WorldWideScience

Sample records for fluorescein angiography

  1. [Nursing care in fluorescein angiography].

    Science.gov (United States)

    Santos-Blanco, Feliciano

    2008-01-01

    Fluoresceinic angiography of the ocular fundus is a diagnostic technique to study retinal and choroidal circulation. This technique consists of parenteral administration of 500 mg of sodium fluorescein 10% and photographing the fluorescence in the eye vessels. Although this substance is fairly safe, it may also produce mild, moderate or severe local and/or general adverse reactions. The nursing process is routinely used in hospital units but not always in outpatient clinics, even through the use of invasive procedures with intravenous medication administration is common. Therefore, nurses, as those reponsible for intravenous administration, should use the nursing process to guarantee the quality of care required by the patient. To do this, we describe an individualized care plan based on evaluation by Marjorie Gordon's functional health patterns, NANDA's nursing diagnoses Taxonomy II, Nursing Outcomes Classification (NOC), Nursing Interventions Classifications (NIC) and potential complications of the procedure.

  2. Case Report of Bullous Pemphigoid following Fundus Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Goktug Demirci

    2010-05-01

    Full Text Available Purpose: To report a first case of bullous pemphigoid (BP following intravenous fluorescein for fundus angiography. Clinical Features: A 70-year-old male patient was admitted to the intensive care unit with BP and sepsis. He reported a history of fundus fluorescein angiography with a pre-diagnosis of senile macular degeneration 2 months prior to presentation. At that time, fluorescein extravasated at the antecubital region. Following the procedure, pruritus and erythema began at the wrists bilaterally, and quickly spread to the entire body. The patient also reported a history of allergy to human albumin solution (Plamasteril®; Abbott 15 years before, during bypass surgery. On dermatologic examination, erythematous patches were present on the scalp, chest and anogenital region. Vesicles and bullous lesions were present on upper and lower extremities. On day 2 of hospitalization, tense bullae appeared on the upper and lower extremities. The patient was treated with oral methylprednisolone 48 mg (Prednol®; Mustafa Nevzat, topical clobetasol dipropionate 0.05% cream (Dermovate®; Glaxo SmithKline, and topical 4% urea lotion (Excipial Lipo®; Orva for presumptive bullous pemphigoid. Skin punch biopsy provided tissue for histopathology, direct immunofluorescence examination, and salt extraction, which were all consistent with BP. After 1 month, the patient was transferred to the intensive care unit with sepsis secondary to urinary tract infection; he died 2 weeks later from sepsis and cardiac failure. Conclusions: To our knowledge, this is the first reported case of BP following fundus fluorescein angiography in a patient with known human albumin solution allergy. Consideration should be made to avoid fluorescein angiography, change administration route, or premedicate with antihistamines in patients with known human albumin solution allergy. The association between fundus fluorescein angiography and BP should be further investigated.

  3. Fluorescein angiography and retinal vascular development in premature infants.

    Science.gov (United States)

    Purcaro, Velia; Velia, Purcaro; Baldascino, Antonio; Antonio, Baldascino; Papacci, Patrizia; Patrizia, Papacci; Giannantonio, Carmen; Carmen, Giannantonio; Molisso, Anna; Anna, Molisso; Molle, Fernando; Fernando, Molle; Lepore, Domenico; Domenico, Lepore; Romagnoli, Costantino; Costantino, Romagnoli

    2012-10-01

    To investigate the role of fluorescein angiography (FA) in the management of retinopathy of prematurity (ROP) in preterm newborns. An observational case series of 13 extremely low birth weight infants. From September 2009 to March 2010, 13 newborn infants with a gestational age <29 weeks end/or birth weight <1000 g underwent serial fluorescein angiography with RetCam (Clarity, Pleasanton, CA) every 2 weeks. The fluorescein angiograms were examined to optimize the timing of diagnosis of ROP and to investigate development of retinal and choroidal vascularization. There were no side effects related to FA. Variable features of retinal and choroidal circulation in preterm infants with a high risk of developing ROP were noted. FA allows vessels branching at the junction between vascular and avascular retina (V-Av junction) to be viewed easily and shows the ROP findings that sometimes cannot be seen by indirect ophthalmoscopy. Dye leakage is the most significant sign of progression to severe ROP or the need for surgery in newborn babies with ROP. RetCam-assisted intravenous FA is safe and allows a more objective assessment of the ROP stage and zone.

  4. Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2013-01-01

    Full Text Available Purpose. This study examines the effects of fundus fluorescein angiography (FFA procedure on ocular pulse amplitude (OPA and intraocular pressure (IOP. Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was  mmHg and post-FFA mean OPA value was  mmHg (. Pre-FFA mean IOP value was  mmHg and post-FFA mean IOP value was  mmHg (. Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707.

  5. Ultra-widefield fluorescein angiography of white without pressure

    Directory of Open Access Journals (Sweden)

    Orlin A

    2013-05-01

    Full Text Available Anton Orlin, Aalya Fatoo, Joshua Ehrlich, Donald J D'Amico, RV Paul Chan, Szilárd KissDepartment of Ophthalmology, Weill Cornell Medical College, New York, NY, USAPurpose: To describe ultra-widefield fluorescein angiography (UWFA findings in eyes with white without pressure (WWOP and in eyes without any obvious peripheral chorioretinal disease, and to determine if a difference exists between these two groups.Methods: A retrospective review of 379 eyes undergoing diagnostic UWFA using the Optos 200Tx imaging system. Eyes were excluded if the quality of the color photograph or UWFA prevented reliable evaluation. Eyes were also excluded if there was any evidence of peripheral retinal or choroidal disease, which was thought to have an effect on UWFA (eg, peripheral background diabetic or hypertensive retinopathy, vein occlusion, or any other peripheral vascular disorder. Eyes were determined to have WWOP, based on a dilated fundus examination and color fundus photography that contained areas of peripheral retinal whitening consistent with the diagnosis. UWFA was evaluated by trained masked graders, and determined to have or not have peripheral vascular leakage and/or staining.Results: Of the 379 eyes evaluated, 45 eyes were included in the study. Twelve eyes were determined to have peripheral WWOP; 33 eyes did not have WWOP on examination or color fundus photography. Three common UWFA peripheral patterns were visualized. Eyes with and without WWOP were grouped into one of three patterns. The majority of eyes without WWOP demonstrated UWFA pattern one (69.7%, while those in the WWOP group demonstrated pattern three (50%. The distribution of UWFA patterns is statistically different between those with and without WWOP (P = 0.002. In eyes without WWOP, in patients with no documented systemic microvascular disease (diabetes, hypertension, 71.4% of eyes had UWFA pattern one while 14.3% had both patterns two and three.Conclusion: This study is one of the

  6. Ultra-widefield fluorescein angiography of white without pressure

    Science.gov (United States)

    Orlin, Anton; Fatoo, Aalya; Ehrlich, Joshua; D’Amico, Donald J; Chan, RV Paul; Kiss, Szilárd

    2013-01-01

    Purpose To describe ultra-widefield fluorescein angiography (UWFA) findings in eyes with white without pressure (WWOP) and in eyes without any obvious peripheral chorioretinal disease, and to determine if a difference exists between these two groups. Methods A retrospective review of 379 eyes undergoing diagnostic UWFA using the Optos 200Tx imaging system. Eyes were excluded if the quality of the color photograph or UWFA prevented reliable evaluation. Eyes were also excluded if there was any evidence of peripheral retinal or choroidal disease, which was thought to have an effect on UWFA (eg, peripheral background diabetic or hypertensive retinopathy, vein occlusion, or any other peripheral vascular disorder). Eyes were determined to have WWOP, based on a dilated fundus examination and color fundus photography that contained areas of peripheral retinal whitening consistent with the diagnosis. UWFA was evaluated by trained masked graders, and determined to have or not have peripheral vascular leakage and/or staining. Results Of the 379 eyes evaluated, 45 eyes were included in the study. Twelve eyes were determined to have peripheral WWOP; 33 eyes did not have WWOP on examination or color fundus photography. Three common UWFA peripheral patterns were visualized. Eyes with and without WWOP were grouped into one of three patterns. The majority of eyes without WWOP demonstrated UWFA pattern one (69.7%), while those in the WWOP group demonstrated pattern three (50%). The distribution of UWFA patterns is statistically different between those with and without WWOP (P = 0.002). In eyes without WWOP, in patients with no documented systemic microvascular disease (diabetes, hypertension), 71.4% of eyes had UWFA pattern one while 14.3% had both patterns two and three. Conclusion This study is one of the first to specifically evaluate peripheral vascular leakage/staining in eyes with WWOP as well as in eyes without any obvious peripheral chorioretinal disease. We demonstrate that

  7. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    Science.gov (United States)

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  8. Diabetic Macular Ischemia Diagnosis: Comparison between Optical Coherence Tomography Angiography and Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Jose Mauricio Botto de Barros Garcia

    2016-01-01

    Full Text Available Purpose. To compare fluorescein angiography (FA and optical coherence tomography angiography (OCTA images of foveal avascular zone (FAZ in patients with diabetic retinopathy (DR with and without diabetic macular ischemia (DMI. Methods. The Wilcoxon signed-rank test was used to compare area measurements and p values of <0.05 were considered statistically significant. FA and OCTA images were independently graded by 2 observers that reached agreement regarding quantitative DMI according established protocols. The ischemic area was divided into “large” macular ischemia (superior to 0.32 mm2 and “small” (inferior to 0.32 mm2 groups. Quantitative analyses of the FAZ were performed using custom software. Results. Thirty-four eyes from 34 diabetic patients were enrolled. Subjects with DMI presented a mean area on FA and OCTA of 0.68 ± 0.53 mm2 and 0.58 ± 0.35 mm2, respectively (p=0.1374. Patients without DMI presented a mean area on FA and OCTA of 0.19 ± 0.67 mm2 and 0.20 ± 0.79 mm2, respectively (p=0.9594. The ICC for the FAZ measurements between the 2 observers on FA and OCTA was 0.96 and 0.92, respectively. Conclusion. OCTA represents a novel technique for the diagnosis of DMI and it may become an alternative to FA for this purpose.

  9. Fluorescein angiography and changes in aqueous humor protein after argon laser photomydriasis in rabbits

    International Nuclear Information System (INIS)

    Denffer, H. v.; Erhardt, W.; Neiss, A.

    1979-01-01

    In brown-eyed and blue-eyed rabbits, irises treated with argon laser photomydriasis (ALP) were studied by using fluorescein angiography and by evaluating the aqueous humor protein concentration. The following results were obtained. Immediately after ALP, a breakdown of the blood-aqueous barrier is demonstrated by a marked influx of fluorescein into the ciliary processes and into the anterior and posterior chambers. The dye flow into the aqueous humor decreases to normal values within 3 days. There is no fluorescein leakage from laser impacts themselves. Peripupillary capillary loops are permanently occluded, but in a few cases, recanalization occurs. Neovascularization did not occur during 56 days of observation. ALP initially leads to a six- to eightfold increase in normal aqueous humor protein concentration, which returns to normal values within 3 days. (orig./AJ) 891 AJ/orig.- 892 MKO [de

  10. Ultra-widefield fluorescein angiography reveals retinal phlebitis in Susac's syndrome.

    Science.gov (United States)

    Klufas, Michael A; Dinkin, Marc J; Bhaleeya, Swetangi D; Chapman, Kristin O; Riley, Claire S; Kiss, Szilárd

    2014-01-01

    A 23-year-old woman with history of headaches and auditory changes presented with acute-onset visual field loss in the right eye. The combination of multiple retinal branch artery occlusions of the right eye on funduscopic examination, characteristic white matter lesions in the corpus callosum on magnetic resonance imaging, and hearing loss on audiometric testing led to a diagnosis of Susac's syndrome. Ultra-widefield fluorescein angiography revealed involvement of the retinal veins, which has not been previously reported with this condition. Additionally, ultra-widefield indocyanine green angiography demonstrated changes in the choroidal circulation, which are controversial in this syndrome. Copyright 2014, SLACK Incorporated.

  11. The significance of fluorescein angiography in the early diagnosis of lesions on ocular fundus at pseudoxanthoma elasticum patients.

    Science.gov (United States)

    Bogdanowski, T; Gluza, J; Rasiewicz, D

    1977-05-27

    The role of fluorescein angiography in early diagnosis of lesions on fundus of the eye at pseudoxanthoma elasticum patients has been shown. The authors show angiographic changes on the basis of three cases of pseudoxanthoma elasticum patients.

  12. A STUDY TO COMPARE FUNDUS FLUORESCEIN ANGIOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY IN AGE RELATED MACULAR DEGENERATION

    Directory of Open Access Journals (Sweden)

    Rani Sujatha

    2016-02-01

    Full Text Available PURPOSE To compare the diagnostic accuracy of optical coherence tomography with Fundus Fluorescein Angiography in diagnosing Age related macular degeneration. METHODS A total 25 patients newly diagnosed as Age related macular degeneration were included in the study. The study was done during the time period between August 2013 to November 2015 this is a prospective randomized hospital based study. RESULTS Maximum no of patients affected belonged to the age group of 50-70 years and 60% were females. The most common symptom was defective vision accounting for 92%. Hypertension and hyperlipidemia were the most common risk factors. 12% of the cases had unilateral disease and 88% had bilateral disease. 6% of eyes were normal in both FFA and OCT. 62% of the eyes by FFA and 61% of the eyes by OCT had dry ARMD and 32 % of the eye by FFA and 33 % by OCT had wet ARMD. CONCLUSION Fundus Fluorescein Angiography is the gold standard tool for screening ARMD and OCT is more specific in detecting early subretinal neovascular membrane and also to assess the activity of the neovascular membranes. Hence OCT is superior to FFA in diagnosing early wet ARMD and thus helps in early management of patients with ARMD.

  13. [Fluorescein angiography and optical coherence tomography findings in central fundus of myopic patients].

    Science.gov (United States)

    Avetisov, S E; Budzinskaya, M V; Zhabina, O A; Andreeva, I V; Plyukhova, A A; Kobzova, M V; Musaeva, G M

    2015-01-01

    Myopia prevalence grows alike in many countries, including Russia, regardless of geographical and population conditions. to assess fundus changes in myopic patients at different ocular axial lengths by means of modern diagnostic tools. The study enrolled 97 patients (194 eyes) aged 45 ± 20.17 years with myopia of different degrees. Besides a standard ophthalmic examination, all patients underwent fundus fluorescein angiography and optical coherence tomography. The occurrence of retinal pigment epithelium (RPE) atrophy (diffuse or focal) has been shown to increase with increasing ocular axial length. Only 27 eyes (28.1%) appeared intact. As myopia progression implies axial growth of the eye, it is associated with a more severe decrease in choroid, RPE, and photoreceptor layer thicknesses: the longer the anterior-posterior axis, the thinner the above mentioned fundus structures. Age-related changes in the fundus are also likely to be more pronounced in longer axes. Myopic traction maculopathy, which in our case appeared the main cause of increased retinal thickness, was diagnosed in 105 eyes, "outer" macular retinoschisis--in 40 eyes. Thus, modern diagnostic tools, such as fluorescein angiography and optical coherence tomography, enable objective assessment of the central fundus.

  14. EVALUATION OF DIABETIC MACULAR OEDEMA WITH SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY AND FUNDUS FLUORESCEIN ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mallika Venkitasubramanian

    2017-02-01

    Full Text Available BACKGROUND Macular oedema is an important cause of visual morbidity in Diabetic Retinopathy. It can be assessed by both Fundus Fluorescein Angiography (FFA and Optical Coherence Tomography (OCT. The aims of this study were to evaluate the agreement between morphological features on spectral domain Optical Coherence Tomography and Fluorescein Angiographic leakage patterns in Diabetic Macular Oedema, and to study the correlation between the best corrected visual acuity and central foveal thickness measured by Optical Coherence Tomography. MATERIALS AND METHODS This was an observational study. All patients with Diabetic Macular Oedema underwent complete ophthalmic examination and subjected to FFA and OCT. Presence or absence of macular oedema by FFA and OCT was noted and agreement between two modalities of imaging was assessed. Sensitivity of these modalities were also found out using appropriate statistical methods. Best Corrected Visual Acuity (BCVA measured were converted to LogMAR scale and Central foveal thickness measured by OCT. Linear regression analysis was done with central foveal thickness and LogMAR visual acuity. RESULTS A total of 69 eyes of 39 patients were studied. OCT revealed Diabetic Macular Oedema in 97.5% of eyes. Fundus Fluorescein Angiography performed in these patients identified leakage in 95.6% of eyes. Sensitivity and specificity of FFA and OCT were calculated keeping one as the gold standard for sensitivity and specificity of the other. FFA and OCT had almost equal sensitivity (95.46 for OCT and 96.92 for FFA for detection of DME. Specificity of OCT was found to be slightly higher (33.33% compared to FFA (25%. Our results suggest that there is minimal agreement between these two imaging modalities in evaluating DME. Statistically, Kappa value was 0.248. Linear regression analysis showed that central foveal thickness had a significant correlation with visual acuity, with Pearson correlation coefficient r=0.442, p=0

  15. Influence of Fluorescein Angiography on the Diagnosis and Management of Retinopathy of Prematurity

    Science.gov (United States)

    Klufas, Michael A.; Patel, Samir N.; Ryan, Michael C.; Gupta, Mrinali Patel; Jonas, Karyn E.; Ostmo, Susan; Martinez-Castellanos, Maria Ana; Berrocal, Audina M.; Chiang, Michael F.; Chan, R.V. Paul

    2016-01-01

    Purpose To examine the influence of fluorescein angiography (FA) on the diagnosis and management of retinopathy of prematurity (ROP). Design Prospective cohort study. Participants Nine recognized ROP experts (3 pediatric ophthalmologists; 6 retina specialists) interpreted 32 sets (16 color fundus photographs; 16 color fundus photographs paired with the corresponding FAs) of wide-angle retinal images from infants with ROP. Methods All experts independently reviewed the 32 image sets on a secure web site and provided a diagnosis and management plan for the case presented, first based on color fundus photographs alone, and then by color fundus photographs and corresponding FA. Main Outcome Measures Sensitivity and specificity of the ROP diagnosis (zone, stage, plus disease, and category – i.e. no ROP, mild ROP, type-2 ROP, and treatment-requiring ROP) was calculated using a consensus reference standard diagnosis, determined from the diagnosis of the color fundus photographs by three experienced readers in combination with the clinical diagnosis based on ophthalmoscopic examination. The kappa statistic was used to analyze the average intergrader agreement among experts for the diagnosis of zone, stage, plus disease, and category. Results Addition of FA to color fundus photographs resulted in a significant improvement in sensitivity for diagnosis of stage 3 or worse disease (39.8% vs. 74.1%, P = 0.008), type-2 or worse ROP (69.4% vs. 86.8%, P = 0.013), and pre-plus or worse disease (50.5 vs. 62.6%, P = 0.031). There was a nonsignificant trend towards improved sensitivity for diagnosis of treatment-requiring ROP (22.2% vs. 40.3%, P = 0.063). Using the kappa statistic, addition of FA to color fundus photographs significantly improved intergrader agreement for diagnosis of treatment-requiring ROP. Addition of FA to color fundus photographs did not significantly affect intergrader agreement for the diagnosis of stage, zone, or plus disease. Conclusions Compared to color

  16. Digital Integration Method (DIM): A new method for the precise correlation of OCT and fluorescein angiography

    International Nuclear Information System (INIS)

    Hassenstein, A.; Richard, G.; Inhoffen, W.; Scholz, F.

    2007-01-01

    The new integration method (DIM) provides for the first time the anatomically precise integration of the OCT-scan position into the angiogram (fluorescein angiography, FLA), using reference marker at corresponding vessel crossings. Therefore an exact correlation of angiographic and morphological pathological findings is possible und leads to a better understanding of OCT and FLA. Occult findings in FLA were the patient group which profited most. Occult leakages could gain additional information using DIM such as serous detachment of the retinal pigment epithelium (RPE) in a topography. So far it was unclear whether the same localization in the lesion was examined by FLA and OCT especially when different staff were performing and interpreting the examination. Using DIM this problem could be solved using objective markers. This technique is the requirement for follow-up examinations by OCT. Using DIM for an objective, reliable and precise correlation of OCT and FLA-findings it is now possible to provide the identical scan-position in follow-up. Therefore for follow-up in clinical studies it is mandatory to use DIM to improve the evidence-based statement of OCT and the quality of the study. (author) [de

  17. Acute Retinal Pigment Epitheliitis: Spectral Domain Optical Coherence Tomography, Fluorescein Angiography, and Autofluorescence Findings

    Directory of Open Access Journals (Sweden)

    Tuğba Aydoğan

    2015-01-01

    Full Text Available A 17-year-old presented with central and paracentral scotomas in his right eye for one week. There was no remarkable medical or ocular history. Blood analyses were within normal range. At presentation both eyes’ best-corrected visual acuities were 20/20. Slit-lamp examination result was normal. Fundus examination revealed yellow-white hypopigmented areas in the macula. Fluorescein angiography (FA showed hypofluorescence surrounded by ring of hyperfluorescence. Fundus autofluorescence (FAF was slightly increased. Spectral domain optical coherence tomography (SD-OCT showed disruption of IS/OS junction with expansion of abnormal hyperreflectivity from retinal pigment epithelium to the outer nuclear layer (ONL. One month later fundus examination showed disappearance of the lesions. FA revealed transmission hyperfluorescence. FAF showed increased autofluorescence and pigment clumping. Hyperreflective band in SD-OCT disappeared. Loss of photoreceptor segment layers was observed in some of the macular lesions. The diagnosis of acute retinal pigment epitheliitis can be challenging after disappearance of fundus findings. FA, FAF, and SD-OCT are important tests for diagnosis after resolution of the disease.

  18. Analysis of Fundus Photography and Fluorescein Angiography in Nonarteritic Anterior Ischemic Optic Neuropathy and Optic Neuritis.

    Science.gov (United States)

    Kim, Min Kyung; Kim, Ungsoo Samuel

    2016-08-01

    We evaluated fundus and fluorescein angiography (FAG) findings and characteristics that can help distinguish nonarteritic anterior ischemic optic neuropathy (NAION) from optic neuritis (ON). Twenty-three NAION patients and 17 ON with disc swelling patients were enrolled in this study. We performed fundus photography and FAG. The disc-swelling pattern, hyperemia grade, presence of splinter hemorrhages, cotton-wool spots, artery/vein ratio and degree of focal telangiectasia were investigated. The FAG findings for each patient were compared with respect to the following features: the pattern of disc leakage in the early phase, arteriovenous (artery/vein) transit time (second), and the presence and pattern of the filling delay. Cotton-wool spots, focal telangiectasia, and venous congestion were more common in the affected eyes of NAION patients. Upon FAG, 76.5% of the patients in the ON group exhibited normal choroidal circulation. However, 56.5% of patients in the NAION group demonstrated abnormal filling defects, such as peripapillary, generalized, or watershed zone filling delays. Fundus findings, including cotton-wool spots, focal telangiectasia, and venous congestion in the affected eye, may be clues that can be used to diagnose NAION. In addition, choroidal insufficiencies on FAG could be also helpful in differentiating NAION from ON.

  19. Color Fundus Photography, Optical Coherence Tomography, and Fluorescein Angiography in Diagnosing Polypoidal Choroidal Vasculopathy.

    Science.gov (United States)

    Chaikitmongkol, Voraporn; Khunsongkiet, Preeyanuch; Patikulsila, Direk; Ratanasukon, Mansing; Watanachai, Nawat; Jumroendararasame, Chaisiri; Mayerle, Catherine B; Han, Ian C; Chen, Connie J; Winaikosol, Pawara; Dejkriengkraikul, Chutikarn; Choovuthayakorn, Janejit; Kunavisarut, Paradee; Bressler, Neil M

    2018-05-10

    To determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis using color fundus photography (CFP), optical coherence tomography (OCT) and fundus fluorescein angiography (FFA) without indocyanine-green angiography (ICGA). Validity analysis. Treatment-naïve eyes with serous/serosanguinous maculopathy undergoing CFP, OCT, FFA and ICGA imaging before treatment at a university-hospital in Thailand (January 2013 to June 2015) were identified. Images of each subject were categorized into 4 sets (set A: CFP; set B: CFP+OCT; set C: CFP+FFA; set D: CFP+OCT+FFA). Six graders, 3 from Thailand (PCV endemic area) and 3 from U.S. (non-endemic area), individually reviewed each set (without ICG), and determined if the presumed diagnosis was PCV. In parallel, 2 other graders confirmed if each case had PCV or not using EVEREST criteria (including ICGA). Sensitivity and specificity of a PCV diagnosis with each set (without ICGA) were analyzed compared with diagnoses including ICGA. Of 119 study eyes (113 subjects, 57% male, mean age±SD 59.9±13.8), definite PCV diagnosis was 40.3%. Sensitivity of sets A, B, C, D: 0.63 (95%CI: 0.47-0.76), 0.83 (95%CI: 0.69-0.92), 0.54 (95%CI: 0.39-0.68), 0.67 (95%CI: 0.51-0.79). Specificity were 0.93 (95% CI: 0.84-0.97), 0.83 (95%CI: 0.72-0.91), 0.97 (95%CI: 0.89-0.99), 0.92 (95%CI: 0.82-0.97). Accuracies: 0.81 (95%CI: 0.73-0.88), 0.83 (95%CI: 0.76-0.90), 0.79 (95%CI: 0.73-0.87), 0.82 (95%CI: 0.74-0.88). Discrepancies between Thai and US graders existed through sets A, C, and D. These data suggest without ICGA, fundus photography combined with OCT provides high sensitivity and high specificity to diagnosis PCV; adding FFA does not improve accuracy. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Fundus autofluorescence in central serous chorioretinopathy:association with spectral-domain optical coherence tomography and fluorescein angiography

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2015-10-01

    Full Text Available AIM: To evaluate the correlation among changes in fundus autofluorescence (AF measured using infrared fundus AF (IR-AF and short-wave length fundus AF (SW-AF with changes in spectral-domain optical coherence tomography (SD-OCT and fluorescein angiography (FA in central serous chorioretinopathy (CSC.METHODS:Two hundred and twenty consecutive patients with CSC were included. In addition to AF, patients were assessed by means of SD-OCT and FA. Abnormalities in images of IR-AF, SW-AF, FA were analyzed and correlated with the corresponding outer retinal alterations in SD-OCT findings.RESULTS:Eyes with abnormalities on either IR-AF or SW-AF were found in 256 eyes (58.18%, among them 256 eyes (100% showed abnormal IR-AF, but SW-AF abnormalities were present only in 213 eyes (83.20%. The hypo-IR-AF corresponded to accumulation of sub-retinal liquid, collapse of retinal pigment epithelium (RPE or detachment of RPE with or without RPE leakage point in the corresponding area. The hyper-IR-AF corresponded to the area with loss of the ellipsoid portion of the inner segments and sub-sensory retinal deposits or focal melanogenesis under sensory retina. The hypo-SW-AF corresponded to accumulation of sub-retinal liquid or atrophy of RPE. The hyper-SW-AF associated with sub-sensory retinal deposits, detachment of RPE and focal melanogenesis.CONCLUSION:IR-AF was more sensitive than SW-AF and FA for identifying pathological abnormalities in CSC. The characteristics of IR-AF in CSC were attributable to the modification of melanin in the RPE. IR-AF should be used as a common diagnostic tool for identifying pathological lesion in CSC.KEYWORDS:central serous chorioretinopathy; fluorescein angiography; fundus autofluorescence; optical coherence tomography

  1. Agreement between optical coherence tomography and fundus fluorescein angiography in post-cataract surgery cystoid macular edema

    Directory of Open Access Journals (Sweden)

    Mitne Somaia

    2003-01-01

    Full Text Available PURPOSE: To evaluate the agreement between optical coherence tomography (OCT and fundus fluorescein angiography (FFA regarding the detection of cystoid macular edema (CME following cataract surgery. METHODS: Retrospective comparative observational series of 25 eyes with suspected CME. Patients with low visual acuity and alterations in fundus biomicroscopy after cataract surgery underwent OCT scanning followed by FFA on the same visit. The diagnosis of CME was established considering fluorescein leakage on FFA and retinal thickness and/or cystoid spaces and/or subretinal fluid on OCT. RESULTS: Twenty-five eyes of 25 patients were enrolled. Twenty-two eyes had similar results on both OCT and FFA, of which 15 eyes had CME and 7 eyes had no CME. Two eyes had CME detected only by FFA and one eye only by OCT. The agreement between the two examinations was good (Kappa = 0.7331; p=0.0001 with no tendency to have neither more positive nor negative findings (p=1.0. CONCLUSION: According to these preliminary data, OCT seems to be as effective as FFA to detect CME with a good agreement between the two techniques.

  2. Automated detection of leakage in fluorescein angiography images with application to malarial retinopathy.

    Science.gov (United States)

    Zhao, Yitian; MacCormick, Ian J C; Parry, David G; Leach, Sophie; Beare, Nicholas A V; Harding, Simon P; Zheng, Yalin

    2015-06-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage.

  3. Color Fundus Photography versus Fluorescein Angiography in Identification of the Macular Center and Zone in Retinopathy of Prematurity

    Science.gov (United States)

    Patel, Samir N.; Klufas, Michael A.; Ryan, Michael C.; Jonas, Karyn E.; Ostmo, Susan; Martinez-Castellanos, Maria Ana; Berrocal, Audina M.; Chiang, Michael F.; Chan, R.V. Paul

    2016-01-01

    Purpose To examine the utility of fluorescein angiography (FA) in identification of the macular center and the diagnosis of zone in patients with retinopathy of prematurity (ROP). Design Validity and reliability analysis of diagnostic tools Methods 32 sets (16 color fundus photographs; 16 color fundus photographs paired with the corresponding FA) of wide-angle retinal images obtained from 16 eyes of eight infants with ROP were compiled on a secure web site. 9 ROP experts (3 pediatric ophthalmologists; 6 vitreoretinal surgeons) participated in the study. For each image set, experts identified the macular center and provided a diagnosis of zone. Main Outcome Measures (1) Sensitivity and specificity of zone diagnosis (2) “Computer facilitated diagnosis of zone,” based on precise measurement of the macular center, optic disc center, and peripheral ROP. Results Computer facilitated diagnosis of zone agreed with the expert’s diagnosis of zone in 28/45 (62%) cases using color fundus photographs and in 31/45 (69%) cases using FA. Mean (95% CI) sensitivity for detection of zone I by experts as compared to a consensus reference standard diagnosis when interpreting the color fundus images alone versus interpreting the color fundus photographs and FA was 47% (35.3% – 59.3%) and 61.1% (48.9% – 72.4%), respectively, (t(9) ≥ (2.063), p = 0.073). Conclusions There is a marginally significant difference in zone diagnosis when using color fundus photographs compared to using color fundus photographs and the corresponding fluorescein angiograms. There is inconsistency between traditional zone diagnosis (based on ophthalmoscopic exam and image review) compared to a computer-facilitated diagnosis of zone. PMID:25637180

  4. Grading of Age-Related Macular Degeneration: Comparison between Color Fundus Photography, Fluorescein Angiography, and Spectral Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Nils F. Mokwa

    2013-01-01

    Full Text Available Purpose. To compare color fundus photography (FP, fluorescein angiography (FA, and spectral domain optical coherence tomography (SDOCT for the detection of age-related macular degeneration (AMD, choroidal neovascularisation (CNV, and CNV activity. Methods. FPs, FAs, and SDOCT volume scans from 120 eyes of 66 AMD and control patients were randomly collected. Control eyes were required to show no AMD, but other retinal pathology was allowed. The presence of drusen, pigmentary changes, CNV, and signs for CNV activity was independently analyzed for all imaging modalities. Results. AMD was diagnosed based on FP in 75 eyes. SDOCT and FA showed sensitivity (specificity of 89% (76% and 92% (82%, respectively. CNV was present on FA in 68 eyes. Sensitivity (specificity was 78% (100% for FP and 94% (98% for SDOCT. CNV activity was detected by SDOCT or FA in 60 eyes with an agreement in 46 eyes. Sensitivity was 88% for SDOCT and 88% for FA. FP showed sensitivity of 38% and specificity of 98%. Conclusions. CNV lesions and activity may be missed by FP alone, but FP may help identifying drusen and pigmentary changes. SDOCT is highly sensitive for the detection of AMD, CNV, and CNV activity; however, it cannot fully replace FA.

  5. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro

    OpenAIRE

    Dias, Lillian Abreu; Morizot, Eduardo H.

    2015-01-01

    ABSTRACTPurpose:To characterize multiple evanescent white dot syndrome (MEWDS)-like lesions as diagnosed by clinical exam and fluorescein angiography (FA) to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients’ information about the natural good course of this disease.Methods:A cross-sectional study including all FA performed from July 2006 to October 2012 (6,111...

  6. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro

    OpenAIRE

    Dias,Lillian Abreu; Morizot,Eduardo H.

    2015-01-01

    ABSTRACTPurpose:To characterize multiple evanescent white dot syndrome (MEWDS)-like lesions as diagnosed by clinical exam and fluorescein angiography (FA) to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients’ information about the natural good course of this disease.Methods:A cross-sectional study including all FA performed from July 2006 to October 2012 ...

  7. Macular laser photocoagulation guided by spectral-domain optical coherence tomography versus fluorescein angiography for diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Gallego-Pinazo R

    2011-05-01

    Full Text Available Roberto Gallego-Pinazo1,2, Ana Marina Suelves-Cogollos1, Rosa Dolz-Marco1, J Fernando Arevalo3, Salvador García-Delpech1, J Luis Mullor4, Manuel Díaz-Llopis1,2,51Department of Ophthalmology, Hospital Universitario La Fe, Valencia, Spain; 2Centro de Investigación Biomédica en Red de Enfermedades Raras, Valencia, Spain; 3Retina and Vitreous Service, Clinical Ophthalmology Center, Caracas, Venezuela; 4Unit of Experimental Ophthalmology, Hospital Universitario La Fe, Valencia, Spain; 5University of Valencia, Faculty of Medicine, Valencia, SpainBackground: The aim of this study was to compare the efficacy of spectral-domain optical coherence tomography (SD-OCT and fluorescein angiography (FA in the guidance of macular laser photocoagulation for diabetic macular edema.Methods: This was a prospective interventional clinical comparative pilot study. Forty eyes from 24 consecutive patients with diabetic macular edema were allocated to receive laser photocoagulation guided by SD-OCT or FA. Best-corrected visual acuity (BCVA, central macular thickness, and retinal volume were assessed at baseline and two months after treatment.Results: Subjects treated using FA-guided laser improved BCVA from the logarithm of the minimum angle of resolution (logMAR 0.52 ± 0.2 to 0.37 ± 0.2 (P < 0.001, and decreased mean central macular thickness from 397.25 ± 139.1 to 333.50 ± 105.7 µm (P < 0.001 and retinal volume from 12.61 ± 1.6 to 10.94 ± 1.4 mm3 (P < 0.001. Subjects treated using SD-OCT guided laser had improved BCVA from 0.48 ± 0.2 to 0.33 ± 0.2 logMAR (P < 0.001, and decreased mean central macular thickness from 425.90 ± 149.6 to 353.4 ± 140 µm (P < 0.001 and retinal volume from 12.38 ± 2.1 to 11.53 ± 1.1 mm3 (P < 0.001. No significant differences between the groups were found in two-month BCVA (P = 0.505, two-month central macular thickness (P = 0.660, or two-month retinal volume (P = 0.582.Conclusion: The short-term results of this pilot study

  8. Fluorescein-related extensive jaundice.

    Science.gov (United States)

    Kalkan, Asim; Turedi, Suleyman; Aydin, Ibrahim

    2015-03-01

    Fluorescein is a chemical dye frequently used in eye diseases to assess blood flow in the retina, choroid tissue, and iris. Although it has many known adverse effects, it has not previously been reported to lead to jaundice. The purpose of this case report was to emphasize that for patients presenting at the emergency department with jaundice symptoms, it should not be forgotten by emergency physicians that jaundice can develop after fluorescein angiography. Case: A 65-year-old woman presented at the emergency department with extensive jaundice that had developed on her entire body a few hours after fluorescein angiography applied because of vision impairment. The test results for all the diseases considered to cause jaundice were normal,and fluorescein-related jaundice was diagnosed. Conclusion: A detailed anamnesis should be taken when jaundice is seen in patients who have undergone fluorescein angiography, and it should not be forgotten that fluorescein dye is a rare cause of jaundice.

  9. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Lillian Abreu Dias

    2015-08-01

    Full Text Available ABSTRACTPurpose:To characterize multiple evanescent white dot syndrome (MEWDS-like lesions as diagnosed by clinical exam and fluorescein angiography (FA to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients’ information about the natural good course of this disease.Methods:A cross-sectional study including all FA performed from July 2006 to October 2012 (6,111 exams analyzed in patients at our ophthalmic emergency department, with analysis of the different angiographic aspects of the MEWDS-diagnosed cases.Results:Among the 6,111 angiographies analyzed, 15 MEWDS cases were detected; the patients ranged in age from 13 to 42 years old, and the male/female ratio was 60% to 40% (nine male and six female. The most common FA aspects included hyperfluorescent dots, dots and spots in the retinal mid-periphery, and foveal granularity in 46% of the cases.Conclusions:MEWDS has a good prognosis, with spontaneous involution, which makes it difficult to diagnose because of the delayed access to ophthalmological assistance, in special FA examination, which highlights the lesions. This study was possible due to the quick access facility at a private ophthalmic emergency department and examination by an experienced ophthalmologist, along with complementary diagnosis by FA and better perception of the patients, thus ensuring good prognosis.

  10. Evaluation of MEWDS-like lesions with fluorescein angiography and its frequency at an ophthalmic emergency department in Rio de Janeiro.

    Science.gov (United States)

    Dias, Lillian Abreu; Morizot, Eduardo H

    2015-01-01

    To characterize multiple evanescent white dot syndrome (MEWDS)-like lesions as diagnosed by clinical exam and fluorescein angiography (FA) to build an epidemiological profile of this disease and highlight the most common angiographical aspects. It is important to emphasize the existence of this syndrome and improve patients' information about the natural good course of this disease. A cross-sectional study including all FA performed from July 2006 to October 2012 (6,111 exams analyzed) in patients at our ophthalmic emergency department, with analysis of the different angiographic aspects of the MEWDS-diagnosed cases. Among the 6,111 angiographies analyzed, 15 MEWDS cases were detected; the patients ranged in age from 13 to 42 years old, and the male/female ratio was 60% to 40% (nine male and six female). The most common FA aspects included hyperfluorescent dots, dots and spots in the retinal mid-periphery, and foveal granularity in 46% of the cases. MEWDS has a good prognosis, with spontaneous involution, which makes it difficult to diagnose because of the delayed access to ophthalmological assistance, in special FA examination, which highlights the lesions. This study was possible due to the quick access facility at a private ophthalmic emergency department and examination by an experienced ophthalmologist, along with complementary diagnosis by FA and better perception of the patients, thus ensuring good prognosis.

  11. Relationships among Ocular Blood Flow Shown by Laser Speckle Flowgraphy, Retinal Arteriosclerotic Change, and Chorioretinal Circulation Time Obtained by Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Hironori Osamura

    2017-01-01

    Full Text Available Purpose. To determine the correlations among the mean blur rate (MBR in the optic nerve head (ONH shown by laser speckle flowgraphy (LSFG, retinal arteriosclerosis, and the circulation time obtained by fluorescein angiography (FA. Method. We evaluated 118 patients and assessed their time of choroidal flush, arm-to-retina time, and early and late phases of retinal circulation time (RT: sec obtained by FA. The severity of retinal arteriosclerosis was classified according to the Scheie classification. The MBR values throughout the ONH (MBR-A, in the tissue (MBR-T, and in the vessels (MBR-V were analyzed. Results. Patients with retinal vein occlusion (RVO showed prolonged early and late phases of RT compared to other ocular diseases. Single and multiple regression analyses showed that the MBR-V and Scheie classification were significantly associated with both the choroidal flush and arm-to-retina times. The incidences of RVO and MVR-V were significantly associated with the early phase of RT, and the incidences of RVO, MBR-V, Scheie classification, and gender were revealed to be factors independently contributing to the late phase of RT. Conclusion. MBR-V in the ONH and retinal arteriosclerosis are important contributing factors for the circulation time of each stage obtained by FA.

  12. Simultaneous Fluorescein Angiography and Spectral Domain Optical Coherence Tomography Correlate Retinal Thickness Changes to Vascular Abnormalities in an In Vivo Mouse Model of Retinopathy of Prematurity

    Directory of Open Access Journals (Sweden)

    Olachi J. Mezu-Ndubuisi

    2017-01-01

    Full Text Available Background. Retinopathy of prematurity (ROP is a condition of abnormal retinal vascular development (RVD in premature infants. Fluorescein angiography (FA has depicted phases (early, mid, late, and mature of RVD in oxygen-induced retinopathy (OIR mice. We sought to establish the relationship between retinal structural and vascular changes using simultaneous FA and spectral domain optical coherence tomography (SD-OCT. Method. 63 mice were exposed to 77% oxygen at postnatal day 7 (P7 for 5 days, while 63 mice remained in room air (RA. Total retinal thickness (TRT, inner retinal thickness (IRT, and outer retinal thickness (ORT were calculated at early (P19, mid (P24, late (P32, and mature (P47 phases of RVD. Results. TRT was reduced in OIR (162.66 ± 17.75 μm, n=13 compared to RA mice at P19 (197.57 ± 3.49 μm, n=14, P24, P32, and P49 (P0.05. IRT was reduced in OIR (71.60 ± 17.14 μm compared to RA (103.07 ± 3.47 μm mice at P19 and all ages (P<0.0001. Conclusion. We have shown the spatial and temporal relationship between retinal structure and vascular development in OIR. Significant inner retinal thinning in OIR mice persisted despite revascularization of the capillary network; further studies will elucidate its functional implications in ROP.

  13. Fluorescein angiogram in diabetic dogs

    International Nuclear Information System (INIS)

    Ono, K.; Yasuda, K.; Iwata, H.; Nakayama, H.; Hasegawa, A.; Tomoda, I.

    1986-01-01

    Fluorescein angiography was carried out see retinal vascular changes of the ocular fundus in 4 spontaneously occurring diabetic dogs. In all 4 cases, several hypofluorescent areas were determined to be filling defects of the retinal capillary bed of the tapetal fundi during the arteriovenous phase. Around these hypofluorescent areas, many dots of hyperfluorescence were also observed to be microaneurysms. However, no leaking of fluorescein was detected during angiography. These findings of 4 diabetic dogs were similar to those reported in man with non-proliferative diabetic retinopathy

  14. Fundus fluorescein angiography in the early diagnosis of diabetic retinopathy significance%眼底荧光血管造影对早期诊断糖尿病性视网膜病变的意义

    Institute of Scientific and Technical Information of China (English)

    王霞; 裴承华; 丁爱东

    2014-01-01

    ObjectiveTo explore the Fundus fluorescein angiography in the early diagnosis of diabetic retinopathy significance.Methods300 cases (273 eyes) diabetic patients clinical data were collectes from 2010 December to 2012 December,and all patients were checked with ophthalmoscope and fundus fluorescein angiography two checking methods.Results153 cases were checked by the ophthalmoscopic lesions number,lesions was 56.05%;251 cases were detected by FFA lesions,which followed by fundus fluorescein angiography,lesions was 91.94%.The diagnosis of fundus fluorescein angiography of the correct rate had a higher Correct rate,the difference was statistically significant between the two groups (P<0.05).Non proliferative diabetic retinopathy had 55 cases by FFA lesions,accounting for 21.91% disease variables;preproliferative diabetic retinopathy had 73 cases,accounting for 29.08%;proliferative diabetic retinopathy had 65 cases,accounting for 25.91%;diabetic macularlesions had 35 cases,accounting for 13.94%;diabetic papillopathy had 23 cases,accounting for 9.16%.Conclusion Early diabetic retinopathy fluorescein angiography can be found on thelens cannot make diagnosis.%目的:探讨眼底荧光血管造影对早期诊断糖尿病性视网膜病变的意义。方法选取2010年12月~2012年12月300例(273只眼)糖尿病患者的临床资料,所有患者皆用检眼镜和荧光素眼底血管造影两种检查方法。结果采用检眼镜检出病变数153例,病变率为56.05%;后经荧光素眼底血管造影检查,发现FFA检出病变数251例,病变率为91.94%,荧光素眼底血管造影的诊断正确率较高,两组比较,差异具有统计学意义(P<0.05)。FFA检查病变种类主要包括非增生性糖尿病性视网膜病变55例,占病变数的21.91%;增生前糖尿病性视网膜病变73例,占29.08%;增生型糖尿病性视网膜病变;65例,占25.91%;糖尿病性黄斑病变35例,占13.94%;糖

  15. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  16. Vogt-小柳-原田综合征的眼底荧光血管造影分析%Study and analysis of Vogt-Koyanagi-Harada syndrome by fundus fluorescein angiography

    Institute of Scientific and Technical Information of China (English)

    曹芳

    2014-01-01

    目的:探讨 Vogt-小柳-原田综合征( Vogt-Koyanagi-Harada syndrome, VKHS )的眼底荧光血管造影( fundus fluorescein angiography,FFA)的表现及其临床意义。  方法:对VKHS患者16例30眼进行眼部详细检查,并行眼底彩色照相和FFA等检查。  结果:Vogt-小柳-原田综合征葡萄膜炎期的眼底表现为3种类型,脉络膜炎性渗出及渗出性视网膜脱离是视力损害的主要原因,而视盘水肿充血对视力损害较轻,且恢复较好。  结论:FFA的特征性表现对该病早期具有重要诊断意义。%AIM:To study cilncial features and significance of Vogt-Koyanagi - Harada syndrome ( VKHS ) by fundus fluorescein angiography ( FFA) . METHODS: All 16 cases ( 30 eyes ) of VKHS were underwent by detailed paysical examination. Then took colour photographs and examined by FFA. RESULTS:Uveitis stage of VKHS could be classified into three kinds of fundus appearances. The vision damage was mainly associated to exudation of choroidal vessel and exsudative retinal detachment rather than edema of optic disc which could achieve a better recovery. CONCLUSION: FFA is an important and valuable examination to diagnose the VKHS forepart.

  17. 眼底荧光血管造影诊断早期糖尿病性视网膜病变%Fluorescein angiography in diagnosis of early diabetic retinopathy

    Institute of Scientific and Technical Information of China (English)

    李敏

    2013-01-01

    Objective: To assess the value of fundus fluorescence angiogiaphy(FFA) in diagnostic of early diabetic retinopathy (DR) that had failed to be detected by ophthalenosope. Methods: One hundred and one patients ( 202 eyes) with non-insulin-dependent diabetes mellitus who had been proved to have no DR by ophthalenosope received FFA examination. Results: Forty-five patients (90 eyes) were found to have early DR by FFA. The lesions included capillaries lump, capillary non-perfusion, capillary fluorescence leakage, telangiectasis and macular edema. Conclusions: Fundus fluorecein angiography can detect diabetic retinopathy earlier than ophthalenosope.%目的:评价眼底荧光血管造影(fundus fluorescein angiography,FFA)诊断在检眼镜下未发现病变的早期糖尿病性视网膜病变(diabetic retinopathy,DR)的价值.方法:对101例(202眼)检眼镜下未发现DR的2型糖尿病患者进行FFA检查.结果:45例(90眼)FFA检查可见不同程度的早期DR,病变包括微血管瘤、毛细血管无灌注区、毛细血管荧光渗漏、毛细血管扩张及黄斑水肿.结论:FFA能更早发现早期DR.

  18. Accidental intra-arterial injection of fluorescein dye.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-12-01

    During fluorescein angiography, sodium fluorescein dye intended for intravenous use was inadvertently injected into an artery in the antecubital fossa. An immediate and dramatic orange discoloration of the skin distal to the injection combined with intense burning pain of the right forearm and hand were noted. The patient was treated with ice packs and analgesics. The fluorescein angiogram showed a delayed arm to eye circulation time, but was of normal quality. There were no long-term complications.

  19. Preparo do oftalmologista para o tratamento das reações adversas na retinografia fluoresceínica Evaluation of knowledge of the ophthalmologists regarding for the treatment of adverse reactions in fluorescein angiography

    Directory of Open Access Journals (Sweden)

    Rodrigo Pessoa Cavalcanti Lira

    2005-06-01

    Full Text Available OBJETIVOS: Avaliar a estrutura das clínicas que realizam retinografia fluoresceínica em Pernambuco e, por meio de questionário, avaliar o preparo do oftalmologista para contornar reações adversas relativas ao exame e determinar se o tempo de conclusão do curso de especialização influencia nos resultados. MÉTODOS: Foi realizada entrevista com os 18 médicos nas dez clínicas que realizam este exame. O questionário era de múltipla escolha com dez questões. Versava sobre aspectos das reações adversas. RESULTADOS: Um médico recusou-se a participar e foi excluído. Entre os demais, quinze (88,2% possuíam o título de especialista. Todas as clínicas estavam bem aparelhadas em relação à estrutura básica de equipamentos e medicações para o atendimento inicial de reações adversas. Metade das clínicas (cinco realizava o exame com a presença de um anestesista na sala e a outra metade dispunha de um anestesista de sobreaviso dentro da instituição. O número de acertos obtidos pelos médicos variou de 3 a 8, com média de 5,2±1,6 acertos. Apenas quatro (23,6% médicos obtiveram nota igual ou superior a sete acertos. Médicos com até cinco anos de conclusão do curso de especialização obtiveram melhor desempenho no questionário (pPURPOSES: To evaluate the emergency resources of the clinics that perform fluorescein angiography in Pernambuco and, through a short multiple-choice questionnaire, to evaluate the ophthalmologists' performance to treat adverse reactions to contrast injection and to determine if the time after completing the specialization course in Ophthalmology influences in the results. METHODS: An interview with the eighteen ophthalmologists of the ten clinics where this examination is performed was made. The multiple-choice questionnaire had ten questions with five options each and only one correct answer. This questionnaire was about adverse reactions to fluorescein injection. RESULTS: One physician refused to

  20. Sympathetic ophthalmia - histopathological correlation with fluorescein and indocyanine green angiography: case report Oftalmia simpática - correlação da histopatologia com a angiografia por fluoresceína e indocianina verde: relato de caso

    Directory of Open Access Journals (Sweden)

    Antônio Marcelo Barbante Casella

    2008-12-01

    Full Text Available This study correlates fluorescein angiography (FA and indocyanine green angiography (ICGA to histopathologic findings in a patient with sympathetic ophtalmia. A male with a perforated trauma in right eye presented after two months a decrease in visual acuity of the left eye. FA and ICGA were performed and the images were correlated with the histopathologic findings of the enucleated eye; FA showed background areas of homogeneous hypofluorescence in the arterial and venous phases, as well as areas of granular progressive hyperfluorescence and leakage from the optic disc. ICGA showed areas of hypofluorescence in the early and intermediate phases of the examination, which persisted until the late phase. During the early phase, there was also diffuse hypofluorescence caused by blockage that allowed observation of areas of partial choroidal circulation. The histopathology of the enucleated right eye showed diffuse choriocapillaris edema and inflammation of the choroids, focal areas of hyperplasia of the retinal pigment epithelium (RPE as well as foci of epithelioid cells located between the choroid and the RPE. Furthermore, lymphocytic infiltration of the episcleral veins and retinal detachment were present. The hyperfluorescence observed on FA was correlated to retinal detachment and optic nerve inflammation. The hypofluorescence noted on FA and ICGA corresponded to the presence of blocking inflammatory cells (Dalen-Fuchs-like nodules and to diffuse choriocapillaris edema.O objetivo deste relato de caso foi correlacionar achados da histopatologia com a angiografia por fluoresceína (AF e por indocianina verde (AIV em um paciente com oftalmia simpática. Após dois meses de trauma perfurante no olho direito, o paciente apresentou baixa acuidade visual no olho esquerdo (OE. A AF do OE mostrou áreas de hipofluorescência homogênea na fase arterial e venosa, áreas de progressiva hiperfluorescência granular e vazamento do disco. A AIV mostrou

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  2. Retcam fluorescein gonioangiography: a new modality for early detection of angle neovascularization in diabetic retinopathy.

    Science.gov (United States)

    Azad, Rajvardhan; Arora, Tarun; Sihota, Ramanjit; Chandra, Parijat; Mahajan, Deepankur; Sain, Siddarth; Sharma, Yograj

    2013-10-01

    To evaluate the role of Retcam fluorescein gonioangiography in detecting neovascularization of the angle and correlate the same with gonioscopy in diabetic retinopathy. One hundred and fifty eyes of 150 patients (25 each of mild, moderate, severe, very severe nonproliferative diabetic retinopathy (NPDR) proliferative diabetic retinopathy (PDR); and PDR with high-risk characteristics) were recruited. They underwent complete ocular examination including applanation tonometry, gonioscopy, Retcam fluorescein gonioangiography, and fundus fluorescein angiography. Using Retcam fluorescein gonioangiography, of 150 eyes neovascularization of the angle was detected in 37 eyes (24.66%) compared with 22 eyes (14.66%) on gonioscopy (P = 0.04). Small newly formed vessels were evident only with Retcam fluorescein gonioangiography. In 10 of 50 patients (20%) with severe/very severe NPDR, angle neovascularization was appreciable on Retcam fluorescein angiography compared with 5 patients (10%) on gonioscopy. Similarly, 25 of 50 patients (50%) with PDR/PDR with high-risk characteristics had neovascularization of the angle on Retcam gonioangiography compared with 17 (34%) on gonioscopy. Retcam fluorescein gonioangiography is a novel technique for early detection of angle neovascularization in diabetic retinopathy and hence preventing progression to neovascular glaucoma. The objective nature of this test helps in precise decision making compared with gonioscopy for early intervention especially in cases of pre-PDR.

  3. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  7. Fluorescence angiography in retinal tumours

    International Nuclear Information System (INIS)

    Fuhrmann, M.

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed. (author)

  8. Fluorescence angiography in retinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Fuhrmann, M [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed.

  9. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    International Nuclear Information System (INIS)

    Krzywicki, S.; Slankiewicz, A.; Jablonska-Budaj, U.

    1980-01-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population. (author)

  10. Early diagnosis of retinopathy in juvenile diabetes by fluorescence angiography

    Energy Technology Data Exchange (ETDEWEB)

    Krzywicki, S; Slankiewicz, A; Jablonska-Budaj, U [Szpital-Pomnik Centrum Zdrowia Dziecka, Warsaw (Poland). Zespol Problemowy Okulistiky

    1980-09-01

    The authors defined the usefulness of the fluorescein angiography of the retina and choroid in the early stage diagnosis of diabetic retinopathy in children comparing its results to the traditional ophthalmoscopy. Examination involved 50 children from 4 to 18 (30 boys and 20 girls) on insulin treatment. The duration of the disease was 1 to 14 years (average 7.36 years). Ophthalmoscopy showed pathological changes in 24% of the children. The fluorescein angiography visualized more microaneurysms compared to ophthalmoscopy and showed them sometimes in the eyes where they had not been found in eye fundus studies. By means of angiography the early and advanced stages of vascular complications were found in 64% of patients. Comparing to ophthalmoscopy a 40% increase was noted. Fluorescein angiography can lead to the decrease in the number of patients with markedly impaired visual acuity and cases of blindness in the diabetic population.

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. Angiography uses ... has narrowed the arteries to the legs and help prepare for endovascular intervention or surgery. detect disease ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ...

  19. Avaliação da função macular por eletrorretinografia focal e por angiofluoresceinografia em pacientes com degeneração macular relacionada à idade neovascular submetidos à terapia fotodinâmica com verteporfina Evaluation of the macular function by focal electroretinography and by fluorescein angiography in patients with neovascular age-related macular degeneration submitted to verteporfin photodynamic therapy

    Directory of Open Access Journals (Sweden)

    Akiyoshi Oshima

    2009-02-01

    Full Text Available OBJETIVOS: Avaliar a função macular por eletrorretinografia focal e angiofluoresceinografia em pacientes com degeneração macular relacionada à idade neovascular submetidos à terapia fotodinâmica com verteporfina. MÉTODOS: Estudo prospectivo incluindo 22 pacientes (12 homens com degeneração macular relacionada à idade e lesão neovascular coroídea subfoveal predominantemente clássica, não consecutivos, tratados com terapia fotodinâmica com verteporfina padrão e acompanhados por um período de 12 meses. A acuidade visual melhor corrigida foi medida utilizando tabela ETDRS, as alterações das lesões foram avaliadas pela angiofluoresceinografia e a função dos cones foram obtidas pela eletrorretinografia focal na visita inicial e nas subsequentes a cada três meses. RESULTADOS: Todos os pacientes completaram as visitas programadas. Após uma média de 3,5 sessões por paciente, a variação da acuidade visual melhor corrigida não foi significante no decorrer do estudo. Em 50% dos pacientes a variação da acuidade visual melhor corrigida foi >1 linha. Ao final do estudo observou-se ausência de vazamento em 86% dos pacientes. A média da amplitude e latência do ERG focal na visita inicial foram de, respectivamente, 194,88 nV e 29,19 ms e as variações no decorrer do estudo não foram significantes. CONCLUSÕES: Não foram encontradas diferenças na amplitude e latência do eletrorretinografia focal após um período de 9 meses. A acuidade visual melhor corrigida não sofreu variações significativas ao longo dos 12 meses. A lesão foi significativamente reduzida ao longo do tempo e houve uma correlação negativa entre a amplitude e a acuidade visual melhor corrigida.PURPOSE: To evaluate macular function by focal electroretinography and fluorescein angiography (FA in patients with neovascular age-related macular degeneration submitted to verteporfin photodynamic therapy (VPT. METHODS: Prospective study involving 22 patients

  20. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  1. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  2. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... to your primary care or referring physician , who will discuss the results with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... a tendency to bleed. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... accurate pictures of the blood vessels and may eliminate the need for surgery. Tell your doctor if ... are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If surgery remains necessary, ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... congenital abnormalities in blood vessels, especially arteries in children (e.g., malformations in the heart or other ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ... you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... serious allergic reaction to contrast materials that contain iodine is extremely rare, and radiology departments are well- ... having a reaction to contrast materials that contain iodine. If angiography is essential, a variety of methods ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... and treat medical conditions. Angiography uses one of three imaging technologies and, ...

  18. Fluorescein Derivatives in Intravital Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Michael S. Roberts

    2013-08-01

    Full Text Available Intravital fluorescence microscopy enables the direct imaging of fluorophores in vivo and advanced techniques such as fluorescence lifetime imaging (FLIM enable the simultaneous detection of multiple fluorophores. Consequently, it is now possible to record distribution and metabolism of a chemical in vivo and to optimise the delivery of fluorophores in vivo. Recent clinical applications with fluorescein and other intravital fluorescent stains have occurred in neurosurgery, dermatology [including photodynamic therapy (PDT] and endomicroscopy. Potential uses have been identified in periodontal disease, skin graft and cancer surgery. Animal studies have demonstrated that diseased tissue can be specifically stained with fluorophore conjugates. This review focuses on the fluorescein derived fluorophores in common clinical use and provides examples of novel applications from studies in tissue samples.

  19. Fluorescein-labeled stable neurotensin derivatives.

    Science.gov (United States)

    Maes, Veronique; Hultsch, Christina; Kohl, Suzann; Bergmann, Ralf; Hanke, Thomas; Tourwé, Dirk

    2006-08-01

    Neurotensin(8-13) analogs containing a glycine or 5-aminovaleroyl spacer were labeled with fluorescein through formation of an N-terminal thiourea function. The receptor binding was measured in HT-29 cell cultures and showed a substantial decrease in affinity, especially for the metabolically stabilized [MeArg(9), Tle(11)] analog. Using fluorescence microscopy, the internalization of the fluorescent neurotensin analogs into HT-29 cells was observed. Copyright (c) 2006 European Peptide Society and John Wiley & Sons, Ltd.

  20. Ultra-wide-field angiography improves the detection and classification of diabetic retinopathy.

    Science.gov (United States)

    Wessel, Matthew M; Aaker, Grant D; Parlitsis, George; Cho, Minhee; D'Amico, Donald J; Kiss, Szilárd

    2012-04-01

    To evaluate patients with diabetic retinopathy using ultra-wide-field fluorescein angiography and to compare the visualized retinal pathology with that seen on an overly of conventional 7 standard field (7SF) imaging. Two hundred and eighteen eyes of 118 diabetic patients who underwent diagnostic fluorescein angiography using the Optos Optomap Panoramic 200A imaging system were included. The visualized area of the retina, retinal nonperfusion, retinal neovascularization, and panretinal photocoagulation were quantified by two independent masked graders. The respective areas identified on the ultra-wide-field fluorescein angiography image were compared with an overly of a modified 7SF image as outlined in the Early Treatment Diabetic Retinopathy Study. Ultra-wide-field fluorescein angiograms imaging, on average, demonstrated 3.2 times more total retinal surface area than 7SF. When compared with 7SF, ultra-wide-field fluorescein angiography showed 3.9 times more nonperfusion (P diabetic retinopathy. Improved retinal visualization may alter the classification of diabetic retinopathy and may therefore influence follow-up and treatment of these patients.

  1. 77 FR 23269 - Determination That FUNDUSCEIN-25 (fluorescein sodium injection), 25%, and AK-FLUOR (fluorescein...

    Science.gov (United States)

    2012-04-18

    ... marketing for reasons other than safety or effectiveness. ANDAs that refer to FUNDUSCEIN-25 (fluorescein...), 25%, Were Not Withdrawn From Sale for Reasons of Safety or Effectiveness AGENCY: Food and Drug... withdrawn from sale for reasons of safety or effectiveness. This determination will allow FDA to approve...

  2. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  3. [Endoscopic endonasal detection of cerebrospinal fluid leakage with topical fluorescein].

    Science.gov (United States)

    Sato, Taku; Kishida, Yugo; Watanabe, Tadashi; Tani, Akiko; Tada, Yasuhiro; Tamura, Takamitsu; Ichikawa, Masahiro; Sakuma, Jun; Omori, Koichi; Saito, Kiyoshi

    2013-08-01

    We evaluated the effectiveness of intraoperative topical application of fluorescein to detect the leakage point of cerebrospinal fluid(CSF)rhinorrhea. Three patients with CSF rhinorrhea were treated with an endoscopic endonasal technique. Ten percent fluorescein was topically used for intraoperative localization of the leak site. A change of the fluorescein color from brown to green due to dilation of CSF were recognized as evidence of CSF rhinorrhea. We repeated the procedure to detect any small defects. All CSF rhinorrheas were successfully repaired by this endoscopic endonasal approach. Topical application of fluorescein is simple and sensitive for identifying intraoperative CSF rhinorrhea.

  4. MRI angiography

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriiaux, D.; struyven, J.; Segebarth, C.

    1989-01-01

    In MRI angiography two basis images are measured which only differ by the signal intensity of the flowing blood in the vessels. Subtraction of these two images produces a high contrast-to-noise representation of the vessels. Contrast between stationary tissues and flowing blood is changed, for one image compared to the second one, using a selective modification of the phase of the signal from the flowing blood, and/or using a selective modification of its longitudinal magnetization: The macroscopic spin motions along the selection and the measurement gradient directions affect the phase of the nuclear signal; assuming constant velocity, the phase is proportional to the velocity and to the first moment of the gradient waveforms applied. This work concentrates on the generarion of MRI angiograms, following a phase-based approach, of the carotid bifurcation and of different intracranical regions including the carotid syphon and the circle of Willis. (author). 21 refs.; 3 figs

  5. Radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Klotz, E

    1983-12-27

    RNA of common and internal carotid arteries as well as main cerebral arteries is the first component of cerebral serial scintigraphy. It should be the first diagnostic step in suspected cerebrovascular disease. In contrast to computed tomography RNA gives valuable information about cerebrovascular processes without morphological defects. RNA is superior of Doppler sonography in the evaluation of intracranial vascular disease. The simple and non-invasive RNA of the kidneys should be performed after renal transplantation (i.e. differential diagnosis of acute rejection and acute tubular necrosis), in suspected renal artery stenosis, renal infarction or in arterio-venous malformation of the kidneys. RNA is valuable in suspected occlusion of the abdominal aorta (infra- or suprarenal), aortic aneurysm or in stenosis of arteries in the pelvis or thighs. Postoperative controls can be carried out as often as desired. However, it cannot replace contrast angiography if vascular reconstruction is planned.

  6. Fluorescein isothiocyanate: Molecular characterization by theoretical calculations

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, Jordi [Departament de Quimica, Escola Politecnica Superior, Universitat de Lleida, c/Jaume II No 69, Lleida E-25001 (Spain); Jacquemin, Denis [Laboratoire de Chimie Theorique Appliquee, Facultes Universitaires Notre-Dame de la Paix, rue de Bruxelles, 61, B-5000 Namur (Belgium)], E-mail: denis.jacquemin@fundp.ac.be; Perpete, Eric A. [Laboratoire de Chimie Theorique Appliquee, Facultes Universitaires Notre-Dame de la Paix, rue de Bruxelles, 61, B-5000 Namur (Belgium); Aleman, Carlos [Departament d' Enginyeria Quimica, E. T. S. d' Enginyeria Industrial de Barcelona, Universitat Politecnica de Catalunya, Diagonal 647, Barcelona E-08028 (Spain)], E-mail: carlos.aleman@upc.edu

    2008-12-10

    Quantum mechanical calculations have been used to investigate the conformation, molecular geometry, basicity and spectroscopic properties of fluorescein isothiocyanate in both the gas-phase and aqueous solution. Specifically, calculations have been performed considering the neutral, monoanionic and dianionic forms of this important fluorescent compound. Results reveal that for the neutral form multiple conformational states are possible, all them with significant contributions, and the stability of the different conformers is similar in the gas-phase and aqueous solution. Calculation of the excitation energies revealed that spectroscopic properties are very sensitive to the relaxation effect in solution. A good agreement has been reached obtained between the experimental and theoretical values derived from time-dependent density functional theory methods for the neutral form, whereas for charged species the calculations fail to accurately reproduce the measured trends.

  7. The conservative behaviour of fluorescein | Smith | Water SA

    African Journals Online (AJOL)

    Failure to account for fluorescein absorbance changes with pH may be responsible for some of the apparent non-conservative behaviour of this easily detectable tracer compound. While it is possible to calculate an accurate absorptivity value for fluorescein at every pH, this calculation is not necessary if the sample pH is ...

  8. MR angiography

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Ross, J.S.

    1991-01-01

    This paper reports on preliminary research and recent clinical experience which indicates that MR angiography can play a role in routine scanning by providing useful information regarding the anatomy of the cerebral circulation. Used in conjunction with conventional spin-echo studies it may improve the overall sensitivity and specificity of MRI in a cost-effective fashion. It does not, however, replace conventional arteriography at this time for either extracranial or intracranial disease. The use of intravascular contrast agents with new fast-scan techniques also provides dynamic information regarding tissue perfusion in a fashion analogous to that of xenon CT. While this work is preliminary, and the exact agents and mathematical models have yet to be defined, the ability to perform parenchymal, angiographic, and physiologic imaging at a single setting is potentially very powerful. Clearly, the role of MR flow techniques deserves further investigation into possible technical refinements, so that accuracy relative to other diagnostic studies and impact upon patient management can be assessed in a meaningful way

  9. Microembolism after cerebral angiography

    International Nuclear Information System (INIS)

    Manaka, Hiroshi; Sakai, Hideki; Nagata, Izumi

    2000-01-01

    Acute microemboli are detected more precisely with the recently developed diffusion-weighted MR imaging (DWI). We happened to obtain 24 DWIs after 350 diagnostic cerebral angiographies in 1999. DWIs after cerebral angiographies showed bright lesions in 7 patients (28%), of whom 6 had no neurological symptoms after cerebral angiography. Seven of the 24 patients had risk factors for arteriosclerosis. Only one patient had embolic events due to angiography. Microemboli related to cerebral angiographies are inevitable in some patients. Most are silent, however, we should investigate the cause of microemboli and should make cerebral angiography safer. (author)

  10. Angiography in angiology

    International Nuclear Information System (INIS)

    Zeitler, E.; Grosse-Vorholt, R.

    1980-01-01

    A review is given of recent developments in angiography including advances in the equipment, in the technique and in image processing. Indications for and interpretation of angiography are discussed and angiographic-therapeutic procedures are considered. (C.F.)

  11. Optical Coherence Tomography Angiography in Retinal Diseases.

    Science.gov (United States)

    Chalam, K V; Sambhav, Kumar

    2016-01-01

    Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  12. Blunt ocular trauma at the posterior pole in optical coherence tomography and fluorescein angiography

    International Nuclear Information System (INIS)

    Meyer, C.H.; Eter, N.; Mennel, S.; Kroll, P.

    2007-01-01

    Blunt ocular trauma at the posterior pole may involve a variety of retinal structures. We examined the most frequent retinal trauma (choroidal folds, commotion retinae, choroidal rupture, valsalva retinopathy, PPE-tears, Purtscher's Retinopathy etc.) by optical coherence tomography (OCT). The damaged pre-, intra- or subretinal structures were clearly visible. The OCT is during acute and chronic phases of different traumatic events an important diagnostic tool. (author) [de

  13. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  14. MR-angiography

    International Nuclear Information System (INIS)

    Seiderer, M.

    1989-01-01

    Three categories of MRI techniques for vascular imaging are discussed: 2d-angiography using rephasing and dephasing pulse sequences and slice selective imaging; 3d-angiography using rehpasing and dephasing pulse sequences and fas 3d-imaging techniques; 3d-angiography using signal intensity modulation caused by pre- and post-contrast data acquisition (e.g. Gadolinium-DTPA) in combination with fast 3d-imaging (only one type of pulse sequence). (H.W.). 6 figs

  15. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  16. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    Science.gov (United States)

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  17. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  18. Optical Coherence Tomography Angiography of Retinal Cavernous Hemangioma.

    Science.gov (United States)

    Pierro, Luisa; Marchese, Alessandro; Gagliardi, Marco; Bandello, Francesco

    2017-08-01

    Retinal cavernous hemangioma is a rare, benign, retinal tumor characterized by angiomatous proliferation of vessels within the inner retina or the optic disc.1 Here we report a case of retinal cavernous hemangioma on the margin of the optic disc in the right eye of a 61-year-old asymptomatic female. The lesion was studied with multimodal imaging which included structural optical coherence tomography, fluorescein angiography, blue fundus auto-fluorescence, optical coherence tomography angiography (OCTA) (DRI OCT Triton; Topcon, Tokyo, Japan) and visual field examination. Blood circulation inside retinal cavernous hemangioma lesion is typically low-stagnant.2 However, OCTA demonstrated blood flow inside the lesion, illustrating its vascular circulation.3 Visual field was within the normal limits, except from a slight enlargement of the blind spot. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:684-685.]. Copyright 2017, SLACK Incorporated.

  19. [Indocyanine green angiography in "multiple evanescent white dot syndrome" (MEWDS)].

    Science.gov (United States)

    Desarnaulds, A B; Borruat, F X; Herbort, C P; de Courten, C

    1998-05-01

    Multiple evanescent white dot syndrome (MEWDS) is a benign acquired chorioretinal disorder occurring mostly in young adults. Its pathophysiology is unknown. To describe the results of indocyanine green angiography (ICGA) in MEWDS. Four patients with MEWDS were investigated by ICGA. In all cases, ICGA revealed numerous choroidal hypofluorescent lesions that largely outnumbered the lesions visible with either fundoscopy or fluorescein angiography. Three cases showed a blind spot enlargement on perimetry associated with the presence of a large peripapillary hypofluorescent zone on ICGA. Three cases showed macular granularity on fundoscopy correlating with a significant subfoveal hypfluorescent lesion on ICGA. Evolution was always favorable with disappearance of the hypofluorescent choroidal lesions. Our results confirm that MEWDS is primarily a choroidal disorder. The blind spot enlargement and the macular granularity, frequently detected in MEWDS, result from larger peripapillary and subfoveal choroidal lesions.

  20. Italian multicentre study on intrathecal fluorescein for craniosinusal fistulae.

    Science.gov (United States)

    Felisati, G; Bianchi, A; Lozza, P; Portaleone, S

    2008-08-01

    Cerebrospinal fluid leak (CSF), clinical sign of a dural lesion of the skull base, is a relatively rare event that can present with a variety of symptoms. Every craniosinus fistula should be considered a serious, potentially life-threatening situation (even those cases with hidden CSF leak). Reports of experience concerning diagnosis and treatment of craniosinus fistulae have appeared in the Literature. In the last few years, the endoscopic nasal approach is proving effective as it makes diagnosis much easier and is the least invasive surgical approach, with the greatest percentage of success. Various classifications are being proposed to improve clinical evaluation of CSF leaks and to simplify the diagnostic and therapeutic approach. The most common parameters of classification are: aetiology (traumatic, iatrogenic, non-traumatic, etc.) site, type of flow (high or low pressure) and, as far as concerns treatment, the type of graft used, all of which have contributed to various diagnostic and therapeutic algorithms being proposed. Therefore, the subject seems to be widely schematized and the therapeutic attitude widely agreed. However, one of the diagnostic and therapeutic approaches is now being questioned. For some, it is the heart of the clinical approach, while for others, it is a useful tool yet too dangerous to be used on account of potential side effects: namely, the fluorescein test. This procedure, consisting of intrathecal injection of a colorant (fluorescein), is well known by the Food and Drug Administration (FDA) which neither explicitly prohibits it, nor allows it, intrathecal administration is, therefore, an off label use. As far as the Authors know, authorization of this procedure has not been forthcoming anywhere in the world although the procedure itself is widely employed. As far as concerns the use of intrathecal fluorescein, many scientific papers have been written, clearly supporting its clinical usefulness. One limit to the use of fluorescein

  1. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  2. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  3. Developmental changes in cytosolic coupling between epidermis cells as visualized by photoactivation of fluorescein

    DEFF Research Database (Denmark)

    Liu, Xiangdong; Martens, Helle; Schulz, Alexander

    Developmental changes in cytosolic coupling between epidermis cells as visualized by photoactivation of fluorescein.......Developmental changes in cytosolic coupling between epidermis cells as visualized by photoactivation of fluorescein....

  4. Estimating retinal vascular permeability using the adiabatic approximation to the tissue homogeneity model with fluorescein videoangiography

    Science.gov (United States)

    Tichauer, Kenneth M.; Osswald, Christian R.; Dosmar, Emily; Guthrie, Micah J.; Hones, Logan; Sinha, Lagnojita; Xu, Xiaochun; Mieler, William F.; St. Lawrence, Keith; Kang-Mieler, Jennifer J.

    2015-06-01

    Clinical symptoms of diabetic retinopathy are not detectable until damage to the retina reaches an irreversible stage, at least by today's treatment standards. As a result, there is a push to develop new, "sub-clinical" methods of predicting the onset of diabetic retinopathy before the onset of irreversible damage. With diabetic retinopathy being associated with the accumulation of long-term mild damage to the retinal vasculature, retinal blood vessel permeability has been proposed as a key parameter for detecting preclinical stages of retinopathy. In this study, a kinetic modeling approach used to quantify vascular permeability in dynamic contrast-enhanced medical imaging was evaluated in noise simulations and then applied to retinal videoangiography data in a diabetic rat for the first time to determine the potential for this approach to be employed clinically as an early indicator of diabetic retinopathy. Experimental levels of noise were found to introduce errors of less than 15% in estimates of blood flow and extraction fraction (a marker of vascular permeability), and fitting of rat retinal fluorescein angiography data provided stable maps of both parameters.

  5. Intravitreal bevacizumab versus laser treatment in type 1 retinopathy of prematurity: report on fluorescein angiographic findings.

    Science.gov (United States)

    Lepore, Domenico; Quinn, Graham E; Molle, Fernando; Baldascino, Antonio; Orazi, Lorenzo; Sammartino, Maria; Purcaro, Velia; Giannantonio, Carmen; Papacci, Patrizia; Romagnoli, Costantino

    2014-11-01

    To compare the structural outcome at 9 months of eyes treated with intravitreal injection of bevacizumab with fellow eyes treated with conventional laser photoablation in zone I type 1 retinopathy of prematurity (ROP). Single randomized controlled trial. All inborn babies with type 1 zone I ROP at a single institution were included in the study. One eye was randomized to receive an intravitreal injection of 0.5 mg bevacizumab; the fellow eye received conventional laser photoablation. Digital fundus photographs and fluorescein angiography (FA) using the RetCam (Clarity Medical Systems Inc., Pleasanton, CA) were performed before treatment and 9 months after treatment. Presence of retinal and choroidal abnormalities on FA at 9 months. Thirteen infants were enrolled; 1 died 3 months after birth. One laser-treated eye progressed to stage 5 retinal detachment. The remaining 23 eyes had favorable structural results at the 9-month follow-up and provided FA results. At 9 months of age, all eyes treated with a bevacizumab injection were noted to have abnormalities at the periphery (large avascular area, abnormal branching, shunt) or the posterior pole (hyperfluorescent lesion, absence of foveal avascular zone). These posterior and peripheral lesions were not observed in the majority of the lasered eyes. This study documents significant vascular and macular abnormalities of eyes in the bevacizumab group. Long-lasting implications of these abnormalities for visual function of the child need to be studied. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Raman spectroscopy in investigations of mechanism of binding of human serum albumin to molecular probe fluorescein

    International Nuclear Information System (INIS)

    Vlasova, I M; Saletsky, A M

    2008-01-01

    The mechanism of binding of molecular probe fluorescein to molecules of human serum albumin was studied by the Raman spectroscopy method. The position of binding Center on human serum albumin molecule for fluorescein is determined. The amino acid residues of albumin molecule, participating in binding of fluorescein at different pH values of solution, are established. The conformation rearrangements of globules of human serum albumin, taking place at binding of fluorescein at different pH values of solution, are registered

  7. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  8. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  9. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  10. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  11. Microscopic oxygen imaging based on fluorescein bleaching efficiency measurements

    DEFF Research Database (Denmark)

    Beutler, Martin; Heisterkamp, Ines M.; Piltz, Bastian

    2014-01-01

    by a charge-coupled-device (ccd) camera mounted on a fluorescence microscope allowed a pixelwise estimation of the ratio function in a microscopic image. Use of a microsensor and oxygen-consuming bacteria in a sample chamber enabled the calibration of the system for quantification of absolute oxygen......Photobleaching of the fluorophore fluorescein in an aqueous solution is dependent on the oxygen concentration. Therefore, the time-dependent bleaching behavior can be used to measure of dissolved oxygen concentrations. The method can be combined with epi-fluorescence microscopy. The molecular...... states of the fluorophore can be expressed by a three-state energy model. This leads to a set of differential equations which describe the photobleaching behavior of fluorescein. The numerical solution of these equations shows that in a conventional wide-field fluorescence microscope, the fluorescence...

  12. Evaluation of intravenous fluorescein in intradermal allergy testing in psittacines.

    Science.gov (United States)

    Nett, Claudia S; Hosgood, Giselle; Heatley, J Jill; Foil, Carol S; Tully, Thomas N

    2003-12-01

    This study was designed to improve the clinical feasibility of intradermal skin testing of psittacine birds using intravenous fluorescein stain. Twenty-five healthy, anaesthetized Hispaniolan Amazon parrots (Amazona ventralis) were injected intravenously with 10 mg kg-1 fluorescein-sodium 1% followed by intradermal injections of 0.02 mL phosphate-buffered saline, histamine phosphate (1:100,000 w/v) and codeine phosphate (1:100,000 w/v) at the sternal apteria. Wheal diameters of reaction sites were measured grossly and under illumination with a Wood's lamp after 5 and 10 min. Fluorescence-enhanced injection sites were scored between 0 and 2, with 0 equivalent to normal skin and 2 equivalent to a plucked feather follicle. The presence of a fluorescent halo around intradermal injections was also recorded. Under Wood's light illumination at 10 min, histamine and saline were evaluated as positive and negative controls, respectively, based on a positive test having a halo and a score of 2. Sensitivity and specificity were each 76% for halo, 84 and 42% for score and 64 and 77% for combination of score and halo, respectively. Further, mean histamine reactions were significantly larger than codeine phosphate and saline (8.8 +/- 0.4 mm; 7.2 +/- 0.3 mm; 5.9 +/- 0.6 mm); however, this finding was not consistent in individual birds. Wheal size, halo presence and score were affected by site location independent from the injected compound. Intravenous fluorescein improved the readability of avian skin tests; however, the compounds tested raised inconsistent reactions in wheal size, score or halo presence. The compound-independent site effect raises concern on the validity of avian skin testing and warrants investigation of other techniques such as in vitro allergy testing. Based on our findings, intradermal allergy testing in psittacines with or without fluorescein is unreliable and cannot be recommended for practical clinical use.

  13. A nanodiamond-fluorescein conjugate for cell studies

    Science.gov (United States)

    Pedroso-Santana, Seidy; Fleitas-Salazar, Noralvis; Sarabia-Sainz, Andrei; Silva-Campa, Erika; Burgara-Estrella, Alexel; Angulo-Molina, Aracely; Melendrez, Rodrigo; Pedroza-Montero, Martin; Riera, Raul

    2018-03-01

    The use of nanodiamonds in studies with living systems generally involves the modification of their surfaces with functional groups. Fluorescent molecules can be attached to these groups, so that one can know the exact position of the particles in each moment of the interaction with the cells. Here we modify the surface of detonation nanodiamonds and nitrogen-vacancy center nanodiamonds using carboxylation and hydroxylation procedures. Subsequent reactions with silicates and cysteine, before addition of fluorescein allow to obtain fluorescent nano-conjugates. We used confocal microscopy to observe the position of nanodiamonds interacting with HeLa cells. At 3 h post-incubation the green fluorescence is localized in extracellular rounded like-vesicles assemblies while at 24 h the conjugates can be observed inside the cells. The measurement of the fluorescence emitted by both conjugates allowed to find an enhanced emission of fluorescein isothiocyanate (FITC) when the nitrogen-vacancy center is present. We propose the existence of a fluorescence enhancement by electron transference process. The procedure described in this work allows the functionalization of nanodiamonds with FITC and other molecules using functional surface groups and small size mediators. Also, as was proved in our work, the nanodiamond-fluorescein conjugates can be used to track nanoparticles position within the cell. Localization studies are particularly important for drug delivery applications of nanodiamonds.

  14. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  15. MR angiography with Vasovist

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias [University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)], E-mail: goyen@uke.uni-hamburg.de

    2007-12-15

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications.

  16. MR angiography with Vasovist

    International Nuclear Information System (INIS)

    Goyen, Mathias

    2007-01-01

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications

  17. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  18. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    Science.gov (United States)

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  19. The photostability of the commonly used biotin-4-fluorescein probe.

    Science.gov (United States)

    Haack, Richard A; Swift, Kerry M; Ruan, Qiaoqiao; Himmelsbach, Richard J; Tetin, Sergey Y

    2017-08-15

    Biotin-4-fluorescein (B4F) is a commonly used fluorescent probe for studying biotin-(strept)avidin interactions. During a characterization study of an anti-biotin antibody, using B4F as the probe, we noticed a discrepancy in the expected and experimentally determined number of biotin binding sites. Analytical testing showed that the biotin moiety in the probe undergoes a photosensitized oxidation to produce a mixture of biotin sulfoxides which has the potential to impact the quantitation of binding sites using this fluorescent probe. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. MR angiography (MRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-12-01

    The primary goal of vascular imaging is the visualization of morphology and hemodynamics. Catheter angiography has been regarded as a gold standard for this purpose. However, MR angiography (MRA) is now increasingly being recognized as an important noninvasive technique for the depiction of vascular diseases and is partially superseding catheter angiography. The author evaluated the usefulness of MRA in the diagnosis of cerebral aneurysms and moyamoya disease. All aneurysms 5 mm or larger in diameter could be detected and most of those less than 5 mm in diameter were also detectable with using a combination of MIP images, target MIP images and source images. In moyamoya disease, the diagnosis could be made in all. For hemodynamic changes, flow directions in the circle of Willis could be visualized by phase-contrast MRA in a normal volunteer. In addition, MRA successfully showed the patency of surgical collaterals in cases of moyamoya disease. Despite some limitations compared with catheter angiography, MRA has a high sensitivity and specificity in the diagnosis of cerebrovascular abnormalities. Furthermore, screening of cerebral aneurysms or cerebrovascular occlusive diseases seems to be a new, and important indication for MRA. (author).

  1. Fabrication and characterization of vacuum deposited fluorescein thin films

    Energy Technology Data Exchange (ETDEWEB)

    Jalkanen, Pasi, E-mail: pasi.jalkanen@gmail.co [University of Jyvaeskylae, Department of Physics, Nanoscience center (NSC), P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Kulju, Sampo, E-mail: sampo.j.kulju@jyu.f [University of Jyvaeskylae, Department of Physics, Nanoscience center (NSC), P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Arutyunov, Konstantin, E-mail: konstantin.arutyunov@jyu.f [University of Jyvaeskylae, Department of Physics, Nanoscience center (NSC), P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Antila, Liisa, E-mail: liisa.j.antila@jyu.f [University of Jyvaeskylae, Department of Chemistry, Nanoscience center (NSC) P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Myllyperkioe, Pasi, E-mail: pasi.myllyperkio@jyu.f [University of Jyvaeskylae, Department of Chemistry, Nanoscience center (NSC) P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Ihalainen, Teemu, E-mail: teemu.o.ihalainen@jyu.f [University of Jyvaeskylae, Department of Biology, Nanoscience center (NSC), P.O. Box 35, FI-40014 Jyvaeskylae (Finland); Kaeaeriaeinen, Tommi, E-mail: tommi.kaariainen@lut.f [Lappeenranta University of Technology, ASTRal, P.O. Box 181, FI-50101 Mikkeli (Finland); Kaeaeriaeinen, Marja-Leena, E-mail: marja-leena.kaariainen@lut.f [Lappeenranta University of Technology, ASTRal, P.O. Box 181, FI-50101 Mikkeli (Finland); Korppi-Tommola, Jouko, E-mail: jouko.korppi-tommola@jyu.f [University of Jyvaeskylae, Department of Biology, Nanoscience center (NSC), P.O. Box 35, FI-40014 Jyvaeskylae (Finland)

    2011-03-31

    Simple vacuum evaporation technique for deposition of dyes on various solid surfaces has been developed. The method is compatible with conventional solvent-free nanofabrication processing enabling fabrication of nanoscale optoelectronic devices. Thin films of fluorescein were deposited on glass, fluorine-tin-oxide (FTO) coated glass with and without atomically layer deposited (ALD) nanocrystalline 20 nm thick anatase TiO{sub 2} coating. Surface topology, absorption and emission spectra of the films depend on their thickness and the material of supporting substrate. On a smooth glass surface the dye initially forms islands before merging into a uniform layer after 5 to 10 monolayers. On FTO covered glass the absorption spectra are similar to fluorescein solution in ethanol. Absorption spectra on ALD-TiO{sub 2} is red shifted compared to the film deposited on bare FTO. The corresponding emission spectra at {lambda} = 458 nm excitation show various thickness and substrate dependent features, while the emission of films deposited on TiO{sub 2} is quenched due to the effective electron transfer to the semiconductor conduction band.

  2. Fluorescence quenching of fluorescein by Merocyanine 540 in liposomes

    International Nuclear Information System (INIS)

    Toprak, Mahmut; Meryem Aydin, Burcu; Arik, Mustafa; Onganer, Yavuz

    2011-01-01

    The fluorescence quenching of fluorescein (FL) by merociyanine 540 (MC540) was examined in L-egg lecithin phosphatidycholine (PC) liposomes using spectroscopic methods. The type of quenching mechanism (dynamic or static) was evaluated using the Stern-Volmer plots. Findings were also supported by the temperature studies and florescence decay measurements. The Stern-Volmer equation was utilized to calculate bimolecular quenching constants (K q ). Furthermore, the bimolecular quenching constant of the quencher in the liposomes (K SV ), partition coefficient (K p ), binding constant (K), and corresponding thermodynamic parameters ΔH, ΔS, and ΔG were calculated. The quenching property was also used in determining quantitatively (K p ) the partition coefficient of Merociyanini 540 in PC liposome.The obtained data indicated that static quenching occurred in the system and the K SV values decreased with increasing lipid concentration. In addition, thermodynamic analysis suggested that van der Waals interactions and hydrogen bonding were the main acting forces between fluorescein and merociyanine 540 molecules in the medium. - Highlights: → Fluorescence quenching of FL by MC540 in liposome system was analyzed. → Fluorescence quenching mechanism of FL by MC540 was consistent with the static model. → Binding FL to MC540 was spontaneous and carried out by hydrogen bond and van der Waals forces.

  3. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  4. The effect of colloidal silica nanoparticles encapsulated fluorescein dye using micelle entrapment method

    Science.gov (United States)

    Ahmad, Atiqah; Zakaria, Nor Dyana; Lockman, Zainovia; Razak, Khairunisak Abdul

    2018-05-01

    The advancement of nanoparticle-based approaches such as quantum dots (QDs), metallic (Au and Ag) NPs, silica NPs and other types of nanomaterial have led to a large variety of biomolecular imaging and labelling reagents with controlled size and shaped to overcome the limitation of conventional organic dye. In this study, the yellowish green color of fluorescein dye was encapsulated into colloidal silica nanoparticles by using micelle entrapment approach. Two different size of silica nanoparticles encapsulated fluorescein dye (27.7 ± 5.6 and 46.73 ± 4.3 nm) with spherical and monodispered of nanoparticles were synthesised by varying the volume of co-solvent during the synthesis process. The particles size, particles morphology, absorption spectrum and the photostability of fluorescein dye was measured by using dynamic light scaterring (DLS), Transmission Electron Microscope (TEM) and UV-Vis spectrometer. Furthermore, the effect of photostability of of silica nanoparticles encapsulated fluorescein dye was measured under radiation of 200 W of Halogen lamp for 60 minutes. The silica nanoparticles encapsulated fluorescein dye was more stable compared to bare fluorescein dye after the exposure. In conclusion, the photostability of silica nanoparticles encapsulated fluorescein dye was improved compared to bare fluorescein dye, thus silica nanoparticles encapsulation successfully provides protection from the photobleaching and photodegradation of fluorescein dye.

  5. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  6. Synthesis and characterization of acrylate copolymer containing fluorescein functional group

    Energy Technology Data Exchange (ETDEWEB)

    Hui, Guodong; Huang, Weiyun; Song, Yunzhao; Chen, Deben; Zhong, Anyong [Sichuan University, Chengdu (China)

    2013-08-15

    We report a novel method to fabricate fluorescent polymer (F-CPA) based on the esterification between acrylate copolymer (CPA) and fluorescein using N, N-dicyclohexylcarbodiimide (DCC)/4-dimethylaminopyridine (DMAP) as catalyst. The resulting copolymer was characterized by Fourier transform-infrared spectroscopy (FT-IR), gel permeation chromatography (GPC), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), ultraviolet-visible spectroscopy (UV-Vis) and fluorescence spectroscopy. In addition, the influences of concentration, solvents, pH and metal cations (Cu{sup 2+}, Fe{sup 3+} and Zn{sup 2+}) on the fluorescent behaviors of F-CPA are discussed in detail. All those observations suggest that the synthesized F-CPA is an excellent luminescent macromolecular material with simple synthesis method and excellent solubility. Moreover, its sensitive fluorescence response behaviors to solvents, pH and metal cations make it to become a polymer-based probe.

  7. Synthesis and characterization of acrylate copolymer containing fluorescein functional group

    International Nuclear Information System (INIS)

    Hui, Guodong; Huang, Weiyun; Song, Yunzhao; Chen, Deben; Zhong, Anyong

    2013-01-01

    We report a novel method to fabricate fluorescent polymer (F-CPA) based on the esterification between acrylate copolymer (CPA) and fluorescein using N, N-dicyclohexylcarbodiimide (DCC)/4-dimethylaminopyridine (DMAP) as catalyst. The resulting copolymer was characterized by Fourier transform-infrared spectroscopy (FT-IR), gel permeation chromatography (GPC), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), ultraviolet-visible spectroscopy (UV-Vis) and fluorescence spectroscopy. In addition, the influences of concentration, solvents, pH and metal cations (Cu"2"+, Fe"3"+ and Zn"2"+) on the fluorescent behaviors of F-CPA are discussed in detail. All those observations suggest that the synthesized F-CPA is an excellent luminescent macromolecular material with simple synthesis method and excellent solubility. Moreover, its sensitive fluorescence response behaviors to solvents, pH and metal cations make it to become a polymer-based probe

  8. Bactericidal Antibiotics Increase Hydroxyphenyl Fluorescein Signal by Altering Cell Morphology

    DEFF Research Database (Denmark)

    Paulander, Wilhelm; Wang, Ying; Folkesson, Sven Anders

    2014-01-01

    It was recently proposed that for bactericidal antibiotics a common killing mechanism contributes to lethality involving indirect stimulation of hydroxyl radical (OH center dot) formation. Flow cytometric detection of OH center dot by hydroxyphenyl fluorescein (HPF) probe oxidation was used...... to support this hypothesis. Here we show that increased HPF signals in antibiotics-exposed bacterial cells are explained by fluorescence associated with increased cell size, and do not reflect reactive oxygen species (ROS) concentration. Independently of antibiotics, increased fluorescence was seen...... for elongated cells expressing the oxidative insensitive green fluorescent protein (GFP). Although our data question the role of ROS in lethality of antibiotics other research approaches point to important interplays between basic bacterial metabolism and antibiotic susceptibility. To underpin...

  9. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  10. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  11. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  12. Synthesis of taurine–fluorescein conjugate and evaluation of its retina-targeted efficiency in vitro

    Directory of Open Access Journals (Sweden)

    Meihong Huang

    2014-12-01

    Full Text Available In this work, retinal penetration of fluorescein was achieved in vitro by covalent attachment of taurine to fluorescein, yielding the F–Tau conjugate. Nuclear magnetic resonance (NMR and high resolution mass spectrometry (HRMS were used to confirm the successful synthesis of F–Tau. The cellular uptake of F–Tau in adult retinal pigment epithelial cells (ARPE-19 and human retinal microvascular endothelial cells (hRMECs was visualized via confocal scanning microscopy. The results indicated an improvement of solubility and a reduction of logP of F–Tau compared with fluorescein. As compared with fluorescein, F–Tau showed little toxicity, and was retained longer by cells in uptake experiments. F–Tau also displayed higher transepithelial permeabilities than fluorescein in ARPE-19 and hRMECs monolayer cells (P<0.05. These results showed that taurine may be a useful ligand for targeting small-molecule hydrophobic pharmaceuticals into the retina.

  13. Comparison of eosin and fluorescein conjugates for the photoinitiation of cell-compatible polymer coatings.

    Directory of Open Access Journals (Sweden)

    Jacob L Lilly

    Full Text Available Targeted photopolymerization is the basis for multiple diagnostic and cell encapsulation technologies. While eosin is used in conjunction with tertiary amines as a water-soluble photoinitiation system, eosin is not widely sold as a conjugate with antibodies and other targeting biomolecules. Here we evaluate the utility of fluorescein-labeled bioconjugates to photopolymerize targeted coatings on live cells. We show that although fluorescein conjugates absorb approximately 50% less light energy than eosin in matched photopolymerization experiments using a 530 nm LED lamp, appreciable polymer thicknesses can still be formed in cell compatible environments with fluorescein photosensitization. At low photoinitiator density, eosin allows more sensitive initiation of gelation. However at higher functionalization densities, the thickness of fluorescein polymer films begins to rival that of eosin. Commercial fluorescein-conjugated antibodies are also capable of generating conformal, protective coatings on mammalian cells with similar viability and encapsulation efficiency as eosin systems.

  14. Comparison of eosin and fluorescein conjugates for the photoinitiation of cell-compatible polymer coatings.

    Science.gov (United States)

    Lilly, Jacob L; Gottipati, Anuhya; Cahall, Calvin F; Agoub, Mohamed; Berron, Brad J

    2018-01-01

    Targeted photopolymerization is the basis for multiple diagnostic and cell encapsulation technologies. While eosin is used in conjunction with tertiary amines as a water-soluble photoinitiation system, eosin is not widely sold as a conjugate with antibodies and other targeting biomolecules. Here we evaluate the utility of fluorescein-labeled bioconjugates to photopolymerize targeted coatings on live cells. We show that although fluorescein conjugates absorb approximately 50% less light energy than eosin in matched photopolymerization experiments using a 530 nm LED lamp, appreciable polymer thicknesses can still be formed in cell compatible environments with fluorescein photosensitization. At low photoinitiator density, eosin allows more sensitive initiation of gelation. However at higher functionalization densities, the thickness of fluorescein polymer films begins to rival that of eosin. Commercial fluorescein-conjugated antibodies are also capable of generating conformal, protective coatings on mammalian cells with similar viability and encapsulation efficiency as eosin systems.

  15. Ultrasonic irradiation enhanced the ability of Fluorescein-DA-Fe(III) on sonodynamic and sonocatalytic damages of DNA molecules.

    Science.gov (United States)

    Wu, Qiong; Chen, Xia; Jia, Lizhen; Wang, Yi; Sun, Ying; Huang, Xingjun; Shen, Yuxiang; Wang, Jun

    2017-11-01

    The interaction of DNA with Bis [N,N-bis (carboxymethyl) aminomethyl] fluorescein-Ferrous(III) (Fluorescein-DA-Fe(III)) with dual functional (sonodynamic and sonocatalytic) activity was studied by UV-vis spectroscopy, fluorescence spectroscopy, FT-IR spectroscopy, circular dichroism (CD) spectroscopy and viscosity measurements. And then, the damage of DNA caused by Fluorescein-DA-Fe(III) under ultrasonic irradiation (US) was researched by agarose gel electrophoresis and cytotoxicity assay. Meanwhile, some influenced factors such as ultrasonic irradiation time and Fluorescein-DA-Fe(III) concentration on the damage degree of DNA molecules were also examined. As a control, for Bis [N,N-bis (carboxymethyl) aminomethyl] fluorescein (Fluorescein-DA), the same experiments were carried out. The results showed that both Fluorescein-DA-Fe(III) and Fluorescein-DA can interact with DNA molecules. Under ultrasonic irradiation, Fluorescein-DA shows sonodynamic activity, which can damage DNA molecules. While, in the presence of Fe(III) ion, the Fluorescein-DA-Fe(III) displays not only sonodynamic activity but also sonocatalytic activity under ultrasonic irradiation, which injures DNA more serious than Fluorescein-DA. The researches confirmed the dual function (sonodynamic activity and sonocatalytic activity) of Fluorescein-DA-Fe(III) and expanded the usage of Fluorescein-DA-Fe(III) as a sonosensitizer in sonodynamic therapy (SDT). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  17. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  18. Nonenhanced MR angiography techniques

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Kroepil, P.; Blondin, D.; Schmitt, P.

    2011-01-01

    Especially in regard to the potential risks for the development of nephrogenic systemic fibrosis (NSF) following the administration of Gadolinium-based contrast material, nonenhanced MR angiography (MRA) methods are becoming ever more important. Besides well-established time-of-flight (TOF) and phase-contrast (PC) MRA, alternative imaging techniques based on balanced steady-state free precession (bSSFP) and turbo-spin-echo (TSE) sequences are increasingly used in combination with or without arterial spin labeling (ASL) strategies. This article provides an overview of the principles and clinical values of different nonenhanced MRA techniques. In addition, recent nonenhanced MRA developments are presented. (orig.)

  19. Extraction of Capillary Non-perfusion from Fundus Fluorescein Angiogram

    Science.gov (United States)

    Sivaswamy, Jayanthi; Agarwal, Amit; Chawla, Mayank; Rani, Alka; Das, Taraprasad

    Capillary Non-Perfusion (CNP) is a condition in diabetic retinopathy where blood ceases to flow to certain parts of the retina, potentially leading to blindness. This paper presents a solution for automatically detecting and segmenting CNP regions from fundus fluorescein angiograms (FFAs). CNPs are modelled as valleys, and a novel technique based on extrema pyramid is presented for trough-based valley detection. The obtained valley points are used to segment the desired CNP regions by employing a variance-based region growing scheme. The proposed algorithm has been tested on 40 images and validated against expert-marked ground truth. In this paper, we present results of testing and validation of our algorithm against ground truth and compare the segmentation performance against two others methods.The performance of the proposed algorithm is presented as a receiver operating characteristic (ROC) curve. The area under this curve is 0.842 and the distance of ROC from the ideal point (0,1) is 0.31. The proposed method for CNP segmentation was found to outperform the watershed [1] and heat-flow [2] based methods.

  20. Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein.

    Science.gov (United States)

    Ghoneim, Ehab M

    2014-01-01

    To evaluate the use of red-free light for the measurement of intraocular pressure (IOP) using a Goldmann applanation tonometer without fluorescein. This cross-sectional study was carried out on 500 eyes in 250 patients attending the Ophthalmology Outpatient Clinic at Suez Canal University Hospital. The IOP was measured using a Goldmann applanation tonometer mounted on a Haag-Streit slit-lamp. The measurements were performed first using red-free light without fluorescein. Then the measurements were repeated with cobalt blue light and topical fluorescein on the same eyes. The mean IOP was 15.23 ± 3.3 (SD) mm Hg using the red-free light without fluorescein, whereas it was 15.78 ± 3.7 (SD) mm Hg when measured using cobalt blue light after the application of fluorescein to the conjunctival sac. This difference was not statistically significant. Measurement of IOP with a Goldmann applanationtonometer with red-free light and without the use of fluorescein is simple, saves time, and gives an accurate IOP measurement relative to the traditional measurement technique with cobalt blue light and topical fluorescein.

  1. Magnetic resonance angiography

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Gamroth, A.H.; Schad, L.R.; Semmler, W.; Kaick, G. van; Tuengerthal, S.J.; Hausmann, R.

    1992-01-01

    MR angiography (MRA) proved to be promising combined to MR-Imaging (MRI) in the assessment of intrathoracic masses. Sequential FLASH 2D-angiograms were acquired in breathhold technique using the following parameters: TR=30 ms, TE=10 ms, FA=30deg. Section thickness was 5 mm with 1 mm overlap between sequential sections. Individual conditions of the examination were achieved by an automatised control procedure. Targeted MIP-postprocessing resulted in 3D-reconstructions illustrating vascular anatomy and avoiding superimposition. Presentation should be done by cine-mode for better spatial impression. This method was evaluated in a prospective study of 21 patients with malignant pulmonary and mediastinal masses in addition to spin-echo imaging. The diagnostic contribution concerning the relationship between the mass and the vasculature like displacement, stenosis, and poststenotic perfusion defect were assessed. (orig.) [de

  2. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  3. Sputum Microscopy With Fluorescein Diacetate Predicts Tuberculosis Infectiousness.

    Science.gov (United States)

    Datta, Sumona; Sherman, Jonathan M; Tovar, Marco A; Bravard, Marjory A; Valencia, Teresa; Montoya, Rosario; Quino, Willi; D'Arcy, Nikki; Ramos, Eric S; Gilman, Robert H; Evans, Carlton A

    2017-09-01

    Sputum from patients with tuberculosis contains subpopulations of metabolically active and inactive Mycobacterium tuberculosis with unknown implications for infectiousness. We assessed sputum microscopy with fluorescein diacetate (FDA, evaluating M. tuberculosis metabolic activity) for predicting infectiousness. Mycobacterium tuberculosis was quantified in pretreatment sputum of patients with pulmonary tuberculosis using FDA microscopy, culture, and acid-fast microscopy. These 35 patients' 209 household contacts were followed with prevalence surveys for tuberculosis disease for 6 years. FDA microscopy was positive for a median of 119 (interquartile range [IQR], 47-386) bacteria/µL sputum, which was 5.1% (IQR, 2.4%-11%) the concentration of acid-fast microscopy-positive bacteria (2069 [IQR, 1358-3734] bacteria/μL). Tuberculosis was diagnosed during follow-up in 6.4% (13/209) of contacts. For patients with lower than median concentration of FDA microscopy-positive M. tuberculosis, 10% of their contacts developed tuberculosis. This was significantly more than 2.7% of the contacts of patients with higher than median FDA microscopy results (crude hazard ratio [HR], 3.8; P = .03). This association maintained statistical significance after adjusting for disease severity, chemoprophylaxis, drug resistance, and social determinants (adjusted HR, 3.9; P = .02). Mycobacterium tuberculosis that was FDA microscopy negative was paradoxically associated with greater infectiousness. FDA microscopy-negative bacteria in these pretreatment samples may be a nonstaining, slowly metabolizing phenotype better adapted to airborne transmission. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  4. Optical Coherence Tomography Angiography in Retinal Vascular Diseases and Choroidal Neovascularization

    Directory of Open Access Journals (Sweden)

    Rodolfo Mastropasqua

    2015-01-01

    Full Text Available Purpose. To assess the ability of optical coherence tomography-angiography (OCT-A to show and analyze retinal vascular patterns and the choroidal neovascularization (CNV in retinal vascular diseases. Methods. Seven eyes of seven consecutive patients with retinal vascular diseases were examined. Two healthy subjects served as controls. All eyes were scanned with the SD-OCT XR Avanti (Optovue Inc, Fremont CA, USA. Split spectrum amplitude decorrelation angiography algorithm was used to identify the blood flow within the tissue. Fluorescein angiography (FA and indocyanine green angiography (ICGA with Spectralis HRA + OCT (Heidelberg Engineering GmbH were performed. Results. In healthy subjects OCT-A visualized major macular vessels and detailed capillary networks around the foveal avascular zone. Patients were affected with myopic CNV (2 eyes, age-related macular degeneration related (2, branch retinal vein occlusion (BRVO (2, and branch retinal artery occlusion (BRAO (1. OCT-A images provided distinct vascular patterns, distinguishing perfused and nonperfused areas in BRVO and BRAO and recognizing the presence, location, and size of CNV. Conclusions. OCT-A provides detailed images of retinal vascular plexuses and quantitative data of pathologic structures. Further studies are warranted to define the role of OCT-A in the assessment of retinovascular diseases, with respect to conventional FA and ICG-A.

  5. [Quenched fluorescein: a reference dye for instrument response function of TCSPC].

    Science.gov (United States)

    Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua

    2014-08-01

    Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.

  6. Trihydroxytrioxatriangulene - An Extended Fluorescein and a Ratiometric pH Sensor

    DEFF Research Database (Denmark)

    Westerlund, Fredrik; Hildebrandt, Christoffer Boli; Sørensen, Thomas Just

    2010-01-01

    Fluorescein ver. 2.0: A new, highly fluorescent, pH-sensitive trihydroxytrioxatriangulenium dye (H-TOTA) has been synthesised and characterised. The dye is closely related to fluorescein and may be considered to be a two-dimensional extended version. This new dye can exist in four different proto...... protonation states (see graphic) depending on the pH, and its use as a sensitive fluorescent ratiometric pH probe in a physiological buffer is demonstrated....

  7. En-face optical coherence tomography angiography of neovascularization elsewhere in hemicentral retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Sogawa K

    2015-10-01

    Full Text Available Kenji Sogawa, Taiji Nagaoka, Akihiro Ishibazawa, Atsushi Takahashi, Tomofumi Tani, Akitoshi Yoshida Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan Purpose: To evaluate how the growth of neovascularization elsewhere (NVE was delineated in an eye with hemicentral retinal vein occlusion (CRVO using optical coherence tomography (OCT angiography. Patients and methods: We examined a 64-year-old man diagnosed with hemi-CRVO. The area around the occluded vein was scanned using a spectral-domain OCT device (RTVue XR Avanti. Blood flow was detected using the split-spectrum amplitude-decorrelation angiography (SSADA algorithm. Color fundus photography, fluorescein angiography (FA, and OCT angiography examinations were performed at the first visit and at 3 and 6 months postpresentation. Results: At the first visit, FA revealed delayed retinal venous filling and extensive areas of capillary nonperfusion. The patient underwent a trial of intravitreal ranibizumab injection (0.5 mg/0.05 mL for the treatment of macular edema. At 3 months postpresentation, there was no NVE around the occluded vein in the en-face SSADA image, but at 6 months, NVE appeared on the occluded veins. The en-face SSADA image showed the NVE structure in the fibrovascular membrane on the occluded vein more clearly than FA images. Conclusion: OCT angiography clearly visualized the sprouting of NVE in an eye with hemi-CRVO. New findings of the vascular structure of NVE in hemi-CRVO were revealed using the en-face SSADA algorithm. Keywords: OCT angiography, hemi-CRVO, NVE

  8. Microscope-Integrated Optical Coherence Tomography Angiography in the Operating Room in Young Children With Retinal Vascular Disease.

    Science.gov (United States)

    Chen, Xi; Viehland, Christian; Carrasco-Zevallos, Oscar M; Keller, Brenton; Vajzovic, Lejla; Izatt, Joseph A; Toth, Cynthia A

    2017-05-01

    Intraoperative optical coherence tomography (OCT) has gained traction as an important adjunct for clinical decision making during vitreoretinal surgery, and OCT angiography (OCTA) has provided novel insights in clinical evaluation of retinal diseases. To date, these two technologies have not been applied in combination to evaluate retinal vascular disease in the operating suite. To conduct microscope-integrated, swept-source OCTA (MIOCTA) in children with retinal vascular disease. In this case report analysis, OCT imaging in pediatric patients, MIOCTA images were obtained during examination under anesthesia from a young boy with a history of idiopathic vitreous hemorrhage and a female infant with familial exudative vitreoretinopathy. Side-by-side comparison of research MIOCT angiograms and clinically indicated fluorescein angiograms. In 2 young children with retinal vascular disease, the MIOCTA images showed more detailed vascular patterns than were visible on the fluorescein angiograms although within a more posterior field of view. The MIOCTA system allowed visualization of small pathological retinal vessels in the retinal periphery that were obscured in the fluorescein angiograms by fluorescein staining from underlying, preexisting laser scars. This is the first report to date of the use of MIOCTA in the operating room for young children with retinal vascular disease. Further optimization of this system may allow noninvasive detailed evaluation of retinal vasculature during surgical procedures and in patients who could not cooperate with in-office examinations.

  9. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  10. Vasovist-enhanced MR angiography

    International Nuclear Information System (INIS)

    Goyen, M.; Shamsi, K.; Schoenberg, S.O.

    2006-01-01

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  11. Vasovist-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Shamsi, K. [Berlex Lab., Inc., Montville, NJ (United States); Schoenberg, S.O. [Dept. of Clinical Radiology, Univ. Hospitals Grosshadern, Munich (Germany)

    2006-02-15

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  12. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  13. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  14. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  15. Electrochemiluminescence of fluorescein in alkaline solution at a polycrystalline gold electrode

    International Nuclear Information System (INIS)

    Shi Mingjuan; Cui Hua

    2007-01-01

    The electrochemiluminescence (ECL) behavior of fluorescein at a polycrystalline gold electrode was studied under conventional cyclic voltammetric conditions. Five ECL peaks were observed at 0.94 (ECL-1), 1.51 (ECL-2), 1.34 (ECL-3), -0.06 (ECL-4), -0.73 to -1.11 V (ECL-5, a broad weak wave) (vs. SCE), respectively, on the curve of ECL intensity versus potential. These ECL peaks were found to depend on the pH of the solution, supporting electrolyte, potential scan ranges and directions. The emitter of ECL peaks was identified as fluorescein or eosin Y produced on the electrode by analyzing the ECL spectra and fluorescence spectra. The mechanisms for ECL peaks have been proposed due to the reactions of fluorescein and the electro-oxidation product of fluorescein with various oxygen-containing species in the solution or electrogenerated at different applied potentials such as O 2 , O 2 .- , HO 2 - , and BrO - . Singlet molecular oxygen was generated during the reactions and transferred its energy to the ECL emitter such as fluorescein or eosin Y, emitting light

  16. Diagnostic impact of anterior segment angiography of limbal stem cell insufficiency in PAX6-related aniridia.

    Science.gov (United States)

    Käsmann-Kellner, Barbara; Latta, Lorenz; Fries, Fabian N; Viestenz, Arne; Seitz, Berthold

    2018-04-01

    PAX6 is a master gene of ocular development and postnatal ocular equilibrium. Congenital aniridia is the hallmark of PAX6 gene haploinsufficiency (Chr. 11 p. 13), but PAX6-associated aniridia is a profound, progressive pan-ocular developmental disorder often leading to blindness. There is congenital visual impairment with advancing loss of vision mainly due to secondary glaucoma and to corneal blindness caused by limbal stem cell insufficiency (LSCI). LSCI leads to ARK (aniridia-related keratopathy), which typically develops in four stages. Incipient LSCI with vessels starting to grow into the cornea can be imaged by fluorescein anterior segment angiography, which enables fine vessels to be more easily detected than by routine slit lamp examination, especially in patients with nystagmus. Thus, clinical stage 1 ARK is often diagnosed at stage 2 by angiography. Corneal neovascularizations often start at the 12 and 6 positions and subsequently progress circumferentially, not at the 3 and 9 positions as previously believed. Anterior segment angiography can provide an easily standardizable tool for monitoring progress, treatment-induced regress or stabilization of ARK. Especially in children, angiography could be used to monitor new treatment regimens for reducing LSCI. Angiography could enable treatment to begin earlier to preserve corneal hemostasis. In addition, the fact that vascularization often starts at the subpalpebral 6 and 12 positions as opposed to the 3 and 9 positions raises more questions concerning factors that promote LSCI and related corneal injuries. Clin. Anat. 31:392-397, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  17. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  18. Structural studies of the mechanism for biosensing antibiotics in a fluorescein-labeled β-lactamase

    Directory of Open Access Journals (Sweden)

    Wong Kwok-Yin

    2011-03-01

    Full Text Available Abstract Background β-lactamase conjugated with environment-sensitive fluorescein molecule to residue 166 on the Ω-loop near its catalytic site is a highly effective biosensor for β-lactam antibiotics. Yet the molecular mechanism of such fluorescence-based biosensing is not well understood. Results Here we report the crystal structure of a Class A β-lactamase PenP from Bacillus licheniformis 749/C with fluorescein conjugated at residue 166 after E166C mutation, both in apo form (PenP-E166Cf and in covalent complex form with cefotaxime (PenP-E166Cf-cefotaxime, to illustrate its biosensing mechanism. In the apo structure the fluorescein molecule partially occupies the antibiotic binding site and is highly dynamic. In the PenP-E166Cf-cefatoxime complex structure the binding and subsequent acylation of cefotaxime to PenP displaces fluorescein from its original location to avoid steric clash. Such displacement causes the well-folded Ω-loop to become fully flexible and the conjugated fluorescein molecule to relocate to a more solvent exposed environment, hence enhancing its fluorescence emission. Furthermore, the fully flexible Ω-loop enables the narrow-spectrum PenP enzyme to bind cefotaxime in a mode that resembles the extended-spectrum β-lactamase. Conclusions Our structural studies indicate the biosensing mechanism of a fluorescein-labelled β-lactamase. Such findings confirm our previous proposal based on molecular modelling and provide useful information for the rational design of β-lactamase-based biosensor to detect the wide spectrum of β-lactam antibiotics. The observation of increased Ω-loop flexibility upon conjugation of fluorophore may have the potential to serve as a screening tool for novel β-lactamase inhibitors that target the Ω-loop and not the active site.

  19. Optical coherence tomography angiography in acute arteritic and non-arteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Balducci, Nicole; Morara, Mariachiara; Veronese, Chiara; Barboni, Piero; Casadei, Nicoletta Lelli; Savini, Giacomo; Parisi, Vincenzo; Sadun, Alfredo A; Ciardella, Antonio

    2017-11-01

    The purpose of our study was to describe the feature of acute non-arteritic or arteritic anterior ischemic optic neuropathy (NA-AION and A-AION) using optical coherence tomography angiography (OCT-A) and to compare it with fluorescein angiography (FA) and indocyanine green angiography (ICGA). In this retrospective, observational case-control study four NA-AION patients and one A-AION patient were examined by FA, ICGA and OCT-A within 2 weeks from disease presentation. The characteristics of the images were analyzed. Optic nerve head (ONH) and radial peripapillary capillaries (RPC) vessel densities (VDs) were compared between NA-AION and controls. In two of four NA-AION cases and in the A-AION patient, OCT-A clearly identified the boundary of the ischemic area at the level of the optic nerve head, which was comparable to optic disc filling defects detected by FA. In the other two NA-AION cases, a generalized leakage from the disc was visible with FA, yet OCT-A still demonstrated sectorial peripapillary capillary network reduction. Both ONH and RPC VDs were reduced in NA-AION patients, when compared to controls. OCT-A was able to identify microvascular defects and VD reduction in cases of acute optic disc edema due to NA-AION and A-AION. OCT-A provides additional information in ischemic conditions of the optic nerve head.

  20. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  1. Risk of renal allograft rejection following angiography

    International Nuclear Information System (INIS)

    Heideman, M.; Claes, G.; Nilson, A.E.

    1976-01-01

    In a retrospective study of 173 immediately functioning primary kidney transplants, correlation between angiography and renal allograft rejection was studied during the first 14 days. It was found that rejection was more frequent in kidneys undergoing angiography than in those not undergoing angiography. It was also found that in kidneys undergoing angiography an overwhelming number of the rejections started the day after angiography. These differences in rejection frequency could not be explained by differences in HLA matching or the origin of the kidneys. These findings suggest a possible connection indicating that the angiography might elicit an acute rejection episode. A possible mechanism for starting this reaction might be activation of the complement system which was found in 50 percent of the patients undergoing angiography in peripheral blood and in 100 percent when studied in vitro

  2. Synthesis of Rhodamines from Fluoresceins Using Pd-Catalyzed C–N Cross-Coupling

    Science.gov (United States)

    2011-01-01

    A unified, convenient, and efficient strategy for the preparation of rhodamines and N,N′-diacylated rhodamines has been developed. Fluorescein ditriflates were found to undergo palladium-catalyzed C–N cross-coupling with amines, amides, carbamates, and other nitrogen nucleophiles to provide direct access to known and novel rhodamine derivatives, including fluorescent dyes, quenchers, and latent fluorophores. PMID:22091952

  3. Fluoride-induced modulation of ionic transport in asymmetric nanopores functionalized with "caged" fluorescein moieties.

    Science.gov (United States)

    Ali, Mubarak; Ahmed, Ishtiaq; Ramirez, Patricio; Nasir, Saima; Cervera, Javier; Niemeyer, Christof M; Ensinger, Wolfgang

    2016-04-28

    We demonstrate experimentally and theoretically a nanofluidic fluoride sensing device based on a single conical pore functionalized with "caged" fluorescein moieties. The nanopore functionalization is based on an amine-terminated fluorescein whose phenolic hydroxyl groups are protected with tert-butyldiphenylsilyl (TBDPS) moieties. The protected fluorescein (Fcn-TBDPS-NH2) molecules are then immobilized on the nanopore surface via carbodiimide coupling chemistry. Exposure to fluoride ions removes the uncharged TBDPS moieties due to the fluoride-promoted cleavage of the silicon-oxygen bond, leading to the generation of negatively charged groups on the fluorescein moieties immobilized onto the pore surface. The asymmetrical distribution of these groups along the conical nanopore leads to the electrical rectification observed in the current-voltage (I-V) curve. On the contrary, other halides and anions are not able to induce any significant ionic rectification in the asymmetric pore. In each case, the success of the chemical functionalization and deprotection reactions is monitored through the changes observed in the I-V curves before and after the specified reaction step. The theoretical results based on the Nernst-Planck and Poisson equations further demonstrate the validity of an experimental approach to fluoride-induced modulation of nanopore current rectification behaviour.

  4. Fluorescein transport properties across artificial lipid membranes, Caco-2 cell monolayers and rat jejunum.

    Science.gov (United States)

    Berginc, Katja; Zakelj, Simon; Levstik, Lea; Ursic, Darko; Kristl, Albin

    2007-05-01

    Membrane transport characteristics of a paracellular permeability marker fluorescein were evaluated using artificial membrane, Caco-2 cell monolayers and rat jejunum, all mounted in side-by-side diffusion cells. Modified Ringer buffers with varied pH values were applied as incubation salines on both sides of artificial membrane, cell culture monolayers or rat jejunum. Passive transport according to pH partition theory was determined using all three permeability models. In addition to that, active transport of fluorescein in the M-S (mucosal-to-serosal) direction through rat jejunum was observed. The highest M-S P(app) values regarding the active transport through the rat jejunum were observed in incubation saline with pH 6.5. Fluorescein transport through the rat jejunum was inhibited by DIDS (4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid) and alpha-CHC (alpha-cyano-4-hydroxycinnamic acid). Thus, we assume that two pH-dependent influx transporters could be involved in the fluorescein membrane transport through the intestinal (jejunal) epithelium. One is very likely an MCT (monocarboxylic acid cotransporter) isoform, inhibited by specific MCT inhibitor alpha-CHC, while the involvement of the second one with overlapping substrate/inhibitor specificities (most probably a member of the organic anion-transporting polypeptide family, inhibited at least partially by DIDS) could not be excluded.

  5. Absence of cell communication for fluorescein and dansylated amino acids in an electronic coupled cell system

    NARCIS (Netherlands)

    Venrooij, G.E.P.M. van; Hax, W.M.A.; Schouten, V.J.A.; Denier van der Gon, J.J.; Vorst, H.A. van der

    1975-01-01

    Quantitative evaluation of the diffusion process of sodium fluorescein and dansylated amino acids in the salivary gland of the larvae of Drosophila hydei reveals that the differences in specific permeability between the junctional and nonjunctional membranes, as found for small ions, do not apply to

  6. Is fasting necessary for elective cerebral angiography?

    Science.gov (United States)

    Kwon, O-K; Oh, C W; Park, H; Bang, J S; Bae, H-J; Han, M K; Park, S-H; Han, M H; Kang, H-S; Park, S-K; Whang, G; Kim, B-C; Jin, S-C

    2011-05-01

    In order to prevent unexpected events such as aspiration pneumonia, cerebral angiography has been performed under fasting in most cases. We investigated prospectively the necessity of fasting before elective cerebral angiography. The study is an open-labeled clinical trial without random allocation. In total, 2554 patients who underwent elective cerebral angiography were evaluated on development of nausea, vomiting, and pulmonary aspiration during and after angiography. Potential risks and benefits associated with fasting were provided in written documents and through personal counseling to patients before the procedure. The patients chose their fasting or nonfasting option. No restriction in diet was given after angiography. The patients were observed for 24 hours. Nausea and vomiting during and within 1 hour after angiography was considered as a positive event associated with cerebral angiography. The overall incidence of nausea and vomiting during and within 1 hour after angiography was 1.05% (27/2554 patients). There was no patient with pulmonary aspiration. No statistical difference in nausea and vomiting development between the fasting and the diet groups was found. The incidence of nausea and vomiting associated with cerebral angiography is low and not affected by diet or fasting. Pulmonary aspiration had no difference between the diet and the fasting group. Our study suggests that fasting may not be necessary for patients who undergo elective cerebral angiography.

  7. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  8. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  9. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  10. Pulmonary angiography with lopamidol 370

    International Nuclear Information System (INIS)

    Braun, S.D.; Saeed, M.; Perlmutt, L.M.; Newman, G.E.; Illescas, F.F.; Cohan, R.H.; Dunnick, N.R.

    1986-01-01

    Fifty-one consecutive patients who underwent pulmonary angiography with iopamidol, 370 mg/ml, were studied prospectively. Patients were asked to grade any heat or pain felt on injection, and were observed for coughing. Right atrial and pulmonary artery pressures were obtained before the first and after the final contrast agent injection. Pressure changes were compared with those in a consecutive group of 25 patients who underwent examinations performed with Na-meglumine diatrizoate, 370 mg/ml. Film quality was evaluated for patient motion. Iopamidol generated marked discomfort in only three patients. Pressure changes were largely unremarkable. In no case was there any significant motion artifact secondary to coughing. Iopamidol is a safe, well-tolerated contrast agent for pulmonary angiography. It improves image quality by nearly eliminating coughing

  11. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  12. Imaging choroidal neovascular membrane using en face swept-source optical coherence tomography angiography

    Directory of Open Access Journals (Sweden)

    Moussa M

    2017-10-01

    Full Text Available Magdy Moussa,1,2 Mahmoud Leila,3 Hagar Khalid1,2 1Ophthalmology Department, Faculty of Medicine, Tanta University, Tanta, Egypt; 2MEDIC Eye Center, Tanta, Egypt; 3Retina Department, Research Institute of Ophthalmology, Giza, Egypt Purpose: The aim of this study was to assess the efficacy of swept-source optical coherence tomography angiography (SS-OCTA in delineating the morphology of choroidal neovascular membrane (CNV. Patients and methods: This was a retrospective observational case series reviewing clinical data and fundus fluorescein angiography (FFA, swept-source optical coherence tomography (SS-OCT, and SS-OCTA images of patients with CNV and comparing the findings. The swept-source technology enables deeper penetration and superior axial resolution. The incorporated blood flow detection algorithm, optical coherence tomography angiography ratio analysis (OCTARA, enables visualization of CNV in vivo without the need for dye injection. Results: The study included 136 eyes of 105 patients. Active lesions on SS-OCTA images showed increased capillary density, extensive arborization, vascular anastomosis and looping, and peri-lesional hollow. Inactive lesions showed decreased capillary density, presence of large linear vessels, and presence of feeder vessels supplying the CNV. We detected positive correlation between SS-OCTA, FFA, and SS-OCT images in 97% of eyes. In the remaining 3%, SS-OCTA confirmed the absence of CNV, whereas FFA and SS-OCT either were inconclusive in the diagnosis of CNV or yielded false-positive results. Conclusion: SS-OCT and SS-OCTA represent a reproducible risk-free analog for FFA in imaging CNV. SS-OCTA is particularly versatile in cases where FFA and SS-OCT are inconclusive. Keywords: swept-source OCT, OCT angiography, imaging of CNV, OCTARA algorithm

  13. Aqueous Angiography: Real-Time and Physiologic Aqueous Humor Outflow Imaging.

    Directory of Open Access Journals (Sweden)

    Sindhu Saraswathy

    Full Text Available Trabecular meshwork (TM bypass surgeries attempt to enhance aqueous humor outflow (AHO to lower intraocular pressure (IOP. While TM bypass results are promising, inconsistent success is seen. One hypothesis for this variability rests upon segmental (non-360 degrees uniform AHO. We describe aqueous angiography as a real-time and physiologic AHO imaging technique in model eyes as a way to simulate live AHO imaging.Pig (n = 46 and human (n = 6 enucleated eyes were obtained, orientated based upon inferior oblique insertion, and pre-perfused with balanced salt solution via a Lewicky AC maintainer through a 1mm side-port. Fluorescein (2.5% was introduced intracamerally at 10 or 30 mm Hg. With an angiographer, infrared and fluorescent (486 nm images were acquired. Image processing allowed for collection of pixel information based on intensity or location for statistical analyses. Concurrent OCT was performed, and fixable fluorescent dextrans were introduced into the eye for histological analysis of angiographically active areas.Aqueous angiography yielded high quality images with segmental patterns (p<0.0001; Kruskal-Wallis test. No single quadrant was consistently identified as the primary quadrant of angiographic signal (p = 0.06-0.86; Kruskal-Wallis test. Regions of high proximal signal did not necessarily correlate with regions of high distal signal. Angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways.Aqueous angiography is a real-time and physiologic AHO imaging technique in model eyes.

  14. Analysis of Fundus Fluorescein Angiogram Based on the Hessian Matrix of Directional Curvelet Sub-bands and Distance Regularized Level Set Evolution.

    Science.gov (United States)

    Soltanipour, Asieh; Sadri, Saeed; Rabbani, Hossein; Akhlaghi, Mohammad Reza

    2015-01-01

    This paper presents a new procedure for automatic extraction of the blood vessels and optic disk (OD) in fundus fluorescein angiogram (FFA). In order to extract blood vessel centerlines, the algorithm of vessel extraction starts with the analysis of directional images resulting from sub-bands of fast discrete curvelet transform (FDCT) in the similar directions and different scales. For this purpose, each directional image is processed by using information of the first order derivative and eigenvalues obtained from the Hessian matrix. The final vessel segmentation is obtained using a simple region growing algorithm iteratively, which merges centerline images with the contents of images resulting from modified top-hat transform followed by bit plane slicing. After extracting blood vessels from FFA image, candidates regions for OD are enhanced by removing blood vessels from the FFA image, using multi-structure elements morphology, and modification of FDCT coefficients. Then, canny edge detector and Hough transform are applied to the reconstructed image to extract the boundary of candidate regions. At the next step, the information of the main arc of the retinal vessels surrounding the OD region is used to extract the actual location of the OD. Finally, the OD boundary is detected by applying distance regularized level set evolution. The proposed method was tested on the FFA images from angiography unit of Isfahan Feiz Hospital, containing 70 FFA images from different diabetic retinopathy stages. The experimental results show the accuracy more than 93% for vessel segmentation and more than 87% for OD boundary extraction.

  15. Early Detection of Diabetic Retinopathy in Fluorescent Angiography Retinal Images Using Image Processing Methods

    Directory of Open Access Journals (Sweden)

    Meysam Tavakoli

    2010-12-01

    Full Text Available Introduction: Diabetic retinopathy (DR is the single largest cause of sight loss and blindness in the working age population of Western countries; it is the most common cause of blindness in adults between 20 and 60 years of age. Early diagnosis of DR is critical for preventing vision loss so early detection of microaneurysms (MAs as the first signs of DR is important. This paper addresses the automatic detection of MAs in fluorescein angiography fundus images, which plays a key role in computer assisted diagnosis of DR, a serious and frequent eye disease. Material and Methods: The algorithm can be divided into three main steps. The first step or pre-processing was for background normalization and contrast enhancement of the image. The second step aimed at detecting landmarks, i.e., all patterns possibly corresponding to vessels and the optic nerve head, which was achieved using a local radon transform. Then, MAs were extracted, which were used in the final step to automatically classify candidates into real MA and other objects. A database of 120 fluorescein angiography fundus images was used to train and test the algorithm. The algorithm was compared to manually obtained gradings of those images. Results: Sensitivity of diagnosis for DR was 94%, with specificity of 75%, and sensitivity of precise microaneurysm localization was 92%, at an average number of 8 false positives per image. Discussion and Conclusion: Sensitivity and specificity of this algorithm make it one of the best methods in this field. Using local radon transform in this algorithm eliminates the noise sensitivity for microaneurysm detection in retinal image analysis.

  16. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  17. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  18. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  19. Analysis of chemical equilibrium of silicon-substituted fluorescein and its application to develop a scaffold for red fluorescent probes.

    Science.gov (United States)

    Hirabayashi, Kazuhisa; Hanaoka, Kenjiro; Takayanagi, Toshio; Toki, Yuko; Egawa, Takahiro; Kamiya, Mako; Komatsu, Toru; Ueno, Tasuku; Terai, Takuya; Yoshida, Kengo; Uchiyama, Masanobu; Nagano, Tetsuo; Urano, Yasuteru

    2015-09-01

    Fluorescein is a representative green fluorophore that has been widely used as a scaffold of practically useful green fluorescent probes. Here, we report synthesis and characterization of a silicon-substituted fluorescein, i.e., 2-COOH TokyoMagenta (2-COOH TM), which is a fluorescein analogue in which the O atom at the 10' position of the xanthene moiety of fluorescein is replaced with a Si atom. This fluorescein analogue forms a spirolactone ring via intramolecular nucleophilic attack of the carboxylic group in a pH-dependent manner. Consequently, 2-COOH TM exhibits characteristic large pH-dependent absorption and fluorescence spectral changes: (1) 2-COOH TM is colorless at acidic pH, whereas fluorescein retains observable absorption and fluorescence even at acidic pH, and the absorption maximum is also shifted; (2) the absorption spectral change occurs above pH 7.0 for 2-COOH TM and below pH 7.0 for fluorescein; (3) 2-COOH TM shows a much sharper pH response than fluorescein because of its pKa inversion, i.e., pKa1 > pKa2. These features are also different from those of a compound without the carboxylic group, 2-Me TokyoMagenta (2-Me TM). Analysis of the chemical equilibrium between pH 3.0 and 11.0 disclosed that 2-COOH TM favors the colorless and nonfluorescent lactone form, compared with fluorescein. Substitution of Cl atoms at the 4' and 5' positions of the xanthene moiety of 2-COOH TM to obtain 2-COOH DCTM shifted the equilibrium so that the new derivative exists predominantly in the strongly fluorescent open form at physiological pH (pH 7.4). To demonstrate the practical utility of 2-COOH DCTM as a novel scaffold for red fluorescent probes, we employed it to develop a probe for β-galactosidase.

  20. Teaching Old Dyes New Tricks: Biological Probes Built from Fluoresceins and Rhodamines.

    Science.gov (United States)

    Lavis, Luke D

    2017-06-20

    Small-molecule fluorophores, such as fluorescein and rhodamine derivatives, are critical tools in modern biochemical and biological research. The field of chemical dyes is old; colored molecules were first discovered in the 1800s, and the fluorescein and rhodamine scaffolds have been known for over a century. Nevertheless, there has been a renaissance in using these dyes to create tools for biochemistry and biology. The application of modern chemistry, biochemistry, molecular genetics, and optical physics to these old structures enables and drives the development of novel, sophisticated fluorescent dyes. This critical review focuses on an important example of chemical biology-the melding of old and new chemical knowledge-leading to useful molecules for advanced biochemical and biological experiments.

  1. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  2. Functionality screen of streptavidin mutants by non-denaturing SDS-PAGE using biotin-4-fluorescein.

    Science.gov (United States)

    Humbert, Nicolas; Ward, Thomas R

    2008-01-01

    Site-directed mutagenesis or directed evolution of proteins often leads to the production of inactive mutants. For streptavidin and related proteins, mutations may lead to the loss of their biotin-binding properties. With high-throughput screening methodologies in mind, it is imperative to detect, prior to the high-density protein production, the bacteria that produce non-functional streptavidin isoforms. Based on the incorporation of biotin-4-fluorescein in streptavidin mutants present in Escherichia coli bacterial extracts, we detail a functional screen that allows the identification of biotin-binding streptavidin variants. Bacteria are cultivated in a small volume, followed by a rapid treatment of the cells; biotin-4-fluorescein is added to the bacterial extract and loaded on an Sodium Dodecyl Sulfate Poly-Acrylamide Gel Electrophoresis (SDS-PAGE) under non-denaturing conditions. Revealing is performed using a UV transilluminator. This screen is thus easy to implement, cheap and requires only readily available equipment.

  3. Net Fluorescein Flux Across Corneal Endothelium Strongly Suggests Fluid Transport is due to Electro-osmosis.

    Science.gov (United States)

    Sanchez, J M; Cacace, V; Kusnier, C F; Nelson, R; Rubashkin, A A; Iserovich, P; Fischbarg, J

    2016-08-01

    We have presented prior evidence suggesting that fluid transport results from electro-osmosis at the intercellular junctions of the corneal endothelium. Such phenomenon ought to drag other extracellular solutes. We have investigated this using fluorescein-Na2 as an extracellular marker. We measured unidirectional fluxes across layers of cultured human corneal endothelial (HCE) cells. SV-40-transformed HCE layers were grown to confluence on permeable membrane inserts. The medium was DMEM with high glucose and no phenol red. Fluorescein-labeled medium was placed either on the basolateral or the apical side of the inserts; the other side carried unlabeled medium. The inserts were held in a CO2 incubator for 1 h (at 37 °C), after which the entire volume of the unlabeled side was collected. After that, label was placed on the opposite side, and the corresponding paired sample was collected after another hour. Fluorescein counts were determined with a (Photon Technology) DeltaScan fluorometer (excitation 380 nm; emission 550 nm; 2 nm bwth). Samples were read for 60 s. The cells utilized are known to transport fluid from the basolateral to the apical side, just as they do in vivo in several species. We used 4 inserts for influx and efflux (total: 20 1-h periods). We found a net flux of fluorescein from the basolateral to the apical side. The flux ratio was 1.104 ± 0.056. That difference was statistically significant (p = 0.00006, t test, paired samples). The endothelium has a definite restriction at the junctions. Hence, an asymmetry in unidirectional fluxes cannot arise from osmosis, and can only point instead to paracellular solvent drag. We suggest, once more, that such drag is due to electro-osmotic coupling at the paracellular junctions.

  4. Using multiphoton fluorescence lifetime imaging to characterize liver damage and fluorescein disposition in liver in vivo

    Science.gov (United States)

    Thorling, Camilla A.; Studier, Hauke; Crawford, Darrell; Roberts, Michael S.

    2016-03-01

    Liver disease is the fifth most common cause of death and unlike many other major causes of mortality, liver disease rates are increasing rather than decreasing. There is no ideal measurement of liver disease and although biopsies are the gold standard, this only allows for a spot examination and cannot follow dynamic processes of the liver. Intravital imaging has the potential to extract detailed information over a larger sampling area continuously. The aim of this project was to investigate whether multiphoton and fluorescence lifetime imaging microscopy could detect early liver damage and to assess whether it could detect changes in metabolism of fluorescein in normal and diseased livers. Four experimental groups were used in this study: 1) control; 2) ischemia reperfusion injury; 3) steatosis and 4) steatosis with ischemia reperfusion injury. Results showed that multiphoton microscopy could visualize morphological changes such as decreased fluorescence of endogenous fluorophores and the presence of lipid droplets, characteristic of steatosis. Fluorescence lifetime imaging microscopy showed increase in NADPH in steatosis with and without ischemia reperfusion injury and could detect changes in metabolism of fluorescein to fluorescein monoglurcuronide, which was impaired in steatosis with ischemia reperfusion injury. These results concluded that the combination of multiphoton microscopy and fluorescence lifetime imaging is a promising method of assessing early stage liver damage and that it can be used to study changes in drug metabolism in the liver as an indication of liver disease and has the potential to replace the traditional static liver biopsy currently used.

  5. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  6. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  7. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  8. OCT angiography of acute non-arteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Rougier, M-B; Delyfer, M-N; Korobelnik, J-F

    2017-02-01

    To describe changes of the retinal peripapillary microvasculature on optical coherence tomography angiography (OCT-A) in non-arteritic anterior ischemic optic (NAION) neuropathy. Observational study of 10 patients at the acute phase of NAION. OCT-A was performed using a 3mm×3mm square centered on the optic disc (Cirrus HD-OCT with Angioplex, Carl Zeiss Meditec, Dublin, CA). A qualitative comparison was made with the healthy fellow eye of each patient. All patients had a fluorescein angiography (HRA2, Heidelberg, Germany) and a visual field examination (Octopus 101 ® , Haag-Streit, USA). In the affected eyes, OCT-A showed clear modifications in the radial peripapillary network. In all these eyes, a focal disappearance of the superficial capillary radial pattern was present, twisted and irregular. In 8 eyes, there was also a lack of vascularization in some focal areas, appearing as dark areas. No correlation was found between the topography of the vascular alteration shown on OCT-A and visual field pattern defects. OCT-A is a new imaging technology able to demonstrate easily and safely the changes in the peripapillary capillary network during the acute phase of NAION. These changes are likely related to a decrease of the prelaminar optic nerve blood flow during the acute phase of NAION. Visual field defects are not correlated with OCT-A images, suggesting that they may be due mainly to disturbances in posterior ciliary artery blood flow. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease.

    Science.gov (United States)

    Giannakouras, Panagiotis; Andreanos, Konstantinos; Giavi, Barbara; Diagourtas, Andreas

    2017-01-01

    To report a case of Vogt-Koyanagi-Harada (VKH) disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA). Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT) were performed at baseline, as well as OCTA. A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  10. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease

    Directory of Open Access Journals (Sweden)

    Panagiotis Giannakouras

    2017-07-01

    Full Text Available Purpose: To report a case of Vogt-Koyanagi-Harada (VKH disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA. Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  11. Magnetic resonance angiography of arteriovenous malformation in the brainstem

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    The magnetic resonance (MR) angiography appearance of arteriovenous malformation (AVM) in the tegmentum and pons is described. The interpeduncular perforating branches of the posterior cerebral artery and median pontine branches of the basilar artery were seen more clearly by MR angiography than by conventional angiography. MR angiography was very useful for the follow-up of AVM after stereotactic radiosurgery. (author).

  12. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  13. Angiography of primary bone tumors

    International Nuclear Information System (INIS)

    Keyl, W.; Kunkel, B.

    1982-01-01

    To determine the type of a tumour by means of angiography is problematical. Considering that tumour-simulating lesions (myositis ossificans, modular synoritis) can also show pathological blood vessel formations and AV-shunts the interpretation of vessel-architectonic criteria must be done very carefully. The finding of some individual signs of malignancy does not justify the diagnosis of ''malignant tumour''. Only the ''anarchic vessel picture'' (Freyschmidt) with changing caliber, corkscrew vessels, interrupted vessels, unregular tumour colouring, arteria-venous shunts and possibly also tumour invasion into vessels makes a malignant process very likely. The absence of these criteria, however, does not exclude malignancy. Non-vascularised malignant tumours can only lead to a displacement of vessels without an angiographic proof of the tumour itself. (orig./APR) [de

  14. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  15. Indicating pressure and environmental effects by means of the spectral shift with rhodamine B and fluorescein

    Directory of Open Access Journals (Sweden)

    R. M. Johann

    2015-07-01

    Full Text Available Fluorescence absorption and emission wavelengths can be influenced by environmental conditions, such as pressure, temperature and concentration. Here those effects are explored with an emphasis on determining the potential of rhodamine B and fluorescein as high-pressure indicators. The red shift of the emission peak maxima of rhodamine B and fluorescein are investigated in dependence of pressure up to 200 MPa using as the solvents water, ethanol and poly(dimethylsiloxane (PDMS with rhodamine B and water, polystyrene beads and melamine resin beads with fluorescein. Emission spectra recording and peak fitting is done automatically at time intervals of down to a second and with 0.3 nm wavelength resolution. The wavenumber-pressure relation for rhodamine B reveals increasing divergence from linear behavior in the sequence of the solvents water, ethanol and silicone rubber. Graphical correlation of the data diverging only slightly from linearity with a selection of polarity functions is enabled using the concept of ‘deviation from linearity (DL’ plots. Using the example of rhodamine B dissolved in PDMS elastomer it is shown that there is a temperature induced irreversible molecular reordering, when scanning between 3 and ∼50°C, and a polarity change in the proximity of the embedded dye molecule. Swelling studies are performed with PDMS containing rhodamine B, where the elastomer is first put in water, then in ethanol and again in water. There a complex solvent exchange process is revealed in the elastomer demonstrating the feasibility of fluorescence spectroscopy, when observing variations in wavelength, to indicate and enlighten molecular rearrangements and swelling dynamics in the polymer, and polarity changes and solvent exchange processes in the dye solvation shell.

  16. Modulating fluorescence quantum yield of highly concentrated fluorescein using differently shaped green synthesized gold nanoparticles

    International Nuclear Information System (INIS)

    John, Jisha; Thomas, Lincy; Kurian, Achamma; George, Sajan D.

    2016-01-01

    The interaction of dye molecules with differently shaped nanoparticles is of great interest owing to the potential applications in areas of bioimaging, sensing and photodynamic therapy (biology) as well as solar cells (photonics) applications. For such applications, noble metallic nanoparticles are commonly employed to either enhance or quench the luminescence of a nearby fluorophore. However, in most of the studies, the dye concentration is limited to avoid self-quenching. This paper reports the influence of differently shaped gold nanoparticles (spherical, bean and star), prepared via green synthesis, on the emission behavior as well as on the fluorescence quantum yield of fluorescein dye at concentrations for which self-quenching occurs. The emission behavior is probed via laser based steady state fluorescence whereas quantum yield is measured using a dual beam laser based thermal lens technique. The experimentally observed fluorescence quenching with a concomitant increase in thermal lens signal in the vicinity of nanoparticles are explained in terms of nonradiative energy transfer between the donor and the acceptor. Further, the influence of pH of the prepared gold nanofluid on the absorption, emission as well as quantum yield are also accounted. These studies elucidate that even at high concentrations of dye, the gold nanoparticle and its shape clearly influences the optical properties of nearby dye molecules and thus can be exploited for future applications. - Highlights: • Green synthesis of differently shaped gold nanoparticles. • Tailoring emission properties of fluorescein with respect to nanoparticle concentration and shape. • Tailoring the quantum yield of highly concentrated fluorescein with nanoparticles.

  17. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  18. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  19. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  20. Interaction and photodegradation characteristics of fluorescein dye in presence of ZnO nanoparticles.

    Science.gov (United States)

    Bardhan, Munmun; Mandal, Gopa; Ganguly, Tapan

    2011-04-01

    The interaction between xanthene dye Fluorescein (Fl) and zinc oxide (ZnO) nanoparticles is investigated under physiological conditions. From the analysis of the steady state and time resolved spectroscopic studies in aqueous solution static mode is found to be responsible in the mechanism of fluorescence quenching of the dye Fl in presence of ZnO. ZnO nanoparticles are used as photocatalyst in order to degrade Fl dye. At pH 7, a maximum degradation efficiency of 44.4% of the dye has been achieved in presence of ZnO as a nanophotocatalyst and the photodegradation follows second-order kinetics.

  1. Cochlear microdialysis for quantification of dexamethasone and fluorescein entry into scala tympani during round window administration.

    Science.gov (United States)

    Hahn, Hartmut; Kammerer, Bernd; DiMauro, Andre; Salt, Alec N; Plontke, Stefan K

    2006-02-01

    Before new drugs for the treatment of inner ear disorders can be studied in controlled clinical trials, it is important that their pharmacokinetics be established in inner ear fluids. Microdialysis allows drug levels to be measured in perilymph without the volume disturbances and potential cerebrospinal fluid contamination associated with fluid sampling. The aims of this study were to show: (i) that despite low recovery rates from miniature dialysis probes, significant amounts of drug are removed from small fluid compartments, (ii) that dialysis sampling artifacts can be accounted for using computer simulations and (iii) that microdialysis allows quantification of the entry rates through the round window membrane (RWM) into scala tympani (ST). Initial experiments used microdialysis probes in small compartments in vitro containing sodium fluorescein. Stable concentrations were observed in large compartments (1000 microl) but significant concentration declines were observed in smaller compartments (100, 10 and 5.6 microl) comparable to the size of the inner ear. Computer simulations of these experiments closely approximated the experimental data. In in vivo experiments, sodium fluorescein 10 mg/ml and dexamethasone-dihydrogen-phosphate disodium salt 8 mg/ml were simultaneously applied to the RWM of guinea pigs. Perilymph concentration in the basal turn of ST was monitored using microdialysis. The fluorescein concentration reached after 200 min application (585+/-527 microg/ml) was approximately twice that of dexamethasone phosphate (291+/-369 microg/ml). Substantial variation in concentrations was found between animals by approximately a factor of 34 for fluorescein and at least 41 for dexamethasone phosphate. This is, to a large extent, thought to be the result of the RWM permeability varying in different animals. It was not caused by substance analysis variations, because two different analytic methods were used and the concentration ratio between the two

  2. The determination of the conduction mechanism and optical band gap of fluorescein sodium salt

    International Nuclear Information System (INIS)

    Yakuphanoglu, Fahrettin; Sekerci, Memet; Evin, Ertan

    2006-01-01

    The electrical conductivity and optical properties of fluorescein sodium salt in the temperature range of 295-370 K have been investigated. Various conduction models described in the literature were used to elucidate the charge transport mechanism of the compound. It is found that the charge transfer mechanism of the compound is understood in terms of grain boundary scattering. It can be evaluated that the obtained electronic parameters such as mobility, conductivity at room temperature, activation energy and optical band gap suggest that the compound is an organic semiconductor

  3. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  4. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  5. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot Fishman, a radiologist ... question you might have, visit Radiology Info dot org. Thank you for your time and for your ...

  6. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  8. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  9. Kinetic Analysis of the Uptake and Release of Fluorescein by Metal-Organic Framework Nanoparticles

    Directory of Open Access Journals (Sweden)

    Tobias Preiß

    2017-02-01

    Full Text Available Metal-organic framework nanoparticles (MOF NPs are promising guest-host materials with applications in separation, storage, catalysis, and drug delivery. However, on- and off-loading of guest molecules by porous MOF nanostructures are still poorly understood. Here we study uptake and release of fluorescein by two representative MOF NPs, MIL-100(Fe and MIL-101(Cr. Suspensions of these MOF NPs exhibit well-defined size distributions and crystallinity, as verified by electron microscopy, dynamic light scattering, and X-ray diffraction. Using absorbance spectroscopy the equilibrium dissociation constants and maximum numbers of adsorbed fluorescein molecules per NP were determined. Time-resolved fluorescence studies reveal that rates of release and loading are pH dependent. The kinetics observed are compared to theoretical estimates that account for bulk diffusion into NPs, and retarded internal diffusion and adsorption rates. Our study shows that, rather than being simple volumetric carriers, MOF-NPs are dominated by internal surface properties. The findings will help to optimize payload levels and develop release strategies that exploit varying pH for drug delivery.

  10. Angiography in tumors of cartilaginous genesis

    International Nuclear Information System (INIS)

    Korolev, V.I.

    1986-01-01

    Angiography was used for 122 patients with tumors and tumor-like processes of the cartilage. Angiography was carried out by the S. Seldinger method. Normal angioarchitecture was observed in 16 patients with benign tumors (20 patients), characters of malignant tumor are determined in 4 patients. Normal angioarchitecture is determined in 9.4% of patients with chondrosarcoma (102 patients). The examination carried out showed that angiographic symptotics in chondrosarcomas varied depending on the stage, localization and the degree of morphologic differentiation

  11. Comparison of digital color fundus imaging and fluorescein angiographic findings for the early detection of diabetic retinopathy in young type 1 diabetic patients.

    Science.gov (United States)

    Kapsala, Z; Anastasakis, A; Mamoulakis, D; Maniadaki, I; Tsilimbaris, M

    2018-01-01

    To compare the findings from digital 7-field color fundus (CF) photography and fundus fluorescein angiography (FFA) in young patients with diabetes mellitus (DM) type 1 without known diabetic retinopathy. In this prospective, observational cohort study, 54 type 1 diabetic patients were recruited. Participants had been diagnosed with diabetes mellitus (DM) for at least 6 years, had Best Corrected Visual Acuity of 20/25 or better and did not have any known retinal pathology. One hundred and seven eyes were analyzed. All patients underwent a complete ophthalmic examination in the Retina Service of a University Eye Clinic including digital CF imaging and FFA. The mean age of the patients was 18.6 years. Mean duration of DM was 11.3 years, and mean haemoglobin A1c (HbA1c) level was 8.6%. Of the 107 eyes, 8 eyes (7.5%) showed microvascular abnormalities on CF images, while FFA images revealed changes in 26 eyes (24.3%). Hence, 18 of the 26 eyes showing abnormalities on FFA did not show any abnormalities on CF images. Mean DM duration in the patient group with detectable microvascular changes was found to be significantly higher compared to patients without changes, while no difference in HbA1c levels, serum lipid levels or blood pressure was observed. Comparison of digital CF and FFA findings for the detection of diabetic microvascular changes in type 1 diabetic patients showed that FFA reveals more information about retinal vascular pathology for early detection of diabetic retinopathy. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Simple Improvisation to Enhance Utility of Fluorescein Sodium in Resection of Intracranial Lesions at Routine Neurosurgical Centers.

    Science.gov (United States)

    Gollapudi, Prakash Rao; Mohammed, Imran; Pittala, Sandeep R; Kotha, Arjun Reddy; Reddycherla, Naga Raju; Ginjupally, Dhanunjaya Rao

    2018-04-01

    Fluorescein sodium is one of the fluorophores that is used in the resection of intracranial lesions. It is commonly used along with a customized microscope, which is expensive and not available universally. In this study, we describe a simple, inexpensive method for better visualization of intracranial and spinal cord lesions with fluorescein. After a test dose, 20 mg/kg of fluorescein sodium was administered intravenously at the time of intubation. A blue light source was used before resection for precise localization of the intracranial lesions after durotomy. Most of the resection was done under the white light, while the blue light was used intermittently to delineate the pathologic tissue from the normal tissue and to ensure safe maximal resection. The intensity of fluorescein staining under white light and blue light was noted. The study comprised 40 cases of gliomas, meningiomas, abscesses, spinal cord tumors, and cerebellopontine angle lesions. Thirty-five lesions showed good fluorescence under the blue light, which helped us achieve better resection of the pathologic lesions. Fluorescein sodium is a safe dye; it can be used to aid in precise localization and safe maximal resection of the pathologic tissue with the help of a blue light source at any center with challenged resources. The blue light enhances the fluorescence and visualization of the pathologic tissue, and this technique can be adopted by any surgeon without much difficulty even with a basic neurosurgical setup. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. MR angiography in pediatric neurological disorders

    International Nuclear Information System (INIS)

    Lee, B.C.P.; Park, T.S.; Kaufman, B.A.

    1995-01-01

    MR angiography using 3D and 2D time-of-flight techniques were used to evaluate pediatric neurological disorders. MRA (arteriography) and MRV (venography) were abnormal in 63 and 45 cases, respectively. Conventional cerebral angiography was performed in 30 cases. These techniques were compared with MRI and conventional angiography. In addition, the value of MR angiography for surgical planning was subjectively evaluated. Our results showed that intracranial vessels were invariably better shown on MR angiography than on MRI. MRA and MRV were most useful in evaluating vascular distortions related to congenital brain malformations and intracranial tumors. MRA was valuable in detecting arterial narrowing but overestimated the degree of stenosis compared with conventional angiography. MRV was the technique of choice for evaluation of dural sinus and cerebral venous thrombosis and compression. MRA played little to no role in preoperative planning of vascular malformations and aneurysms. It did not appear to be accurate in assessing tumor vascularity or lesions in small arteries and arteritis. (orig.)

  14. MR angiography of cerebral aneurysms

    International Nuclear Information System (INIS)

    Miki, Hitoshi; Tanada, Shuji; Sakaki, Saburo; Hamamoto, Ken; Sadamoto, Kazuhiko.

    1992-01-01

    Time-of-flight (TOF) MR angiography (MRA) and phase-contrast (PC) MRA are examined clinically for evaluating cerebral aneurysms. In the morphological diagnosis of cerebral aneurysms, three-dimensional (3D) MRA is superior to two-dimensional (2D) MRA because 3D MRA has a higher S/N ratio and a higher spatial resolution. However, it is difficult to decide which, 3D TOF MRA or 3D PC MRA, is superior, for both methods have many scan parameters. In our study, 3D PC MRA was performed using two methods; one had the same acquisition time as 3D TOF MRA, while the other had the same spatial resolution as 3D TOF MRA. The detectability of aneurysms by each MRA method was evaluated in comparison with 3D TOF MRA. In fifteen patients (6 males and 9 females), a total of 16 cerebral aneurysms (3 ruptured and 13 unruptured) were studied. The lesion sizes ranged from 2.5 to 18 mm. All the 16 lesions were examined by means of 3D TOF MRA, 3D PC MRA, and conventional angiography. MR imaging was performed with a 1.5 tesla MRI system (Signa). All of the 16 cerebral aneurysms were detected by 3D TOF MRA, while only 11 of them were detected by 3D PC MRA. When 3D PC MRA was performed with the same acquisition time as 3D TOF MRA, 3D PC MRA was superior in showing one of the 7 aneurysms. When 3D PC MRA was performed with same spatial resolution as 3D TOF MRA, 3D PC MRA was superior in showing two of the 10 aneurysms. 3D TOF MRA was superior to 3D PC MRA in the detection of cerebral aneurysms because of the long acquisition times and the different flow velocity, which induced different signal intensities between the aneurysms and parent arteries in 3D PC MRA. 3D PC MRA was superior to 3D TOF MRA in patients with large thrombotic aneurysms of the internal carotid artery. We consider that 3D TOF MRA should be the first choice for screening and following-up cerebral aneurysms. 3D PC MRA should then be performed for large cerebral aneurysms in addition to 3D TOF MRA. (author)

  15. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  16. Digital angiography of camel foot

    International Nuclear Information System (INIS)

    Dehghani, S.N.; Kohkiloyehzadeh, M.; Sazmand, A.

    2011-01-01

    In this study, angiography of normal digits of camel has been accomplished, and the vessels of digits and its distribution have been evaluated to be compared with abnormal digits in the future studies. The thoracic and pelvic limb of 16 camels were collected immediately following slaughter. The palmar and plantar arteries were isolated and catheterised by 18-gauge angiocatheter needle; perfused by 40Ð’–50 ml of iodinated compound injected into each vessel. Angiograms were obtained using dorsopalmer, dorsoplanter and latero-medial projections. In the pelvic limb, above the fetlock joint, the deep palmar arch communicates with the median artery via the anastomotic branch, forming the superfcial palmar arch, from which two branches were clear, 1-palmar common digital artery IV that divides into palmar proper digital arteries IV and V, close to the lateral accessory (ffth) digit. 2-Palmar common digital artery III, produces the first branch and continues distally near the middle of the proximal phalanx, it gives off two palmar branches of the proximal phalanx. Vascular distribution of the pelvic limb was similar to thoracic limb, carrying the name of plantar instead of palmar

  17. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  18. A batch and fixed bed column study for fluorescein removal using chitosan modified by epichlorohydrin.

    Science.gov (United States)

    Silva, P M O; Francisco, J E; Cajé, J C M; Cassella, R J; Pacheco, W F

    2018-01-02

    This study evaluates the feasibility of commercial chitosan (CQ) and modified chitosan (MQ) by epichlorohydrin to be used as a solid phase to remove fluorescein (FSC) from aqueous solutions by two different approaches: in batch and on a fixed column bed. For the batch study, all parameters that influence sorption capacity were evaluated, such as: pH, mass, ionic strength, temperature and time of contact. In the optimized condition, 75% removal was obtained for FSC using CQ, while the modification allowed an increase up to 99%, as well as an increase in the stability of the polymer. In the fixed column bed study, the influence of all the parameters was evaluated through breakthrough curves, and the thermodynamics parameters of each approach were obtained. The results of these studies demonstrate that the modification with epichlorohydrin enhanced the sorptive properties (from 35% to 95% in fixed bed experiments) and the polymer stability (making it insoluble), making it suitable to be used in wastewater treatment.

  19. Photoluminescence of PMMA doped with fluorescein and carbosilane dendrimer and lasing in PBG resonance cavity

    International Nuclear Information System (INIS)

    Li Chunfang; Jin Feng; Dong Xianzi; Chen Weiqiang; Duan Xuanming

    2007-01-01

    Carbosilane dendrimers with terminal allyl groups were synthesized and used to encapsulate the allyl derivative of fluorescein (allyl-FL) doped in PMMA. The optical property of this system was investigated and the results showed that the concentration of allyl-FL in PMMA could be increased to 4.5 wt% without decrease of the luminescence efficiency by adding the dendrimer into the system. The allyl-FL/dendrimer/PMMA film was embedded into a resonance cavity composed of two pieces of photonic band gap (PBG) materials to form a new-type solid-state laser. A laser emission at 589 nm was obtained when excited with a third harmonic generation (THG) of a pulsed Nd:YAG laser (355 nm) and its full-width at half-maximum of the spectrum was 1.7 nm

  20. Effects of molecular interactions and the existence of different molecular forms of sodium fluoresceinate in solutions

    International Nuclear Information System (INIS)

    Golubeva, N.G.

    1989-01-01

    The results of measurement of fluorescence and absorption spectra of sodium fluoresceinate (FLNa) in different solutions and blood plasma are presented. The influence of solvent nature, its polarity, medium concentration and acidity on frequency, intensity and shape of fluorescence and absorption lines was analyzed. A general medium effect on fluorescence line spectral absorption was calculated from Lippert's equation. The influence of specific interactions has been analyzed on the example of acid-base interactions and hydrogen bonds in two- and multicomponent solutions. Computer processing of the spectra obtained allows to separate some forms of existing fluorophor molecules and to get data on the dynamics of their changes in different solutions. A special attention was given to the analysis of absorption and fluorescence bands of FLNa at its interaction with different proteins and lipids in solutions. From the analysis of data obtained a number of conclusions was drawn on the state of fluophor at its interactions with biological media. (author)

  1. Histopathological confirmation of similar intramucosal distribution of fluorescein in both intravenous administration and local mucosal application for probe-based confocal laser endomicroscopy of the normal stomach.

    Science.gov (United States)

    Nonaka, Kouichi; Ohata, Ken; Ban, Shinichi; Ichihara, Shin; Takasugi, Rumi; Minato, Yohei; Tashima, Tomoaki; Matsuyama, Yasushi; Takita, Maiko; Matsuhashi, Nobuyuki; Neumann, Helmut

    2015-12-16

    Probe-based confocal laser endomicroscopy (pCLE) is capable of acquiring in vivo magnified cross-section images of the gastric mucosa. Intravenous injection of fluorescein sodium is used for confocal imaging. However, it is still under debate if local administration of the dye to the mucosa is also effective for confocal imaging as it is not yet clear if topical application also reveals the intramucosal distribution of fluorescein. The objective of this study was to evaluate the intramucosal distribution of fluorescein sodium after topical application and to compare the distribution to the conventional intravenous injection used for confocal imaging. pCLE of the stomach uninfected with Helicobacter pylori was performed in a healthy male employing intravenous administration and local mucosal application of fluorescein. The mucosa of the lower gastric body was biopsied 1 min and 5 min after intravenous administration or local mucosal application of fluorescein, and the distribution of fluorescein in the biopsy samples was examined histologically. Green fluorescence was already observed in the cytoplasm of fundic glandular cells in the biopsied deep mucosa 1 min after local mucosal application of fluorescein. It was also observed in the foveolar lumen and inter-foveolar lamina propria, although it was noted at only a few sites. In the tissue biopsied 5 min after the local mucosal application of fluorescein, green fluorescence was more frequently noted in the cytoplasm of fundic glandular cells than in that 1 min after the local mucosal application of fluorescein, although obvious green fluorescence was not identified in the foveolar lumen or inter-foveolar lamina propria. The distribution of intravenously administered fluorescein in the cytoplasm of fundic glandular cells was also clearly observed similarly to that after local mucosal application of fluorescein. Green fluorescence in more cells was observed in many cells 5 min after intravenous administration compared

  2. Use of Fluorescein Isothiocyanate-Inulin as a Marker for Intestinal Ischemic Injury.

    Science.gov (United States)

    AlKukhun, Abedalrazaq; Caturegli, Giorgio; Munoz-Abraham, Armando Salim; Judeeba, Sami; Patron-Lozano, Roger; Morotti, Raffaella; Rodriguez-Davalos, Manuel I; Geibel, John P

    2017-06-01

    Intestinal ischemia is observed in conditions such as mesenteric ischemia, or during traumatic events such as intestinal transplantation. Intestinal ischemia leads to pathophysiologic disruptions that present as increased fluid secretion into the intestinal lumen. We propose a novel method to detect real-time ischemic injury that is used in an in vitro model applicable to intestinal transplantation. Small intestine segments from rats were procured. The segments were attached to customized perfusion chambers. Both intestines were perfused on the vascular side with a Ringer buffer solution. The experimental buffer solution was bubbled with 100% nitrogen to mimic ischemia. Both lumens were perfused with 3 mL HEPES-Ringer solution containing 50 μM fluorescein isothiocyanate (FITC)-inulin. Intraluminal samples were collected at 15-minute intervals to measure FITC-inulin concentration using a nanofluorospectrophotometer. Intestinal tissue samples were processed and evaluated by a blinded pathologist using the Park/Chiu scoring system for grading intestinal ischemia. Samples collected from the ischemic intestine showed a significant decrease in FITC-inulin fluorescence compared with the control intestine, indicating enhanced fluid secretion. Histopathologic samples from the experimental arm exhibited higher scores of ischemic injury in comparison with the control arm, confirming the FITC-inulin as a correlation to ischemia. Fluorescein isothiocyanate-inulin can be used as a real-time volume marker to monitor the ischemic state of intestinal tissue. A positive correlation between the degree of fluid shift and presence of ischemic injury. The changes in fluorescence signal provide a potential selective method to measure real-time fluid changes inside an intestinal graft to evaluate viability. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Mechanisms of superficial micropunctate corneal staining with sodium fluorescein: the contribution of pooling.

    Science.gov (United States)

    Bandamwar, Kalika L; Garrett, Qian; Papas, Eric B

    2012-04-01

    To establish if sodium fluorescein (SFL) dye accumulation within intercellular spaces on the ocular surface contributes to the appearance of superficial punctate corneal staining. Thirteen subjects bilaterally wore PureVision™ lenses that had been pre-soaked in ReNu MultiPlus® multipurpose solution. After 1h of lens wear, corneal staining with SFL was assessed using a standard slit-lamp technique. Participants who presented with bilateral, corneal staining were selected for further evaluation. A randomly selected eye was rinsed with saline three times. Fellow eyes (control) received no rinsing. After each rinse, the appearance of SFL staining was recorded without any further instillation of the dye. To eliminate any confounding effects of staining due to residual fluorescein in the tear menisci, corneal staining was induced in freshly excised, isolated, rabbit eyes by topical administration of 0.001% PHMB and staining, rinsing and grading were performed as above. Nine out of 13 subjects presented with bilateral diffuse corneal staining (mean grade±SD: 2.4±0.7). The mean staining grades in test and control eyes respectively after each of the three rinses were (1) 2.41±0.41, 2.25±0.69 (p=0.9); (2) 2.34±0.79, 2.1±0.83 (p=0.8); and (3) 1.71±0.65, 1.60±0.79 (p=0.6) there was no significant reduction in staining with rinsing (p>0.05) and no difference was observed between test and control eyes at any sampling-point. Similar observations made in ex vivo rabbit eyes replicated these results. Pooling or accumulation of SFL solution within intercellular spaces does not appear to contribute to the appearance of superficial micropunctate corneal staining. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Molecular Morphology of Pituitary Cells, from Conventional Immunohistochemistry to Fluorescein Imaging

    Directory of Open Access Journals (Sweden)

    R. Yoshiyuki Osamura

    2011-04-01

    Full Text Available In situ hybridization (ISH at the electron microscopic (EM level is essential for elucidating the intracellular distribution and role of mRNA in protein synthesis. EM-ISH is considered to be an important tool for clarifying the intracellular localization of mRNA and the exact site of pituitary hormone synthesis on the rough endoplasmic reticulum. A combined ISH and immunohistochemistry (IHC under EM (EM-ISH&IHC approach has sufficient ultrastructural resolution, and provides two-dimensional images of the subcellular localization of pituitary hormone and its mRNA in a pituitary cell. The advantages of semiconductor nanocrystals (quantum dots, Qdots and confocal laser scanning microscopy (CLSM enable us to obtain three-dimensional images of the subcellular localization of pituitary hormone and its mRNA. Both EM-ISH&IHC and ISH & IHC using Qdots and CLSM are useful for understanding the relationships between protein and mRNA simultaneously in two or three dimensions. CLSM observation of rab3B and SNARE proteins such as SNAP-25 and syntaxin has revealed that both rab3B and SNARE system proteins play important roles and work together as the exocytotic machinery in anterior pituitary cells. Another important issue is the intracellular transport and secretion of pituitary hormone. We have developed an experimental pituitary cell line, GH3 cell, which has growth hormone (GH linked to enhanced yellow fluorescein protein (EYFP. This stable GH3 cell secretes GH linked to EYFP upon stimulation by Ca2+ influx or Ca2+ release from storage. This GH3 cell line is useful for the real-time visualization of the intracellular transport and secretion of GH. These three methods from conventional immunohistochemistry and fluorescein imaging allow us to consecutively visualize the process of transcription, translation, transport and secretion of anterior pituitary hormone.

  5. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  6. MR angiography in tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, Jayantee; Prasad, Sreeram; Maurya, Pradeep K.; Misra, Usha K. (Dept. of Neurology, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India)), Email: drukmisra@rediffmail.com; Kumar, Sunil (Dept. of Radiodiagnosis, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2012-04-15

    Background: Infarctions in tuberculous meningitis (TBM) are common but there is a paucity of studies on MR angiography (MRA). Purpose: To evaluate the pattern and predictors of MRA abnormality in patients with TBM. Material and Methods: Sixty-seven patients with TBM were subjected to clinical, laboratory, magnetic resonance imaging (MRI), and MRA evaluation. The severity of meningitis, focal deficit, CSF findings, and stroke co-morbidities were recorded. Presence of exudates, infarction, hydrocephalous, and tuberculoma on MRI were noted. On intracranial MRA, occlusion or more than 50% narrowing of proximal middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA), and basilar artery were considered abnormal. The MRA abnormality was correlated with clinical, laboratory, and MRI findings. Results: Sixty-seven patients, aged 3-75 years (median 34 years) were included. MRI was abnormal in 61 (91%) patients; basal exudates in 24, hydrocephalous in 23, tuberculoma in 33, and infarction in 40. MRA was abnormal in 34 (50.7%); MCA was most commonly involved (n = 21), followed by PCA (n = 14), ICA (n = 8), ACA (n 5), basilar artery (n = 5), and vertebral and superior cerebellar artery (1 each). One-fourth of the patients had abnormality in both anterior and posterior circulations. MRA abnormality was related to hydrocephalous and infarction; corresponding infarct was present in 61.8% patients; 41.7% patients with abnormal MRA developed infarct at 3 months but none with normal MRA. Conclusion: Half the patients with TBM had MRA abnormality involving both anterior and posterior circulations and 61.8% of them had corresponding infarcts

  7. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  8. Effective selection of hypertensive patients for angiography

    International Nuclear Information System (INIS)

    van der Voorde, F.; Derkx, F.H.M.; Bossuyt, P.M.M.; Segaar, R.W.; de Wind, A.; Pieterman, H.

    1989-01-01

    The authors prospectively observed 373 severe hypertensives with either diastolic blood pressure (BP) ≥ 105 and age ≤ 40, or BP with three drugs ≥ 105 (regardless of age). Excluded were patients who were older than 75 or who had creatinine >400. History, physical examination, and laboratory data were used to identify high-yield criteria for arteriography. All patients underwent angiography as the gold standard; angiography showed 127 unilateral renal artery stenoses, 73 bilateral renal artery stenoses, and 173 (nonstenosed) essential hypertensives. The authors constructed a logistic regression model of height, weight, age, smoking, and hypertension duration, which could be used to identify 90% of stenosed patients with 50% fewer angiographies in the essential hypertensives

  9. Bright new colours: the history and analysis of fluorescein, eosin, erythrosine, rhodamine and some of their derivatives

    NARCIS (Netherlands)

    de Keijzer, M.; van Bommel, M.R.; Kirby, J.

    2017-01-01

    This paper discusses the history, chemical constitution, production, dyeing processes and properties of the hydroxyphthaleins. Important dyes of this dye class are fluorescein, the eosins, phloxines, erythrosines, rose bengals and rhodamines. These dyes were used for textile dyeing and as painting

  10. pH dependence and unsuitability of fluorescein dye as a tracer for pesticide mobility studies in acid soil

    Science.gov (United States)

    Chris Peterson

    2009-01-01

    The mobility of fluorescein and bromide used as tracers in packed soil columns was investigated.Five different soils were used in two application methods: soil surface application and soil incorporation, both of which simulate accepted methods of soil application of termiticides to prevent structural infestation. The...

  11. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  12. Development of a novel fluorescent tag O-2-[aminoethyl]fluorescein for the electrophoretic separation of oligosaccharides

    International Nuclear Information System (INIS)

    Kazarian, Artaches A.; Smith, Jason A.; Hilder, Emily F.; Breadmore, Michael C.; Quirino, Joselito P.; Suttil, James

    2010-01-01

    This study describes the development of a novel fluorescent tag, O-2-[aminoethyl]fluorescein, for the separation of sugars by capillary electrophoresis with fluorescence detection using an argon ion laser. The tag was synthesised using three consecutive steps namely: esterification, alkylation and hydrolysis, specifically designed to offer a flexible way in which to make an assortment of fluorescent tags from cheap and readily available starting reagents (typically less than $1 per g of fluorescent tag). Via this flexible synthetic pathway, O-2-[aminoethyl]fluorescein was designed and synthesised with a spacer group to lower steric effects between the fluorescein backbone and the reducing end of the carbohydrate which were anticipated to improve the reactivity of the tag. The newly synthesised tag, O-2-[aminoethyl]fluorescein was evaluated against structurally similar commercial fluorescent motifs namely fluorescent 5-aminomethylfluorescein and non-fluorescent 5-aminofluorescein. Kinetic studies indicated that O-2-[aminoethyl]fluorescein showed similar labeling efficiencies as 5-aminomethylfluorescein, but were achieved in only 30 min, supporting the notion of improved reactivity of the spacer group. The sensitivity of O-2-[aminoethyl]fluorescein was evaluated using maltoheptaose with a detection limit of 1 nM obtained, which was slightly higher than that of 0.3 nM obtained with 5-aminomethylfluorescein, and was due to its lower quantum yield (0.24) when conjugated to the sugar. The separation performance of the tag was also benchmarked with the two commercial reagents using a range of corn syrup oligosaccharides, from 4 to 10 glucose units, typically found in rice starch. Separations were performed using an electrolyte containing 100 mM boric acid, tris at pH 8.65 as background electrolyte, 30 kV applied voltage, 50 μm I.D. x 40 cm (30 cm effective length) capillary. The novel tag showed better resolution of small oligosaccharides, G3 and G4, than the other two

  13. Transfer of bacteriophage MS2 and fluorescein from N95 filtering facepiece respirators to hands: Measuring fomite potential

    Science.gov (United States)

    Brady, Tyler M.; Strauch, Amanda L.; Almaguer, Claudia M.; Niezgoda, George; Shafer, Ronald E.; Yorio, Patrick L.; Fisher, Edward M.

    2017-01-01

    Contact transmission of pathogens from personal protective equipment is a concern within the healthcare industry. During public health emergency outbreaks, resources become constrained and the reuse of personal protective equipment, such as N95 filtering facepiece respirators, may be needed. This study was designed to characterize the transfer of bacteriophage MS2 and fluorescein between filtering facepiece respirators and the wearer’s hands during three simulated use scenarios. Filtering facepiece respirators were contaminated with MS2 and fluorescein in droplets or droplet nuclei. Thirteen test subjects performed filtering facepiece respirator use scenarios including improper doffing, proper doffing and reuse, and improper doffing and reuse. Fluorescein and MS2 contamination transfer were quantified. The average MS2 transfer from filtering facepiece respirators to the subjects’ hands ranged from 7.6–15.4% and 2.2–2.7% for droplet and droplet nuclei derived contamination, respectively. Handling filtering facepiece respirators contaminated with droplets resulted in higher levels of MS2 transfer compared to droplet nuclei for all use scenarios (p = 0.007). MS2 transfer from droplet contaminated filtering facepiece respirators during improper doffing and reuse was greater than transfer during improper doffing (p = 0.008) and proper doffing and reuse (p = 0.042). Droplet contamination resulted in higher levels of fluorescein transfer compared to droplet nuclei contaminated filtering facepiece respirators for all use scenarios (p = 0.009). Fluorescein transfer was greater for improper doffing and reuse (p = 0.007) from droplet contaminated masks compared to droplet nuclei contaminated filtering facepiece respirators and for improper doffing and reuse when compared improper doffing (p = 0.017) and proper doffing and reuse (p = 0.018) for droplet contaminated filtering facepiece respirators. For droplet nuclei contaminated filtering facepiece respirators, the

  14. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  15. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  16. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  17. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  18. Selective angiography in fifty patients with primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shou-Zhong, Wang; Xing-Rong, Chen; Gong-Xian, Wang

    1983-06-01

    Selective angiography is of great importance in the diagnosis of primary hepatocellular carcinoma. It offers information on the findings, multicentricity, localisation, extension, and type of growth. This paper discusses angiography from the methodical point of view, the findings to be obtained, the types of hepatocellular carcinoma, and the diagnostic efficiency of selective angiography in the evaluation of this type of tumour.

  19. Micro-instillation of fluorescein with an inoculation loop for ocular surface staining in dry eye syndrome.

    Science.gov (United States)

    Courrier, Emilie; Renault, Didier; Kaspi, Mathilde; Marcon, Agathe; Lambert, Victor; Garcin, Thibaud; Chiambaretta, Frederic; Garhofer, Gerhard; Thuret, Gilles; Gain, Philippe

    2018-03-01

    To describe and validate the micro-instillation of fluorescein on the ocular surface by a disposable calibrated inoculation loop to improve corneal and conjunctival staining quality. Accuracy and precision of the volume of 0.5% sodium fluorescein collected by a single use 1 μl-calibrated inoculation loop were measured using a precision balance. Twenty patients (40 eyes) suffering from dry eye syndrome were enrolled in a prospective interventional nonrandomized study. Fluorescein was instilled with the loop, and slit-lamp images were taken within 30 seconds using cobalt blue light with and without a yellow barrier filter. For comparison, after a washout period, the same images were retaken after instillation of one drop of fluorescein from a single-dose unit. The main outcome measure was the staining quality assessed by three experts, blind to the instillation method. Patient discomfort (tolerance, by a questionnaire) was also compared. The mean volume collected by the loop was 1.18 ± 0.12 μl, compared with 33.70 ± 6.10 μl using the single-dose unit. The loop avoided excess dye responsible for unpleasant tearing, masking of lesions and rapid diffusion into the stroma. Micro-instillation greatly improved image quality without losing information. The yellow filter further improved image contrast. Tolerance was excellent. The 1 μl-calibrated inoculation loop is a safe, convenient, inexpensive, disposable, sterile, well-tolerated tool for reproducible micro-instillation of commercial fluorescein. By greatly improving staining quality, it will help standardize assessment of dry eye severity. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Evolution of Choroidal Neovascularization due to Presumed Ocular Histoplasmosis Syndrome on Multimodal Imaging including Optical Coherence Tomography Angiography

    Directory of Open Access Journals (Sweden)

    T. Y. Alvin Liu

    2018-01-01

    Full Text Available A 37-year-old Caucasian woman presented with acute decrease in central vision in her right eye and was found to have subfoveal choroidal neovascularization (CNV due to presumed ocular histoplasmosis syndrome (POHS. Her visual acuity improved from 20/70 to 20/20 at her 6-month follow-up, after 3 consecutive monthly intravitreal bevacizumab injections were initiated at her first visit. Although no CNV activity was seen on fluorescein angiography (FA or spectral-domain optical coherence tomography (SD-OCT at her 2-month, 4-month, and 6-month follow-up visits, persistent flow in the CNV lesion was detected on optical coherence tomography angiography (OCTA. OCTA shows persistent vascular flow as well as changes in vascular flow in CNV lesions associated with POHS, indicating the continued presence of patent vessels and changes in these CNV lesions, even when traditional imaging of the lesion with OCT and FA indicates stability of the lesion with no disease activity. Additional cases with longitudinal follow-up are needed to assess how OCTA should be incorporated into clinical practice.

  1. Challenges and advantages in wide-field optical coherence tomography angiography imaging of the human retinal and choroidal vasculature at 1.7-MHz A-scan rate

    Science.gov (United States)

    Poddar, Raju; Migacz, Justin V.; Schwartz, Daniel M.; Werner, John S.; Gorczynska, Iwona

    2017-10-01

    We present noninvasive, three-dimensional, depth-resolved imaging of human retinal and choroidal blood circulation with a swept-source optical coherence tomography (OCT) system at 1065-nm center wavelength. Motion contrast OCT imaging was performed with the phase-variance OCT angiography method. A Fourier-domain mode-locked light source was used to enable an imaging rate of 1.7 MHz. We experimentally demonstrate the challenges and advantages of wide-field OCT angiography (OCTA). In the discussion, we consider acquisition time, scanning area, scanning density, and their influence on visualization of selected features of the retinal and choroidal vascular networks. The OCTA imaging was performed with a field of view of 16 deg (5 mm×5 mm) and 30 deg (9 mm×9 mm). Data were presented in en face projections generated from single volumes and in en face projection mosaics generated from up to 4 datasets. OCTA imaging at 1.7 MHz A-scan rate was compared with results obtained from a commercial OCTA instrument and with conventional ophthalmic diagnostic methods: fundus photography, fluorescein, and indocyanine green angiography. Comparison of images obtained from all methods is demonstrated using the same eye of a healthy volunteer. For example, imaging of retinal pathology is presented in three cases of advanced age-related macular degeneration.

  2. Magnetic resonance angiography: infrequent anatomic variants

    International Nuclear Information System (INIS)

    Trejo, Mariano; Meli, Francisco; Lambre, Hector; Blessing, Ricardo; Gigy Traynor, Ignacio; Miguez, Victor

    2002-01-01

    We studied through RM angiography (3D TOF) with high magnetic field equipment (1.5 T) different infrequent intracerebral vascular anatomic variants. For their detection we emphasise the value of post-processed images obtained after conventional angiographic sequences. These post-processed images should be included in routine protocols for evaluation of the intracerebral vascular structures. (author)

  3. Hodgkin's disease following thorium dioxide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Gotlieb, A I; Kirk, M E [McGill Univ., Montreal, Quebec (Canada). Dept. of Pathology; Hutchison, J L [Montreal General Hospital, Quebec (Canada)

    1976-09-04

    Hodgkin's disease occurred in a 53-year-old man who, 25 years previously, had undergone cerebral angiography, for which thorium dioxide suspension (Thorotrast) was used. Deposits of thorium dioxide were noted in reticuloendothelial cells in various locations. An association between thorium dioxide administration and the subsequent development of malignant tumours and neoplastic hematologic disorders has previously been reported.

  4. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  5. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  6. Magnetic resonance angiography in meningovascular syphilis

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, J [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Soriano, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Zubieta, J L [Servicio de Neuroradiologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Delgado, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Villanueva, J A [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain)

    1994-04-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  7. Vascular anatomy in angiography for magnetic resonance

    International Nuclear Information System (INIS)

    Charry Lopez, Marco Luciano; Rivera Gomez, Juan Enrique

    1998-01-01

    A review of basic anatomical concepts and main variants, as well as some anatomical anomalies of the central nervous system vascularity, these concepts are considered essential for the interpretation of magnetic resonance angiography with time-of-flight (TOF) and phase-contrast (PC) methods

  8. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  9. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  10. Conventional cerebral angiography in occlusive cerebrovascular disease

    International Nuclear Information System (INIS)

    Caplan, L.R.; Wolpert, S.M.

    1987-01-01

    Treatment of the patient with occlusive vascular lesions of the extracranial and intracranial arteries will depend on the location, nature, and severity of the vascular disease and the general and neurologic condition of the patient. At present, standard angiography is the best method of opacifying the vascular system to gain critical information about the vascular lesion

  11. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  12. Intraarterial tolazoline in angiography of the foot

    International Nuclear Information System (INIS)

    Neubauer, B.

    1978-01-01

    Foot angiography was performed in 32 diabetic patients with and without intraarterial injection of tolazoline (Priscoline). The angiographic quality was improved with tolazoline, manifested as an increased flow rate with acceleration of the arteriovenous transit time, a higher incidence of complete arterial filling with contrast medium in clinically important regions, and considerably longer arterial segments demonstrated within defined regions of measurement. (Auth.)

  13. Angiography and angiotherapy of gastrointestinal tract bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, R.; Grassot, A.; Souchon, R.

    1982-03-01

    In selected patients with upper and lower gastrointestinal hemorrhage there is an indication for angiography. Vasoconstrictive drugs or embolization materials can be submitted through the catheter to stop the hemorrhage (angiotherapy). 81 patients were diagnosed by this method. Treatment through the angiographic catheter followed the diagnostic procedure in 41 cases. The hemorrhage was controlled in 36 patients.

  14. Digital subtraction angiography: first 900 cases

    International Nuclear Information System (INIS)

    Rodgers, H.

    1984-01-01

    The diagnostic technique of digital subtraction angiography (DSA) is briefly outlined. The operational and technical experiences with a DR-960 DSA system used in the examination of the first 900 cases at St. Thomas' Hospital, London are described. (U.K.)

  15. Magnetic resonance angiography in meningovascular syphilis

    International Nuclear Information System (INIS)

    Gallego, J.; Soriano, G.; Zubieta, J.L.; Delgado, G.; Villanueva, J.A.

    1994-01-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  16. Two new contrast media in coronary angiography

    International Nuclear Information System (INIS)

    Selin, K.; Bjoerk, L.

    1983-01-01

    Amipaque, ioxaglic acid and Isopaque Coronar 300 were compared in a double blind investigation of coronary angiography in patients with ischemic heart disease. Amipaque affected systolic blood pressure and ECG less than the other contrast media. Ioxaglic acid appeared to give more ST and T changes than Isopaque Coronar. (Auth.)

  17. On the system of cine-angiography

    International Nuclear Information System (INIS)

    Wakamatsu, Koji; Togi, Hideaki; Yokoyama, Hironori

    1979-01-01

    National Institute of Circulatory Disease Centre have four angiography apparatuses which deal with more than 80 cases of cerebral blood vessel and 100 cases of heart blood vessel each month. Most of the angiography is cine-photography. Five more angiography apparatuses are expected to be operated in operation and RI examination rooms in the future. The problems on cine-angiography system were discussed as follows: (1) The proper dose must be chosen in order to obtain good quality of cine-images. (2) The cine resolution depends much on dose. (3) The lower X-ray tube voltage can give better contrast. (4) Suitable capacity for an X-ray tube is over 60 kW at 2 sec rating. (5) Cine-autophotography requires rapid response and a circuit for lock. (6) Influence of side scattering can be solved by a blanking circuit in biplane cine-photography. (7) Self-developing is desirable to improve the quality of cine-images. (Kobatake, H.)

  18. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  19. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  20. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  1. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  2. Fluorescein diacetate for determination of cell viability in tissue-engineered skin.

    Science.gov (United States)

    Armour, Alexis D; Powell, Heather M; Boyce, Steven T

    2008-03-01

    Assurance of the quality of cultured skin substitutes (CSSs) currently relies on representative histology and determination of surface hydration, which provide limited sampling at selected points. To evaluate uniformity of cell density on the collagen matrices before clinical use, a field assessment of cell viability is advantageous. This study aimed to develop a field measure of cell viability in CSSs in vitro using fluorescein diacetate (FdA). CSSs were stained 3 days after keratinocyte inoculation using 0.04 mg/mL FdA followed by exposure to 366 nm of ultraviolet light. CSS fluorescence quantified using Metamorph image analysis was correlated with inoculation density, 3-(4,5-dimethylthiazol-2-Yl)-2,5-diphenyltetrazolium bromide (MTT) values and histology of corresponding biopsies. CSS fluorescence correlated significantly with inoculation density (p < 0.001) and MTT values (p < 0.001) of biopsies collected immediately after FdA staining. Fluorescence at day 3 also predicted day 10 MTT values. No toxicity was detected in CSSs, and normal in vitro and in vivo histology was demonstrated after FdA exposure. In conclusion, measurement of intracellular fluorescence with FdA allows for the early, comprehensive measurement of cellular distributions and viability in engineered skin and may therefore facilitate quality assurance.

  3. Retinal fluorescein contrast arrival time of young patients with the hepatosplenic form of the Schistosomiasis mansoni

    Directory of Open Access Journals (Sweden)

    Ana Catarina Delgado de Souza

    2002-10-01

    Full Text Available Schistosoma mansoni is responsible for lesions that can alter the hemodinamic of the portal venous circulation, lung arterial and venous sistemic systems. Therefore, hemodinamic changes in the ocular circulation of mansonic schistosomotic patients with portal hypertension and hepatofugal venous blood flow is also probable. The purpose of this study was to determine the fluorescein contrast arrival time at the retina of young patients with the hepatosplenic form of schistosomiasis, clinically and surgically treated. The control group included 36 non schistosomotic patients, mean age of 17.3 years, and the case group was represented by 25 schistosomotic patients, mean age of 18.2 years, who were cared for at The University Hospital (Federal University of Pernambuco, Brazil, from 1990 to 2001. They underwent digital angiofluoresceinography and were evaluated for the contrast arrival time at the early retinal venous phase of the exam. Both groups were ophthalmologically examined at the same hospital (Altino Ventura Foundation, Recife, Brazil, using the same technique. There was retardation of the retinal contrast arrival time equal or more than 70 sec in the eyes of three schistosomotic patients (12% and in none of the control group, however, the mean contrast arrival time between the two groups were not statistically different. These findings lend support to the hypothesis that there could be a delay of the eye venous blood flow drainage.

  4. Fluorescent Staining of Tea Pathogenic Fungi in Tea Leaves Using Fluorescein-labeled Lectin

    Science.gov (United States)

    Yamada, Kengo; Yoshida, Katsuyuki; Sonoda, Ryoichi

    Fluorochrome-labeled lectin, fluorescein conjugated wheat germ agglutinin (F-WGA) was applied to stain tea pathogenic fungi in tea leaf tissue. Infected leaves were fixed and decolorized with a mixture of ethanol and acetic acid, and cleared with 10% KOH for whole mount before staining with F-WGA. Hyphae of Pestalotiopsis longiseta, Pseudocercospora ocellata, Botrytis cinerea and Colletotrichum theae-sinensis fluoresced brightly in whole mount and sectioned samples of infected leaf tissue. In browned tissue, hyphae did not fluoresce frequently in whole mount sample. Autofluorescence of leaf tissue was strong in browned tissue of sections, it was removed by 10% KOH treatment before staining. Penetration hyphae of C. theae-sinensis in cell wall of trichome and hyphae in basal part of trichome did not fluoresced frequently. In whole mount samples of tea leaf infected with Exobasidium vexans and E. reticulatum, hymenia appeared on leaf surface fluoresced, but hyphae in leaf tissue did not fluoresce. In sectioned samples, hyphae fluoresced brightly when sections were treated with 10% KOH before staining.

  5. Dual fluorescence and laser emissions from fluorescein-Na and eosin-B

    International Nuclear Information System (INIS)

    Math, N.N.; Naik, L.R.; Suresh, H.M.; Inamdar, S.R.

    2006-01-01

    Dual laser emissions were observed from fluorescein-Na and eosin-B in ethanolic solutions individually in the concentration range from 10 -2 to 10 -3 mol dm -3 under N 2 laser excitation. The first compound was found to lase at two distinct regions with wavelength maxima around 540, 550 nm, while the second one around 558, 574 nm. Steady-state absorption, fluorescence excitation, fluorescence polarization, fluorescence emission and decays of the dyes in various solvents under varying conditions of excitation and detection systems were carried out to identify the nature of the emitting species responsible for laser emissions in two distinct regions. Both the dyes exhibited concentration and excitation wavelength dependence of fluorescence and the effects were found to be more pronounced in binary solution. The fluorescence decays of dyes were monoexponential in ethanol, while in some other solvents used, the decays showed biexponential behavior. The absorption and excitation studies using thin layers of solutions revealed the formation of dimers with the dye concentration around 1x10 -3 mol dm -3 . Fluorescence polarization and decay studies confirmed the presence of dimers. The two laser bands observed in the shorter and longer wavelengths were respectively ascribed to monomeric and dimeric species

  6. Dual fluorescence and laser emissions from fluorescein-Na and eosin-B

    Energy Technology Data Exchange (ETDEWEB)

    Math, N.N. [Laser Spectroscopy (DRDO/KU) Programme, Department of Physics, Karnatak University, Dharwad 580 003 (India)]. E-mail: nnm31@rediffmail.com; Naik, L.R. [Laser Spectroscopy (DRDO/KU) Programme, Department of Physics, Karnatak University, Dharwad 580 003 (India); Suresh, H.M. [Laser Spectroscopy (DRDO/KU) Programme, Department of Physics, Karnatak University, Dharwad 580 003 (India); Inamdar, S.R. [Laser Spectroscopy (DRDO/KU) Programme, Department of Physics, Karnatak University, Dharwad 580 003 (India)

    2006-12-15

    Dual laser emissions were observed from fluorescein-Na and eosin-B in ethanolic solutions individually in the concentration range from 10{sup -2} to 10{sup -3} mol dm{sup -3} under N{sub 2} laser excitation. The first compound was found to lase at two distinct regions with wavelength maxima around 540, 550 nm, while the second one around 558, 574 nm. Steady-state absorption, fluorescence excitation, fluorescence polarization, fluorescence emission and decays of the dyes in various solvents under varying conditions of excitation and detection systems were carried out to identify the nature of the emitting species responsible for laser emissions in two distinct regions. Both the dyes exhibited concentration and excitation wavelength dependence of fluorescence and the effects were found to be more pronounced in binary solution. The fluorescence decays of dyes were monoexponential in ethanol, while in some other solvents used, the decays showed biexponential behavior. The absorption and excitation studies using thin layers of solutions revealed the formation of dimers with the dye concentration around 1x10{sup -3} mol dm{sup -3}. Fluorescence polarization and decay studies confirmed the presence of dimers. The two laser bands observed in the shorter and longer wavelengths were respectively ascribed to monomeric and dimeric species.

  7. Thermally activated delayed fluorescence of fluorescein derivative for time-resolved and confocal fluorescence imaging.

    Science.gov (United States)

    Xiong, Xiaoqing; Song, Fengling; Wang, Jingyun; Zhang, Yukang; Xue, Yingying; Sun, Liangliang; Jiang, Na; Gao, Pan; Tian, Lu; Peng, Xiaojun

    2014-07-09

    Compared with fluorescence imaging utilizing fluorophores whose lifetimes are in the order of nanoseconds, time-resolved fluorescence microscopy has more advantages in monitoring target fluorescence. In this work, compound DCF-MPYM, which is based on a fluorescein derivative, showed long-lived luminescence (22.11 μs in deaerated ethanol) and was used in time-resolved fluorescence imaging in living cells. Both nanosecond time-resolved transient difference absorption spectra and time-correlated single-photon counting (TCSPC) were employed to explain the long lifetime of the compound, which is rare in pure organic fluorophores without rare earth metals and heavy atoms. A mechanism of thermally activated delayed fluorescence (TADF) that considers the long wavelength fluorescence, large Stokes shift, and long-lived triplet state of DCF-MPYM was proposed. The energy gap (ΔEST) of DCF-MPYM between the singlet and triplet state was determined to be 28.36 meV by the decay rate of DF as a function of temperature. The ΔE(ST) was small enough to allow efficient intersystem crossing (ISC) and reverse ISC, leading to efficient TADF at room temperature. The straightforward synthesis of DCF-MPYM and wide availability of its starting materials contribute to the excellent potential of the compound to replace luminescent lanthanide complexes in future time-resolved imaging technologies.

  8. pH-sensitive intracellular photoluminescence of carbon nanotube-fluorescein conjugates in human ovarian cancer cells

    International Nuclear Information System (INIS)

    Chen, M T; Ishikawa, F N; Gundersen, M A; Gomez, L M; Vernier, P T; Zhou, C

    2009-01-01

    To add to the understanding of the properties of functionalized carbon nanotubes in biological applications, we report a monotonic pH sensitivity of the intracellular fluorescence emission of single-walled carbon nanotube-fluorescein carbazide (SWCNT-FC) conjugates in human ovarian cancer cells. Light-stimulated intracellular hydrolysis of the amide linkage and localized intracellular pH changes are proposed as mechanisms. SWCNT-FC conjugates may serve as intracellular pH sensors.

  9. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  10. Angiography of histopathologic variants of synovial sarcoma

    International Nuclear Information System (INIS)

    Lois, J.F.; Fischer, H.J.; Mirra, J.M.; Gomes, A.S.; California Univ., Los Angeles

    1986-01-01

    Synovial sarcomas are rare soft tissue tumors which histopathologically can be divided into monophasic, biphasic and mixed variants. As part of a protocol for intra-arterial chemotherapy 12 patients with biopsy proven synovial sarcoma underwent angiography. The angiograms on these patients were reviewed to determine whether synovial sarcomas and their variants demonstrated a characteristic angiographic appearance. Synovial sarcomas appeared angiographically as soft tissue masses which showed a fine network of tumor vessels with an inhomogeneous capillary blush. Their degree of vascularity varied according to their histopathology. Monophasic synovial sarcomas demonstrated in general a higher degree of neovascularity than the biphasic form. This finding was also suggested by histopathologic analysis of the vessels in the tumor. Although angiography did not show a distinctive vascular pattern it may be useful to evaluate tumor size and vascularity. (orig.)

  11. Clinical application of magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Murakami, Akihiko; Onoe, Teruyuki; Kodera, Akifumi; Ohtsuki, Tetsuya; Shiomi, Akio; Ida, Masaaki; Sawada, Takahisa

    1999-01-01

    We performed the magnetic resonance coronary angiography (MRCA) in the cases which underwent coronary angiography (CAG) and obtained images were compared. Lesion with significant constriction more than 75% on CAG were determined as abnormal findings on MRCA, however, lesions with about 50% constriction were as the normal findings. On the assessment of the re-constriction after PTCA, the changes in signal were found in about half of cases. This may come from the contribution of flexion lesions, the difficulty to assess moderate constriction after PTCA, etc. For the anomalous aortic origin of coronary artery, peripheral large vessels could be simultaneously imaged by MRCA and be also assessed among their clear spatial relationship. Although MRCA has some problems on the assessment for flexion or moderate constriction, these results suggested that MRCA is useful to clinical application as the non-invasive examination. (K.H.)

  12. Angiography in the region of the foot

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E.

    1984-06-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg.

  13. Angiography in the region of the foot

    International Nuclear Information System (INIS)

    Zeitler, E.

    1984-01-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg. (orig.) [de

  14. Fluorescein-methotrexate transport in dogfish shark (Squalus acanthias) choroid plexus.

    Science.gov (United States)

    Baehr, Carsten H; Fricker, Gert; Miller, David S

    2006-08-01

    The vertebrate choroid plexus removes potentially toxic metabolites and xenobiotics from cerebrospinal fluid (CSF) to blood for subsequent excretion in urine and bile. We used confocal microscopy and quantitative image analysis to characterize the mechanisms driving transport of the large organic anion, fluorescein-methotrexate (FL-MTX), from bath (CSF-side) to blood vessels in intact lateral choroid plexus from dogfish shark, Squalus acanthias, an evolutionarily ancient vertebrate. With 2 microM FL-MTX in the bath, steady-state fluorescence in the subepithelium/vascular space exceeded bath levels by 5- to 10-fold, and fluorescence in the epithelial cells was slightly below bath levels. FL-MTX accumulation in both tissue compartments was reduced by NaCN, Na removal, and ouabain, but not by a 10-fold increase in medium K. Certain organic anions, e.g., probenecid, MTX, and taurocholate, reduced FL-MTX accumulation in both tissue compartments; p-aminohippurate and estrone sulfate reduced subepithelial/vascular accumulation, but not cellular accumulation. At low concentrations, digoxin, leukotriene C4, and MK-571 reduced fluorescence in the subepithelium/vascular space while increasing cellular fluorescence, indicating preferential inhibition of efflux over uptake. In the presence of 10 microM digoxin (reduced efflux, enhanced cellular accumulation), cellular FL-MTX accumulation was specific, concentrative, and Na dependent. Thus transepithelial FL-MTX transport involved the following two carrier-mediated steps: electroneutral, Na-dependent uptake at the apical membrane and electroneutral efflux at the basolateral membrane. Finally, FL-MTX accumulation in both tissue compartments was reduced by phorbol ester and increased by forskolin, indicating antagonistic modulation by protein kinase C and protein kinase A.

  15. Interactions of Fluorescein Dye with Spherical and Star Shaped Gold Nanoparticles.

    Science.gov (United States)

    Pal, Gopa Dutta; Paul, Somnath; Bardhan, Munmun; Ganguly, Tapan

    2018-04-01

    UV-vis absorption, FT-IR, steady state fluorescence and fluorescence lifetime measurements were made on Fluorescein dye (Fl dye) molecules in presence of gold nanoparticles of different morphologies: spherical gold nanoparticles (GNP) and star shaped gold nanoparticles (GNS). The experimental observations demonstrate that Fl dye molecules form dimers when adsorbed on nanosurface of spherical gold particles. On the other hand possibly due to lack of adsorption on the surface of GNS the dye molecules were unable to form dimers. The projected tips on the surface of GNS may possibly hinder the dyes to adsorb on the surface of this nanoparticle. From the spectral analysis and measurements of thermodynamic parameters it is inferred that two different types of ground state interactions occur between Fl-dye-GNP and Fl dye-GNS systems. Both the observed negative values of the thermodynamic parameters ΔH and ΔS in the case of the former system predict the possibility of occurrences of hydrogen bonding interactions between two neighboring Fl dye molecules when adsorbed on the nanosurface of GNP. On the other hand in Fl dye-GNS system electrostatic interactions appear to occur, as evidenced from negative ΔH and positive value of ΔS, between the positive charges residing on the tips of the nanoparticles and anionic form of Fl dye. It has been concluded that as the adsorption of organic dyes on solid surfaces is prerequisite for the degradation of dye pollutants, the present experimental observations demonstrate that GNP could be used as a better candidate than GNS in degradation mechanism of the xanthenes dyes.

  16. Ternary Interactions and Energy Transfer between Fluorescein Isothiocyanate, Adenosine Triphosphate, and Graphene Oxide Nanocarriers.

    Science.gov (United States)

    Ratajczak, Katarzyna; Stobiecka, Magdalena

    2017-07-20

    The interactions of fluorescent probes and biomolecules with nanocarriers are of key importance to the emerging targeted drug delivery systems. Graphene oxide nanosheets (GONs) as the nanocarriers offer biocompatibility and robust drug binding capacity. The interactions of GONs with fluorophores lead to strong fluorescence quenching, which may interfere with fluorescence bioimaging and biodetection. Herein, we report on the interactions and energy transfers in a model ternary system: GONs-FITC-ATP, where FITC is a model fluorophore (fluorescein isothiocyanate) and ATP is a common biomolecule (adenosine-5'-triphosphate). We have found that FITC fluorescence is considerably quenched by ATP (the quenching constant K SV = 113 ± 22 M -1 ). The temperature coefficient of K SV is positive (α T = 4.15 M -1 deg -1 ). The detailed analysis of a model for internal self-quenching of FITC indicates that the temperature dependence of the net quenching efficiency η for the FITC-ATP pair is dominated by FITC internal self-quenching modes with their contribution estimated at 79%. The quenching of FITC by GONs is much stronger (K SV = 598 ± 29 M -1 ) than that of FITC-ATP and is associated with the formation of supramolecular assemblies bound with hydrogen bonding and π-π stacking interactions. For the analysis of the complex behavior of the ternary system GONs-FITC-ATP, a model of chemisorption of ATP on GONs, with partial blocking of FITC quenching, has been developed. Our results indicate that ATP acts as a moderator for FITC quenching by GONs. The interactions between ATP, FITC, and GONs have been corroborated using molecular dynamics and quantum mechanical calculations.

  17. Detection of retinal capillary nonperfusion in fundus fluorescein angiogram of diabetic retinopathy.

    Science.gov (United States)

    Rasta, Seyed Hossein; Nikfarjam, Shima; Javadzadeh, Alireza

    2015-01-01

    Retinal capillary nonperfusion (CNP) is one of the retinal vascular diseases in diabetic retinopathy (DR) patients. As there is no comprehensive detection technique to recognize CNP areas, we proposed a different method for computing detection of ischemic retina, non-perfused (NP) regions, in fundus fluorescein angiogram (FFA) images. Whilst major vessels appear as ridges, non-perfused areas are usually observed as ponds that are surrounded by healthy capillaries in FFA images. A new technique using homomorphic filtering to correct light illumination and detect the ponds surrounded in healthy capillaries on FFA images was designed and applied on DR fundus images. These images were acquired from the diabetic patients who had referred to the Nikookari hospital and were diagnosed for diabetic retinopathy during one year. Our strategy was screening the whole image with a fixed window size, which is small enough to enclose areas with identified topographic characteristics. To discard false nominees, we also performed a thresholding operation on the screen and marked images. To validate its performance we applied our detection algorithm on 41 FFA diabetic retinopathy fundus images in which the CNP areas were manually delineated by three clinical experts. Lesions were found as smooth regions with very high uniformity, low entropy, and small intensity variations in FFA images. The results of automated detection method were compared with manually marked CNP areas so achieved sensitivity of 81%, specificity of 78%, and accuracy of 91%.The result was present as a Receiver operating character (ROC) curve, which has an area under the curve (AUC) of 0.796 with 95% confidence intervals. This technique introduced a new automated detection algorithm to recognize non-perfusion lesions on FFA. This has potential to assist detecting and managing of ischemic retina and may be incorporated into automated grading diabetic retinopathy structures.

  18. Angiography and interventional radiology of the kidneys

    International Nuclear Information System (INIS)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W.

    1999-01-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  19. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  20. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  1. Magnetic resonance angiography for the head and neck region

    International Nuclear Information System (INIS)

    Aschenbach, R.; Esser, D.

    2004-01-01

    Magnetic resonance angiography is a noninvasive method in vascular imaging using noncontrast- enhanced and contrast-enhanced techniques. The contrast media used in contrast- enhanced magnetic resonance angiography are different from the X-ray contrast media and do not affect the thyroid gland or renal function. In detecting hypervascularized lesions in the head and neck, contrast-enhanced magnetic resonance angiography is the method of choice, which provides an acceptable quality in comparison to digital subtraction angiography. Future developments in magnetic resonance imaging techniques will cause a wider use of magnetic resonance angiography, especially in head and neck imaging. Digital subtraction angiography should therefore only be used in problem cases and for preoperative embolization [de

  2. Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography

    International Nuclear Information System (INIS)

    Hauenstein, H.K.; Roeren, T.; Schlosser, V.; Urbani, B.

    1985-01-01

    Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography. Intraarterial DSA is a suitable method for early postoperative control of coronary artery bypass grafts. Small quantities of contrast media with low iodine content are injected into the aortic root. Investigations can be carried out with a routine fluoroscopic and digital equipment; additional cine-technique and analogue memory disc are not necessary. At an image rate of 3/s the bypass anastomoses can be exactly visualized in 75%, whereas diagnostic information was not sufficient in only 4% of all cases. The use of modern F-5-catheters and the nonselective injection make this method a less invasive alternative to coronary angiography. It is paticularly useful in evaluation of short- and long-term results. (orig.) [de

  3. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  4. 眼底荧光造影检查对筛检糖尿病眼底病变的临床价值%Fundus Fluorescence Angiography Revealed the Clinical Value of Screening Diabetic Retinal Pathological Changes

    Institute of Scientific and Technical Information of China (English)

    王克

    2016-01-01

    Objective To explore the application value of fundus fluorescein angiography in screening of diabetic retinopa-thy. Methods Convenient selection who were admitted to our hospital in January 2013 to January 2016 By ophthalmoscopy and fundus fluorescence angiography 78 cases (156 eyes) in patients with diabetes mellitus retinopathy screening, according to Dr staging criteria for diagnosis of diabetic retinopathy staging, and thus as the foundation to give guidance of treatment. Results The detection rate of fundus fluorescein angiography in diabetic retinopathy (82.50%) was higher than that in the fundus examination (67.31%). The difference was statistically significant (P< 0.05). DR stage I period of 47 eyes (30.1%). II phase 29 eyes(18.6%), III phase 25 eyes(16%), IV phase 17 eyes(10.9%), V phase 7 eyes(4.5%), VI phase 3 eyes (1.9%). Conclusion The detection rate of fundus fluorescein angiography in diabetic retinopathy is high, which can be used as an important reference index to guide the treatment of ocular fundus diseases.%目的:探讨眼底荧光造影检查在糖尿病眼底病变筛查中的应用价值。方法方便选取2013年1月—2016年1月以眼底镜和眼底荧光造影检查该院收治的78例(156眼)糖尿病患者进行眼底病变筛查,依DR分期标准对筛查出的糖尿病视网膜病变进行分期,并以此为基础给予患者治疗指导。结果眼底荧光造影对糖尿病眼底病变的检出率显(82.50%)著高于眼底镜下检查(67.31%)。比较差异有统计学意义(P﹤0.05)。 DR分期I期47眼(30.1%)。 II期29眼(18.6%),III期25眼(16.0%),IV期17眼(10.9%),V期7眼(4.5%),VI期3眼(1.9%)。结论以眼底荧光造影筛查糖尿病眼底病变检出率高,可作为指导眼底病变治疗的重要参考指标在临床推广使用。

  5. Prospective comparison of MR angiography and color duplex US with conventional angiography for peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Mulligan, S.A.; Matsuda, T.; Lanzer, P.; Gross, G.; Routh, W.; Keller, F.; Koslin, D.B.; Berland, L.; Fields, M.; Doyle, M.; Cranney, G.; Lee, J.; Pohost, G.

    1990-01-01

    This paper evaluates color Doppler US (CDUS) and MR angiographic (MRA) assessment of peripheral vascular disease of the lower extremities, using blinded prospective comparison with conventional angiography. Conventional angiography, two-dimensional inflow MRA, and CDUS were performed in 12 patients. Four diagnostic categories were used to grade arterial lesions by evaluating peak velocity. Revascularization interventions were planned by the vascular surgeon, blinded from the imaging method utilized and from data derived from CDUS, MRA, and conventional angiography

  6. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  7. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  8. Angiography and interventional radiology of the kidneys; Angiographie und interventionelle Radiologie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W. [Heidelberg Univ. (Germany). Abt. Radiodiagnostik

    1999-05-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  9. Myocardial perfusion imaging by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kadowaki, Hiroyuki; Ishikawa, Kinji; Ogai, Toshihiro; Katori, Ryo

    1986-01-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; 1) at the R wave of the electrocardiogram, 2) 100 msec before the R wave, and 3) 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery. In all patients with anterior myocardial infarction, low perfusion was observed at the infarcted portion compared to the non-infarcted myocardium. In patients with inferior myocardial infarction, this low perfusion area was not observed because right coronary angiography was not subjected to DSA in this study. (J.P.N.)

  10. Assessment of anemia during CT pulmonary angiography

    International Nuclear Information System (INIS)

    Jung, Caroline; Groth, Michael; Bley, Thorsten A.; Henes, Frank O.; Treszl, András; Adam, Gerhard; Bannas, Peter

    2012-01-01

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  11. Assessment of anemia during CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Caroline, E-mail: cjung@uke.de [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Groth, Michael; Bley, Thorsten A.; Henes, Frank O. [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Treszl, András [Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany)

    2012-12-15

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  12. Striatocapsular infarction: MRI and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Croisille, P. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Turjman, F. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Croisile, B. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Tournut, P. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Laharotte, J.C. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Aimard, G. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Trillet, M. (Dept. of Neurology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Duquesnel, J. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre Wertheimer, Lyon (France)); Froment, J.C. (Dept. of Neuroradiology, Hopital Neurologique et Neurochirurgical Pierre

    1994-08-01

    We present a case of left striatocapsular infarction manifest clinically as a transient right hemiparesis. MRI showed a left striatocapsular infarct. Striatocapsular infarction, unlike lacunar infarction, is often associated with occlusive disease of the carotid artery. In order to screen the carotid vessels, cervical MR angiography (MRA) was performed during the same examination, demonstrating a left internal carotid artery occlusion, confirmed by contrast arteriography. MRA, a noninvasive modality, can be a useful adjunct to MRI, when diagnostic information concerning the cervical carotid artery is needed. (orig.)

  13. Digital subtraction angiography in cardiac diseases

    International Nuclear Information System (INIS)

    Choi, Deuk Lin; Kim, Ki Jeong

    1986-01-01

    DSA was done in 133 examinations of 128 patients during 2 years consist of 9 examination of IV DSA and 124 examination of selective cardiac DSA after cardiac catheterization. Open heart surgery was performed in 90 patients and 12 patients showed discrepancy between pre-and post operative diagnosis, showing a total 86.7% of diagnostic accuracy with DSA. We experienced the significant reduction in dose of contrast media, 30-40% of dose of conventional cardiac angiography. It is concluded that DSA is useful in the evaluation of septal defects, valvular disease and other congenital heart disease. DSA is an accurate simple and safe method in evaluating of cardiac diseases.

  14. Quantitative angiography methods for bifurcation lesions

    DEFF Research Database (Denmark)

    Collet, Carlos; Onuma, Yoshinobu; Cavalcante, Rafael

    2017-01-01

    Bifurcation lesions represent one of the most challenging lesion subsets in interventional cardiology. The European Bifurcation Club (EBC) is an academic consortium whose goal has been to assess and recommend the appropriate strategies to manage bifurcation lesions. The quantitative coronary...... angiography (QCA) methods for the evaluation of bifurcation lesions have been subject to extensive research. Single-vessel QCA has been shown to be inaccurate for the assessment of bifurcation lesion dimensions. For this reason, dedicated bifurcation software has been developed and validated. These software...

  15. Miniaturization of catheter systems for angiography

    International Nuclear Information System (INIS)

    Hawkins, I.F. Jr.; Akins, E.W.

    1988-01-01

    The authors discuss the use of small catheters and needles in angiography and interventional procedures to improve the quality of the procedures and increase the success rate and safety. This philosophy was initially poorly received, both by operators and by industry; however, more recently microtechniques have become more acceptable primarily because of the changing economic climate requiring procedures with shorter or no hospitalization time. Since 1970, the authors have performed well over 10,000 angiographic procedures using 5 French catheters, or smaller. During the last 12 years, they have used almost exclusively 4 French catheters, primarily with standard filming techniques which have resulted in no thrombosed arteries, or significant hematoma formation

  16. Radiation exposure and protection during angiography

    Energy Technology Data Exchange (ETDEWEB)

    Biazzi, L; Garbagna, P [Pavia Univ. (Italy)

    1979-05-01

    The authors describe the radiological techniques during angiography examinations in their hospital. For every technique they measured the radiation exposure and dose to the staff of doctors, assistants and nurses in their standard positions in the room and the radiation dose at various points on their bodies. The results are critically discussed and alternative protection devices are analysed, since there are many difficulties concerning the employ of usual radiation protection systems. Cardiologists, above all, are given some recommendations to reduce radiation exposure without prejudicing the exam results.

  17. Pain and hemodynamic effects in aortofemoral angiography

    International Nuclear Information System (INIS)

    Nyman, U.; Nilsson, P.; Westergren, A.

    1982-01-01

    Two new contrast media, iohexol (non-ionic monomer) and ioxaglate (monoacidic dimer), were compared with the non-ionic metrizamide during aortofemoral angiography in a single blind randomized trial in 2 groups of patients with 20 in each. The degree of heat and pain produced by iohexol and ioxaglate did not differ significantly from that produced by metrizamide, while subsequent injections of metrizoate caused significantly more heat and pain. The hemodynamic effects recorded in 10 patients in each group showed that iohexol and ioxaglate induced a decrease in vascular resistance, decrease in blood pressure and increase in heart rate not differing significantly from that induced by metrizamide. (Auth.)

  18. Radiation exposure and protection during angiography

    International Nuclear Information System (INIS)

    Biazzi, L.; Garbagna, P.

    1979-01-01

    The authors describe the radiological techniques during angiography examinations in their hospital. For every technique they measured the radiation exposure and dose to the staff of doctors, assistants and nurses in their standard positions in the room and the radiation dose at various points on their bodies. The results are critically discussed and alternative protection devices are analysed, since there are many difficulties concerning the employ of usual radiation protection systems. Cardiologists, above all, are given some recomandations to reduce radiation exposure without prejudicing the exam results [fr

  19. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  20. Determining the safety and suitability of fluorescein dye for characterization of skin ulcerations in cultured Nile tilapia (Oreochromis niloticus and African sharptooth catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    Mai D. Ibrahem

    2010-10-01

    Full Text Available There is a need to identify the presence of lesions in fish skin as soon as they erupt. Fish skin lesions are either macroscopic (can be visualized by the naked eye or microscopic (difficult to detect with the naked eye. Skin wounds resulting in loss of the epithelium (superficial or deep ulcers are serious as they may interfere with osmoregulation and open portals for opportunistic pathogens. Herein, we report on the use of a fluorescein dye for the detection of skin ulcers that cannot be seen by the naked eye. Due to their importance in aquaculture endeavors in Egypt, this study focused on two indigenous species, the Nile tilapia (Oreochromis niloticus and the scale-less African sharptooth catfish (Clarias gariepinus. Fluorescein dye was tested for safety to fish without interfering with microbiological analysis. Parallel to the use of the flourescein dye, the detected ulcers were examined for the presence of bacteria or tissue alterations. Further, we experimentally induced the formation of skin ulcers in O. niloticus physically or by injecting Aeromons hydrophila, and then assessed the utility of fluorescein dye in detecting the induced skin lesions. Results obtained in this study demonstrated that fluorescein dye application is harmless to Nile tilapia at concentrations up to 0.5 mg fluorescein/ml water for up to 15 min. Indeed, a low dose of fluorescein (0.10 mg/ml for 5 min could identify very minute skin abrasions. We highly recommend the use of fluorescein dye for the evaluation of skin health in farmed fish species and the visualization of minute skin abrasions.

  1. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  2. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  3. Magnetic resonance angiography of arteriovenous malformation in the thalamus

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    A comparative study of magnetic resonance angiography and conventional angiography of arteriovenous malformation in the thalamus showed that both methods clearly visualized the feeding arteries: perforating branches of the posterior cerebral artery, posterior choroidal artery and lenticulostriate artery. Draining veins such as the internal cerebral vein were also demonstrated well. (author).

  4. Correlation of angiography and MR imaging in cerebral vasculitis

    International Nuclear Information System (INIS)

    Cloft, H.J.; Phillips, C.D.; Dix, J.E.; McNulty, B.C.; Kallmes, D.F.; Zagardo, M.T.

    1999-01-01

    Purpose: MR imaging and cerebral angiography were correlated in patients with primary angiitis of the central nervous system (PACNS) to assess the relative roles of these imaging modalities in the diagnosis. Material and Methods: In 9 patients, MR imaging and angiography were compared with regard to the relative involvement of each major vascular territory. Vascular territories assessed were the anterior, middle, and posterior cerebral arteries, and the posterior fossa. Results: All patients had angiographic findings consistent with vasculitis in multiple vascular territories. MR findings ranged from normal to diffusely abnormal. One patient had a completely normal MR investigation. Of 50 territories affected by vasculitis on angiography, 17 (34%) were normal on MR. Conclusion: Relative to cerebral angiography, MR imaging is a poor indicator of the presence or absence of PACNS. Angiography is indicated when clinical suspicion of PACNS is strong, regardless of the findings on MR. (orig.)

  5. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  6. Magnetic resonance angiography in suspected cerebral vasculitis

    International Nuclear Information System (INIS)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido; Maes, Frederik; Velghe, Beatrijs

    2004-01-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  7. Magnetic resonance angiography of the cerebral vessels

    International Nuclear Information System (INIS)

    Peters, P.E.; Bongartz, G.; Drews, C.

    1990-01-01

    In a prospective study involving 52 patients, magnetic resonance angiography (MRA) was compared with arterial digital subtraction angiography (IA-DSA). MRA was performed within three days of the IA-DSA. It was carried out without knowledge of the findings on IA-DSA. Of 38 stenoses of the carotid arteries or their branches, demonstrated by IA-DSA, 33 could be seen on MRA; in four cases the stenosis was outside the imaging area of the coil. Sixteen out of 17 carotid occlusions were diagnosed by MRA. There was one false positive. In the vertebral artery territory, eleven out of 13 stenoses and three out of four occlusions were diagnosed by MRA. In evaluating the degree of stenosis, there was agreement in only 16 out of 33 cases. MRA over-estimated the severity of stenoses in 15 cases and underestimated it in two. MRA is a new non-invasive method in the diagnosis of cerebro-vascular disease which must be evaluated by further studies. (orig.) [de

  8. Magnetic resonance angiography in suspected cerebral vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido [Department of Radiology, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Maes, Frederik [Department of Medical Imaging Computing, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Velghe, Beatrijs [Department of Radiology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600, Genk (Belgium)

    2004-06-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  9. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth

  10. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  11. Labelling of histone H5 and its interaction with DNA. 1. Histone H5 labelling with fluorescein isothiocyanate.

    Science.gov (United States)

    Favazza, M; Lerho, M; Houssier, C

    1990-06-01

    Histone H5 has been labelled with fluorescein isothiocyanate (FITC) with particular attention to the reaction conditions (pH, reaction time and input FITC/H5 molar ratio) and to the complete elimination of non-covalently bound dye. We preferred to use reaction conditions which yielded non-specific uniform labelling rather than specific alpha-NH2 terminal labelling, in order to obtain higher sensitivity in further studies dealing with the detection of perturbation at the binding sites of H5 on DNA. FITC-labelled H5 was further characterized by absorption and circular dichroism spectroscopy, and the fluorescein probe titrated in the 4-8 pH range. The structural integrity of H5 was found to be preserved after labelling. The positive electrostatic potential of the environment in which the FITC probe is embedded in the arginine/lysine-rich tails of H5 is believed to be responsible for the drop of pK of 1 unit found for H5-FITC as compared to free FITC. For the globular part of H5, the pK of covalently-bound FITC was only slightly lowered; this is a consequence of the much lower content in positively-charged amino-acid side chains in this region.

  12. Quantitative evaluation of experimental choroidal neovascularization by confocal scanning laser ophthalmoscopy: fluorescein angiogram parallels heparan sulfate proteoglycan expression

    Directory of Open Access Journals (Sweden)

    C.V. Regatieri

    2010-07-01

    Full Text Available The objective of the present study was to develop a quantitative method to evaluate laser-induced choroidal neovascularization (CNV in a rat model using Heidelberg Retina Angiograph 2 (HRA2 imaging. The expression of two heparan sulfate proteoglycans (HSPG related to inflammation and angiogenesis was also investigated. CNV lesions were induced with argon laser in 21 heterozygous Zucker rats and after three weeks a fluorescein angiogram and autofluorescence exams were performed using HRA2. The area and greatest linear dimension were measured by two observers not aware of the protocol. Bland-Altman plots showed agreement between the observers, suggesting that the technique was reproducible. After fluorescein angiogram, HSPG (perlecan and syndecan-4 were analyzed by real-time RT-PCR and immunohistochemistry. There was a significant increase in the expression of perlecan and syndecan-4 (P < 0.0001 in retinas bearing CNV lesions compared to control retinas. The expression of these two HSPG increased with increasing CNV area. Immunohistochemistry demonstrated that the rat retina damaged with laser shots presented increased expression of perlecan and syndecan-4. Moreover, we observed that the overexpression occurred in the outer layer of the retina, which is related to choroidal damage. It was possible to develop a standardized quantitative method to evaluate CNV in a rat model using HRA2. In addition, we presented data indicating that the expression of HSPG parallels the area of CNV lesion. The understanding of these events offers opportunities for studies of new therapeutic interventions targeting these HSPG.

  13. Permeability of blood-tear barrier to fluorescein and albumin after application of platelet-activating factor to the eye of the guinea pig

    Directory of Open Access Journals (Sweden)

    J. L. Van Delft

    1997-01-01

    Full Text Available One of the inflammatory responses of the eye to local application of platelet-activating factor (PAF is oedema of the conjunctiva, caused by extravasation of plasma. Aim of the study was to investigate if fluorescein would leak from the blood into the tears together with plasma protein after application of PAF to the eye. Fluorescein was given intraperitoneally 30 min prior to application of 25 μl of 0.1% solution of PAF. Thirty min after PAF the tear film was collected by washing the surface of the eye with 25 μl of phosphate buffered saline (PBS. Fluorescein in eye washings and in plasma was measured by fluorophotometry and albumin by immunodiffusion. Both fluorescein and albumin appeared in a related fashion in tears, being absent in washings of placebo-treated control eyes. Extravasation of fluorescein can be used as a measure for plasma leakage in the conjunctiva with the advantage over the Evans Blue method that the former is a non-invasive method.

  14. Gadolinium-enhanced MR angiography of arterial occlusive disease in lower extremity : comparison with conventional digital subtraction angiography

    International Nuclear Information System (INIS)

    Shin, Sang June; Koh, Young Hwan; Cha, Joo Hee; Kim, Hyu Beom; Chung, Jin Wook; Park, Jae Hyung

    2000-01-01

    To compare the diagnostic value of gadolinium-enhanced MR angiography with that of conventional digital subtraction angiography for the evaluation of lower extremity arterial occlusive diseases. In 26 patients with symptomatic lower extremity arterial occlusive disease, both conventional digital subtraction angiography (DSA) and gadolinium-enhanced MR angiography (CE-MRA) were performed during the same week. MR angiography was performed using three-dimensional gradient-echo acquisition before, and two sequential acquisitions after, the administration of gadolinium (0.2 mmol/kg). In 23 patients, two separate, contiguous areas were scanned using additional doses. In three patients, only one field with a suspicious lesion was scanned. Three radiologists independently analyzed the CE-MRA and DSA findings of each vascular segment (20 segments per arterial tree) for the presence of obstructive lesions; the grade assigned was either mild or none (less than 50%), stenotic (50%-99%), or occlusion (100%). From among a total of 462 segments, DSA detected 99 which were significantly narrowed (stenosis, 33; occlusion, 66). Using MR angiography, 102 segments (stenosis 39; occlusion, 63) were identified, and 94 lesions (stenosis, 32; occlusion, 62) were graded correctly. Seven lesions were overestimated and four were underestimated. For the detection of hemodynamically significant stenosis or occlusions using MR angiography, sensitivity, specificity, and diagnostic accuracy were 95%, 98%, and 98% (G=3D0.995, P less than 0.001), respectively. To prove the absence of lesions, we repeated DSA in two patients with arterial spasm due to puncture. Three occluded segments seen on DSA, which revealed intact segments on MR angiography, suggested slow distal flow after reconstitution. For the evaluation of lower extremity arterial occlusive disease, the diagnostic value of gadolinium-enhanced MR angiography is comparable with that of digital subtraction angiography. The advantages of the

  15. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    International Nuclear Information System (INIS)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient

  16. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient.

  17. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  18. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  19. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  20. Comparison of magnetic resonance angiography and conventional angiography in sickle cell disease: clinical significance and realibility

    International Nuclear Information System (INIS)

    Kandeel, A.Y.; Zimmerman, R.A.; Ohene-Frempong, K.

    1996-01-01

    We retrospectively reviewed the medical records and conventional angiograms of 21 patients with known sickle cell disease, who underwent a total of 50 magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) studies. MRA and conventional angiography were assessed separately for evidence of stenosis or occulusion. Follow up MRI/MRA studies were also assessed for evidence of progression, regression or stability of the disease in these patients. In the carotid circulation, MRA made the correct diagnosis in 85% of the vessels evaluated with a sensitivity of 80.5% and a specificity of 94%. MRA was also found to show evidence of disease progression, more often than did MRI or the clinical condition of the patients. (orig.)

  1. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  2. An investigation of cerebral magnetic resonance angiography, 4

    International Nuclear Information System (INIS)

    Takeda, Sadanori; Sadamoto, Kazuhiko; Ohue, Shiro; Todo, Hirooki; Sakaki, Saburo.

    1991-01-01

    We have been studying MR angiography using the 0.5 tesla system. Recently we developed three-dimensional MR angiography on the 0.5 tesla system using the gradient-echo technique. The purpose of this study is to evaluate the clinical ability of this newly developed 3-D MR angiography to detect intracranial vascular diseases in comparison with SE or 2-D MR angiography. Twenty-eight patients (15 cerebral aneurysms, 8 arteriovenous malformations, and 5 others) were examined. Three-dimensional MR angiography was performed with TRs of from 60 to 90 msec, TEs of from 16 to 22 msec, flip angls of from 15 to 45 degrees, and a 256x256x16 or 32 matrix. The imaging volumes ranged in thickness from 48 to 64 mm. In our study, a subtraction technique composed of rephased and dephased sequences was applied. As the result of utilizing 0.5 tesla 3-D MR angiography with optimal parameters, good visualization of main cerebral arteries such as second-order branches was obtained. Cerebral aneurysms, AVMs, and arterial occlusions were also well demonstrated, but some of the giant aneurysms were displayed insufficiently for the various flows to be determined. We concluded that 3-D MR angiography on the 0.5 tesla system has the ability to detect intracranial vascular lesions and should be the method for the screening and follow-up of intracranial vascular diseases. (author)

  3. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  4. E-learn Computed Tomographic Angiography

    DEFF Research Database (Denmark)

    Havsteen, Inger; Christensen, Anders; Nielsen, Jens K

    2012-01-01

    BACKGROUND: Computed tomographic angiography (CTA) is widely available in emergency rooms to assess acute stroke patients. To standardize readings and educate new readers, we developed a 3-step e-learning tool based on the test-teach-retest methodology in 2 acute stroke scenarios: vascular...... occlusion and "spot sign" in acute intracerebral hemorrhage. We hypothesized that an e-learning program enhances reading skills in physicians of varying experience. METHODS: We developed an HTML-based program with a teaching segment and 2 matching test segments. Tests were taken before and after...... sign correctly 69% before versus 92% after teaching (P = .009) and reported a median self-perceived diagnostic certainty of 50% versus 75% (P = .030). Self-perceived diagnostic certainty revealed no significant increase for vascular occlusion. CONCLUSIONS: The e-learning program is a useful educational...

  5. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  6. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  7. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1990-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. (orig./HSI)

  8. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  9. Transbrachial artery approach for selective cerebral angiography

    International Nuclear Information System (INIS)

    Touho, Hajime; Karasawa, Jun; Shishido, Hisashi; Morisako, Toshitaka; Numazawa, Shinichi; Yamada, Keisuke; Nagai, Shigeki; Shibamoto, Kenji

    1990-01-01

    Transaxillary or transbrachial approaches to the cerebral vessels have been reported, but selective angiography of all four vessels has not been possible through one route. In this report, a new technique for selective cerebral angiography with transbrachial approach is described. One hundred and twenty three patients with cerebral infarction, vertebrobasilar insufficiency, intracerebral hemorrhage, epilepsy, or cerebral tumor were examined. Those patients consisted of 85 outpatients and 38 inpatients whose age ranged from 15 years old to 82 years old. The patients were examined via the transbrachial approach (97 cases via the right brachial, 29 cases via the left). Materials included a DSA system (Digital Fluorikon 5000, General Electric Co.), a 4 French tight J-curved Simmons 80-cm catheter, a 19-gauge extra-thin-wall Seldinger needle, and a J/Straight floppy 125-cm guide-wire. Generally, the volume of the contrast agent (300 mgI/ml iopamidol) used in the common carotid artery angiogram was 6 ml, while that used in the vertebral artery angiogram was 4 ml. If catheterization of the vertebral artery or right common carotid artery was unsuccessful, about 8 ml of the contrast agent was injected into the subclavian or branchiocephalic artery. Definitive diagnosis and a decision on proper treatment of the patients can be easily obtained, and the results were clinically satisfactory. Moreover, no complications were encountered in this study. This new technique making a transbrachial approach to the cerebral vessels using the DSA system is introduced here. Neurosurgeons can use this technique easily, and they will find that it provides them with all the information they need about the patient. (author)

  10. MR angiography of the iliofemoral artery system

    International Nuclear Information System (INIS)

    Steffens, J.C.; Link, J.; Brinkmann, G.; Reuter, M.; Heller, M.

    1997-01-01

    During the last years, magnetic resonance angiography (MRA) has become a widely used modality for intracerebral and carotid artery imaging. Due to technical limitations, the clinical impact of MRA in the iliofemoral arteries has been rather poor. New developments in MRA like ECG-triggered sequences and the occurrence of contrast-enhanced MRA has overcome most of these limitations. Therefore, a major advance in clinical use of these diagnostic tools can be predicted. This paper discussed the advantages of ECG-gated 2D-Phase contrast, ECG-gated 2D-Time-of-Flight and contrast enhanced FLASH 3D angiography sequences from a clinical point of view. 2D-PC-MRA is a robust technique, which provides an overview of the iliofemoral artery system in less than 5 minutes. Limitations are the true 2D impression of the sequence and the partial venous overlay. 2D-TOF-MRA on the other hand is time consuming, however it enables 3D reconstruction and effective venous suppression can be applied. Contrast enhanced MRA as the third sequence discussed provides high resolution images in less than 30 sec. However contrast bolus timing might be a problem. In conclusion the authors suggest a combination of 2D-PC-MRA and additional 2D-TOF sequences at questionable vacular areas as the modality of choice, due to the fact, that MRA of the iliofemoral arteries is mostly only one step of a complete lower limb examination. Contrast MRA might become the method of choice in the future however problems with multiple contrast injections and upper limits of contrast dose have to be solved. (orig.) [de

  11. Diagnostic problems in chest injuries (angiography)

    International Nuclear Information System (INIS)

    Wenz, W.; Strecker, E.P.; Kloehn, I.

    1979-01-01

    Roentgenography is the simplest and most reliable means to arrive at the diagnosis of chest injury. General roentgenograms are difficult to interpret as they tend to be technically imperfect. Fractures, emphysema, pneumothorax, accumulation of fluid can usually be ascertained directly; but the traumatic origin of changes in the pulmonary parenchyma or of an enlarged heart shadow cannot be reliably deduced from the X-ray appearance. It may provide some differential-diagnostic information but the correct interpretation of the findings depends on further observation. In 6-7% of severe chest trauma with vascular injuries and rupture of the diaphragm angiography is indicated. The evidence to be obtained from chest radiography should not be overestimated: fractures of ribs are sometimes overlocked, even by the expert; parenchymatous lesions may manifest themselves as shadows but their nature remains obscure until they have been related to the clinical and subsequent radiological findings. The same applies to rupture of the diaphragm, bronchi or vessels, if only the immediate posttraumatic roentgenographs are examined. A tent-shaped heart shadow is considered characteristic of the presence of fluid in the pericardium; this is valid only for chronic hydropericardium, but not for the potentially fatal cardiac tamponade; if the pericardium has lost its elasticity a haemorrhage of not more than 150 ml may prove fatal. Nor does the roentgenogram provide information about pulmonary function. Especially in cases of pulmonary shock minor changes in the chest roentgenogram may give a false sense of security when, in fact, blood gas analyses show that a life-endangering situation has developed. The radiologist who is aware of the limitations of the method will derive maximum diagnostic benefit from a chest angiography. No other method is capable of supplying information of such great importance in such a short time. (orig.) [de

  12. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  14. Raman spectroscopy in comparative investigations of mechanisms of binding of three molecular probes - fluorescein, eosin, and erythrosin - to human serum albumin

    Science.gov (United States)

    Vlasova, I. M.; Saletsky, A. M.

    2008-11-01

    The comparative analysis of binding of three molecular fluorescent probes (fluorescein, eosin, and erythrosin), belonging to one homologous family, to human serum albumin (HSA) is made by Raman spectroscopy method. The binding of all three probes to binding Center I of HSA is registered. The character of binding of initial probe of the given homologous family - fluorescein - to protein differs from character of binding of its halogen-derivatives (eosin and erythrosin) to protein. The differences in binding of these three probes to HSA are determined by value of electronegativity of atoms of lateral radicals in structural formulas of probes and, therefore, by value of pK of their ionized groups.

  15. Novel Fluorometric Method for the Determination of Production Rate and Steady-State Concentration of Photochemically Generated Superoxide Radical in Seawater Using 3',6'-(Diphenylphosphinyl)fluorescein.

    Science.gov (United States)

    Anifowose, Adebanjo Jacob; Takeda, Kazuhiko; Sakugawa, Hiroshi

    2015-12-15

    Superoxide radical (O2(•-)) is an important reactive oxygen species in seawater. Measurements of its production rates and steady-state concentrations generated by photochemical processes have been a Herculean task over the years. In this study, a probe - 3'6'-(diphenylphosphinyl)fluorescein (PF-1) - was used to trap photochemically generated O2(•-) in seawater, thereby yielding fluorescein. The fluorescein produced was measured by an isocratic fluorescence HPLC at excitation/emission wavelengths of 490/513 nm, respectively. The reaction rate constant of PF-1 with O2(•-) (kPF-1) was pH-dependent: (3.2-23.5) × 10(7) M(-1) s(-1) at pHTOT 7.65-8.50. By applying appropriate equations, both the production rate and the steady-state concentration of O2(•-) generated by photochemical reactions in the seawater were quantified. Under the optimized experimental conditions, fluorescein standards (3-50 nM) exhibited linearity in the seawater by HPLC. The photoformation of fluorescein, due to the reaction of PF-1 with the O2(•-) photochemically produced in the seawater, was linear within the 20 min irradiation. The detection limit of the fluorescein photoformation rate was 0.03 pM s(-1), defined as 3σ of the lowest standard fluorescein concentration per 20 min irradiation. Using this value, the yield of fluorescein, and the fraction of O2(•-) that reacted with PF-1 in the seawater, the detection limit of the O2(•-) photoformation rate was 1.78 pM s(-1). Superoxide measurements using the proposed method were relatively unaffected by the potential interfering species in seawater. Application of the proposed method to ten (10) seawater samples from the Seto Inland Sea, Japan, resulted in measured O2(•-) photoformation rates of 3.1-8.5 nM s(-1), with steady-state concentrations ranging (0.06-0.3) × 10(-10) M. The method is simple, requires no technical sample preparation, and can be used to analyze a large number of samples.

  16. Evaluation of the pedal artery: comparison of three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kang, Sung Gwon; Byun, Joo Nam; Kim, Young Cheol; Choi, Jeong Yeol; Kim, Dong Hyun [College of Medicine, Chosun Univ., Kwangju (Korea, Republic of)

    2002-07-01

    To compare the three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography (DSA) for evaluation of the pedal artery. In 12 extremities of 11 patients, both digital subtraction angiography (DSA) and contrast-enhanced MR angiography (CE-MR angiography) were performed during the same week. Among ten of the 11 patients, the following conditions were present: atherosclerosis (n=4), diabetic foot (n=3), Buerger's disease (n=1), calciphylactic arteriopathy (n=1) and arteriovenous malformation of the foot (n=1). The remaining patient underwent angiography prior to flap surgery. For MR angiography, a 1.5T system using an extremity or head coil was used. A three-dimensional FISP (fast imaging with steady state precession) sequence was obtained before enhancement, followed by four sequential acquisitions (scan time, 20 secs, scan interval time, 10 secs) 10 seconds after intravenous bolus injection of normal saline (total 10 cc), following intravenous administration of gadolinium (0.02 mmol/kg, 3 ml/sec). Arterial segments of the ankle and foot were classified as the anterior or posterior tibial artery, the distal peroneal artery, the medial or lateral plantar artery, the pedal arch, and the dorsalis pedis artery. Two radiologists independently analysed visualization of each arteraial segment and the mean of visible arterial segments in one extreminty using CE-MR angiography and DSA. Among 84 arterial segments, 16 were invisible at both CE-MR angiography and DSA, while 39 were demonstrated by both modalities. Twenty-six segments were visible only at CE-MR angiography and three only at DSA. CE-MR angiography displayed a higher number of arterial segments than DSA (mean, 5.42 vs. mean 3.50, respectively), a difference which was statistically significant (p<0.000). The difference between each arterial segment was not statistically significant, except for the dorsalis pedis artery (t test, p<0.000). In that it provides additional information for

  17. Rationalization of the Color Properties of Fluorescein in the Solid State: A Combined Computational and Experimental Study.

    Science.gov (United States)

    Arhangelskis, Mihails; Eddleston, Mark D; Reid, David G; Day, Graeme M; Bučar, Dejan-Krešimir; Morris, Andrew J; Jones, William

    2016-07-11

    Fluorescein is known to exist in three tautomeric forms defined as quinoid, zwitterionic, and lactoid. In the solid state, the quinoid and zwitterionic forms give rise to red and yellow materials, respectively. The lactoid form has not been crystallized pure, although its cocrystal and solvate forms exhibit colors ranging from yellow to green. An explanation for the observed colors of the crystals is found using a combination of UV/Vis spectroscopy and plane-wave DFT calculations. The role of cocrystal coformers in modifying crystal color is also established. Several new crystal structures are determined using a combination of X-ray and electron diffraction, solid-state NMR spectroscopy, and crystal structure prediction (CSP). The protocol presented herein may be used to predict color properties of materials prior to their synthesis. © 2016 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  18. Fluorescein isothiocyanate and rhodamine B dye encapsulated mesoporous SiO2 for applications of blue LED excited white LED

    Science.gov (United States)

    Das, Sourav; Manam, J.

    2018-05-01

    In this work, the fluorescein isothiocyanate (FITC) and rhodamine B (RhB) dyes were encapsulated in mesoporous silica nanoparticles (MSNp). The MSNp-FITC-RhB nanohybrids phosphor showed a dichromatic PL emission at green region and orange region when excited at 460 nm. A Forster Resonance Energy Transfer (FRET) was observed from FITC to RhB. The materials were further characterized by XRD, FTIR, TEM, and temperature dependent photoluminescence. The CIE coordinates were tuned from greenish yellow to the orange region and quantum yield was reached 52.04% based on FRET. So by combining the MSNp-FITC-RhB nanohybrids phosphor with the blue LED chip, the white light emission with flexible Color Correlated Temperature and improved Color Rendering Index can be obtained.

  19. Biochar amendment to lead-contaminated soil: Effects on fluorescein diacetate hydrolytic activity and phytotoxicity to rice.

    Science.gov (United States)

    Tan, Xiaofei; Liu, Yunguo; Gu, Yanling; Zeng, Guangming; Hu, Xinjiang; Wang, Xin; Hu, Xi; Guo, Yiming; Zeng, Xiaoxia; Sun, Zhichao

    2015-09-01

    The amendment effects of biochar on total microbial activity was measured by fluorescein diacetate (FDA) hydrolytic activity, and phytotoxicity in Pb(II)-contaminated soils was examined by the application of 4 different biochars to soil, with rice as a test plant. The FDA hydrolytic activities of biochar-amended soils were much higher than that of the control. The survival rate of rice in lead-contaminated biochar-amended soils showed significant improvement over the control, especially for bamboo biochar-amended soil (93.3%). In addition, rice grown in lead-contaminated control sediment displayed lower biomass production than that in biochar-amended soil. The immobilization of Pb(II) and the positive effects of biochar amendment on soil microorganisms may account for these effects. The results suggest that biochar may have an excellent ability to mitigate the toxic effects of Pb(II) on soil microorganisms and rice. © 2015 SETAC.

  20. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  1. MR and angiography: Evaluation of the hemodynamics of portal hypertension

    International Nuclear Information System (INIS)

    Torres, W.E.; Gaylord, G.M.; Whitmire, L.; Chuang, V.P.; Bernardino, M.E.

    1986-01-01

    Forty-two MR imaging examinations and angiographic procedures in 38 patients with portal hypertension were compared for how well the images depicted portal perfusion and direction of flow, portal vein thrombosis, and the presence and type of shunt. Thirty-three MR imaging studies indicated grade I or II portal flow. In 29 cases portal flow was grade I or II by angiography; in the remaining cases the flow was grade IV. In a total of eight cases portal flow was grade IV by angiography, but none appeared to be grade IV on MR imaging. Both MR imaging and angiography detected portal vein thrombosis (41 of 42 cases). MR imaging and angiography agreed as to whether a shunt was present or absent, and patent or occluded (41 of 42 cases). Currently, MR imaging is an unsatisfactory modality by which to grade portal flow. MR imaging does depict portal vein thrombosis well, and can be used to determine patency of surgical shunts

  2. Digital angiography and surgery in the same room

    International Nuclear Information System (INIS)

    Goldman, M.L.; Hack, S.N.; Sarrafizadeh, M.S.; Marar, H.G.; Behar, D.J.; Chigurupati, R.C.; Klein, S.I.; Widlus, D.M.; Fortune, J.B.

    1986-01-01

    Albany Medical Center and private industries (XRE and United X-ray corporations) have collaborated to develop a room within the operating suite that allows high-speed and high-resolution digital angiography and surgery to be performed simultaneously. Patients who have sustained massive trauma can be transferred directly from the ambulance to this new facility. While the patient is undergoing exploratory laparotomy, other vital areas of the body can be evaluated by angiography. This combined approach of surgery and angiography has also led to improved management of patients with massive or occult intestinal hemorrhage and patients with peripheral vascular disease. Other patients undergoing difficult emergency or elective surgery, as in the biliary tract, can now have available the benefits of an operating room facility that also allows high-resolution fluoroscopy and complete angiography to be undertaken

  3. Audit of radiation dose to patients during coronary angiography

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Chandy, Sunil; Peace, Timothy B.S.; George, Paul V.; John, Bobby; Pati, Purendra

    2007-01-01

    There is a widespread concern about radiation doses imparted to patients during cardiology procedures in the medical community. The current study intends to audit and optimize radiation dose to patients undergoing coronary angiography performed using two dedicated cardiovascular machines

  4. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  5. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  6. Superselective pseudo-continuous arterial spin labeling angiography

    International Nuclear Information System (INIS)

    Jensen-Kondering, Ulf; Lindner, Thomas; Osch, Matthias J.P. van; Rohr, Axel; Jansen, Olav; Helle, Michael

    2015-01-01

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  7. Renal computed angiography. Part I: Renal CT arteriography in hypertension

    International Nuclear Information System (INIS)

    Al-Amin, M.; Hadjidekov, V.

    2012-01-01

    Visualization of renal vasculature is needed in several clinical condition among which hypertension is dominant. CT angiography now day replaces catheter angiography as non-invasive method. The goal of this study is to present initial authors experience in visualization of renal arteries using 64 MDCT and to evaluated the utility in hypertensive patients. MDCT assures excellent assessment of renal arteries conditions. Multiplanar reconstruction and allow better delineation in tortuous vessels course and anatomic variants. (authors)

  8. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  9. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  10. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  11. Value of MR-angiography in brain infarction

    International Nuclear Information System (INIS)

    Pirronello, Veronica; Capizzano, Aristides A.; Chouela, Carolina L.; Ternak, Alejandro; Ramirez, Susana; Mazzuco, Juan C.

    2004-01-01

    A retrospective study has been performed in a series of 237 patients, with brain and neck MR and MR angiography techniques. 108/237 (45.5%) patients presented either hemorrhage or lacunar and non lacunar ischemic stroke, 67 of which showed restricted diffusion. Diffusion and perfusion techniques can significantly contribute to study acute stroke. In our series MR angiography showed a 4% sensitivity to detect small arteries pathology. (author)

  12. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  13. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  14. Clinical experience of magnetic resonance angiography in hand surgery

    International Nuclear Information System (INIS)

    Kawabata, Hidehiko; Yasui, Natsuo; Kitano, Motohiro; Sai, Eikoh

    1996-01-01

    Magnetic resonance angiography was performed in fourteen patients with congenital hand abnormalities. A two-dimentional time-of-flight imaging clearly demonstrated presence or absence of the radial, ulnar, and anterior interosseous arteires at forearm. However, smaller arteries such as digital arteries were depressed sometimes. This fact makes clinical application of the method somewhat limited. At present. appropriate applications in orthopaedic fields are evaluation of run-off of the major vessels after trauma or atherosclerotic diseases, venous vascular problems such as thrombophlebitis and aneurysm, and preoperative and post operative evaluation in microsurgery. If more detailed information is required, for example, in differential diagnosis of tumors conventional angiography or digital subtraction angiography is recommended. Because magnetic resonance angiography is non-invasive and does not need anesthesia, it is suitable especially for children. No requirement of contrast medium makes it easy to apply angiography to high risk patients and allergic patients to iodine. Technical advancement in near future will rise up magnetic resonance angiography to a standard evaluation method for vascular problems in orthopaedic fields very soon. (author)

  15. CT Angiography in the Diagnosis of Brain Death

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Bohatyrewicz, Romuald; Walecka, Anna; Sołek-Pastuszka, Joanna; Rowiński, Olgierd; Walecki, Jerzy

    2014-01-01

    Summary Brain death is defined as the irreversible cessation of functioning of the entire brain, including the brainstem. Brain death is principally established using clinical criteria including coma, absence of brainstem reflexes and loss of central drive to breathe assessed with apnea test. In situations in which clinical testing cannot be performed or when uncertainty exists about the reliability of its parts due to confounding conditions ancillary tests (i.a. imaging studies) may be useful. The objective of ancillary tests in the diagnosis of brain death is to demonstrate the absence of cerebral electrical activity (EEG and evoked potentials) or cerebral circulatory arrest. In clinical practice catheter cerebral angiography, perfusion scintigraphy, transcranial Doppler sonography, CT angiography and MR angiography are used. Other methods, like perfusion CT, xenon CT, MR spectroscopy, diffusion weighted MRI and functional MRI are being studied as potentially useful in the diagnosis of brain death. CT angiography has recently attracted attention as a promising alternative to catheter angiography – a reference test in the diagnosis of brain death. Since 1998 several major studies were published and national guidelines were introduced in several countries (e.g. in France, Austria, Switzerland, the Netherlands and Canada). This paper reviews technique, characteristic findings and criteria for the diagnosis of cerebral circulatory arrest in CT angiography

  16. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  17. In situ measurement of the efficiency of filtration installations in the nuclear industry by the soda-fluorescein (uranin) aerosol method: AFNOR standard NFX 44.011

    International Nuclear Information System (INIS)

    Dupoux, J.

    1981-01-01

    The in situ measurement of the efficiency of filtering installations in the French nuclear industry using the soda-fluorescein (uraniun) aerosol method is presented. A brief description and the interest of the method are discussed. Its use for the location of defects in filter elements and for in situ control of casing with tandem HEPA filter stages is described

  18. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  19. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    International Nuclear Information System (INIS)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin; Ozdemir, Ozcan; Kurt, Aydin; Sakarya, Mehmet Emin; Tas, Ismet

    2007-01-01

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels

  20. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  1. Intravenous coronary angiography using the orbital radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuka, Sadanori; Yamaguchi, Iwao; Wu, Jin; Takeda, Toru; Itai, Yuji; Maruhashi, Akira [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Hyodo, Kazuyuki; Ando, Masami [High Energy Accelerator Research Org., Tsukuba, Ibaraki (Japan). Inst. of Materials Structure Science

    2002-09-01

    This review described the progress and current status of intravenous coronary angiography (IVCAG) using the orbital radiation generated by the synchrotron. Authors diagnosed 4 patients of coronary artery disease in 1996 and 33 until 2000. Monochromatic 2-D X-ray beam (2.0 X 10{sup 10} photons/mm{sup 2}/sec, 130 X 75 mm) of 37 keV was obtained by non-symmetrical reflection of synchrotron radiation generated by 5.0 GeV accelerated electron. The use of 2-D beam enabled to give the dynamic IVCAG image in contrast with the static image by the 1-D slit beam. Intermittent irradiation (5 msec/100 msec) reduced the exposure dose to <750 mSv. Images were recorded in the Sony digital video-recorder placed behind the Sony Charge-coupled device (CCD) camera and Toshiba photo-multiplier, and gave the precision of 1 mm of the artery. The IVCAG by synchrotron radiation reduced patients' burden and was expected to be more widely used in future. (K.H.)

  2. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  3. Quantitative fluorescence angiography for neurosurgical interventions.

    Science.gov (United States)

    Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute

    2013-06-01

    Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.

  4. Cardiac complications of intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Neergaard, K.; Dirksen, K.L.; Andersen, I.; Galloee, A.M.; Madsen, E.B.

    1989-01-01

    In a prospective study of 103 patients the incidence of cardiac events during intravenous digital subtraction angiography (i.v. DSA) was investigated. Of 103 patients 17 had known ischaemic heart disease. The examination was performed with an ionic contrast medium, Urografin 76% (sodium megluminediatrizoate), administered by bolus injection into the right atrium. Patients with severe cardiac disease were examined only if the procedure was considered of vital importance. Cardiac events were defined as ST-segment changes of more than 0.1 mV, changes in heart rate of more than 20%, arrhythmias and such symptoms as chest pain and dyspnoea. Ischaemic ST-segment changes during i.v. DSA were observed in approximately 20% of the patients and were not related to the presence of known ischaemic heart disease. Three patients developed angina during the procedure. Among 12 patients with known angina only one patient developed angina during the procedure. In this study chest pain was infrequent (3%), but there was a relative high frequency of ECG changes (20%) not related to patients with ischaemic heart disease only. It is concluded that there is a risk of cardiac events during i.v. DSA, but the risk is not increased in patients with known ischaemic heart disease (if they do not suffer from congestive heart failure) as compared with other patients without known ischaemic heart disease. (orig.)

  5. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  6. Posterior encephalopathy with vasospasm: MRI and angiography

    International Nuclear Information System (INIS)

    Weidauer, S.; Gaa, J.; Lanfermann, H.; Zanella, F.E.; Sitzer, M.; Hefner, R.

    2003-01-01

    Posterior encephalopathy is characterised by headache, impairment of consciousness, seizures and progressive visual loss. MRI shows bilateral, predominantly posterior, cortical and subcortical lesions with a distribution. Our aim was to analyse the MRI lesion pattern and angiographic findings because the pathophysiology of posterior encephalopathy is incompletely understood. We report three patients with clinical and imaging findings consistent with posterior encephalopathy who underwent serial MRI including diffusion-weighted imaging (DWI) and construction of apparent diffusion coefficient (ADC) maps, and four-vessel digital subtraction angiography (DSA). DWI revealed symmetrical subcortical and cortical parieto-occipital high signal. High and also low ADCs indicated probable vasogenic and cytotoxic oedema. On follow-up there was focal cortical laminar necrosis, while the white-matter lesions resolved almost completely, except in the arterial border zones. DSA revealed diffuse arterial narrowing, slightly more marked in the posterior circulation. These findings suggest that posterior encephalopathy may in some cases be due to diffuse, severe vasospasm affecting especially in the parieto-occipital grey matter, with its higher vulnerability to ischemia. Cerebral vasospasm due to digitoxin intoxication, resulting in posterior encephalopathy, has not yet been described previously. (orig.)

  7. Localization strategy for magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Cheng Liuquan; Gao Yuangui; Sun Wei; Sheng Fugeng; Cai Youquan

    2003-01-01

    Objective: To develop a localization strategy for magnetic resonance coronary angiography (MRCA). Methods: In 89 subjects, the standard 4-chamber view and long-axis view of left and right ventricle were acquired using Fast-Imaging-Employing-Steady-State-Acquisition (FIESTA) sequence in CINE mode, and the trigger-delay time for mid-diastolic phase was determined. Coronary vessels including right coronary artery (RCA), left main (LM), left anterior descending (LAD), and left circumflex (LCX) were localized and imaged using 3- dimensional fat-suppressed FIESTA sequence during end-expiration. The reproducibility of the localization strategy was evaluated by taking the standard of coronary segmentation system recommended by American Heart Association. Results: Eighty-six subjects completed the examination with full respiratory co-operation and the indication ratio was 96.63%. Nine planes were optimized as the standard to target the main branches of coronary arteries, and a comprehensive reproducibility reached 100% in demonstrating the proximal and middle segment of RCA (AHA-18, 19), LM (AHA-1, 2), proximal and middle segment of LAD (AHA-3, 5, 7), and proximal LCX (AHA-10). The reproducibility for the demonstration of distal segments of LAD, LCX, and RCA (AHA-9, 14, 21) was 94.19%, 72.09%, and 96.51%, respectively. Conclusion: This is a simple and practical localization strategy for MRCA. It could image the proximal and middle segments of the coronary arteries with good reproducibility, which indicates the potential for clinical application

  8. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Gouliamos, A.; Gotsis, E.; Vlahos, L.; Samara, C.; Kapsalaki, E.; Rologis, D.; Kapsalakis, Z.; Papavasiliou, C.

    1992-01-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  9. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A. (Dept. of Radiology, Athens Univ. (Greece)); Gotsis, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Vlahos, L. (Dept. of Radiology, Athens Univ. (Greece)); Samara, C. (Dept. of Radiology, Athens Univ. (Greece)); Kapsalaki, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Rologis, D. (Dept. of Neurosurgery, Athens General Hospital (Greece)); Kapsalakis, Z. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Papavasiliou, C. (Dept. of Radiology, Athens Univ. (Greece))

    1992-12-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  10. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  11. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  12. A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats.

    Directory of Open Access Journals (Sweden)

    Jonathan P Wigg

    Full Text Available In-vivo imaging of choroidal neovascularization (CNV has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser generated CNV by rupture of Bruch's membrane in rodents. Heretofore CNV evaluation via in-vivo imaging techniques has been hamstrung by a lack of appropriate rodent fundus camera and a non-standardised analysis method. The aim of this study was to establish a simple, quantifiable method of fluorescein fundus angiogram (FFA image analysis for CNV lesions.Laser was applied to 32 Brown Norway Rats; FFA images were taken using a rodent specific fundus camera (Micron III, Phoenix Laboratories over 3 weeks and compared to conventional ex-vivo CNV assessment. FFA images acquired with fluorescein administered by intraperitoneal injection and intravenous injection were compared and shown to greatly influence lesion properties. Utilising commonly used software packages, FFA images were assessed for CNV and chorioretinal burns lesion area by manually outlining the maximum border of each lesion and normalising against the optic nerve head. Net fluorescence above background and derived value of area corrected lesion intensity were calculated.CNV lesions of rats treated with anti-VEGF antibody were significantly smaller in normalised lesion area (p < 0.001 and fluorescent intensity (p < 0.001 than the PBS treated control two weeks post laser. The calculated area corrected lesion intensity was significantly smaller (p < 0.001 in anti-VEGF treated animals at 2 and 3 weeks post laser. The results obtained using FFA correlated with, and were confirmed by conventional lesion area measurements from isolectin stained choroidal flatmounts, where lesions of anti-VEGF treated rats were significantly smaller at 2 weeks (p = 0.049 and 3 weeks (p < 0.001 post laser.The presented method of in

  13. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  14. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  15. Transient Global Amnesia following Neural and Cardiac Angiography May Be Related to Ischemia

    Directory of Open Access Journals (Sweden)

    Hongzhou Duan

    2016-01-01

    Full Text Available Introduction. Transient global amnesia (TGA following angiography is rare, and the pathogenesis has not been illustrated clearly till now. The aim of this research is to explore the pathogenesis of TGA following angiography by analyzing our data and reviewing the literature. Methods. We retrospectively studied 20836 cases with angiography in our hospital between 2007 and 2015 and found 9 cases with TGA following angiography. The data of these 9 cases were analyzed. Results. We found all 9 cases with TGA following neural angiography (5 in 4360 or cardiac angiography (4 in 8817 and no case with TGA following peripheral angiography (0 in 7659. Statistical difference was found when comparing the neural and cardiac angiography group with peripheral group (p=0.022. Two cases with TGA were confirmed with small acute infarctions in hippocampus after angiography. This might be related to the microemboli which were rushed into vertebral artery following blood flow during neural angiography or cardiac angiography. There was no statistical difference when comparing the different approaches for angiography (p=0.82 and different contrast agents (p=0.619. Conclusion. Based on the positive findings of imaging study and our analysis, we speculate that ischemia in the medial temporal lobe with the involvement of the hippocampus might be an important reason of TGA following angiography.

  16. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  17. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  18. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  19. Uterine artery embolization angiography and fertility related aspects

    Directory of Open Access Journals (Sweden)

    Irina A. Horhoianu

    2016-05-01

    Full Text Available Purpose. Uterine artery embolization is a minimally invasive technique. It applies the principle of targeted anatomical structure devascularisation with utility in fibroid conservative therapy, including for future fertility preserving status. The objective of our paper represents a description and evaluation of angiography utility as a predictive method for fertility maintenance. Material and Methods. The angiography and ultrasound aspects obtained from a prospective study in which selected patients have undergone uterine artery embolization for fertility preservation are detailed. Results. The following angiography aspects have been detected: left- right shunt and utero-ovarian collaterals; these have been compared with the ultrasound aspects related to the fibroid evolution form a volumetric and Doppler ultrasound point of view. The angiographical description predicts the impact on post embolization fibroid evolution and upon fertility. An analysis is made in order to assess the way in which angiography can contribute to fertility alteration. Conclusions. The angiography aspects during embolization and the following ultrasound aspects can represent predictive factors as to fertility evolution after uterine artery embolization.

  20. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  1. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  2. Medical radiation safety in the angiography room

    International Nuclear Information System (INIS)

    Kudou, Tamaki

    2011-01-01

    Author's efforts for angiographic procedure and technique aiming to reduce patient's exposure are described on a case with radiation skin hazard and on considerations of regulations and investigations. The case is a male patient (45 years old at the first intracardiac catheter examination, stature 164 cm, body wt. 116 kg), who, due to the diagnosis of angina pectoris and cardiac infarction, has the 5-year history of 5 coronary angiography (CAG), 6 percutaneous coronary intervention (PCI) and 1 off-pump coronary arterial bypass grafting (CABG). Because of serious skin injury and pain development after later PCI (172.2 min) (Oct. 2006) and their exacerbation after the latest PCI (27.1 min) (Apr. 2007), skin transplantation is conducted (Nov.). The exposure dose at the later PCI above is estimated to be around 12 Gy. Based on the case, consideration is made on regulatory recommendations by FDA, IAEA, ICRP, and investigational results of fluoroscopic mode vs dose by members of Japanese Circulatory Technology. With those references where the fluoroscopy at 20 mGy/min is assumed, the dose 12 Gy estimated above is thought to be resulted from the fluoroscopic dose >50 mGy/min within about 4 hr. To reduce the exposure, the author gives 11 items to be noted in interventional radiology: short fluoroscopic time, low rate pulse, minimal acquisition, use of additional filter, dose optimization, long distance between focus and skin, short distance between image intensifier (I.I.) and/or flat panel detector (FPD), minimal field, to avoid the excess inch-up, continuous maintenance of equipment, and record/preservation of the dose indicated by the machine. (T.T.)

  3. Fundus fluorescence Angiography in diagnosing diabetic retinopathy.

    Science.gov (United States)

    Wang, Shuhui; Zuo, Yuqin; Wang, Ning; Tong, Bin

    2017-01-01

    To investigate the manifestation characteristics of fundus fluorescence angiography (FFA) and its values in diagnosing diabetic retinopathy through comparing direct ophthalmoscopy. Two hundred fifty patients (500 eyes) who were suspected as diabetic retinopathy and admitted to the hospital between February 2015 and December 2016 were selected. They underwent direct ophthalmoscopy and FFA. The manifestation characteristics of FFA in the diagnosis of diabetic retinopathy were summarized. The two examination methods were compared. In the diagnosis with direct ophthalmoscopy, 375 eyes out of 500 eyes were diagnosed as diabetic retinopathy (75%); there were 74 eyes at stage I, 88 eyes at stage II, 92 eyes at stage III, 83 eyes of stage IV, 28 eyes of stage V and 10 eyes of stage VI. In the diagnosis with FFA, 465 eyes out of 500 eyes were diagnosed as diabetic retinopathy (93%); there were 94 eyes at stage I, 110 eyes at stage II, 112 at stage III, 92 eyes at stage IV, 41 eyes at stage V and 16 eyes at stage VI. The detection rate of diabetic retinopathy using FFA was significantly higher than that using direct ophthalmoscopy (Pretinopathy (67.96%), 75 eyes had pre-proliferative lesions (16.13%), 149 eyes had proliferative lesions (32.04%), 135 eyes had diabetic maculopathy (29.03%) and 31 eyes had diabetic optic disc lesions (6.67%). The detection rate of diabetic retinopathy using FFA is higher than that using direct ophthalmoscopy. FFA could accurately determine clinical stage. Therefore, it is an important approach in treatment efficacy evaluation and treatment guidance, suggesting a significant application value.

  4. Cerebral angiography in patients with complicated migraine

    Energy Technology Data Exchange (ETDEWEB)

    Zeiler, K.; Wessely, P.; Holzner, F.

    1985-08-01

    38 patients (mean age: 29 years) were investigated by means of complete 4-vessel angiography: all of them were suffering from complicated migraine without detectable vascular malformation. Stenoses of the great craniocervical vessels were found in 11 patients (28.9%), but there was not a single case of vascular occlusion. A correlation between the localization of the stenosis, the localization of the headache and the presumed region of the transient cerebral function disturbance was found only in a few patients. Concerning the morphological changes of the small intracranial arterial branches, there was hardly an difference between clinically affected and non-affected territories of the middle cerebral artery. The angiograms of the 38 cases of complicated migraine were compared with the angiograms of 40 patients suffering from strokes in the young and those of 49 patients with transient ischaemic attacks. There were remarkably fewer stenoses or occlusions in the great craniocervical arteries of patients suffering from complicated migraine (28.9%) than in the vessels of cases of stroke in the young (52.5%). However, the incidence was comparable with the results in patients with transient ischaemic attacks (34.7%). The degree of morphological changes in the small intracranial arterial branches is likely to depend primarily on the patient's age and less on the diagnosis. The results suggest that in almost 30% of patients with complicated migraine - even at juvenile age-stenoses of the great craniocervical vessels might be found. However, considering the fact that most of the stenoses are without haemodynamic significance and their localization is not in agreement with the clinical data, the pathogenetic value of these vessel wall changes is highly questionable. (Author).

  5. Methods to Evaluate the Effect of Ethanol on the Folate Analogue: Fluorescein Methotrexate Uptake in Human Proximal Tubular Cells

    Directory of Open Access Journals (Sweden)

    Sivakumar JT Gowder

    2009-01-01

    Full Text Available Ethanol-induced folate deficiency is due to effects of ethanol on folate metabolism and absorption. We have already shown by using different methods that ethanol interferes with reabsorption of folate from the proximal tubule. In this study, we have used the folate analogue, the fluorescein methotrexate (FL-MTX, in order to evaluate effects of ethanol on FL-MTX uptake by the human proximal tubular (HPT cells by using a confocal microscope and fluoroskan microplate reader. Since endothelins (ETs play a major role in a number of diseases and also in the damage induced by a variety of chemicals, we have used endothelin-B (ET-B and protein kinase-C (PKC inhibitors to evaluate the role of endothelin in ethanol-mediated FL-MTX uptake by using fluoroskan microplate reader. Confocal microscope and fluoroskan studies reveal that cellular absorption of FL-MTX is concentration-dependent. Moreover, ethanol concentration has an impact on FL-MTX uptake. Fluoroskan studies reveal that the ethanol-induced decrease in FL-MTX uptake is reversed by adding the ET-B receptor antagonist (RES-701-1 or PKC-selective inhibitor (BIM. Thus, we can conclude that ethanol may act via ET and ET in turn may act via ET-B receptor and the PKC signaling pathway to impair FL-MTX transport.

  6. In Vitro/In Vivo Evaluation of Radiolabeled [(99m)Tc(CO)3](+)-Hydroxyurea and Fluorescein Isothiocyanate-Hydroxyurea.

    Science.gov (United States)

    Yilmaz, Baris; Teksoz, Serap; Kilcar, Ayfer Yurt; Ucar, Eser; Ichedef, Cigdem; Medine, Emin Ilker; Ari, Kadir

    2016-02-01

    The aim of current study is to examine hydroxyurea (HU), which is an antineoplastic drug used for the treatment of leukemia, sickle-cell disease, HIV, psoriasis, thrombocythemia, and various neoplastic diseases in two aspects. The active ingredient hydroxyurea was obtained by purification of the capsule form drug, commercially named as HYDREA. Then, [(99m)Tc(CO)3](+)core radiolabeling with HU was performed as first aspect. Quality control studies of (99m)Tc(CO)3-HU complex were performed by thin-layer radiochromatography and high-performance liquid radiochromatography methods. The results demonstrated that the radiolabeling yield was quite high (98.43% ± 2.29%). Also, (99m)Tc(CO)3-HU complex has good stability during the 24-hour period. Biological behavior of (99m)Tc(CO)3-HU complex is evaluated by biodistribution studies on Wistar Albino rats. Fluorescein isothiocyanate (FITC) labeling of HU was performed as second aspect. Fluorometric evaluation of binding efficacy and fluorescence imaging studies on MCF7 and Hela cell lines were carried out. It was thought that the knowledge achieved in this study would contribute to using (99m)Tc(CO)3-HU complex as an imaging agent, which inhibits the DNA synthesis selectively, by inhibiting ribonucleotide reductase enzyme. It was observed that FITC-HU has noteworthy incorporation on both cell lines.

  7. Design of smart optical sensor using polyvinyl alcohol/Fluorescein sodium salt: Laser filters and optical limiting effect

    Science.gov (United States)

    Yahia, I. S.; Bouzidi, A.; Zahran, H. Y.; Jilani, W.; AlFaify, S.; Algarni, H.; Guermazi, H.

    2018-03-01

    Pure poly (vinyl alcohol) (PVA) and PVA doped Fluorescein-Sodium salt (FSS/PVA composite films) have synthesized on wide scale laser optical filters. The investigated polymeric composite films have been characterized using several methods. The XRD patterns exhibit a decrease of the average crystalline size and an increase of the internal strain, which explained the imperfection and distortion in the prepared films. The optical characterizations showed a decrease in the transmission of the incident light for different samples, which may be explained to the layer formed by intermolecular hydrogen bonding between the PVA matrix and the FSS particles. The FSS/PVA polymeric composite films are being a completely blocking in the UV-Vis light at the range between 190 and 560 nm, agreement with the optical limiting effect, which makes the composite films suitable for CUT-OFF laser filters applications. The decrease in its, directly and indirectly, allowed transition band gaps were controlled by the added FSS dyes molecules. The variation of the exponent frequency (s) of the power law for FSS/PVA polymeric composite films has been characterized to improve the hopping conduction mechanism in the materials. The dielectric permittivity (e‧) and dielectric loss (e'') have been decreased with increasing the applied frequency, and the incorporated FSS molecules due to the DC electric conductivity can cause the decreases of the polarization of the as-prepared films over the studied ranges.

  8. Transdermal delivery of fluorescein isothiocyanate-dextrans using the combination of microneedles and low-frequency sonophoresis

    Directory of Open Access Journals (Sweden)

    Boonnada Pamornpathomkul

    2015-10-01

    Full Text Available This study aimed to evaluate the patient-friendly methods that are used in the delivery of hydrophilic macromolecules into deep skin layers, in particular, the combination of microneedles patch (MNs patch and low-frequency sonophoresis (SN. The hydrophilic macromolecule drug fluorescein isothiocyanate (FITC-dextrans (FD-4: MW 4.4 kDa was used as the model drug in our experimental design. In this study, excised porcine skin was used to investigate and optimize the key parameters that determine effective MNs- and SN-facilitated FD-4 delivery. In vitro skin permeation experiments revealed that the combination of MNs patch with SN had a superior enhancing effect of skin permeation for FD-4 compared to MNs alone, SN alone or untreated skin, respectively. The optimal parameters for the combination of MNs and SN included the following: 10 N insertion force of MNs, 4 W/cm2 SN intensity, 6 mm radiation diameter of the SN probe, 2 min application time, and the continuous mode duty cycle of SN. In addition, vertical sections of skin, clearly observed under a confocal microscope, confirmed that the combination of MNs and SN enhanced permeation of FD-4 into the deep skin layers. These studies suggest that the combination of MNs and SN techniques could have great potential in the delivery of hydrophilic macromolecules into deep skin.

  9. Skull Base Meningiomas and Cranial Nerves Contrast Using Sodium Fluorescein: A New Application of an Old Tool.

    Science.gov (United States)

    da Silva, Carlos Eduardo; da Silva, Vinicius Duval; da Silva, Jefferson Luis Braga

    2014-08-01

    Objective The identification of cranial nerves is one of the most challenging goals in the dissection of skull base meningiomas. The authors present an application of sodium fluorescein (SF) in skull base meningiomas with the purpose of improving the identification of cranial nerves. Design A prospective study within-subjects design. Setting Hospital Ernesto Dornelles, Porto Alegre, Brazil. Participants Patients with skull base meningiomas. Main Outcomes Measures Cranial nerve identification. Results The group of nine meningiomas was composed of one cavernous sinus, three petroclival, one tuberculum sellae, two sphenoid wing, one olfactory groove, and one temporal floor meningioma. The SF enhancement in all tumors was strong, and the contrast with cranial nerves clearly evident. There were one definite olfactory nerve deficit, one transient abducens deficit, and one definite hemiparesis. All lesions were resected (Simpson grades 1 and 2). The analysis of the difference of the delta SF wavelength between the meningiomas and cranial nerve contrast was performed by the Wilcoxon signed rank test and showed p = 0.011. Conclusions The contrast between the enhanced meningiomas and cranial nerves was evident and assisted in the visualization and microsurgical dissection of these structures. The anatomical preservation of these structures was improved using the contrast.

  10. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  11. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  12. MR inflow angiography for the evaluation of dural sinus patency

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriaux, D.; Grand, C.; Van Dijk, P.; De Graaf, R.; Segebarth, C.

    1990-01-01

    This paper assesses dural sinus patency with two-dimensional inflow MR angiography. Twelve patients with potential dural sinus (superior sagittal and transverse sinus) involvement related to tumors of the falx or the convexity (meningiomas, metastasis) were examined with digital subtraction angiography (DSA), Mr imaging (1.5-T Gyroscan system), including T1-weighted (pre- and post-agadolinium) and T2-weighted spin-echo imaging, and MR angiography. For the MR angiographic study, a gradient-echo fast field echo sequence with flow compensation was used. Thin (2-mm), contiguous coronal or transverse sections were acquired sequentially. Three-dimensional reconstruction with MIP processing was then performed. CT, DSA, and MR imaging were performed for presurgical evaluation. Surgical confirmation of sinus patency was obtained for all patients

  13. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  14. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  15. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  16. Nosocomial septicemia and therapeutic angiography. Report of four cases

    International Nuclear Information System (INIS)

    Meyer, Ph.; Reizine, D.; Merland, J.J.; Guerin, J.M.

    1988-01-01

    Therapeutic angiography may be responsible for rare, but serious infectious complications.The authors report 4 cases occurring immediately following angiography. Three modes of contamination are proposed. Contamination by material used during the angiography is due to multiresistant hospital organisms. Penetration of cutaneous organisms into the circulation from the puncture site and bacterial contamination of a focus of tissue necrosis distal to the embolisation explain the other cases. Curative treatment is difficult because of the possibility of contamination of the embolisation material. Prophylactic treatment is essential and consists of respect of the rules of surgical asepsis, bacteriological control of the fluids used and eradication of adjacent septic foci. Routine antibiotic prophylaxis has yet to be evaluated [fr

  17. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  18. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  19. MR angiography of the TMJ in asymptomatic volunteers

    International Nuclear Information System (INIS)

    Takagi, Ritsuo; Ohashi, Yasushi; Westesson, P.L.; Togashi, Hirosuke

    1998-01-01

    To evaluate the vascular anatomy of the temporomandibular joint (TMJ) and surrounding soft tissue non-invasively, we applied magnetic resonance (MR) angiography for delineating the arterial architecture around the TMJ. MR angiograms of the left and right TMJs in asymptomatic volunteers were obtained using 3D/Time-of-flight (TOF) (First Field Echo, TR/TE/FLIP=46 ms/6.8 ms/17 deg) with intravenous contrast. These MR angiograms were compared with experimental angiograms of human TMJ autopsy specimens in order to identify each of the branches of the arteries on the MR angiograms. This study enabled the depiction by MR angiography of arterial vessels around the TMJ region to some degree. In conclusion, MR angiography appears promising as a non-invasive tool to evaluate the vascular anatomy of the TMJ. (author)

  20. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  1. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  2. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  3. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  4. Comparison of MR angiography with conventional angiography in cervical and intracranial vascular disease

    International Nuclear Information System (INIS)

    Choi, D. S.; Chang, K. H.; Jung, H. W.; Han, M. H.

    1995-01-01

    To assess the usefulness of magnetic resonance angiography (MRA) in evaluation of stenosis of carotid and large cerebral vessels and cerebral aneurysm. Twenty-seven patients with either arterial stenosis in cervical or intracranial major vessels (n = 18) or cerebral aneurysm (n = 8) or both (n 1) were examined with both MRA and conventional angiography (CA). MRA was performed with 3D TOF technique with magnetization transfer suppression at 1.5T system (Magnetom, Siemens, Germany); both intracranial MRA and cervical MRA in 16 patients, intracranial MRA only in the remaining patients. For evaluation of arterial stenosis, 32 carotid bifurcations and 383 segments of intracranial major vessels were assessed in blind fashion, and were compared with those of CA. Each arterial segment was arbitrarily classified into one of five grades (< 10, 10-49, 50-74, 75-99, 100%) for carotid bifurcation and one of four (< 10, 10-49, 50-99, 100%) for intracranial vessels. For aneurysm, its location, size shape and direction were compared. For arterial stenosis, concordance rate between MRA and CA was 88% (28/32) in carotid bifurcation and 89% (340/383) in intracranial vessels. All discordant cases were overgraded on MRA. For aneurysm, 7 of 9 were demonstrated on both MRA and CA, one of which was partially demonstrated on MRA. One of the other two patients showed aneurysm only on MRA, whereas the remaining one revealed aneurysm only on CA. MRA may be performed as a screening test for occlusive disease of cervical and major intracranial vessels and cerebral aneurysm

  5. Diagnosis of echinococcosis of the liver by angiography

    International Nuclear Information System (INIS)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.; Katharinenhospital, Stuttgart

    1980-01-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up. (orig.) [de

  6. Diagnosis of echinococcosis of the liver by angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.

    1980-07-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up.

  7. Dosimetry Measurements around the Angiography Units Using Thermoluminescence Detectors (TLD)

    International Nuclear Information System (INIS)

    Salah El-den, T.; Shahein, A.Y.; Gomaa, M.A.

    2008-01-01

    The thermoluminescent dosimeters (TLDs) are widely used not only in the field of personnel monitoring (dosimetry) service for ionizing radiation to medical, and research communities, but also for measurements of X-rays emitted from different angiography's unit. Measurements ionizing radiation around the bed area during cardiac catheterization procedures using X-rays was measured. TLD Badges used to determine the annual effective doses, the safe distance for the staff to minimize radiation exposure and the effectiveness of shield and used leaded apron. The results indicated that annual effective dose for by angiography cardiac Catheterization room may exceed the limits

  8. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Tonino, Pim A L; De Bruyne, Bernard; Pijls, Nico H J

    2009-01-01

    of maximal blood flow in a stenotic artery to normal maximal flow), in addition to angiography, improves outcomes. METHODS: In 20 medical centers in the United States and Europe, we randomly assigned 1005 patients with multivessel coronary artery disease to undergo PCI with implantation of drug......BACKGROUND: In patients with multivessel coronary artery disease who are undergoing percutaneous coronary intervention (PCI), coronary angiography is the standard method for guiding the placement of the stent. It is unclear whether routine measurement of fractional flow reserve (FFR; the ratio...

  9. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  10. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R F; Seeger, J F; Smith, R L; Horsley, W W; Miller, R W

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  11. Digital subtraction angiography for breast diseases

    International Nuclear Information System (INIS)

    Okuyama, Nobuo; Okamoto, Yasushi; Kurita, Minoru; Nonaka, Naomichi; Ozawa, Yoshiyuki; Tsurumi, Kiyohiko

    1986-01-01

    We performed digital subtraction angiography (DSA) via arteries (IA-DSA) and veins (IV-DSA) on 42 patients with breast diseases to investigate its availability. The findings by DSA in cases with breast cancer included: tumor stains, hypervascularity and tortuosity, enlarged blood vessels, encasement and pooling. Metastatic lymph nodes and daughter nodules were also recognized by DSA. In benign tumors of the breast, a tumor stain was observed only in one case of fibroadenoma; otherwise no remarkable changes were noticed. The incidence of signs in cases with breast cancer using IA-DSA was 65 % for hypervascularity, 59 % for tumor stain, 41 % for vascular tortuosity and 41 % for enlargement of vessels. IV-DSA, on the contrary, revealed less incidences. However, tumor stain was seen frequently, and hypervascularity was seldom observed. The number of signs out of the abovementioned six appearing in each case was tabulated. With IA-DSA, there were 5 signs noted in 2 cases, but the majority had fewer: 4 cases in 4 cases and only 2 signs in 4 cases. There were no signs evident in 18 % of the cases. The incidence of the appearance of signs with IV-DSA was lower: there were no signs in 36 % of the cases. Therefore, the diagnostic accuracy of IA-DSA seemed to be fairly good in comparison with that of IV-DSA. The rate of appearance of abnormal signs was also examined, according to the size of the tumors. In IA-DSA, T 1 breast cancers revealed malignant signs in 80 % of the cases, in T 2 there were such signs 75 % and 100 % of the T 3 cases exhibited malignant signs, for an overall average of 82 %. In IV-DSA, T 1 showed 33 %, T 2 showed 70 %, and T 3 , 1 out of 1 case, showed malignant signs, 64 % altogether. It was the bigger the tumor, the larger the number of signs. The smallest breast cancer that exhibited abnormality in DSA was 1.0 x 0.7 cm in size. (J.P.N.)

  12. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    Science.gov (United States)

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  13. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  14. Sensitive determination of 4-nitrophenol based on its enhancement of a peroxyoxalate chemiluminescence system containing graphene oxide quantum dots and fluorescein

    International Nuclear Information System (INIS)

    Chen, Donghua; Peng, Rulin; Zhou, Hong; Liu, Hui

    2016-01-01

    Graphene oxide quantum dots (GOQD) are capable of enhancing the green chemiluminescence (CL) of the system composed of bis (2,4,6-trichlorophenyl) oxalate, hydrogen peroxide and fluorescein (TCPO/H_2O_2/fluorescein). It was found that 4-nitrophenol (4-NP) causes a further enhancement of the system, and this was exploited to develop a CL detection scheme for 4-NP. The optimum reaction concentrations were established, and under these conditions the calibration plot is linear in the 1.0 to 300 pmol L"−"1 concentration range, with a 0.3 pmol L"−"1 detection limit (at 3σ).We assume that CL enhancement is due to energy transfer from GOQD to fluorescein which is promoted by the interaction of 4-NP with the GOQD. The method was applied to the determination of 4-NP in spiked tap water and river water and gave recoveries between 93.4 and 107.9 %, with relative standard deviations of <4.0 %. (author)

  15. Symptomatic middle cerebral artery stenosis and occlusion. Comparison of three-dimensional time-of-flight magnetic resonance angiography with conventional angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Motoshi; Yano, Hirohito; Shinoda, Jun; Funakoshi, Takashi [Daiyukai General Hospital, Ichinomiya, Aichi (Japan); Kumagai, Morio

    1994-10-01

    The usefulness of magnetic resonance (MR) angiography using the three-dimensional time-of-flight method for the characterization of symptomatic middle cerebral artery (MCA) occlusive lesions was evaluated in 10 patients with MCA occlusion and 10 with MCA stenosis. All lesions were symptomatic and documented by conventional angiography. There was no false-negative MR angiogram that failed to demonstrate the MCA occlusive lesion. MR angiography correctly evaluated the location of lesions and the difference between stenosis and occlusion. Stenosis appeared as a focal signal loss (<1.0cm) of the MCA at the site of stenosis, and occlusion as a complete signal loss of the MCA distal to the site of occlusion. However, MR angiography could not distinguish diffuse stenosis and one point stenosis demonstrated by conventional angiography. MR angiography is a useful noninvasive diagnostic method for evaluating occlusive lesions of the MCA in symptomatic patients. (author).

  16. A new method to measure intestinal secretion using fluorescein isothiocyanate-inulin in small bowel of rats.

    Science.gov (United States)

    Munoz-Abraham, Armando Salim; Judeeba, Sami; Alkukhun, Abedalrazaq; Alfadda, Tariq; Patron-Lozano, Roger; Rodriguez-Davalos, Manuel I; Geibel, John P

    2015-08-01

    Small intestine ischemia can be seen in various conditions such as intestinal transplantation. To further understand the pathologic disruption in ischemia-reperfusion injury, we have developed a method to measure fluid changes in the intestinal lumen of rats. Two 10-cm rat intestine segments were procured, connected to the terminal apertures of a perfusion device, and continuously infused with 3 mL of HEPES solution (control solution) containing 50 μM of fluorescein isothiocyanate (FITC)-inulin. The perfusion device consists of concentric chambers that contain the perfused bowel segments, which are maintained at 37°C via H₂O bath. The individual chamber has four apertures as follows: two fill and/or drain the surrounding HEPES solution on the blood side of the tissue. The others provide flow of HEPES solution containing FITC-inulin through the lumens. The experimental intestine was infused with the same solution with 100 μM of Forskolin. A pump continuously circulated solutions at 6 mL/min. Samples were collected at 15-min intervals until 150 min and were measured by the nanoflourospectrometer. A mean of 6-μM decrease in the FITC-inulin concentration in the Forskolin-treated experimental intestine was observed in comparison with that in the control intestine. The FITC-inulin count dilution in the experimental intestine is a result of an increase of fluid secretion produced by the effect of Forskolin, with P values inulin to allow real-time determinations of fluid and/or electrolyte movement along the small intestine. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Classification of phytoplankton cells as live or dead using the vital stains fluorescein diacetate and 5-chloromethylfluorescein diacetate.

    Science.gov (United States)

    MacIntyre, Hugh L; Cullen, John J

    2016-08-01

    Regulations for ballast water treatment specify limits on the concentrations of living cells in discharge water. The vital stains fluorescein diacetate (FDA) and 5-chloromethylfluorescein diacetate (CMFDA) in combination have been recommended for use in verification of ballast water treatment technology. We tested the effectiveness of FDA and CMFDA, singly and in combination, in discriminating between living and heat-killed populations of 24 species of phytoplankton from seven divisions, verifying with quantitative growth assays that uniformly live and dead populations were compared. The diagnostic signal, per-cell fluorescence intensity, was measured by flow cytometry and alternate discriminatory thresholds were defined statistically from the frequency distributions of the dead or living cells. Species were clustered by staining patterns: for four species, the staining of live versus dead cells was distinct, and live-dead classification was essentially error free. But overlap between the frequency distributions of living and heat-killed cells in the other taxa led to unavoidable errors, well in excess of 20% in many. In 4 very weakly staining taxa, the mean fluorescence intensity in the heat-killed cells was higher than that of the living cells, which is inconsistent with the assumptions of the method. Applying the criteria of ≤5% false negative plus ≤5% false positive errors, and no significant loss of cells due to staining, FDA and FDA+CMFDA gave acceptably accurate results for only 8-10 of 24 species (i.e., 33%-42%). CMFDA was the least effective stain and its addition to FDA did not improve the performance of FDA alone. © 2016 The Authors. Journal of Phycology published by Wiley Periodicals, Inc. on behalf of Phycological Society of America.

  18. Fluorescein isothiocyanate labeled, magnetic nanoparticles conjugated D-penicillamine-anti-metadherin and in vitro evaluation on breast cancer cells

    International Nuclear Information System (INIS)

    Akca, Ozlet; Unak, Perihan; Medine, E. Ylker; Sakarya, Serhan; Ozdemir, Caglar; Timur, Suna

    2011-01-01

    Silane modified magnetic nanoparticles were prepared after capped with silica generated from the hydrolyzation of tetraethyl orthosilicate (TEOS). Amino silane (SG-Si900) was added to this solution for surface modification of silica coated magnetic particles. Finally, D-penicillamine (D-PA)-antimetadherin (anti-MTDH) was covalently linked to the amine group using glutaraldehyde as cross-linker. Magnetic nanoparticles were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and atomic force microscopy (AFM). AFM results showed that particles are nearly monodisperse, and the average size of particles was 40 to 50 nm. An amino acid derivative D-PA was conjugated anti-MTDH, which results the increase of uptaking potential of a conjugated agent, labelled fluorescein isothiocyanate (FITC) and then conjugated to the magnetic nanoparticles. In vitro evaluation of the conjugated D-PA-anti-MTDH-FITC to magnetic nanoparticle was studied on MCF-7 breast cancer cell lines. Fluorescence microscopy images of cells after incubation of the sample were obtained to monitor the interaction of the sample with the cancerous cells. Incorporation on cells of FITC labeled and magnetic nanoparticles conjugated D-PA-anti-MTDH was found higher than FITC labeled D-PA-anti-MTDH. The results show that magnetic properties and application of magnetic field increased incorporation rates. The obtained D-PA-anti-MTDH-magnetic nanoparticles-FITC complex has been used for in vitro imaging of breast cancer cells. FITC labeled and magnetic nanoparticles conjugated D-PA-anti-MTDH may be useful as a new class of scintigraphic agents. Results of this study are sufficiently encouraging to bring about further evaluation of this and related compounds for ultraviolet magnetic resonance (UV-MR) dual imaging. (author)

  19. Evaluation of field-collected data measuring fluorescein dye movements and dispersion for dispersed oil transport modeling

    Energy Technology Data Exchange (ETDEWEB)

    French McCay, D.; Mueller, C.; Jayko, K.; Longval, B.; Schroeder, M. [Applied Science Associates Inc., Narragansett, RI (United States); Terrill, E.; Carter, M.; Otero, M.; Kim, S.Y. [Scripps Inst. of Oceanography, La Jolla, CA (United States); Nordhausen, W.; Lampinen, M. [California Dept. of Fish and Game, San Diego, CA (United States). Office of Spill Prevention and Response; Payne, J.R. [Payne Environmental Consultants Inc., Encinitas, CA (United States); Ohlmann, C. [California Univ., Santa Barbara, CA (United States)

    2007-07-01

    In the event of on oil spill at sea, the concentration of hydrocarbons in the water column can be evaluated using oil spill fate and transport modeling. Such modeling can also determine the potential exposure to zooplankton, and the impacts of oil spills with and without the use of dispersants. This paper reported on fluorescein dye studies that were conducted off Sand Diego, California to evaluate the ability of transport models to hindcast movement and dispersion of dye using data such as surface currents calculated from high-frequency radar; near surface currents from drifter measurements drogued at several depths; dye concentrations measured by fluorescence; spreading and dye intensity measurements based on aerial photography; and, water density profiles from conductivity-temperature-depth (CTD) casts. This paper presented modeling issues that remain to be addressed, such as the need to resolve small-scale transport processes in order to evaluate effects on water column biota. Since these processes determining current velocities are complex, it is not feasible to include most of the complexities at appropriately small scales in oil spill modeling applications. The difficulty in predicting currents that transport oil components and organisms with a hydrodynamic model application that does not include temporal details in the forcing function was also discussed. This paper demonstrated that the SIMAP spill trajectory model, using the drifter velocities as current input, successfully reproduced trajectories of the dye. The effect of wind drift transporting the surface material faster than the subsurface materials was identified as a spreading mechanism. Therefore, subtraction of the wind drift from the shallower drifter velocities, and inclusion of wind drift in SIMAP would allow those velocities to be used for depths other than those tracked by the drifters. 57 refs., 8 tabs., 17 figs.

  20. Fluoresceination of FepA during colicin B killing: effects of temperature, toxin and TonB.

    Science.gov (United States)

    Smallwood, Chuck R; Marco, Amparo Gala; Xiao, Qiaobin; Trinh, Vy; Newton, Salete M C; Klebba, Phillip E

    2009-06-01

    We studied the reactivity of 35 genetically engineered Cys sulphydryl groups at different locations in Escherichia coli FepA. Modification of surface loop residues by fluorescein maleimide (FM) was strongly temperature-dependent in vivo, whereas reactivity at other sites was much less affected. Control reactions with bovine serum albumin showed that the temperature dependence of loop residue reactivity was unusually high, indicating that conformational changes in multiple loops (L2, L3, L4, L5, L7, L8, L10) transform the receptor to a more accessible form at 37 degrees C. At 0 degrees C colicin B binding impaired or blocked labelling at 8 of 10 surface loop sites, presumably by steric hindrance. Overall, colicin B adsorption decreased the reactivity of more than half of the 35 sites, in both the N- and C- domains of FepA. However, colicin B penetration into the cell at 37 degrees C did not augment the chemical modification of any residues in FepA. The FM modification patterns were similarly unaffected by the tonB locus. FepA was expressed at lower levels in a tonB host strain, but when we accounted for this decrease its FM labelling was comparable whether TonB was present or absent. Thus we did not detect TonB-dependent structural changes in FepA, either alone or when it interacted with colicin B at 37 degrees C. The only changes in chemical modification were reductions from steric hindrance when the bacteriocin bound to the receptor protein. The absence of increases in the reactivity of N-domain residues argues against the idea that the colicin B polypeptide traverses the FepA channel.

  1. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E. [Department of Radiology, Children`s Hospital Medical Center, Boston, MA (United States); Eldredge, E.A. [Department of Anesthesia, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States); Scott, R.M. [Department of Neurosurgery, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States)

    1998-11-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher`s exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.) With 8 tabs., 37 refs.

  2. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    International Nuclear Information System (INIS)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E.; Eldredge, E.A.; Scott, R.M.

    1998-01-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher's exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.)

  3. Clinical application of pelvic MR angiography for gynecologic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Takeshi [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1996-08-01

    Magnetic resonance (MR) imaging is the second most important method next to the ultrasound for the diagnosis of gynecological disorders. MR angiography provides a new noninvasive method for evaluating vascular occlusive disease of the lower extremities and the branches of abdominal aorta. To our knowledge, no determinant of efficacy of MR angiography and images of gynecological diseases have yet been made. Maximum intensity projection image was obtained from the data set by the three dimensional contrast enhanced MR angiography (3D-CE MRA) with newly designed fat suppression method. MR angiogram reveals well visualization of lower abdominal aorta and its branches. Furthermore, uterine arteries were identified in 49.3% of the cases, branching from the internal iliac artery. Leiomyoma of the uterus showed an enhanced uterus in 53.7% of the eases. All cases of endometriosis demonstrated a homogeneous, high signal intensity being a specific finding. In conclusion, maximum intensity projection image of pelvis showed a good visualization of the lower abdominal aorta and its branches. Uterine artery and, in a few cases, ovarian artery can be demonstrated on MR angiography. All cases of endometriosis showed a significant, high signal intensity. This technique is noninvasive and be a supplementary method for diagnosis and follow up of vasculature of gynecological disorders. (author)

  4. Use of digital subtraction angiography for renal transplant evaluation

    International Nuclear Information System (INIS)

    Fanucci, E.; Orlacchio, A.; Pocek, M.; Svegliati, F.

    1986-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 6 renal allograft recipients and 3 potential renal donors. In 4 potential renal donors and in 2 allograft recipients, angiographic data were confirmed by surgery. IVDSA is a safe, accurate, easily performed, outpatient procedure; in our opinion DSA should became the procedure of choice to study vascular anatomy in renal transplant evaluation

  5. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    Science.gov (United States)

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (pdiabetes duration (pdiabetic retinopathy compared to control subjects (pdiabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  6. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  7. Clinical application of pelvic MR angiography for gynecologic diseases

    International Nuclear Information System (INIS)

    Ohnishi, Takeshi

    1996-01-01

    Magnetic resonance (MR) imaging is the second most important method next to the ultrasound for the diagnosis of gynecological disorders. MR angiography provides a new noninvasive method for evaluating vascular occlusive disease of the lower extremities and the branches of abdominal aorta. To our knowledge, no determinant of efficacy of MR angiography and images of gynecological diseases have yet been made. Maximum intensity projection image was obtained from the data set by the three dimensional contrast enhanced MR angiography (3D-CE MRA) with newly designed fat suppression method. MR angiogram reveals well visualization of lower abdominal aorta and its branches. Furthermore, uterine arteries were identified in 49.3% of the cases, branching from the internal iliac artery. Leiomyoma of the uterus showed an enhanced uterus in 53.7% of the eases. All cases of endometriosis demonstrated a homogeneous, high signal intensity being a specific finding. In conclusion, maximum intensity projection image of pelvis showed a good visualization of the lower abdominal aorta and its branches. Uterine artery and, in a few cases, ovarian artery can be demonstrated on MR angiography. All cases of endometriosis showed a significant, high signal intensity. This technique is noninvasive and be a supplementary method for diagnosis and follow up of vasculature of gynecological disorders. (author)

  8. 64-MDCT angiography of blunt vascular injuries of the neck.

    Science.gov (United States)

    Chokshi, Falgun H; Munera, Felipe; Rivas, Luis A; Henry, Robert P; Quencer, Robert M

    2011-03-01

    CT angiography (CTA) using 64-MDCT enables timely evaluation of injuries associated with blunt neck trauma. The purpose of this article is to familiarize the reader with the most frequent CTA signs of blunt vascular injury. CTA is a valuable tool to detect blunt vascular injuries, especially using its multiplanar and 3D reconstruction capabilities.

  9. Digital subtraction angiography in the diagnosis of Fallot's tetralogy

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Tereshkin, Ya.A.; Sobolev, A.V.; Stolyar, V.L.; Slyunyastikov, M.A.

    1995-01-01

    The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplity and cut down their scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. 5 refs.; 6 figs

  10. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  11. Hyperacute unilateral contrast-induced parotiditis during cerebral angiography

    Directory of Open Access Journals (Sweden)

    Song J. Kim, MD

    2018-02-01

    Full Text Available An uncommon complication of iodinated contrast administration is the development of bilateral sialadenitis. We report a unique case of hyperacute unilateral parotiditis during diagnostic cerebral angiography of the external carotid artery, which mimicked possible iatrogenic vascular event associated with cerebral endovascular procedures. Discussion includes the differential diagnosis, diagnostic studies, and treatments for this unusual condition.

  12. MR imaging and MR angiography in popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Atilla, S.; Akpek, S.; Yuecel, C.; Tali, E.T.; Isik, S.; Ilgit, E.T.

    1998-01-01

    Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome. (orig.)

  13. The value of abdominal angiography in Turner's syndrome

    International Nuclear Information System (INIS)

    Barreto, A.; Castaneda-Zuniga, W.R.; Velasquez, G.; Zollikofer, C.; Amplatz, K.

    1981-01-01

    In patients with Turner's syndrome, there is a relatively high incidence of gastrointestinal bleeding due to telangiectasias of the intestine. Despite the importance of preoperative diagnosis of the lesion in planning surgical treatment. The related angiographic findings have never been reported. We have studied one patient in whom the diagnosis was established by preoperative angiography. (orig.)

  14. Clinical application of iopamidol (pamiray 300) for cerebral angiography

    International Nuclear Information System (INIS)

    Park, Sung Ho; Suh, Sang Hyun; Kim, Jin Na; Kim, Eung Yeop; Kim, Dong Joon; Lee, Seung Koo; Kim, Dong Ik

    2007-01-01

    The aim of this study was to assess the clinical safety and efficacy of Pamiray 300 (Iopamidol; Dongkook Pharm, Seoul, Korea) as a nonionic contrast medium for cerebral angiography. One hundred patients undergoing cerebral angiography were randomly assigned to receive Pamiray 300 after written consent had been obtained. Patients with adverse reactions were divided into two groups. One group consisted of patients with minor adverse events such as heat sensation and pain, and the other group consisted of patients with major adverse events such as dyspnea, laryngeal edema and shock. The qualities of the radiographic images were stratified into five grades by three independent radiologists. No abnormality induced by Pamiray 300 was seen by a physical and neurological examination, blood pressure measurement, electrocardiogram, respiration rate measurement and partial fraction of arterial oxygen recording. No major and severe adverse events occurred throughout the study. Patient sex, age, disease category, underlying disease and administered contrast dosage showed no statistical significance with regards to the occurrence of adverse events. The opacification of blood vessels in all patients was 'good' or 'excellent'. Based on the results of this study, Pamiray 300 is a safe, efficacious and well-tolerated contrast medium for use in cerebral angiography. Thus, Pamiray 300 can be used as a competitive medium in cerebral angiography

  15. Clinical application of iopamidol (pamiray 300) for cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Ho; Suh, Sang Hyun; Kim, Jin Na; Kim, Eung Yeop; Kim, Dong Joon; Lee, Seung Koo; Kim, Dong Ik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-08-15

    The aim of this study was to assess the clinical safety and efficacy of Pamiray 300 (Iopamidol; Dongkook Pharm, Seoul, Korea) as a nonionic contrast medium for cerebral angiography. One hundred patients undergoing cerebral angiography were randomly assigned to receive Pamiray 300 after written consent had been obtained. Patients with adverse reactions were divided into two groups. One group consisted of patients with minor adverse events such as heat sensation and pain, and the other group consisted of patients with major adverse events such as dyspnea, laryngeal edema and shock. The qualities of the radiographic images were stratified into five grades by three independent radiologists. No abnormality induced by Pamiray 300 was seen by a physical and neurological examination, blood pressure measurement, electrocardiogram, respiration rate measurement and partial fraction of arterial oxygen recording. No major and severe adverse events occurred throughout the study. Patient sex, age, disease category, underlying disease and administered contrast dosage showed no statistical significance with regards to the occurrence of adverse events. The opacification of blood vessels in all patients was 'good' or 'excellent'. Based on the results of this study, Pamiray 300 is a safe, efficacious and well-tolerated contrast medium for use in cerebral angiography. Thus, Pamiray 300 can be used as a competitive medium in cerebral angiography.

  16. Digital subtraction angiography (DSA) of the heart and coronary arteries

    International Nuclear Information System (INIS)

    Struyven, J.J.; Delcour, C.; Brion, J.P.; Vandenbosch, G.; Claessens, J.

    1986-01-01

    Digital subtraction angiography has potential advantages over conventional radiography. The removal of background structures makes possible to visualize chambers of the heart, great vessels and coronary arteries with a lower iodine signal than with conventional cineangiography. Digital data used for imaging can been manipulated for assessment and quantitation of the ventricular fonction and the coronary circulation

  17. Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    NARCIS (Netherlands)

    Smit, Jeroen M.; Dimopoulou, Angeliki; Liss, Anders G.; Zeebregts, Clark J.; Kildal, Morten; Whitaker, Iain S.; Magnusson, Anders; Acosta, Rafael

    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in

  18. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  19. Mono-energy coronary angiography with a compact light source

    Science.gov (United States)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  20. Evaluation of angiography performed by radiographers and nurses

    International Nuclear Information System (INIS)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A.

    2002-01-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  1. Diagnosis of arterial sequestration using multidetector CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Li Huimin, E-mail: lihuiminphd@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China)

    2010-11-15

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  2. Diagnosis of arterial sequestration using multidetector CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  3. 2D MR angiography of the aortic aneurysm

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1992-01-01

    2D time-of-flight MR angiography was performed in 6 cases of thoracic aortic aneurysm. Oblique saturation pulses were used to suppress the signals of the pulmonary artery and SVC, providing excellent selective MR aortograms. Three dimensional extension of the aneurysm and its relation with cervical branches were easily assessed. It could be possible to replace invasive aortography by this technique. (author)

  4. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  5. Clinical Assessment of a New Stereoscopic Digital Angiography System

    International Nuclear Information System (INIS)

    Moll, Thierry; Douek, Philippe; Finet, Gerard; Turjman, Francis; Picard, Catherine; Revel, Didier; Amiel, Michel

    1998-01-01

    Purpose: To assess the clinical feasibility of an experimental modified angiographic system capable of real-time digital stereofluoroscopy and stereography in X-ray angiography, using a twin-focus tube and a stereoscopic monitor. Methods: We report the experience obtained in 37 patients with a well-documented examination. The patients were examined for coronary angiography (11 cases), aortography (7 cases), pulmonary angiography (6 cases), inferior vena cava filter placement (2 cases), and cerebral angiography (11 cases). Six radiologists were asked to use stereoscopic features for fluoroscopy and angiography. A questionnaire was designed to record their subjective evaluation of stereoscopic image quality, ergonomics of the system, and its medical interest. Results: Stereofluoroscopy was successfully used in 25 of 37 cases; diplopia and/or ghost images were reported in 6 cases. It was helpful for aortic catheterization in 10 cases and for selective catheterization in 5 cases. In stereoangiography, depth was easily and accurately perceived in 27 of 37 cases; diplopia and/or ghost images were reported in 4 cases. A certain gain in the three-dimensional evaluation of the anatomy and relation between vessels and lesions was noted. As regards ergonomic considerations, polarized spectacles were not considered cumbersome. Visual fatigue and additional work were variously reported. Stereoshift tuning before X-ray acquisition was not judged to be a limiting factor. Conclusion: A twin-focus X-ray tube and a polarized shutter for stereoscopic display allowed effective real-time three-dimensional perception of angiographic images. Our clinical study suggests no clear medical interest for diagnostic examinations, but the field of interventional radiology needs to be investigated

  6. Incidence of ischemic lesions in diffusion-weighted imaging after transbrachial digital subtraction angiography

    International Nuclear Information System (INIS)

    Aschenbach, R.; Majeed, A.; Eger, C.; Basche, S.; Kerl, J.M.; Vogl, T.J.

    2008-01-01

    Purpose: to evaluate the frequency of ischemia after transbrachial digital subtraction angiography under ambulant conditions using diffusion-weighted imaging. Materials and methods: 200 patients were included in a prospective study design and received transbrachial digital subtraction angiography under ambulant conditions. Before and after digital subtraction angiography, diffusion-weighted imaging of the brain was performed. Results: in our study population no new lesions were found in diffusion-weighted imaging after digital subtraction angiography during the 3-hour window after angiography. One new lesion was found 3 days after angiography as a late onset complication. Therefore, the frequency of neurological complications is at the level of the confidence interval of 0 - 1.5%. Conclusion: the transbrachial approach under ambulant conditions is a safe method for digital subtraction angiography resulting in a low rate of ischemic lesions in diffusion-weighted imaging. (orig.)

  7. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  8. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    International Nuclear Information System (INIS)

    Patrux, B.; Laissy, J.P.; Jouini, S.; Kawiecki, W.; Coty, P.; Thiebot, J.

    1994-01-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  9. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Patrux, B. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Laissy, J.P. (Neuroradiology, CHU Charles Nicolle, Rouen (France) Dept. of Radiology, CHU Bichat, Paris (France)); Jouini, S. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Kawiecki, W. (Siemens Medical Systems, Saint-Denis (France)); Coty, P. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Thiebot, J. (Neuroradiology, CHU Charles Nicolle, Rouen (France))

    1994-04-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  10. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  11. Assessment of left ventricular volumes by magnetic resonance in comparison with radionuclide angiography, contrast angiography and echocardiography

    DEFF Research Database (Denmark)

    Møgelvang, J; Stokholm, K H; Saunamäki, K

    1992-01-01

    The present study shows that for assessment of LVEF, MRI and the standard methods seem to provide information of similar value. For absolute volume measurements, MRI and RNA are superior to single plane angiography and 2 DE using the modified Simpson-rule. The time consuming transversal MRI method...... quality, which is crucial especially in dilated ventricles containing stagnant or slowly moving blood....

  12. Value of digital angiography as a substitute for film angiography in comparison with DSA

    International Nuclear Information System (INIS)

    Langer, M.; Mitsch, E.; Zwicker, C.; Scholz, A.; Felix, R.; Langer, R.

    1988-01-01

    The authors performed a prospective study to evaluate whether digital angiography (DA) can provide diagnostic image quality to reduce the need for film studies. The study is based on more than 100 arterial DSA examinations that were intra- and interindividually compared with the DA studies of the same arteries. It was demonstrated that DA with the same quantity of contrast medium as DSA is diagnostic in 80% of cases for abdominal, pelvic, and femoral arteries and in 85% for brachial arteries but in only 56% for carotid arteries if an aortic arch injection is performed. For all examinations, image quality with DSA was excellent in 86%, good in 9%, and diagnostic in 5%, with DA, it was excellent in 5%, good in 49%, diagnostic in 22%, and bad in 24% (90% of these were supraaortic studies). The results of this study indicate that it is worth trying a DA study when DSA is nondiagnostic because of artifacts, if a selective intraarterial contrast medium injection can be performed

  13. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  14. Molecular imaging of a cell-penetrating peptide labeled fluorescein-5-isothiocyanate and MR contrast agents: gadopentetate dimeglumine

    International Nuclear Information System (INIS)

    Liu Min; Guo Youmin; Duan Xiaoyi; Guo Xiaojuan; Yang Junle; Xu Min

    2006-01-01

    Objective: To study the value of a new intracellular contrast agent--cell penetrating peptide labeled Fluorescein-5-isothiocyanate (FITC) and MRI contrast agent, Gadopentetate dimeglumine in molecular imaging. Methods: A new cell penetration peptides (CPPs)sequence LAGRRRRRRRRRK were synthesized in solid phase on the base of arginine (9) and were labelled with FITC (CPP 13 -FITC) and Gd - DTPA (CPP 13 -DTPA-Gd). Hepatic carcinoma cell line-HEPG 2 and mouse bone marrow stem cell was respectively stained by CPP 13 -FITC for different time intervals for observing the uptake and intracellular distribution. HEPG 2 in three l00 mm 2 culture plates was respectively incubated with CPP 13 -DTPA-Gd, Gd- DTPA and Dulbecco minimum essential medium for 30 min and imaged by 1.5 T MRI for studying the intracellular uptake and T 1 WI signal characteristics. Results: The peptide was synthesized by the manual solid-phase method successfully. The calculated molecular weight was 1792.78 and the chemical purity was over 95%. By inverted fluorescence microscope, HEPG 2 and mouse stem cell could transport CPP-FITC in cytoplasm and nuclear in 10 min. By MR imaging, CPP-DTPA-Gd could be uptake by HEPG 2 in 30 min and had a short T 1 short T 2 signal, furthermore. T 1 WI signal intensity ratio between in-tube (Ii) and out-tube (Io) in three groups of three scan slices were shown below: Iil/Io of group 1 (Group 1 was the cell incubated by CPP 13 -DTPA-Gd ) respectively was 2.84, 2.60, 2. 48; Iil/Io of group 2 (Group 2 was the cell incubated by DTPA-Gd) respectively is 1.15, 1.11, 1.12; Iil/Io of group 3 (Group 3 was the controled cell ) respectively was 1.15, 1.11, 1.11. By ANVOA analysis, the signal intensity among group 1, group 2 and group 3 had significant difference(F (1,2) = 201.88 P (1,3) =206.37 P (2,3) =0.529 P=0.507). Conclusion: The new constructed cell penetration peptide on the base of the polyargnine can translocate cell by carting FITC and MRI contrast agent-DTPA-Gd and the

  15. Distribution of fluorescein sodium and triamcinolone acetonide in the simulated liquefied and vitrectomized Vitreous Model with simulated eye movements.

    Science.gov (United States)

    Stein, Sandra; Bogdahn, Malte; Rosenbaum, Christoph; Weitschies, Werner; Seidlitz, Anne

    2017-11-15

    Intravitreal administration is the method of choice for drug delivery to the posterior segment of the eye with special emphasis on the vitreous body and its surrounding retinal vasculature. In order to gain a better understanding of the underlying distribution processes, an in vitro model simulating the vitreous body (Vitreous Model, VM) and a system simulating the impact of movement on the VM (Eye Movement System, EyeMoS) was previously developed. In the study reported here, these systems were modified in regard to a standardized injection procedure, the diversity of simulated eye movements, extended periods of investigation, the opportunity to simulate the state after vitrectomy and in considering the physiological temperature. Fluorescein sodium (FS) and triamcinolone acetonide (TA) were used as (model) drugs to examine the drug distribution within the VM. Vitrectomy was simulated by replacing half the volume of the polyacrylamide gel that was used as vitreous substitute with the clinically used Siluron® 5000 whereas for a simulated liquefaction half the volume of the gel was replaced by buffer. A simulated liquefaction caused a 12-fold faster distribution of FS compared to the simulated juvenile VM, which was most likely caused by convective forces and mass transfer. Also, the injection technique (injection into the gel or into the buffer compartment) influenced the resulting distribution pattern. Without any liquefaction, the previously described initial injection channel occurred with both (model) drugs and, in the case of TA, remained almost unchanged during the investigation period of 72h. Simulating vitrectomized eyes, TA did not spread uniformly, but either remained in the depot or strongly sedimented within the VM suggesting that a homogenous distribution of a TA suspension is highly unlikely in vitrectomized eyes. High variabilities were observed with ex vivo animal eyes, demonstrating the limited benefit of explanted tissues for such distribution

  16. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  17. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism : a prospective study

    NARCIS (Netherlands)

    Oudkerk, M; van Beek, EJR; Wielopolski, P; van Ooijen, PMA; Brouwers-Kuyper, EMJ; Bongaerts, AHH; Berghout, A

    2002-01-01

    Background Diagnostic strategies for pulmonary embolism are complex and consist of non-invasive diagnostic tests done to avoid conventional pulmonary angiography as much as possible. We aimed to assess the diagnostic accuracy of magnetic resonance angiography (MRA) for the diagnosis of pulmonary

  18. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  19. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  20. Exposed dose comparison between coronary computed tomographic angiography and coronary angiography. Basic examination by phantom

    International Nuclear Information System (INIS)

    Kato, Kyoichi; Takahashi, Yoshimasa; Takahashi, Toshiyuki; Sai, Syogo; Fujimura, Kazumasa; Watanabe, Hiroyuki; Sato, Hisaya; Imai, Yasuhiro; Nakazawa, Yasuo

    2007-01-01

    The new type of coronary angiography (CAG) that uses 40 mm volumetric computed tomography (VCT) has great potential for cardiac disease. However, it is still necessary to be cognizant of exposure dose. We measured doses of CAG by both VCT and cardiovascular X-ray using a body phantom within 170 glass dosimeters. VCT protocols were 120 kV, 570 mA, and 0.35 sec/rot with and without the dose-reduction features (small cardiac X-ray beam filter and electrocardiogram (ECG) mA modulation). The cardiovascular X-ray protocol was Auto (65-77 kV) kV, Auto (41-46 mA) mA, 5 sec x 11 shots + 11 min fluoroscopy (minimum protocol for screening). VCT with and without the dose-reduction features has the same dose distribution, however, the dose-reduction features reduced the amount of dose by about 40-50%. For VCT with those features, measured dose was about 70 mGy in the cardiac area and 60 mGy at the skin of the back, whereas those of cardiovascular X-ray were 10 mGy and 30 mGy. We measured detailed dose distributions and variations in the phantom, and we also demonstrated the possibility of VCT's dose-reduction features. The CT dose was still higher than that of cardiovascular X-ray, however, there were advantages of CT scanning, for instance, information about calcification, soft plaque, and three-dimensional (3D) visualization. We think it is important to use both systems with an understanding of their advantages and limitations. (author)

  1. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  2. Towards the use of OCT angiography in clinical dermatology

    Science.gov (United States)

    Baran, Utku; Choi, Woo June; Wang, Ruikang K.

    2016-02-01

    Optical coherence tomography (OCT) is a popular imaging technique used in ophthalmology, and on the way to become clinically viable alternative in dermatology due to its capability of acquiring histopathology level images of in vivo tissue, noninvasively. In this study, we demonstrate the capabilities of OCT-based angiography (OMAG) in detecting high-resolution, volumetric structural and microvascular features of in vivo human skin with various conditions using a swept source OCT system that operates on a central wavelength of 1310 nm with an A-line rate of 100 kHz. OMAG images provide detailed in vivo visualization of microvasculature of abnormal human skin conditions from face, chest and belly. Moreover, the progress of wound healing on human skin from arm is monitored during longitudinal wound healing process. The presented results promise the clinical use of OCT angiography in treatment of prevalent cutaneous diseases within human skin, in vivo.

  3. Evaluation of the pulmonary vascular bed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Shikuwa, Masahiro; Asai, Sadahiro; Hara, Shiro; Yamasa, Toshihiko; Miyahara, Yoshiyuki; Hara, Kohei; Nishijima, Kyoji.

    1995-01-01

    We studied the usefulness of digital subtraction angiography for evaluating the pulmonary capillary bed. Four individuals underwent the procedure. One was a healthy volunteer and the others were patients with chronic pulmonary emphysema. During catheterization, an 8 F balloon catheter was manipulated into the right pulmonary artery. A total of 20 ml of contrast material was injected at a rate of 10 ml/sec at full inspiration. In the normal subject, the capillary bed filled homogeneously and no defect was seen. In the patients, the pulmonary artery was nearly normal, but severe defects were observed in the pulmonary capillaries. Contrast resolvability was greater with digital subtraction pulmonary angiography than with pulmonary perfusion scintigraphy or pulmonary arteriography. This technique makes possible the visual evaluation of the pulmonary capillary bed. (author)

  4. Identification of arteries and veins in cerebral angiography fluoroscopic images

    Science.gov (United States)

    Andra Tache, Irina

    2017-11-01

    In the present study a new method for pixels tagging into arteries and veins classes from temporal cerebral angiography is presented. This need comes from the neurosurgeon who is evaluating the fluoroscopic angiography and the magnetic resonance images from the brain in order to locate the fistula of the patients who suffer from arterio-venous malformation. The method includes the elimination of the background pixels from a previous segmentation and the generation of the time intensity curves for each remaining pixel. The later undergo signal processing in order to extract the characteristic parameters needed for applying the k-means clustering algorithm. Some of the parameters are: the phase and the maximum amplitude extracted from the Fourier transform, the standard deviation and the mean value. The tagged classes are represented into images which then are re-classified by an expert into artery and vein pixels.

  5. Digital subtraction angiography with an Isocon camera system: clinical applications

    International Nuclear Information System (INIS)

    Barbaric, Z.L.; Gomes, A.S.; Deckard, M.E.; Nelson, R.S.; Moler, C.L.

    1984-01-01

    A new imaging system for digital subtraction angiography (DSA) was evaluated in 30 clinical studies. The image receptor is a 25 X 25 cm, 12 par gadolinium oxysulfate rare-earth screen whose light output is focused to a low-light-level Isocon camera. The video signal is digitized and processed by an image-array processor containing 31 512 X 512 memories 8 bits deep. In most patients, intraarterial DSA studies were done in conjunction with conventional arteriography. In these arterial studies, images adequate to make a specific diagnosis were obtained using half the radiation dose and half the amount of contrast material needed for conventional angiography. In eight intravenous studies performed either to identify renal artery stenosis or for evaluation of congenital heart anomalies, the images were diagnostic but objectionably noisy

  6. Quantification of fluorescence angiography in a porcine model

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Andersen, Helene Schou; Ambrus, Rikard

    2017-01-01

    PURPOSE: There is no consensus on how to quantify indocyanine green (ICG) fluorescence angiography. The aim of the present study was to establish and gather validity evidence for a method of quantifying fluorescence angiography, to assess organ perfusion. METHODS: Laparotomy was performed on seven...... pigs, with two regions of interest (ROIs) marked. ICG and neutron-activated microspheres were administered and the stomach was illuminated in the near-infrared range, parallel to continuous recording of fluorescence signal. Tissue samples from the ROIs were sent for quantification of microspheres...... to calculate the regional blood flow. A software system was developed to assess the fluorescent recordings quantitatively, and each quantitative parameter was compared with the regional blood flow. The parameter with the strongest correlation was then compared with results from an independently developed...

  7. Intravenous digital angiography for the detection of renovascular hypertension

    International Nuclear Information System (INIS)

    Dunnick, N.R.; Svetkey, L.; Braun, S.D.; Cohan, R.H.; Newman, G.E.; Himmelstein, S.I.; Klotman, P.E.

    1987-01-01

    In order to assess the accuracy of intravenous digital subtraction angiography (IV-DSA), the authors prospectively studied all patients referred for suspected renovascular hypertension with IV-DSA and conventional angiography. The IV-DSA study demonstrated renal artery stenosis in 25 patients. A significant main renal artery lesion was confirmed in 21 of these patients while four patients had either normal renal arteries or insignificant changes. The IV-DSA examination was considered negative for renal artery stenosis in 50 patients. This was confirmed in 49 patients, but one patient had a branch renal artery stenosis. The sensitivity of IV-DSA was 96% while the specificity was 93%. The negative predictive value was 98% and the positive predictive value 84%. IV-DSA provides good anatomic definition of the main renal arteries and is sufficiently sensitive to be used as a screening test for renovascular hypertension

  8. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  9. A study of transverse image reconstruction with digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Terasawa, Yuuji; Oda, Masahiko; Gotou, Hiroshi; Nasada, Toshiya; Tanooka, Masao

    1995-01-01

    For digital subtraction angiography (DSA) with C-type equipment, it is possible to radiate an X-ray during rotation and to collect data at different angular settings. We tried to reconstruct transverse image from data obtained by scanning DSA images at different angular settings. 88 projection data were obtained by rotating the object at 180deg during radiation. Reconstruction was made using the convolution method with pixel value distribution for each projection. Similarly, the image quality of the reconstructed images were compared with the unsubtracted and subtracted ones. In case a part object was outside the calculating region, artifacts were generally produced. However, the artifacts were reduced by subtracting the background from the image. In addition, the cupping phenomenon caused by beam hardening was relaxed and high-quality imaging could be achieved. This method will become even more effective, if we will use it with selective angiography in which the limited area is enhanced. (author)

  10. Magnetic Resonance Angiography in the Pig using Hyperpolarized Water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Bowen, Sean; Laustsen, Christoffer

    , the magnetization achievable with hyperpolarized water is superior to other nuclei. Methods A 1 mL sample of 50% water and 50% glycerol with 30 mM TEMPO is polarized in a Spinlab (GE Healthcare) at 5 T, 0.9 K, 139.9 GHz for an hour. The sample is rapidly dissolved in 16 mL deoxygenized dissolution medium (DM......Introduction Magnetic Resonance Angiography (MRA) is an important tool in diagnostics of medical conditions such as emboli, stenosis and aneurysms. Sub-millimetre resolution can be obtained with proton imaging, and further optimization can be obtained with Gd-based blood pool agents1. However......, the acquisition time is several minutes, and conventional MRA methods thus fail to image within a single respiration or heartbeat and therefore suffers from motion artefacts. We demonstrate that hyperpolarized (HP) water can be used as an imaging agent to provide subsecond angiographies in pigs. Previous work...

  11. Atherosclerosis of the carotid artery: evaluation by magnetic resonance angiography.

    Science.gov (United States)

    Wildy, K S; Yuan, C; Tsuruda, J S; Ferguson, M S; Wen, N; Subramaniam, D S; Strandness, D E

    1996-01-01

    Carotid artery atherosclerotic plaques (APs) can lead to brain ischemia, an event shown to correlate with both the degree of stenosis and the composition of the AP. Currently, accurate estimates of stenosis can be obtained by either x-ray angiography or three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA). Our purpose was to determine whether three-dimensional TOF MRA images could also provide information on plaque location, morphology, and composition. Seven pre-endarterectomy patients underwent three-dimensional TOF MRA. After endarterectomy, plaque histology was evaluated. Three-dimensional TOF MRA images contained sufficient soft tissue contrast to differentiate the plaques from the surrounding tissues in all cases. Estimation of plaque morphology had 80% correlation with histology. Finally, intraplaque hemorrhage and calcification were deplicted as regions of moderately high and very low intensity, respectively. These preliminary results suggest that three-dimensional TOF MRA may be useful in studying the development and progression of carotid atherosclerosis.

  12. The need for repeat angiography in subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Urbach, H.; Solymosi, L.; Zentner, J.

    1998-01-01

    This study was designed to assess the necessity for a second angiogram study in patients in whom initial angiography after primary subarachnoid haemorrhage (SAH) was negative. During a 12-year period, 122 of 694 patients (17.5 %) had negative initial angiograms. CT, available for 98 patients, showed a preponderance of subarachnoid blood in the perimesencephalic cisterns in 50 of 73 patients (68.5 %) in whom blood was visible on CT. Angiography, repeated in 67 patients, revealed an aneurysm in 4 (6 %): 2 had an aneurysm of the anterior communicating artery, 1 of the posterior inferior cerebellar artery, and 1 of the P2 segment of the posterior cerebral artery. CT showed subarachnoid blood in the interpeduncular and ambient cisterns in this last case, and a preponderance of subarachnoid blood outside the perimesencephalic cisterns in the remaining 3 patients. (orig.)

  13. The need for repeat angiography in subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H; Solymosi, L [Department of Neuroradiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Zentner, J [Department of Neurosurgery, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    1998-01-01

    This study was designed to assess the necessity for a second angiogram study in patients in whom initial angiography after primary subarachnoid haemorrhage (SAH) was negative. During a 12-year period, 122 of 694 patients (17.5 %) had negative initial angiograms. CT, available for 98 patients, showed a preponderance of subarachnoid blood in the perimesencephalic cisterns in 50 of 73 patients (68.5 %) in whom blood was visible on CT. Angiography, repeated in 67 patients, revealed an aneurysm in 4 (6 %): 2 had an aneurysm of the anterior communicating artery, 1 of the posterior inferior cerebellar artery, and 1 of the P2 segment of the posterior cerebral artery. CT showed subarachnoid blood in the interpeduncular and ambient cisterns in this last case, and a preponderance of subarachnoid blood outside the perimesencephalic cisterns in the remaining 3 patients. (orig.) With 2 figs., 1 tab., 32 refs.

  14. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  15. The use of Metrizamid in experimental renal angiography

    International Nuclear Information System (INIS)

    Pokorny, L.; Kelemen, J.

    1980-01-01

    A possible application of the non-ionizing contrast material metrizamid (Amipaque Vascularsup(R), Amipaquesup(R)) for renal angiography was experimentally investigated in dogs. 1.5, 3, 10 or 25 ml contrast medium was injected into one kidney. The animals were killed immediately, 3 hours, 24 hours, 7 or 28 days after angiography, and the kidneys were histologically investigated. In several cases the angiograms showed small alterations (transitory vasospasm, inhomogeneous spots on the nephrogram). Histology revealed in the initial period a homogeneous, pinkish, protein-like substance in the Bowman capsule and in the lumen of the tubuli, whereas later infiltrations by round cells and local accumulation of connective tissues were found. (L.E.)

  16. Today and tomorrow of intravenous coronary angiography programme in Japan

    International Nuclear Information System (INIS)

    Ando, Masami; Hyodo, Kazuyuki

    1994-01-01

    Development of an intravenous coronary angiography system using monochromated synchrotron radiation at the Photon Factory is described. This comprises an asymmetric cut silicon monochromator crystal to get a larger exposure area, a two dimensional imaging system using an imaging intensifier coupled to a CCD TV camera and a fast video data acquisition system. The whole system is under development using alive dogs. A future system including a dedicated insertion device applicable to alive humans is also proposed. (author)

  17. National Synchrotron Light Source angiography personnel protection interlock

    International Nuclear Information System (INIS)

    Gmuer, N.; Larson, R.; Thomlinson, W.

    1992-06-01

    This document has been written to describe the safety system operation at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). The angiography exposure process involves scanning a patient up and down through dual fixed-position x-ray beams; exposure is controlled by opening and closing a fast-acting Safety Shutter mechanism at precise times in relation to the up and down motion of the scan chair. The fast-acting Safety Shutter mechanism is the primary radiation-stopping element protecting the patient while the chair is at rest and while it is reversing directions during the scan. Its fail-safe and fast operation is essential for the safety of the patient. Operation of X17B2 as a human subject angiography station necessitates the implementation of a personnel protection interlock system that, in conjunction with the Safety Shutters: permits safe access to the patient exposure area while the synchrotron radiation beam is illuminating the upstream dual energy monochromator; allows a patient to be imaged by the monochromatized beam under the supervision of a Responsible Physician, with scan chair motion and precision shutter actuation regulated by an angiography control computer, while providing a suitable number of safeguards against accidental radiation exposure; has different modes of operation to accommodate equipment set-up, test, and calibration; and patient exposure; and ensures the quick extinction of the beam if a potentially unsafe condition is detected. The interlock system which performs these safety functions is called the Angiography Personnel Protection Interlock (APPI). The APPI Document is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system

  18. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  19. Occurence of stationary waves in angiography of peripheral vessels

    International Nuclear Information System (INIS)

    Boettcher, H.D.; Schmilowski, G.M.; Haverkamp, U.; Wagner, W.

    1983-01-01

    Among 229 angiographies of periphal vascular occlusions performed in 1981 and during the first half of 1982 at the Radiologic Clinic of Muenster University, stationary waves developed in one case in the vascular band before the occlusion. This phenomenon can be a pointer towards assuming that over long distances before the occlusion there is no satisfactory outflow provided for by collaterals, intact arterio-arterial or arterio-venous connections. (orig.) [de

  20. National Synchrotron Light Source angiography personnel protection interlock

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.; Larson, R.; Thomlinson, W.

    1992-06-01

    This document has been written to describe the safety system operation at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). The angiography exposure process involves scanning a patient up and down through dual fixed-position x-ray beams; exposure is controlled by opening and closing a fast-acting Safety Shutter mechanism at precise times in relation to the up and down motion of the scan chair. The fast-acting Safety Shutter mechanism is the primary radiation-stopping element protecting the patient while the chair is at rest and while it is reversing directions during the scan. Its fail-safe and fast operation is essential for the safety of the patient. Operation of X17B2 as a human subject angiography station necessitates the implementation of a personnel protection interlock system that, in conjunction with the Safety Shutters: permits safe access to the patient exposure area while the synchrotron radiation beam is illuminating the upstream dual energy monochromator; allows a patient to be imaged by the monochromatized beam under the supervision of a Responsible Physician, with scan chair motion and precision shutter actuation regulated by an angiography control computer, while providing a suitable number of safeguards against accidental radiation exposure; has different modes of operation to accommodate equipment set-up, test, and calibration; and patient exposure; and ensures the quick extinction of the beam if a potentially unsafe condition is detected. The interlock system which performs these safety functions is called the Angiography Personnel Protection Interlock (APPI). The APPI Document is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system.