lung. A diagnosis of pulmonary hypoplasia was based on the clinical, surgical, and autopsy findings. All fetuses with normal pulmonary development showed high intensity in the lung, while all fetuses with pulmonary hypoplasia showed a low intensity in the lung, obscured pulmonary vessels and a small thorax. There was a close correlation between the lung intensity and pulmonary growth. MR assessment of lung intensity may facilitate the diagnosis of pulmonary hypoplasia, particularly after 26 weeks' gestation. Some of the normally developing lung showed a low intensity from 20 to 24 weeks of gestational age. The change to normal lung intensity may occur during this period. (author)

  17. Digitala spel : En kvalitativ studie om E-sportspelares erfarenheter från karriär och upplevd hälsa

    OpenAIRE

    Szilagyi, Ivan

    2017-01-01

    Ungdomar och unga vuxna är de främsta användarna av digitala spel och även de främsta entusiasterna av fenomenet E-sport. Spelvanor är av betydelse då studier har påvisat att det finns determinanter, både fysiologiska och psykologiska som kan påverka individens välbefinnande.Syftet med studien var att undersöka professionella E-sportspelares erfarenheter av att utöva sin sport och hur de upplever att detta påverkar hälsan. En kvalitativ metod användes och datainsamling utfördes genom intervju...

  18. MR image assessment of disc configuration and degree of anterior disc displacement in internal derangement related to age

    International Nuclear Information System (INIS)

    Igarashi, Chinami; Kobayashi, Kaoru; Imanaka, Masahiro; Yuasa, Masao; Yamamoto, Akira

    1999-01-01

    This study was designed to evaluate the configuration of the articular disc and degree of anterior disc displacement on magnetic resonance (MR) imagings in temporomandibular joints (TMJs) with internal derangement. A total of 363 joints diagnosed as having anterior disc displacement with reduction (ADD w R) and 523 joints diagnosed as having anterior disc displacement without reduction (ADD wo R) by MR imaging were examined. These joints did not show severe osseous changes on the condylar head or glenoid fossa. We assessed the configuration of the articular disc and degree of anterior disc displacement. In the ADD w R group, 82.6% of the articular discs showed biconcave configuration; enlargement of the posterior band in 4.6%, biconvex configuration in 0.5%, and others in 10.7%. Moreover 62.5% of the discs showed a slight degree of anterior disc displacement; were 27.2% moderately displaced and were 10.2% severe displaced. The prevalence of slightly displaced discs was higher in the TMJs of cases over 50 years of age than in cases under 30 years in the ADD w R group. On the other hand, in the ADD wo R group 35.9% of the articular discs showed biconcave configuration; enlargement of the posterior band in 12.6%, biconvex configuration in 25.4%, and others in 22.3%. Furthermore, 4.4% of the discs were slightly displaced; 43.9% moderately displaced and 51.6% were severely displaced. The prevalence of severely displaced and deformed discs in joints of cases over 40 years of age was high in the ADD wo R group. The prevalence of slightly displaced biconcave discs was higher in the ADD w R group. The other hand, the prevalence of severely displaced deformed discs was higher in the ADD wo R group. MR findings of internal derangement of the TMJ were found to be significantly correlated with age. (author)

  19. Explosion i rötkammare med biogas

    DEFF Research Database (Denmark)

    Hedlund, Frank Huess

    2017-01-01

    En biogasreaktor exploderade 1990 på Vejle Centrala reningsverk. Nu, 24 år senare, när biogas är populärare än någonsin, har händelsen helt försvunnit från tillgängliga, öppna källor......En biogasreaktor exploderade 1990 på Vejle Centrala reningsverk. Nu, 24 år senare, när biogas är populärare än någonsin, har händelsen helt försvunnit från tillgängliga, öppna källor...

  20. R Ramanujam

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Ramanujam. Articles written in Resonance – Journal of Science Education. Volume 6 Issue 7 July 2001 pp 97-98 Book Review. Forever Undecided: A Puzzle Guide to Gödel · R Ramanujam · More Details Fulltext PDF ...

  1. R Sarvanakumar

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Sarvanakumar. Articles written in Resonance – Journal of Science Education. Volume 12 Issue 11 November 2007 pp 77-86 Feature Article. Molecule Matters - Metal Organic Frameworks (MOFs) · R Sarvanakumar S Sankararaman · More Details Fulltext PDF ...

  2. Q ‑ Φ criticality and microstructure of charged AdS black holes in f(R) gravity

    Science.gov (United States)

    Deng, Gao-Ming; Huang, Yong-Chang

    2017-12-01

    The phase transition and critical behaviors of charged AdS black holes in f(R) gravity with a conformally invariant Maxwell (CIM) source and constant curvature are further investigated. As a highlight, this research is carried out by employing new state parameters (T,Q, Φ) and contributes to deeper understanding of the thermodynamics and phase structure of black holes. Our analyses manifest that the charged f(R)-CIM AdS black hole undergoes a first-order small-large black hole phase transition, and the critical behaviors qualitatively behave like a Van der Waals liquid-vapor system. However, differing from the case in Einstein’s gravity, phase structures of the black holes in f(R) theory exhibit an interesting dependence on gravity modification parameters. Moreover, we adopt the thermodynamic geometry to probe the black hole microscopic properties. The results show that, on the one hand, both the Ruppeiner curvature and heat capacity diverge exactly at the critical point, on the other hand, the f(R)-CIM AdS black hole possesses the property as ideal Fermi gases. Of special interest, we discover a microscopic similarity between the black holes and a Van der Waals liquid-vapor system.

  3. MR imaging - guided corticosteroid-infiltration of the sacroiliac joints: pain therapy of sacroiliitis in patients with ankylosing spondylitis; Magnetresonanzgesteuerte Kortikosteroid-Infiltration der Sakroiliakalgelenke: Schmerztherapie der Sakroiliitis bei Patienten mit Spondylitis ankylosans

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Koenig, C.W.; Clasen, S.; Claussen, C.D.; Pereira, P.L. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Guenaydin, I.; Koetter, I. [Medizinische Klinik und Poliklinik II, Rheumaambulanz, Eberhard-Karls-Univ. Tuebingen (Germany); Kastler, B. [Univ. de Franche Comte, CHU Minjoz, Besancon (France)

    2005-04-01

    Purpose: To evaluate the efficacy and specific properties of MR imaging-guided corticosteroid infiltration of the sacroiliac (SI) joints in the treatment of therapy-refractory sacroiliitis in patients with ankylosing spondylitis. Materials and Methods: In this study, 26 patients were prospectively included. Inclusion criteria were AS with therapy refractory acute sacroiliitis and inflammatory back pain {>=} 6 months. The intervention was performed using an open low-field MR-scanner. Inflammatory back pain was assessed on a visual analog scale (VAS). Success of the therapy was defined as an absolute reduction of the VAS score {<=} 5, a relative reduction of the VAS score {>=} 35% and persisting improvement {>=} 2 months. The grade of sacroiliitis was documented using high-field MR imaging. Variables were compared using McNemar test and Wilcoxon test. The mean remission time was calculated using a Kaplan-Meier analysis. A p-value < 0.05 was considered statistically significant. Results: The intervention was technically successfully performed in all patients. Following MR imaging-guided corticosteroid infiltration of the SI joints, the VAS score improved from 8 (5-10) points to 4.5 (0-8) points(-44%) in all patients (n=26), which was statistically significant (p<0.001). Of 26 patients, 22 (85%) fulfilled the predefined criteria for successful therapy. This group had a statistically significant (p<0.01) improvement of the VAS score from 8 (6-10) to 3 (0-5) (-63%). Improvement was seen after 7 (1-30) days. There was a marked reduction of the subchondral bone marrow edema (-38%). The mean remission time was 12 (4-18) months. Conclusion: MR imaging-guided corticosteroid infiltration of the SI joints proved to be an effective therapy of inflammatory back pain in patients with therapy refractory AS. With the ability of multiplanar imaging, precise localization of the bone marrow edema and the lack of ionizing radiation, interventional MR imaging currently represents the

  4. Pathological Area Detection in MR Images of Brain

    Czech Academy of Sciences Publication Activity Database

    Dvořák, P.; Kropatsch, W.G.; Bartušek, Karel

    2013-01-01

    Roč. 4, č. 1 (2013), s. 17-21 ISSN 1213-1539 R&D Projects: GA ČR GAP102/12/1104; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : Brain * Brain tumor detection * MR * Symmetry analysis Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Perfection of the individual photographic emulsion dosimeter

    International Nuclear Information System (INIS)

    Soudain, G.

    1960-01-01

    A photographic dosimeter making possible the measurement of γ radiation doses of from 10 mr up to 800 r by means of 3 emulsion bands of varying sensitivity stuck to the same support is described. The dosimeter has also a zone for marking and a test film insensitive to radiation. This requires a photometric measurement by diffuse reflection an d makes it possible to measure doses with an accuracy of 20 per cent. (author) [fr

  6. Disentangling the f(R)-duality

    Energy Technology Data Exchange (ETDEWEB)

    Broy, Benedict J.; Westphal, Alexander [Deutsches Elektronen-Synchrotron DESY, Theory Group, Hamburg, 22603 Germany (Germany); Pedro, Francisco G., E-mail: benedict.broy@desy.de, E-mail: francisco.pedro@desy.de, E-mail: alexander.westphal@desy.de [Departamento de Física Teórica and Instituto de Física Teórica UAM-CSIC, Universidad Autónoma de Madrid, Cantoblanco, Madrid, 28049 Spain (Spain)

    2015-03-01

    Motivated by UV realisations of Starobinsky-like inflation models, we study generic exponential plateau-like potentials to understand whether an exact f(R)-formulation may still be obtained when the asymptotic shift-symmetry of the potential is broken for larger field values. Potentials which break the shift symmetry with rising exponentials at large field values only allow for corresponding f(R)-descriptions with a leading order term R{sup n} with 1R{sup 2}-term survives as part of a series expansion of the function f(R) and thus cannot maintain a plateau for all field values. We further find a lean and instructive way to obtain a function f(R) describing m{sup 2}φ{sup 2}-inflation which breaks the shift symmetry with a monomial, and corresponds to effectively logarithmic corrections to an R+R{sup 2} model. These examples emphasise that higher order terms in f(R)-theory may not be neglected if they are present at all. Additionally, we relate the function f(R) corresponding to chaotic inflation to a more general Jordan frame set-up. In addition, we consider f(R)-duals of two given UV examples, both from supergravity and string theory. Finally, we outline the CMB phenomenology of these models which show effects of power suppression at low-ℓ.

  7. Disentangling the f(R)-duality

    Energy Technology Data Exchange (ETDEWEB)

    Broy, Benedict J. [Deutsches Elektronen-Synchrotron DESY, Theory Group, Hamburg, 22603 (Germany); Pedro, Francisco G. [Departamento de Física Teórica and Instituto de Física Teórica UAM-CSIC, Universidad Autónoma de Madrid, Cantoblanco, Madrid, 28049 (Spain); Westphal, Alexander [Deutsches Elektronen-Synchrotron DESY, Theory Group, Hamburg, 22603 (Germany)

    2015-03-16

    Motivated by UV realisations of Starobinsky-like inflation models, we study generic exponential plateau-like potentials to understand whether an exact f(R)-formulation may still be obtained when the asymptotic shift-symmetry of the potential is broken for larger field values. Potentials which break the shift symmetry with rising exponentials at large field values only allow for corresponding f(R)-descriptions with a leading order term R{sup n} with 1R{sup 2}-term survives as part of a series expansion of the function f(R) and thus cannot maintain a plateau for all field values. We further find a lean and instructive way to obtain a function f(R) describing m{sup 2}ϕ{sup 2}-inflation which breaks the shift symmetry with a monomial, and corresponds to effectively logarithmic corrections to an R+R{sup 2} model. These examples emphasise that higher order terms in f(R)-theory may not be neglected if they are present at all. Additionally, we relate the function f(R) corresponding to chaotic inflation to a more general Jordan frame set-up. In addition, we consider f(R)-duals of two given UV examples, both from supergravity and string theory. Finally, we outline the CMB phenomenology of these models which show effects of power suppression at low-ℓ.

  8. Comparison of MultiHance {sup trademark} and Gadovist {sup trademark} for cerebral MR perfusion imaging in healthy volunteers; Vergleich von MultiHance {sup trademark} und Gadovist {sup trademark} zur zerebralen MR-Perfusionsmessung bei gesunden Probanden

    Energy Technology Data Exchange (ETDEWEB)

    Essig, M.; LeHuu, M.; Huebener, M.; Kaick, G. van [Deutsches Krebsforschungszentrum, Abt. Radiologische Diagnostik und Therapie, Heidelberg (Germany); Lodemann, K.P. [Bracco-Byk, Gulden (Germany); Schoenberg, S.O. [Institut fuer Klinische Radiologie, Ludwig-Maximilians-Universitaet Muenchen, Grosshadern (Germany)

    2002-11-01

    To evaluate the weakly protein interacting MR contrast agent MultiHance {sup trademark} and the one-molar agent Gadovist {sup trademark} for cerebral perfusion MR imaging, a randomized intraindividual study was conducted in 12 healthy male volunteers. Perfusion-MRI was performed with single and double dose of each contrast agent on a 1.5T MR system using a gradient-echo EPI sequence. The imaging parameters, slice positioning and contrast media application were standardized. For the quantitative assessment rCBV and rCBF measurements of gray and white matter were performed. Additionally, the percentage of signal drop and the full width half maximum (FWHM) of ROI signal time curves were quantified. In a qualitative analysis the image quality of the rCBV and rCBF maps were assessed.Single dosage of the used new contrast agents was sufficient to achieve high quality perfusion maps. The susceptibility effect, described by percentage of signal loss (Gadovist {sup trademark} : 29.4% vs. MultiHance {sup trademark} : 28.3%) and the FWHM (Gadovist {sup trademark} : 6.4 s vs. Multihance {sup trademark} : 7.0 s) were not different between the agents for single dose.The one molar MR contrast agent Gadovist {sup trademark} has no advantages over MultiHance {sup trademark}, a MR contrast agent with a higher relaxivity in perfusion MRI. Both agents allow the calculation of high quality perfusion maps at a dosage of 0.1 mmol/kg bw with physiologic absolute values for regional CBV and CBF. The susceptibility effect is comparable for both agents and stronger than with conventional MR contrast media. (orig.) [German] Zur Evaluierung des gering proteinbindenden MR-Kontrastmittels MultiHance {sup trademark} und des einmolaren MR-Kontrastmittels Gadovist {sup trademark} fuer die MR-Perfusionsmessung im Gehirn wurden in einer randomisierten, intraindividuellen Vergleichsstudie 12 gesunde maennliche Probanden untersucht. Die Perfusionsmessung wurde an einem 1,5-T-MRT mit einer T2

  9. Mr Erkki Liikanen, European Commissioner for Enterprise and Information Society

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Photo 01: Visit of Mr Erkki Liikanen, at CMS experiment assembly hall at Point 5, L. to r.: : Mr Mario Campolargo, Head of Unit, Research Infrastructure, DG Information Society; Prof. Dan-Olof Riska, Director, Helsinki Institute of Physics; Prof. Ari-Pekka Hameri, HEC, University of Lausanne, Helsinki Institute of Physics; Mr Wolfgang Boch, Head of Unit, Grids for Complex Problems Solving, DG Information Society; Mr David O. Williams, Relations with the European Commission; Mr Erkki Liikanen, European Commissioner for Enterprise and Information Society; Dr Hans F. Hoffmann, Director for Technology Transfer and for Scientific Computing; Prof. Jorma Tuominiemi, Director of the CMS Programme for the Helsinki Institute of Physics; H.E. Mr Carlo Trojan, Ambassador, Head of the permanent delegation of the European Commission to the international organizations in Geneva; Prof. Erkko Autio, Helsinki University of Technology, Institute of Strategy & International Business. Photo 02: Prof. Dan-Olof Riska, Director,...

  10. 7 CFR 29.3052 - Red color (R).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Red color (R). 29.3052 Section 29.3052 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Red color (R). A brownish red. [24 FR 8771, Oct. 29, 1959. Redesignated at 47 FR 51722, Nov. 17, 1982...

  11. ICCG-10: International Conference on Crystal Growth (10th) Held in San Diego, California on August 16-21, 1992. Oral Presentation Abstracts.

    Science.gov (United States)

    1992-10-01

    D.J nt1 , A. L FrlPP. W. J. Debnam. Jir., a. A. Woodell and W. L Kw. S. A. Payne. W. F. Kruplke. L D. DeLoach. L K. Smith and J. R. Nerayanan B. Tassano...Inst. of Blo. Molec & Cell CNRS. France 9:30 Morphological Properties of CV0 AIN Films 9:30 * Growth and Dissolution Kinetics of Lysozyme Crystals R...Huntsvile. USA Physiochemie des Materltnc. France 10:00 COFFEE BREAK 10:00 Nucleation Phenomena in Crystallization of Satellite Tobacco Mosi Virus

  12. ONKALO pose experiment. Geophysical logging and imaging of drillholes ONK-PP223, ONK-PP226, ONK-PP254 and ONK-PP259...261

    International Nuclear Information System (INIS)

    Tarvainen, A.-M.

    2011-08-01

    Suomen Malmi Oy conducted geophysical drillhole logging as well as optical and acoustic imaging of shallow drillholes ONK-PP223, ONK-PP226, ONK-PP254, ONKPP259, ONK-PP260 and ONK-PP261 at ONKALO in the investigation niche ONKTKU- 3 (POSE) between December 2009 and June 2010. The survey is a part of Posiva Oy's detailed investigation program for the final disposal of spent nuclear fuel. The assignment included the field work and data processing. The report describes field operation, equipment as well as processing procedures and shows the obtained results and an analysis of their quality in the appendices. The raw and processed data are delivered digitally in WellCAD, PDF and Excel format. (orig.)

  13. R Velusamy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Velusamy. Articles written in Resonance – Journal of Science Education. Volume 12 Issue 12 December 2007 pp 12-24 General Article. Mayer-Jensen Shell Model and Magic Numbers - An Independent Nucleon Model with Spin-Orbit Coupling · R Velusamy.

  14. Measurement of the Polarization of W Bosons with Large Transverse Momenta in W+Jets Events at the LHC

    CERN Document Server

    Chatrchyan, Serguei; Sirunyan, Albert M; Tumasyan, Armen; Adam, Wolfgang; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Haensel, Stephan; Hoch, Michael; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kiesenhofer, Wolfgang; Krammer, Manfred; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Teischinger, Florian; Wagner, Philipp; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Benucci, Leonardo; De Wolf, Eddi A; Janssen, Xavier; Maes, Joris; Maes, Thomas; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Devroede, Olivier; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Michael; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Charaf, Otman; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hammad, Gregory Habib; Hreus, Tomas; Marage, Pierre Edouard; Thomas, Laurent; Vander Velde, Catherine; Vanlaer, Pascal; Adler, Volker; Cimmino, Anna; Costantini, Silvia; Grunewald, Martin; Klein, Benjamin; Lellouch, Jérémie; Marinov, Andrey; Mccartin, Joseph; Ryckbosch, Dirk; Thyssen, Filip; Tytgat, Michael; Vanelderen, Lukas; Verwilligen, Piet; Walsh, Sinead; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Caudron, Julien; Ceard, Ludivine; Cortina Gil, Eduardo; De Favereau De Jeneret, Jerome; Delaere, Christophe; Favart, Denis; Giammanco, Andrea; Grégoire, Ghislain; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Ovyn, Severine; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Schul, Nicolas; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Alves, Gilvan; De Jesus Damiao, Dilson; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Carvalho, Wagner; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Silva Do Amaral, Sheila Mara; Sznajder, Andre; Torres Da Silva De Araujo, Felipe; De Almeida Dias, Flavia; Tomei, Thiago; De Moraes Gregores, Eduardo; Lagana, Caio; Da Cunha Marinho, Franciole; Mercadante, Pedro G; Novaes, Sergio F; Padula, Sandra; Darmenov, Nikolay; Dimitrov, Lubomir; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Vankov, Ivan; Dimitrov, Anton; Hadjiiska, Roumyana; Karadzhinova, Aneliya; Kozhuharov, Venelin; Litov, Leander; Mateev, Matey; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Meng, Xiangwei; Tao, Junquan; Wang, Jian; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xiao, Hong; Xu, Ming; Zang, Jingjing; Zhang, Zhen; Ban, Yong; Guo, Shuang; Guo, Yifei; Li, Wenbo; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Zhang, Linlin; Zhu, Bo; Zou, Wei; Cabrera, Andrés; Gomez Moreno, Bernardo; Ocampo Rios, Alberto Andres; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Lelas, Karlo; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Dzelalija, Mile; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Finger, Miroslav; Finger Jr, Michael; Assran, Yasser; Khalil, Shaaban; Mahmoud, Mohammed; Hektor, Andi; Kadastik, Mario; Müntel, Mait; Raidal, Martti; Rebane, Liis; Azzolini, Virginia; Eerola, Paula; Fedi, Giacomo; Czellar, Sandor; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Kortelainen, Matti J; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Korpela, Arja; Tuuva, Tuure; Sillou, Daniel; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Gentit, François-Xavier; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Marionneau, Matthieu; Millischer, Laurent; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Verrecchia, Patrice; Baffioni, Stephanie; Beaudette, Florian; Benhabib, Lamia; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Dahms, Torsten; Dobrzynski, Ludwik; Elgammal, Sherif; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Thiebaux, Christophe; Wyslouch, Bolek; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Greder, Sebastien; Juillot, Pierre; Karim, Mehdi; Le Bihan, Anne-Catherine; Mikami, Yoshinari; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Baty, Clement; Beauceron, Stephanie; Beaupere, Nicolas; Bedjidian, Marc; Bondu, Olivier; Boudoul, Gaelle; Boumediene, Djamel; Brun, Hugues; Chasserat, Julien; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Fay, Jean; Gascon, Susan; Ille, Bernard; Kurca, Tibor; Le Grand, Thomas; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sordini, Viola; Tosi, Silvano; Tschudi, Yohann; Verdier, Patrice; Lomidze, David; Anagnostou, Georgios; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Mohr, Niklas; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Weber, Martin; Wittmer, Bruno; Ata, Metin; Bender, Walter; Dietz-Laursonn, Erik; Erdmann, Martin; Frangenheim, Jens; Hebbeker, Thomas; Hinzmann, Andreas; Hoepfner, Kerstin; Klimkovich, Tatsiana; Klingebiel, Dennis; Kreuzer, Peter; Lanske, Dankfried; Magass, Carsten; Merschmeyer, Markus; Meyer, Arnd; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Bontenackels, Michael; Davids, Martina; Duda, Markus; Flügge, Günter; Geenen, Heiko; Giffels, Manuel; Haj Ahmad, Wael; Heydhausen, Dirk; Kress, Thomas; Kuessel, Yvonne; Linn, Alexander; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Rennefeld, Jörg; Sauerland, Philip; Stahl, Achim; Thomas, Maarten; Tornier, Daiske; Zoeller, Marc Henning; Aldaya Martin, Maria; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Bethani, Agni; Borras, Kerstin; Cakir, Altan; Campbell, Alan; Castro, Elena; Dammann, Dirk; Eckerlin, Guenter; Eckstein, Doris; Flossdorf, Alexander; Flucke, Gero; Geiser, Achim; Hauk, Johannes; Jung, Hannes; Kasemann, Matthias; Katkov, Igor; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krämer, Mira; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Mankel, Rainer; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Olzem, Jan; Pitzl, Daniel; Raspereza, Alexei; Raval, Amita; Rosin, Michele; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Spiridonov, Alexander; Stein, Matthias; Tomaszewska, Justyna; Walsh, Roberval; Wissing, Christoph; Autermann, Christian; Blobel, Volker; Bobrovskyi, Sergei; Draeger, Jula; Enderle, Holger; Gebbert, Ulla; Kaschube, Kolja; Kaussen, Gordon; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Naumann-Emme, Sebastian; Nowak, Friederike; Pietsch, Niklas; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schröder, Matthias; Schum, Torben; Schwandt, Joern; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Barth, Christian; Bauer, Julia; Buege, Volker; Chwalek, Thorsten; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Feindt, Michael; Gruschke, Jasmin; Hackstein, Christoph; Hartmann, Frank; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Honc, Simon; Komaragiri, Jyothsna Rani; Kuhr, Thomas; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Peiffer, Thomas; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Ratnikova, Natalia; Renz, Manuel; Saout, Christophe; Scheurer, Armin; Schieferdecker, Philipp; Schilling, Frank-Peter; Schmanau, Mike; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Wagner-Kuhr, Jeannine; Weiler, Thomas; Zeise, Manuel; Zhukov, Valery; Ziebarth, Eva Barbara; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Ntomari, Eleni; Petrakou, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Stiliaris, Efstathios; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Triantis, Frixos A; Aranyi, Attila; Bencze, Gyorgy; Boldizsar, Laszlo; Hajdu, Csaba; Hidas, Pàl; Horvath, Dezso; Kapusi, Anita; Krajczar, Krisztian; Sikler, Ferenc; Veres, Gabor Istvan; Vesztergombi, Gyorgy; Beni, Noemi; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Veszpremi, Viktor; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Bansal, Sunil; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Gupta, Ruchi; Jindal, Monika; Kaur, Manjit; Kohli, Jatinder Mohan; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Anil; Singh, Jasbir; Singh, Supreet Pal; Ahuja, Sudha; Bhattacharya, Satyaki; Choudhary, Brajesh C; Gupta, Pooja; Jain, Sandhya; Jain, Shilpi; Kumar, Ashok; Ranjan, Kirti; Shivpuri, Ram Krishen; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kumar, Vineet; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Guchait, Monoranjan; Gurtu, Atul; Maity, Manas; Majumder, Devdatta; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Saha, Anirban; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Mondal, Naba Kumar; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Jafari, Abideh; Khakzad, Mohsen; Mohammadi, Abdollah; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Manna, Norman; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pierro, Giuseppe Antonio; Pompili, Alexis; Pugliese, Gabriella; Romano, Francesco; Roselli, Giuseppe; Selvaggi, Giovanna; Silvestris, Lucia; Trentadue, Raffaello; Tupputi, Salvatore; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Giunta, Marina; Marcellini, Stefano; Masetti, Gianni; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gianni; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Gonzi, Sandro; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Gennai, Simone; Ghezzi, Alessio; Malvezzi, Sandra; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cavallo, Nicola; De Cosa, Annapaola; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Merola, Mario; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bellan, Paolo; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; De Mattia, Marco; Dorigo, Tommaso; Dosselli, Umberto; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Mazzucato, Mirco; Meneguzzo, Anna Teresa; Nespolo, Massimo; Perrozzi, Luca; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Triossi, Andrea; Vanini, Sara; Zotto, Pierluigi; Zumerle, Gianni; Baesso, Paolo; Berzano, Umberto; Ratti, Sergio P; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Viviani, Claudio; Biasini, Maurizio; Bilei, Gian Mario; Caponeri, Benedetta; Fanò, Livio; Lariccia, Paolo; Lucaroni, Andrea; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Romeo, Francesco; Santocchia, Attilio; Taroni, Silvia; Valdata, Marisa; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Peruzzi, Marco; Segneri, Gabriele; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Di Marco, Emanuele; Diemoz, Marcella; Franci, Daniele; Grassi, Marco; Longo, Egidio; Nourbakhsh, Shervin; Organtini, Giovanni; Pandolfi, Francesco; Paramatti, Riccardo; Rahatlou, Shahram; Rovelli, Chiara; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Botta, Cristina; Cartiglia, Nicolo; Castello, Roberto; Costa, Marco; Demaria, Natale; Graziano, Alberto; Mariotti, Chiara; Marone, Matteo; Maselli, Silvia; Migliore, Ernesto; Mila, Giorgia; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Sola, Valentina; Solano, Ada; Staiano, Amedeo; Vilela Pereira, Antonio; Belforte, Stefano; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Montanino, Damiana; Penzo, Aldo; Heo, Seong Gu; Nam, Soon-Kwon; Chang, Sunghyun; Chung, Jin Hyuk; Kim, Dong Hee; Kim, Gui Nyun; Kim, Ji Eun; Kong, Dae Jung; Park, Hyangkyu; Ro, Sang-Ryul; Son, Dohhee; Son, Dong-Chul; Son, Taejin; Kim, Jaeho; Kim, Jae Yool; Song, Sanghyeon; Choi, Suyong; Hong, Byung-Sik; Jeong, Min-Soo; Jo, Mihee; Kim, Hyunchul; Kim, Ji Hyun; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Rhee, Han-Bum; Seo, Eunsung; Shin, Seungsu; Sim, Kwang Souk; Choi, Minkyoo; Kang, Seokon; Kim, Hyunyong; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Kim, Min Suk; Kwon, Eunhyang; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Martisiute, Dalia; Petrov, Pavel; Sabonis, Tomas; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-de La Cruz, Ivan; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Sánchez-Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A; Krofcheck, David; Tam, Jason; Yiu, Chun Hin; Butler, Philip H; Doesburg, Robert; Silverwood, Hamish; Ahmad, Muhammad; Ahmed, Ijaz; Asghar, Muhammad Irfan; Hoorani, Hafeez R; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Brona, Grzegorz; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Almeida, Nuno; Bargassa, Pedrame; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Musella, Pasquale; Nayak, Aruna; Ribeiro, Pedro Quinaz; Seixas, Joao; Varela, Joao; Afanasiev, Serguei; Belotelov, Ivan; Bunin, Pavel; Golutvin, Igor; Kamenev, Alexey; Karjavin, Vladimir; Kozlov, Guennady; Lanev, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Vorobyev, Andrey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Toropin, Alexander; Troitsky, Sergey; Epshteyn, Vladimir; Gavrilov, Vladimir; Kaftanov, Vitali; Kossov, Mikhail; Krokhotin, Andrey; Lychkovskaya, Natalia; Popov, Vladimir; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Kodolova, Olga; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Rusakov, Sergey V; Vinogradov, Alexey; Azhgirey, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Korablev, Andrey; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Slabospitsky, Sergey; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cepeda, Maria; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Diez Pardos, Carmen; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Vizan Garcia, Jesus Manuel; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Jorda, Clara; Lobelle Pardo, Patricia; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Piedra Gomez, Jonatan; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Sobron Sanudo, Mar; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bell, Alan James; Benedetti, Daniele; Bernet, Colin; Bialas, Wojciech; Bloch, Philippe; Bocci, Andrea; Bolognesi, Sara; Bona, Marcella; Breuker, Horst; Bunkowski, Karol; Camporesi, Tiziano; Cerminara, Gianluca; Coarasa Perez, Jose Antonio; Curé, Benoît; D'Enterria, David; De Roeck, Albert; Di Guida, Salvatore; Dupont-Sagorin, Niels; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Gaddi, Andrea; Georgiou, Georgios; Gerwig, Hubert; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Glege, Frank; Gomez-Reino Garrido, Robert; Gouzevitch, Maxime; Govoni, Pietro; Gowdy, Stephen; Guiducci, Luigi; Hansen, Magnus; Hartl, Christian; Harvey, John; Hegeman, Jeroen; Hegner, Benedikt; Hoffmann, Hans Falk; Honma, Alan; Innocente, Vincenzo; Janot, Patrick; Kaadze, Ketino; Karavakis, Edward; Lecoq, Paul; Lourenco, Carlos; Maki, Tuula; Malberti, Martina; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Maurisset, Aurelie; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Nesvold, Erik; Nguyen, Matthew; Orimoto, Toyoko; Orsini, Luciano; Perez, Emmanuelle; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Piparo, Danilo; Polese, Giovanni; Racz, Attila; Rodrigues Antunes, Joao; Rolandi, Gigi; Rommerskirchen, Tanja; Rovere, Marco; Sakulin, Hannes; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sharma, Archana; Siegrist, Patrice; Simon, Michal; Sphicas, Paraskevas; Spiropulu, Maria; Stoye, Markus; Tadel, Matevz; Tropea, Paola; Tsirou, Andromachi; Vichoudis, Paschalis; Voutilainen, Mikko; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Starodumov, Andrei; Bortignon, Pierluigi; Caminada, Lea; Chanon, Nicolas; Chen, Zhiling; Cittolin, Sergio; Dissertori, Günther; Dittmar, Michael; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Hervé, Alain; Hintz, Wieland; Lecomte, Pierre; Lustermann, Werner; Marchica, Carmelo; Martinez Ruiz del Arbol, Pablo; Meridiani, Paolo; Milenovic, Predrag; Moortgat, Filip; Nägeli, Christoph; Nef, Pascal; Nessi-Tedaldi, Francesca; Pape, Luc; Pauss, Felicitas; Punz, Thomas; Rizzi, Andrea; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Sawley, Marie-Christine; Stieger, Benjamin; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Matthias; Wehrli, Lukas; Weng, Joanna; Aguilo, Ernest; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Otiougova, Polina; Regenfus, Christian; Robmann, Peter; Schmidt, Alexander; Snoek, Hella; Chang, Yuan-Hann; Chen, Kuan-Hsin; Dutta, Suchandra; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Zong-Kai; Lu, Yun-Ju; Mekterovic, Darko; Volpe, Roberta; Wu, Jing-Han; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wang, Minzu; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Hos, Ilknur; Kangal, Evrim Ersin; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Uzun, Dilber; Vergili, Latife Nukhet; Vergili, Mehmet; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yildirim, Eda; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Demir, Durmus; Gülmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Levchuk, Leonid; Bostock, Francis; Brooke, James John; Cheng, Teh Lee; Clement, Emyr; Cussans, David; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Hansen, Maria; Hartley, Dominic; Heath, Greg P; Heath, Helen F; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J; Ward, Simon; Basso, Lorenzo; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Camanzi, Barbara; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Jackson, James; Kennedy, Bruce W; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R; Womersley, William John; Worm, Steven; Bainbridge, Robert; Ball, Gordon; Ballin, Jamie; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Davies, Gavin; Della Negra, Michel; Ferguson, William; Fulcher, Jonathan; Futyan, David; Gilbert, Andrew; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Jarvis, Martyn; Karapostoli, Georgia; Lyons, Louis; MacEvoy, Barry C; Magnan, Anne-Marie; Marrouche, Jad; Mathias, Bryn; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rogerson, Samuel; Rompotis, Nikolaos; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sharp, Peter; Sparrow, Alex; Tapper, Alexander; Tourneur, Stephane; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardle, Nicholas; Wardrope, David; Whyntie, Tom; Barrett, Matthew; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leslie, Dawn; Martin, William; Reid, Ivan; Teodorescu, Liliana; Hatakeyama, Kenichi; Bose, Tulika; Carrera Jarrin, Edgar; Fantasia, Cory; Heister, Arno; St John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Avetisyan, Aram; Bhattacharya, Saptaparna; Chou, John Paul; Cutts, David; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Landsberg, Greg; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Sinthuprasith, Tutanon; Speer, Thomas; Tsang, Ka Vang; Breedon, Richard; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Friis, Evan; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Liu, Haidong; Maruyama, Sho; Miceli, Tia; Nikolic, Milan; Pellett, Dave; Robles, Jorge; Salur, Sevil; Schwarz, Thomas; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Veelken, Christian; Andreev, Valeri; Arisaka, Katsushi; Cline, David; Cousins, Robert; Deisher, Amanda; Duris, Joseph; Erhan, Samim; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Jarvis, Chad; Plager, Charles; Rakness, Gregory; Schlein, Peter; Tucker, Jordan; Valuev, Vyacheslav; Babb, John; Chandra, Avdhesh; Clare, Robert; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Kao, Shih-Chuan; Liu, Feng; Liu, Hongliang; Long, Owen Rosser; Luthra, Arun; Nguyen, Harold; Shen, Benjamin C; Stringer, Robert; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G; Cerati, Giuseppe Benedetto; Sudano, Elizabeth; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Mangano, Boris; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pi, Haifeng; Pieri, Marco; Ranieri, Riccardo; Sani, Matteo; Sharma, Vivek; Simon, Sean; Tu, Yanjun; Vartak, Adish; Wasserbaech, Steven; Würthwein, Frank; Yagil, Avraham; Yoo, Jaehyeok; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; Vlimant, Jean-Roch; Apresyan, Artur; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Gataullin, Marat; Ma, Yousi; Mott, Alexander; Newman, Harvey B; Rogan, Christopher; Shin, Kyoungha; Timciuc, Vladlen; Traczyk, Piotr; Veverka, Jan; Wilkinson, Richard; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Jun, Soon Yung; Liu, Yueh-Feng; Paulini, Manfred; Russ, James; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Dinardo, Mauro Emanuele; Drell, Brian Robert; Edelmaier, Christopher; Ford, William T; Gaz, Alessandro; Heyburn, Bernadette; Luiggi Lopez, Eduardo; Nauenberg, Uriel; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Zang, Shi-Lei; Agostino, Lorenzo; Alexander, James; Cassel, David; Chatterjee, Avishek; Das, Souvik; Eggert, Nicholas; Gibbons, Lawrence Kent; Heltsley, Brian; Hopkins, Walter; Khukhunaishvili, Aleko; Kreis, Benjamin; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Puigh, Darren; Ryd, Anders; Salvati, Emmanuele; Shi, Xin; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Biselli, Angela; Cirino, Guy; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Apollinari, Giorgio; Atac, Muzaffer; Bakken, Jon Alan; Banerjee, Sunanda; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bloch, Ingo; Borcherding, Frederick; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Cooper, William; Eartly, David P; Elvira, Victor Daniel; Esen, Selda; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Gottschalk, Erik; Green, Dan; Gunthoti, Kranti; Gutsche, Oliver; Hanlon, Jim; Harris, Robert M; Hirschauer, James; Hooberman, Benjamin; Jensen, Hans; Johnson, Marvin; Joshi, Umesh; Khatiwada, Rakshya; Klima, Boaz; Kousouris, Konstantinos; Kunori, Shuichi; Kwan, Simon; Leonidopoulos, Christos; Limon, Peter; Lincoln, Don; Lipton, Ron; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Mason, David; McBride, Patricia; Miao, Ting; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Pordes, Ruth; Prokofyev, Oleg; Saoulidou, Niki; Sexton-Kennedy, Elizabeth; Sharma, Seema; Spalding, William J; Spiegel, Leonard; Tan, Ping; Taylor, Lucas; Tkaczyk, Slawek; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; De Gruttola, Michele; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Kim, Bockjoo; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Matchev, Konstantin; Mitselmakher, Guenakh; Muniz, Lana; Prescott, Craig; Remington, Ronald; Schmitt, Michael Houston; Scurlock, Bobby; Sellers, Paul; Skhirtladze, Nikoloz; Snowball, Matthew; Wang, Dayong; Yelton, John; Zakaria, Mohammed; Ceron, Cristobal; Gaultney, Vanessa; Kramer, Laird; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Mesa, Dalgis; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F; Prosper, Harrison; Quertenmont, Loic; Sekmen, Sezen; Veeraraghavan, Venkatesh; Baarmand, Marc M; Dorney, Brian; Guragain, Samir; Hohlmann, Marcus; Kalakhety, Himali; Ralich, Robert; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Callner, Jeremy; Cavanaugh, Richard; Dragoiu, Cosmin; Gauthier, Lucie; Gerber, Cecilia Elena; Hamdan, Saleh; Hofman, David Jonathan; Khalatyan, Samvel; Kunde, Gerd J; Lacroix, Florent; Malek, Magdalena; O'Brien, Christine; Silvestre, Catherine; Smoron, Agata; Strom, Derek; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Clarida, Warren; Duru, Firdevs; Lae, Chung Khim; McCliment, Edward; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bonato, Alessio; Eskew, Christopher; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Tran, Nhan Viet; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Grachov, Oleg; Kenny Iii, Raymond Patrick; Murray, Michael; Noonan, Daniel; Sanders, Stephen; Wood, Jeffrey Scott; Zhukova, Victoria; Barfuss, Anne-fleur; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Wan, Zongru; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Eno, Sarah Catherine; Ferencek, Dinko; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G; Kirn, Malina; Lu, Ying; Mignerey, Alice; Rossato, Kenneth; Rumerio, Paolo; Santanastasio, Francesco; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C; Twedt, Elizabeth; Alver, Burak; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Everaerts, Pieter; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Harris, Philip; Kim, Yongsun; Klute, Markus; Lee, Yen-Jie; Li, Wei; Loizides, Constantinos; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Stöckli, Fabian; Sumorok, Konstanty; Sung, Kevin; Wenger, Edward Allen; Xie, Si; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cooper, Seth; Cushman, Priscilla; Dahmes, Bryan; De Benedetti, Abraham; Dudero, Phillip Russell; Franzoni, Giovanni; Haupt, Jason; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Rekovic, Vladimir; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Cremaldi, Lucien Marcus; Godang, Romulus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Summers, Don; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R; Dominguez, Aaron; Eads, Michael; Keller, Jason; Kelly, Tony; Kravchenko, Ilya; Lazo-Flores, Jose; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R; Baur, Ulrich; Godshalk, Andrew; Iashvili, Ia; Jain, Supriya; Kharchilava, Avto; Kumar, Ashish; Shipkowski, Simon Peter; Smith, Kenneth; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Boeriu, Oana; Chasco, Matthew; Reucroft, Steve; Swain, John; Trocino, Daniele; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Kolberg, Ted; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Wayne, Mitchell; Ziegler, Jill; Bylsma, Ben; Durkin, Lloyd Stanley; Gu, Jianhui; Hill, Christopher; Killewald, Phillip; Kotov, Khristian; Ling, Ta-Yung; Rodenburg, Marissa; Williams, Grayson; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hunt, Adam; Jones, John; Laird, Edward; Lopes Pegna, David; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Acosta, Jhon Gabriel; Huang, Xing Tao; Lopez, Angel; Mendez, Hector; Oliveros, Sandra; Ramirez Vargas, Juan Eduardo; Zatserklyaniy, Andriy; Alagoz, Enver; Barnes, Virgil E; Bolla, Gino; Borrello, Laura; Bortoletto, Daniela; Everett, Adam; Garfinkel, Arthur F; Gutay, Laszlo; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Kress, Matthew; Laasanen, Alvin T; Leonardo, Nuno; Liu, Chang; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Jindal, Pratima; Parashar, Neeti; Boulahouache, Chaouki; Cuplov, Vesna; Ecklund, Karl Matthew; Geurts, Frank JM; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Flacher, Henning; Garcia-Bellido, Aran; Goldenzweig, Pablo; Gotra, Yury; Han, Jiyeon; Harel, Amnon; Miner, Daniel Carl; Orbaker, Douglas; Petrillo, Gianluca; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Malik, Sarah; Mesropian, Christina; Yan, Ming; Atramentov, Oleksiy; Barker, Anthony; Duggan, Daniel; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hits, Dmitry; Lath, Amitabh; Panwalkar, Shruti; Patel, Rishi; Richards, Alan; Rose, Keith; Schnetzer, Steve; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Eusebi, Ricardo; Gilmore, Jason; Gurrola, Alfredo; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Osipenkov, Ilya; Pakhotin, Yuriy; Pivarski, James; Safonov, Alexei; Sengupta, Sinjini; Tatarinov, Aysen; Toback, David; Weinberger, Michael; Akchurin, Nural; Bardak, Cemile; Damgov, Jordan; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Mane, Poonam; Roh, Youn; Sill, Alan; Volobouev, Igor; Wigmans, Richard; Yazgan, Efe; Appelt, Eric; Brownson, Eric; Engh, Daniel; Florez, Carlos; Gabella, William; Issah, Michael; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Cox, Bradley; Francis, Brian; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Yohay, Rachel; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Lamichhane, Pramod; Mattson, Mark; Milstène, Caroline; Sakharov, Alexandre; Anderson, Michael; Bachtis, Michail; Bellinger, James Nugent; Carlsmith, Duncan; Dasu, Sridhara; Efron, Jonathan; Flood, Kevin; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Loveless, Richard; Mohapatra, Ajit; Palmonari, Francesco; Reeder, Don; Ross, Ian; Savin, Alexander; Smith, Wesley H; Swanson, Joshua; Weinberg, Marc

    2011-01-01

    A first measurement of the polarization of W bosons with large transverse momenta in pp collisions is presented. The measurement is based on 36 inverse picobarns of data recorded at sqrt(s) = 7 TeV by the CMS detector at the LHC. The left-handed, right-handed and longitudinal polarization fractions (f_L, f_R, f_0) of W bosons with transverse momenta larger than 50 GeV are determined using decays to both electrons and muons. The muon final state yields the most precise measurement, (f_L - f_R) = 0.240 ± 0.036 (stat.) ± 0.031 (syst.) and f_0 = 0.183 ± 0.087 (stat.) ± 0.123 (syst.) for negatively charged W bosons, and (f_L - f_R) = 0.310 ± 0.036 (stat.) ± 0.017 (syst.) and f_0 = 0.171 ± 0.085 (stat.) ± 0.099 (syst.) for positively charged W bosons. This establishes, for the first time, that W bosons produced in pp collisions with large transverse momenta are predominantly left-handed, as expected in the standard model.

  15. T R Ravindran

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. T R Ravindran. Articles written in Bulletin of Materials Science. Volume 36 Issue 7 December 2013 pp 1323-1329. Structural characterization of electrodeposited boron · Ashish Jain C Ghosh T R Ravindran S Anthonysamy R Divakar E Mohandas G S Gupta · More Details ...

  16. R N Mandal

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R N Mandal. Articles written in Resonance – Journal of Science Education. Volume 18 Issue 8 August 2013 pp 732-737 General Article. The Sacred Lotus - An Incredible Wealth of Wetlands · R N Mandal R Bar · More Details Fulltext PDF ...

  17. R A Singh

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R A Singh. Articles written in Bulletin of Materials Science. Volume 28 Issue 5 August 2005 pp 423-429 Composites. Preparation and characterization of polymer composites based on charge-transfer complex of phenothiazine–iodine in polystyrene · R A Singh R K Gupta S K ...

  18. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China); Roediger, Lars A.; Oudkerk, Matthijs [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shen, Tianzhen [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China)

    2008-06-15

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16{+-}4.08 (mean{+-}SD) and 5.89{+-}3.86, respectively, in the parenchyma, and 1.05{+-}0.96 and 3.82{+-}1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16{+-}0.24 and 1.30{+-}0.32, respectively, in the parenchyma, and 0.91{+-}0.25 and 1.24{+-}0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  19. 10 CFR 26.163 - Cutoff levels for drugs and drug metabolites.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for drugs and drug metabolites. 26.163... the Department of Health and Human Services § 26.163 Cutoff levels for drugs and drug metabolites. (a... testing of specimens to determine whether they are negative for the indicated drugs and drug metabolites...

  20. f(R) global monopole revisited

    Energy Technology Data Exchange (ETDEWEB)

    Carames, Thiago R.P.; Fabris, Julio C.; Belich, H. [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil); Bezerra de Mello, E.R. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil)

    2017-07-15

    In this paper the f(R) global monopole is reexamined. We provide an exact solution for the modified field equations in the presence of a global monopole for regions outside its core, generalizing previous results. Additionally, we discuss some particular cases obtained from this solution. We consider a setup consisting of a possible Schwarzschild black hole that absorbs the topological defect, giving rise to a static black hole endowed with a monopole's charge. Besides, we demonstrate how the asymptotic behavior of the Higgs field far from the monopole's core is shaped by a class of spacetime metrics which includes the ones analyzed here. In order to assess the gravitational properties of this system, we analyze the geodesic motion of both massive and massless test particles moving in the vicinity of such configuration. For the material particles we set the requirements they have to obey in order to experience stable orbits. On the other hand, for the photons we investigate how their trajectories are affected by the gravitational field of this black hole. (orig.)

  1. 76 FR 50184 - Procurement List, Additions and Deletions

    Science.gov (United States)

    2011-08-12

    ..., Giant Cupcake, 3pc NSN: M.R. 1151--Set, Pan, Bake, Perfect Brownie Pan, 3pc NSN: M.R. 1152--Set, Pasta Cooker, Blue, Pasta Express, 7pc NSN: M.R. 1155--Glove, Oven, Flexi NSN: M.R. 1156--Device, Cutting.../Location: Laundry Services, U.S. Naval Hospital & Naval Dental Clinic Base, Farenholt Road, Agana Heights...

  2. High-resolution MR imaging of the elbow using a microscopy surface coil and a clinical 1.5 T MR machine: preliminary results

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Ueno, Teruko; Takahashi, Nobuyuki; Saida, Yukihisa; Tanaka, Toshikazu; Kujiraoka, Yuka; Shindo, Masashi; Nishiura, Yasumasa; Ochiai, Naoyuki

    2004-01-01

    To obtain high-resolution MR images of the elbow using a microscopy surface coil with a 1.5 T clinical machine and to evaluate the feasibility of its use for elbow injuries. Five asymptomatic normal volunteers and 13 patients with elbow pain were prospectively studied with MR imaging using a microscopy surface coil 47 mm in diameter. High-resolution MR images using a microscopy coil were obtained with fast spin echo (FSE) proton density-weighted sequence, gradient recalled echo (GRE) T2*-weighted sequence, and short tau inversion recovery (STIR) sequence, with a 1-2 mm slice thickness, a 50-70 mm field of view, an imaging matrix of 140-224 x 512 using zero fill interpolation, and 2-6 excitations. High-resolution MR images of normal volunteers using a microscopy coil clearly showed each structure of the medial and lateral collateral ligaments on GRE T2*-weighted images and FSE proton-density weighted images. Partial medial collateral ligament injury, a small avulsion of the medial epicondyle, and osteochondritis dissecans were well demonstrated on high-resolution MR images. High-resolution MR imaging of the elbow using a microscopy surface coil with a 1.5 T clinical machine is a promising method for accurately characterizing the normal anatomy of the elbow and depicting its lesions in detail. (orig.)

  3. The PP2AB56 phosphatase promotes the association of Cdc20 with APC/C in mitosis.

    Science.gov (United States)

    Lee, Sun Joo; Rodriguez-Bravo, Veronica; Kim, Hyunjung; Datta, Sutirtha; Foley, Emily A

    2017-05-15

    PP2A comprising B56 regulatory subunit isoforms (PP2A B56 ) is a serine/threonine phosphatase essential for mitosis. At the kinetochore, PP2A B56 both stabilizes microtubule binding and promotes silencing of the spindle assembly checkpoint (SAC) through its association with the SAC protein BubR1. Cells depleted of the B56 regulatory subunits of PP2A are delayed in activation of Cdc20-containing APC/C (APC/C Cdc20 ), which is an essential step for mitotic exit. It has been hypothesized that this delay arises from increased production of the mitotic checkpoint complex (MCC), an APC/C Cdc20 inhibitor formed at unattached kinetochores through SAC signaling. In contrast to this prediction, we show that depletion of B56 subunits does not increase the amount or stability of the MCC. Rather, delays in APC/C Cdc20 activation in B56-depleted cells correlate with impaired Cdc20 binding to APC/C. Stimulation of APC/C Cdc20 assembly does not require binding between PP2A B56 and BubR1, and thus this contribution of PP2A B56 towards mitotic exit is distinct from its functions at kinetochores. PP2A B56 associates with APC/C constitutively in a BubR1-independent manner. A mitotic phosphorylation site on Cdc20, known to be a substrate of PP2A B56 , modulates APC/C Cdc20 assembly. These results elucidate the contributions of PP2A B56 towards completion of mitosis. © 2017. Published by The Company of Biologists Ltd.

  4. 26 CFR 1.212-1 - Nontrade or nonbusiness expenses.

    Science.gov (United States)

    2010-04-01

    ..., expenses of carrying on transactions which do not constitute a trade or business of the taxpayer and are... the estate or trust is not engaged in a trade or business, except to the extent that such expenses are... in the case of a business expense. [T.D. 6500, 25 FR 11402, Nov. 26, 1960; 25 FR 14021, Dec. 12, 1960...

  5. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R [Dana Farber Cancer Institute / Brigham and Women' s Hospital, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Penzkofer, T; Schmidt, E [Brigham and Women' s Hospital, Boston, MA (United States); Pan, L; Gilson, W [Siemens Corporation, Corporate Technology, Baltimore, MD (United States); Seethamraju, R [Siemens Healthcare, Boston, MA (United States)

    2014-06-15

    ionizing radiation, with the potential to enable dosimetric guidance of catheter placement. We gratefully acknowledge support from the American Heart Association SDG 10SDG2610139, NIH 1R21CA158987-01A1, U41-RR019703, and R21 CA 167800, as well as a BWH Department of Radiation Oncology post-doctoral fellowship support. Li Pan and Wesley Gilson are employees of Siemens Corporation, Corporate Technology. Ravi Seethamraju is an employee of Siemens Healthcare.

  6. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R; Penzkofer, T; Schmidt, E; Pan, L; Gilson, W; Seethamraju, R

    2014-01-01

    ionizing radiation, with the potential to enable dosimetric guidance of catheter placement. We gratefully acknowledge support from the American Heart Association SDG 10SDG2610139, NIH 1R21CA158987-01A1, U41-RR019703, and R21 CA 167800, as well as a BWH Department of Radiation Oncology post-doctoral fellowship support. Li Pan and Wesley Gilson are employees of Siemens Corporation, Corporate Technology. Ravi Seethamraju is an employee of Siemens Healthcare

  7. MR imaging of sacral and perisacral lesions

    International Nuclear Information System (INIS)

    Wetzel, L.H.; Levine, E.; Murphey, M.D.

    1987-01-01

    This exhibit demonstrates the utility of MR imaging in evaluating sacral and perisacral lesions. Thirty-two lesions were studied using a superconducting 1.0-T MR imager. Eleven primary and 13 metastatic tumors, four congenital lesions, and four arachnoid cysts were evaluated. MR did not usually enable a more specific histologic diagnosis than other imaging techniques. However, extraosseous and proximal spinal extent of tumors was well defined without use of oral or intravenous contrast material. MR imaging is an excellent noninvasive technique for evaluating most sacral and perisacral lesions and is particularly helpful when precise tumor extent must be determined for treatment planning

  8. Usefulness of breath-hold cardiac cine MR imaging with a middle field MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kentaro; Sato, Kiyoto; Aono, Masaki; Inoshita, Kenji; Utsumi, Naoko [Kagawa Inoshita Hospital, Ohnohara (Japan)

    1999-07-01

    To assess the accuracy of contrast-enhanced, single breath-hold cine MR imaging in calculating left ventricular volume and ejection fraction, we compared MR measurements with those obtained by using cine ventriculography in 60 patients. Fast cine MR images were acquired with a middle field MR system (0.5 T). A breath-hold single slice multi-phase fast gradient-echo (Fast Card) sequence was used to obtain fast cine MR images with the following parameters; TR of 16 ms, TE of 3 ms, flip angle of 30 degree, matrix elements of 256 x 128, view per segment of 6, field of view of 350 x 260 mm and one excitation. Left ventricular end-diastolic volume and ejection fraction obtained with contrast-enhanced Fast Card correlated well with those obtained with cine ventriculography (end-diastolic volume, y=1.00x+14.0, r=0.904, p<0.001; ejection fraction, y=0.961x+2.8, r=0.936, p<0.001). Our results show that contrast enhanced breath-hold cardiac cine MR imaging on horizontal long-axis view using a middle field MR system is an accurate method for evaluating left ventricular volume and ejection fraction. (author)

  9. MR imaging of the postoperative spine

    International Nuclear Information System (INIS)

    Ross, J.S.; Modic, M.T.; Masaryk, T.T.; Bohlman, H.

    1986-01-01

    Preoperative, immediate postoperative, and delayed (2-6 months) postoperative MR studies were obtained in 20 patients who had undergone a variety of spinal surgical procedures. In addition, 50 postoperative patients without preoperative studies were also reviewed. MR studies included sagittal T1-weighted, T2-weighted, and axial T1-weighted and multiecho T2-weighted images. The evolution of signal intensity changes with time is demonstrated. Diskectomy produced no significant vertebral body changes and reduced but did not completely remove the extradural mass of herniation. Anterior fusion resulted in decreased signal on T1-weighted and increased signal on T2-weighted images in adjacent vertebral bodies, which were changes that were similar to those seen around bone grafts but distinct from the graft itself. Scar formation was better defined 2-3 months postoperatively

  10. Change of ovary before and after radiotherapy in reproductive women with cervix carcinoma in MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Min; Jeong, Yong Yeon; Kang, Heoung Keun; Lim, Hyo Soon; Yoon, Woong; Chung, Tae Woong; Seo, Jeong Jin [Chonnam National University, Kwangju (Korea, Republic of)

    2001-12-01

    To investigate changes in the ovary revealed by MR imaging before and after radiotherapy in premenopausal patients with cervical carcinoma. Thirty-three premenopausal patients with cervical carcinoma underwent radiation therapy at an average dosage of 11,279 (external: 5,352; internal: 5,927) cGy. Before and after this therapy, all underwent pelvic MR imaging using a 1.5T MR scanner (GE Medical Systems, Milwaukee, U.S.A.). The average interval of follow-up MR imaging was 7.2 months, and axial T1-weighted and axial and sagittal T2-weighted MR images were obtained. The presence, size number of follicles, and differentiation of the zonal anatomy of the ovary were determined by two radiologists, who reached a consensus. After radiation therapy, all patients ceased menstruation. For ovaries, the detection rates before and after radiation therapy were 94% (62/66) and 39% (26/66) ({rho}<0.05), respectively, and average ovary size was 2.6 X 1.9 X 2.2 cm before and 1.7 X 1.3 X 1.4 cm after therapy ({rho}<0.05). The average number of ovarian follicles before and after therapy was 5.1 and 3.1, respectively ({rho}<0.05). T2-weighted imaging, demonstrated differentiation of zonal anatomy in 74% of cases (46/62) before radiotheraphy, and 15% (4/26) after ({rho}<0.05). Our study has shown that after radiation therapy in premenopausal patients with cervical cancer, detection rates, average size, and the number of ovaries decreased, findings which are similar to those for normal postmenopausal ovary. MR imaging can reveal structural change in ovaries.

  11. 77 FR 49835 - Order Prohibiting Involvement in NRC-Licensed Activities; In the Matter of Mr. Joseph Quintanilla

    Science.gov (United States)

    2012-08-17

    ... governmental entities participating under 10 CFR 2.315(c), must be filed in accordance with the NRC E-Filing rule (72 FR 49139; August 28, 2007). The E-Filing process requires participants to submit and serve all... procedures described below. To comply with the procedural requirements of E-Filing, at least 10 days prior to...

  12. General f(R and conformal inflation from minimal supergravity plus matter

    Directory of Open Access Journals (Sweden)

    Horatiu Nastase

    2016-02-01

    Full Text Available We embed general f(R inflationary models in minimal supergravity plus matter, a single chiral superfield Φ, with or without another superfield S, via a Jordan frame Einstein+scalar description. In particular, inflationary models like a generalized Starobinsky one are analyzed and constraints on them are found. We also embed the related models of conformal inflation, also described as Jordan frame Einstein+scalar models, in particular the conformal inflation from the Higgs model, and analyze the inflationary constraints on them.

  13. D R Choudhari

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. D R Choudhari. Articles written in Resonance – Journal of Science Education. Volume 3 Issue 11 November 1998 pp 94-95 Book Review. Linear Algebra · D R Choudhari · More Details Fulltext PDF ...

  14. P R Halmos

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. P R Halmos. Articles written in Resonance – Journal of Science Education. Volume 12 Issue 2 February 2007 pp 83-95 Classics. The Thrills of Abstraction · P R Halmos · More Details Fulltext PDF ...

  15. 26 CFR 1.9005 - Statutory provisions; section 2 of the Act of September 26, 1961 (Pub. L. 87-321, 75 Stat. 683).

    Science.gov (United States)

    2010-04-01

    ... journal or other industry publication. (b) Years to which applicable. An election made under subsection (c... day for making an election under subsection (c). An election by a taxpayer under subsection (c) shall... Stat. 683; 26 U.S.C. 613 note) [T.D. 6583, 26 FR 12077, Dec. 16, 1961] ...

  16. R Sridharan

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Sridharan. Articles written in Resonance – Journal of Science Education. Volume 1 Issue 6 June 1996 pp 90-93 Book Review. Non European Roots of Mathematics - Setting the Record Straight · R Sridharan · More Details Fulltext PDF. Volume 4 Issue 8 August ...

  17. R Thangadurai

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Thangadurai. Articles written in Resonance – Journal of Science Education. Volume 17 Issue 9 September 2012 pp 855-883 General Article. S Chowla and S S Pillai - The Story of Two Peerless Indian Mathematicians · B Sury R Thangadurai · More Details ...

  18. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  19. Measurement of lipid content in gallbladder bile using in- and opposed-phase MR images and in vivo proton MR spectroscopy

    International Nuclear Information System (INIS)

    Hur, Sun Jin; Jee, Geum Nan; Yun, Eun Joo

    2002-01-01

    To evaluate the utility of signal intensity differences between in-an opposed-phase MRI and the lipid peak ratio in-vivo proton MR spectroscopy of the gallbladder as diagnostic tools for measuring the lipid content f gallbladder bile. Twenty-six normal volunteers underwent MR imaging (FMPSPGR) and in-vivo proton MR spectroscopy of the gallbladder. In all cases the results of liver function tests were normal, as were cholesterol levels, and ultrasonography of the gaubladder revealed nothing unusual. For MRI and MRS a 1.5T unit (Signa Horizon; GE Medical System, Milwaukee, U.S. A.) was used. In-phase and opposed-phase coronal-section MR images (FMPSPGR; TR=125 msec, TE=1.8, 4.2 msec) of the gallbladder were obtained, and differences in signal intensity thus determined. For proton MR spectroscopy of the gallbladder, a localized proton STEAM sequence was employed. A single voxel of 1-8 cm 3 was placed at the center of the gallbladder cavity, peak areas at 0.8-1.6 ppm (lipid), 2.0-2.4 ppm, 3.2-3.4 ppm, 3.9-4.1 ppm, and 5.2-5.4 ppm were measured by peak areas at 0.8-1.6 ppm (lipid), 2.0-2.4 ppm, 3.2-3.4 ppm, 3.9-4.1 ppm, and 5.2-5.4 ppm were measured by proton MRS and the relative peak area ratios of peak 0.8-1.6 ppm/other peaks were calculated. The degree of correlation between signal intensity differences at MRI and the relative peak area ratio of lipid in proton MRS was estimated using the p-value and Pearson's correlation coefficient. Signal intensity differences ranged from 11.3 to 43.4 % (mean, 26 ±8.9%), and the range of lipid peak area ratio at MRS was 0.10-0.97 (mean, 0.66 ±0.21). There was significant correlation between the two measured values (p=0.014, Pearson's correlation coefficient =0.478). In normal cystic bile, signal intensity differences at in-and opposed-phase MRI and relative lipid peak area ratios at MRS varied, though both methods could be used diagnostically for measuring the lipid contents of body tissue

  20. Slug-tests in PP- and PVP-holes at Olkiluoto in 2006

    International Nuclear Information System (INIS)

    Keskitalo, K.; Lindgren, S.

    2007-11-01

    As part of the program for the final disposal of the nuclear fuel waste, Posiva Oy investigates the hydrological conditions at the Olkiluoto island. The hydraulic conductivity in the shallow holes OL-PP5, OL-PP9, OL-PP36, OL-PP39, OL-PVP4A, OL-PVP4B, OL-PVP6A, OL-PVP6B and OL-PVP14 was measured in summer 2006. The length of PP-holes varies between 12 and 15 m, and the test sections (1 m) are located in the bedrock. PVP-tubes have a length up to 10 m, and the test sections (2 m) are located in the overburden. The measurements were done using the slug-test technique. In the slug-test, the hydraulic head in the borehole is abruptly changed either by pouring water into the borehole or by lowering the pressure sensor. The conductivity is interpreted based on the recovery of the water level. This report presents the field measurements and their interpretation. The interpretation has been done using the Hvorslev's method, and for reference, conductivity has also been calculated according to Thiem's equation. According to the results, hydraulic conductivity in PP-holes ranges from 10 -9 m/s to 10 -6 m/s and in PVP-tubes from 10 -8 m/s to 10 -5 m/s. The range is similar as observed in measurements of years 2002, 2004 and 2005. In general the results are consistent with the results obtained in earlier measurements. Some exceptions exist in OL-PP9, where the conductivity is lower than in the 2005 measurements, but still at the same level as in the 2002 measurements. Also, the results agree with hydraulic conductivity interpreted from the pre-pumping done in connection with the groundwater sampling. (orig.)

  1. CT and MR imaging findings of sinonasal angiomatous polyps

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Jing [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Man, Fengyuan [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China); Deng, Kai [Department of Radiology, Qingdao No. 4 People' s Hospital, Qingdao, Shandong (China); Zheng, Yuanyuan [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Hao, Dapeng, E-mail: haodp_2009@163.com [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China); Xu, Wenjian, E-mail: cjr.xuwenjian@vip.163.com [Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong (China)

    2014-03-15

    Objective: To characterize the CT and MR imaging findings of patients with sinonasal angiomatous polyps (SAPs) and evaluate their respective clinical value in the diagnosis of SAP. Methods: CT and MR imaging findings of 15 patients with pathologically proven SAP were examined. Assessed image features included location, size, margin, attenuation, and change of the bony walls of the sinonasal cavity on CT, and signal intensity and enhancement pattern on MR. Results: On CT, the SAP was mostly isoattenuated with patches of slight hyperattenuation. Most lesions caused changes in the adjacent bone, including expansile remodeling (n = 8), defect or destruction (n = 7), and hyperostosis (n = 6). All lesions examined by MR showed heterogeneous isointense signal intensity on T1-weighted images and mixed obvious hyperintense and hypointense signal intensity with linear hypointense septum internally (n = 10), and hypointense peripheral rim on T2-weighted images (n = 10). Postcontrast MR images demonstrated areas of heterogeneous and marked enhancement with an unenhanced hypointense rim and septa (n = 7). Conclusions: CT and MR imaging have respective advantages in the diagnosis of SAP. Combined application of CT and MR examinations is necessary for patients with suspected SAP.

  2. CT and MR imaging findings of sinonasal angiomatous polyps

    International Nuclear Information System (INIS)

    Zou, Jing; Man, Fengyuan; Deng, Kai; Zheng, Yuanyuan; Hao, Dapeng; Xu, Wenjian

    2014-01-01

    Objective: To characterize the CT and MR imaging findings of patients with sinonasal angiomatous polyps (SAPs) and evaluate their respective clinical value in the diagnosis of SAP. Methods: CT and MR imaging findings of 15 patients with pathologically proven SAP were examined. Assessed image features included location, size, margin, attenuation, and change of the bony walls of the sinonasal cavity on CT, and signal intensity and enhancement pattern on MR. Results: On CT, the SAP was mostly isoattenuated with patches of slight hyperattenuation. Most lesions caused changes in the adjacent bone, including expansile remodeling (n = 8), defect or destruction (n = 7), and hyperostosis (n = 6). All lesions examined by MR showed heterogeneous isointense signal intensity on T1-weighted images and mixed obvious hyperintense and hypointense signal intensity with linear hypointense septum internally (n = 10), and hypointense peripheral rim on T2-weighted images (n = 10). Postcontrast MR images demonstrated areas of heterogeneous and marked enhancement with an unenhanced hypointense rim and septa (n = 7). Conclusions: CT and MR imaging have respective advantages in the diagnosis of SAP. Combined application of CT and MR examinations is necessary for patients with suspected SAP

  3. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    International Nuclear Information System (INIS)

    Zhang, Hao; Roediger, Lars A.; Oudkerk, Matthijs; Shen, Tianzhen; Miao, Jingtao

    2008-01-01

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16±4.08 (mean±SD) and 5.89±3.86, respectively, in the parenchyma, and 1.05±0.96 and 3.82±1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16±0.24 and 1.30±0.32, respectively, in the parenchyma, and 0.91±0.25 and 1.24±0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  4. MR imaging and histopathology of cartilage tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mizutani, Hirokazu; Ohba, Satoru; Ohtsuka, Takanobu; Matui, Norio; Nakamura, Takaaki (Nagoya City Univ. (Japan). Faculty of Medicine)

    1994-05-01

    The MR imaging-pathologic correlation of cartilaginous bone tumors and the value of intravenously administered Gd-DTPA enhanced MR imaging was studied. The MR studies were retrospectively reviewed. Thirty-seven cases were examined with 0.5 T and 1.0 T scanner and all cases were pathologically proved. We discussed the following MR findings: signal intensities of tumors, Gd-DTPA features, morphological findings, and associated findings. Hyaline cartilage tumors showed low signal intensity on T[sub 1]-weighted images and very high signal intensity on T[sub 2]-weighted images. Lobulated marginal enhancements were recognized in chondrosarcomas. This may be an important finding to suspect chondrosarcoma. (author).

  5. Vinod R Kanetkar

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. Vinod R Kanetkar. Articles written in Resonance – Journal of Science Education. Volume 15 Issue 9 September 2010 pp 794-803 General Article. Colour: History and Advancements · Vinod R Kanetkar · More Details Fulltext PDF ...

  6. P R Mirkute

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. P R Mirkute. Articles written in Sadhana. Volume 28 Issue 6 December 2003 pp 1019-1026. A third-order active-R filter with feedforward input signal · G N Shinde P B Patil P R Mirkute · More Details Abstract Fulltext PDF. A realization of voltage-mode transfer functions with feedforward input signal ...

  7. R S Khadayate

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R S Khadayate. Articles written in Bulletin of Materials Science. Volume 30 Issue 2 April 2007 pp 129-133 Thin Films. Ethanol vapour sensing properties of screen printed WO3 thick films · R S Khadayate R B Waghulde M G Wankhede J V Sali P P Patil · More Details Abstract ...

  8. MR imaging in hemophilic arthropathy

    International Nuclear Information System (INIS)

    Baunin, C.; Railhac, J.J.; Younes, I.; Gaubert, J.; DuBoullay, C.; Dirat, G.; Robert, A.

    1990-01-01

    This paper reports on twenty children with hemophilia examined to determine if MR imaging could be used to assess hemophilic arthropathy. Twenty-eight joints were imaged (17 knees, 10 ankles, 1 elbow) with plain radiography, US, CT, and MR imaging. The results were compared with the surgical view and histologic study of the articular components when synovectomy was done. These results show the usefulness of MR imaging: fluid collections in the joint space were evaluated, and it was possible to distinguish blood from inflammatory fluid. Synovial hypertrophy was appreciated, and findings correlated well with histologic study. Anomalies of articular cartilage, joint-space narrowing, and bone lesions were demonstrated early, when plain radiography findings were still normal

  9. Constraining models of f(R) gravity with Planck and WiggleZ power spectrum data

    Science.gov (United States)

    Dossett, Jason; Hu, Bin; Parkinson, David

    2014-03-01

    In order to explain cosmic acceleration without invoking ``dark'' physics, we consider f(R) modified gravity models, which replace the standard Einstein-Hilbert action in General Relativity with a higher derivative theory. We use data from the WiggleZ Dark Energy survey to probe the formation of structure on large scales which can place tight constraints on these models. We combine the large-scale structure data with measurements of the cosmic microwave background from the Planck surveyor. After parameterizing the modification of the action using the Compton wavelength parameter B0, we constrain this parameter using ISiTGR, assuming an initial non-informative log prior probability distribution of this cross-over scale. We find that the addition of the WiggleZ power spectrum provides the tightest constraints to date on B0 by an order of magnitude, giving log10(B0) explanation.

  10. Radiochemical analysis of the body of the late Mr. Kuboyama

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, K; Ikedo, N; Kimura, K; Kawanishi, H; Kimura, M

    1956-01-01

    Analyses were carried out of various organs of Mr. Kuboyama 200 days after he had exposed himself to radiation of the atomic bomb explosion on Bikini Atoll, March, 1954. By ion-exchange chromatography, the presence of the following nuclides was indicated: /sup 144/Ce, and /sup 144/Pr in the bone (I) (20 x 10/sup -12/ counts/g. fresh wt.). Liver (II), and Kidneys (III); /sup 95/Zr and /sup 95/Nb in II and III; /sup 106/Rh, /sup 129m/Te, and /sup 129/Te in I, III, and muscles; and /sup 89/Sr, /sup 90/Sr, and /sup 90/Y in I, II, and III. Activities found in these organs were decidedly higher than those found in the control samples obtained from individuals who died of other than the so-called radiation sickness. Radiation dose received by the bones of Mr. Kuboyama was calculated to be approximately 8 r.e.p.

  11. Mr 40,000 and Mr 39,000 pertussis toxin substrates are increased in surgically denervated dog ventricular myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Hershberger, R.E.; Feldman, A.M.; Anderson, F.L.; Kimball, J.A.; Wynn, J.R.; Bristow, M.R. (Univ. of Utah School of Medicine, Salt Lake City (USA))

    1991-04-01

    To test the general hypothesis that cardiac innervation may participate in myocardial G protein regulation, we examined the effects of complete intrapericardial surgical denervation or sham operation in dogs. In particulate fractions of dog left ventricular (LV) myocardium harvested 28-33 days after denervation or sham operation, Mr 40,000 and Mr 39,000 pertussis toxin-sensitive substrates (G proteins) were increased by 31% (1.31 +/- 0.084 vs 1.00 +/- 0.058 OD, arbitrary units, p less than 0.01) and 40% (1.40 +/- 0.117 vs. 1.000 +/- 0.084 OD, arbitrary units, p less than 0.02), respectively, as compared with sham-operated controls. The Mr 40,000 pertussis toxin-sensitive band comigrated with a pertussis toxin-sensitive substrate in human erythrocyte membranes known to contain an alpha Gi species. In these same preparations basal, GTP and GppNHp stimulated adenylate cyclase activities were decreased in denervated heart by 20, 26, and 19%, respectively, consistent with increased activity of an inhibitory G protein. In contrast, Gs function was not altered, because cyc(-) membranes reconstituted with membrane extracts and fluoride and beta-receptor-stimulated adenylate cyclase activity were not different between groups. Furthermore, adenylate cyclase catalytic subunit function as assessed with forskolin and manganese stimulation was not different between preparations of control and denervated heart. We conclude that in preparations of surgically denervated dog myocardium Mr 40,000 and Mr 39,000 pertussis toxin-sensitive G proteins are increased by 31 and 40%, respectively, and that functional alterations in adenylate cyclase activity exist, consistent with increased inhibitory G-protein function.

  12. Mr 40,000 and Mr 39,000 pertussis toxin substrates are increased in surgically denervated dog ventricular myocardium

    International Nuclear Information System (INIS)

    Hershberger, R.E.; Feldman, A.M.; Anderson, F.L.; Kimball, J.A.; Wynn, J.R.; Bristow, M.R.

    1991-01-01

    To test the general hypothesis that cardiac innervation may participate in myocardial G protein regulation, we examined the effects of complete intrapericardial surgical denervation or sham operation in dogs. In particulate fractions of dog left ventricular (LV) myocardium harvested 28-33 days after denervation or sham operation, Mr 40,000 and Mr 39,000 pertussis toxin-sensitive substrates (G proteins) were increased by 31% (1.31 +/- 0.084 vs 1.00 +/- 0.058 OD, arbitrary units, p less than 0.01) and 40% (1.40 +/- 0.117 vs. 1.000 +/- 0.084 OD, arbitrary units, p less than 0.02), respectively, as compared with sham-operated controls. The Mr 40,000 pertussis toxin-sensitive band comigrated with a pertussis toxin-sensitive substrate in human erythrocyte membranes known to contain an alpha Gi species. In these same preparations basal, GTP and GppNHp stimulated adenylate cyclase activities were decreased in denervated heart by 20, 26, and 19%, respectively, consistent with increased activity of an inhibitory G protein. In contrast, Gs function was not altered, because cyc(-) membranes reconstituted with membrane extracts and fluoride and beta-receptor-stimulated adenylate cyclase activity were not different between groups. Furthermore, adenylate cyclase catalytic subunit function as assessed with forskolin and manganese stimulation was not different between preparations of control and denervated heart. We conclude that in preparations of surgically denervated dog myocardium Mr 40,000 and Mr 39,000 pertussis toxin-sensitive G proteins are increased by 31 and 40%, respectively, and that functional alterations in adenylate cyclase activity exist, consistent with increased inhibitory G-protein function

  13. High-field MR imaging of spinal cord multiple sclerosis

    International Nuclear Information System (INIS)

    De La Paz, R.L.; Floris, R.; Norman, D.; Enzmann, D.R.

    1987-01-01

    Fifty-one high-field MR imaging studies (1.5 T, General Electric Signa) of the spinal cord were performed in 42 patients (27 female, 15 male; mean age, 40 years) with clinically definitive (n = 34) or probable (n = 8) multiple sclerosis and suspected spinal cord lesions. MR imaging showed focal spinal cord abnormalities in 38 (75%) of 51 studies. T2-weighted images were abnormal (showing foci of high signal intensity) in 38 studies, T1-weighted images were abnormal (showing areas of low signal intensity or mass effect) in 16 (42%) of 38, and GRASS images were abnormal (showing foci of high signal intensity) in 9 (82%) of 11 cases. Brain MR imaging showed periventricular lesions typical of multiple sclerosis in 34 (81%) of 42 studies. Spinal cord studies were positive in eight cases with normal brain MR images, and brain studies were positive in 13 instances of normal spinal cord MR images. Four lesions were at the cervicomedullary junction, 44 in the cervical spinal cord, and three in the thoracic cord. Mass effect in cord lesions, simulating neoplasm, was seen in seven patients during the acute symptomatic phase. Serial studies in three patients with decreasing symptoms showed a reduction after 3-4 weeks and resolution of the mass effect after 2-6 months

  14. MR imaging of posttraumatic spinal ligament injury

    International Nuclear Information System (INIS)

    Pathria, M.N.; Emery, S.; Masaryk, T.J.; Wilber, R.G.; Bohlman, H.

    1988-01-01

    The accuracy of MR imaging in the detection of ligamentous injury was evaluated in 29 patients (24 male, five female) with spinal injury resulting in fractures (n=27), evidence of instability (n=11), or neurologic deficit (n=2). MR examinations were performed acutely (average, 7.5 days posttrauma) with T1- and T2-weighted imaging and were blindly evaluated. Subsequently, plain films (n=27), tomograms (n=10), and CT scans (n=22) were evaluated. Eighteen patients underwent surgery. Fourteen patients had torn ligaments as indicated by clinical and surgical findings. MR imaging demonstrated ligament damage in 13. One case imaged 40 days following trauma was not detected. No patients with intact ligaments had evidence of ligamentous damage on MR images. MR imaging demonstrated retropulsed fractures in six patients in whom the posterior longitudinal ligament was intact but displaced from the vertebra. MR imaging was more reliable than radiography and CT for detection of ligamentous injury, and T2- weighted sequences are essential in such cases

  15. Cosmological wheel of time: A classical perspective of f(R) gravity

    Science.gov (United States)

    Yadav, Bal Krishna; Verma, Murli Manohar

    It is shown that the structures in the universe can be interpreted to show a closed wheel of time, rather than a straight arrow. An analysis in f(R) gravity model has been carried out to show that due to local observations, a small arc at any given spacetime point would invariably indicate an arrow of time from past to future, though on a quantum scale it is not a linear flow but a closed loop, a fact that can be examined through future observations.

  16. MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Schernthaner, Melanie; Pinker, Katja; Kapetas, Panagiotis; Bernathova, Maria; Polanec, Stephan H.; Bickel, Hubert; Wengert, Georg J.; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2016-11-15

    The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients underwent 487 MR-guided VABB using three different 8-10-gauge-VABB devices (Atec-9-gauge,A; Mammotome-8-gauge,M; Vacora-10-gauge,V). VABB data (lesion-type, size, biopsy device, histopathology) were compared to final diagnosis (surgery, n = 210 and follow-up, n = 277). Chi-square, and Kruskal-Wallis tests were applied. P values < 0.05 were considered significant. Final diagnosis was malignant in 104 (21.4 %), high risk in 64 (13.1 %) and benign in 319 (65.5 %) cases. Eleven of 328 (3.4 %) benign-rated lesions were false-negative (1/95, 1.1 %, A; 2/73, 2.7 %, M; 8/160 5.0 % V; P = 0.095). Eleven high-risk (11/77, 14.3 %) lesions proved to be malignant (3/26, 11.5 % A; 4/12, 33.3 % M; 4/39, 10.3 % V; P = 0.228). Five of 34 (14.7 %) DCIS were upgraded to invasive cancer (2/15, 13.3 %, A; 1/6, 16.6 % M; 2/13, 15.3 %, V; P = 0.977). Lesion size (P = 0.05) and type (mass vs. non-mass, P = 0.107) did not differ significantly. MR-guided VABB is an accurate method for diagnosis of MRI-only lesions. No significant differences on false-negative and underestimation rates were observed between three different biopsy devices. (orig.)

  17. MR imaging and MR spectroscopy for characterization of cardiomyopathies in adolescents - preliminary results

    International Nuclear Information System (INIS)

    Beer, M.; Buchner, S.; Fuchs, J.; Machann, W.; Ritter, C.O.; Beissert, M.; Darge, K.; Hahn, D.; Koestler, H.; Wirbelauer, J.

    2007-01-01

    Purpose: Cardiomyopathy is a rare but life-threatening disease in children and adolescents. Recent studies reported morphological, functional or metabolic alterations of the heart. We discuss a combined MR imaging and 31 P MR spectroscopy (MRS) protocol allowing the analysis of interdependencies between these parameters. Since normal values of cardiac MR parameters in this age group are not available, we included studies of age-matched healthy adolescents. Materials and Methods: 2D-CINE was used to assess left ventricular (LV) parameters. Additional 3D-Chemical Shift Imaging (3D-CSI) and Spectral Localization with Optimal Pointspread Function (SLOOP) reconstruction allowed quantification of the cardiac energy metabolism. Patients (n = 4; all male; age 16.8 ± 2.9 years) were included on the basis of an echocardiographic diagnosis of possible cardiomyopathy. The same protocol was applied to healthy young volunteers (n = 4; 1 female, 3 male; age 15.5 ± 0.6 years). Results: The patients had a significantly higher LV mass index compared to the control group (147 ± 41 g/m2 versus 97 ± 16 g/m2; p = 0.04). The other LV parameters (including LV EF with 59 ± 22 % versus 67 ± 10 %) showed no significant differences. The phosphocreatine to adenosine triphosphate ratio (PCr/ATP-ratio) of the patients was reduced to 1.71 ± 0.40 versus 2.44 ± 0.30 (p = 0.01), combined with a tendency towards decreased PCr concentrations of 9.1 ± 2.5 versus 7.9 ± 1.0 mmol/kg. Conclusion: The combination of 31 P MR spectroscopy and MR imaging allows quantitative determination of morphologic, functional and metabolic alterations in adolescents with suspected cardiomyopathy in one examination procedure. The reduction of energy metabolism combined with unaltered global function may indicate a primary role of metabolism in the pathogenesis of cardiomyopathies in adolescents. (orig.)

  18. R Vittal Rao

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. R Vittal Rao. Articles written in Resonance – Journal of Science Education. Volume 1 Issue 12 December 1996 pp 78-80 Book Review. A Mathematician's Apology Mathematics and Creativity · R Vittal Rao · More Details Fulltext PDF ...

  19. N R Krishnaswamy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. N R Krishnaswamy. Articles written in Resonance – Journal of Science Education. Volume 1 Issue 1 January 1996 pp 56-62 Series Article. Learning Organic Chemistry Through Natural Products Natural Products - A Kaleidoscopic View · N R Krishnaswamy.

  20. Beam test of ferrite absorber in TRISTAN MR

    International Nuclear Information System (INIS)

    Tajima, T.; Asano, K.; Furuya, T.; Ishi, Y.; Kijima, Y.; Mitsunobu, S.; Sennyu, K.; Takahashi, T.

    1996-06-01

    A study on the effect of beams on the ferrite absorber was performed using TRISTAN MR. The tested absorber consists of a 300 mm-diam. copper pipe with 4 mm-thick ferrite inner layer, which was fabricated with Hot Isostatic Press (HIP) technique. No spark, damage, or degradation were observed up to the highest available single bunch current of 4.4 mA, i.e. 2.8x10 11 electrons per bunch, which is 8.5 times higher than that of KEKB low energy ring. The loss factor showed significant increase with bunch shortening, e.g. 2.6 V/pC at 4 mm was about 40% higher than the value predicted by the calculation assuming Gaussian bunch and no incoming power from outside of the chamber. (author)

  1. Quantification of fat using chemical shift imaging and 1H-MR spectroscopy in phantom model

    International Nuclear Information System (INIS)

    Peng Xingui; Ju Shenghong; Fang Fang; Teng Gaojun

    2010-01-01

    Objective: To evaluate the accuracy of chemical shift imaging (CSI) and MR spectroscopy (MRS) for fat quantification in phantom model. Methods: Eleven phantoms were made according to the volume percentage of fat ranging from 0 to 100% with an interval of 10%. The fat concentration in the phantoms were measured respectively by CSI and MRS and compared using one-sample t test. The correlation between the two methods was also analyzed. The concentration of saturated fatty acids (FS), unsaturated fatty acids (FU) and the poly, unsaturation degree (PUD) were calculated by using MRS. Results: The fat concentration was (48.0±1.0)%, (57.0±0.5)%, (67.3±0.6)%, (77.3± 0.6)%, (83.3±0.6)% and (91.0±1.0)% respectively with fat volume of 50% to 100% by CSI. The fat concentration was (8.3±0.6)%, (16.3±0.7)%, (27.7±0.6)%, (36.0±1.0)%, (43.5± 0.6)% and (56.5±1.0)% respectively with fat volume of 10% to 60% by MRS, the fat concentration were underestimated by CSI and MRS (P<0.05), and had high linear correlation with the real concentration in phantoms (CSI: r=0.998, MRS: r=0.996, P<0.01). There was also a linear correlation between two methods (r=0.992, P<0.01) but no statistically significant difference (paired- samples t test, t=-0.125, P=0.903). By using MRS, the relative ratio of FS and FU in fat were 0. 15 and 0.85, the PUD was 0.0325, respectively, and highly consistent with these in phantoms. Conclusion: Both CSI and MRS are efficient and accurate methods in fat quantification at 7.0 T MR. (authors)

  2. How often do surgeons intervene on shoulder labral lesions detected at MR examination? A retrospective review of MR examinations correlated with arthroscopy

    Science.gov (United States)

    2014-01-01

    Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320

  3. Bianchi type-I universe in f(R, T) modified gravity with quark matter and Λ

    Science.gov (United States)

    Ćaǧlar, Halife; Aygün, Sezgin

    2017-02-01

    In this study, we investigate homogeneous and anisotropic Bianchi type I universe in the presence of quark matter source in f(R, T) gravity (Harko et al. in Phys. Rev. D 84:024020, 2011) with cosmological constant Λ (where R is the Ricci scalar and T is the trace of the energy momentum tensor). For this aim we have used the anisotropy feature of Bianchi type I universe and equation of states (EoS) of quark matter. We explore the exact solution f(R,T)=R+2f(T) model for Bianchi type I universe model. When t→∞, we get very small cosmological constant value, this result agrees with recent observations.

  4. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    Science.gov (United States)

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  5. MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn's disease.

    Science.gov (United States)

    Laghi, Andrea; Paolantonio, Pasquale; Iafrate, Franco; Borrelli, Osvaldo; Dito, Lucia; Tomei, Ernesto; Cucchiara, Salvatore; Passariello, Roberto

    2003-01-01

    To report our experience using MR of the small bowel with polyethylene glycol (PEG) solution as an oral contrast agent in a population of adults and children with known Crohn's disease. 40 patients (29 males; 11 females), 15 adults (age range 24-52 years) and 25 children (age range 5-17 years), with known Crohn's disease, underwent MR of the small bowel using a supeconductive 1.5 T magnet, and polyethylene glycol solution as an oral contrast agent. The fixed amount of contrast agent was 750-1000 ml for adults and 10 ml/kg of body weight for children. The Crohn's Disease Activity Index (CDAI) was available in all patients. Our study protocol included the acquisition of T2-weighted half-Fourier single-shot turbo spin-echo (HASTE) sequences and true fast imaging in the steady-state precession (true-FISP) sequences, followed by the acquisition of "spoiled" 2D gradient echo T1-weighted sequences with fat suppression (FLASH, fast low-angle shot) or alternatively "spoiled" 3D (VIBE, volume interpolated breath-hold examination), acquired 70 seconds after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) (0,1 mmol/kg). A specific MR score was created and calculated for each patient and was compared by means of the Spearman rank with CDAI. In all patients no significant side effects were observed and the MR examination was well tolerated even by paediatric patients. In all cases MR showed a small bowel wall thickening (> 4 mm) in the terminal ileum, with lumen stenosis in 26 patients. In 3 cases pathological segments proximal to the terminal ileum were observed and in another 3 cases caecal involvement was visible. The MR examination was able to show abnormalities of perivisceral fat tissue in 15 patients, mesenteric lymphadenopathy in 1 patient and abdominal abscess in 1 case. The Spearman rank showed a statistically significant correlation between CDAI and the MR score (r = 0.91, P = 0,0001). MR using PEG as an oral contrast agent could be considered a test

  6. r m o gemson

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. R M O GEMSON. Articles written in Sadhana. Volume 41 Issue 12 December 2016 pp 1473-1490. A heuristic reference recursive recipe for adaptively tuning the Kalman filter statistics part-1: formulation and simulation studies · M R ANANTHASAYANAM M SHYAM MOHAN NAREN NAIK R M O ...

  7. 10 CFR 26.31 - Drug and alcohol testing.

    Science.gov (United States)

    2010-01-01

    ... Transportation Workplace Drug and Alcohol Testing Programs” (65 FR 41944; August 9, 2001) to collect specimens... could be construed as a potential conflict of interest. The forensic toxicologist may not be an employee... or drug metabolites in Federal workplace drug testing programs and the licensee or other entity...

  8. 77 FR 48111 - Branded Prescription Drug Fee; Correction

    Science.gov (United States)

    2012-08-13

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Part 51 [REG-112805-10] RIN 1545-BJ39 Branded Prescription Drug Fee; Correction AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice..., August 6, 2012 (77 FR 46653) relating to the branded prescription drug fee imposed by the Affordable Care...

  9. Hepatic Iron Quantification on 3 Tesla (3 T Magnetic Resonance (MR: Technical Challenges and Solutions

    Directory of Open Access Journals (Sweden)

    Muhammad Anwar

    2013-01-01

    Full Text Available MR has become a reliable and noninvasive method of hepatic iron quantification. Currently, most of the hepatic iron quantification is performed on 1.5 T MR, and the biopsy measurements have been paired with R2 and R2* values for 1.5 T MR. As the use of 3 T MR scanners is steadily increasing in clinical practice, it has become important to evaluate the practicality of calculating iron burden at 3 T MR. Hepatic iron quantification on 3 T MR requires a better understanding of the process and more stringent technical considerations. The purpose of this work is to focus on the technical challenges in establishing a relationship between T2* values at 1.5 T MR and 3 T MR for hepatic iron concentration (HIC and to develop an appropriately optimized MR protocol for the evaluation of T2* values in the liver at 3 T magnetic field strength. We studied 22 sickle cell patients using multiecho fast gradient-echo sequence (MFGRE 3 T MR and compared the results with serum ferritin and liver biopsy results. Our study showed that the quantification of hepatic iron on 3 T MRI in sickle cell disease patients correlates well with clinical blood test results and biopsy results. 3 T MR liver iron quantification based on MFGRE can be used for hepatic iron quantification in transfused patients.

  10. M R Anantharaman

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. M R Anantharaman. Articles written in Bulletin of Materials Science. Volume 24 Issue 6 December 2001 pp 623-631 Magnetic Materials. Tailoring magnetic and dielectric properties of rubber ferrite composites containing mixed ferrites · M R Anantharaman K A Malini S Sindhu ...

  11. B R Venugopal

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences. B R Venugopal. Articles written in Journal of Chemical Sciences. Volume 124 Issue 2 March 2012 pp 385-393. Transition metal oxide loaded MCM catalysts for photocatalytic degradation of dyes · Divya Jyothi Parag A Deshpande B R Venugopal Srinivasan Chandrasekaran ...

  12. T R Ramadas

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. T R Ramadas. Articles written in Resonance – Journal of Science Education. Volume 4 Issue 7 July 1999 pp 79-82 Research News. The Work of the Fields Medallists: 1998 - Maxim Kontsevich · T R Ramadas · More Details Fulltext PDF ...

  13. V R Padmawar

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. V R Padmawar. Articles written in Resonance – Journal of Science Education. Volume 1 Issue 5 May 1996 pp 49-58 General Article. Sampling, Probability Models and Statistical Reasoning Statistical Inference · Mohan Delampady V R Padmawar · More Details ...

  14. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  15. Digital Signal Processor for Data Transfer and Processing in MR Tomography

    Czech Academy of Sciences Publication Activity Database

    Smékal, Z.; Gescheidtová, E.; Bartušek, Karel; Dokoupil, Zdeněk

    2005-01-01

    Roč. 13, č. 1 (2005), s. 39-48 ISSN 1738-6438 R&D Projects: GA AV ČR(CZ) IAA2065201 Keywords : MR tomography * DSP96002 * preemphasis filter * communication interface Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  16. Omsättning, rörelseresultat och kapitalstruktur – Påverkas företags kapitalstruktur av förändringar i dess omsättning eller rörelseresultat?

    OpenAIRE

    Lisstorp, Mattias; Steinberger, Paul

    2012-01-01

    Syftet med uppsatsen är att undersöka hur omsättning och rörelseresultat har samband med företagets kapitalstruktur. Resultaten jämförs med befintlig teori för att verifiera de teoretiska ansatserna. Regressionsanalys av tidsserier för 32 svenska börsnoterade företag med mer än 20 miljarder svenska kronor i omsättning 2010 har använts vid den här undersökningen. Data från åren 2004 till 2010 till varje företag är tagen från databasen ”Affärsdata” och undersöks genom regressionsanalys. Först u...

  17. Models of collapsing and expanding anisotropic gravitating source in f(R, T) theory of gravity

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, G. [The Islamia University of Bahawalpur, Department of Mathematics, Bahawalpur (Pakistan); Ahmed, Riaz [The Islamia University of Bahawalpur, Department of Mathematics, Bahawalpur (Pakistan); University of the Central Punjab, Department of Mathematics, Lahore (Pakistan)

    2017-07-15

    In this paper, we have formulated the exact solutions of the non-static anisotropic gravitating source in f(R, T) gravity which may lead to expansion and collapse. By assuming there to be no thermal conduction in gravitating source, we have determined parametric solutions in f(R, T) gravity with a non-static spherical geometry filled using an anisotropic fluid. We have examined the ranges of the parameters for which the expansion scalar becomes negative and positive, leading to collapse and expansion, respectively. Further, using the definition of the mass function, the conditions for the trapped surface have been explored, and it has been investigated that there exists a single horizon in this case. The impact of the coupling parameter λ has been discussed in detail in both cases. For the various values of the coupling parameter λ, we have plotted the energy density, anisotropic pressure and anisotropy parameter in the cases of collapse and expansion. The physical significance of the graphs has been explained in detail. (orig.)

  18. Progesterone-associated proteins PP12 and PP14 in the human endometrium.

    Science.gov (United States)

    Rutanen, E M; Koistinen, R; Seppälä, M; Julkunen, M; Suikkari, A M; Huhtala, M L

    1987-01-01

    Two proteins, designated as PP12 and PP14 were originally isolated from soluble extracts of the human placenta and its adjacent membranes. We have shown that they are synthesized by decidualized/secretory endometrium and not by placenta. Both proteins occur at high concentrations in human amniotic fluid, which is therefore an excellent source for purification. PP12 is a 34-kDa glycoprotein, which has an N-terminal amino acid sequence of Ala-Pro-Trp-Gln-Cys-Ala-Pro-Cys-Ser-Ala. This is identical with that of somatomedin-binding protein purified from the amniotic fluid. PP12 too binds somatomedin-C, or IGF-I (insulin-like growth factor-I). Human secretory endometrium synthesizes and secretes PP12, and progesterone stimulates its secretion. PP14 is a 28-kDa glycoprotein. Its N-terminal sequence shows homology to that of beta-lactoglobulins from various species. We have found PP14 in the human endometrium, serum and milk. Immunologically, PP14 is related to progestagen-associated endometrial protein (PEP), alpha-2 pregnancy-associated endometrial protein (alpha-2, PEG), endometrial protein 15 (EP15), alpha-uterine protein (AUP) and chorionic alpha-2 microglobulin (CAG-2). In ovulatory menstrual cycles, the concentration of PP14 increases in endometrial tissue as the secretory changes advance. In serum, the PP14 concentration begins to rise later than the progesterone levels, and high serum PP14 levels are maintained for the first days of the next cycle. By contrast, no elevation of serum PP14 level is seen in anovulatory cycles. Our results show that progesterone-associated proteins are synthesized by the human endometrium and appear in the peripheral circulation, where they can be quantitatively measured using immunochemical techniques.

  19. A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Li, Saying; Chen, Min; Wang, Wenchao; Zhao, Weifeng; Zhou, Cheng (Dept. of Radiology, Beijing Hospital, Beijing (China)), e-mail: chenmin62@yahoo.com; Wang, Jianye (Dept. of Urology, Beijing Hospital, Beijing (China)); Zhao, Xuna (Philips Medical System (China))

    2011-04-15

    Background: MR elastography is a new imaging tool capable of non-invasively assessing the viscoelastic properties of tissues. The clinical application of MR elastography in the diagnosis of prostate cancer remains to be elucidated. Purpose: To investigate the feasibility of MR elastography in the diagnosis of prostate cancer at 3.0T, and to assess the elasticity and viscosity of prostate cancer and benign prostatic disease. Material and Methods: Eight patients (63 +- 7.25 years old) with 12 foci of prostate cancer and 10 patients (59 +- 3.25 years old) with 14 foci of prostatitis in the peripheral zone were evaluated by MRE. Ten healthy volunteers (41 +- 4.32 years old) with 18 ROIs in the peripheral zone of the prostate were also assessed with MR elastography as a control group. The results were confirmed by histopathological findings. All examinations were performed on a 3.0T Philips Achieva scanner. MRE was implemented by transmitting low-frequency longitudinal mechanical waves of 100Hz into the prostate with a transducer placed above the pubic bones. The phase images were reconstructed to acquire viscoelastic mapping. T-test was used to compare the mean elasticity and viscosity of prostate cancer and prostatitis. A comparison of prostate cancer and healthy prostate tissue in elasticity was also evaluated. The correlation of elasticity and Gleason scores between prostate cancer and prostatitis were retrospectively analyzed with Pearson Correlation. Results: The mean elasticity and viscosity were significantly higher in the lesions with prostate cancer (6.55 +- 0.47 kPa, 6.56 +- 0.99 Pa.s, respectively) than in regions with prostatitis (1.99 +- 0.66 kPa, 2.13 +- 0.21 Pa.s). The difference between prostate cancer and prostatitis was statistically significant (t = 19.392, p < 0.01; t = 16.372, p < 0.01). The elasticity and viscosity of the healthy peripheral zone of prostate were 2.26 +- 0.45 kPa, 2.38 +- 0.54 Pa.s, respectively. There also was significant

  20. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)

  1. MR image findings on advanced internal derangement of the temporomandibular joints. Cases of disc position changed from anterior disc displacement with reduction to without reduction

    International Nuclear Information System (INIS)

    Igarashi, Chinami; Kobayashi, Kaoru; Yuasa, Masao; Imanaka, Masahiro; Yamamoto, Akira

    2005-01-01

    This study was designed to evaluate the suggestion that the clinical findings and MR image findings of anterior disc displacement with reduction cases could not reduce the disc displacement within the follow-up period. We selected 26 joints without remarkable bone changes in the condylar head or glenoid fossa in which reduction disappeared during follow-up. Clinical evaluation focused on temporomandibular pain, trismus, and joint sound. MR imaging was targeted for configuration of articular disc, degree of disc displacement, and condylar head position. Clinical signs observed with progression of the condition were disappearance of joint sound in 12/26 joints (46.1%), temporomandibular pain in 15/26 joints (57.6%), and decreased distance of opening mouth in 19/26 joints (73%). MR image findings were disc configuration changes in 12/26 joints (46.1%), increased degree of anterior displacement of disc in 20/26 joints (76.9%), and condylar head position changes in 9/26 joints (34.6%). It is suggested that the advanced stage of internal derangement is closely associated with the degree of disc displacement. (author)

  2. Thermodynamic geometry of black holes in f(R) gravity

    International Nuclear Information System (INIS)

    Soroushfar, Saheb; Saffari, Reza; Kamvar, Negin

    2016-01-01

    In this paper, we consider three types (static, static charged, and rotating charged) of black holes in f(R) gravity. We study the thermodynamical behavior, stability conditions, and phase transition of these black holes. It is shown that the number and type of phase transition points are related to different parameters, which shows the dependency of the stability conditions to these parameters. Also, we extend our study to different thermodynamic geometry methods (Ruppeiner, Weinhold, and GTD). Next, we investigate the compatibility of curvature scalar of geothermodynamic methods with phase transition points of the above black holes. In addition, we point out the effect of different values of the spacetime parameters on the stability conditions of mentioned black holes. (orig.)

  3. Cusp singularities in f(R) gravity: pros and cons

    International Nuclear Information System (INIS)

    Chen, Pisin; Yeom, Dong-han

    2015-01-01

    We investigate cusp singularities in f(R) gravity, especially for Starobinsky and Hu-Sawicki dark energy models. We illustrate that, by using double-null numerical simulations, a cusp singularity can be triggered by gravitational collapses. This singularity can be cured by adding a quadratic term, but this causes a Ricci scalar bump that can be observed by an observer outside the event horizon. Comparing with cosmological parameters, it seems that it would be difficult to see super-Planckian effects by astrophysical experiments. On the other hand, at once there exists a cusp singularity, it can be a mechanism to realize a horizon scale curvature singularity that can be interpreted by a firewall

  4. Anomalous magnetoresistance in antiferromagnetic polycrystalline materials R2Ni3Si5 (R=rare earth)

    International Nuclear Information System (INIS)

    Mazumdar, C.; Nigam, A.K.; Nagarajan, R.; Gupta, L.C.; Chandra, G.; Padalia, B.D.; Godart, C.; Vijayaraghaven, R.

    1997-01-01

    Magnetoresistance (MR) studies on polycrystalline R 2 Ni 3 Si 5 , (R=Y, rare earth) which order antiferromagnetically at low temperatures, are reported here. MR of the Nd, Sm, and Tb members of the series exhibit positive giant magnetoresistance, largest among polycrystalline materials (85%, 75%, and 58% for Tb 2 Ni 3 Si 5 , Sm 2 Ni 3 Si 5 , and Nd 2 Ni 3 Si 5 , respectively, at 4.4 K in a field of 45 kG). These materials have, to the best of our knowledge, the largest positive GMR reported ever for any bulk polycrystalline compounds. The magnitude of MR does not correlate with the rare earth magnetic moments. We believe that the structure of these materials, which can be considered as a naturally occurring multilayer of wavy planes of rare earth atoms separated by Ni endash Si network, plays a role. The isothermal MR of other members of this series (R=Pr,Dy,Ho) exhibits a maximum and a minimum, below their respective T N close-quote s. We interpret these in terms of a metamagnetic transition and short-range ferromagnetic correlations. The short-range ferromagnetic correlations seem to be dominant in the temperature region just above T N . copyright 1997 American Institute of Physics

  5. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  6. Tensor hypercontracted ppRPA: Reducing the cost of the particle-particle random phase approximation from O(r 6) to O(r 4)

    International Nuclear Information System (INIS)

    Shenvi, Neil; Yang, Yang; Yang, Weitao; Aggelen, Helen van

    2014-01-01

    In recent years, interest in the random-phase approximation (RPA) has grown rapidly. At the same time, tensor hypercontraction has emerged as an intriguing method to reduce the computational cost of electronic structure algorithms. In this paper, we combine the particle-particle random phase approximation with tensor hypercontraction to produce the tensor-hypercontracted particle-particle RPA (THC-ppRPA) algorithm. Unlike previous implementations of ppRPA which scale as O(r 6 ), the THC-ppRPA algorithm scales asymptotically as only O(r 4 ), albeit with a much larger prefactor than the traditional algorithm. We apply THC-ppRPA to several model systems and show that it yields the same results as traditional ppRPA to within mH accuracy. Our method opens the door to the development of post-Kohn Sham functionals based on ppRPA without the excessive asymptotic cost of traditional ppRPA implementations

  7. The miR-10 microRNA precursor family

    DEFF Research Database (Denmark)

    Tehler, Disa; Høyland-Kroghsbo, Nina Molin; Lund, Anders H

    2011-01-01

    The miR-10 microRNA precursor family encodes a group of short non-coding RNAs involved in gene regulation. The miR-10 family is highly conserved and has sparked the interest of many research groups because of the genomic localization in the vicinity of, coexpression with and regulation of the Hox...... gene developmental regulators. Here, we review the current knowledge of the evolution, physiological function and involvement in cancer of this family of microRNAs....

  8. Low energy bar pp physics

    International Nuclear Information System (INIS)

    Amsler, C.; Crowe, K.

    1989-02-01

    A detailed investigation of proton-antiproton interactions at low energy has become feasible with the commissioning of the LEAR facility in 1983. We shall shortly review the status of bar pp annihilation at rest and the physics motivations for second generation experiments with the Crystal Barrel detector. This type of detector would be adequate for the study of both Kp and bar pp interactions on an extracted beam of the KAON Factory. We shall conclude with a few remarks on the physics opportunities with bar p's at the KAON Factory which, in our opinion, will not be covered by the present LEAR facility. 11 refs., 10 figs., 2 tabs

  9. MR staging of malignant musculoskeletal tumors: An experimental study on MR and pathologic correlation of rabbit VX-2 carcinoma

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Chung, Sung Hoon; KIm, Cheol Woo; Kim, Seong Moon; Im, Jung Gi; Han, Man Chung

    1993-01-01

    To evaluate the reliability of MR imaging in tissue characterization and depiction of tumor boundaries, we performed MR pathologic correlation using parosteally implanted VX-2 carcinoma in 17 rabbit thighs. T1-weighted, T2-weighted and Gd-DTPA enhanced T1-weighted axial images were obtained 10-30 days after tumor implantation. After the animals were killed, frozen and sectioned along the MR imaging planes, and histopathologic examination were done. For accurate MR pathologic correlation, rabbit were fixed on the cardboard plate to minimize position change during the procedure. Tumor boundaries depicted on MR images were larger than those depicted on the specimen. Small tumors were surrounded by capsule-like loose connective tissue. Loose connective tissue became compact with tumor growth. This connective tissue showed high signal intensity on both T2-weighted and Gd-DTPA enhanced T1-weighted images. Muscle atrophy with fatty tissue accumulation around the tumor also contributed to the high signal intensity on MR images. Peritumoral edema and inflammatory reaction were not remarkable. Six of 8 cases with bone marrow fibrosis were detected on MR images. We concluded that peritumoral loose connective tissue and muscle atrophy exaggerated the size of experimentally induced malignant musculoskeletal tumors on MR images

  10. R B Misra

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. R B Misra. Articles written in Sadhana. Volume 34 Issue 2 April 2009 pp 235-241. Sequential Bayesian technique: An alternative approach for software reliability estimation · S Chatterjee S S Alam R B Misra · More Details Abstract Fulltext PDF. This paper proposes a sequential Bayesian ...

  11. R M Sangshetti

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. R M Sangshetti. Articles written in Bulletin of Materials Science. Volume 34 Issue 5 August 2011 pp 1027-1031. Combustion synthesis and structural characterization of Li–Ti mixed nanoferrites · R M Sangshetti V A Hiremath V M Jali · More Details Abstract Fulltext PDF.

  12. P R Viswanath

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. P R Viswanath. Articles written in Sadhana. Volume 32 Issue 1-2 February-April 2007 pp 83-92. Some thoughts on separation control strategies · P R Viswanath · More Details Abstract Fulltext PDF. Separation control has received considerable emphasis in literature both owing to fundamental ...

  13. Shridhar R Gadre

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. Shridhar R Gadre. Articles written in Resonance – Journal of Science Education. Volume 4 Issue 2 February 1999 pp 8-19 Series Article. Electrostatics in Chemistry - Basic Principles · Shridhar R Gadre Pravin K Bhadane · More Details Fulltext PDF. Volume 4 ...

  14. Gas kinematics and star formation in the filamentary molecular cloud G47.06+0.26

    Science.gov (United States)

    Xu, Jin-Long; Xu, Ye; Zhang, Chuan-Peng; Liu, Xiao-Lan; Yu, Naiping; Ning, Chang-Chun; Ju, Bing-Gang

    2018-01-01

    Aims: We performed a multi-wavelength study toward the filamentary cloud G47.06+0.26 to investigate the gas kinematics and star formation. Methods: We present the 12CO (J = 1-0), 13CO (J = 1-0) and C18O (J = 1-0) observations of G47.06+0.26 obtained with the Purple Mountain Observation (PMO) 13.7 m radio telescope to investigate the detailed kinematics of the filament. Radio continuum and infrared archival data were obtained from the NRAO VLA Sky Survey (NVSS), the APEX Telescope Large Area Survey of the Galaxy (ATLASGAL), the Galactic Legacy Infrared Mid-Plane Survey Extraordinaire (GLIMPSE) survey, and the Multi-band Imaging Photometer Survey of the Galaxy (MIPSGAL). To trace massive clumps and extract young stellar objects in G47.06+0.26, we used the BGPS catalog v2.0 and the GLIMPSE I catalog, respectively. Results: The 12CO (J = 1-0) and 13CO (J = 1-0) emission of G47.06+0.26 appear to show a filamentary structure. The filament extends about 45' (58.1 pc) along the east-west direction. The mean width is about 6.8 pc, as traced by the 13CO (J = 1-0) emission. G47.06+0.26 has a linear mass density of 361.5 M⊙pc-1. The external pressure (due to neighboring bubbles and H II regions) may help preventing the filament from dispersing under the effects of turbulence. From the velocity-field map, we discern a velocity gradient perpendicular to G47.06+0.26. From the Bolocam Galactic Plane Survey (BGPS) catalog, we found nine BGPS sources in G47.06+0.26, that appear to these sources have sufficient mass to form massive stars. We obtained that the clump formation efficiency (CFE) is 18% in the filament. Four infrared bubbles were found to be located in, and adjacent to, G47.06+0.26. Particularly, infrared bubble N98 shows a cometary structure. CO molecular gas adjacent to N98 also shows a very intense emission. H II regions associated with infrared bubbles can inject the energy to surrounding gas. We calculated the kinetic energy, ionization energy, and thermal energy

  15. Diagnostic performance of diffusion-weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot

    International Nuclear Information System (INIS)

    Abdel Razek, Ahmed Abdel Khalek; Samir, Sieza

    2017-01-01

    Highlights: • Excellent inter-observer agreement of ADC of bony lesions in diabetic foot. • ADC can differentiate diabetic osteoarthropathy from osteomylitis. • Diffusion MR imaging can added to routine MR imaging of diabetic foot. - Abstract: Purpose: To study the diagnostic performance of diffusion weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot. Patients and methods: This prospective study was carried out on 41 patients with diabetic foot, 22 males and 19 females with mean age of 51 years. They underwent diffusion-weighted MR imaging of the foot. The apparent diffusion coefficient (ADC) values of the bony lesions were calculated by two reviewers and correlated with the surgical findings or biopsy. The kappa statistic (k) was used to estimate the proportion of inter-observer agreement of two reviewers. Results: The mean ADC of acute diabetic osteoarthropathy was 1.27 ± 0.19 × 10 −3 mm 2 /s for reviewer 1 and 1.26 ± 0.21 × 10 −3 mm 2 /s for reviewer 2. The mean ADC value in diabetic osteomyelitis was 0.86 ± 0.11 × 10 −3 mm 2 /s for reviewer 1 and 0.85 ± 0.12 × 10 −3 mm 2 /s for reviewer 2. There was excellent inter-observer agreement of ADC value of bony lesions in diabetic foot by both reviewers (K = 0.93). There was statistically significant difference in the ADC values of both groups (P = 0.001). The cut-off point of ADC value of both reviewers used in differentiating acute diabetic osteoarthropathy and osteomyelitis were 0.98 × 10 −3 mm 2 /s and 1.04 × 10 −3 mm 2 /s with an accuracy of 94% and 93% and area under the curve of 0.94 and 0.93 respectively. Conclusion: We conclude that the ADC value is a non-invasive imaging parameter that can help in differentiation of diabetic osteoarthropathy from osteomyelitis with excellent inter-observer agreement.

  16. 78 FR 7852 - Qualification of Drivers; Exemption Applications; Diabetes Mellitus

    Science.gov (United States)

    2013-02-04

    ... license from New York. Isaias Gomez Mr. Gomez, 54, has had ITDM since 2009. His endocrinologist examined..., Associate Administrator for Policy. [FR Doc. 2013-02268 Filed 2-1-13; 8:45 am] BILLING CODE P ...

  17. Volume-assisted estimation of liver function based on Gd-EOB-DTPA-enhanced MR relaxometry

    Energy Technology Data Exchange (ETDEWEB)

    Haimerl, Michael; Schlabeck, Mona; Verloh, Niklas; Fellner, Claudia; Stroszczynski, Christian; Wiggermann, Philipp [University Hospital Regensburg, Department of Radiology, Regensburg (Germany); Zeman, Florian [University Hospital Regensburg, Center for Clinical Trials, Regensburg (Germany); Nickel, Dominik [MR Applications Development, Siemens AG, Healthcare Sector, Erlangen (Germany); Barreiros, Ana Paula [University Hospital Regensburg, Department of Internal Medicine I, Regensburg (Germany); Loss, Martin [University Hospital Regensburg, Department of Surgery, Regensburg (Germany)

    2016-04-15

    To determine whether liver function as determined by indocyanine green (ICG) clearance can be estimated quantitatively from hepatic magnetic resonance (MR) relaxometry with gadoxetic acid (Gd-EOB-DTPA). One hundred and seven patients underwent an ICG clearance test and Gd-EOB-DTPA-enhanced MRI, including MR relaxometry at 3 Tesla. A transverse 3D VIBE sequence with an inline T1 calculation was acquired prior to and 20 minutes post-Gd-EOB-DTPA administration. The reduction rate of T1 relaxation time (rrT1) between pre- and post-contrast images and the liver volume-assisted index of T1 reduction rate (LVrrT1) were evaluated. The plasma disappearance rate of ICG (ICG-PDR) was correlated with the liver volume (LV), rrT1 and LVrrT1, providing an MRI-based estimated ICG-PDR value (ICG-PDR{sub est}). Simple linear regression model showed a significant correlation of ICG-PDR with LV (r = 0.32; p = 0.001), T1{sub post} (r = 0.65; p < 0.001) and rrT1 (r = 0.86; p < 0.001). Assessment of LV and consecutive evaluation of multiple linear regression model revealed a stronger correlation of ICG-PDR with LVrrT1 (r = 0.92; p < 0.001), allowing for the calculation of ICG-PDR{sub est}. Liver function as determined using ICG-PDR can be estimated quantitatively from Gd-EOB-DTPA-enhanced MR relaxometry. Volume-assisted MR relaxometry has a stronger correlation with liver function than does MR relaxometry. (orig.)

  18. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167... for depreciation. The basis upon which the allowance for depreciation is to be computed with respect... property at that time, is the basis for computing depreciation. [T.D. 6500, 25 FR 11402, Nov. 26, 1960...

  19. MR-fluid yield surface determination in disc-type MR rotary brakes

    International Nuclear Information System (INIS)

    Farjoud, Alireza; Vahdati, Nader; Fah, Yap Fook

    2008-01-01

    Magneto-rheological (MR) fluids are currently attracting a great deal of attention because of their unique rheological behavior. Many devices have been designed using MR fluids, and of potential interest here are disc-type MR rotary brakes. The plug flow region in MR devices is defined as the region where the fluid is not flowing. The plug flow region plays an important role in design and analysis of MR devices. In MR dampers, the damping coefficient is a function of the plug thickness. In MR valves, the plug thickness is used to control the flow rate through, and the pressure drop across, the MR valve. A MR clutch is performing at the highest efficiency when the entire MR gap is the plug region. For an MR rotary brake, the highest restraining torque is obtained when the entire gap is the plug region as far as there are no wall slip effects. In this paper, using the Bercovier and Engelman constitutive model, the MR fluid flow in disc-type MR brakes is modeled to determine the plug flow region. The resulting system of equations is solved numerically. It is shown that the existence of a plug flow region in the brake will affect the control torque ratio. Better estimation of the plug flow region results in better estimation of the viscous torque

  20. Determination of {sup 10}Be, {sup 26}Al, and {sup 36}Cl in meteorites

    Energy Technology Data Exchange (ETDEWEB)

    Merchel, S.; Herpers [Koeln Univ. (Germany); Neumann, S.; Michel, R. [Hannover Univ. (Germany); Kubik, P.W.; Synal, H.A. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Suter, M. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Long-lived cosmogenic radionuclides were determined in stony ({sup 10}Be, {sup 26}Al) and iron ({sup 10}Be, {sup 26}Al, {sup 36}Cl) meteorites using AMS after radiochemical separation. A selection of these data is briefly discussed with respect to exposure histories of the meteorites and is compared to model calculations. (author) 2 figs., 5 refs.