WorldWideScience

Sample records for fluids case study

  1. STUDY OF 200 CASES OF PLEURAL FLUID

    Directory of Open Access Journals (Sweden)

    Ramakrishna R

    2016-09-01

    Full Text Available BACKGROUND We have studied 200 patients of pleural fluid presenting to our tertiary care centre. Presence of cases of pleural fluid is a common presentation both in pulmonary and extrapulmonary diseases. We analysed the patients having both exudates and transudates and studied the results. MATERIALS AND METHODS We selected patients above 20 years of age and classified the patients with pleural fluid as having transudates and exudates. We studied the causes of transudates and exudates. A total of 200 patients are studied in this prospective study. Diagnosis of pleural exudates is made on the basis of Light’s criteria, chest x-ray, pleural fluid analysis, CT scan in selected patients, sputum examination, bronchoscopy and bronchial washings. Moribund and non-cooperative patients and HIV positives were excluded from the study. RESULTS Among the 200 patients, 91% have exudates. 9% have transudates by Light’s criteria. Tuberculosis is the commonest cause of effusions (64.83% followed by malignancy (13.73% and sympneumonic or parapneumonic effusions (9.89%. Pleural effusions occurred predominantly in males. Prevalence of diabetes Mellitus among cases of tuberculous pleural effusions is 13.56%. Tuberculous effusions are predominantly right-sided. CONCLUSION Predominant cases of pleural fluid are exudates. Commonest cause of pleural effusion is Tuberculosis followed by malignancy both pulmonary and extrapulmonary and sym. and parapneumonic effusions. Prevalence of Diabetes among Tuberculous pleural effusion cases is more or less same as in general population. Cough, expectoration fever, chest pain and breathlessness are the common symptoms occurring in three fourths of the patients of tuberculous pleural effusion. Most of the cases of Tuberculous effusion are above 30 years of age. In the diagnosis of tuberculous pleural effusion, Pleural fluid ADA is very important. Pleural fluid cytology, pleural biopsy, bronchoscopy, bronchial washings and sputum

  2. Three-dimensional fluid-structure interaction case study on cubical fluid cavity with flexible bottom

    Science.gov (United States)

    Ghelardi, Stefano; Rizzo, Cesare; Villa, Diego

    2017-12-01

    In this paper, we report our study on a numerical fluid-structure interaction problem originally presented by Mok et al. (2001) in two dimensions and later studied in three dimensions by Valdés Vazquez (2007), Lombardi (2012), and Trimarchi (2012). We focus on a 3D test case in which we evaluated the sensitivity of several input parameters on the fluid and structural results. In particular, this analysis provides a starting point from which we can look deeper into specific aspects of these simulations and analyze more realistic cases, e.g., in sails design. In this study, using the commercial software ADINA™, we addressed a well-known unsteadiness problem comprising a square box representing the fluid domain with a flexible bottom modeled with structural shell elements. We compared data from previously published work whose authors used the same numerical approach, i.e., a partitioned approach coupling a finite volume solver (for the fluid domain) and a finite element solver (for the solid domain). Specifically, we established several benchmarks and made comparisons with respect to fluid and solid meshes, structural element types, and structural damping, as well as solution algorithms. Moreover, we compared our method with a monolithic finite element solution method. Our comparisons of new and old results provide an outline of best practices for such simulations.

  3. K-11 students’ creative thinking ability on static fluid: a case study

    Science.gov (United States)

    Hanni, I. U.; Muslim; Hasanah, L.; Samsudin, A.

    2018-05-01

    Creative thinking is one of the fundamental components of 21st-century education that needs to be possessed and developed in students. Thus, the students have the ability to find many alternative solutions to solve problems in physics learning. The study aimed at providing the students’ creative thinking ability on Static Fluid. A case study has been implemented through a single case, namely embedded design. Participants in this study are 27 K-11 students. The instrument utilized is Test for Creative Thinking-Static Fluid (TCT-SF) which has been validated by the experts. The result shows that 10.74 (approximately 35.8%) of the maximum scores. In conclusion, students’ creative thinking ability on Static Fluid is still stumpy, hence, it is needed to develop creative thinking ability in K-11 students’ context.

  4. Scaffolding for solving problem in static fluid: A case study

    Science.gov (United States)

    Koes-H, Supriyono; Muhardjito, Wijaya, Charisma P.

    2018-01-01

    Problem solving is one of the basic abilities that should be developed from learning physics. However, students still face difficulties in the process of non-routine problem-solving. Efforts are necessary to be taken in order to identify such difficulties and the solutions to solve them. An effort in the form of a diagnosis of students' performance in problem solving can be taken to identify their difficulties, and various instructional scaffolding supports can be utilized to eliminate the difficulties. This case study aimed to describe the students' difficulties in solving static fluid problems and the effort to overcome such difficulties through different scaffolding supports. The research subjects consisted of four 10-grade students of (Public Senior High School) SMAN 4 Malang selected by purposive sampling technique. The data of students' difficulties were collected via think-aloud protocol implemented on students' performance in solving non-routine static fluid problems. Subsequently, combined scaffolding supports were given to the students based on their particular difficulties. The research findings pointed out that there were several conceptual difficulties discovered from the students when solving static fluid problems, i.e. the use of buoyancy force formula, determination of all forces acting on a plane in a fluid, the resultant force on a plane in a fluid, and determination of a plane depth in a fluid. An effort that can be taken to overcome such conceptual difficulties is providing a combination of some appropriate scaffolding supports, namely question prompts with specific domains, simulation, and parallel modeling. The combination can solve students' lack of knowledge and improve their conceptual understanding, as well as help them to find solutions by linking the problems with their prior knowledge. According to the findings, teachers are suggested to diagnose the students' difficulties so that they can provide an appropriate combination of

  5. The diagnostic role of cervico-vaginal fluid interleukins-1α in endometriosis: A case-control study

    Directory of Open Access Journals (Sweden)

    Farahnaz Mardanian

    2014-01-01

    Full Text Available Background: Endometriosis is a chronic and progressive gynecological disorder and is manifest by dysmenorrhea and a major cause of infertility and chronic pelvic pain. The study was designed to compare the value of cervico-vaginal fluid of interleukin-1α (IL-1α in patients with and without endometriosis. Materials and Methods: Fifty women were assessed in this case control study. The case group included 25 patients with endometriosis. The control group included 25 women without any evidence of endometriosis or any other genital disease. Endometriosis was confirmed by laparoscopy and histopathological examination. Cervico-vaginal fluid samples were obtained from patients during the follicular phase and preup surgery to assess the levels of IL-1α in cervico-vaginal fluid. The level of IL-1α was assessed using commercially available Avi Bionhuman Enzyme-Linked Immunosorbent Assay kits (FIN-01720, Vantaa, Finland for IL-1α. Receiver-operator curve analysis was used to estimate the power of IL-1α to distinguish subjects with endometriosis from controls. Results: The cervico-vaginal fluid level of IL-1α in cases was 210.44 ± 40.11 pg/mL and in controls was 54.28 ± 25.73 pg/mL, the differences between two groups was statistically significant (P < 0.0001. The cut-off point for cervico-vaginal fluid IL-1 for endometriosis was 105 pg/mL, with a sensitivity of 100% (95% confidence interval [CI]: 86.2-100, and specificity of 100% (95% CI: 86.2-100. Conclusion: Results show a significant increase in the cervico-vaginal fluid levels of IL-1α, in women with endometriosis, that it can be a useful marker in the diagnosis of endometriosis.

  6. The diagnostic role of cervico-vaginal fluid interleukins-1α in endometriosis: A case-control study

    OpenAIRE

    Farahnaz Mardanian; Zahra Sheikh-Soleimani

    2014-01-01

    Background: Endometriosis is a chronic and progressive gynecological disorder and is manifest by dysmenorrhea and a major cause of infertility and chronic pelvic pain. The study was designed to compare the value of cervico-vaginal fluid of interleukin-1? (IL-1?) in patients with and without endometriosis. Materials and Methods: Fifty women were assessed in this case control study. The case group included 25 patients with endometriosis. The control group included 25 women without any evidence ...

  7. CT study in primary low spinal fluid pressure syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Moritoshi; Okayama, Kenji; Kubo, Hiromasa; Watanabe, Hiromi; Endou, Riuko (Ohmiya Red Cross Hospital, Yono, Saitama (Japan))

    1991-02-01

    CT findings in primary low spinal fluid pressure syndrome were studied on the basis of 3 cases. Case 1 was a 43-year-old male with a complicated bilateral isodense subdural hematoma (SDH). Case 2 was a 45-year-old female with a complicated bilateral high dense SDH. Case 3 was a 36-year-old female discharged without any complications after spinal fluid pressure normalized. Slight downward displacement of the brain under low spinal fluid pressure was shown as the narrowing of a Sylvian fissures and infratentorial cisterns on CT. On the other hand, in this syndrome with a complicated bilateral isodense SDH, in addition to this finding, CT revealed distortion and narrowing of body lateral ventricles, which might be differential findings from this syndrome without complicated SDH. Under low spinal fluid pressure, bridging veins are more stretched by a downward displacement of the brain. And consequently they were easily injured and SDH was developed. (author).

  8. Fluid management of hypernatraemic dehydration to prevent cerebral oedema: a retrospective case control study of 97 children in China.

    Science.gov (United States)

    Fang, Chengqing; Mao, Jianhua; Dai, Yuwen; Xia, Yonghui; Fu, Haidong; Chen, Yifang; Wang, Yaping; Liu, Aimin

    2010-06-01

    To compare the fluid management of hypernatraemic dehydration in acute gastroenteritis in those who developed cerebral oedema (cases) versus those who did not (controls). A retrospective study of 97 cases of hypernatraemic dehydration at a tertiary children's hospital in China over five years, in which rehydration regimes of 49 children who developed cerebral oedema were compared with 48 children who made an uneventful recovery. Risk factors for cerebral oedema (vs. no cerebral oedema) were an initial fluid bolus (29/49 vs. 15/48, P=0.006), the mean rate of bolus infusion (14.7+/-2.2 vs. 10.8+/-1.4 mL/kg/hr, Pdehydration were too rapid a rate of rehydration, an initial fluid bolus to rapidly expand plasma volume and the severity of the hypernatraemia. Thus, we conclude that a uniformly slow rate of rehydration is the best way of preventing cerebral oedema.

  9. Method for monitoring fluid movement behind casing in oil and gas wells

    International Nuclear Information System (INIS)

    Fertl, W.H.

    1981-01-01

    A new method was developed for locating fluid movement between the casing and the earth formations in a cased earth borehole. It comprises traversing a cased earth borehole with a gamma ray detector, thereby creating a base log; injecting a fluid containing a salt of potassium, thorium or uranium into the formation; and creating a second log indicative of the movement of the injected fluid. (D.N.)

  10. Global dynamics of shaft lines of turbo-machineries coupled to surrounding fluids: application to the case of fluid sheets; Dynamique globale des lignes d'arbres de turbomachines couplees aux fluides environnants: application au cas des lames fluides

    Energy Technology Data Exchange (ETDEWEB)

    Lornage, D.

    2001-12-15

    Shaft lines of turbo-machineries have to stand increasing reliability, efficiency and safety requirements. A precise modeling of the rotating parts with all possible coupling has become necessary. In this context, this work aims to develop a global modeling of rotating wheel/shaft system inside a surrounding fluid in order to foresee its dynamical behaviour. The use and advantage of Eulerian, Lagrangian and mixed (arbitrary Lagrangian Eulerian - ALE) formulations is recalled first. A bibliographic synthesis of the classical techniques used in structure mechanics and of coupling techniques for rotating machines is presented. The coupling technique retained is presented. It uses fluid and structure models independently developed and validated. The structure domain is discretized by the finite-element method. The fluid domain is discretized by the finite-difference method taking into consideration the hypotheses linked with thin films. A modal base projection combined with a mesh at the fluid-structure interface allows an efficient, adaptable and evolutive coupling. Finally, the method is applied to 3 test-cases. The first two ones comprise a shaft/disc system coupled to a fluid sheet between the disc and the casing and to an hydrodynamic bearing. Both cases allow a first validation of the coupling method. The third case aims to study a structure closer to a real system made of a shaft and a wheel coupled to a fluid sheet between a flange and a casing. These three applications allow to show the trends linked with the fluid effects and the coupling between the flexible sub-parts of the structure. (J.S.)

  11. MR imaging of a malignant schwannoma and an osteoblastoma with fluid-fluid levels. Report of two new cases

    International Nuclear Information System (INIS)

    Vilanova, J.C.; Dolz, J.L.; Aldoma, J.; Capdevila, A.; Maestro de Leon, J.L.; Aparicio, A.

    1998-01-01

    One case of malignant schwannoma of the sacrum and another of occipital osteoblastoma were evaluated by MR imaging. Both tumors showed fluid-fluid levels with different signal intensities in the sequences performed. Pathologic examination revealed hemmorhagic fluid in both tumors. Malignant schwannoma and osteoblastoma should be included in the list of bone and soft-tissue with fluid-fluid levels. Our data confirm the non-specificity of this finding, which only suggests the presence of previous intratumoral hemorrhage. (orig.) (orig.)

  12. MR imaging of a malignant schwannoma and an osteoblastoma with fluid-fluid levels. Report of two new cases

    Energy Technology Data Exchange (ETDEWEB)

    Vilanova, J.C.; Dolz, J.L.; Aldoma, J.; Capdevila, A. [Centre Diagnostic Pedralbes, Ressonancia Magnetica, Barcelona (Spain); Maestro de Leon, J.L.; Aparicio, A. [Department of Neurosurgery, Hospital Mutua de Terrassa, Barcelona (Spain)

    1998-10-01

    One case of malignant schwannoma of the sacrum and another of occipital osteoblastoma were evaluated by MR imaging. Both tumors showed fluid-fluid levels with different signal intensities in the sequences performed. Pathologic examination revealed hemmorhagic fluid in both tumors. Malignant schwannoma and osteoblastoma should be included in the list of bone and soft-tissue with fluid-fluid levels. Our data confirm the non-specificity of this finding, which only suggests the presence of previous intratumoral hemorrhage. (orig.) (orig.) With 2 figs., 2 tabs., 17 refs.

  13. Mortality studies of metalworking fluid exposure in the automobile industry: VI. A case-control study of esophageal cancer.

    Science.gov (United States)

    Sullivan, P A; Eisen, E A; Woskie, S R; Kriebel, D; Wegman, D H; Hallock, M F; Hammond, S K; Tolbert, P E; Smith, T J; Monson, R R

    1998-07-01

    Results are reported from a nested case-control study of 60 esophageal cancer deaths among 46,384 automobile manufacturing workers potentially exposed to metalworking fluids (MWF) in machining and grinding operations. By using incidence-density sampling, controls were selected with a sampling ratio of 20:1 from among co-workers who remained at risk by the age of death of the case, matched on race, gender, plant, and year of birth. Conditional logistic regression was used to evaluate the risk associated with cumulative exposure (mg/m3-years) to each of three types of metalworking fluid (straight, soluble, and synthetic MWF), as well as with years of exposure to selected components of MWF, including nitrosamines, sulfur, biocides, and several metals. Esophageal cancer was found to be significantly associated with exposure to both soluble and synthetic MWF in grinding operations. The odds ratios (ORs) for grinding with soluble MWF were elevated at 2.5 or greater in all categories of cumulative exposure, although the exposure-response trend was statistically significant only when exposure was measured as duration. Those with 12 or more years exposure to soluble MWF in grinding operations experienced a 9.3-fold relative risk of esophageal cancer mortality (95% CI = 2.1-42.1). The OR for ever grinding with synthetic MWF was 4.1 (95% CI = 1.1-15.0). Elevated risk was also associated with two agents found in both synthetic and soluble fluids, nitrosamines, and biocides. For exposure to nitrosamines, the OR was 5.4 (95% CI = 1.5-19.9); for biocides the OR was 3.8 (95% CI = 0.8-18.9). However, because the same workers were exposed to grinding with synthetics, nitrosamines and biocides, it was not possible to separate the specific risks associated with these components.

  14. Aggressive Fluid Resuscitation in Severe Pediatric Hyperglycemic Hyperosmolar Syndrome: A Case Report

    Directory of Open Access Journals (Sweden)

    Sharara-Chami Rana

    2010-03-01

    Full Text Available Objective. This report describes a severe case of hyperglycemic hyperosmolar syndrome complicated by rhabdomyolysis, acute kidney injury, hyperthermia, and hypovolemic shock, with management centred upon fluid administration. Design. Case report. Setting. Pediatric intensive care unit in university teaching hospital. Patients. 12 years old adolescent female presenting with hyperglycemic hyperosmolar syndrome with a new diagnosis of type 2 diabetes mellitus. Intervention. Aggressive fluid resuscitation and insulin. Main results. The patient had a good outcome, discharged home on hospital day 6. Conclusions. Hyperglycemic hyperosmolar syndrome is associated with a number of complications. Management strategies are undefined, given the rarity of its presentation, and further studies are warranted.

  15. Resolution of through tubing fluid flow and behind casing fluid flow in multiple completion wells

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1977-01-01

    A method is provided for resolving undesired fluid flow in cement channels behind casing in one producing zone of a multi zone completion well operating on gas lift from the fluid flow from lower producing zones in the same well which is contained in production tubing passing through the producing zone being investigated. Gamma rays which are characteristic of the decay of the unstable isotope nitrogen 16 produced by activation of elemental oxygen nuclei comprising the molecular structure of both the tubing fluid flow and the undesired fluid flow are detected in at least two energy bonds at two longitudinally spaced detectors in a well borehole. By appropriately combining the four count rate signals so producing according to predetermined relationships the two fluid flow components in the same direction may be uniquely distinguished on the basis of their differing distances from the gamma ray detectors. 9 claims, 17 figures

  16. Intrapituitary fluid levels following haemorrhage: MRI appearances in 13 cases

    International Nuclear Information System (INIS)

    Lenthall, R.K.; Dean, J.R.; Jeffree, M.A.; Bartlett, J.R.

    1999-01-01

    Demonstration of fluid levels on MRI is well recognised in cerebral haematomas, tumours and cysts. The occurrence of fluid levels within haemorrhagic pituitary tumours has not previously been described in detail. Evidence of haemorrhage was identified in 27 of 125 pituitary tumours. Fluid levels occurred in 13 of these haemorrhagic tumours. No association with histological type was identified. Recognised risk factors for haemorrhage were identified in half of the cases. (orig.) (orig.)

  17. Prevalence, extension and characteristics of fluid-fluid levels in bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Venstermans, C.; Gielen, J.; Parizel, P.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, F.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); AZ St-Maarten, Department of Radiology, Duffel/Mechelen (Belgium); Vogel, J. [Leiden University Medical Centre, Department of Orthopedics, Leiden (Netherlands); Kroon, H.M.; Bloem, J.L. [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Schepper, A.M.A. de [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands)

    2006-12-15

    The purpose of this study was to determine the prevalence, extension and signal characteristics of fluid-fluid levels in a large series of 700 bone and 700 soft tissue tumors. Out of a multi-institutional database, MRI of 700 consecutive patients with a bone tumor and MRI of 700 consecutive patients with a soft tissue neoplasm were retrospectively reviewed for the presence of fluid-fluid levels. Extension (single, multiple and proportion of the lesion occupied by fluid-fluid levels) and signal characteristics on magnetic resonance imaging of fluid-fluid levels were determined. In all patients, pathologic correlation was available. Of 700 patients with a bone tumor, 19 (10 male and 9 female; mean age, 29 years) presented with a fluid-fluid level (prevalence 2.7%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included aneurysmal bone cyst (ten cases), fibrous dysplasia (two cases), osteoblastoma (one case), simple bone cyst (one case), telangiectatic osteosarcoma (one case), ''brown tumor'' (one case), chondroblastoma (one case) and giant cell tumor (two cases). Of 700 patients with a soft tissue tumor, 20 (9 males and 11 females; mean age, 34 years) presented with a fluid-fluid level (prevalence 2.9%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included cavernous hemangioma (12 cases), synovial sarcoma (3 cases), angiosarcoma (1 case), aneurysmal bone cyst of soft tissue (1 case), myxofibrosarcoma (1 case) and high-grade sarcoma ''not otherwise specified'' (2 cases). In our series, the largest reported in the literature to the best of our knowledge, the presence of fluid-fluid levels is a rare finding with a prevalence of 2.7 and 2.9% in bone and soft tissue tumors, respectively. Fluid-fluid levels remain a non-specific finding and can

  18. Cerebrospinal fluid cutaneous fistula following obstetric epidural analgaesia. Case report.

    Science.gov (United States)

    Fedriani de Matos, J J; Quintero Salvago, A V; Gómez Cortés, M D

    2017-10-01

    Cutaneous fistula of cerebrospinal fluid is a rare complication of neuroaxial blockade. We report the case of a parturient in whom an epidural catheter was placed for labour analgesia and 12h after the catheter was removed, presented an abundant asymptomatic fluid leak from the puncture site, compatible in the cyto-chemical analysis with cerebrospinal fluid. She was treated with acetazolamide, compression of skin orifice of the fluid leakage, antibiotic prophylaxis, hydration and rest, and progressed satisfactorily without requiring blood patch. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. First sternocostal degenerative arthritis with intrarticular fluid collection. A case report.

    Science.gov (United States)

    Chalazonitis, Athanasios N; Condilis, Nicolas; Tilentzoglou, Anastasia C; Pontikis, John; Tzovara, Joannie

    2006-01-01

    A rare case with clinical condition of first sternocostal degenerative arthritis with intra-articular fluid collection that developed after long-lasting intense exercise (weight-lifting) for twenty years is reported. Imaging findings and differential diagnoses of the case are presented.

  20. Numerical Modeling of Fluid-Structure Interaction with Rheologically Complex Fluids

    OpenAIRE

    Chen, Xingyuan

    2014-01-01

    In the present work the interaction between rheologically complex fluids and elastic solids is studied by means of numerical modeling. The investigated complex fluids are non-Newtonian viscoelastic fluids. The fluid-structure interaction (FSI) of this kind is frequently encountered in injection molding, food processing, pharmaceutical engineering and biomedicine. The investigation via experiments is costly, difficult or in some cases, even impossible. Therefore, research is increasingly aided...

  1. ROLE OF AMNIOINFUSION ON NEONATAL OUTCOME IN CASES WITH MECONIUMSTAINED AMNIOTIC FLUID

    Directory of Open Access Journals (Sweden)

    K. Chandramathy

    2016-10-01

    Full Text Available BACKGROUND Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration in newborn. AIM The effect of amnioinfusion in meconium-stained amniotic fluid in reducing the incidence of meconium aspiration syndrome, hypoxic ischaemic encephalopathy and perinatal mortality in newborn. MATERIALS AND METHODS The study was carried out in the Departments of Obstetrics and Gynaecology and NICU at Government Medical College, Kozhikode, in a time duration of one year from January 2014 to December 2014. This is a prospective case control study. We have studied 210 antenatal women admitted to the labour room with grade 2/3 meconium-stained amniotic fluid after 36 weeks of gestation. Amnioinfusion was given in 140 cases and 70 cases given standard care. Patients were monitored with electronic foetal heart monitoring and caesarean section was done in case of foetal distress or those who are in early labour. There was no significant difference between study group and control group according to age, parity, gestational age, presence of complications like hypertension/pre-eclampsia, post-dated pregnancy, anaemia, etc. RESULTS Foetal heart rate decelerations occurred in 27 out of 140 cases (19% in the study group and 23 out of 70 (33% in control group (P <0.05. NEONATAL OUTCOME In our study those who received amnioinfusion, only 19% delivered babies with APGAR <9 at 1’ while those who do not received, 36% delivered babies with APGAR <9 at 1’ (P value of 0.009. Meconium aspiration syndrome occurred in 2.1% of cases in the infusion group and 11.4% in the non-infusion group (P<0.005. Respiratory distress was markedly reduced in amnioinfusion group 28% compared to 63% in controls (P=0.002. NICU admissions were 64% in control group compared to 22% in amnioinfusion group. Perinatal mortality and hypoxic ischaemic encephalopathy in the infusion group were nil as compared to 7% and 11% in the control group

  2. Nonpancreatic pseudocyst with fat-fluid level: a case report

    International Nuclear Information System (INIS)

    La, Youn Jong; Choi, Gyo Chang; Koh, Eun Suk

    2000-01-01

    Nonpancreatic pseudocyst is a rare lesion, with a specific fat-fluid level in the cyst. It is found among all age groups. The condition has been previously reported in foreign but not in domestic journals; we now describe one such case. (author)

  3. Cognitive Behavioral Treatment to Improve Adherence to Hemodialysis Fluid Restrictions: A Case Report

    Directory of Open Access Journals (Sweden)

    Heather M. Anson

    2009-01-01

    Full Text Available This case report describes outpatient psychological treatment targeting adherence to fluid restrictions in a hemodialysis patient. The consequences of nonadherence to fluid restrictions in hemodialysis patients range from minor discomfort to increased hospitalizations and mortality rates. In addition, when patients chronically fail to adhere, they may no longer be candidates for kidney transplant. The interventions focused on polydipsia, characterized by excessive fluid intake. The methods involved 11-sessions of individual psychotherapy incorporating strategies including increasing awareness, decreasing motivation, increasing effort, engaging in competing events, conducting thought stopping, breaking repetitive routines, eliciting social support, and receiving reinforcement. Results demonstrated that the patient successfully restricted his fluid intake at or below recommended levels 83% of days after fading of treatment began. This case report demonstrates the success of cognitive behavioral treatment strategies with a nonpsychiatric hemodialysis patient.

  4. [External lumbar drainage with volumetric continuing infusion pump in patients with cerebrospinal fluid leak. A case series].

    Science.gov (United States)

    Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén

    To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  5. Cognitive Behavioral Treatment to Improve Adherence to Hemodialysis Fluid Restrictions: A Case Report

    OpenAIRE

    Anson, Heather M.; Byrd, Michelle R.; Koch, Ellen I.

    2009-01-01

    This case report describes outpatient psychological treatment targeting adherence to fluid restrictions in a hemodialysis patient. The consequences of nonadherence to fluid restrictions in hemodialysis patients range from minor discomfort to increased hospitalizations and mortality rates. In addition, when patients chronically fail to adhere, they may no longer be candidates for kidney transplant. The interventions focused on polydipsia, characterized by excessive fluid intake. The methods in...

  6. Cerebrospinal fluid ascites. a case report and literature review ...

    African Journals Online (AJOL)

    Cerebrospinal fluid ascites is one complication of ventriculoperitoneal shunt surgery. This case reports a 7year old child with abdominal distention five years after ventriculoperitoneal shunt insertion for hydrocephalus secondary to aqueductal stenosis. The child had a history of multiple shunt revisions. Liver, cardiac and ...

  7. Modern fluid dynamics

    CERN Document Server

    Kleinstreuer, Clement

    2018-01-01

    Modern Fluid Dynamics, Second Edition provides up-to-date coverage of intermediate and advanced fluids topics. The text emphasizes fundamentals and applications, supported by worked examples and case studies. Scale analysis, non-Newtonian fluid flow, surface coating, convection heat transfer, lubrication, fluid-particle dynamics, microfluidics, entropy generation, and fluid-structure interactions are among the topics covered. Part A presents fluids principles, and prepares readers for the applications of fluid dynamics covered in Part B, which includes computer simulations and project writing. A review of the engineering math needed for fluid dynamics is included in an appendix.

  8. Radiation inactivation of animal viruses in culture fluid and sewage; a case study

    International Nuclear Information System (INIS)

    Groneman, A.F.; Frenkel, S.; Terpstra, C.

    1977-01-01

    Inactivation studies of different animal viruses were performed with gamma irradiation from a 60 Co-source to evaluate the technical and economic feasibility of sterilization of sewage of a veterinary institute involved in research on virus diseases and the production of virus vaccines. The D 10 values for swine fever virus, foot-and-mouth disease virus (FMDV) and swine vesicular disease virus (SVDV) irradiated in culture medium at 0degC were 1.8, 4.5, and 5.9 kGy (0.18, 0.45, and 0.59 Mrad), respectively. Suspensions of SVDV and FMDV were mixed with raw sludge and irradiated at 8degC. Raw sludge had a protecting effect on FMDV, if compared to culture fluid, increasing the D 10 value significantly to 6.5 kGy (0.65 Mrad). No similar protective effect was observed in the case of SVDV. Addition of 0.2 M NaBr did not significantly increase the radiosensitivity of these two viruses. The technical and economic feasibility for sterilization of sewage and sludge by 60 Co-gamma irradiation are discussed

  9. A study on the CHF enhancement of pool boiling using nano-fluids

    International Nuclear Information System (INIS)

    Chang, Won Joon

    2009-02-01

    The understanding of CHF phenomenon and an accurate prediction of the CHF condition are important for safe and economic design of many heat transfer units including nuclear reactors, fossil fuel boilers, fusion reactors, electronic chips, etc. The phenomenon has been investigated extensively over the world since Nukiyama (1934) first characterized it. In particular, a large amount of significant work has been done during the last four decades with the development of water cooled nuclear reactors. The wettability of the heated surface under pool boiling of surfactant solutions and nano-fluids has been investigated. Tri-sodium phosphate (TSP, Na 3 PO 4 ) solutions and Aluminum oxide nano-fluids were prepared for experiments. Contact angles of pure water and the solutions on the quenched surface and fresh surface were measured. Surfaces deposited TSP and nano-particle could affect surface energy of the strips and enhance hydrophilicity of the surfaces. Several implications of the experimental results on the pool boiling CHF model and CHF enhancement using TSP and NF were discussed. A increase of CHF was observed with nano-fluid. The addition of nano-particle helped to increase the wettability by reducing the surface tension. This happens with the decrease in bubble diameter, breakup of bubbles and avoidance of bubble coalescence. CHF increase or decrease depends upon competition between high wettability and high instability. An optimum nano-fluid concentration is needed which must have high crystalline content. When the concentration reaches at a critical value, CHF will tend to a constant value. As the results of previous study, surface tension effect the results of CHF. And it is same to nano-fluids, because surface tension change the dynamics of mixture fluids at two phase and means the instability of thermal hydraulics. Contact angle which be in the limelight at recent research means wettability of heated surface. However, in case of nano-fluids, both are

  10. Magnetic fluid axisymmetric volume on a horizontal plane near a vertical line conductor in case of non-wetting

    Energy Technology Data Exchange (ETDEWEB)

    Vinogradova, A.S., E-mail: vinogradova.msu@gmail.com; Turkov, V.A.; Naletova, V.A.

    2017-06-01

    Static shapes of a magnetic fluid axisymmetric volume on a horizontal plane in the magnetic field of a vertical line conductor are studied theoretically in case of non-wetting while the current is slowly changing in a quasi-static manner. The possibility of the fluid shape hysteresis for a cyclic increase and decrease of the current and of spasmodic changes at certain values of the current is investigated. - Highlights: • Magnetic fluid on a horizontal plane near a line conductor is studied theoretically. • For fixed current and volume various static shapes are obtained. • Spasmodic and hysteresis phenomena are found.

  11. Modelling and simulation of compressible fluid flow in oil reservoir: a case study of the Jubilee Field, Tano Basin (Ghana)

    International Nuclear Information System (INIS)

    Gawusu, S.

    2015-07-01

    Oil extraction represents an important investment and the control of a rational exploitation of a field means mastering various scientific techniques including the understanding of the dynamics of fluids in place. This thesis presents a theoretical investigation of the dynamic behaviour of an oil reservoir during its exploitation. The study investigated the dynamics of fluid flow patterns in a homogeneous oil reservoir using the Radial Diffusivity Equation (RDE) as well as two phase oil-water flow equations. The RDE model was solved analytically and numerically for pressure using the Constant Terminal Rate Solution (CTRS) and the fully implicit Finite Difference Method (FDM) respectively. The mathematical derivations of the models and their solution procedures were presented to allow for easy utilization of the techniques for reservoir and engineering applications. The study predicted that the initial oil reservoir pressure will be able to do the extraction for a very long time before any other recovery method will be used to aid in the extraction process depending on the rate of production. Reservoir simulation describing a one dimensional radial flow of a compressible fluid in porous media may be adequately performed using ordinary laptop computers as revealed by the study. For the simulation of MATLAB, the case of the Jubilee Fields, Tano Basin was studied, an algorithm was developed for the simulation of pressure in the reservoir. It ensues from the analysis of the plots of pressure vrs time and space that the Pressure Transient Analysis (PTA) was duly followed. The approximate solutions of the analytical and numerical solutions to the Radial Diffusivity Equation (RDE) were in excellent agreement, thus the reservoir simulation model developed can be used to describe typical pressure-time relationships that are used in conventional Pressure Transient Analysis (PTA). The study was extended to two phase oil-water flow in reservoirs. The flow of fluids in multi

  12. STUDY OF BIOCHEMICAL PARAMETERS IN AMNIOTIC FLUID FOR ASSESSMENT OF FOETAL MATURITY IN CASES OF NORMAL PREGNANCY

    Directory of Open Access Journals (Sweden)

    Leela

    2015-11-01

    Full Text Available Assessment of foetal maturity had been proven of value in evaluating the foetal condition. Accurate assessment of foetal maturity is essential for the proper timing of delivery in various risk pregnancies. Amniotic Fluid analysis for foetal maturity had been of proven value. In the present study, study of biochemical parameters in amniotic fluid in respect of Creatinine, Uric Acid, Urea, Total Proteins, and Electrolytes i.e. Sodium, Potassium and Chloride has been done, along with Serum Electrolytes. Standard methodologies were adopted. The observations in the present study correlated with the works of Chadick et al and Pitkin and Zwirek. The levels of Creatinine, Uric Acid and Urea in Amniotic Fluid showed elevation, while Total Proteins and Serum Sodium showed a decline, as gestation progressed. The Serum and Amniotic Fluid Potassium and Chloride levels remain almost constant throughout the pregnancy. Thus, it is observed that the use of multiple parameters is desirable for accurate assessment of foetal maturity.

  13. Studies of complexity in fluid systems

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, Sidney R.

    2000-06-12

    This is the final report of Grant DE-FG02-92ER25119, ''Studies of Complexity in Fluids'', we have investigated turbulence, flow in granular materials, singularities in evolution of fluid surfaces and selective withdrawal fluid flows. We have studied numerical methods for dealing with complex phenomena, and done simulations on the formation of river networks. We have also studied contact-line deposition that occurs in a drying drop.

  14. Delayed sub-aponeurotic fluid collections in infancy: Three cases and a review of the literature

    OpenAIRE

    Petraglia, Anthony L.; Moravan, Michael J.; Marky, Andrew H.; Silberstein, Howard J.

    2010-01-01

    Background: Sub-aponeurotic fluid collections (SFCs) in the neonatal period are poorly described in the literature. We describe the occurrence, possible etiologies and treatment of sub-aponeurotic fluid collections following the neonatal period. Case Description: We present 3 cases of previously healthy children who developed soft, fluctuant, extracranial masses several weeks after birth. All 3 children were seen by a pediatric neurosurgeon after parents noticed scalp masses between 5 and 9 w...

  15. Spinning fluids in general relativity

    Science.gov (United States)

    Ray, J. R.; Smalley, L. L.

    1982-01-01

    General relativity field equations are employed to examine a continuous medium with internal spin. A variational principle formerly applied in the special relativity case is extended to the general relativity case, using a tetrad to express the spin density and the four-velocity of the fluid. An energy-momentum tensor is subsequently defined for a spinning fluid. The equations of motion of the fluid are suggested to be useful in analytical studies of galaxies, for anisotropic Bianchi universes, and for turbulent eddies.

  16. Working Fluid Stability in Large-Scale Organic Rankine Cycle-Units Using Siloxanes—Long-Term Experiences and Fluid Recycling

    Directory of Open Access Journals (Sweden)

    Tobias G. Erhart

    2016-05-01

    Full Text Available The results in this work show the influence of long-term operation on the decomposition of working fluids in eight different organic rankine cycle (ORC power plants (both heat-led and electricity-led in a range of 900 kW el to 2 MW el . All case study plants are using octamethyltrisiloxane (MDM as a working fluid; the facilities are between six to 12 years old. Detailed analyses, including the fluid distribution throughout the cycle, are conducted on one system. All presented fluid samples are analyzed via head space gas chromatography mass spectrometry (HS-GC-MS. Besides the siloxane composition, the influence of contaminants, such as mineral oil-based lubricants (and their components, is examined. In most cases, the original working fluid degrades to fractions of siloxanes with a lower boiling point (low boilers and fractions with a higher boiling point (high boilers. As a consequence of the analyses, a new fluid recycling and management system was designed and tested in one case study plant (Case Study #8. Pre-post comparisons of fluid samples prove the effectiveness of the applied methods. The results show that the recovery of used working fluid offers an alternative to the purchase of fresh fluid, since operating costs can be significantly reduced. For large facilities, the prices for new fluid range from € 15 per liter (in 2006 to € 22 per liter (in 2013, which is a large reinvestment, especially in light of filling volumes of 4000 liters to 7000 liters per unit. Using the aforementioned method, a price of € 8 per liter of recovered MDM can be achieved.

  17. General treatment of the interplay between fluid and radiative transport phenomena in symmetric plasmas: the sulphur lamp as a case study

    International Nuclear Information System (INIS)

    Heijden, Harm van der; Mullen, Joost van der

    2002-01-01

    A general ray-trace method for calculating the effects of radiative transfer in a control volume (CV) fluid code is presented. The method makes use of the structured CV grid of the fluid code, and is suited for geometries with a point or axis of symmetry. In particular, the specific equations for spherical and cylindrical (without z dependence) configurations are developed. The application of this method to local thermal equilibrium (LTE) and non-LTE plasma models is discussed. Various opportunities for sacrificing precision for calculation speed are pointed out. As a case study, the effects of radiative transfer in a sulphur lamp are calculated. Since an LTE description of the molecular radiation yields a computed spectrum that differs significantly from a measured one, the possibility of a non-LTE vibrational distribution of the radiating S 2 -B state is investigated. The results indicate that the vibrational populations may be inversed. (author)

  18. Fluid migration studies in salt

    International Nuclear Information System (INIS)

    Shefelbine, H.C.; Raines, G.E.

    1980-01-01

    This discussion will be limited to the migration of water trapped in the rock salt under the influence of the heat field produced by nuclear waste. This is of concern because hypotheticl scenarios have been advanced in which this fluid movement allows radionuclides to escape to the biosphere. While portions of these scenarios are supported by observation, none of the complete scenarios has been demonstrated. The objectives of the present fluid migration studies are two-fold: 1. determine the character of the trapped fluid in terms of quantity, habitat and chemical constituents; and 2. define the mechanisms that cause the fluid to migrate toward heat sources. Based on the observations to date, fluid migration will not have a major impact on repository integrity. However, the above objectives will be pursued until the impacts, if any, can be quantified

  19. A Study of Two Fluids Mixing in a Helical-Type Micromixer

    International Nuclear Information System (INIS)

    Hu, Y H; Chang, M; Lin, K H

    2006-01-01

    The mixing behavior of two fluids in a passive micromixer with Y-type inlet and helical fluid channel, along with herringbone grooves etched on the base of the fluid channel, was studied with computer simulation technique and experiments. The mixing of pure water and acetone solution under different Reynolds numbers and acetone concentrations were investigated. An image inspection method using the variance in contrast of the image gray level as the measurement parameter was adopted to calculate the mixing efficiency distribution. Inspection results show that the mixing efficiency is decreased with the increase of the concentration of the acetone solution, but the mean mixing efficiency around the outlet can reach to a value of 90% even the Reynolds numbers of the fluids were as low as Re = 1, and the best efficiency for the case of Re = 10 is over 98%. The results show that the proposed micromixer is possible applied to the field of biomedical diagnosis

  20. Subdural fluid collection and hydrocephalus following cervical schwannoma resection: hydrocephalus resolution after spinal pseudomeningocele repair: case report.

    Science.gov (United States)

    Benedetto, Nicola; Cagnazzo, Federico; Gambacciani, Carlo; Perrini, Paolo

    2016-12-01

    The authors report the case of a 31-year-old man who developed neck pain and headache 2 months after the uncomplicated resection of a cervical schwannoma. MR imaging revealed infratentorial subdural fluid collections and obstructive hydrocephalus associated with cervical pseudomeningocele. The clinical symptoms, subdural fluid collections, and ventricular dilation resolved after surgical correction of the pseudomeningocele. This report emphasizes that hydrocephalus may be related to disorders of cerebrospinal fluid flow dynamics induced by cervical pseudomeningocele. In these rare cases, both the hydrocephalus and the symptoms are resolved by the simple correction of the pseudomeningocele.

  1. Simulation of sound waves using the Lattice Boltzmann Method for fluid flow: Benchmark cases for outdoor sound propagation

    NARCIS (Netherlands)

    Salomons, E.M.; Lohman, W.J.A.; Zhou, H.

    2016-01-01

    Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases:

  2. [Clinical evaluation of flomoxef in pediatrics and a study on the penetration into cerebrospinal fluid].

    Science.gov (United States)

    Okada, T; Furukawa, S

    1987-08-01

    The transfer to cerebrospinal fluid of a new oxacephem antibiotic flomoxef (FMOX, 6315-S) and its clinical efficacy against bacterial infections were investigated. 1. In 3 cases of purulent meningitis, cerebrospinal fluid concentrations of FMOX after one shot intravenous injection of 100 mg/kg during the acute stage of infections were 5.12-6.32 micrograms/ml and ratios of FMOX in cerebrospinal fluid in serum were about 5%. During the recovery stage, cerebrospinal fluid concentrations were about 3.8 micrograms/ml and cerebrospinal fluid/serum ratios were about 3.5%. 2. In 1 case of purulent meningitis, the treatment with FMOX was clinically effective but this case was classified as "unevaluable" because other drug was used concomitantly. FMOX was rated effective in other 2 cases of purulent meningitis. Of 9 cases of pneumonia, FMOX was rated very effective in 8 cases and it was rated only effective in the other. Of 4 cases of bronchitis, the drug was rated very effective in 3 cases and only effective in the other. FMOX was rated very effective against 2 cases of tonsillitis, also. 3. As side effects, thrombocytosis was observed in 3 of 20 cases examined. All cases, however, were deemed unrelated to the FMOX treatment and the side effect was only transient as are often found in courses of recovery from infections.

  3. A simple hepatic cyst with elevated serum and cyst fluid CA19-9 levels: a case report

    Directory of Open Access Journals (Sweden)

    Yanai Hidekatsu

    2008-10-01

    Full Text Available Abstract Introduction Simple hepatic cysts rarely cause symptoms, however, occasionally they become symptomatic due to mass effect, rupture, hemorrhage, and infection. We report a patient with a large hepatic cyst with elevated serum and cyst fluid CA19-9 levels. We studied serum and cyst fluid CA19-9 levels in this patient, before and after the intracystic instillation of minocycline hydrochloride. Case presentation A 76-year-old Japanese woman was diagnosed as having an infected hepatic cyst, by physical examination and enhanced abdominal computed tomography. Serum (170 U/ml; reference: Conclusion Our study is the first report to reveal the influence of intracystic instillation of minocycline hydrochloride on serum and cyst fluid CA19-9 levels in a patient with a simple hepatic cyst.

  4. Fluid prediction using rock modelling and reconnaissance. AVO analysis - A case study from the North Sea

    Energy Technology Data Exchange (ETDEWEB)

    Osdal, Bard; Granli, John Reidar

    1998-12-31

    Seismic lithology and fluid phase prediction (LFP) is becoming an important part of seismic interpretation, and can contribute significantly to risk reduction prior to drilling. In this presentation there is focused on quantitative interpretation of the amplitudes in a 2-D dataset, with respect to presence of hydrocarbons. Different aspect of the working producer, like data quality (well data and seismic data), rock modelling and seismic modelling will be illustrated. In the present study only one well has been used for calibration and to investigate the seismic response for different fluid and lithology scenarios. The rock modelling included evaluation of seismic parameter effect for different fluid and porosities. 1 ref., 4 figs.

  5. [Neonatal facial palsy: identification of herpes simplex virus 1 in cerebrospinal fluid. Case report].

    Science.gov (United States)

    Lubián López, Simón; Pérez Guerrero, Juan J; Salazar Oliva, Patricia; Benavente Fernández, Isabel

    2018-06-01

    Neonatal facial palsy is very uncommon and is generally diagnosed at birth. We present the first published case of neonatal facial palsy with identification of herpes simplex virus 1 in cerebrospinal fluid. A 35-day-old male was presented at the Emergency Department with mouth deviation to the left and impossibility of full closure of the right eye. There were no symptoms of infection or relevant medical history. Physical examination was compatible with peripheral facial palsy. Studies performed at admission were normal (blood count, biochemical analysis and coagulation blood tests and cerebrospinal fluid analysis). The patient was admitted on oral prednisolone and intravenous aciclovir. Cranial magnetic resonance was normal. Polymerase chain reaction test for herpes simplex virus 1 in cerebrospinal fluid was reported positive after 48 hours of admission. Patient followed good evolution and received prednisolone for 7 days and acyclovir for 21 days. At discharge, neurological examination was normal. Sociedad Argentina de Pediatría.

  6. Hierarchical Bayesian Modeling of Fluid-Induced Seismicity

    Science.gov (United States)

    Broccardo, M.; Mignan, A.; Wiemer, S.; Stojadinovic, B.; Giardini, D.

    2017-11-01

    In this study, we present a Bayesian hierarchical framework to model fluid-induced seismicity. The framework is based on a nonhomogeneous Poisson process with a fluid-induced seismicity rate proportional to the rate of injected fluid. The fluid-induced seismicity rate model depends upon a set of physically meaningful parameters and has been validated for six fluid-induced case studies. In line with the vision of hierarchical Bayesian modeling, the rate parameters are considered as random variables. We develop both the Bayesian inference and updating rules, which are used to develop a probabilistic forecasting model. We tested the Basel 2006 fluid-induced seismic case study to prove that the hierarchical Bayesian model offers a suitable framework to coherently encode both epistemic uncertainty and aleatory variability. Moreover, it provides a robust and consistent short-term seismic forecasting model suitable for online risk quantification and mitigation.

  7. Fluid-structure interactions in one-dimensional linear cases

    International Nuclear Information System (INIS)

    Schumann, U.

    1979-01-01

    The interaction of pressure waves in a pipe with an elastic endwall (piston) is analyzed using a linear ('acoustic') model. Two transient and two periodic cases are investigated. In the transient cases the motions are initiated by either a sudden pressure drop at the opeen end (breaking membrane) or by a sudden release of the piston from a non-equilibrium position ('snapback'); in the latter case the other end of the pipe is closed. In the periodic cases harmonic oscillations of the piston and the fluid are investigated with the other end of the pipe being either closed or open (kept at constant pressure). The problem is characterized by three non-dimensional numbers (e.g.: Mach-, Strouhal-, and an interaction-number). The solution of the wave equation for the pressure accounting for the coupling to the structure can be reduced analytically to the problem of integrating one ordinary differential equation of second order in time. This differential equation in turn can be integrated analytically at least for a certain time period. At later times this ordinary differential equation is integrated numerically. For the periodic cases eigenvalue-problems arise with an infinite number of solutions. The first few eigensolutions are given. (orig./RW) [de

  8. Magneto-Fluid Dynamics Fundamentals and Case Studies of Natural Phenomena

    CERN Document Server

    Lorrain, Paul; Houle, Stéphane

    2006-01-01

    This book concerns the generation of electric currents and of electric space charges inside conducting media that move in magnetic fields. The authors postulate nothing but the Maxwell equations. They discuss at length the disk dynamo, which serves as a model for the natural self-excited dynamos that generate magnetic fields such as that of sunspots. There are 36 Examples and 13 Case Studies. The Case Studies concern solar phenomena -- magnetic elements, sunspots, spicules, coronal loops -- and the Earth's magnetic field.

  9. Fluid-fluid level on MR image: significance in Musculoskeletal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hye Won; Lee, Kyung Won [Seoul Naitonal University, Seoul (Korea, Republic of). Coll. of Medicine; Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of); Han, Sang Wook; Kang, Heung Sik [Seoul Naitonal University, Seoul (Korea, Republic of). Coll. of Medicine

    1998-01-01

    To evaluate the frequency, number and signal intensity of fluid-fluid levels of musculoskeletal diseases on MR images, and to determine the usefulness of this information for the differentiation of musculoskeletal diseases. MR images revealed fluid-fluid levels in the following diseases : giant cell tumor(6), telangiectatic osteosarcoma(4), aneurysmal bone cyst(3), synovial sarcoma(3), chondroblastoma(2), soft tissue tuberculous abscess(2), hematoma(2), hemangioma (1), neurilemmoma(1), metastasis(1), malignant fibrous histiocytoma(1), bursitis(1), pyogenic abscess(1), and epidermoid inclusion cyst(1). Fourteen benign tumors and ten malignant, three abscesses, and the epidermoid inclusion cyst showed only one fluid-fluid level in a unilocular cyst. On T1-weighted images, the signal intensities of fluid varied, but on T2-weighted images, superior layers were in most cases more hyperintense than inferior layers. Because fluid-fluid layers are a nonspecific finding, it is difficult to specifically diagnose each disease according to the number of fluid-fluid levels or signal intensity of fluid. In spite of the nonspecificity of fluid-fluid levels, they were frequently seen in cases of giant cell tumor, telangiectatic osteosarcoma, aneurysmal bone cycle, and synovial sarcoma. Nontumorous diseases such abscesses and hematomas also demonstrated this finding. (author). 11 refs., 1 tab., 4 figs.

  10. Fluid-fluid level on MR image: significance in Musculoskeletal diseases

    International Nuclear Information System (INIS)

    Chung, Hye Won; Lee, Kyung Won; Han, Sang Wook; Kang, Heung Sik

    1998-01-01

    To evaluate the frequency, number and signal intensity of fluid-fluid levels of musculoskeletal diseases on MR images, and to determine the usefulness of this information for the differentiation of musculoskeletal diseases. MR images revealed fluid-fluid levels in the following diseases : giant cell tumor(6), telangiectatic osteosarcoma(4), aneurysmal bone cyst(3), synovial sarcoma(3), chondroblastoma(2), soft tissue tuberculous abscess(2), hematoma(2), hemangioma (1), neurilemmoma(1), metastasis(1), malignant fibrous histiocytoma(1), bursitis(1), pyogenic abscess(1), and epidermoid inclusion cyst(1). Fourteen benign tumors and ten malignant, three abscesses, and the epidermoid inclusion cyst showed only one fluid-fluid level in a unilocular cyst. On T1-weighted images, the signal intensities of fluid varied, but on T2-weighted images, superior layers were in most cases more hyperintense than inferior layers. Because fluid-fluid layers are a nonspecific finding, it is difficult to specifically diagnose each disease according to the number of fluid-fluid levels or signal intensity of fluid. In spite of the nonspecificity of fluid-fluid levels, they were frequently seen in cases of giant cell tumor, telangiectatic osteosarcoma, aneurysmal bone cycle, and synovial sarcoma. Nontumorous diseases such abscesses and hematomas also demonstrated this finding. (author). 11 refs., 1 tab., 4 figs

  11. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species.

    Science.gov (United States)

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2016-01-01

    Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain of the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. The study population consisted of 100 singleton pregnant women who delivered preterm neonates (Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (>23 ng/mL). (1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; (2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; (3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; (4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and (5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death between patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms and those with both amniotic fluid and gastric fluid positive for Ureaplasma species. Gastric fluid analysis has 100

  12. Molecular dynamics studies of fluid/oil interfaces for improved oil recovery processes.

    Science.gov (United States)

    de Lara, Lucas S; Michelon, Mateus F; Miranda, Caetano R

    2012-12-20

    In our paper, we study the interface wettability, diffusivity, and molecular orientation between crude oil and different fluids for applications in improved oil recovery (IOR) processes through atomistic molecular dynamics (MD). The salt concentration, temperature, and pressure effects on the physical chemistry properties of different interfaces between IOR agents [brine (H(2)O + % NaCl), CO(2), N(2), and CH(4)] and crude oil have been determined. From the interfacial density profiles, an accumulation of aromatic molecules near the interface has been observed. In the case of brine interfaced with crude oil, our calculations indicate an increase in the interfacial tension with increasing pressure and salt concentration, which favors oil displacement. On the other hand, with the other fluids studied (CO(2), N(2), and CH(4)), the interfacial tension decreases with increasing pressure and temperature. With interfacial tension reduction, an increase in fluid diffusivity in the oil phase is observed. We also studied the molecular orientation properties of the hydrocarbon and fluids molecules in the interface region. We perceived that the molecular orientation could be affected by changes in the interfacial tension and diffusivity of the molecules in the interface region with the increased pressure and temperature: pressure (increasing) → interfacial tension (decreasing) → diffusion (increasing) → molecular ordering. From a molecular point of view, the combination of low interfacial tension and high diffusion of molecules in the oil phase gives the CO(2) molecules unique properties as an IOR fluid compared with other fluids studied here.

  13. A study on the unsteady flow of two immiscible micropolar and Newtonian fluids through a horizontal channel: A numerical approach

    Science.gov (United States)

    Devakar, M.; Raje, Ankush

    2018-05-01

    The unsteady flow of two immiscible micropolar and Newtonian fluids through a horizontal channel is considered. In addition to the classical no-slip and hyper-stick conditions at the boundary, it is assumed that the fluid velocities and shear stresses are continuous across the fluid-fluid interface. Three cases for the applied pressure gradient are considered to study the problem: one with constant pressure gradient and the other two cases with time-dependent pressure gradients, viz. periodic and decaying pressure gradient. The Crank-Nicolson approach has been used to obtain numerical solutions for fluid velocity and microrotation for diverse sets of fluid parameters. The nature of fluid velocities and microrotation with various values of pressure gradient, Reynolds number, ratio of viscosities, micropolarity parameter and time is illustrated through graphs. It has been observed that micropolarity parameter and ratio of viscosities reduce the fluid velocities.

  14. CT findings of a unicameral calcaneal bone cyst containing a fluid-fluid level.

    Science.gov (United States)

    Gallagher, Thomas A; Lim-Dunham, Jennifer E; Vade, Aruna

    2007-03-01

    Calcaneal unicameral bone cysts often contain fluid, but rarely contain fluid-fluid levels. We present a case focusing on the CT findings of a large calcaneal bone cyst with a fluid-fluid level and a review of the literature.

  15. Prenatal diagnosis of Bartter syndrome: amniotic fluid aldosterone.

    Science.gov (United States)

    Rachid, Myriam; Dreux, Sophie; Pean de Ponfilly, Gauthier; Vargas-Poussou, Rosa; Czerkiewicz, Isabelle; Chevenne, Didier; Oury, Jean-François; Deschênes, Georges; Muller, Françoise

    2017-04-01

    Bartter syndrome is a severe inherited tubulopathy characterized at birth by salt wasting, severe polyuria, dehydration, growth retardation and secondary hyperaldosteronism. Prenatally, the disease is usually discovered following onset of severe polyhydramnios. We studied amniotic fluid aldosterone concentration in cases of Bartter syndrome and in control groups. Amniotic fluid aldosterone was assayed by radioimmunoassay. We undertook a retrospective case-control study based on 36 cases of postnatally diagnosed Bartter syndrome and 144 controls matched for gestational age. Two controls groups were defined: controls with polyhydramnios (n=72) and control without polyhydramnios (n=72). Amniotic fluid aldosterone was compared between the three groups. The median amniotic fluid aldosterone concentration in the Bartter syndrome group (90 pg/mL) did not differ significantly from that in the controls with polyhydramnios (90 pg/mL, p=0.33) or the controls without polyhydramnios (87 pg/mL, p=0.41). In conclusion, amniotic fluid aldosterone assay cannot be used for prenatal diagnosis of Bartter syndrome.

  16. Chest computed tomography of a patient revealing severe hypoxia due to amniotic fluid embolism: a case report

    Directory of Open Access Journals (Sweden)

    Inui Daisuke

    2010-02-01

    Full Text Available Abstract Introduction Amniotic fluid embolism is one of the most severe complications in the peripartum period. Because its onset is abrupt and fulminant, it is unlikely that there will be time to examine the condition using thoracic computed tomography (CT. We report a case of life-threatening amniotic fluid embolism, where chest CT in the acute phase was obtained. Case presentation A 22-year-old Asian Japanese primiparous woman was suspected of having an amniotic fluid embolism. After a Cesarean section for cephalopelvic disproportion, her respiratory condition deteriorated. Her chest CT images were examined. CT findings revealed diffuse homogeneous ground-glass shadow in her bilateral peripheral lung fields. She was therefore transferred to our hospital. On admission to our hospital's intensive care unit, she was found to have severe hypoxemia, with SpO2 of 50% with a reservoir mask of 15 L/min oxygen. She was intubated with the support of noninvasive positive pressure ventilation. She was successfully extubated on the sixth day, and discharged from the hospital on the twentieth day. Conclusion This is the first case report describing amniotic fluid embolism in which CT revealed an acute respiratory distress syndrome-like shadow.

  17. MRI of subdural fluid collections in infants

    International Nuclear Information System (INIS)

    Fukushima, Tsuneyuki; Takagi, Takuji; Nagai, Hajime; Banno, Tatsuo

    1988-01-01

    Twenty cases of subdural fluid collectioin in infants were examined by MRI (0.5 Tesla). The findings of MRI were classified into 3 groups as follows: Group I: Blood component is observed in the entire subdural fluid (4 cases, 20 %). Group II: Blood component is observed in a part of the subdural fluid (4 cases, 20 %). Group III: Subdural fluid consists of pure CSF (12 cases, 60 %). In general, operative treatment should be considered for cases which have blood components in the subdural space and/or symptoms and signs of increased ICP. In group I, operation was performed on 2 cases (50 %). In group II, subdural fluid collections were associated with dilated subarachnoid spaces and 2 cases were operated on in this group (50 %). In group III, only one case was operated on (8.3 %) and subdural fluid collections disappeared spontaneously in 4 cases of this group. The precise anatomical location of subdural fluid collections could not be decided in several cases even by MRI. The cases which had blood components, tended to demonstrate membranes frequently on MRI. However, the existence of blood components did not affect the DQ S significantly. The prognosis of subdural fluid collection is supposedly related to the degree of preexistent brain damage. (author)

  18. Characterisation of dissolved organic compounds in hydrothermal fluids by stir bar sorptive extraction - gas chomatography - mass spectrometry. Case study: the Rainbow field (36°N, Mid-Atlantic Ridge

    Directory of Open Access Journals (Sweden)

    Konn Cecile

    2012-11-01

    Full Text Available Abstract The analysis of the dissolved organic fraction of hydrothermal fluids has been considered a real challenge due to sampling difficulties, complexity of the matrix, numerous interferences and the assumed ppb concentration levels. The present study shows, in a qualitative approach, that Stir Bar Sorptive Extraction (SBSE followed by Thermal Desorption – Gas Chromatography – Mass Spectrometry (TD-GC-MS is suitable for extraction of small sample volumes and detection of a wide range of volatile and semivolatile organic compounds dissolved in hydrothermal fluids. In a case study, the technique was successfully applied to fluids from the Rainbow ultramafic-hosted hydrothermal field located at 36°14’N on the Mid-Atlantic Ridge (MAR. We show that n-alkanes, mono- and poly- aromatic hydrocarbons as well as fatty acids can be easily identified and their retention times determined. Our results demonstrate the excellent repeatability of the method as well as the possibility of storing stir bars for at least three years without significant changes in the composition of the recovered organic matter. A preliminary comparative investigation of the organic composition of the Rainbow fluids showed the great potential of the method to be used for assessing intrafield variations and carrying out time series studies. All together our results demonstrate that SBSE-TD-GC-MS analyses of hydrothermal fluids will make important contributions to the understanding of geochemical processes, geomicrobiological interactions and formation of mineral deposits.

  19. Results of six years of cytogenetic studies in amniotic fluid

    Directory of Open Access Journals (Sweden)

    Enelis Reyes Reyes

    2015-10-01

    Full Text Available Background: research into different genetic diseases is one of the preventive programs of paramount importance at public health level. The early detection of chromosomopathies and the establishment of an appropriate strategy reduce the morbidity-morality rate and improve the patients’ quality of life.Objective: to describe the behavior of the results of the cytogenetic studies in the amniotic fluid of pregnant women from Las Tunas province during six years: from 2008 to 2014.Methods: a retrospective and descriptive study was carried out to assess the results of cytogenetic studies in amniotic liquid during six years: from 2008 to 2014. The statistical records were checked and the results, the indication criteria, the behavior of the age groups in women advanced in age and the diagnosed chromosomopathies were assessed.Results: the samples with results that exceeded the non-conclusive and positive women prevailed; 2, 3 positive cases of chromosomopathies were diagnosed out of 100 studied women at risk; pregnant women of advanced gestational years prevailed as indication criterion, being the 37 to 40 years old age group the predominant one; in the positive cases, numeric chromosomopathies of the type trisomy 21 or Down’s syndrome prevailed, with a frequency of 1, 2 out of 100 pregnant women at risk.Conclusions: the program of the cytogenetic diagnosis in the amniotic fluid has been an effective tool to detect congenital prenatal defects by chromosomopathies, very useful in the process of genetic advice.

  20. Introducing Innovative Approaches to Learning in Fluid Mechanics: A Case Study

    Science.gov (United States)

    Gynnild, Vidar; Myrhaug, Dag; Pettersen, Bjornar

    2007-01-01

    The purpose of the current article is to examine the impact of laboratory demonstrations and computer visualizations on learning in a third-year fluid mechanics course at Norwegian University of Science and Technology (NTNU). As a first step, on entering the course, students were exposed to a laboratory demonstration focusing on the nature of…

  1. A case of perforated sigmoid diverticulitis in which gram staining of ascitic fluid was useful for diagnosis.

    Science.gov (United States)

    Tsuchida, Junko; Fujita, Shouhei; Kawano, Fumihiro; Tsukamoto, Ryoichi; Honjo, Kunpei; Naito, Shigetoshi; Ishiyama, Shun; Miyano, Shozo; Machida, Michio; Kitabatake, Toshiaki; Fujisawa, Minoru; Kojima, Kuniaki; Ogura, Kanako; Matsumoto, Toshiharu

    2014-01-01

    An 85-year-old woman was admitted to our hospital for steroid therapy for relapsing nephrotic syndrome. During hospitalization, she complained of sudden epigastric pain at night. Although there were signs of peritoneal irritation, CT showed a large amount of ascitic fluid, but no free intraperitoneal gas. Gram staining of ascitic fluid obtained by abdominal paracentesis showed Gram-negative rods, which raised a strong suspicion of gastrointestinal perforation and peritonitis. Therefore, emergency surgery was performed. Exploration of the colon showed multiple sigmoid diverticula, one of which was perforated. The patient underwent an emergency Hartmann's procedure. Imaging studies failed to reveal any evidence of gastrointestinal perforation, presenting a diagnostic challenge. However, a physician performed rapid Gram staining of ascitic fluid at night when laboratory technicians were absent, had a strong suspicion of gastrointestinal perforation, and performed emergency surgery. Gram staining is superior in rapidity, and ascitic fluid Gram staining can aid in diagnosis, suggesting that it should be actively performed. We report this case, with a review of the literature on the significance of rapid diagnosis by Gram staining.

  2. Cerebrospinal fluid otorrhea and pseudomonal meningitis in a child with Mondini dysplasia: case report.

    Science.gov (United States)

    Hernandez, R Nick; Changa, Abhinav R; Bassani, Luigi; Jyung, Robert W; Liu, James K

    2015-09-01

    Mondini dysplasia is a rare congenital inner ear malformation that presents with abnormal cochlear development with accompanied vestibular dilation and vestibular aqueduct enlargement. This dysfunctional anatomy provides the potential for sensorineural hearing deficits, cerebrospinal fluid leaks, and severe cases of recurrent meningitis. We present the case of a child with Mondini dysplasia who presented with unilateral hearing loss and cerebrospinal fluid (CSF) otorrhea that was surgically repaired through a combined middle fossa/transmeatal middle ear approach to alleviate any recurrence of infection and cerebrospinal fluid otorrhea. Postoperatively, the patient remained neurologically stable without any further CSF leakage. CSF cultures revealed a Pseudomonas aeruginosa infection, a rare occurrence within the context of Mondini dysplasia. Retrograde bacterial spread from the external ear canal into the CSF space has been theorized as the possible pathogenesis of the resulting meningitis. The patient was successfully treated with intravenous antibiotics without any neurologic complications. Although Mondini dysplasia is a rare malformation, the life-threatening sequelae of meningitis that can result from the dysfunctional anatomy makes it a condition that requires elevated clinical vigilance, especially when considering children with hearing loss associated with recurrent meningitis, otorrhea, or rhinorrhea.

  3. Connection Between Thermodynamics and Dynamics of Simple Fluids in Pores: Impact of Fluid-Fluid Interaction Range and Fluid-Solid Interaction Strength.

    Science.gov (United States)

    Krekelberg, William P; Siderius, Daniel W; Shen, Vincent K; Truskett, Thomas M; Errington, Jeffrey R

    2017-08-03

    Using molecular simulations, we investigate how the range of fluid-fluid (adsorbate-adsorbate) interactions and the strength of fluid-solid (adsorbate-adsorbent) interactions impact the strong connection between distinct adsorptive regimes and distinct self-diffusivity regimes reported in [Krekelberg, W. P.; Siderius, D. W.; Shen, V. K.; Truskett, T. M.; Errington, J. R. Langmuir 2013 , 29 , 14527-14535]. Although increasing the fluid-fluid interaction range changes both the thermodynamics and the dynamic properties of adsorbed fluids, the previously reported connection between adsorptive filling regimes and self-diffusivity regimes remains. Increasing the fluid-fluid interaction range leads to enhanced layering and decreased self-diffusivity in the multilayer-formation regime but has little effect on the properties within film-formation and pore-filling regimes. We also find that weakly attractive adsorbents, which do not display distinct multilayer formation, are hard-sphere-like at super- and subcritical temperatures. In this case, the self-diffusivity of the confined and bulk fluid has a nearly identical scaling-relationship with effective density.

  4. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  5. The correlation between histologic placentitis and amnionitis and the amnioniotic fluid's inflammatory cytokines in case of spontaneous pre-term labor with intact membrane

    Directory of Open Access Journals (Sweden)

    Agus Abadi

    2001-12-01

    Full Text Available Pre-term labor is presumed to result from spreading of lower genital infection to upper part, subsequently to decidual and choioamniotic tissues. Host response to this injury include the expression of protein which is responsible to the inflammatory reactions. The expression of the inflammatory cytokines such as IL-1β, IL-6, IL-8 and TNF-α increase in case of infection.These cytokines may play an essential role in the pathophysiology of spontaneous pretem labor with intact membrane.An observational analytic cohort study was caried out on cases of spontaneous pre-tefln labor with intact membrane. The objectives of this study are to examine the relationship between l the histologic amnionitis and placentitis and the incidence of preterm delivery,2 the expression of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α and the incidence of preterm delivery, 3 the level of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α and the grade of histologic amnionitis and placentitis in case of pre-term labor with intact membrane. Cases of spontaneous Pre'teftn labor with intact membrane which underwent transabdominal amniocentesis at admission and managed as standard procedure for pre-term labor with intact membrane. Atl of the cases were observed until the delivery of the baby, eithir preterm or term. The membrane and the placentawere cut postnatally and then the histologic acute inflammation eyaluated based on the criteria of Salafia.The level of amniotic fluid IL-1β, IL-6, IL-8 and TNF-α were analyzed quantitatively by Elisa method. This study showed thet the degree of histologic amnionitis and placentitis, and the level of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α were significantly higher in pre-term compared to terrn deliveries (p<0.05 and lhere were a positive correlation between the grade of histoLogic inflammation and the level of amniotic fluid's cytokines (Spearmann Rank Conelation test; p<0,05 in cases of preterm labor with intact membrane. The

  6. Spinal cerebrospinal fluid seeding of a clival chordoma; A case report

    International Nuclear Information System (INIS)

    Baek, Seung Hwan; Yu, In Kyu; Kim, Seong Min; Park, Ki Seok; Son, Hyun Jin

    2015-01-01

    Chordomas originate from remnants of the embryonic notochord and account for < 2% of all malignant bone tumors. Chordomas have a high rate of local recurrence. However, spinal cerebrospinal fluid (CSF) seeding of a chordoma is extremely rare. Here, we present a very rare case of clival chordoma with spinal seeding. Radiologists should consider spinal CSF seeding of a clival chordoma, particularly when accompanied by signs of dural perforation or caudal extension

  7. Spinal cerebrospinal fluid seeding of a clival chordoma; A case report

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Seung Hwan; Yu, In Kyu; Kim, Seong Min; Park, Ki Seok; Son, Hyun Jin [Eulji University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    Chordomas originate from remnants of the embryonic notochord and account for < 2% of all malignant bone tumors. Chordomas have a high rate of local recurrence. However, spinal cerebrospinal fluid (CSF) seeding of a chordoma is extremely rare. Here, we present a very rare case of clival chordoma with spinal seeding. Radiologists should consider spinal CSF seeding of a clival chordoma, particularly when accompanied by signs of dural perforation or caudal extension.

  8. A numerical study of bubble interactions in Rayleigh--Taylor instability for compressible fluids

    International Nuclear Information System (INIS)

    Glimm, J.; Li, X.L.; Menikoff, R.; Sharp, D.H.; Zhang, Q.

    1990-01-01

    The late nonlinear and chaotic stage of Rayleigh--Taylor instability is characterized by the evolution of bubbles of the light fluid and spikes of the heavy fluid, each penetrating into the other phase. This paper is focused on the numerical study of bubble interactions and their effect on the statistical behavior and evolution of the bubble envelope. Compressible fluids described by the two-fluid Euler equations are considered and the front tracking method for numerical simulation of these equations is used. Two major phenomena are studied. One is the dynamics of the bubbles in a chaotic environment and the interaction among neighboring bubbles. Another one is the acceleration of the overall bubble envelope, which is a statistical consequence of the interactions of bubbles. The main result is a consistent analysis, at least in the approximately incompressible case of these two phenomena. The consistency encompasses the analysis of experiments, numerical simulation, simple theoretical models, and variation of parameters. Numerical simulation results that are in quantitative agreement with laboratory experiment for one-and-one-half (1 1/2) generations of bubble merger are presented. To the authors' knowledge, computations of this accuracy have not previously been obtained

  9. Ascitic Fluid Culture In Cirrhotic Patients With Spontaneous Bacterial Peritonitis

    International Nuclear Information System (INIS)

    Sajjad, M.; Khan, Z.A.; Khan, M.S.

    2016-01-01

    Objective: To determine the frequency and compare the culture yield of bacterial isolation by conventional and blood culture BACTEC bottle techniques in cirrhotic patients with spontaneous bacterial peritonitis (SBP). Study Design: Cross-sectional comparative study. Place and Duration of Study: Pathology Department, Bannu Medical College, Bannu, KPK, from January 2012 to December 2013. Methodology: Paracentesis of 20 ml of ascitic fluid tapped from cirrhotic patients with SBP was carried out by a single technologist. The analysis included differential leukocyte count (DLC), while 5 ml each of the fluid was inoculated into conventional culture media and BACTEC blood culture bottle. All the data were analysed on (SPSS) version 16 to determine frequencies with percentages and mean values with standard deviation. Chi-square test was used for comparing the yield of conventional and blood culture bottle methods. P-value was considered significant if < 0.05. Results: In 105 cases of ascitic fluid analyses, 27 (25.72 percent) had positive ascitic fluid culture whereas 78 (74.28 percent) had negative ascitic fluid culture. Ascitic fluid culture was positive in 6 cases by conventional culture media and in 27 cases by BACTEC culture bottle media (p < 0.001). Bacterial isolation was obtained by both culture methods in 6 cases (p < 0.001). Conclusion: Direct bedside inoculation of ascitic fluid by BACTEC culture bottle method has better yield as compared to conventional culture method. (author)

  10. [Anaphylactic reactions to modified fluid gelatins. (A case of allergy to Plasmagel)].

    Science.gov (United States)

    Saissy, J M; Legoury, O; Bonvalot, C; Vilette, B

    1980-01-01

    A case of anaphylactic reaction to an infusion of modified fluid gelatin (Plasmagel) which occurred just before the induction of anaesthesia is reported. The allergic origin of this side effect was sought by a human basophil degranulation test (Benveniste test) which proved to be positive. Intolerance reactions to gelatins have up to now been little described in the French literature (in contrast to the German literature). Their mechanism remains poorly understood, even though there are many arguments in favour of a sensitivation phenomenon which would confirm the antigenic role, denied by some, of modified fluid gelatins employed in human clinical use (with the possibility of crossover allergy). The diagnosis and treatment of such complications are reviewed in the light of their mechanism.

  11. Dynamic analysis of a nuclear reactor with fluid-structure interaction

    International Nuclear Information System (INIS)

    Sigrist, Jean-Francois; Broc, Daniel; Laine, Christian

    2007-01-01

    The present paper is related to the dynamic (shock) analysis of a naval propulsion (on-board) reactor with fluid-structure interaction modelling. In a previous study, low frequency analysis has been performed; the present study deals with high frequency analysis, i.e. taking into account compressibility effects in the fluid medium. Elasto-acoustic coupling effects are studied and described in the industrial case. The coupled problem is formulated using the so-called (u, p, φ) formulation which yields symmetric matrices. A modal analysis is first performed on the fluid problem alone, then for the coupled fluid-structure problem in the following cases: (i) with incompressible fluid; (ii) with compressible fluid at standard pressure and temperature conditions; (iii) with compressible fluid at the operating pressure and temperature conditions. Elasto-coupling effects are then highlighted, in particular through the calculation of an elastic energy ratio. As a general conclusion, compressibility effects are proved significant in the dynamic response of the reactor in the high frequency range

  12. Study and discretization of kinetic models and fluid models at low Mach number

    International Nuclear Information System (INIS)

    Dellacherie, Stephane

    2011-01-01

    This thesis summarizes our work between 1995 and 2010. It concerns the analysis and the discretization of Fokker-Planck or semi-classical Boltzmann kinetic models and of Euler or Navier-Stokes fluid models at low Mach number. The studied Fokker-Planck equation models the collisions between ions and electrons in a hot plasma, and is here applied to the inertial confinement fusion. The studied semi-classical Boltzmann equations are of two types. The first one models the thermonuclear reaction between a deuterium ion and a tritium ion producing an α particle and a neutron particle, and is also in our case used to describe inertial confinement fusion. The second one (known as the Wang-Chang and Uhlenbeck equations) models the transitions between electronic quantified energy levels of uranium and iron atoms in the AVLIS isotopic separation process. The basic properties of these two Boltzmann equations are studied, and, for the Wang-Chang and Uhlenbeck equations, a kinetic-fluid coupling algorithm is proposed. This kinetic-fluid coupling algorithm incited us to study the relaxation concept for gas and immiscible fluids mixtures, and to underline connections with classical kinetic theory. Then, a diphasic low Mach number model without acoustic waves is proposed to model the deformation of the interface between two immiscible fluids induced by high heat transfers at low Mach number. In order to increase the accuracy of the results without increasing computational cost, an AMR algorithm is studied on a simplified interface deformation model. These low Mach number studies also incited us to analyse on cartesian meshes the inaccuracy at low Mach number of Godunov schemes. Finally, the LBM algorithm applied to the heat equation is justified

  13. A Rare Case of Spontaneous Pneumocephalus Associated with Nontraumatic Cerebrospinal Fluid Leak

    Directory of Open Access Journals (Sweden)

    Murad Baba

    2016-01-01

    Full Text Available Introduction. Spontaneous nontraumatic pneumocephalus (PNC and cerebrospinal fluid (CSF leaks are both very uncommon conditions. We report a rare case of spontaneous pneumocephalus associated with CSF leak secondary to right sphenoid sinus bony defect without history of trauma. Case Description. 51-year-old Hispanic female with past medical history of hypertension and idiopathic intracranial hypertension (Pseudotumor Cerebri presented to the emergency room complaining of headache and clear discharge from the right nostril. Physical examination was significant for right frontal sinus tenderness and clear discharge from right nostril. Computed Tomography (CT scan of the brain showed moderate amount of extra-axial air within the right cerebral hemisphere indicative of pneumocephalus. CT scan of facial bones showed bony defect along the right sphenoid sinus with abnormal CSF collection. The patient was started on intravenous antibiotics for meningitis prophylaxis and subsequently underwent transsphenoidal repair of cerebrospinal fluid leak with abdominal fat graft. CSF rhinorrhea stopped completely after the surgery with near complete resolution of pneumocephalus before discharge. Conclusions. Early identification of pneumocephalus and surgical intervention can help decrease the morbidity and avoid possible complications. Idiopathic intracranial hypertension, although rare, can lead to CSF leak and pneumocepahlus.

  14. Comparative study of Eyring and Carreau fluids in a suspension of dust and nickel nanoparticles with variable conductivity

    Science.gov (United States)

    Mamatha Upadhya, S.; Mahesha; Raju, C. S. K.

    2018-04-01

    A theoretical analysis is carried out to investigate the magnetohydrodynamic unsteady flow of Eyring-Powell and Carreau non-Newtonian fluids in a suspension of dust and nickel nanoparticles by considering variable thermal conductivity and thermal radiation. Dispersion of nickel nanoparticles in dusty fluids finds applications in heat exchanger systems, rechargeable batteries, chemical catalysts, metallurgy, conducting paints, magnetic recording media, drug delivery, nanofibers, textiles, etc. The initially arising set of physical governing partial differential equations is transformed to ordinary differential equations (ODEs) with the aid of similarity transformations. Consequentially, the nonlinear ODEs are solved numerically through the Runge-Kutta Fehlberg scheme (RKFS). The computational results for non-dimensional temperature and velocity profiles are presented through graphs. Furthermore, the numerical values of friction factor and heat transfer rate are tabulated numerically for the unsteady and steady cases of the Eyring and Carreau fluid cases and of the dusty non-Newtonian (φ=0) and the dusty non-Newtonian nanofluid (φ≠ 0) cases of the unsteady flow. We also validated the present results with previous published studies and found them to be highly satisfactory. The formulated model reveals that the rate of heat transfer is higher in the mixture of the nickel + Eyring-Powell case compared to the nickel + Carreau case. From this we can highlight that, depending on the industrial appliances, we can use heating or cooling processes for Eyring and Carreau fluids, respectively.

  15. Buffer fluid

    Energy Technology Data Exchange (ETDEWEB)

    Mirzadzhanzade, A Kh; Dedusanko, G Ya; Dinaburg, L S; Markov, Yu M; Rasizade, Ya N; Rozov, V N; Sherstnev, N M

    1979-08-30

    A drilling fluid is suggested for separating the drilling and plugging fluids which contains as the base increased solution of polyacrylamide and additive. In order to increase the viscoelastic properties of the liquid with simultaneous decrease in the periods of its fabrication, the solution contains as an additive dry bentonite clay. In cases of the use of a buffer fluid under conditions of negative temperatures, it is necessary to add to it table salt or ethylene glycol.

  16. Fluid mechanics in fluids at rest.

    Science.gov (United States)

    Brenner, Howard

    2012-07-01

    Using readily available experimental thermophoretic particle-velocity data it is shown, contrary to current teachings, that for the case of compressible flows independent dye- and particle-tracer velocity measurements of the local fluid velocity at a point in a flowing fluid do not generally result in the same fluid velocity measure. Rather, tracer-velocity equality holds only for incompressible flows. For compressible fluids, each type of tracer is shown to monitor a fundamentally different fluid velocity, with (i) a dye (or any other such molecular-tagging scheme) measuring the fluid's mass velocity v appearing in the continuity equation and (ii) a small, physicochemically and thermally inert, macroscopic (i.e., non-Brownian), solid particle measuring the fluid's volume velocity v(v). The term "compressibility" as used here includes not only pressure effects on density, but also temperature effects thereon. (For example, owing to a liquid's generally nonzero isobaric coefficient of thermal expansion, nonisothermal liquid flows are to be regarded as compressible despite the general perception of liquids as being incompressible.) Recognition of the fact that two independent fluid velocities, mass- and volume-based, are formally required to model continuum fluid behavior impacts on the foundations of contemporary (monovelocity) fluid mechanics. Included therein are the Navier-Stokes-Fourier equations, which are now seen to apply only to incompressible fluids (a fact well-known, empirically, to experimental gas kineticists). The findings of a difference in tracer velocities heralds the introduction into fluid mechanics of a general bipartite theory of fluid mechanics, bivelocity hydrodynamics [Brenner, Int. J. Eng. Sci. 54, 67 (2012)], differing from conventional hydrodynamics in situations entailing compressible flows and reducing to conventional hydrodynamics when the flow is incompressible, while being applicable to both liquids and gases.

  17. Investigation of problems of closing of geophysical cracks in thermoelastic media in the case of flow of fluids with impurities

    Science.gov (United States)

    Martirosyan, A. N.; Davtyan, A. V.; Dinunts, A. S.; Martirosyan, H. A.

    2018-04-01

    The purpose of this article is to investigate a problem of closing cracks by building up a layer of sediments on surfaces of a crack in an infinite thermoelastic medium in the presence of a flow of fluids with impurities. The statement of the problem of closing geophysical cracks in the presence of a fluid flow is presented with regard to the thermoelastic stress and the influence of the impurity deposition in the liquid on the crack surfaces due to thermal diffusion at the fracture closure. The Wiener–Hopf method yields an analytical solution in the special case without friction. Numerical calculations are performed in this case and the dependence of the crack closure time on the coordinate is plotted. A similar spatial problem is also solved. These results generalize the results of previous studies of geophysical cracks and debris in rocks, where the closure of a crack due to temperature effects is studied without taking the elastic stresses into account.

  18. Periodontal disease and spontaneous preterm birth: a case control study

    Directory of Open Access Journals (Sweden)

    Eley Barry

    2006-07-01

    Full Text Available Abstract Background Several studies have suggested an association between periodontal disease and prematurity but this finding has not been consistently observed. Methods Case control study. Cases (n = 50 were women who had delivered after spontaneous preterm labor at Results There was no difference in the proportion of sites with significant attachment loss (≥3 mm: Cases-3.2%, Controls-2.2% p = 0.21. The gingival crevicular fluid concentrations of elastase and gingipain were elevated in cases vs. controls 238.8 uU/ul vs. 159.6 uU/ul p = .007 and 2.70 uU/ul vs. 1.56 uU/ul p = .001. On multivariate analysis, the mean log concentration of elastase, but not of gingipain, remained a significant predictor of preterm labor p = .0.015. Conclusion We found no evidence that clinical periodontal disease is associated with spontaneous preterm birth. Elevated gingival crevicular fluid levels of elastase were associated with preterm birth but further research is needed before this can be assumed to be a causal relationship.

  19. A study on self-excited sloshing due to the fluid discharge over a flexible weir

    International Nuclear Information System (INIS)

    Nagakura, Hiroshi; Kaneko, Shigehiko.

    1995-01-01

    An analytical model for the fluid-elastic instability as observed in Super-Phenix-1 LMFBR is proposed. This fluid-structure system is constituted by the flexible weir and adjoining fluid plenums, and the fluid is discharged from the upstream plenum to the downstream plenum over a flexible weir. The characteristic equation of the system is derived for the case in which the weir vibrates at the frequency of the downstream plenum sloshing. The effects of the fluid level difference between the upstream and the downstream plenum and weir rigidity are examined, and the mechanism for instability is discussed. (author)

  20. Role of intrapartum transcervical amnioinfusion in patients with meconium-stained amniotic fluid.

    Science.gov (United States)

    Bhatia, Pushpa; Reena, Kumari; Nangia, Sangita

    2013-03-01

    The study was undertaken to evaluate maternal, perinatal outcomes following transcervical intrapartum amnioinfusion in women with meconium-stained amniotic fluid. A prospective comparative study was conducted on 100 women with meconium-stained amniotic fluid in labor. Group A: study group (50 cases) received amnioinfusion. Group B: control group (50 cases) did not receive amnioinfusion. FHR monitoring was done using cardiotocography. Significant relief from variable decelerations was seen in 68.18 % cases in the amnioinfusion group as compared to 7.1 % cases in the control group. 78 % cases who were given amnioinfusion had vaginal delivery as compared to 18 % cases in the control group. Fourteen percent cases in the study group had cesarean delivery as compared to 68 % cases in the control group. Meconium aspiration syndrome was seen in six percent neonates in the study group as compared to 20 % in the control group. Two neonates died in the control group due to meconium aspiration syndrome. There was no maternal mortality or major maternal complication. Intrapartum transcervical amnioinfusion is valuable in patients with meconium-stained amniotic fluid.

  1. Computational fluid dynamics study of viscous fingering in supercritical fluid chromatography.

    Science.gov (United States)

    Subraveti, Sai Gokul; Nikrityuk, Petr; Rajendran, Arvind

    2018-01-26

    Axi-symmetric numerical simulations are carried out to study the dynamics of a plug introduced through a mixed-stream injection in supercritical fluid chromatographic columns. The computational fluid dynamics model developed in this work takes into account both the hydrodynamics and adsorption equilibria to describe the phenomena of viscous fingering and plug effect that contribute to peak distortions in mixed-stream injections. The model was implemented into commercial computational fluid dynamics software using user-defined functions. The simulations describe the propagation of both the solute and modifier highlighting the interplay between the hydrodynamics and plug effect. The simulated peaks showed good agreement with experimental data published in the literature involving different injection volumes (5 μL, 50 μL, 1 mL and 2 mL) of flurbiprofen on Chiralpak AD-H column using a mobile phase of CO 2 and methanol. The study demonstrates that while viscous fingering is the main source of peak distortions for large-volume injections (1 mL and 2 mL) it has negligible impact on small-volume injections (5 μL and 50 μL). Band broadening in small-volume injections arise mainly due to the plug effect. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  2. On the micromechanics of slip events in sheared, fluid-saturated fault gouge

    Science.gov (United States)

    Dorostkar, Omid; Guyer, Robert A.; Johnson, Paul A.; Marone, Chris; Carmeliet, Jan

    2017-06-01

    We used a three-dimensional discrete element method coupled with computational fluid dynamics to study the poromechanical properties of dry and fluid-saturated granular fault gouge. The granular layer was sheared under dry conditions to establish a steady state condition of stick-slip dynamic failure, and then fluid was introduced to study its effect on subsequent failure events. The fluid-saturated case showed increased stick-slip recurrence time and larger slip events compared to the dry case. Particle motion induces fluid flow with local pressure variation, which in turn leads to high particle kinetic energy during slip due to increased drag forces from fluid on particles. The presence of fluid during the stick phase of loading promotes a more stable configuration evidenced by higher particle coordination number. Our coupled fluid-particle simulations provide grain-scale information that improves understanding of slip instabilities and illuminates details of phenomenological, macroscale observations.

  3. Severe Sepsis in Severely Malnourished Young Bangladeshi Children with Pneumonia: A Retrospective Case Control Study.

    Directory of Open Access Journals (Sweden)

    Mohammod Jobayer Chisti

    Full Text Available In developing countries, there is no published report on predicting factors of severe sepsis in severely acute malnourished (SAM children having pneumonia and impact of fluid resuscitation in such children. Thus, we aimed to identify predicting factors for severe sepsis and assess the outcome of fluid resuscitation of such children.In this retrospective case-control study SAM children aged 0-59 months, admitted to the Intensive Care Unit (ICU of the Dhaka Hospital of the International Centre for Diarrhoeal Disease Research, Bangladesh from April 2011 through July 2012 with history of cough or difficult breathing and radiologic pneumonia, who were assessed for severe sepsis at admission constituted the study population. We compared the pneumonic SAM children with severe sepsis (cases = 50 with those without severe sepsis (controls = 354. Severe sepsis was defined with objective clinical criteria and managed with fluid resuscitation, in addition to antibiotic and other supportive therapy, following the standard hospital guideline, which is very similar to the WHO guideline.The case-fatality-rate was significantly higher among the cases than the controls (40% vs. 4%; p<0.001. In logistic regression analysis after adjusting for potential confounders, lack of BCG vaccination, drowsiness, abdominal distension, acute kidney injury, and metabolic acidosis at admission remained as independent predicting factors for severe sepsis in pneumonic SAM children (p<0.05 for all comparisons.We noted a much higher case fatality among under-five SAM children with pneumonia and severe sepsis who required fluid resuscitation in addition to standard antibiotic and other supportive therapy compared to those without severe sepsis. Independent risk factors and outcome of the management of severe sepsis in our study children highlight the importance for defining optimal fluid resuscitation therapy aiming at reducing the case fatality in such children.

  4. Delayed sub-aponeurotic fluid collections in infancy: Three cases and a review of the literature.

    Science.gov (United States)

    Petraglia, Anthony L; Moravan, Michael J; Marky, Andrew H; Silberstein, Howard J

    2010-07-21

    Sub-aponeurotic fluid collections (SFCs) in the neonatal period are poorly described in the literature. We describe the occurrence, possible etiologies and treatment of sub-aponeurotic fluid collections following the neonatal period. We present 3 cases of previously healthy children who developed soft, fluctuant, extracranial masses several weeks after birth. All 3 children were seen by a pediatric neurosurgeon after parents noticed scalp masses between 5 and 9 weeks of age. All 3 children were found to be otherwise healthy. Two of the children were born via C-section and 1 child was born vaginally. The vaginal delivery was described as difficult and utilized vacuum assist. Scalp electrodes were placed in all 3 children for intensive monitoring during labor. These children received plain skull x-rays to assess for abnormalities, and 2 of the children underwent a non-contrast brain CT scan to better characterize the fluid collection. Plain x-rays and CT scans showed no abnormalities of the skull or ventricles. In both patients who underwent a CT scan, a soft tissue prominence was noted with a Hounsfield unit similar to water. All cases resolved between 5 and 9 weeks after initial presentation, with no long-term sequelae. SFCs presenting after the neonatal period are usually associated with benign soft tissue swellings. Use of fetal scalp electrodes has been shown to cause cerebrospinal fluid (CSF) leakage in the neonatal period and may result in delayed SFC. This condition is benign, and the recommended course of treatment is conservative management.

  5. Myonecrosis in Sickle Cell Anemia: Case Study.

    Science.gov (United States)

    Turaga, Lalita Prabha; Boddu, Prajwal; Kipferl, Steve; Basu, Anupam; Yorath, Martin

    2017-01-30

    BACKGROUND Myonecrosis is one of the more poorly studied, painful manifestations of sickle cell crisis. Medical literature is sparse detailing the manifestations and management of such symptoms. In myonecrosis, red cells containing sickle hemoglobin become rigid, resulting in reduced blood flow and myonecrosis. CASE REPORT We present a case study of a patient in sickle cell crisis with an episode of acute pain and swelling to the intrinsic muscles of the foot as a prominent feature of the crises. Although muscle biopsy is considered the gold standard for the diagnosis of myositis or myonecrosis, a low intensity signal on T1 and high intensity signal on T2 at the affected muscle belly can be as conclusive as imaging studies. In an actively sickling patient any invasive intervention should be avoided as it can result in ischemic necrosis of the tissues, due to interruption of capillary flow in end-arteries. CONCLUSIONS Early recognition is critical in sickle cell disease management, allowing for prompt and aggressive fluid resuscitation which remains a cornerstone in the management of most sickle cell vaso-occlusive crises. In this instance, off loading the extremity and early fluid resuscitation resolved the pain and swelling and prevented myonecrosis.

  6. Feet swelling in a multistage ultraendurance triathlete: a case study

    Directory of Open Access Journals (Sweden)

    Knechtle B

    2015-10-01

    Full Text Available Beat Knechtle,1 Matthias Alexander Zingg,2 Patrizia Knechtle,1 Thomas Rosemann,2 Christoph Alexander Rüst2 1Gesundheitszentrum St Gallen, St Gallen, 2Institute of Primary Care, University of Zurich, Zurich, Switzerland Abstract: Recent studies investigating ultraendurance athletes showed an association between excessive fluid intake and swelling of the lower limbs such as the feet. To date, this association has been investigated in single-stage ultraendurance races, but not in multistage ultraendurance races. In this case study, we investigated a potential association between fluid intake and feet swelling in a multistage ultraendurance race such as a Deca Iron ultratriathlon with ten Ironman triathlons within 10 consecutive days. A 49-year-old well-experienced ultratriathlete competed in autumn 2013 in the Deca Iron ultratriathlon held in Lonata del Garda, Italy, and finished the race as winner within 129:33 hours:minutes. Changes in body mass (including body fat and lean body mass, foot volume, total body water, and laboratory measurements were assessed. Food and fluid intake during rest and competing were recorded, and energy and fluid turnovers were estimated. During the ten stages, the volume of the feet increased, percentage body fat decreased, creatinine and urea levels increased, hematocrit and hemoglobin values decreased, and plasma [Na+] remained unchanged. The increase in foot volume was significantly and positively related to fluid intake during the stages. The poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. This case report shows that the volume of the foot increased during the ten stages, and the increase in volume was significantly and positively related to fluid intake during the stages. Furthermore, the poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. The continuous feet swelling during the race was

  7. Fluid balance and chloride load in the first 24h of ICU admission and its relation with renal replacement therapies through a multicentre, retrospective, case-control study paired by APACHE-II.

    Science.gov (United States)

    González-Castro, A; Ortiz-Lasa, M; Leizaola, O; Salgado, E; Irriguible, T; Sánchez-Satorra, M; Lomas-Fernández, C; Barral-Segade, P; Cordero-Vallejo, M; Rodrigo-Calabia, E; Dierssen-Sotos, T

    2017-05-01

    To analyse the association between water balance during the first 24h of admission to ICU and the variables related to chloride levels (chloride loading, type of fluid administered, hyperchloraemia), with the development of acute kidney injury renal replacement therapy (AKI-RRT) during patients' admission to ICU. Multicentre case-control study. Hospital-based, national, carried out in 6 ICUs. Cases were patients older than 18 years who developed an AKI-RRT. Controls were patients older than 18 years admitted to the same institutions during the study period, who did not develop AKI-RRT during ICU admission. Pairing was done by APACHE-II. An analysis of unconditional logistic regression adjusted for age, sex, APACHE-II and water balance (in evaluating the type of fluid). We analysed the variables of 430 patients: 215 cases and 215 controls. An increase of 10% of the possibility of developing AKI-RRT per 500ml of positive water balance was evident (OR: 1.09 [95% CI: 1.05 to 1.14]; P<.001). The study of mean values of chloride load administered did not show differences between the group of cases and controls (299.35±254.91 vs. 301.67±234.63; P=.92). The water balance in the first 24h of ICU admission relates to the development of IRA-TRR, regardless of chloraemia. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Fluids in metamorphic rocks

    NARCIS (Netherlands)

    Touret, J.L.R.

    2001-01-01

    Basic principles for the study of fluid inclusions in metamorphic rocks are reviewed and illustrated. A major problem relates to the number of inclusions, possibly formed on a wide range of P-T conditions, having also suffered, in most cases, extensive changes after initial trapping. The

  9. Integrated Project Management: A Case Study in Integrating Cost, Schedule, Technical, and Risk Areas

    Science.gov (United States)

    Smith, Greg

    2004-01-01

    This viewgraph presentation describes a case study as a model for integrated project management. The ISS Program Office (ISSPO) developed replacement fluid filtration cartridges in house for the International Space Station (ISS). The presentation includes a step-by-step procedure and organizational charts for how the fluid filtration problem was approached.

  10. Numerical study of fluid motion in bioreactor with two mixers

    Energy Technology Data Exchange (ETDEWEB)

    Zheleva, I., E-mail: izheleva@uni-ruse.bg [Department of Heat Technology, Hydraulics and Ecology, Angel Kanchev University of Rousse, 8 Studentska str., 7017 Rousse (Bulgaria); Lecheva, A., E-mail: alecheva@uni-ruse.bg [Department of Mathematics, Angel Kanchev University of Rousse, 8 Studentska str., 7017 Rousse (Bulgaria)

    2015-10-28

    Numerical study of hydrodynamic laminar behavior of a viscous fluid in bioreactor with multiple mixers is provided in the present paper. The reactor is equipped with two disk impellers. The fluid motion is studied in stream function-vorticity formulation. The calculations are made by a computer program, written in MATLAB. The fluid structure is described and numerical results are graphically presented and commented.

  11. Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

    Science.gov (United States)

    Harikrishnan, S. S.; Kotebavi, Vinod

    2016-09-01

    This paper elaborates on the testing of solar heat pipes using different working fluids, fill ratios and tilt angles. Methanol, Acetone and water are used as working fluids, with fill ratios 25%, 50%, 75% and 100%. Experiments were carried out at 600 and 350 inclinations. Heat pipe condenser section is placed inside a water basin containing 200ml of water. The evaporator section is exposed to sunlight where the working fluid gets heated and it becomes vapour and moves towards the condenser section. In the condenser section the heat is given to the water in the basin and the vapour becomes liquid and comes back to the evaporator section due to gravitational force. Two modes of experiments are carried out: 1) using a parabolic collector and 2) using heat pipe with evacuated tubes. On comparative study, optimum fill ratio is been found to be 25% in every case and acetone exhibited slightly more efficiency than methanol and water. As far as the heat pipe orientation is concerned, 600 inclination of the heat pipe showed better performance than 350

  12. Grid studies for the simulation of resolved structures in an Eulerian two-fluid framework

    Energy Technology Data Exchange (ETDEWEB)

    Gauss, Friederike, E-mail: f.gauss@hzdr.de; Lucas, Dirk; Krepper, Eckhard

    2016-08-15

    Highlights: • Elaborated Eulerian two-fluid methods may predict multiphase flow with large differences in interfacial length scales. • A study on the grid requirements of resolved structures in such two-fluid methods is presented. • The two-fluid results are only little dependent on the grid size. • The results justify the resolved treatment of flow structures covering only few grid cells. • A grid-dependent limit between resolved an modeled structures may be established. - Abstract: The influence of the grid size on the rise velocity of a single bubble simulated with an Eulerian two-fluid method is investigated. This study is part of the development of an elaborated Eulerian two-fluid framework, which is able to predict complex flow phenomena as arising in nuclear reactor safety research issues. Such flow phenomena cover a wide range of interfacial length scales. An important aspect of the simulation method is the distinction into small flow structures, which are modeled, and large structures, which are resolved. To investigate the requirements on the numerical grid for the simulation of such resolved structures the velocity of rising gas bubbles is a good example since theoretical values are available. It is well known that the rise velocity of resolved bubbles is clearly underestimated in a one-fluid approach if they span over only few numerical cells. In the present paper it is shown that in the case of the two-fluid model the bubble rise velocity depends only slightly on the grid size. This is explained with the use of models for the gas–liquid interfacial forces. Good approximations of the rise velocity and the bubble shape are obtained with only few grid points per bubble diameter. This result justifies the resolved treatment of flow structures, which cover only few grid cells. Thus, a limit for the distinction into resolved and modeled structures in the two-fluid context may be established.

  13. Study of magnetorheological fluids at high shear rates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaojie; Gordaninejad, Faramarz [University of Nevada, Department of Mechanical Engineering, Reno, NV (United States)

    2006-08-15

    The tunable rheological properties of magnetorheological (MR) materials at high shear rates are studied using a piston-driven flow-mode-type rheometer. The proposed method provides measurement of the apparent viscosity and yield stress of MR fluids for a shear rate range of 50 to 40,000 s{sup -1}. The rheological properties of a commercial MR fluid, as well as a newly developed MR polymeric gel, and a ferrofluid-based MR fluid are investigated. The results for apparent viscosity and dynamic and static shear stresses under different applied magnetic fields are reported. (orig.)

  14. Studying Validity of Single-Fluid Model in Inertial Confinement Fusion

    International Nuclear Information System (INIS)

    Gu Jian-Fa; Fan Zheng-Feng; Dai Zhen-Sheng; Ye Wen-Hua; Pei Wen-Bing; Zhu Shao-Ping

    2014-01-01

    The validity of single-fluid model in inertial confinement fusion simulations is studied by comparing the results of the multi- and single-fluid models. The multi-fluid model includes the effects of collision and interpenetration between fluid species. By simulating the collision of fluid species, steady-state shock propagation into the thin DT gas and expansion of hohlraum Au wall heated by lasers, the results show that the validity of single-fluid model is strongly dependent on the ratio of the characteristic length of the simulated system to the particle mean free path. When the characteristic length L is one order larger than the mean free path λ, the single-fluid model's results are found to be in good agreement with the multi-fluid model's simulations, and the modeling of single-fluid remains valid. If the value of L/λ is lower than 10, the interpenetration between fluid species is significant, and the single-fluid simulations show some unphysical results; while the multi-fluid model can describe well the interpenetration and mix phenomena, and give more reasonable results. (physics of gases, plasmas, and electric discharges)

  15. Spinodal decomposition in fluid mixtures

    International Nuclear Information System (INIS)

    Kawasaki, Kyozi; Koga, Tsuyoshi

    1993-01-01

    We study the late stage dynamics of spinodal decomposition in binary fluids by the computer simulation of the time-dependent Ginzburg-Landau equation. We obtain a temporary linear growth law of the characteristic length of domains in the late stage. This growth law has been observed in many real experiments of binary fluids and indicates that the domain growth proceeds by the flow caused by the surface tension of interfaces. We also find that the dynamical scaling law is satisfied in this hydrodynamic domain growth region. By comparing the scaling functions for fluids with that for the case without hydrodynamic effects, we find that the scaling functions for the two systems are different. (author)

  16. Fluid inclusions study in thermal gradient wells, Nevado del Ruiz Volcano

    International Nuclear Information System (INIS)

    Uruena Suarez, Cindy L; Zuluaga, Carlos A; Molano, Juan Carlos

    2012-01-01

    A fluid inclusions study in the Nevado del Ruiz volcano hydrothermal system allowed to characterize fluids involved in the evolution of the geothermal system. Fluid inclusions hosted in quartz, plagioclase and carbonate from samples of the deepest parts of three thermal gradient wells were analyzed to understand fluid-rock interaction. Fluid inclusions hosted in carbonate veins with coloform microestructure represent hydrothermal fluids with temperatures higher than 250 Celsius degrade. This interpretation is supported by microprobe and cathodoluminescence analysis that also indicate a hydrothermal origin for the veins. Fluid inclusions hosted in quartz (mylonite) were originated by metamorphic fluids and fluid inclusions hosted in plagioclase (andesitic lavas) are considered to be originated from magmatic fluids (H 2 O + CO 2 system).

  17. Imaging fluid/solid interactions in hydrocarbon reservoir rocks.

    Science.gov (United States)

    Uwins, P J; Baker, J C; Mackinnon, I D

    1993-08-01

    The environmental scanning electron microscope (ESEM) has been used to image liquid hydrocarbons in sandstones and oil shales. Additionally, the fluid sensitivity of selected clay minerals in hydrocarbon reservoirs was assessed via three case studies: HCl acid sensitivity of authigenic chlorite in sandstone reservoirs, freshwater sensitivity of authigenic illite/smectite in sandstone reservoirs, and bleach sensitivity of a volcanic reservoir containing abundant secondary chlorite/corrensite. The results showed the suitability of using ESEM for imaging liquid hydrocarbon films in hydrocarbon reservoirs and the importance of simulating in situ fluid-rock interactions for hydrocarbon production programmes. In each case, results of the ESEM studies greatly enhanced prediction of reservoir/borehole reactions and, in some cases, contradicted conventional wisdom regarding the outcome of potential engineering solutions.

  18. Pressure–Temperature–Fluid Constraints for the Poona Emerald Deposits, Western Australia: Fluid Inclusion and Stable Isotope Studies

    Directory of Open Access Journals (Sweden)

    Dan Marshall

    2016-12-01

    Full Text Available Emerald from the deposits at Poona shows micrometre-scale chemical, optical, and cathodoluminescence zonation. This zonation, combined with fluid inclusion and isotope studies, indicates early emerald precipitation from a single-phase saline fluid of approximately 12 weight percent NaCl equivalent, over the temperature range of 335–525 °C and pressures ranging from 70 to 400 MPa. The large range in pressure and temperature likely reflects some post entrapment changes and re-equilibration of oxygen isotopes. Secondary emerald-hosted fluid inclusions indicate subsequent emerald precipitation from higher salinity fluids. Likewise, the δ18O-δD of channel fluids extracted from Poona emerald is consistent with multiple origins yielding both igneous and metamorphic signatures. The combined multiple generations of emerald precipitation, different fluid compositions, and the presence of both metamorphic and igneous fluids trapped in emerald, likely indicate a protracted history of emerald precipitation at Poona conforming to both an igneous and a metamorphic origin at various times during regional lower amphibolite to greenschist facies metamorphism over the period ~2710–2660 Ma.

  19. Fluid-structure coupling for an oscillating hydrofoil

    Science.gov (United States)

    Münch, C.; Ausoni, P.; Braun, O.; Farhat, M.; Avellan, F.

    2010-08-01

    Fluid-structure investigations in hydraulic machines using coupled simulations are particularly time-consuming. In this study, an alternative method is presented that linearizes the hydrodynamic load of a rigid, oscillating hydrofoil. The hydrofoil, which is surrounded by incompressible, turbulent flow, is modeled with forced and free pitching motions, where the mean incidence angle is 0° with a maximum angle amplitude of 2°. Unsteady simulations of the flow, performed with ANSYS CFX, are presented and validated with experiments which were carried out in the EPFL High-Speed Cavitation Tunnel. First, forced motion is investigated for reduced frequencies ranging from 0.02 to 100. The hydrodynamic load is modeled as a simple combination of inertia, damping and stiffness effects. As expected, the potential flow analysis showed the added moment of inertia is constant, while the fluid damping and the fluid stiffness coefficients depend on the reduced frequency of the oscillation motion. Behavioral patterns were observed and two cases were identified depending on if vortices did or did not develop in the hydrofoil wake. Using the coefficients identified in the forced motion case, the time history of the profile incidence is then predicted analytically for the free motion case and excellent agreement is found for the results from coupled fluid-structure simulations. The model is validated and may be extended to more complex cases, such as blade grids in hydraulic machinery.

  20. Use of Facebook in Teaching: A Case Study of a Fluid Mechanics Course

    Science.gov (United States)

    Mandavgane, Sachin A.

    2016-01-01

    Fluid mechanics (FM) is a core course of the chemical, mechanical, civil, and aerospace engineering programs. Students have both theory and practical classes in FM. The general expectation is that students should be able to demonstrate the fundamentals learnt in theory and get hands-on experience during the lab course. In this regard, students…

  1. EXPERIMENTAL STUDY OF MAGNETIC FLUID SEAL

    Directory of Open Access Journals (Sweden)

    V. G. Bashtovoi

    2006-01-01

    Full Text Available Dependences of critical pressure drop, being held by magnetic fluid seal, on time in a static state and shaft rotation velocity in dynamics have been experimentally determined. The significant influence of particles’ redistribution in magnetic fluid on static parameters of magnetic fluid seal has been established.

  2. Analytical and Numerical Studies of Several Fluid Mechanical Problems

    Science.gov (United States)

    Kong, D. L.

    2014-03-01

    In this thesis, three parts, each with several chapters, are respectively devoted to hydrostatic, viscous, and inertial fluids theories and applications. Involved topics include planetary, biological fluid systems, and high performance computing technology. In the hydrostatics part, the classical Maclaurin spheroids theory is generalized, for the first time, to a more realistic multi-layer model, establishing geometries of both the outer surface and the interfaces. For one of its astrophysical applications, the theory explicitly predicts physical shapes of surface and core-mantle-boundary for layered terrestrial planets, which enables the studies of some gravity problems, and the direct numerical simulations of dynamo flows in rotating planetary cores. As another application of the figure theory, the zonal flow in the deep atmosphere of Jupiter is investigated for a better understanding of the Jovian gravity field. An upper bound of gravity field distortions, especially in higher-order zonal gravitational coefficients, induced by deep zonal winds is estimated firstly. The oblate spheroidal shape of an undistorted Jupiter resulting from its fast solid body rotation is fully taken into account, which marks the most significant improvement from previous approximation based Jovian wind theories. High viscosity flows, for example Stokes flows, occur in a lot of processes involving low-speed motions in fluids. Microorganism swimming is such a typical case. A fully three dimensional analytic solution of incompressible Stokes equation is derived in the exterior domain of an arbitrarily translating and rotating prolate spheroid, which models a large family of microorganisms such as cocci bacteria. The solution is then applied to the magnetotactic bacteria swimming problem, and good consistency has been found between theoretical predictions and laboratory observations of the moving patterns of such bacteria under magnetic fields. In the analysis of dynamics of planetary

  3. Free Surface Waves And Interacting Bouncing Droplets: A Parametric Resonance Case Study

    KAUST Repository

    Borja, Francisco J.

    2013-01-01

    Parametric resonance is a particular type of resonance in which a parameter in a system changes with time. A particularly interesting case is when the parameter changes in a periodic way, which can lead to very intricate behavior. This di↵ers from periodic forcing in that solutions are not necessarily periodic. A system in which parametric resonance is realized is when a fluid bath is shaken periodically, which leads to an e↵ective time dependent gravitational force. This system will be used to study the onset of surface waves in a bath with non-uniform topography. A linear model for the surface waves is derived from the Euler equations in the limit of shallow waves, which includes the geometry of the bottom and surface tension. Experiments are performed to compare with the proposed model and good qualitative agreement is found. Another experiment which relies on a shaking fluid bath is that of bouncing fluid droplets. In the case of two droplets the shaking allows for a larger bouncing droplet to attract a smaller moving droplet in a way that creates a bound system. This bound system is studied and shows some analogous properties to quantum systems, so a quantum mechanical model for a two dimensional atom is studied, as well as a proposed model for the droplet-wave system in terms of equations of fluid mechanics.

  4. Free Surface Waves And Interacting Bouncing Droplets: A Parametric Resonance Case Study

    KAUST Repository

    Borja, Francisco J.

    2013-07-01

    Parametric resonance is a particular type of resonance in which a parameter in a system changes with time. A particularly interesting case is when the parameter changes in a periodic way, which can lead to very intricate behavior. This di↵ers from periodic forcing in that solutions are not necessarily periodic. A system in which parametric resonance is realized is when a fluid bath is shaken periodically, which leads to an e↵ective time dependent gravitational force. This system will be used to study the onset of surface waves in a bath with non-uniform topography. A linear model for the surface waves is derived from the Euler equations in the limit of shallow waves, which includes the geometry of the bottom and surface tension. Experiments are performed to compare with the proposed model and good qualitative agreement is found. Another experiment which relies on a shaking fluid bath is that of bouncing fluid droplets. In the case of two droplets the shaking allows for a larger bouncing droplet to attract a smaller moving droplet in a way that creates a bound system. This bound system is studied and shows some analogous properties to quantum systems, so a quantum mechanical model for a two dimensional atom is studied, as well as a proposed model for the droplet-wave system in terms of equations of fluid mechanics.

  5. Lead poisoning due to gunshot bullet in contact with cerebrospinal fluid: case report

    Directory of Open Access Journals (Sweden)

    Paulo Roberto de Madureira

    Full Text Available CONTEXT: Lead poisoning due to retained gunshot bullets is a well-known clinical problem that is fairly frequently described in the literature. The risk factors for this occurrence relate mainly to whether the lead bullet is in contact with the joint fluid or cerebrospinal fluid (CSF. The treatment for these cases entails chelation therapy while symptoms are shown and definitive surgical removal of the bullet as a potential source of lead. The aim of this paper is to describe a clinical case of lead poisoning due to a retained gunshot bullet in contact with CSF. CASE REPORT: A 42-year-old male was hit by gunshot bullets during a holdup, and one of them was retained in the spinal cord. Six years later, he developed intense low back pain and underwent laminectomy. Nine years later, he then underwent arthrodesis on L5-S1, but he developed intense abdominal pain after the surgical procedure. For five years, he was treated with calcium versenate in five-day cycles, with a good response. The chelation therapy cycles showed great efficacy during symptomatic periods, thus reducing the symptoms and signs of poisoning and promoting great amounts of lead excretion, thereby reducing the total lead burden responsible for the symptoms. Fortunately, over the last four years, the symptoms have improved and the urine levels of aminolevulinic acid (ALA have declined, to reach complete normalization. This shows that a healing process is probably taking place on the spinal wound, thereby isolating the bullet fragments from CSF contact.

  6. Proteomic Analysis of Cerebrospinal Fluid in a Fulminant Case of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Jonas Bergquist

    2012-06-01

    Full Text Available Multiple Sclerosis (MS is a chronic disease, but in rare fulminant cases rapid progression may lead to death shortly after diagnosis. Currently there is no diagnostic test to predict disease course. The aim of this study was to identify potential biomarkers/proteins related to rapid progression. We present the case history of a 15-year-old male MS patient. Cerebrospinal fluid (CSF was taken at diagnosis and at the time of rapid progression leading to the patient’s death. Using isobaric tag labeling and nanoflow liquid chromatography in conjunction with matrix assisted laser desorption/ionization time of flight tandem mass spectrometry we quantitatively analyzed the protein content of two CSF samples from the patient with fulminant MS as well as one relapsing-remitting (RR MS patient and one control headache patient, whose CSF analysis was normal. Seventy-eight proteins were identified and seven proteins were found to be more abundant in both fulminant MS samples but not in the RR MS sample compared to the control. These proteins are involved in the immune response, blood coagulation, cell proliferation and cell adhesion. In conclusion, in this pilot study we were able to show differences in the CSF proteome of a rapidly progressing MS patient compared to a more typical clinical form of MS and a control subject.

  7. Proteomic Analysis of Cerebrospinal Fluid in a Fulminant Case of Multiple Sclerosis

    Science.gov (United States)

    Füvesi, Judit; Hanrieder, Jörg; Bencsik, Krisztina; Rajda, Cecilia; Kovács, S. Krisztián; Kaizer, László; Beniczky, Sándor; Vécsei, László; Bergquist, Jonas

    2012-01-01

    Multiple Sclerosis (MS) is a chronic disease, but in rare fulminant cases rapid progression may lead to death shortly after diagnosis. Currently there is no diagnostic test to predict disease course. The aim of this study was to identify potential biomarkers/proteins related to rapid progression. We present the case history of a 15-year-old male MS patient. Cerebrospinal fluid (CSF) was taken at diagnosis and at the time of rapid progression leading to the patient’s death. Using isobaric tag labeling and nanoflow liquid chromatography in conjunction with matrix assisted laser desorption/ionization time of flight tandem mass spectrometry we quantitatively analyzed the protein content of two CSF samples from the patient with fulminant MS as well as one relapsing-remitting (RR) MS patient and one control headache patient, whose CSF analysis was normal. Seventy-eight proteins were identified and seven proteins were found to be more abundant in both fulminant MS samples but not in the RR MS sample compared to the control. These proteins are involved in the immune response, blood coagulation, cell proliferation and cell adhesion. In conclusion, in this pilot study we were able to show differences in the CSF proteome of a rapidly progressing MS patient compared to a more typical clinical form of MS and a control subject. PMID:22837721

  8. Fluid injection and induced seismicity

    Science.gov (United States)

    Kendall, Michael; Verdon, James

    2016-04-01

    The link between fluid injection, or extraction, and induced seismicity has been observed in reservoirs for many decades. In fact spatial mapping of low magnitude events is routinely used to estimate a stimulated reservoir volume. However, the link between subsurface fluid injection and larger felt seismicity is less clear and has attracted recent interest with a dramatic increase in earthquakes associated with the disposal of oilfield waste fluids. In a few cases, hydraulic fracturing has also been linked to induced seismicity. Much can be learned from past case-studies of induced seismicity so that we can better understand the risks posed. Here we examine 12 case examples and consider in particular controls on maximum event size, lateral event distributions, and event depths. Our results suggest that injection volume is a better control on maximum magnitude than past, natural seismicity in a region. This might, however, simply reflect the lack of baseline monitoring and/or long-term seismic records in certain regions. To address this in the UK, the British Geological Survey is leading the deployment of monitoring arrays in prospective shale gas areas in Lancashire and Yorkshire. In most cases, seismicity is generally located in close vicinity to the injection site. However, in some cases, the nearest events are up to 5km from the injection point. This gives an indication of the minimum radius of influence of such fluid injection projects. The most distant events are never more than 20km from the injection point, perhaps implying a maximum radius of influence. Some events are located in the target reservoir, but most occur below the injection depth. In fact, most events lie in the crystalline basement underlying the sedimentary rocks. This suggests that induced seismicity may not pose a leakage risk for fluid migration back to the surface, as it does not impact caprock integrity. A useful application for microseismic data is to try and forecast induced seismicity

  9. Hydrothermal Fluid evolution in the Dalli porphyry Cu-Au Deposit: Fluid Inclusion microthermometry studies

    Directory of Open Access Journals (Sweden)

    Alireza Zarasvandi

    2015-10-01

    Full Text Available Introduction A wide variety of world-class porphyry Cu deposits occur in the Urumieh-Dohktar magmatic arc (UDMA of Iran.The arc is composed of calc-alkaline granitoid rocks, and the ore-hosting porphyry intrusions are dominantly granodiorite to quartz-monzonite (Zarasvandi et al., 2015. It is believed that faults played an important role in the emplacement of intrusions and subsequentporphyry-copper type mineralization (Shahabpour, 1999. Three main centers host the porphyry copper mineralization in the UDMA: (1 Ardestan-SarCheshmeh-Kharestan zone, (2 Saveh-Ardestan district; in the central parts of the UDMA, hosting the Dalli porphyry Cu-Au deposit, and (3 Takab-Mianeh-Qharahdagh-Sabalan zone. Mineralized porphyry coppersystems in the UDMA are restricted to Oligocene to Mioceneintrusions and show potassic, sericitic, argillic, propylitic and locally skarn alteration (Zarasvandi et al., 2005; Zarasvandi et al., 2015. In the Dalli porphyry deposit, four hydrothermal alteration zones, includingpotassic, sericitic, propylitic, and argillic types have been described in the two discrete mineralized areas, namely, northern and southern stocks. Hypogenemineralization includes chalcopyrite, pyrite, and magnetite, with minor occurrences of bornite.Supergene activity has produced gossan, oxidized minerals and enrichment zones. The supergene enrichment zone contains chalcocite and covellite with a 10-20 m thickness. Mineralization in the northern stock is mainly composed of pyrite and chalcopyrite. The aim of this study is the investigation and classification of hydrothermal veins and the constraining of physicochemical compositions of ore-forming fluids using systematic investigation of fluid inclusions. Materials and methods Twenty samples were collected from drill holes. Thin and polished sections were prepared from hydrothermal veins of thepotassic, sericitic and propylitic alteration zones. Samples used for fluid inclusion measurements were collected

  10. Dynamic analysis of structures with solid-fluid interaction

    International Nuclear Information System (INIS)

    Nahavandi, A.N.; Pedrido, R.R.; Cloud, R.L.

    1977-01-01

    This study develops a finite element model for interaction between an elastic solid and fluid medium (flow-induced vibrations in nuclear reactor components). Plane triangular finite elements have been used separately for fluid, solid, and solid-fluid continuua and the equivalent mass, damping, and stiffness matrices and interaction load arrays for all elements are derived and assembled into global matrices. The global matrix differential equation of motion developed is solved in time to obtain the pressure and velocity distributions in the fluid, as well as the displacements in the solid. Two independent computer programs are used to obtain the dynamic solution. The first program is a finite element program developed for solid-fluid interaction studies. This program uses the modal superposition technique in which the eigenvalues and eigenvectors for the system are found and used to uncouple the equations. This approach allows an analytic solution in each integration time step. The second program is WECAN finite element program in which a new element library subroutine for solid-fluid interaction was incorporated. This program can employ a NASTRAN direct integration scheme based on a central difference formula for the acceleration and velocity terms and an implicit representation of the displacement term. This reduces the problem to a matrix equation whose right hand side is updated in every time step and is solved by a variation of the Gaussian elimination method known as the wave front technique. Results have been obtained for the case of water, between two flat elastic parallel plates, initially at rest and accelerated suddenly by applying a step pressure. The results obtained from the above-mentioned two independent finite element programs are in full agreement. This verification provides the confidence needed to initiate parametric studies. Both rigid wall (no solid-fluid interaction) and flexible wall (including solid-fluid interaction) cases were examined

  11. Numerical modelling of fluid-rock interactions: Lessons learnt from carbonate rocks diagenesis studies

    Science.gov (United States)

    Nader, Fadi; Bachaud, Pierre; Michel, Anthony

    2015-04-01

    Quantitative assessment of fluid-rock interactions and their impact on carbonate host-rocks has recently become a very attractive research topic within academic and industrial realms. Today, a common operational workflow that aims at predicting the relevant diagenetic processes on the host rocks (i.e. fluid-rock interactions) consists of three main stages: i) constructing a conceptual diagenesis model including inferred preferential fluids pathways; ii) quantifying the resulted diagenetic phases (e.g. depositing cements, dissolved and recrystallized minerals); and iii) numerical modelling of diagenetic processes. Most of the concepts of diagenetic processes operate at the larger, basin-scale, however, the description of the diagenetic phases (products of such processes) and their association with the overall petrophysical evolution of sedimentary rocks remain at reservoir (and even outcrop/ well core) scale. Conceptual models of diagenetic processes are thereafter constructed based on studying surface-exposed rocks and well cores (e.g. petrography, geochemistry, fluid inclusions). We are able to quantify the diagenetic products with various evolving techniques and on varying scales (e.g. point-counting, 2D and 3D image analysis, XRD, micro-CT and pore network models). Geochemical modelling makes use of thermodynamic and kinetic rules as well as data-bases to simulate chemical reactions and fluid-rock interactions. This can be through a 0D model, whereby a certain process is tested (e.g. the likelihood of a certain chemical reaction to operate under specific conditions). Results relate to the fluids and mineral phases involved in the chemical reactions. They could be used as arguments to support or refute proposed outcomes of fluid-rock interactions. Coupling geochemical modelling with transport (reactive transport model; 1D, 2D and 3D) is another possibility, attractive as it provides forward simulations of diagenetic processes and resulting phases. This

  12. A case of radiation pneumonitis with eosinophilia in bronchoalveolar lavage fluid

    International Nuclear Information System (INIS)

    Kawai, Seiko; Baba, Kenji; Tanaka, Hiroyuki; Takahashi, Daisuke; Yagi, Takeo; Hattori, Tsutomu; Yamaguchi, Etsuro

    2008-01-01

    A 78-year-old man was admitted to our hospital for irradiation therapy of non-resectable primary lung squamous cell carcinoma of the right middle lobe (T3N2M0). The Linac irradiation through opposing 2 gates (2 Gy per day and 60 Gy in total) was performed to the affected area including the metastatic right hilar and mediastinal lymphadenopathy. One week after completing the irradiation therapy, fever developed with infiltrates in the area from the right middle lobe to the right lower lobe, which did not necessarily coincide with the irradiated area Antibiotic therapies were not effective. Both the serum lactic dehydrogenase (LDH) level and eosinophil count in the peripheral blood increased. Bronchoalveolar lavage was performed at the right B 8 , and differential cell counts of the lavage fluid were macrophages, 17%; lymphocytes, 60%; neutrophils, 5%; and eosinophils, 18%. No significant organisms were obtained by culture of the lavage fluid. The %VC and D LCO /VA became lower than before the irradiation therapy. Thus, the patient was given a diagnosis of radiation pneumonitis. Treatment with 40 mg/day oral prednisolone was commenced with a stepwise dose-reduction (5 mg every two weeks) until reaching the maintenance dose of 15 mg/day. The serum LDH level and blood eosinophil count recovered promptly to the normal range. The pulmonary infiltrates and the lung functions substantially improved. There have been few reports of radiation pneumonitis in which eosinophil counts increased in peripheral blood and bronchoalveolar lavage fluid after irradiation therapy. In the present case report, the possible mechanisms for the irradiation-induced eosinophilia were also reviewed. (author)

  13. A study of chromosomal aberrations in amniotic fluid cell cultures.

    Science.gov (United States)

    Wolstenholme, J; Crocker, M; Jonasson, J

    1988-06-01

    This paper represents the analysis of 1916 routine amniotic fluid specimens harvested by an in situ fixation technique in a prospective study with regard to cultural chromosome anomalies. Excluding constitutional abnormalities, 2.9 per cent of 19,432 cells analysed showed some form of chromosome anomaly, terminal deletions (57 per cent) and chromatid/chromosome breaks and gaps (18 per cent) being the most frequent, followed by interchange aberrations (13 per cent) and trisomy (5 per cent). No case was found of more than one colony from the same culture showing the same anomaly without it being present in other cultures from the same fluid. The wholly abnormal colonies had a surplus of trisomies and from the mathematical considerations presented one may infer that these are likely to reflect the presence of abnormal cells in the amniotic fluid. Partly abnormal colonies appeared at a frequency that would correspond to virtual absence of selection against chromosomally abnormal cells when cultured in vitro. The aberrations found were similar to those seen as single cell anomalies, except for chromatid breaks and exchanges. The data suggest a basic preferential induction of trisomy for chromosomes 2, 18, 21, and the Y-chromosome. Structural aberrations showed a marked clustering of breakpoints around the centromeres. The frequency of mutant cells was low (1.4 X 10(-3)) before culture was initiated. At harvest, the frequency of abnormal cells was much higher (3 X 10(-2)) corresponding to 3 X 10(-3) mutations per cell per generation accumulating over approximately ten generations in vitro.

  14. Fluids transfer in porous media, the case of carbonates and clay/limestone interfaces. Integrated study of petrophysical, sedimentology and microstructures.The case of two carbonates: the case of two carbonates the Oolithe Blanche from the Paris Basin and the Globigerina Limestone of maltese islands

    International Nuclear Information System (INIS)

    Casteleyn, Lisa

    2011-01-01

    Geological storage is now considered as a technical solution for CO_2 storage and nuclear waste management (for high-level and intermediate-level long-lived radioactive waste). A geological storage is a long term project which implies a particular protocol in order to better determine and to better understand the host rock, especially in terms of transport mechanisms. The geological formations studied are chosen in function of their storage capacity because gas storage or nuclear waste storage do not need the same requirements. In case of CO_2 storage, the host formation must provide good reservoir properties in order to facilitate the injection. Here, the safety of the storage is guaranteed by traps (structural, residual, mineral) and by the presence of a cap rock. Concerning nuclear waste storage, the host must retain at best the potential radioactive fluids and gas leaks, and this is the reason why storage sites are studied within low porous and low permeable formation, like argillite organelles. The work presented in the PhD thesis is related to two storage projects. The first one is focused on the petrophysical study of a potential host for CO_2 storage in the Paris Basin, the 'Oolithe Blanche' carbonate formation. The second project is an analogue study of the sedimentary structure explored in the Meuse/Haute-Marne laboratory. This laboratory is studied by ANDRA to be the first nuclear waste storage in a deep geological formation in France. The analogue was found in maltese archipelagos, which presents almost the same tabular structure as the one observed in the Meuse/Haute-Marne laboratory: limestone/clay/limestone affected by a weak tectonic deformation. In the first part, the Oolithe Blanche Formation study allowed to determine the reservoir properties of the three principals facies of the formation. This study was realized on plugs sampled on quarries in Burgundy (France). Those facies are characterized by different environmental processes and deposit

  15. Metalworking fluid-associated hypersensitivity pneumonitis: a workshop summary.

    Science.gov (United States)

    Kreiss, K; Cox-Ganser, J

    1997-10-01

    A workshop discussing eight clusters of hypersensitivity pneumonitis in the automotive industry among metalworking fluid-exposed workers concluded that a risk exists for this granulomatous lung disease where water-based fluids are used and unusual microbial contaminants predominate. Strong candidates for microbial etiology are nontuberculous mycobacteria and fungi. Cases of hypersensitivity pneumonitis occur among cases with other work-related respiratory symptoms and chest diseases. Reversibility of disease has occurred in many cases with exposure cessation, allowing return to work to jobs without metalworking fluid exposures or, in some situations, to jobs without the same metalworking fluid exposures. Cases have been recognized with metalworking fluid exposures generally less than 0.5 mg/m3. The workshop participants identified knowledge gaps regarding risk factors, exposure-response relationships, intervention efficacy, and natural history, as well as surveillance needs to define the extent of the problem in this industry. In the absence of answers to these questions, guidance for prevention is necessarily limited.

  16. Extended two-fluid model for simulating magneto-rheological fluid flows

    International Nuclear Information System (INIS)

    Shivaram, A C

    2011-01-01

    The current practice of designing magneto-rheological (MR) fluid-based devices is, to a large extent, based on simple phenomenological models like the Bingham model. Though useful for initial force or torque estimation and sizing, these models lack the capability to predict performance degradation due to changes in the particle volume fraction distribution. The present work demonstrates the use of the two-fluid model for predicting the particle volume fraction distribution inside a device in the absence of a field and proposes a novel modeling scheme which can simulate the fluid flow in the presence of a field. This modeling scheme can be used to (a) visualize flow patterns inside a device under various operating conditions, (b) predict the spatial distribution of particles inside a device after multiple operating cycles, (c) assist in estimating the extent of performance degradation due to non-uniform particle distribution and (d) enable testing of various design strategies to mitigate such performance issues using simulations. This is illustrated through numerical examples of a few case studies of typical MR device configurations

  17. Study of blades inclination influence of gate impeller with a non-Newtonian fluid of Bingham

    Directory of Open Access Journals (Sweden)

    Rahmani Lakhdar

    2016-01-01

    Full Text Available A large number of chemical operations, biochemical or petrochemical industry is very depending on the rheological fluids nature. In this work, we study the case of highly viscous of viscoplastic fluids in a classical system of agitation: a cylindrical tank with plate bottom without obstacles agitated by gate impeller agitator. We are interested to the laminar, incompressible and isothermal flows. We devote to a numerical approach carried out using an industrial code CFD Fluent 6.3.26 based on the method of finites volumes discretization of Navier - Stokes equations formulated in variables (U.V.P. The threshold of flow related to the viscoplastic behavior is modeled by a theoretical law of Bingham. The results obtained are used to compare between the five configurations suggested of power consumption. We study the influence of inertia by the variation of Reynolds number.

  18. Computational fluid dynamics (CFD) studies of a miniaturized dissolution system.

    Science.gov (United States)

    Frenning, G; Ahnfelt, E; Sjögren, E; Lennernäs, H

    2017-04-15

    Dissolution testing is an important tool that has applications ranging from fundamental studies of drug-release mechanisms to quality control of the final product. The rate of release of the drug from the delivery system is known to be affected by hydrodynamics. In this study we used computational fluid dynamics to simulate and investigate the hydrodynamics in a novel miniaturized dissolution method for parenteral formulations. The dissolution method is based on a rotating disc system and uses a rotating sample reservoir which is separated from the remaining dissolution medium by a nylon screen. Sample reservoirs of two sizes were investigated (SR6 and SR8) and the hydrodynamic studies were performed at rotation rates of 100, 200 and 400rpm. The overall fluid flow was similar for all investigated cases, with a lateral upward spiraling motion and central downward motion in the form of a vortex to and through the screen. The simulations indicated that the exchange of dissolution medium between the sample reservoir and the remaining release medium was rapid for typical screens, for which almost complete mixing would be expected to occur within less than one minute at 400rpm. The local hydrodynamic conditions in the sample reservoirs depended on their size; SR8 appeared to be relatively more affected than SR6 by the resistance to liquid flow resulting from the screen. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. APPLICATION OF PBL IN THE COURSE FLUID AND ELECTRICAL DRIVE SYSTEMS, CASE STUDY: MANUFACTURING AN AUTOMATED PUNCH MACHINE

    Directory of Open Access Journals (Sweden)

    Ahmad Sedaghat

    2017-01-01

    Full Text Available The PBL unit of fluid and electrical drive systems is taught in final semester of undergraduates in mechanical engineering department of the Australian College of Kuwait (ACK. The recent project on an automated punching machine is discovered more appealing to both students and instructors in triggering new ideas and satisfaction end results. In this case study, the way this PBL unit is coordinated and facilitated is explained. Two examples of student works are presented. The aim is to expose the students to real world engineering problems but in a satisfying manner. Similar to real life problems for engineers, restrictions are applied for the students on costs, availability of ACK facilities, and application of automation tools. Students are directly engaged by using technical standards on punching heads and dies, standard tensile testing of plates, and so on. Arduino microprocessor programming, an open-source hardware and software electronic platform, and electro-pneumatic devices are adopted for developing the automated punching machine. The goal of the PBL course is to acquaint students learning based on the concepts of team working, engineering design, professional manufacturing, and sequential testing of the end product. It is found that students achieved their best and developed new skills in this PBL unit as reflected in their portfolios.

  20. A case of pathological drainage and aberrant cerebrospinal fluid pathway demonstrated by using radioisotopic imaging

    International Nuclear Information System (INIS)

    Tondeur, M.; Oulad Ben Taibb, N.

    2007-01-01

    We describe the case of a woman with ventriculo-peritoneal drainage who presented, following bilateral breast reparative surgery, an abnormally abundant liquid production in one of the surgical drains. This production was related to unknown rupture of the thoracic portion of the ventriculo-peritoneal drain, having led to the direct passage of the cerebrospinal fluid into the surgical drain. Rupture of the thoracic portion of the ventriculo-peritoneal drain was demonstrated by X-ray. However, the pathway of the cerebrospinal fluid and its direct passage throughout the surgical drain were demonstrated by isotopic procedure. Based upon this observation, we briefly describe and discuss the principle, technical characteristics, advantages and disadvantages of isotopic procedures, allowing to demonstrate permeability of ventricular derivations. (authors)

  1. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis.

    Science.gov (United States)

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects' age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  2. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis

    Directory of Open Access Journals (Sweden)

    Hamed Aminiahidashti

    2014-08-01

    Full Text Available Introduction: Spontaneous bacterial peritonitis (SBP as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Methods: Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. Results: The present project was performed in 80 cirrhotic patients with ascites (52.5 female. The mean of the subjects’ age was 56.25±12.21 years (35-81. Laboratory findings revealed SBP in 23 (29% cases. Fifty nine (73% cases had transparent ascites fluid appearance of whom 17 (29% ones suffered from SBP. From 21 (26% cases with opaque ascites appearance, 15 (71% had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55 and 87.50% (95% Cl: 75.3-94.14, respectively. Conclusion: It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  3. [Significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate monitoring for management of fetal distress during labor].

    Science.gov (United States)

    Zhao, S; Ai, L; Zhang, H

    2000-01-01

    To discuss the significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate (FHR) monitoring for management of fetal distress during labor. 136 cases with frequent variable deceleration (VD) and meconium stained amniotic fluid during labor were divided into two groups: the study group (68 cases) and the control group (68 cases). The former were treated by amnioinfusion and amniotic fluid exchange, while oxygen inhalation, change of body position, and intravenous infusion for the control group. In the study group, VD disappeared or relieved in 62 cases obviously, and the efficacy rate reached 91.2% (62/68). 48 cases with II degree meconium stained amniotic fluid were treated by amniotic fluid exchange, amniotic fluid became clear or turned to I degree stained in 39 cases. In the control group, VD relieved in 20 cases, the efficacy rate was 19.4%, significantly lower than that of the study group (P 0.05). Amnioinfusion and AF exchange during labor are one of the effective treatment methods for fetal distress and prevention for MAS.

  4. Endoscopic Management of Pancreatic Fluid Collections in Children.

    Science.gov (United States)

    Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar

    2017-07-15

    The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.

  5. Studies of strength and rheological properties of clay-cement fluids

    Energy Technology Data Exchange (ETDEWEB)

    Salamatov, M A

    1979-01-01

    New principles are substantiated and formulated for studying the strength and elastic-plastic-viscous properties of clay-cement plugging fluids on series manufactured displacement instruments. A technique is presented and results are cited from studies of clay-cement plugging fluids of different composition at different stages of stabilization.

  6. Hazards of organic working fluids

    International Nuclear Information System (INIS)

    Silberstein, S.

    1977-08-01

    We present several brief reviews on working fluids proposed for use in organic Rankine and bi-phase bottoming cycles. There are several general problems with many organic working fluids: flammability, toxicity, and a tendency to leak through seals. Besides, two of the proposed working fluids are to be used at temperatures above the manufacturer's maximum recommended temperature, and one is to be used in a way different from its customary usage. It may, in some cases, be more profitable to first seek alternative working fluids before committing large amounts of time and money to research projects on unsafe working fluids

  7. Numerical study of shear thickening fluid with discrete particles embedded in a base fluid

    Directory of Open Access Journals (Sweden)

    W Zhu

    2016-09-01

    Full Text Available The Shear Thickening Fluid (STF is a dilatant material, which displays non-Newtonian characteristics in its unique ability to transit from a low viscosity fluid to a high viscosity fluid. The research performed investigates the STF behavior by modeling and simulation of the interaction between the base flow and embedded rigid particles when subjected to shear stress. The model considered the Lagrangian description of the rigid particles and the Eulerian description of fluid flow. The numerical analysis investigated key parameters such as applied flow acceleration, particle distribution and arrangement, volume concentration of particles, particle size, shape and their behavior in a Newtonian and non-Newtonian fluid base. The fluid-particle interaction model showed that the arrangement, size, shape and volume concentration of the particles had a significant effect on the behavior of the STF. Although non-conclusive, the addition of particles in non-Newtonian fluids showed a promising trend of improved shear thickening effects at high shear strain rates.

  8. Analytical and experimental study of two concentric cylinders coupled by a fluid gap

    International Nuclear Information System (INIS)

    Mulcahy, T.M.; Turula, P.; Chung, H.; Jendrzejczyk, J.A.

    1975-04-01

    A breeder reactor vessel is a substantial steel cylinder which is partially protected from the nuclear reaction temperature by a relatively thin concentric shell separated from the vessel by a narrow fluid-filled gap. An experimental and analytical study of the vibration of a model of such a shell used in the Fast Test Reactor is described. The analytical work consists first using a free vibration solution of the shell in vacuum as a basis for extrapolating vibration behavior for the same shell with a fluid gap. Then a direct finite element solution is found for the actual problem--the shell and the fluid coupling it to the rigid outer container. All the finite element computations were carried out using the NASTRAN program. The experimental setup consisted of a steel sheet rolled and welded into a cylinder, free at the top edge and at the bottom soldered to a disc which in turn was bolted to a heavy base plate. The fluid gap was provided by using a thick concrete shell as the outer cylinder. A series of these cylinders was used to provide several sizes of annular gap. The case of the steel shell alone, without fluid, was also considered. The steel cylinder was vibrated by an electromagnetic exciter using both harmonic loading and random loading functions. In general, correspondence of experimental and analytical results is within acceptable limits; however, several vibration modes corresponding to solutions with low circumferential wave numbers were not detected experimentally. Response analysis performed to compare the response amplitude at various modes indicates that the intensity at the modes in question is very low. (U.S.)

  9. Hamiltonian formalism for perfect fluids in general relativity

    International Nuclear Information System (INIS)

    Demaret, J.; Moncrief, V.

    1980-01-01

    Schutz's Hamiltonian theory of a relativistic perfect fluid, based on the velocity-potential version of classical perfect fluid hydrodynamics as formulated by Seliger and Whitham, is used to derive, in the framework of the Arnowitt, Deser, and Misner (ADM) method, a general partially reduced Hamiltonian for relativistic systems filled with a perfect fluid. The time coordinate is chosen, as in Lund's treatment of collapsing balls of dust, as minus the only velocity potential different from zero in the case of an irrotational and isentropic fluid. A ''semi-Dirac'' method can be applied to quantize astrophysical and cosmological models in the framework of this partially reduced formalism. If one chooses Taub's adapted comoving coordinate system, it is possible to derive a fully reduced ADM Hamiltonian, which is equal to minus the total baryon number of the fluid, generalizing a result previously obtained by Moncrief in the more particular framework of Taub's variational principle, valid for self-gravitating barotropic relativistic perfect fluids. An unconstrained Hamiltonian density is then explicitly derived for a fluid obeying the equation of state p=(gamma-1)rho (1 < or = γ < or = 2), which can adequately describe the phases of very high density attained in a catastrophic collapse or during the early stages of the Universe. This Hamiltonian density, shown to be equivalent to Moncrief's in the particular case of an isentropic fluid, can be simplified for fluid-filled class-A diagonal Bianchi-type cosmological models and appears as a suitable starting point for the study of the canonical quantization of these models

  10. Topology optimization of fluid mechanics problems

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Allan

    While topology optimization for solid continuum structures have been studied for about 20 years and for the special case of trusses for many more years, topology optimization of fluid mechanics problems is more recent. Borrvall and Petersson [1] is the seminal reference for topology optimization......D Navier-Stokes equation as well as an example with convection dominated transport in 2D Stokes flow. Using Stokes flow limits the range of applications; nonetheless, the present work gives a proof-of-concept for the application of the method within fluid mechanics problems and it remains...... processing tool. Prior to design manufacturing this allows the engineer to quantify the performance of the computed topology design using standard, credible analysis tools with a body-fitted mesh. [1] Borrvall and Petersson (2003) "Topology optimization of fluids in Stokes flow", Int. J. Num. Meth. Fluids...

  11. Sub-aponeurotic fluid collections in infancy

    International Nuclear Information System (INIS)

    Hopkins, R.E.; Inward, C.; Chambers, T.; Grier, D.

    2002-01-01

    AIM: To describe the radiological features and natural history of sub-aponeurotic fluid collections presenting after the neonatal period. MATERIALS AND METHODS: All cases of sub-aponeurotic scalp fluid collection presenting to the radiology department between June 1996 and June 2000 were reviewed. Note was made of the birth history, the radiographic and ultrasound features and the natural history (including any treatment) of the collection. RESULTS: Seven cases of sub-aponeurotic fluid collections were identified. There were six infants who presented 3·5-18 weeks (mean nine weeks) after delivery, four of whom had had ventouse-assisted delivery. The last case was in a seven-year-old child who presented one month after minor head trauma. Clinical examination revealed non-tender, soft, mobile and fluctuant scalp swellings in all patients. Ultrasound identified sonolucent fluid collections of between 5 and 24 mm depth in the sub-aponeurotic space. No skull fractures were identified. Six patients were treated conservatively and one had fluid aspirated and a compression bandage applied. All cases resolved 2-24 weeks after diagnosis and there were no long-term sequelae. CONCLUSION: Sub-aponeurotic scalp collections presenting after the neonatal period are usually associated with ventouse-assisted delivery ultrasound is useful for diagnosis. The condition is benign and resolution occurs with conservative treatment. Hopkins, R.E. et al. (2002)

  12. Sub-aponeurotic fluid collections in infancy

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, R.E.; Inward, C.; Chambers, T.; Grier, D

    2002-02-01

    AIM: To describe the radiological features and natural history of sub-aponeurotic fluid collections presenting after the neonatal period. MATERIALS AND METHODS: All cases of sub-aponeurotic scalp fluid collection presenting to the radiology department between June 1996 and June 2000 were reviewed. Note was made of the birth history, the radiographic and ultrasound features and the natural history (including any treatment) of the collection. RESULTS: Seven cases of sub-aponeurotic fluid collections were identified. There were six infants who presented 3{center_dot}5-18 weeks (mean nine weeks) after delivery, four of whom had had ventouse-assisted delivery. The last case was in a seven-year-old child who presented one month after minor head trauma. Clinical examination revealed non-tender, soft, mobile and fluctuant scalp swellings in all patients. Ultrasound identified sonolucent fluid collections of between 5 and 24 mm depth in the sub-aponeurotic space. No skull fractures were identified. Six patients were treated conservatively and one had fluid aspirated and a compression bandage applied. All cases resolved 2-24 weeks after diagnosis and there were no long-term sequelae. CONCLUSION: Sub-aponeurotic scalp collections presenting after the neonatal period are usually associated with ventouse-assisted delivery ultrasound is useful for diagnosis. The condition is benign and resolution occurs with conservative treatment. Hopkins, R.E. et al. (2002)

  13. Risk Associated With The Decompression Of High Pressure High Temperature Fluids - Study On Black Oil

    DEFF Research Database (Denmark)

    Figueroa, D. C.; Fosbøl, P. L.; Thomsen, K.

    2015-01-01

    Fluids produced from deep underground reservoirs may result in exponential increase in temperature. It is a consequence of adiabatic fluid decompression from the inverse Joule Thomson Effect (JTE). The phenomenon requires analysis in order to avoid any operational risks. This study evaluates...... the JTE upon decompression of black oil in high pressure-high temperature reservoirs. Also the effect caused by the presence of water and brine on the black oil is studied. The final temperature is calculated from the corresponding energy balance at isenthalpic and non-isenthalpic conditions. It is found...... that the final temperature of black oil increases upon adiabatic decompression. In the case of the isenthalpic process at initial conditions of the reservoir, e.g. 150°C and 1000 bars, it is found that the final temperature can increase to 173.7°C. At non-isenthalpic conditions the final temperature increases...

  14. Fluids and the evolution of rock mechanical properties

    International Nuclear Information System (INIS)

    Reuschle, Thierry

    1989-01-01

    This research thesis reports the study of the various phenomena of fluid-solid interaction (mechanical or chemical interaction with fracturing by fluid overpressure, slow crack propagation, and pore deformation by transfer in solution) which may occur in the interaction of fluids with rocks. The author first presents the formalism of slow crack propagation based on the generalisation of the Griffith criterion. The model results are compared with experimental results obtained on four materials (glass, quartz, sandstone, and micrite) by using the double-torsion test. In the second part, the author addresses the issue of pore deformation by transfer in solution: dissolution and crystallisation under stress. The Gibbs chemical potential equation is firstly generalised to the case of a circular pore, and a formalism combining mechanics and thermodynamics is then proposed. A set of simulations highlights important parameters. In the third part, the author addresses the problem of fluid-rock mechanical interaction by studying the mechanical role of fluid pressure in crack initiation and propagation [fr

  15. A Study on Fluid Dispersion after Liquid Filled Missile Impact

    International Nuclear Information System (INIS)

    Shin, Sang Shup; Hahm, Daegi; Choi, In-Kil

    2015-01-01

    In order to fire damage evaluations by fuel included transportation crash, the fire duration should be analyzed that consider the fuel spread range, amount of leaked fuel, and various ignition sources. The water slug impact test performed in Sandia National Laboratory (SNL) in 2002 was representative. The cloud of mist dispersion range of the dyed red water and ejection velocity of water after impact were analyzed using Particle Image Velocimetry (PIV) method and numerical simulation. In this study, the included fluid was modeled by using smooth particle hydrodynamics (SPH) technique. The fluid dispersion range following impact was analyzed by considering the particle velocity and flying distance. The result values obtained through this study were compared to the water slug (WS) test results. And the applicability of an analysis method was verified by comparing the WS test results. The results and methodology obtained through this study can be utilized to damage assessment, fuel spread and fire risk for large infrastructures such as nuclear power plants following an aircraft impact. In this study, the included fluid was modeled by using smooth particle hydrodynamics (SPH) technique; the fluid spread range following an impact was analyzed. The radius of fluid spread on the numerical analysis became conservative than the WS test results. However, the shape of the cloud is similar to the WS test results

  16. A Study on Fluid Dispersion after Liquid Filled Missile Impact

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Shup; Hahm, Daegi; Choi, In-Kil [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In order to fire damage evaluations by fuel included transportation crash, the fire duration should be analyzed that consider the fuel spread range, amount of leaked fuel, and various ignition sources. The water slug impact test performed in Sandia National Laboratory (SNL) in 2002 was representative. The cloud of mist dispersion range of the dyed red water and ejection velocity of water after impact were analyzed using Particle Image Velocimetry (PIV) method and numerical simulation. In this study, the included fluid was modeled by using smooth particle hydrodynamics (SPH) technique. The fluid dispersion range following impact was analyzed by considering the particle velocity and flying distance. The result values obtained through this study were compared to the water slug (WS) test results. And the applicability of an analysis method was verified by comparing the WS test results. The results and methodology obtained through this study can be utilized to damage assessment, fuel spread and fire risk for large infrastructures such as nuclear power plants following an aircraft impact. In this study, the included fluid was modeled by using smooth particle hydrodynamics (SPH) technique; the fluid spread range following an impact was analyzed. The radius of fluid spread on the numerical analysis became conservative than the WS test results. However, the shape of the cloud is similar to the WS test results.

  17. Dipolar fluid-wall systems. Beyond the image potential

    International Nuclear Information System (INIS)

    Boudh-hir, M.E.

    1989-02-01

    The case of dipolar fluid in front of an ideal wall is examined. The surface-fluid system is introduced as a limit case of a binary mixture Using the diagrammatic development, the expansion of the one-particle distribution function is given. 16 refs

  18. Periodontitis-associated septic pulmonary embolism caused by Actinomyces species identified by anaerobic culture of bronchoalveolar lavage fluid: a case report.

    Science.gov (United States)

    Endo, Shun; Mishima, Eikan; Takeuchi, Yoichi; Ohi, Takashi; Ishida, Masatsugu; Yanai, Masaru; Kiyomoto, Hideyasu; Nagasawa, Tasuku; Ito, Sadayoshi

    2015-12-01

    Periodontal disease is a less common but important cause of septic pulmonary embolism (SPE). However, the pathogens causing periodontal disease-associated SPE (PD-SPE) have been poorly understood. Actinomyces species are resident microbiota in the oral cavity. Here we report a case of PD-SPE caused by Actinomyces species, which was identified by anaerobic culture of bronchoalveolar lavage fluid (BAL). A 64-year-old Asian man, complicated with severe chronic periodontitis, was admitted with chest pain and fever. Chest CT revealed multiple bilateral pulmonary nodules located subpleurally. We diagnosed the case as SPE associated with periodontitis. Although blood cultures were negative for the usual 5-day incubation, anaerobic culture of the BAL fluid sample yielded Actinomyces species. Antibacterial therapy alone did not ameliorate the symptoms; however, additional dental treatment, including tooth extraction, promptly did. The patient was discharged 23 days after admission. The 3-month follow-up revealed no recurrence of the symptoms and complete resolution of the lung lesions. This case demonstrated that Actinomyces species can cause PD-SPE. Additionally, clinicians should consider performing appropriate anaerobic culture of BAL fluid to identify the pathogen of SPE, and to ordering dental treatment, if necessary, in addition to antibiotics for the initial management of PD-SPE.

  19. Numerical study of coupled fluid-structure interaction for combustion system

    NARCIS (Netherlands)

    Khatir, Z.; Pozarlik, Artur Krzysztof; Cooper, R.K.; Watterson, J.W.; Kok, Jacobus B.W.

    2007-01-01

    The computation of fluid–structure interaction (FSI) problems requires solving simultaneously the coupled fluid and structure equations. A partitioned approach using a volume spline solution procedure is applied for the coupling of fluid dynamics and structural dynamics codes. For comparative study,

  20. Endoscopic transpterygoidal repair of a large cranial defect with cerebrospinal fluid leak in a patient with extensive osteoradionecrosis of the skull base: case report and technical note.

    Science.gov (United States)

    Brand, Y; Lim, E; Waran, V; Prepageran, N

    2015-12-01

    Endoscopic endonasal techniques have recently become the method of choice in dealing with cerebrospinal fluid leak involving the anterior cranial fossa. However, most surgeons prefer an intracranial approach when leaks involve the middle cranial fossa. This case report illustrates the possibilities of using endoscopic techniques for cerebrospinal fluid leaks involving the middle fossa. A 37-year-old male patient presented with multiple areas of cranial defect with cerebrospinal fluid leak due to osteoradionecrosis following radiation for nasopharyngeal carcinoma 4 years earlier. Clinical examination showed involvement of all cranial nerves except the IInd and XIth nerves on the left side. A prior attempt to repair the cerebrospinal fluid leak with craniotomy was not successful. This case demonstrates the successful endoscopic repair of a large cranial defect with cerebrospinal fluid leak.

  1. Evolution of supercritical fluid in deeply subducted continental crust: a case study of composite granite-quartz veins in the Sulu belt, China

    Science.gov (United States)

    Wang, S.; Wang, L.; Brown, M.

    2016-12-01

    Although fluid plays a key role in element transport and rock strength during subduction to and exhumation from ultrahigh pressure (UHP) metamorphic conditions, the source of supercritical fluid at P above the second critical endpoints (SCE) and the subsequent evolution are not well constrained. To provide insight into the evolution of supercritical fluid in continental subduction zones, we undertook an integrated study of composite granite-quartz veins in retrogressed and migmatitic UHP eclogite at General's Hill, N of Qingdao, in the central Sulu belt. The composite veins are irregularly distributed in the eclogite, which occurs as blocks within gneiss. The granite component is enriched in large ion lithophile elements and light rare earth elements but depleted in high field strength elements and heavy rare earth elements, indicating crystallization from a melt phase of crustal origin. Additionally, the granite contains high modal phengite (22-30 vol%) and clinozoisite/epidote (3-10 vol%), implying precipitation from a H2O-rich silicate melt. By contrast, the quartz component is dominated by SiO2 (99.10 wt%), and contains low total rare earth elements (ΣREE = 0.46 ppm), indicating precipitation from an aqueous fluid. The crystallization age of the composite veins is 221 ± 2 Ma, which is younger than the UHP metamorphism in the Sulu belt at ca 230 Ma, consistent with formation during exhumation. Initial 176Hf/177Hf ratios and δ18O values of metamorphic zircons from the composite veins, and Sr-Nd isotope compositions of the granites all lie between values for eclogite and gneiss, indicating a mixed source. Accordingly, we propose that a supercritical fluid generated from the gneiss and the included blocks of eclogite at P-T conditions above the SCE for both compositions became trapped in the eclogite during exhumation. At P below the SCE for the hydrous granite system, the mixed supercritical fluid separated into immiscible aqueous melt and aqueous fluid and

  2. A study on the relationship between radiologic classification and glycosaminoglycan analysis of cystic fluids in oral region

    Energy Technology Data Exchange (ETDEWEB)

    Park, In Woo; You, Dong Soo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1993-08-15

    This study was designed to evaluate the correlationship between radiologic classifications of cysts in oral region and glycosaminoglycan analysis of cystic fluids using cellulose acetate electrophoresis. The materials for this study consisted of 37 cases-8 periapical cysts, 10 dentigerous cysts, 10 primordial cysts, 2 residual cyst, 3 incisive canal cysts, 2 post-operative maxillary cysts, 1 mucocele on maxillary sinus, and 1 unicystic ameloblastoma-diagnosed as cystic lesions radiologically. The obtained results were as follows: 1. At the stepwise discriminant analysis, four variables-low mobility material, hiparin, hyaluronic acid, and dermatan sulfate- were used to define diagnostic model for the odontogenic cyst. The model produced a seventeenths of 100% and a specificity of 85%. 2. The intensities of heparin and chondroitin-4-sulfate were greater in dentigerous cyst than periapical cyst (p<0.05). 3. It showed no statistically significant difference in glycosaminoglycan of the cystic fluids between dentigerous cyst and primordial cyst (p<0.05). 4. On the fluids of the cysts originated from maxillary sinus, there were especially high intensities of heparin and dermatan sulfate, and low intensity of chondroitin-4-sulfate. 5. On the fluids of unicystic ameloblastoma, there were high intensity of dermatan sulfate and low intensity of chondroitin-4-sulfate.

  3. A study on the relationship between radiologic classification and glycosaminoglycan analysis of cystic fluids in oral region

    International Nuclear Information System (INIS)

    Park, In Woo; You, Dong Soo

    1993-01-01

    This study was designed to evaluate the correlationship between radiologic classifications of cysts in oral region and glycosaminoglycan analysis of cystic fluids using cellulose acetate electrophoresis. The materials for this study consisted of 37 cases-8 periapical cysts, 10 dentigerous cysts, 10 primordial cysts, 2 residual cyst, 3 incisive canal cysts, 2 post-operative maxillary cysts, 1 mucocele on maxillary sinus, and 1 unicystic ameloblastoma-diagnosed as cystic lesions radiologically. The obtained results were as follows: 1. At the stepwise discriminant analysis, four variables-low mobility material, hiparin, hyaluronic acid, and dermatan sulfate- were used to define diagnostic model for the odontogenic cyst. The model produced a seventeenths of 100% and a specificity of 85%. 2. The intensities of heparin and chondroitin-4-sulfate were greater in dentigerous cyst than periapical cyst (p<0.05). 3. It showed no statistically significant difference in glycosaminoglycan of the cystic fluids between dentigerous cyst and primordial cyst (p<0.05). 4. On the fluids of the cysts originated from maxillary sinus, there were especially high intensities of heparin and dermatan sulfate, and low intensity of chondroitin-4-sulfate. 5. On the fluids of unicystic ameloblastoma, there were high intensity of dermatan sulfate and low intensity of chondroitin-4-sulfate.

  4. Study on magnetic fluid optical fiber devices for optical logic operations by characteristics of superparamagnetic nanoparticles and magnetic fluids

    International Nuclear Information System (INIS)

    Chieh, J. J.; Hong, C. Y.; Yang, S. Y.; Horng, H. E.; Yang, H. C.

    2010-01-01

    We propose two optical fiber-based schemes using two magnetic fluid optical fiber modulators in series or in parallel for optical logic signal processing and operation. Here, each magnetic fluid optical fiber modulator consists of a bare multimode fiber surrounded by magnetic fluid in which the refractive index is adjustable by applying external magnetic fields amplifying the input electrical signal to vary the transmission intensity of the optical fiber-based scheme. The physical mechanisms for the performances of the magnetic fluid optical fiber devices, such as the transmission loss related to Boolean number of the logic operation as well as the dynamic response, are studied by the characteristics of superparamagnetic nanoparticles and magnetic fluids. For example, in the dynamic response composed of the retarding and response sub-procedures except the response times of the actuation coil, the theoretical evaluation of the retarding time variation with cladding magnetic fluids length has good agreement with the experimental results.

  5. Dispersion of axially symmetric waves in fluid-filled cylindrical shells

    DEFF Research Database (Denmark)

    Bao, X.L.; Überall, H.; Raju, P. K.

    2000-01-01

    Acoustic waves normally incident on an elastic cylindrical shell can cause the excitation of circumferential elastic waves on the shell. These shells may be empty and fluid immersed, or fluid filled in an ambient medium of air, or doubly fluid loaded inside and out. Circumferential waves...... on such shells have been investigated for the case of aluminum shells, and their phase-velocity dispersion curves have been obtained for double fluid loading [Bao, Raju, and Überall, J. Acoust. Soc. Am. 105, 2704 (1999)]. Similar results were obtained for empty or fluid-filled brass shells [Kumar, Acustica 27......, 317 (1972)]. We have extended the work of Kumar to the case of fluid-filled aluminum shells and steel shells imbedded in air. These cases demonstrate the existence of circumferential waves traveling in the filler fluid, exhibiting a certain simplicity of the dispersion curves of these waves...

  6. Disappearing fluid?

    International Nuclear Information System (INIS)

    Graney, K.; Chu, J.; Lin, P.C.

    2002-01-01

    Full text: A 78-year old male in end stage renal failure (ESRF) with a background of NIDDM retinopathy, nephropathy, and undergoing continuous ambulatory peritoneal dialysis (CAPD) presented with anorexia, clinically unwell, decreased mobility and right scrotal swelling. There was no difficulty during CAPD exchange except there was a positive fluid balance Peritoneal dialysates remained clear A CAPD peritoneal study was requested. 100Mbq 99mTc Sulphur Colloid was injected into a standard dialysate bag containing dialysate. Anterior dynamic images were acquired over the abdomen pelvis while the dialysate was infused Static images with anatomical markers were performed 20 mins post infusion, before and after patient ambulation and then after drainage. The study demonstrated communication between the peritoneal cavity and the right scrotal sac. Patient underwent right inguinal herniaplasty with a marlex mesh. A repeat CAPD flow study was performed as follow up and no abnormal connection between the peritoneal cavity and the right scrotal sac was demonstrated post operatively. This case study shows that CAPD flow studies can be undertaken as a simple, minimally invasive method to evaluate abnormal peritoneal fluid flow dynamics in patients undergoing CAPD, and have an impact on dialysis management. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Body drop into a fluid tank and dynamic loads calculation

    Directory of Open Access Journals (Sweden)

    Komarov Aleksandr Andreevich

    2014-05-01

    Full Text Available The theory of a body striking a fluid began intensively developing due to the tasks of hydroplanes landing. For the recent years the study of a stroke and submersion of bodies into fluid became even more current. We face them in the process of strength calculation of ship hulls and other structures in modern technology. These tasks solution represents great mathematical difficulty even in case of the mentioned simplifications. These difficulties emerge due to the unsteady character of fluid motion in case of body submersion, and also jet and spray phenomena, which lead to discontinuous motions. On the basis of G.V. Logvinovich’s concept the problem of loads determination with consideration for air gap is solved for both a body and reservoir enclosing structures when a body falls into a fluid. Numerical method is based on the decay of an arbitrary discontinuity.

  8. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation.

    Science.gov (United States)

    Oriol, Isabel; Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid.

  9. Cerebrospinal fluid otorrhea and recurrent bacterial meningitis in a pediatric case with Mondini dysplasia.

    Science.gov (United States)

    Işeri, Mete; Uçar, Selçuk; Derin, Serhan; Ustündağ, Emre

    2013-01-01

    Mondini dysplasia is a congenital malformation of the inner ear, which is characterized by a short and large cochlear canal of 1.5 turn rather than 2.5 turns and an apical region with cystic dilatation. Patients present with congenital deafness, when both cochlea are affected. Unilateral disease may cause recurrent meningitis, otorrhea or rhinorrhea. In this article, we report a three-year-old pediatric case with a history of meningitis and cerebrospinal fluid otorrhea following tympanostomy tube placement for serous otitis media.

  10. RheoSAXS studies of anisotropic complex fluids under shear

    International Nuclear Information System (INIS)

    Silva, J P de; Petermann, D; Kasmi, B; Imperor-Clerc, M; Davidson, P; Pansu, B; Meneau, F; Perez, J; Paineau, E; Bihannic, I; Michot, L J; Baravian, C

    2010-01-01

    We discuss the application of in-situ rheological small angle X-ray scattering experiments to the study of complex fluids under shear, implemented using custom Couette cylinder rheometers mounted on the SWING beamline of the SOLEIL Synchrotron. We discuss several applications of this technique to the study of phase transitions in nanoparticle doped liquid crystals and shear alignment of clay suspensions. The concurrent capture of rheological and scattering data provides vital information that relates macroscopic properties such as viscosity to the microstructure of the fluid.

  11. Testosterone determination in amniotic fluid for sec diagnosis

    International Nuclear Information System (INIS)

    Quiroa C, M.M.

    1985-11-01

    This study was carried on 50 samples of amniotic fluid obtained from pregnant patients with gestation old of 38 to 40 weeks; diagnosis of the foetus sex was made by measuring the testosterone levels by radioimmunoassay technique. It was found that 94% of the cases were correctly diagnosed. The testosterone levels found in the amniotic fluid of male and female foetus were significantly different (L<0.01) these confirm the efficacy of the method. (author)

  12. Variational description of multifluid hydrodynamics: Uncharged fluids

    Science.gov (United States)

    Prix, Reinhard

    2004-02-01

    We present a formalism for Newtonian multifluid hydrodynamics derived from an unconstrained variational principle. This approach provides a natural way of obtaining the general equations of motion for a wide range of hydrodynamic systems containing an arbitrary number of interacting fluids and superfluids. In addition to spatial variations we use “time shifts” in the variational principle, which allows us to describe dissipative processes with entropy creation, such as chemical reactions, friction or the effects of external non-conservative forces. The resulting framework incorporates the generalization of the entrainment effect originally discussed in the case of the mixture of two superfluids by Andreev and Bashkin. In addition to the conservation of energy and momentum, we derive the generalized conservation laws of vorticity and helicity, and the special case of Ertel’s theorem for the single perfect fluid. We explicitly discuss the application of this framework to thermally conducting fluids, superfluids, and superfluid neutron star matter. The equations governing thermally conducting fluids are found to be more general than the standard description, as the effect of entrainment usually seems to be overlooked in this context. In the case of superfluid 4He we recover the Landau-Khalatnikov equations of the two-fluid model via a translation to the “orthodox” framework of superfluidity, which is based on a rather awkward choice of variables. Our two-fluid model for superfluid neutron star matter allows for dissipation via mutual friction and also “transfusion” via β reactions between the neutron fluid and the proton-electron fluid.

  13. Hydrothermal diamond-anvil cell: Application to studies of geologic fluids

    Science.gov (United States)

    Chou, I.-Ming

    2003-01-01

    The hydrothermal diamond-anvil cell (HDAC) was designed to simulate the geologic conditions of crustal processes in the presence of water or other fluids. The HDAC has been used to apply external pressure to both synthetic and natural fluid inclusions in quartz to minimize problems caused by stretching or decrepitation of inclusions during microthermometric analysis. When the HDAC is loaded with a fluid sample, it can be considered as a large synthetic fluid inclusion and therefore, can be used to study the PVTX properties as well as phase relations of the sample fluid. Because the HDAC has a wide measurement pressure-temperature range and also allows in-situ optical observations, it has been used to study critical phenomena of various chemical systems, such as the geologically important hydrous silicate melts. It is possible, when the HDAC is combined with synchrotron X-ray sources, to obtain basic information on speciation and structure of metal including rare-earth elements (REE) complexes in hydrothermal solutions as revealed by X-ray absorption fine structure (XAFS) spectra. Recent modifications of the HDAC minimize the loss of intensity of X-rays due to scattering and absorption by the diamonds. These modifications are especially important for studying elements with absorption edges below 10 keV and therefore particularly valuable for our understanding of transport and deposition of first-row transition elements and REE in hydrothermal environments.

  14. Diagnosis and treatment of traumatic intracranial hypotension (cerebrospinal fluid hypovolemia)

    International Nuclear Information System (INIS)

    Shinonaga, Masamichi; Suzuki, Shinichi

    2003-01-01

    Patients who complain headache, neck pain, dizziness or vertigo, tinnitus, blurred vision, loss of concentration, memory disturbance and fatigue for over one year after mild head injury and whiplash injury are diagnosed as post-traumatic syndrome. Mechanism and treatment of post-traumatic syndrome are not well established. We studied radioisotope (RI) cisternography and enhanced brain magnetic resonance imaging (MRI) for the patient of post-traumatic syndrome. Of 175 cases in post-traumatic syndrome 141 cases (120 cases of motor vehicle accident, 21 cases of sports injury) were diagnosed, as intracranial hypotension (cerebrospinal fluid hypovolemia). RI cisternography showed 86% positive findings (early accumulation of RI in bladder and leakage). Prominent findings in MRI were dilatation of subdural space and venous dilatation. In every case epidural blood patch was performed and symptoms were improved in almost 70% of patients. This study revealed cerebrospinal fluid hypovolemia might be one cause of post-traumatic syndrome. (author)

  15. Diagnosis and treatment of traumatic intracranial hypotension (cerebrospinal fluid hypovolemia)

    Energy Technology Data Exchange (ETDEWEB)

    Shinonaga, Masamichi [Hiratsuka Kyousai Hospital, Kanagawa (Japan); Suzuki, Shinichi [Inadanoborito Hospital, Kawasaki, Kanagawa (Japan)

    2003-11-01

    Patients who complain headache, neck pain, dizziness or vertigo, tinnitus, blurred vision, loss of concentration, memory disturbance and fatigue for over one year after mild head injury and whiplash injury are diagnosed as post-traumatic syndrome. Mechanism and treatment of post-traumatic syndrome are not well established. We studied radioisotope (RI) cisternography and enhanced brain magnetic resonance imaging (MRI) for the patient of post-traumatic syndrome. Of 175 cases in post-traumatic syndrome 141 cases (120 cases of motor vehicle accident, 21 cases of sports injury) were diagnosed, as intracranial hypotension (cerebrospinal fluid hypovolemia). RI cisternography showed 86% positive findings (early accumulation of RI in bladder and leakage). Prominent findings in MRI were dilatation of subdural space and venous dilatation. In every case epidural blood patch was performed and symptoms were improved in almost 70% of patients. This study revealed cerebrospinal fluid hypovolemia might be one cause of post-traumatic syndrome. (author)

  16. Cerebrospinal fluid γδ T cell frequency is age-related: a case-control study of 435 children with inflammatory and non-inflammatory neurological disorders.

    Science.gov (United States)

    Pranzatelli, M R; Allison, T J; McGee, N R; Tate, E D

    2018-02-27

    Studies of cerebrospinal fluid (CSF) γδ T cells in children are limited, due especially to the lack of control data. In adults, gamma/delta T cells (TCR-γδ) residing in the intrathecal space are sometimes involved in neuroinflammation. To evaluate the possible role of γδ T cells in paediatric neuroinflammation, we immunophenotyped cerebrospinal fluid (CSF) and blood lymphocytes using flow cytometry in a case-control study of 100 children with non-inflammatory neurological disorders (NIND), 312 with opsoclonus-myoclonus (OMS) and 23 with other inflammatory neurological disorders (OIND). In NIND, the negative correlation between CSF γδ T cell frequency and patient age was striking: median frequency of 27% in infants and 3·3% in teens. Interindividual variations were largest in the youngest. There was no gender effect. In all OMS, after correcting for age, only a small effect of OMS severity remained. Measurement of markers for γδ T cell activation [human leucocyte antigen D-related (HLA-DR)], maturation (CD45RA, CD45RO) or intracellular cytokine staining [interleukin (IL)-4, interferon (IFN)-γ] failed to discriminate OMS and NIND groups. Of seven OMS immunotherapies/combinations, none altered the frequency of total CSF γδ T cells or subsets significantly. In OIND, the CSF γδ T cell frequency was disorders [anti-neuronal nuclear antibody (ANNA)-1, PCA-1, teratoma-associated syndrome], cerebellar ataxia (post-infectious, ataxia-telangiectasia), acute disseminated encephalomyelitis, neuroborreliosis and encephalitis. This study provides new insights into CSF γδ T cells in the paediatric population. Although their role in CSF remains elusive, the negative age correlation, resistance to immunotherapy and our age cut-off references for NIND are important findings for the design of future paediatric studies. © 2018 British Society for Immunology.

  17. Amniotic fluid embolism and isolated coagulopathy: atypical presentation of amniotic fluid embolism.

    LENUS (Irish Health Repository)

    Awad, I T

    2012-02-03

    A 41-year-old multigravida presented at 32 weeks of gestation with polyhydramnios and an anencephalic fetus. Abnormal bleeding as a result of disseminated intravascular coagulation complicated an emergency Caesarean section for severe abdominal pain thought to be due to uterine rupture. Massive transfusion with blood products was necessary and the abdomen packed to control bleeding. The patient was transferred to the intensive care unit where she made a slow but complete recovery. Amniotic fluid embolism with atypical presentation of isolated coagulopathy is the likely diagnosis in this case. The case serves to demonstrate that amniotic fluid embolism may present with symptoms and signs other than the classical pattern of dyspnoea, cyanosis and hypotension.

  18. Maintenance fluid therapy and fluid creep impose more significant fluid, sodium, and chloride burdens than resuscitation fluids in critically ill patients: a retrospective study in a tertiary mixed ICU population.

    Science.gov (United States)

    Van Regenmortel, Niels; Verbrugghe, Walter; Roelant, Ella; Van den Wyngaert, Tim; Jorens, Philippe G

    2018-04-01

    Research on intravenous fluid therapy and its side effects, volume, sodium, and chloride overload, has focused almost exclusively on the resuscitation setting. We aimed to quantify all fluid sources in the ICU and assess fluid creep, the hidden and unintentional volume administered as a vehicle for medication or electrolytes. We precisely recorded the volume, sodium, and chloride burdens imposed by every fluid source administered to 14,654 patients during the cumulative 103,098 days they resided in our 45-bed tertiary ICU and simulated the impact of important strategic fluid choices on patients' chloride burdens. In septic patients, we assessed the impact of the different fluid sources on cumulative fluid balance, an established marker of morbidity. Maintenance and replacement fluids accounted for 24.7% of the mean daily total fluid volume, thereby far exceeding resuscitation fluids (6.5%) and were the most important sources of sodium and chloride. Fluid creep represented a striking 32.6% of the mean daily total fluid volume [median 645 mL (IQR 308-1039 mL)]. Chloride levels can be more effectively reduced by adopting a hypotonic maintenance strategy [a daily difference in chloride burden of 30.8 mmol (95% CI 30.5-31.1)] than a balanced resuscitation strategy [daily difference 3.0 mmol (95% CI 2.9-3.1)]. In septic patients, non-resuscitation fluids had a larger absolute impact on cumulative fluid balance than did resuscitation fluids. Inadvertent daily volume, sodium, and chloride loading should be avoided when prescribing maintenance fluids in view of the vast amounts of fluid creep. This is especially important when adopting an isotonic maintenance strategy.

  19. Intraperitoneal fluid collection after laparoscopic appendectomy. Sonographic analysis in asymptomatic patients.

    Science.gov (United States)

    Sales, J P; Adrien, C; Blery, M; Gayral, F

    1995-07-01

    The aim of this prospective study was to evaluate the frequency of postoperative fluid collection after laparoscopic appendectomy in patients with normal postoperative development. Twenty-eight patients were included. The surgical technique, histological data, and postoperative development during the first postoperative month were recorded. A sonographic analysis was performed on the 5th postoperative day by a radiologist who was not aware of the histological and surgical data. Ten cases of fluid collection were found (37%). The frequency was higher in cases of suppurated appendicitis and significantly higher with associated periappendicitis. Peritoneal irrigation or retrocecal dissection did not influence the occurrence of fluid collection. Postoperative serous fluid collection occurs with a high frequency after laparoscopic appendectomies, and one must be careful in interpreting sonographic analyses in looking for deep abscesses in patients with difficult postoperative development.

  20. Piecewise-parabolic methods for astrophysical fluid dynamics

    International Nuclear Information System (INIS)

    Woodward, P.R.

    1983-01-01

    A general description of some modern numerical techniques for the simulation of astrophysical fluid flow is presented. The methods are introduced with a thorough discussion of the especially simple case of advection. Attention is focused on the piecewise-parabolic method (PPM). A description of the SLIC method for treating multifluid problems is also given. The discussion is illustrated by a number of advection and hydrodynamics test problems. Finally, a study of Kelvin-Helmholtz instability of supersonic jets using PPM with SLIC fluid interfaces is presented

  1. Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Hecking Manfred

    2012-06-01

    Full Text Available Abstract Background Data generated with the body composition monitor (BCM, Fresenius show, based on bioimpedance technology, that chronic fluid overload in hemodialysis patients is associated with poor survival. However, removing excess fluid by lowering dry weight can be accompanied by intradialytic and postdialytic complications. Here, we aim at testing the hypothesis that, in comparison to conventional hemodialysis, blood volume-monitored regulation of ultrafiltration and dialysate conductivity (UCR and/or regulation of ultrafiltration and temperature (UTR will decrease complications when ultrafiltration volumes are systematically increased in fluid-overloaded hemodialysis patients. Methods/design BCM measurements yield results on fluid overload (in liters, relative to extracellular water (ECW. In this prospective, multicenter, triple-arm, parallel-group, crossover, randomized, controlled clinical trial, we use BCM measurements, routinely introduced in our three maintenance hemodialysis centers shortly prior to the start of the study, to recruit sixty hemodialysis patients with fluid overload (defined as ≥15% ECW. Patients are randomized 1:1:1 into UCR, UTR and conventional hemodialysis groups. BCM-determined, ‘final’ dry weight is set to normohydration weight −7% of ECW postdialysis, and reached by reducing the previous dry weight, in steps of 0.1 kg per 10 kg body weight, during 12 hemodialysis sessions (one study phase. In case of intradialytic complications, dry weight reduction is decreased, according to a prespecified algorithm. A comparison of intra- and post-dialytic complications among study groups constitutes the primary endpoint. In addition, we will assess relative weight reduction, changes in residual renal function, quality of life measures, and predialysis levels of various laboratory parameters including C-reactive protein, troponin T, and N-terminal pro-B-type natriuretic peptide, before and after the first study

  2. Stokes' second problem for magnetohydrodynamics flow in a Burgers' fluid: the cases γ = λ²/4 and γ>λ²/4.

    Directory of Open Access Journals (Sweden)

    Ilyas Khan

    Full Text Available The present work is concerned with exact solutions of Stokes second problem for magnetohydrodynamics (MHD flow of a Burgers' fluid. The fluid over a flat plate is assumed to be electrically conducting in the presence of a uniform magnetic field applied in outward transverse direction to the flow. The equations governing the flow are modeled and then solved using the Laplace transform technique. The expressions of velocity field and tangential stress are developed when the relaxation time satisfies the condition γ =  λ²/4 or γ> λ²/4. The obtained closed form solutions are presented in the form of simple or multiple integrals in terms of Bessel functions and terms with only Bessel functions. The numerical integration is performed and the graphical results are displayed for the involved flow parameters. It is found that the velocity decreases whereas the shear stress increases when the Hartmann number is increased. The solutions corresponding to the Stokes' first problem for hydrodynamic Burgers' fluids are obtained as limiting cases of the present solutions. Similar solutions for Stokes' second problem of hydrodynamic Burgers' fluids and those for Newtonian and Oldroyd-B fluids can also be obtained as limiting cases of these solutions.

  3. Mathematical modeling and exact solutions to rotating flows of a Burgers' fluid

    International Nuclear Information System (INIS)

    Hayat, T.

    2005-12-01

    The aim of this study is to provide the modeling and exact analytic solutions for hydromagnetic oscillatory rotating flows of an incompressible Burgers' fluid bounded by a plate. The governing time-dependent equation for the Burgers' fluid is different than those from the Navier-Stokes' equation. The entire system is assumed to rotate around an axis normal to the plate. The governing equations for this investigation are solved analytically for two physical problems. The solutions for the three cases, when the two times angular velocity is greater than the frequency of oscillation or it is smaller than the frequency or it is equal to the frequency (resonant case), are discussed in second problem. In Burgers' fluid, it is also found that hydromagnetic solution in the resonant case satisfies the boundary condition at infinity. Moreover, the obtained analytical results reduce to several previously published results as the special cases. (author)

  4. The CHF enhancement on pool boiling using nano-fluids

    International Nuclear Information System (INIS)

    Chang, Won Joon; Jeong, Yong Hoon

    2009-01-01

    A increase of CHF was observed with nano-fluid. The addition of nano-particle helped to increase the wettability. This happens with the decrease in bubble diameter, breakup of bubbles and avoidance of bubble coalescence. CHF increase or decrease depends upon competition between high wettability and high instability. An optimum nano-fluid concentration is needed which must have high crystalline content. When the concentration reaches at a critical value, CHF will tend to a constant value. Deposition of nano-particles increasing the wettability and the rewetting are cause of CHF enhancement. It delay the growth of dry patch by increasing of wettability and lead to CHF enhancement. Now, we must define the wettability of nano-fluids. At case of nano-fluids using metallic particle, the explanation using contact angle using was reasonable. But, at case of nan-fluids using hydrophobic CNT, this explanation can't be acceptable. Moreover, at case of surfactant solution, contact angle was very low. But CHF enhancement was not great. So, wettability about nano-fluids must be defined anew for explanation of CHF enhancement. I suggest the extension of micro layer are acceptable concept for increasing wettability using nano-fluids

  5. Boundary Layer Flow and Heat Transfer with Variable Fluid Properties on a Moving Flat Plate in a Parallel Free Stream

    Directory of Open Access Journals (Sweden)

    Norfifah Bachok

    2012-01-01

    Full Text Available The steady boundary layer flow and heat transfer of a viscous fluid on a moving flat plate in a parallel free stream with variable fluid properties are studied. Two special cases, namely, constant fluid properties and variable fluid viscosity, are considered. The transformed boundary layer equations are solved numerically by a finite-difference scheme known as Keller-box method. Numerical results for the flow and the thermal fields for both cases are obtained for various values of the free stream parameter and the Prandtl number. It is found that dual solutions exist for both cases when the fluid and the plate move in the opposite directions. Moreover, fluid with constant properties shows drag reduction characteristics compared to fluid with variable viscosity.

  6. Numerical analysis of viscoelastic boundary layers : the case of plate withdrawal in a Maxwellian fluid

    International Nuclear Information System (INIS)

    Sadeghy, K.; Sharifi, M.

    2002-01-01

    The effect of a fluid's elasticity on the characteristics of its boundary layer was investigated in this work. A viscoelastic fluid of Maxwellian type was selected for this purpose and the flow induced in this fluid by a plate withdrawing at a constant velocity was studied. Conventional boundary layer assumptions were invoked to reduce the equations of motion to a simple form incorporating an elastic term in addition to the familiar inertial, viscous and pressure terms. It was shown that for elastic effects to be of an importance in a boundary layer, the fluid's relaxation time should be of an order much larger than its kinematic viscosity. By introducing a stream function, the governing equation was transformed into a nonlinear ODE with x-coordinate still appearing in the equation demonstrating that no similarity solution existed for this flow. The resulting equation was then solved numerically for Deborah numbers as large as 1.0. The results showed a marked formation of boundary layer adjacent to a moving wall for a Maxwellian fluid. The boundary layer thickness and the wall shear stress were found to scale with fluid's elasticity - both decreasing the higher the fluid's elasticity. It is thus anticipated that in free coating processes, the force required to impart a constant velocity to a withdrawing belt or plate would be lower if fluid's elasticity is significant. (author)

  7. Tourmaline orbicules in peraluminous monzogranites of Argentina: A study case of fluid-rock interaction between leucogranite and country-rock metasediments

    Science.gov (United States)

    Lira, Raúl; Poklepovic, María F.

    2017-12-01

    Tourmaline orbicules hosted in peraluminous granites are documented worldwide. Seven occurrences were identified in Argentina. Petrography, mineral chemistry, whole-rock geochemistry mass balance and microthermometric studies were performed in orbicules formed at the cupola of a peraluminous A-type leucogranite (Los Riojanos pluton), as well as complementary investigation was achieved in other orbicules of similar geological setting. Mass balance computations in zoned orbicules consistently confirmed immobility of Si both in core and halo, immobility of K and little loss of Al during halo reactions. Elements gained and lost in the schorl-rich core are Fe, Al, Mg, Ti, Ba, Sr, Y and Zr, and Na, K, Rb and Nb, respectively; in the halo, K, Ba, Sr, Y, Zr and locally CaO, were gained, and Fe, Mg, Na, Al, Rb and Nb were lost. The schorl-rich core is enriched in LREE relative to the leucogranite host. A temperature-salinity plot from fluid inclusion data delineates a magmatic-meteoric mixing trend of diluting salinity with descending temperature. Computed δDH20 values from Los Riojanos orbicule schorl suggest magmatic and magmatic-meteoric mixed origins. In Los Riojanos, mass balance constraints suggest that Fe, Mg, Ba, Sr and metallic traces like Zn and V (±Pb) were most likely derived from country-rock schists and gneisses through fluid-rock exchange reactions. A late magmatic-, volatile-rich- fluid exsolution scenario for the formation of orbicules is envisaged. Schorl crystallization was likely delayed to the latest stages of leucogranite consolidation, not only favored by the high diffusivity of B2O3 preferentially partitioned into the exsolved aqueous-rich fluid, but also likely limited to the low availability of Fe and Mg from the scarce granitic biotite, and to the high F- content of the melt. The spatial confination of orbicules to the contact zone granite-metasediments suggests that orbicules were not formed until exsolved fluids reached the boundary with the

  8. A model of scientific attitudes assessment by observation in physics learning based scientific approach: case study of dynamic fluid topic in high school

    Science.gov (United States)

    Yusliana Ekawati, Elvin

    2017-01-01

    This study aimed to produce a model of scientific attitude assessment in terms of the observations for physics learning based scientific approach (case study of dynamic fluid topic in high school). Development of instruments in this study adaptation of the Plomp model, the procedure includes the initial investigation, design, construction, testing, evaluation and revision. The test is done in Surakarta, so that the data obtained are analyzed using Aiken formula to determine the validity of the content of the instrument, Cronbach’s alpha to determine the reliability of the instrument, and construct validity using confirmatory factor analysis with LISREL 8.50 program. The results of this research were conceptual models, instruments and guidelines on scientific attitudes assessment by observation. The construct assessment instruments include components of curiosity, objectivity, suspended judgment, open-mindedness, honesty and perseverance. The construct validity of instruments has been qualified (rated load factor > 0.3). The reliability of the model is quite good with the Alpha value 0.899 (> 0.7). The test showed that the model fits the theoretical models are supported by empirical data, namely p-value 0.315 (≥ 0.05), RMSEA 0.027 (≤ 0.08)

  9. On Hall current fluid

    International Nuclear Information System (INIS)

    Shen, M.C.; Ebel, D.

    1987-01-01

    In this paper some new results concerning magnetohydrodynamic (MHD) equations with the Hall current (HC) term in the Ohm's law are presented. For the cylindrical pinch of a compressible HC fluid, it is found that for large time and long wave length the solution to the governing equations exhibits the behavior of solitons as in the case of an ideal MHD model. In some special cases, the HC model appears to be better posed. An open question is whether a simple toroidal equilibrium of an HC fluid with resistivity and viscosity exists. The answer to this question is affirmative if the prescribed velocity on the boundary has a small norm. Furthermore, the equilibrium is also linearly and nonlinearly stable

  10. Fluid Petri Nets and hybrid model-checking: a comparative case study

    International Nuclear Information System (INIS)

    Gribaudo, M.; Horvath, A.; Bobbio, A.; Tronci, E.; Ciancamerla, E.; Minichino, M.

    2003-01-01

    The modeling and analysis of hybrid systems is a recent and challenging research area which is actually dominated by two main lines: a functional analysis based on the description of the system in terms of discrete state (hybrid) automata (whose goal is to ascertain conformity and reachability properties), and a stochastic analysis (whose aim is to provide performance and dependability measures). This paper investigates a unifying view between formal methods and stochastic methods by proposing an analysis methodology of hybrid systems based on Fluid Petri Nets (FPNs). FPNs can be analyzed directly using appropriate tools. Our paper shows that the same FPN model can be fed to different functional analyzers for model checking. In order to extensively explore the capability of the technique, we have converted the original FPN into languages for discrete as well as hybrid as well as stochastic model checkers. In this way, a first comparison among the modeling power of well known tools can be carried out. Our approach is illustrated by means of a 'real world' hybrid system: the temperature control system of a co-generative plant

  11. Mixture of working fluids in ORC plants with pool boiler evaporator

    International Nuclear Information System (INIS)

    Rajabloo, Talieh; Iora, Paolo; Invernizzi, Costante

    2016-01-01

    Highlights: • We assess the feasibility of pool boiler in ORCs operating with mixture working fluids. • We consider hydrocarbon and siloxane mixtures for low and high temperature ORCs. • Plants with pool boiler show comparable performances to once through evaporator. - Abstract: Power generation using Organic Rankine Cycle was studied in this paper in case of both low and high temperature cycles, exploiting respectively a geothermal heat source available at 167 °C, and heat available at 300 °C from the combustion of biomass. In particular we assess the feasibility of employing mixture of working fluids, in the case of replacing the typical once-through (OT) evaporator with the pool boiler (PB) technology, typically adopted for pure fluids. The analysis evidenced that in general the OT evaporator shows a slightly improved cycle performance in comparison to the PB and it results in some cases advantageous with respect to the pure working fluid. For instance in case of low temperature cycle, the best thermodynamic performances are obtained with mixture of i-C_5 and 75% n-C_4 in case of OT evaporator, yielding a recovery efficiency higher than the case with pure i-C_5 (7.7 vs. 7.4%) given the relatively higher values of both the recovery factor and cycle efficiency. Implementation of PB did not affect the plant performance significantly which shows the feasibility of having PB with potentially easier control.

  12. Fatigue damage in nuclear power plants: cases study

    International Nuclear Information System (INIS)

    Goltrant, O.; Thebault, Y.

    2001-01-01

    Some fatigue cracks have been detected on nuclear power plants components. Generally they appears under local solicitations not correctly predicted. Two cases are presented in this paper to illustrate the problem: the pitting during mechanical fatigue where the stresses are induced by the pumps vibrations or by fluid flow; the mixing zones of RRA circuit (N4 bearing) where the stresses are induced by the flow of different temperature fluids. The examination allowed the identification of the cracking origin and the development of corrective solutions. (A.L.B.)

  13. Evolutionary space station fluids management strategies

    Science.gov (United States)

    1989-01-01

    Results are summarized for an 11-month study to define fluid storage and handling strategies and requirements for various specific mission case studies and their associated design impacts on the Space Station. There are a variety of fluid users which require a variety of fluids and use rates. Also, the cryogenic propellants required for NASA's STV, Planetary, and Code Z missions are enormous. The storage methods must accommodate fluids ranging from a high pressure gas or supercritical state fluid to a sub-cooled liquid (and superfluid helium). These requirements begin in the year 1994, reach a maximum of nearly 1800 metric tons in the year 2004, and trail off to the year 2018, as currently planned. It is conceivable that the cryogenic propellant needs for the STV and/or Lunar mission models will be met by LTCSF LH2/LO2 tanksets attached to the SS truss structure. Concepts and corresponding transfer and delivery operations have been presented for STV propellant provisioning from the SS. A growth orbit maneuvering vehicle (OMV) and associated servicing capability will be required to move tanksets from delivery launch vehicles to the SS or co-orbiting platforms. Also, appropriate changes to the software used for OMV operation are necessary to allow for the combined operation of the growth OMV. To support fluid management activities at the Space Station for the experimental payloads and propellant provisioning, there must be truss structure space allocated for fluid carriers and propellant tanksets, and substantial beam strengthening may be required. The Station must have two Mobile Remote Manipulator Systems (MRMS) and the growth OMV propellant handling operations for the STV at the SS. Propellant needs for the Planetary Initiatives and Code Z mission models will most likely be provided by co-orbiting propellant platform(s). Space Station impacts for Code Z mission fluid management activities will be minimal.

  14. Fluids in crustal deformation: Fluid flow, fluid-rock interactions, rheology, melting and resources

    Science.gov (United States)

    Lacombe, Olivier; Rolland, Yann

    2016-11-01

    Fluids exert a first-order control on the structural, petrological and rheological evolution of the continental crust. Fluids interact with rocks from the earliest stages of sedimentation and diagenesis in basins until these rocks are deformed and/or buried and metamorphosed in orogens, then possibly exhumed. Fluid-rock interactions lead to the evolution of rock physical properties and rock strength. Fractures and faults are preferred pathways for fluids, and in turn physical and chemical interactions between fluid flow and tectonic structures, such as fault zones, strongly influence the mechanical behaviour of the crust at different space and time scales. Fluid (over)pressure is associated with a variety of geological phenomena, such as seismic cycle in various P-T conditions, hydrofracturing (including formation of sub-horizontal, bedding-parallel veins), fault (re)activation or gravitational sliding of rocks, among others. Fluid (over)pressure is a governing factor for the evolution of permeability and porosity of rocks and controls the generation, maturation and migration of economic fluids like hydrocarbons or ore forming hydrothermal fluids, and is therefore a key parameter in reservoir studies and basin modeling. Fluids may also help the crust partially melt, and in turn the resulting melt may dramatically change the rheology of the crust.

  15. Fluid/structure interaction in BERDYNE (Level 4)

    International Nuclear Information System (INIS)

    Fox, M.J.H.

    1988-02-01

    A fluid-structure interaction capability has been developed for Level 4 of the finite element dynamics code BERDYNE, as part of the BERSAFE structural analysis system. This permits analysis of small amplitude free or forced vibration of systems comprising elastic structural components and inviscid volumes of possibly compressible fluid. Free fluid surfaces under the influence of gravity may be present. The formulation chosen uses the rigid walled fluid modes, calculated in a preliminary stage, as a basis for description of the coupled system, providing symmetric system matrices for which efficient solution procedures are available. The inclusion of the fluid modal variables within the system matrices is carried out through the use of the BERDYNE 'substructuring' feature, which allows the inclusion of very general 'super-elements' among the normal structural elements. The program also has a seismic analysis capability, used for the analysis of fluid-structure systems subjected to a specified support acceleration time history. In this case analysis is carried out in terms of relative structural motions, but absolute fluid pressures. Application of the BERDYNE fluid/structure interaction capability to some simple test cases produced results in good agreement with results obtained by analytic or independent numerical techniques. Full instructions on the use of the facility will be included in the BERDYNE Level 4 documentation. Interim documentation for the pre-release version is available from the author. (author)

  16. Gyro-fluid and two-fluid theory and simulations of edge-localized-modes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, X. Q.; Dimits, A.; Joseph, I.; Umansky, M. V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Xi, P. W. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); School of Physics, Peking University, Beijing (China); Xia, T. Y.; Gui, B. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Kim, S. S.; Park, G. Y.; Rhee, T.; Jhang, H. [WCI Center for Fusion Theory, National Fusion Research Institute, Daejon 305-333 (Korea, Republic of); Diamond, P. H. [WCI Center for Fusion Theory, National Fusion Research Institute, Daejon 305-333 (Korea, Republic of); Center for Astrophysics and Space Sciences and Department of Physics, University of California, San Diego, La Jolla, California 92093-0424 (United States); Dudson, B. [University of York, Heslington, York YO10 5DD (United Kingdom); Snyder, P. B. [General Atomics, San Diego, California 92186 (United States)

    2013-05-15

    This paper reports on the theoretical and simulation results of a gyro-Landau-fluid extension of the BOUT++ code, which contributes to increasing the physics understanding of edge-localized-modes (ELMs). Large ELMs with low-to-intermediate-n peeling-ballooning (P-B) modes are significantly suppressed due to finite Larmor radius (FLR) effects when the ion temperature increases. For type-I ELMs, it is found from linear simulations that retaining complete first order FLR corrections as resulting from the incomplete “gyroviscous cancellation” in Braginskii's two-fluid model is necessary to obtain good agreement with gyro-fluid results for high ion temperature cases (T{sub i}≽3 keV) when the ion density has a strong radial variation, which goes beyond the simple local model of ion diamagnetic stabilization of ideal ballooning modes. The maximum growth rate is inversely proportional to T{sub i} because the FLR effect is proportional to T{sub i}. The FLR effect is also proportional to toroidal mode number n, so for high n cases, the P-B mode is stabilized by FLR effects. Nonlinear gyro-fluid simulations show results that are similar to those from the two-fluid model, namely that the P-B modes trigger magnetic reconnection, which drives the collapse of the pedestal pressure. Due to the additional FLR-corrected nonlinear E × B convection of the ion gyro-center density, for a ballooning-dominated equilibrium the gyro-fluid model further limits the radial spreading of ELMs. In six-field two fluid simulations, the parallel thermal diffusivity is found to prevent the ELM encroachment further into core plasmas and therefore leads to steady state L-mode profiles. The simulation results show that most energy is lost via ion channel during an ELM event, followed by particle loss and electron energy loss. Because edge plasmas have significant spatial inhomogeneities and complicated boundary conditions, we have developed a fast non-Fourier method for the computation of

  17. Review of computational fluid dynamics (CFD) researches on nano fluid flow through micro channel

    Science.gov (United States)

    Dewangan, Satish Kumar

    2018-05-01

    Nanofluid is becoming a promising heat transfer fluids due to its improved thermo-physical properties and heat transfer performance. Micro channel heat transfer has potential application in the cooling high power density microchips in CPU system, micro power systems and many such miniature thermal systems which need advanced cooling capacity. Use of nanofluids enhances the effectiveness of t=scu systems. Computational Fluid Dynamics (CFD) is a very powerful tool in computational analysis of the various physical processes. It application to the situations of flow and heat transfer analysis of the nano fluids is catching up very fast. Present research paper gives a brief account of the methodology of the CFD and also summarizes its application on nano fluid and heat transfer for microchannel cases.

  18. Diagnostic significance of pleural fluid adenosine deaminase activity in tuberculous pleurisy

    Directory of Open Access Journals (Sweden)

    Sharmeen Ahmed

    2011-01-01

    Full Text Available Diagnosis of tuberculous pleural effusion (TPE is difficult because of its non-specific clinical presentation and insufficient efficiency of conventional diagnostic methods. The study was carried out to evaluate the utility of adenosine deaminase (ADA activity in pleural fluid for the diagnosis of TPE. ADA activity was measured in pleural fluid of 103 pleural effusion patients by colorimetric method using a commercial ADA assay kit. The diagnosis of TPE was made from pleural fluid examinations (including cytology, biochemistry, and bacteriology and pleural biopsy. Patient with negative result of this methods were diagnosed by response of empirical treatment. Out of 130 cases, 62 (61.1% had TPE and the remaining 41 (39.8% had pleural effusion due to non tuberculous diseases. There was statistically significant difference (p < 0.001 between the mean of pleural fluid ADA levels (70.82±22.54 U/L in TPE group and (30.07±22.93 U/L in non-TPE group. Of 62 TPE cases, microscopy for AFB and culture for M.tuberculosis in pleural fluid revealed positivity in 9.6% and 22.5% cases respectively, and biopsy of pleura showed typical epithelioid granuloma in only 43.5% cases. The cut-off value of ADA for diagnosing TPE was 40 U/L using a ROC curve, with a sensitivity of 94% and specificity of 88%. Positive and negative predictive value of ADA assay were 92% and 90% respectively. The overall test accuracy was 90%. Pleural fluid ADA assay is therefore a simple, rapid, highly sensitive and specific adjunct test for diagnosis of TPE. Ibrahim Med. Coll. J. 2011; 5(1: 1-5

  19. Positive FAST without hemoperitoneum due to fluid resuscitation in blunt trauma.

    Science.gov (United States)

    Slutzman, Jonathan E; Arvold, Lisa A; Rempell, Joshua S; Stone, Michael B; Kimberly, Heidi H

    2014-10-01

    The focused assessment with sonography in trauma (FAST) examination is an important screening tool in the evaluation of blunt trauma patients. To describe a case of a hemodynamically unstable polytrauma patient with positive FAST due to fluid resuscitation after blunt trauma. We describe a case of a hemodynamically unstable polytrauma patient who underwent massive volume resuscitation prior to transfer from a community hospital to a trauma center. On arrival at the receiving institution, the FAST examination was positive for free intraperitoneal fluid, but no hemoperitoneum or significant intra-abdominal injuries were found during laparotomy. In this case, it is postulated that transudative intraperitoneal fluid secondary to massive volume resuscitation resulted in a positive FAST examination. This case highlights potential issues specific to resuscitated trauma patients with prolonged transport times. Further study is likely needed to assess what changes, if any, should be made in algorithms to address the effect of prior resuscitative efforts on the test characteristics of the FAST examination. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Temporal stability of superposed magnetic fluids in porous media

    International Nuclear Information System (INIS)

    Zakaria, Kadry; Sirwah, Magdy A; Alkharashi, Sameh

    2008-01-01

    The present work deals with the stability properties of time periodically streaming superposed magnetic fluids through porous media under the influence of an oblique alternating magnetic field. The system is composed of a middle fluid sheet of finite thickness embedded between two other bounded layers. The fluids are assumed to be incompressible and there are no volume charges in the layers of the fluids. Such configurations are of relevance in a variety of astrophysical and space configurations. The solutions of the linearized equations of motion and boundary conditions lead to deriving two more general simultaneous Mathieu equations of damping terms with complex coefficients. The method of multiple time scales is used to obtain approximate solutions and analyze the stability criteria for both the non-resonant and resonant cases and hence transition curves are obtained for such cases. The stability criteria are examined theoretically and numerically from which stability diagrams are obtained. It is found that the fluid sheet thickness plays a destabilizing role in the presence of a constant field and velocity, while the damping role is observed for the resonant cases. Dual roles are observed for the fluid velocity and the porosity in the stability criteria

  1. [Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].

    Science.gov (United States)

    Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta

    2008-09-01

    The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.

  2. Procalcitonin levels in patients with positive blood culture, positive body fluid culture, sepsis, and severe sepsis: a cross-sectional study.

    Science.gov (United States)

    Yu, Ying; Li, Xia-Xi; Jiang, Ling-Xiao; Du, Meng; Liu, Zhan-Guo; Cen, Zhong-Ran; Wang, Hua; Guo, Zhen-Hui; Chang, Ping

    2016-01-01

    Numerous investigations on procalcitonin (PCT) have been carried out, although few with large sample size. To deal with the complexity of sepsis, an understanding of PCT in heterogeneous clinical conditions is required. Hospitalized patients aged 10-79 years were included in this retrospective and cross-sectional study. PCT tests were assayed within 2 days of blood culture. A total of 2952 cases (from 2538 patients) were enrolled in this study, including 440 cases in the 'positive BC' group, 123 cases in the 'positive body fluid culture' group, and 2389 cases in the 'negative all culture' group. Median PCT values were 4.53 ng/ml, 2.95 ng/ml, and 0.49 ng/ml, respectively. Median PCT values in the gram-negative BC group and gram-positive BC group, respectively, were 6.99 ng/ml and 2.96 ng/ml. Median PCT values in the 'positive hydrothorax culture' group, 'positive ascites culture' group, 'positive bile culture' group, and 'positive cerebrospinal fluid culture' group, respectively, were 1.39 ng/ml, 8.32 ng/ml, 5.98 ng/ml, and 0.46 ng/ml. In all, 357 cases were classified into the 'sepsis' group, 150 of them were classified into the 'severe sepsis' group. Median PCT values were 5.63 ng/ml and 11.06 ng/ml, respectively. PCT could be used in clinical algorithms to diagnose positive infections and sepsis. Different PCT levels could be related to different kinds of microbemia, different infection sites, and differing severity of sepsis.

  3. Case Study: Testing with Case Studies

    Science.gov (United States)

    Herreid, Clyde Freeman

    2015-01-01

    This column provides original articles on innovations in case study teaching, assessment of the method, as well as case studies with teaching notes. This month's issue discusses using case studies to test for knowledge or lessons learned.

  4. Numerical Study of Thermo-Fluid Features of Electrically Conducting Fluids in Tube Bank Heat Exchangers Exposed to Uniform Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jin Ho; Kang, Namcheol [Kyungpook Nat’l Univ., Daegu (Korea, Republic of)

    2017-10-15

    When an electrically conducting fluid flows through a staggered tube bank, the heat transfer and fluid flow features are changed by the externally introduced magnetic field. This study provides a numerical investigation of this phenomenon. Heat and fluid flows are investigated for unsteady laminar flows at Reynolds numbers of 50 and 100 with the Hartmann number gradually increasing from zero to 100. As the Hartmann number increases, and owing to the effects of the introduced magnetic field, the velocity boundary layer near the tube wall is thinned, the flow separation is delayed downstream, and the shrinkage of a recirculation zone formed near the rear side is observed. Based on these thermo-fluid deformations, the resulting changes in the local and average Nusselt number are investigated.

  5. Multi-temperature mixture of fluids

    Directory of Open Access Journals (Sweden)

    Ruggeri Tommaso

    2009-01-01

    Full Text Available We present a survey on some recent results concerning the different models of a mixture of compressible fluids. In particular we discuss the most realistic case of a mixture when each constituent has its own temperature (MT and we first compare the solutions of this model with the one with a unique common temperature (ST . In the case of Eulerian fluids it will be shown that the corresponding (ST differential system is a principal subsystem of the (MT one. Global behavior of smooth solutions for large time for both systems will also be discussed through the application of the Shizuta-Kawashima condition. Then we introduce the concept of the average temperature of mixture based upon the consideration that the internal energy of the mixture is the same as in the case of a single-temperature mixture. As a consequence, it is shown that the entropy of the mixture reaches a local maximum in equilibrium. Through the procedure of Maxwellian iteration a new constitutive equation for non-equilibrium temperatures of constituents is obtained in a classical limit, together with the Fick's law for the diffusion flux. Finally, to justify the Maxwellian iteration, we present for dissipative fluids a possible approach of a classical theory of mixture with multi-temperature and we prove that the differences of temperatures between the constituents imply the existence of a new dynamical pressure even if the fluids have a zero bulk viscosity.

  6. Boundary layer for non-newtonian fluids on curved surfaces

    International Nuclear Information System (INIS)

    Stenger, N.

    1981-04-01

    By using the basic equation of fluid motion (conservation of mass and momentum) the boundary layer parameters for a Non-Newtonian, incompressible and laminar fluid flow, has been evaluated. As a test, the flat plate boundary layer is first analized and afterwards, a case with pressure gradient, allowing separation, is studied. In the case of curved surfaces, the problem is first developed in general and afterwards particularized to a circular cylinder. Finally suction and slip in the flow interface are examined. The power law model is used to represent the stress strain relationship in Non-Newtonian flow. By varying the fluid exponent one can then, have an idea of how the Non-Newtonian behavior of the flow influences the parameters of the boundary layer. Two equations, in an appropriate coordinate system have been obtained after an order of magnitude analysis of the terms in the equations of motion is performed. (Author) [pt

  7. Scintigraphy of the cerebrospinal fluid

    International Nuclear Information System (INIS)

    Touya, E.; Perillo, W.; Paez, A.; Osorio, A.; Ferrando, R.; Lago, G.; Garcia Guelfi, A.; Ferrari, M.

    1977-01-01

    Eight years of experience in scintigraphy of cerebrospinal fluid (CSF) with 113 Insup(m)-colloid is reported. Two hundred cases are discussed. On the basis of the clinical diagnosis, the cases are divided into five groups: (1) spinal cord compression; (2) hydrocephalus of the adult and child; (3) control of extracranial CSF shunts; (4) CSF fistula; and (5) brain tumour. It is concluded that the radiopharmaceutical used has no limitations except in the study of the hydrocephalus of the adult. For those services remote from the production centres, it is a convenient option for CSF scintigraphy. (author)

  8. Progresses on the computation of added masses for fluid structure interaction

    International Nuclear Information System (INIS)

    Lazzeri, L.; Cecconi, S.; Scala, M.

    1985-01-01

    The problem of coupled vibrations of fluids and structures is analyzed, in the case of irrotational incompressible fluid fields the effect is modelled as an added mass matrix. The Modified Boundary Elements technique is used; a particular case (cylindrical reservois with sloshing) and the general case are examined. (orig.)

  9. Numerical method for studying the circulation patterns of a fluid in a cavity

    International Nuclear Information System (INIS)

    Stephani, L.M.; Butler, T.D.

    1975-10-01

    The method incorporates three circulation-inducing mechanisms: (1) buoyancy induced by nonuniform initial distribution of heat throughout the fluid, (2) buoyancy induced by removal of heat from the fluid, and (3) forced convection induced by withdrawal of heated fluid and return of cooled fluid. A two-dimensional computer program, CIRCO, based on the Marker-and-Cell (MAC) technique, is used to study the circulation patterns. The report discusses the code and illustrates its capabilities by means of examples from studies conducted for the Pacer project, which investigates the concept of producing electrical power from energy released by thermonuclear explosions in a salt dome. Efficient engineering for withdrawing energy from the cavity requires an understanding of the circulation patterns of the heated fluid. CIRCO provides this information in the form of computer-generated plots

  10. Fluid Characteristics in the Giant Quartz Reef System of the Bundelkhand Craton, India: Constraints from Fluid Inclusion Study

    Science.gov (United States)

    Rout, D.; Panigrahi, M. K.; Pati, J. K.

    2017-12-01

    Giant quartz reefs are anomalous features indicating extensive mobilization of silica in the crust. Such reefs in the Abitibi belt, Canada and elsewhere are believed to be the result of activity of fluid of diverse sources on terrain boundaries. The Bundelkhand granitoid complex constituting a major part of the Bundelkhnad Craton in north-Central India is traversed by numerous such quartz reefs all across for a length of about 500 km. There are about 20 major reefs having dimensions of 35 to 40 km in length, 50 to 60 m in width standing out as prominent ridges in the region. Almost all are aligned parallel to each other in a sub-vertical to vertical manner following the NE-SW to NNE-SSW trend. Fluid inclusion petrography in quartz from these reefs reveal four types of inclusions viz. aqueous biphase (type-I), pure carbonic (type-II), aqueous carbonic (type-III) and polyphase (type-IV) inclusions. The type-I aqueous biphase inclusions are the dominant type in all the samples studied so far. Salinities calculated from temperature of melting of last ice (Tm) values are low to moderate, ranging from 0.18 to 18.19 wt% NaCl equivalents. Temperature of liquid-vapor homogenization (Th) values of these inclusions show a wide range from 101 ºC to 386 ºC (cluster around 150-250 ºC) essentially into liquid phase ruling out boiling during its course of evolution. Besides, aqueous Biphase inclusions, some data on pure CO2 inclusions furnish a near constant value of TmCO2 at -56.6 ºC in the Bundelkhand Craton indicating absence of CH4. Bivariate plot between Th and salinity suggest three possible water types which are controlling the overall activity of fluid in quartz reefs of Bundelkhand Craton viz. low-T low saline, high-T low saline and moderate-T and moderate saline. A low saline and CO2-bearing and higher temperature nature resembles a metamorphic fluid that may be a source for these giant quartz reefs. The low temperature low-salinity component could be a meteoric

  11. Marker evaluation for differentiation of blood and menstrual fluid by methylation-sensitive SNaPshot analysis.

    Science.gov (United States)

    Holtkötter, Hannah; Schwender, Kristina; Wiegand, Peter; Pfeiffer, Heidi; Vennemann, Marielle

    2018-03-01

    The differentiation of blood and menstrual fluid is especially important in cases of alleged sexual assault. While the identification of blood is relatively straightforward, the identification of menstrual fluid in trace evidence has been shown to be more challenging. This may be due to the complex nature of menstrual fluid that leads to intra- and inter-individual differences in composition. Nevertheless, recent advances in DNA methylation profiling have revealed promising markers for the differentiation of the two body fluids and furthermore, markers to distinguish menstrual fluid from vaginal fluid. A literature study was performed and in total, 11 markers were evaluated in this study of which seven could be validated for menstrual fluid and blood identification purposes. Marker "BLU2" (chr16:29757334) was identified as most suitable for differentiation of blood and menstrual fluid.

  12. X-ray and neutron scattering studies of complex confined fluids

    International Nuclear Information System (INIS)

    Sinha, S. K.

    1999-01-01

    We review recent X-ray and neutron scattering studies of the structure and dynamics of confined complex fluids. This includes the study of polymer conformations and binary fluid phase transitions in porous media using Small Angle Neutron scattering, and the use of synchrotrons radiation to study ordering and fluctuation phenomena at solid/liquid and liquid/air interfaces. Ordering of liquids near a solid surface or in confinement will be discussed, and the study, via specular and off-specular X-ray reflectivity, of capillary wave fluctuations on liquid polymer films. Finally, we shall discuss the use of high-brilliance beams from X-ray synchrotrons to study via photon correlation spectroscopy the slow dynamics of soft condensed matter systems

  13. Atomic dynamics in fluids studied by inelastic x-ray scattering

    International Nuclear Information System (INIS)

    Inui, Masanori; Kajihara, Yukio; Matsuda, Kazuhiro; Ishikawa, Daisuke; Tsutsui, Satoshi; Baron, Alfred Q.

    2010-01-01

    Studies on atomic dynamics in supercritical fluids at high temperature and high pressure have remarkably been advanced by using an inelastic x-ray scattering technique that achieved a meV-energy resolution in the middle of 1990's. In this article, we describe a brief review of the theoretical background on liquid dynamics, our own high-temperature high-pressure technique and recent results of atomic dynamics in supercritical fluids. In particular, we report the results of inelastic x-ray scattering measurements for expanding fluid Hg at high temperature and high pressure, which were conduced at BL35XU/SPring-8. We found that in the metal-nonmetal transition in fluid Hg, the excitation energy of the acoustic mode disperses three times faster than the adiabatic sound velocity obtained by ultrasonic measurements. This phenomenon must be crucial to understand how a metallic state is formed during atomic condensation accurately. Finally we put a future development of this field in perspective. (author)

  14. Tracking Hydrothermal Fluid Pathways from Surface Alteration Mineralogy: The Case of Licancura Geothermal Field, Northern Chile

    Science.gov (United States)

    Camus, E.; Elizalde, J. D.; Morata, D.; Wechsler, C.

    2017-12-01

    In geothermal systems alteration minerals are evidence of hot fluid flow, being present even in absence of other surface manifestations. Because these minerals result from the interaction between geothermal fluids and surrounding host rocks, they will provide information about features of thermal fluids as temperature, composition and pH, allowing tracking their changes and evolution. In this work, we study the Licancura Geothermal field located in the Andean Cordillera in Northern Chile. The combination of Principal Components Analysis on ASTER-L1T imagery and X Ray Diffraction (XRD) allow us to interpret fluid conditions and the areas where fluid flow took place. Results from red, green, blue color composite imagery show the presence of three types of secondary paragenesis. The first one corresponds to hematite and goethite, mainly at the east of the area, in the zone of eroded Pliocene volcanic edifices. The second one, mainly at the center of the area, highlighting propylitic alteration, includes minerals such as chlorite, illite, calcite, zeolites, and epidote. The third paragenesis, spatially related to the intersection between faults, represents advanced argillic alteration, includes minerals as alunite, kaolinite, and jarosite. XRD analysis support results from remote sensing techniques. These results suggest an acid pH hydrothermal fluid reaching temperatures at surface up to 80-100°C, which used faults as a conduit, originating advanced argillic minerals. The same fluid was, probably, responsible for propylitic paragenesis. However, iron oxides paragenesis identified in the area of eroded volcanoes probably corresponds to other processes associated with weathering rather than geothermal activity. In this work, we propose the applicability of remote sensing techniques as a first level exploration tool useful for high-altitude geothermal fields. Detailed clay mineral studies (XRD and SEM) would allow us to a better characterization of the geothermal fluid

  15. Fluid-structure interaction in tube bundles: homogenization methods, physical analysis

    International Nuclear Information System (INIS)

    Broc, D.; Sigrist, J.F.

    2009-01-01

    It is well known that the movements of a structure may be strongly influenced by fluid. This topic, called 'Fluid Structure Interaction' is important in many industrial applications. Tube bundles immersed in fluid are found in many cases, especially in nuclear industry: (core reactors, steam generators,...). The fluid leads to 'inertial effects' (with a decrease of the vibration frequencies) and 'dissipative effects' (with higher damping). The paper first presents the methods used for the simulation of the dynamic behaviour of tube bundles immersed in a fluid, with industrial examples. The methods used are based on the Euler equations for the fluid (perfect fluid), which allow to take into account the inertial effects. It is possible to take into account dissipative effects also, by using a Rayleigh damping. The conclusion focuses on improvements of the methods, in order to take into account with more accuracy the influence of the fluid, mainly the dissipative effects, which may be very important, especially in the case of a global fluid flow. (authors)

  16. Pleural effusion: Role of pleural fluid cytology, adenosine deaminase level, and pleural biopsy in diagnosis

    Directory of Open Access Journals (Sweden)

    Biswajit Biswas

    2016-01-01

    Full Text Available Objective: The present study is designed to evaluate the role of pleural fluid analysis in diagnosing pleural diseases and to study the advantages and disadvantages of thoracocentasis and pleural biopsy. Materials and Methods: We prospectively included 66 consecutive indoor patients over a duration of 1 year. Pleural fluid was collected and cytological smears were made from the fluid. Plural biopsy was done in the same patient by Cope needle. Adequate pleural biopsy tissue yielding specific diagnosis was obtained in 47 (71.2% cases. Results: Tuberculosis was the commonest nonneoplastic lesion followed by chronic nonspecific pleuritis comprising 60% and 33.3% of the nonneoplastic cases respectively and tuberculosis was predominantly diagnosed in the younger age group. Majority (70.8% of malignancy cases were in the age group of >50-70. Adenocarcinoma was found to be the commonest (66.7% malignant neoplasm in the pleurae followed by small-cell carcinoma (20.8%. Conclusion: Pleural biopsy is a useful and minimally invasive procedure. It is more sensitive and specific than pleural fluid smears.

  17. Adaptation of systems to fluid changes; Adaptation des systemes aux changements de fluides

    Energy Technology Data Exchange (ETDEWEB)

    Clodic, D. [Ecole Nationale Superieure des Mines, 75 - Paris (France)

    1996-12-31

    Regulation constraints and the stoppage of CFCs production and HCFCs production in the future lead to rapid evolutions in the conceiving of refrigerating installations which are linked with refrigerant changes. The refrigerant/installation pair has become the aim of detailed analyses in order to understand the relation between the thermodynamical properties of fluids and the energy efficiency of refrigerating installations. The efficiency depends entirely on the global design of the installation while the choice of the fluid is only one element that contributes to this efficiency. This paper analyzes successively: the consequences of pure refrigerant substitution on volume and centrifugal compressors, and the constraints linked with the use of mixtures close to azeotropic compounds (R408A and R404A) and mixtures with temperature shift like R407C. In this last case, the replacement is deeply different in the case of water heat exchangers and in the case of air-circulation heat exchangers. (J.S.) 3 refs.

  18. Cerebrospinal fluid endorphins in schizophrenia

    International Nuclear Information System (INIS)

    Rimon, R.; Terenius, L.; Kampman, R.

    1980-01-01

    Opioid-receptor-active material, endorphins, has been measured in cerebrospinal fluid samples obtained from schizophrenics. A chromatographic procedure isolated the Fraction I endorphin which was quantitated in a receptorassay. At least two cerebrospinal fluid samples were obtained from each patient, at day 0 with no medication and at days 30 and 60 after medication with fluphenazine under standardized conditions. Three series of patients were included: acute schizophrenics (n=11); re-entry schizophrenics (n=7) who have previously been treated with neuroleptics but were readmitted to hospital usually as a consequence of stopped medication, and chronic schizophrenics (n=9) who had been without neuroleptics for at least 2 weeks prior to day 0. At day 0, 6/9 acute cases, 4/6 of re-entry and 2/9 chronic cases had endorphin levels above the range of healthy volunteers. The levels in chronic cases were significantly lower than those in acute cases. Treatment with neuroleptics significantly lowered the endorphin levels in acute cases. These results confirm and extend previous observations. (author)

  19. A dynamic neutral fluid model for the PIC scheme

    Science.gov (United States)

    Wu, Alan; Lieberman, Michael; Verboncoeur, John

    2010-11-01

    Fluid diffusion is an important aspect of plasma simulation. A new dynamic model is implemented using the continuity and boundary equations in OOPD1, an object oriented one-dimensional particle-in-cell code developed at UC Berkeley. The model is described and compared with analytical methods given in [1]. A boundary absorption parameter can be adjusted from ideal absorption to ideal reflection. Simulations exhibit good agreement with analytic time dependent solutions for the two ideal cases, as well as steady state solutions for mixed cases. For the next step, fluid sources and sinks due to particle-particle or particle-fluid collisions within the simulation volume and to surface reactions resulting in emission or absorption of fluid species will be implemented. The resulting dynamic interaction between particle and fluid species will be an improvement to the static fluid in the existing code. As the final step in the development, diffusion for multiple fluid species will be implemented. [4pt] [1] M.A. Lieberman and A.J. Lichtenberg, Principles of Plasma Discharges and Materials Processing, 2nd Ed, Wiley, 2005.

  20. [Clinical study of 12 cases with obstetric mirror syndrome].

    Science.gov (United States)

    Wu, Lin-lin; Wang, Chen-hong; Li, Zhi-quan

    2012-03-01

    To discuss the clinical features, management, pregnancy outcome and prognosis of obstetric mirror syndrome. The clinical data of 12 cases with obstetric mirror syndrome at Shenzhen Maternity and Child Healthcare Hospital from April 2008 to December 2010 were collected to retrospectively analyze the clinical features, management, pregnancy outcome and prognosis. (1) ETIOLOGY: 12 cases with obstetric mirror syndrome included 9 cases of Bart's hydrops fetalis, 2 cases with fetal complicated congenital cardiac anomalies, and 1 case of unknown etiology. (2) Gestational age at diagnosis and at delivery: gestational age at diagnosis ranged from 28 to 36 weeks [mean (31.5 ± 4.7) weeks], and gestational age at delivery ranged from 28(+3) to 38 weeks [mean (32.9 ± 2.9) weeks]. There were no significant differences between the gestational age at diagnosis and at delivery in consistence with severe preeclampsia group and mild preeclampsia group [(31.8 ± 2.3) weeks vs. (30.9 ± 7.2) weeks, (32.5 ± 2.3) weeks vs. (33.5 ± 3.9) weeks, P > 0.05]. (3) The patients with obstetric mirror syndrome can present a preeclampsia-like syndrome: maternal extremity edema in 12 cases, headache and visual disturbance in 1 case, proteinuria in 11 cases, elevated blood pressure in 5 cases, elevated uric acid in 9 cases, hypoproteinemia in 12 cases, elevated creatinine in 3 case, elevated liver enzyme in 1 case, thrombocytopenia in 2 cases. The major complications included 1 case of HELLP syndrome, acute pulmonary edema, placental abruption, amnionic fluid embolism, DIC respectively, 3 cases of acute kidney failure and 6 cases of postpartum hemorrhage. (4) Sonographic findings: 1) Hydrops fetalis: fetal ultrasound revealed pleural fluid, fetal ascites, skin edema, scalp edema, encephalocolele enlargement, hydropericardium and increased cardio-chest ratio. 2) Placenta megaly: the placental pathological examination revealed edematous and large in 12 cases. Placental thickness was beyond 4 cm in

  1. A blended learning approach to teach fluid mechanics in engineering

    Science.gov (United States)

    Rahman, Ataur

    2017-05-01

    This paper presents a case study on the teaching and learning of fluid mechanics at the University of Western Sydney (UWS), Australia, by applying a blended learning approach (BLA). In the adopted BLA, various flexible learning materials have been made available to the students such as online recorded lectures, online recorded tutorials, hand written tutorial solutions, discussion board and online practice quizzes. The lecture and tutorial class times have been primarily utilised to discuss confusing topics and engage students with practical issues in applying the theories learnt in fluid mechanics. Based on the data of over 734 students over a 4-year period, it has been shown that a BLA has improved the learning experience of the fluid mechanics students in UWS. The overall percentage of student satisfaction in this subject has increased by 18% in the BLA case compared with the traditional one.

  2. Leukocyte-derived microparticles and scanning electron microscopic structures in two fractions of fresh cerebrospinal fluid in amyotrophic lateral sclerosis: a case report

    Directory of Open Access Journals (Sweden)

    Zachau Anne C

    2012-09-01

    Full Text Available Abstract Introduction Amyotrophic lateral sclerosis is a progressive neurodegenerative disorder characterized by degeneration of motoneuron cells in anterior spinal horns. There is a need for early and accurate diagnosis with this condition. In this case report we used two complementary methods: scanning electron microscopy and fluorescence-activated cell sorting. This is the first report to our knowledge of microparticles in the cerebrospinal fluid of a patient with amyotrophic lateral sclerosis. Case presentation An 80-year-old Swedish man of Caucasian ethnicity presented to our facility with symptoms of amyotrophic lateral sclerosis starting a year before his first hospital examination, such as muscle weakness and twitching in his right hand progressing to arms, body and leg muscles. Electromyography showed classical neurophysiological findings of amyotrophic lateral sclerosis. Routine blood sample results were normal. A lumbar puncture was performed as a routine investigation and his cerebrospinal fluid was normal with regard to cell count and protein levels, and there were no signs of inflammation. However, scanning electron microscopy and fluorescence-activated cell sorting showed pronounced abnormalities compared to healthy controls. Flow cytometry analysis of two fractions of cerebrospinal fluid from our patient with amyotrophic lateral sclerosis was used to measure the specific binding of antibodies to CD42a, CD144 and CD45, and of phosphatidylserine to lactadherin. Our patient displayed over 100 times more phosphatidylserine-positive microparticles and over 400 times more cell-derived microparticles of leukocyte origin in his cerebrospinal fluid compared to healthy control subjects. The first cerebrospinal fluid fraction contained about 50% more microparticles than the second fraction. The scanning electron microscopy filters used with cerebrospinal fluid from our patient were filled with compact aggregates of spherical particles of

  3. Thermodynamics of Fluid Polyamorphism

    Directory of Open Access Journals (Sweden)

    Mikhail A. Anisimov

    2018-01-01

    Full Text Available Fluid polyamorphism is the existence of different condensed amorphous states in a single-component fluid. It is either found or predicted, usually at extreme conditions, for a broad group of very different substances, including helium, carbon, silicon, phosphorous, sulfur, tellurium, cerium, hydrogen, and tin tetraiodide. This phenomenon is also hypothesized for metastable and deeply supercooled water, presumably located a few degrees below the experimental limit of homogeneous ice formation. We present a generic phenomenological approach to describe polyamorphism in a single-component fluid, which is completely independent of the molecular origin of the phenomenon. We show that fluid polyamorphism may occur either in the presence or in the absence of fluid phase separation depending on the symmetry of the order parameter. In the latter case, it is associated with a second-order transition, such as in liquid helium or liquid sulfur. To specify the phenomenology, we consider a fluid with thermodynamic equilibrium between two distinct interconvertible states or molecular structures. A fundamental signature of this concept is the identification of the equilibrium fraction of molecules involved in each of these alternative states. However, the existence of the alternative structures may result in polyamorphic fluid phase separation only if mixing of these structures is not ideal. The two-state thermodynamics unifies all the debated scenarios of fluid polyamorphism in different areas of condensed-matter physics, with or without phase separation, and even goes beyond the phenomenon of polyamorphism by generically describing the anomalous properties of fluids exhibiting interconversion of alternative molecular states.

  4. Fluid mechanics. Vol. 2

    International Nuclear Information System (INIS)

    Truckenbrodt, E.

    1980-01-01

    The second volume contains the chapter 4 to 6. Whereas chapter 1 deals with the introduction into the mechanics of fluids and chapter 2 with the fundamental laws of fluid and thermal fluid dynamics, in chapter 3 elementary flow phenomena in fluids with constant density are treated. Chapter 4 directly continues chapter 3 and describes elementary flow phenomena in fluids with varying density. Fluid statics again is treated as a special case. If compared with the first edition the treatment of unsteady laminar flow and of pipe flow for a fluid with varying density were subject to a substantial extension. In chapter 5 rotation-free and rotating potential flows are presented together. By this means it is achieved to explain the behaviour of the multidimensional fictionless flow in closed form. A subchapter describes some related problems of potential theory like the flow along a free streamline and seepage flow through a porous medium. The boundary layer flows in chapter 6 are concerned with the flow and temperature boundary layer in laminar and turbulent flows at a fired wall. In it differential and integral methods are applied of subchapter reports on boundary layer flows without a fixed boundary, occurring e.g. in an open jet and in a wake flow. The problems of intermittence and of the Coanda effect are briefly mentioned. (orig./MH)

  5. Personalised fluid resuscitation in the ICU: still a fluid concept?

    Science.gov (United States)

    van Haren, Frank

    2017-12-28

    The administration of intravenous fluid to critically ill patients is one of the most common, but also one of the most fiercely debated, interventions in intensive care medicine. Even though many thousands of patients have been enrolled in large trials of alternative fluid strategies, consensus remains elusive and practice is widely variable. Critically ill patients are significantly heterogeneous, making a one size fits all approach unlikely to be successful.New data from basic, animal, and clinical research suggest that fluid resuscitation could be associated with significant harm. There are several important limitations and concerns regarding fluid bolus therapy as it is currently being used in clinical practice. These include, but are not limited to: the lack of an agreed definition; limited and short-lived physiological effects; no evidence of an effect on relevant patient outcomes; and the potential to contribute to fluid overload, specifically when fluid responsiveness is not assessed and when targets and safety limits are not used.Fluid administration in critically ill patients requires clinicians to integrate abnormal physiological parameters into a clinical decision-making model that also incorporates the likely diagnosis and the likely risk or benefit in the specific patient's context. Personalised fluid resuscitation requires careful attention to the mnemonic CIT TAIT: context, indication, targets, timing, amount of fluid, infusion strategy, and type of fluid.The research agenda should focus on experimental and clinical studies to: improve our understanding of the physiological effects of fluid infusion, e.g. on the glycocalyx; evaluate new types of fluids; evaluate novel fluid minimisation protocols; study the effects of a no-fluid strategy for selected patients and scenarios; and compare fluid therapy with other interventions. The adaptive platform trial design may provide us with the tools to evaluate these types of interventions in the intrinsically

  6. On Computational Fluid Dynamics Tools in Architectural Design

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Hougaard, Mads; Stærdahl, Jesper Winther

    engineering computational fluid dynamics (CFD) simulation program ANSYS CFX and a CFD based representative program RealFlow are investigated. These two programs represent two types of CFD based tools available for use during phases of an architectural design process. However, as outlined in two case studies...

  7. Liberal Versus Restrictive Fluid Management in Knee Arthroplasty: A Randomized, Double-Blind Study

    DEFF Research Database (Denmark)

    Holte, Kathrine; Kristensen, Billy Bjarne; Valentiner, Lotte

    2007-01-01

    BACKGROUND: There are few data describing the relationship between amount of perioperative fluid and organ function. In this study we investigated the effects of two levels of intravascular fluid administration ("liberal" versus "restrictive") in knee arthroplasty on physiological recovery...... with a standardized volume of colloid. All other aspects of perioperative management (including anesthesia, preoperative fluid status, and postoperative management) were standardized. Primary outcome variables included pulmonary function (spirometry), exercise capacity ("timed up and go" test), coagulation...... as the primary outcome variable. METHODS: In a double-blind study, 48 ASA I-III patients undergoing fast-track elective knee arthroplasty were randomized to restrictive or liberal perioperative intravascular fluid administration. Patients received a fixed rate infusion of Ringer's lactate solution...

  8. Open-Source Software in Computational Research: A Case Study

    Directory of Open Access Journals (Sweden)

    Sreekanth Pannala

    2008-04-01

    Full Text Available A case study of open-source (OS development of the computational research software MFIX, used for multiphase computational fluid dynamics simulations, is presented here. The verification and validation steps required for constructing modern computational software and the advantages of OS development in those steps are discussed. The infrastructure used for enabling the OS development of MFIX is described. The impact of OS development on computational research and education in gas-solids flow, as well as the dissemination of information to other areas such as geophysical and volcanology research, is demonstrated. This study shows that the advantages of OS development were realized in the case of MFIX: verification by many users, which enhances software quality; the use of software as a means for accumulating and exchanging information; the facilitation of peer review of the results of computational research.

  9. Soft particles at a fluid interface

    Science.gov (United States)

    Mehrabian, Hadi; Harting, Jens; Snoeijer, Jacco H.

    2015-11-01

    Particles added to a fluid interface can be used as a surface stabilizer in the food, oil and cosmetic industries. As an alternative to rigid particles, it is promising to consider highly deformable particles that can adapt their conformation at the interface. In this study, we compute the shapes of soft elastic particles using molecular dynamics simulations of a cross-linked polymer gel, complemented by continuum calculations based on the linear elasticity. It is shown that the particle shape is not only affected by the Young's modulus of the particle, but also strongly depends on whether the gel is partially or completely wetting the fluid interface. We find that the molecular simulations for the partially wetting case are very accurately described by the continuum theory. By contrast, when the gel is completely wetting the fluid interface the linear theory breaks down and we reveal that molecular details have a strong influence on the equilibrium shape.

  10. Fluid-structure interaction investigations for pipelines

    International Nuclear Information System (INIS)

    Altstadt, E.; Carl, H.; Weiss, R.

    2003-12-01

    In existing Nuclear Power Plants water hammers can occur in case of an inflow of sub-cooled water into pipes or other parts of the equipment, which are filled with steam or steam-water mixture. They also may appear as the consequence of fast valve closing or opening actions or of breaks in pipelines, with single phase or two-phase flow. In the latter case, shock waves in two-phase flow must be expected. In all cases, strong dynamic stresses are induced in the wall of the equipment. Further, the change of the momentum of the liquid motion and the deformation of the component due to the dynamic stresses generate high loads on the support structures of the component, in which the water hammer respectively the shock wave occurs. The influence of the fluid-structure interaction on the magnitude of the loads on pipe walls and support structures is not yet completely understood. In case of a dynamic load caused by a pressure wave, the stresses in pipe walls, especially in bends, are different from the static case. The propagating pressure wave may cause additional non-symmetric deformations which increase the equivalent stresses in comparison to the symmetric load created by a static inner pressure. On the other hand, fluid-structure interaction causes the structure to deform, which leads to a decrease of the resulting stresses. The lack of experimental data obtained at well defined geometric boundary conditions is a significant obstacle for the validation of codes which consider fluid-structure interaction. Furthermore, up to now the feedback from structural deformations to the fluid mechanics has not been fully implemented in existing calculation software codes. Therefore, at FZR a cold water hammer test facility (CWHTF) was designed and built up. (orig.)

  11. Contracting bubbles in Hele-Shaw cells with a power-law fluid

    International Nuclear Information System (INIS)

    McCue, Scott W; King, John R

    2011-01-01

    The problem of bubble contraction in a Hele-Shaw cell is studied for the case in which the surrounding fluid is of power-law type. A small perturbation of the radially symmetric problem is first considered, focussing on the behaviour just before the bubble vanishes, it being found that for shear-thinning fluids the radially symmetric solution is stable, while for shear-thickening fluids the aspect ratio of the bubble boundary increases. The borderline (Newtonian) case considered previously is neutrally stable, the bubble boundary becoming elliptic in shape with the eccentricity of the ellipse depending on the initial data. Further light is shed on the bubble contraction problem by considering a long thin Hele-Shaw cell: for early times the leading-order behaviour is one-dimensional in this limit; however, as the bubble contracts its evolution is ultimately determined by the solution of a Wiener–Hopf problem, the transition between the long thin limit and the extinction limit in which the bubble vanishes being described by what is in effect a similarity solution of the second kind. This same solution describes the generic (slit-like) extinction behaviour for shear-thickening fluids, the interface profiles that generalize the ellipses that characterize the Newtonian case being constructed by the Wiener–Hopf calculation

  12. Modelling of Mass Transfer Phenomena in Chemical and Biochemical Reactor Systems using Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Larsson, Hilde Kristina

    the velocity and pressure distributions in a fluid. CFD also enables the modelling of several fluids simultaneously, e.g. gas bubbles in a liquid, as well as the presence of turbulence and dissolved chemicals in a fluid, and many other phenomena. This makes CFD an appreciated tool for studying flow structures......, mixing, and other mass transfer phenomena in chemical and biochemical reactor systems. In this project, four selected case studies are investigated in order to explore the capabilities of CFD. The selected cases are a 1 ml stirred microbioreactor, an 8 ml magnetically stirred reactor, a Rushton impeller...... and an ion-exchange reaction are also modelled and compared to experimental data. The thesis includes a comprehensive overview of the fundamentals behind a CFD software, as well as a more detailed review of the fluid dynamic phenomena investigated in this project. The momentum and continuity equations...

  13. Structural studies of fluid mercury using synchrotron radiation at SPring-8

    International Nuclear Information System (INIS)

    Hong Xinguo; Tamura, K.

    2003-01-01

    With the volume expansion by heating up toward the critical point, typical liquid metal mercury undergoes metal-nonmetal transition (M-NM) at a density around 9 g/cm 3 . To study the structure changes of fluid Hg during volume expansion, we have carried out X-ray diffraction measurements for expanded fluid mercury in a wide density region from liquid to dense vapour region using synchrotron radiation at SPring-8. We have succeeded in developing a new high-pressure vessel, up to 1700 degree C under 2000 bar and with 7 scattering windows for energy-dispersive X-ray diffraction (EDXD) measurements under high temperature and high pressure. It was found that the reliability of the structure factors, S(k), and the accuracy of the pair distribution functions, g(r), are much better. Reliable relations of the coordination number and the correlation distance with the density of fluid Hg were obtained. Structural model of volume expansion of fluid Hg is proposed based on our new results. Structural changes with decreasing density are discussed in relation to the M-NM transition in fluid Hg

  14. Interface behavior of a multi-layer fluid configuration subject to acceleration in a microgravity environment, supplement 1. M.S. Thesis

    Science.gov (United States)

    Lyell, M. J.; Roh, Michael

    1991-01-01

    With the increasing opportunities for research in a microgravity environment, there arises a need for understanding fluid mechanics under such conditions. In particular, a number of material processing configurations involve fluid-fluid interfaces which may experience instabilities in the presence of external forcing. In a microgravity environment, these accelerations may be periodic or impulse-type in nature. This research investigates the behavior of a multi-layer idealized fluid configuration which is infinite in extent. The analysis is linear, and each fluid region is considered inviscid, incompressible, and immiscible. An initial parametric study of confiquration stability in the presence of a constant acceleration field is performed. The zero mean gravity limit case serves as the base state for the subsequent time-dependent forcing cases. A stability analysis of the multi-layer fluid system in the presence of periodic forcing is investigated. Floquet theory is utilized. A parameter study is performed, and regions of stability are identified. For the impulse-type forcing case, asymptotic stability is established for the configuration. Using numerical integration, the time response of the interfaces is determined.

  15. Imaging techniques applied to the study of fluids in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Tomutsa, L.; Doughty, D.; Mahmood, S.; Brinkmeyer, A.; Madden, M.P.

    1991-01-01

    A detailed understanding of rock structure and its influence on fluid entrapment, storage capacity, and flow behavior can improve the effective utilization and design of methods to increase the recovery of oil and gas from petroleum reservoirs. The dynamics of fluid flow and trapping phenomena in porous media was investigated. Miscible and immiscible displacement experiments in heterogeneous Berea and Shannon sandstone samples were monitored using X-ray computed tomography (CT scanning) to determine the effect of heterogeneities on fluid flow and trapping. The statistical analysis of pore and pore throat sizes in thin sections cut from these sandstone samples enabled the delineation of small-scale spatial distributions of porosity and permeability. Multiphase displacement experiments were conducted with micromodels constructed using thin slabs of the sandstones. The combination of the CT scanning, thin section, and micromodel techniques enables the investigation of how variations in pore characteristics influence fluid front advancement, fluid distributions, and fluid trapping. Plugs cut from the sandstone samples were investigated using high resolution nuclear magnetic resonance imaging permitting the visualization of oil, water or both within individual pores. The application of these insights will aid in the proper interpretation of relative permeability, capillary pressure, and electrical resistivity data obtained from whole core studies. 7 refs., 14 figs., 2 tabs.

  16. A systems approach to theoretical fluid mechanics: Fundamentals

    Science.gov (United States)

    Anyiwo, J. C.

    1978-01-01

    A preliminary application of the underlying principles of the investigator's general system theory to the description and analyses of the fluid flow system is presented. An attempt is made to establish practical models, or elements of the general fluid flow system from the point of view of the general system theory fundamental principles. Results obtained are applied to a simple experimental fluid flow system, as test case, with particular emphasis on the understanding of fluid flow instability, transition and turbulence.

  17. Analytical study of the non orthogonal stagnation point flow of a micro polar fluid

    Directory of Open Access Journals (Sweden)

    M. Ali. Abbas

    2017-01-01

    Full Text Available In this paper we consider the steady two dimensional flow of micro polar fluids on a flat plate. The flow under discussion is the modified Hiemenz flow for a micro polar fluid which occurs in the hjkns + skms boundary layer near an orthogonal stagnation point. The full governing equation reduced to a modified Hiemenz flow. The solution to the boundary value problem is governed by two non dimensional parameters, the material parameter K and the ratio of the micro rotation to skin friction parameter n. The obtained nonlinear coupled ordinary differential equations are solved by using the Homotopy perturbation method. Comparison between numerical and analytical solutions of the problem is shown in tables form for different values of the governing parameters K and n. Effects of the material parameter K on the velocity profile and microrotation profiles for different cases of n are discussed graphically as well as numerically. Velocity profile decreases as the material parameter K increases and the microrotation profile increases as the material parameter K increases for different cases of n.

  18. Fluid analog model for boundary effects in field theory

    International Nuclear Information System (INIS)

    Ford, L. H.; Svaiter, N. F.

    2009-01-01

    Quantum fluctuations in the density of a fluid with a linear phonon dispersion relation are studied. In particular, we treat the changes in these fluctuations due to nonclassical states of phonons and to the presence of boundaries. These effects are analogous to similar effects in relativistic quantum field theory, and we argue that the case of the fluid is a useful analog model for effects in field theory. We further argue that the changes in the mean squared density are, in principle, observable by light scattering experiments.

  19. Fluid inclusion geothermometry

    Science.gov (United States)

    Cunningham, C.G.

    1977-01-01

    Fluid inclusions trapped within crystals either during growth or at a later time provide many clues to the histories of rocks and ores. Estimates of fluid-inclusion homogenization temperature and density can be obtained using a petrographic microscope with thin sections, and they can be refined using heating and freezing stages. Fluid inclusion studies, used in conjunction with paragenetic studies, can provide direct data on the time and space variations of parameters such as temperature, pressure, density, and composition of fluids in geologic environments. Changes in these parameters directly affect the fugacity, composition, and pH of fluids, thus directly influencing localization of ore metals. ?? 1977 Ferdinand Enke Verlag Stuttgart.

  20. Numerical study of magnetic field effect on nano-fluid forced convection in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Heidary, H., E-mail: Heidary_ha@aut.ac.ir [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran (Iran, Islamic Republic of); Hosseini, R. [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran (Iran, Islamic Republic of); Pirmohammadi, M., E-mail: Pirmohamadi@pardisiau.ac.ir [Department of Mechanical Engineering, Pardis Branch, Islamic Azad University, Pardis New City, Tehran (Iran, Islamic Republic of); Kermani, M.J. [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran (Iran, Islamic Republic of)

    2015-01-15

    In this study heat transfer and fluid flow analysis in a straight channel utilizing nano-fluid is numerically studied, while flow field is under magnetic field. Usage of nano-particles in base fluid and also applying magnetic field transverse to fluid velocity are two ways recommended in this paper to enhance heat exchange in straight duct. The fluid temperature at the channel inlet (T{sub in}) is taken less than that of the walls (T{sub w}). With assuming thermal equilibrium state of both the fluid phase and nano-particles and ignoring the slip velocity between the phases, single phase approach is used for modeling of nano-fluid. The governing equations are numerically solved in the domain by the control volume approach based on the SIMPLE technique. Numerical studies are performed over a range of Reynolds number, nano-fluid volume fraction and Hartmann number. The influence of these parameters is investigated on the local and average Nusselt numbers. Computations show excellent agreement with the literature. From this study, it is concluded that heat transfer in channels can enhance up to 75% due to the presence of nano-particles and magnetic field in channels. In industrial applications for cooling or heating purposes, the recommended ways in this paper, can provide helpful guidelines to the manufacturers to enhance efficiencies without heat exchanger area increase. - Highlights: • Addition of 10% nano-particles (copper here) can enhance the heat exchange by 26%. • Presence of magnetic field with Ha=30 in pure fluid can enhance the heat exchange by 50%. • Presence of magnetic field and nanofluid with Ha=30 and ϕ=0.1, can enhance the heat exchange by 76%. • Increasing Re{sub H} from 50 to 1000, the average Nu number can increase by a factor of ≈3.

  1. Pressure-temperature-fluid constraints for the Emmaville-Torrington emerald deposit, New South Wales, Australia: Fluid inclusion and stable isotope studies

    Science.gov (United States)

    Loughrey, Lara; Marshall, Dan; Jones, Peter; Millsteed, Paul; Main, Arthur

    2012-06-01

    The Emmaville-Torrington emeralds were first discovered in 1890 in quartz veins hosted within a Permian metasedimentary sequence, consisting of meta-siltstones, slates and quartzites intruded by pegmatite and aplite veins from the Moule Granite. The emerald deposit genesis is consistent with a typical granite-related emerald vein system. Emeralds from these veins display colour zonation alternating between emerald and clear beryl. Two fluid inclusion types are identified: three-phase (brine+vapour+halite) and two-phase (vapour+liquid) fluid inclusions. Fluid inclusion studies indicate the emeralds were precipitated from saline fluids ranging from approximately 33 mass percent NaCl equivalent. Formational pressures and temperatures of 350 to 400 °C and approximately 150 to 250 bars were derived from fluid inclusion and petrographic studies that also indicate emerald and beryl precipitation respectively from the liquid and vapour portions of a two-phase (boiling) system. The distinct colour zonations observed in the emerald from these deposits is the first recorded emerald locality which shows evidence of colour variation as a function of boiling. The primary three-phase and primary two-phase FITs are consistent with alternating chromium-rich `striped' colour banding. Alternating emerald zones with colourless beryl are due to chromium and vanadium partitioning in the liquid portion of the boiling system. The chemical variations observed at Emmaville-Torrington are similar to other colour zoned emeralds from other localities worldwide likely precipitated from a boiling system as well.

  2. Geochemical Signature of Magmatic-Hydrothermal Fluids Exsolved from the Beauvoir Rare-Metal Granite (Massif Central, France: Insights from LA-ICPMS Analysis of Primary Fluid Inclusions

    Directory of Open Access Journals (Sweden)

    Matthieu Harlaux

    2017-01-01

    Full Text Available The Beauvoir granite (Massif Central, France represents an exceptional case in the European Variscan belt of a peraluminous rare-metal granite crosscutting an early W stockwork. The latter was strongly overprinted by rare-metal magmatic-hydrothermal fluids derived from the Beauvoir granite, resulting in a massive topazification of the quartz-ferberite vein system. This work presents a complete study of primary fluid inclusions hosted in quartz and topaz from the Beauvoir granite and the metasomatized stockwork, in order to characterize the geochemical composition of the magmatic fluids exsolved during the crystallization of this evolved rare-metal peraluminous granite. Microthermometric and Raman spectrometry data show that the earliest fluid (L1 is of high temperature (500 to >600°C, high salinity (17–28 wt.% NaCl eq, and Li-rich (Te100 m and interaction with external fluids.

  3. Correlation of supercritical-fluid extraction recoveries with supercritical-fluid chromatographic retention data: A fundamental study

    NARCIS (Netherlands)

    Lou, X.W.; Janssen, J.G.M.; Cramers, C.A.M.G.

    1995-01-01

    The possibility of using supercritical-fluid chromatographic retention data for examining the effects of operational parameters, such as pressure and flow rate, on the extraction characteristics in supercritical-fluid extraction (SFE) was investigated. A model was derived for calculating the

  4. Fluid Overload and Cumulative Thoracostomy Output Are Associated With Surgical Site Infection After Pediatric Cardiothoracic Surgery.

    Science.gov (United States)

    Sochet, Anthony A; Nyhan, Aoibhinn; Spaeder, Michael C; Cartron, Alexander M; Song, Xiaoyan; Klugman, Darren; Brown, Anna T

    2017-08-01

    To determine the impact of cumulative, postoperative thoracostomy output, amount of bolus IV fluids and peak fluid overload on the incidence and odds of developing a deep surgical site infection following pediatric cardiothoracic surgery. A single-center, nested, retrospective, matched case-control study. A 26-bed cardiac ICU in a 303-bed tertiary care pediatric hospital. Cases with deep surgical site infection following cardiothoracic surgery were identified retrospectively from January 2010 through December 2013 and individually matched to controls at a ratio of 1:2 by age, gender, Risk Adjustment for Congenital Heart Surgery score, Society of Thoracic Surgeons-European Association for Cardiothoracic Surgery category, primary cardiac diagnosis, and procedure. None. Twelve cases with deep surgical site infection were identified and matched to 24 controls without detectable differences in perioperative clinical characteristics. Deep surgical site infection cases had larger thoracostomy output and bolus IV fluid volumes at 6, 24, and 48 hours postoperatively compared with controls. For every 1 mL/kg of thoracostomy output, the odds of developing a deep surgical site infection increase by 13%. By receiver operative characteristic curve analysis, a cutoff of 49 mL/kg of thoracostomy output at 48 hours best discriminates the development of deep surgical site infection (sensitivity 83%, specificity 83%). Peak fluid overload was greater in cases than matched controls (12.5% vs 6%; p operative characteristic curve analysis, a threshold value of 10% peak fluid overload was observed to identify deep surgical site infection (sensitivity 67%, specificity 79%). Conditional logistic regression of peak fluid overload greater than 10% on the development of deep surgical site infection yielded an odds ratio of 9.4 (95% CI, 2-46.2). Increased postoperative peak fluid overload and cumulative thoracostomy output were associated with deep surgical site infection after pediatric

  5. Numerical investigation of fluid mud motion using a three-dimensional hydrodynamic and two-dimensional fluid mud coupling model

    Science.gov (United States)

    Yang, Xiaochen; Zhang, Qinghe; Hao, Linnan

    2015-03-01

    A water-fluid mud coupling model is developed based on the unstructured grid finite volume coastal ocean model (FVCOM) to investigate the fluid mud motion. The hydrodynamics and sediment transport of the overlying water column are solved using the original three-dimensional ocean model. A horizontal two-dimensional fluid mud model is integrated into the FVCOM model to simulate the underlying fluid mud flow. The fluid mud interacts with the water column through the sediment flux, current, and shear stress. The friction factor between the fluid mud and the bed, which is traditionally determined empirically, is derived with the assumption that the vertical distribution of shear stress below the yield surface of fluid mud is identical to that of uniform laminar flow of Newtonian fluid in the open channel. The model is validated by experimental data and reasonable agreement is found. Compared with numerical cases with fixed friction factors, the results simulated with the derived friction factor exhibit the best agreement with the experiment, which demonstrates the necessity of the derivation of the friction factor.

  6. Protein profiling reveals inter-individual protein homogeneity of arachnoid cyst fluid and high qualitative similarity to cerebrospinal fluid

    Directory of Open Access Journals (Sweden)

    Berle Magnus

    2011-05-01

    the majority of abundant proteins in AC fluid also can be found in CSF. Compared to plasma, as many as 104 proteins in AC were not found in the list of 3017 plasma proteins. Conclusions Based on the protein content of AC fluid, our data indicate that temporal AC is a homogenous condition, pointing towards a similar AC filling mechanism for the 14 patients examined. Most of the proteins identified in AC fluid have been identified in CSF, indicating high similarity in the qualitative protein content of AC to CSF, whereas this was not the case between AC and plasma. This indicates that AC is filled with a liquid similar to CSF. As far as we know, this is the first proteomics study that explores the AC fluid proteome.

  7. Hyperacid volcano-hydrothermal fluids from Copahue volcano, Argentina: Analogs for "subduction zone fluids"?

    Science.gov (United States)

    Varekamp, J. C.

    2007-12-01

    Hyperacid concentrated Chlorine-Sulfate brines occur in many young arc volcanoes, with pH values Copahue volcanic system (Argentina) suggest reservoir temperatures of 175-300 oC, whereas the surface fluids do not exceed local boiling temperatures. These fluids are generated at much lower P-T conditions than fluids associated with a dehydrating subducted sediment complex below arc volcanoes, but their fundamental chemical compositions may have similarities. Incompatible trace element, major element concentrations and Pb isotope compositions of the fluids were used to determine the most likely rock protoliths for these fluids. Mean rock- normalized trace element diagrams then indicate which elements are quantitatively extracted from the rocks and which are left behind or precipitated in secondary phases. Most LILE show flat rock-normalized patterns, indicating close to congruent dissolution, whereas Ta-Nb-Ti show strong depletions in the rock-normalized diagrams. These HFSE are either left behind in the altered rock protolith or were precipitated along the way up. The behavior of U and Th is almost identical, suggesting that in these low pH fluids with abundant ligands Th is just as easily transported as U, which is not the case in more dilute, neutral fluids. Most analyzed fluids have steeper LREE patterns than the rocks and have negative Eu anomalies similar to the rocks. Fluids that interacted with newly intruded magma e.g., during the 2000 eruption, have much less pronounced Eu anomalies, which was most likely caused by the preferential dissolution of plagioclase when newly intruded magma interacted with the acid fluids. The fluids show a strong positive correlation between Y and Cd (similar to MORB basalts, Yi et al., JGR, 2000), suggesting that Cd is mainly a rock-derived element that may not show chalcophilic behavior. The fluids are strongly enriched (relative to rock) in As, Zn and Pb, suggesting that these elements were carried with the volcanic gas phase

  8. Potential of organic Rankine cycle technology in India: Working fluid selection and feasibility study

    International Nuclear Information System (INIS)

    Sarkar, Jahar; Bhattacharyya, Souvik

    2015-01-01

    India has great potential to employ the ORC (organic Rankine cycle) technology for conversion of low temperature waste heat and renewable energy. In this study, available waste heat and relevant renewable heat sources in India are reviewed and suitable working fluids for ORC have been selected based on operational, environmental and safety criteria. A feasibility study and comparison of selected fluids for ORC is also presented for Indian climates along with discussions on component, operation and cost related aspects. A comprehensive review on available heat sources and sinks shows that India has plenty of waste heat and renewable energy sources for electricity generation by means of ORC; however, condenser operation may be challenging due to wide ambient temperature variation. Appropriate performance comparison among selected working fluids shows that ammonia is the best fluid in terms of net power generation and compactness of turbo-machineries, whereas n-Pentane is the best fluid in terms of thermal efficiency and heat exchanger compactness. Both are recommended as working fluids for ORC installations in India. The study reveals that there is a great opportunity to employ this technology in India provided we have to overcome some challenges related to component selection, finance and maintenance. - Highlights: • Available waste heat and renewable heat energies, and sinks in India are reviewed. • Suitable working fluids are selected by operational, environmental and safety criteria. • A feasibility study and comparison of selected fluids are presented for Indian climates. • Ammonia and n-Pentane are recommended for ORC installation in India. • Challenges related to plant component, operation and cost are discussed.

  9. A case study in flow assurance of a pipeline-riser system using OLGA

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Rafael Horschutz; Balino, Jorge Luis [Nucleo de Dinamica e Fluidos. Dept. de Engenharia Mecanica. Universidade de Sao Paulo (EP/USP), SP (Brazil)], e-mails: rafael.nemoto@usp.br, jlbalino@usp.br; Tanaka, Rafael Loureiro; Godinho, Carlos Alberto [Prysmian Cables and Systems, Cariacica, ES (Brazil)], e-mails: rafael.tanaka@prysmian.com, carlos.godinho@prysmian.com

    2010-07-01

    In this paper, a case study in flow assurance is performed considering an offshore operating system, using the software OLGA. As operating system we consider a pipeline-riser geometry with typical dimensions of offshore oil production systems, and a three-phase flow of oil, gas and water. The model developed in OLGA considers the composition and dimensions of the tubes, heat transfer parameters, process equipment and fluid sources. The fluids properties are calculated using the software PVTsim. Simulations are ran in order to determine the pipeline inner diameter and insulation required to satisfy pressure and temperature requirements. It is also possible to simulate the transient behavior of the system, which allows to evaluate if production instabilities are present. In case instabilities exist, two mitigation alternatives are evaluated: closure of a choke valve before the separator and gas lift. Considering a possible production shutdown, the tubes insulation is calculated in order to avoid hydrate formation. (author)

  10. Urinary Analysis of Fluid Retention in the General Population: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Robert G Hahn

    Full Text Available Renal conservation (retention of fluid might affect the outcome of hospital care and can be indicated by increased urinary concentrations of metabolic waste products. We obtained a reference material for further studies by exploring the prevalence of fluid retention in a healthy population.Spot urine sampling was performed in 300 healthy hospital workers. A previously validated algorithm summarized the urine-specific gravity, osmolality, creatinine, and color to a fluid retention index (FRI, where 4.0 is the cut-off for fluid retention consistent with dehydration. In 50 of the volunteers, we also studied the relationships between FRI, plasma osmolality, and water-retaining hormones.The cut-off for fluid retention (FRI ≥ 4.0 was reached by 38% of the population. No correlation was found between the FRI and the time of the day of urine sample collection, and the FRI was only marginally correlated with the time period spent without fluid intake. Volunteers with fluid retention were younger, generally men, and more often had albuminuria (88% vs. 34%, P < 0.001. Plasma osmolality and plasma sodium were somewhat higher in those with a high FRI (mean 294.8 vs. 293.4 mosmol/kg and 140.3 vs. 139.9 mmol/l. Plasma vasopressin was consistently below the limit of detection, and the plasma cortisol, aldosterone, and renin concentrations were similar in subjects with a high or low FRI. The very highest FRI values (≥ 5.0, N = 61 were always accompanied by albuminuria.Fluid retention consistent with moderate dehydration is common in healthy staff working in a Swedish hospital.

  11. Epithelial cells in nipple aspirate fluid and subsequent breast cancer risk: A historic prospective study

    International Nuclear Information System (INIS)

    Baltzell, Kimberly A; Moghadassi, Michelle; Rice, Terri; Sison, Jennette D; Wrensch, Margaret

    2008-01-01

    Past studies have shown that women with abnormal cytology or epithelial cells in nipple aspirate fluid (NAF) have an increased relative risk (RR) of breast cancer when compared to women from whom NAF was attempted but not obtained (non-yielders). This study analyzed NAF results from a group of women seen in a breast clinic between 1970–1991 (N = 2480). Our analysis presented here is an aggregate of two sub-groups: women with questionnaire data (n = 712) and those with NAF visits beginning in 1988 (n = 238), the year in which cancer case information was uniformly collected in California. Cytological classification was determined for a group of 946 women using the most abnormal epithelial cytology observed in fluid specimens. Breast cancer incidence and mortality status was determined through June 2006 using data from the California Cancer Registry, California Vital Statistics and self-report. We estimated odd ratios (ORs) for breast cancer using logistic regression analysis, adjusting for age. We analyzed breast cancer risk related to abnormality of NAF cytology using non-yielders as the referent group and breast cancer risk related to the presence or absence of epithelial cells in NAF, using non-yielders/fluid without epithelial cells as the referent group. Overall, 10% (93) of the 946 women developed breast cancer during the follow-up period. Age-adjusted ORs and 95% confidence intervals (C.I.) compared to non-yielders were 1.4 (0.3 to 6.4), 1.7 (0.9 to 3.5), and 2.0 (1.1 to 3.6) for women with fluid without epithelial cells, normal epithelial cells and hyperplasia/atypia, respectively. Comparing the presence or absence of epithelial cells in NAF, women with epithelial cells present in NAF were more likely to develop breast cancer than non-yielders or women with fluid without epithelial cells (RR = 1.9, 1.2 to 3.1). These results support previous findings that 1) women with abnormal epithelial cells in NAF have an increased risk of breast cancer when compared to

  12. Using FlowLab, an educational computational fluid dynamics tool, to perform a comparative study of turbulence models

    International Nuclear Information System (INIS)

    Parihar, A.; Kulkarni, A.; Stern, F.; Xing, T.; Moeykens, S.

    2005-01-01

    Flow over an Ahmed body is a key benchmark case for validating the complex turbulent flow field around vehicles. In spite of the simple geometry, the flow field around an Ahmed body retains critical features of real, external vehicular flow. The present study is an attempt to implement such a real life example into the course curriculum for undergraduate engineers. FlowLab, which is a Computational Fluid Dynamics (CFD) tool developed by Fluent Inc. for use in engineering education, allows students to conduct interactive application studies. This paper presents a synopsis of FlowLab, a description of one FlowLab exercise, and an overview of the educational experience gained by students through using FlowLab, which is understood through student surveys and examinations. FlowLab-based CFD exercises were implemented into 57:020 Mechanics of Fluids and Transport Processes and 58:160 Intermediate Mechanics of Fluids courses at the University of Iowa in the fall of 2004, although this report focuses only on experiences with the Ahmed body exercise, which was used only in the intermediate-level fluids class, 58:160. This exercise was developed under National Science Foundation funding by the authors of this paper. The focus of this study does not include validating the various turbulence models used for the Ahmed body simulation, because a two-dimensional simplification was applied. With the two-dimensional simplification, students may setup, run, and post process this model in a 50 minute class period using a single-CPU PC, as required for the 58:160 class at the University of Iowa. It is educational for students to understand the implication of a two- dimensional approximation for essentially a three-dimensional flow field, along with the consequent variation in both qualitative and quantitative results. Additionally, through this exercise, students may realize that the choice of the respective turbulence model will affect simulation prediction. (author)

  13. Mathematical well-posedness of a two-fluid equations for bubbly two-phase flows

    International Nuclear Information System (INIS)

    Okawa, Tomio; Kataoka, Isao

    2000-01-01

    It is widely known that two-fluid equations used in most engineering applications do not satisfy the necessary condition for being mathematical well-posed as initial-value problems. In the case of stratified two-phase flows, several researchers have revealed that differential models satisfying the necessary condition are to be derived if the pressure difference between the phases is related to the spatial gradient of the void fraction through the effects of gravity or surface tension. While, in the case of dispersed two-phase flows, no physically reasonable method to derive mathematically well-posed two-fluid model has been proposed. In the present study, particularly focusing on the effect of interfacial pressure terms, we derived the mathematically closed form of the volume-averaged two-fluid model for bubbly two-phase flows. As a result of characteristic analyses, it was shown that the proposed two-fluid equations satisfy the necessary condition of mathematical well-posedness if the void fraction is sufficiently small. (author)

  14. The efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment.

    Science.gov (United States)

    Jang, Ji Hye; Kim, Yu Cheol; Kim, Kwang Soo

    2009-12-01

    This study was designed to evaluate the efficacy of fluid-gas exchange for the treatment of postvitrectomy retinal detachment. We retrospectively reviewed the records of 33 consecutive patients (35 eyes) who underwent fluid-gas exchange treatment for postvitrectomy retinal detachment using the two-needle pars plana approach technique. The retinal reattachment rate was 80.0% after complete intravitreal gas disappearance following the fluid-gas exchange; the overall success rate was 65.7%. Visual acuity was improved or stable in 80.0% of cases; a two-line or greater vision improvement or a best-corrected visual acuity of 0.4 or better occurred in 62.9% of cases. The success rates for superior retinal detachments and posterior pole retinal detachments were 76.5% and 85.7%, respectively. Fluid-gas exchange represents a simple and cost-effective alternative outpatient procedure for retinal reattachment without reoperation for the treatment of superior and posterior pole retinal detachments.

  15. Cytological analysis of bronchoalveolar lavage fluid in the diagnosis of spontaneous respiratory tract disease in dogs: a retrospective study

    International Nuclear Information System (INIS)

    Hawkins, E.C.; DeNicola, D.B.; Plier, M.L.

    1995-01-01

    Results of cytological analysis of bronchoalveolar lavage (BAL) fluid were compared with clinical diagnoses in dogs that presented with signs of respiratory disease to referral hospitals. Of 68 dogs in which a clinical diagnosis was possible, BAL cytological findings were considered definitive for the diagnosis in 17 cases (25%), supportive of the diagnosis in 34 cases (50%), and not helpful in 17 cases (25%). Findings were most often considered supportive of or definitive for the clinical diagnosis in dogs with alveolar or bronchial radiographic patterns, or the presence of pulmonary masses. BAL results among lung lobes differed in 23 of 63 dogs (37%) with diffuse radiographic patterns. Tracheal wash cytology differed from BAL fluid cytology in 45 of 66 dogs (68%). Bronchoalveolar lavage was a clinically useful procedure for the diagnostic evaluation of dogs with signs of respiratory disease

  16. Feasibility study for application of mixture working fluid cycle to nuclear reactor power plant

    International Nuclear Information System (INIS)

    Takeuchi, Yutaka; Ohshima, Iwao; Shiomi, Hirozo; Miyamae, Nobuhiko; Hiramatsu, Miki; Montani, Mitsuto

    1999-01-01

    There exists a large amount of unused energy in nuclear power plants. However, it consists of relatively low temperature energy, so it is difficult to generate electricity by the conventional water-steam cycle. In order to utilize such low temperature energy, we applied a mixture working fluid cycle called as the Kalina cycle to a light water nuclear reactor power plant. The Kalina cycle uses a working fluid composed of ammonia and water to create a variable temperature boiling process. We applied a saturation type Kalina cycle with single stage ammonia-water separation process as a bottoming cycle to a conventional water-steam cycle of a 1100MWe class BWR as an example case. The input heat source is the exhaust or the partial extraction of a low pressure turbine (LPT). A steady state chemical process modeling code ASPENPLUS was used for the sensitivity analyses. The maximum efficiency was calculated to be realized when using the lowest heat sink temperature, 8degC. The additional electrical output is about 95 MWe when using the exhaust of LPT and is about 127 MWe when using the partial extraction of LPT. Namely, about 4.3% of the exhaust heat for the former case and about 5.8% for the latter case can be utilized as electrical power, respectively. (author)

  17. A finite element perturbation method for computing fluid-induced forces on a certrifugal impeller rotating and whirling in a volute casing

    NARCIS (Netherlands)

    Jonker, Jan B.; van Essen, T.G.; van Essen, T.G.

    1997-01-01

    A finite element based method has been developed for computing time-averaged fluid-induced radial excitation forces and rotor dynamic forces on a two-dimensional centrifugal impeller rotating and whirling in a volute casing. In this method potential flow theory is used, which implies the assumption

  18. Magnetohydrodynamic unsteady flow of a Maxwell fluid past a flat plate

    International Nuclear Information System (INIS)

    Khandpur, S.L.; Ravi Kant

    1979-01-01

    A study of the equations describing the flow pattern set up in a linear electrically conducting viscoelastic fluid past an infinite flat plate in the presence of a transverse magnetic field has been made, when the plate is moving parallel to itself with an arbitrary time dependent velocity. The pressure is assumed to be uniform with initial velocity distribution in an exponential form. Operational methods are used to obtain the exact solutions for the velocity profiles. The effects of relaxation parameter of the fluid and magnetic field have been studied. Several particular cases are easily deduced of which two cases: (i) when the plate is moving in its own plane harmonically with time, and (ii) when the velocity of the plate is decaying exponentially with time, are discussed. (auth.)

  19. INFLUENCE OF AMNIOTIC FLUID INDEX ON FOETAL OUTCOME

    Directory of Open Access Journals (Sweden)

    Raja Lakshmi

    2015-03-01

    Full Text Available BACKGROUND AND OBJECTIVE: In these days of smaller families and the obstetrician having to share the onus of giving a healthy child capable of independent existence as well as to ensure that the population is limited for further progress of this developing country, the estimation o f foetal maturity assumes greatest practical importance. As means to achieving the end, estimates of foetal maturity have been done by various clinical and laboratory methods of which assessment of amniotic fluid index assumes importance. The objective is to study the correlation of amniotic fluid index on foetal outcome at term gestation . MATERIALS AND METHODS: The study was carried out on two hundred antenatal women who attended the institute of obstetrics and gynaecology at a Government Hospital for Wome n and Children in Visakhapatnam from Jan 2014 to Jan 2015. It is a comparative prospective study comparing 100 cases of Oligohydramnios (amniotic fluid index 5 cm as control group. RESU LTS : Perinatal outcome was inferred by noting the various parameters and Statistical Analysis was done by applying the chisquare (x2 test and the value of probability was taken . CONCLUSION: The goal of antepartum fetal surveillance is to identify the fetu s at increased risk. Amniotic fluid volume has been proved as an indirect measure of feto - placental function and hence the estimation of amniotic fluid volume assists the obstetrician in risk assessment

  20. Thermal convection of viscoelastic shear-thinning fluids

    International Nuclear Information System (INIS)

    Albaalbaki, Bashar; Khayat, Roger E; Ahmed, Zahir U

    2016-01-01

    The Rayleigh–Bénard convection for non-Newtonian fluids possessing both viscoelastic and shear-thinning behaviours is examined. The Phan-Thien–Tanner (PTT) constitutive equation is implemented to model the non-Newtonian character of the fluid. It is found that while the shear-thinning and viscoelastic effects could annihilate one another for the steady roll flow, presence of both behaviours restricts the roll stability limit significantly compared to the cases when the fluid is either inelastic shear-thinning or purely viscoelastic with constant viscosity. (paper)

  1. Conformal symmetry inheritance in null fluid spacetimes

    International Nuclear Information System (INIS)

    Tupper, B O J; Keane, A J; Hall, G S; Coley, A A; Carot, J

    2003-01-01

    We define inheriting conformal Killing vectors for null fluid spacetimes and find the maximum dimension of the associated inheriting Lie algebra. We show that for non-conformally flat null fluid spacetimes, the maximum dimension of the inheriting algebra is seven and for conformally flat null fluid spacetimes the maximum dimension is eight. In addition, it is shown that there are two distinct classes of non-conformally flat generalized plane wave spacetimes which possess the maximum dimension, and one class in the conformally flat case

  2. Heterogeneous porous media permeability field characterization from fluid displacement data; Integration de donnees de deplacements de fluides dans la caracterisation de milieux poreux heterogenes

    Energy Technology Data Exchange (ETDEWEB)

    Kretz, V.

    2002-11-01

    The prediction of oil recovery or pollutant dispersion requires an accurate knowledge of the permeability field distribution. Available data are usually measurements in well bores, and, since a few years, 4D-seismic data (seismic mappings repeated in time). Such measurements allow to evaluate fluids displacements fronts evolution. The purpose of the thesis is to evaluate the possibility to determinate permeability fields from fluid displacement measurements in heterogeneous porous media. At the laboratory scale, experimental studies are made on a model and on numerical simulations. The system uses blocks of granular materials whose individual geometries and permeabilities are controlled. The fluids displacements are detected with an acoustical. The key parameters of the study are the size and spatial correlation of the permeability heterogeneity distribution, and the influence of viscosity and gravity contrasts between the injected ant displaced fluid. Then the inverse problem - evaluating the permeability field from concentration fronts evolution - is approached. At the reservoir scale, the work will mainly be focused on the integration of 4D-seismic data into inversion programs on a 3D synthetic case. A particular importance will be given to the calculation of gradients, in order to obtain a complementary information about the sensitivity of data. The information provided by 4D-seismic data consists in maps showing the vertical average of oil saturation or the presence of gas. The purpose is to integrate this qualitative information in the inversion process and to evaluate the impact on the reservoir characterization. Comparative studies - with or without 4D-seismic data - will be realized on a synthetic case. (author)

  3. Curvature Dependence of Interfacial Properties for Associating Lennard—Jones Fluids: A Density Functional Study

    International Nuclear Information System (INIS)

    Sun Zong-Li; Kang Yan-Shuang

    2011-01-01

    Classical density functional theory is used to study the associating Lennard—Jones fluids in contact with spherical hard wall of different curvature radii. The interfacial properties including contact density and fluid-solid interfacial tension are investigated. The influences of associating energy, curvature of hard wall and the bulk density of fluids on these properties are analyzed in detail. The results may provide helpful clues to understand the interfacial properties of other complex fluids. (condensed matter: structure, mechanical and thermal properties)

  4. Flow of two stratified fluids in an open channel with addition of fluids along the channel length

    International Nuclear Information System (INIS)

    Gardner, G.C.

    1980-01-01

    It is shown that two stably stratified fluids flowing in an open channel have two critical flow conditions. The one at higher flowrates is equivalent to the choked flow condition of a single fluid over a broad-crested weir, when the Froude number is unity. The lower critical condition imposes restrictions, which define the system if fluids are added progressively along the channel length and the flowrates increase from low to high values. However, if the flowrate does not become sufficiently large to pass through the lower critical condition, this condition will then define a form of choking, which again determines the system. It is shown that an important special case, with the proportional flowrates of the two fluids kept constant, has an analytical solution in which the relative depths of the fluids is a constant along the channel. Other systems must be solved numerically. (orig.)

  5. Study of grid independence of finite element method on MHD free convective casson fluid flow with slip effect

    Science.gov (United States)

    Raju, R. Srinivasa; Ramesh, K.

    2018-05-01

    The purpose of this work is to study the grid independence of finite element method on MHD Casson fluid flow past a vertically inclined plate filled in a porous medium in presence of chemical reaction, heat absorption, an external magnetic field and slip effect has been investigated. For this study of grid independence, a mathematical model is developed and analyzed by using appropriate mathematical technique, called finite element method. Grid study discussed with the help of numerical values of velocity, temperature and concentration profiles in tabular form. avourable comparisons with previously published work on various special cases of the problem are obtained.

  6. The role of concavo-convex walls of a nanopore on the density profile, adsorption, solvation force, and capillary condensation of confined fluids: A DFT study

    International Nuclear Information System (INIS)

    Helmi, Abbas; Keshavarzi, Ezat

    2014-01-01

    Highlights: • The effect of concavo-convex walls of nanopores on the density profile was studied. • For HS fluids the contact density at concave wall is greater than for convex wall. • For Yukawa fluid the contact density at concave wall can be less than convex wall. • Capillary condensation was observed for Yukawa fluids in the homocentric pores. - Abstract: We investigate the effects of concavo-convex walls of a nanopore on the structure and certain thermodynamic properties of confined fluids. Adsorption, solvation force, and capillary condensation in a nanopore formed between two homocentric spheres will be determined using the MFMT. For hard sphere fluids, contact density is greater at the concave wall than it is at the convex wall. In Yukawa fluids, for the thermodynamic state in which the energy effect is the dominant factor, contact density at a concave wall is less than that at a convex wall; this will be reversed for the thermodynamic state in which the entropy effect is the dominant factor. It is possible to find thermodynamic states in which contact densities at concave and convex walls become identical. The adsorption and solvation force of hard sphere fluid show an oscillatory behavior versus H. Capillary condensation is in certain cases observed for Yukawa fluids

  7. Geological setting of silica in Dehnow-Abid region (Eshghabad northeast using fluid inclusions studies

    Directory of Open Access Journals (Sweden)

    Omid Yazdanpanah

    2017-02-01

    Full Text Available Introduction Dehnow-Abid area is a part of the geological map of Eshghabad with scale 1:100000 (Aghanabati, 1994 that is located about 20 kilometers northeast of Eshghabad and in the coordinates of 57° 6´ 0" to 57° 10´ 0" eastern longitude and 34° 28´ 0" to 34 21´ 0" northern latitude. The Dehnow-Abid area is located in Tabas block and east of central Iran structural zone. The small continent east central Iran (Takin, 1972 includes blocks: Loot, Tabas and Yazd that constitute Iran's eastern part (Davoudzadeh and Schmidt, 1982. In geology, we can acquire more information about temperature forming minerals and rocks, pressure, density of the fluid and the chemical composition of the ore bearing fluids by fluid inclusions studies. Properties as well as their role in our understanding of the sources and evolution of ore bearing hydrothermal fluids and genesis of mineral deposits are very important (Rodder, 1979. In this study, we tried to use both field and laboratory studies, including petrography and thermometry studies of fluid inclusions, environment formation of quartz in the specified Dehno-Abid. Materials and methods At first, in order to identify the area, the 1:100000 map of Eshghabad was used. Then, for a complete cognition of mentioned area, after a few field visits and sampling of outcrops of quartz, we prepared 16 double polishing sections from some crystalline and milky quartz. Then, 10 thin sections of sandstones of that area were prepared for identification the host rock. Microscopic examinations on fluid inclusions were done by a LEICA DMLSP polarizing light microscope. Fluid inclusion micro-thermometry studies were done by using a Linkam THM S600 heating and freezing stage and with a TMS94 controller. Also, a cooling LNP which is mounted on an Olympus BX-41 microscope in Laboratory Fluid inclusion of Earth Sciences, Damghan University was used. Discussion and results Lithology of the Dehnow-Abid area included dark shale

  8. Study of the motion of a vertically falling sphere in a viscous fluid

    International Nuclear Information System (INIS)

    Soares, A A; Caramelo, L; Andrade, M A P M

    2012-01-01

    This paper aims at contributing to a better understanding of the motion of spherical particles in viscous fluids. The classical problem of spheres falling through viscous fluids for small Reynolds numbers was solved taking into account the effects of added mass. The analytical solution for the motion of a falling sphere, from the beginning to the end of the fall, was combined with an iterative numerical method to determine the fluid viscosity coefficient, diameter of the sphere and terminal velocity. The proposed solution was validated with experimental literature data. The study presented may also help understanding the fluid-particle interactions from both theoretical and educational standpoints. (paper)

  9. Heat and mass transfer in magnetohydrodynamic Casson fluid over an exponentially permeable stretching surface

    Directory of Open Access Journals (Sweden)

    C.S.K. Raju

    2016-03-01

    Full Text Available In this study we analyzed the flow, heat and mass transfer behavior of Casson fluid past an exponentially permeable stretching surface in presence of thermal radiation, magneticfield, viscous dissipation, heat source and chemical reaction. We presented dual solutions by comparing the results of the Casson fluid with the Newtonian fluid. The governing partial nonlinear differential equations of the flow, heat and mass transfer are transformed into ordinary differential equations by using similarity transformation and solved numerically by using Matlab bvp4c package. The effects of various non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented graphically. Also, the friction factor, Nusselt and Sherwood numbers are analyzed and presented in tabular form for both Casson and Newtonian fluids separately. Under some special conditions the results of the present study have an excellent agreement with existing studies for both Casson and Newtonian fluid cases.

  10. Simulation of Sound Waves Using the Lattice Boltzmann Method for Fluid Flow: Benchmark Cases for Outdoor Sound Propagation.

    Science.gov (United States)

    Salomons, Erik M; Lohman, Walter J A; Zhou, Han

    2016-01-01

    Propagation of sound waves in air can be considered as a special case of fluid dynamics. Consequently, the lattice Boltzmann method (LBM) for fluid flow can be used for simulating sound propagation. In this article application of the LBM to sound propagation is illustrated for various cases: free-field propagation, propagation over porous and non-porous ground, propagation over a noise barrier, and propagation in an atmosphere with wind. LBM results are compared with solutions of the equations of acoustics. It is found that the LBM works well for sound waves, but dissipation of sound waves with the LBM is generally much larger than real dissipation of sound waves in air. To circumvent this problem it is proposed here to use the LBM for assessing the excess sound level, i.e. the difference between the sound level and the free-field sound level. The effect of dissipation on the excess sound level is much smaller than the effect on the sound level, so the LBM can be used to estimate the excess sound level for a non-dissipative atmosphere, which is a useful quantity in atmospheric acoustics. To reduce dissipation in an LBM simulation two approaches are considered: i) reduction of the kinematic viscosity and ii) reduction of the lattice spacing.

  11. Differential diagnosis of perirenal cyctic or non-cyctic fluid collections

    International Nuclear Information System (INIS)

    Stoker, J.; Lameris, J.S.

    1989-01-01

    A perirenal fluid collection, which is fluid located between the renal capcule and renal fasciae, is not a frequent diagnostic finding. When seen, either cystic, pseuod-cystic, several diagnostic possibilities must be kept in mind. The differential diagnosis of perirenal fluid, except for adrenal fluid, and the perirenal anatomy are described on the basis of three illustrative cases. Emphasis is on the radiological aspects. (Author). 15 refs.; 7 figs.; 1 tab

  12. Axial annular flow of power-law fluids - applicability of the limiting cases

    Czech Academy of Sciences Publication Activity Database

    Filip, Petr; David, Jiří

    2007-01-01

    Roč. 52, č. 4 (2007), s. 365-371 ISSN 0001-7043 R&D Projects: GA ČR GA103/06/1033 Institutional research plan: CEZ:AV0Z20600510 Keywords : Concentric annuli * Poiseuile flow * annular flow * power- law fluids * flow rate * pressure drop Subject RIV: BK - Fluid Dynamics

  13. The transverse mobility of yield-stress fluids in fibrous media

    Science.gov (United States)

    Shahsavari, Setareh; McKinley, Gareth H.

    2015-11-01

    The pressure-drop/flow-rate relationship for fluids that exhibit a yield stress and a shear dependent viscosity flowing through fibrous media is studied numerically. The Cauchy momentum equation along with the Bingham or Herschel-Bulkley constitutive equations are solved for flow transverse to a periodic array of fibers and systematic parametric studies are used to understand the individual roles of geometrical characteristics and fluid rheological properties. We develop a scaling model to predict the fluid mobility as a function of the medium porosity and the Bingham number. In addition, using this scaling model we estimate the width of the unyielded region between two adjacent fibers. Numerical computations are combined with the scaling model to obtain a criterion for the critical pressure gradient required to drive flow. Variations in the size of the yielded zones, the velocity profiles and the resulting stress fields are investigated for the limiting cases of (i) densely packed fiber arrays and (ii) very sparsely distributed fibers, and the hydrodynamic transition between these configurations is investigated. While this work focuses on the flow of inelastic fluids, the methodology can be extended to consider more complex rheology such as flow of elasto-visco-plastic fluids.

  14. Diagnostic imaging of small amounts of pleural fluid: pleural effusion vs. physiologic pleural fluid.

    Science.gov (United States)

    Kocijancic, Igor

    2007-12-01

    The aim of this article is to present an overview of our 10 years clinical research work and early clinical experience with small pleural effusions. Small amounts of pleural fluid are severely difficult to identify with imaging methods (chest x-rays and ultrasound). Nevertheless, it may be an important finding, sometimes leading to a definitive diagnosis of pleural carcinomatosis, infection or other pathologic condition. Chest x-rays were used for many years for the diagnosis of small pleural effusions. Lateral decubitus chest radiographs represented a gold standard for imaging of small amounts of plural fluid for more than 80 years. In the last two decades, ultrasonography of pleural space became a leading real-time method for demonstrating small pleural effusions. Furthermore, the advent of sonographic technology actually enables detection of physiologic pleural fluid in some otherwise healthy individuals. In conclusion, new definitions of the key terms in the field of diagnostic imaging of small amounts of pleural fluid seem to be justified. We suggest that the term pleural fluid should determine physiologic pleural space condition while the term pleural effusion should only be used in the cases of pleural involvement or pleural illness.

  15. Steam generator transient studies using a simplified two-fluid computer code

    International Nuclear Information System (INIS)

    Munshi, P.; Bhatnagar, R.; Ram, K.S.

    1985-01-01

    A simplified two-fluid computer code has been used to simulate reactor-side (or primary-side) transients in a PWR steam generator. The disturbances are modelled as ramp inputs for pressure, internal energy and mass flow-rate for the primary fluid. The CPU time for a transient duration of 4 s is approx. 10 min on a DEC-1090 computer system. The results are thermodynamically consistent and encouraging for further studies. (author)

  16. Fluid intake in Spanish children and adolescents: a cross-sectional study

    OpenAIRE

    Fenández-Alvira, Juan Miguel; Iglesia, Iris; Ferreira-Pego, Cíntia; Babio, Nancy; Salas-Salvadó, Jordi; Moreno, Luis A.

    2014-01-01

    Introduction: Some studies demonstrated that dehydration process is prevalent among young populations and subsequently, a cause of concern. However, the evaluation of the fluid consumption pattern of children and adolescent populations has not been widely assessed. Objective: To evaluate the total fluid intake from different types of beverages in Spanish children and adolescents. Methods: A total of 238 children and adolescents aged 3-17 years were randomly recruited from all Spanish regions....

  17. Micropolar Fluids Using B-spline Divergence Conforming Spaces

    KAUST Repository

    Sarmiento, Adel

    2014-06-06

    We discretized the two-dimensional linear momentum, microrotation, energy and mass conservation equations from micropolar fluids theory, with the finite element method, creating divergence conforming spaces based on B-spline basis functions to obtain pointwise divergence free solutions [8]. Weak boundary conditions were imposed using Nitsche\\'s method for tangential conditions, while normal conditions were imposed strongly. Once the exact mass conservation was provided by the divergence free formulation, we focused on evaluating the differences between micropolar fluids and conventional fluids, to show the advantages of using the micropolar fluid model to capture the features of complex fluids. A square and an arc heat driven cavities were solved as test cases. A variation of the parameters of the model, along with the variation of Rayleigh number were performed for a better understanding of the system. The divergence free formulation was used to guarantee an accurate solution of the flow. This formulation was implemented using the framework PetIGA as a basis, using its parallel stuctures to achieve high scalability. The results of the square heat driven cavity test case are in good agreement with those reported earlier.

  18. Experimental study on the fluid stratification mechanism in the density lock

    International Nuclear Information System (INIS)

    Gu Haifeng; Yan Changqi; Sun Licheng

    2009-01-01

    Visualized experiments were conducted on the forming process of stratification between hot and cold fluids in three tubes with different diameters. The results show that the working fluids were divided into three layers from top to bottom: convective, interfacial, and constant temperature layers. The working fluid in the convective layer always retains the property of a high rate of temperature increase. The rate of temperature increase in the interfacial layer gradually decreased from top to bottom and was less than that in the convective layer. The working fluid temperature in the constant-temperature layer remained stable. Based on the experimental study, we built a simplified theoretical model and analyzed the stratification mechanism. The results indicate the following stratification mechanism: because of the existence of the transition points in the heat transfer modes, the differences in the rates of temperature increase appear. These differences result in the appearance of fluid stratification. In addition, research on the process of stratification under different conditions tells us that the structure of the density lock influences the position of the transition point. The density lock with a structure of variable cross-sectional grids can effectively control the position of the transition points of the heat transfer modes. (author)

  19. The study of crosslinked fluid leakoff in hydraulic fracturing physical simulations

    Energy Technology Data Exchange (ETDEWEB)

    Grothe, Vinicius Perrud; Ribeiro, Paulo Roberto [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo; Sousa, Jose Luiz Antunes de Oliveira e [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia. Dept. de Estruturas; Fernandes, Paulo Dore [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2000-07-01

    The fluid loss plays an important role in the design and execution of hydraulic fracturing treatments. The main objectives of this work were: the study of the fluid loss associated with the propagation of hydraulic fractures generated at laboratory; and the comparison of two distinct methods for estimating leakoff coefficients - Nolte analysis and the filtrate volume vs. square root of time plot. Synthetic rock samples were used as well as crosslinked hydroxypropyl guar (HPG) fluids in different polymer concentrations. The physical simulations comprised the confinement of (0.1 x 0.1 x 0.1) m{sup 3} rock samples in a load cell for the application of an in situ stress field. Different flow rates were employed in order to investigate shear effects on the overall leakoff coefficient. Horizontal radial fractures were hydraulically induced with approximate diameters, what was accomplished by controlling the injection time. Leakoff coefficients determined by means of the pressure decline analysis were compared to coefficients obtained from static filtration tests, considering similar experimental conditions. The research results indicated that the physical simulation of hydraulic fracturing may be regarded as an useful tool for evaluating the effectiveness of fracturing fluids and that it can supply reliable estimates of fluid loss coefficients. (author)

  20. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation.

    Science.gov (United States)

    Priyadharshini, S; Ponalagusamy, R

    2015-01-01

    An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R = 0 to r/R = 1 and it follows a concave pattern when we move from r/R = 0 to r/R = -1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  1. Fluid-Thermal-Structural Coupled Analysis of a Radial Inflow Micro Gas Turbine Using Computational Fluid Dynamics and Computational Solid Mechanics

    Directory of Open Access Journals (Sweden)

    Yonghui Xie

    2014-01-01

    Full Text Available A three-dimensional fluid-thermal-structural coupled analysis for a radial inflow micro gas turbine is conducted. First, a fluid-thermal coupled analysis of the flow and temperature fields of the nozzle passage and the blade passage is performed by using computational fluid dynamics (CFD. The flow and heat transfer characteristics of different sections are analyzed in detail. The thermal load and the aerodynamic load are then obtained from the temperature field and the pressure distribution. The stress distributions of the blade are finally studied by using computational solid mechanics (CSM considering three cases of loads: thermal load, aerodynamics load combined with centrifugal load, and all the three types of loads. The detailed parameters of the flow, temperature, and the stress are obtained and analyzed. The numerical results obtained provide a useful knowledge base for further exploration of radial gas turbine design.

  2. Attractors of equations of non-Newtonian fluid dynamics

    International Nuclear Information System (INIS)

    Zvyagin, V G; Kondrat'ev, S K

    2014-01-01

    This survey describes a version of the trajectory-attractor method, which is applied to study the limit asymptotic behaviour of solutions of equations of non-Newtonian fluid dynamics. The trajectory-attractor method emerged in papers of the Russian mathematicians Vishik and Chepyzhov and the American mathematician Sell under the condition that the corresponding trajectory spaces be invariant under the translation semigroup. The need for such an approach was caused by the fact that for many equations of mathematical physics for which the Cauchy initial-value problem has a global (weak) solution with respect to the time, the uniqueness of such a solution has either not been established or does not hold. In particular, this is the case for equations of fluid dynamics. At the same time, trajectory spaces invariant under the translation semigroup could not be constructed for many equations of non-Newtonian fluid dynamics. In this connection, a different approach to the construction of trajectory attractors for dissipative systems was proposed in papers of Zvyagin and Vorotnikov without using invariance of trajectory spaces under the translation semigroup and is based on the topological lemma of Shura-Bura. This paper presents examples of equations of non-Newtonian fluid dynamics (the Jeffreys system describing movement of the Earth's crust, the model of motion of weak aqueous solutions of polymers, a system with memory) for which the aforementioned construction is used to prove the existence of attractors in both the autonomous and the non-autonomous cases. At the beginning of the paper there is also a brief exposition of the results of Ladyzhenskaya on the existence of attractors of the two-dimensional Navier-Stokes system and the result of Vishik and Chepyzhov for the case of attractors of the three-dimensional Navier-Stokes system. Bibliography: 34 titles

  3. Numerical and experimental study of expiratory flow in the case of major upper airway obstructions with fluid structure interaction

    Science.gov (United States)

    Chouly, F.; van Hirtum, A.; Lagrée, P.-Y.; Pelorson, X.; Payan, Y.

    2008-02-01

    This study deals with the numerical prediction and experimental description of the flow-induced deformation in a rapidly convergent divergent geometry which stands for a simplified tongue, in interaction with an expiratory airflow. An original in vitro experimental model is proposed, which allows measurement of the deformation of the artificial tongue, in condition of major initial airway obstruction. The experimental model accounts for asymmetries in geometry and tissue properties which are two major physiological upper airway characteristics. The numerical method for prediction of the fluid structure interaction is described. The theory of linear elasticity in small deformations has been chosen to compute the mechanical behaviour of the tongue. The main features of the flow are taken into account using a boundary layer theory. The overall numerical method entails finite element solving of the solid problem and finite differences solving of the fluid problem. First, the numerical method predicts the deformation of the tongue with an overall error of the order of 20%, which can be seen as a preliminary successful validation of the theory and simulations. Moreover, expiratory flow limitation is predicted in this configuration. As a result, both the physical and numerical models could be useful to understand this phenomenon reported in heavy snorers and apneic patients during sleep.

  4. In situ experimental study of subduction zone fluids using diamond anvil cells

    Science.gov (United States)

    Bureau, H.; Foy, E.; Somogyi, A.; Munsch, P.; Simon, G.; Kubsky, S.

    2008-12-01

    Experiments carried out in diamond anvil cells combined with in situ synchrotron light source measurements represent the only one issue to observe and study fluid equilibria in real time, at the pressure and temperature conditions of the subduction zones. We will present new results recently obtained at the DIFFABS beam line (SOLEIL Synchrotron) aiming at studying equilibria between silica-rich hydrous melts and aqueous fluids in the presence of U, Th, Pb, Ba and Br. We used synchrotron X-Ray fluorescence analysis performed in situ in Bassett-modified hydrothermal diamond anvil cells in order to monitor the chemical transfers of the studied elements between the phases in equilibrium at different pressures (up to 1.6 GPa) and temperatures (up to 900°C). We have calculated the partition coefficients for each studied element (i): Difluid/melt = Cifluid/Cimelt. Results show that U and Th exhibit more affinities for the silica-rich hydrous fluids in the presence or absence of Br, considered here such as an analogue for Cl, (i.e. 0.4 > 10 after decompression) this coefficient decreases with pressure suggesting that Br would not be immediately washed out from the subducted plate during dehydration but may be recycled deeper in the mantle. These new data combined with previous ones obtained for Pb, Ba (Bureau et al., 2007, HPR vol 27, p. 235) and Rb, Sr, Zr (Bureau et al., 2004, Eos Trans. AGU, 85(47), V11C-05), allow us to propose a general outline of the fluid phase transfers through the subduction factory: (1) at shallow level: their nature and composition, the impact of the presence of halogens and the fertilizing role of such fluids in the mantle wedge, where the generation of arc magmas takes place (2) deeper in the mantle: where hydrous silica-rich supercritical fluids may also favour a deep recycling of a fraction of volatiles and trace elements present in the subducted oceanic crust.

  5. Intraabdominal serous fluid collections after appendectomy: a normal sonographic finding.

    Science.gov (United States)

    Aveline, B; Guimaraes, R; Bely, N; Salles, J P; Cugnenc, P H; Frija, G

    1993-07-01

    The significance of sonographic findings 1 week or less after appendectomy is difficult to evaluate without knowing the inconsequential abnormalities that may occur in these patients. Accordingly, we performed postoperative sonography on patients who had a normal course after appendectomy to determine the findings that can be considered normal within 1 week after surgery. Forty-four patients who had an appendectomy for acute appendicitis and who had normal findings at clinical follow-up 5 days and 6 months later were included in the study. In all patients, sonograms were obtained on the fifth postoperative day and interpreted by a radiologist who did not know the surgical findings. Ten fluid collections (23%) were found in the pericecal area, ranging in size from 10 x 10 mm to 40 x 20 mm. The collections were hypoechoic or anechoic, crescent-shaped, and immobile. Fluid collections were more common in cases of suppurative appendixes (6/20, 30%) than in cases of inflamed appendixes (4/19, 21%) and in retrocecal appendixes (3/9, 33%) than in normally located appendixes (7/34, 21%). However, the differences were not statistically significant (p > .05). Inconsequential fluid collections are detected with considerable frequency on postoperative sonograms 5 days after an appendectomy. Consequently, not every fluid collection should be considered an abscess.

  6. A prospective study of endoscopic ultrasonography features, cyst fluid carcinoembryonic antigen, and fluid cytology for the differentiation of small pancreatic cystic neoplasms.

    Science.gov (United States)

    Wang, Ying; Chai, Ningli; Feng, Jia; Linghu, Enqiang

    2017-08-24

    With improvements in imaging technologies, pancreatic cystic lesions (PCLs) have been increasingly identified in recent years. However, the imaging modalities used to differentiate the categories of pancreatic cysts remain limited, which may cause confusion when planning treatment. Due to progress in endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) technology, auxiliary diagnosis by the detection of cystic fluid has become a recent trend. From March 2015 to April 2016, 120 patients with PCLs were enrolled in this study. According to the results of EUS, cyst fluid carcinoembryonic antigen (CEA) analysis, and cystic fluid cytology, the patients were divided into two groups: a nonmucinous and a mucinous group. Of those, 61 patients who had undergone surgical resection were included in the analysis. The clinical features, biochemical and tumor markers of cyst fluid as well as the cytological test results of the patients were compared with histopathology results. A cyst size of 4.0 cm was used as the boundary value; a cyst ≤4.0 cm was defined as a small PCL. 87 (72.5%) lesions were ≤4.0 cm, and 33 (27.5%) lesions were >4.0 cm. Regarding the analysis of CEA and carbohydrate antigens 19-9 (CA19-9), significant differences were found between the nonmucinous and mucinous groups (P < 0.05) according to nonparametric independent samples tests. The EUS, cystic fluid CEA, and cystic fluid cytology results were compared with the tissue pathology findings using McNemar's test (P < 0.05) and showed a sensitivity of 90% and a specificity of 84%. A diagnostic combination of EUS, cyst fluid CEA, and cystic fluid cytology could be used to differentiate small pancreatic cystic neoplasms. Cystic fluid cytology analysis is helpful for planning treatment for pancreatic cystic tumors that pose a surgical risk.

  7. Effectiveness of a fluid chart in outpatient management of suspected dengue fever: A pilot study.

    Science.gov (United States)

    Nasir, Nazrila Hairin; Mohamad, Mohazmi; Lum, Lucy Chai See; Ng, Chirk Jenn

    2017-01-01

    Dengue infection is the fastest spreading mosquito-borne viral disease in the world. One of the complications of dengue is dehydration which, if not carefully monitored and treated, may lead to shock, particularly in those with dengue haemorrhagic fever. WHO has recommended oral fluid intake of five glasses or more for adults who are suspected to have dengue fever. However, there have been no published studies looking at self-care intervention measures to improve oral fluid intake among patients suspected of dengue fever. To assess the feasibility and effectiveness of using a fluid chart to improve oral fluid intake in patients with suspected dengue fever in a primary care setting. This feasibility study used a randomized controlled study design. The data was collected over two months at a primary care clinic in a teaching hospital. The inclusion criteria were: age > 12 years, patients who were suspected to have dengue fever based on the assessment by the primary healthcare clinician, fever for > three days, and thrombocytopenia (platelets dengue home care card. The intervention group received the fluid chart and a cup (200ml). Baseline clinical and laboratory data, 24-hour fluid recall (control group), and fluid chart were collected. The main outcomes were: hospitalization rates, intravenous fluid requirement and total oral fluid intake. Among the 138 participants who were included in the final analysis, there were fewer hospital admissions in the intervention group (n = 7, 10.0%) than the control group (n = 12, 17.6%) (p = 0.192). Similarly, fewer patients (n = 9, 12.9%) in the intervention group required intravenous fluid compared to the control group (n = 15, 22.1%), (p = 0.154). There was an increase in the amount of daily oral fluid intake in the intervention group (about 3,000 ml) compared to the control group (about 2,500 ml, p = 0.521). However, these differences did not reach statistical significance. This is a feasible and acceptable study to perform in

  8. Impacts modeling using the SPH particulate method. Case study

    International Nuclear Information System (INIS)

    Debord, R.

    1999-01-01

    The aim of this study is the modeling of the impact of melted metal on the reactor vessel head in the case of a core-meltdown accident. Modeling using the classical finite-element method alone is not sufficient but requires a coupling with particulate methods in order to take into account the behaviour of the corium. After a general introduction about particulate methods, the Nabor and SPH (smoothed particle hydrodynamics) methods are described. Then, the theoretical and numerical reliability of the SPH method is determined using simple cases. In particular, the number of neighbours significantly influences the preciseness of calculations. Also, the mesh of the structure must be adapted to the mesh of the fluid in order to reduce the edge effects. Finally, this study has shown that the values of artificial velocity coefficients used in the simulation of the BERDA test performed by the FZK Karlsruhe (Germany) are not correct. The domain of use of these coefficients was precised during a low speed impact. (J.S.)

  9. Hydromagnetic stability of rotating stratified compressible fluid flows

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasan, V; Kandaswamy, P [Dept. of Mathematics, Bharathiar University, Coimbatore, Tamil Nadu, India; Debnath, L [Dept. of Mathematics, University of Central Florida, Orlando, USA

    1984-09-01

    The hydromagnetic stability of a radially stratified compressible fluid rotating between two coaxial cylinders is investigated. The stability with respect to axisymmetric disturbances is examined. The fluid system is found to be thoroughly stable to axisymmetric disturbances provided the fluid rotates very rapidly. The system is shown to be unstable to non-axisymmetric disturbances, and the slow amplifying hydromagnetic wave modes propagate against the basic rotation. The lower and upper bounds of the azimuthal phase speeds of the amplifying waves are determined. A quadrant theorem on the slow waves characteristic of a rapidly rotating fluid is derived. Special attention is given to the effects of compressibility of the fluid. Some results concerning the stability of an incompressible fluid system are obtained as special cases of the present analysis.

  10. Contamination control in HVAC systems for aseptic processing area. Part I: Case study of the airflow velocity in a unidirectional airflow workstation with computational fluid dynamics.

    Science.gov (United States)

    Ogawa, M

    2000-01-01

    A unidirectional airflow workstation for processing a sterile pharmaceutical product is required to be "Grade A," according to EU-GMP and WHO-GMP. These regulations have employed the wording of "laminar airflow" for unidirectional airflow, with an unclear definition given. This seems to have allowed many reports to describe discussion of airflow velocity only. The guidance values as to the velocity are expressed in various words of 90 ft/min, 0.45 m/sec, 0.3 m/sec, +/- 20%, or "homogeneous air speed." It has been also little clarified how variation in airflow velocity gives influences on contamination control of a workstation working with varying key characteristics, such as ceiling height, internal heat load, internal particle generation, etc. The present author has revealed following points from a case study using Computational Fluid Dynamics: the airflow characteristic in Grade A area shows no significant changes with varying the velocity of supplied airflow, and the particles generated from the operator will be exhausted outside Grade A area without contamination.

  11. Oral bacterial DNA findings in pericardial fluid

    Directory of Open Access Journals (Sweden)

    Anne-Mari Louhelainen

    2014-11-01

    Full Text Available Background: We recently reported that large amounts of oral bacterial DNA can be found in thrombus aspirates of myocardial infarction patients. Some case reports describe bacterial findings in pericardial fluid, mostly done with conventional culturing and a few with PCR; in purulent pericarditis, nevertheless, bacterial PCR has not been used as a diagnostic method before. Objective: To find out whether bacterial DNA can be measured in the pericardial fluid and if it correlates with pathologic–anatomic findings linked to cardiovascular diseases. Methods: Twenty-two pericardial aspirates were collected aseptically prior to forensic autopsy at Tampere University Hospital during 2009–2010. Of the autopsies, 10 (45.5% were free of coronary artery disease (CAD, 7 (31.8% had mild and 5 (22.7% had severe CAD. Bacterial DNA amounts were determined using real-time quantitative PCR with specific primers and probes for all bacterial strains associated with endodontic disease (Streptococcus mitis group, Streptococcus anginosus group, Staphylococcus aureus/Staphylococcus epidermidis, Prevotella intermedia, Parvimonas micra and periodontal disease (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Treponema denticola, Fusobacterium nucleatus, and Dialister pneumosintes. Results: Of 22 cases, 14 (63.6% were positive for endodontic and 8 (36.4% for periodontal-disease-associated bacteria. Only one case was positive for bacterial culturing. There was a statistically significant association between the relative amount of bacterial DNA in the pericardial fluid and the severity of CAD (p=0.035. Conclusions: Oral bacterial DNA was detectable in pericardial fluid and an association between the severity of CAD and the total amount of bacterial DNA in pericardial fluid was found, suggesting that this kind of measurement might be useful for clinical purposes.

  12. Hyponatremia and SIADH: A Case Study for Nursing Consideration.

    Science.gov (United States)

    Tasler, Teri; Bruce, Susan D

    2018-02-01

    The leading cause of hyponatremia in patients with cancer is syndrome of inappropriate antidiuretic hormone secretion (SIADH); this oncologic emergency requires immediate intervention. Left untreated, it can result in increased mortality and morbidity. A sodium level less than 135 meq/L is an electrolyte irregularity and defined as hyponatremia. It is extremely critical that oncology nurses are knowledgeable and able to evaluate and determine when patients are in fluid and electrolyte crisis. Nurses should be aware of the specific cancers and treatments that put patients at risk for developing hyponatremia. This article presents a case study for nursing consideration.

  13. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  14. Gravitational equilibrium of a multi-body fluid system

    International Nuclear Information System (INIS)

    Eriguchi, Yoshiharu; Hachisu, Izumi.

    1983-01-01

    We have computed gravitational equilibrium sequences for systems consisting of N incompressible fluid bodies (N = 3, 4, 5). The component fluids are assumed congruent. The system seems to become a lobe-like shape for N = 3 case and a ring-like shape for N>=4 cases according as the fluid bodies come nearer to each other. For every sequence there is a critical equilibrium whose dimensionless angular momentum has the minimum value of the sequence. As the final outcome is nearly in equilibrium in the computation of a collapsing gas cloud, we can apply the present results to the interpretation of these dynamical calculations. For instance, the gas cloud can never fissure into any N-body equilibrium when its dimensionless angular momentum is below the critical value of the N-body sequence. (author)

  15. Petrography and fluid inclusions study in Marbin porphyry Molybdenum (Sn) index (northeast of Isfahan)

    International Nuclear Information System (INIS)

    Mirzaei, M.; Bagheri, H.; Ayati, F.

    2016-01-01

    Marbin Tin and Molybdenum index is located in north of Zefreh Village the Isfahan Province and Uromieh-Dokhtar magmatic zone. The main rock units in this area are Eocene subvolcanic and volcanic rocks with rhyolite to dacite composition. Based on petrography studies the main minerals are plagioclase, quartz, sanidine and biotite and secondary minerals are chlorite, calcite, epidote and sericite. The main hydrothermal alterations are including sericitic, propylitic, intermediate argillic and silisification. Average grade of tin, molybdenum, copper and gold is about 4850, 157, 330 ppm and 82 ppb, respectively. Microthermometric studies on silica veins and veinlet indicate five different types of fluid inclusion, 1-three-phase type (L+V+S→L), 2- three-phase type (L+V+S→V), 3- two-phase type (L+V→L), 4- two-phase type (V+L→V), 5- vapor rich single phase type (V). Fluid inclusion studies in mineralized veins in phyllic and propylitic zones, show the wide range of homogenization temperature from 248 to 600 ºC and salinity from 28 to 65 wt% NaCl equivalent. The temperature, salinity and density of fluids decrease from phyllic to propylitic alteration zone. The wide range of homogenization temperatures for the studied fluid inclusions in index show dilution with surface water and fluid boiling, as the most important factor in ore deposition. According to field, mineralogical, geochemical and fluid inclusion studies Marbin index has been considered as a porphyry deposit type which show the most similarity with Mo porphyry systems in world wide.

  16. Re-injection feasibility study of fracturing flow-back fluid in shale gas mining

    Science.gov (United States)

    Kang, Dingyu; Xue, Chen; Chen, Xinjian; Du, Jiajia; Shi, Shengwei; Qu, Chengtun; Yu, Tao

    2018-02-01

    Fracturing flow-back fluid in shale gas mining is usually treated by re-injecting into formation. After treatment, the fracturing flow-back fluid is injected back into the formation. In order to ensure that it will not cause too much damage to the bottom layer, feasibility evaluations of re-injection of two kinds of fracturing fluid with different salinity were researched. The experimental research of the compatibility of mixed water samples based on the static simulation method was conducted. Through the analysis of ion concentration, the amount of scale buildup and clay swelling rate, the feasibility of re-injection of different fracturing fluid were studied. The result shows that the swelling of the clay expansion rate of treated fracturing fluid is lower than the mixed water of treated fracturing fluid and the distilled water, indicating that in terms of clay expansion rate, the treated fracturing flow-back fluid is better than that of water injection after re-injection. In the compatibility test, the maximum amount of fouling in the Yangzhou oilfield is 12mg/L, and the maximum value of calcium loss rate is 1.47%, indicating that the compatibility is good. For the fracturing fluid with high salinity in the Yanchang oilfield, the maximum amount of scaling is 72mg/L, and the maximum calcium loss rate is 3.50%, indicating that the compatibility is better.

  17. Experimental study and CFD simulation of rotational eccentric cylinder in a magnetorheological fluid

    International Nuclear Information System (INIS)

    Omidbeygi, F.; Hashemabadi, S.H.

    2012-01-01

    In this study, a magnetorheological (MR) fluid is prepared using carbonyl iron filings and low viscosity lubricating oil. The effects of magnetic field and weight percentage of particles on the viscosity of the MR fluid have been measured using a rotational viscometer. The yield stress under an applied magnetic field was also obtained experimentally. In the absence of an applied magnetic field, the MR fluid behaves as a Newtonian fluid. When the magnetic field is applied, the MR fluid behaves like Bingham plastics with a magnetic field dependent yield stress. Afterward, the results compared with those of CFD simulation of two eccentric cylinders in the MR fluid. Results show that the influences of MR effects, caused by the applied magnetic field, on the model characteristics are significant and not negligible. The viscosity is enhanced by increasing of the magnetic field, eccentricity ratio and weight percentage of suspensions. The MR effects and increasing of weight percentage and eccentricity ratio also provide an enhancement in the yield stresses and required total torque for rotation of inner cylinder. Also the simulation results indicate a good representation of the experiment by the model. - Highlights: ► Preparation of a magnetorheological fluid with carbonyl iron particles in lubricating oil. ► Rheological measurement for influence of solid content and magnetic field intensity. ► Simulation of eccentric rotating cylinder in prepared MR fluid with CFD techniques.

  18. Active chiral fluids.

    Science.gov (United States)

    Fürthauer, S; Strempel, M; Grill, S W; Jülicher, F

    2012-09-01

    Active processes in biological systems often exhibit chiral asymmetries. Examples are the chirality of cytoskeletal filaments which interact with motor proteins, the chirality of the beat of cilia and flagella as well as the helical trajectories of many biological microswimmers. Here, we derive constitutive material equations for active fluids which account for the effects of active chiral processes. We identify active contributions to the antisymmetric part of the stress as well as active angular momentum fluxes. We discuss four types of elementary chiral motors and their effects on a surrounding fluid. We show that large-scale chiral flows can result from the collective behavior of such motors even in cases where isolated motors do not create a hydrodynamic far field.

  19. An experimental study on the normal stress of magnetorheological fluids

    International Nuclear Information System (INIS)

    Jiang, Jile; Tian, Yu; Ren, Dongxue; Meng, Yonggang

    2011-01-01

    The dependence of the normal stress on the shear rate and magnetic field strength in the shear flow of magnetorheological (MR) fluids has been studied experimentally. An obvious normal stress could be observed when the applied magnetic field was higher than a critical value. The normal stress increases considerably with increase of the shear rate and magnetic field, and decreases suddenly and significantly upon the onset of shear thickening in MR fluids. The ratio of shear stress to normal stress, an analogue of the friction coefficient, increases with increase of the shear rate, but decreases with increase of the applied magnetic field. Along with the shear stress, the normal stress in MR fluids could provide a more comprehensive understanding of the MR effect, and the evolution of the particle structure in shear flow, and may have important implications for preparing high performance magnetostrictive elastomers with high force output along the magnetic field direction

  20. A Parallel Two-fluid Code for Global Magnetic Reconnection Studies

    International Nuclear Information System (INIS)

    Breslau, J.A.; Jardin, S.C.

    2001-01-01

    This paper describes a new algorithm for the computation of two-dimensional resistive magnetohydrodynamic (MHD) and two-fluid studies of magnetic reconnection in plasmas. It has been implemented on several parallel platforms and shows good scalability up to 32 CPUs for reasonable problem sizes. A fixed, nonuniform rectangular mesh is used to resolve the different spatial scales in the reconnection problem. The resistive MHD version of the code uses an implicit/explicit hybrid method, while the two-fluid version uses an alternating-direction implicit (ADI) method. The technique has proven useful for comparing several different theories of collisional and collisionless reconnection

  1. Prospects of the use of nanofluids as working fluids for organic Rankine cycle power systems

    DEFF Research Database (Denmark)

    Mondejar, Maria E.; Andreasen, Jesper G.; Regidor, Maria

    2017-01-01

    The search of novel working fluids for organic Rankine cycle power systems is driven by the recent regulations imposing additional phase-out schedules for substances with adverse environmental characteristics. Recently, nanofluids (i.e. colloidal suspensions of nanoparticles in fluids) have been...... suggested as potential working fluids for organic Rankine cycle power systems due to their enhanced thermal properties, potentially giving advantages with respect to the design of the components and the cycle performance. Nevertheless, a number of challenges concerning the use of nanofluids must...... the prospects of using nanofluids as working fluids for organic Rankine cycle power systems. As a preliminary study, nanofluids consisting of a homogenous and stable mixture of different nanoparticles types and a selected organic fluid are simulated on a case study organic Rankine cycle unit for waste heat...

  2. On perfect fluids and black holes in static equilibrium

    International Nuclear Information System (INIS)

    Carrasco, Alberto; Mars, Marc; Simon, Walter

    2007-01-01

    Proofs of spherical symmetry of static black holes and of spherical symmetry of static perfect fluids normally require, a priori, 'black holes only' or 'fluid only'. In a recent paper Shiromizu, Yamada and Yoshino admit a priori (and exclude) coexistence of fluids and holes. This work assumes connectedness of the fluid region and the same assumptions on the equation of state as earlier papers on the 'fluid only' case, and requires in addition an upper bound for the fluid mass in terms of the black holes masses. We discuss this paper. As a new result we show that there cannot exist static fluid shells (i.e. fluid regions of the topology of an annulus) even if one a priori admits, inside and outside the shell, any arrangement of black holes or additional matter which satisfies the energy condition

  3. Fluid effects on the core seismic behavior of a liquid metal reactor

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Lee, Jae Han

    2004-01-01

    In this paper, a numerical application algorithm for applying the CFAM (Consistent Fluid Added Mass) matrix for a core seismic analysis is developed and applied to the 7-ducts core system to investigate the fluid effects on the dynamic characteristics and the seismic time history responses. To this end, three cases such as the in-air condition, the in-water condition without the fluid coupling terms, and the in-water condition with the fluid coupling terms are considered in this paper. From modal analysis, the core duct assemblies revealed strongly coupled out-of-phase vibration modes unlike the other cases with the fluid coupling terms considered. From the results of the seismic time history analysis, it was also verified that the fluid coupling terms in the CFAM matrix can significantly affect the impact responses and the seismic displacement responses of the ducts

  4. Triple Pancreatic Walled-off Fluid Collections Treated Simultaneously with Endoscopic Transmural Drainage.

    Science.gov (United States)

    Khalid, Sameen; Abbass, Aamer; Nellis, Eric; Shah, Shashin; Shah, Hiral

    2018-01-09

    Pancreatic pseudocysts and walled-off pancreatic necrosis arise as a complication of pancreatitis. Multiple fluid collections are seen in 5-20% of the patients who have walled-off peripancreatic fluid collections. There is a paucity of data regarding the role of endoscopic transmural drainage in the management of multiple pancreatic fluid collections. In this case report, we present the case of a 72-year-old male with three walled-off pancreatic fluid collections in the setting of acute necrotizing pancreatitis. The patient underwent simultaneous endoscopic ultrasound-assisted cyst gastrostomy and cyst duodenostomy and aggressive irrigation without index endoscopic necrosectomy of the three peripancreatic fluid collections. Significant improvement in the size of the fluid collections was seen on the computed tomography scan, as well as a remarkable immediate clinical improvement after 24 hours of the endoscopic intervention.

  5. Study of fluid inclusions in rodioactive mineralized pegmatites, dara area northern eastern desert, Egypt

    International Nuclear Information System (INIS)

    Ali, B.H.; Abdel Warith, A.

    2003-01-01

    Numerous pegmatite pockets of un zoned and zoned types are the most important rock types from the radioactive point of view. They occur at the marginal parts and higher topographic level of G.Dara younger granites. Zoned pegmatites are composed of extremely coarse-grained milky quartz core, intermediate zone and wall zone. The alteration zone is found at the contact between quartz core and intermediate zone. It is recorded the highest radioactive values due to their mineral composition, as a result of alteration processes associated with radioactive minerals. Only two alteration zones (P1 and P2) has been studied in this paper. The late magmatic alteration process (hematization, kaolinization, chloritization and fluortization) of the pegmatite resulted in the formation of chlorite, fluorite, clay minerals and carbonates (calcite) in the alteration zones as mineral assemblage. opaque minerals are found as pyrite, iron oxyhydroxide and garnet. Fluid inclusion studies by microthermometry were carried out on authigenic minerals (such as quartz and fluorite) in alteration zones (primary fluid inclusions). This study revealed that, at least two stages of the post-magmatic hydrothermal alteration are involved. The first stages of high temperature, low saline fluids are involved. The first stage is of high temperature, low saline fluids which characterized with hematization and/or chloritization resulted from fluid-rock interaction with late magmatic fluids that very probably mixed with external low salinity fluids along brittle structure. The second stage is of low temperature the main role in re high saline fluids characterized the fluoritized alteration due to consequent reaction with wall rocks and mixing with meteoric water. Mixing of low salinity meteoric water with hot a sending saline hydrothermal solution leads to ph change and continuous interaction with wall rock

  6. Fluid dynamics

    CERN Document Server

    Bernard, Peter S

    2015-01-01

    This book presents a focused, readable account of the principal physical and mathematical ideas at the heart of fluid dynamics. Graduate students in engineering, applied math, and physics who are taking their first graduate course in fluids will find this book invaluable in providing the background in physics and mathematics necessary to pursue advanced study. The book includes a detailed derivation of the Navier-Stokes and energy equations, followed by many examples of their use in studying the dynamics of fluid flows. Modern tensor analysis is used to simplify the mathematical derivations, thus allowing a clearer view of the physics. Peter Bernard also covers the motivation behind many fundamental concepts such as Bernoulli's equation and the stream function. Many exercises are designed with a view toward using MATLAB or its equivalent to simplify and extend the analysis of fluid motion including developing flow simulations based on techniques described in the book.

  7. Diagnosis of drowning using post-mortem computed tomography based on the volume and density of fluid accumulation in the maxillary and sphenoid sinuses.

    Science.gov (United States)

    Kawasumi, Yusuke; Kawabata, Tomoyoshi; Sugai, Yusuke; Usui, Akihito; Hosokai, Yoshiyuki; Sato, Miho; Saito, Haruo; Ishibashi, Tadashi; Hayashizaki, Yoshie; Funayama, Masato

    2013-10-01

    Recent studies have reported that drowning victims frequently have fluid accumulation in the paranasal sinuses, most notably the maxillary and sphenoid sinuses. However, in our previous study, many non-drowning victims also had fluid accumulation in the sinuses. Therefore, we evaluated the qualitative difference in fluid accumulation between drowning and non-drowning cases in the present study. Thirty-eight drowning and 73 non-drowning cases were investigated retrospectively. The fluid volume and density of each case were calculated using a DICOM workstation. The drowning cases were compared with the non-drowning cases using the Mann-Whitney U-test because the data showed non-normal distribution. The median fluid volume was 1.82 (range 0.02-11.7) ml in the drowning cases and 0.49 (0.03-8.7) ml in the non-drowning cases, and the median fluid density was 22 (-14 to 66) and 39 (-65 to 77) HU, respectively. Both volume and density differed significantly between the drowning and non-drowning cases (p=0.001, p=0.0007). Regarding cut-off levels in the ROC analysis, the points on the ROC curve closest (0, 1) were 1.03ml (sensitivity 68%, specificity 68%, PPV 53%, NPV 81%) and 27.5 HU (61%, 70%, 51%, 77%). The Youden indices were 1.03ml and 37.8 HU (84%, 51%, 47%, 86%). When the cut-off level was set at 1.03ml and 27.5HU, the sensitivity was 42%, specificity 45%, PPV 29% and NPV 60%. When the cut-off level was set at 1.03ml and 37.8HU, sensitivity was 58%, specificity 32%, PPV 31% and NPV 59%. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Stability of fault submitted to fluid injections

    Science.gov (United States)

    Brantut, N.; Passelegue, F. X.; Mitchell, T. M.

    2017-12-01

    Elevated pore pressure can lead to slip reactivation on pre-existing fractures and faults when the coulomb failure point is reached. From a static point of view, the reactivation of fault submitted to a background stress (τ0) is a function of the peak strength of the fault, i.e. the quasi-static effective friction coefficient (µeff). However, this theory is valid only when the entire fault is affected by fluid pressure, which is not the case in nature, and during human induced-seismicity. In this study, we present new results about the influence of the injection rate on the stability of faults. Experiments were conducted on a saw-cut sample of westerly granite. The experimental fault was 8 cm length. Injections were conducted through a 2 mm diameter hole reaching the fault surface. Experiments were conducted at four different order magnitudes fluid pressure injection rates (from 1 MPa/minute to 1 GPa/minute), in a fault system submitted to 50 and 100 MPa confining pressure. Our results show that the peak fluid pressure leading to slip depends on injection rate. The faster the injection rate, the larger the peak fluid pressure leading to instability. Wave velocity surveys across the fault highlighted that decreasing the injection-rate leads to an increase of size of the fluid pressure perturbation. Our result demonstrate that the stability of the fault is not only a function of the fluid pressure requires to reach the failure criterion, but is mainly a function of the ratio between the length of the fault affected by fluid pressure and the total fault length. In addition, we show that the slip rate increases with the background effective stress and with the intensity of the fluid pressure pertubation, i.e. with the excess shear stress acting on the part of the fault pertubated by fluid injection. Our results suggest that crustal fault can be reactivated by local high fluid overpressures. These results could explain the "large" magnitude human-induced earthquakes

  9. Experimental and computational fluid dynamics studies of mixing of complex oral health products

    Science.gov (United States)

    Cortada-Garcia, Marti; Migliozzi, Simona; Weheliye, Weheliye Hashi; Dore, Valentina; Mazzei, Luca; Angeli, Panagiota; ThAMes Multiphase Team

    2017-11-01

    Highly viscous non-Newtonian fluids are largely used in the manufacturing of specialized oral care products. Mixing often takes place in mechanically stirred vessels where the flow fields and mixing times depend on the geometric configuration and the fluid physical properties. In this research, we study the mixing performance of complex non-Newtonian fluids using Computational Fluid Dynamics models and validate them against experimental laser-based optical techniques. To this aim, we developed a scaled-down version of an industrial mixer. As test fluids, we used mixtures of glycerol and a Carbomer gel. The viscosities of the mixtures against shear rate at different temperatures and phase ratios were measured and found to be well described by the Carreau model. The numerical results were compared against experimental measurements of velocity fields from Particle Image Velocimetry (PIV) and concentration profiles from Planar Laser Induced Fluorescence (PLIF).

  10. Calculation of the force acting on a drop in a nonuniform flow of a current-supporting fluid

    International Nuclear Information System (INIS)

    Korovin, V.M.

    1993-01-01

    In the context of wide use of intense electric currents in various technological process, it is of practical interest to investigate the characteristics of the force action of electromagnetic fields on a variety of inclusions - solid particles, drops, gas bubbles - suspended in current-supporting fluids. In the available studies one treats the simplest case, in which the vortical component of the electromagnetic forces, generated by the interaction of the current with the internal magnetic field, is nonvanishing only in small vicinities near these inclusions, and therefore these electromagnetic forces do not generate global motion of the homogeneous current-supporting fluid. In practice, in most cases the vortical component of electromagnetic forces plays a substantial role in the whole operating region of the technological device, and the motion of the current-supporting fluid is created specifically by electromagnetic forces. In the case of a varying electromagnetic field the forces acting on particles are located in the conducting fluid, moving under the field action, were calculated by Korovim (Korovim, V. M., open-quotes The calculation of forces acting on suspended particles during the flow of a conducting fluid in a varying electromagnetic field,close quotes Magn. Gidrodin, No. 1 95-102 (1991)). In the present study the authors generalize the method suggested by Korovin for calculating forces applied to both drops and particles and gas bubbles suspended in the gradient flow of a fluid moving under the action of a constant electromagnetic field. 6 refs

  11. Non-Newtonian fluid structure interaction in flexible biomimetic microchannels

    Science.gov (United States)

    Kiran, M.; Dasgupta, Sunando; Chakraborty, Suman

    2017-11-01

    To investigate the complex fluid structure interactions in a physiologically relevant microchannel with deformable wall and non-Newtonian fluid that flows within it, we fabricated cylindrical microchannels of various softness out of PDMS. Experiments to measure the transient pressure drop across the channel were carried out with high sampling frequencies to capture the intricate flow physics. In particular, we showed that the waveforms varies greatly for each of the non-Newtonian and Newtonian cases for both non-deformable and deformable microchannels in terms of the peak amplitude, r.m.s amplitude and the crest factor. In addition, we carried out frequency sweep experiments to evaluate the frequency response of the system. We believe that these results will aid in the design of polymer based microfluidic phantoms for arterial FSI studies, and in particular for studying blood analog fluids in cylindrical microchannels as well as developing frequency specific Lab-on-chip systems for medical diagnostics.

  12. Particle-bearing currents in uniform density and two-layer fluids

    Science.gov (United States)

    Sutherland, Bruce R.; Gingras, Murray K.; Knudson, Calla; Steverango, Luke; Surma, Christopher

    2018-02-01

    Lock-release gravity current experiments are performed to examine the evolution of a particle bearing flow that propagates either in a uniform-density fluid or in a two-layer fluid. In all cases, the current is composed of fresh water plus micrometer-scale particles, the ambient fluid is saline, and the current advances initially either over the surface as a hypopycnal current or at the interface of the two-layer fluid as a mesopycnal current. In most cases the tank is tilted so that the ambient fluid becomes deeper with distance from the lock. For hypopycnal currents advancing in a uniform density fluid, the current typically slows as particles rain out of the current. While the loss of particles alone from the current should increase the current's buoyancy and speed, in practice the current's speed decreases because the particles carry with them interstitial fluid from the current. Meanwhile, rather than settling on the sloping bottom of the tank, the particles form a hyperpycnal (turbidity) current that advances until enough particles rain out that the relatively less dense interstitial fluid returns to the surface, carrying some particles back upward. When a hypopycnal current runs over the surface of a two-layer fluid, the particles that rain out temporarily halt their descent as they reach the interface, eventually passing through it and again forming a hyperpycnal current. Dramatically, a mesopycnal current in a two-layer fluid first advances along the interface and then reverses direction as particles rain out below and fresh interstitial fluid rises above.

  13. Structure of transformer oil-based magnetic fluids studied using acoustic spectroscopy

    International Nuclear Information System (INIS)

    Kúdelčík, Jozef; Bury, Peter; Drga, Jozef; Kopčanský, Peter; Závišová, Vlasta; Timko, Milan

    2013-01-01

    The structural changes in transformer oil-based magnetic fluids upon the effect of an external magnetic field and temperature were studied by acoustic spectroscopy. The attenuation of acoustic wave was measured as a function of the magnetic field in the range of 0–300 mT and in the temperature range of 15–35 °C for various magnetic nanoparticles concentrations. The effect of anisotropy of the acoustic attenuation was determined, too. The both strong influence of the magnetic field on the acoustic attenuation and its hysteresis were observed. When a magnetic field is increased, the interaction between the external magnetic field and the magnetic moments of the nanoparticles occurs, leading to the aggregation of magnetic nanoparticles and following clusters formation. However, the temperature of magnetic fluids also has very important influence on the structural changes because of the mechanism of thermal motion that acts against the cluster creation. The observed influences of both magnetic field and temperature on the investigated magnetic fluid structure are discussed. - Highlights: ► Structural changes in transformer oil-based magnetic fluids were investigated. ► The acoustic spectroscopy as the method of investigation was used. ► The influence of magnetic field on the structural was studied. ► The influence of temperatures on the structures was investigated, too. ► The influence of external conditions on the structure of MF is interpreted.

  14. Equilibrium and nonequilibrium dynamics of soft sphere fluids.

    Science.gov (United States)

    Ding, Yajun; Mittal, Jeetain

    2015-07-14

    We use computer simulations to test the freezing-point scaling relationship between equilibrium transport coefficients (self-diffusivity, viscosity) and thermodynamic parameters for soft sphere fluids. The fluid particles interact via the inverse-power potential (IPP), and the particle softness is changed by modifying the exponent of the distance-dependent potential term. In the case of IPP fluids, density and temperature are not independent variables and can be combined to obtain a coupling parameter to define the thermodynamic state of the system. We find that the rescaled coupling parameter, based on its value at the freezing point, can approximately collapse the diffusivity and viscosity data for IPP fluids over a wide range of particle softness. Even though the collapse is far from perfect, the freezing-point scaling relationship provides a convenient and effective way to compare the structure and dynamics of fluid systems with different particle softness. We further show that an alternate scaling relationship based on two-body excess entropy can provide an almost perfect collapse of the diffusivity and viscosity data below the freezing transition. Next, we perform nonequilibrium molecular dynamics simulations to calculate the shear-dependent viscosity and to identify the distinct role of particle softness in underlying structural changes associated with rheological properties. Qualitatively, we find a similar shear-thinning behavior for IPP fluids with different particle softness, though softer particles exhibit stronger shear-thinning tendency. By investigating the distance and angle-dependent pair correlation functions in these systems, we find different structural features in the case of IPP fluids with hard-sphere like and softer particle interactions. Interestingly, shear-thinning in hard-sphere like fluids is accompanied by enhanced translational order, whereas softer fluids exhibit loss of order with shear. Our results provide a systematic evaluation

  15. Correlation of cutting fluid performance in different machining operations

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Belluco, Walter

    2001-01-01

    An analysis of cutting fluid performance in different metal cutting operations is presented, based on experimental investigations in which type of operation, performance criteria, work material, and fluid type are considered. Cutting fluid performance was evaluated in turning, drilling, reaming...... investigated. Results show that correlation of cutting fluid performance in different operations exists, within the same group of cutting fluids, in the case of stainless steel as workpiece material. Under the tested conditions, the average correlation coefficients between efficiency parameters with different...... operations on austenitic stainless steel lied in the range 0.87-0.97 for waterbased fluids and 0.79-0.89 for straight oils. A similar correlation could not be found for the other workpiece materials investigated in this work. A rationalisation of cutting fluid performance tests is suggested....

  16. Shear-free perfect fluids with zero magnetic Weyl tensor

    International Nuclear Information System (INIS)

    Collins, C.B.

    1984-01-01

    Rotating, shear-free general-relativistic perfect fluids are investigated. It is first shown that, if the fluid pressure, p, and energy density, μ, are related by a barotropic equation of state p = p( μ) satifying μ+pnot =0, and if the magnetic part of the Weyl tensor (with respect to the fluid flow) vanishes, then the fluid's volume expansion is zero. The class of all such fluids is subsequently characterized. Further analysis of the solutions shows that, in general, the space-times may be regarded as being locally stationary and axisymmetric (they admit a two-dimensional Abelian isometry group with timelike orbits, which is in fact orthogonally transistive), although various specializations can occur, with the ''most special'' case being the well-known Goedel model, which is space-time homogeneous (it admits a five-dimensional isometry group acting multiply transitively on the space-time). all solutions are of Petrov type D. The fact that there are any solutions in the class at all means that a theorem appearing in the literature is invalid, and the existence of some special solutions in which the fluid's vorticity vector is orthogonal to the acceleration reveals the incompleteness of a previous study of a class of space-times, in which there are Killing vectors parallel to the fluid four-velocity and to the vorticity vector

  17. Natural frequency analysis of fluid conveying pipeline with different boundary conditions

    International Nuclear Information System (INIS)

    Huang Yimin; Liu Yongshou; Li Baohui; Li Yanjiang; Yue Zhufeng

    2010-01-01

    In this study, the natural frequency of fluid-structure interaction in pipeline conveying fluid is investigated by eliminated element-Galerkin method, and the natural frequency equations with different boundary conditions are obtained. Furthermore, the expressions of first natural frequency are simplified in the case of different boundary conditions. Taking into account the Coriolis force, as an example, the natural frequency of a straight pipe simply supported at both ends is studied. In a given boundary condition, the four components (mass, stiffness, length and flow velocity) which relate to the natural frequency of pipeline conveying fluid are studied in detail and the results indicate that the effect of Coriolis force on natural frequency is inappreciable. Then the relationship between natural frequency of the pipeline conveying fluid and that of Euler beam is analyzed. Finally, a dimensionless flow velocity and limit values are presented, and they can be used to estimate the effect of the flow velocity on natural frequency. All the conclusions are well suited to nuclear plant and other industry fields.

  18. Bacterial Meningitis in the Absence of Cerebrospinal Fluid Pleocytosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Ryota Hase

    2014-01-01

    Full Text Available Elevation of cerebrospinal fluid (CSF cell count is a key sign in the diagnosis of bacterial meningitis. However, there have been reports of bacterial meningitis with no abnormalities in initial CSF testing. This type of presentation is extremely rare in adult patients. Here, a case involving an 83-year-old woman who was later diagnosed with bacterial meningitis caused by Neisseria meningitidis is described, in whom CSF at initial and second lumbar puncture did not show elevation of cell counts. Twenty-six non-neutropenic adult cases of bacterial meningitis in the absence of CSF pleocytosis were reviewed. The frequent causative organisms were Streptococcus pneumoniae and N meningitidis. Nineteen cases had bacteremia and seven died. The authors conclude that normal CSF at lumbar puncture at an early stage cannot rule out bacterial meningitis. Therefore, repeat CSF analysis should be considered, and antimicrobial therapy must be started immediately if there are any signs of sepsis or meningitis.

  19. Theoretical study of the flow in a fluid damper containing high viscosity silicone oil: Effects of shear-thinning and viscoelasticity

    Science.gov (United States)

    Syrakos, Alexandros; Dimakopoulos, Yannis; Tsamopoulos, John

    2018-03-01

    The flow inside a fluid damper where a piston reciprocates sinusoidally inside an outer casing containing high-viscosity silicone oil is simulated using a finite volume method, at various excitation frequencies. The oil is modeled by the Carreau-Yasuda (CY) and Phan-Thien and Tanner (PTT) constitutive equations. Both models account for shear-thinning, but only the PTT model accounts for elasticity. The CY and other generalised Newtonian models have been previously used in theoretical studies of fluid dampers, but the present study is the first to perform full two-dimensional (axisymmetric) simulations employing a viscoelastic constitutive equation. It is found that the CY and PTT predictions are similar when the excitation frequency is low, but at medium and higher frequencies, the CY model fails to describe important phenomena that are predicted by the PTT model and observed in experimental studies found in the literature, such as the hysteresis of the force-displacement and force-velocity loops. Elastic effects are quantified by applying a decomposition of the damper force into elastic and viscous components, inspired from large amplitude oscillatory shear theory. The CY model also overestimates the damper force relative to the PTT model because it underpredicts the flow development length inside the piston-cylinder gap. It is thus concluded that (a) fluid elasticity must be accounted for and (b) theoretical approaches that rely on the assumption of one-dimensional flow in the piston-cylinder gap are of limited accuracy, even if they account for fluid viscoelasticity. The consequences of using lower-viscosity silicone oil are also briefly examined.

  20. Acute gouty bursitis: report of 15 cases.

    Science.gov (United States)

    Canoso, J J; Yood, R A

    1979-01-01

    Fifteen cases of acute gouty bursitis were seen among 136 crystal-proved cases of gout. Bursal aspirate yielded yellow or pink fluid in 10, chalky white fluid in 1, and a small amount of bloody fluid in 4. Monosodium urate crystals were present in all. Bursal fluid leucocyte counts averaged 2.9 X 10(9)/1 compared with synovial fluid leucocyte counts that averaged 25.5 X 10(9)/1 in cases of articular gout (P less than 0.05). Gouty, septic, and idiopathic (traumatic) bursitis share clinical features, and detailed bursal fluid analysis is crucial for diagnosis. PMID:496446

  1. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    Science.gov (United States)

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  2. Study of high-pressure adsorption from supercritical fluids by the potential theory

    DEFF Research Database (Denmark)

    Monsalvo, Matias Alfonso; Shapiro, Alexander

    2009-01-01

    The multicomponent potential theory of adsorption (MPTA), which has been previously used to study low-pressure adsorption of subcritical fluids, is extended to adsorption equilibria from supercritical fluids up to high pressures. The MPTA describes an adsorbed phase as an inhomogeneous fluid...... the adsorbed and the gas phases. We have also evaluated the performance of the classical Soave-Redlich-Kwong (SRK) EoS. The fluid-solid interactions are described by simple Dubinin-Radushkevich-Astakhov (DRA) potentials. In addition, we test the performance of the 10-4-3 Steele potential. It is shown...... that application of sPC-SAFT slightly improves the performance of the MPTA and that in spite of its simplicity, the DRA model can be considered as an accurate potential, especially, for mixture adsorption. We show that, for the sets of experimental data considered in this work, the MPTA is capable of predicting...

  3. An industrial perspective on bioreactor scale-down: what we can learn from combined large-scale bioprocess and model fluid studies.

    Science.gov (United States)

    Noorman, Henk

    2011-08-01

    For industrial bioreactor design, operation, control and optimization, the scale-down approach is often advocated to efficiently generate data on a small scale, and effectively apply suggested improvements to the industrial scale. In all cases it is important to ensure that the scale-down conditions are representative of the real large-scale bioprocess. Progress is hampered by limited detailed and local information from large-scale bioprocesses. Complementary to real fermentation studies, physical aspects of model fluids such as air-water in large bioreactors provide useful information with limited effort and cost. Still, in industrial practice, investments of time, capital and resources often prohibit systematic work, although, in the end, savings obtained in this way are trivial compared to the expenses that result from real process disturbances, batch failures, and non-flyers with loss of business opportunity. Here we try to highlight what can be learned from real large-scale bioprocess in combination with model fluid studies, and to provide suitable computation tools to overcome data restrictions. Focus is on a specific well-documented case for a 30-m(3) bioreactor. Areas for further research from an industrial perspective are also indicated. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. One case of Trichomonas vaginalis in pleural fluid%胸水中检出阴道毛滴虫1例

    Institute of Scientific and Technical Information of China (English)

    范久波; 刘海菊; 王荣; 陈斌

    2009-01-01

    本文报道1例从胸水中检出阴道毛滴虫的病例.患者治疗不彻底,因心肺衰竭而死亡.%This paper reports a case of Trichomonas vaginalis detected from pleural fluid. Because of inadequate treatment, the patient died due to heart and lung failure.

  5. A field application of nanoparticle-based invert emulsion drilling fluids

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, Alexey S.; Husein, Maen, E-mail: mhusein@ucalgary.ca [University of Calgary, Department of Chemical & Petroleum Engineering (Canada); Hareland, Geir [Oklahoma State University, Department of Chemical Engineering (United States)

    2015-08-15

    Application of nanotechnology in drilling fluids for the oil and gas industry has been a focus of several recent studies. A process for the in situ synthesis of nanoparticles (NPs) into drilling fluids has been developed previously in our group and showed that calcium-based NPs (CNPs) and iron-based NPs (INPs), respectively, with concentrations of 0.5–2.0 wt% can dramatically improve filtration properties of commercial drilling fluids in a laboratory environment. In this work, a modified process for the emulsion-based synthesis of NPs on a 20 m{sup 3} volume and its subsequent full-scale field testing are presented. Comparison between NP carrier fluids prepared under controlled environment in the laboratory and those prepared on a large scale in a mixing facility revealed very little variation in the main characteristics of the drilling fluid; including the size of the solid constituents. Transmission electron microscopy photographs suggest an average CNP particle size in the carrier fluid of 51 ± 11 nm. Results from the full-scale field test showed that total mud losses while drilling with CNP-based invert emulsion were on average 27 % lower than in the case of conventional fluids. This loss prevention falls within the range observed in the laboratory.

  6. A sealed turbo-alternator using any working-fluid

    International Nuclear Information System (INIS)

    Chollet, Maurice.

    1973-01-01

    The invention relates to a sealed turbo-alternator operating with a working fluid other than water. The turbo-alternator and the feed and lubricating pumps thereof are housed in a sealed casing. The latter constitutes, with the heat pump and the heat sink, a sealed enclosure containing the working and lubricating fluid. The alternator, which comprises neither collector nor brushes, is dipped in the working fluid vapor. Electric energy leaves the sealed enclosure through insulating sealed passager. In view of the absence of leakage it is possible to select (e.g. among freons) a working fluid well suited to the temperature differential between the heat source and the heat sink, and, accordingly to use temperature drops which could be too small in the case of steam. The various applications are as follows: recovery of calories at the exhaust of diesels and of gas turbines or in the cooling water of diesels; equipment of isotopic generators; recovery of calories from factory waste thrown into rivers (anti-pollution effect in view of the lowering of water temperature); non-polluting engine for special electrical vehicles [fr

  7. Boundary control of fluid flow through porous media

    DEFF Research Database (Denmark)

    Hasan, Agus; Foss, Bjarne; Sagatun, Svein Ivar

    2010-01-01

    The flow of fluids through porous media can be described by the Boussinesq’s equation with mixed boundary conditions; a Neumann’s boundary condition and a nonlinear boundary condition. The nonlinear boundary condition provides a means to control the fluid flow through porous media. In this paper,......, some stabilizing controllers are constructed for various cases using Lyapunov design.......The flow of fluids through porous media can be described by the Boussinesq’s equation with mixed boundary conditions; a Neumann’s boundary condition and a nonlinear boundary condition. The nonlinear boundary condition provides a means to control the fluid flow through porous media. In this paper...

  8. The 1H NMR profile of healthy dog cerebrospinal fluid.

    Directory of Open Access Journals (Sweden)

    Mihai Musteata

    Full Text Available The availability of data for reference values in cerebrospinal fluid for healthy humans is limited due to obvious practical and ethical issues. The variability of reported values for metabolites in human cerebrospinal fluid is quite large. Dogs present great similarities with humans, including in cases of central nervous system pathologies. The paper presents the first study on healthy dog cerebrospinal fluid metabolomic profile using (1H NMR spectroscopy. A number of 13 metabolites have been identified and quantified from cerebrospinal fluid collected from a group of 10 mix breed healthy dogs. The biological variability as resulting from the relative standard deviation of the physiological concentrations of the identified metabolites had a mean of 18.20% (range between 9.3% and 44.8%. The reported concentrations for metabolites may be used as normal reference values. The homogeneity of the obtained results and the low biologic variability show that the (1H NMR analysis of the dog's cerebrospinal fluid is reliable in designing and interpreting clinical and therapeutic trials in dogs with central nervous system pathologies.

  9. Does the Ventrica magnetic vascular positioner (MVP) for coronary artery bypass grafting significantly alter local fluid dynamics? A numeric study.

    Science.gov (United States)

    Morbiducci, U; Lemma, M; Ponzini, R; Boi, A; Bondavalli, L; Antona, C; Montevecchi, F M; Redaelli, A

    2007-07-01

    Automatic devices have been recently introduced to make the anastomosis procedure quick and efficient when creating a coronary bypass on the beating heart. However, the implantation of these devices could modify the graft configuration, consistently affecting the hemodynamics usually found in the traditional anastomosis. As local fluid dynamics could play a significant role in the onset of vessel wall pathologies, in this article a computational approach was designed to investigate flow patterns in the presence of the Ventrica magnetic vascular positioner (Ventrica MVP) device. A model of standard hand-sewn anastomosis and of automated magnetic anastomosis were constructed, and the finite volume method was used to simulate in silico realistic graft hemodynamics. Synthetic analytical descriptors -- i.e., time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and helical flow index (HFI) -- were calculated and compared for quantitative assessment of the anastomosis geometry hemodynamic performance. In this case study, the same most critical region was identified for the 2 models as the one with the lowest TAWSS and the highest OSI (TAWSS=0.229, OSI=0.255 for the hand-sewn anastomosis; TAWSS=0.297, OSI=0.171 for the Ventrica MVP(R)). However, the shape of the Ventrica MVP does not induce more critical wall shear stresses, oscillating flow and damped helicity in the graft fluid dynamics, as compared with conventional anastomosis. We found that the use of the Ventrica MVP for the case study under investigation was not associated with more critical fluid dynamics than with conventional hand-sewn anastomosis. Thereby, the device could facilitate beating heart and minimally invasive coronary artery bypass grafting without increasing local hemodynamic-related risks of failure.

  10. Flapping motion and force generation in a viscoelastic fluid

    Science.gov (United States)

    Normand, Thibaud; Lauga, Eric

    2008-12-01

    In a variety of biological situations, swimming cells have to move through complex fluids. Similarly, mucociliary clearance involves the transport of polymeric fluids by beating cilia. Here, we consider the extent to which complex fluids could be exploited for force generation on small scales. We consider a prototypical reciprocal motion (i.e., identical under time-reversal symmetry): the periodic flapping of a tethered semi-infinite plane. In the Newtonian limit, such motion cannot be used for force generation according to Purcell’s scallop theorem. In a polymeric fluid (Oldroyd-B, and its generalization), we show that this is not the case and calculate explicitly the forces on the flapper for small-amplitude sinusoidal motion. Three setups are considered: a flapper near a wall, a flapper in a wedge, and a two-dimensional scalloplike flapper. In all cases, we show that at quadratic order in the oscillation amplitude, the tethered flapping motion induces net forces, but no average flow. Our results demonstrate therefore that the scallop theorem is not valid in polymeric fluids. The reciprocal component of the movement of biological appendages such as cilia can thus generate nontrivial forces in polymeric fluid such as mucus, and normal-stress differences can be exploited as a pure viscoelastic force generation and propulsion method.

  11. Novel use of an ultrafiltration device as an alternative method for fluid removal in critically ill pediatric patients with cardiac disease: a case series

    Directory of Open Access Journals (Sweden)

    Sujata Chakravarti

    2016-06-01

    Full Text Available Fluid overload (FO is a common complication for pediatric patients in the intensive care unit. When conventional therapy fails, hemodialysis or peritoneal dialysis is classically used for fluid removal. Unfortunately, these therapies are often associated with cardiovascular or respiratory instability. Ultrafiltration, using devices such as the AquadexTM system (Baxter Healthcare, Deerfield, IL, USA, is an effective tool for fluid removal in adult patients with congestive heart failure. As compared to hemodialysis, ultrafiltration can be performed using smaller catheters, and the extracorporeal volume and minimal blood flow rates are lower. In addition, there is no associated abdominal distension as is seen in peritoneal dialysis. Consequently, ultrafiltration may be better tolerated in critically ill pediatric patients. We present three cases of challenging pediatric patients with FO in the setting of congenital heart disease in whom ultrafiltration using the AquadexTM system was successfully utilized for fluid removal while cardiorespiratory stability was maintained.

  12. On perfect fluids and black holes in static equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco, Alberto; Mars, Marc; Simon, Walter [Facultad de Ciencias, Universidad de Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain)

    2007-05-15

    Proofs of spherical symmetry of static black holes and of spherical symmetry of static perfect fluids normally require, a priori, 'black holes only' or 'fluid only'. In a recent paper Shiromizu, Yamada and Yoshino admit a priori (and exclude) coexistence of fluids and holes. This work assumes connectedness of the fluid region and the same assumptions on the equation of state as earlier papers on the 'fluid only' case, and requires in addition an upper bound for the fluid mass in terms of the black holes masses. We discuss this paper. As a new result we show that there cannot exist static fluid shells (i.e. fluid regions of the topology of an annulus) even if one a priori admits, inside and outside the shell, any arrangement of black holes or additional matter which satisfies the energy condition.

  13. Parametric electroconvection in a weakly conducting fluid in a horizontal parallel-plate capacitor

    International Nuclear Information System (INIS)

    Kartavykh, N. N.; Smorodin, B. L.; Il’in, V. A.

    2015-01-01

    We study the flows of a nonuniformly heated weakly conducting fluid in an ac electric field of a horizontal parallel-plate capacitor. Analysis is carried out for fluids in which the charge formation is governed by electroconductive mechanism associated with the temperature dependence of the electrical conductivity of the medium. Periodic and chaotic regimes of fluid flow are investigated in the limiting case of instantaneous charge relaxation and for a finite relaxation time. Bifurcation diagrams and electroconvective regimes charts are constructed. The regions where fluid oscillations synchronize with the frequency of the external field are determined. Hysteretic transitions between electroconvection regimes are studied. The scenarios of transition to chaotic oscillations are analyzed. Depending on the natural frequency of electroconvective system and the external field frequency, the transition from periodic to chaotic oscillations can occur via quasiperiodicity, a subharmonic cascade, or intermittence

  14. Parametric electroconvection in a weakly conducting fluid in a horizontal parallel-plate capacitor

    Energy Technology Data Exchange (ETDEWEB)

    Kartavykh, N. N.; Smorodin, B. L., E-mail: bsmorodin@yandex.ru; Il’in, V. A. [Perm State National Research University (Russian Federation)

    2015-07-15

    We study the flows of a nonuniformly heated weakly conducting fluid in an ac electric field of a horizontal parallel-plate capacitor. Analysis is carried out for fluids in which the charge formation is governed by electroconductive mechanism associated with the temperature dependence of the electrical conductivity of the medium. Periodic and chaotic regimes of fluid flow are investigated in the limiting case of instantaneous charge relaxation and for a finite relaxation time. Bifurcation diagrams and electroconvective regimes charts are constructed. The regions where fluid oscillations synchronize with the frequency of the external field are determined. Hysteretic transitions between electroconvection regimes are studied. The scenarios of transition to chaotic oscillations are analyzed. Depending on the natural frequency of electroconvective system and the external field frequency, the transition from periodic to chaotic oscillations can occur via quasiperiodicity, a subharmonic cascade, or intermittence.

  15. Induced fluid rotation and bistable fluidic turn-down valves (a survey

    Directory of Open Access Journals (Sweden)

    Tesař Václav

    2015-01-01

    Full Text Available Paper surveys engineering applications of an unusual fluidic principle — momentum transfer through a relatively small communicating window into a vortex chamber, where the initially stationary fluid is put into rotation. The transfer is often by shear stress acting in the window plane, but may be enhanced and perhaps even dominated by fluid flow crossing the boundary. The case of zero-time-mean fluid transport through the window has found use in experimental fluid mechanics: non-invasive measurement of wall shear stress on objects by evaluating the induced rotation in the vortex chamber. The case with the non-zero flow through the interface became the starting point in development of fluidic valves combining two otherwise mutually incompatible properties: bistability and flow turning down.

  16. The Study Of Deactivation And Regeneration Of A Fluid Cracking ...

    African Journals Online (AJOL)

    The Study Of Deactivation And Regeneration Of A Fluid Cracking Zeolite Catalysts. ... The catalytic activities of modified and unmodified sodium Y-Zeolites catalysts ... sample was seen to completely restore the catalytic activity of both samples.

  17. The Rayleigh-Taylor instability in a self-gravitating two-layer fluid sphere

    International Nuclear Information System (INIS)

    Ida, Shigeru; Nakagawa, Yoshitsugu; Nakazawa, Kiyoshi

    1989-01-01

    The Rayleigh-Taylor instability is studied in a self-gravitating two-layer fluid sphere: an inner sphere and an outer layer. The density and the viscosity are assumed to be constant in each region. Analytic expressions of the dispersion relations are obtained in inviscid and viscid cases. This examination aims at the investigation of the Earth's core formation. The fluid sphere corresponds to the proto-Earth in the accretion stage. The instability is examined without rotation of the fluid sphere, while the proto-Earth is rotating. However, it is shown that the Coriolis force does not influence the conclusion in the Earth's core formation problem. 5 refs.; 10 figs

  18. Biorheological Model on Flow of Herschel-Bulkley Fluid through a Tapered Arterial Stenosis with Dilatation

    Directory of Open Access Journals (Sweden)

    S. Priyadharshini

    2015-01-01

    Full Text Available An analysis of blood flow through a tapered artery with stenosis and dilatation has been carried out where the blood is treated as incompressible Herschel-Bulkley fluid. A comparison between numerical values and analytical values of pressure gradient at the midpoint of stenotic region shows that the analytical expression for pressure gradient works well for the values of yield stress till 2.4. The wall shear stress and flow resistance increase significantly with axial distance and the increase is more in the case of converging tapered artery. A comparison study of velocity profiles, wall shear stress, and flow resistance for Newtonian, power law, Bingham-plastic, and Herschel-Bulkley fluids shows that the variation is greater for Herschel-Bulkley fluid than the other fluids. The obtained velocity profiles have been compared with the experimental data and it is observed that blood behaves like a Herschel-Bulkley fluid rather than power law, Bingham, and Newtonian fluids. It is observed that, in the case of a tapered stenosed tube, the streamline pattern follows a convex pattern when we move from r/R=0 to r/R=1 and it follows a concave pattern when we move from r/R=0 to r/R=-1. Further, it is of opposite behaviour in the case of a tapered dilatation tube which forms new information that is, for the first time, added to the literature.

  19. Present State and Future Developments in Mechatronics and it's Influence on Fluid Power Systems

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg; Zhou, Jianjun; Conrad, Finn

    1998-01-01

    with electronics, software and mechanics. This synergetic integration is often called Mechatronics.The topic which is rather widespread will be treated in three sections: I) General overview of mechatronics and fluid power. In this section the general trends of mechatronics in fluid power is considered by relating...... trends in the neighbouring fields of software and electronic hardware to fluid power developments. II) Mechatronic case stories from IKS In this section the results of a conceptual design study : "Design of a frequency converter based hydraulic power supply" is presented together with a more detailed...

  20. The effects of umbilical cord entanglement upon labor management and fetal health: retrospective case control study.

    Science.gov (United States)

    Buyukkayaci Duman, Nuriye; Topuz, Senay; Bostanci, Mehmet Omer; Gorkem, Umit; Yuksel Kocak, Derya; Togrul, Cihan; Gungor, Tayfun

    2018-03-01

    This retrospective study aimed at determining prognostic factors that paved the way for umbilical cord entanglement (UCE) and the effects of UCE upon labor management and fetal health. Sixty women who gave term birth with head presentation and received UCE diagnosis following birth composed the case group while another 60 women with the same characteristics who were selected with randomized sampling method and who did not develop UCE comprised the control group. The data obtained were processed with SPSS 22.0 statistical program. T test was used for comparing demographic and obstetric data and mean birth weight of babies in the case group and control group. For comparing data on active labor management and fetal health, numbers, percentages and chi-square test were used. Also for comparing values case: 58.3.0%; control: 21.7%), vacuum assisted vaginal delivery (case: 20.0%; control: 3.3%), forceps assisted vaginal delivery (case: 8.3%; control: 1.7%), fetal distress (case: 60.0%; control: 25.0%), amniotic fluid meconium (case: 58.3%; control: 21.7%), APGAR score less than 7 at the 1st minute (case: 58.3%; control: 21.7%) and APGAR score less than 7 at the 5th minute were higher in the women in the case group than the women in the control group (p < 0.05). UCE increased rates of interventional birth, emergent cesarean delivery, vacuum assisted vaginal delivery, forceps assisted vaginal delivery, amniotic fluid meconium and fetal distress.

  1. Lattice Boltzmann model for three-phase viscoelastic fluid flow

    Science.gov (United States)

    Xie, Chiyu; Lei, Wenhai; Wang, Moran

    2018-02-01

    A lattice Boltzmann (LB) framework is developed for simulation of three-phase viscoelastic fluid flows in complex geometries. This model is based on a Rothman-Keller type model for immiscible multiphase flows which ensures mass conservation of each component in porous media even for a high density ratio. To account for the viscoelastic effects, the Maxwell constitutive relation is correctly introduced into the momentum equation, which leads to a modified lattice Boltzmann evolution equation for Maxwell fluids by removing the normal but excess viscous term. Our simulation tests indicate that this excess viscous term may induce significant errors. After three benchmark cases, the displacement processes of oil by dispersed polymer are studied as a typical example of three-phase viscoelastic fluid flow. The results show that increasing either the polymer intrinsic viscosity or the elastic modulus will enhance the oil recovery.

  2. CT findings of subdural fluid collections and the histology of the organized neomembrane, (1)

    International Nuclear Information System (INIS)

    Shibata, Taichiro; Nitta, Masahiro; Fukuoka, Hidekazu; Umemura, Satoshi; Nagai, Hajime

    1981-01-01

    Recently it has been reported that, among cases of subdural fluid collection with a low CT density with several weeks after injury, some of the cases developed a chronic subdural hematoma at the same location several months later. On its pathogenesis, it is assumed that the isolated fluid collection between the dura and arachnoid forms a neomembrane and then develops a chronic subdural hematoma. Based upon our 4 cases of subdural fluid collection, we pointed out that the following conditions of subdural low-density lesions are difficult to differentiate from subdural hydroma at the early stage of injury: (1) The existence of a very old chronic subdural hematoma that might have been formed before the recent injury. (2) The occurrence of a minor hemorrhage into the subdural-fluid collection at the time of injury, which is indistinguishable on the CT scan. Therefore, the present authors considered it necessary to investigate the histology of the hematoma membrane in order to make clear the formation process of neomembrane and to compare the relation between the aging of neomembrane and the time interval of injury and CT examination. We consider the histological study very useful to reveal the pathogenesis of a chronic subdural hematoma, for it will make clear the following points: (1) Whether the neomembrane had already been formed prior to the recent head injury, (2) Whether the neomembrane was formed newly due to minor hemorrhage into the subdural fluid collection, and (3) Whether the formation of the neomembrane is possible simply from subdural-fluid collection isolated from the CSF pathway. (author)

  3. Noether and Lie symmetries for charged perfect fluids

    International Nuclear Information System (INIS)

    Kweyama, M C; Govinder, K S; Maharaj, S D

    2011-01-01

    We study the underlying nonlinear partial differential equation that governs the behaviour of spherically symmetric charged fluids in general relativity. We investigate the conditions for the equation to admit a first integral or be reduced to quadratures using symmetry methods for differential equations. A general Noether first integral is found. We also undertake a comprehensive group analysis of the underlying equation using Lie point symmetries. The existence of a Lie symmetry is subject to solving an integro-differential equation in general; we investigate the conditions under which it can be reduced to quadratures. Earlier results for uncharged fluids and particular first integrals for charged matter are regained as special cases of our treatment.

  4. Experimental study and CFD simulation of rotational eccentric cylinder in a magnetorheological fluid

    Science.gov (United States)

    Omidbeygi, F.; Hashemabadi, S. H.

    2012-07-01

    In this study, a magnetorheological (MR) fluid is prepared using carbonyl iron filings and low viscosity lubricating oil. The effects of magnetic field and weight percentage of particles on the viscosity of the MR fluid have been measured using a rotational viscometer. The yield stress under an applied magnetic field was also obtained experimentally. In the absence of an applied magnetic field, the MR fluid behaves as a Newtonian fluid. When the magnetic field is applied, the MR fluid behaves like Bingham plastics with a magnetic field dependent yield stress. Afterward, the results compared with those of CFD simulation of two eccentric cylinders in the MR fluid. Results show that the influences of MR effects, caused by the applied magnetic field, on the model characteristics are significant and not negligible. The viscosity is enhanced by increasing of the magnetic field, eccentricity ratio and weight percentage of suspensions. The MR effects and increasing of weight percentage and eccentricity ratio also provide an enhancement in the yield stresses and required total torque for rotation of inner cylinder. Also the simulation results indicate a good representation of the experiment by the model.

  5. Frontoethmoidal Schwannoma with Exertional Cerebrospinal Fluid Rhinorrhea: Case Report and Review of Literature.

    Science.gov (United States)

    Yoneoka, Yuichiro; Akiyama, Katsuhiko; Seki, Yasuhiro; Hasegawa, Go; Kakita, Akiyoshi

    2018-03-01

    Frontoethmoidal schwannomas are rare. No case manifesting exertional cerebrospinal fluid (CSF) rhinorrhea has ever been reported to the best of our knowledge. In this report, we describe an extremely rare case of frontoethmoidal schwannoma extending through the olfactory groove with exertional CSF rhinorrhea as the initial symptom. A 50-year-old woman was presented to our clinic for frequent nasal discharge on exertion. A postcontrast computed tomographic scan demonstrated heterogeneously enhanced tumor from the anterior cranial fossa to the anterior ethmoid sinus. A gadolinium-enhanced T1-weighted magnetic resonance image revealed a well-defined heterogeneously enhanced tumor situated in the midline anterior cranial fossa and anterior ethmoid sinus. After the resection, the defect of the right anterior skull base was reconstructed with a fascia graft and adipose tissue taken from the abdomen, as well as a pedicle periosteum flap. A histologic examination revealed the tumor as schwannoma. Her rhinorrhea completely resolved. She regained her sense of smell and taste 1 month after the operation. According to previous reports, olfactory groove, and paraolfactory groove/periolfactory groove schwannomas can be divided into 4 types: subfrontal, nasoethmoidal, frontoethmoidal, and ethmofrontal. Among them, a frontoethmoidal schwannoma can manifest exertional CSF rhinorrhea as an initial symptom. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Thanatochemistry: Study of synovial fluid potassium

    African Journals Online (AJOL)

    Nilesh Keshav Tumram

    2014-03-28

    Mar 28, 2014 ... Medical College & Hospital, Nagpur, Maharashtra 440003, India b Dean, Govt. ... interval and postmortem biochemical changes in various body fluids such .... likely to have technical errors than other methods adopted till date.

  7. Diffuse-Interface Methods in Fluid Mechanics

    Science.gov (United States)

    Anderson, D. M.; McFadden, G. B.; Wheeler, A. A.

    1997-01-01

    The authors review the development of diffuse-interface models of hydrodynamics and their application to a wide variety of interfacial phenomena. The authors discuss the issues involved in formulating diffuse-interface models for single-component and binary fluids. Recent applications and computations using these models are discussed in each case. Further, the authors address issues including sharp-interface analyses that relate these models to the classical free-boundary problem, related computational approaches to describe interfacial phenomena, and related approaches describing fully-miscible fluids.

  8. Investigation and clinical applications of muscle strength change in cerebrospinal fluid tap test in cases of idiopathic normal pressure hydrocephalus: A retrospective study.

    Science.gov (United States)

    Matsuoka, Tsuyoshi; Iida, Jun-Ichi; Kawahara, Makoto; Uchiyama, Yoshitomo

    2016-12-15

    The cerebrospinal fluid tap test (CSFTT) is widely used to diagnose idiopathic normal pressure hydrocephalus (iNPH) and predict the therapeutic effectiveness of shunting. However, the ability to walk cannot be quantified for patients who are unable to walk. Therefore, we examined whether the iNPH diagnostic aid is possible using dynamometry, even for patients who are unable to walk. In this study, 45 patients underwent grip strength assessment, quadriceps strength assessment, 10-m walk test, and 3-m Timed Up and Go test before and after CSFTT. Our investigation of physical functions indicated that the CSFTT-positive group demonstrated significant improvements in grip and bilateral quadriceps muscle strength. The results of the receiver operating characteristic analysis indicated that leg muscle strength measurement reliability was high and that the area under the curve was 0.754-0.811. Our investigation of the clinically effective cutoff point for the rate of change indicated that it was 13.6% for right quadriceps muscle strength and 15.3% for left quadriceps muscle strength. Comparing CSFTT results in cases of iNPH with the observed rate of change in muscle strength can aid in the diagnosis of iNPH. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Energy effects on the structure and thermodynamic properties of nanoconfined fluids (a density functional theory study).

    Science.gov (United States)

    Keshavarzi, Ezat; Kamalvand, Mohammad

    2009-04-23

    The structure and properties of fluids confined in nanopores may show a dramatic departure from macroscopic bulk fluids. The main reason for this difference lies in the influence of system walls. In addition to the entropic wall effect, system walls can significantly change the energy of the confined fluid compared to macroscopic bulk fluids. The energy effect of the walls on a nanoconfined fluid appears in two forms. The first effect is the cutting off of the intermolecular interactions by the walls, which appears for example in the integrals for calculation of the thermodynamic properties. The second wall effect involves the wall-molecule interactions. In such confined fluids, the introduction of wall forces and the competition between fluid-wall and fluid-fluid forces could lead to interesting thermodynamic properties, including new kinds of phase transitions not observed in the macroscopic fluid systems. In this article, we use the perturbative fundamental measure density functional theory to study energy effects on the structure and properties of a hard core two-Yukawa fluid confined in a nanoslit. Our results show the changes undergone by the structure and phase transition of the nanoconfined fluids as a result of energy effects.

  10. Structure of transformer oil-based magnetic fluids studied using acoustic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kudelcik, Jozef, E-mail: kudelcik@fyzika.uniza.sk [Department of Physics, University of Zilina, Univerzitna 1, 010 01 Zilina (Slovakia); Bury, Peter; Drga, Jozef [Department of Physics, University of Zilina, Univerzitna 1, 010 01 Zilina (Slovakia); Kopcansky, Peter; Zavisova, Vlasta; Timko, Milan [Department of Magnetism, IEP SAS, Watsonova 47, 040 01 Kosice (Slovakia)

    2013-01-15

    The structural changes in transformer oil-based magnetic fluids upon the effect of an external magnetic field and temperature were studied by acoustic spectroscopy. The attenuation of acoustic wave was measured as a function of the magnetic field in the range of 0-300 mT and in the temperature range of 15-35 Degree-Sign C for various magnetic nanoparticles concentrations. The effect of anisotropy of the acoustic attenuation was determined, too. The both strong influence of the magnetic field on the acoustic attenuation and its hysteresis were observed. When a magnetic field is increased, the interaction between the external magnetic field and the magnetic moments of the nanoparticles occurs, leading to the aggregation of magnetic nanoparticles and following clusters formation. However, the temperature of magnetic fluids also has very important influence on the structural changes because of the mechanism of thermal motion that acts against the cluster creation. The observed influences of both magnetic field and temperature on the investigated magnetic fluid structure are discussed. - Highlights: Black-Right-Pointing-Pointer Structural changes in transformer oil-based magnetic fluids were investigated. Black-Right-Pointing-Pointer The acoustic spectroscopy as the method of investigation was used. Black-Right-Pointing-Pointer The influence of magnetic field on the structural was studied. Black-Right-Pointing-Pointer The influence of temperatures on the structures was investigated, too. Black-Right-Pointing-Pointer The influence of external conditions on the structure of MF is interpreted.

  11. Principles of fluid-structure interaction

    International Nuclear Information System (INIS)

    Schumann, U.; Kernforschungszentrum Karlsruhe G.m.b.H.

    1981-01-01

    Fluid-structure interaction (FSI) is an important physical phenomenon which has attracted significant attention in nuclear reactor safety analysis. Here, simple explanations of the principle effects of FSI are given and illustrated by reference to numerical and experimental results. First, a very simple fluid-structure model is introduced which consists of a spring supported piston closing a fluid filled rigid pipe. The motion of the piston and the fluid is approximately described by one degree of freedom, respectively. Depending on the load frequency and material parameters one finds that the coupled system is characterized by virtual masses and stiffnesses or by the inverse properties which are termed virtual fluidities and compressibilities. Thus the two parts interact as if they are connected in series or in parallel. The two eigenfrequencies of the coupled system enclose the eigenfrequencies of the individual fluid and structure parts. Second, the great importance of Hamilton's principle for derivation of the coupled equations of motion is emphasized. From this principle upper and lower bounds for the effective density of a heterogeneous fluid-solid mixture are deduced. Continuum models for such mixtures contain a virtual density tensor. Finally, we discuss FSI for the case of a loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR) in the first (subcooled) blowdown period. Here, the fluid imposes pressure loadings on internal structures like the core barrel and the motion of these structures influences the fluid motion. Recent experimental results obtained at the HDR are compared with numerical predictions of the FLUX 2-code. The fair agreement confirms that we have well understood the principal effects of FSI. (orig.) [de

  12. Fluid Signal Intensity That Mimicked A Supraspinatus Tendon Tear In A Subacromial Injected Shoulder: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hun; Kim, Tae Eun; Shin, Hyun Woong [Daegu Fatima Hospital, Daegu (Korea, Republic of)

    2010-06-15

    Subacromial steroid injections are a common procedure for treating shoulder pain. Several studies have reported on the difficulty of performing an accurate injection into the subacromial bursa, as well as the injected material infiltrated into other regional structures even when an accurate injection was done into the subacromial space. These misplacements, and especially in the rotator cuff, creates high signal intensity on T2WI that can mimic a rotator cuff tear. Bergman and Fredericson found that the bursal and extrabursal fluid is resolved or decreased 3 days after the injection, so they recommended a 3-day delay after the shoulder injection before performing MRI to prevent misinterpretation of the signal changes. We report here on a case of a false fullthickness tear of the supraspinatus tendon on MRI one month after subacromial injection, and the supraspinatus tendon turned out to be intact on the follow up ultrasonography and arthroscopic examination

  13. Viscous-elastic dynamics of power-law fluids within an elastic cylinder

    Science.gov (United States)

    Boyko, Evgeniy; Bercovici, Moran; Gat, Amir D.

    2017-07-01

    In a wide range of applications, microfluidic channels are implemented in soft substrates. In such configurations, where fluidic inertia and compressibility are negligible, the propagation of fluids in channels is governed by a balance between fluid viscosity and elasticity of the surrounding solid. The viscous-elastic interactions between elastic substrates and non-Newtonian fluids are particularly of interest due to the dependence of viscosity on the state of the system. In this work, we study the fluid-structure interaction dynamics between an incompressible non-Newtonian fluid and a slender linearly elastic cylinder under the creeping flow regime. Considering power-law fluids and applying the thin shell approximation for the elastic cylinder, we obtain a nonhomogeneous p-Laplacian equation governing the viscous-elastic dynamics. We present exact solutions for the pressure and deformation fields for various initial and boundary conditions for both shear-thinning and shear-thickening fluids. We show that in contrast to Stokes' problem where a compactly supported front is obtained for shear-thickening fluids, here the role of viscosity is inversed and such fronts are obtained for shear-thinning fluids. Furthermore, we demonstrate that for the case of a step in inlet pressure, the propagation rate of the front has a tn/n +1 dependence on time (t ), suggesting the ability to indirectly measure the power-law index (n ) of shear-thinning liquids through measurements of elastic deformation.

  14. Aerodynamic reconfiguration and multicriterial optimization of centrifugal compressors – a case study

    Directory of Open Access Journals (Sweden)

    Valeriu DRAGAN

    2014-12-01

    Full Text Available This paper continues the recent research of the author, with application to 3D computational fluid dynamics multicriterial optimization of turbomachinery parts. Computational Fluid Dynamics has been an ubicuous tool for compressor design for decades, helping the designers to test the aerodynamic parameters of their machines with great accuracy. Due to advances of multigrid methods and the improved robustness of structured solvers, CFD can nowadays be part of an optimization loop with artificial neural networks or evolutive algorithms. This paper presents a case study of an air centrifugal compressor rotor optimized using Numeca's Design 3D CFD suite. The turbulence model used for the database generation and the optimization stage is Spalart Allmaras. Results indicate a fairly quick convergence time per individual as well as a good convergence of the artificial neural network optimizer.

  15. CASE STUDY CRITIQUE; UPPER CLINCH CASE STUDY

    Science.gov (United States)

    Case study critique: Upper Clinch case study (from Research on Methods for Integrating Ecological Economics and Ecological Risk Assessment: A Trade-off Weighted Index Approach to Integrating Economics and Ecological Risk Assessment). This critique answers the questions: 1) does ...

  16. Near Wellbore Hydraulic Fracture Propagation from Perforations in Tight Rocks: The Roles of Fracturing Fluid Viscosity and Injection Rate

    Directory of Open Access Journals (Sweden)

    Seyed Hassan Fallahzadeh

    2017-03-01

    Full Text Available Hydraulic fracture initiation and near wellbore propagation is governed by complex failure mechanisms, especially in cased perforated wellbores. Various parameters affect such mechanisms, including fracturing fluid viscosity and injection rate. In this study, three different fracturing fluids with viscosities ranging from 20 to 600 Pa.s were used to investigate the effects of varying fracturing fluid viscosities and fluid injection rates on the fracturing mechanisms. Hydraulic fracturing tests were conducted in cased perforated boreholes made in tight 150 mm synthetic cubic samples. A true tri-axial stress cell was used to simulate real far field stress conditions. In addition, dimensional analyses were performed to correspond the results of lab experiments to field-scale operations. The results indicated that by increasing the fracturing fluid viscosity and injection rate, the fracturing energy increased, and consequently, higher fracturing pressures were observed. However, when the fracturing energy was transferred to a borehole at a faster rate, the fracture initiation angle also increased. This resulted in more curved fracture planes. Accordingly, a new parameter, called fracturing power, was introduced to relate fracture geometry to fluid viscosity and injection rate. Furthermore, it was observed that the presence of casing in the wellbore impacted the stress distribution around the casing in such a way that the fracture propagation deviated from the wellbore vicinity.

  17. A parametric study of a solar calcinator using computational fluid dynamics

    International Nuclear Information System (INIS)

    Fidaros, D.K.; Baxevanou, C.A.; Vlachos, N.S.

    2007-01-01

    In this work a horizontal rotating solar calcinator is studied numerically using computational fluid dynamics. The specific solar reactor is a 10 kW model designed and used for efficiency studies. The numerical model is based on the solution of the Navier-Stokes equations for the gas flow, and on Lagrangean dynamics for the discrete particles. All necessary mathematical models were developed and incorporated into a computational fluid dynamics model with the influence of turbulence simulated by a two-equation (RNG k-ε) model. The efficiency of the reactor was calculated for different thermal inputs, feed rates, rotational speeds and particle diameters. The numerically computed degrees of calcination compared well with equivalent experimental results

  18. Falling, flapping, flying, swimming,...: High-Re fluid-solid interactions with vortex shedding

    Science.gov (United States)

    Michelin, Sebastien Honore Roland

    The coupling between the motion of a solid body and the dynamics of the surrounding flow is essential to the understanding of a large number of engineering and physical problems, from the stability of a slender structure exposed to the wind to the locomotion of insects, birds and fishes. Because of the strong coupling on a moving boundary of the equations for the solid and fluid, the simulation of such problems is computationally challenging and expensive. This justifies the development of simplified models for the fluid-solid interactions to study their physical properties and behavior. This dissertation proposes a reduced-order model for the interaction of a sharp-edged solid body with a strongly unsteady high Reynolds number flow. In such a case, viscous forces in the fluid are often negligible compared to the fluid inertia or the pressure forces, and the thin boundary layers separate from the solid at the edges, leading to the shedding of large and persistent vortices in the solid's wake. A general two-dimensional framework is presented based on complex potential flow theory. The formation of the solid's vortical wake is accounted for by the shedding of point vortices with unsteady intensity from the solid's sharp edges, and the fluid-solid problem is reformulated exclusively as a solid-vortex interaction problem. In the case of a rigid solid body, the coupled problem is shown to reduce to a set of non-linear ordinary differential equations. This model is used to study the effect of vortex shedding on the stability of falling objects. The solid-vortex model is then generalized to study the fluttering instability and non-linear flapping dynamics of flexible plates or flags. The uttering instability and resulting flapping motion result from the competing effects of the fluid forcing and of the solid's flexural rigidity and inertia. Finally, the solid-vortex model is applied to the study of the fundamental effect of bending rigidity on the flapping performance of

  19. COUPLED CHEMOTAXIS FLUID MODEL

    KAUST Repository

    LORZ, ALEXANDER

    2010-06-01

    We consider a model system for the collective behavior of oxygen-driven swimming bacteria in an aquatic fluid. In certain parameter regimes, such suspensions of bacteria feature large-scale convection patterns as a result of the hydrodynamic interaction between bacteria. The presented model consist of a parabolicparabolic chemotaxis system for the oxygen concentration and the bacteria density coupled to an incompressible Stokes equation for the fluid driven by a gravitational force of the heavier bacteria. We show local existence of weak solutions in a bounded domain in d, d = 2, 3 with no-flux boundary condition and in 2 in the case of inhomogeneous Dirichlet conditions for the oxygen. © 2010 World Scientific Publishing Company.

  20. Pulmonary Complications of Gastric Fluid and Bile Salts Aspiration, an Experimental Study in Rat

    OpenAIRE

    Samareh Fekri, Mitra; Poursalehi, Hamid Reza; Najafipour, Hamid; Dabiri, Shahriar; Shokoohi, Mostafa; Siahposht Khacheki, Ali; Shahrokhi, Nader; Malekpour Afshar, Reza; Lashkarizadeh, Mohammad Reza

    2013-01-01

    Objective(s): Gastroesophageal Reflux Disease (GERD) is one of the most common digestive disorders that frequently lead to pulmonary complications due to gastric fluid aspiration. In the present experimental study, chronic aspiration of gastric fluid, its components and bile salts in rat lung was performed to find out the main factor(s) causing pulmonary complications of gastric fluid aspiration. Materials and Methods: Forty eight male rats weighted 250-300 g were selected in six groups. Afte...

  1. Normotension, hypertension and body fluid regulation

    DEFF Research Database (Denmark)

    Bie, Peter; Evans, R G

    2017-01-01

    The fraction of hypertensive patients with essential hypertension (EH) is decreasing as the knowledge of mechanisms of secondary hypertension increases, but in most new cases of hypertension the pathophysiology remains unknown. Separate neurocentric and renocentric concepts of aetiology have...... activity are elevated in about 50% of cases; (iii) in EH as in normal conditions, mediators other than arterial blood pressure are the major determinants of renal sodium excretion; (iv) chronic hypertension is always associated with a shift in the pressure-natriuresis curve, but this may...... prevailed without much interaction. In this regard, several questions regarding the relationships between body fluid and blood pressure regulation are pertinent. Are all forms of EH associated with sympathetic overdrive or a shift in the pressure-natriuresis curve? Is body fluid homoeostasis normally driven...

  2. Lunar Fluid Core and Solid-Body Tides

    Science.gov (United States)

    Williams, J. G.; Boggs, D. H.; Ratcliff, J. T.

    2005-01-01

    Variations in rotation and orientation of the Moon are sensitive to solid-body tidal dissipation, dissipation due to relative motion at the fluid-core/solid-mantle boundary, and tidal Love number k2 [1,2]. There is weaker sensitivity to flattening of the core-mantle boundary (CMB) [2-5] and fluid core moment of inertia [1]. Accurate Lunar Laser Ranging (LLR) measurements of the distance from observatories on the Earth to four retroreflector arrays on the Moon are sensitive to lunar rotation and orientation variations and tidal displacements. Past solutions using the LLR data have given results for dissipation due to solid-body tides and fluid core [1] plus Love number [1-5]. Detection of CMB flattening has been improving [3,5] and now seems significant. This strengthens the case for a fluid lunar core.

  3. Estimating the Impact (Energy, Emissions and Economics) of the US Fluid Power Industry

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J [ORNL

    2012-12-01

    The objective of this report is to estimate the impact (energy, emissions and economics) of United Fluid power (hydraulic and pneumatic actuation) is the generation, control, and application of pumped or compressed fluids when this power is used to provide force and motion to mechanisms. This form of mechanical power is an integral part of United States (U.S.) manufacturing and transportation. In 2008, according to the U.S. Census Bureau, sales of fluid power components exceeded $17.7B, sales of systems using fluid power exceeded $226B. As large as the industry is, it has had little fundamental research that could lead to improved efficiency since the late 1960s (prior to the 1970 energy crisis). While there have been some attempts to replace fluid powered components with electric systems, its performance and rugged operating condition limit the impact of simple part replacement. Oak Ridge National Laboratory and the National Fluid Power Association (NFPA) collaborated with 31 industrial partners to collect and consolidate energy specific measurements (consumption, emissions, efficiency) of deployed fluid power systems. The objective of this study was to establish a rudimentary order of magnitude estimate of the energy consumed by fluid powered systems. The analysis conducted in this study shows that fluid powered systems consumed between 2.0 and 2.9 Quadrillion (1015) Btus (Quads) of energy per year; producing between 310 and 380 million metric tons (MMT) of Carbon Dioxide (CO2). In terms of efficiency, the study indicates that, across all industries, fluid power system efficiencies range from less than 9% to as high as 60% (depending upon the application), with an average efficiency of 22%. A review of case studies shows that there are many opportunities to impact energy savings in both the manufacturing and transportation sectors by the development and deployment of energy efficient fluid power components and systems.

  4. Mathematical and numerical analysis of a multi-velocity multi-fluid model for interpenetration of miscible fluids

    International Nuclear Information System (INIS)

    Enaux, C.

    2007-11-01

    The simulation of indirect laser implosion requires an accurate knowledge of the inter-penetration of the laser target materials turned into plasma. This work is devoted to the study of a multi-velocity multi-fluid model recently proposed by Scannapieco and Cheng (SC) to describe the inter-penetration of miscible fluids. In this document, we begin with presenting the SC model in the context of miscible fluids flow modelling. Afterwards, the mathematical analysis of the model is carried out (study of the hyperbolicity, existence of a strictly convex mathematical entropy, asymptotic analysis and diffusion limit). As a conclusion the problem is well set. Then, we focus on the problem of numerical resolution of systems of conservation laws with a relaxation source term, because SC model belongs to this class. The main difficulty of this task is to capture on a coarse grid the asymptotic behaviour of the system when the source term is stiff. The main contribution of this work lies in the proposition of a new technique, allowing us to construct a Lagrangian numerical flux taking into account the presence of the source term. This technique is applied first on the model-problem of a one-dimensional Euler system with friction, and then on the multi-fluid SC model. In both cases, we prove that the new scheme is asymptotic-preserving and entropic under a CFL-like condition. The two-dimensional extension of the scheme is done by using a standard alternate directions method. Some numerical results highlight the contribution of the new flux, compared with a standard Lagrange plus Remap scheme where the source term is processed using an operator splitting. (author)

  5. Pelvic endometriosis with peritoneal fluid reduces pregnancy rates in women undergoing intrauterine insemination.

    Science.gov (United States)

    Wu, Hong-Ming; Tzeng, Chii-Ruey; Chen, Chi-Hung; Chen, Pi-Hua

    2013-12-01

    This study investigated the occurrence of peritoneal fluid in women undergoing intrauterine insemination (IUI) and its correlation with the stage of pelvic endometriosis and its influence on pregnancy outcomes. A retrospective case-control design was used to recruit 272 infertile women with pelvic endometriosis. The treatment protocol consisted of controlled ovarian hyperstimulation with downregulation and gonadotropin for IUI treatment following ultrasound and laparoscopic intervention. The amount and color of the peritoneal fluid were determined during laparoscopy. The mean amount of peritoneal fluid with pelvic endometriosis that was detected using transvaginal ultrasound was ~ 15.1 mL. Women whose cycles contained more peritoneal fluid had significantly lower pregnancy rates (17.2% and 31.3%, respectively). The total clinical pregnancy rate was not significantly different between the two groups with reddish and yellowish peritoneal fluid who had pelvic endometriosis. Pelvic endometriosis and peritoneal fluid, detected through vaginal ultrasound, have negative effects on the pregnancy outcome of IUI treatment. Copyright © 2013. Published by Elsevier B.V.

  6. Driving under the influence of drugs -- evaluation of analytical data of drugs in oral fluid, serum and urine, and correlation with impairment symptoms.

    Science.gov (United States)

    Toennes, Stefan W; Kauert, Gerold F; Steinmeyer, Stefan; Moeller, Manfred R

    2005-09-10

    A study was performed to acquire urine, serum and oral fluid samples in cases of suspected driving under the influence of drugs of abuse. Oral fluid was collected using a novel sampling/testing device (Dräger DrugTest System). The aim of the study was to evaluate oral fluid and urine as a predictor of blood samples positive for drugs and impairment symptoms. Analysis for cannabinoids, amphetamine and its derivatives, opiates and cocaine was performed in urine using the Mahsan Kombi/DOA4-test, in serum using immunoassay and gas chromatography-mass spectrometry (GC-MS) confirmation and in oral fluid by GC-MS. Police and medical officer observations of impairment symptoms were rated and evaluated using a threshold value for the classification of driving inability. Accuracy in correlating drug detection in oral fluid and serum were >90% for all substances and also >90% in urine and serum except for THC (71.0%). Of the cases with oral fluid positive for any drug 97.1% of corresponding serum samples were also positive for at least one drug; of drug-positive urine samples this were only 82.4%. In 119 of 146 cases, impairment symptoms above threshold were observed (81.5%). Of the cases with drugs detected in serum, 19.1% appeared not impaired which were the same with drug-positive oral fluid while more persons with drug-positive urine samples appeared uninfluenced (32.7%). The data demonstrate that oral fluid is superior to urine in correlating with serum analytical data and impairment symptoms of drivers under the influence of drugs of abuse.

  7. Does Cigarette Smoking Affect Seminal Fluid Parameters? A Comparative Study

    Directory of Open Access Journals (Sweden)

    Zakarya Bani Meri

    2013-01-01

    Full Text Available Objective: To study the effect of cigarette smoking on seminal fluid parameters, namely; volume, sperm concentration, and motility, as well as morphology, leukocyte infiltration, among males complaining of infertility.Methods: Between August 2010 and July 2011, seminal fluid analysis was done for 1438 males who are partners of couples who visited the infertility clinic at Prince Rashid Ben Al Hassan Hospital (PRH for infertility. The men who fit the inclusion criteria (n=960 were classified into two groups: group a (non-smokers; n=564 and group B (smokers; n=396, which represents 41.25% of the study group. Seminal fluid was collected using masturbation after 3-5 days of abstinence then analyzed for volume, sperm count, sperm concentration, motility and morphology. In order to analyze whether the number of cigarettes smoked per day has an effect on the spermatogram; the smoking men were divided into two subgroups: the heavy smokers (n=266 and non-heavy smokers (n=130.Results: A total of 960 adult males were enrolled. Their age ranged between 21 and 76 years, 564 were non-smokers with mean age of 36. 45±6.27 (Mean±SD. Three-hundred-and-ninety-six were smokers with a mean age of 34.35±4.25 (Mean±SD. There was a significant effect of smoking on the motility of sperms and the ratios of abnormality (p<0.005. Concentration appeared not to be affected by smoking. Furthermore, the group of heavy smokers were found to have lower sperm concentrations and a higher percentage of abnormal sperms compared to the non-heavy smokers.Conclusion: Cigarette smoking has a deleterious effect on some of the seminal fluid parameters (motility, morphology and leukocyte count which in turn may result in male subfertility.

  8. Fluid mechanics a geometrical point of view

    CERN Document Server

    Rajeev, S G

    2018-01-01

    Fluid Mechanics: A Geometrical Point of View emphasizes general principles of physics illustrated by simple examples in fluid mechanics. Advanced mathematics (e.g., Riemannian geometry and Lie groups) commonly used in other parts of theoretical physics (e.g. General Relativity or High Energy Physics) are explained and applied to fluid mechanics. This follows on from the author's book Advanced Mechanics (Oxford University Press, 2013). After introducing the fundamental equations (Euler and Navier-Stokes), the book provides particular cases: ideal and viscous flows, shocks, boundary layers, instabilities, and transients. A restrained look at integrable systems (KdV) leads into a formulation of an ideal fluid as a hamiltonian system. Arnold's deep idea, that the instability of a fluid can be understood using the curvature of the diffeomorphism group, will be explained. Leray's work on regularity of Navier-Stokes solutions, and the modern developments arising from it, will be explained in language for physicists...

  9. Improving fluid registration through white matter segmentation in a twin study design

    Science.gov (United States)

    Chou, Yi-Yu; Lepore, Natasha; Brun, Caroline; Barysheva, Marina; McMahon, Katie; de Zubicaray, Greig I.; Wright, Margaret J.; Toga, Arthur W.; Thompson, Paul M.

    2010-03-01

    Robust and automatic non-rigid registration depends on many parameters that have not yet been systematically explored. Here we determined how tissue classification influences non-linear fluid registration of brain MRI. Twin data is ideal for studying this question, as volumetric correlations between corresponding brain regions that are under genetic control should be higher in monozygotic twins (MZ) who share 100% of their genes when compared to dizygotic twins (DZ) who share half their genes on average. When these substructure volumes are quantified using tensor-based morphometry, improved registration can be defined based on which method gives higher MZ twin correlations when compared to DZs, as registration errors tend to deplete these correlations. In a study of 92 subjects, higher effect sizes were found in cumulative distribution functions derived from statistical maps when performing tissue classification before fluid registration, versus fluidly registering the raw images. This gives empirical evidence in favor of pre-segmenting images for tensor-based morphometry.

  10. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    Science.gov (United States)

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  11. Pleural sarcoidosis diagnosed on the basis of an increased CD4/CD8 lymphocyte ratio in pleural effusion fluid: a case report.

    Science.gov (United States)

    Kumagai, Toru; Tomita, Yasuhiko; Inoue, Takako; Uchida, Junji; Nishino, Kazumi; Imamura, Fumio

    2015-08-14

    Pleural effusion induced by sarcoidosis is rare, and pleural sarcoidosis is often diagnosed by thoracoscopic surgery. The diagnosis of pleural sarcoidosis using thoracentesis may be less invasive when sarcoidosis is already diagnosed histologically in more than one organ specimen. Here we report the case of a 64-year-old woman with pleural sarcoidosis diagnosed on the basis of an increased CD4/CD8 lymphocyte ratio in pleural effusion fluid obtained by thoracentesis. This case report is important because it highlights the usefulness of the CD4/CD8 lymphocyte ratio in pleural effusion as an indicator of pleural involvement of sarcoidosis. A 64-year-old Japanese woman visited our hospital with an initial symptom of dyspnea on exertion for a period of 4 months. Chest computed tomography showed bilateral hilar and multiple mediastinal lymphadenopathy, multiple small nodular shadows in her bilateral lungs, small nodular shadows along the interlobar pleura, and bilateral pleural effusion. Her serum angiotensin-converting enzyme and soluble interleukin-2 receptor levels were elevated. Histological analysis of a resected subcutaneous nodule, and biopsy specimens from a right mediastinal lymph node and from her right lung revealed non-caseous epithelioid granulomas. Her bronchoalveolar lavage fluid exhibited a predominance of lymphocytes together with an increase in the CD4/CD8 lymphocyte ratio. The lymphocytic predominance and the increased CD4/CD8 lymphocyte ratio were also detected in the right-sided pleural effusion fluid obtained by thoracentesis. We diagnosed sarcoidosis with pleural involvement. Because pleural effusion did not resolve spontaneously and her symptom of dyspnea on exertion worsened, corticosteroid therapy was initiated, which ameliorated the sarcoidosis and the pleuritis. Analysis of the CD4/CD8 lymphocyte ratio in pleural effusion fluid obtained by thoracentesis may be helpful for the diagnosis of pleural sarcoidosis when the diagnosis is already made

  12. Recording fluid currents by holography

    Science.gov (United States)

    Heflinger, L. O.; Wuerker, R. F.

    1980-01-01

    Convection in fluids can be studied with aid of holographic apparatus that reveals three-dimensional motion of liquid. Apparatus eliminates images of fixed particles such as dust on windows and lenses, which might mask behavior of moving fluid particles. Holographic apparatus was developed for experiments on fluid convection cells under zero gravity. Principle is adaptable to study of fluid processes-for example, electrochemical plating and combustion in automotive engines.

  13. Numerical simulation of a nonlinear coupled fluid-structure problem. Application to the design of naval nuclear propulsion structures; Modelisation et simulation numerique d'un probleme couple fluide/structure non lineaire: application au dimensionnement de structures nucleaires de propulsion navale

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, J.F

    2004-11-15

    The present work deals with the numerical simulation of a coupled fluid/structure problem with fluid free surface. A generic coupled fluid/structure system is defined, on which a linear problem (modal analysis) and a non-linear problem (temporal analysis) are stated. In the linear case, a strong coupled method is used. It is based on a finite element approach of the structure problem and a finite or a boundary element approach of the fluid problem. The coupled problem is formulated in terms of pressure and displacement, leading to a non-symmetric problem which is solved with an appropriate algorithm. In the non-linear case, the structure problem is described with non-linear equations of motion, whereas the fluid problem is modeled with the Stokes equations. The numerical resolution of the coupled problem is based on a weak coupling procedure. The fluid problem is solved with a finite volume technique, using a moving mesh technique to adjust the structure motion, a VOF method for the description of the free surface and the PISO algorithm for the time integration. The structure problem is solved with a finite element technique, using an explicit/implicit time integration algorithm. A procedure is developed in order to handle the coupling in space (fluid forces and structure displacement exchanges between fluid and structure mesh, fluid re-meshing) and in time (staggered explicit algorithm, dynamic filtering of numerical oscillations). The non linear coupled problem is solved using a CFD code, whose use for FSI problem is validated with a benchmark presented in this work. A comparison is proposed between numerical results and analytical solution for two elementary fluid problems. The validation process can be applied for any CFD numerical code. A numerical study is then proposed on the generic coupled case in order to describe the fluid/structure interaction phenomenon (added mass, displaced mass, mode coupling, influence of structural non-linearity). An industrial

  14. Transverse vibration of pipe conveying fluid made of functionally graded materials using a symplectic method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhong-Min, E-mail: wangzhongm@xaut.edu.cn; Liu, Yan-Zhuang

    2016-03-15

    Highlights: • We investigate the transverse vibration of FGM pipe conveying fluid. • The FGM pipe conveying fluid can be classified into two cases. • The variations between the frequency and the power law exponent are obtained. • “Case 1” is relatively more reasonable than “case 2”. - Abstract: Problems related to the transverse vibration of pipe conveying fluid made of functionally graded material (FGM) are addressed. Based on inside and outside surface material compositions of the pipe, FGM pipe conveying fluid can be classified into two cases. It is hypothesized that the physical parameters of the material along the direction of the pipe wall thickness change in the simple power law. A differential equation of motion expressed in non-dimensional quantities is derived by using Hamilton's principle for systems of changing mass. Using the assuming modal method, the pipe deflection function is expanded into a series, in which each term is expressed to admissible function multiplied by generalized coordinate. Then, the differential equation of motion is discretized into the two order differential equations expressed in the generalized coordinates. Based on symplectic elastic theory and the introduction of dual system and dual variable, Hamilton's dual equations are derived, and the original problem is reduced to eigenvalue and eigenvector problem in the symplectic space. Finally, a symplectic method is employed to analyze the vibration and stability of FGM pipe conveying fluid. For a clamped–clamped FGM pipe conveying fluid in “case 1” and “case 2”, the dimensionless critical flow velocity for first-mode divergence and the critical coupled-mode flutter flow velocity are obtained, and the variations between the real part and imaginary part of dimensionless complex frequency and fluid velocity, mass ratio and the power law exponent (or graded index, volume fraction) for FGM pipe conveying fluid are analyzed.

  15. Transverse vibration of pipe conveying fluid made of functionally graded materials using a symplectic method

    International Nuclear Information System (INIS)

    Wang, Zhong-Min; Liu, Yan-Zhuang

    2016-01-01

    Highlights: • We investigate the transverse vibration of FGM pipe conveying fluid. • The FGM pipe conveying fluid can be classified into two cases. • The variations between the frequency and the power law exponent are obtained. • “Case 1” is relatively more reasonable than “case 2”. - Abstract: Problems related to the transverse vibration of pipe conveying fluid made of functionally graded material (FGM) are addressed. Based on inside and outside surface material compositions of the pipe, FGM pipe conveying fluid can be classified into two cases. It is hypothesized that the physical parameters of the material along the direction of the pipe wall thickness change in the simple power law. A differential equation of motion expressed in non-dimensional quantities is derived by using Hamilton's principle for systems of changing mass. Using the assuming modal method, the pipe deflection function is expanded into a series, in which each term is expressed to admissible function multiplied by generalized coordinate. Then, the differential equation of motion is discretized into the two order differential equations expressed in the generalized coordinates. Based on symplectic elastic theory and the introduction of dual system and dual variable, Hamilton's dual equations are derived, and the original problem is reduced to eigenvalue and eigenvector problem in the symplectic space. Finally, a symplectic method is employed to analyze the vibration and stability of FGM pipe conveying fluid. For a clamped–clamped FGM pipe conveying fluid in “case 1” and “case 2”, the dimensionless critical flow velocity for first-mode divergence and the critical coupled-mode flutter flow velocity are obtained, and the variations between the real part and imaginary part of dimensionless complex frequency and fluid velocity, mass ratio and the power law exponent (or graded index, volume fraction) for FGM pipe conveying fluid are analyzed.

  16. A new 3D immersed boundary method for non-Newtonian fluid-structure-interaction with application

    Science.gov (United States)

    Zhu, Luoding

    2017-11-01

    Motivated by fluid-structure-interaction (FSI) phenomena in life sciences (e.g., motions of sperm and cytoskeleton in complex fluids), we introduce a new immersed boundary method for FSI problems involving non-Newtonian fluids in three dimensions. The non-Newtonian fluids are modelled by the FENE-P model (including the Oldroyd-B model as an especial case) and numerically solved by a lattice Boltzmann scheme (the D3Q7 model). The fluid flow is modelled by the lattice Boltzmann equations and numerically solved by the D3Q19 model. The deformable structure and the fluid-structure-interaction are handled by the immersed boundary method. As an application, we study a FSI toy problem - interaction of an elastic plate (flapped at its leading edge and restricted nowhere else) with a non-Newtonian fluid in a 3D flow. Thanks to the support of NSF-DMS support under research Grant 1522554.

  17. Interfacial instabilities in vibrated fluids

    Science.gov (United States)

    Porter, Jeff; Laverón-Simavilla, Ana; Tinao Perez-Miravete, Ignacio; Fernandez Fraile, Jose Javier

    2016-07-01

    Vibrations induce a range of different interfacial phenomena in fluid systems depending on the frequency and orientation of the forcing. With gravity, (large) interfaces are approximately flat and there is a qualitative difference between vertical and horizontal forcing. Sufficient vertical forcing produces subharmonic standing waves (Faraday waves) that extend over the whole interface. Horizontal forcing can excite both localized and extended interfacial phenomena. The vibrating solid boundaries act as wavemakers to excite traveling waves (or sloshing modes at low frequencies) but they also drive evanescent bulk modes whose oscillatory pressure gradient can parametrically excite subharmonic surface waves like cross-waves. Depending on the magnitude of the damping and the aspect ratio of the container, these locally generated surfaces waves may interact in the interior resulting in temporal modulation and other complex dynamics. In the case where the interface separates two fluids of different density in, for example, a rectangular container, the mass transfer due to vertical motion near the endwalls requires a counterflow in the interior region that can lead to a Kelvin-Helmholtz type instability and a ``frozen wave" pattern. In microgravity, the dominance of surface forces favors non-flat equilibrium configurations and the distinction between vertical and horizontal applied forcing can be lost. Hysteresis and multiplicity of solutions are more common, especially in non-wetting systems where disconnected (partial) volumes of fluid can be established. Furthermore, the vibrational field contributes a dynamic pressure term that competes with surface tension to select the (time averaged) shape of the surface. These new (quasi-static) surface configurations, known as vibroequilibria, can differ substantially from the hydrostatic state. There is a tendency for the interface to orient perpendicular to the vibrational axis and, in some cases, a bulge or cavity is induced

  18. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    Science.gov (United States)

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  19. Isotopic transit in the cerebrospinal fluid value of In111 and results of its use in the study of malformations of the occipito-cervical region

    International Nuclear Information System (INIS)

    Moretti, J.L.; Comoy, J.; Robert, G.; Mathieu, E.; Galle, P.; Caron, J.P.

    1975-01-01

    In-111 DTPA has been used in more than 200 studies of isotopic transit in the cerebrospinal fluid since the beginning of 1973. The results obtained with this isotope in 15 cases of malformation of the occipito-cervical region, scanned after lumbar and intra-ventricular injection, represent an example of its usefulness [fr

  20. Fluid structure interaction in LMFBR cores modelling by an homogenization method

    International Nuclear Information System (INIS)

    Brochard, D.

    1988-01-01

    The upper plenum of the internals of PWR, the steam generator bundle, the nuclear reactor core, may be schematically represented by a beam bundle immersed in a fluid. The dynamical study of such a system needs to take into account fluid structure interaction. A refined model at the scale of the tubes can be used but leads to a very difficult problem to solve even on the largest computers. The homogenization method allows to have an approximation of the fluid structure interaction for the global behaviour of the bundle. It consists of replacing the heterogeneous physical medium (tubes and fluid) by an equivalent homogeneous medium whose characteristics are determined from the resolution of a set of problems on the elementary cell. The aim of this paper is to present the main steps of the determination of this equivalent medium in the case of small displacements (acoustic behaviour of the fluid). Then an application to LMFBR core geometry has been realised, which shows the lowering effect on eigenfrequencies due to the fluid. Some comparisons with test results will be presented. 6 refs, 7 figs, 2 tabs

  1. Prenatal sex determination by radioimmunoassay of testosterone with and without chromatography of the amniotic fluid

    International Nuclear Information System (INIS)

    Distler, W.; Boniver-Ollmann, U.; Tigges, J.; Terinde, R.; Claussen, U.

    1979-01-01

    Amniotic fluid testosterone measured by radioimmunoassay (RIA) without chromatography (immunoreactive testosterone) seems not to be a definitive test for prenatal sex determination in all cases. In this study testosterone (T) levels measured by RIA with chromatography of the amniotic fluid samples were compared with immunoreactive testosterone (iT) values, to determine the predictive accuracy of the two methods. In 111 amniotic fluid samples between 15 and 19 weeks of gestation iT and T were measured parallelly. There are significant differences between iT- and T-means of both sexes (p [de

  2. Prenatal diagnosis of congenital toxoplasmosis: comparative value of fetal blood and amniotic fluid using serological techniques and cultures.

    Science.gov (United States)

    Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P

    1997-09-01

    The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.

  3. Modeling interfacial area transport in multi-fluid systems

    Energy Technology Data Exchange (ETDEWEB)

    Yarbro, Stephen Lee [Univ. of California, Berkeley, CA (United States)

    1996-11-01

    Many typical chemical engineering operations are multi-fluid systems. They are carried out in distillation columns (vapor/liquid), liquid-liquid contactors (liquid/liquid) and other similar devices. An important parameter is interfacial area concentration, which determines the rate of interfluid heat, mass and momentum transfer and ultimately, the overall performance of the equipment. In many cases, the models for determining interfacial area concentration are empirical and can only describe the cases for which there is experimental data. In an effort to understand multiphase reactors and the mixing process better, a multi-fluid model has been developed as part of a research effort to calculate interfacial area transport in several different types of in-line static mixers. For this work, the ensemble-averaged property conservation equations have been derived for each fluid and for the mixture. These equations were then combined to derive a transport equation for the interfacial area concentration. The final, one-dimensional model was compared to interfacial area concentration data from two sizes of Kenics in-line mixer, two sizes of concurrent jet and a Tee mixer. In all cases, the calculated and experimental data compared well with the highest scatter being with the Tee mixer comparison.

  4. Effect of lidocaine 2% on bacterial culture of bronchial fluid

    International Nuclear Information System (INIS)

    Samet, M.; Meybodi, F.A.A.; Mokarianpour, T.; Fallah, T.; Mongabadi, F.D.; Ayatollahi, J.; Shahcherghi, S.H.; Yazdi, M.H.A

    2017-01-01

    Objective:To evaluate the action of 2% lidocaine on the culture results of bronchial fluid in patients suspected of having lower respiratory tract infections. Study Design:Cross-sectional analytical study. Place and Duration of Study:Shahid Sadoughi Hospital, Yazd, Iran, from November 2014 to November 2015. Methodology:Patients suspected of lower respiratory tract infections referred to bronchoscopy unit of the Hospital were included. Those with incomplete questionnaire and bronchoscopy contraindication were excluded. Bronchial fluid was aspirated before and after local application of 2% lidocaine and cultured, according to the suspected clinical diagnosis. Finally, statistical analysis was performed using SPSS software, version 17.0. For statistical comparisons, McNemar's test was used. Level of significance was kept at p <0.05. Results:The mean age of the study population was 51.83 +-15.93 with a range of 25 - 80 years. Out of 130 patients, 60 patients had positive culture results. Nineteen (31.7%) cases had positive culture for tuberculosis and 41 (63.3%) cases had positive results for other bacteria before intervention that did not change after using 2% lidocaine (p=1). In 70 (53.84%) cases, results were negative before and after use of 2% lidocaine. Conclusion:No significant difference was found between culture results before and after the use of lidocaine. Therefore, lidocaine can be used during bronchoscopy to increase patient tolerance. (author)

  5. The Impact of Solid Surface Features on Fluid-Fluid Interface Configuration

    Science.gov (United States)

    Araujo, J. B.; Brusseau, M. L. L.

    2017-12-01

    Pore-scale fluid processes in geological media are critical for a broad range of applications such as radioactive waste disposal, carbon sequestration, soil moisture distribution, subsurface pollution, land stability, and oil and gas recovery. The continued improvement of high-resolution image acquisition and processing have provided a means to test the usefulness of theoretical models developed to simulate pore-scale fluid processes, through the direct quantification of interfaces. High-resolution synchrotron X-ray microtomography is used in combination with advanced visualization tools to characterize fluid distributions in natural geologic media. The studies revealed the presence of fluid-fluid interface associated with macroscopic features on the surfaces of the solids such as pits and crevices. These features and respective fluid interfaces, which are not included in current theoretical or computational models, may have a significant impact on accurate simulation and understanding of multi-phase flow, energy, heat and mass transfer processes.

  6. Simultaneous measurement of particle and fluid velocities in particle-laden flows

    International Nuclear Information System (INIS)

    Jin, D. X.; Lee, D. Y.

    2009-01-01

    For the velocity measurement in a particle-laden fluid flow, the fluid velocity and the inherently dispersed particle velocity can be analyzed by using PIV and PTV, respectively. Since the PIV result statistically represents the average displacement of all the particles in a PIV image, it is inevitable that the PIV result includes the influence of the dispersed particles' displacement if a single CCD camera is used to simultaneously measure the fluid velocity and the dispersed particle velocity. The influence of dispersed particles should be excluded before the PIV analysis in order to evaluate the fluid velocity accurately. In this study, the optimum replacement brightness of dispersed particles to minimize the false influence of dispersed particles on the PIV analysis was theoretically derived. Simulation results show that the modification of dispersed particle brightness can significantly reduce the PIV error caused by the dispersed particles. This modification method was also verified in the analysis of an actual experimental case of the particle-laden fluid flow in a triangular grooved channel

  7. Investigations of Cutting Fluid Performance Using Different Machining Operations

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Belluco, Walter

    2002-01-01

    An analysis of cutting fluid performance in dif-ferent metal cutting operations is presented based on performance criteria, work material and fluid type. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping operations, with respect to tool life, cutting forces and prod...... will get the same performance ranking for different metalworking fluids no matter what machining test is used, when the fluids are of the same type. Results show that this is mostly true for the water-based fluids on austenitic stainless steel while ranking did change depending on the test with straight......-gated. In the case of austenitic stainless steel as the workpiece material, results using the different operations under different cutting conditions show that the performance of vegetable oil based prod-ucts is superior or equal to that of mineral oil based products. The hypothesis was investigated that one...

  8. A Blended Learning Approach to Teach Fluid Mechanics in Engineering

    Science.gov (United States)

    Rahman, Ataur

    2017-01-01

    This paper presents a case study on the teaching and learning of fluid mechanics at the University of Western Sydney (UWS), Australia, by applying a blended learning approach (BLA). In the adopted BLA, various flexible learning materials have been made available to the students such as online recorded lectures, online recorded tutorials, hand…

  9. Comparative Study of Pregnancy Outcome in Premature Rupture of Membranes With Amniotic Fluid Indices of less and more than 5

    Directory of Open Access Journals (Sweden)

    F Tavassoli

    2010-03-01

    Full Text Available Introduction: Preterm premature rupture of the membranes (PPROM is one of the most important causes of perinatal morbidity and mortality. The aim of this study was to evaluate pregnancy outcome in preterm premature rupture of the membranes with amniotic fluid index less than 5 and more than 5. Methods: This prospective study was performed on 137 pregnant women with gestational age of 28-34 weeks with PPROM from Oct 2006 to Oct 2008. The patients were divided in two groups according to amniotic fluid index: AFI<5 (77 cases, AFI≥5 (60 cases. Chi-square test was used for qualitative variables, while T-student test was used for quantitative test. Results: Both groups were similar with respect to number of pregnancies, gestational age at rupture of the membranes and birth weight. In the group with AFI<5, applied latency was significantly shorter (PV=0.049, rate of cesarean section was higher due to fetal distress (PV=0.008, neonatal Apgar score in first minute was lower during the first week (PV=0.0127 and the rate of neonatal death was higher (PV=0.045 during the first week. Conclusion: An AFI<5 cm after PPROM is associated with earlier delivery, higher rate of cesarean due to fetal distress, higher rate of neonatal death, and lower neonatal Apgar score in first minute during the first week

  10. A coupled reaction and transport model for assessing the injection, migration and fate of waste fluids

    International Nuclear Information System (INIS)

    Liu, X.; Ortoleva, P.

    1996-01-01

    The use of reaction-transport modeling for reservoir assessment and management in the context of deep well waste injection is evaluated. The study is based on CIRF.A (Chemical Interaction of Rock and Fluid), a fully coupled multiphase flow, contaminant transport, and fluid and mineral reaction model. Although SWIFT (Sandia Waste-Isolation Flow and Transport Model) is often the numerical model of choice, it can not account for chemical reactions involving rock, wastes, and formation fluids and their effects on contaminant transport, rock permeability and porosity, and the integrity of the reservoir and confining units. CIRF.A can simulate all these processes. Two field cases of waste injection were simulated by CIRF.A. Both observation data and simulation results show mineral precipitation in one case and rock dissolution in another case. Precipitation and dissolution change rock porosity and permeability, and hence the pattern of fluid migration. The model is shown to be invaluable in analyzing near borehole and reservoir-scale effects during waste injection and predicting the 10,000 year fate of the waste plume. The benefits of using underpressured compartments as waste repositories were also demonstrated by CIRF.A simulations

  11. Theoretical study on flow-induced vibration of a cylindrical weir due to fluid discharge

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Ito, Tomohiro; Hirota, Kazuo; Kodama, Tetsuhiko

    1994-01-01

    In a FBR, the inside of the reactor vessel is cooled by liquid sodium. Liquid sodium is supplied to the upper plenum from its bottom and discharges over the top of the cylindrical weir down to the lower plenum. The weir is so thin in order to decrease the thermal stress on it that the fluid--structure interaction becomes predominant. A fluidelastic vibration of the weir due to fluid discharge was discovered in a French FBR. In this study, a theoretical model was developed on the ''fluid--elastic mode'' instability of a cylindrical weir due to fluid discharge from the upper plenum to the lower plenum. In the analysis, the fluctuation of both the discharge flow rate over a weir due to the vibration of the cylindrical shell and the pressure in the lower plenum due to fluid discharge were formulated. Instability criteria was derived from the added damping ratio due to fluid discharge using modal analysis. The natural modes and modal mass of the weir were obtained by the analysis using the FEM code taking the fluid - structure interaction into consideration. The theoretical instability range in terms of the fall height and the flow rate is compared with the experimental results. The theoretical values showed a good agreement with the experimental ones

  12. [Detection of metals and metalloids in the lavage fluid of whole-lung lavage of the cases of pneumoconiosis].

    Science.gov (United States)

    Wen, K; Ding, C G; Chen, G; Ma, G X; Wang, H Q

    2017-11-20

    Objective: To detect of the components and concentration of the metals and metalloids in the lavage fluid of whole-lung lavage (WLL) of the cases of pneumoconiosis, and analyze the characteristics, and explore the method to sample and process the samples of bronchoalveolar lavage fluid (BAL) . Methods: The samples of urine and serum of three cases of pneumoconiosis were collected before WLL, and the samples of BAL were collected during the WLL from the left and right lungs according to the sequence of four pressured gas flow and five negative pressure drainage. Each of 10ml original samples of WLL was collected firstly, and the left was centrifuged to acquire all the sediment samples and each of 10 ml samples from the centrifuge clear liquids, The components and concentration of the metals and metalloids in the samples were measured by Inductively Coupled Plasma mass spectrometer (ICP-MS) . Results: The average volume of BAL from unilat-eral lung for 3 patients was 10 758.3±1518 ml, and the average recovery rate was 89.7%. The average dry weight of sediment samples of BAL of three cases of pneumoconiosis was 0.292 gram with the right lung sam-ples slightly higher than the left lung samples. The detectable elements from the samples included Barium (Ba) , Strontium (Sr) , Calcium (Ca) , Magnesium (Mg) , Manganum (Mn) , Ferrum (Fe) , Cuprum (Cu) , Zinc (Zn) , Kalium (K) , Natrium (Na) , Selenium (Se) , Silicon (Si) and Uranium (U) . Each of concentration dis-tributions of these elements were not normal. Except for Cuprum, Selenium and Uranium, the concentrations of the other ten elements in the supernatant samples, mixture samples and sediments samples were statistical-ly different with the nonparametric test of Kruskal-Wallis. The concentrations of Natrium, Kalium and Barium in supernatant samples were higher, while the others in precipitation samples were higher. The concentration of elements in the sample from the right lung was slightly higher than that from the

  13. Relativistic Fluid Dynamics Far From Local Equilibrium

    Science.gov (United States)

    Romatschke, Paul

    2018-01-01

    Fluid dynamics is traditionally thought to apply only to systems near local equilibrium. In this case, the effective theory of fluid dynamics can be constructed as a gradient series. Recent applications of resurgence suggest that this gradient series diverges, but can be Borel resummed, giving rise to a hydrodynamic attractor solution which is well defined even for large gradients. Arbitrary initial data quickly approaches this attractor via nonhydrodynamic mode decay. This suggests the existence of a new theory of far-from-equilibrium fluid dynamics. In this Letter, the framework of fluid dynamics far from local equilibrium for a conformal system is introduced, and the hydrodynamic attractor solutions for resummed Baier-Romatschke-Son-Starinets-Stephanov theory, kinetic theory in the relaxation time approximation, and strongly coupled N =4 super Yang-Mills theory are identified for a system undergoing Bjorken flow.

  14. Experimental study on CHF characteristics of water-TiO2 nano-fluids

    International Nuclear Information System (INIS)

    Kim, Hyung Dae; Kim Moo Hwan; Kim, Jeong Bae

    2006-01-01

    CHF characteristics of nano-fluids were investigated with different volumetric concentrations of TiO 2 nanoparticles. Pool boiling experiments indicated that the application of nano-fluids, instead of pure water, as a cooling liquid significantly increased the CHF. SEM (Scanning Electron Microscope) observations subsequent to the pool boiling experiments revealed that nanoparticles were coated on the heating surface during pool boiling of nano-fluids. In order to investigate the roles of nanoparticles in CHF enhancement of nano-fluids, pool boiling experiments were performed using (a) a nanoparticle-coated heater, prepared by pool boiling of nano-fluids, immersed in pure water and (b) a nanoparticle-coated heater immersed in nano-fluids. The results demonstrated two different roles of nanoparticles in CHF enhancement using nano-fluids: the effect of nanoparticles coated on the heater surface and the effect of nanoparticles suspended in nano-fluids

  15. Simplified Aeroelastic Model for Fluid Structure Interaction between Microcantilever Sensors and Fluid Surroundings.

    Directory of Open Access Journals (Sweden)

    Fei Wang

    Full Text Available Fluid-structural coupling occurs when microcantilever sensors vibrate in a fluid. Due to the complexity of the mechanical characteristics of microcantilevers and lack of high-precision microscopic mechanical testing instruments, effective methods for studying the fluid-structural coupling of microcantilevers are lacking, especially for non-rectangular microcantilevers. Here, we report fluid-structure interactions (FSI of the cable-membrane structure via a macroscopic study. The simplified aeroelastic model was introduced into the microscopic field to establish a fluid-structure coupling vibration model for microcantilever sensors. We used the finite element method to solve the coupled FSI system. Based on the simplified aeroelastic model, simulation analysis of the effects of the air environment on the vibration of the commonly used rectangular microcantilever was also performed. The obtained results are consistent with the literature. The proposed model can also be applied to the auxiliary design of rectangular and non-rectangular sensors used in fluid environments.

  16. Development of the tube bundle structure for fluid-structure interaction analysis model

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho; Kim, Jae Yong

    2010-02-01

    Tube bundle structures within a Boiler or heat exchanger are laid the fluid-structure, thermal-structure and fluid-thermal-structure coupled boundary condition. In these complicated boundary conditions, Fluid-structure interaction (FSI) occurs when fluid flow causes deformation of the structure. This deformation, in turn, changes the boundary conditions for the fluid flow. The structural analysis discipline, and then independently analyzed each other. However, the fluid dynamic force effect the behavior of the structure, and the vibration amplitude of the structure to fluid. FSI analysis model was separately created fluid and structure model, and then defined the fsi boundary condition, and simultaneously analyzed in one domain. The analysis results were compared with those of the experimental method for validating the analysis model. Flow-induced vibration test was executed with single rod configuration. The vibration amplitudes of a fuel rod were measured by the laser vibro-meter system in x and y-direction. The analyses results were not closely with the test data, but the trend was very similar with the test result. In fsi coupled analysis case, the turbulent model was very important with the reliability of the accuracy of the analysis model. Therefore, the analysis model will be needed to further study

  17. Experimental and theoretical studies of levitated quantum fluids

    International Nuclear Information System (INIS)

    Schmidt, J.; Halley, J.W.; Giese, C.F.

    1998-01-01

    We describe the opportunities for improved scientific understanding and technical manipulation of cryogenic fields, particularly molecular hydrogen, by the use of carefully designed magnetic field configurations produced with assemblies of permanent magnets. We discuss the levitation of hydrogen in order to perfect technical means for handling this and other cryogenic fluids. The development of the techniques to be explored here provide extraordinary opportunities for improved methods for handling rocket fuels and cryogenic fluids in low gravity environments

  18. Dissolution Dynamic Nuclear Polarization capability study with fluid path

    DEFF Research Database (Denmark)

    Malinowski, Ronja Maja; Lipsø, Hans Kasper Wigh; Lerche, Mathilde Hauge

    2016-01-01

    Signal enhancement by hyperpolarization is a way of overcoming the low sensitivity in magnetic resonance; MRI in particular. One of the most well-known methods, dissolution Dynamic Nuclear Polarization, has been used clinically in cancer patients. One way of ensuring a low bioburden of the hyperp......Signal enhancement by hyperpolarization is a way of overcoming the low sensitivity in magnetic resonance; MRI in particular. One of the most well-known methods, dissolution Dynamic Nuclear Polarization, has been used clinically in cancer patients. One way of ensuring a low bioburden...... of the hyperpolarized product is by use of a closed fluid path that constitutes a barrier to contamination. The fluid path can be filled with the pharmaceuticals, i.e. imaging agent and solvents, in a clean room, and then stored or immediately used at the polarizer. In this study, we present a method of filling...

  19. Study of biological fluids by nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Kriat, M.; Vion-Dury, J.; Confort-Gouny, S.; Sciaky, M.; Cozzone, P.J.

    1991-01-01

    The use of nuclear magnetic resonance (NMR) spectroscopy in the study of biofluids is rapidly developing and might soon constitute a new major medical application of this technique which benefits from technological and methodological progress such as higher magnetic fields, new probe design, solvent suppression sequences and advanced data processing routines. In this overview, the clinical and pharmacological impact of this new approach is examined, with emphasis on the NMR spectroscopy of plasma, cerebrospinal fluid and urine. Applications to pharmacokinetics and toxicology are illustrated. Interestingly, a number of biochemical components of fluids which are not usually assayed by conventional biochemical methods are readily detected by NMR spectroscopy which is clearly a new competitive entrant among the techniques used in clinical biology. Its ease-of-use, cost effectiveness and high informational content might turn it into a major diagnostic tool in the years to come [fr

  20. Modelling dynamic liquid-gas systems: Extensions to the volume-of-fluid solver

    CSIR Research Space (South Africa)

    Heyns, Johan A

    2013-06-01

    Full Text Available This study presents the extension of the volume-of-fluid solver, interFoam, for improved accuracy and efficiency when modelling dynamic liquid-gas systems. Examples of these include the transportation of liquids, such as in the case of fuel carried...

  1. Time Independent Fluids

    Science.gov (United States)

    Collyer, A. A.

    1973-01-01

    Discusses theories underlying Newtonian and non-Newtonian fluids by explaining flow curves exhibited by plastic, shear-thining, and shear-thickening fluids and Bingham plastic materials. Indicates that the exact mechanism governing shear-thickening behaviors is a problem of further study. (CC)

  2. Two-fluid equilibria with flow

    International Nuclear Information System (INIS)

    Steinhauer, L.

    1999-01-01

    The formalism is developed for flowing two-fluid equilibria. The equilibrium system is governed by a pair of second order partial differential equations for the magnetic stream function and the ion stream function plus a Bernoulli-like equation for the density. There are six arbitrary surface function. There are separate characteristic surfaces for each species, which are the guiding-center surfaces. This system is a generalization of the familiar Grad-Shafranov system for a single-fluid equilibrium without flow, which has only one equation and two arbitrary surface functions. In the case of minimum energy equilibria, the six surface functions take on particular forms. (author)

  3. Working Fluids for Increasing Capacities of Heat Pipes

    Science.gov (United States)

    Chao, David F.; Zhang, Nengli

    2004-01-01

    A theoretical and experimental investigation has shown that the capacities of heat pipes can be increased through suitable reformulation of their working fluids. The surface tensions of all of the working fluids heretofore used in heat pipes decrease with temperature. As explained in more detail below, the limits on the performance of a heat pipe are associated with the decrease in the surface tension of the working fluid with temperature, and so one can enhance performance by reformulating the working fluid so that its surface tension increases with temperature. This improvement is applicable to almost any kind of heat pipe in almost any environment. The heat-transfer capacity of a heat pipe in its normal operating-temperature range is subject to a capillary limit and a boiling limit. Both of these limits are associated with the temperature dependence of surface tension of the working fluid. In the case of a traditional working fluid, the decrease in surface tension with temperature causes a body of the liquid phase of the working fluid to move toward a region of lower temperature, thus preventing the desired spreading of the liquid in the heated portion of the heat pipe. As a result, the available capillary-pressure pumping head decreases as the temperature of the evaporator end of the heat pipe increases, and operation becomes unstable. Water has widely been used as a working fluid in heat pipes. Because the surface tension of water decreases with increasing temperature, the heat loads and other aspects of performance of heat pipes that contain water are limited. Dilute aqueous solutions of long-chain alcohols have shown promise as substitutes for water that can offer improved performance, because these solutions exhibit unusual surface-tension characteristics: Experiments have shown that in the cases of an aqueous solution of an alcohol, the molecules of which contain chains of more than four carbon atoms, the surface tension increases with temperature when the

  4. Study of blood flow in several benchmark micro-channels using a two-fluid approach.

    Science.gov (United States)

    Wu, Wei-Tao; Yang, Fang; Antaki, James F; Aubry, Nadine; Massoudi, Mehrdad

    2015-10-01

    It is known that in a vessel whose characteristic dimension (e.g., its diameter) is in the range of 20 to 500 microns, blood behaves as a non-Newtonian fluid, exhibiting complex phenomena, such as shear-thinning, stress relaxation, and also multi-component behaviors, such as the Fahraeus effect, plasma-skimming, etc. For describing these non-Newtonian and multi-component characteristics of blood, using the framework of mixture theory, a two-fluid model is applied, where the plasma is treated as a Newtonian fluid and the red blood cells (RBCs) are treated as shear-thinning fluid. A computational fluid dynamic (CFD) simulation incorporating the constitutive model was implemented using OpenFOAM® in which benchmark problems including a sudden expansion and various driven slots and crevices were studied numerically. The numerical results exhibited good agreement with the experimental observations with respect to both the velocity field and the volume fraction distribution of RBCs.

  5. Study of blood flow in several benchmark micro-channels using a two-fluid approach

    Science.gov (United States)

    Wu, Wei-Tao; Yang, Fang; Antaki, James F.; Aubry, Nadine; Massoudi, Mehrdad

    2015-01-01

    It is known that in a vessel whose characteristic dimension (e.g., its diameter) is in the range of 20 to 500 microns, blood behaves as a non-Newtonian fluid, exhibiting complex phenomena, such as shear-thinning, stress relaxation, and also multi-component behaviors, such as the Fahraeus effect, plasma-skimming, etc. For describing these non-Newtonian and multi-component characteristics of blood, using the framework of mixture theory, a two-fluid model is applied, where the plasma is treated as a Newtonian fluid and the red blood cells (RBCs) are treated as shear-thinning fluid. A computational fluid dynamic (CFD) simulation incorporating the constitutive model was implemented using OpenFOAM® in which benchmark problems including a sudden expansion and various driven slots and crevices were studied numerically. The numerical results exhibited good agreement with the experimental observations with respect to both the velocity field and the volume fraction distribution of RBCs. PMID:26240438

  6. Modelling non-dust fluids in cosmology

    International Nuclear Information System (INIS)

    Christopherson, Adam J.; Hidalgo, Juan Carlos; Malik, Karim A.

    2013-01-01

    Currently, most of the numerical simulations of structure formation use Newtonian gravity. When modelling pressureless dark matter, or 'dust', this approach gives the correct results for scales much smaller than the cosmological horizon, but for scenarios in which the fluid has pressure this is no longer the case. In this article, we present the correspondence of perturbations in Newtonian and cosmological perturbation theory, showing exact mathematical equivalence for pressureless matter, and giving the relativistic corrections for matter with pressure. As an example, we study the case of scalar field dark matter which features non-zero pressure perturbations. We discuss some problems which may arise when evolving the perturbations in this model with Newtonian numerical simulations and with CMB Boltzmann codes

  7. Random Process Theory Approach to Geometric Heterogeneous Surfaces: Effective Fluid-Solid Interaction

    Science.gov (United States)

    Khlyupin, Aleksey; Aslyamov, Timur

    2017-06-01

    Realistic fluid-solid interaction potentials are essential in description of confined fluids especially in the case of geometric heterogeneous surfaces. Correlated random field is considered as a model of random surface with high geometric roughness. We provide the general theory of effective coarse-grained fluid-solid potential by proper averaging of the free energy of fluid molecules which interact with the solid media. This procedure is largely based on the theory of random processes. We apply first passage time probability problem and assume the local Markov properties of random surfaces. General expression of effective fluid-solid potential is obtained. In the case of small surface irregularities analytical approximation for effective potential is proposed. Both amorphous materials with large surface roughness and crystalline solids with several types of fcc lattices are considered. It is shown that the wider the lattice spacing in terms of molecular diameter of the fluid, the more obtained potentials differ from classical ones. A comparison with published Monte-Carlo simulations was discussed. The work provides a promising approach to explore how the random geometric heterogeneity affects on thermodynamic properties of the fluids.

  8. Studying fluid squeeze characteristics for aerostatic journal bearing

    International Nuclear Information System (INIS)

    Abdel-Rahman, Gamal M.

    2008-01-01

    The Reynolds equation for studying fluid squeeze of aerostatic journal bearing is solved numerically by considering the quasi-steady behavior of the air film. The radial displacement can influence the air film thickness modifying the pressure distribution in the journal-bearing gap. Also, the variations in the seal characteristics with eccentricity, time, squeeze number, length-to-diameter and supply pressure are presented. The numerical results for the squeeze load-carrying capacity are given in a non-dimensional form

  9. Unsteady Mixed Convection Boundary Layer from a Circular Cylinder in a Micropolar Fluid

    Directory of Open Access Journals (Sweden)

    Anati Ali

    2010-01-01

    Full Text Available Most industrial fluids such as polymers, liquid crystals, and colloids contain suspensions of rigid particles that undergo rotation. However, the classical Navier-Stokes theory normally associated with Newtonian fluids is inadequate to describe such fluids as it does not take into account the effects of these microstructures. In this paper, the unsteady mixed convection boundary layer flow of a micropolar fluid past an isothermal horizontal circular cylinder is numerically studied, where the unsteadiness is due to an impulsive motion of the free stream. Both the assisting (heated cylinder and opposing cases (cooled cylinder are considered. Thus, both small and large time solutions as well as the occurrence of flow separation, followed by the flow reversal are studied. The flow along the entire surface of a cylinder is solved numerically using the Keller-box scheme. The obtained results are compared with the ones from the open literature, and it is shown that the agreement is very good.

  10. Expression of matrix metrallproteinase-2 in human tears fluid after LASIK

    Directory of Open Access Journals (Sweden)

    Ai-Wei Chen

    2014-12-01

    Full Text Available AIM: To monitor long-term changes of matrix metalloproteinase-2(MMP-2in human tears fluid after laser in situ keratomileusis(LASIK. METHODS: Thirty-two myopia cases(64 eyesunderwent uneventful LASIK were enrolled in the study. Tear fluid were collected and MMP-2 expression was analyzed by Western-bolt assay preoperatively and postoperatively on 15d, at 1, 3mo, and 1a. RESULTS: LASIK increased the concentration of MMP-2 in human tear fluid. At 15d postoperatively, the magnitude of MMP-2 was 1.4 times that of preoperative, thereafter subsided, but didn't return to preoperative level by 3mo(PP>0.05. CONCLUSION: MMP-2 is significantly expressed in human tear fluid after LASIK, then subsided with time, but didn't return to preoperative level by 3mo and almost recovered up to 1a, indicating wound healing of LASIK would continue up at least 3mo after surgery and almost recovered 1a postoperatively.

  11. Material Exchange and Migration between Pore Fluids and Sandstones during Diagenetic Processes in Rift Basins: A Case Study Based on Analysis of Diagenetic Products in Dongying Sag, Bohai Bay Basin, East China

    Directory of Open Access Journals (Sweden)

    W. Meng

    2018-01-01

    Full Text Available The exchange and migration of basin materials that are carried by pore fluids are the essence of diagenesis, which can alter physical properties of clastic rocks as well as control formation and distribution of favorable reservoirs of petroliferous basins. Diagenetic products and pore fluids, resulting from migration and exchange of basin materials, can be used to deduce those processes. In this study, 300 core samples from 46 wells were collected for preparation of casting thin sections, SEM, BSE, EDS, inclusion analysis, and isotope analysis in Dongying Sag, Bohai Bay Basin, East China. Combined with geochemical characteristics of pore fluids and geological background of the study area, the source and exchange mechanisms of materials in the pore fluids of rift basins were discussed. It was revealed that the material exchange of pore fluids could be divided into five stages. The first stage was the evaporation concentration stage during which mainly Ca2+, Mg2+, and CO32- precipitated as high-Mg calcites. Then came the shale compaction stage, when mainly Ca2+ and CO32- from shale compaction water precipitated as calcites. The third stage was the carboxylic acid dissolution stage featured by predominant dissolution of plagioclases, during which Ca2+ and Na+ entered pore fluids, and Si and Al also entered pore fluids and then migrated as clathrates, ultimately precipitating as kaolinites. The fourth stage was the organic CO2 stage, mainly characterized by the kaolinization of K-feldspar as well as dissolution of metamorphic lithic fragments and carbon cements. During this stage, K+, Fe2+, Mg2+, Ca2+, HCO3-, and CO32- entered pore fluids. The fifth stage was the alkaline fluid stage, during which the cementation of ferro-carbonates and ankerites as well as illitization or chloritization of kaolinites prevailed, leading to the precipitation of K+, Fe2+, Mg2+, Ca2+, and CO32- from pore fluids.

  12. Experimental study on fluid mixing phenomena in T-pipe junction with upstream elbow

    International Nuclear Information System (INIS)

    Hiroshi Ogawa; Minoru Igarashi; Nobuyuki Kimura; Hideki Kamide

    2005-01-01

    Full text of publication follows: Temperature fluctuation in fluid causes high cycle thermal fatigue in shroud structure according to its amplitude and frequency. There are still some incidents of thermal fatigue and leakage in light water reactors (Japanese PWR Tomari-2 in 2003, French PWR CIVAUX in 1998), and also in sodium cooled reactors (French FBR Phenix in 1992). Mixing tee is a typical component where temperature fluctuation occurs. Water experiment has been carried out to investigate temperature fluctuation characteristics and flow velocity field in a simple T-pipe junction with straight inlet pipings for main and branch lines; test facility is named as WATLON (Water Experiment on Fluid Mixing in T-pipe with Long Cycle Fluctuation). Here, influence of upstream elbow in the main pipe was studied in the WATLON facility. Elbow can be set near the mixing tee in a real plant. Outlet of the elbow has biased velocity distribution and also the secondary flow, which decays unsteadily. Temperature distribution in the mixing tee was measured by a movable tree with 17 thermocouples and velocity field was measured by Dynamic PIV (high speed particle image velocimetry) with sampling frequency of 200 Hz. Measured temperature showed that fluctuation intensity near the wall was larger in the elbow geometry than in the straight inlet pipes in a case of wall jet (branch flow velocity is smaller than main pipe flow velocity); high intensity region in the elbow case was enlarged around the jet exiting from the branch pipe. The result of flow velocity measurement showed that secondary flow and biased flow velocity distributions due to the elbow influenced bending of the jet exiting from the branch pipe and the temperature fluctuation intensity around the jet. The detailed flow velocity distributions and the secondary flow of upstream elbow can be measured by Dynamic PIV. Influence of such elbow was discussed based on detailed temperature data together with fluctuated velocity

  13. An analytical and numerical study of peristaltic transport of a Johnson—Segalman fluid in an endoscope

    International Nuclear Information System (INIS)

    Akbar, Noreen Sher; Nadeem, S.

    2013-01-01

    In the present study, we discuss the peristaltic flow of a Johnson—Segalman fluid in an endoscope. Perturbation, homotopy, and numerical solutions are found for the non-linear differential equation. The comparative study is also made to check the validity of the solutions. The expressions for pressure rise frictional forces, pressure gradient, and stream lines are presented to interpret the behavior of various physical quantities of the Johnson—Segalman fluid. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    Science.gov (United States)

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  15. Bioimpedance-Guided Fluid Management in Hemodialysis Patients

    Science.gov (United States)

    Arias-Guillén, Marta; Wabel, Peter; Fontseré, Néstor; Carrera, Montserrat; Campistol, José Maria; Maduell, Francisco

    2013-01-01

    Summary Background and objectives Achieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients. Design, setting, participants, & measurements Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5±0.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol. Results Time-averaged fluid overload in the complete study cohort was 0.9±1.6 L at baseline and 0.6±1.1 L at study end. Time-averaged fluid overload decreased by −1.20±1.32 L (P<0.01) in the fluid-overloaded group (n=17), remained unchanged in the normovolemic group (n=26, P=0.59), and increased by 0.59±0.76 L (P=0.02) in the dehydrated group (n=12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg/L change in predialysis systolic BP (r=0.55, P<0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups. Conclusions Active fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP. PMID:23949235

  16. A Study Of Magnetic Fluid Based Squeeze Film Between Porous ...

    African Journals Online (AJOL)

    Efforts have been made to study and analyze the effect of surface roughness on the performance of magnetic fluid based squeeze film between porous elliptic plates. The transverse roughness of the bearing surface is characterized by a stochastic random variable with non-zero mean, variance and skewness.

  17. Scrutinization of thermal radiation, viscous dissipation and Joule heating effects on Marangoni convective two-phase flow of Casson fluid with fluid-particle suspension

    Science.gov (United States)

    Mahanthesh, B.; Gireesha, B. J.

    2018-03-01

    The impact of Marangoni convection on dusty Casson fluid boundary layer flow with Joule heating and viscous dissipation aspects is addressed. The surface tension is assumed to vary linearly with temperature. Physical aspects of magnetohydrodynamics and thermal radiation are also accounted. The governing problem is modelled under boundary layer approximations for fluid phase and dust particle phase and then Runge-Kutta-Fehlberg method based numeric solutions are established. The momentum and heat transport mechanisms are focused on the result of distinct governing parameters. The Nusselt number is also calculated. It is established that the rate of heat transfer can be enhanced by suspending dust particles in the base fluid. The temperature field of fluid phase and temperature of dust phase are quite reverse for thermal dust parameter. The radiative heat, viscous dissipation and Joule heating aspects are constructive for thermal fields of fluid and dust phases. The velocity of dusty Casson fluid dominates the velocity of dusty fluid while this trend is opposite in the case of temperature. Moreover qualitative behaviour of fluid phase and dust phase temperature/velocity are similar.

  18. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  19. The use of paleo-thermo-barometers and coupled thermal, fluid flow and pore fluid pressure modelling for hydrocarbon and reservoir prediction in fold and thrust belts

    NARCIS (Netherlands)

    Roure, F.; Andriessen, P.A.M.; Callot, J.P.; Ferket, H.; Gonzales, E.; Guilhaumou, N.; Hardebol, N.J.; Lacombe, O.; Malandain, J.; Mougin, P.; Muska, K.; Ortuno, S.; Sassi, W.; Swennen, R.; Vilasi, N.

    2010-01-01

    Basin modelling tools are now more efficient to reconstruct palinspastic structural cross sections and compute the history of temperature, pore-fluid pressure and fluid flow circulations in complex structural settings. In many cases and especially in areas where limited erosion occurred, the use of

  20. Rheological and filtration characteristics of drilling fluids enhanced by nanoparticles with selected additives: an experimental study

    Directory of Open Access Journals (Sweden)

    Nima Mohamadian

    2018-05-01

    Full Text Available The suspension properties of drilling fluids containing pure and polymer-treated (partially-hydrolyzed polyacrylamide (PHPA or Xanthan gum clay nanoparticles are compared withthose of a conventional water-and-bentonite-based drilling fluid, used as the referencesample. Additionally, the mud weight, plastic viscosity, apparent viscosity, yield point, primary and secondary gelatinization properties, pH, and filtration properties of the various drilling fluids studied are also measured and compared. The performance of each drilling fluid type is evaluated with respect in terms of its ability to reduce mud cake thickness and fluid loss thereby inhibiting differential-pipe-sticking. For that scenario, the mud-cake thickness is varied, and the filtration properties of the drilling fluids are measured as an indicator of potential well-diameter reduction, caused by mud cake, adjacent to permeable formations. The novel results show that nanoparticles do significantly enhance the rheological and filtration characteristics of drilling fluids. A pure-clay-nanoparticle suspension, without any additives, reduced fluid loss to about 42% and reduced mud cake thickness to 30% compared to the reference sample. The xanthan-gum-treated-clay-nanoparticle drilling fluid showed good fluid loss control and reduced fluid loss by 61% compared to the reference sample. The presence of nanofluids also leads to reduced mud-cake thicknesses, directly mitigating the risks of differential pipe sticking.

  1. Working fluid selection for organic Rankine cycles - Impact of uncertainty of fluid properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Andreasen, Jesper Graa; Liu, Wei

    2016-01-01

    of processmodels and constraints 2) selection of property models, i.e. Penge Robinson equation of state 3)screening of 1965 possible working fluid candidates including identification of optimal process parametersbased on Monte Carlo sampling 4) propagating uncertainty of fluid parameters to the ORC netpower output......This study presents a generic methodology to select working fluids for ORC (Organic Rankine Cycles)taking into account property uncertainties of the working fluids. A Monte Carlo procedure is described as a tool to propagate the influence of the input uncertainty of the fluid parameters on the ORC....... The net power outputs of all the feasible working fluids were ranked including their uncertainties. The method could propagate and quantify the input property uncertainty of the fluidproperty parameters to the ORC model, giving an additional dimension to the fluid selection process. In the given analysis...

  2. A Numerical Study of Mesh Adaptivity in Multiphase Flows with Non-Newtonian Fluids

    Science.gov (United States)

    Percival, James; Pavlidis, Dimitrios; Xie, Zhihua; Alberini, Federico; Simmons, Mark; Pain, Christopher; Matar, Omar

    2014-11-01

    We present an investigation into the computational efficiency benefits of dynamic mesh adaptivity in the numerical simulation of transient multiphase fluid flow problems involving Non-Newtonian fluids. Such fluids appear in a range of industrial applications, from printing inks to toothpastes and introduce new challenges for mesh adaptivity due to the additional ``memory'' of viscoelastic fluids. Nevertheless, the multiscale nature of these flows implies huge potential benefits for a successful implementation. The study is performed using the open source package Fluidity, which couples an unstructured mesh control volume finite element solver for the multiphase Navier-Stokes equations to a dynamic anisotropic mesh adaptivity algorithm, based on estimated solution interpolation error criteria, and conservative mesh-to-mesh interpolation routine. The code is applied to problems involving rheologies ranging from simple Newtonian to shear-thinning to viscoelastic materials and verified against experimental data for various industrial and microfluidic flows. This work was undertaken as part of the EPSRC MEMPHIS programme grant EP/K003976/1.

  3. Unsteady flow of fractional Oldroyd-B fluids through rotating annulus

    Science.gov (United States)

    Tahir, Madeeha; Naeem, Muhammad Nawaz; Javaid, Maria; Younas, Muhammad; Imran, Muhammad; Sadiq, Naeem; Safdar, Rabia

    2018-04-01

    In this paper exact solutions corresponding to the rotational flow of a fractional Oldroyd-B fluid, in an annulus, are determined by applying integral transforms. The fluid starts moving after t = 0+ when pipes start rotating about their axis. The final solutions are presented in the form of usual Bessel and hypergeometric functions, true for initial and boundary conditions. The limiting cases for the solutions for ordinary Oldroyd-B, fractional Maxwell and Maxwell and Newtonian fluids are obtained. Moreover, the solution is obtained for the fluid when one pipe is rotating and the other one is at rest. At the end of this paper some characteristics of fluid motion, the effect of the physical parameters on the flow and a correlation between different fluid models are discussed. Finally, graphical representations confirm the above affirmation.

  4. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  5. Changes in the peritoneal fluid of horses with abdominal discomfort and its relations to the kind and evolution of the lesion after medical or surgical treatment: study of 74 cases

    Directory of Open Access Journals (Sweden)

    Raquel Yvonne Arantes Baccarin

    1995-12-01

    Full Text Available The purpose of this paper is to view the interrelation between the peritoneal fluid analysis from horses with abdominal discomfort, regarding the pathology site, the occurrence or not of strangulating obstruction, the treatment performed and the presence of peritoneal fluid, classified either as modified transudate or exsudate. In order to achieve that, 373 clinical records of colicky horses referred to the Veterinary Hospital between 1985 and 1991 were studied, and 98 of these, were selected, in which peritoneal fluid sampling and analysis had been carried out in a routine manner. Greater amount of exsudate than that of modified transudate was observed. Horses with wide spread intestinal disease showed the best recovery rates. Regardless of the site of the lesion, those exhibiting strangulating obstruction had the lowest rates of survival, and this kind of obstruction was more frequently observed in the small intestine. Among the parameters considered in the peritoneal fluid analysis, fluid color was the most reliable indicator od strangulating obstruction and/or intestinal ischemia. Finally, peritoneal fluid analysis and citology alone were not sufficient to diagnose the cause of the colic, due to the great variation observed in each pathology group: associated to the clinical evaluation of the patient, however, they can bring up the need for surgical intervention.

  6. Design and numerical study of turbines operating with MDM as working fluid

    Science.gov (United States)

    Klonowicz, Piotr; Surwiło, Jan; Witanowski, Łukasz; Suchocki, Tomasz K.; Kozanecki, Zbigniew; Lampart, Piotr

    2015-12-01

    Design processes and numerical simulations have been presented for a few cases of turbines designated to work in ORC systems. The chosen working fluid isMDM. The considered design configurations include single stage centripetal reaction and centrifugal impulse turbines as well as multistage axial turbines. The power outputs vary from about 75 kW to 1 MW. The flow in single stage turbines is supersonic and requires special design of blades. The internal efficiencies of these configurations exceed 80% which is considered high for these type of machines. The efficiency of axial turbines exceed 90%. Possible turbine optimization directions have been also outlined in the work.

  7. Cerebrospinal fluid hypovolemia syndrome with benign course

    Directory of Open Access Journals (Sweden)

    Ramesha K

    2010-01-01

    Full Text Available Background: The cerebrospinal fluid hypovolemia syndrome (CHS is an under recognized cause of headache. This study was designed to highlight the clinico-radiological and cerebrospinal fluid (CSF picture of CHS and their long-term outcome from a tertiary referral center. Materials and Methods: The CHS was diagnosed on the basis of the criteria proposed by Chung et al. Cases with CSF rhinorrhoea or other CSF leak or head trauma were excluded from the study. Results: The study included eight consecutive cases of CHS diagnosed over the past 7 years from 2001. The mean age at diagnosis was 40.7 years (range, 34-56 years and male-to-female ratio was 1:3. All patients presented with orthostatic headache of subacute onset and normal neurological examination. Magnetic resonance imaging studies of all patients showed hyperintensity of pachymeninges in T2W sequences, venous distension sign, and diffuse pachymeningeal gadolinium enhancement. The descent of the brainstem and subdural effusion were noted in two each (25%. CSF study (n = 5 showed low opening pressure in three (60%, and mild pleocytosis with elevated protein in two each (40%. The mean time to complete recovery with conservative treatment alone was 25.6 days. All radiological signs disappeared with clinical improvement in three patients where follow-up imaging was done. On mean follow-up period of 3.6 years, all were asymptomatic without any recurrence of CHS. Conclusion: CHS can resolve completely with conservative management and intervention with subdural blood patch or surgical repair would be required only if symptoms persist for more than 1 month.

  8. Convergence acceleration for partitioned simulations of the fluid-structure interaction in arteries

    Science.gov (United States)

    Radtke, Lars; Larena-Avellaneda, Axel; Debus, Eike Sebastian; Düster, Alexander

    2016-06-01

    We present a partitioned approach to fluid-structure interaction problems arising in analyses of blood flow in arteries. Several strategies to accelerate the convergence of the fixed-point iteration resulting from the coupling of the fluid and the structural sub-problem are investigated. The Aitken relaxation and variants of the interface quasi-Newton -least-squares method are applied to different test cases. A hybrid variant of two well-known variants of the interface quasi-Newton-least-squares method is found to perform best. The test cases cover the typical boundary value problem faced when simulating the fluid-structure interaction in arteries, including a strong added mass effect and a wet surface which accounts for a large part of the overall surface of each sub-problem. A rubber-like Neo Hookean material model and a soft-tissue-like Holzapfel-Gasser-Ogden material model are used to describe the artery wall and are compared in terms of stability and computational expenses. To avoid any kind of locking, high-order finite elements are used to discretize the structural sub-problem. The finite volume method is employed to discretize the fluid sub-problem. We investigate the influence of mass-proportional damping and the material model chosen for the artery on the performance and stability of the acceleration strategies as well as on the simulation results. To show the applicability of the partitioned approach to clinical relevant studies, the hemodynamics in a pathologically deformed artery are investigated, taking the findings of the test case simulations into account.

  9. Fluid mechanics as a driver of tissue-scale mechanical signaling in organogenesis.

    Science.gov (United States)

    Gilbert, Rachel M; Morgan, Joshua T; Marcin, Elizabeth S; Gleghorn, Jason P

    2016-12-01

    Organogenesis is the process during development by which cells self-assemble into complex, multi-scale tissues. Whereas significant focus and research effort has demonstrated the importance of solid mechanics in organogenesis, less attention has been given to the fluid forces that provide mechanical cues over tissue length scales. Fluid motion and pressure is capable of creating spatial gradients of forces acting on cells, thus eliciting distinct and localized signaling patterns essential for proper organ formation. Understanding the multi-scale nature of the mechanics is critically important to decipher how mechanical signals sculpt developing organs. This review outlines various mechanisms by which tissues generate, regulate, and sense fluid forces and highlights the impact of these forces and mechanisms in case studies of normal and pathological development.

  10. [Forensic medical characteristic of the thermal injury caused by inflammation of combustible fluids].

    Science.gov (United States)

    Khushkadamov, Z K; Iskhizova, L N; Gornostaev, D V

    2012-01-01

    The diagnostics of thermal injuries caused by inflammation of combustible fluids should be based on the comprehensive assessment of the results of examination of the scene of the accident, autopsy studies, forensic chemical expertise, and analysis of the circumstances of the case and/or medical documentation. Special attention should be given to the choice of adequate methods for taking samples to be used in forensic chemical studies. The assessment of thermal injuries caused by inflammation of combustible fluids must take into consideration the time and conditions under which they were inflicted (e.g. closed or open space, vertical or horizontal position, etc.).

  11. Two-fluid model for locomotion under self-confinement

    Science.gov (United States)

    Reigh, Shang Yik; Lauga, Eric

    2017-09-01

    The bacterium Helicobacter pylori causes ulcers in the stomach of humans by invading mucus layers protecting epithelial cells. It does so by chemically changing the rheological properties of the mucus from a high-viscosity gel to a low-viscosity solution in which it may self-propel. We develop a two-fluid model for this process of swimming under self-generated confinement. We solve exactly for the flow and the locomotion speed of a spherical swimmer located in a spherically symmetric system of two Newtonian fluids whose boundary moves with the swimmer. We also treat separately the special case of an immobile outer fluid. In all cases, we characterize the flow fields, their spatial decay, and the impact of both the viscosity ratio and the degree of confinement on the locomotion speed of the model swimmer. The spatial decay of the flow retains the same power-law decay as for locomotion in a single fluid but with a decreased magnitude. Independent of the assumption chosen to characterize the impact of confinement on the actuation applied by the swimmer, its locomotion speed always decreases with an increase in the degree of confinement. Our modeling results suggest that a low-viscosity region of at least six times the effective swimmer size is required to lead to swimming with speeds similar to locomotion in an infinite fluid, corresponding to a region of size above ≈25 μ m for Helicobacter pylori.

  12. Interpreting Students’ Perceptions in Fluid Mechanics Learning Outcomes

    Directory of Open Access Journals (Sweden)

    Filomena SOARES

    2015-11-01

    Full Text Available The objective of this study is to analyse the impact of introducing a practical work in the learning process of the Fluid Transport Systems course in Chemical Engineering degree. The students, in groups of two or three elements, were free to choose the application case in order to develop the practical work proposed by the responsible teachers. The students selected a centrifugal pump to supply water to houses or buildings and designed the piping system. The practical work was evaluated through the written report. The students’ perceptions were analysed through a questionnaire. The learning outcomes were also considered in order to understand how the fluid mechanics concepts were acquired. In the teachers’ point of view the teamwork should enable the development of students’ soft skills and competencies, promoting the ability to integrate and work in teams. The students changed their learning processing and perception becoming more reflective and less accommodative, forcing them to think critically and share opinions. Regarding the Fluid Mechanics assessment, the practical work increased, in average, the final grade at least one value.

  13. Raman spectroscopic signature of vaginal fluid and its potential application in forensic body fluid identification.

    Science.gov (United States)

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K

    2012-03-10

    Traces of human body fluids, such as blood, saliva, sweat, semen and vaginal fluid, play an increasingly important role in forensic investigations. However, a nondestructive, easy and rapid identification of body fluid traces at the scene of a crime has not yet been developed. The obstacles have recently been addressed in our studies, which demonstrated the considerable potential of Raman spectroscopy. In this study, we continued to build a full library of body fluid spectroscopic signatures. The problems concerning vaginal fluid stain identification were addressed using Raman spectroscopy coupled with advanced statistical analysis. Calculated characteristic Raman and fluorescent spectral components were used to build a multidimensional spectroscopic signature of vaginal fluid, which demonstrated good specificity and was able to handle heterogeneous samples from different donors. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. MHD Boundary Layer Flow of Dilatant Fluid in a Divergent Channel with Suction or Blowing

    International Nuclear Information System (INIS)

    Bhattacharyya, Krishnendu; Layek, G. C.

    2011-01-01

    An analysis is carried out to study a steady magnetohydrodynamic (MHD) boundary layer flow of an electrically conducting incompressible power-law non-Newtonian fluid through a divergent channel. The channel walls are porous and subjected to either suction or blowing of equal magnitude of the same kind of fluid on both walls. The fluid is permeated by a magnetic field produced by electric current along the line of intersection of the channel walls. The governing partial differential equation is transformed into a self-similar nonlinear ordinary differential equation using similarity transformations. The possibility of boundary layer flow in a divergent channel is analyzed with the power-law fluid model. The analysis reveals that the boundary layer flow (without separation) is possible for the case of the dilatant fluid model subjected to suitable suction velocity applied through its porous walls, even in the absence of a magnetic field. Further, it is found that the boundary layer flow is possible even in the presence of blowing for a suitable value of the magnetic parameter. It is found that the velocity increases with increasing values of the power-law index for the case of dilatant fluid. The effects of suction/blowing and magnetic field on the velocity are shown graphically and discussed physically. (fundamental areas of phenomenology(including applications))

  15. Fluid Mechanics and Fluid Power (FMFP)

    Indian Academy of Sciences (India)

    Amitabh Bhattacharya

    of renewable energy (e.g., via wind, hydrokinetic generators), creating low-cost healthcare ... multiphase flow, turbulence, bio-fluid dynamics, atmospheric flows, microfluidic flows, and ... study the challenging problem of entry of solids in water.

  16. Subretinal fluid is common in experimental non-arteritic anterior ischemic optic neuropathy

    Science.gov (United States)

    Yu, C; Ho, J K; Liao, Y J

    2014-01-01

    Purpose Anterior ischemic optic neuropathy (AION) is an important cause of acute vision loss for which several animal models exist. It has been associated with subretinal fluid in a previous study on patients but not yet so in animal models. Patients and Methods A patient presented with acute non-arteritic AION (NAION) and underwent ophthalmic evaluation and testing including fluorescein angiography and spectral-domain optical coherence tomography (SD-OCT). On the basis of the patient's findings, we used SD-OCT circular and volume scans to analyze retinal changes in a murine model of NAION. Results One week after left eye vision loss, the patient had clinical and imaging findings consistent with NAION. On SD-OCT, there was prominent peripapillary retinal thickening consistent with intra-retinal edema and sub-foveolar fluid. Inspired by the findings in human AION, we looked for similar changes in murine NAION using SD-OCT. The circular scan did not adequately detect the presence of subretinal fluid. Using the 25-line scan, which covered a larger part of the posterior pole, we found that 100% of murine AION resulted in subretinal fluid at day 1. The subretinal fluid resolved by week 1. Conclusion This study detailed a case of clinical NAION associated with intra-retinal and subretinal fluid. We also found that subretinal fluid was common in murine photochemical thrombosis model of AION and could be found far away from the optic disc. PMID:25257770

  17. The Motion Of A Deformable Body In - Bounded Fluid

    International Nuclear Information System (INIS)

    Galpert, A.R.; Miloh, T.

    1998-01-01

    The Hamiltonian formalism for the motion of a deformable body in an inviscid irrotational fluid is generalized for the case of the motion in a bounded fluid. We found that the presence of the boundaries in a liquid leads to the chaotization of the body's motion. The ('memory' effect connected with a free surface boundary condition is also accounted for

  18. An Efficient Sleepy Algorithm for Particle-Based Fluids

    Directory of Open Access Journals (Sweden)

    Xiao Nie

    2014-01-01

    Full Text Available We present a novel Smoothed Particle Hydrodynamics (SPH based algorithm for efficiently simulating compressible and weakly compressible particle fluids. Prior particle-based methods simulate all fluid particles; however, in many cases some particles appearing to be at rest can be safely ignored without notably affecting the fluid flow behavior. To identify these particles, a novel sleepy strategy is introduced. By utilizing this strategy, only a portion of the fluid particles requires computational resources; thus an obvious performance gain can be achieved. In addition, in order to resolve unphysical clumping issue due to tensile instability in SPH based methods, a new artificial repulsive force is provided. We demonstrate that our approach can be easily integrated with existing SPH based methods to improve the efficiency without sacrificing visual quality.

  19. A numerical model of two-phase flow at the micro-scale using the volume-of-fluid method

    Science.gov (United States)

    Shams, Mosayeb; Raeini, Ali Q.; Blunt, Martin J.; Bijeljic, Branko

    2018-03-01

    This study presents a simple and robust numerical scheme to model two-phase flow in porous media where capillary forces dominate over viscous effects. The volume-of-fluid method is employed to capture the fluid-fluid interface whose dynamics is explicitly described based on a finite volume discretization of the Navier-Stokes equations. Interfacial forces are calculated directly on reconstructed interface elements such that the total curvature is preserved. The computed interfacial forces are explicitly added to the Navier-Stokes equations using a sharp formulation which effectively eliminates spurious currents. The stability and accuracy of the implemented scheme is validated on several two- and three-dimensional test cases, which indicate the capability of the method to model two-phase flow processes at the micro-scale. In particular we show how the co-current flow of two viscous fluids leads to greatly enhanced flow conductance for the wetting phase in corners of the pore space, compared to a case where the non-wetting phase is an inviscid gas.

  20. Intrapartum amnioinfusion in meconium-stained liquor: a case-control study.

    Science.gov (United States)

    Bansal, Neeta; Gupta, Vineeta; Nanda, Anuja; Chaudhary, Priyanka; Tandon, Archna; Behl, Neelima

    2013-06-01

    The aim of this study was to investigate perinatal outcome and the rate of cesarean section (CS) following intrapartum amnioinfusion in women with meconium-stained amniotic fluid (MSAF). A total of 100 women at term in labor with meconium were randomized to infuse transcervical intrapartum amnioinfusion with saline (50) and routine obstetrical care (50). Perinatal outcome and obstetric outcome were recorded and analyzed in both groups by means of Chi-square test. The CS rate due to fetal distress was 40.0 % in the control group and 20.0 % in the study group. The difference was statistically significant (P Amnioinfusion in cases of meconium-stained liquor significantly improved neonatal outcome and CS rate without increasing any maternal and fetal complications.

  1. Helicopter fuselage drag - combined computational fluid dynamics and experimental studies

    Science.gov (United States)

    Batrakov, A.; Kusyumov, A.; Mikhailov, S.; Pakhov, V.; Sungatullin, A.; Valeev, M.; Zherekhov, V.; Barakos, G.

    2015-06-01

    In this paper, wind tunnel experiments are combined with Computational Fluid Dynamics (CFD) aiming to analyze the aerodynamics of realistic fuselage configurations. A development model of the ANSAT aircraft and an early model of the AKTAI light helicopter were employed. Both models were tested at the subsonic wind tunnel of KNRTU-KAI for a range of Reynolds numbers and pitch and yaw angles. The force balance measurements were complemented by particle image velocimetry (PIV) investigations for the cases where the experimental force measurements showed substantial unsteadiness. The CFD results were found to be in fair agreement with the test data and revealed some flow separation at the rear of the fuselages. Once confidence on the CFD method was established, further modifications were introduced to the ANSAT-like fuselage model to demonstrate drag reduction via small shape changes.

  2. An experimental study on the effects of rectifiers on fluid flow

    International Nuclear Information System (INIS)

    Kawashima, G.

    1985-01-01

    This paper reports studies of various combinations of rectifiers and rectifying nets to measure fluid flow and in particular, the measurement of the flow through an orifice or nozzle, since they help to shorten the inlet length

  3. Using Neutrons to Study Fluid-Rock Interactions in Shales

    Science.gov (United States)

    DiStefano, V. H.; McFarlane, J.; Anovitz, L. M.; Gordon, A.; Hale, R. E.; Hunt, R. D.; Lewis, S. A., Sr.; Littrell, K. C.; Stack, A. G.; Chipera, S.; Perfect, E.; Bilheux, H.; Kolbus, L. M.; Bingham, P. R.

    2015-12-01

    Recovery of hydrocarbons by hydraulic fracturing depends on complex fluid-rock interactions that we are beginning to understand using neutron imaging and scattering techniques. Organic matter is often thought to comprise the majority of porosity in a shale. In this study, correlations between the type of organic matter embedded in a shale and porosity were investigated experimentally. Selected shale cores from the Eagle Ford and Marcellus formations were subjected to pyrolysis-gas chromatography, Differential Thermal Analysis/Thermogravimetric analysis, and organic solvent extraction with the resulting affluent analyzed by gas chromatography-mass spectrometry. The pore size distribution of the microporosity (~1 nm to 2 µm) in the Eagle Ford shales was measured before and after solvent extraction using small angle neutron scattering. Organics representing mass fractions of between 0.1 to 1 wt.% were removed from the shales and porosity generally increased across the examined microporosity range, particularly at larger pore sizes, approximately 50 nm to 2 μm. This range reflects extraction of accessible organic material, including remaining gas molecules, bitumen, and kerogen derivatives, indicating where the larger amount of organic matter in shale is stored. An increase in porosity at smaller pore sizes, ~1-3 nm, was also present and could be indicative of extraction of organic material stored in the inter-particle spaces of clays. Additionally, a decrease in porosity after extraction for a sample was attributed to swelling of pores with solvent uptake. This occurred in a shale with high clay content and low thermal maturity. The extracted hydrocarbons were primarily paraffinic, although some breakdown of larger aromatic compounds was observed in toluene extractions. The amount of hydrocarbon extracted and an overall increase in porosity appeared to be primarily correlated with the clay percentage in the shale. This study complements fluid transport neutron

  4. Jet meandering by a foil pitching in quiescent fluid

    Science.gov (United States)

    Shinde, Sachin Y.; Arakeri, Jaywant H.

    2013-04-01

    The flow produced by a rigid symmetric NACA0015 airfoil purely pitching at a fixed location in quiescent fluid (the limiting case of infinite Strouhal number) is studied using visualizations and particle image velocimetry. A weak jet is generated whose inclination changes continually with time. This meandering is observed to be random and independent of the initial conditions, over a wide range of pitching parameters.

  5. Mathematical and numerical modelling of fluids at Nano-metric scales

    International Nuclear Information System (INIS)

    Joubaud, R.

    2012-01-01

    This work presents some contributions to the mathematical and numerical modelling of fluids at Nano-metric scales. We are interested in two levels of modelling. The first level consists in an atomic description. We consider the problem of computing the shear viscosity of a fluid from a microscopic description. More precisely, we study the mathematical properties of the nonequilibrium Langevin dynamics allowing to compute the shear viscosity. The second level of description is a continuous description, and we consider a class of continuous models for equilibrium electrolytes, which incorporate on the one hand a confinement by charged solid objects and on the other hand non-ideality effects stemming from electrostatic correlations and steric exclusion phenomena due to the excluded volume effects. First, we perform the mathematical analysis of the case where the free energy is a convex function (mild non-ideality). Second, we consider numerically the case where the free energy is a non convex function (strong non-ideality) leading in particular to phase separation. (author)

  6. Spectra of primordial fluctuations in two-perfect-fluid regular bounces

    International Nuclear Information System (INIS)

    Finelli, Fabio; Peter, Patrick; Pinto-Neto, Nelson

    2008-01-01

    We introduce analytic solutions for a class of two components bouncing models, where the bounce is triggered by a negative energy density perfect fluid. The equation of state of the two components are constant in time, but otherwise unrelated. By numerically integrating regular equations for scalar cosmological perturbations, we find that the (would-be) growing mode of the Newtonian potential before the bounce never matches with the growing mode in the expanding stage. For the particular case of a negative energy density component with a stiff equation of state we give a detailed analytic study, which is in complete agreement with the numerical results. We also perform analytic and numerical calculations for long wavelength tensor perturbations, obtaining that, in most cases of interest, the tensor spectral index is independent of the negative energy fluid and given by the spectral index of the growing mode in the contracting stage. We compare our results with previous investigations in the literature

  7. Using Temperature as a Tracer to Study Fluid Flow Patterns On and Offshore Taiwan

    Science.gov (United States)

    Chi, W. C.

    2017-12-01

    Fluid flows are a dynamic system in the crust that affect crustal deformation and formation of natural resources. It is difficult to study fluid flow velocity instrumentally, but temperature data offers a quantitative tool that can be used as a tracer to study crustal hydrogeology. Here we present numerical techniques we have applied to study the fluid migration velocity along conduits including faults in on and offshore settings. Offshore SW Taiwan, we use a bottom-simulating reflector (BSR) from seismic profiles to study the temperature field at several hundred meters subbottom depth. The BSR is interpreted as the base of a gas hydrate stability zone under the seabed. Gas hydrates are solid-state water with gas molecules enclosed, which can be found where the temperature, pressure, and salinity conditions allow hydrates to be stable. Using phase diagrams and hydro pressure information we can derive the temperature at the BSR. BSRs are widespread in the study area, providing very dense temperature field information which shows upward bending of the BSR near faults. We have quantitatively estimated the 1D and 2D fluid flow patterns required to fit the BSR-based temperature field. This shows that fault zones can act as conduits with high permeability parallel to the fault planes. On the other hand, fault zones can also act as barriers to fluid flow, as demonstrated in our onland temperature data. We have collected temperature profiles at several bore holes onland that are very close together. The preliminary results show that the fault zones separate the ground water systems, causing very different geothermal gradients. Our results show that the physical properties of fault zones can be anisotropic, as demonstrated in previous work. Future work includes estimating the regional water expulsion budget offshore SW Taiwan, in particular for several gas hydrate sites.

  8. Study of Mururoa's basaltic massif alteration (French Polynesia): solid and fluid phases analysis and thermodynamical modeling

    International Nuclear Information System (INIS)

    Destrigneville, Christine

    1991-01-01

    The alteration processes occurring in the volcanics of Mururoa have been studied using petrological data on secondary minerals, chemical analyses of the interstitial fluids and isotopic analyses on both minerals and fluids. Chemical and isotopic exchanges were first modelled, then thermodynamical modeling characterized the chemical evolution during the alteration of the secondary assemblage and of the fluid. The main secondary sequences which have been observed in Mururoa volcanics result from the alteration occurring during the lavas setting. Two different processes have been evidenced. The first one is the deuteric alteration with the CO_2-rich magmatic fluid exsolved from the magma and trapped in the vesicles and the olivine microcracks of the lava intrusions. This alteration in a closed system is dominated by the solid phases when the CO_2 molar fraction in the fluid is higher than 0.25. The second process is the alteration of the lavas by seawater or a meteoric fluid. The basaltic flows present alteration assemblages composed of clay minerals and zeolites whose chemical composition has been forced by the fluid composition. Shallowness emissions of lavas result in completely argillized levels. The present interstitial fluids chemistry result from the percolation of seawater in the volcano. In the argillized levels the fluids have interacted with the clay minerals and their chemical compositions have been modified. The important chemical changes in the present interstitial fluids show that the present alteration in the volcano is higher than the fluids circulation. (author) [fr

  9. Fluid extravasation of the articular capsule as a complication of temporomandibular joint pumping and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Kenichi; Watahiki, Ryuichirou; Tamura, Hidetoshi; Ogura, Motoi; Shibuya, Masayuki [Kameda General Hospital, Kamogawa, Chiba (Japan)

    2002-11-01

    This report is a retrospective study of fluid extravasation as a complication of temporomandibular joint pumping and perfusion. Contrast-enhanced 3D-CT of the upper joint compartment was performed for presurgical diagnosis before temporomandibular joint arthroscopic surgery in our hospital from 1996 to 2000. From these cases, 43 joints and 38 patients were selected because they had not improved under conservative treatment during the previous six months. Fluid extravasation of the articular capsule was recognized in 9 joints (20.9%) in 9 patients, 3 males and 6 females. Two of the nine patients had undergone arthroscopic observation before surgery. This test had revealed only thin articular capsule, not a perforation, in any of these cases. The data indicate only extremely tiny perforations or infiltration leakage due to the fluid pressure in the upper joint compartment during pumping or perfusion. Oral and maxillofacial surgeons should be aware of this complication. (author)

  10. Study on an alternating current electrothermal micropump for microneedle-based fluid delivery systems

    Science.gov (United States)

    Zhang, Rumi; Jullien, Graham A.; Dalton, Colin

    2013-07-01

    In this paper, we report on a modeling study of an AC electrothermal (ACET) micropump with high operating pressures as well as fast flow rates. One specific application area is for fluid delivery using microneedle arrays which require higher pressures and faster flow rates than have been previously reported with ACET devices. ACET is very suitable for accurate actuation and control of fluid flow, since the technique has been shown to be very effective in high conductivity fluids and has the ability to create a pulsation free flow. However, AC electrokinetic pumps usually can only generate low operating pressures of 1 to 100 Pa, where flow reversal is likely to occur with an external load. In order to realize a high performance ACET micropump for continuous fluid delivery, applying relatively high AC operating voltages (20 to 36 Vrms) to silicon substrate ACET actuators and using long serpentine channel allows the boosting of operating pressure as well as increasing the flow rates. Fast pumping flow rates (102-103 nl/s) and high operating pressures (1-12 kPa) can be achieved by applying both methods, making them of significant importance for continuous fluid delivery applications using microneedle arrays and other such biomedical devices.

  11. Experimental and computational fluid dynamic studies of mixing for complex oral health products

    Science.gov (United States)

    Garcia, Marti Cortada; Mazzei, Luca; Angeli, Panagiota

    2015-11-01

    Mixing high viscous non-Newtonian fluids is common in the consumer health industry. Sometimes this process is empirical and involves many pilot plants trials which are product specific. The first step to study the mixing process is to build on knowledge on the rheology of the fluids involved. In this research a systematic approach is used to validate the rheology of two liquids: glycerol and a gel formed by polyethylene glycol and carbopol. Initially, the constitutive equation is determined which relates the viscosity of the fluids with temperature, shear rate, and concentration. The key variable for the validation is the power required for mixing, which can be obtained both from CFD and experimentally using a stirred tank and impeller of well-defined geometries at different impeller speeds. A good agreement between the two values indicates a successful validation of the rheology and allows the CFD model to be used for the study of mixing in the complex vessel geometries and increased sizes encountered during scale up.

  12. Interchangeable opening and closing clapper device notably for ventilation ducts utilizing an aggressive or polluting fluid

    International Nuclear Information System (INIS)

    1980-01-01

    This opening and closing device is of the type which employs a casing inside the duct along the fluid path. It is provided with an opening through which the fluid flows and a joint with a closing clapper controlled from the outside enabling the fluid flow to be regulated. It is characterized by the fact that the casing is provided with a lateral opening with respect to the fluid flow direction, the size of this opening being sufficiently large to allow the assembly with its closing clapper to be introduced and withdrawn [fr

  13. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    Science.gov (United States)

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  14. Prediction of bacterial meningitis based on cerebrospinal fluid pleocytosis in children

    Directory of Open Access Journals (Sweden)

    Sofia Águeda

    Full Text Available Children with cerebrospinal fluid pleocytosis are frequently treated with parenteral antibiotics, but only a few have bacterial meningitis. Although some clinical prediction rules, such as bacterial meningitis score, are of well-known value, the cerebrospinal fluid white blood cells count can be the initial available information. Our aim was to establish a cutoff point of cerebrospinal fluid white blood cell count that could distinguish bacterial from viral and aseptic meningitis. A retrospective study of children aged 29 days to 17 years who were admitted between January 1st and December 31th, 2009, with cerebrospinal fluid pleocytosis (white blood cell > 7 µL-1 was conducted. The cases of traumatic lumbar puncture and of antibiotic treatment before lumbar puncture were excluded. There were 295 patients with cerebrospinal fluid pleocytosis, 60.3% females, medium age 5.0 ± 4.3 years distributed as: 12.2% 1-3 months; 10.5% 3-12 months; 29.8% 12 months to 5 years; 47.5% >5 years. Thirty one children (10.5% were diagnosed with bacterial meningitis, 156 (52.9% viral meningitis and 108 (36.6% aseptic meningitis. Bacterial meningitis was caused by Neisseria meningi tidis (48.4%, Streptococcus pneumoniae (32.3%, other Streptococcus species (9.7%, and other agents (9.7%. cerebrospinal fluid white blood cell count was significantly higher in patients with bacterial meningitis (mean, 4839 cells/µL compared to patients with aseptic meningitis (mean, 159 cells/µL, p < 0.001, with those with aseptic meningitis (mean, 577 cells/µL, p < 0.001 and with all non-bacterial meningitis cases together (p < 0.001. A cutoff value of 321 white blood cell/µL showed the best combination of sensitivity (80.6% and specificity (81.4% for the diagnosis of bacterial meningitis (area under receiver operating characteristic curve 0.837. Therefore, the value of cerebrospinal fluid white blood cell count was found to be a useful and rapid diagnostic test to distinguish

  15. Structural and numerical modeling of fluid flow and evolving stress fields at a transtensional stepover: A Miocene Andean porphyry copper system as a case study.

    Science.gov (United States)

    Nuñez, R. C.; Griffith, W. A.; Mitchell, T. M.; Marquardt, C.; Iturrieta, P. C.; Cembrano, J. M.

    2017-12-01

    Obliquely convergent subduction orogens show both margin-parallel and margin-oblique fault systems that are spatially and temporally associated with ore deposits and geothermal systems within the volcanic arc. Fault orientation and mechanical interaction among different fault systems influence the stress field in these arrangements, thus playing a first order control on the regional to local-scale fluid migration paths as documented by the spatial distribution of fault-vein arrays. Our selected case study is a Miocene porphyry copper-type system that crops out in the precordillera of the Maule region along the Teno river Valley (ca. 35°S). Several regional to local faults were recognized in the field: (1) Two first-order, N-striking subvertical dextral faults overlapping at a right stepover; (2) Second-order, N60°E-striking steeply-dipping, dextral-normal faults located at the stepover, and (3) N40°-60°W striking subvertical, sinistral faults crossing the stepover zone. The regional and local scale geology is characterized by volcano-sedimentary rocks (Upper Eocene- Lower Miocene), intruded by Miocene granodioritic plutons (U-Pb zircon age of 18.2 ± 0.11 Ma) and coeval dikes. We implement a 2D boundary element displacement discontinuity method (BEM) model to test the mechanical feasibility of kinematic model of the structural development of the porphyry copper-type system in the stepover between N-striking faults. The model yields the stress field within the stepover region and shows slip and potential opening distribution along the N-striking master faults under a regionally imposed stress field. The model shows that σ1 rotates clockwise where the main faults approach each other, becoming EW when they overlap. This, in turn leads to the generation of both NE- and NW-striking faults within the stepover area. Model results are consistent with the structural and kinematic data collected in the field attesting for enhanced permeability and fluid flow transport

  16. Encephalitis treatment – a case report with long-term follow-up of EBV PCR in cerebrospinal fluid

    Directory of Open Access Journals (Sweden)

    Zarlasht F

    2017-10-01

    Full Text Available Fnu Zarlasht,1 Mashal Salehi,2 Mohammad Abu-Hishmeh,3 Muzammil Khan2 1Department of Medicine, Lourdes Hospital, Binghamton, NY, USA, 2Department of Medicine, NYC Health + Hospital/Harlem, Columbia University, NY, USA, 3Department of Medicine, Lincoln Medical and Mental Health Centre, Bronx NY, USA Background: Epstein–Barr virus (EBV has been found to cause infectious mononucleosis multiple times, but has been associated rarely with EBV encephalitis. Also, whenever it is diagnosed, it is always treated symptomatically.Case report: A case of confirmed EBV encephalitis is presented, which was treated with antiviral therapy resulting in complete clearance of the virus in cerebrospinal fluid and minimal neurologic symptoms after hospital discharge.Conclusion: The Infectious Diseases Society of America guidelines state that intravenous acyclovir is not recommended for EBV-related encephalitis. But we reviewed the literature and found similar cases, and we believe that antiviral therapy should be recommended for EBV encephalitis because it is a potentially fatal disease and if left untreated, can lead to raised intracranial pressure, craniotomy and even death. Keywords: Epstein–Barr virus, intravenous, human immune deficiency virus, HIV

  17. The magnetic fluid for heat transfer applications

    International Nuclear Information System (INIS)

    Nakatsuka, K.; Jeyadevan, B.; Neveu, S.; Koganezawa, H.

    2002-01-01

    Real-time visual observation of boiling water-based and ionic magnetic fluids (MFs) and heat transfer characteristics in heat pipe using ionic MF stabilized by citrate ions (JC-1) as working liquid are reported. Irrespective of the presence or absence of magnetic field water-based MF degraded during boiling. However, the degradation of JC-1 was avoided by heating the fluid in magnetic field. Furthermore, the heat transfer capacity of JC-1 heat pipe under applied magnetic field was enhanced over the no field case

  18. Analytical Solution of Electro-Osmotic Peristalsis of Fractional Jeffreys Fluid in a Micro-Channel

    Directory of Open Access Journals (Sweden)

    Xiaoyi Guo

    2017-11-01

    Full Text Available The electro-osmotic peristaltic flow of a viscoelastic fluid through a cylindrical micro-channel is studied in this paper. The fractional Jeffreys constitutive model, including the relaxation time and retardation time, is utilized to describe the viscoelasticity of the fluid. Under the assumptions of long wavelength, low Reynolds number, and Debye-Hückel linearization, the analytical solutions of pressure gradient, stream function and axial velocity are explored in terms of Mittag-Leffler function by Laplace transform method. The corresponding solutions of fractional Maxwell fluid and generalized second grade fluid are also obtained as special cases. The numerical analysis of the results are depicted graphically, and the effects of electro-osmotic parameter, external electric field, fractional parameters and viscoelastic parameters on the peristaltic flow are discussed.

  19. Effect of fluid friction on interstitial fluid flow coupled with blood flow through solid tumor microvascular network.

    Science.gov (United States)

    Sefidgar, Mostafa; Soltani, M; Raahemifar, Kaamran; Bazmara, Hossein

    2015-01-01

    A solid tumor is investigated as porous media for fluid flow simulation. Most of the studies use Darcy model for porous media. In Darcy model, the fluid friction is neglected and a few simplified assumptions are implemented. In this study, the effect of these assumptions is studied by considering Brinkman model. A multiscale mathematical method which calculates fluid flow to a solid tumor is used in this study to investigate how neglecting fluid friction affects the solid tumor simulation. The mathematical method involves processes such as blood flow through vessels and solute and fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. The sprouting angiogenesis model is used for generating capillary network and then fluid flow governing equations are implemented to calculate blood flow through the tumor-induced capillary network. Finally, the two models of porous media are used for modeling fluid flow in normal and tumor tissues in three different shapes of tumors. Simulations of interstitial fluid transport in a solid tumor demonstrate that the simplifications used in Darcy model affect the interstitial velocity and Brinkman model predicts a lower value for interstitial velocity than the values that Darcy model predicts.

  20. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  1. Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps

    Science.gov (United States)

    Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.

    2017-04-01

    Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.

  2. Extraperitoneal Fluid Collection due to Chronic Pancreatitis

    Directory of Open Access Journals (Sweden)

    Takeo Yasuda

    2013-08-01

    Full Text Available A 39-year-old man was referred to our hospital for the investigation of abdominal fluid collection. He was pointed out to have alcoholic chronic pancreatitis. Laboratory data showed inflammation and slightly elevated serum direct bilirubin and amylase. An abdominal computed tomography demonstrated huge fluid collection, multiple pancreatic pseudocysts and pancreatic calcification. The fluid showed a high level of amylase at 4,490 IU/l. Under the diagnosis of pancreatic ascites, endoscopic pancreatic stent insertion was attempted but was unsuccessful, so surgical treatment (Frey procedure and cystojejunostomy was performed. During the operation, a huge amount of fluid containing bile acid (amylase at 1,474 IU/l and bilirubin at 13.5 mg/dl was found to exist in the extraperitoneal space (over the peritoneum, but no ascites was found. His postoperative course was uneventful and he shows no recurrence of the fluid. Pancreatic ascites is thought to result from the disruption of the main pancreatic duct, the rupture of a pancreatic pseudocyst, or possibly leakage from an unknown site. In our extremely rare case, the pancreatic pseudocyst penetrated into the hepatoduodenal ligament with communication to the common bile duct, and the fluid flowed into the round ligament of the liver and next into the extraperitoneal space.

  3. Study of the pathway and the dynamics of cerebrospinal fluid by the administration of metrizamide

    International Nuclear Information System (INIS)

    Ueda, Yasuichi; Nagai, Masakatsu

    1979-01-01

    50 patients were submitted to the computerized tomographic study after the intrathecal administration of Metrizamide (Amipaque), those diagnoses were cerebrovascular disease, brain tumors, head injury, hydrocephalus, subdural hygroma, arachnoid cyst, and miscellaneous. The main purpose of the study was the examination of circulatory dynamics of the cerebrospinal fluid (Metrizamide CT cisternography). CT assisted ventriculography and CT assisted myelography were also performed in 5 cases. 6 ml of isotonic (170 mgI/ml) Metrizamide were administered through lumbar tap for adult cases and 3 ml for children. In the method of high cervical route, the large cistern and the basal cistern were enhanced a few minutes after injection. The dynamics of CSF then after revealed the same manner as the lumbar route. The advantages of the high cervical route were the fewer volume of the drug and the shorter period of the examination. In 22 cases, the findings of ventricular reflux were noted, 6 cases of which showed persistent ventricular filling. In 9 cases of ventricular reflux, the ''niveau formation'' was seen, which might be caused by the higher gravity of Metrizamide and it should be regarded as one of the important diagnostic evidences of normal pressure hydrocephalus. Metrizamide CT cisternography could be applied to the examination of communicability of the CSF in the arachnoid cyst or the subdural hygroma with subarachnoid space. For the diagnosis of the extension of juxtabasal tumors, Metrizamide CT cisternography was useful also. CT assisted ventriculography was also useful for the diagnosis of the shift of IVth ventricle compressed by the large cerebellar tumor. CT assisted myelography revealed diagnostic value for the spinal lesions. The side effects of Metrizamide such as headache, nausea and vomiting were minimal and temporary. (author)

  4. On the feasibility of inducing oil mobilization in existing reservoirs via wellbore harmonic fluid action

    KAUST Repository

    Jeong, Chanseok

    2011-03-01

    Although vibration-based mobilization of oil remaining in mature reservoirs is a promising low-cost method of enhanced oil recovery (EOR), research on its applicability at the reservoir scale is still at an early stage. In this paper, we use simplified models to study the potential for oil mobilization in homogeneous and fractured reservoirs, when harmonically oscillating fluids are injected/produced within a well. To this end, we investigate first whether waves, induced by fluid pressure oscillations at the well site, and propagating radially and away from the source in a homogeneous reservoir, could lead to oil droplet mobilization in the reservoir pore-space. We discuss both the fluid pore-pressure wave and the matrix elastic wave cases, as potential agents for increasing oil mobility. We then discuss the more realistic case of a fractured reservoir, where we study the fluid pore-pressure wave motion, while taking into account the leakage effect on the fracture wall. Numerical results show that, in homogeneous reservoirs, the rock-stress wave is a better energy-delivery agent than the fluid pore-pressure wave. However, neither the rock-stress wave nor the pore-pressure wave is likely to result in any significant residual oil mobilization at the reservoir scale. On the other hand, enhanced oil production from the fractured reservoir\\'s matrix zone, induced by cross-flow vibrations, appears to be feasible. In the fractured reservoir, the fluid pore-pressure wave is only weakly attenuated through the fractures, and thus could induce fluid exchange between the rock formation and the fracture space. The vibration-induced cross-flow is likely to improve the imbibition of water into the matrix zone and the expulsion of oil from it. © 2011 Elsevier B.V.

  5. Simulation based engineering in fluid flow design

    CERN Document Server

    Rao, J S

    2017-01-01

    This volume offers a tool for High Performance Computing (HPC). A brief historical background on the subject is first given. Fluid Statics dealing with Pressure in fluids at rest, Buoyancy and Basics of Thermodynamics are next presented. The Finite Volume Method, the most convenient process for HPC, is explained in one-dimensional approach to diffusion with convection and pressure velocity coupling. Adiabatic, isentropic and supersonic flows in quasi-one dimensional flows in axisymmetric nozzles is considered before applying CFD solutions. Though the theory is restricted to one-dimensional cases, three-dimensional CFD examples are also given. Lastly, nozzle flows with normal shocks are presented using turbulence models. Worked examples and exercises are given in each chapter. Fluids transport thermal energy for its conversion to kinetic energy, thus playing a major role that is central to all heat engines. With the advent of rotating machinery in the 20th century, Fluid Engineering was developed in the form o...

  6. Instrumentation, measurements, and experiments in fluids

    CERN Document Server

    Rathakrishnan, E

    2007-01-01

    NEED AND OBJECTIVE OF EXPERIMENTAL STUDY Some Fluid Mechanics MeasurementsMeasurement SystemsSome of the Important Quantities Associated with FluidFlow MeasurementsFUNDAMENTALS OF FLUID MECHANICSProperties of FluidsThermodynamic PropertiesSurface TensionAnalysis of Fluid FlowBasic and Subsidiary Laws for Continuous MediaKinematics of Fluid FlowStreamlinesPotential FlowViscous FlowsGas DynamicsWIND TUNNELSLow-Speed Wind TunnelsPower Losses in a Wind TunnelHigh-Speed Wind TunnelsHypersonic TunnelsInstrume

  7. Simulating coupled dynamics of a rigid-flexible multibody system and compressible fluid

    Science.gov (United States)

    Hu, Wei; Tian, Qiang; Hu, HaiYan

    2018-04-01

    As a subsequent work of previous studies of authors, a new parallel computation approach is proposed to simulate the coupled dynamics of a rigid-flexible multibody system and compressible fluid. In this approach, the smoothed particle hydrodynamics (SPH) method is used to model the compressible fluid, the natural coordinate formulation (NCF) and absolute nodal coordinate formulation (ANCF) are used to model the rigid and flexible bodies, respectively. In order to model the compressible fluid properly and efficiently via SPH method, three measures are taken as follows. The first is to use the Riemann solver to cope with the fluid compressibility, the second is to define virtual particles of SPH to model the dynamic interaction between the fluid and the multibody system, and the third is to impose the boundary conditions of periodical inflow and outflow to reduce the number of SPH particles involved in the computation process. Afterwards, a parallel computation strategy is proposed based on the graphics processing unit (GPU) to detect the neighboring SPH particles and to solve the dynamic equations of SPH particles in order to improve the computation efficiency. Meanwhile, the generalized-alpha algorithm is used to solve the dynamic equations of the multibody system. Finally, four case studies are given to validate the proposed parallel computation approach.

  8. Cerebrospinal fluid biomarker supported diagnosis of Creutzfeldt–Jakob disease and rapid dementias: a longitudinal multicentre study over 10 years

    Science.gov (United States)

    Sanchez-Juan, Pascual; Gawinecka, Joanna; Green, Alison; Ladogana, Anna; Pocchiari, Maurizio; Sanchez-Valle, Raquel; Mitrova, Eva; Sklaviadis, Theodor; Kulczycki, Jerzy; Slivarichova, Dana; Saiz, Albert; Calero, Miguel; Knight, Richard; Aguzzi, Adriano; Laplanche, Jean-Louis; Peoc’h, Katell; Schelzke, Gabi; Karch, Andre; van Duijn, Cornelia M.; Zerr, Inga

    2012-01-01

    To date, cerebrospinal fluid analysis, particularly protein 14-3-3 testing, presents an important approach in the identification of Creutzfeldt–Jakob disease cases. However, one special point of criticism of 14-3-3 testing is the specificity in the differential diagnosis of rapid dementia. The constant observation of increased cerebrospinal fluid referrals in the national surveillance centres over the last years raises the concern of declining specificity due to higher number of cerebrospinal fluid tests performed in various neurological conditions. Within the framework of a European Community supported longitudinal multicentre study (‘cerebrospinal fluid markers’) we analysed the spectrum of rapid progressive dementia diagnoses, their potential influence on 14-3-3 specificity as well as results of other dementia markers (tau, phosphorylated tau and amyloid-β1–42) and evaluated the specificity of 14-3-3 in Creutzfeldt–Jakob disease diagnosis for the years 1998–2008. A total of 29 022 cerebrospinal fluid samples were analysed for 14-3-3 protein and other cerebrospinal fluid dementia markers in patients with rapid dementia and suspected Creutzfeldt–Jakob disease in the participating centres. In 10 731 patients a definite diagnosis could be obtained. Protein 14-3-3 specificity was analysed for Creutzfeldt–Jakob disease with respect to increasing cerebrospinal fluid tests per year and spectrum of differential diagnosis. Ring trials were performed to ensure the comparability between centres during the reported time period. Protein 14-3-3 test specificity remained high and stable in the diagnosis of Creutzfeldt–Jakob disease during the observed time period across centres (total specificity 92%; when compared with patients with definite diagnoses only: specificity 90%). However, test specificity varied with respect to differential diagnosis. A high 14-3-3 specificity was obtained in differentiation to other neurodegenerative diseases (95–97%) and non

  9. Cerebrospinal fluid biomarker supported diagnosis of Creutzfeldt-Jakob disease and rapid dementias: a longitudinal multicentre study over 10 years.

    Science.gov (United States)

    Stoeck, Katharina; Sanchez-Juan, Pascual; Gawinecka, Joanna; Green, Alison; Ladogana, Anna; Pocchiari, Maurizio; Sanchez-Valle, Raquel; Mitrova, Eva; Sklaviadis, Theodor; Kulczycki, Jerzy; Slivarichova, Dana; Saiz, Albert; Calero, Miguel; Knight, Richard; Aguzzi, Adriano; Laplanche, Jean-Louis; Peoc'h, Katell; Schelzke, Gabi; Karch, Andre; van Duijn, Cornelia M; Zerr, Inga

    2012-10-01

    To date, cerebrospinal fluid analysis, particularly protein 14-3-3 testing, presents an important approach in the identification of Creutzfeldt-Jakob disease cases. However, one special point of criticism of 14-3-3 testing is the specificity in the differential diagnosis of rapid dementia. The constant observation of increased cerebrospinal fluid referrals in the national surveillance centres over the last years raises the concern of declining specificity due to higher number of cerebrospinal fluid tests performed in various neurological conditions. Within the framework of a European Community supported longitudinal multicentre study ('cerebrospinal fluid markers') we analysed the spectrum of rapid progressive dementia diagnoses, their potential influence on 14-3-3 specificity as well as results of other dementia markers (tau, phosphorylated tau and amyloid-β(1-42)) and evaluated the specificity of 14-3-3 in Creutzfeldt-Jakob disease diagnosis for the years 1998-2008. A total of 29 022 cerebrospinal fluid samples were analysed for 14-3-3 protein and other cerebrospinal fluid dementia markers in patients with rapid dementia and suspected Creutzfeldt-Jakob disease in the participating centres. In 10 731 patients a definite diagnosis could be obtained. Protein 14-3-3 specificity was analysed for Creutzfeldt-Jakob disease with respect to increasing cerebrospinal fluid tests per year and spectrum of differential diagnosis. Ring trials were performed to ensure the comparability between centres during the reported time period. Protein 14-3-3 test specificity remained high and stable in the diagnosis of Creutzfeldt-Jakob disease during the observed time period across centres (total specificity 92%; when compared with patients with definite diagnoses only: specificity 90%). However, test specificity varied with respect to differential diagnosis. A high 14-3-3 specificity was obtained in differentiation to other neurodegenerative diseases (95-97%) and non

  10. Computation of demagnetizing fields and particle distribution in magnetic fluid with inhomogeneous density

    International Nuclear Information System (INIS)

    Pshenichnikov, A.F.

    2012-01-01

    A new algorithm for calculating magnetic fields in a concentrated magnetic fluid with inhomogeneous density is proposed. Inhomogeneity of the fluid is caused by magnetophoresis. In this case, the diffusion and magnetostatic parts of the problem are tightly linked together and are solved jointly. The dynamic diffusion equation is solved by the finite volume method and, to calculate the magnetic field inside the fluid, an iterative process is performed in parallel. The solution to the problem is sought in Cartesian coordinates, and the computational domain is decomposed into rectangular elements. This technique eliminates the need to solve the related boundary-value problem for magnetic fields, accelerates computations and eliminates the error caused by the finite sizes of the outer region. Formulas describing the contribution of the rectangular element to the field intensity in the case of a plane problem are given. Magnetic and concentration fields inside the magnetic fluid filling a rectangular cavity generated under the action of the uniform external filed are calculated. - Highlights: ▶ New algorithm for calculating magnetic field intense magnetic fluid with account of magnetophoresis and diffusion of particles. ▶ We do not need to solve boundary-value problem, but we accelerate computations and eliminate some errors. ▶ We solve nonlinear flow equation by the finite volume method and calculate magnetic and focus fields in the fluid for plane case.

  11. The Swedish study of Irrigation-fluid temperature in the evacuation of Chronic subdural hematoma (SIC!)

    DEFF Research Database (Denmark)

    Bartley, Andreas; Jakola, Asgeir S; Bartek, Jiri

    2017-01-01

    BACKGROUND: Chronic subdural hematoma (cSDH) is one of the most common conditions encountered in neurosurgical practice. Recurrence, observed in 5-30% of patients, is a major clinical problem. The temperature of the irrigation fluid used during evacuation of the hematoma might theoretically...... and health-related quality of life. DISCUSSION: Irrigation-fluid temperature might influence recurrence rates in the evacuation of chronic subdural hematomas. We present a study protocol for a multicenter randomized controlled trial investigating our hypothesis that irrigation fluid at body temperature...

  12. DNA - An integrated open-source optimization platform for thermo-fluid systems

    DEFF Research Database (Denmark)

    Pierobon, Leonardo; Wronski, Jorrit; Elmegaard, Brian

    2014-01-01

    This paper presents developments and new features added to the simulation tool Dynamic Network Analysis. This open-source software is the result of ongoing development at the Department of Mechanical Engineering, Technical University of Denmark since 1988. Ever since, it has been employed to model...... to extend the capabilities of the software, while at the same time decreasing computational time. Dynamic Network Analysis can now solve non-convex optimization problems by virtue of the fully-embedded genetic algorithm. Moreover, the thermophysical fluid property library has been extended with more than...... 110 fluids by interfacing CoolProp, a high-accuracy open-source property package for pure and pseudo-pure fluids, as well as humid air. Furthermore, the use as time integrator for other tools is demonstrated. The new features are unveiled in two case studies. The first example covers the optimization...

  13. SOLA-VOF, 2-D Transient Hydrodynamic Using Fractional Volume of Fluid Method

    International Nuclear Information System (INIS)

    Nichols, B.D.; Hirt, C.W.; Hotchkiss, R.S.

    1991-01-01

    1 - Description of problem or function: SOLA-VOF is a program for the solution of two-dimensional transient fluid flow with free boundaries, based on the concept of a fractional volume of fluid (VOF). Its basic mode of operation is for single fluid calculations having multiple free surfaces. However, SOLA-VOF can also be used for calculations involving two fluids separated by a sharp interface. In either case, the fluids may be treated as incompressible or as having limited compressibility. Surface tension forces with wall adhesion are permitted in both cases. Internal obstacles may be defined by blocking out any desired combination of cells in the mesh, which is composed of rectangular cells of variable size. 2 - Method of solution: The basis of the SOLA-VOF method is the fractional volume of fluid scheme for tracking free boundaries. In this technique, a function F(x,y,t) is defined whose value is unity at any point occupied by fluid and zero elsewhere. When averaged over the cells of a computational mesh, the average value of F in a cell is equal to the fractional volume of the cell occupied by fluid. In particular, a unit value of F corresponds to a cell full of fluid, whereas a zero value indicates that the cell contains no fluid. Cells with F values between zero and one contain a free surface. SOLA-VOF uses an Eulerian mesh of rectangular cells having variable sizes. The fluid equations solved are the finite difference approximations of the Navier-Stokes equations. 3 - Restrictions on the complexity of the problem: The setting of array dimensions is controlled through PARAMETER statements

  14. Persistent dural cerebrospinal fluid leak shown by retrograde radionuclide myelography: case report

    International Nuclear Information System (INIS)

    Kadrie, H.; Driedger, A.A.; McInnis, W.

    1976-01-01

    Following inadvertent spinal anesthesia for delivery, a patient developed incapacitating post-lumbar puncture headache that persisted for 9 weeks. Scintigrams of the lumbar region, obtained after injection of /sup 99m/Tc-human serum albumin into the cisterna magna, showed the cerebrospinal fluid leak. Blood patch repair was carried out, with immediate relief of all symptoms. Because of subsequent atypical headaches, a second cisternogram was done by the same technique. This study confirmed that there was no further dural leak, and other evidence indicated that the recurrent headache was related to functional problems

  15. Circulation of cerebrospinal fluid. Comparative study of various tracers

    International Nuclear Information System (INIS)

    Bok, B.; Thebault, B.; Cavailloles, F.; Aboulker, J.

    1977-01-01

    The dynamics of cerebrospinal fluid in the spinal subarachnoid space is studied by gammamyelography. There are still controversies about the ideal properties of the tracer to be used. The influence of the tracer's molecular weight on the kinetic of ascent in the medullar cerebrospinal fluid with a view to rating the criterias for choice of an available radiopharmaceutical was evaluated. Three compounds injected simultaneously through a lombar puncture were compared: indium 111 labelled transferrin, iodine 131 labelled human serum albumin and technetium 99m labelled diethylenetriaminepentaacetic acid. The individual stability of the compounds and a possible interference between them was investigated especially by electrophoretic technics. A spectrometric study showed that it is possible to simultaneously identify and count each of the isotopes included in the mixture on the detector device: an hybrid scanner. The comparison of linear activity profils collected on phantoms and on ten patients showed a similar fate of the three compounds during the first hours of the investigation studying the ascent of tracers into basal cisterns either in normal or pathological patients. It is therefore concluded that molecular weight does not influence in a detectable manner the spinal C.S.F. kinetics of the radiopharmaceuticals. This allows the use of the most convenient and best tolerated tracer from the dosimetric and toxicological stand point [fr

  16. Subduction-like fluids in the genesis of Mt. Etna magmas: evidence from boron isotopes and fluid mobile elements

    Science.gov (United States)

    Tonarini, Sonia; Armienti, Pietro; D'Orazio, Massimo; Innocenti, Fabrizio

    2001-11-01

    New whole-rock B, Sr, Nd isotope ratios and 87Sr/ 86Sr on clinopyroxenes have been collected to study the enrichment of fluid mobile elements (FMEs) observed in Mt. Etna volcanics. Etna volcano, one of the most active in the world, is located in an extremely complex tectonic context at the boundary between colliding African and European plates. The analytical work focuses on current (1974-1998) and historic (1851-1971) eruptive activity, including some key prehistoric lavas, in order to interpret the secular shift of its geochemical signature to more alkaline compositions. Boron is used as a tool to unravel the role of fluids in the genesis of magmas, revealing far-reaching consequences, beyond the case study of Mt. Etna. Small variations are observed in δ 11B (-3.5 to -8.0‰), 87Sr/ 86Sr (0.70323-0.70370), and 143Nd/ 144Nd (0.51293-0.51287). Moreover, temporal evolution to higher δ 11B and 87Sr/ 86Sr, and to lower 143Nd/ 144Nd, is observed in the current activity, defining a regular trend. Sr isotopic equilibrium between whole-rock and clinopyroxene pairs indicates the successive introduction of three distinct magma types into the Etna plumbing system over time; these are characterized by differing degrees of FME enrichment. In addition, certain lavas exhibit evidence for country rock assimilation, magma-fluid interaction, or magma mixing in the shallow feeding system; at times these processes apparently lowered magmatic δ 11B and/or induced Sr isotopic disequilibrium between whole rock and clinopyroxene. The regular increase of δ 11B values is correlated with Nb/FME and 87Sr/ 86Sr ratios; these correlations are consistent with simple mixing between the mantle source and aqueous fluids derived from nearby Ionian slab. The best fit of Mt. Etna data is obtained using an enriched-MORB mantle source and a fluid phase with δ 11B of about -2‰ and 87Sr/ 86Sr of 0.708. We argue that the slab window generated by differential roll-back of subducting Ionian

  17. Modelling of heat transfer to fluids at a supercritical pressure

    International Nuclear Information System (INIS)

    Shuisheng, He

    2014-01-01

    A key feature of Supercritical Water-cooled Reactor (SCWR) is that, by raising the pressure of the reactor coolant fluid above the critical value, a phase change crisis is avoided. However, the changes in water density as it flows through the core of an SCWR are actually much higher than in the current water-cooled reactors. In a typical design, the ratio of the density of water at the core inlet to that at exit is as high as 7:1. Other fluid properties also vary significantly, especially around the pseudo-critical temperature (at which the specific heat capacity peaks). As a result, turbulent flow and heat transfer behaviour in the core is extremely complex and under certain conditions, significant heat transfer deterioration can potentially occur. Consequently, understanding and being able to predict flow and heat transfer phenomena under normal steady operation conditions and in start-up and hypothetical fault conditions are fundamental to the design of SCWR. There have been intensive studies on flow and heat transfer to fluids at supercritical pressure recently and several excellent review papers have been published. In the talk, we will focus on some turbulence modelling issues encountered in CFD simulations. The talk will first discuss some flow and heat transfer issues related to fluids at supercritical pressures and their potential implications in SCWR, and some recent developments in the understanding and modelling techniques of such problems, which will be followed by an outlook for some future developments.Factors which have a major influence on the flow and will be discussed are buoyancy and flow acceleration due to thermal expansion (both are due to density variations but involve different mechanisms) and the nonuniformity of other fluid properties. In addition, laminar-turbulent flow transition coupled with buoyancy and flow acceleration plays an important role in heat transfer effectiveness and wall temperature in the entrance region but such

  18. The irritancy of metalworking fluids: a laser Doppler flowmetry study

    NARCIS (Netherlands)

    de Boer, E. M.; Scholten, R. J.; van Ketel, W. G.; Bruynzeel, D. P.

    1990-01-01

    Irritant contact dermatitis is common in metalworkers exposed to metalworking fluids (MWF). The irritancy of 3 commercially available water-based cutting fluids in maximal user's concentration and 2 neat oils was investigated in 23 healthy volunteers. Additionally, the irritancy of some groups of

  19. Computational Fluid Dynamics for nuclear applications: from CFD to multi-scale CMFD

    International Nuclear Information System (INIS)

    Yadigaroglu, G.

    2005-01-01

    New trends in computational methods for nuclear reactor thermal-hydraulics are discussed; traditionally, these have been based on the two-fluid model. Although CFD computations for single phase flows are commonplace, Computational Multi-Fluid Dynamics (CMFD) is still under development. One-fluid methods coupled with interface tracking techniques provide interesting opportunities and enlarge the scope of problems that can be solved. For certain problems, one may have to conduct 'cascades' of computations at increasingly finer scales to resolve all issues. The case study of condensation of steam/air mixtures injected from a downward-facing vent into a pool of water and a proposed CMFD initiative to numerically model Critical Heat Flux (CHF) illustrate such cascades. For the venting problem, a variety of tools are used: a system code for system behaviour; an interface-tracking method (Volume of Fluid, VOF) to examine the behaviour of large bubbles; direct-contact condensation can be treated either by Direct Numerical Simulation (DNS) or by analytical methods

  20. Computational Fluid Dynamics for nuclear applications: from CFD to multi-scale CMFD

    Energy Technology Data Exchange (ETDEWEB)

    Yadigaroglu, G. [Swiss Federal Institute of Technology-Zurich (ETHZ), Nuclear Engineering Laboratory, ETH-Zentrum, CLT CH-8092 Zurich (Switzerland)]. E-mail: yadi@ethz.ch

    2005-02-01

    New trends in computational methods for nuclear reactor thermal-hydraulics are discussed; traditionally, these have been based on the two-fluid model. Although CFD computations for single phase flows are commonplace, Computational Multi-Fluid Dynamics (CMFD) is still under development. One-fluid methods coupled with interface tracking techniques provide interesting opportunities and enlarge the scope of problems that can be solved. For certain problems, one may have to conduct 'cascades' of computations at increasingly finer scales to resolve all issues. The case study of condensation of steam/air mixtures injected from a downward-facing vent into a pool of water and a proposed CMFD initiative to numerically model Critical Heat Flux (CHF) illustrate such cascades. For the venting problem, a variety of tools are used: a system code for system behaviour; an interface-tracking method (Volume of Fluid, VOF) to examine the behaviour of large bubbles; direct-contact condensation can be treated either by Direct Numerical Simulation (DNS) or by analytical methods.

  1. Generalized added masses computation for fluid structure interaction

    International Nuclear Information System (INIS)

    Lazzeri, L.; Cecconi, S.; Scala, M.

    1983-01-01

    The aim of this paper a description of a method to simulate the dynamic effect of a fluid between two structures by means of an added mass and an added stiffness. The method is based on a potential theory which assumes the fluid is inviscid and incompressible (the case of compressibility is discussed); a solution of the corresponding field equation is given as a superposition of elementary conditions (i.e. applicable to elementary boundary conditions). Consequently the pressure and displacements of the fluid on the boundary are given as a function of the series coefficients; the ''work lost'' (i.e. the work done by the pressures on the difference between actual and estimated displacements) is minimized, in this way the expansion coefficients are related to the displacements on the boundaries. Virtual work procedures are then used to compute added masses. The particular case of a free surface (with gravity effects) is discussed, it is shown how the effect can be modelled by means of an added stiffness term. Some examples relative to vibrations in reservoirs are given and discussed. (orig.)

  2. Working fluid selection for organic Rankine cycles - Impact of uncertainty of fluid properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Andreasen, Jesper Graa; Liu, Wei

    2016-01-01

    This study presents a generic methodology to select working fluids for ORC (Organic Rankine Cycles)taking into account property uncertainties of the working fluids. A Monte Carlo procedure is described as a tool to propagate the influence of the input uncertainty of the fluid parameters on the ORC...... modeloutput, and provides the 95%-confidence interval of the net power output with respect to the fluid property uncertainties. The methodology has been applied to a molecular design problem for an ORCusing a low-temperature heat source and consisted of the following four parts: 1) formulation...... of processmodels and constraints 2) selection of property models, i.e. Penge Robinson equation of state 3)screening of 1965 possible working fluid candidates including identification of optimal process parametersbased on Monte Carlo sampling 4) propagating uncertainty of fluid parameters to the ORC netpower output...

  3. Two-phase cooling fluids; Les fluides frigoporteurs diphasiques

    Energy Technology Data Exchange (ETDEWEB)

    Lallemand, A. [Institut National des Sciences Appliquees (INSA), 69 - Lyon (France)

    1997-12-31

    In the framework of the diminution of heat transfer fluid consumption, the concept of indirect refrigerating circuits, using cooling intermediate fluids, is reviewed and the fluids that are currently used in these systems are described. Two-phase cooling fluids advantages over single-phase fluids are presented with their thermophysical characteristics: solid fraction, two-phase mixture enthalpy, thermal and rheological properties, determination of heat and mass transfer characteristics, and cold storage through ice slurry

  4. Modeling Studies to Constrain Fluid and Gas Migration Associated with Hydraulic Fracturing Operations

    Science.gov (United States)

    Rajaram, H.; Birdsell, D.; Lackey, G.; Karra, S.; Viswanathan, H. S.; Dempsey, D.

    2015-12-01

    The dramatic increase in the extraction of unconventional oil and gas resources using horizontal wells and hydraulic fracturing (fracking) technologies has raised concerns about potential environmental impacts. Large volumes of hydraulic fracturing fluids are injected during fracking. Incidents of stray gas occurrence in shallow aquifers overlying shale gas reservoirs have been reported; whether these are in any way related to fracking continues to be debated. Computational models serve as useful tools for evaluating potential environmental impacts. We present modeling studies of hydraulic fracturing fluid and gas migration during the various stages of well operation, production, and subsequent plugging. The fluid migration models account for overpressure in the gas reservoir, density contrast between injected fluids and brine, imbibition into partially saturated shale, and well operations. Our results highlight the importance of representing the different stages of well operation consistently. Most importantly, well suction and imbibition both play a significant role in limiting upward migration of injected fluids, even in the presence of permeable connecting pathways. In an overall assessment, our fluid migration simulations suggest very low risk to groundwater aquifers when the vertical separation from a shale gas reservoir is of the order of 1000' or more. Multi-phase models of gas migration were developed to couple flow and transport in compromised wellbores and subsurface formations. These models are useful for evaluating both short-term and long-term scenarios of stray methane release. We present simulation results to evaluate mechanisms controlling stray gas migration, and explore relationships between bradenhead pressures and the likelihood of methane release and transport.

  5. Stress assessment in piping under synthetic thermal loads emulating turbulent fluid mixing

    Energy Technology Data Exchange (ETDEWEB)

    Costa Garrido, Oriol, E-mail: oriol.costa@ijs.si; El Shawish, Samir, E-mail: samir.elshawish@ijs.si; Cizelj, Leon, E-mail: leon.cizelj@ijs.si

    2015-03-15

    Highlights: • Generation of complex space-continuous and time-dependent temperature fields. • 1D and 3D thermo-mechanical analyses of pipes under complex surface thermal loads. • Surface temperatures and stress fluctuations are highly linearly correlated. • 1D and 3D results agree for a wide range of Fourier and Biot numbers. • Global thermo-mechanical loading promotes non-equibiaxial stress state. - Abstract: Thermal fatigue assessment of pipes due to turbulent fluid mixing in T-junctions is a rather difficult task because of the existing uncertainties and variability of induced thermal stresses. In these cases, thermal stresses arise on three-dimensional pipe structures due to complex thermal loads, known as thermal striping, acting at the fluid-wall interface. A recently developed approach for the generation of space-continuous and time-dependent temperature fields has been employed in this paper to reproduce fluid temperature fields of a case study from the literature. The paper aims to deliver a detailed study of the three-dimensional structural response of piping under the complex thermal loads arising in fluid mixing in T-junctions. Results of three-dimensional thermo-mechanical analyses show that fluctuations of surface temperatures and stresses are highly linearly correlated. Also, surface stress fluctuations, in axial and hoop directions, are almost equi-biaxial. These findings, representative on cross sections away from system boundaries, are moreover supported by the sensitivity analysis of Fourier and Biot numbers and by the comparison with standard one-dimensional analyses. Agreement between one- and three-dimensional results is found for a wide range of studied parameters. The study also comprises the effects of global thermo-mechanical loading on the surface stress state. Implemented mechanical boundary conditions develop more realistic overall system deformation and promote non-equibiaxial stresses.

  6. An equivalent fluid/equivalent medium approach for the numerical simulation of coastal landslides propagation: theory and case studies

    OpenAIRE

    P. Mazzanti; F. Bozzano

    2009-01-01

    Coastal and subaqueous landslides can be very dangerous phenomena since they are characterised by the additional risk of induced tsunamis, unlike their completely-subaerial counterparts. Numerical modelling of landslides propagation is a key step in forecasting the consequences of landslides. In this paper, a novel approach named Equivalent Fluid/Equivalent Medium (EFEM) has been developed. It adapts common numerical models and software that were originally designed for subaerial landslides i...

  7. A study of organic working fluids of an organic Rankine cycle for solar concentrating power plant

    International Nuclear Information System (INIS)

    Saifaoui, D.; Elmaanaoui, Y.; Faik, A.

    2014-01-01

    This work is a comparative study between four different configurations of an organic Rankine cycle (ORC) in order to find the configuration that gives the best performances. This study also made a comparison between seven organic fluids used as working fluids in the four ORC configurations. These fluids are all hydrocarbons. Then we made a parametric analysis of the results obtained in this first part. In a second part, we developed the binary mixtures of the seven pure hydrocarbons with the NIST software REFPROP 9 and we used them in our four ORC configurations. The obtained results are given and discussed. (author)

  8. Richtmyer–Meshkov instability of a thermal interface in a two-fluid plasma

    KAUST Repository

    Bond, D.

    2017-11-03

    We computationally investigate the Richtmyer–Meshkov instability of a density interface with a single-mode perturbation in a two-fluid, ion–electron plasma with no initial magnetic field. Self-generated magnetic fields arise subsequently. We study the case where the density jump across the initial interface is due to a thermal discontinuity, and select plasma parameters for which two-fluid plasma effects are expected to be significant in order to elucidate how they alter the instability. The instability is driven via a Riemann problem generated precursor electron shock that impacts the density interface ahead of the ion shock. The resultant charge separation and motion generates electromagnetic fields that cause the electron shock to degenerate and periodically accelerate the electron and ion interfaces, driving Rayleigh–Taylor instability. This generates small-scale structures and substantially increases interfacial growth over the hydrodynamic case.

  9. Control of pile power by measurement of the activity of the cooling fluid. The particular case of EL3

    International Nuclear Information System (INIS)

    Lalere, J.

    1959-01-01

    In a high flux pile the presence of local absorbers makes the power difficult to measure. In any case thermodynamic measurements are sometimes not very accurate. Another possible method could be the measurement of the cooling fluid activity. This has been tried on the heavy water circuit of EL3. In the first part of this report we give some qualitative indications of the various activities present in the heavy water in circulation. After this, the activity of the element chosen has been calculated. Finally, the results obtained from EL3 are given. (author) [fr

  10. A homogenization method for the analysis of a coupled fluid-structure interaction problem with inner solid structure

    International Nuclear Information System (INIS)

    Sigrist, Jean-Francois; Laine, Christian; Broc, Daniel

    2006-01-01

    The present paper exposes a homogenization method developed in order to perform the seismic analysis of a nuclear reactor with internal structures modelling and taking fluid structure interaction effects into account. The numerical resolution of fluid-structure interactions has made tremendous progress over the past decades and some applications of the various developed techniques in the industrial field can be found in the literature. As builder of nuclear naval propulsion reactors (ground prototype reactor or embarked reactor on submarines), DCN Propulsion has been working with French nuclear committee CEA for several years in order to integrate fluid-structure analysis in the design stage of current projects. In previous papers modal and seismic analyses of a nuclear reactor with fluid-structure interaction effect were exposed. The studies highlighted the importance of fluid- structure coupling phenomena in the industrial case and focussed on added mass and added stiffness effects. The numerical model used in the previous studies did not take into account the presence of internal structures within the pressure vessel. The present study aims at improving the numerical model of the nuclear reactor to take into account the presence of the internal structures. As the internal structures are periodical within the inner and outer structure of the pressure vessel the proposed model is based on the development of a homogenization method: the presence of internal structure and its effect on the fluid-structure physical interaction is taken into account, although they are not geometrically modeled. The basic theory of the proposed homogenization method is recalled, leading to the modification of fluid-structure coupling operator in the finite element model. The physical consistency of the method is proved by an evaluation of the system mass with the various mass operators (structure, fluid and fluid-structure operators). The method is exposed and validated in a 2 D case

  11. Fluid dynamics computer programs for NERVA turbopump

    Science.gov (United States)

    Brunner, J. J.

    1972-01-01

    During the design of the NERVA turbopump, numerous computer programs were developed for the analyses of fluid dynamic problems within the machine. Program descriptions, example cases, users instructions, and listings for the majority of these programs are presented.

  12. Viscous Flow with Large Fluid-Fluid Interface Displacement

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole; Saasen, Arild

    1998-01-01

    The arbitrary Lagrange-Euler (ALE) kinematic description has been implemented in a 3D transient finite element program to simulate multiple fluid flows with fluid-fluid interface or surface displacements. The description of fluid interfaces includes variable interfacial tension, and the formulation...... is useful in the simulation of low and intermediate Reynolds number viscous flow. The displacement of two immiscible Newtonian fluids in a vertical (concentric and eccentric) annulus and a (vertical and inclined)tube is simulated....

  13. The fluid inclusion study in petroleum exploration; O estudo de inclusoes fluidas na exploracao de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Carlos Eduardo Silva [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Gerencia da Geoquimica]. E-mail: cescoelho@petrobras.com.br

    2005-05-01

    Several oil companies and research centers have been studying petroleum fluid inclusions in reservoirs since the 1980's. The first works have used the fluid inclusion microthermometry technique in order to interpret the thermal history and petroleum migration in relation to the burial history and diagenesis. Lately, the micro thermometric data is being used as a calibration parameter for thermal history modeling in sedimentary basins and reservoirs. Recently, new fluid inclusion study techniques are being used in petroleum exploration. Geochemical data of low molecular weight (up to C{sub 15}) oil-bearing fluid inclusions has been used with the purpose of pinpointing oil-bearing intervals in wells that have not revealed the presence of oil by conventional techniques. Molecular geochemical analyses of oils inside the inclusions technique enable oil-source correlations, oil-oil correlations, and maturity determination. (author)

  14. Using Significant Geologic Hazards and Disasters to Focus Geoethics Case Studies

    Science.gov (United States)

    Cronin, V. S.

    2015-12-01

    coastlines, subsidence caused by fluid/gas withdrawal, induced seismicity, and pollution due to extractive industries. Case study sources are available via http://CroninProjects.org/Vince/GeoEthics/ and SERC has a growing collection of useful case studies (e.g., http://serc.carleton.edu/geoethics/case_studies.html).

  15. Influence of Non-linear Radiation Heat Flux on Rotating Maxwell Fluid over a Deformable Surface: A Numerical Study

    Science.gov (United States)

    Mustafa, M.; Mushtaq, A.; Hayat, T.; Alsaedi, A.

    2018-04-01

    Mathematical model for Maxwell fluid flow in rotating frame induced by an isothermal stretching wall is explored numerically. Scale analysis based boundary layer approximations are applied to simplify the conservation relations which are later converted to similar forms via appropriate substitutions. A numerical approach is utilized to derive similarity solutions for broad range of Deborah number. The results predict that velocity distributions are inversely proportional to the stress relaxation time. This outcome is different from that observed for the elastic parameter of second grade fluid. Unlike non-rotating frame, the solution curves are oscillatory decaying functions of similarity variable. As angular velocity enlarges, temperature rises and significant drop in the heat transfer coefficient occurs. We note that the wall slope of temperature has an asymptotically decaying profile against the wall to ambient ratio parameter. From the qualitative view point, temperature ratio parameter and radiation parameter have similar effect on the thermal boundary layer. Furthermore, radiation parameter has a definite role in improving the cooling process of the stretching boundary. A comparative study of current numerical computations and those from the existing studies is also presented in a limiting case. To our knowledge, the phenomenon of non-linear radiation in rotating viscoelastic flow due to linearly stretched plate is just modeled here.

  16. Stability of stationary solutions for inflow problem on the micropolar fluid model

    Science.gov (United States)

    Yin, Haiyan

    2017-04-01

    In this paper, we study the asymptotic behavior of solutions to the initial boundary value problem for the micropolar fluid model in a half-line R+:=(0,∞). We prove that the corresponding stationary solutions of the small amplitude to the inflow problem for the micropolar fluid model are time asymptotically stable under small H1 perturbations in both the subsonic and degenerate cases. The microrotation velocity brings us some additional troubles compared with Navier-Stokes equations in the absence of the microrotation velocity. The proof of asymptotic stability is based on the basic energy method.

  17. Effects of Intraoperative Fluid Management on Postoperative Outcomes : A Hospital Registry Study

    NARCIS (Netherlands)

    Shin, Christina H; Long, Dustin R; McLean, Duncan; Grabitz, Stephanie D; Ladha, Karim; Timm, Fanny P; Thevathasan, Tharusan; Pieretti, Alberto; Ferrone, Cristina; Hoeft, Andreas; Scheeren, Thomas W L; Thompson, Boyd Taylor; Kurth, Tobias; Eikermann, Matthias

    2017-01-01

    OBJECTIVE: Evaluate the dose-response relationship between intraoperative fluid administration and postoperative outcomes in a large cohort of surgical patients. BACKGROUND: Healthy humans may live in a state of fluid responsiveness without the need for fluid supplementation. Goal-directed protocols

  18. Effect of maternal intravenous fluid therapy on external cephalic version at term: a prospective cohort study.

    Science.gov (United States)

    Burgos, Jorge; Quintana, Eider; Cobos, Patricia; Osuna, Carmen; Centeno, María del Mar; Melchor, Juan Carlos

    2014-12-01

    We sought to analyze whether maternal intravenous fluid therapy prior to external cephalic version (ECV) increases the amount of amniotic fluid and the success rate of the procedure. This was a prospective single-center cohort study of 200 women with a consecutive cohort of 100 pregnant women with a breech presentation at term who were administered intravenous fluid therapy with 2 L of hypotonic saline before the version attempt, compared to a control cohort of 100 pregnant women not given hydration treatment. The mean increase in the amniotic fluid index (AFI) after intravenous maternal hydration was 3.75 ± 2.71 cm. The amount of fluid before hydration was the only variable found to be associated with increases in amniotic fluid levels, both in absolute and relative terms (odds ratio, -0.21; 95% confidence interval, -0.37 to -0.05 and odds ratio, -4.62; 95% confidence interval, -6.17 to -3.06; P < .01, respectively). We did not observe any severe complications secondary to the intravenous fluid therapy. The ECV success rate was 43% in the study group compared to 47% in the control group (P = .67). The success rate was significantly lower the larger the relative increase in the AFI, although no correlation was found in absolute terms (χ(2) for linear trend = 0.03 and 0.34, respectively). Maternal intravenous fluid therapy with 2 L of hypotonic saline prior to ECV is an effective and safe technique for increasing the AFI. However, its use in ECV does not increase the success rate of the procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. A STUDY ON THE PROPERTIES OF SURFACE – ACTIVE FLUIDS USED IN BURNISHING AND SHOT PEENING PROCESSES

    OpenAIRE

    Kazmierz Zaleski

    2016-01-01

    A method is presented for the study of surface-active properties of a fluids, in burnishing and shot peening processes used, which consists in comparing mean plastic strains of thin metal foil subjected to tensile tests in the examined fluid and in air. As a surface-active additive to the fluid (mineral oil), methyl polymethacrylate solution was used. It was found that the surfactant activity coefficient depended on the type of examined fluid as well as on the thickness of the foil being stre...

  20. Proteomic Analysis of Early Mid-Trimester Amniotic Fluid Does Not Predict Spontaneous Preterm Delivery

    Science.gov (United States)

    Lenco, Juraj; Vajrychova, Marie; Link, Marek; Tambor, Vojtech; Liman, Victor; Bullarbo, Maria; Nilsson, Staffan; Tsiartas, Panagiotis; Cobo, Teresa; Kacerovsky, Marian; Jacobsson, Bo

    2016-01-01

    Objective The aim of this study was to identify early proteomic biomarkers of spontaneous preterm delivery (PTD) in mid-trimester amniotic fluid from asymptomatic women. Methods This is a case-cohort study. Amniotic fluid from mid-trimester genetic amniocentesis (14–19 weeks of gestation) was collected from 2008 to 2011. The analysis was conducted in 24 healthy women with subsequent spontaneous PTD (cases) and 40 randomly selected healthy women delivering at term (controls). An exploratory phase with proteomics analysis of pooled samples was followed by a verification phase with ELISA of individual case and control samples. Results The median (interquartile range (IQR: 25th; 75th percentiles) gestational age at delivery was 35+5 (33+6–36+6) weeks in women with spontaneous PTD and 40+0 (39+1–40+5) weeks in women who delivered at term. In the exploratory phase, the most pronounced differences were found in C-reactive protein (CRP) levels, that were approximately two-fold higher in the pooled case samples than in the pooled control samples. However, we could not verify these differences with ELISA. The median (25th; 75th IQR) CRP level was 95.2 ng/mL (64.3; 163.5) in women with spontaneous PTD and 86.0 ng/mL (51.2; 145.8) in women delivering at term (p = 0.37; t-test). Conclusions Proteomic analysis with mass spectrometry of mid-trimester amniotic fluid suggests CRP as a potential marker of spontaneous preterm delivery, but this prognostic potential was not verified with ELISA. PMID:27214132

  1. Study of the hard-disk system at high densities: the fluid-hexatic phase transition.

    Science.gov (United States)

    Mier-Y-Terán, Luis; Machorro-Martínez, Brian Ignacio; Chapela, Gustavo A; Del Río, Fernando

    2018-06-21

    Integral equations of uniform fluids have been considered unable to predict any characteristic feature of the fluid-solid phase transition, including the shoulder that arises in the second peak of the fluid-phase radial distribution function, RDF, of hard-core systems obtained by computer simulations, at fluid densities very close to the structural two-step phase transition. This reasoning is based on the results of traditional integral approximations, like Percus-Yevick, PY, which does not show such a shoulder in hard-core systems, neither in two nor three dimensions. In this work, we present results of three Ansätze, based on the PY theory, that were proposed to remedy the lack of PY analytical solutions in two dimensions. This comparative study shows that one of those Ansätze does develop a shoulder in the second peak of the RDF at densities very close to the phase transition, qualitatively describing this feature. Since the shoulder grows into a peak at still higher densities, this integral equation approach predicts the appearance of an orientational order characteristic of the hexatic phase in a continuous fluid-hexatic phase transition.

  2. Fluid transport due to nonlinear fluid-structure interaction

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard

    1997-01-01

    This work considers nonlinear fluid-structure interaction for a vibrating pipe containing fluid. Transverse pipe vibrations will force the fluid to move relative to the pipe creating unidirectional fluid flow towards the pipe end. The fluid flow induced affects the damping and the stiffness...... of the pipe. The behavior of the system in response to lateral resonant base excitation is analysed numerically and by the use of a perturbation method (multiple scales). Exciting the pipe in the fundamental mode of vibration seems to be most effective for transferring energy from the shaker to the fluid......, whereas higher modes of vibration can be used to transport fluid with pipe vibrations of smaller amplitude. The effect of the nonlinear geometrical terms is analysed and these terms are shown to affect the response for higher modes of vibration. Experimental investigations show good agreement...

  3. Regularity criteria for the 3D magneto-micropolar fluid equations via ...

    Indian Academy of Sciences (India)

    3D magneto-micropolar fluid equations. It involves only the direction of the velocity and the magnetic field. Our result extends to the cases of Navier–Stokes and MHD equations. Keywords. Magneto-micropolar fluid equations; regularity criteria; direction of velocity. 2010 Mathematics Subject Classification. 35Q35, 76W05 ...

  4. Reduction of pasteurization temperature leads to lower bacterial outgrowth in pasteurized fluid milk during refrigerated storage: a case study.

    Science.gov (United States)

    Martin, N H; Ranieri, M L; Wiedmann, M; Boor, K J

    2012-01-01

    Bacterial numbers over refrigerated shelf-life were enumerated in high-temperature, short-time (HTST) commercially pasteurized fluid milk for 15 mo before and 15 mo after reducing pasteurization temperature from 79.4°C (175°F) [corrected] to 76.1°C (169°F). Total bacterial counts were measured in whole fat, 2% fat, and fat-free milk products on the day of processing as well as throughout refrigerated storage (6°C) at 7, 14, and 21 d postprocessing. Mean total bacterial counts were significantly lower immediately after processing as well as at 21 d postprocessing in samples pasteurized at 76.1°C versus samples pasteurized at 79.4°C. In addition to mean total bacterial counts, changes in bacterial numbers over time (i.e., bacterial growth) were analyzed and were lower during refrigerated storage of products pasteurized at the lower temperature. Lowering the pasteurization temperature for unflavored fluid milk processed in a commercial processing facility significantly reduced bacterial growth during refrigerated storage. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Supercritical fluid extraction: spectroscopic study of interactions comparison to solvent extraction

    Energy Technology Data Exchange (ETDEWEB)

    Rustenholtz Farawila, A

    2005-06-15

    Supercritical fluid carbon dioxide (SF-CO{sub 2}) was chosen to study Supercritical Fluid Extraction (SFE) of cesium and uranium. At first, crown ethers were considered as chelating agents for the SFE of cesium. The role of water and its interaction with crown ethers were especially studied using Fourier-Transform Infra-Red (FT-IR) spectroscopy in SF-CO{sub 2}. A sandwich configuration between two crown ethers and a water molecule was observed in the SF-CO{sub 2} phase for the first time. The equilibrium between the single and the bridge configurations was defined. The enthalpy of the hydrogen bond formation was also calculated. These results were then compared to the one in different mixtures of chloroform and carbon tetra-chloride using Nuclear Magnetic Resonance (NMR). To conclude this first part and in order to understand the whole picture of the recovery of cesium, I studied the role of water in the equilibrium between the cesium and the di-cyclo-hexano18-crown-6.In a second part, the supercritical fluid extraction of uranium was studied in SF-CO{sub 2}. For this purpose, different complexes of Tributyl Phosphate (TBP), nitric acid and water were used as chelating and oxidizing agents. I first used FT-IR to study the TBP-water interaction in SF-CO{sub 2}. These results were then compared to the one obtained with NMR in chloroform. NMR spectroscopy was also used to understand the TBP-nitric acid-water interaction first alone and then in chloroform. To conclude my research work, I succeeded to improve the efficiency of uranium extraction and stripping into water for a pilot-plant where enriched uranium is extracted from incinerated waste coming from nuclear fuel fabrication. TBP-nitric acid complexes were used in SF-CO{sub 2} for the extraction of uranium from ash. (author)

  6. Supercritical fluid extraction: spectroscopic study of interactions comparison to solvent extraction

    International Nuclear Information System (INIS)

    Rustenholtz Farawila, A.

    2005-06-01

    Supercritical fluid carbon dioxide (SF-CO 2 ) was chosen to study Supercritical Fluid Extraction (SFE) of cesium and uranium. At first, crown ethers were considered as chelating agents for the SFE of cesium. The role of water and its interaction with crown ethers were especially studied using Fourier-Transform Infra-Red (FT-IR) spectroscopy in SF-CO 2 . A sandwich configuration between two crown ethers and a water molecule was observed in the SF-CO 2 phase for the first time. The equilibrium between the single and the bridge configurations was defined. The enthalpy of the hydrogen bond formation was also calculated. These results were then compared to the one in different mixtures of chloroform and carbon tetra-chloride using Nuclear Magnetic Resonance (NMR). To conclude this first part and in order to understand the whole picture of the recovery of cesium, I studied the role of water in the equilibrium between the cesium and the di-cyclo-hexano18-crown-6.In a second part, the supercritical fluid extraction of uranium was studied in SF-CO 2 . For this purpose, different complexes of Tributyl Phosphate (TBP), nitric acid and water were used as chelating and oxidizing agents. I first used FT-IR to study the TBP-water interaction in SF-CO 2 . These results were then compared to the one obtained with NMR in chloroform. NMR spectroscopy was also used to understand the TBP-nitric acid-water interaction first alone and then in chloroform. To conclude my research work, I succeeded to improve the efficiency of uranium extraction and stripping into water for a pilot-plant where enriched uranium is extracted from incinerated waste coming from nuclear fuel fabrication. TBP-nitric acid complexes were used in SF-CO 2 for the extraction of uranium from ash. (author)

  7. Self-study manual for introduction to computational fluid dynamics

    OpenAIRE

    Nabatov, Andrey

    2017-01-01

    Computational Fluid Dynamics (CFD) is the branch of Fluid Mechanics and Computational Physics that plays a decent role in modern Mechanical Engineering Design process due to such advantages as relatively low cost of simulation comparing with conduction of real experiment, an opportunity to easily correct the design of a prototype prior to manufacturing of the final product and a wide range of application: mixing, acoustics, cooling and aerodynamics. This makes CFD particularly and Computation...

  8. A case of acute meningitis with clear cerebrospinal fluid: value of computed tomography for the diagnosis of central nervous system tuberculosis

    International Nuclear Information System (INIS)

    Cesari, V.

    1986-01-01

    The author reports a case of acute meningitis with clear cerebrospinal fluid in which extensive bacteriologic investigations were negative making the etiologic diagnosis exceedingly difficult. Initiation of empiric antituberculous therapy was rapidly followed by clinical and biological improvement, without complications, and by resolution of abnormal findings on computed tomography of the brain. On these grounds, meningitis secondary to a tuberculoma in the temporal lobe was diagnosed. The author points out that tuberculous meningitis is still a severe, potentially fatal condition; this, together with the fact that tubercle bacilli are often very scarce or absent, requires that tuberculous meningitis be routinely considered in every patient with clear cerebrospinal fluid meningitis whose condition deteriorates. Computed tomography of the brain is essential to ensure rapid diagnosis and prompt initiation of antituberculous therapy. Lastly, the author points out that nowadays herpes simplex virus encephalopathy should also be considered [fr

  9. Computational modelling of the flow of viscous fluids in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Khosravian, N [Computational Physical Sciences Research Laboratory, Department of Nano-Science, Institute for Research in Fundamental Sciences (IPM), PO Box 19395-5531, Tehran (Iran, Islamic Republic of); Rafii-Tabar, H [Computational Physical Sciences Research Laboratory, Department of Nano-Science, Institute for Research in Fundamental Sciences (IPM), PO Box 19395-5531, Tehran (Iran, Islamic Republic of)

    2007-11-21

    Carbon nanotubes will have extensive application in all areas of nano-technology, and in particular in the field of nano-fluidics, wherein they can be used for molecular separation, nano-scale filtering and as nano-pipes for conveying fluids. In the field of nano-medicine, nanotubes can be functionalized with various types of receptors to act as bio-sensors for the detection and elimination of cancer cells, or be used as bypasses and even neural connections. Modelling fluid flow inside nanotubes is a very challenging problem, since there is a complex interplay between the motion of the fluid and the stability of the walls. A critical issue in the design of nano-fluidic devices is the induced vibration of the walls, due to the fluid flow, which can promote structural instability. It has been established that the resonant frequencies depend on the flow velocity. We have studied, for the first time, the flow of viscous fluids through multi-walled carbon nanotubes, using the Euler-Bernoulli classical beam theory to model the nanotube as a continuum structure. Our aim has been to compute the effect of the fluid flow on the structural stability of the nanotubes, without having to consider the details of the fluid-walls interaction. The variations of the resonant frequencies with the flow velocity are obtained for both unembedded nanotubes, and when they are embedded in an elastic medium. It is found that a nanotube conveying a viscous fluid is more stable against vibration-induced buckling than a nanotube conveying a non-viscous fluid, and that the aspect ratio plays the same role in both cases.

  10. Computational modelling of the flow of viscous fluids in carbon nanotubes

    International Nuclear Information System (INIS)

    Khosravian, N; Rafii-Tabar, H

    2007-01-01

    Carbon nanotubes will have extensive application in all areas of nano-technology, and in particular in the field of nano-fluidics, wherein they can be used for molecular separation, nano-scale filtering and as nano-pipes for conveying fluids. In the field of nano-medicine, nanotubes can be functionalized with various types of receptors to act as bio-sensors for the detection and elimination of cancer cells, or be used as bypasses and even neural connections. Modelling fluid flow inside nanotubes is a very challenging problem, since there is a complex interplay between the motion of the fluid and the stability of the walls. A critical issue in the design of nano-fluidic devices is the induced vibration of the walls, due to the fluid flow, which can promote structural instability. It has been established that the resonant frequencies depend on the flow velocity. We have studied, for the first time, the flow of viscous fluids through multi-walled carbon nanotubes, using the Euler-Bernoulli classical beam theory to model the nanotube as a continuum structure. Our aim has been to compute the effect of the fluid flow on the structural stability of the nanotubes, without having to consider the details of the fluid-walls interaction. The variations of the resonant frequencies with the flow velocity are obtained for both unembedded nanotubes, and when they are embedded in an elastic medium. It is found that a nanotube conveying a viscous fluid is more stable against vibration-induced buckling than a nanotube conveying a non-viscous fluid, and that the aspect ratio plays the same role in both cases

  11. Total volume and composition of fluid intake and mortality in older women: a cohort study

    Science.gov (United States)

    Lim, Wai H; Wong, Germaine; Lewis, Joshua R; Lok, Charmaine E; Polkinghorne, Kevan R; Hodgson, Jonathan; Lim, Ee M; Prince, Richard L

    2017-01-01

    Objectives The health benefits of ‘drinking at least 8 glasses of water a day” in healthy individuals are largely unproven. We aimed to examine the relationship between total fluid and the sources of fluid consumption, risk of rapid renal decline, cardiovascular disease (CVD) mortality and all-cause mortality in elderly women. Design, setting and participants We conducted a longitudinal analysis of a population-based cohort study of 1055 women aged ≥70 years residing in Australia. Main outcome measures The associations between total daily fluid intake (defined as total volume of beverage excluding alcohol and milk) and the types of fluid (water, black tea, coffee, milk and other fluids) measured as cups per day and rapid renal decline, CVD and all-cause mortality were assessed using adjusted logistic and Cox regression analyses. Results Over a follow-up period of 10 years, 70 (6.6%) experienced rapid renal decline and 362 (34.4%) died, of which 142 (13.5%) deaths were attributed to CVD. The median (IQR) intake of total fluid was 10.4 (8.5–12.5) cups per day, with water (median (IQR) 4 (2–6) cups per day) and black tea (median (IQR) 3 (1–4) cups per day) being the most frequent type of fluid consumed. Every cup per day higher intake of black tea was associated with adjusted HRs of 0.90 (95% CI 0.81 to 0.99) and 0.92 (95% CI 0.86 to 0.98) for CVD mortality and all-cause mortality, respectively. There were no associations between black tea intake and rapid renal decline, or between the quantity or type of other fluids, including water intake, and any clinical outcomes. Conclusions Habitual higher intake of black tea may potentially improve long-term health outcomes, independent of treating traditional CVD risk factors, but validation of our study findings is essential. PMID:28341683

  12. Existence of the passage to the limit of an inviscid fluid.

    Science.gov (United States)

    Goldobin, Denis S

    2017-11-24

    In the dynamics of a viscous fluid, the case of vanishing kinematic viscosity is actually equivalent to the Reynolds number tending to infinity. Hence, in the limit of vanishing viscosity the fluid flow is essentially turbulent. On the other hand, the Euler equation, which is conventionally adopted for the description of the flow of an inviscid fluid, does not possess proper turbulent behaviour. This raises the question of the existence of the passage to the limit of an inviscid fluid for real low-viscosity fluids. To address this question, one should employ the theory of turbulent boundary layer near an inflexible boundary (e.g., rigid wall). On the basis of this theory, one can see how the solutions to the Euler equation become relevant for the description of the flow of low-viscosity fluids, and obtain the small parameter quantifying accuracy of this description for real fluids.

  13. Fundamental study on turbulent fluid mixing characteristics in piping systems. Fundamental study on fluid mixing mechanism in T-junction areas

    International Nuclear Information System (INIS)

    Toda, Saburo; Yuki, Kazuhisa; Muramatsu, Toshiharu

    2002-03-01

    In a region where two fluids with different temperatures are mixed together, unsteady temperature fluctuation, i.e. thermal striping, occurs in going through the unstable mixing process of the fluids, and structural materials in the surrounding area may be damaged by high-cycle thermal fatigue. In this report, in order to clarify the relation between the thermal striping and temperature fluctuation of structural wall, PIV measuring system is applied to visualize the fluid mixing state in a T-junction area in which important parameters for the fluid mixing are the flow velocity and aperture ratios of a main pipe to a small pipe and an incidence angle of the small pipe to the main pipe as well as temperature difference of the two flows. As a result of visualization experiments in a isothermal field, it is confirmed that a jet-axis, which is a stream line flowing out from the center of the small pipe, vibrates unsteadily and that its behavior is strongly affected by circulating flow, Karman vortex formed behind the jet axis, and especially flow-fluctuation which exists as a background-flow in the main pipe. Especially, the frequency band of the flow-fluctuation in the main pipe almost corresponds to that of the vibration of the jet-axis where the ratio of flow rate is low. Furthermore, in order to estimate the vibration state of the jet-axis and to find out the conditions for preventing the thermal fatigue, the penetration depth of the jet-axis is generalized. From measurements of temperature fluctuation of wall, it is shown that a high power fluctuation area exists universally behind the junction point of the small pipe where the flow rate of the small pipe flow is relatively lower than that of the main pipe flow. The band of dominant frequency of the temperature fluctuation is almost the same as the flow-fluctuation and the jet-axis vibration mentioned above. In addition, visualization experiments of secondary flow formed in a 90-degree bend, which is installed

  14. Neuro-ophthalmological manifestations of neurosyphilis in 22 cases

    Directory of Open Access Journals (Sweden)

    Xiao-Juan Fan

    2017-10-01

    Full Text Available AIM: To analyze the characteristics of neurological ophthalmology manifestation of patients with neurosyphilis.METHODS: Retrospective and nonrandomized case analysis were used. Totally 22 cases of 39 eyes were included. They were 17 males and 5 females, aged from 34 to 65 years old. The average age were 49.6 years old. RESULTS: The optic nerve atrophy presented in 11 cases of 22 eyes. One eye of them accompanied by left eye oculomotor nerve palsy; 5 eyes in 3 cases expressed as optic neuritis acute phase; neuroretinitis appeared in 4 cases of 6 eyes; 1 case of 2 eyes expressed as chorioretinitis accompanied by optic disc edema; central retinal artery occlusion were found in 1 case of 1 eye. Argyll-Robertson pupil was as only manifestation in 2 cases of 3 eyes. In all cases, Argyll-Robertson pupil signs can be seen in 19 eyes. Treponema pallidum particle agglutination test(TPPAwere positive in all 22 cases. Syphilis rapid plasma reactin test(RPRwere positive in 19 of 21 cases. All patients underwent lumbar puncture and cerebrospinal fluid were detected for RPR, cerebrospinal fluid protein, white blood cell count. Cerebrospinal fluid RPR were positive in 13 cases. Cerebrospinal fluid protein were greater than 450mg/L in 18 cases. Cerebrospinal fluid white blood cell count were greater than 5/mm3 in 13 cases. CONCLUSION: Neurosyphilis involving neuro-ophthalmology often occurs in middle-aged men and subacute onset. Both eyes can suffered from optic nerve disease simultaneously or sequencely. A few can be expressed as other cranial nerve palsy, which may lead to misdiagnosis. Considering medical history, clinical manifestations, ophthalmic examination, serum and cerebrospinal fluid laboratory tests can improve the diagnostic rate.

  15. Effect of pre-donation fluid intake on fluid shift from interstitial to intravascular compartment in blood donors.

    Science.gov (United States)

    Deepika, Chenna; Murugesan, Mohandoss; Shastry, Shamee

    2018-02-01

    Fluid shifts from interstitial to intravascular space during blood donation helps in compensating the lost blood volume. We aimed to determine the volume of fluid shift following donation in donors with and without pre-donation fluid intake. We studied the fluid shift in 325 blood donors prospectively. Donors were divided in groups- with no fluid intake (GI) and either water (GII) or oral rehydrating fluids (GIII) before donation. Fluid shift following donation was calculated based on the difference between the pre and post donation blood volume. The influence of oral fluid intake, age, gender and body mass index (BMI) on volume of fluid shift was analyzed. The fluid shift was significant between donors without fluids (GI: 127 ± 81 ml) and donors with fluid intake (GII & III: 96 ± 45 ml) (p donation. As per our observation, the oral fluids before donation might not contribute to increase in fluid shift in blood donors after donation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Fluid-structure interaction with pipe-wall viscoelasticity during water hammer

    Science.gov (United States)

    Keramat, A.; Tijsseling, A. S.; Hou, Q.; Ahmadi, A.

    2012-01-01

    Fluid-structure interaction (FSI) due to water hammer in a pipeline which has viscoelastic wall behaviour is studied. Appropriate governing equations are derived and numerically solved. In the numerical implementation of the hydraulic and structural equations, viscoelasticity is incorporated using the Kelvin-Voigt mechanical model. The equations are solved by two different approaches, namely the Method of Characteristics-Finite Element Method (MOC-FEM) and full MOC. In both approaches two important effects of FSI in fluid-filled pipes, namely Poisson and junction coupling, are taken into account. The study proposes a more comprehensive model for studying fluid transients in pipelines as compared to previous works, which take into account either FSI or viscoelasticity. To verify the proposed mathematical model and its numerical solutions, the following problems are investigated: axial vibration of a viscoelastic bar subjected to a step uniaxial loading, FSI in an elastic pipe, and hydraulic transients in a pressurised polyethylene pipe without FSI. The results of each case are checked with available exact and experimental results. Then, to study the simultaneous effects of FSI and viscoelasticity, which is the new element of the present research, one problem is solved by the two different numerical approaches. Both numerical methods give the same results, thus confirming the correctness of the solutions.

  17. Analysis of fluid induced vibration of cryogenic pipes in consideration of the cooling effect

    International Nuclear Information System (INIS)

    Kim, Bong Soo; Kim, Young Ki; Choi, Jung Woon

    2008-01-01

    The purpose of system analysis using fluid induced vibration is to identify the problems of the system in advance by analyzing the vibration behavior of the system excited by fluid flow. Fluid-induced vibration analysis methods, developed so far, generally use the numerical analysis method to analyze the fluid flowing inside the pipe and the infinitesimal elements at normal temperature on the basis of the governing equation obtained by applying Newton's Second Law and the momentum equation. However, as the fluid temperature changes greatly at low temperature, fluid-induced vibration analysis methods for normal temperature cannot be applied. This study investigated methods of analyzing fluid-induced vibration in consideration of the cooling effect. In consideration of the changes in the properties of the fluid and system relative to temperature, vibration behavior was analyzed numerically by means of the equation of motion. As a result, the natural frequency of the system tends to change because of the changes of the properties of materials even when the flux is constant inside the pipe, and the vibration behavior of the system was compared to that in case of normal temperature to analyze how much influence the cooling effect has on the vibration behavior of the system

  18. Intrapartum amnioinfusion for meconium-stained fluid: meta-analysis of prospective clinical trials.

    Science.gov (United States)

    Pierce, J; Gaudier, F L; Sanchez-Ramos, L

    2000-06-01

    To evaluate the effectiveness of intrapartum prophylactic amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid. We identified prospective clinical trials of amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid (AF) published in English by using computerized databases, references in published studies, and index reviews. We analyzed prospective studies of intrapartum amnioinfusion for meconium-stained AF. In every case, group allocation was based exclusively on meconium in AF. Only published studies with clearly documented outcome data were included. The trials were evaluated for meconium below the vocal cords, meconium aspiration syndrome, fetal acidemia, cesarean delivery, and postpartum endometritis. Each trial was evaluated for the quality of its methodology, inclusion and exclusion criteria, adequacy of randomization, amnioinfusion protocols, definition of outcomes, and statistical analyses. Thirteen studies met inclusion criteria for our systematic review. Odds ratios (ORs) with their 95% confidence intervals (CIs) were calculated for each outcome. Estimates of ORs and risk differences for dichotomous outcomes were calculated using random and fixed-effects models. We tested for homogeneity across the studies. We found that intrapartum amnioinfusion significantly reduced the frequency of meconium aspiration syndrome (OR 0.30; 95% CI 0.19, 0. 46), of meconium below the vocal cords, and neonatal acidemia. Subjects allocated to receive amnioinfusion also had a significantly lower overall cesarean rate (OR 0.74, 95% CI 0.59, 0.93) without increased postpartum endometritis. Amnioinfusion in cases of meconium-stained fluid significantly improves neonatal outcome, lowers the cesarean delivery rate, and does not increase the postpartum endometritis rate.

  19. Computational Fluid Dynamic Analysis of a Vibrating Turbine Blade

    Directory of Open Access Journals (Sweden)

    Osama N. Alshroof

    2012-01-01

    Full Text Available This study presents the numerical fluid-structure interaction (FSI modelling of a vibrating turbine blade using the commercial software ANSYS-12.1. The study has two major aims: (i discussion of the current state of the art of modelling FSI in gas turbine engines and (ii development of a “tuned” one-way FSI model of a vibrating turbine blade to investigate the correlation between the pressure at the turbine casing surface and the vibrating blade motion. Firstly, the feasibility of the complete FSI coupled two-way, three-dimensional modelling of a turbine blade undergoing vibration using current commercial software is discussed. Various modelling simplifications, which reduce the full coupling between the fluid and structural domains, are then presented. The one-way FSI model of the vibrating turbine blade is introduced, which has the computational efficiency of a moving boundary CFD model. This one-way FSI model includes the corrected motion of the vibrating turbine blade under given engine flow conditions. This one-way FSI model is used to interrogate the pressure around a vibrating gas turbine blade. The results obtained show that the pressure distribution at the casing surface does not differ significantly, in its general form, from the pressure at the vibrating rotor blade tip.

  20. Contribution to the modeling of particulate hypersonic flows. Study and validation of a discrete two-fluid model

    International Nuclear Information System (INIS)

    Papin, M.

    2005-06-01

    This work dedicated to the study of the hypersonic re-entry of vehicles in the atmosphere crossing clouds of particles implies the study of two-fluid flow and it is shown that some developments can be applied to the two-fluid models used to describe the phase transformation occurring in a target irradiated by laser beams. The calculation of wall fluxes on hypersonic re-entry vehicles requires the modeling of the interactions with clouds. Two-fluid flows posing many physical and mathematical problems, one studies an alternative model due to Abgrall and Saurel: the discrete equation method (DEM). Three axis are chosen. The first proposes a finite volume discretization of the Navier-Stokes equations on hybrid grids adapted to the context. The second extends the DEM within a multi-fluid not-structured N-D framework. A limit study associates an original continuous model to him: it allows to modify usual two-fluid seven equations models to obtain a phasic entropy principle. In spite of good properties, the continuous description of the particles is unsuited to the problem. The last axis is a study of the follow-up of pointwise particles which does not allow realistic calculation of parietal fluxes. An original model, extending the usual hydro-erosion models, however makes it possible to evaluate rebounds, erosion of the body and wall fluxes. The appendices expose approximate and exact Riemann solvers between pure fluids, discretization of the Baer and Nunziato model, and relations describing the atmosphere, water and heat fluxes