  1. Screen-printed sensor for batch and flow injection potentiometric chromium(VI) monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Moreno, Raul A.; Gismera, M.J.; Sevilla, M.T.; Procopio, Jesus R. [Facultad de Ciencias, Universidad Autonoma de Madrid, Departamento de Quimica Analitica y Analisis Instrumental, Madrid (Spain)

    2010-05-15

    A disposable screen-printed electrode was designed and evaluated for direct detection of chromium(VI) in batch and flow analysis. The carbon screen-printed electrode was modified with a graphite-epoxy composite. The optimal graphite-epoxy matrix contains 37.5% graphite powder, 12.5% diphenylcarbohydrazide, a selective compound for chromium(VI), and 50% epoxy resin. The principal analytical parameters of the potentiometric response in batch and flow analysis were optimized and calculated. The screen-printed sensor exhibits a response time of 20 {+-} 1 s. In flow analysis, the analytical frequency of sampling is 70 injections per hour using 0.1 M NaNO{sub 3} solution at pH 3 as the carrier, a flow rate of 2.5 mL.min{sup -1}, and an injection sample volume of 0.50 mL. The sensor shows potentiometric responses that are very selective for chromium(VI) ions and optimal detection limits in both static mode (2.1 x 10{sup -7} M) and online analysis (9.4 x 10{sup -7} M). The disposable potentiometric sensor was employed to determine toxicity levels of chromium(VI) in mineral, tap, and river waters by flow-injection potentiometry and batch potentiometry. Chromium(VI) determination was also carried out with successful results in leachates from municipal solid waste landfills. (orig.)

  2. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  3. Carbon paste electrode modified with silver thimerosal for the potentiometric flow injection analysis of silver(I)

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Hosny [Chemistry Department, Faculty of Science, Cairo University, Cairo (Egypt)]. E-mail: dr_hosny@yahoo.com

    2005-07-27

    The utility of carbon paste electrode modified with silver ethylmercurythiosalicylate (silver thimerosal) in both static mode and flow injection analysis (FIA) is demonstrated. The electrode was fully characterized in terms of composition, response time, thermal stability, usable pH and ionic strength ranges. It has been shown that diisononyl phthalate (DINP) acts as more suitable solvent mediator for preparation of the electrode, which exhibits linear response range to Ag(I) extending from 5.0 x 10{sup -7} to 1.0 x 10{sup -3} M with detection limit of 2.5 x 10{sup -7} M and Nernstian slope of 59.3 {+-} 1.0 mV/decade. The proposed chemically modified carbon paste electrode shows a very good selectivity for Ag(I) over a wide variety of metal ions and successfully used for the determination of the silver content of silver sulphadiazine (burning cream) and developed radiological films. The electrode was also used as an indicator electrode in the potentiometric titration of thiopental and thimerosal with AgNO{sub 3}.

  4. Determinação potenciométrica em fluxo de cloreto de cetilpiridinio em desinfectantes bucais Potentiometric determination of cetylpyridinium chloride in oral desinfectants by flow injection analysis

    Directory of Open Access Journals (Sweden)

    Paula C. S. Baptista

    2003-08-01

    Full Text Available The work describes a new procedure for cetylpyridinium chloride determination in oral disinfectants, based on a flow-injection system with potentiometric detection. The determination was based on the measurement of picrate concentration decrease as result of ion-pair reaction with the analyte present in the injected sample. In the optimised set-up the sample injection volume was kept at 400 µL and merged downstream with the reagent solution containing 1,0 x10-5 mol/L of picrate adjusted to pH 5.0 with citrate/citric acid buffer. The flow rate was fixed at 8 mL/min and the reactor length at 40 cm. The proposed procedure enables the determination of cetylpyridinium in the analytical range of 5,0x10-6 - 7,5x10-5 mol/L at a sampling rate of 60/h. The results for real samples had a precision better than 3% and were comparable to the labelled values.

  5. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    Science.gov (United States)

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  6. Construction and performance characterization of ion-selective electrodes for potentiometric determination of pseudoephedrine hydrochloride applying batch and flow injection analysis techniques.

    Science.gov (United States)

    Zayed, Sayed I M; Issa, Yousry M; Hussein, Ahmed

    2006-01-01

    New pseudoephedrine selective electrodes have been constructed of the conventional polymer membrane type by incorporation of pseudoephedrine-phosphotungstate (PE-PT) or pseudoephedrine-silicotungstate (PE-SiT) ion-associates in a poly vinyl chloride (PVC) membrane plasticized with dibutyl phthalate (DBP). The electrodes were fully characterized in terms of the membrane composition, temperature, and pH. The electrodes exhibited mean slopes of calibration graphs of 57.09 and 56.10 mV concentration decade(-1) of PECl at 25 degrees C for (PE-PT) and (PE-SiT) electrodes, respectively. The electrodes showed fast, stable, and near-Nernstian response over the concentration ranges 6.31 x 10(-6)-1.00 x 10(-2) and 5.00 x 10(-5)-1.00x10(-2) M in the case of PE-PT applying batch and flow injection (FI) analysis, respectively, and 1.00 x 10(-5)-1.00 x 10(-2) and 5.00 x 10(-5)-1.00x10(-2) M in the case of PE-SiT for batch and FI analysis system, respectively. Detection limit was 5.01x 10(-6) M for PE-PT electrode and 6.31x10(-6) M for PE-SiT electrode. The electrodes were successfully applied for the potentiometric determination of pseudoephedrine hydrochloride (PECl) in pharmaceutical preparations with mean recovery 101.13 +/- 0.85% and 100.77+0.79% in case of PE-PT applying batch and flow injection systems, respectively, and 100.75+0.85% and 100.79 +/- 0.77% in case of PE-SiT for batch and flow injection systems, respectively. The electrodes exhibited good selectivity for PECl with respect to a large number of inorganic cations, sugars and amino acids.

  7. Potentiometric flow injection system for determination of reductants using a polymeric membrane permanganate ion-selective electrode based on current-controlled reagent delivery.

    Science.gov (United States)

    Song, Wenjing; Ding, Jiawang; Liang, Rongning; Qin, Wei

    2011-10-17

    A polymeric membrane permanganate-selective electrode has been developed as a current-controlled reagent release system for potentiometric detection of reductants in flow injection analysis. By applying an external current, diffusion of permanganate ions across the polymeric membrane can be controlled precisely. The permanganate ions released at the sample-membrane interface from the inner filling solution of the electrode are consumed by reaction with a reductant in the sample solution thus changing the measured membrane potential, by which the reductant can be sensed potentiometrically. Ascorbate, dopamine and norepinephrine have been employed as the model reductants. Under the optimized conditions, the potential peak heights are proportional to the reductant concentrations in the ranges of 1.0×10(-5) to 2.5×10(-7)M for ascorbate, of 1.0×10(-5) to 5.0×10(-7)M for dopamine, and of 1.0×10(-5) to 5.0×10(-7)M for norepinephrine, respectively with the corresponding detection limits of 7.8×10(-8), 1.0×10(-7) and 1.0×10(-7)M. The proposed system has been successfully applied to the determination of reductants in pharmaceutical preparations and vegetables, and the results agree well with those of iodimetric analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine

    Directory of Open Access Journals (Sweden)

    Suad Mustafa Al-Araji

    2011-01-01

    Full Text Available Plasticised poly(vinyl chloride-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD, dibenzo-18-crown-6 (DB18C6 and dibenzo-30-crown-10 (DB30C10 were evaluated for their potentiometric response towards promethazine (PM in a flow injection analysis (FIA set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl borate (KTPB was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl adipate (BEHA and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose. FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream were also studied when the best sensor was used (based on β-CD. The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.

  9. Determination of the total acidity in soft drinks using potentiometric sequential injection titration.

    Science.gov (United States)

    van Staden, J Koos F; Mashamba, M Mulalo G; Stefan, R Raluca I

    2002-12-06

    A potentiometric SI titration system for the determination of total acidity in soft drinks is proposed. The concept is based on the aspiration of the acid soft drink sample between two base zones into a holding coil with the volume of the first base zone twice to that of the second one and channelled by flow reversal through a reaction coil to a potentiometric sensor. A solution of 0.1 mol l(-1) sodium chloride is used as ionic strength adjustment buffer in the carrier stream. The system has been applied to the analysis of some South African soft drinks having a total acidity level of about 0.2-0.3% (w/v). The method has a sample frequency of 45 samples per h with a linear range of 0.1 and 0.6% (w/v). It is easy to use, fully computerised, and gives the results that are comparable to both automated batch titration and manual titration.

  10. Improved Performance of the Potentiometric Biosensor for the Determination of Creatinine

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Zachau-Christiansen, Birgit

    2007-01-01

    The development of potentiometric biosensors for the determination of creatinine is attractive because it is a frequently analysed species in clinical chemistry. Contemporary methods of analysing creatinine engage chemicals harmful to the environment and generate large volumes of waste disposals....... By introducing a membrane-based potentiometric biosensor with immobilised creatinine deaminase, the measurements can be performed by miniaturised portable devices that are easy to handle and allow rapid analysis at a minimum consumption of chemicals. Thus, the enzymatic creatinine biosensors was revisited...... performed by flow injection analysis (FIA) showed that the response time could be lowered to approx. 30 sec. using sample volumes of 30 L. Interferences were corrected for by application of the Nicolsky-Eisenman equation thus allowing determination of creatinine in matrices resembling those of clinical...

  11. Integrated potentiometric detector for use in chip-based flow cells

    Science.gov (United States)

    Tantra; Manz

    2000-07-01

    A new kind of potentiometric chip sensor for ion-selective electrodes (ISE) based on a solvent polymeric membrane is described. The chip sensor is designed to trap the organic cocktail inside the chip and to permit sample solution to flow past the membrane. The design allows the sensor to overcome technical problems of ruggedness and would therefore be ideal for industrial processes. The sensor performance for a Ba2+-ISE membrane based on a Vogtle ionophore showed electrochemical behavior similar to that observed in conventional electrodes and microelectrode arrangements.

  12. The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations.

    Science.gov (United States)

    Altiokka, G; Atkosar, Z; Can, N O

    2002-10-15

    A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.

  13. Potentiometric titration curves of aluminium salt solutions and its ...

    African Journals Online (AJOL)

    Potentiometric titration curves of aluminium salt solutions and its species conversion ... of aluminium salt solutions under the moderate slow rate of base injection. ... silicate radical, and organic acid radical on the titration curves and its critical ...

  14. Potentiometric chip-based multipumping flow system for the simultaneous determination of fluoride, chloride, pH, and redox potential in water samples.

    Science.gov (United States)

    Chango, Gabriela; Palacio, Edwin; Cerdà, Víctor

    2018-08-15

    A simple potentiometric chip-based multipumping flow system (MPFS) has been developed for the simultaneous determination of fluoride, chloride, pH, and redox potential in water samples. The proposed system was developed by using a poly(methyl methacrylate) chip microfluidic-conductor using the advantages of flow techniques with potentiometric detection. For this purpose, an automatic system has been designed and built by optimizing the variables involved in the process, such as: pH, ionic strength, stirring and sample volume. This system was applied successfully to water samples getting a versatile system with an analysis frequency of 12 samples per hour. Good correlation between chloride and fluoride concentration measured with ISE and ionic chromatography technique suggests satisfactory reliability of the system. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, September 2008

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2009-01-01

    This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for September 2008. Potentiometric contours are based on water-level measurements collected at 589 wells during the period September 15-25, near the end of the wet season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  16. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, May 2009

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2009-01-01

    This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for May 2009. Potentiometric contours are based on water-level measurements collected at 625 wells during the period May 14 - May 29, near the end of the dry season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to groundwater withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Groundwater withdrawals locally have lowered the potentiometric surface. Groundwater in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  17. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, September 2007

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2008-01-01

    This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for September 2007. Potentiometric contours are based on water-level measurements collected at 554 wells during the period September 15-27, near the end of the wet season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  18. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, September 2006

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2007-01-01

    Introduction This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for September 2006. Potentiometric contours are based on water-level measurements collected at 571 wells during the period September 11-29, near the end of the wet season. Some contours are inferred from previouspotentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  19. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, May 2007

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2007-01-01

    Introduction This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for May 2007. Potentiometric contours are based on water-level measurements collected at 566 wells during the period May 4-June 11 near the end of the dry season, however most of the water level data for this map were collected by the U.S. Geological Survey during the period May 21-25, 2007. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  20. Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis.

    Science.gov (United States)

    Vahl, Katja; Kahlert, Heike; von Mühlen, Lisandro; Albrecht, Anja; Meyer, Gabriele; Behnert, Jürgen

    2013-07-15

    A FIA system using a pH-sensitive detector based on a graphite/quinhydrone/silicone composite electrode was applied to determine sequentially the titratable acidity and the pH of wine, as well as the sum of calcium and magnesium ions. For all measurements the same FIA configuration was used employing different carrier solutions. The results for the determination of acidity and pH are in good agreement with those obtained by classical potentiometric titrations and by pH measurements using a conventional glass electrode. The standard deviation was less than 1.5% for both kinds of measurements and the sample volume was 150 μL. The method allows about 40 determinations of titratable acidity per hour and 30 pH measurements per hour. The titration method can be adjusted to the legal requirements in USA and Europe. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. The impact of interpreted flow regimes during constant head injection tests on the estimated transmissivity from injection tests and difference flow logging

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Ludvigsson, Jan-Erik; Harrstroem, Johan [Geosigma AB, Uppsala (Sweden)

    2013-04-15

    A large number of constant head injection tests were carried out in the site investigation at Forsmark using the Pipe String System, PSS3. During the original evaluation of the tests the dominating transient flow regimes during both the injection and recovery period were interpreted together with estimation of hydraulic parameters. The flow regimes represent different flow and boundary conditions during the tests. Different boreholes or borehole intervals may display different distributions of flow regimes. In some boreholes good agreement was obtained between the results of the injection tests and difference flow logging with Posiva flow log (PFL) but in other boreholes significant discrepancies were found. The main objective of this project is to study the correlation between transient flow regimes from the injection tests and other borehole features such as transmissivity, depth, geology, fracturing etc. Another subject studied is whether observed discrepancies between estimated transmissivity from difference flow logging and injection tests can be correlated to interpreted flow regimes. Finally, a detailed comparison between transient and stationary evaluation of transmissivity from the injection tests in relation to estimated transmissivity from PFL tests in corresponding sections is made. Results from previous injection tests in 5 m sections in boreholes KFM04, KFM08A and KFM10A were used. Only injection tests above the (test-specific) measurement limit regarding flow rate are included in the analyses. For all of these tests transient flow regimes were interpreted. In addition, results from difference flow logging in the corresponding 5 m test sections were used. Finally, geological data of fractures together with rock and fracture zone properties have been used in the correlations. Flow regimes interpreted from the injection period of the tests are generally used in the correlations but deviations between the interpreted flow regimes from the injection and

  2. Potentiometric perchlorate determination at nanomolar concentrations in vegetables.

    Science.gov (United States)

    Leoterio, Dilmo M S; Paim, Ana Paula S; Belian, Mônica F; Galembeck, André; Lavorante, André F; Pinto, Edgar; Amorim, Célia G; Araújo, Alberto N; Montenegro, Maria C B S M

    2017-07-15

    In this work, an expeditious method based on the multi-commutated flow-analysis concept with potentiometric detection is proposed to perform determinations of the emergent contaminant perchlorate in vegetable matrices down to nanomolar concentration. To accomplish the task, a tubular shaped potentiometric sensor selective to perchlorate ion was constructed with a PVC membrane containing 12mmol/kg of the polyamine bisnaphthalimidopropyl-4,4'-diaminodiphenylmethane and 2-nitrophenyl phenyl ether 68% (w/w) as plasticizer casted on a conductive epoxy resin. Under optimal flow conditions, the sensor responded linearly in the concentration range of 6.3×10 -7 -1.0×10 -3 mol/L perchlorate. In order to extend the determinations to lower concentrations (4.6(±1.3)×10 -10 mol/L perchlorate), a column packed with 70mg of sodium 2,5,8,11,14-pentaoxa-1-silacyclotetradecane-polymer was coupled to the flow-system thus enabling prior pre-concentration of the perchlorate. The proposed procedure provides a simpler alternative for the determination of perchlorate in foods, nowadays only allowed by sophisticated and expensive equipment and laborious methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Potentiometric surface of the Upper Floridan aquifer in the St. Johns River water management district and vicinity, Florida, September 2005

    Science.gov (United States)

    Kinnaman, Sandra L.

    2006-01-01

    This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for September 2005. Potentiometric contours are based on water-level measurements collected at 643 wells during the period September 12-28, near the end of the wet season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and springflow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  4. Potentiometric surface of the upper Floridan Aquifer in the St. Johns River Water Management District and vicinity, Florida, September, 2004

    Science.gov (United States)

    Kinnaman, Sandra L.

    2005-01-01

    Introduction: This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity in September 2004. Potentiometric contours are based on water-level measurements collected at 608 wells during the period September 14-October 1, near the end of the wet season. The shapes of some contours have been inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  5. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, May 2005

    Science.gov (United States)

    Kinnaman, Sandra L.

    2006-01-01

    INTRODUCTION This map depicts the potentiometric surface of the upper Floridan aquifer in the St. Johns River Water Management District and vicinity for May 2005. Potentiometric contours are based on water level measurements collected at 598 wens during the period May 5 - 31, near the end of the dry season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate upper Floridan aquifer responds mainly to rainfall, and more locally, to ground water withdrawals. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground water withdrawals locally have lowered the potentiometric surface. Ground water in the upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  6. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, May, 2004

    Science.gov (United States)

    Kinnaman, Sandra L.; Knowles, Leel

    2004-01-01

    INTRODUCTION This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity in May 2001. Potentiometric contours are based on water-level measurements collected at 684 wells during the period May 2 - 30, near the end of the dry season. The shapes of some contours have been inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  7. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, Florida, May 2006

    Science.gov (United States)

    Kinnaman, Sandra L.

    2006-01-01

    Introduction: This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for May 2006. Potentiometric contours are based on water-level measurements collected at 599 wells during the period May 14-31, near the end of the dry season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and springflow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours.

  8. Potentiometric Surface of the Upper Floridan Aquifer in the St. Johns River Water Management District and Vicinity, May 2008

    Science.gov (United States)

    Kinnaman, Sandra L.; Dixon, Joann F.

    2008-01-01

    This map depicts the potentiometric surface of the Upper Floridan aquifer in the St. Johns River Water Management District and vicinity for May 2008. Potentiometric contours are based on water-level measurements collected at 567 wells during the period May 6-May 27, near the end of the dry season. Some contours are inferred from previous potentiometric-surface maps with larger well networks. The potentiometric surface of the carbonate Upper Floridan aquifer responds mainly to rainfall, and more locally, to ground-water withdrawals and spring flow. Potentiometric-surface highs generally correspond to topographic highs where the aquifer is recharged. Springs and areas of diffuse upward leakage naturally discharge water from the aquifer and are most prevalent along the St. Johns River. Areas of discharge are reflected by depressions in the potentiometric surface. Ground-water withdrawals locally have lowered the potentiometric surface. Ground water in the Upper Floridan aquifer generally flows from potentiometric highs to potentiometric lows in a direction perpendicular to the contours. Measured values of the potentiometric surface ranged from 7 feet below NGVD29 near Fernandina Beach, Florida, to 124 feet above NGVD29 in Polk County, Florida. The average water level of the network in May 2008 was about 1 foot lower than the average in September 2007 following below-average rainfall during the dry season of 2007-08. Seasonal differences in network average water levels generally range from 4 to 6 feet. For 457 wells with previous measurements, May 2008 levels ranged from about 19 feet below to about 11 feet above September 2007 water levels. The average water level of the network in May 2008 was about 1 foot higher than the average in May 2007. For 544 wells with previous measurements, May 2008 levels ranged from about 8 feet below to about 13 feet above May 2007 water levels. Long-term hydrographs of ground-water levels for continuous and periodic wells are available

  9. A volumetric flow sensor for automotive injection systems

    International Nuclear Information System (INIS)

    Schmid, U; Krötz, G; Schmitt-Landsiedel, D

    2008-01-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature

  10. A volumetric flow sensor for automotive injection systems

    Science.gov (United States)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  11. Flow Injection Analysis in Industrial Biotechnology

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2009-01-01

    Flow injection analysis (FIA) is an analytical chemical continuous-flow (CF) method which in contrast to traditional CF-procedures does not rely on complete physical mixing (homogenisation) of the sample and the reagent(s) or on attaining chemical equilibria of the chemical reactions involved. Ex...

  12. Permian potentiometric analysis

    International Nuclear Information System (INIS)

    Devary, J.L.

    1983-09-01

    Pacific Northwest Laboratory (PNL) was requested to analyze potentiometric data from the Wolfcamp Formation of the Permian System to evaluate the recommendations by the University of Texas/Bureau of Economic Geology (UT/BEG) that additional geohydrologic boreholes be drilled into the Wolfcamp. The UT/BEG recommended that two stratigraphic and two geohydrologic borings be drilled into the Permian System during FY83 and that several shallow hydrologic tests be made in the Dockum Formation. A geostatistical technique known as kriging was applied to objectively evaluate these geohydrologic borehole recommendations. The Deaf Smith County location appears to be an excellent choice for a borehole. No high quality potentiometric data are available from Deaf Smith County and a borehole location immediately upgradient from the candidate repository site is needed. Adding this borehole location to the potentiometric data base will significantly reduce field data uncertainty near the location being studied. The Swisher County location does not appear to be the best choice. High quality data values H2206 and H2360 are located immediately upgradient from the proposed repository site. The best placement of additional geohydrological boreholes in the Wolfcamp Formation depends strongly upon the proposed repository location. The variability of the potentiometric data causes estimation errors to rapidly increase away from locations of field measurements. Suggested locations for additional boreholes for the Deaf Smith investigations are in northwest Randall or central Potter Counties. Ideal borehole locations for the Swisher county studies appear to be in southeast Randall and Armstrong Counties

  13. An estimated potentiometric surface of the Death Valley region, Nevada and California, developed using geographic information system and automated interpolation techniques

    International Nuclear Information System (INIS)

    D'Agnese, F.A.; Faunt, C.C.; Turner, A.K.

    1998-01-01

    An estimated potentiometric surface was constructed for the Death Valley region, Nevada and California, from numerous, disparate data sets. The potentiometric surface was required for conceptualization of the ground-water flow system and for construction of a numerical model to aid in the regional characterization for the Yucca Mountain repository. Because accurate, manual extrapolation of potentiometric levels over large distances is difficult, a geographic-information-system method was developed to incorporate available data and apply hydrogeologic rules during contour construction. Altitudes of lakes, springs, and wetlands, interpreted as areas where the potentiometric surface intercepts the land surface, were combined with water levels from well data. Because interpreted ground-water recharge and discharge areas commonly coincide with groundwater basin boundaries, these areas also were used to constrain a gridding algorithm and to appropriately place local maxima and minima in the potentiometric-surface map. The resulting initial potentiometric surface was examined to define areas where the algorithm incorrectly extrapolated the potentiometric surface above the land surface. A map of low-permeability rocks overlaid on the potentiometric surface also indicated areas that required editing based on hydrogeologic reasoning. An interactive editor was used to adjust generated contours to better represent the natural water table conditions, such as large hydraulic gradients and troughs, or ''vees''. The resulting estimated potentiometric-surface map agreed well with previously constructed maps. Potentiometric-surface characteristics including potentiometric-surface mounds and depressions, surface troughs, and large hydraulic gradients were described

  14. Sequential injection lab-on-valve: the third generation of flow injection analysis

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    Termed the third generation of flow injection analysis, sequential injection (SI)-lab-on-valve (LOV) has specific advantages and allows novel, unique applications - not least as a versatile front end to a variety of detection techniques. This review presents snd discusses progress to date of the ...

  15. Groundwater Flow Systems at the Nevada Test Site, Nevada: A Synthesis of Potentiometric Contours, Hydrostratigraphy, and Geologic Structures

    Energy Technology Data Exchange (ETDEWEB)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.

    2010-01-25

    Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic

  16. Groundwater Flow Systems at the Nevada Test Site, Nevada: A Synthesis of Potentiometric Contours, Hydrostratigraphy, and Geologic Structures

    Science.gov (United States)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.

    2010-01-01

    Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic

  17. Automated injection of slurry samples in flow-injection analysis

    NARCIS (Netherlands)

    Hulsman, M.H.F.M.; Hulsman, M.; Bos, M.; van der Linden, W.E.

    1996-01-01

    Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed

  18. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  19. Flow improvers for water injection based on surfactants

    Energy Technology Data Exchange (ETDEWEB)

    Oskarsson, H.; Uneback, I.; Hellsten, M.

    2006-03-15

    In many cases it is desirable to increase the flow of injection water when an oil well deteriorates. It is very costly in offshore operation to lay down an additional water pipe to the injection site. Flow improvers for the injection water will thus be the most cost-effective way to increase the flow rate. During the last years water-soluble polymers have also been applied for this purpose. These drag-reducing polymers are however only slowly biodegraded which has been an incentive for the development of readily biodegradable surfactants as flow improvers for injection water. A combination of a zwitterionic and an anionic surfactant has been tested in a 5.5 inch, 700 m long flow loop containing sulphate brine with salinity similar to sea water. A drag reduction between 75 and 80% was achieved with 119 ppm in solution of the surfactant blend at an average velocity of 1.9 m/s and between 50 and 55% at 2.9 m/s. The surfactants in this formulation were also found to be readily biodegradable in sea water and low bio accumulating which means they have an improved environmental profile compared to the polymers used today. Due to the self-healing properties of the drag-reducing structures formed by surfactants, these may be added before the pump section - contrary to polymers which are permanently destroyed by high shear forces. (Author)

  20. Potentiometric titration with polarized electrodes

    International Nuclear Information System (INIS)

    Chikryzova, E.G.

    1977-01-01

    Based on the analysis of the works carried out during 1911-75 consideration is given to the present state of the method of potentiometric titration with polarized electrodes. The material is generalized in the tabular form indicating the elments of interest, titration conditions and the objects to be analyzed. The list and classification of the potentiometric titration methods intended for determining organic and inorganic substances are presented

  1. Potentiometric determination of molybdenum

    International Nuclear Information System (INIS)

    Rusina, O.N.; Gorbatkova, B.Kh.

    1977-01-01

    Potentiometric titration by lead acetate is used to determine molybdenum in the form of molybdate ions. The behaviour of bimetallic electrode couples, i.e. tungsten-lead, platinum-lead, lead-carbon electrode, molybdenum-carbon electrode platinum-molibdenum has been investigated. The greatest jump of the potential in the finite point is observed for platinum-molybdenum electrode couple (150 mV/ml at pH 4.0-5.5). The limiting concentration of molybdenum in potentiometric titration by lead acetate is 2.8x10 -4 M. The measurements are accurate to within +-0.1%

  2. Potentiometric titration of plutonium

    International Nuclear Information System (INIS)

    Silver, G.L.

    1978-01-01

    In the potentiometric titration of plutonium(III), it has been customary to take the equivalence point as the inflection point on a plot of potential vs. volume of titrant. It have not been, however, demonstrated, that the stoichiometric end point corresponds to the inflection point. Suggestions are made according to which these points may not correspond in the potentiometric titration of plutonium(III), as these titrations are ordinarily concluded in a period of time which is short compared to the time required for valence state rearrangement through disproportionation. (T.G.)

  3. Flow Injection Potentiometric Determination of Cd2+ Ions Using a Coated Graphite Plasticized PVC-Membrane Electrode Based on 1, 3-Bis(2-cyanobenzene)triazene.

    Science.gov (United States)

    Shamsipur, Mojtaba; Sahari, Shokat; Payehghadr, Mahmood; Alizadeh, Kamal

    2011-09-01

    1, 3-Bis(2-cyanobenzene)triazene, L, was used as a suitable ionophore for the fabrication of a new PVC-based polymeric membrane coated graphite electrode for selective sensing of Cd2+ ion. The electrode exhibited a selective linear Nernstian response to Cd2+ ion at an optimal pH range of 6-9 with a limit of detection of 8.0 × 10-6 M and a fast response time of about 2 s. The electrode was used as a proper detection system in flow-injection potentiometry of cadmium ion and resulted in well defined peaks for cadmium ions with stable baseline, excellent reproducibility and high sampling rates of over 100 injections per hour. It showed good stability, reproducibility and fast response time. The practical utility of the proposed system has also been reported.

  4. 3D-CFD Simulation of Confined Cross-Flow Injection Process Using Single Piston Pump

    Directory of Open Access Journals (Sweden)

    M. Elashmawy

    2017-12-01

    Full Text Available Injection process into a confined cross flow is quite important for many applications including chemical engineering and water desalination technology. The aim of this study is to investigate the performance of the injection process into a confined cross-flow of a round pipe using a single piston injection pump. A computational fluid dynamics (CFD analysis has been carried out to investigate the effect of the locations of the maximum velocity and minimum pressure on the confined cross-flow process. The jet trajectory is analyzed and related to the injection pump shaft angle of rotation during the injection duty cycle by focusing on the maximum instant injection flow of the piston action. Results indicate a low effect of the jet trajectory within the range related to the injection pump operational conditions. Constant cross-flow was used and injection flow is altered to vary the jet to line flow ratio (QR. The maximum jet trajectory exhibits low penetration inside the cross-flow. The results showed three regions of the flow ratio effect zones with different behaviors. Results also showed that getting closer to the injection port causes a significant decrease on the locations of the maximum velocity and minimum pressure.

  5. Flow-injection determination of total organic fluorine with off-line defluorination reaction on a solid sorbent bed.

    Science.gov (United States)

    Musijowski, Jacek; Trojanowicz, Marek; Szostek, Bogdan; da Costa Lima, José Luis Fontes; Lapa, Rui; Yamashita, Hiroki; Takayanagi, Toshio; Motomizu, Shoji

    2007-09-26

    Considering recent reports on widespread occurrence and concerns about perfluoroalkyl substances (PFAS) in environmental and biological systems, analysis of these compounds have gained much attention in recent years. Majority of analyte-specific methods are based on a LC/MS/MS or a GC/MS detection, however many environmental or biological studies would benefit from a total organic fluorine (TOF) determination. Presented work was aimed at developing a method for TOF determination. TOF is determined as an amount of inorganic fluoride obtained after defluorination reaction conducted off-line using sodium biphenyl reagent directly on the sorbent without elution of retained analytes. Recovered fluoride was analyzed using flow-injection system with either fluorimetric or potentiometric detection. The TOF method was tested using perfluorocarboxylic acids (PFCA), including perfluorooctanoic acid (PFOA), as model compounds. Considering low concentrations of PFAS in natural samples, solid-phase extraction as a preconcentration procedure was evaluated. Several carbon-based sorbents were tested, namely multi-wall carbon nanotubes, carbon nanofibres and activated carbon. Good sorption of all analytes was achieved and defluorination reaction was possible to carry out directly on a sorbent bed. Recoveries obtained for PFCAs, adsorbed on an activated carbon sorbent, and measured as TOF, were 99.5+/-1.7, 110+/-9.4, 95+/-26, 120+/-32, 110+/-12 for C4, C6, C8, C10 and C12-PFCA, respectively. Two flow systems that would enable the defluorination reaction and fluoride determination in a single system were designed and tested.

  6. Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture.

    Science.gov (United States)

    Cortina, Montserrat; Ecker, Christina; Calvo, Daniel; del Valle, Manuel

    2008-01-22

    An automated electronic tongue consisting of an array of potentiometric sensors and an artificial neural network (ANN) has been developed to resolve mixtures of anionic surfactants. The sensor array was formed by five different flow-through sensors for anionic surfactants, based on poly(vinyl chloride) membranes having cross-sensitivity features. Feedforward multilayer neural networks were used to predict surfactant concentrations. As a great amount of information is required for the correct modelling of the sensors response, a sequential injection analysis (SIA) system was used to automatically provide it. Dodecylsulfate (DS(-)), dodecylbenzenesulfonate (DBS(-)) and alpha-alkene sulfonate (ALF(-)) formed the three-analyte study case resolved in this work. Their concentrations varied from 0.2 to 4mM for ALF(-) and DBS(-) and from 0.2 to 5mM for DS(-). Good prediction ability was obtained with correlation coefficients better than 0.933 when the obtained values were compared with those expected for a set of 16 external test samples not used for training.

  7. Water-Level Data Analysis for the Saturated Zone Site-Scale Flow and Transport Model

    International Nuclear Information System (INIS)

    K. Rehfeldt

    2004-01-01

    This report is an updated analysis of water-level data performed to provide the ''Saturated Zone Site-Scale Flow Model'' (BSC 2004 [DIRS 170037]) (referred to as the saturated zone (SZ) site-scale flow model or site-scale SZ flow model in this report) with the configuration of the potentiometric surface, target water-level data, and hydraulic gradients for calibration of groundwater flow models. This report also contains an expanded discussion of uncertainty in the potentiometric-surface map. The analysis of the potentiometric data presented in Revision 00 of this report (USGS 2001 [DIRS 154625]) provides the configuration of the potentiometric surface, target heads, and hydraulic gradients for the calibration of the SZ site-scale flow model (BSC 2004 [DIRS 170037]). Revision 01 of this report (USGS 2004 [DIRS 168473]) used updated water-level data for selected wells through the year 2000 as the basis for estimating water-level altitudes and the potentiometric surface in the SZ site-scale flow and transport model domain based on an alternative interpretation of perched water conditions. That revision developed computer files containing: Water-level data within the model area (DTN: GS010908312332.002); A table of known vertical head differences (DTN: GS010908312332.003); and A potentiometric-surface map (DTN: GS010608312332.001) using an alternative concept from that presented by USGS (2001 [DIRS 154625]) for the area north of Yucca Mountain. The updated water-level data presented in USGS (2004 [DIRS 168473]) include data obtained from the Nye County Early Warning Drilling Program (EWDP) Phases I and II and data from Borehole USW WT-24. This document is based on Revision 01 (USGS 2004 [DIRS 168473]) and expands the discussion of uncertainty in the potentiometric-surface map. This uncertainty assessment includes an analysis of the impact of more recent water-level data and the impact of adding data from the EWDP Phases III and IV wells. In addition to being utilized

  8. The Potentiometric Titration of Filtrates from the Bachmann Process

    Science.gov (United States)

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  9. Development of flow injection analysis technique for uranium estimation

    International Nuclear Information System (INIS)

    Paranjape, A.H.; Pandit, S.S.; Shinde, S.S.; Ramanujam, A.; Dhumwad, R.K.

    1991-01-01

    Flow injection analysis is increasingly used as a process control analytical technique in many industries. It involves injection of the sample at a constant rate into a steady flowing stream of reagent and passing this mixture through a suitable detector. This paper describes the development of such a system for the analysis of uranium (VI) and (IV) and its gross gamma activity. It is amenable for on-line or automated off-line monitoring of uranium and its activity in process streams. The sample injection port is suitable for automated injection of radioactive samples. The performance of the system has been tested for the colorimetric response of U(VI) samples at 410 nm in the range of 35 to 360mg/ml in nitric acid medium using Metrohm 662 Photometer and a recorder as detector assembly. The precision of the method is found to be better than +/- 0.5%. This technique with certain modifications is used for the analysis of U(VI) in the range 0.1-3mg/ailq. by alcoholic thiocynate procedure within +/- 1.5% precision. Similarly the precision for the determination of U(IV) in the range 15-120 mg at 650 nm is found to be better than 5%. With NaI well-type detector in the flow line, the gross gamma counting of the solution under flow is found to be within a precision of +/- 5%. (author). 4 refs., 2 figs., 1 tab

  10. Are Flow Injection-based Approaches Suitable for Automated Handling of Solid Samples?

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Cerdà, Victor

    Flow-based approaches were originally conceived for liquid-phase analysis, implying that constituents in solid samples generally had to be transferred into the liquid state, via appropriate batch pretreatment procedures, prior to analysis. Yet, in recent years, much effort has been focused...... electrolytic or aqueous leaching, on-line dialysis/microdialysis, in-line filtration, and pervaporation-based procedures have been successfully implemented in continuous flow/flow injection systems. In this communication, the new generation of flow analysis, including sequential injection, multicommutated flow.......g., soils, sediments, sludges), and thus, ascertaining the potential mobility, bioavailability and eventual impact of anthropogenic elements on biota [2]. In this context, the principles of sequential injection-microcolumn extraction (SI-MCE) for dynamic fractionation are explained in detail along...

  11. Retro-review of flow injection analysis

    DEFF Research Database (Denmark)

    Ruzicka, Jaromir; Hansen, Elo Harald

    2008-01-01

    It is indeed unusual for authors to review their own monograph – J. Ruzicka, E.H. Hansen, Flow Injection Analysis, 2nd Edition, Wiley, Chichester, West Sussex, UK, 1988. – and even more so if the book was published 20 years ago. Yet such an exercise might yield a perspective on the progress of an...

  12. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  13. Water-Level Data Analysis for the Saturated Zone Site-Scale Flow and Transport Model

    Energy Technology Data Exchange (ETDEWEB)

    K. Rehfeldt

    2004-10-08

    This report is an updated analysis of water-level data performed to provide the ''Saturated Zone Site-Scale Flow Model'' (BSC 2004 [DIRS 170037]) (referred to as the saturated zone (SZ) site-scale flow model or site-scale SZ flow model in this report) with the configuration of the potentiometric surface, target water-level data, and hydraulic gradients for calibration of groundwater flow models. This report also contains an expanded discussion of uncertainty in the potentiometric-surface map. The analysis of the potentiometric data presented in Revision 00 of this report (USGS 2001 [DIRS 154625]) provides the configuration of the potentiometric surface, target heads, and hydraulic gradients for the calibration of the SZ site-scale flow model (BSC 2004 [DIRS 170037]). Revision 01 of this report (USGS 2004 [DIRS 168473]) used updated water-level data for selected wells through the year 2000 as the basis for estimating water-level altitudes and the potentiometric surface in the SZ site-scale flow and transport model domain based on an alternative interpretation of perched water conditions. That revision developed computer files containing: Water-level data within the model area (DTN: GS010908312332.002); A table of known vertical head differences (DTN: GS010908312332.003); and A potentiometric-surface map (DTN: GS010608312332.001) using an alternative concept from that presented by USGS (2001 [DIRS 154625]) for the area north of Yucca Mountain. The updated water-level data presented in USGS (2004 [DIRS 168473]) include data obtained from the Nye County Early Warning Drilling Program (EWDP) Phases I and II and data from Borehole USW WT-24. This document is based on Revision 01 (USGS 2004 [DIRS 168473]) and expands the discussion of uncertainty in the potentiometric-surface map. This uncertainty assessment includes an analysis of the impact of more recent water-level data and the impact of adding data from the EWDP Phases III and IV wells. In

  14. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  15. SHORT COMMUNICATION POTENTIOMETRIC DETERMINATION ...

    African Journals Online (AJOL)

    a

    SHORT COMMUNICATION. POTENTIOMETRIC DETERMINATION OF K+ IONS USING A K+-SELECTIVE. ELECTRODE WITH MACROCYCLIC LIQUID MEMBRANE. Cezar Spinu*, Marian Isvoranu, Maria Pleniceanu and Cristian Tigae. Faculty of Chemistry, University of Craiova, A.I. Cuza 13, Craiova, Romania. (Received ...

  16. Charge Injection and Current Flow in Organic Light Emitting Diodes

    Science.gov (United States)

    Smith, D. L.; Davids, P. S.; Heller, C. M.; Crone, B. K.; Campbell, I. H.; Barashkov, N. N.; Ferraris, J. P.

    1997-03-01

    We present a comparison between device model calculations and current-voltage measurements for a series of organic LED structures. The Schottky energy barrier of an injecting contact is systematically varied by changing the metal used to form that contact. The current-voltage characteristics of the structures are described using a device model that considers charge injection, transport and space charge effects in the low mobility organic material. Charge injection into the organic material is controlled by the Schottky energy barrier of the metal/organic contact. For Schottky energy barriers greater than about 0.4 eV injection into the organic material is the principal limitation to current flow. In this regime the net injected charge density is relatively small, the electric field in the structure is nearly uniform, and space charge effects are not important. For smaller energy barriers relatively large charge densities are injected into the organic material and space charge effects become the dominant limit to current flow. The measured current-voltage characteristics are quantitatively described by the device model using Schottky barrier values independently determined by internal photoemission and electroabsorption measurements.

  17. Potentiometric Surfaces in the Springfield Plateau and Ozark Aquifers of Northwestern Arkansas, Southeastern Kansas, Southwestern Missouri, and Northeastern Oklahoma, 2006

    Science.gov (United States)

    Gillip, Jonathan A.; Czarnecki, John B.; Mugel, Douglas N.

    2008-01-01

    generally flows to the west in the study area, and to surface features (lakes, rivers, and springs) particularly in the south and east of the study area where the Springfield Plateau aquifer is closest to land surface. The potentiometric-surface map of the Ozark aquifer indicates a maximum measured water-level altitude of 1,303 feet in the study area at a well in Washington County, Arkansas, and a minimum measured water-level altitude of 390 feet in Ottawa County, Oklahoma. The water in the Ozark aquifer generally flows to the northwest in the northern part of the study area and to the west in the remaining study area. Cones of depression occur in Barry, Barton, Cedar, Jasper, Lawrence, McDonald, Newton, and Vernon Counties in Missouri, Cherokee and Crawford Counties in Kansas, and Craig and Ottawa Counties in Oklahoma. These cones of depression are associated with municipal supply wells. The flow directions, based on both potentiometric-surface maps, generally agree with flow directions indicated by previous studies.

  18. Carbon Nanotubes-Based Potentiometric Bio-Sensors for Determination of Urea

    Directory of Open Access Journals (Sweden)

    Ewa Jaworska

    2015-07-01

    Full Text Available The possibility of using disposable plastic-carbon potentiometric sensors as enzyme biosensors was examined. Urease enzyme was immobilized on poly(vinyl chloride based H+- or NH4+-selective membranes using cellulose acetate. This approach has resulted in a potentiometric response on changing the pH of the solution or NH4+ ion content due to an enzymatic reaction that occurs between urease and urea. Both types of potentiometric biosensors for urea were characterized by good analytical parameters as high sensitivity and fast response time.

  19. The Co-axial Flow of Injectable Solid Hydrogels with Encapsulated Cells

    Science.gov (United States)

    Stewart, Brandon; Pochan, Darrin; Sathaye, Sameer

    2013-03-01

    Hydrogels are quickly becoming an important biomaterial that can be used for the safe, localized injection of cancer drugs, the injection of stem cells into areas of interest or other biological applications. Our peptides can be self-assembled in a syringe where they form a gel, sheared by injection and, once in the body, immediately reform a localized pocket of stiff gel. My project has been designed around looking at the possibility of having a co-axial strand, in which one gel can surround another. This co-axial flow can be used to change the physical properties of our gel during injection, such as stiffening our gel using hyaluronic acid or encapsulating cells in the gel and surrounding the gel with growth medium or other biological factors. Rheology on hyaluron stiffened gels and cells encapsulated in gels was performed for comparison to the results from co-axial flow. Confocal microscopy was used to examine the coaxial gels after flow and to determine how the co-axial nature of the gels is affected by the concentration of peptide.

  20. Manual and Flow-Injection Detection/Quantification of Polyquaterniums via Fully Reversible Polyion-Sensitive Polymeric Membrane-Based Ion-Selective Electrodes.

    Science.gov (United States)

    Ferguson, Stephen A; Meyerhoff, Mark E

    2017-10-27

    The detection of four different polyquaterniums (PQs) using a fully reversible potentiometric polyion sensor in three different detection modes is described. The polyion sensing "pulstrodes" serve as the detector for direct dose-response experiments, beaker titrations, and in a flow-injection analysis (FIA) system. Direct polycation response toward PQ-2, PQ-6, PQ-10, and poly(2-methacryloxyethyltrimethylammonium) chloride (PMETAC) yields characteristic information about each PQ species (e.g., relative charge densities, etc.) via syringe pump addition of each PQ species to a background electrolyte solution. Quantitative titrations are performed using a syringe pump to deliver heparin as the polyanion titrant to quantify all four PQs at μg/mL levels. Both the direct and indirect methods incorporate the use of a three-electrode system including counter, double junction reference, and working electrodes. The working electrode possesses a plasticized poly(vinyl chloride) (PVC) membrane containing the neutral lipophilic salt of dinonylnaphthalenesulfonate (DNNS - ) tridodecylmethylammonium (TDMA + ). Further, the titration method is shown to be useful to quantify PQ-6 levels in recreational swimming pool water collected in Ann Arbor, MI. Finally, a FIA system equipped with a pulstrode detector is used to demonstrate the ability to potentially quantify PQ levels via a more streamlined and semiautomated testing platform.

  1. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    OpenAIRE

    Jaroon Jakmunee

    2008-01-01

    A stopped-flow injection (FI) spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product z...

  2. Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography

    Science.gov (United States)

    Dumanli, Rukiye; Attar, Azade; Erci, Vildan; Isildak, Ibrahim

    2016-01-01

    A microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion- and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na+), potassium (K+), ammonium (NH4+), chloride (Cl−) and nitrate (NO3−) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixed-bed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 µM for the anions and 0.3 to 3.0 µM for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples. PMID:26786906

  3. Sensitive flow-injection spectrophotometric analysis of bromopride

    Science.gov (United States)

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  4. Flow Injection and Atomic Absorption Spectrometry (FI-AAS) -

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    One of the advantages of the flow injection (FI) concept is that it is compatible with virtually all detection techniques. Being a versatile vehicle for enhancing the performance of the individual detection devices, the most spectacular results have possibly been obtained in conjunction with atomic...... the point of sample injection/introduction to the point of detection. Hence, in FI-fAAS this feature allows not only to obtain improved repeatability but also improved accuracy, and because the wash to sample ratio is high it permits the handling of samples with elevated salt contents - which...

  5. Flow Injection/Sequential Injection Analysis Systems: Potential Use as Tools for Rapid Liver Diseases Biomarker Study

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Flow injection/sequential injection analysis (FIA/SIA systems are suitable for carrying out automatic wet chemical/biochemical reactions with reduced volume and time consumption. Various parts of the system such as pump, valve, and reactor may be built or adapted from available materials. Therefore the systems can be at lower cost as compared to other instrumentation-based analysis systems. Their applications for determination of biomarkers for liver diseases have been demonstrated in various formats of operation but only a few and limited types of biomarkers have been used as model analytes. This paper summarizes these applications for different types of reactions as a guide for using flow-based systems in more biomarker and/or multibiomarker studies.

  6. Limitations of potentiometric oxygen sensors operating at low oxygen levels

    DEFF Research Database (Denmark)

    Lund, Anders; Jacobsen, Torben; Hansen, Karin Vels

    2011-01-01

    The electrochemical processes that limit the range of oxygen partial pressures in which potentiometric oxygen sensors can be used, were analysed using a theoretical and an experimental approach. Electrochemical impedance spectroscopy was performed on porous Pt/yttria stabilised zirconia (YSZ......) electrodes between 10−6 and 0.2 bar and at temperatures between 500 and 950 °C. The flow of oxide ions and electron holes through a sensor cell, with a YSZ electrolyte, were calculated under similar conditions. The oxygen permeation of the sensor cell was insignificant at an oxygen partial pressure of 10......−6 bar for an inlet flow rate higher than 2 L h−1 between 600 and 800 °C. The polarisation resistance measured between 10−6 and 10−4 bar was found to be inversely proportional to the oxygen partial pressure, nearly temperature independent and inversely proportional to the inlet gas flow rate, which shows...

  7. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    Science.gov (United States)

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  8. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level

    International Nuclear Information System (INIS)

    Sahoo, P.; Ananthanarayanan, R.; Malathi, N.; Rajiniganth, M.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 μg L -1 levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L -1 levels, with modification in methodology for accurate detection of end point even at 10.0 μg L -1 levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 μg L -1 O 2 . Finally, several water samples containing dissolved oxygen from mg L -1 to μg L -1 levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 μg L -1 O 2 level is 0.14 (n = 5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 μg L -1 levels.

  9. Interaction of Liquid Film Flow of Direct Vessel Injection Under the Cross Directional Gas Flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness and a hydraulic jump in the film flow and boundaries of the film flow. It was found that CFD analysis results without surface tension model showed some difference with the data in surface tension dominated flow region. For the interaction between a liquid film and gas shear flow, CFD results make a good agreement with the real liquid film dynamics in the case of low film Reynolds number or low Weber number flow. In the 1/20 scaled plate type experiment and simulation, the deformed spreading profile results seem to accord with each other at the relatively low We and Re regime.

  10. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.

  11. Cross-flow analysis of injection wells in a multilayered reservoir

    Directory of Open Access Journals (Sweden)

    Mohammadreza Jalali

    2016-09-01

    Natural and forced cross-flow is modeled for some injection wells in an oil reservoir located at North Sea. The solution uses a transient implicit finite difference approach for multiple sand layers with different permeabilities separated by impermeable shale layers. Natural and forced cross-flow rates for each reservoir layer during shut-in are calculated and compared with different production logging tool (PLT measurements. It appears that forced cross-flow is usually more prolonged and subject to a higher flow rate when compared with natural cross-flow, and is thus worthy of more detailed analysis.

  12. The effects of arbitrary injection angle and flow conditions on venturi-jet mixer

    Directory of Open Access Journals (Sweden)

    Sundararaj S.

    2012-01-01

    Full Text Available This paper describes the effect of jet injection angle, cross flow Reynolds number and velocity ratio on entrainment and mixing of jet with incompressible cross flow in venturi-jet mixer. Five different jet injection angles 45o, 60o, 90o, 125o, 135o are tested to evaluate the entrainment of jet and mixing performances of the mixer. Tracer concentration along the downstream of the jet injection, cross flow velocity, jet velocity and pressure drop across the mixer are determined experimentally to characterize the mixing performance of the mixer. The experiments show that the performance of a venturi-jet-mixer substantially improves at high injection angle and can be augmented still by increasing velocity ratio. The jet deflects much and penetrates less in the cross flow as the cross flow Reynolds number is increased. The effect could contribute substantially to the better mixing index with moderate pressure drop. Normalized jet profile, concentration decay, jet velocity profile are computed from equations of conservation of mass, momentum and concentration written in natural co-ordinate systems. The comparison between the experimental and numerical results confirms the accuracy of the simulations. Correlations for jet trajectory and entrainment ratio of the mixer are obtained by multivariate-linear regression analysis using power law.

  13. Flow regime analysis for fluid injection into a confined aquifer: implications for CO2 sequestration

    Science.gov (United States)

    Guo, B.; Zheng, Z.; Celia, M. A.; Stone, H.

    2015-12-01

    Carbon dioxide injection into a confined saline aquifer may be modeled as an axisymmetric two-phase flow problem. Assuming the two fluids segregate in the vertical direction due to strong buoyancy, and neglecting capillary pressure and miscibility, the lubrication approximation leads to a nonlinear advection-diffusion equation that describes the evolution of the sharp fluid-fluid interface. The flow behaviors in the system are controlled by two dimensionless groups: M, the viscosity ratio of the displaced fluid relative to injected fluid, and Γ , the gravity number, which represents the relative importance of buoyancy and fluid injection. Four different analytical solutions can be derived as the asymptotic approximations, representing specific values of the parameter pairs. The four solutions correspond to: (1) Γ 1; and (4) Γ >> 1, any M values. The first two of these solutions are new, while the third corresponds to the solution of Nordbotten and Celia (2006) for confined injections and the fourth corresponds to the solution of (Lyle et al., 2005) for gravity currents in an unconfined aquifer. Overall, the various axisymmetric flows can be summarized in a Γ-M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime (Fig. 1). Data from a number of CO2 injection sites around the world can be used to compute the two dimensionless groups Γ and M associated with each injection. When plotted on the regime diagram, these values show the flow behavior for each injection and how the values vary from site to site. For all the CO2 injections, M is always larger than 1, while Γ can range from 0.01 up to 100. The pairs of (Γ, M) with lower Γ values correspond to solution (3), while the ones with higher Γ values can move up to the intermediate regime and the flow regime for solution (4). The higher values of Γ correspond to pilot-scale injections with low injection rates; most industrial-scale injection

  14. Chemical sensors and the development of potentiometric methods for liquid media analysis

    International Nuclear Information System (INIS)

    Vlasov, Yu.G.; Kolodnikov, V.V.; Ermolenko, Yu.E.; Mikhajlova, S.S.

    1996-01-01

    Aspects of applying indirect potentiometric determination to chemical analysis are considered. Among them are the standard and modified addition and subtraction methods, the multiple addition method, and potentiometric titration using ion-selective electrodes as indicators. These methods significantly extend the capabilities of ion-selective potentiometric analysis. Conditions for the applicability of the above-mentioned methods to various samples (Cd, REE, Th, iodides and others) are discussed using all available ion-selective electrodes as examples. 162 refs., 2 figs., 5 tabs

  15. Water-Level Data Analysis for the Saturated Zone Site-Scale Flow and Transport Model

    International Nuclear Information System (INIS)

    Tucci, P.

    2001-01-01

    This Analysis/Model Report (AMR) documents an updated analysis of water-level data performed to provide the saturated-zone, site-scale flow and transport model (CRWMS M and O 2000) with the configuration of the potentiometric surface, target water-level data, and hydraulic gradients for model calibration. The previous analysis was presented in ANL-NBS-HS-000034, Rev 00 ICN 01, Water-Level Data Analysis for the Saturated Zone Site-Scale Flow and Transport Model (USGS 2001). This analysis is designed to use updated water-level data as the basis for estimating water-level altitudes and the potentiometric surface in the SZ site-scale flow and transport model domain. The objectives of this revision are to develop computer files containing (1) water-level data within the model area (DTN: GS010908312332.002), (2) a table of known vertical head differences (DTN: GS0109083 12332.003), and (3) a potentiometric-surface map (DTN: GS010608312332.001) using an alternate concept from that presented in ANL-NBS-HS-000034, Rev 00 ICN 01 for the area north of Yucca Mountain. The updated water-level data include data obtained from the Nye County Early Warning Drilling Program (EWDP) and data from borehole USW WT-24. In addition to being utilized by the SZ site-scale flow and transport model, the water-level data and potentiometric-surface map contained within this report will be available to other government agencies and water users for ground-water management purposes. The potentiometric surface defines an upper boundary of the site-scale flow model, as well as provides information useful to estimation of the magnitude and direction of lateral ground-water flow within the flow system. Therefore, the analysis documented in this revision is important to SZ flow and transport calculations in support of total system performance assessment

  16. Determination of Optimal Flow Paths for Safety Injection According to Accident Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kwae Hwan; Kim, Ju Hyun; Kim, Dong Yeong; Na, Man Gyun [Chosun Univ., Gwangju (Korea, Republic of); Hur, Seop; Kim, Changhwoi [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In case severe accidents happen, major safety parameters of nuclear reactors are rapidly changed. Therefore, operators are unable to respond appropriately. This situation causes the human error of operators that led to serious accidents at Chernobyl. In this study, we aimed to develop an algorithm that can be used to select the optimal flow path for cold shutdown in serious accidents, and to recover an NPP quickly and efficiently from the severe accidents. In order to select the optimal flow path, we applied a Dijkstra algorithm. The Dijkstra algorithm is used to find the path of minimum total length between two given nodes and needs a weight (or length) matrix. In this study, the weight between nodes was calculated from frictional and minor losses inside pipes. That is, the optimal flow path is found so that the pressure drop between a starting node (water source) and a destination node (position that cooling water is injected) is minimized. In case a severe accident has happened, if we inject cooling water through the optimized flow path, then the nuclear reactor will be safely and effectively returned into the cold shutdown state. In this study, we have analyzed the optimal flow paths for safety injection as a preliminary study for developing an accident recovery system. After analyzing the optimal flow path using the Dijkstra algorithm, and the optimal flow paths were selected by calculating the head loss according to path conditions.

  17. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  18. Potentiometric-level monitoring program: Mississippi and Louisiana. Annual status report for fiscal year 1984

    International Nuclear Information System (INIS)

    1986-07-01

    Potentiometric-level data presented in this report were collected from October 1983 through September 1984 at 79 wells in Mississippi and Louisiana. These wells are located near Richton and Cypress Creek Domes in Mississippi and Vacherie Dome in Louisiana. Fourteen wells were added to the program during this period. Two of these wells were not measurable. Two wells previously unmeasurable were located and measured. One well was destroyed during military maneuvers in the area. Analysis of the data indicated minimal, if any, change in potentiometric levels during the past year in the Citronelle, Hattiesburg, Cockfield, Sparta, and Wilcox Formations in Mississippi. A continuing decline in potentiometric levels, ranging from 0.3 to 0.6 foot per year, occurred in the wells screened in the caprock at Richton and Cypress Creek Domes. The Catahoula Formation experienced a continuing decline in potentiometric levels of about 2 feet per year. Two wells in the Cook Mountain Formation showed a continuing rise in potentiometric levels ranging from 8 to 30 ft during the past fiscal year. Wells screened in the Austin Formation in Louisiana showed a fall in potentiometric levels of 2 to 3 ft over the past fiscal year. Other formations in Louisiana generally showed no change in potentiometric levels over the past year. 26 refs., 2 figs., 3 tabs

  19. Flow rate dependent extra-column variance from injection in capillary liquid chromatography.

    Science.gov (United States)

    Aggarwal, Pankaj; Liu, Kun; Sharma, Sonika; Lawson, John S; Dennis Tolley, H; Lee, Milton L

    2015-02-06

    Efficiency and resolution in capillary liquid chromatography (LC) can be significantly affected by extra-column band broadening, especially for isocratic separations. This is particularly a concern in evaluating column bed structure using non-retained test compounds. The band broadening due to an injector supplied with a commercially available capillary LC system was characterized from experimental measurements. The extra-column variance from the injection valve was found to have an extra-column contribution independent of the injection volume, showing an exponential dependence on flow rate. The overall extra-column variance from the injection valve was found to vary from 34 to 23 nL. A new mathematical model was derived that explains this exponential contribution of extra-column variance on chromatographic performance. The chromatographic efficiency was compromised by ∼130% for a non-retained analyte because of injection valve dead volume. The measured chromatographic efficiency was greatly improved when a new nano-flow pumping system with integrated injection valve was used. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Re-injection feasibility study of fracturing flow-back fluid in shale gas mining

    Science.gov (United States)

    Kang, Dingyu; Xue, Chen; Chen, Xinjian; Du, Jiajia; Shi, Shengwei; Qu, Chengtun; Yu, Tao

    2018-02-01

    Fracturing flow-back fluid in shale gas mining is usually treated by re-injecting into formation. After treatment, the fracturing flow-back fluid is injected back into the formation. In order to ensure that it will not cause too much damage to the bottom layer, feasibility evaluations of re-injection of two kinds of fracturing fluid with different salinity were researched. The experimental research of the compatibility of mixed water samples based on the static simulation method was conducted. Through the analysis of ion concentration, the amount of scale buildup and clay swelling rate, the feasibility of re-injection of different fracturing fluid were studied. The result shows that the swelling of the clay expansion rate of treated fracturing fluid is lower than the mixed water of treated fracturing fluid and the distilled water, indicating that in terms of clay expansion rate, the treated fracturing flow-back fluid is better than that of water injection after re-injection. In the compatibility test, the maximum amount of fouling in the Yangzhou oilfield is 12mg/L, and the maximum value of calcium loss rate is 1.47%, indicating that the compatibility is good. For the fracturing fluid with high salinity in the Yanchang oilfield, the maximum amount of scaling is 72mg/L, and the maximum calcium loss rate is 3.50%, indicating that the compatibility is better.

  1. Rapid dual-injection single-scan 13N-ammonia PET for quantification of rest and stress myocardial blood flows

    International Nuclear Information System (INIS)

    Rust, T C; DiBella, E V R; McGann, C J; Christian, P E; Hoffman, J M; Kadrmas, D J

    2006-01-01

    Quantification of myocardial blood flows at rest and stress using 13 N-ammonia PET is an established method; however, current techniques require a waiting period of about 1 h between scans. The objective of this study was to test a rapid dual-injection single-scan approach, where 13 N-ammonia injections are administered 10 min apart during rest and adenosine stress. Dynamic PET data were acquired in six human subjects using imaging protocols that provided separate single-injection scans as gold standards. Rest and stress data were combined to emulate rapid dual-injection data so that the underlying activity from each injection was known exactly. Regional blood flow estimates were computed from the dual-injection data using two methods: background subtraction and combined modelling. The rapid dual-injection approach provided blood flow estimates very similar to the conventional single-injection standards. Rest blood flow estimates were affected very little by the dual-injection approach, and stress estimates correlated strongly with separate single-injection values (r = 0.998, mean absolute difference = 0.06 ml min -1 g -1 ). An actual rapid dual-injection scan was successfully acquired in one subject and further demonstrates feasibility of the method. This study with a limited dataset demonstrates that blood flow quantification can be obtained in only 20 min by the rapid dual-injection approach with accuracy similar to that of conventional separate rest and stress scans. The rapid dual-injection approach merits further development and additional evaluation for potential clinical use

  2. Flow Injection Analysis: A Revolution in Modern Analytical Chemistry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    A review is made of the fundamentals of Flow Injection Analysis (FIA), and the versatility and applicability of this analytical concept is demonstrated by a series of examples, comprizing the use of different types of FIA-manifolds and various detection devices (optical and electrochemical...

  3. Comparison of Potentiometric and Gravimetric Methods for Determination of O/U Ratio

    International Nuclear Information System (INIS)

    Farida; Windaryati, L; Putro Kasino, P

    1998-01-01

    Comparison of determination O/U ratio by using potentiometric and gravimetric methods has been done. Those methods are simple, economical and having high precision and accuracy. Determination O/U ratio for UO 2 powder using potentiometric is carried out by adopting the davies-gray method. This technique is based on the redox reaction of uranium species such as U(IV) and U(VI). In gravimetric method,the UO 2 power as a sample is calcined at temperature of 900 C, and the weight of the sample is measured after calcination process. The t-student test show that there are no different result significantly between those methods. However, for low concentration in the sample the potentiometric method has a highed precision and accuracy compare to the gravimetric method. O/U ratio obtained is 2.00768 ± 0,00170 for potentiometric method 2.01089 ± 0,02395 for gravimetric method

  4. Enhancement of melting heat transfer of ice slurries by an injection flow in a rectangular cross sectional horizontal duct

    International Nuclear Information System (INIS)

    Fujii, Kota; Yamada, Masahiko

    2013-01-01

    Ice slurries are now commonly used as cold thermal storage materials, and have the potential to be applied to other engineering fields such as quenching metals to control properties, emergency cooling systems, and preservation of food and biomaterials at low temperatures. Although ice slurries have been widely utilized because of their high thermal storage densities, previous studies have revealed that the latent heat of ice particles is not completely released on melting because of insufficient contact between the ice particles and a heated surface. In this study, an injection flow that was bifurcated from the main flow of an ice slurry was employed to promote melting heat transfer of ice particles on a horizontal heated surface. The effects of injection angle and injection flow rate on local heat transfer coefficients and heat transfer coefficient ratios were determined experimentally. The results show that from two to three times higher heat transfer coefficients can be obtained by using large injection flow rates and injection angles. However, low injection angles improved the utilization rate of the latent heat of ice near the injection point by approximately a factor of two compared to that without injection. -- Highlights: • Melting of ice slurries were enhanced by the injection under constant total flow rate. • Contribution of ice particles and their latent heat to heat transfer was investigated. • Effect of velocity ratio of injection to that of main flow was examined. • Effect of the angle of injection flow to the main flow was also examined. • Appropriate conditions for the use of latent heat of ice and heat transfer did not coincide

  5. Liquid sprays and flow studies in the direct-injection diesel engine under motored conditions

    Science.gov (United States)

    Nguyen, Hung Lee; Carpenter, Mark H.; Ramos, Juan I.; Schock, Harold J.; Stegeman, James D.

    1988-01-01

    A two dimensional, implicit finite difference method of the control volume variety, a two equation model of turbulence, and a discrete droplet model were used to study the flow field, turbulence levels, fuel penetration, vaporization, and mixing in diesel engine environments. The model was also used to study the effects of engine speed, injection angle, spray cone angle, droplet distribution, and intake swirl angle on the flow field, spray penetration and vaporization, and turbulence in motored two-stroke diesel engines. It is shown that there are optimum conditions for injection, which depend on droplet distribution, swirl, spray cone angle, and injection angle. The optimum conditions result in good spray penetration and vaporization and in good fuel mixing. The calculation presented clearly indicates that internal combustion engine models can be used to assess, at least qualitatively, the effects of injection characteristics and engine operating conditions on the flow field and on the spray penetration and vaporization in diesel engines.

  6. Numerical investigation of the air injection effect on the cavitating flow in Francis hydro turbine

    Science.gov (United States)

    Chirkov, D. V.; Shcherbakov, P. K.; Cherny, S. G.; Skorospelov, V. A.; Turuk, P. A.

    2017-09-01

    At full and over load operating points, some Francis turbines experience strong self-excited pressure and power oscillations. These oscillations are occuring due to the hydrodynamic instability of the cavitating fluid flow. In many cases, the amplitude of such pulsations may be reduced substantially during the turbine operation by the air injection/ admission below the runner. Such an effect is investigated numerically in the present work. To this end, the hybrid one-three-dimensional model of the flow of the mixture "liquid-vapor" in the duct of a hydroelectric power station, which was proposed previously by the present authors, is augmented by the second gaseous component — the noncondensable air. The boundary conditions and the numerical method for solving the equations of the model are described. To check the accuracy of computing the interface "liquid-gas", the numerical method was applied at first for solving the dam break problem. The algorithm was then used for modeling the flow in a hydraulic turbine with air injection below the runner. It is shown that with increasing flow rate of the injected air, the amplitude of pressure pulsations decreases. The mechanism of the flow structure alteration in the draft tube cone has been elucidated, which leads to flow stabilization at air injection.

  7. Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol.

    Science.gov (United States)

    Felix, Fabiana S; Brett, Christopher M A; Angnes, Lúcio

    2008-06-30

    Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5x10(-7) to 3.5x10(-4) mol L(-1), in 0.1 mol L(-1) sulfuric acid electrolyte, as well as high sensitivity, 0.110 Amol(-1) L cm(-2) at the optimized flow rate. A detection limit of 7.6x10(-8) mol L(-1) and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 microL and a flow rate of 2.0 mL min(-1). The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0x10(-6) and 6.0x10(-5) mol L(-1) ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis.

  8. Numerical Simulation of Polymer Injection in Turbulent Flow Past a Circular Cylinder

    KAUST Repository

    Richter, David; Shaqfeh, Eric S. G.; Iaccarino, Gianluca

    2011-01-01

    Using a code developed to compute high Reynolds number viscoelastic flows, polymer injection from the upstream stagnation point of a circular cylinder is modeled at Re = 3900. Polymer stresses are represented using the FENE-P constitutive equations. By increasing polymer injection rates within realistic ranges, significant near wake stabilization is observed. Rather than a turbulent detached shear layer giving way to a chaotic primary vortex (as seen in Newtonian flows at high Re), a much more coherent primary vortex is shed, which possesses an increased core pressure as well as a reduced level of turbulent energy. © 2011 American Society of Mechanical Engineers.

  9. Detailed evaluation of the natural circulation mass flow rate of water propelled by using an air injection

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Jae-Cheol; Hong, Seong-Wan; Kim, Sang-Baik

    2008-01-01

    One-dimensional (1D) air-water two-phase natural circulation flow in the thermohydraulic evaluation of reactor cooling mechanism by external self-induced flow - one-dimensional' (THERMES-1D) experiment has been verified and evaluated by using the RELAP5/MOD3 computer code. Experimental results on the 1D natural circulation mass flow rate of water propelled by using an air injection have been evaluated in detail. The RELAP5 results have shown that an increase in the air injection rate to 50% of the total heat flux leads to an increase in the water circulation mass flow rate. However, an increase in the air injection rate from 50 to 100% does not affect the water circulation mass flow rate, because of the inlet area condition. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it has no influence on the local pressure. An increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not have an influence on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. (author)

  10. Potentiometric titration of metal ions in ethanol.

    Science.gov (United States)

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  11. Decompositions of injection patterns for nodal flow allocation in renewable electricity networks

    Science.gov (United States)

    Schäfer, Mirko; Tranberg, Bo; Hempel, Sabrina; Schramm, Stefan; Greiner, Martin

    2017-08-01

    The large-scale integration of fluctuating renewable power generation represents a challenge to the technical and economical design of a sustainable future electricity system. In this context, the increasing significance of long-range power transmission calls for innovative methods to understand the emerging complex flow patterns and to integrate price signals about the respective infrastructure needs into the energy market design. We introduce a decomposition method of injection patterns. Contrary to standard flow tracing approaches, it provides nodal allocations of link flows and costs in electricity networks by decomposing the network injection pattern into market-inspired elementary import/export building blocks. We apply the new approach to a simplified data-driven model of a European electricity grid with a high share of renewable wind and solar power generation.

  12. Geostatistical and adjoint sensitivity techniques applied to a conceptual model of ground-water flow in the Paradox Basin, Utah

    International Nuclear Information System (INIS)

    Metcalfe, D.E.; Campbell, J.E.; RamaRao, B.S.; Harper, W.V.; Battelle Project Management Div., Columbus, OH)

    1985-01-01

    Sensitivity and uncertainty analysis are important components of performance assessment activities for potential high-level radioactive waste repositories. The application of geostatistical and adjoint sensitivity techniques to aid in the calibration of an existing conceptual model of ground-water flow is demonstrated for the Leadville Limestone in Paradox Basin, Utah. The geostatistical method called kriging is used to statistically analyze the measured potentiometric data for the Leadville. This analysis consists of identifying anomalous data and data trends and characterizing the correlation structure between data points. Adjoint sensitivity analysis is then performed to aid in the calibration of a conceptual model of ground-water flow to the Leadville measured potentiometric data. Sensitivity derivatives of the fit between the modeled Leadville potentiometric surface and the measured potentiometric data to model parameters and boundary conditions are calculated by the adjoint method. These sensitivity derivatives are used to determine which model parameter and boundary condition values should be modified to most efficiently improve the fit of modeled to measured potentiometric conditions

  13. Modeling and flow analysis of pure nylon polymer for injection molding process

    International Nuclear Information System (INIS)

    Nuruzzaman, D M; Kusaseh, N; Basri, S; Hamedon, Z; Oumer, A N

    2016-01-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured. (paper)

  14. Modeling and flow analysis of pure nylon polymer for injection molding process

    Science.gov (United States)

    Nuruzzaman, D. M.; Kusaseh, N.; Basri, S.; Oumer, A. N.; Hamedon, Z.

    2016-02-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured.

  15. Open-Source Low-Cost Wireless Potentiometric Instrument for pH Determination Experiments

    Science.gov (United States)

    Jin, Hao; Qin, Yiheng; Pan, Si; Alam, Arif U.; Dong, Shurong; Ghosh, Raja; Deen, M. Jamal

    2018-01-01

    pH determination is an essential experiment in many chemistry laboratories. It requires a potentiometric instrument with extremely low input bias current to accurately measure the voltage between a pH sensing electrode and a reference electrode. In this technology report, we propose an open-source potentiometric instrument for pH determination…

  16. Study of process parameters on two phase flow agitated by top blowing lance injection into a bath

    Energy Technology Data Exchange (ETDEWEB)

    Xia Jiliang; Ahokainen, T.; Holappa, L.

    1998-12-31

    Numerical investigation has been carried out for two phase flow in a bath agitated by top blowing lance injection. Eulerian two phase flow model is used. Lance immersion depth, injection gas flow rate, nozzle diameter, and bubble size have been systematically changed to examine their influence on the flow characteristics in the bath. It is found that there appear three typical flow patterns: one-vortex, two-vortex, and three-vortex type, with changing the injection gas flow rate or/and the nozzle diameter at moderate lance immersion depth. Predicted velocities are in a good agreement with Iguchi et al.`s experimental data and the main findings are also consistent with the measurements and observations of Chatterjee and Hsiao and Lehner. (orig.) 24 refs. Computational Fluid Dynamics Technology Programme

  17. Highly sensitive covalently functionalized light-addressable potentiometric sensor for determination of biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Jintao [School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Guangxi Experiment Center of Information Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Guan, Mingyuan; Huang, Guoyin; Qiu, Hengming; Chen, Zhengcheng [School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Li, Guiyin, E-mail: liguiyin01@163.com [School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Guangxi Experiment Center of Information Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Huang, Yong, E-mail: huangyong503@126.com [School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Guangxi Experiment Center of Information Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China)

    2016-06-01

    A biomarker is related to the biological status of a living organism and shows great promise for the early prediction of a related disease. Herein we presented a novel structured light-addressable potentiometric sensor (LAPS) for the determination of a model biomarker, human immunoglobulin G (hIgG). In this system, the goat anti-human immunoglobulin G antibody was used as recognition element and covalently immobilized on the surface of light-addressable potentiometric sensor chip to capture human immunoglobulin G. Due to the light addressable capability of light-addressable potentiometric sensor, human immunoglobulin G dissolved in the supporting electrolyte solution can be detected by monitoring the potential shifts of the sensor. In order to produce a stable photocurrent, the laser diode controlled by field-programmable gate array was used as the light emitter to drive the light-addressable potentiometric sensor. A linear correlation between the potential shift response and the concentration of human immunoglobulin G was achieved and the corresponding regression equation was ΔV (V) = 0.00714C{sub hIgG} (μg/mL)–0.0147 with a correlation coefficient of 0.9968 over a range 0–150 μg/mL. Moreover, the light-addressable potentiometric sensor system also showed acceptable stability and reproducibility. All the results demonstrated that the system was more applicable to detection of disease biomarkers with simple operation, multiple-sample format and might hold great promise in various environmental, food, and clinical applications. - Highlights: • A novel structured light-addressable potentiometric sensor (LAPS) based on covalently functionalized membrane was designed. • The composition of the surface of LAPS chip was investigated by X-ray photoelectron spectroscopy (XPS). • hIgG dissolved in the supporting electrolyte solution can be detected by monitoring the potential shifts of LAPS.

  18. Creating a monthly time series of the potentiometric surface in the Upper Floridan aquifer, Northern Tampa Bay area, Florida, January 2000-December 2009

    Science.gov (United States)

    Lee, Terrie M.; Fouad, Geoffrey G.

    2014-01-01

    semivariograms decreased markedly between 2002 and 2003, timing that coincided with decreases in well-field pumping. Cross-validation results suggest that the kriging interpolation may smooth over the drawdown of the potentiometric surface near production wells. The groundwater monitoring network of 197 wells yielded an average kriging error in the potentiometric-surface elevations of 2 feet or less over approximately 70 percent of the map area. Additional data collection within the existing monitoring network of 260 wells and near selected well fields could reduce the error in individual months. Reducing the kriging error in other areas would require adding new monitoring wells. Potentiometric-surface elevations fluctuated by as much as 30 feet over the study period, and the spatially averaged elevation for the entire surface rose by about 2 feet over the decade. Monthly potentiometric-surface elevations describe the lateral groundwater flow patterns in the aquifer and are usable at a variety of spatial scales to describe vertical groundwater recharge and discharge conditions for overlying surface-water features.

  19. Mathematical modeling of flow-injection techniques and their applications for environmental monitoring

    International Nuclear Information System (INIS)

    Begum, N.N.; Ahmed, J.

    2006-01-01

    A classification of the existing mathematical models of flow-injection (FI) manifolds based on the main principles on which they are built, have been proposed. Numerous mathematical models of FI systems employing ideas from different scientific areas (e.g. mathematical statistics, chemical engineering, chromatography) have been developed so far. The models have been compared with respect to their predictive power, the complexity of their mathematical treatment, and the requirements for computation time when applied to single-line, multi-channel and conjugated two-line FI systems. It is concluded that the axially dispersed plug flow model deserves special attention because it offers an acceptable compromise between the conflicting requirements for maximal possible mathematical simplicity and maximal possible precision. Applicability of these existing flow-injection models to single-line, multi-channel and conjugated two-line systems for environmental monitoring have been discussed. (author)

  20. Transverse injection into Mach 2 flow behind a rearward-facing step - A 3-D, compressible flow test case for hypersonic combustor CFD validation

    Science.gov (United States)

    Mcdaniel, James C.; Fletcher, Douglas G.; Hartfield, Roy J.; Hollo, Steven D.

    1991-01-01

    A spatially-complete data set of the important primitive flow variables is presented for the complex, nonreacting, 3D unit combustor flow field employing transverse injection into a Mach 2 flow behind a rearward-facing step. A unique wind tunnel facility providing the capability for iodine seeding was built specifically for these measurements. Two optical techniques based on laser-induced-iodine fluorescence were developed and utilized for nonintrusive, in situ flow field measurements. LDA provided both mean and fluctuating velocity component measurements. A thermographic phosphor wall temperature measurement technique was developed and employed. Data from the 2D flow over a rearward-facing step and the complex 3D mixing flow with injection are reported.

  1. Improvement of Power Flow Calculation with Optimization Factor Based on Current Injection Method

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2014-01-01

    Full Text Available This paper presents an improvement in power flow calculation based on current injection method by introducing optimization factor. In the method proposed by this paper, the PQ buses are represented by current mismatches while the PV buses are represented by power mismatches. It is different from the representations in conventional current injection power flow equations. By using the combined power and current injection mismatches method, the number of the equations required can be decreased to only one for each PV bus. The optimization factor is used to improve the iteration process and to ensure the effectiveness of the improved method proposed when the system is ill-conditioned. To verify the effectiveness of the method, the IEEE test systems are tested by conventional current injection method and the improved method proposed separately. Then the results are compared. The comparisons show that the optimization factor improves the convergence character effectively, especially that when the system is at high loading level and R/X ratio, the iteration number is one or two times less than the conventional current injection method. When the overloading condition of the system is serious, the iteration number in this paper appears 4 times less than the conventional current injection method.

  2. Titulador potenciométrico automatizado baseado em sistema de fluxo monossegmentado Automated potentiometric titrator based in monosegmented flow system

    Directory of Open Access Journals (Sweden)

    Edgard Moreira Ganzarolli

    1999-02-01

    Full Text Available A new automated system for acid-base flow titrations is proposed. In the operation mode, several sample to titrant volumetric ratios are injected in an air segmented plug. Five three way solenoid valves and three acrilic junctions, assembled in a hidrodynamic injection system, were accountable for the monosegmented reagents plug formation. A turbulent flow reactor was used for a perfect mix of reagents in the plug. The detector system employed a glass combined electrode fitted in an acrilic holder. Titrations of hydrochloric, nitric and acetic acids, in several concentrations, were performed with standard sodium hidroxide, for evaluation of the efficiency of the system. The relative standard deviation of the determinations was about ±0,5% and each titration was carried out in 3-4 minutes. A Quick BASIC 4.5® program was developed for the titrator control.

  3. Recent Development in Optical Chemical Sensors Coupling with Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Fuensanta Sánchez Rojas

    2006-10-01

    Full Text Available Optical techniques for chemical analysis are well established and sensors based on thesetechniques are now attracting considerable attention because of their importance in applications suchas environmental monitoring, biomedical sensing, and industrial process control. On the other hand,flow injection analysis (FIA is advisable for the rapid analysis of microliter volume samples and canbe interfaced directly to the chemical process. The FIA has become a widespread automatic analyticalmethod for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, andease of assembling. In this paper, an overview of flow injection determinations by using opticalchemical sensors is provided, and instrumentation, sensor design, and applications are discussed. Thiswork summarizes the most relevant manuscripts from 1980 to date referred to analysis using opticalchemical sensors in FIA.

  4. Coupled Viscous Fluid Flow and Joint Deformation Analysis for Grout Injection in a Rock Joint

    Science.gov (United States)

    Kim, Hyung-Mok; Lee, Jong-Won; Yazdani, Mahmoud; Tohidi, Elham; Nejati, Hamid Reza; Park, Eui-Seob

    2018-02-01

    Fluid flow modeling is a major area of interest within the field of rock mechanics. The main objective of this study is to gain insight into the performance of grout injection inside jointed rock masses by numerical modeling of grout flow through a single rock joint. Grout flow has been widely simulated using non-Newtonian Bingham fluid characterized by two main parameters of dynamic viscosity and shear yield strength both of which are time dependent. The increasing value of these properties with injection time will apparently affect the parameters representing the grouting performance including grout penetration length and volumetric injection rate. In addition, through hydromechanical coupling a mutual influence between the injection pressure from the one side and the joint opening/closing behavior and the aperture profile variation on the other side is anticipated. This is capable of producing a considerable impact on grout spread within the rock joints. In this study based on the Bingham fluid model, a series of numerical analysis has been conducted using UDEC to simulate the flow of viscous grout in a single rock joint with smooth parallel surfaces. In these analyses, the time-dependent evolution of the grout fluid properties and the hydromechanical coupling have been considered to investigate their impact on grouting performance. In order to verify the validity of these simulations, the results of analyses including the grout penetration length and the injection flow rate were compared with a well-known analytical solution which is available for the simple case of constant grout properties and non-coupled hydraulic analysis. The comparison demonstrated that the grout penetration length can be overestimated when the time-dependent hardening of grout material is not considered. Moreover, due to the HM coupling, it was shown that the joint opening induced by injection pressure may have a considerable increasing impression on the values of penetration length and

  5. Simple home-made sensors for potentiometric titrations

    International Nuclear Information System (INIS)

    Selig, W.

    1982-04-01

    A sensor for potentiometric titrations was prepared by coating a spectroscopic graphite rod with a solution of poly(vinyl chloride) and dioctyphthalate in tetrahydrofuran. The reference electrode was an Ag/AgCl single-junction electrode. The sensor was used in precipitation, acid-base, compleximetric, and redox titrations. Preparation of the coated-graphite sensor is simple and rapid. Moreover, it is quite inexpensive. A limitation is its applicability in aqueous media only, because organic solvents will dissolve the membrane. Various uncoated types of graphite have also been investigated as sensors, particularly in two applications of interest in the analysis of propellants: the titration of nitroform and perchlorate. Obviously, these sensors can be used also in nonaqueous, or partially nonaqueous media. These sensors may also find use in the potentiometric titration of fluoride vs La(III) or Th

  6. The efficacy of IntraFlow intraosseous injection as a primary anesthesia technique.

    Science.gov (United States)

    Remmers, Todd; Glickman, Gerald; Spears, Robert; He, Jianing

    2008-03-01

    The purpose of this study was to compare the efficacy of intraosseous injection and inferior alveolar (IA) nerve block in anesthetizing mandibular posterior teeth with irreversible pulpitis. Thirty human subjects were randomly assigned to receive either intraosseous injection using the IntraFlow system (Pro-Dex Inc, Santa Ana, CA) or IA block as the primary anesthesia method. Pulpal anesthesia was evaluated via electric pulp testing at 4-minute intervals for 20 minutes. Two consecutive 80/80 readings were considered successful pulpal anesthesia. Anesthesia success or failure was recorded and groups compared. Intraosseous injection provided successful anesthesia in 13 of 15 subjects (87%). The IA block provided successful anesthesia in 9 of 15 subjects (60%). Although this difference was not statistically significant (p = 0.2148), the results of this preliminary study indicate that the IntraFlow system can be used as the primary anesthesia method in teeth with irreversible pulpitis to achieve predictable pulpal anesthesia.

  7. Jet flow analysis of liquid poison injection in a CANDU reactor using source term

    International Nuclear Information System (INIS)

    Chae, Kyung Myung; Choi, Hang Bok; Rhee, Bo Wook

    2001-01-01

    For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection velocity of the liquid poison is 27.8 m/s and the mass fraction of the poison is 8000 ppm (mg/kg). The simulation results have shown well-established jet flow field. In general, the jet develops narrowly at first but stretches rapidly. Then, the flow recirculates a little in r-x plane, while it recirculates largely in r-θ plane. As the time goes on, the adjacent jets contact each other and form a wavy front such that the whole jet develops in a plate form. his study has shown that the source term model can be effectively used for the analysis of the poison injection and the simulation result of the CANDU reactor is consistent with the model currently being used for the safety analysis. In the future, it is strongly recommended to analyze the transient (from helium tank to injection nozzle hole) of the poison injection by applying Bernoulli equation with real boundary conditions

  8. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  9. Development of an automated flow injection analysis system for determination of phosphate in nutrient solutions.

    Science.gov (United States)

    Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa

    2018-01-25

    A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2  = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  10. Fluorinated tripodal receptors for potentiometric chloride detection in biological fluids.

    Science.gov (United States)

    Pankratova, Nadezda; Cuartero, Maria; Jowett, Laura A; Howe, Ethan N W; Gale, Philip A; Bakker, Eric; Crespo, Gastón A

    2018-01-15

    Fluorinated tripodal compounds were recently reported to be efficient transmembrane transporters for a series of inorganic anions. In particular, this class of receptors has been shown to be suitable for the effective complexation of chloride, nitrate, bicarbonate and sulfate anions via hydrogen bonding. The potentiometric properties of urea and thiourea-based fluorinated tripodal receptors are explored here for the first time, in light of the need for reliable sensors for chloride monitoring in undiluted biological fluids. The ion selective electrode (ISE) membranes with tren-based tris-urea bis(CF 3 ) tripodal compound (ionophore I) were found to exhibit the best selectivity for chloride over major lipophilic anions such as salicylate ( [Formula: see text] ) and thiocyanate ( [Formula: see text] ). Ionophore I-based ISEs were successfully applied for chloride determination in undiluted human serum as well as artificial serum sample, the slope of the linear calibration at the relevant background of interfering ions being close to Nernstian (49.8±1.7mV). The results of potentiometric measurements were confirmed by argentometric titration. Moreover, the ionophore I-based ISE membrane was shown to exhibit a very good long-term stability of potentiometric performance over the period of 10 weeks. Nuclear magnetic resonance (NMR) titrations, potentiometric sandwich membrane experiments and density functional theory (DFT) computational studies were performed to determine the binding constants and suggest 1:1 complexation stoichiometry for the ionophore I with chloride as well as salicylate. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. O-(β-hydroxyethylrutosides determination by micellar flow injection (FI-spectrofluorimetry

    Directory of Open Access Journals (Sweden)

    Cecilia Mariana Peralta

    2014-12-01

    Full Text Available A simple, eco-friendly, sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethylrutosides. The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethylrutosides fluorescence enhancement, increasing considerably the sensitivity of detection. All the variables affecting the fluorescence intensity were studied and optimized. The flow rate was 5 mL/min with detection at 450 nm (after excitation at 346 nm. A linear correlation between drug amount and peak area was established for O-(β-hydroxyethylrutosides in the range of 0.01–200 µg/mL with a detection limit of 0.001 µg/mL (s/n=3. Validation processes were performed by recovering studies with satisfactory results. The new methodology can be employed for the routine analysis of O-(β-hydroxyethylrutosides in bulks as well as in commercial formulations. Keywords: O-(β-hydroxyethylrutosides, Micellar enhancement, Flow injection, Spectrofluorimetry, Pharmaceuticals

  12. An experimental study of the flow characteristics of fluidic device in a passive safety injection tank

    International Nuclear Information System (INIS)

    Cho, Seok; Song, Chul Hwa; Won, Suon Yeon; Min, Kyong Ho; Chung, Moon Ki

    1998-01-01

    It is considered to adopt passive safety injection tank (SIT) as a enhanced safety feature in KNGR. Passive SIT employs a vortex chamber as a fluidic device, which control injection flow rate passively by the variation of flow resistance produced by vortex intensity within the vortex chamber. To investigate the flow characteristics of the vortex chamber many tests have been carried out by using small-scale test facility. In this report the effects of geometric parameters of vortex chamber on discharge flow characteristics and the velocity measurement result of flow field, measured by PIV, are presented and discussed. (author). 25 refs., 11 tabs., 31 figs

  13. Potentiometric-surface map, 1993, Yucca Mountain and vicinity, Nevada

    International Nuclear Information System (INIS)

    Tucci, P.; Burkhardt, D.J.

    1995-01-01

    The revised potentiometric surface map here, using mainly 1993 average water levels, updates earlier maps of this area. Water levels are contoured with 20-m intervals, with additional 0.5-m contours in the small-gradient area SE of Yucca Mountain. Water levels range from 728 m above sea level SE of Yucca to 1,034 m above sea level north of Yucca. Potentiometric levels in the deeper parts of the volcanic rock aquifer range from 730 to 785 m above sea level. The potentiometric surface can be divided into 3 regions: A small gradient area E and SE of Yucca, a moderate-gradient area on the west side of Yucca, and a large-gradient area to the N-NE of Yucca. Water levels from wells at Yucca were examined for yearly trends (1986-93) using linear least-squares regression. Of the 22 wells, three had significant positive trends. The trend in well UE-25 WT-3 may be influenced by monitoring equipment problems. Tends in USW WT-7 and USW WTS-10 are similar; both are located near a fault west of Yucca; however another well near that fault exhibited no significant trend

  14. Potentiometric determination of iodides in urine

    International Nuclear Information System (INIS)

    Gikolaev, B.A.; Primakova, L.N.; Rakhman'ko, E.M.

    1996-01-01

    Variants of potentiometric method: determination using a calibrations plot, the Gran method, and the double addition method are considered. The method of double additions of the test solution to the reference one is suggested as the most favorable method of determining iodides in urine under clinical laboratory conditions. Refs. 5, tabs. 2

  15. Potentiometric Titrations for Measuring the Capacitance of Colloidal Photodoped ZnO Nanocrystals.

    Science.gov (United States)

    Brozek, Carl K; Hartstein, Kimberly H; Gamelin, Daniel R

    2016-08-24

    Colloidal semiconductor nanocrystals offer a unique opportunity to bridge molecular and bulk semiconductor redox phenomena. Here, potentiometric titration is demonstrated as a method for quantifying the Fermi levels and charging potentials of free-standing colloidal n-type ZnO nanocrystals possessing between 0 and 20 conduction-band electrons per nanocrystal, corresponding to carrier densities between 0 and 1.2 × 10(20) cm(-3). Potentiometric titration of colloidal semiconductor nanocrystals has not been described previously, and little precedent exists for analogous potentiometric titration of any soluble reductants involving so many electrons. Linear changes in Fermi level vs charge-carrier density are observed for each ensemble of nanocrystals, with slopes that depend on the nanocrystal size. Analysis indicates that the ensemble nanocrystal capacitance is governed by classical surface electrical double layers, showing no evidence of quantum contributions. Systematic shifts in the Fermi level are also observed with specific changes in the identity of the charge-compensating countercation. As a simple and contactless alternative to more common thin-film-based voltammetric techniques, potentiometric titration offers a powerful new approach for quantifying the redox properties of colloidal semiconductor nanocrystals.

  16. Home-Made Micro Valve for Determining Malachite Green Dye by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Amal Saadoon Majeed

    2017-07-01

    Full Text Available The research is included studying and designing micro flow injection system which is characterized with rapidity, simplicity, and low cost for the determination of green malachite dye. The study of flow rate of carrier stream, repeatability, dispersion coefficient, and calibration graph are conducted. It is found that the optimum conditions for the determination of mentioned dye are flow rate 4.200 mL/min, sampling rate 102 sample/h, limit of detection 0.05 ppm, linear range (0.05-18.00 ppm with linearity (R2=0.9700, RSD is 0.355, the repeatability for seven successive injections is studied for the two concentrations 5 ppm and 12 ppm, and the dispersion coefficient values are 1.73 and 1.28 at the two concentrations 2 ppm and 9 ppm respectively.

  17. New Potentiometric Wireless Chloride Sensors Provide High Resolution Information on Chemical Transport Processes in Streams

    Directory of Open Access Journals (Sweden)

    Keith Smettem

    2017-07-01

    Full Text Available Quantifying the travel times, pathways, and dispersion of solutes moving through stream environments is critical for understanding the biogeochemical cycling processes that control ecosystem functioning. Validation of stream solute transport and exchange process models requires data obtained from in-stream measurement of chemical concentration changes through time. This can be expensive and time consuming, leading to a need for cheap distributed sensor arrays that respond instantly and record chemical transport at points of interest on timescales of seconds. To meet this need we apply new, low-cost (in the order of a euro per sensor potentiometric chloride sensors used in a distributed array to obtain data with high spatial and temporal resolution. The application here is to monitoring in-stream hydrodynamic transport and dispersive mixing of an injected chemical, in this case NaCl. We present data obtained from the distributed sensor array under baseflow conditions for stream reaches in Luxembourg and Western Australia. The reaches were selected to provide a range of increasingly complex in-channel flow patterns. Mid-channel sensor results are comparable to data obtained from more expensive electrical conductivity meters, but simultaneous acquisition of tracer data at several positions across the channel allows far greater spatial resolution of hydrodynamic mixing processes and identification of chemical ‘dead zones’ in the study reaches.

  18. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    Directory of Open Access Journals (Sweden)

    Jaroon Jakmunee

    2008-06-01

    Full Text Available A stopped-flow injection (FI spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product zone. When the flow started again, a concentrated product zone was pushed into a flow cell and a signal profile due to light absorption of the product was recorded. Employing a lab-built semi-automatic stopped-FI analyser, the analysis can be performed with higher degree of automation and low chemical consumption. Linear calibration graph in the range of 5-50 mg ClO3- L-1 was obtained, with detection limit of 1.4 mg ClO3- L-1. Relative standard deviation of 2.2% (30 mg ClO3- L-1, n=10 and sample throughput of about 20 h-1 were achieved. The system was applied to soil samples and validated by batch spectrophotometric and standard titrimetric methods.

  19. Continuous-Flow Production of Injectable Liposomes via a Microfluidic Approach

    Science.gov (United States)

    Zizzari, Alessandra; Bianco, Monica; Perrone, Elisabetta; Amato, Francesco; Maruccio, Giuseppe; Rendina, Filippo; Arima, Valentina

    2017-01-01

    Injectable liposomes are characterized by a suitable size and unique lipid mixtures, which require time-consuming and nonstraightforward production processes. The complexity of the manufacturing methods may affect liposome solubility, the phase transition temperatures of the membranes, the average particle size, and the associated particle size distribution, with a possible impact on the drug encapsulation and release. By leveraging the precise steady-state control over the mixing of miscible liquids and a highly efficient heat transfer, microfluidic technology has proved to be an effective and direct methodology to produce liposomes. This approach results particularly efficient in reducing the number of the sizing steps, when compared to standard industrial methods. Here, Microfluidic Hydrodynamic Focusing chips were produced and used to form liposomes upon tuning experimental parameters such as lipids concentration and Flow-Rate-Ratios (FRRs). Although modelling evidenced the dependence of the laminar flow on the geometric constraints and the FRR conditions, for the specific formulation investigated in this study, the lipids concentration was identified as the primary factor influencing the size of the liposomes and their polydispersity index. This was attributed to a predominance of the bending elasticity modulus over the vesiculation index in the lipid mixture used. Eventually, liposomes of injectable size were produced using microfluidic one-pot synthesis in continuous flow. PMID:29232873

  20. Stability Analysis of High-Speed Boundary-Layer Flow with Gas Injection

    Science.gov (United States)

    2014-06-01

    laminar-turbulent transition on slender bodies in a hypersonic flow at small angles of attack is caused by amplification of acoustic waves trapped in...x decreases and slowly approaches the no-blow distribution. These CFD data demonstrate that the injection strongly affects the near-wall flow...conclusion. Figure 10 shows that the spatial growth rates ( )  are maximal for mode 0 corresponding to the Mack second mode – typical for hypersonic

  1. Potentiometric application of boron- and phosphorus-doped glassy carbon electrodes

    Directory of Open Access Journals (Sweden)

    ZORAN V. LAUSEVIC

    2001-03-01

    Full Text Available Acomparative study was carried out of the potentiometric application of boronand phosphorus-doped and undoped glassy carbon samples prepared at the same heat treatment temperature (HTT 1000°C. The electrochemical activities of the obtained electrode materials were investigated on the example of argentometric titrations. It was found that the electrochemical behaviour of the doped glassy carbon samples are very similar to a Sigri (undoped glassy carbon sample (HTT 2400°C. The experiments showed that the potentiometric response depends on the polarization mode, the nature of the sample, the pretreatment of the electrode surface, and the nature of the supporting electrolyte. The amounts of iodide, bromide, and of chloridewere determined to be 1.27 mg, 0.80 mg and 0.54 mg, respectively, with a maximum relative standard deviation of less than 1.1%. The obtained results are in good agreement with the results of comparative potentiometric titrations using a silver indicator electrode. The titrationmethod was applied to the indirect determination of pyridoxine hydrochloride, i.e., vitamin B6.

  2. Theoretical considerations of Flow Injection Analysis in the Absence of Chemical Reactions

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2000-01-01

    The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters are associa...... that any deviation from the features of the present model and the results of a tentative chemical reaction with one of the test compounds, is related to chemical kinetics.......The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters...

  3. Potentiometric determination of uranium with cobalt (3) acetate as oxidimetric titrant

    International Nuclear Information System (INIS)

    Muhammad, H.; Ishrat, P.; Zyka, J.

    1972-01-01

    A potentiometric method for the determination of uranium through the reduction of hexavalent to tetravalent state and its potentiometric oxidation in 8 N sulphuric acid with standard cobalt (3)-acetate has been worked out. The method is quite accurate with the error not exceeding 1% for mg amounts. Moreover an apparatus for preservation of reduced solution of uranium and its delivery for titrations has been designed. The same apparatus can be used for reducing and preserving solutions of strong reducing titrants. (author)

  4. Determination of albumin in bronchoalveolar lavage fluid by flow-injection fluorometry using chromazurol S.

    Science.gov (United States)

    Sato, Takaji; Saito, Yoshihiro; Chikuma, Masahiko; Saito, Yutaka; Nagai, Sonoko

    2008-03-01

    A highly sensitive flow injection fluorometry for the determination of albumin was developed and applied to the determination of albumin in human bronchoalveolar lavage fluids (BALF). This method is based on binding of chromazurol S (CAS) to albumin. The calibration curve was linear in the range of 5-200 microg/ml of albumin. A highly linear correlation (r=0.986) was observed between the albumin level in BALF samples (n=25) determined by the proposed method and by a conventional fluorometric method using CAS (CAS manual method). The IgG interference was lower in the CAS flow injection method than in the CAS manual method. The albumin level in BALF collected from healthy volunteers (n=10) was 58.5+/-13.1 microg/ml. The albumin levels in BALF samples obtained from patients with sarcoidosis and idiopathic pulmonary fibrosis were increased. This finding shows that the determination of albumin levels in BALF samples is useful for investigating lung diseases and that CAS flow injection method is promising in the determination of trace albumin in BALF samples, because it is sensitive and precise.

  5. Comparison of methods for accurate end-point detection of potentiometric titrations

    Science.gov (United States)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  6. Comparison of methods for accurate end-point detection of potentiometric titrations

    International Nuclear Information System (INIS)

    Villela, R L A; Borges, P P; Vyskočil, L

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper

  7. Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: application to sulfamethoxazole and trimethoprim.

    Science.gov (United States)

    Almeida, S A A; Arasa, E; Puyol, M; Martinez-Cisneros, C S; Alonso-Chamarro, J; Montenegro, M C B S M; Sales, M G F

    2011-12-15

    Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol-gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about -58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes -54.7 (SMX) and +57.8 (TMP) m

  8. Non-darcy flow behavior mean high-flux injection wells in porous and fractured formations

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yu-Shu

    2003-04-25

    This paper presents a study of non-Darcy fluid flow through porous and fractured rock, which may occur near wells during high-flux injection of waste fluids into underground formations. Both numerical and analytical models are used in this study. General non-Darcy flow is described using the Forchheimer equation, implemented in a three-dimensional, multiphase flow reservoir simulator. The non-Darcy flow through a fractured reservoir is handled using a general dual continuum approach, covering commonly used conceptual models, such as double porosity, dual permeability, explicit fracture, etc. Under single-phase flow conditions, an approximate analytical solution, as an extension of the Warren-Root solution, is discussed. The objectives of this study are (1) to obtain insights into the effect of non-Darcy flow on transient pressure behavior through porous and fractured reservoirs and (2) to provide type curves for well test analyses of non-Darcy flow wells. The type curves generated include various types of drawdown, injection, and buildup tests with non-Darcy flow occurring in porous and fractured reservoirs. In addition, non-Darcy flow into partially penetrating wells is also considered. The transient-pressure type curves for flow in fractured reservoirs are based on the double-porosity model. Type curves provided in this work for non-Darcy flow in porous and fractured reservoirs will find their applications in well test interpretation using a type-curve matching technique.

  9. Continuous-Flow Production of Injectable Liposomes via a Microfluidic Approach

    Directory of Open Access Journals (Sweden)

    Alessandra Zizzari

    2017-12-01

    Full Text Available Injectable liposomes are characterized by a suitable size and unique lipid mixtures, which require time-consuming and nonstraightforward production processes. The complexity of the manufacturing methods may affect liposome solubility, the phase transition temperatures of the membranes, the average particle size, and the associated particle size distribution, with a possible impact on the drug encapsulation and release. By leveraging the precise steady-state control over the mixing of miscible liquids and a highly efficient heat transfer, microfluidic technology has proved to be an effective and direct methodology to produce liposomes. This approach results particularly efficient in reducing the number of the sizing steps, when compared to standard industrial methods. Here, Microfluidic Hydrodynamic Focusing chips were produced and used to form liposomes upon tuning experimental parameters such as lipids concentration and Flow-Rate-Ratios (FRRs. Although modelling evidenced the dependence of the laminar flow on the geometric constraints and the FRR conditions, for the specific formulation investigated in this study, the lipids concentration was identified as the primary factor influencing the size of the liposomes and their polydispersity index. This was attributed to a predominance of the bending elasticity modulus over the vesiculation index in the lipid mixture used. Eventually, liposomes of injectable size were produced using microfluidic one-pot synthesis in continuous flow.

  10. Potentiometric Titration Method for Quantitative Determination of Hydrogen Peroxide

    National Research Council Canada - National Science Library

    Bessette, Russell R

    2005-01-01

    An electrochemical potentiometric titration method that entails titration of a known volume of a catholyte containing an unknown amount of hydrogen peroxide in a titration cell having two electrodes...

  11. Entropy Generation in a Rotating Couette Flow with Suction/Injection

    Directory of Open Access Journals (Sweden)

    S. Das

    2015-05-01

    Full Text Available The present paper is concerned with an analytical study of entropy generation in viscous incompressible Couette flow with suction/injection in a rotating frame of reference. One of the plate is held at rest and the other one moves with an uniform velocity.The flow induced by the moving plate. An exact solution of governing equations has been obtained in closed form. The entropy generation number and the Bejan number are also obtained. The influences of each of the governing parameters on velocity, temperature, entropy generation and Bejan number are discussed with the help of graphs.

  12. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    Science.gov (United States)

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  13. Flow injection analysis: Emerging tool for laboratory automation in radiochemistry

    International Nuclear Information System (INIS)

    Egorov, O.; Ruzicka, J.; Grate, J.W.; Janata, J.

    1996-01-01

    Automation of routine and serial assays is a common practice of modern analytical laboratory, while it is virtually nonexistent in the field of radiochemistry. Flow injection analysis (FIA) is a general solution handling methodology that has been extensively used for automation of routine assays in many areas of analytical chemistry. Reproducible automated solution handling and on-line separation capabilities are among several distinctive features that make FI a very promising, yet under utilized tool for automation in analytical radiochemistry. The potential of the technique is demonstrated through the development of an automated 90 Sr analyzer and its application in the analysis of tank waste samples from the Hanford site. Sequential injection (SI), the latest generation of FIA, is used to rapidly separate 90 Sr from interfering radionuclides and deliver separated Sr zone to a flow-through liquid scintillation detector. The separation is performed on a mini column containing Sr-specific sorbent extraction material, which selectively retains Sr under acidic conditions. The 90 Sr is eluted with water, mixed with scintillation cocktail, and sent through the flow cell of a flow through counter, where 90 Sr radioactivity is detected as a transient signal. Both peak area and peak height can be used for quantification of sample radioactivity. Alternatively, stopped flow detection can be performed to improve detection precision for low activity samples. The authors current research activities are focused on expansion of radiochemical applications of FIA methodology, with an ultimate goal of creating a set of automated methods that will cover the basic needs of radiochemical analysis at the Hanford site. The results of preliminary experiments indicate that FIA is a highly suitable technique for the automation of chemically more challenging separations, such as separation of actinide elements

  14. Determination of vanadium(V) by direct automatic potentiometric titration with EDTA using a chemically modified electrode as a potentiometric sensor.

    Science.gov (United States)

    Quintar, S E; Santagata, J P; Cortinez, V A

    2005-10-15

    A chemically modified electrode (CME) was prepared and studied as a potentiometric sensor for the end-point detection in the automatic titration of vanadium(V) with EDTA. The CME was constructed with a paste prepared by mixing spectral-grade graphite powder, Nujol oil and N-2-naphthoyl-N-p-tolylhydroxamic acid (NTHA). Buffer systems, pH effects and the concentration range were studied. Interference ions were separated by applying a liquid-liquid extraction procedure. The CME did not require any special conditioning before using. The electrode was constructed with very inexpensive materials and was easily made. It could be continuously used, at least two months without removing the paste. Automatic potentiometric titration curves were obtained for V(V) within 5 x 10(-5) to 2 x 10(-3)M with acceptable accuracy and precision. The developed method was applied to V(V) determination in alloys for hip prosthesis.

  15. Revised potentiometric-surface map, Yucca Mountain and vicinity, Nevada

    International Nuclear Information System (INIS)

    Ervin, E.M.; Luckey, R.R.; Burkhardt, D.J.

    1994-01-01

    The revised potentiometric-surface map presented in this report updates earlier maps of the Yucca Mountain area using mainly 1988 average water levels. Because of refinements in the corrections to the water-level measurements, these water levels have increased accuracy and precision over older values. The small-gradient area to the southeast of Yucca Mountain is contoured with a 0.25-meter interval and ranges in water-level altitude from 728.5 to 73 1.0 meters. Other areas with different water levels, to the north and west of Yucca Mountain, are illustrated with shaded patterns. The potentiometric surface can be divided into three regions: (1) A small-gradient area to the southeast of Yucca Mountain, which may be explained by flow through high-transmissivity rocks or low ground-water flux through the area; (2) A moderate-gradient area, on the western side of Yucca Mountain, where the water-level altitude ranges from 775 to 780 meters, and appears to be impeded by the Solitario Canyon Fault and a splay of that fault; and (3) A large-gradient area, to the north-northeast of Yucca Mountain, where water level altitude ranges from 738 to 1,035 meters, possibly as a result of a semi-perched groundwater system. Water levels from wells at Yucca Mountain were examined for yearly trends using linear least-squares regression. Data from five wells exhibited trends which were statistically significant, but some of those may be a result of slow equilibration of the water level from drilling in less permeable rocks. Adjustments for temperature and density changes in the deep wells with long fluid columns were attempted, but some of the adjusted data did not fit the surrounding data and, thus, were not used

  16. Potentiometric studies on quaternary complexes of dioxouranium(VI)

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Vinod; Chaturvedi, G K [Agra Coll., (India). Chemical Laboratories

    1979-10-01

    The formation of quaternary complexes of dioxouranium(VI) with three different organic acids (OX, MALN and SA, SSA, TAR or TMA) has been inferred from the potentiometric studies. The formation constants for the resulting triligand complexes have been evaluated.

  17. Exploiting flow injection and sequential injection for trace metal determinations in conjunction with detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    and selectivity. Either in order to separate/preconcentrate the analyte material, or because of the presence of potentially interfering matrix constituents. Such pretreatments are advantageously performed in flow injection (FI) or sequential injection (SI) manifolds, where all appropriate unit operations can...

  18. Potentiometric titration of zinc and cadmium in electrolytes of in galvanic baths

    International Nuclear Information System (INIS)

    Kosyuga, E.A.; Kalugin, A.A.; Gur'ev, I.A.

    1979-01-01

    The method of potentiometric titration of zinc and cadmium by complexone 3 in electrolytes of galvanic baths using sulphide - silver electrode for determining the finite point of titration is suggested. Copper (2) ions are proposed as indicator ions. The potentiometric determination should be performed at pH=10. The method is verified on model electrolyte solutions and on the electrolyte solutions of operating baths.The technique can be used for automatic control. The time for analysis is 10 minutes

  19. Potentiometric determination of ibuprofen, indomethacin and naproxen using an artificial neural network calibration

    Directory of Open Access Journals (Sweden)

    A. HAKAN AKTAŞ

    2008-01-01

    Full Text Available In this study, three anti-inflammatory agents, namely ibuprofen, indomethacin and naproxen, were titrated potentiometrically using tetrabutylammonium hydroxide in acetonitrile solvent under a nitrogen atmosphere at 25 °C. MATLAB 7.0 software was applied for data treatment as a multivariate calibration tool in the potentiometric titration procedure. An artificial neural network (ANN was used as a multivariate calibration tool in the potentiometric titration to model the complex non-linear relationship between ibuprofen, indomethacin and naproxen concentrations and the millivolt (mV of the solutions measured after the addition of different volumes of the titrant. The optimized network predicted the concentrations of agents in synthetic mixtures. The results showed that the employed ANN can precede the titration data with an average relative error of prediction of less than 2.30 %.

  20. Optimization of a flow injection analysis system for multiple solvent extraction

    International Nuclear Information System (INIS)

    Rossi, T.M.; Shelly, D.C.; Warner, I.M.

    1982-01-01

    The performance of a multistage flow injection analysis solvent extraction system has been optimized. The effect of solvent segmentation devices, extraction coils, and phase separators on performance characteristics is discussed. Theoretical consideration is given to the effects and determination of dispersion and the extraction dynamics within both glass and Teflon extraction coils. The optimized system has a sample recovery similar to an identical manual procedure and a 1.5% relative standard deviation between injections. Sample throughput time is under 5 min. These characteristics represent significant improvements over the performance of the same system before optimization. 6 figures, 2 tables

  1. Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline.

    Science.gov (United States)

    Lakard, Boris; Magnin, Delphine; Deschaume, Olivier; Vanlancker, Guilhem; Glinel, Karine; Demoustier-Champagne, Sophie; Nysten, Bernard; Jonas, Alain M; Bertrand, Patrick; Yunus, Sami

    2011-06-15

    A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANI), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L(-1) urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Leal, L.O.; Elsholz, O.; Forteza, R.; Cerda, V.

    2006-01-01

    A new software-controlled time-based multisyringe flow injection system for mercury determination by cold-vapor atomic absorption spectrometry is proposed. Precise known volumes of sample, reducing agent (1.1% SnCl 2 in 3% HCl) and carrier (3% HCl) are dispensed into a gas-liquid separation cell with a multisyringe burette coupled with one three-way solenoid valve. An argon flow delivers the reduced mercury to the spectrometer. The optimization of the system was carried out testing reaction coils and gas-liquid separators of different design as well as changing parameters, such as sample and reagents volumes, reagent concentrations and carrier gas flow rate, among others. The analytical curves were obtained within the range 50-5000 ng L -1 . The detection limit (3σ b /S) achieved is 5 ng L -1 . The relative standard deviation (R.S.D.) was 1.4%, evaluated from 16 successive injections of 250 ng L -1 Hg standard solution. The injection and sample throughput per hour were 44 and 11, respectively. This technique was validated by means of solid and water reference materials with good agreement with the certified values and was successfully applied to fish samples

  3. Improving the limits of detection in potentiometric sensors

    NARCIS (Netherlands)

    Bent, Van Der J.F.; Puik, E.C.N.; Tong, H.D.; Rijn, Van C.J.M.

    2015-01-01

    Potentiometric sensors will generally suffer from unwanted responses as a result to changing temperatures by generating an electromotive force. Typically, this voltage drift has a non-linear character and therefore it is difficult to compensate using linear algorithms implemented in the analogue

  4. Bubble-size distributions produced by wall injection of air into flowing freshwater, saltwater and surfactant solutions

    Science.gov (United States)

    Winkel, Eric S.; Ceccio, Steven L.; Dowling, David R.; Perlin, Marc

    2004-12-01

    As air is injected into a flowing liquid, the resultant bubble characteristics depend on the properties of the injector, near-wall flow, and flowing liquid. Previous research has shown that near-wall bubbles can significantly reduce skin-friction drag. Air was injected into the turbulent boundary layer on a test section wall of a water tunnel containing various concentrations of salt and surfactant (Triton-X-100, Union Carbide). Photographic records show that the mean bubble diameter decreased monotonically with increasing salt and surfactant concentrations. Here, 33 ppt saltwater bubbles had one quarter, and 20 ppm Triton-X-100 bubbles had one half of the mean diameter of freshwater bubbles.

  5. Irreversibility analysis of magneto-hydrodynamic nanofluid flow injected through a rotary disk

    Directory of Open Access Journals (Sweden)

    Rashidi Mohammad Mehdi

    2015-01-01

    Full Text Available The non-linear Navier-Stokes equations governed on the nanofluid flow injected through a rotary porous disk in the presence of an external uniform vertical magnetic field can be changed to a system of non-linear partial differential equations by applying similar parameter. In this study, partial differential equations are analytically solved by the modified differential transform method, Pade differential transformation method to obtain self-similar functions of motion and temperature. A very good agreement is observed between the obtained results of Pade differential transformation method and those of previously published ones. Then it has become possible to do a comprehensive parametric analysis on the entropy generation in this case to demonstrate the effects of physical flow parameters such as magnetic interaction parameter, injection parameter, nanoparticle volume fraction, dimensionless temperature difference, rotational Brinkman number and the type of nanofluid on the problem.

  6. Spectrofluorimetric determination of cerium by flow injection analysis

    International Nuclear Information System (INIS)

    Liu Shaorong; Meng Jian; Liu Wenhua

    1990-01-01

    A spectrofluorimetric method for the determination of cerium (λ ex/em:251/365 nm) in hydrochloric acid solution by flow injection analysis is presented. It has well developed the normal spectrofluorimetric method for determination of cerium and has made: 1, the determination procedure shortened; 2, the determination speed increased to about 180 samples per hour; 3, the determination range widened to 0.05-100.0 ppm CeO 2 , abouot two times as wide as the normal spectrofluorimetric method; and 4, the relative standard deviation lessened (about 0.47% for 0.1 ppm CeO 2 , n = 13)

  7. On-line dynamic fractionation and automatic determination of inorganic phosphorous in environmental solid substrates exploiting sequential injection microcolumn extraction and flow injection analysi

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the pa......Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified...... by the partitioning of inorganic phosphorous in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump. Three different soil phase...... associations for phosphorus, that is, exchangeable, Al- and Fe-bound and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the 3 steps of the Hietjles-Litjkema (HL) scheme involving the use of 1.0 M NH4Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents...

  8. Label-free and substrate-free potentiometric aptasensing using polycation-sensitive membrane electrodes.

    Science.gov (United States)

    Ding, Jiawang; Chen, Yan; Wang, Xuewei; Qin, Wei

    2012-02-21

    A potentiometric label-free and substrate-free (LFSF) aptasensing strategy which eliminates the labeling, separation, and immobilization steps is described in this paper. An aptamer binds specifically to a target molecule via reaction incubation, which could induce a change in the aptamer conformation from a random coil-like configuration to a rigid folded structure. Such a target binding-induced aptamer conformational change effectively prevents the aptamer from electrostatically interacting with the protamine binding domain. This could either shift the response curve for the potentiometric titration of the aptamer with protamine as monitored by a conventional polycation-sensitive membrane electrode or change the current-dependent potential detected by a protamine-conditioned polycation-sensitive electrode with the pulsed current-driven ion fluxes of protamine across the polymeric membrane. Using adenosine triphosphate (ATP) as a model analyte, the proposed concept offers potentiometric detection of ATP down to the submicromolar concentration range and has been applied to the determination of ATP in HeLa cells. In contrast to the current LFSF aptasensors based on optical detection, the proposed strategy allows the LFSF biosensing of aptamer/target binding events in a homogeneous solution via electrochemical transduction. It is anticipated that the proposed strategy will lay a foundation for development of potentiometric sensors for LFSF aptasensing of a variety of analytes where target binding-induced conformational changes such as the formation of folded structures and the opening of DNA hairpin loops are involved.

  9. Potentiometric-level monitoring program, Mississippi and Louisiana: Annual status report for fiscal year 1985

    International Nuclear Information System (INIS)

    1986-10-01

    Potentiometric-level data presented in this report were collected at 82 wells in Mississippi and Louisiana from October 1984 through September 1985. These wells are located near Richton and Cypress Creek Domes in Mississippi and Vacherie dome in Louisiana. Three wells were reinstated to the program during this period. Two previously destroyed wells were deleted from the program. Protective barriers were installed around 26 shallow borings in Mississippi. Cursory analysis of the data in Mississippi indicated minimal, if any, change in potentiometric level during the past year in the Citronelle, Hattiesburg, Cockfield, Sparta, and Wilcox Formations. A slight decline, on the order of 0.3 meter (1 foot), occurred during the past year in well MCCG-1, which is screened in the caprock of Cypress Creek Dome. The potentiometric level in well MRIG-9, in the caprock of Richton Dome, stabilized during fiscal year 1985 following 5 years of increase. The Catahoula Formation experienced a continuing decline of about 0.3 meter/year (1 foot/year). Well MH-5C, screened in the Cook Mountain Formation, showed a continuing, long-term, upward trend on the order of 1.5 meters (4.9 feet) during the past year. The potentiometric level of well MH-8C, screened in the Cook Mountain Formation, stabilized during fiscal year 1985, following 5 years of large annual increases. Wells screened in the Austin Formation in Louisiana showed a downward trend of 0.3 to 1 meter (1 to 3.3 feet) during fiscal year 1985. Other formations in Louisiana generally showed no change in potentiometric level

  10. Principles and Applications of Flow Injection Analysis in Biosensors

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    In practical applications biosensors are often forced to operate under less than optimal conditions. Because of their construction, and the physical processes and chemical reactions involved in their operation, compromise conditions are frequently required to synchronize all events taking place....... Therefore, and in order to implement functions such as periodic calibration, conditioning and possible regeneration of the biosensor, and, very importantly, to yield the freedom to select the optimum detection means, it is advantageous to use these devices in a flow-through mode, particularly by employing...... the flow injection (FI) approach. The capacity of FI, as offering itself as a complementary facility to augment the performance of biosensors, and in many cases as an attractive alternative, is demonstrated by reference to selected examples, comprising assays based on enzymatic procedures with optical...

  11. MHD flow over a permeable stretching/shrinking sheet of a nanofluid with suction/injection

    Directory of Open Access Journals (Sweden)

    Sandeep Naramgari

    2016-06-01

    Full Text Available In this study we analyzed the influence of thermal radiation and chemical reaction on two dimensional steady magnetohydrodynamic flow of a nanofluid past a permeable stretching/shrinking sheet in the presence of suction/injection. We considered nanofluid volume fraction on the boundary is submissive controlled, which makes the present study entirely different from earlier studies and physically more realistic. The equations governing the flow are solved numerically. Effects of non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented through graphs. Also, coefficient of skin friction and local Nusselt number is investigated for stretching/shrinking and suction/injection cases separately and presented through tables. Comparisons with existed results are presented. Present results have an excellent agreement with the existed studies under some special assumptions. Results indicate that the enhancement in Brownian motion and thermophoresis parameters depreciates the nanoparticle concentration and increases the mass transfer rate. Dual solutions exist only for certain range of stretching/shrinking and suction/injection parameters.

  12. Spectrophotometric flow injection catalytic determination of molybdenum in plant digest using ion exchange resin

    International Nuclear Information System (INIS)

    Pessenda, L.C.R.

    1987-03-01

    A spectrophotometric flow injection analytical method based on the catalytic action of molybdenum on the oxidation of iodide by hydrogen peroxide in acidic medium is proposed for the molybdenum determination in plant digests. A cation exchange resin column is incorporated into a flow injection system for removal of interferents. The following system variables were investigated and optimized: reagent concentrations, sample injection volume, mixing and reaction coil lengths, temperature, sampling time, pumping rate and concentration of eluting agents. The effects of interfering species and of the acidity of samples on the molybdenum retention by the ion exchange resin column were investigated. The proposed method is characterized by good precision (r.s.d. (2.0%), a sampling rate of about 40 samples per hour, and permits the determination of molybdenum in plant digests in the range 1.0 to 40.0 μg/l. The results compare well with those obtained by graphite furnace atomic absorption spectrometry. (author) [pt

  13. Potentiometric titration and equivalent weight of humic acid

    Science.gov (United States)

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  14. Considering the potential effect of faulting on regional-scale groundwater flow: an illustrative example from Australia's Great Artesian Basin

    Science.gov (United States)

    Smerdon, Brian D.; Turnadge, Chris

    2015-08-01

    Hydraulic head measurements in the Great Artesian Basin (GAB), Australia, began in the early 20th century, and despite subsequent decades of data collection, a well-accepted smoothed potentiometric surface has continually assumed a contiguous aquifer system. Numerical modeling was used to produce alternative potentiometric surfaces for the Cadna-owie-Hooray aquifers with and without the effect of major faults. Where a fault created a vertical offset between the aquifers and was juxtaposed with an aquitard, it was assumed to act as a lateral barrier to flow. Results demonstrate notable differences in the central portion of the study area between potentiometric surfaces including faults and those without faults. Explicitly considering faults results in a 25-50 m difference where faults are perpendicular to the regional flow path, compared to disregarding faults. These potential barriers create semi-isolated compartments where lateral groundwater flow may be diminished or absent. Groundwater management in the GAB relies on maintaining certain hydraulic head conditions and, hence, a potentiometric surface. The presence of faulting has two implications for management: (1) a change in the inferred hydraulic heads (and associated fluxes) at the boundaries of regulatory jurisdictions; and (2) assessment of large-scale extractions occurring at different locations within the GAB.

  15. Flow visualization and simulation of the filling process during injection molding

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2017-01-01

    To directly compare experimental moldings from an injection molding machine with simulations, a special mold has been produced with a glass window. The injection plane is perpendicular to the opening and closing planes, in order for the 55. mm thick glass window to be easily visible from the side....... These two had significant effects on the filling times and injection pressure calculated by the simulations. Other effects investigated included transient thermal management of the mold, pressure dependent viscosity and wall slip, but their effect were not remarkably large in this work. The obtained....... A high speed camera recording 500 frames per second was employed, and the mold had three thermocouples and two pressure sensors installed. The molded part is a 2. mm thick plate with a 0.5. mm thin section, which creates a characteristic V-shaped flow pattern. Two different materials were employed...

  16. Dual-phase gas-permeation flow-injection thermometric analysis for the determination of carbon dioxide.

    Science.gov (United States)

    Liu, S J; Tubino, M

    1998-11-01

    A flow-injection configuration based on a dual-phase gas-permeation system from a liquid donor to a gas acceptor stream with a thermistor flow-through detector is proposed for the direct analysis of the gas in the acceptor. This system was applied for the determination of carbon dioxide (in the form of carbonate) using the following chemical reaction: CO(2)(g)+2NH(3)(g)+H(2)O(g)=(NH(4))(2)CO(3)(s), with a linear response from 1x10(-3) to 50x10(-3) mol l(-1) of CO(3)(2-). Carbon dioxide was produced in the liquid donor and permeated into the gaseous acceptor stream of air/water vapor. The detection limit is 1x10(-3) mol l(-1) of carbonate, and a sampling frequency of 60 h(-1) is achieved with a relative standard deviation of 4.1% for replicate injections. The dual-phase gas-permeation flow-injection manifold, along with the membrane and phase separations, as well as the chemical reaction, provides enhanced selectivity when compared with the system employing a liquid acceptor stream, as serious interferents in this system, for instance, acetate and formate, among others, do not interfere in the proposed system.

  17. Three-dimensional simulation of flow and combustion for pulverised coal injection

    Energy Technology Data Exchange (ETDEWEB)

    Guo, B.Y.; Zulli, P.; Rogers, H.; Mathieson, J.G.; Yu, A.B. [BlueScope Steel Research, Port Kembla, NSW (Australia)

    2005-07-01

    A three-dimensional numerical model of pulverised coal injection has been developed for simulating coal flow and combustion in the tuyere and raceway of a blast furnace. The model has been used to simulate previously reported combustion tests, which feature an inclined co-axial lance with an annular cooling gas. The predicted coal burnout agrees well with that measured for three coals with volatile contents and particle size ranging between 20.2-36.4% and particle sizes 1-200 {mu}m. Many important phenomena including flow asymmetry, recirculating flow and particle dispersion in the combustion chamber have been predicted. The current model can reproduce the experimental observations including the effects on burnout of coal flowrate and the introduction of methane for lance cooling.

  18. Optimized and validated flow-injection spectrophotometric analysis of topiramate, piracetam and levetiracetam in pharmaceutical formulations.

    Science.gov (United States)

    Hadad, Ghada M; Abdel-Salam, Randa A; Emara, Samy

    2011-12-01

    Application of a sensitive and rapid flow injection analysis (FIA) method for determination of topiramate, piracetam, and levetiracetam in pharmaceutical formulations has been investigated. The method is based on the reaction with ortho-phtalaldehyde and 2-mercaptoethanol in a basic buffer and measurement of absorbance at 295 nm under flow conditions. Variables affecting the determination such as sample injection volume, pH, ionic strength, reagent concentrations, flow rate of reagent and other FIA parameters were optimized to produce the most sensitive and reproducible results using a quarter-fraction factorial design, for five factors at two levels. Also, the method has been optimized and fully validated in terms of linearity and range, limit of detection and quantitation, precision, selectivity and accuracy. The method was successfully applied to the analysis of pharmaceutical preparations.

  19. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry.

    Science.gov (United States)

    Shamsipur, Mojtaba; Dezaki, Abbas Shirmardi; Akhond, Morteza; Sharghi, Hashem; Paziraee, Zahra; Alizadeh, Kamal

    2009-12-30

    A new sulfur-containing macrocyclic diamide, 1,15-diaza-3,4,12,13-dibenzo-5,11-dithia-8-oxa-1,15-(2,6-pyrido)cyclooctadecan-2,14-dione, L, was synthesized, characterized and used as an active component for fabrication of PVC-based polymeric membrane (PME), coated graphite (CGE) and coated silver wire electrodes (CWE) for sensing Cd(2+) ion. The electrodes exhibited linear Nernstian responses to Cd(2+) ion in the concentration range of 3.3 x 10(-6) to 3.3 x 10(-1)M (for PME, LOD=1.2 x 10(-6)M), 2.0 x 10(-7) to 3.3 x 10(-1)M (for CWE, LOD=1.3 x 10(-7)M) and 1.6 x 10(-8) to 1.3 x 10(-1)M (for CGE, LOD=1.0 x 10(-8)M). The CGE was used as a proper detection system in flow-injection potentiometry (FIP) with a linear Nernstian range of 3.2 x 10(-8) to 1.4 x 10(-1)M (LOD=1.3 x 10(-8)M). The optimum pH range was 3.5-7.6. The electrodes revealed fairly good discriminating ability towards Cd(2+) in comparison with a large number of alkali, alkaline earth, transition and heavy metal ions. The electrodes found to be chemically inert, showing a fast response time of <5s, and could be used practically over a period of about 2-3 months. The practical utility of the proposed system has also been reported.

  20. Potentiometric determination of the 'formal' hydrolysis ratio of aluminium species in aqueous solutions

    International Nuclear Information System (INIS)

    Fournier, Agathe C.; Shafran, Kirill L.; Perry, Carole C.

    2008-01-01

    The 'formal' hydrolysis ratio (h = C(OH - ) added /C(Al) total ) of hydrolysed aluminium-ions is an important parameter required for the exhaustive and quantitative speciation-fractionation of aluminium in aqueous solutions. This paper describes a potentiometric method for determination of the formal hydrolysis ratio based on an automated alkaline titration procedure. The method uses the point of precipitation of aluminium hydroxide as a reference (h = 3.0) in order to calculate the initial formal hydrolysis ratio of hydrolysed aluminium-ion solutions. Several solutions of pure hydrolytic species including aluminium monomers (AlCl 3 ), Al 13 polynuclear cluster ([Al 13 O 4 (OH) 24 (H 2 O) 12 ] 7+ ), Al 30 polynuclear cluster ([Al 30 O 8 (OH) 56 (H 2 O) 26 ] 18+ ) and a suspension of nanoparticulate aluminium hydroxide have been used as 'reference standards' to validate the proposed potentiometric method. Other important variables in the potentiometric determination of the hydrolysis ratio have also been optimised including the concentration of aluminium and the type and strength of alkali (Trizma-base, NH 3 , NaHCO 3 , Na 2 CO 3 and KOH). The results of the potentiometric analysis have been cross-verified by quantitative 27 Al solution nuclear magnetic resonance ( 27 Al NMR) measurements. The 'formal' hydrolysis ratio of a commercial basic aluminium chloride has been measured as an example of a practical application of the developed technique

  1. Numerical simulation of effects of a non-ionized fluid injection and suction on the MHD flow in a circular channel

    International Nuclear Information System (INIS)

    Rahimi Eosboee, M.; Pourmahmoud, N.; Mirzaie, I.; Mohajeri Khameneh, P.; Majidyfar, S.

    2012-01-01

    Control of a fluid flow velocity profile by injection and suction of a non-ionized fluid in presence of a uniform steady magnetic field has important technical applications. In this paper, the unsteady incompressible and viscous conducting fluid flow has been investigated in a circular channel. The channel walls are assumed to be non-conducting and porous. They are subjected to a uniform steady magnetic field which is perpendicular to the axis of channel, then and suction and injection are applied at the walls. The well known equations of Magnetohydrodynamics are governed to the motion of an electrically conducting fluid flow that is subjected to magnetic field. The numerical solution is carried out by finite difference approach. The results of present numerical simulation shown that the flow injection and suction through the wall can be controlled effectively, the main flow in channel especially in industrial purposes. The results are obtained for different values of the injected and sucked non-ionized flow rate and the effect of Hartman number on the velocity profile is investigated. Finally, a good agreement is seen between the presented results and the corresponding data of finite element method.

  2. Potentiometric determination of trace amounts of volatile thiols in natural gas

    International Nuclear Information System (INIS)

    Farroha, S.M.; Habboush, A.E.; Kurthab, S.Y.

    1986-01-01

    A potentiometric titration method was developed for the determination of volatile thiols in natural gas. An apparatus was devised for the quantitative absorption of volatile thiols. The measurements were performed in an ethanolic ammonium buffer solution containing a known amount of silver nitrate as supporting electrolyte. The excess silver was precipitated by a known amount of potassium iodide. The excess of iodide was back titrated potentiometrically with a standard solution of silver nitrate. The direct titration of the excess silver ions with a standard solution of potassium iodide gave a poor accuracy compared with the back titration method. Iodide selective electrode was employed as an indicator electrode and a silver-silver chloride electrode as reference electrode. The accuracy and reproducibility of the method were established by preparing several synthetic samples in which ethanthiol containing from 346.61 to 12.11 μUg mercaptan sulfur was taken as standard nitrogen as carrier gas with an optimum flow rate of 31.5 L/hr. The results obtained expressed in the form of Grans plot showed an error ranging from 0.16 to 2.39% by weight and the relative standard deviation did not exceed 2.20%. The amount of mercaptan sulfur determined in Iraqi natural gas taken directly in a cylinder from Dora refinery, Baghdad, Iraq, and after six months of storage we 23.15 Ug/L and 21.25 Ug/L respectively with a relative standard deviation not exceeded 1%. The interferences of hydrogen sulfide could be eliminated by absorption in cadimium acetate containing solution. Other sulfur containing compounds e.g. disulfides, sulfoxides which may be present in natural gas do not interfere with the analysis

  3. Dispersion-convolution model for simulating peaks in a flow injection system.

    Science.gov (United States)

    Pai, Su-Cheng; Lai, Yee-Hwong; Chiao, Ling-Yun; Yu, Tiing

    2007-01-12

    A dispersion-convolution model is proposed for simulating peak shapes in a single-line flow injection system. It is based on the assumption that an injected sample plug is expanded due to a "bulk" dispersion mechanism along the length coordinate, and that after traveling over a distance or a period of time, the sample zone will develop into a Gaussian-like distribution. This spatial pattern is further transformed to a temporal coordinate by a convolution process, and finally a temporal peak image is generated. The feasibility of the proposed model has been examined by experiments with various coil lengths, sample sizes and pumping rates. An empirical dispersion coefficient (D*) can be estimated by using the observed peak position, height and area (tp*, h* and At*) from a recorder. An empirical temporal shift (Phi*) can be further approximated by Phi*=D*/u2, which becomes an important parameter in the restoration of experimental peaks. Also, the dispersion coefficient can be expressed as a second-order polynomial function of the pumping rate Q, for which D*(Q)=delta0+delta1Q+delta2Q2. The optimal dispersion occurs at a pumping rate of Qopt=sqrt[delta0/delta2]. This explains the interesting "Nike-swoosh" relationship between the peak height and pumping rate. The excellent coherence of theoretical and experimental peak shapes confirms that the temporal distortion effect is the dominating reason to explain the peak asymmetry in flow injection analysis.

  4. Theoretical Study on the Flow of Refilling Stage in a Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Sang [Halla Univ. Daejeon (Korea, Republic of)

    2017-10-15

    In this study, a theoretical analysis was performed to the flow of refilling stage in a safety injection tank, which is the core cooling system of nuclear power plant in an emergency. A theoretical model was proposed with a nonlinear governing equation defining on the flow of the refilling process of the coolant. Utilizing the Taylor-series expansion, the 1st - order approximation flow equation was obtained, along with its analytic solution of closed type, which could predict accurately the variations of free surface height and flow rate of the coolant. The availability of theoretical result was confirmed by comparing with previous experimental results.

  5. Water-level trends and potentiometric surfaces in the Nacatoch Aquifer in northeastern and southwestern Arkansas and in the Tokio Aquifer in southwestern Arkansas, 2014–15

    Science.gov (United States)

    Rodgers, Kirk D.

    2017-09-20

    The Nacatoch Sand in northeastern and southwestern Arkansas and the Tokio Formation in southwestern Arkansas are sources of groundwater for agricultural, domestic, industrial, and public use. Water-level altitudes measured in 51 wells completed in the Nacatoch Sand and 42 wells completed in the Tokio Formation during 2014 and 2015 were used to create potentiometric-surface maps of the two areas. Aquifers in the Nacatoch Sand and Tokio Formation are hereafter referred to as the Nacatoch aquifer and the Tokio aquifer, respectively.Potentiometric surfaces show that groundwater in the Nacatoch aquifer flows southeast toward the Mississippi River in northeastern Arkansas. Groundwater flow direction is towards the south and southeast in Hempstead, Little River, and Nevada Counties in southwestern Arkansas. An apparent cone of depression exists in southern Clark County and likely alters groundwater flow from a regional direction toward the depression.In southwestern Arkansas, potentiometric surfaces indicate that groundwater flow in the Tokio aquifer is towards the city of Hope. Northwest of Hope, an apparent cone of depression exists. In southwestern Pike, northwestern Nevada, and northeastern Hempstead Counties, an area of artesian flow (water levels are at or above land surface) exists.Water-level changes in wells were identified using two methods: (1) linear regression analysis of hydrographs from select wells with a minimum of 20 years of water-level data, and (2) a direct comparison between water-level measurements from 2008 and 2014–15 at each well. Of the six hydrographs analyzed in the Nacatoch aquifer, four indicated a decline in water levels. Compared to 2008 measurements, the largest rise in water levels was 35.14 feet (ft) in a well in Clark County, whereas the largest decline was 14.76 ft in a well in Nevada County, both located in southwestern Arkansas.Of the four hydrographs analyzed in the Tokio aquifer, one indicated a decline in water levels, while

  6. Wavelet transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  7. Wavelett transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  8. Design and evaluation of potentiometric principles for bladder volume monitoring: a preliminary study.

    Science.gov (United States)

    Chen, Shih-Ching; Hsieh, Tsung-Hsun; Fan, Wen-Jia; Lai, Chien-Hung; Chen, Chun-Lung; Wei, Wei-Feng; Peng, Chih-Wei

    2015-06-01

    Recent advances in microelectronics and wireless transmission technology have led to the development of various implantable sensors for real-time monitoring of bladder conditions. Although various sensing approaches for monitoring bladder conditions were reported, most such sensors have remained at the laboratory stage due to the existence of vital drawbacks. In the present study, we explored a new concept for monitoring the bladder capacity on the basis of potentiometric principles. A prototype of a potentiometer module was designed and fabricated and integrated with a commercial wireless transmission module and power unit. A series of in vitro pig bladder experiments was conducted to determine the best design parameters for implementing the prototype potentiometric device and to prove its feasibility. We successfully implemented the potentiometric module in a pig bladder model in vitro, and the error of the accuracy of bladder volume detection was design principles and animal experience gathered from this research can serve as a basis for developing new implantable bladder sensors in the future.

  9. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    Science.gov (United States)

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. A novel approach for determination of free fatty acids in vegetable oils by a flow injection system with manual injection.

    Science.gov (United States)

    Ayyildiz, H Filiz; Kara, Huseyin; Sherazi, S T H

    2011-12-01

    A non-aqueous flow injection method for determining free fatty acid (FFA) content in corn and sunflower oil samples was developed. A single-line manifold system was built by modification of an HPLC for flow injection analysis (FIA). Without pre-treatment, oil samples were injected into a n-propanol solution containing KOH and phenolphthalein (PHP). The main parameters, such as flow rate of carrier phase, length, geometry, inner diameters of the coils and reagent concentration were all optimized. The proposed FIA method was validated for precision, accuracy, linear region, limit of detection (LOD) and limit of quantification (LOQ). The intra- and inter-day measurements of the precision of the method were found to be within the limits of acceptance criteria (RSD analyst. The linear concentration range was calculated as 0.09-1.50 and 0.07-1.40 FFA% for corn and sunflower oils, correspondingly. The LOD and LOQ were found to be 7.53 × 10(-4)-2.28 × 10(-3) oleic acid % and 7.11 × 10(-4)-2.23 × 10(-3) oleic acid % for corn and sunflower oils, respectively. The results were compared with those obtained by the AOCS (Ca-5a-40) method using statistical t and F tests, and a significant difference was not observed between the methods at a 95% confidence level. The proposed method is suitable for quality control of routine applications due to its simplicity, high sample throughput, and economy of solvents and sample, offering considerable promise as a low cost analytical system that needs minimum human intervention over long periods of time.

  11. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    Science.gov (United States)

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  12. Potentiometric sensing of nuclease activities and oxidative damage of single-stranded DNA using a polycation-sensitive membrane electrode.

    Science.gov (United States)

    Ding, Jiawang; Qin, Wei

    2013-09-15

    A simple, general and label-free potentiometric method to measure nuclease activities and oxidative DNA damage in a homogeneous solution using a polycation-sensitive membrane electrode is reported. Protamine, a linear polyionic species, is used as an indicator to report the cleavage of DNA by nucleases such as restriction and nonspecific nucleases, and the damage of DNA induced by hydroxyl radicals. Measurements can be done with a titration mode or a direct detection mode. For the potentiometric titration mode, the enzymatic cleavage dramatically affects the electrostatical interaction between DNA and protamine and thus shifts the response curve for the potentiometric titration of the DNA with protamine. Under the optimized conditions, the enzyme activities can be sensed potentiometrically with detection limits of 2.7×10(-4)U/µL for S1 nuclease, and of 3.9×10(-4)U/µL for DNase I. For the direct detection mode, a biocomplex between protamine and DNA is used as a substrate. The nuclease of interest cleaves the DNA from the protamine/DNA complex into smaller fragments, so that free protamine is generated and can be detected potentiometrically via the polycation-sensitive membrane electrode. Using a direct measurement, the nuclease activities could be rapidly detected with detection limits of 3.2×10(-4)U/µL for S1 nuclease, and of 4.5×10(-4)U/µL for DNase I. Moreover, the proposed potentiometric assays demonstrate the potential applications in the detection of hydroxyl radicals. It is anticipated that the present potentiometric strategy will provide a promising platform for high-throughput screening of nucleases, reactive oxygen species and the drugs with potential inhibition abilities. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Potentiometric Surface of the Magothy Aquifer in Southern Maryland, September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the potentiometric surface of the Magothy aquifer in the Magothy Formation of Late Cretaceous age in Southern Maryland during September 2007. The map is based on water-level measurements in 69 wells. The highest measured water level was 85 feet above sea level near the northern boundary and outcrop area of the aquifer in the north-central part of Anne Arundel County. The potentiometric surface declined towards the south. Local gradients were directed toward the center of a cone of depression in the Waldorf area that developed in response to pumping. Measured ground-water levels were as low as 90 feet below sea level in the Waldorf area.

  14. Numerical simulation of the gas-solid flow in a square circulating fluidized bed with secondary air injection

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhengyang [Harbin Institute of Technology, Harbin (China). Post-doctor Station of Civil Engineering; Harbin Institute of Technology, Harbin (China). Combustion Engineering Research Inst.; Sun, Shaozeng; Zhao, Ningbo; Wu, Shaohua [Harbin Institute of Technology, Harbin (China). Combustion Engineering Research Inst.; Tan, Yufei [Harbin Institute of Technology, Harbin (China). School of Municipal and Environmental Engineering

    2013-07-01

    The dynamic behavior of gas-solid flow in an experimental square circulating fluidized bed setup (0.25 m x 0.25 m x 6.07 m) is predicted with numerical simulation based on the theory of Euler-Euler gas-solid two-phase flow and the kinetic theory of granular flows. The simulation includes the operation cases with secondary injection and without air-staging. The pressure drop profile, local solids concentration and particle velocity was compared with experimental results. Both simulation and experimental results show that solids concentration increases significantly below the secondary air injection ports when air-staging is adopted. Furthermore, the flow asymmetry in the solid entrance region of the bed was investigated based on the particle concentration/velocity profile. The simulation results are in agreement with the experimental results qualitatively.

  15. Minicolumn field preconcentration and flow-injection flame atomic absorption spectrometric determination of cadmium in seawater

    International Nuclear Information System (INIS)

    Yebra-Biurrun, M.C.; Moreno-Cid, A.; Puig, L.

    2004-01-01

    A simple method for the continuous field preconcentration of trace dissolved cadmium in seawater samples has been developed based on the minicolumn field sampling technique. For this purpose, minicolumns containing Chelite P (aminomethylphosphonic groups) were connected to a field flow preconcentration system (FFPS). Once in the laboratory, these minicolumns are sequentially inserted into a flow-injection system for on-line cadmium elution and detection by flame atomic absorption spectrometry. Factorial designs have been used to optimise the FFPS and the flow-injection elution process. Six experimental variables were optimised: sample pH, sample flow-rate, eluent concentration, eluent volume, eluent flow-rate and minicolumn diameter. The detection limit (3F) of the procedure was 2.7 ng l -1 for a sample volume of 300 ml. The precision (expressed as relative standard deviation) for 11 independent determinations was 0.5-9.4% for cadmium solutions of 10-300 ng l -1 . Analysis of certified reference materials (SLEW-3 and NASS-5) showed good agreement with the certified values. This procedure has been successfully applied to the determination of cadmium in seawater samples from Galicia (Spain)

  16. Numerical simulation of flow characteristics of lean jet to cross-flow in safety injection of reactor cooling system

    International Nuclear Information System (INIS)

    Wang Haijun; He Huining; Luo Yushan; Wang Weishu

    2011-01-01

    In the present work, a numerical simulation was performed to study the flow characteristics of lean jet to cross flow in a main tube in the safety injection of reactor cooling system. The influence scope and mixing characteristics of the confined lean jet in cross-flow were studied. It can be concluded that three basic flow regimes are marked, namely the attached lean jet, lift-off lean jet and impinging lean jet. The velocity ratio V R is the key factor in the flow state. The depth and region of jet to main flow are enhanced with the increase of the velocity ratio. The jet flow penetrates through the main flow with the increase of the velocity ratio. At higher velocity ratio, the jet flow strikes the main flow bottom and circumfluence happens in upriver of main flow. The vortex flow characteristics dominate the flow near region of jet to cross-flow and the mixture of jet to cross-flow. At different velocity ratio V R , the vortex grows from the same displacement, but the vortex type and the vortex is different. At higher velocity ratio, the vortex develops fleetly, wears off sharp and dies out sharp. The study is very important to the heat transfer experiments of cross-flow jet and thermal stress analysis in the designs of nuclear engineering. (authors)

  17. A study on nozzle flow and spray characteristics of piezo injector for next generation high response injection

    International Nuclear Information System (INIS)

    Lee, Jin Wook; Min, Kyoung Doug

    2006-01-01

    Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(Volume Of Fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response in a piezo-driven injector were reflected to spray development in agreement with the experimental spray images

  18. Semi-automated potentiometric titration method for uranium characterization

    Energy Technology Data Exchange (ETDEWEB)

    Cristiano, B.F.G., E-mail: barbara@ird.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Delgado, J.U.; Silva, J.W.S. da; Barros, P.D. de; Araujo, R.M.S. de [Comissao Nacional de Energia Nuclear (CNEN), Instituto de Radioprotecao e Dosimetria (IRD), Avenida Salvador Allende s/n Recreio dos Bandeirantes, PO Box 37750, Rio de Janeiro, 22780-160 RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear (PEN/COPPE), Universidade Federal do Rio de Janeiro (UFRJ), Ilha do Fundao, PO Box 68509, Rio de Janeiro, 21945-970 RJ (Brazil)

    2012-07-15

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. - Highlights: Black-Right-Pointing-Pointer We developed a semi-automatic version of potentiometric titration method. Black-Right-Pointing-Pointer The method is used for certification and characterization of uranium compounds. Black-Right-Pointing-Pointer The traceability of the method was assured by a K{sub 2}Cr{sub 2}O{sub 7} primary standard. Black-Right-Pointing-Pointer The results of U{sub 3}O{sub 8} reference material analyzed was consistent with certified value. Black-Right-Pointing-Pointer The uncertainty obtained, near 0.01%, is useful for characterization purposes.

  19. [Studies on a sequential injection renewable surface reflectance spectrophotometric system using a microchip flow cell].

    Science.gov (United States)

    Wang, Jian-ya; Fang, Zhao-lun

    2002-02-01

    A microchip flow cell was developed for flow injection renewable surface assay by reflectance spectrophotometry. The flow cell was coupled to a sequential injection system and optical fiber photometric detection system. The flow cell featured a three-layer structure. The flow channel was cut into a silicone rubber membrance which formed the middle layer, and a porous filter was inlayed across a widened section of the channel to trap microbeads introduced into the flow cell. The area of the detection window of the flow cell was approximately 3.6 mm2, the volume of the bead trapped in the flow cell was 2.2 microL, the depth of the bead layer was 600 microns. A multistrand bifurcated optical fiber was coupled with incident light, detector and flow cell. The chromogenic reaction of Cr(VI) with 1,5-diphenylcarbohydrazide (DPC) which was adsorbed on trapped Polysorb C-18 beads was used as a model reaction to optimize the flow cell design and the experimental system. The reflectance of the renewable reaction surface was monitored at 540 nm. With 100 microL sample loaded and 1.0 mL.min-1 carrier flow rate, the linear response range was 0-0.6 microgram.mL-1 Cr(VI). A detection limit (3 sigma) of 6 ng.mL-1, precision of 1.5% RSD(n = 11), and a throughput of 64 samples per hour were achieved. Considerations in system and flow cell design, the influence of depth of the bead layer, weight of beads used, and the flow rates of carrier stream on the performance were discussed.

  20. Magnetohydrodynamics effect on three-dimensional viscous incompressible flow between two horizontal parallel porous plates and heat transfer with periodic injection/suction

    Directory of Open Access Journals (Sweden)

    R. C. Chaudhary

    2004-11-01

    Full Text Available We investigate the hydromagnetic effect on viscous incompressible flow between two horizontal parallel porous flat plates with transverse sinusoidal injection of the fluid at the stationary plate and its corresponding removal by periodic suction through the plate in uniform motion. The flow becomes three dimensional due to this injection/suction velocity. Approximate solutions are obtained for the flow field, the pressure, the skin-friction, the temperature field, and the rate of heat transfer. The dependence of solution on M (Hartmann number and λ (injection/suction is investigated by the graphs and tables.

  1. A microfabricated electroosmotic pump coupled to a gas-diffusion microchip for flow injection analysis of ammonia

    International Nuclear Information System (INIS)

    Zhu, Zaifang; Lu, Joann J.; Liu, Shaorong; Almeida, M. Inês G. S.; Kolev, Spas D.; Pu, Qiaosheng

    2015-01-01

    We have microfabricated two functional components toward developing a microchip flow injection analysis (FIA) system, i.e., an open-channel electroosmotic pump and a gas-diffusion chip, consisting of two microfabricated glass wafers and a porous polytetrafluoroethylene membrane. This is the first application of gas-diffusion separation in a microchip FIA system. To demonstrate the feasibility of using these two components for performing gas-diffusion FIA, we have incorporated them together with a regular FIA injection valve and a capillary electrophoresis absorbance detector in a flow injection system for determination of ammonia in environmental water samples. This system has a limit of detection of 0.10 mg L −1 NH 3 , with a good repeatability (relative standard deviation of less than 5 % for 4.0 mg L −1 NH 3 ). Parameters affecting its performance are also discussed. (author)

  2. Descriptions and characterizations of water-level data and groundwater flow for the Brewster Boulevard and Castle Hayne Aquifer Systems and the Tarawa Terrace Aquifer

    Science.gov (United States)

    Faye, Robert E.; Jones, L. Elliott; Suárez-Soto, René J.

    2013-01-01

    This supplement of Chapter A (Supplement 3) summarizes results of analyses of groundwater-level data and describes corresponding elements of groundwater flow such as vertical hydraulic gradients useful for groundwater-flow model calibration. Field data as well as theoretical concepts indicate that potentiometric surfaces within the study area are shown to resemble to a large degree a subdued replica of surface topography. Consequently, precipitation that infiltrates to the water table flows laterally from highland to lowland areas and eventually discharges to streams such as Northeast and Wallace Creeks and New River. Vertically downward hydraulic gradients occur in highland areas resulting in the transfer of groundwater from shallow relatively unconfined aquifers to underlying confined or semi-confined aquifers. Conversely, in the vicinity of large streams such as Wallace and Frenchs Creeks, diffuse upward leakage occurs from underlying confined or semi-confined aquifers. Point water-level data indicating water-table altitudes, water-table altitudes estimated using a regression equation, and estimates of stream levels determined from a digital elevation model (DEM) and topographic maps were used to estimate a predevelopment water-table surface in the study area. Approximate flow lines along hydraulic gradients are shown on a predevelopment potentiometric surface map and extend from highland areas where potentiometric levels are greatest toward streams such as Wallace Creek and Northeast Creek. The distribution of potentiometric levels and corresponding groundwater-flow directions conform closely to related descriptions of the conceptual model.

  3. Exact solution for flow in a porous pipe with unsteady wall suction and/or injection

    Science.gov (United States)

    Tsangaris, S.; Kondaxakis, D.; Vlachakis, N. W.

    2007-10-01

    This paper presents an extension of the exact solution of the steady laminar axisymmetric flow in a straight pipe of circular cross section with porous wall, given by R.M. Terrill, to the case of unsteady wall injection and/or suction. The cases of the pulsating parabolic profile and of the developed pulsating flow are investigated as examples. The pulsating flow in porous ducts has many applications in biomedical engineering and in other engineering areas.

  4. Rapid determination of 99Tc in environmental samples by high resolution ICP-MS coupled with on-line flow injection system

    International Nuclear Information System (INIS)

    Kim, C.K.; Kim, C.S.; Rho, B.H.; Lee, J.I.

    2002-01-01

    High resolution inductively coupled plasma mass spectrometry coupled with an on-line flow injection system (FI-HR-ICP-MS) was applied to determine the ultra-trace level 99 Tc in soil. The flow injection system (PrepLab TM ) was composed of two TEVA-Spec R resins, reduced remarkably the sample amounts and the analysis time, compared to the conventional analytical methods. In the flow injection system, Mo and Ru were sufficiently eliminated by using the flow injection system, with the decontamination factors of 1.6 x 10 4 and 9.9 x 10 5 , respectively. With the present method, it was possible to determine ultra-low level of 99 Tc in 3∼6 soil at 3-5 hours of analysis time per sample. The relative standard deviation for each sample was less than 4%. The detection limits for 99 Tc was 85 fg x ml -1 (0.05 mBq x ml -1 ), which was calculated from the three times standard deviation of the count rate of the blank. (author)

  5. Flow Injection and Atomic Absorption Spectrometry - An Effective and Attractive Analytical Chemical Combination

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Nielsen, Steffen

    1998-01-01

    One of the advantages of the flow injection (FI) concept is that it is compatible with virtually all detection techniques. Being a versatile vehicle for enhancing the performance of the individual detection devices, the most spectacular results have possibly been obtained in conjunction with atom...

  6. AAO-CNTs electrode on microfluidic flow injection system for rapid iodide sensing.

    Science.gov (United States)

    Phokharatkul, Ditsayut; Karuwan, Chanpen; Lomas, Tanom; Nacapricha, Duangjai; Wisitsoraat, Anurat; Tuantranont, Adisorn

    2011-06-15

    In this work, carbon nanotubes (CNTs) nanoarrays in anodized aluminum oxide (AAO-CNTs) nanopore is integrated on a microfluidic flow injection system for in-channel electrochemical detection of iodide. The device was fabricated from PDMS (polydimethylsiloxane) microchannel bonded on glass substrates that contains three-electrode electrochemical system, including AAO-CNTs as a working electrode, silver as a reference electrode and platinum as an auxiliary electrode. Aluminum, stainless steel catalyst, silver and platinum layers were sputtered on the glass substrate through shadow masks. Aluminum layer was then anodized by two-step anodization process to form nanopore template. CNTs were then grown in AAO template by thermal chemical vapor deposition. The amperometric detection of iodide was performed in 500-μm-wide and 100-μm-deep microchannels on the microfluidic chip. The influences of flow rate, injection volume and detection potential on the current response were optimized. From experimental results, AAO-CNTs electrode on chip offers higher sensitivity and wider dynamic range than CNTs electrode with no AAO template. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Stopped-flow injection method for determination of phosphate in soils and fertilisers

    Directory of Open Access Journals (Sweden)

    Jaroon Jakmunee

    2008-02-01

    Full Text Available A stopped-flow injection system for the determination of phosphate has been developed. It involves the phosphate-molybdate-ascorbic acid reactions in the molybdenum blue method. The system is controlled by a semi-automatic stopped-FI analyser with a light emitting diode (LED-colorimeter for monitoring the absorbance change relating to the concentration of a reaction product formed during the stopping period while the injected zone of a standard or sample is being in the flow cell. The slope of the FIAgram obtained is linearly proportional to the reaction rate, which depends on the phosphate concentration. Effects of concentration of reagents, viz. sodium molybdate, ascorbic acid and nitric acid, on the slope of the FIAgram were studied. The suitable concentration is 0.02 M, 0.25 %w/v and 0.15 M, respectively. A linear calibration graph in the range of 0.3-6.0 mg P L-1 was employed for the determination of phosphate in soil and fertiliser samples. The results obtained agree well with those from a standard spectrophotometric method.

  8. A Urea Potentiometric Biosensor Based on a Thiophene Copolymer

    Directory of Open Access Journals (Sweden)

    Cheng-Yuan (Kevin Lai

    2017-03-01

    Full Text Available A potentiometric enzyme biosensor is a convenient detector for quantification of urea concentrations in industrial processes, or for monitoring patients with diabetes, kidney damage or liver malfunction. In this work, poly(3-hexylthiophene-co-3-thiopheneacetic acid (P(3HT-co-3TAA was chemically synthesized, characterized and spin-coated onto conductive indium tin oxide (ITO glass electrodes. Urease (Urs was covalently attached to the smooth surface of this copolymer via carbodiimide coupling. The electrochemical behavior and stability of the modified Urs/P(3HT-co-3TAA/ITO glass electrode were investigated by cyclic voltammetry, and the bound enzyme activity was confirmed by spectrophotometry. Potentiometric response studies indicated that this electrode could determine the concentration of urea in aqueous solutions, with a quasi-Nernstian response up to about 5 mM. No attempt was made to optimize the response speed; full equilibration occurred after 10 min, but the half-time for response was typically <1 min.

  9. Determination of water traces in various organic solvents using Karl Fischer method under FIA conditions.

    Science.gov (United States)

    Dantan, N; Frenzel, W; Küppers, S

    2000-05-31

    Flow injection methods utilising the Karl Fischer (KF) reaction with spectrophotometric and potentiometric detection are described for the determination of the trace water content in various organic solvents. Optimisation of the methods resulted in an accessible (linear) working range of 0.01-0.2% water for many solvents studied with a typical precision of 1-2% R.S.D. Only 50 mul of organic solvent was injected and the sampling frequency was about 120 samples per h. Since the slopes of the calibration curves were different for different solvents appropriate calibration was required. Problems associated with spectrophotometric detection and caused by refractive index changes were pointed out and a nested-loop configuration was proposed to overcome this kind of interference. The potentiometric method with a novel flow-through detector cell was shown to surpass the performance of spectrophotometric detection in any respect. The characteristics of the procedures developed made them well applicable for on-line monitoring of technical solvent distillations in an industrial plant.

  10. Potentiometric titration curves of aluminium salt solutions and its species conversion in the hydrolysis-polymerization course

    Directory of Open Access Journals (Sweden)

    Chenyi Wang

    2008-12-01

    Full Text Available A new concept of critical point is expounded by analysing the potentiometric titration curves of aluminium salt solutions under the moderate slow rate of base injection. The critical point is defined as the characteristic spot of the Al3+ salt solutions potentiometric titration curve, which is related to the experiment conditions. In addition, the changes of critical points reflect the influence of experiment conditions on the course of the hydrolysis-polymerization and the conversion of hydroxyl polynuclear aluminum species. According to the OH/Al mole ratio, the Al species can be divided into four regions quantitatively by three characteristic points on the titration curves: Part I, Al3+/Ala region, consist chiefly of Al3+ and mononuclear Al; Part II, the small/middle polynuclear Al region, including Al2-Al12; Part III, the large-size polynuclear aluminum region, consistent with predominantly Al13-Al54 and a little sol/gel Al(OH3; Part IV, the dissolving region of sol/gel Alc, only Al(OH 3 (aq or am and Al(OH4- species, which set up a base to study on the hydrolysis-polymerization of Al3+. At the same time, significant effects of total aluminum concentration, temperature, halide ion, silicate radical, and organic acid radical on the titration curves and its critical points were observed. Given the three critical points which demarcating the aluminum forms, we carry out a through investigation into the fundamental regulations of these factors’ influence, and offer a fresh train of thought to study the hydrolysis-polymerization of Al3+ in soil solutions.

  11. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    Science.gov (United States)

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  12. The determination of uranium(VI) by flow-injection analysis

    International Nuclear Information System (INIS)

    Jones, E.A.

    1985-01-01

    A method is described for the direct determination of uranium(VI) in waste waters and acid leach liquors by use of a flow-injection procedure and spectrophotometric measurement with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (bromo-PADAP). The interference effects of several commonly occurring elements were studied. The calibration curve is linear over concentrations of uranium(VI) from 0,5 to 20 mg/1, and the precision obtained on a synthetic leach liquor was 0,019 (relative standard deviation). The procedure is rapid and convenient, and up to 40 samples can be analysed in an hour

  13. Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes.

    Science.gov (United States)

    Guinovart, Tomàs; Parrilla, Marc; Crespo, Gastón A; Rius, F Xavier; Andrade, Francisco J

    2013-09-21

    A simple and generalized approach to build electrochemical sensors for wearable devices is presented. Commercial cotton yarns are first turned into electrical conductors through a simple dyeing process using a carbon nanotube ink. These conductive yarns are then partially coated with a suitable polymeric membrane to build ion-selective electrodes. Potentiometric measurements using these yarn-potentiometric sensors are demonstrated. Examples of yarns that can sense pH, K(+) and NH4(+) are presented. In all cases, these sensing yarns show limits of detection and linear ranges that are similar to those obtained with lab-made solid-state ion-selective electrodes. Through the immobilization of these sensors in a band-aid, it is shown that this approach could be easily implemented in a wearable device. Factors affecting the performance of the sensors and future potential applications are discussed.

  14. Spectrophotometric, potentiometric, and gravimetric determination of lanthanides with peri-dihydroxynaphthindenone

    International Nuclear Information System (INIS)

    Hassan, S.S.M.; Mahmoud, W.H.

    1982-01-01

    Sensitive and reasonably selective methods are described for the spectrophotometric, potentiometric, and gravimetric determination of lanthanides using peri-dihydroxynaphthindenone as a novel chromogenic and precipitating reagent. The reagent forms a stable 1:2 (metal:reagent) type of complex with light lanthanides at pH 2-7 in 1:1 ethanol-water mixture. Low metal concentrations ( 4 L mol -1 cm -1 ) which obey Beer's law. Quantitative precipitation of the complexes from metal solutions of concentrations > 100 μg/mL permits both gravimetric quantitation by igniting the precipitates to the metal oxides and potentiometric titration of the excess reagent. Results with an average recovery of 98% (standard deviation 0.7%) are obtainable for 0.1 μg to 200 mg of all light lanthanides. Many foreign ions naturally occurring or frequently associated with lanthanides do not interfere or can be tolerated

  15. Numerical Simulation of Magnetic Nanoparticles Injection into Two–phase Flow in a Porous Medium

    KAUST Repository

    El-Amin, Mohamed; Saad, Ahmed M.; Sun, Shuyu; Salama, Amgad

    2017-01-01

    In this paper, the problem of magnetic nanoparticles injection into a water–oil two–phase flow under an external permanent magnetic field is investigated. The mathematical model of the problem under consideration has been developed. We treat

  16. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sklenářová, Hana, E-mail: sklenarova@faf.cuni.cz [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic); Voráčová, Ivona [Institute of Analytical Chemistry of the CAS, v. v. i., Brno (Czech Republic); Chocholouš, Petr; Polášek, Miroslav [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic)

    2017-04-15

    The effect of 0.01–100 µmol L{sup −1} Quantum Dots (QDs) with different emission wavelengths (520–640 nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow-batch detection cell operated in flow and stop-flow modes. In permanganate CL system no significant enhancement of the CL signal was observed while for the luminol–hydrogen peroxide CL substantial increase (>100% and >90% with the spiral detection cell in flow and stop-flow modes, respectively) was attained for CdTe QDs. Enhancement exceeding 120% was observed for QDs with emissions at 520, 575 and 603 nm (sizes of 2.8 nm, 3.3 nm and 3.6 nm) using the flow-batch detection cell in the stop-flow mode. Pronounced effect was noted for surface modifications while mercaptoethylamine was the most efficient in CL enhancement compared to mercaptopropionic acid the most commonly applied coating. Significant difference between results obtained in flow and flow-batch conditions based on the entire kinetics of the extremely fast CL reaction was discussed. The increase of the CL signal was always accompanied by reduced lifetime of the CL emission thus application of QDs in flow techniques should be always coupled with the study of the CL lifetime.

  17. A study on nozzle flow and spray characteristics of piezo injector for next generation high response injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Wook [Korea Institue of Machinery and Materials, Daejeon (Korea, Republic of); Min, Kyoung Doug [Seoul National University, Seoul (Korea, Republic of)

    2006-06-15

    Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(Volume Of Fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response in a piezo-driven injector were reflected to spray development in agreement with the experimental spray images.

  18. Potentiometric determination of hexavalent uranium in uranium silicide samples

    International Nuclear Information System (INIS)

    Arlegui, Oscar

    1999-01-01

    The Chilean Nuclear Energy Commission's Department of Nuclear Materials has among its projects the production of fuels elements for nuclear reactors, and, therefore, the Chemical Analysis Laboratory must have a rapid and reliable method for uranium analysis, to control the uranium concentration during each stage of the production process. For this reason the Chilean Nuclear Energy Commission's Chemical Analysis Laboratory has validated a potentiometric method, which is a modification of the Davies and Gray method proposed by A.R. Eberle. This method uses the Potentiometric Titration Technique and is based on the direct and rapid reduction of uranium (VI) to Uranium (IV), in a concentrated phosphoric acid medium, with excess iron (II) used as a reducing agent. In this medium the excess iron (II) selectively oxidizes to iron (III) with nitric acid, using molybdenum (IV) as a catalyzer, the nitrous acid that is produced is eliminated by adding amidosulfuric acid. The solution is diluted with 1M sulfuric acid and the uranium (IV) obtained is titrated potentiometrically with potassium dichromate in the presence of vanadilic sulfate to obtain a better defined final titration point. The samples were softened with hydrochloric acid and nitric acid and later 50 ml were estimated in a 20% sulfuric acid medium. The analytical method was validated by comparing it with Certified Reference Material (C.R.M.) from the New Brunswick Laboratory (NBL), Metallic Uranium, CRM 112-A. The F Test and the T Test show that the value calculated is less than the tabulated value so the result is traceable to the reference material. The quantification limit, sensitivity, precision and accuracy were quantified for the method

  19. Start-up assist by magnetized plasma flow injection in TPE-RX reversed-field pinch

    Energy Technology Data Exchange (ETDEWEB)

    Asai, T. [College of Science and Technology, Nihon University, 1-8 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8308 (Japan)]. E-mail: asai@phys.cst.nihon-u.ac.jp; Nagata, M. [Graduate School of Engineering, University of Hyogo, Himeji (Japan); Koguchi, H. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Hirano, Y. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Sakakita, H. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Yambe, K. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Kiyama, S. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan)

    2006-11-15

    A reversed-field pinch (RFP) start-up assisted by a magnetized plasma flow injection was demonstrated for the first time on a TPE-RX machine. This sequence of experiments aimed to establish a new method of ionization, gas-fill and helicity injection in the start-up phase of an RFP. In this start-up method, magnetized and well-ionized plasma is formed by a magnetized coaxial plasma gun and injected into the torus chamber as an initial pre-ionized plasma for RFP formation. In the initial experiments, attenuated density pump-out and comparatively slow decay of the toroidal flux and plasma current were observed as evidence of its being an effective start-up method.

  20. The Optimisation of Processing Condition for Injected Mould Polypropylene-Nanoclay-Gigantochloa Scortechinii based on Melt Flow Index

    Science.gov (United States)

    Othman, M. H.; Rosli, M. S.; Hasan, S.; Amin, A. M.; Hashim, M. Y.; Marwah, O. M. F.; Amin, S. Y. M.

    2018-03-01

    The fundamental knowledge of flow behaviour is essential in producing various plastic parts injection moulding process. Moreover, the adaptation of advanced polymer-nanocomposites such as polypropylene-nanoclay with natural fibres, for instance Gigantochloa Scortechinii may boost up the mechanical properties of the parts. Therefore, this project was proposed with the objective to optimise the processing condition of injected mould polypropylene-nanoclay-Gigantochloa Scortechini fibres based on the flow behaviour, which was melt flow index. At first, Gigantochloa Scortechinii fibres have to be preheated at temperature 120°C and then mixed with polypropylene, maleic anhydride modified polypropylene oligomers (PPgMA) and nanoclay by using Brabender Plastograph machine. Next, forms of pellets were produced from the samples by using Granulator machine for use in the injection moulding process. The design of experiments that was used in the injection moulding process was Taguchi Method Orthogonal Array -L934. Melt Flow Index (MF) was selected as the response. Based on the results, the value of MFI increased when the fiber content increase from 0% to 3%, which was 17.78 g/10min to 22.07 g/10min and decreased from 3% to 6%, which was 22.07 g/10min to 20.05 g/10min and 3%, which gives the highest value of MFI. Based on the signal to ratio analysis, the most influential parameter that affects the value of MFI was the melt temperature. The optimum parameter for 3% were 170°C melt temperature, 35% packing pressure, 30% screw speed and 3 second filling time.

  1. Assessment of effect of intravitreal ranibizumab injection on the ocular blood flow in patients with neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    V. V. Neroev

    2014-07-01

    Full Text Available Purpose: To evaluate the effect of intravitreal ranibizumab injection on the ocular blood flow in patients with neovascular agerelatedmacular degeneration (AMD.Methods: 35 patients with wet AMD undergone intravitreal 0.5 mg ranibizumab injection. Color Doppler Imaging (CDI and dopplerographywere used to measure hemodynamic parameters including the peak systolic velocity (Vsyst, cm / s, end-diastolic velocity (V diast, cm / s, and resistance index (RI of blood flow in the central retinal artery (CRA, the short posterior ciliary arteries (PCA, and the ophthalmic artery (OA. All patients were examined before and after injection on day 1‑7 and 30 day during the 3‑month follow up period.Results: Before intravitreal injection Vsyst was decreased in short PCA (p<0.05, RI in CRA and in short PCA significantly increased in comparison with normal index in same vessels. The peak systolic velocity in OA, in CRA and in short PCA was not significantly changed. After second injection resistance index in CRA and in short PCA was normalized.Conclusion: There was not impairment of ocular blood flow in retinal and choroidal after monthly intravitreal injection of ranibizumab during the 3‑month follow up period.

  2. Assessment of effect of intravitreal ranibizumab injection on the ocular blood flow in patients with neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    V. V. Neroev

    2013-01-01

    Full Text Available Purpose: To evaluate the effect of intravitreal ranibizumab injection on the ocular blood flow in patients with neovascular agerelatedmacular degeneration (AMD.Methods: 35 patients with wet AMD undergone intravitreal 0.5 mg ranibizumab injection. Color Doppler Imaging (CDI and dopplerographywere used to measure hemodynamic parameters including the peak systolic velocity (Vsyst, cm / s, end-diastolic velocity (V diast, cm / s, and resistance index (RI of blood flow in the central retinal artery (CRA, the short posterior ciliary arteries (PCA, and the ophthalmic artery (OA. All patients were examined before and after injection on day 1‑7 and 30 day during the 3‑month follow up period.Results: Before intravitreal injection Vsyst was decreased in short PCA (p<0.05, RI in CRA and in short PCA significantly increased in comparison with normal index in same vessels. The peak systolic velocity in OA, in CRA and in short PCA was not significantly changed. After second injection resistance index in CRA and in short PCA was normalized.Conclusion: There was not impairment of ocular blood flow in retinal and choroidal after monthly intravitreal injection of ranibizumab during the 3‑month follow up period.

  3. Modelling and Simulation of Structural Deformation of Isothermal Subsurface Flow and Carbon Dioxide Injection

    KAUST Repository

    El-Amin, Mohamed; Negara, Ardiansyah; Salama, Amgad; Sun, Shuyu

    2011-01-01

    force term. The flux continuity condition is used at interfaces between different permeability layers of the heterogeneous medium. We analyze the vertical migration of a CO2 plume injected into a 2D layered reservoir. Analysis of distribution of flow

  4. Potentiometric study of rare earth complexing with trans-1,2-diaminocyclohexane-N,N'-dimalonic acid

    International Nuclear Information System (INIS)

    Smirnova, T.I.; Gorelov, I.P.

    1980-01-01

    Complexing of rare earths (Ln) and yttrium with trans-1,2-diaminocyclohexane-N, N'-dimalonic acid in aqueous solutions is studied using indirect potentiometric method with an aid of stationary mercury electrode and by the method of pH-potentiometric titration. It is shown that in the investigated solutions the LnL - and LnL 2 5- complexes are formed. At 25 deg C and ion force 0.1 stability constants of the complexes detected are determined [ru

  5. Potentiometric studies on the complexes of tetracycline (TC) and oxytetracycline (OTC) with some metal ions

    International Nuclear Information System (INIS)

    Ghandour, M.A.; Azab, H.A.; Hassan, A.; Ali, A.M.

    1992-01-01

    The interaction of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Zn(II), Cd(II), Hg(II), Pb(II), Al(III), and UO 2 (II) ions with tetracycline (TC) were studied by potentiometric pH titrations. The formation constants of the different binary complexes formed in such systems have been determined at 25±0.1 deg C and μ=0.1 moll -1 (NaNO 3 ). Potentiometric pH equilibrium measurements have been made under the same conditions for the interaction of oxytetracycline (OTC) and Cu(II), Cd(II), Pb(II), and UO 2 (II). The formation of (1:1) binary complexes are inferred from the potentiometric pH titration curves. The protonation constants of TC and OTC were also determined under the same conditions and refined (ESAB2M computer program). The transition metal stability constants are consistent with the Irving-Williams series. (authors)

  6. The determination, by flow-injection analysis, of iron, sulphate, silver and cadmium

    International Nuclear Information System (INIS)

    Jones, E.A.

    1983-01-01

    This report describes the spectrophotometric determination by flow-injection analysis including, where necessary, liquid-liquid extraction of iron with 1,10-phenanthroline; of sulphate by its catalytic effect on the methylthymol blue-zirconium reaction; of silver with bromopyrogallol red and 1,10-phenanthroline; and of cadmium with dithizone. Optimum conditions for each system are established, and sensitivities and ranges of determination are given

  7. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection

    International Nuclear Information System (INIS)

    Morais, Ines P.A.; Miro, Manuel; Manera, Matias; Estela, Jose Manuel; Cerda, Victor; Souto, M. Renata S.; Rangel, Antonio O.S.S.

    2004-01-01

    In this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL-MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 μg P l -1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 μg P l -1 were attained. The flowing stream system handles 11 analysis h -1 and has been successfully applied to the determination of trace levels of

  9. Geostatistical analysis of potentiometric data in Wolfcamp aquifer of the Palo Duro Basin, Texas

    International Nuclear Information System (INIS)

    Harper, W.V.; Furr, J.M.

    1986-04-01

    This report details a geostatistical analysis of potentiometric data from the Wolfcamp aquifer in the Palo Duro Basin, Texas. Such an analysis is a part of an overall uncertainty analysis for a high-level waste repository in salt. Both an expected potentiometric surface and the associated standard error surface are produced. The Wolfcamp data are found to be well explained by a linear trend with a superimposed spherical semivariogram. A cross-validation of the analysis confirms this. In addition, the cross-validation provides a point-by-point check to test for possible anomalous data

  10. Potentiometric Surface of the Magothy Aquifer in Southern Maryland, September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the potentiometric surface of the Magothy aquifer in the Magothy Formation of Late Cretaceous age in Southern Maryland during September 2009. The map is based on water-level measurements in 66 wells. The highest measured water level was 85 feet above sea level near the northern boundary and outcrop area of the aquifer in the north-central part of Anne Arundel County. The potentiometric surface declined towards the south. Local hydraulic gradients were directed toward the center of a cone of depression in the Waldorf area that developed in response to pumping. Measured groundwater levels were as low as 71 feet below sea level in the Waldorf area. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  11. Advancement of In-Flight Alumina Powder Spheroidization Process with Water Droplet Injection Using a Small Power DC-RF Hybrid Plasma Flow System

    Science.gov (United States)

    Jang, Juyong; Takana, Hidemasa; Park, Sangkyu; Nishiyama, Hideya

    2012-09-01

    The correlation between plasma thermofluid characteristics and alumina powder spheroidization processes with water droplet injection using a small power DC-RF hybrid plasma flow system was experimentally clarified. Micro-sized water droplets with a low water flow rate were injected into the tail of thermal plasma flow so as not to disturb the plasma flow directly. Injected water droplets were vaporized in the thermal plasma flow and were transported upstream in the plasma flow to the torch by the backflow. After dissociation of water, the production of hydrogen was detected by the optical emission spectroscopy in the downstream RF plasma flow. The emission area of the DC plasma jet expanded and elongated in the vicinity of the RF coils. Additionally, the emission area of RF plasma flow enlarged and was visible as red emission in the downstream RF plasma flow in the vicinity below the RF coils due to hydrogen production. Therefore, the plasma flow mixed with produced hydrogen increased the plasma enthalpy and the highest spheroidization rate of 97% was obtained at a water flow rate of 15 Sm l/min and an atomizing gas flow rate of 8 S l/min using a small power DC-RF hybrid plasma flow system.

  12. Modelling and Simulation of Structural Deformation of Isothermal Subsurface Flow and Carbon Dioxide Injection

    KAUST Repository

    El-Amin, Mohamed

    2011-05-15

    Injection of CO2 in hydrocarbon reservoir has double benefit. On the one hand, it is a profitable method due to issues related to global warming, and on the other hand it is an effective mechanism to enhance hydrocarbon recovery. Such injection associates complex processes involving, e.g., solute transport of dissolved materials, in addition to local changes in density of the phases. Also, increasing carbon dioxide injection may cause a structural deformation of the medium, so it is important to include such effect into the model. The structural deformation modelling in carbon sequestration is important to evaluate the medium stability to avoid CO2 leakage to the atmosphere. On the other hand, geologic formation of the medium is usually heterogeneous and consists of several layers of different permeability. In this work we conduct numerical simulation of two-phase flow in a heterogeneous porous medium domain with dissolved solute transport as well as structural deformation effects. The solute transport of the dissolved component is described by concentration equation. The structural deformation for geomechanics is derived from a general local differential balance equation with neglecting the local mass balance of solid phase and the inertial force term. The flux continuity condition is used at interfaces between different permeability layers of the heterogeneous medium. We analyze the vertical migration of a CO2 plume injected into a 2D layered reservoir. Analysis of distribution of flow field components such as saturation, pressures, velocities, and CO2 concentration are presented.

  13. An investigation of flow properties of metal matrix composites suspensions for injection molding

    International Nuclear Information System (INIS)

    Ahmad, F.; Bevis, M.J.

    1997-01-01

    Flow properties of metal matrix composites suspensions have significant effects on the fibre orientation during mould filling. The results presented in this paper relate to the flow properties of aluminium powder and glass fibres compounded into a sacrificial thermoplastics binder. For this purpose, a range of aluminium compounds and aluminium composite suspensions were investigated over a wide shear rate range expected to occur during injection mould process. Aluminium composites wee prepared by substituting glass fibres for aluminium in aluminium compound. Aluminium composite containing a maximum critical volume fraction of fibres which did not exhibit an increase n viscosity was determined. The effect of temperature on the flow behaviour of aluminium composite was also investigated. (author)

  14. Direct potentiometric control of chloride-ion content in water coolant of nuclear reactors

    International Nuclear Information System (INIS)

    Moskvin, L.N.; Vilkov, N.Ya.; Krasnoperov, V.M.; Epimakhova, L.V.

    1979-01-01

    The work of automatic chloride measuring device designed for continuous determination of chloride-ion concentration in water coolants of nuclear power plants is investigated. A series of experiments have been performed to investigate a device with sensitive element in the form of potentiometric cell with two flowing porous metal silver electrodes (PSE), placed in series. A calibration circuit of chloride measuring devices and PSE is described. A comparison is made between the results obtained by means of automatic chloride measuring device and results of manual control of samples. A conclusion is drawn that automatic chloride measuring devices meet the requirements of nuclear power plants for methods and instruments of control of chloride-ions microconcentration. The development and implantation of automatic chloride-ion analizers will make the analytical control on nuclear power plants easier and make it possible to obtain more reliable information

  15. Three-dimensional analysis of internal flow characteristics in the injection nozzle tip of direct-injection diesel engines; Sanjigen suchi kaiseki ni yoru DI diesel kikan no nenryo funsha nozzle nai ryudo tokusei no kaimei

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H; Matsui, Y; Kimura, S [Nissan Motor Co. Ltd. Tokyo (Japan)

    1997-10-01

    To reduce the exhaust emissions and fuel consumption of direct-injection diesel engines, it is essential to optimize the fuel injection equipment closely related to combustion and emission characteristics. In this study, three-dimensional computation has been applied to investigate the effects of the injection nozzle specifications (e.g., sac volume, round shape at the inlet of the nozzle hole) and needle tip deviation on internal flow characteristics. The computational results revealed that the effects of the nozzle specifications and needle tip deviation with a smaller needle lift on internal flow characteristics and a general approach to optimize the injection nozzle specifications were obtained. 3 refs., 10 figs., 1 tab.

  16. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  17. How Flow Injection Analysis (FIA) over the past 25 years has changed our way of performing chemical analyses

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2007-01-01

    Briefly looking back on the impact of flow injection analysis (FIA), as reflected in the rapid growth of publications in the scientific literature, and touching upon many of the novel and unique analytical chemical possibilities that FIA and its sequels, sequential injection analysis (SIA) and La...

  18. Potentiometric analytical microsystem based on the integration of a gas-diffusion step for on-line ammonium determination in water recycling processes in manned space missions.

    Science.gov (United States)

    Calvo-López, Antonio; Ymbern, Oriol; Puyol, Mar; Casalta, Joan Manel; Alonso-Chamarro, Julián

    2015-05-18

    The design, construction and evaluation of a versatile cyclic olefin copolymer (COC)-based continuous flow potentiometric microanalyzer to monitor the presence of ammonium ion in recycling water processes for future manned space missions is presented. The microsystem integrates microfluidics, a gas-diffusion module and a detection system in a single substrate. The gas-diffusion module was integrated by a hydrophobic polyvinylidene fluoride (PVDF) membrane. The potentiometric detection system is based on an all-solid state ammonium selective electrode and a screen-printed Ag/AgCl reference electrode. The analytical features provided by the analytical microsystem after the optimization process were a linear range from 0.15 to 500 mg L(-1) and a detection limit of 0.07 ± 0.01 mg L(-1). Nevertheless, the operational features can be easily adapted to other applications through the modification of the hydrodynamic variables of the microfluidic platform. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Second-order Data by Flow Injection Analysis with Spectrophotometric Diode-array Detection and Incorporated Gel-filtration Chromatographic Column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard

    1997-01-01

    A flow injection analysis (FIA) system furnished with a gel-filtration chromatographic column and with photodiode-array detection was used for the generation of second-order data. The system presented is a model system in which the analytes are blue dextran, potassium hexacyanoferrate(III) and he......A flow injection analysis (FIA) system furnished with a gel-filtration chromatographic column and with photodiode-array detection was used for the generation of second-order data. The system presented is a model system in which the analytes are blue dextran, potassium hexacyanoferrate...

  20. Automation of potentiometric titration with a personal computer using ...

    African Journals Online (AJOL)

    sampling was designed and tested for automation of potentiometric titrations with personal ... automation permits us to carry out new types of experiments, such as those requiring ... have proved to be very useful in routine tasks but not in research, due to their ... This is done by a simple delay sub-routine in data acquisition.

  1. Specification analysis of plutonium fuels : a potentiometric method for the determination of plutonium

    International Nuclear Information System (INIS)

    Vaidyanathan, S.; Natarajan, P.R.

    1977-01-01

    A potentiometric method for the routine determination of plutonium in the specification analysis of plutonium fuels is described. Plutonium is oxidized to Pu(VI) with AgO and Pu(VI) is reduced with Fe(II) after the destruction of excess AgO with sulphamic acid. The excess Fe(II) is titrated potentiometrically against K 2 Cr 2 O 7 , the titration being carried out by adding a concentrated titrant solution from a weight burette and a suitably diluted solution from another weight burette near the end. The overall relative standard deviation obtained in 326 analyses of a working standard solution by eight experimenters is 0.14 percent. (author)

  2. The effect of saturation on resin flow in injection pultrusion: a preliminary numerical study

    DEFF Research Database (Denmark)

    Spangenberg, Jon; Larsen, Martin; R. Rodríguez, Rosa

    . The implemented saturation and relative permeability curves are adopted from relationships presented in the literature. The results of the numerical model highlights the importance of accurately determining thesaturation curve when included in a numerical solver that is used to predict the resin flow in injection...

  3. Assessing preferential flow by simultaneously injecting nanoparticle and chemical tracers

    KAUST Repository

    Subramanian, S. K.; Li, Yan; Cathles, L. M.

    2013-01-01

    The exact manner in which preferential (e.g., much faster than average) flow occurs in the subsurface through small fractures or permeable connected pathways of other kinds is important to many processes but is difficult to determine, because most chemical tracers diffuse quickly enough from small flow channels that they appear to move more uniformly through the rock than they actually do. We show how preferential flow can be assessed by injecting 2 to 5 nm carbon particles (C-Dots) and an inert KBr chemical tracer at different flow rates into a permeable core channel that is surrounded by a less permeable matrix in laboratory apparatus of three different designs. When the KBr tracer has a long enough transit through the system to diffuse into the matrix, but the C-Dot tracer does not, the C-Dot tracer arrives first and the KBr tracer later, and the separation measures the degree of preferential flow. Tracer sequestration in the matrix can be estimated with a Peclet number, and this is useful for experiment design. A model is used to determine the best fitting core and matrix dispersion parameters and refine estimates of the core and matrix porosities. Almost the same parameter values explain all experiments. The methods demonstrated in the laboratory can be applied to field tests. If nanoparticles can be designed that do not stick while flowing through the subsurface, the methods presented here could be used to determine the degree of fracture control in natural environments, and this capability would have very wide ranging value and applicability.

  4. Potentiometric surfaces, summer 2013 and winter 2015, and select hydrographs for the Southern High Plains aquifer, Cannon Air Force Base, Curry County, New Mexico

    Science.gov (United States)

    Collison, Jake

    2016-04-07

    Cannon Air Force Base (Cannon AFB) is located in the High Plains physiographic region of east-central New Mexico, about 5 miles west of Clovis, New Mexico. The area surrounding Cannon AFB is primarily used for agriculture, including irrigated cropland and dairies. The Southern High Plains aquifer is the principal source of water for Cannon AFB, for the nearby town of Clovis, and for local agriculture and dairies. The Southern High Plains aquifer in the vicinity of Cannon AFB consists of three subsurface geological formations: the Chinle Formation of Triassic age, the Ogallala Formation of Tertiary age, and the Blackwater Draw Formation of Quaternary age. The Ogallala Formation is the main water-yielding formation of the Southern High Plains aquifer. Groundwater-supplied, center-pivot irrigation dominates pumping from the Southern High Plains aquifer in the area surrounding Cannon AFB, where the irrigation season typically extends from early March through October. The U.S. Geological Survey has been monitoring groundwater levels in the vicinity of Cannon AFB since 1954 and has developed general potentiometric-surface maps that show groundwater flow from northwest to southeast in the study area. While previous potentiometric-surface maps show the general direction of groundwater flow, a denser well network is needed to show details of groundwater flow at a local scale. Groundwater levels were measured in 93 wells during summer 2013 and 100 wells during winter 2015.The summer and winter potentiometric-surface maps display the presence of what is interpreted to be a groundwater trough trending from the northwest to the southeast through the study area. This groundwater trough may be the hydraulic expression of a Tertiary-age paleochannel. Groundwater north of the trough flows in a southerly direction into the trough, and groundwater south of the trough flows in an easterly direction into the trough.During the 18-month period between summer 2013 and winter 2015, changes

  5. Determination of pH by flow-injection analysis and by fiber-optrode analysis

    International Nuclear Information System (INIS)

    Pia, S.H.; Waltman, D.P.; Hillman, D.C.

    1988-07-01

    Two new procedures for measuring pH were developed. The first measures pH colorimetrically using a proprietary indicator-dye mixture in a flow injection analysis (FIA) procedure. The second measures pH using a fiber-optic chemical sensor (FOCS) specifically developed for pH determinations. The FOCS method measures pH by monitoring the fluorescence of a fluorescein derivative bonded to the distal end of a fiber-optic cable called an optrade. The FIA method currently has a precision and accuracy of about + or - 0.2 pH units and can measure 100 samples/hour. The FOCS method has a precision of + or - 0.05-0.20 pH units and an accuracy of + or - 0.1 to 0.6 pH units. About 10 to 60 samples can be analyzed. The characteristics of the FOCS Method will vary significantly with individual optrodes. The experimental results indicate that either flow-injection analysis or fiber optic chemical sensor analysis could form the basis for an alternative to electrometric measurement of pH in certain circumstances

  6. Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor.

    Science.gov (United States)

    Wisitsoraat, A; Sritongkham, P; Karuwan, C; Phokharatkul, D; Maturos, T; Tuantranont, A

    2010-12-15

    This work reports a new cholesterol detection scheme using functionalized carbon nanotube (CNT) electrode in a polydimethylsiloxane/glass based flow injection microfluidic chip. CNTs working, silver reference and platinum counter electrode layers were fabricated on the chip by sputtering and low temperature chemical vapor deposition methods. Cholesterol oxidase prepared in polyvinyl alcohol solution was immobilized on CNTs by in-channel flow technique. Cholesterol analysis based on flow injection chronoamperometric measurement was performed in 150-μm-wide and 150-μm-deep microchannels. Fast and sensitive real-time detection was achieved with high throughput of more than 60 samples per hour and small sample volume of 15 μl. The cholesterol sensor had a linear detection range between 50 and 400 mg/dl. In addition, low cross-sensitivities toward glucose, ascorbic acid, acetaminophen and uric acid were confirmed. The proposed system is promising for clinical diagnostics of cholesterol with high speed real-time detection capability, very low sample consumption, high sensitivity, low interference and good stability. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    International Nuclear Information System (INIS)

    Mesquita, Raquel B.R.; Ferreira, M. Teresa S.O.B.; Toth, Ildiko V.; Bordalo, Adriano A.; McKelvie, Ian D.; Rangel, Antonio O.S.S.

    2011-01-01

    Highlights: → Sequential injection determination of phosphate in estuarine and freshwaters. → Alternative spectrophotometric flow cells are compared. → Minimization of schlieren effect was assessed. → Proposed method can cope with wide salinity ranges. → Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 μM PO 4 3- ) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 μM) was achieved using both detection systems.

  8. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Raquel B.R. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); Ferreira, M. Teresa S.O.B. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Toth, Ildiko V. [REQUIMTE, Departamento de Quimica, Faculdade de Farmacia, Universidade de Porto, Rua Anibal Cunha, 164, 4050-047 Porto (Portugal); Bordalo, Adriano A. [Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); McKelvie, Ian D. [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Rangel, Antonio O.S.S., E-mail: aorangel@esb.ucp.pt [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2011-09-02

    Highlights: {yields} Sequential injection determination of phosphate in estuarine and freshwaters. {yields} Alternative spectrophotometric flow cells are compared. {yields} Minimization of schlieren effect was assessed. {yields} Proposed method can cope with wide salinity ranges. {yields} Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 {mu}M PO{sub 4}{sup 3-}) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 {mu}M) was achieved using both detection systems.

  9. Creating potentiometric surfaces from combined water well and oil well data in the midcontinent of the United States

    Science.gov (United States)

    Gianoutsos, Nicholas J.; Nelson, Philip H.

    2013-01-01

    For years, hydrologists have defined potentiometric surfaces using measured hydraulic-head values in water wells from aquifers. Down-dip, the oil and gas industry is also interested in the formation pressures of many of the same geologic formations for the purpose of hydrocarbon recovery. In oil and gas exploration, drillstem tests (DSTs) provide the formation pressure for a given depth interval in a well. These DST measurements can be used to calculate hydraulic-head values in deep hydrocarbon-bearing formations in areas where water wells do not exist. Unlike hydraulic-head measurements in water wells, which have a low number of problematic data points (outliers), only a small subset of the DST data measure true formation pressures. Using 3D imaging capabilities to view and clean the data, we have developed a process to estimate potentiometric surfaces from erratic DST data sets of hydrocarbon-bearing formations in the midcontinent of the U.S. The analysis indicates that the potentiometric surface is more readily defined through human interpretation of the chaotic DST data sets rather than through the application of filtering and geostatistical analysis. The data are viewed as a series of narrow, 400-mile-long swaths and a 2D viewer is used to select a subset of hydraulic-head values that represent the potentiometric surface. The user-selected subsets for each swath are then combined into one data set for each formation. These data are then joined with the hydraulic-head values from water wells to define the 3D potentiometric surfaces. The final product is an interactive, 3D digital display containing: (1) the subsurface structure of the formation, (2) the cluster of DST-derived hydraulic head values, (3) the user-selected subset of hydraulic-head values that define the potentiometric surface, (4) the hydraulic-head measurements from the corresponding shallow aquifer, (5) the resulting potentiometric surface encompassing both oil and gas and water wells, and (6

  10. Potentiometric Measurement of Transition Ranges and Titration Errors for Acid/Base Indicators

    Science.gov (United States)

    Flowers, Paul A.

    1997-07-01

    Sophomore analytical chemistry courses typically devote a substantial amount of lecture time to acid/base equilibrium theory, and usually include at least one laboratory project employing potentiometric titrations. In an effort to provide students a laboratory experience that more directly supports their classroom discussions on this important topic, an experiment involving potentiometric measurement of transition ranges and titration errors for common acid/base indicators has been developed. The pH and visually-assessed color of a millimolar strong acid/base system are monitored as a function of added titrant volume, and the resultant data plotted to permit determination of the indicator's transition range and associated titration error. Student response is typically quite positive, and the measured quantities correlate reasonably well to literature values.

  11. Potentiometric determination of free nitric-acid in trilaurylamine solutions containing plutonium nitrate

    International Nuclear Information System (INIS)

    Perez, J.J.; Saey, J.C.

    1965-01-01

    A potentiometric method of determination of the free nitric acid in trilaurylamine solutions containing plutonium or thorium nitrates is described. The potentiometric titration is carried out in a mixture of benzene and 1,2-dichloro ethane with a standard solution of trilaurylamine as the titrant. When thorium nitrate is present the metal complex is not dissociated then the titration has a single end-point. In the case of plutonium nitrate the partial dissociation of the plutonium complex corresponds to a second point. The experimental error in duplicate analyses of 50 samples is about 1 per cent for free acid concentrations in the range of 0,03 to 0,1 N and plutonium concentrations between 1 to 5 g/l. (authors) [fr

  12. Potentiometric assay for hydrogenocarbonate in natural waters

    OpenAIRE

    Milla González, Miguel

    2008-01-01

    Potentiometry is often used for the determination of hydrogenocarbonate in natural water samples. In this exercise, a volume V of the titrant HCl is required for the potentiometric analysis of the mentioned species in 50 mL of water sample. The titrant concentration is M molar. The user should calculate the concentration of hydrogenocarbonate and express it either in mg/L or in g/L of calcium carbonate by building up the corresponding stoichiometric expressions. All results entered in the sys...

  13. Indirect flow injection determination of N-acetyl-L-cysteine using cerium(IV) and ferroin

    International Nuclear Information System (INIS)

    Vieira, Heberth Juliano; Fatibello-Filho, Orlando

    2005-01-01

    An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen) 2 ] 2+ ) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen) 2 ] 3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10 -6 to 1.3x10 -4 mol L -1 . The detection limit was 5.0x10 -6 mol L -1 and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10 -5 mol L -1 N-acetyl-L-cysteine. (author)

  14. Cumulative Distributions and Flow Structure of Two-Passage Shear Coaxial Injector with Various Gas Injection Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Inchul; Kim, Dohun; Koo, Jaye [Korea Aerospace Univ., Goyang (Korea, Republic of)

    2013-07-15

    To verify the effect of inner- and outer-stage gas jets, a shear coaxial injector was designed to analyze the axial velocity profile and breakup phenomenon with an increase in the measurement distance. When the measurement position was increased to Z/d=100, the axial flow showed a fully developed shape due to the momentum transfer, aerodynamic drag effect, and viscous mixing. An inner gas injection, which induces a higher momentum flux ratio near the nozzle, produces the greater shear force on atomization than an outer gas injection. Inner- and Outer-stage gas injection do not affect the mixing between the inner and outer gas flow below Z/d=5. The experiment results showed that the main effect of liquid jet breakup was governed by the gas jet of an inner stage. As the nozzle exit of the outer-stage was located far from the liquid column, shear force and turbulence breaking up of the liquid jets do not fully affect the liquid column. In the case of an inner-stage gas injection momentum flux ratio within 0.84, with the increase in the outer gas momentum flux ratio, the Smd decreases. However, at an inner-stage gas jet momentum flux ratio over 1.38, the Smd shows the similar distribution.

  15. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad

    2017-03-28

    Partially Premixed Combustion (PPC) is a promising combustion concept ,based on judicious tuning of the charge stratification, to meet the increasing demands of emission legislation and to improve fuel efficiency. Longer ignition delays of PPC in comparison with conventional diesel combustion provide better fuel/air mixture which decreases soot and NO emissions. Moreover, a proper injection timing and strategy for PPC can improve the combustion stability as a result of a higher level of fuel stratification in comparison with the Homogeneous Charge Compression Ignition (HCCI) concept. Injection timing is the major parameter with which to affect the level of fuel and combustion stratification and to control the combustion phasing and the heat release behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow characteristics, including the flow fields, mean velocity and cycle-resolved turbulence, inside the piston bowl as well as the squish region with a temporal resolution of 1 crank angle degree at 800 rpm. Two injectors, having 5 and 7 holes, were compared to see their effects on fluid flow and heat release behavior for different injection timings. Reactive and non-reactive measurements were performed to distinguish injection-driven and combustion-driven turbulence. Formation of vortices and higher turbulence levels enhance the air/fuel interaction, changing the level of fuel stratification and combustion duration. Results demonstrate clearly how turbulence level correlates with heat release behavior, and provide a quantitative dataset for validation of numerical simulations.

  16. Potentiometric surfaces of the intermediate aquifer system, west-central Florida, May, 1993

    Science.gov (United States)

    Mularoni, R.A.

    1994-01-01

    The intermediate aquifer system underlies a 5000-sq-mi area including De Soto, Sarasota, Hardee, Manatee, and parts of Charlotte, Hillsborough, Highlands, and Polk Counties, Florida. It is overlain by the surf@cial aquifer system and underlain by the Floridan aquifer system. The potentiometric surface of the intermediate aquifer system was mapped by determining the altitude of water levels in a network of wells and represented on a map by contours that connect points of equal altitude. This map represents water-level conditions near the end of the spring dry season when ground- water withdrawals for agricultural use were high. The cumulative rainfall for the study area was 4.84 inches above normal for the period from June 1992 to May 1993. Hydrographs for selected wells indicated that the annual and seasonal fluctuations of the water levels were generally large (greater than 15 feet) in the central interior region where water demand for irrigation is high during the fall and spring. Seasonal fluctuations were smaller in the northern recharge area where water use is predominantly for public supply. Water levels measured in May 1993 for the composite intermediate aquifer potentiometric surface were lower than those measured in May or September 1992. A cone of depression exists in the potentiometric surface for the composite aquifer system at Warm Mineral Springs, which is a natural discharge point from this system.

  17. Relationship between potentiometric measurements, sensorial analysis, and some substances responsible for aroma degradation of white wines.

    Science.gov (United States)

    Silva Ferreira, A C; Oliveira, Carla; Hogg, T; Guedes de Pinho, P

    2003-07-30

    Oxidative degradation of white wines can be described sensorially as developing from a loss at positive aroma characteristics, through the development of negative aromas to a linel stage of chromatic alterations. This work attempts to relate the oxidation "status" evaluate by potentiometric titrations, with sensorial degradation and the levels of substances responsible for "off-flavors", such as methional and phenylacetaldehyde. The potentiometric titration employed measures the most powerful antioxidants of white wines (e.g., those which more rapidly consume oxygen). Considering that aromatic precedes chromatic degradation, resistance to oxidation (ROX) constitutes a useful indicator of resistance to oxidation. Sensorial degradation (ID), potentiometric measures, and volatiles were determined both in samples submitted to a "forced aging" protocol and normal aged white wines. High correlation values were observed between ROX and the ID, in both sets (r > 0.87). ID is better explained by ROX values than by the indicated wine age or by the "degree of browning" (Abs = 420 nm). It was also observed that in samples with ROX values higher than 10, the concentration of methional and phenylacetaldehyde were above their respective odor threshold. Finally, it was observed that there is a relationship between oxygen consumption and the respective ROX. Although these results seem very promising, they needed to be further complemented in order to estimate the shelf life of a white wine using potentiometric titrations.

  18. Performance Analysis of Multi Stage Safety Injection Tank

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo

    2015-01-01

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  19. Performance Analysis of Multi Stage Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  20. Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, September 2006

    Science.gov (United States)

    Ortiz, A.G.

    2007-01-01

    The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2006. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 46.06 inches for west-central Florida (from October 2005 through September 2006) was 6.91 inches below the historical cumulative average of 52.97 inches (Southwest Florida Water Management District, 2006). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each

  1. Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, September 2007

    Science.gov (United States)

    Ortiz, A.G.

    2008-01-01

    The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2007. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 39.50 inches for west-central Florida (from October 2006 through September 2007) was 13.42 inches below the historical cumulative average of 52.92 inches (Southwest Florida Water Management District, 2007). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each

  2. Potentiometric surface of the Upper Floridan aquifer, west-central Florida, September 2005

    Science.gov (United States)

    Ortiz, A.G.

    2006-01-01

    The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public-supply, domestic use, irrigation, and brackish-water desalination in coastal communities (Southwest Florida Water Management District, 2000).This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2005. The potentiometric surface is an imaginary surface, connecting points of equal altitude to which water will rise in tightly cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 55.19 inches for west-central Florida (from October 2004 through September 2005) was 2.00 inches above the historical cumulative average of 53.19 inches (Southwest Florida Water Management District, 2005). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District.This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year

  3. Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, May 2007

    Science.gov (United States)

    Ortiz, A.G.

    2008-01-01

    The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2007. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when ground-water levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 41.21 inches for west-central Florida (from June 2006 through May 2007) was 11.63 inches below the historical cumulative average of 52.84 inches (Southwest Florida Water Management District, 2007). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the

  4. Comparison between amperometric and true potentiometric end-point detection in the determination of water by the Karl Fischer method.

    Science.gov (United States)

    Cedergren, A

    1974-06-01

    A rapid and sensitive method using true potentiometric end-point detection has been developed and compared with the conventional amperometric method for Karl Fischer determination of water. The effect of the sulphur dioxide concentration on the shape of the titration curve is shown. By using kinetic data it was possible to calculate the course of titrations and make comparisons with those found experimentally. The results prove that the main reaction is the slow step, both in the amperometric and the potentiometric method. Results obtained in the standardization of the Karl Fischer reagent showed that the potentiometric method, including titration to a preselected potential, gave a standard deviation of 0.001(1) mg of water per ml, the amperometric method using extrapolation 0.002(4) mg of water per ml and the amperometric titration to a pre-selected diffusion current 0.004(7) mg of water per ml. Theories and results dealing with dilution effects are presented. The time of analysis was 1-1.5 min for the potentiometric and 4-5 min for the amperometric method using extrapolation.

  5. An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach.

    Science.gov (United States)

    Kozak, Joanna; Wójtowicz, Marzena; Gawenda, Nadzieja; Kościelniak, Paweł

    2011-06-15

    An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. An efficient ab initio DFT and PCM assessment of the potentiometric selectivity of a salophen type Schiff base.

    Science.gov (United States)

    Demir, Serkan; Yilmaz, Hakan; Dilimulati, Maowulidan; Andaç, Müberra

    2014-06-01

    As a neutral carrier component for the preparation of a potentiometric membrane sensor, the affinity and selectivity of the salophen type Schiff base ligand obtained by 1:2 condensation of 2.3-diaminopyridine with salicylaldehyde toward a series of common cations has been fully examined by DFT/B3LYP and integral equation formalism polarizable continum model (IEF-PCM or only given with PCM as default input in the computations) in combination with the experimental data. Both the potentiometric measurements and DFT calculations have exhibited that the ionophore shows appreciable selectivity for Cu(2+) ion over other cations. Four different approaches where the last three are the modified version of each other have been evaluated and compared with potentiometric data. Based upon the results of comparison among the approaches suggested to verify the selective behavior of ionophore toward Cu(2+), PCM implemented approach having a whole computational groundwork has given well-matched results with the observed data and with the method augmented with experimental hydration energies. The foremost interferences were detected by determining potentiometric selectivity coefficients for each metal ion relative to Cu(2+) and compared to the results obtained by the DFT calculations.

  7. Accurate potentiometric determination of lipid membrane-water partition coefficients and apparent dissociation constants of ionizable drugs: electrostatic corrections.

    Science.gov (United States)

    Elsayed, Mustafa M A; Vierl, Ulrich; Cevc, Gregor

    2009-06-01

    Potentiometric lipid membrane-water partition coefficient studies neglect electrostatic interactions to date; this leads to incorrect results. We herein show how to account properly for such interactions in potentiometric data analysis. We conducted potentiometric titration experiments to determine lipid membrane-water partition coefficients of four illustrative drugs, bupivacaine, diclofenac, ketoprofen and terbinafine. We then analyzed the results conventionally and with an improved analytical approach that considers Coulombic electrostatic interactions. The new analytical approach delivers robust partition coefficient values. In contrast, the conventional data analysis yields apparent partition coefficients of the ionized drug forms that depend on experimental conditions (mainly the lipid-drug ratio and the bulk ionic strength). This is due to changing electrostatic effects originating either from bound drug and/or lipid charges. A membrane comprising 10 mol-% mono-charged molecules in a 150 mM (monovalent) electrolyte solution yields results that differ by a factor of 4 from uncharged membranes results. Allowance for the Coulombic electrostatic interactions is a prerequisite for accurate and reliable determination of lipid membrane-water partition coefficients of ionizable drugs from potentiometric titration data. The same conclusion applies to all analytical methods involving drug binding to a surface.

  8. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  9. Flow injection on-line preconcentration of low levels of Cr(VI) with detection by ETAAS

    DEFF Research Database (Denmark)

    Som-aum, Waraporn; Liawruangrath, Saisunee; Hansen, Elo Harald

    2002-01-01

    A flow injection (FI) on-line sorption preconcentration procedure utilizing a packed column reactor and combined with electrothermal atomic absorption spectrometry (ETAAS) is proposed for the determination of low levels of Cr(VI) in water samples. Polytetrafluoroethylene (PTFE) beads packed in a ...

  10. Determination of uranium (IV) in cloride solutions of enrichment columns by spectrometry with flow injection

    International Nuclear Information System (INIS)

    Bastos, M.B.R.

    1988-01-01

    The utilization of Flow Injection Analysis for the U (IV) spectrophotometric determination in chloride solutions is described. The method has been shown reproducible in the range of concentrations and conditions employed with a standard deviation of about 0,3. (C.G.C.) [pt

  11. Molecular dynamics simulation of potentiometric sensor response: the effect of biomolecules, surface morphology and surface charge.

    Science.gov (United States)

    Lowe, B M; Skylaris, C-K; Green, N G; Shibuta, Y; Sakata, T

    2018-05-10

    The silica-water interface is critical to many modern technologies in chemical engineering and biosensing. One technology used commonly in biosensors, the potentiometric sensor, operates by measuring the changes in electric potential due to changes in the interfacial electric field. Predictive modelling of this response caused by surface binding of biomolecules remains highly challenging. In this work, through the most extensive molecular dynamics simulation of the silica-water interfacial potential and electric field to date, we report a novel prediction and explanation of the effects of nano-morphology on sensor response. Amorphous silica demonstrated a larger potentiometric response than an equivalent crystalline silica model due to increased sodium adsorption, in agreement with experiments showing improved sensor response with nano-texturing. We provide proof-of-concept that molecular dynamics can be used as a complementary tool for potentiometric biosensor response prediction. Effects that are conventionally neglected, such as surface morphology, water polarisation, biomolecule dynamics and finite-size effects, are explicitly modelled.

  12. Potentiometric and ab initio studies of acid-base interactions of substituted 4-halo(Cl, Br)pyridine N-oxide systems

    International Nuclear Information System (INIS)

    Gurzynski, Lukasz; Puszko, Aniela; Makowski, Mariusz; Makowska, Joanna; Chmurzynski, Lech

    2006-01-01

    By using the potentiometric method, acidity constants have been determined in systems of tri- and tetra-substituted pyridine N-oxides. The potentiometric measurements in systems of four 4-chloropyridine N-oxide derivatives containing the chlorine atom at position 4 to the NO 2 group and four bromine counterparts were carried out in polar non-aqueous solvents, viz. amphiprotic methanol (MeOH) and aprotic protophilic dimethyl sulfoxide (DMSO). It was found that in all the systems studied the pK a values were readily determinable (as indicated by small standard deviations) in MeOH, whereas in DMSO large standard deviations were obtained making the pK a values either hardly determinable or indeterminable from potentiometric measurements. Furthermore, it was demonstrated that the acidity constants of protonated N-oxides studied in MeOH changed according to the sequence of their acidity constants in water. It was also found that in the polar solvents studied, i.e. in the amphiprotic methanol and the highly basic aprotic dimethyl sulfoxide, the cationic homo-conjugation equlibrium constants could not be determined using potentiometric method. Also, by using ab initio methods at the RHF and MP2 levels and the PCM model, utilizing the Gaussian 6-31++G** basis set, energies and Gibbs free energies of the protonation reactions of the N-oxides have been determined. The energy parameters have been compared with acidity constants of the protonated N-oxides determined by potentiometric titration in methanol to establish a correlation between these approaches

  13. Effects of Injection Timing on Fluid Flow Characteristics of Partially Premixed Combustion Based on High-Speed Particle Image Velocimetry

    KAUST Repository

    Izadi Najafabadi, Mohammad; Tanov, Slavey; Wang, Hua; Somers, Bart; Johansson, Bengt; Dam, Nico

    2017-01-01

    behavior. The scope of the present study is to investigate the fluid flow characteristics of PPC at different injection timings. To this end, high-speed Particle Image Velocimetry (PIV) is implemented in a light-duty optical engine to measure fluid flow

  14. Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.

    Science.gov (United States)

    Bell-Vlasov, Andrea K; Zajda, Joanna; Eldourghamy, Ayman; Malinowska, Elzbieta; Meyerhoff, Mark E

    2014-04-15

    A method for the detection of polyions using fully reversible polyion selective polymeric membrane type pulstrodes as detectors in a flow-injection analysis (FIA) system is examined. The detection electrode consists of a plasticized polymeric membrane doped with 10 wt % of tridodecylmethylammonium-dinonylnaphthalene sulfonate (TDMA/DNNS) ion-exchanger salt. The pulse sequence used involves a short (1 s) galvanostatic pulse, an open-circuit pulse (0.5 s) during which the EMF of the cell is measured, and a longer (15 s) potentiostatic pulse to return the membrane to its original chemical composition. It is shown that total pulse sequence times can be optimized to yield reproducible real-time detection of injected samples of protamine and heparin at up to 20 samples/h. Further, it is shown that the same membrane detector can be employed for FIA detection of both polycations at levels ≥10 μg/mL and polyanions at levels of ≥40 μg/mL by changing the direction of the galvanostatic pulse. The methodology described may also be applicable in the detection of polyionic species at low levels in other flowing configurations, such as in liquid chromatography and capillary electrophoresis.

  15. Improved upper bounds on energy dissipation rates in plane Couette flow with boundary injection and suction

    Science.gov (United States)

    Lee, Harry; Wen, Baole; Doering, Charles

    2017-11-01

    The rate of viscous energy dissipation ɛ in incompressible Newtonian planar Couette flow (a horizontal shear layer) imposed with uniform boundary injection and suction is studied numerically. Specifically, fluid is steadily injected through the top plate with a constant rate at a constant angle of injection, and the same amount of fluid is sucked out vertically through the bottom plate at the same rate. This set-up leads to two control parameters, namely the angle of injection, θ, and the Reynolds number of the horizontal shear flow, Re . We numerically implement the `background field' variational problem formulated by Constantin and Doering with a one-dimensional unidirectional background field ϕ(z) , where z aligns with the distance between the plates. Computation is carried out at various levels of Re with θ = 0 , 0 .1° ,1° and 2°, respectively. The computed upper bounds on ɛ scale like Re0 as Re > 20 , 000 for each fixed θ, this agrees with Kolmogorov's hypothesis on isotropic turbulence. The outcome provides new upper bounds to ɛ among any solution to the underlying Navier-Stokes equations, and they are sharper than the analytical bounds presented in Doering et al. (2000). This research was partially supported by the NSF Award DMS-1515161, and the University of Michigan's Rackham Graduate Student Research Grant.

  16. Non-euclidean simplex optimization. [Application to potentiometric titration of Pu

    Energy Technology Data Exchange (ETDEWEB)

    Silver, G.L.

    1977-08-15

    Geometric optimization techniques useful for studying chemical equilibrium traditionally rely upon principles of euclidean geometry, but such algorithms may also be based upon principles of a non-euclidean geometry. The sequential simplex method is adapted to the hyperbolic plane, and application of optimization to problems such as the potentiometric titration of plutonium is suggested.

  17. Flow-injection fluorimetric determination of menadione using on-line photo-reduction in micellar media

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2004-07-01

    A very sensitive fluorimetric method for the determination of menadione using a flow injection system is proposed. The method is based on the on-line reduction of menadione in dodecylsulphate micelles upon irradiation with UV light. The strong fluorescence of the reduced menadione in micellar medium is measured at 410 nm with excitation at 340 nm. The method shows a linear range between 2.42 and 245 ng ml{sup -1} and a limit of detection of 0.18 ng ml{sup -1}. The sample throughput was 90 injections per hour. The applicability of the assay was demonstrated by analysing this vitamin in commercial pharmaceutical preparations.

  18. Flow-injection fluorimetric determination of menadione using on-line photo-reduction in micellar media

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2004-01-01

    A very sensitive fluorimetric method for the determination of menadione using a flow injection system is proposed. The method is based on the on-line reduction of menadione in dodecylsulphate micelles upon irradiation with UV light. The strong fluorescence of the reduced menadione in micellar medium is measured at 410 nm with excitation at 340 nm. The method shows a linear range between 2.42 and 245 ng ml -1 and a limit of detection of 0.18 ng ml -1 . The sample throughput was 90 injections per hour. The applicability of the assay was demonstrated by analysing this vitamin in commercial pharmaceutical preparations

  19. Channel flow induced by wall injection of fluid and particles; Ecoulement induit par injection parietale de fluide et de particules dans un conduit

    Energy Technology Data Exchange (ETDEWEB)

    Feraille, Th.; Casalis, G. [Aerodynamics and Energetics Modeling Dept., 31 - Toulouse (France)

    2003-12-01

    The Taylor flow is the laminar single phase flow induced by gas injection through porous walls, and is assumed to represent the flow inside solid propellant motors. Such a flow is intrinsically unstable, and the generated instabilities are probably responsible for the thrust oscillations observed in the aforesaid motors. However particles are embedded in the propellants usually used, and are released in the fluid by the lateral walls during the combustion, so that there are two heterogeneous phases in the flow. The purpose of this paper is to study the influence of these particles on stability by comparison with stability results from the single phase studies, in a plane two-dimensional configuration. The particles are supposed to be chemically inert and of a uniform size. In order to carry out a linear stability study for this flow modified by the presence of particles, the mean particle velocity field is first determined, assuming that only the gas exerts forces on the particles. This field is sought in a self similar form, which imposes a limit on the size of the particles. However, the particle mass concentration cannot be obtained in a self similar form, but can only, be described by a partial differential equation. The mean flow characteristics being determined, the spectrum of the discretized linear stability operator shows first that particle addition does not trigger any new 'dangerous' modes compared with the single phase flow case. It also shows that the most amplified mode in the case of the single phase flow remains the most amplified mode in the case of the two phase flow. Moreover, the addition of particles acts continuously upon stability results, behaving linearly with respect to the particle mass concentration when the latter is small. The linear correction to the monophasic mode, as well as the evolution of the modes with weak values of the particle mass concentration at the wall, are shown to be proportional to the ejection velocity of

  20. Determination of gallic acid with rhodanine by reverse flow injection analysis using simplex optimization.

    Science.gov (United States)

    Phakthong, Wilaiwan; Liawruangrath, Boonsom; Liawruangrath, Saisunee

    2014-12-01

    A reversed flow injection (rFI) system was designed and constructed for gallic acid determination. Gallic acid was determined based on the formation of chromogen between gallic acid and rhodanine, resulting in a colored product with a λmax at 520 nm. The optimum conditions for determining gallic acid were also investigated. Optimizations of the experimental conditions were carried out based on the so-call univariate method. The conditions obtained were 0.6% (w/v) rhodanine, 70% (v/v) ethanol, 0.9 mol L(-1) NaOH, 2.0 mL min(-1) flow rate, 75 μL injection loop and 600 cm mixing tubing length, respectively. Comparative optimizations of the experimental conditions were also carried out by multivariate or simplex optimization method. The conditions obtained were 1.2% (w/v) rhodanine, 70% (v/v) ethanol, 1.2 mol L(-1) NaOH, flow rate 2.5 mL min(-1), 75 μL injection loop and 600 cm mixing tubing length, respectively. It was found that the optimum conditions obtained by the former optimization method were mostly similar to those obtained by the latter method. The linear relationship between peak height and the concentration of gallic acid was obtained over the range of 0.1-35.0 mg L(-1) with the detection limit 0.081 mg L(-1). The relative standard deviations were found to be in the ranges 0.46-1.96% for 1, 10, 30 mg L(-1) of gallic acid (n=11). The method has the advantages of simplicity extremely high selectivity and high precision. The proposed method was successfully applied to the determination of gallic acid in longan samples without interferent effects from other common phenolic compounds that might be present in the longan samples collected in northern Thailand. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Solid-state potentiometric biosensors for pH quantification in biological samples

    NARCIS (Netherlands)

    Ivan, M.G.; Wiegersma, S.; Sweelssen, J.; Saalmink, M.; Boersma, A.

    2011-01-01

    This paper reports on manufacturing and characterization of an all-solid-state potentiometric sensor aimed at monitoring pH in dialysate or blood plasma for patients who undergo dialysis. The sensing polymer-based membrane, coated on top of the Au working electrodes, contains a polymer matrix -

  2. Effects of GC temperature and carrier gas flow rate on on-line oxygen isotope measurement as studied by on-column CO injection.

    Science.gov (United States)

    Chen, Zhi-Gang; Yin, Xi-Jie; Zhou, Youping

    2015-08-01

    Although deemed important to δ 18 O measurement by on-line high-temperature conversion techniques, how the GC conditions affect δ 18 O measurement is rarely examined adequately. We therefore directly injected different volumes of CO or CO-N 2 mix onto the GC column by a six-port valve and examined the CO yield, CO peak shape, CO-N 2 separation, and δ 18 O value under different GC temperatures and carrier gas flow rates. The results show the CO peak area decreases when the carrier gas flow rate increases. The GC temperature has no effect on peak area. The peak width increases with the increase of CO injection volume but decreases with the increase of GC temperature and carrier gas flow rate. The peak intensity increases with the increase of GC temperature and CO injection volume but decreases with the increase of carrier gas flow rate. The peak separation time between N 2 and CO decreases with an increase of GC temperature and carrier gas flow rate. δ 18 O value decreases with the increase of CO injection volume (when half m/z 28 intensity is rate. On average, the δ 18 O value of the injected CO is about 1‰ higher than that of identical reference CO. The δ 18 O distribution pattern of the injected CO is probably a combined result of ion source nonlinearity and preferential loss of C 16 O or oxygen isotopic exchange between zeolite and CO. For practical application, a lower carrier gas flow rate is therefore recommended as it has the combined advantages of higher CO yield, better N 2 -CO separation, lower He consumption, and insignificant effect on δ 18 O value, while a higher-than-60 °C GC temperature and a larger-than-100 µl CO volume is also recommended. When no N 2 peak is expected, a higher GC temperature is recommended, and vice versa. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Heat and mass transfer in the stratified flow with ECCS injection

    International Nuclear Information System (INIS)

    Strubelj, L.; Tiselj, I.

    2007-01-01

    One of the most important problems in the light-water nuclear thermal-hydraulics is behaviour of the cold emergency core cooling water injected from the top or from the bottom into the horizontal section of the cold leg near the reactor vessel during the loss of coolant accident. The stratified flows appear where cold water is injected in partially or fully uncovered horizontal cold leg. The hot steam condenses on cold water surface what is also called direct contact condensation. Direct contact condensation and condensation induced water-hammer in a horizontal pipe were experimentally investigated at PMK-2 test facility of the Hungarian Atomic Energy Research Institute KFKI. The cold water is injected through small pipe into lower horizontal part of the section, and then water fills the vertical pipeline and floods the horizontal test section of the pipeline of the PMK-2 integral test facility. As liquid water floods the horizontal part of the pipeline, the counter current horizontally stratified flow is being observed. During the flooding of the pipeline, the steam-liquid interface area increases and therefore the steam condensation rate and the steam velocity also increase and can lead to bubble entrapment. Water level at one cross-section and four local void fraction and temperature at the top of horizontal test pipeline was measured and compared with simulation. Condensed steam increases the water temperature that is why the local temperature measurements are the most important information, from which condensation rate can be estimated, since mass of condensed steam was not measured. Numerical simulation of the experiment with thermal phase change is presented. Surface renewal concept with small eddies is used for calculation of condensation heat transfer coefficient. Two simulations were performed: simulation of whole experimental domain (lower horizontal, vertical and test horizontal pipeline) and simplified simulation of only upper horizontal test section

  4. Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study.

    Science.gov (United States)

    Gabbay, I E; Bahar, I; Nahum, Y; Livny, E

    2017-08-01

    Descemet's membrane endothelial keratoplasty (DMEK) involves removal of the recipient's Descemet membrane (DM) prior to transplanting the donor's DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host's DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS. We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC. Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p air in the AC contributes to better visualization and an efficient surgery.

  5. Spectrophotometric determination of uranium and thorium with arsenazo III in the flow injection system

    International Nuclear Information System (INIS)

    Andrade, M. das G.M. de.

    1986-12-01

    A simple system for flow injection analysis (FIA) with double confluence was built using a filter photocolorimeter, an analogic potentiometer, 'plexiglass' flow cuvettes, polyethylene colls and tubes, 'plexiglass' commuter and peristaltic pump to introduce solutions and gravity as flow source. The system was dimensioned and studied using only Arsenazo III solutions. Spectrophotometric methods for uranium and thorium using Arsenazo III were studied using a scanning spectrophotometer and after chosing adequate red filter, adapted to photocolorimetry using flow cuvettes and FIA. Synthetic samples, phosphate rock, and process samples from uranium recovery of dolomites were analysed. Rocks of Morro do Ferro (MG, Brazil), Caldasite (Baddeleyte + Zirconite), Zirconite, Monazite from a program for certification and certified rocks (Dunite DC-1, CANMET) were analysed without chemical separation of Th (IV) and with ion exchange separation in semi-micro columns of cation exchange resin (Dowex 50). (Author) [pt

  6. Reagent-free determination of amikacin content in amikacin sulfate injections by FTIR derivative spectroscopy in a continuous flow system

    Directory of Open Access Journals (Sweden)

    José F. Ovalles

    2014-04-01

    Full Text Available The quantitative estimation of amikacin (AMK in AMK sulfate injection samples is reported using FTIR-derivative spectrometric method in a continuous flow system. Fourier transform of mid-IR spectra were recorded without any sample pretreatment. A good linear calibration (r>0.999, %RSD<2.0 in the range of 7.7–77.0 mg/mL was found. The results showed a good correlation with the manufacturer's and overall they all fell within acceptable limits of most pharmacopoeial monographs on AMK sulfate. Keywords: Amikacin, FTIR derivative spectrometry, Continuous flow system, Pharmaceutical preparation, Injection, Sulfate

  7. Stripping potentiometric analysis: application to determination of metallic cations in presence of uranium

    International Nuclear Information System (INIS)

    Pereira-Ramos, J.P.; Chivot, J.; Sarantopoulos, F.; Godard, R.

    1984-01-01

    Potentiometric stripping analysis consists of a potentiostatic deposition step of trace elements and a subsequent stripping step. The trace metals are simultaneously reduced at a rotating electrode, the working electrode being a mercury film coated glassy carbon electrode; the amalgamated metals are then re-oxidized with an oxidizing agent. The analytical signal of this method is the time required for complete re-oxidation. Influence of different parameters on the analytical signal is studied by using mercury (II) ions as oxidizing agent in 5.10 -4 M H 2 SO 4 aqueous solution. Here, we point out the main characteristics of the potentiometric stripping analysis under the same experimental conditions. The reproductibility ranges are comprised between 0.5% to 1.5% and the detection limit for cadmium (II) is estimated to be 2.10 -10 M with a plating time of 300 seconds. Small quantities, as 10 -7 M Cd 2+ , Pb 2+ and Zn 2+ are simultaneously determined in presence of U (VI) ions (UO 2 2+ ) with an accuracy of 0.5% for Cd 2+ and Zn 2+ , and 4.5% for Pb 2+ . Compared to well-known electrochemical techniques, potentiometric stripping analysis appears to be a performing method for trace analysis in a wide range of media: this method permits the analysis of elements in presence of species more concentrated and being able to oxidize the trace elements [fr

  8. A hydraulic test device for free-flowing artesian boreholes with a ...

    African Journals Online (AJOL)

    Accurate parameter estimation for aquifers is very challenging, particularly for artesian aquifers in which the potentiometric surface is above ground level. A common approach to parameter estimation for artesian aquifers is to make use of free-flowing and recovery tests. However, such aquifer tests on artesian boreholes are ...

  9. Determination of titanium and vanadium in aqueous solutions by potentiometric titration

    International Nuclear Information System (INIS)

    Sibirkin, A.A.; Elliev, Yu.E.

    1996-01-01

    Possibility of titanium and vanadium determination at their combined presence by bichromatometric chromometric titration with potentiometric indication of end point is shown. The technique is developed which allows to determine titanium and vanadium with relative standard derivation ±2% in amounts not less than 50 and 100 mg respectively

  10. A novel stopped flow injection-amperometric procedure for the determination of chlorate.

    Science.gov (United States)

    Tue-Ngeun, Orawan; Jakmunee, Jaroon; Grudpan, Kate

    2005-12-15

    A novel stopped flow injection-amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200mV versus Ag/AgCl electrode is employed. In order to increase sensitivity without using of too high acid concentration, promoting of the reaction by increasing reaction time and temperature can be carried out. This can be done without increase of dispersion of the product zone by stopping the flow while the injected zone is being in a mixing coil which is immersed in a water bath of 55+/-0.5 degrees C. In a closed system of FIA, a side reaction of oxygen with iodide is also minimized. Under a set of conditions, linear calibration graphs were in the ranges of 1.2x10(-6)-6.0x10(-5)moll(-1)and 6.0x10(-5)-6.0x10(-4)moll(-1). A sample throughput of 25h(-1) was accomplished. Relative standard deviation was 2% (n=21, 1.2x10(-4)moll(-1) chlorate). The proposed sFI-Amp procedure was successfully applied to the determination of chlorate in soil samples from longan plantation area.

  11. Cavitating flow control through continuous tangential mass injection on a 2D hydrofoil at a small attack angle

    Directory of Open Access Journals (Sweden)

    Timoshevskiy Mikhail V.

    2016-01-01

    Full Text Available We studied cavitating flow over the suction side of a symmetric 2D foil – a scaled-down model of high-pressure hydroturbine guide vanes (GV – in different cavitation regimes at the attack angle of 3°. High-speed imaging was used to analyze spatial patterns and time dynamics of the gas-vapour cavities. A hydroacoustic pressure transducer was employed to register time-spectra of pressure fluctuations nearby the hydrofoil. A PIV technique was applied to measure the velocity fields and its fluctuations. The active flow control was implemented by means of a continuous liquid supply with different flow rates through a slot channel located in the GV surface. It was found that the active mass injection does not influence the primary flow upstream of the slot channel position. For the cavitation-free and cavitation inception cases, the injection was shown to make the turbulent wake past the GV section more intense. However, at the developed cavitation regimes the active flow management made it possible to reduce substantially the amplitude or even totally suppress the periodic cavity length oscillations and pressure pulsations associated with them.

  12. Potentiometric and ab initio studies of acid-base interactions of substituted 4-halo(Cl, Br)pyridine N-oxide systems

    Energy Technology Data Exchange (ETDEWEB)

    Gurzynski, Lukasz [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland); Puszko, Aniela [Department of Organic Chemistry, School of Economics, Wroclaw (Poland); Makowski, Mariusz [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland); Makowska, Joanna [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland); Chmurzynski, Lech [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland)]. E-mail: lech@chem.univ.gda.pl

    2006-12-15

    By using the potentiometric method, acidity constants have been determined in systems of tri- and tetra-substituted pyridine N-oxides. The potentiometric measurements in systems of four 4-chloropyridine N-oxide derivatives containing the chlorine atom at position 4 to the NO{sub 2} group and four bromine counterparts were carried out in polar non-aqueous solvents, viz. amphiprotic methanol (MeOH) and aprotic protophilic dimethyl sulfoxide (DMSO). It was found that in all the systems studied the pK {sub a} values were readily determinable (as indicated by small standard deviations) in MeOH, whereas in DMSO large standard deviations were obtained making the pK {sub a} values either hardly determinable or indeterminable from potentiometric measurements. Furthermore, it was demonstrated that the acidity constants of protonated N-oxides studied in MeOH changed according to the sequence of their acidity constants in water. It was also found that in the polar solvents studied, i.e. in the amphiprotic methanol and the highly basic aprotic dimethyl sulfoxide, the cationic homo-conjugation equlibrium constants could not be determined using potentiometric method. Also, by using ab initio methods at the RHF and MP2 levels and the PCM model, utilizing the Gaussian 6-31++G** basis set, energies and Gibbs free energies of the protonation reactions of the N-oxides have been determined. The energy parameters have been compared with acidity constants of the protonated N-oxides determined by potentiometric titration in methanol to establish a correlation between these approaches.

  13. Numerical Simulation of Magnetic Nanoparticles Injection into Two–phase Flow in a Porous Medium

    KAUST Repository

    El-Amin, Mohamed

    2017-06-09

    In this paper, the problem of magnetic nanoparticles injection into a water–oil two–phase flow under an external permanent magnetic field is investigated. The mathematical model of the problem under consideration has been developed. We treat the water-nanoparticles suspension as a miscible mixture while it is immiscible with the oil phase. The magnetized phase pressure includes an additional pressure term with the conventional thermodynamic pressure. The countercurrent imbibition flow problem is taken as an example. Physical variables including water–nanoparticles suspension saturation, nanoparticles concentration, and pore wall/throat deposited nanoparticles are investigated under the influence of the magnetic field.

  14. Effect of gas field production and CO2 injection on brine flow and salt precipitation

    NARCIS (Netherlands)

    Loeve, D.; Tambach, T.J.; Hofstee, C.; Plug, W.J.; Maas, J.

    2012-01-01

    This paper reports modeling of gas field produc-tion and CO2 injection from a theoretical reser-voir based on characteristics of the P18 gas field in the Dutch offshore, which consists of four geological deposits with different petrophysical properties. We especially focus on the brine flow during

  15. Reverse radiometric flow injection analysis (RFIA) of radioactive waste-waters with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    A new application of reverse radiometric flow injection analysis is described. RFIA was used for the analysis of radioactive wastewaters. ASIA (Ismatec) analyzer with NaI(Tl) scintillation detector was used in the study of analysis of [sup 131]I containing waste-aster. (author) 4 refs.; 3 figs.

  16. Determination of lithium in organic matrix by potentiometric titration using fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Govindan, R.; Alamelu, D.; Shah, Raju; Aggarwal, S.K.

    2008-01-01

    A method has been developed for the determination of lithium (Li) present in organic matrix containing hexa methylene tetramine (HMTA) and urea used in the sol-gel process for preparing lithium titanate microspheres, using fluoride ion selective electrode and potentiometric end point. Lithium is present in the wash solutions of the Sol-Gel process employed for the preparation of lithium titanate microspheres, proposed to be used in TBM (Test Blanket Module) of International Thermonuclear Experimental Reactor (ITER) project. Methods such as ICP-AES, AAS etc. used in aqueous solutions cannot be employed directly for lithium determination in organic matrix containing hexa methylene tetramine (HMTA), urea, NH 4 NO 3 , NH 4 Cl etc. A potentiometric method using a combination fluoride ion selective electrode for end point detection was developed and has been employed for lithium determination in the process streams from sol-gel process. The method is simple and rapid and an accuracy of about 0.5 % was achieved for the determination of Li in the range of 1 to 20 mg. The method is based on the complexation of Li by adding a known excess of NH 4 F solution, followed by potentiometric end point detection using fluoride ISE

  17. Fusion of Potentiometric & Voltammetric Electronic Tongue for Classification of Black Tea Taste based on Theaflavins (TF) Content

    Science.gov (United States)

    Bhattacharyya, Nabarun; Legin, Andrey; Papieva, Irina; Sarkar, Subrata; Kirsanov, Dmitry; Kartsova, Anna; Ghosh, Arunangshu; Bandyopadhyay, Rajib

    2011-09-01

    Black tea is an extensively consumed beverage worldwide with an expanding market. The final quality of black tea depends upon number of chemical compounds present in the tea. Out of these compounds, theaflavins (TF), which is responsible for astringency in black tea, plays an important role in determining the final taste of the finished black tea. The present paper reports our effort to correlate the theaflavins contents with the voltammetric and potentiometric electronic tongue (e-tongue) data. Noble metal-based electrode array has been used for collecting data though voltammetric electronic tongue where as liquid filled membrane based electrodes have been used for potentiometric electronic tongue. Black tea samples with tea taster score and biochemical results have been collected from Tea Research Association, Tocklai, India for the analysis purpose. In this paper, voltammetric and potentiometric e-tongue responses are combined to demonstrate improvement of cluster formation among tea samples with different ranges of TF values.

  18. [Determination of mercury in Boletus impolitus by flow injection-atomic absorption spectrometry].

    Science.gov (United States)

    Li, Tao; Wang, Yuan-Zhong

    2008-04-01

    Various test conditions and effect factors for the determination of mercury by flow injection-atomic absorption spectrometry were discussed, and a method for the determination of mercury in Boletus impolitus has been developed. The linear range for mercury is 0-60 microg x L(-1). The relative standard deviation is less than 3.0%, and the recovery is 96%-107%. This method is simple, rapid and has been applied to the determination of mercury in Boletus impolitus samples with satisfactory results.

  19. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    OpenAIRE

    Gervasio,Ana P. G.; Miranda,Carlos E. S.; Luca,Gilmara C.; Tumang,Cristiane A.; Campos,Luis F. P.; Reis,Boaventura F.

    2001-01-01

    A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major constituents such as Fe(III) and Cr(III), a mini-column packed with AG50W-X8 resin was coupled to the manifold. A sample throughput of 40 determinations per hour, a dynamical range from P 0...

  20. Structural characterization of hexadecyltrimethylammonium-smectite composites and their potentiometric electrode applications

    Energy Technology Data Exchange (ETDEWEB)

    Cubuk, Osman [Department of Chemistry, Faculty of Arts and Sciences, Erzincan University, 24100 Erzincan (Turkey); Caglar, Bulent, E-mail: bcaglar55@gmail.com [Department of Chemistry, Faculty of Arts and Sciences, Erzincan University, 24100 Erzincan (Turkey); Topcu, Cihan; Coldur, Fatih; Sarp, Gokhan [Department of Chemistry, Faculty of Arts and Sciences, Erzincan University, 24100 Erzincan (Turkey); Tabak, Ahmet [Department of Chemistry, Faculty of Arts and Sciences, Recep Tayyip Erdoğan University, 53100 Rize (Turkey); Sahin, Erdal [Department of Chemistry, Faculty of Arts and Sciences, Erzincan University, 24100 Erzincan (Turkey)

    2015-05-30

    Graphical abstract: - Highlights: • Surfactant cations intercalated with different molecular arrangements into smectite layers. • The electrophoretic mobility values indicate that excess surfactant loadings also create positive charges on the organosmectites surfaces. • A novel potentiometric SCN{sup −} selective electrode was fabricated based on modified smectite. - Abstract: Organosmectites were prepared by the intercalation of hexadecyltrimethylammonium cations at various ratios into interlayer of Unye smectite. Structural, thermal, morphological and textural properties of the synthesized organosmectites were characterized. Afterwards, a novel potentiometric PVC-membrane thiocyanate selective electrode was prepared based on the obtained hexadecyltrimethylammonium modified smectites as electroactive material. The basal spacing values of organosmectites were observed in the range of 15.61 and 35.50 Å. Powder X-ray diffraction data show that the surfactant cations penetrated into the smectite layers with different molecular arrangements. Modification of smectite with hexadecyltrimethylammonium led to appreciable decreases in the intensities of the FTIR bands at 3402 and 1635 cm{sup −1} and the new characteristic vibrational bands at 2927, 2850, 1472 and 722 cm{sup −1} originating from the surfactant molecules appeared. The thermal analysis data showed that the decomposition of surfactant species occurred in the temperature range of 170–720 °C and the amount of dehydrated water gradually decreased with the increase in surfactant amount. The intercalation of surfactant species within the gallery spacing led gradually to smaller surface areas. In addition, the electrophoretic mobility values indicate that excess surfactant loadings also generate positive charges on the organosmectite surfaces. The most convenient membrane composition resulting in the best potentiometric performance was investigated. The optimum membrane composition was determined to

  1. Semi-automatic version of the potentiometric titration method for characterization of uranium compounds

    International Nuclear Information System (INIS)

    Cristiano, Bárbara F.G.; Delgado, José Ubiratan; Wanderley S da Silva, José; Barros, Pedro D. de; Araújo, Radier M.S. de; Dias, Fábio C.; Lopes, Ricardo T.

    2012-01-01

    The potentiometric titration method was used for characterization of uranium compounds to be applied in intercomparison programs. The method is applied with traceability assured using a potassium dichromate primary standard. A semi-automatic version was developed to reduce the analysis time and the operator variation. The standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization and compatible with those obtained by manual techniques. - Highlights: ► A semi-automatic potentiometric titration method was developed for U charaterization. ► K 2 Cr 2 O 7 was the only certified reference material used. ► Values obtained for U 3 O 8 samples were consistent with certified. ► Uncertainty of 0.01% was useful for characterization and intercomparison program.

  2. Ni(III) - a new oxidant for the potentiometric determination of plutonium

    International Nuclear Information System (INIS)

    Gopinath, N.; Rama Rao, G.A.; Natarajan, P.R.

    1986-01-01

    Ni(III) was employed as an oxidant for the quantitative oxidation of plutonium to its hexavalent state and this makes possible to determine plutonium concentrations potentiometrically by the Fe(II)-dichromate redox titration method. The unreacted oxidant is completely reduced by sulphamic acid prior to the determination of plutonium. (author)

  3. Status of understanding of the saturated-zone ground-water flow system at Yucca Mountain, Nevada, as of 1995

    Energy Technology Data Exchange (ETDEWEB)

    Luckey, R.R.; Tucci, P.; Faunt, C.C.; Ervin, E.M. [and others

    1996-12-31

    Yucca Mountain, which is being studied extensively because it is a potential site for a high-level radioactive-waste repository, consists of a thick sequence of volcanic rocks of Tertiary age that are underlain, at least to the southeast, by carbonate rocks of Paleozoic age. Stratigraphic units important to the hydrology of the area include the alluvium, pyroclastic rocks of Miocene age (the Timber Mountain Group; the Paintbrush Group; the Calico Hills Formation; the Crater Flat Group; the Lithic Ridge Tuff; and older tuffs, flows, and lavas beneath the Lithic Ridge Tuff), and sedimentary rocks of Paleozoic age. The saturated zone generally occurs in the Calico Hills Formation and stratigraphically lower units. The saturated zone is divided into three aquifers and two confining units. The flow system at Yucca Mountain is part of the Alkali Flat-Furnace Creek subbasin of the Death Valley groundwater basin. Variations in the gradients of the potentiometric surface provided the basis for subdividing the Yucca Mountain area into zones of: (1) large hydraulic gradient where potentiometric levels change at least 300 meters in a few kilometers; (2) moderate hydraulic gradient where potentiometric levels change about 45 meters in a few kilometers; and (3) small hydraulic gradient where potentiometric levels change only about 2 meters in several kilometers. Vertical hydraulic gradients were measured in only a few boreholes around Yucca Mountain; most boreholes had little change in potentiometric levels with depth. Limited hydraulic testing of boreholes in the Yucca Mountain area indicated that the range in transmissivity was more than 2 to 3 orders of magnitude in a particular hydrogeologic unit, and that the average values for the individual hydrogeologic units generally differed by about 1 order of magnitude. The upper volcanic aquifer seems to be the most permeable hydrogeologic unit, but this conclusion was based on exceedingly limited data.

  4. Status of understanding of the saturated-zone ground-water flow system at Yucca Mountain, Nevada, as of 1995

    International Nuclear Information System (INIS)

    Luckey, R.R.; Tucci, P.; Faunt, C.C.; Ervin, E.M.

    1996-01-01

    Yucca Mountain, which is being studied extensively because it is a potential site for a high-level radioactive-waste repository, consists of a thick sequence of volcanic rocks of Tertiary age that are underlain, at least to the southeast, by carbonate rocks of Paleozoic age. Stratigraphic units important to the hydrology of the area include the alluvium, pyroclastic rocks of Miocene age (the Timber Mountain Group; the Paintbrush Group; the Calico Hills Formation; the Crater Flat Group; the Lithic Ridge Tuff; and older tuffs, flows, and lavas beneath the Lithic Ridge Tuff), and sedimentary rocks of Paleozoic age. The saturated zone generally occurs in the Calico Hills Formation and stratigraphically lower units. The saturated zone is divided into three aquifers and two confining units. The flow system at Yucca Mountain is part of the Alkali Flat-Furnace Creek subbasin of the Death Valley groundwater basin. Variations in the gradients of the potentiometric surface provided the basis for subdividing the Yucca Mountain area into zones of: (1) large hydraulic gradient where potentiometric levels change at least 300 meters in a few kilometers; (2) moderate hydraulic gradient where potentiometric levels change about 45 meters in a few kilometers; and (3) small hydraulic gradient where potentiometric levels change only about 2 meters in several kilometers. Vertical hydraulic gradients were measured in only a few boreholes around Yucca Mountain; most boreholes had little change in potentiometric levels with depth. Limited hydraulic testing of boreholes in the Yucca Mountain area indicated that the range in transmissivity was more than 2 to 3 orders of magnitude in a particular hydrogeologic unit, and that the average values for the individual hydrogeologic units generally differed by about 1 order of magnitude. The upper volcanic aquifer seems to be the most permeable hydrogeologic unit, but this conclusion was based on exceedingly limited data

  5. Transmicrocatheter local injection of ethanol to treat hepatocellular carcinoma with high flow arteriovenous shunts

    International Nuclear Information System (INIS)

    Guan Shouhai; Shan Hong; Jiang Zaibo; Huang Mingsheng; Zhu Kangshun; Li Zhengran; Meng Xiaochun

    2002-01-01

    Objective: To evaluate the feasibility and clinical effect of embolization therapy in treating the high flow hepatic arteriovenous shunts in hepatocellular carcinoma (HCC) by locally injected ethanol through microcatheter. Methods: Forty-one branches of arteriovenous shunts were treated by local ethanol infusion through microcatheter in 29 patients suffered with HCC. Angiography was performed to observe the embolization effect and influence to non-targeted vessels. Result: Forty-one branches of arteriovenous shunts in 29 patients were injected with ethanol locally. Each single shunt was infused 1-6 times. The dose of ethanol was 2-3 ml per time, and the total dose of ethanol was 2-12 ml. All shunting tracts were embolized, and all non-target vessels were protected fluently. Iodine-oil deposition was well in continued TACE. Their syndromes were improved or disappeared. Conclusion: Transmicrocatheter injection of ethanol could safely and effectively treat the hepatic arteriovenous shunts and make advantages to TACE in HCC

  6. Calculation method of water injection forward modeling and inversion process in oilfield water injection network

    Science.gov (United States)

    Liu, Long; Liu, Wei

    2018-04-01

    A forward modeling and inversion algorithm is adopted in order to determine the water injection plan in the oilfield water injection network. The main idea of the algorithm is shown as follows: firstly, the oilfield water injection network is inversely calculated. The pumping station demand flow is calculated. Then, forward modeling calculation is carried out for judging whether all water injection wells meet the requirements of injection allocation or not. If all water injection wells meet the requirements of injection allocation, calculation is stopped, otherwise the demand injection allocation flow rate of certain step size is reduced aiming at water injection wells which do not meet requirements, and next iterative operation is started. It is not necessary to list the algorithm into water injection network system algorithm, which can be realized easily. Iterative method is used, which is suitable for computer programming. Experimental result shows that the algorithm is fast and accurate.

  7. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  8. A two-fluid model for vertical flow applied to CO2 injection wells

    DEFF Research Database (Denmark)

    Linga, Gaute; Lund, Halvor

    2016-01-01

    Flow of CO2 in wells is associated with substantial variations in thermophysical properties downhole, due to the coupled transient processes involved: complex flow patterns, density changes, phase transitions, and heat transfer to and from surroundings. Large temperature variations can lead...... the well, including tubing, packer fluid, casing, cement or drilling mud, and rock formation. This enables prediction of the temperature in the well fluid and in each layer of the well. The model is applied to sudden shut-in and blowout cases of a CO2 injection well, where we employ the highly accurate...

  9. Study of process parameters effect on the filling phase of micro injection moulding using weld lines as flow markers

    DEFF Research Database (Denmark)

    Tosello, Guido; Gava, Alberto; Hansen, Hans Nørgaard

    2010-01-01

    , the relationships between the filling pattern and the different process parameter settings have to be established. In this paper, a novel approach based on the use of weld lines as flow markers to trace the development of the flow front during the filling is proposed. The effects on the filling stage of process......Micro-injection moulding (micro-moulding) is a process which enables the mass production of polymer microproducts. In order to produce high-quality injection moulded micro-parts, a crucial aspect to be fully understood and optimised is the filling of the cavity by the molten polymer. As a result...... manufactured by micro-electrodischarge machining. A commercially available polystyrene grade polymer has been moulded using a high-speed injection moulding machine. The design of experiment technique was employed to determine the effect of the process parameters on the filling phase of the micro...

  10. Direct evidence of ionic fluxes across ion-selective membranes: a scanning electrochemical microscopic and potentiometric study.

    Science.gov (United States)

    Gyurcsányi, R E; Pergel, E; Nagy, R; Kapui, I; Lan, B T; Tóth, K; Bitter, I; Lindner, E

    2001-05-01

    Scanning electrochemical microscopy (SECM) supplemented with potentiometric measurements was used to follow the time-dependent buildup of a steady-state diffusion layer at the aqueous-phase boundary of lead ion-selective electrodes (ISEs). Differential pulse voltammetry is adapted to SECM for probing the local concentration profiles at the sample side of solvent polymeric membranes. Major factors affecting the membrane transport-related surface concentrations were identified from SECM data and the potentiometric transients obtained under different experimental conditions (inner filling solution composition, membrane thickness, surface pretreatment). The amperometrically determined surface concentrations correlated well with the lower detection limits of the lead ion-selective electrodes.

  11. Characterization of Native and Modified Starches by Potentiometric Titration

    OpenAIRE

    Soto, Diana; Urdaneta, Jose; Pernia, Kelly

    2014-01-01

    The use of potentiometric titration for the analysis and characterization of native and modified starches is highlighted. The polyelectrolytic behavior of oxidized starches (thermal and thermal-chemical oxidation), a graft copolymer of itaconic acid (IA) onto starch, and starch esters (mono- and diester itaconate) was compared with the behavior of native starch, the homopolymer, and the acid employed as a graft monomer and substituent. Starch esters showed higher percentages of acidity, follo...

  12. Adaptation of a load-inject valve for a flow injection chemiluminescence system enabling dual-reagent injection enhances understanding of environmental Fenton chemistry

    International Nuclear Information System (INIS)

    Jones, Matthew R.; Nightingale, Philp D.; Turner, Suzanne M.; Liss, Peter S.

    2013-01-01

    Graphical abstract: -- Highlights: •Measurement of multiple components of Fenton chemistry; Fe(II) and H 2 O 2 . •Rapid, quasi-simultaneous analysis enables calculation of environmental kinetics. •Low, nano to pico-molar detection limits with dual analyte analysis. •Able to measure complex matrix samples – organically enriched seawater. •Low cost system with appreciable sensitivity compared to single analyte analysis. -- Abstract: Environmental Fenton chemistry has been poorly constrained within the marine environment at a multi-component level. A simple, unique, reconfiguration of a flow-injection analytical system combined with luminol chemiluminescence allows quasi-simultaneously the measurement, using a single load-inject valve and a single photon multiplier tube, of reduced iron, Fe(II), and hydrogen peroxide. The system enables rapid, every 22 s, measurements with good accuracy at environmentally relevant concentrations, less than 5% relative standard deviations on both a 5 nM Fe(II) standard and a 60 nM hydrogen peroxide standard. Limits of detection were as low as 40 pM Fe(II) and 100 pM hydrogen peroxide. The system showed excellent capability by measuring from within an organic rich seawater the photochemically induced production of Fe(II) and hydrogen peroxide and their subsequent cycling and Fenton like interactions

  13. Determination of uranium and plutonium in PFBR MOX fuel using automatic potentiometric titrator

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Meena, D.L.; Singh, Mamta; Kapoor, Y.S.; Pabale, Sagar; Fulzele, Ajit; Das, D.K.; Behere, P.G.; Afzal, Mohd

    2014-01-01

    Present paper describes the automatic potentiometric method for the determination of uranium and plutonium in less complexing H 2 SO 4 with scaling down the reagent volumes 15-20 ml in order to minimize the waste generation

  14. Cerebral blood flow in the occlusive cerebrovascular disease. 133Xe intravenous injection method

    Energy Technology Data Exchange (ETDEWEB)

    Kuda, Hitoshi; Mukawa, Jiro; Takara, Eiichi; Kinjo, Toshihiko; Ishikawa, Yasunari

    1988-04-01

    From December 1985 to May 1986, cerebral blood flow (CBF) was studied in 11 patients with occlusive cerebrovascular diseases confined by angiography. 133Xe (5mci) intravenous injection method designed by Kuikka and coworkers was applied for the measurement of regional-CBF and mean-CBF, and the calculation was based on the initial slope index. They were composed of 4 patients of the middle cerebral artery occlusion, 2 of the posterior cerebral artery occlusion, 1 of the internal carotid artery occlusion, 2 of the middle cerebral artery stenosis, 1 of the internal carotid artery stenosis, and 1 of the anterior cerebral artery stenosis. The period from the vascular attack to the initial CBF study was 2-29 days(mean 9.2 days). Recovery of mean-CBF was correlated with clinical and neurological improvement, and vice versa. There was no correlation between mean-CBF and neurological severity. CBF study alone is not sufficient to evaluate neuronal conditions in the occlusive disease. Additional other means, such as CT-scan, angiography and etc. should be requested for it. Intravenous 133Xe injection technique has an advantage over intracarotid injection method; less dangerous, especially in ages and capable of simultaneous measurement of bilateral hemisphere. Considering /sup c/ross talk/sup /regional-CBF of a low density area on X-ray CT-scan was equal to the one obtained by intracarotid injection method.

  15. Regional cerebral blod flow studied by xenon-133. Intra-arterial injection studies and inhalation studies using emission tomography

    DEFF Research Database (Denmark)

    Lassen, N A

    1980-01-01

    .) technique is insensitive both to hyperemia and ischemia yielding essentially only a mean flow value. A new rapidly moving single photon tomograph following D. Kuhl's principle is presented applicable to Xe-133. Preliminary clinical data show that this technique is able to detect ischemic areas both with Xe......A survey of the Xenon-133 techniques for measurement of regional cerebral blood flow, rCBF, in man is presented. The intra-arterial Xe-133 injection method is very sensitive for detecting even small hyperemic areas, but cannot "see" smaller ischemic areas. The Xe-133 inhalation (or i.v. inj......-133 intra-arterial injection and with Xe-133 inhalation. The practical and economic advantages of Xe-133 or Xe-127 tomography over positron tomography for rCBF are discussed....

  16. Instabilities and prediction of the acoustic resonance of flows with wall injection; Instabilites et prevision de l'accrochage acoustique des ecoulements avec injection parietale

    Energy Technology Data Exchange (ETDEWEB)

    Avalon, G. [Office National d' Etudes et de Recherches Aerospatiales (ONERA), 91 - Palaiseau (France); Casalis, G. [Office National d' Etudes et de Recherches Aerospatiales (ONERA), 91 - Palaiseau (France)

    1998-07-01

    Aero-acoustic coupling that occurs inside solid propellant rocket engines can lead to a longitudinal acoustic mode resonance of the combustion chamber. This phenomenon, which can have various origins, in analyzed using the Vecla test facility and the theory of linear stability of flows. Different comparisons between the hot-wire measurements performed and the theory of stability confirm the presence of intrinsic instabilities for this type of flow. The instability allows to selectively amplify a given range of frequencies which depends on the injection velocity and on the conduit height. The results obtained seem to indicate that when this frequency range does not comprise the longitudinal acoustic mode or the first harmonics, the flow becomes turbulent downstream. (J.S.)

  17. Flow injection spectrofluorimetric method for the determination of cadmium

    International Nuclear Information System (INIS)

    Bo Tang; Taixing Yue; Lili Zhang; Junsen Wu; Zhenzhen Chen

    2004-01-01

    A novel fluorescent reagent, o-vanillin furoylhydrazone (OVFH), was synthesized, and its infrared spectrum, elemental analysis and dissociation constant are reported. The reaction between Cd 2+ and OVFH produces an intensely fluorescent complex in ethanol-water medium of pH 10.00, and this finding has led to a simple, rapid, and sensitive flow injection (FI) spectrofluorimetric method for on-line determination of Cd 2+ . Under the optimum experimental conditions, the fluorescent complex had excitation and emission maxima at 393 and 494 nm, respectively. The linear range is from 0.025 to 8.0 μg mL -1 of Cd 2+ , the detection limit is 7.6 μg L -1 and the maximum sampling rate is 80 h -1 . The effect of interferences was studied. The method was successfully applied to the determination of cadmium in environmental samples. (author)

  18. Potentiometric microdetermination of cadmium in organic compounds after oxygen flask combustion

    International Nuclear Information System (INIS)

    Campiglio, A.

    1986-01-01

    The sample is burnt in an oxygen flask and the combustion products are absorbed in 1Μ HNO 3 . After removal of interfering gases by boiling, the solution is transfered to the titration cell and neutralized with NaOH in the presence of methyl red; cd(II) is finally titrated potentiometrically in a buffered 50% ethanolic medium with 0.01Μ sodium diethyldithiocarbamate in 50% ethanol. A silver/sulphide ion-selective electrode and a double junction referenceelectrode containing a 10% KNO 3 solution in 26% ethanol in the outer compartment are used in combination with a Titroprocessor to detect the end point. The results obtained are very accurate and reproducible: the maximum error does not exceed 0.09%, the recovery of cadmium is in the range 99.67 to 99.95% and the rel. standard deviation is 0.05%. The potentiometric titration with diethyldithiocarbamate, which is useful to determine small Cd(II) amounts down to 30μg (2μg ml -1 ), as well as the oxygen flask combustion of organic cadmium compounds are discussed. (Author)

  19. Combinatorial screening of potentiometric Pb(II) sensors from polysulfoaminoanthraquinone solid ionophore.

    Science.gov (United States)

    Huang, Mei-Rong; Ding, Yong-Bo; Li, Xin-Gui

    2014-03-10

    A potentiometric Pb(II)-selective sensor was fabricated by a combinatorial screening of electrically conducting polysulfoaminoanthraquinone (PSA) nanoparticles as a solid ionophore, ion exchangers (oleic acid (OA) and NaTPB), plasticizers in a polyvinyl chloride (PVC) matrix, membrane thickness, inner filling ion species, and concentration. The membrane sensor with the composition of PSA/PVC/DOP (dioctyl phthalate)/OA (1.0:33:61:5.0) exhibited the best performance, including a slope of 29.3 mV decade(-1) in the concentration range 10(-6.3)-10(-1.6) M, detection limit of 1.6 × 10(-7) M, response time of 16 s, lifetime of five months, and good response reversibility. The proposed sensor has demonstrated good selectivity for Pb(II) over other monovalent, divalent and trivalent interfering ions, and could be used in a pH range of 3.62-5.22. The Pb(II) sensor has been successfully applied for the determination of Pb(II) concentration in real-world samples and also as an indicator electrode for potentiometric titration of lead ions.

  20. New potentiometric sensor based on molecularly imprinted nanoparticles for cocaine detection.

    Science.gov (United States)

    Smolinska-Kempisty, K; Ahmad, O Sheej; Guerreiro, A; Karim, K; Piletska, E; Piletsky, S

    2017-10-15

    Here we present a potentiometric sensor for cocaine detection based on molecularly imprinted polymer nanoparticles (nanoMIPs) produced by the solid-phase imprinting method. The composition of polymers with high affinity for cocaine was optimised using molecular modelling. Four compositions were selected and polymers prepared using two protocols: chemical polymerisation in water and UV-initiated polymerisation in organic solvent. All synthesised nanoparticles had very good affinity to cocaine with dissociation constants between 0.6nM and 5.3nM. Imprinted polymers produced in organic solvent using acrylamide as a functional monomer demonstrated the highest yield and affinity, and so were selected for further sensor development. For this, nanoparticles were incorporated within a PVC matrix which was then used to prepare an ion-selective membrane integrated with a potentiometric transducer. It was demonstrated that the sensor was able to quantify cocaine in blood serum samples in the range of concentrations between 1nM and 1mM. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Potentiometric surface of the Upper Patapsco aquifer in southern Maryland, September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the potentiometric surface of the upper Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland during September 2009. The map is based on water-level measurements in 65 wells. The highest measured water level was 118 feet above sea level near the northern boundary and outcrop area of the aquifer in northern Anne Arundel County. From this area, the potentiometric surface declined to the south toward a well field in the Annapolis-Arnold area, and from all directions toward three additional cones of depression. These cones are located in the Waldorf-La Plata area, Chalk Point, and the Leonardtown-Lexington Park area. The lowest measured groundwater levels were 26 feet below sea level at Annapolis, 108 feet below sea level south of Waldorf, 60 feet below sea level at Chalk Point, and 83 feet below sea level at Leonardtown. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  2. One-shot flow injection spectrophotometric simultaneous determination of copper, iron and zinc in patients' sera with newly developed multi-compartment flow cell

    International Nuclear Information System (INIS)

    Teshima, Norio; Gotoh, Shingo; Ida, Kazunori; Sakai, Tadao

    2006-01-01

    We propose here an affordable flow injection method for simultaneous spectrophotometric determination of copper, iron and zinc in patients' sera. The use of a newly designed multi-compartment flow cell allowed the simultaneous determination of the three metals with a single injection ('one-shot') and a double beam spectrophotometer. The chemistry relied on the reactions of these metals with 2-(5-nitro-2-pyridylazo)-5-[N-propyl-N-(3-sulfopropyl)amino]phenol (nitro-PAPS) to form corresponding colored complexes. At pH 3.8, only copper-nitro-PAPS complex was formed in the presence of pyrophosphate as a masking agent for iron, and then the copper and iron(II) complexes were formed in the presence of reductant (ascorbic acid) at the same pH, and finally all three metals reacted with nitro-PAPS at pH 8.6. The characteristics were introduced into the flow system to determine each metal selectively and sensitively. Under the optimum conditions, linear calibration curves for the three metals were obtained in the range of 0.01-1 mg L -1 with a sample throughput rate of 20 h -1 . The limits of detection (3σ) were 3.9 μg L -1 for copper, 4.1 μg L -1 for iron and 4.0 μg L -1 for zinc. The proposed method was applied to analysis of some patients' sera

  3. Semi-automated potentiometric titration method for uranium characterization.

    Science.gov (United States)

    Cristiano, B F G; Delgado, J U; da Silva, J W S; de Barros, P D; de Araújo, R M S; Lopes, R T

    2012-07-01

    The manual version of the potentiometric titration method has been used for certification and characterization of uranium compounds. In order to reduce the analysis time and the influence of the analyst, a semi-automatic version of the method was developed in the Brazilian Nuclear Energy Commission. The method was applied with traceability assured by using a potassium dichromate primary standard. The combined standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Study on effect of mixing mechanism by the transverse gaseous injection flow in scramjet engine with variable parameters

    Science.gov (United States)

    Yadav, Siddhita; Pandey, K. M.

    2018-04-01

    In scramjet engine the mixing mechanism of fuel and atmospheric air is very complicated, because the fuel have time in milliseconds for mixing with atmospheric air in combustion chamber having supersonic speed. Mixing efficiency of fuel and atmospheric air depends on mainly these parameters: Aspect ratio of injector, vibration amplitude, shock type, number of injector, jet to transverse flow momentum flux ratio, injector geometry, injection angle, molecular weight, incoming air stream angle, jet to transverse flow pressure ratio, spacing variation, mass flow rate of fuel etc. here is a very brief study of these parameters from previously done research on these parameters for the improvement of mixing efficiency. The mixing process have the significant role for the working of engine, and mixing between the atmospheric air and the jet fuel is significant factor for improving the overall thrust of the engine. The results obtained by study of papers are obtained by the 3D-Reynolds Average-Nervier-Stokes(RANS) equations along with the 2-equation k-ω shear-stress-transport (SST) turbulence model. Engine having multi air jets have 60% more mixing efficiency than single air jet, thus if the jets are increased, the mixing efficiency of engine can also be increased up to 150% by changing jet from 1 to 16. When using delta shape of injector the mixing efficiency is inversely proportional to the pressure ratio. When the fuel is injected inside the combustor from the top and bottom walls of the engine efficiency of mixing in reacting zone is higher than the single wall injection and in comparison to parallel flow, the transverse type flow is better as the atmospheric air jet can penetrate smoothly in the fuel jets and mixes well in less time. Hence this study of parameters and their effects on mixing can enhance the efficiency of mixing in engine.

  5. Geological Factors Affecting Flow Spatial Continuity in Water Injection of Units Operating in the LGITJ–0102 Ore Body

    Directory of Open Access Journals (Sweden)

    Ilver M. Soto-Loaiza

    2016-05-01

    Full Text Available The objective of the investigation was to identify the geological factors affecting the spatial continuity of the flow during the process of flank water injection in the units operating in the Lower Lagunilla Hydrocarbon Ore Body. This included the evaluation of the recovery factor, the petro-physic properties such as porosity, permeability, water saturation and rock type and quality in each flow unit. it was observed that the rock type of the geologic structure in the ore body is variable. The lowest values for the petro-physic properties were found in the southern area while a high variability of these parameters was observed in the northern and central areas. It was concluded that the northern area has a great potential for the development of new injection projects for petroleum recovery.

  6. Potentiometric surface of the upper Floridan aquifer, west-central Florida, May 2011

    Science.gov (United States)

    Ortiz, Anita G.

    2011-01-01

    The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2011. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when groundwater levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 45.74 inches for west-central Florida (from June 2010 through May 2011) was 6.85 inches below the historical cumulative average of 52.59 inches (Southwest Florida Water Management District, 2011). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September from 1975 through 2010. Water-level data are collected in May and September each year to

  7. Use of the potentiometric titration method to investigate heterogeneous systems including phosphorylated complexones

    International Nuclear Information System (INIS)

    Tereshin, G.S.; Kharitonova, L.K.; Kuznetsova, O.B.

    1979-01-01

    Heterogeneous systems Y(NO 3 ) 3 (YCl 3 )-Hsub(n)L-KNO 3 (KCl)-H 2 O are investigated by potentiometric titration (with coulomb-meter generation of oH - ions). Hsub(n)L is one of the following: oxyethylidendiphosphonic; aminobenzilidendiphosphonic; glycine-bis-methyl-phosphonic; nitrilotrimethylphosphonic (H 6 L) and ethylenediaminetetramethylphosphonic acids. The range of the exsistence of YHsub(nL3)LxyH 2 O has been determined. The possibility of using potentiometric titration for investigating heterogeneous systems is demonstrated by the stUdy of the system Y(NO 3 ) 3 -H 6 L-KOH-H 2 o by the method of residual concentration. The two methods have shown that at pH 3 LxyH 2 O; at pH=6, KYH 2 Lxy'H 2 O, and at pH=7, K 2 YHLxy''H 2 O. The complete solubility products of nitrilotrimethylphosphonates are evaluated

  8. Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2013-01-01

    RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

  9. Flow injection analysis simulations and diffusion coefficient determination by stochastic and deterministic optimization methods.

    Science.gov (United States)

    Kucza, Witold

    2013-07-25

    Stochastic and deterministic simulations of dispersion in cylindrical channels on the Poiseuille flow have been presented. The random walk (stochastic) and the uniform dispersion (deterministic) models have been used for computations of flow injection analysis responses. These methods coupled with the genetic algorithm and the Levenberg-Marquardt optimization methods, respectively, have been applied for determination of diffusion coefficients. The diffusion coefficients of fluorescein sodium, potassium hexacyanoferrate and potassium dichromate have been determined by means of the presented methods and FIA responses that are available in literature. The best-fit results agree with each other and with experimental data thus validating both presented approaches. Copyright © 2013 The Author. Published by Elsevier B.V. All rights reserved.

  10. Three-dimensional numerical simulation for plastic injection-compression molding

    Science.gov (United States)

    Zhang, Yun; Yu, Wenjie; Liang, Junjie; Lang, Jianlin; Li, Dequn

    2018-03-01

    Compared with conventional injection molding, injection-compression molding can mold optical parts with higher precision and lower flow residual stress. However, the melt flow process in a closed cavity becomes more complex because of the moving cavity boundary during compression and the nonlinear problems caused by non-Newtonian polymer melt. In this study, a 3D simulation method was developed for injection-compression molding. In this method, arbitrary Lagrangian- Eulerian was introduced to model the moving-boundary flow problem in the compression stage. The non-Newtonian characteristics and compressibility of the polymer melt were considered. The melt flow and pressure distribution in the cavity were investigated by using the proposed simulation method and compared with those of injection molding. Results reveal that the fountain flow effect becomes significant when the cavity thickness increases during compression. The back flow also plays an important role in the flow pattern and redistribution of cavity pressure. The discrepancy in pressures at different points along the flow path is complicated rather than monotonically decreased in injection molding.

  11. Impact of physical properties of biodiesel on the injection process in a common-rail direct injection system

    International Nuclear Information System (INIS)

    Boudy, Frederic; Seers, Patrice

    2009-01-01

    This paper presents the influence of biodiesel fuel properties on the injection mass flow rate of a diesel common-rail injection system. Simulations are first performed with ISO 4113 diesel fuel on a four-cylinder common-rail system to evaluate a single and triple injection strategies. For each injection strategy, the impact of modifying a single fuel property at a time is evaluated so as to quantify its influence on the injection process. The results show that fuel density is the main property that affects the injection process, such as total mass injected and pressure wave in the common-rail system. The fuel's viscosity and bulk modulus also influence, but to a lessen degree, the mass flow rate of the injector notably during multiple injection strategies as individual properties change the fuel's dampening property and friction coefficient.

  12. The Difference Between the Potentiometric Surfaces of the Magothy Aquifer in Southern Maryland, September 1975 and September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the change in the potentiometric surface of the Magothy aquifer in the Magothy Formation of Late Cretaceous age in Southern Maryland for September 1975 and September 2007. The map, based on water-level measurements in 51 wells, shows that during the 32-year period, the potentiometric surface had no change at the outcrop area, which is in the northernmost part of the study area, but declined 90 feet at Waldorf. Waldorf is located near the southwesternmost part of the study area, and approaches the downdip boundary of the aquifer.

  13. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine.

    Science.gov (United States)

    Nery, Emilia Witkowska; Kubota, Lauro T

    2016-04-28

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca(2+)/Mg(2+), K(+)/Na(+)) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only describes new

  14. New potentiometric and spectrophotometric methods for the determination of dextromethorphan in pharmaceutical preparations.

    Science.gov (United States)

    Elmosallamy, Mohamed A F; Amin, Alaa S

    2014-01-01

    New, simple and convenient potentiometric and spectrophotometric methods are described for the determination of dextromethorphan hydrobromide (DXM) in pharmaceutical preparations. The potentiometric technique is based on developing a potentiometric sensor incorporating the dextromethorphan tetrakis(p-chlorophenyl)borate ion-pair complex as an electroactive species in a plasticized PVC matrix membrane with o-nitophenyl octyl ether or dioctyl phthalate. The sensor shows a rapid near Nernstian response of over 1 × 10(-5) - 1 × 10(-2) mol L(-1) dextromethorphan in the pH range of 3.0 - 9.0. The detection limit is 2 × 10(-6) mol L(-1) DXM and the response time is instantaneous (2 s). The proposed spectrophotometric technique involves the reaction of DXM with eriochrom black T (EBT) to form an ion-associate complex. Solvent extraction is used to improve the selectivity of the method. The optimal extraction and reaction conditions have been studied, and the analytical characteristics of the method have been obtained. Linearity is obeyed in the range of 7.37 - 73.7 × 10(-5) mol L(-1) DXM, and the detection limit of the method is 1.29 × 10(-5) mol L(-1). The relative standard deviation (RSD) and relative error for six replicate measurements of 3.685 × 10(-4) mol L(-1) are 0.672 and 0.855%, respectively. The interference effect of some excepients has also been tested. The drug contents in pharmaceutical preparations were successfully determined by the proposed methods by applying the standard-addition technique.

  15. Status report: numerical modeling of ground-water flow in the Paleozoic formations, western Paradox Basin, Utah

    International Nuclear Information System (INIS)

    Dunbar, D.B.; Thackston, J.W.

    1985-10-01

    A three-dimensional finite-difference numerical model was applied to simulate the ground-water flow pattern in Paleozoic strata within the western Paradox Basin region. The primary purpose of the modeling was to test the present conceptual hydrogeologic model and evaluate data deficiencies. All available data on ground-water hydrology, although sparse in this area, were utilized as input to the model. Permeability and potentiometric levels were estimated from petroleum company drill-stem tests and water-supply wells; formation thicknesses were obtained from geologic correlation of borehole geophysical logs. Hydrogeologic judgment weighed heavily in the assignment of hydrologic values to geologic features for this preliminary modeling study. Calibration of the model was accomplished through trial-and-error matching of simulated potentiometric contours with available head data. Hypothetical flow patterns, flux rates, recharge amounts, and surface discharge amounts were produced by the model. 34 refs., 17 figs., 3 tabs

  16. Flow injection spectrophotometric determination of low concentrations of orthosphate in natural waters employing ion exchange resin

    International Nuclear Information System (INIS)

    Pessenda, L.C.R.

    1981-01-01

    A simple and fast method for the determination of low concentrations of orthophosphate in natural waters is described. Ion exchange is incorporated into a flow injection system by usina a resin column in the sample loop of a proportion injector. Effects of sample aspiration rate, sampling time, eluting agent concentration, pumping rate of the sample carrier stream and interfaces, were investigated both using 32 PO 3- 4 or 31 PO 3- 4 with columns coupled to a gerger-muller detector and incorporated in a flow system with molybdenum blue colorinetry. (M.A.C.) [pt

  17. Computer analysis of potentiometric data of complexes formation in the solution

    Science.gov (United States)

    Jastrzab, Renata; Kaczmarek, Małgorzata T.; Tylkowski, Bartosz; Odani, Akira

    2018-02-01

    The determination of equilibrium constants is an important process for many branches of chemistry. In this review we provide the readers with a discussion on computer methods which have been applied for elaboration of potentiometric experimental data generated during complexes formation in solution. The review describes both: general basis of modeling tools and examples of the use of calculated stability constants.

  18. Effect of cross-flow direction of coolant on film cooling effectiveness with one inlet and double outlet hole injection

    Directory of Open Access Journals (Sweden)

    Guangchao Li

    2012-12-01

    Full Text Available In order to study the effect of cross-flow directions of an internal coolant on film cooling performance, the discharge coefficients and film cooling effectiveness with one inlet and double outlet hole injections were simulated. The numerical results show that two different cross-flow directions of the coolant cause the same decrease in the discharge coefficients as that in the case of supplying coolant by a plenum. The different proportion of the mass flow out of the two outlets of the film hole results in different values of the film cooling effectiveness for three different cases of coolant supplies. The film cooling effectiveness is the highest for the case of supplying coolant by the plenum. At a lower blowing ratio of 1.0, the film cooling effectiveness with coolant injection from the right entrance of the passage is higher than that from the left entrance of the passage. At a higher blowing ratio of 2.0, the opposite result is found.

  19. A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples.

    Science.gov (United States)

    Koronkiewicz, Stanislawa; Trifescu, Mihaela; Smoczynski, Lech; Ratnaweera, Harsha; Kalinowski, Slawomir

    2018-02-12

    The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneously, in counter-current into the reaction-detection chamber by the system of specially selected for this purpose solenoid micro-pumps. The micro-pumps provided good precision and accuracy of the injected volumes. For the determination of orthophosphates, the molybdenum blue method was employed. The developed method can be used to detect orthophosphate in the range 0.1-12 mg L -1 , with the repeatability (RSD) about 2.2% at 4 mg L -1 and a very high injection throughput of 120 injections h -1 . It was possible to achieve a very small consumption of reagents (10 μL of ammonium molybdate and 10 μL of ascorbic acid) and sample (20 μL). The volume of generated waste was only 440 μL per analysis. The method has been successfully applied, giving a good accuracy, to determination of orthophosphates in complex matrix samples: treated wastewater, lake water and reference sample of groundwater. The developed system is compact, small in both size and weight, requires 12 V in supply voltage, which are desirable for truly portable equipment used in routine analysis. The simplicity of the system should result in its greater long-time reliability comparing to other flow methods previously described.

  20. Solute transport in streams of varying morphology inferred from a high resolution network of potentiometric wireless chloride sensors

    Science.gov (United States)

    Klaus, Julian; Smettem, Keith; Pfister, Laurent; Harris, Nick

    2017-04-01

    There is ongoing interest in understanding and quantifying the travel times and dispersion of solutes moving through stream environments, including the hyporheic zone and/or in-channel dead zones where retention affects biogeochemical cycling processes that are critical to stream ecosystem functioning. Modelling these transport and retention processes requires acquisition of tracer data from injection experiments where the concentrations are recorded downstream. Such experiments are often time consuming and costly, which may be the reason many modelling studies of chemical transport have tended to rely on relatively few well documented field case studies. This leads to the need of fast and cheap distributed sensor arrays that respond instantly and record chemical transport at points of interest on timescales of seconds at various locations in the stream environment. To tackle this challenge we present data from several tracer experiments carried out in the Attert river catchment in Luxembourg employing low-cost (in the order of a euro per sensor) potentiometric chloride sensors in a distributed array. We injected NaCl under various baseflow conditions in streams of different morphologies and observed solute transport at various distances and locations. This data is used to benchmark the sensors to data obtained from more expensive electrical conductivity meters. Furthermore, the data allowed spatial resolution of hydrodynamic mixing processes and identification of chemical 'dead zones' in the study reaches.

  1. Preliminary three-dimensional potential flow simulation of a five-liter flask air injection experiment

    International Nuclear Information System (INIS)

    Davis, J.E.

    1977-01-01

    The preliminary results of an unsteady three-dimensional potential flow analysis of a five-liter flask air injection experiment (small-scale model simulation of a nuclear reactor steam condensation system) are presented. The location and velocity of the free water surface in the flask as a function of time are determined during pipe venting and bubble expansion processes. The analyses were performed using an extended version of the NASA-Ames Three-Dimensional Potential Flow Analysis System (POTFAN), which uses the vortex lattice singularity method of potential flow analysis. The pressure boundary condition at the free water surface and the boundary condition along the free jet boundary near the pipe exit were ignored for the purposes of the present study. The results of the analysis indicate that large time steps can be taken without significantly reducing the accuracy of the solutions and that the assumption of inviscid flow should not have an appreciable effect on the geometry and velocity of the free water surface. In addition, the computation time required for the solutions was well within acceptable limits

  2. Continuous-flow ultrasound assisted oxidative desulfurization (UAOD) process: An efficient diesel treatment by injection of the aqueous phase.

    Science.gov (United States)

    Rahimi, Masoud; Shahhosseini, Shahrokh; Movahedirad, Salman

    2017-11-01

    A new continuous-flow ultrasound assisted oxidative desulfurization (UAOD) process was developed in order to decrease energy and aqueous phase consumption. In this process the aqueous phase is injected below the horn tip leading to enhanced mixing of the phases. Diesel fuel as the oil phase with sulfur content of 1550ppmw and an appropriate mixture of hydrogen peroxide and formic acid as the aqueous phase were used. At the first step, the optimized condition for the sulfur removal has been obtained in the batch mode operation. Hence, the effect of more important oxidation parameters; oxidant-to-sulfur molar ratio, acid-to-sulfur molar ratio and sonication time were investigated. Then the optimized conditions were obtained using Response Surface Methodology (RSM) technique. Afterwards, some experiments corresponding to the best batch condition and also with objective of minimizing the residence time and aqueous phase to fuel volume ratio have been conducted in a newly designed double-compartment reactor with injection of the aqueous phase to evaluate the process in a continuous flow operation. In addition, the effect of nozzle diameter has been examined. Significant improvement on the sulfur removal was observed specially in lower sonication time in the case of dispersion method in comparison with the conventional contact between two phases. Ultimately, the flow pattern induced by ultrasonic device, and also injection of the aqueous phase were analyzed quantitatively and qualitatively by capturing the sequential images. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Maria-Cristina Radulescu

    2014-01-01

    Full Text Available A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX, carboxyl esterase (CaE and bovine serum albumin (BSA were immobilised with glutaraldehyde (GA onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC. The biosensor response was fast. The sample throughput using a flow injection analysis (FIA system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples without any pre-treatment step prior to measurement.

  4. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    Science.gov (United States)

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  5. BIOSENSOR FOR DIRECT DETERMINATION OF ORGANOPHOSPHATE NERVE AGENTS. 1. POTENTIOMETRIC ENZYME ELECTRODE. (R823663)

    Science.gov (United States)

    A potentiometric enzyme electrode for the direct measurement of organophosphate (OP)nerve agents was developed. The basic element of this enzyme electrode was a pH electrodemodified with an immobilized organophosphorus hydrolase (OPH) layer formed by cross-linkingOPH ...

  6. Clinical studies on the lymph flow of the esophagus by injecting sup(99m)Tc-rhenium colloid into the esophageal wall

    International Nuclear Information System (INIS)

    Baba, Masamichi; Tanabe, Gen; Nishi, Mitsumasa

    1985-01-01

    Using 29 operative cases lymph flow of the esophagus was investigated by injecting endoscopically sup(99m)Tc-Rhenium colloid. Rhenium colloid lymphoscintigraphy was made, and 30 -- 32 hours after injection RI up take (cpm/g) of resected lymph nodes was counted by scintillation counter. 1. RI up take of resected lymph nodes correspond with the lymphoscintigraphy of resected lymph nodes therefore, RI up take count was available to study the extra-mural lymph flow of the esophagus. 2. In the cases injected at upper part of the esophagus, the high counted RI up take was noted in bifurcation lymph nodes, upper mediastinal lymph nodes and bilateral supraclavicular lymph nodes. In the cases injected at middle part of the esophagus, bilateral supraclavicular lymph nodes, upper mediastinal lymph nodes and left gastric artery lymph nodes revealed the high RI up takes. In the cases injected at lower part of the esophagus, RI up take was highly noted in bifurcation lymph nodes, left gastric artery lymph nodes and celiac axis lymph nodes. In the cases injected at esophago-gastric junction, the high counted RI up take was noted in left gastric artery lymph nodes, celiac axis lymph nodes and the lymph nodes around the left renal vein. 3. In the cases injected at upper, middle parts of the esophagus, bilateral supraclavicular lymph nodes revealed the high RI up take. Some of these lymph nodes are regarded as directly connected with the extra-mural lymph vessls of the esophagus. Therefore, it was suggested that existence of ''direct lymph flow'' from which upper, middle intrathoracic esophagus directly connected to right supraclavicular lymph nodes. 4. It is important to perform bilateral modified neck dissection in case of upper, middle intrathoracic esophageal cancer and is important to dissect the lymph nodes around the left renal vein in case of esophago-gastric cancer and lower intrathoracic esophageal cancer. (J.P.N.)

  7. Enzyme-based Colorimetric and Potentiometric Biosensor for Detecting Pb (II Ions in Milk

    Directory of Open Access Journals (Sweden)

    Hardeep Kaur

    2014-08-01

    Full Text Available The aim of the present work was to study a simple colorimetric and potentiometric biosensor based on urease inhibition by Pb (II ions for its estimation in milk samples. Urease immobilized on nylon membrane by hydrosol gel method was used as the biocomponent to demonstrate the metal effect on the enzyme activity using phenol red as the pH indicator. A lower limit detection of 38.6µm was achieved in the milk and the enzyme membranes were stable for more than two months at 4ºC. In potentiometric approach, response of an ion selective electrode (ISE to changing ammonium ion concentration as a consequence of urease inhibition by Pb (II ions was explored to achieve a detection limit of 9.66 µm. Lead specificity was attained by means of masking agents 1,10 - phenanthroline and sodium potassium tartarate. Validation of the developed biosensors was carried out with spiked milk samples.

  8. Experimental Investigation of Diffuser Hub Injection to Improve Centrifugal Compressor Stability

    Science.gov (United States)

    Skoch, Gary J.

    2004-01-01

    Results from a series of experiments to investigate whether centrifugal compressor stability could be improved by injecting air through the diffuser hub surface are reported. The research was conducted in a 4:1 pressure ratio centrifugal compressor configured with a vane-island diffuser. Injector nozzles were located just upstream of the leading edge of the diffuser vanes. Nozzle orientations were set to produce injected streams angled at 8, 0 and +8 degrees relative to the vane mean camber line. Several injection flow rates were tested using both an external air supply and recirculation from the diffuser exit. Compressor flow range did not improve at any injection flow rate that was tested. Compressor flow range did improve slightly at zero injection due to the flow resistance created by injector openings on the hub surface. Leading edge loading and semi-vaneless space diffusion showed trends similar to those reported earlier from shroud surface experiments that did improve compressor flow range. Opposite trends are seen for hub injection cases where compressor flow range decreased. The hub injection data further explain the range improvement provided by shroud-side injection and suggest that different hub-side techniques may produce range improvement in centrifugal compressors.

  9. Potentiometric Surface of the Lower Patapsco Aquifer in Southern Maryland, September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the potentiometric surface of the lower Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland during September 2007. The map is based on water-level measurements in 65 wells. The highest measured water level was 111 feet above sea level near the northwestern boundary and outcrop area of the aquifer in northern Prince George's County. From this area, the potentiometric surface declined towards well fields at Severndale and Arnold. The measured ground-water levels were 87 feet below sea level at Severndale, and 42 feet below sea level at Arnold. There was also a cone of depression covering a large area in Charles County that includes Waldorf, La Plata, Indian Head, and the Morgantown power plant. The ground-water levels measured were as low as 219 feet below sea level at Waldorf, 187 feet below sea level at La Plata, 106 feet below sea level at Indian Head, and 89 feet below sea level at the Morgantown power plant.

  10. Potentiometric Surface of the Upper Patapsco Aquifer in Southern Maryland, September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the potentiometric surface of the upper Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland during September 2007. The map is based on water-level measurements in 50 wells. The highest measured water level was 120 feet above sea level near the northern boundary and outcrop area of the aquifer in northern Anne Arundel County. From this area, the potentiometric surface declined to the south toward a well field in the Annapolis-Arnold area, and from all directions toward four cones of depression. These cones are located in the Waldorf-La Plata area, Chalk Point-Prince Frederick area, Swan Point subdivision in southern Charles County, and the Lexington Park-St. Inigoes area. The lowest measured ground-water level was 44 feet below sea level at Arnold, 106 feet below sea level south of Waldorf, 54 feet below sea level at Swan Point, 59 feet below sea level at Chalk Point, and 58 feet below sea level at Lexington Park.

  11. Reverse-Tangent Injection in a Centrifugal Compressor

    Science.gov (United States)

    Skoch, Gary J.

    2007-01-01

    Injection of working fluid into a centrifugal compressor in the reverse tangent direction has been invented as a way of preventing flow instabilities (stall and surge) or restoring stability when stall or surge has already commenced. The invention applies, in particular, to a centrifugal compressor, the diffuser of which contains vanes that divide the flow into channels oriented partly radially and partly tangentially. In reverse-tangent injection, a stream or jet of the working fluid (the fluid that is compressed) is injected into the vaneless annular region between the blades of the impeller and the vanes of the diffuser. As used here, "reverse" signifies that the injected flow opposes (and thereby reduces) the tangential component of the velocity of the impeller discharge. At the same time, the injected jet acts to increase the radial component of the velocity of the impeller discharge.

  12. Application of a field flow preconcentration system with a minicolumn packed with amberlite XAD-4/1-(2-pyridylazo)-2-naphtol and a flow injection-flame atomic adsorption spectrometric system for lead determination in sea water

    International Nuclear Information System (INIS)

    Carmen Yebra, M. del; Rodriguez, L.; Puig, L.; Moreno-Cid, A.

    2002-01-01

    A field flow preconcentration technique involving a minicolumn containing Amberlite XAD-4 impregnated with the complexing agent 1-(2-pyridylazo)-2-naphthol was used to preconcentrate lead from seawater. Elution of retained lead on the minicolumns was performed by a flow-injection-flame atomic absorption spectrometric system. Factorial designs have been used to optimize the field flow preconcentration system and the flow injection elution process. Factors such as sample pH, sample flow-rate, eluent concentration and volume (hydrochloric acid), elution flow-rate and minicolumn diameter were considered. The results suggest that the sample flow-rate and the eluent volume are statistically significant factors. The detection limit (3σ) of the procedure was 5 ng/L for a sample volume of 1000 ml. The precision (expressed as relative standard deviation) for eleven independent determinations reached values of 4.0-3.1 % in lead solutions of 50-200 ng/L. This procedure has been successfully applied to the determination of lead in seawater from Galicia (Spain). (author)

  13. Differential potentiometric titration: development of a methodology for determining the point of zero charge of metal (hydr)oxides by one titration curve.

    Science.gov (United States)

    Bourikas, Kyriakos; Kordulis, Christos; Lycourghiotis, Alexis

    2005-06-01

    A new methodology is presented, called differential potentiometric titration (DPT), which allows the determination of the point of zero charge (pzc) of metal (hydr)oxides using only one potentiometric curve. By performing extensive simulations of potentiometric titrations for various model (hydr)oxides, we found that an inflection point in a H+(cons,surf) versus pH potentiometric curve (H+(cons,surf): hydrogen ions consumed on the surface of the (hydr)oxide) and a peak in the corresponding differential curve, dH+(cons,surf)/dpH versus pH, appear at a pH equal to the pzc assumed for a model (hydr)oxide. This distinguishable peak appears at the same position irrespective of the surface ionization and the interfacial model adopted as well as the assumed ionic strength. It was found that the aforementioned peak also appears in the high-resolution differential potentiometric curves experimentally determined for four oxides (SiO2, TiO2, gamma-Al2O3, and MgO) that are widely used in various environmental and other technological applications. The application of DPT to the above-mentioned oxides provided practically the same pzc values as the corresponding ones achieved by using four different techniques as well as the corresponding isoelectric point (iep) values determined by microelectrophoresis. Differences between the pzc and iep values determined using various techniques in the case of MgO were attributed to the increasing dissolution of this oxide as pH decreases and the adsorption of cations (Mg2+, Na+) on the MgO/electrolytic solution interface.

  14. Potentiometric titrations of para and nitro substituted aromatic acids and their mixtures in methylethyl ketone

    International Nuclear Information System (INIS)

    Ozeroglu, C.; Karahan, M.

    2011-01-01

    In this study, it was the purpose to examine the potentiometric titrations of para and nitro substituted aromatic acids in methylethyl ketone (MEK) as a non-aqueous solvent. Good analytical results were obtained in determining the amount of each acid and the amounts of acids in their ternary mixtures by using 0.0964 N tetrabuthylammoniumhydroxyde (TBAH) as a standard titrant. Methylethyl ketone (MEK) which is a good solvent for many organic compounds and has a convenient liquid range of -86 to 80 deg. C was used for titration of the para and nitro substituted aromatic acids. A linear relationship has been found between pKa values of the para and nitro substituted aromatic acids in water and the half neutralization potential (HNP) values determined by potentiometric titration curves of the same acids in MEK. (author)

  15. Combined Voltammetric-Potentiometric Sensor with the Silver Solid Amalgam Link for Electroanalytical Measurements

    Czech Academy of Sciences Publication Activity Database

    Josypčuk, Bohdan; Novotný, Ladislav

    2002-01-01

    Roč. 14, č. 24 (2002), s. 1739-1741 ISSN 1040-0397 R&D Projects: GA ČR GV204/97/K084 Institutional research plan: CEZ:AV0Z4040901 Keywords : combined voltammetric-potentiometric sensors * solid amalgam Subject RIV: CG - Electrochemistry Impact factor: 1.783, year: 2002

  16. Calculating Equilibrium Constants in the SnCl2-H2O-NaOH System According to Potentiometric Titration Data

    Science.gov (United States)

    Maskaeva, L. N.; Fedorova, E. A.; Yusupov, R. A.; Markov, V. F.

    2018-05-01

    The potentiometric titration of tin chloride SnCl2 is performed in the concentration range of 0.00009-1.1 mol/L with a solution of sodium hydroxide NaOH. According to potentiometric titration data based on modeling equilibria in the SnCl2-H2O-NaOH system, basic equations are generated for the main processes, and instability constants are calculated for the resulting hydroxo complexes and equilibrium constants of low-soluble tin(II) compounds. The data will be of interest for specialists in the field of theory of solutions.

  17. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  18. Effect of Process Parameters on Flow Length and Flash Formation in Injection Moulding of High Aspect Ratio Polymeric Micro Features

    Directory of Open Access Journals (Sweden)

    Abdelkhalik Eladl

    2018-01-01

    Full Text Available This paper reports an investigation of the effects of process parameters on the quality characteristics of polymeric parts produced by micro injection moulding (μIM with two different materials. Four injection moulding process parameters (injection velocity, holding pressure, melt temperature and mould temperature were investigated using Polypropylene (PP and Acrylonitrile Butadiene Styrene (ABS. Three key characteristics of the mouldings were evaluated with respect to process settings and the material employed: part mass, flow length and flash formation. The experimentation employs a test part with four micro fingers with different aspect ratios (from 21 up to 150 and was carried out according to the Design of Experiments (DOE statistical technique. The results show that holding pressure and injection velocity are the most influential parameters on part mass with a direct effect for both materials. Both parameters have a similar effect on flow length for both PP and ABS at all aspect ratios and have higher effects as the feature thickness decreased below 300 μm. The study shows that for the investigated materials the injection speed and packing pressure were the most influential parameters for increasing the amount of flash formation, with relative effects consistent for both materials. Higher melt and mould temperatures settings were less influential parameters for increasing the flash amount when moulding with both materials. Of the two investigated materials, PP was the one exhibiting more flash formation as compared with ABS, when corresponding injection moulding parameters settings for both materials were considered.

  19. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  20. Determination of milligram amounts of neptunium by potentiometric titration

    International Nuclear Information System (INIS)

    Ryzhinskij, M.V.; Solntseva, L.F.

    1981-01-01

    Two procedures of potentiometric titration of about 1 mg Np are reported which are based on its oxidation to neptunium (6) with silver (2) oxide followed by titration with iron (2) to neptunium (5) in one case and to neptunium (4) in the alternative one. The error is not greater than 0.2% rel. Ten-fold uranium excess does not interfere. Up to 1% of plutonium relative to neptunium does not interfere in the case of the titration to neptunium (5). In the titration to neptunium (4), plutonium is titrated stoichiometrically [ru

  1. Persistence length of carboxymethyl cellulose as evaluated from size exclusion chromatography and potentiometric titrations.

    NARCIS (Netherlands)

    Hoogendam, C.W.; Keizer, de A.; Cohen Stuart, M.A.; Bijsterbosch, B.H.; Smit, J.A.M.; Dijk, van J.A.P.P.; Horst, van der P.M.; Batelaan, J.G.

    1998-01-01

    The intrinsic persistence length of carboxymethyl cellulose (CMC) is determined by size exclusion chromatography in combination with multiangle laser light scattering (SEC-MALLS) as well as from potentiometric titrations. Samples with degree of substitution (ds) ranging from 0.75 to 1.25 were

  2. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    International Nuclear Information System (INIS)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-01-01

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10 -5 to 0.26 μg ml -1 for calf thymus DNA and 5.0x10 -8 to 5.0x10 -5 μg ml -1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5x10 -6 μg ml -1 for calf thymus DNA and 4.3x10 -8 μg ml -1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed

  3. Numerical Simulations of Two-Phase Reacting Flow in a Single-Element Lean Direct Injection (LDI) Combustor Using NCC

    Science.gov (United States)

    Liu, Nan-Suey; Shih, Tsan-Hsing; Wey, C. Thomas

    2011-01-01

    A series of numerical simulations of Jet-A spray reacting flow in a single-element lean direct injection (LDI) combustor have been conducted by using the National Combustion Code (NCC). The simulations have been carried out using the time filtered Navier-Stokes (TFNS) approach ranging from the steady Reynolds-averaged Navier-Stokes (RANS), unsteady RANS (URANS), to the dynamic flow structure simulation (DFS). The sub-grid model employed for turbulent mixing and combustion includes the well-mixed model, the linear eddy mixing (LEM) model, and the filtered mass density function (FDF/PDF) model. The starting condition of the injected liquid spray is specified via empirical droplet size correlation, and a five-species single-step global reduced mechanism is employed for fuel chemistry. All the calculations use the same grid whose resolution is of the RANS type. Comparisons of results from various models are presented.

  4. Water injection profiling by nuclear logging

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1980-01-01

    This invention relates to nuclear logging techniques for determining the volume flow rates and flow directions of injected water moving behind a wellbore casing. The apparatus includes a sonde equipped with a neutron source and dual radiation detectors. Oxygen in the neutron irradiated water is transmitted to 16 N and the resultant primary and Compton scattered gamma rays are detected in two energy windows by both detectors. Count rate data is analysed in terms of the windows to obtain linear flow velocities for water flow within and behind the casing. Volume flow rates are determined for upward and downward flow, and horizontal volume flow into the surrounding formation is calculated. A complete injection profile may thus be obtained. (U.K.)

  5. Analytical and numerical solution of three-dimensional channel flow in presence of a sinusoidal fluid injection and a chemical reaction

    Directory of Open Access Journals (Sweden)

    Sahin Ahmed

    2015-06-01

    Full Text Available Modeling of three-dimensional channel flow in a chemically-reacting fluid between two long vertical parallel flat plates in the presence of a transverse magnetic field is presented. The stationary plate is subjected to a transverse sinusoidal injection velocity distribution while the uniformly moving plate is subjected to a constant suction and slip boundary conditions. Due to this type of injection velocity, the flow becomes three dimensional. Comparisons with previously published work are performed and the results are found to be in excellent agreement. An increase in the permeability/magnetic parameter is found to escalate the velocity near the plate in motion. Growing Reynolds number or magnetic parameter enhances the x-component and reduces the z-component of the skin-friction at the wall at rest. The acquired knowledge in our study can be used by designers to control MHD flow as suitable for certain applications which include laminar magneto-aerodynamics, materials processing and MHD propulsion thermo-fluid dynamics.

  6. Determination of binding constants of cyclodextrin inclusion complexes with amino acids and dipeptides by potentiometric titration.

    Science.gov (United States)

    Kahle, Claudia; Holzgrabe, Ulrike

    2004-10-01

    Cyclodextrins are well known for their ability to separate enantiomers of drugs, natural products, and other chiral substances using HPLC, GC, or CE. The resolution of the enantiomers is due to the formation of diastereomeric complexes between the cyclodextrin and the pairs of enantiomers. The aim of this study was to determine the binding constants of the complexes between alpha- and beta-cyclodextrin and the enantiomers of a series of aliphatic and aromatic amino acids, and dipeptides, using a potentiometric titration method. The results of this method are compared to other methods, and correlated to findings in cyclodextrin-modified capillary electrophoresis and possible complex structures. Potentiometric titration was found to be an appropriate tool to determine the binding constants of cyclodextrin inclusion complexes.

  7. Reduction of Altitude Diffuser Jet Noise Using Water Injection

    Science.gov (United States)

    Allgood, Daniel C.; Saunders, Grady P.; Langford, Lester A.

    2011-01-01

    A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

  8. Imaging diagnostics of ethanol port fuel injection sprays for automobile engine applications

    International Nuclear Information System (INIS)

    Padala, Srinivas; Le, Minh Khoi; Kook, Sanghoon; Hawkes, Evatt R.

    2013-01-01

    This paper presents characteristics of ethanol sprays at port fuel injection (PFI) conditions with variations in injection and ambient parameters. Details of temporal and spatial development of ethanol PFI sprays are studied using Mie-scattering and high-speed shadowgraph imaging techniques. Momentum flux-based injection rate measurement is also performed. The influences of fuel flow-rate, injection duration, and ambient air cross-flow are of particular interest in an effort to understand ethanol PFI spray characteristics that are relevant to automobile engines. For comparison purposes, the results from gasoline fuel are also presented. Ethanol flow-rate effects are studied using two injectors with different nozzle-hole sizes at a fixed injection pressure. From the experiments, it was found that the actual injection duration was longer for the higher flow-rate injector although an electronic pulse width was fixed. This was due to an extended delay in the injector needle closing as the flow resistance against the needle was increased for the high flow-rate injector. For liquid droplets, the larger hole size of the higher flow-rate injector caused a higher mean droplet diameter and higher number of droplets. Injection duration was also varied to study transient spray behaviour: short-injection sprays with the end-of-injection transient dominating the overall spray development were compared to long, steady-injection sprays. From Mie-scattering images, the number of droplets and mean droplet diameter were found to be less for the short injection sprays. Detailed analysis using an axial profile of the number of droplets and mean droplet diameter suggested that the observed trends were a result of increased evaporation rate near the nozzle after the end of injection. This was consistent with shadowgraph images showing no liquid regions but only the vapour-phase fuel near the nozzle. Under the influence of ambient air cross-flow, both mean droplet diameter and number of

  9. Optimum design of the injection duct system of a stenter machine

    Energy Technology Data Exchange (ETDEWEB)

    Juraeva, Makhsuda; Song, Dong Joo [Yeungnam University, Geyongsan (Korea, Republic of); Ryu, Kyung Jin [Ajou Motor College, Boryeong (Korea, Republic of)

    2017-05-15

    Stenter machines are used for drying fabrics in the textile industry and have a heater, injection duct system, and fans inside a chamber. The injection duct system has ducts and air-injecting holes. Plane-type injection duct systems were investigated to obtain uniform airflow at the air-injecting holes. The flow field of the injection duct systems was computed using ANSYS CFX with different heights of the duct end and different shapes for the air-injecting holes. There was a high mass flow rate at the air-injecting holes and high airflow circulation inside both plane-type and mountain-type ducts at the ends. The height of the duct end was varied between 40 mm and 160 mm. The injection duct systems were analyzed with four different shapes of air-injecting holes. The circular and elliptical holes had lower standard deviations of the mass flow rate than other shapes. Relatively uniform mass flow rates were obtained in the plane-type and mountain-type duct systems when the height of the duct end was 40 mm and the shape of the air-injecting holes was circular or elliptical. The developed injection duct systems were improved by obtaining a uniform mass flow rate at the air-injecting holes. A stenter prototype was fabricated with the developed injection duct system to confirm the numerical results. The developed injection duct system had better performance than the original system.

  10. New method for simultaneous determination of Fe(II) and Fe(III) in water using flow injection technique

    International Nuclear Information System (INIS)

    Kozak, J.; Gutowski, J.; Kozak, M.; Wieczorek, M.; Koscielniak, P.

    2010-01-01

    The method exploits the possibilities of flow injection gradient titration in a system of reversed flow with spectrophotometric detection. In the developed approach a small amount of titrant (EDTA) is injected into a stream of sample containing a mixture of indicators (sulfosalicylic acid and 1,10-phenanthroline). In acid environment sulfosalicylic acid forms a complex with Fe(III), whereas 1,10-phenanthroline forms a complex with Fe(II). Measurements are performed at wavelength λ = 530 nm when radiation is absorbed by both complexes. After injection EDTA replaces sulfosalicylic acid and forms with Fe(III) more stable colourless complex. As a result, a characteristic 'cut off' peak is registered with a width corresponding to the Fe(III) concentration and with a height corresponding to the Fe(II) concentration. Calibration was performed by titration of four two-component standard solutions of the Fe(II)/Fe(III) concentrations established in accordance with 2 2 factorial plan. The method was tested with the use of synthetic samples and then it was applied to the analysis of water samples taken from artesian wells. Under optimized experimental conditions Fe(II) and Fe(III) were determined with precision less than 0.8 and 2.5% (RSD) and accuracy less than 3.2 and 5.1% (relative error) within the concentration ranges of 0.1-3.0 and 0.9-3.5 mg L -1 of both analytes, respectively.

  11. Application of a novel metabolomic approach based on atmospheric pressure photoionization mass spectrometry using flow injection analysis for the study of Alzheimer's disease.

    Science.gov (United States)

    González-Domínguez, Raúl; García-Barrera, Tamara; Gómez-Ariza, José Luis

    2015-01-01

    The use of atmospheric pressure photoionization is not widespread in metabolomics, despite its considerable potential for the simultaneous analysis of compounds with diverse polarities. This work considers the development of a novel analytical approach based on flow injection analysis and atmospheric pressure photoionization mass spectrometry for rapid metabolic screening of serum samples. Several experimental parameters were optimized, such as type of dopant, flow injection solvent, and their flows, given that a careful selection of these variables is mandatory for a comprehensive analysis of metabolites. Toluene and methanol were the most suitable dopant and flow injection solvent, respectively. Moreover, analysis in negative mode required higher solvent and dopant flows (100 µl min(-1) and 40 µl min(-1), respectively) compared to positive mode (50 µl min(-1) and 20 µl min(-1)). Then, the optimized approach was used to elucidate metabolic alterations associated with Alzheimer's disease. Thereby, results confirm the increase of diacylglycerols, ceramides, ceramide-1-phosphate and free fatty acids, indicating membrane destabilization processes, and reduction of fatty acid amides and several neurotransmitters related to impairments in neuronal transmission, among others. Therefore, it could be concluded that this metabolomic tool presents a great potential for analysis of biological samples, considering its high-throughput screening capability, fast analysis and comprehensive metabolite coverage. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Transient performance analysis of pressurized safety injection tank with a partition

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo

    2015-01-01

    Highlights: • Functional performance of safety injection tanks with a partition is evaluated. • Effects of key design parameters are scrutinized. • Distinctive features of the flow in multi-unit safety injection tanks are explored. - Abstract: A parametric study has been performed to evaluate the functional performance of a pressurized multi-unit safety injection tank, which would be considered as one of the candidates for a passive safety injection system in a nuclear power plant. The influences of key design parameters including the orifice size, initial gas fraction, and resistance coefficients and operating condition on the injection flow rate are scrutinized with a discussion of the relevant flow features such as the choked flow of gas through an orifice and two interconnected regions of differing gaseous pressure. The obtained results indicate that a multi-unit safety injection tank can passively control the injection flow rate and provide a stable safety injection over a relatively long period even in the case of drastic depressurization of a reactor coolant system

  13. Automation of potentiometric titration for the determination of uranium in nuclear fuel materials

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Pandey, Ashish; Kapoor, Y.S.; Kumar, Manish; Singh, Mamta; Fulzele, Ajeet; Prakash, Amrit; Afzal, Mohd; Panakkal, J.P.

    2010-01-01

    Advanced Fuel Fabrication Facility is fabricating various types of mixed oxide fuels, namely for PHWR, BWR, FBTR and PFBR. Precise determination of uranium in MOX fuel sample is important to get desired burn up in the reactor. The modified Davies and Gray method is routinely used for the potentiometric titration of uranium

  14. Urinary bladder blood flow. I. Comparison of clearance of locally injected 99mtechnetium pertechnate and radioactive microsphere technique in dogs

    DEFF Research Database (Denmark)

    Krøyer, Kristian; Bülow, J; Nielsen, S L

    1990-01-01

    The blood flow of the dog urinary bladder measured by radioactive microsphere technique was compared to the clearance of locally injected 99mTechnetium pertechnate (99mTc) in the bladder wall. In semilogarithmic plots the 99mTc washout curves showed a multiexponential course. From the initial...... slopes (median 5.7 min) the bladder blood flow was calculated to be only 30-62% of the results obtained from the radioactive microsphere technique (blood flow in the muscular layer 21.7-44.8 ml/100 g/min). These lower values imply that the rate of removal of the hydrophilic tracer 99mTc at these flow...... blood flow....

  15. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Daniel J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Tfaily, Malak M. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Moore, Ronald J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; LaMarche, Brian L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Zheng, Xueyun [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Fillmore, Thomas L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Chu, Rosalie K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Weitz, Karl K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Monroe, Matthew E. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Kelly, Ryan T. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Smith, Richard D. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Baker, Erin S. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States

    2017-12-13

    To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

  16. Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Van Berkel, Gary J [ORNL

    2012-01-01

    The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

  17. Stuides on a Pb2+-selective electrode with a macrocyclic liquid membrane. Potentiometric determination of Pb2+ ions

    Directory of Open Access Journals (Sweden)

    MARIAN ISVORANU

    2006-12-01

    Full Text Available This paper presents experimental and theoretical data regarding the design, characterization and analytical applications of a non-expensive, liquid-membrane ion-selective electrode for Pb2+ ions. The membrane is a solution of the active complex formed by Pb2+ ions with dibenzo-18-crown-6-ionophore (DB-[18]-C-6 extracted in propylene carbonate (PC. The sucessful application of the developed electrode for the determination of Pb2+ ions in aqueos solution samples by direct potentiometry and potentiometric titration is presented. For the presented analytical results, there are insignificant systematic errors between the direct potentiometric method with the developed ion-selective electrode and atomic absorption spectrometry.

  18. Potentiometric urea biosensor utilizing nanobiocomposite of chitosan-iron oxide magnetic nanoparticles

    International Nuclear Information System (INIS)

    Ali, A; Israr, M Q; Sadaf, J R; Nur, O; Willander, M; AlSalhi, M S; Atif, M; Ansari, Anees A; Ahmed, E

    2013-01-01

    The iron oxide (Fe 3 O 4 ) magnetic nanoparticles have been fabricated through a simple, cheap and reproducible approach. Scanning electron microscope, x-rays powder diffraction of the fabricated nanoparticles. Furthermore, the fabrication of potentiometric urea biosensor is carried out through drop casting the initially prepared isopropanol and chitosan solution, containing Fe 3 O 4 nanoparticles, on the glass fiber filter with a diameter of 2 cm and a copper wire (of thickness −500 μm) has been utilized to extract the voltage signal from the functionalized nanoparticles. The functionalization of surface of the Fe 3 O 4 nanoparticles is obtained by the electrostatically immobilization of urease onto the nanobiocomposite of the chitosan- Fe 3 O 4 in order to enhance the sensitivity, specificity, stability and reusability of urea biosensor. Electrochemical detection procedure has been adopted to measure the potentiometric response over the wide logarithmic concentration range of the 0.1 mM to 80 mM. The Fe 3 O 4 nanoparticles based urea biosensor depicts good sensitivity with ∼42 mV per decade at room temperature. Durability of the biosensor could be considerably enhanced by applying a thin layer of the nafion. In addition, the reasonably stable output response of the biosensor has been found to be around 12 sec.

  19. Potentiometric assessment of iron release during ferritin reduction by exogenous agents.

    Science.gov (United States)

    Vladimirova, Lilia S; Kochev, Valery K

    2010-09-01

    This work studied the possibilities for quantitative determination of iron mobilization in connection with ferritin reduction by ascorbic acid (vitamin C) and sodium dithionite in vitro. The iron storage protein was incubated with an excess of reductant in aerobic conditions in the absence of complexing agents in the medium. The release of Fe(2+) was let to go to completion, and the overall content of Fe(2+) in the solution was evaluated with the aid of potentiometric titration using Ce(4+) as an oxidizing titrant. Results suggest a moderate iron efflux under the influence of the chosen reducing agents. Although such a reduction of the protein mineral core by dihydroxyfumarate contributes greatly to the iron mobilization, ferritin behavior with vitamin C and dithionite seems to be different. Although redox properties of dihydroxyfumarate are determined by hydroxyl groups similar to those of ascorbic acid, the two compounds differ significantly in structure, and this could be the basis for an explanation of the specificities in their interaction with ferritin. As revealed by the study, potentiometric titration promises to be a reliable tool for evaluation of the amount of Fe(2+) present in the solution as a result of the reduction of the ferritin's mineral core. 2010 Elsevier Inc. All rights reserved.

  20. Development of a novel MWCNTs-triazene-modified carbon paste electrode for potentiometric assessment of Hg(II) in the aquatic environments.

    Science.gov (United States)

    Mashhadizadeh, Mohammad Hossein; Ramezani, Soleyman; Rofouei, Mohammad Kazem

    2015-02-01

    In this approach, a new chemically modified carbon paste electrode was assembled for potentiometric assay of mercury(II) ion in the aqueous environments. Hereby, MWCNTs were used in the carbon paste composition to meliorate the electrical conductivity and sensitivity of the carbon paste owing to its exceptional physicochemical characteristics. Likewise, participation of the BEPT as a super-selective ionophore in the carbon paste composition boosted significantly the selectivity of the modified electrode towards Hg(II) ions over a wide concentration range of 4.0 × 10(-9)-2.2 × 10(-3) mol L(-1) with a lower detection limit of 3.1 × 10(-9) mol L(-1). Besides, Nernstian slope of the proposed sensor was 28.9(± 0.4)mV/decade over a pH range of 3.0-5.2 with potentiometric short response time of 10s. In the interim, by storing in the dark and cool dry place during non-usage period, the electrode can be used for at least 30 days without any momentous divergence of the potentiometric response. Eventually, to judge about its practical efficiency, the arranged sensor was utilized successfully as an indicator electrode for potentiometric titration of mercury(II) with standard solution of EDTA. As well, the quantitative analysis of mercury(II) ions in some aqueous samples with sensible accuracy and precision was satisfactorily performed. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Flow Injection Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1998-01-01

    Learning objectives:* To provide an introduction to automated assays* To describe the basic principles of FIA * To demonstrate the capabilities of FIA in relation to batch assays and conventional continuous flow systems* To show that FIA allows one to augment existing analytical techniques* To sh...... how FIA offers novel analytical procedures which are not feasible by conventional means* To hightlight the potentials of FIA in selected practical assays...

  2. Chemiluminescent determination of vanadium(IV) using a cinchomeronic hydrazide-H2O2 system and flow injection analysis

    International Nuclear Information System (INIS)

    Pradana Perez, J.A.; Alegria, J.S. Durand; Hernando, P. Fernandez; Sierra, A. Narros

    2005-01-01

    This paper proposes a new chemiluminescent flow injection analysis (FIA) method for the determination of vanadium(IV) ions in aqueous media. The method is based on the chemiluminescent reaction that occurs between cinchomeronic hydrazide (CH) and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. The chemical and physical variables involved in the flow injection system are optimised using a modified simplex method. Vanadium ions can be detected in the 0.08 and 1.00 μg mL -1 range; the detection limit for a signal-to-noise ratio of 3 is 0.08 μg mL -1 . Great variations in the quantum yield were observed when cobalt(II), chromium(III), copper(II) and/or nickel(II) were present in the reaction medium. The proposed method is selective and simple, and can be successfully used to analyse water samples without the need for separation or preconcentration processes

  3. The Difference Between the Potentiometric Surfaces of the Upper Patapsco Aquifer in Southern Maryland, September 1990 and September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the change in the potentiometric surface of the upper Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland for September 1990 and September 2007. The map, based on water-level measurements in 33 wells, shows that during the 17-year period, the change in the potentiometric surface ranged from zero at the edge of the outcrop area in northern Anne Arundel County to a decline of 28 feet at Crofton Meadows, 38 feet at Arnold, 36 feet at Waldorf, 35 feet at the Chalk Point power plant, and 40 feet at Lexington Park.

  4. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-02-12

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10{sup -5} to 0.26 {mu}g ml{sup -1} for calf thymus DNA and 5.0x10{sup -8} to 5.0x10{sup -5} {mu}g ml{sup -1} for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3{sigma}) are 6.5x10{sup -6} {mu}g ml{sup -1} for calf thymus DNA and 4.3x10{sup -8} {mu}g ml{sup -1} for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.

  5. A new potentiometric method for the estimation of the rare earth elements

    International Nuclear Information System (INIS)

    Selig, W.S.

    1988-01-01

    Chinese workers recently described a new potentiometric method for lead using sodium tetraphenylborate (NaTPB) as a titrant. Based on a previous Chinese publication, the authors have recently developed a method for the estimation of the alkaline earth metals by sequential titration with NaTPB. In the present work, the authors report a similar method for the estimation of the rare earth elements, including Sc and Y. The sensing electrode is a spectrographic graphite rod, coated with a solution of poly(vinyl chloride) and dioctylphthalate in tetrahydrofuran as previously described. The reference electrode was a double-junction Ag/AgCl electrode. The titration system is controlled by a Tektronix 4051 graphics computer system. Single cations or mixtures up to 0.5 mequiv are determined by potentiometric titration with 0.05 N NaTPB, after formation of the oxonium cations by reaction with an aqueous solution of poly(ethylene glycol) (PEG). Best results are obtained with PEGs of molecular weights from 8,000 to 20,000. Sequential estimation of Pb + Ba, Sr, and Ca, and the sum of the rare earth elements is also reported, plus possible applications to Al, Ga, and anions precipitated by lead

  6. Potentiometric Surface of the Lower Patapsco Aquifer in Southern Maryland, September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasin, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the potentiometric surface of the lower Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland during September 2009. The map is based on water-level measurements in 64 wells. The highest measured water level was 110 feet above sea level near the northwestern boundary and outcrop area of the aquifer in northern Prince George's County. From this area, the potentiometric surface declined towards well fields at Severndale, Broad Creek, and Arnold. The measured groundwater levels were 99 feet below sea level at Severndale, 50 feet below sea level at Broad Creek, and 36 feet below sea level at Arnold. There was also a cone of depression in Charles County that includes Waldorf, La Plata, Indian Head, and the Morgantown power plant. The groundwater levels measured were as low as 215 feet below sea level at Waldorf, 149 feet below sea level at La Plata, 121 feet below sea level at Indian Head, and 96 feet below sea level at the Morgantown power plant. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  7. Lead in Hair and in Red Wine by Potentiometric Stripping Analysis: The University Students' Design.

    Science.gov (United States)

    Josephsen, Jens

    1985-01-01

    A new program for training upper secondary school chemistry teachers (SE 537 693) depends heavily on student project work. A project in which lead in hair and in red wine was examined by potentiometric stripping analysis is described and evaluated. (JN)

  8. Determination of tellurium in lead and lead alloy using flow injection-hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mesko, Marcia F.; Pozebon, Dirce; Flores, Erico M.M.; Dressler, Valderi L.

    2004-01-01

    A method based on flow injection-hydride generation atomic absorption spectrometry (FI-HG AAS) for the determination of trace amount of Te in lead and lead alloy is described. A flow injection system (FI) and related analytical parameters as well as Te determination and interference caused by Pb, Bi and Ag on Te were investigated. The Pb interference could be overcome by using a small sample volume, while the Bi interference could be overcome by thiourea. However, it was not possible to minimise the interference caused by Ag on Te. The optimised conditions for Te determination in the analysed samples were: 6 mol l -1 HCl as sample carrier solution, 0.75% (m/v) sodium tetrahydroborate as Te reductant, 40 μl of sample solution, and 200 ml min -1 Ar flow rate as carrier gas. The limit of quantification (LOQ) was 1.0 μg g -1 Te (using 250 mg of sample in 50 ml final solution), the limit of detection (LOD) was 2.5 μg l -1 and the relative standard deviation (RSD) was 6% for five consecutive measurements of sample solution. The standard addition calibration method was used. Relatively high sample throughput (ca. 45 sample runs can be performed in a working hour), reduced sample manipulation since matrix separation is not necessary, and minor waste generation are the main advantages of the proposed method for Te determination by FI-HG AAS

  9. Potentiometric determination of sulfate with EDTA and the cupric-selective electrode

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1976-11-01

    Sulfate was indirectly determined by precipitating sulfate as BaSO 4 and then dissolving BaSO 4 in excess ammoniacal EDTA. The excess EDTA was titrated potentiometrically with La 3+ . A cupric-selective electrode was used to detect the end point. About 10 -3 M SO 4 2- was determined in 3M HCl solutions of metal oxides with a relative standard deviation of 3.5 percent and a bias of +4 percent

  10. Injection dynamics of gelled propellants

    Science.gov (United States)

    Yoon, Changjin

    Gel propellants have been recognized as attractive candidates for future propulsion systems due to the reduced tendency to spill and the energy advantages over solid propellants. One of strong benefits emphasized in gel propellant applications is a throttling capability, but the accurate flow control is more complicated and difficult than with conventional Newtonian propellants because of the unique rheological behaviors of gels. This study is a computational effort directed to enhance understanding of the injector internal flow characteristics for gel propellants under rocket injection conditions. In simulations, the emphasized rheology is a shear-thinning which represents a viscosity decrease with increasing a shear rate. It is described by a generalized Newtonian fluid constitutive equation and Carreau-Yasuda model. Using this rheological model, two injection schemes are considered in the present study: axially-fed and cross-fed injection for single-element and multi-element impinging injectors, respectively. An axisymmetric model is developed to describe the axially-fed injector flows and fully three-dimensional model is utilized to simulate cross-fed injector flows. Under axially-fed injection conditions investigated, three distinct modes, an unsteady, steady, and hydraulic flip mode, are observed and mapped in terms of Reynolds number and orifice design. In an unsteady mode, quasi-periodic oscillations occur near the inlet lip leading mass pulsations and viscosity fluctuations at the orifice exit. This dynamic behavior is characterized using a time-averaged discharge coefficient, oscillation magnitude and frequency by a parametric study with respect to an orifice design, Reynolds number and rheology. As a result, orifice exit flows for gel propellants appear to be significantly influenced by a viscous damping and flow resistance due to a shear thinning behavior and these are observed in each factors considered. Under conditions driven by a manifold crossflow

  11. Development of flow injection method for indirect copper determination with amperometric detection in drinking water samples

    Directory of Open Access Journals (Sweden)

    Nikolić-Mandić Snežana

    2012-01-01

    Full Text Available A gas-diffusion flow injection method with amperometric detection for indirect copper determination on a silver electrode is developed. The flow through system is equipped with two injection valves and a gas-diffusion unit. In the first step, a signal of cyanide solution was recorded. In the following step a signal of cyanide in the presence of copper was measured. Interferences (Cd(II, Co(II, Ag(I, Ni(II, Fe(III, Hg(II and Zn(II were investigated and successfully removed. The calibration graph is linear in the range 1-90 μmol dm-3 of copper, correlation coefficient is 0.993, the regression equation is I = (0.0455±0.0015c + (0.4611±0.0671, I is relative signal decrease in μA and c is concentration in μmol dm-3. Relative standard deviation for six consecutive injections of 30 μmol dm-3 copper(II was 1.47 % and for 1 μmol dm-3 copper(II was 3.40 %. The detection limit, calculated as 3 s/m (where s is a standard deviation of nine measurement of a reagent blank and m is the slope of the calibration curve, was 0.32 μmol dm-3, which corresponds to 2.44 ng of copper(II (loop volume was 0.12 cm3. The method enables 60 analyses per hour and it was successfully applied on determination of copper in drinking water samples. [Acknowledgements. The authors acknowledge the grant from the Ministry of Education and Science of the Republic of Serbia, Project number 172051

  12. Effect of intracoronary nitroprusside injection on flow recovery during primary PCI in acute STEMI patients.

    Science.gov (United States)

    Yang, Lixia; Mu, Lihua; Sun, Linhui; Qi, Feng; Guo, Ruiwei

    2017-04-01

    The no/slow reflow phenomenon during primary percutaneous coronary intervention (PPCI) causes the destruction of the coronary microcirculation and further myocardial damage. Some studies have shown that intracoronary nitroprusside infusion is a safe and effective method for managing the no/slow reflow phenomenon. However, it is uncertain whether the injection of nitroprusside at a specific time point during PPCI can most effectively prevent no-reflow. In this study, we investigated the effect of the timing of an intracoronary nitroprusside injection on flow recovery during PPCI in patients with ST elevation acute myocardial infarction (STEMI). One hundred twenty consecutive patients with STEMI who underwent PPCI were enrolled in the study. Patients who fulfilled the eligibility criteria were randomly allocated to three groups: control group (N.=40) received no nitroprusside before they completed PCI; the second group (N.=40) received nitroprusside before balloon dilatation; and the third group (N.=40) received nitroprusside after each balloon dilatation and before contrast agent refilling. The baseline clinical variables and the details of the PCI procedure were collected. The thrombolysis in myocardial infarction (TIMI) flow grades and the corrected TIMI frame count (cTFC) were evaluated immediately after stent implantation was completed. There were no significant differences in the baseline characteristics, antithrombotic drugs given before PCI, and details of the PCI procedure among the three groups (P>0.05). The incidence of TIMI grade 3 after PCI was significantly higher in the nitroprusside group than in the control group (P=0.025), whereas cTFC was significantly lower in the nitroprusside group (26.6±15.2) than in the control group (38.1±21.3, P=0.001). The incidence of TIMI grade 3 after PCI was significantly higher in the third group than in the second group (P=0.045), and cTFC was significantly lower in the third group (21.5±9.5) than in the second

  13. Modern Directions for Potentiometric Sensors

    Science.gov (United States)

    Bakker, Eric; Chumbimuni-Torres, Karin

    2009-01-01

    This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection limits of ISEs are described, including recent approaches of developing all solid state ISEs, and breakthroughs in detecting ultra-small quantities of ions at low concentrations. These developments have paved the way to use potentiometric sensors as in ultra-sensitive affinity bioanalysis in conjunction with nanoparticle labels. Recent results establish that potentiometry compares favorably to electrochemical stripping analysis. Other new developments with ion-selective electrodes are also described, including the concept of backside calibration potentiometry, controlled current coulometry, pulsed chronopotentiometry, and localized flash titration with ion-selective membranes to design sensors for the direct detection of total acidity without net sample perturbation. These developments have further opened the field for exciting new possibilities and applications. PMID:19890473

  14. Redox behaviour of molybdenum in aqueous medium : a potentiometric study

    International Nuclear Information System (INIS)

    Sagi, S.R.; Mohan Rao, P.R.

    1975-01-01

    The nature of the two forms; of Mo(III) cationic-aquomolybdenum(III) (green) and anionic-chloromolybdate(III) (orange-red) has been investigated using various oxidants in hydrochloric acid mdeium, the oxidation steps being detected using a potentiometric method. The two species behave differently towards the various oxidants. The green form is a better reducing agent giving large breaks in potentials during redox titrations. The existence of the intermediate oxidation states Mosup(3.5) and Mosup(4.5) reported earlier has also been confirmed. (author)

  15. Potentiometric study of Nd3+ chelates of substituted salicylhydroxamic acids

    International Nuclear Information System (INIS)

    Deshpande, R.G.; Jahagirdar, D.V.

    1976-01-01

    The interaction of Nd 3+ ion with salicylhydroxamic acid and 5-methyl, 5-chloro, 5-bromo, 5-nitro, 4-chloro, 4-bromo and 3-chloro salicylhydroxamic acids is investigated potentiometrically by Calvin-Bjerrum titration technique at 30 0 +- 0.1 0 and ionic strength μ=0.1 M(NaClO 4 ) in 50% v/v dioxane-water mixtures. Nd 3+ forms only 1:1 chelates with these ligands. The validity of the log K= apk + b relationship is examined for these chelates. (author)

  16. Stall margin improvement of an axial flow fan with end wall injection and suction; Hekimen fukidashi suidashi ni yoru han'yo jikuryu sofuki no shissoku kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, K.; Kuroda, H.; Obata, S.; Chimura, O. [National Defense Academy, Kanagawa (Japan)

    1999-06-25

    The experimental studies are conducted to reveal the mechanism of stall margin improvement of an axial flow fan by injection or suction from the end wall. In case of injection, the largest improvement is obtained by the injection at about 0. 14 {approx} 0 .21 times axial chord length downstream from leading edge. The reason for large improvement is that stall vortex, shed intermittent separation vortex and tip leakage vortex are dissipated by this injection, and also that this blowing suppresses the separation of boundary layer. In case of suction, the largest improvement is found for the suction from the end wall near leading edge. The amplitude of periodic static pressure after stall inception becomes smaller in comparison with injection cases. These effects are increased with the increase of suction flow rate, because the discharge of the vortex occurs more easily. On the other hand, the suction from the upstream of leading edge reduces the axial velocity near rotor tip, and then it induces stall. Also we tried to visualize the tip region flow, The suppression mechanism is discussed based on the visualization. The suppression of stall is successfully photographed. (author)

  17. Comparison of Flow Injection MS, NMR, and DNA Sequencing: Methods for Identification and Authentication of Black Cohosh (Actaea racemosa)

    Science.gov (United States)

    Flow injection mass spectrometry (FIMS) and proton nuclear magnetic resonance spectrometry (1H-NMR), two metabolic fingerprinting methods, and DNA sequencing were used to identify and authenticate Actaea species. Initially, samples of Actaea racemosa L. from a single source were distinguished from ...

  18. Mathematical Model of Two Phase Flow in Natural Draft Wet-Cooling Tower Including Flue Gas Injection

    Directory of Open Access Journals (Sweden)

    Hyhlík Tomáš

    2016-01-01

    Full Text Available The previously developed model of natural draft wet-cooling tower flow, heat and mass transfer is extended to be able to take into account the flow of supersaturated moist air. The two phase flow model is based on void fraction of gas phase which is included in the governing equations. Homogeneous equilibrium model, where the two phases are well mixed and have the same velocity, is used. The effect of flue gas injection is included into the developed mathematical model by using source terms in governing equations and by using momentum flux coefficient and kinetic energy flux coefficient. Heat and mass transfer in the fill zone is described by the system of ordinary differential equations, where the mass transfer is represented by measured fill Merkel number and heat transfer is calculated using prescribed Lewis factor.

  19. Research on injection characteristics of venturi scrubber worked in self-priming mode

    International Nuclear Information System (INIS)

    Zhou Yanmin; Sun Zhongning; Gu Haifeng; Miao Zhuang

    2015-01-01

    The injection characteristics of Venturi scrubber worked in self-priming mode in containment filter venting system was studied experimentally under different air flows, liquid levels and system pressures. The results indicate that with the increase of superficial gas velocity in throat, the static pressure drop of both sides of the suction grows approximately following a parabolic law, and the injection flow rate injecting into the Venturi scrubber increases linearly. The effect of liquid level on injection characteristics relates closely with the relative position to the outlet of the Venturi scrubber. When the liquid level is below the outlet, the injection flow rate improves significantly with increasing liquid level and presents a partition phenomenon, and in the low throat velocity, the increase of liquid level is more effective to improve the injection flow rate. However, when the liquid level is above the outlet, it almost has no impact on the injection flow rate. The pressure is another important factor affecting the injection characteristic of self-priming Venturi scrubber, which is mainly caused by the change on gas density. In the range of 0.150 kPa, with the increase of pressure, the injection flow rate improves greatly and the influence of pressure is more obvious in high throat velocity than in low throat velocity. (authors)

  20. Potentiometric titration of free acid in uranium solutions

    International Nuclear Information System (INIS)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors' researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors' researches are appended. (author). 26 refs., 54 figs

  1. Potentiometric titration of free acid in uranium solutions

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Kim, W. H.; Kim, J. S.; Sohn, S. C.; Eom, T. Y.; Lee, C. H.; Jeon, Y. S.; Han, S. H.

    1998-02-01

    Hydrolysis properties of metal cations and fundamental principles of the potentiometric titration of free acid in aqueous solutions containing metal cations were described. The published papers and reports for the alkalimetric and acidimetric titration of free acid were surveyed, and the applicability of these titration methods to the uranium and/or plutonium solutions were discussed. This technical report also includes the various results obtained from the authors` researches to establish the alkalimetric and acidimetric titration methods for the determination of free acid in nitric acid solutions containing uranium and/or oxalic acid, and aluminum. The procedure manuals used in chemical processes and the newly prepared manuals based on the authors` researches are appended. (author). 26 refs., 54 figs.

  2. Direct microcomputer controlled determination of zinc in human serum by flow injection atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Nielsen, Bent; Jensen, Arne

    1986-01-01

    A procedure is described for the direct determination of zinc in human serum by fully automated, microcomputer controlled flow injection atomic absorption spectrometry (Fl-AAS). The Fl system is pumpless, using the negative pressure created by the nebuliser. It only consists of a three-way valve......, programmable from the microcomputer, to control the sample volume. No pre-treatment of the samples is necessary. The limit of detection is 0.14 mg l–1, and only small amounts of serum (

  3. Micelle-mediated methodology for the preconcentration of uranium prior to its determination by flow injection

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Laespada, M E; Perez Pavon, J L; Moreno Cordero, B [Univ. de Salamanca (Spain). Dept. de Quimica Analitica, Nutricion y Bromatologia

    1993-02-01

    Cloud point extraction has been used for the preconcentration of uranium, prior to its determination by flow injection. The non-ionic surfactant employed was Triton X-114 and the reagent chosen to form a hydrophobic chelate of uranium was 1-(2-pyridylazo)-2-naphthol. The optimum conditions for the preconcentration and determination of uranium have been studied. This methodology has been applied to the determination of trace amounts of uranium in tap and river waters from Salamanca. (Author).

  4. On-line Speciation of Cr(III) and Cr(VI) by Flow Injection Analysis With Spectrophotometric Detection and Chemometrics

    DEFF Research Database (Denmark)

    Diacu, Elena; Andersen, Jens Enevold Thaulov

    2003-01-01

    A flow injection system has been developed, for on-line speciation. of Cr(III) and Cr(VI) by the Diphenylcarbazide (DPC) method with H2O2 oxidation followed by spectrophotometric detection at the 550 nm wavelength. The data thus obtained were subjected to a chemometric analysis (PLS), which showe...

  5. Flow-injection analysis of nitrate by reduction to nitrite and gas-phase molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Haghighi, B.; Tavassoli, A. [Dept. of Chemistry, Inst. for Advanced Studies in Basic Sciences, Zanjan (Iran)

    2001-12-01

    Two flow-injection manifolds have been investigated for the determination of nitrate. These manifolds are based on the reduction of nitrate to nitrite and determination of nitrite by gas-phase molecular absorption spectrophotometry. Nitrate sample solution (300 {mu}L) which is injected to the flow line, is reduced to nitrite by reaction with hydrazine or passage through the on-line copperized cadmium (Cd-Cu) reduction column. The nitrite produced reacts with a stream of hydrochloric acid and the evolved gases are purged into the stream of O{sub 2}carrier gas. The gaseous phase is separated from the liquid phase using a gas-liquid separator and then swept into a flow-through cell which has been positioned in the cell compartment of an UV-visible spectrophotometer. The absorbance of the gaseous phase is measured at 204.7 nm. A linear relationship was obtained between the intensity of absorption signals and concentration of nitrate when Cd-Cu reduction method was used, but a logarithmic relationship was obtained when the hydrazine reduction method was used. By use of the Cd-Cu reduction method, up to 330 {mu}g of nitrate was determined. The limit of detection was 2.97 {mu}g nitrate and the relative standard deviations for the determination of 12.0, 30.0 and 150 {mu}g nitrate were 3.32, 3.87 and 3.6%, respectively. Maximum sampling rate was approximately 30 samples per hour. The Cd-Cu reduction method was applied to the determination of nitrate and the simultaneous determination of nitrate and nitrite in meat products, vegetables, urine, and a water sample. (orig.)

  6. Injection moulded microneedle sensor for real-time wireless pH monitoring.

    Science.gov (United States)

    Mirza, Khalid B; Zuliani, Claudio; Hou, Benjamin; Ng, Fu Siong; Peters, Nicholas S; Toumazou, Christofer

    2017-07-01

    This paper describes the development of an array of individually addressable pH sensitive microneedles using injection moulding and their integration within a portable device for real-time wireless recording of pH distributions in biological samples. The fabricated microneedles are subjected to gold patterning followed by electrodeposition of iridium oxide to sensitize them to 0.07 units of pH change. Miniaturised electronics suitable for the sensors readout, analog-to-digital conversion and wireless transmission of the potentiometric data are embodied within the device, enabling it to measure real-time pH of soft biological samples such as muscles. In this paper, real-time recording of the cardiac pH distribution, during ischemia followed by reperfusion cycles in cardiac muscles of male Wistar rats has been demonstrated by using the microneedle array.

  7. A computer controlled potentiometric titrator for quantitative determination of uranium

    International Nuclear Information System (INIS)

    Verdingh, V.; Michiels, A.

    1988-01-01

    The modified Davies and Gray methods is frequently used for the potentiometric titration of uranium. It is based upon the reduction of U(VI) to U(IV) with a reductant (e.g. Fe ++ ) followed by a selective oxidation of the excess of reductant and subsequent titration of U(IV) with potassium dichromate (K 2 Cr 2 O 7 ). Interference from other elements is low, but the method is rather cumbersome due to the number of reactants to be added before the titration is started. The timing of these additions also plays a role. In order to render the titration less dependent on human factors and with the aim of reaching high reproducibility, a computer controlled system has been designed and set-up. Reagents are added by five computer controlled burettes. A program allows the choice of volumes and waiting times, and commands the start of the final titration which is followed by the microprocessor of the automatic potentiometric titrator. In this way a routine uranium titration can be completed in about twelve minutes. Reproducibilities of the order of ±15% are achievable in routine operation. For high precision work, the titrator is used as an end-point detector. Titrant is added manually by mass, so as to react with > 99% of the uranium. The residual uranium is then titrated automatically by colume with diluted titrant. The precision can be improved by a factor of approximately ten. (orig.)

  8. The Difference Between the Potentiometric Surfaces of the Magothy Aquifer in Southern Maryland, September 1975 and September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the change in the potentiometric surface of the Magothy aquifer in the Magothy Formation of Late Cretaceous age in Southern Maryland between September 1975 and September 2009. The map, based on water level differences obtained from 48 wells, shows that during the 34-year period, the potentiometric surface had little change at the outcrop area, which is in the northernmost part of the study area, but declined 75 feet at Waldorf. Waldorf is located near the southwesternmost part of the study area, and approaches the downdip boundary of the aquifer. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  9. Potentiometric titration of molybdenum (6) with a cathode-polarized solid electrode

    International Nuclear Information System (INIS)

    Boeva, L.V.; Kimstach, V.A.; Bagdasarov, K.N.

    1980-01-01

    The possibility has been studied of using solid electrodes for potentiometric precipitation titration of molybdenum (6). A cathode-polarized electrode, electrochemically covered with a molybdenum blue layer, can be used as indicator electrode. The best results were obtained during deposition of molybdenum blue on a tungsten electrode. The mechanism of electrode work during titration has been investigated. A procedure has been developed of titration of molybdenum (6) in acid solutions using hydroxylamine N-aryl derivatives as titrants

  10. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements.

    Science.gov (United States)

    Orton, Daniel J; Tfaily, Malak M; Moore, Ronald J; LaMarche, Brian L; Zheng, Xueyun; Fillmore, Thomas L; Chu, Rosalie K; Weitz, Karl K; Monroe, Matthew E; Kelly, Ryan T; Smith, Richard D; Baker, Erin S

    2018-01-02

    To better understand disease conditions and environmental perturbations, multiomic studies combining proteomic, lipidomic, and metabolomic analyses are vastly increasing in popularity. In a multiomic study, a single sample is typically extracted in multiple ways, and various analyses are performed using different instruments, most often based upon mass spectrometry (MS). Thus, one sample becomes many measurements, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injections. While some FIA systems have been created to address these challenges, many have limitations such as costly consumables, low pressure capabilities, limited pressure monitoring, and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at a range of flow rates (∼50 nL/min to 500 μL/min) to accommodate both low- and high-flow MS ionization sources. This system also functions at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system, and results showed a highly robust and reproducible platform capable of providing consistent performance over many days without carryover, as long as washing buffers specific to each molecular analysis were utilized.

  11. Flow injection kinetic spectrofluorimetric determination of trace amounts of osmium

    Science.gov (United States)

    Tang, Bo; Zhang, Hui; Wang, Yan

    2005-07-01

    A flow injection (FI) kinetic spectrofluorimetric method is described for the determination of osmium(IV) and the possible mechanism of catalytic reaction is discussed. The method is based on the fluorescence enhancing reaction of o-vanillin furfuralhydrazone (OVFH) with potassium bromate, which is catalyzed by Os(IV) in water medium at pH 6.10 and 45 °C. OVFH is newly synthesized and its ionization, IR and elemental analysis are established. Under these experimental conditions, the oxidized product of OVFH has excitation and emission maxima at 337 and 490 nm, respectively. The linear range of this method is 0-600 ng ml -1 with the R.S.D. of 1.2%. The detection limit is 1.0 ng ml -1 of Os(IV). A high analysis rate of 24 samples h -1 is obtained by the FI method. The proposed method is applied successfully to determine Os(IV) in synthetic mixture and mineral samples, and the results are well consistent with the standard values.

  12. DIFFERENTIATION OF AURANTII FRUCTUS IMMATURUS AND FRUCTUS PONICIRI TRIFOLIATAE IMMATURUS BY FLOW-INJECTION WITH ULTRAVIOLET SPECTROSCOPIC DETECTION AND PROTON NUCLEAR MAGNETIC RESONANCE USING PARTIAL LEAST-SQUARES DISCRIMINANT ANALYSIS.

    Science.gov (United States)

    Zhang, Mengliang; Zhao, Yang; Harrington, Peter de B; Chen, Pei

    2016-03-01

    Two simple fingerprinting methods, flow-injection coupled to ultraviolet spectroscopy and proton nuclear magnetic resonance, were used for discriminating between Aurantii fructus immaturus and Fructus poniciri trifoliatae immaturus . Both methods were combined with partial least-squares discriminant analysis. In the flow-injection method, four data representations were evaluated: total ultraviolet absorbance chromatograms, averaged ultraviolet spectra, absorbance at 193, 205, 225, and 283 nm, and absorbance at 225 and 283 nm. Prediction rates of 100% were achieved for all data representations by partial least-squares discriminant analysis using leave-one-sample-out cross-validation. The prediction rate for the proton nuclear magnetic resonance data by partial least-squares discriminant analysis with leave-one-sample-out cross-validation was also 100%. A new validation set of data was collected by flow-injection with ultraviolet spectroscopic detection two weeks later and predicted by partial least-squares discriminant analysis models constructed by the initial data representations with no parameter changes. The classification rates were 95% with the total ultraviolet absorbance chromatograms datasets and 100% with the other three datasets. Flow-injection with ultraviolet detection and proton nuclear magnetic resonance are simple, high throughput, and low-cost methods for discrimination studies.

  13. Pellet ablation and cloud flow characteristics in the JIPP T-IIU plasma with the injection-angle controllable system

    International Nuclear Information System (INIS)

    Sakakita, H.; Sato, K.N.; Liang, R.; Hamada, Y.; Ando, A.; Kano, Y.; Sakamoto, M.

    1994-01-01

    Pellet ablation and flow characteristics of ablation cloud have been studied in the JIPP T-IIU plasma by using an injection-angle controllable system. A new technique for an ice pellet injection system with controllability of injection angle has been developed and installed to the JIPP T-IIU tokamak in order to vary deposition profile of ice pellets within a plasma. Injection angle can be varied easily and successfully during an interval of two plasma shots in the course of an experiment, so that one can carry out various basic experiments by varying the pellet deposition profile. The injection angle has been varied poloidally from -6 to 6 degree by changing the angle of the last stage drift tube. This situation makes possible for pellets to aim at from about r = -2a/3 to r = 2a/3 of the plasma. From two dimensional observations by CCD cameras, details of the pellet ablation structures with various injection angles have been studied, and a couple of interesting phenomena have been found. In the case of an injection angle (θ) larger than a certain value (θ ≥ 4 o ), a pellet penetrates straightly through the plasma with a trace of straight ablation cloud, which has been expected from usual theoretical consideration. On the other hand, a long helical tail of ablation light has been observed in the case of the angle smaller than the certain value (θ ≤ 4 o ). (author) 4 refs., 4 figs

  14. Stability constants of some Y(III)-complexes from potentiometric data

    Energy Technology Data Exchange (ETDEWEB)

    Pande, S P; Munshi, K N [Nagpur Univ. (India). Dept. of Chemistry

    1975-06-01

    Potentiometric studies have been carried out on the metal complexes of yttrium(III) with 5-sulphosalicylic acid 3,5-dinitro salicylic acid sodium 2,3-dihydroxynaphthalene-6-sulfonate, and nitroso-R-salt. The Calvin-Bjerrum pH-titration technique, as used by Iriving and Rossotti, has been applied to determine the stepwise protonation constants of the ligands and the formation constants of the complexes. The log K values have been computed by alternative methods, at three different temperatures at an ionic strength of 0.2M(NaClO/sub 4/).(author).

  15. A comparison of continuous pneumatic nebulization and flow injection-direct injection nebulization for sample introduction in inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Crain, J.S.; Kiely, J.T.

    1995-08-01

    Dilute nitric acid blanks and solutions containing Ni, Cd, Pb, and U (including two laboratory waste samples) were analyzed eighteen times over a two-month period using inductively coupled plasma-mass spectrometry (ICP-MS). Two different sample introduction techniques were employed: flow injection-direct injection nebulization (FI-DIN) and continuous pneumatic nebulization (CPN). Using comparable instrumental measurement procedures, FI-DIN analyses were 33% faster and generated 52% less waste than CPN analyses. Instrumental limits of detection obtained with FI-DIN and CPN were comparable but not equivalent (except in the case of Pb) because of nebulizer-related differences in sensitivity (i.e., signal per unit analyte concentration) and background. Substantial and statistically significant differences were found between FI-DIN and CPN Ni determinations, and in the case of the laboratory waste samples, there were also small but statistically significant differences between Cd determinations. These small (2 to 3%) differences were not related to polyatomic ion interference (e.g., 95 Mo 16 O + ), but in light of the time savings and waste reduction to be realized, they should not preclude the use of FI-DIN in place of CPN for determination of Cd, Pb, U and chemically

  16. Numerical investigation on the effect of injection pressure on the internal flow characteristics for diethyl ether, dimethyl ether and diesel fuel injectors using CFD

    Directory of Open Access Journals (Sweden)

    Vijayakumar Thulasi

    2011-01-01

    Full Text Available The spray characteristics of the diesel fuel are greatly affected by the cavitation formed inside the injector due to the high pressure differential across the nozzle. Many researchers across the globe are exploring the potential of using diethyl ether and dimethyl ether as an alternate for diesel fuel to meet the strict emission norms. Due to the variation in the fuel properties the internal flow characteristics in injectors for ether fuels are expected to be different from that of the diesel fuel. In this paper computational technique is used to study and compare the internal flow characteristics of diethyl ether, dimethyl ether and diesel fuel. The two phase flow model considering the fuel as a mixture of liquid and vapor is adopted for the simulation study. The injection pressure is varied from 100 to 400 bar and the flow characteristics of all three fuels are simulated and compared. Results indicate that all three fuels have distinct cavitating patterns owing to different property values. The dimethyl ether is found to be more cavitating than diesel and diethyl ether fuels as expected. The mass of fuel injected are found to be decreasing for the ether fuels when compared with diesel fuel at all injection pressures.

  17. Flow-Injection Amperometric Determination of Tacrine based on Ion Transfer across a Water–Plasticized Polymeric Membrane Interface

    Directory of Open Access Journals (Sweden)

    C. Rueda

    2007-07-01

    Full Text Available A flow-injection pulse amperometric method for determining tacrine, based onion transfer across a plasticized poly(vinyl chloride (PVC membrane, was developed. Afour-electrode potentiostat with ohmic drop compensation was used, while a flow-throughcell incorporated the four electrodes and the membrane, which containedtetrabutylammonium tetraphenylborate. The influence of the applied potential and of theflow-injection variables on the determination of tacrine was studied. In the selectedconditions, a linear relationship between peak height and tacrine concentration was foundup to 4x10-5M tacrine. The detection limit was 1x10-7M. Good repeatability was obtained.Some common ions and pharmaceutical excipients did not interfere.

  18. A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mohammad Nooredeen; Hend Samy Amer [National Research Centre, Cairo (Egypt)

    2013-04-15

    A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from 3 Χ 10{sup -7} to 1 Χ 10{sup -2} M and a lower detection limit (LDL) of 1 Χ 10{sup -7} M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

  19. Remote calorimetric detection of urea via flow injection analysis.

    Science.gov (United States)

    Gaddes, David E; Demirel, Melik C; Reeves, W Brian; Tadigadapa, Srinivas

    2015-12-07

    The design and development of a calorimetric biosensing system enabling relatively high throughput sample analysis are reported. The calorimetric biosensor system consists of a thin (∼20 μm) micromachined Y-cut quartz crystal resonator (QCR) as a temperature sensor placed in close proximity to a fluidic chamber packed with an immobilized enzyme. Layer by layer enzyme immobilization of urease is demonstrated and its activity as a function of the number of layers, pH, and time has been evaluated. This configuration enables a sensing system where a transducer element is physically separated from the analyte solution of interest and is thereby free from fouling effects typically associated with biochemical reactions occuring on the sensor surface. The performance of this biosensing system is demonstrated by detection of 1-200 mM urea in phosphate buffer via a flow injection analysis (FIA) technique. Miniaturized fluidic systems were used to provide continuous flow through a reaction column. Under this configuration the biosensor has an ultimate resolution of less than 1 mM urea and showed a linear response between 0-50 mM. This work demonstrates a sensing modality in which the sensor itself is not fouled or contaminated by the solution of interest and the enzyme immobilized Kapton® fluidic reaction column can be used as a disposable cartridge. Such a system enables reuse and reliability for long term sampling measurements. Based on this concept a biosensing system is envisioned which can perform rapid measurements to detect biomarkers such as glucose, creatinine, cholesterol, urea and lactate in urine and blood continuously over extended periods of time.

  20. Potentiometric urea biosensor based on an immobilised fullerene-urease bio-conjugate.

    Science.gov (United States)

    Saeedfar, Kasra; Heng, Lee Yook; Ling, Tan Ling; Rezayi, Majid

    2013-12-06

    A novel method for the rapid modification of fullerene for subsequent enzyme attachment to create a potentiometric biosensor is presented. Urease was immobilized onto the modified fullerene nanomaterial. The modified fullerene-immobilized urease (C60-urease) bioconjugate has been confirmed to catalyze the hydrolysis of urea in solution. The biomaterial was then deposited on a screen-printed electrode containing a non-plasticized poly(n-butyl acrylate) (PnBA) membrane entrapped with a hydrogen ionophore. This pH-selective membrane is intended to function as a potentiometric urea biosensor with the deposition of C60-urease on the PnBA membrane. Various parameters for fullerene modification and urease immobilization were investigated. The optimal pH and concentration of the phosphate buffer for the urea biosensor were 7.0 and 0.5 mM, respectively. The linear response range of the biosensor was from 2.31 × 10-3 M to 8.28 × 10-5 M. The biosensor's sensitivity was 59.67 ± 0.91 mV/decade, which is close to the theoretical value. Common cations such as Na+, K+, Ca2+, Mg2+ and NH4+ showed no obvious interference with the urea biosensor's response. The use of a fullerene-urease bio-conjugate and an acrylic membrane with good adhesion prevented the leaching of urease enzyme and thus increased the stability of the urea biosensor for up to 140 days.

  1. Determination of uranium and plutonium by sequential potentiometric titration

    International Nuclear Information System (INIS)

    Kato, Yoshiharu; Takahashi, Masao

    1976-01-01

    The determination of uranium and plutonium in mixed oxide fuels has been developed by sequential potentiometric titration. A weighed sample of uranium and plutonium oxides is dissolved in a mixture of nitric and hydrofluoric acids and the solution is fumed with sulfuric acid. After the reduction of uranium and plutonium to uranium(IV) and plutonium(III) by chromium(II) sulfate, 5 ml of buffer solution (KCl-HCl, pH 1.0) is added to the solution. Then the solution is diluted to 30 ml with water and the pH of the solution is adjusted to 1.0 -- 1.5 with 1 M sodium hydroxide. The solution is stirred until the oxidation of the excess of chromium(II) by air is completed. After the removal of dissolved oxygen by bubbling nitrogen through the solution for 10 minutes, uranium (IV) is titrated with 0.1 N cerium(IV) sulfate. Then, plutonium is titrated by 0.02 N cerium(IV) sulfate. When a mixture of uranium and plutonium is titrated with 0.1 N potassium dichromate potentiometrically, the potential change at the end point of plutonium is very small and the end point of uranium is also unclear when 0.1 N potassium permanganate is used as a titrant. In the present method, nitrate, fluoride and copper(II) interfere with the determination of plutonium and uranium. Iron interferes quantitatively with the determination of plutonium but not of uranium. Results obtained in applying the proposed method to 50 mg of mixtures of plutonium and uranium ((7.5 -- 50))% Pu were accurate to within 0.15 mg of each element. (auth.)

  2. Preliminary study on functional performance of compound type multistage safety injection tank

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo

    2015-01-01

    Highlights: • Functional performance of compound type multistage safety injection tanks is studied. • Effects of key design parameters are scrutinized. • Distinctive flow features in compound type safety injection tanks are explored. - Abstract: A parametric study is carried out to evaluate the functional performance of a compound type multistage safety injection tank that would be considered one of the components for the passive safety injection systems in nuclear power plants. The effects of key design parameters such as the initial volume fraction and charging pressure of gas, tank elevation, vertical location of a sparger, resistance coefficient, and operating condition on the injection flow rate are scrutinized along with a discussion of the relevant flow features. The obtained results indicate that the compound type multistage safety injection tank can effectively control the injection flow rate in a passive manner, by switching the driving force for the safety injection from gas pressure to gravity during the refill and reflood phases, respectively

  3. Autologous Pure Platelet-Rich Plasma Dermal Injections for Facial Skin Rejuvenation: Clinical, Instrumental, and Flow Cytometry Assessment.

    Science.gov (United States)

    Cameli, Norma; Mariano, Maria; Cordone, Iole; Abril, Elva; Masi, Serena; Foddai, Maria Laura

    2017-06-01

    Platelet-rich plasma (PRP) is an emerging treatment in dermatology recently proposed for skin rejuvenation. To evaluate the efficacy and safety of autologous pure PRP dermal injections on facial skin rejuvenation, investigating the cellularity of PRP samples. Twelve patients underwent 3 sessions of PRP injection at 1-month intervals. The clinical and instrumental outcomes were evaluated before (T0) and 1 month (T1) after the end of treatment by means of transepidermal water loss, corneometry, Cutometer, Visioscan, and Visioface. A flow cytometry characterization on PRP and peripheral blood (PB) samples was performed. Clinical and patient evaluation showed improvement of skin texture. Skin gross elasticity, skin smoothness parameters, skin barrier function, and capacitance were significantly improved. No difference between PRP and PB lymphocyte immunological asset was observed. A leukocyte population (mainly CD3) and neutrophils depletion were documented in all the PRP samples. This instrumental study demonstrated that PRP poor in leukocytes can provide objective improvements in skin biostimulation. Flow cytometry showed no variability among the PRP samples using a reproducible separation system and a low content in proinflammatory cells. Although a pilot study, it may be helpful for future investigations on PRP cellularity.

  4. Potentiometric urea biosensor based on multi-walled carbon nanotubes (MWCNTs)/silica composite material

    International Nuclear Information System (INIS)

    Ahuja, Tarushee; Kumar, D.; Singh, Nahar; Biradar, A.M.; Rajesh

    2011-01-01

    A novel potentiometric urea biosensor has been fabricated with urease (Urs) immobilized multi-walled carbon nanotubes (MWCNTs) embedded in silica matrix deposited on the surface of indium tin oxide (ITO) coated glass plate. The enzyme Urs was covalently linked with the exposed free -COOH groups of functionalized MWCNTs (F-MWCNTs), which are subsequently incorporated within the silica matrix by sol-gel method. The Urs/MWCNTs/SiO 2 /ITO composite modified electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, thermal gravimetric analysis (TGA) and UV-visible spectroscopy. The morphologies and electrochemical performance of the modified Urs/MWCNTs/SiO 2 /ITO electrode have been investigated by scanning electron microscopy (SEM) and potentiometric method, respectively. The synergistic effect of silica matrix, F-MWCNTs and biocompatibility of Urs/MWCNTs/SiO 2 made the biosensor to have the excellent electro catalytic activity and high stability. The resulting biosensor exhibits a good response performance to urea detection with a wide linear range from 2.18 x 10 -5 to 1.07 x 10 -3 M urea. The biosensor shows a short response time of 10-25 s and a high sensitivity of 23 mV/decade/cm 2 .

  5. Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

    International Nuclear Information System (INIS)

    Yaqoob, M.; Nabi, A.

    2013-01-01

    A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 - 1000 micro g N L /sup -1/ (R2 = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 micro g N L and relative standard deviations (n = 10) of 0.9 and 1.2% for 50 micro g N L nitrite and nitrate respectively. The sample throughput was 50 h. The effect of reagent concentrations, physical parameters (flow rate, sample volume, reaction coil and copperised cadmium column length) and the potential interferences are reported. The effect of salinity on the blank and on the determination of nitrite and nitrate are also presented. The method was applied to natural waters (rainwater, freshwater and estuarine water) and the results for nitrite + nitrate (140 - 7310 micro g N L/sup -1/) were not significantly different (95% confidence interval) from results obtained using a segmented flow analyser reference method with spectrophotometric detection. (author)

  6. Control of Surge in Centrifugal Compressor by Using a Nozzle Injection System: Universality in Optimal Position of Injection Nozzle

    Directory of Open Access Journals (Sweden)

    Toshiyuki Hirano

    2012-01-01

    Full Text Available The passive control method for surge and rotating stall in centrifugal compressors by using a nozzle injection system was proposed to extend the stable operating range to the low flow rate. A part of the flow at the scroll outlet of a compressor was recirculated to an injection nozzle installed on the inner wall of the suction pipe of the compressor through the bypass pipe and injected to the impeller inlet. Two types of compressors were tested at the rotational speeds of 50,000 rpm and 60,000 rpm with the parameter of the circumferential position of the injection nozzle. The present experimental results revealed that the optimum circumferential position, which most effectively reduced the flow rate for the surge inception, existed at the opposite side of the tongue of the scroll against the rotational axis and did not depend on the compressor system and the rotational speeds.

  7. Transition from annular flow to plug/slug flow in condensation of steam in microchannels

    Energy Technology Data Exchange (ETDEWEB)

    Quan, Xiaojun; Cheng, Ping; Wu, Huiying [School of Mechanical and Power Engineering, Shanghai Jiaotong University, 800 Dong Chuan Road, Shanghai 200240 (China)

    2008-02-15

    A visualization study has been conducted to investigate the transition from annular flow to plug/slug flow in the condensation of steam in two different sets of parallel microchannels, having hydraulic diameters of 90 {mu}m and 136 {mu}m, respectively. The steam in the parallel microchannels was cooled on the bottom by forced convection of water and by natural convection of air from the top. It is found that the location, where the transition from annular flow to plug/slug flow takes place, depends on mass flux and cooling rate of steam. The effects of mass flux and cooling rate on the occurrence frequency of the injection flow in a single microchannel, having a hydraulic diameter of 120 {mu}m and 128 {mu}m, respectively, are investigated. It is found that two different shapes of injection flow occur in the smooth annular flow in microchannels: injection flow with unsteady vapor ligament occurring at low mass flux (or high cooling rate) and injection flow with steady vapor ligament occurring at high mass flux (or low cooling rate). It is also found that increase of steam mass flux, decrease of cooling rate, or decrease of the microchannel diameter tends to enhance instability of the condensate film on the wall, resulting in occurrence of the injection flow further toward the outlet with an increase in occurrence frequency. (author)

  8. Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, May 2006

    Science.gov (United States)

    Ortiz, A.G.

    2007-01-01

    Introduction Hydrologic Conditions in West-Central Florida The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2006. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when ground-water levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 50.23 inches for west-central Florida (from June 2005 through May 2006) was 2.82 inches below the historical cumulative average of 53.05 inches (Southwest Florida Water Management District, 2006). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water

  9. The difference between the potentiometric surfaces of the lower Patapsco aquifer in southern Maryland, September 1990 and September 2007

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2009-01-01

    This report presents a map showing the change in the potentiometric surface of the lower Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland for September 1990 and September 2007. The map, based on water-level measurements in 45 wells, shows that the change of the potentiometric surface during the 17-year period ranged from increases of 19 feet at Indian Head and 6 feet near the outcrop area in Glen Burnie, to declines of 41 feet at Arnold, 45 feet at Severndale, 68 feet at Crofton Meadows, 77 feet at Waldorf, 76 feet at La Plata, 28 feet at the Morgantown power plant, and 35 feet at the Swan Point subdivision south of Morgantown.

  10. Model and simulation for melt flow in micro-injection molding based on the PTT model

    International Nuclear Information System (INIS)

    Cao, Wei; Kong, Lingchao; Li, Qian; Ying, Jin; Shen, Changyu

    2011-01-01

    Unsteady viscoelastic flows were studied using the finite element method in this work. The Phan-Thien–Tanner (PTT) model was used to represent the rheological behavior of viscoelastic fluids. To effectively describe the microscale effects, the slip boundary condition and surface tension were added to the mathematical model for melt flow in micro-injection molding. The new variational equation of pressure, including the viscoelastic parameters and slip boundary condition, was generalized using integration by parts. A computer code based on the finite element method and finite difference method was developed to solve the melt flow problem. Numerical simulation revealed that the melt viscoelasticity plays an important role in the prediction of melt pressure, temperature at the gate and the succeeding melt front advancement in the cavity. Using the viscoelastic model one can also control the rapid increase in simulated pressure, temperature, and reduce the filling difference among different cavities. The short shot experiments of micro-motor shaft showed that the predicted melt front from the viscoelastic model is in fair agreement with the corresponding experimental results

  11. Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors

    Directory of Open Access Journals (Sweden)

    Ching-Hsing Luo

    2011-09-01

    Full Text Available A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC, a microcontroller unit (MCU, a graphical user interface (GUI, and a radio frequency (RF transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA. The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment, a small size of 5.6 cm × 8.7 cm, high portability, and high integration.

  12. Potentiometric studies on some ternary complexes of Nd(III), Sm(III), Gd(III) and Ho(III) with cyclohexanediaminetetraacetic acid as primary ligand

    International Nuclear Information System (INIS)

    Marathe, D.G.; Munshi, K.N.

    1983-01-01

    The formation constants of the ternary complexes of neodymium(III), samarium(III), gadlonium(III) and holmium(III) with cyclohexanediaminetetraacetic acid (CyDTA) as primary ligand and dihydroxynaphthalene (DHN), dihydroxynaphthalene-6-sulphonic acid (DHNSA) and cateechol-3,5-disulphonic acid (CDSA) as secondary ligands have been investigated by potentiometric titration technique. The secondary ligands have been investigated by potentiometric titration technique. The values of formation constants of 1:1:1 ternary chelates are reported at three different temperatures, and at a fixed ionic strength, μ = 0.1 M (NaClO 4 ). (author)

  13. Flow injection chemiluminescent determination of N-nitrosodimethylamine using photogenerated tris(2,2'-bipyridyl) ruthenium (III)

    International Nuclear Information System (INIS)

    Perez-Ruiz, Tomas; Martinez-Lozano, Carmen; Tomas, Virginia; Martin, Jesus

    2005-01-01

    A flow injection configuration was developed and evaluated for the chemiluminescent determination of N-nitrosodimethylamine. The method is based on the on-line cleavage of the N-NO bond of the nitrosamine by irradiation with ultraviolet light. The dimethylamine generated was subsequently reacted with tris(2,2'-bipyridyl) ruthenium (III), which was generated through the on-line photo-oxidation of tris(2,2'-bipyridyl) ruthenium (II) with peroxydisulfate. After selecting the best operating parameters, the emitted light showed a linear relationship with the concentration of N-nitrosodimethylamine between 1.5 and 148 ng ml -1 , with a detection limit of 0.29 ng ml -1 . The repeatability was 1.6% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five consecutive days, was 3.2%. The sample throughput was 50 injections per hour. The method was applied to studying the recoveries of N-nitrosodimethylamine in water and different cured meat products

  14. [Prophylaxis of recurring low-flow priapism : Experimental botulinum neurotoxin injection into the ischiocavernosus muscle].

    Science.gov (United States)

    Reichel, G; Stenner, A

    2018-01-01

    The treatment of recurring low-flow priapism with the usual medications is still unsatisfactory. The case of an otherwise healthy young man experiencing low-flow priapism at the age of 31 is presented. A reason for his condition could not be identified. Over the course of several months, he required emergency urological treatment more than ten times. Treatment with cyproterone acetate (Androcur® 50 mg/day) stopped the spontaneous erections, but resulted in erectile impotence, reduced motivation, decreased interest in sex, weight gain of 10 kg, breast enlargement combined with touch sensitivity on both sides, and hair loss on both legs. In addition, the patient complained about painful cramps in his pelvic muscles. After appropriate explanations he agreed to try botulinum neurotoxin injections into both ischiocavernosus muscles. The objective was to reduce muscle tone in order to improve venous drainage of blood from the penis. The latest relapse of priapism occurred more than 6 months ago.

  15. Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Gammelgaard, Bente

    2001-01-01

    A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor...

  16. Determination of free acid in plutonium (IV) solutions - thermometrically, potentiometrically

    International Nuclear Information System (INIS)

    Williams, T.L.; Tucker, G.M.; Huff, G.A.; Jordan, L.G.

    1981-09-01

    The thermometric titration technique was found to offer certain advantages over potentiometry in the determination of free acid in Pu(IV) solutions. The thermometric technique was applied to the determination of free acid in plutonium nitrate solutions using potassium fluoride to suppress the hydrolytic interference of plutonium(IV). The results indicate that 0.2 to 2.0 milliequivalents of free acid can be determined with acceptable bias and precision in solutions containing up to 30 milligrams of plutonium. In contrast, neither the thermometric nor the potentiometric technique was suitable for samples containing more than eight milligrams of plutonium complexed with potassium oxalate

  17. Carbon dioxide fluid-flow modeling and injectivity calculations

    Science.gov (United States)

    Burke, Lauri

    2011-01-01

    At present, the literature lacks a geologic-based assessment methodology for numerically estimating injectivity, lateral migration, and subsequent long-term containment of supercritical carbon dioxide that has undergone geologic sequestration into subsurface formations. This study provides a method for and quantification of first-order approximations for the time scale of supercritical carbon dioxide lateral migration over a one-kilometer distance through a representative volume of rock. These calculations provide a quantified foundation for estimating injectivity and geologic storage of carbon dioxide.

  18. Flow injection spectrophotometric determination of Fe(III) and V(v)

    International Nuclear Information System (INIS)

    Elrahman, Azza Mohamed

    2000-01-01

    Phenylflourone was synthesized with the objective of developing a method for determining Fe(III) and V(V) in the pressence of micelles using flow injectoin technique. Phenylflourone showed a wavelength of maximum absorption at 412 nm which was not affected by the presence of miccelles i.e. n-hexadodecylpyridinum bromide and sodium n-dodecylsulphate, but they have different effects on the absorbance of PHF. The example of PHF-Fe(III) and PHF-V(V) showed the wavelength of the maximum absorption at 4428 nm and 412 nm, respectively. Presence of micelles shifted the wavelength of the two complexes to a lower one. Generally the addition of micelles increased the absorbance of phenylflourone metal ions complexes except for PHF-V(V) with hexadodecylpyridinum bromide. With flow injection technique two approaches were practiced the use of micelle as a carrier or water as a carrier. Sodium n-dodecylsulphate increased the absorbance of the two complexes when it was used as a carrier or added to the metal ions using water as carrier. On the other hand, the use of n-hexadodecylpyridinum bromide as carrieer increased the absorbance of the complexes but it decreased the absorbance when it was used in conjunction with metal ions and water as a carrier. After establishing the optimum FI conditions for PHF-Fe(III) and PHF-V(V) complexes, the calibration curves were construction and produced semiliner response in the concentration range studied. Ti(IV) III, Mo(VI) showed a positive interference in PHF-Fe(III) and PHF-V(V) complexes, respectively.(Author)

  19. Renal blood flow after selective injection of different dosages of diatrizoate into the renal artery

    International Nuclear Information System (INIS)

    Burgener, F.A.; Fischer, H.W.; Weber, D.A.

    1975-01-01

    The characteristic biphasic renal haemodynamic response to diatrizoate injected into the renal artery was shown in the dog with the 133-xenon washout technique. A brief increase in renal blood flow (RBF) during the first ten seconds is followed by a more prolonged period of diminuished RBF. A dose of 4 ml. diatrizoate 60% resulted in the maximum RBF increase of 43% after ten seconds, but even 1 ml. diatrizoate raised the RBF 24%. The initial vasodilator effect of diatrizoate compares well in its extent with the most potent renal vasodilators. (orig.) [de

  20. Potentiometric Urea Biosensor Based on an Immobilised Fullerene-Urease Bio-Conjugate

    Directory of Open Access Journals (Sweden)

    Kasra Saeedfar

    2013-12-01

    Full Text Available A novel method for the rapid modification of fullerene for subsequent enzyme attachment to create a potentiometric biosensor is presented. Urease was immobilized onto the modified fullerene nanomaterial. The modified fullerene-immobilized urease (C60-urease bioconjugate has been confirmed to catalyze the hydrolysis of urea in solution. The biomaterial was then deposited on a screen-printed electrode containing a non-plasticized poly(n-butyl acrylate (PnBA membrane entrapped with a hydrogen ionophore. This pH-selective membrane is intended to function as a potentiometric urea biosensor with the deposition of C60-urease on the PnBA membrane. Various parameters for fullerene modification and urease immobilization were investigated. The optimal pH and concentration of the phosphate buffer for the urea biosensor were 7.0 and 0.5 mM, respectively. The linear response range of the biosensor was from 2.31 × 10−3 M to 8.28 × 10−5 M. The biosensor’s sensitivity was 59.67 ± 0.91 mV/decade, which is close to the theoretical value. Common cations such as Na+, K+, Ca2+, Mg2+ and NH4+ showed no obvious interference with the urea biosensor’s response. The use of a fullerene-urease bio-conjugate and an acrylic membrane with good adhesion prevented the leaching of urease enzyme and thus increased the stability of the urea biosensor for up to 140 days.

  1. Potentiometric Zinc Ion Sensor Based on Honeycomb-Like NiO Nanostructures

    Directory of Open Access Journals (Sweden)

    Magnus Willander

    2012-11-01

    Full Text Available In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM, high resolution transmission electron microscopy (HRTEM and X-ray diffraction (XRD techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase. In addition to this, the NiO nanostructures were used in the development of a zinc ion sensor electrode by functionalization with the highly selective zinc ion ionophore 12-crown-4. The developed zinc ion sensor electrode has shown a good linear potentiometric response for a wide range of zinc ion concentrations, ranging from 0.001 mM to 100 mM, with sensitivity of 36 mV/decade. The detection limit of the present zinc ion sensor was found to be 0.0005 mM and it also displays a fast response time of less than 10 s. The proposed zinc ion sensor electrode has also shown good reproducibility, repeatability, storage stability and selectivity. The zinc ion sensor based on the functionalized NiO nanostructures was also used as indicator electrode in potentiometric titrations and it has demonstrated an acceptable stoichiometric relationship for the determination of zinc ion in unknown samples. The NiO nanostructures-based zinc ion sensor has potential for analysing zinc ion in various industrial, clinical and other real samples.

  2. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    International Nuclear Information System (INIS)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D.; Chmurzynski, L.

    2008-01-01

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement

  3. Difference between the potentiometric surfaces of the Lower Patapsco aquifer in southern Maryland, September 1990 and September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the change in the potentiometric surface of the lower Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland between September 1990 and September 2009. The map, based on water level differences obtained from 45 wells, shows that the change of the potentiometric surface during the 19-year period ranged from increases of 25 feet at Indian Head and 4 feet near the outcrop area in Glen Burnie, to declines of 35 feet at Arnold, 56 feet at Severndale, 28 feet at Crofton Meadows, 73 feet at Waldorf, 79 feet near La Plata, 35 feet at the Morgantown power plant, and 32 feet at Swan Point. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  4. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland); Chmurzynski, L. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland)], E-mail: lech@chem.univ.gda.pl

    2008-08-15

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.

  5. Statistical evaluation of an interlaboratory comparison for the determination of uranium by potentiometric titration

    International Nuclear Information System (INIS)

    Ketema, D.J.; Harry, R.J.S.; Zijp, W.L.

    1990-09-01

    Upon request of the ESARDA working group 'Low enriched uranium conversion - and fuel fabrication plants' an interlaboratory comparison was organized, to assess the precision and accuracy concerning the determination of uranium by the potentiometric titration method. This report presents the results of a statistical evaluation on the data of the first phase of this exercise. (author). 9 refs.; 5 figs.; 24 tabs

  6. Small-volume potentiometric titrations: EPR investigations of Fe-S cluster N2 in mitochondrial complex I.

    Science.gov (United States)

    Wright, John J; Salvadori, Enrico; Bridges, Hannah R; Hirst, Judy; Roessler, Maxie M

    2016-09-01

    EPR-based potentiometric titrations are a well-established method for determining the reduction potentials of cofactors in large and complex proteins with at least one EPR-active state. However, such titrations require large amounts of protein. Here, we report a new method that requires an order of magnitude less protein than previously described methods, and that provides EPR samples suitable for measurements at both X- and Q-band microwave frequencies. We demonstrate our method by determining the reduction potential of the terminal [4Fe-4S] cluster (N2) in the intramolecular electron-transfer relay in mammalian respiratory complex I. The value determined by our method, E m7 =-158mV, is precise, reproducible, and consistent with previously reported values. Our small-volume potentiometric titration method will facilitate detailed investigations of EPR-active centres in non-abundant and refractory proteins that can only be prepared in small quantities. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Potentiometric end point detection in the EDTA titrimetric determination of gallium

    International Nuclear Information System (INIS)

    Gopinath, N.; Renuka, M.; Aggarwal, S.K.

    2001-01-01

    Gallium is titrated in presence of known amount of Fe (III) with EDTA in HNO 3 solution at pH 2 to 3. The end point is detected potentiometrically employing a bright platinum wire - saturated calomel (SCE) reference electrode system, the redox couple being Fe (III) / Fe (II). Since Fe (III) is also titrated by EDTA, it is, therefore, subtracted from titre value to get the EDTA equivalent to gallium only. Precision and accuracy 0.2 to 0.4% was obtained in the results of gallium in the range of 8 to 2 mg. (author)

  8. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... position was measured on the polymer μ-parts to evaluate filling behavior of the polymer melt flowing through μ-features. Experimental results obtained under different processing conditions were evaluated to correlate the process parameter levels influence on the selected responses. Results showed...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  9. Investigation the effects of injection pressure and compressibility and nozzle entry in diesel injector nozzle’s flow

    Directory of Open Access Journals (Sweden)

    Seyed mohammadjavad Zeidi

    2015-04-01

    Full Text Available Investigating nozzle’s orifice flow is challenging both experimentally and theoretically. This paper focuses on simulating flow inside diesel injector nozzle via Ansys fluent v15. Validation is performed with experimental results from Winkhofler et al (2001. Several important parameters such as mass flow rate, velocity profiles and pressure profiles are used for this validation. Results include the effects of contraction inside nozzle’s orifice, effect of compressibility; effect of injection pressures and several orifice entries are also simulated in this study. For considering the effect of compressibility a user defined function used in this simulation. Cavitation model which is used in this simulation is Singhal et al. cavitation model. Presto discretization method is used for Pressure equation and second upwind discretization method is used for Momentum equation. Converging Singhal et al. cavitation model is very challenging and it needs several efforts and simulations.

  10. The difference between the potentiometric surfaces of the Upper Patapsco aquifer in southern Maryland, September 1990 and September 2009

    Science.gov (United States)

    Curtin, Stephen E.; Andreasen, David C.; Staley, Andrew W.

    2010-01-01

    This report presents a map showing the change in the potentiometric surface of the upper Patapsco aquifer in the Patapsco Formation of Early Cretaceous age in Southern Maryland between September 1990 and September 2009. The map, based on water level differences obtained from 33 wells, shows that during the 19-year period, the change in the potentiometric surface ranged from zero at the edge of the outcrop area in northern Anne Arundel County to a decline of 20 feet at Broad Creek, 16 feet near Arnold, 32 feet at Waldorf, 37 feet at the Chalk Point power plant, and 43 feet at Lexington Park. The map also shows well yield in gallons per day for 2008 at wells or well fields.

  11. Fabrication of an Amperometric Flow-Injection Microfluidic Biosensor Based on Laccase for In Situ Determination of Phenolic Compounds

    Directory of Open Access Journals (Sweden)

    Juan C. Gonzalez-Rivera

    2015-01-01

    Full Text Available We aim to develop an in situ microfluidic biosensor based on laccase from Trametes pubescens with flow-injection and amperometry as the transducer method. The enzyme was directly immobilized by potential step chronoamperometry, and the immobilization was studied using cyclic voltammetry and electrochemical impedance spectroscopy. The electrode response by amperometry was probed using ABTS and syringaldazine. A shift of interfacial electron transfer resistance and the electron transfer rate constant from 18.1 kΩ to 3.9 MΩ and 4.6 × 10−2 cm s−1 to 2.1 × 10−4 cm s−1, respectively, evidenced that laccase was immobilized on the electrode by the proposed method. We established the optimum operating conditions of temperature (55°C, pH (4.5, injection flow rate (200 µL min−1, and applied potential (0.4 V. Finally, the microfluidic biosensor showed better lower limit of detection (0.149 µM and sensitivity (0.2341 nA µM−1 for ABTS than previous laccase-based biosensors and the in situ operation capacity.

  12. PVC-membrane potentiometric sensors based on a recently synthesized Schiff base for Fe(III ion

    Directory of Open Access Journals (Sweden)

    S. Yousef Ebrahimipur

    2012-12-01

    Full Text Available A potentiometric iron sensor based on the use 3-(2-diethylamino-ethylimino-1,3-dihydro-indol-2-one (DEDIO as an ionophore in poly(vinyl chloride (PVC matrix, is reported. The plasticized membrane sensor exhibits a Nernstian response for Fe(III ions over a wide concentration range (2.0 × 10-6 - 5.0 × 10-2 M with a super Nernstian slope of 26(plus or minus 1 mV per decade. It has a fast response time of less than 12 s and can be used for ten weeks without any considerable divergences in its potentials the electrode can be used in the pH range 4.5-8.0. The proposed sensor shows fairly good discriminating ability towards Fe(III ion in comparison with a large number of alkali, alkaline earth, transition and heavy metal ions. The sensor was used as indicator electrode in potentiometric titration of Fe(III ions vs. EDTA.DOI: http://dx.doi.org/10.4314/bcse.v26i1.7

  13. Flow injection analysis of sulphide based on its photoelectrocatalytic oxidation at poly-methylene blue modified glassy carbon electrode

    International Nuclear Information System (INIS)

    Dilgin, Yusuf; Canarslan, Seda; Ayyildiz, Onder; Ertek, Bensu; Nişli, Gürel

    2012-01-01

    A new approach for photoelectrocatalytic determination of sulphide in a flow injection analysis (FIA) system was studied using a poly-methylene blue modified glassy carbon electrode (poly-MB/GCE). Results from electrochemical measurements have revealed that poly-MB/GCE is capable of signalling electrocatalytic and photoelectrocatalytic activity towards sulphide oxidation. When the surface of poly-MB/GCE was irradiated with a light source (250 W Halogen lamp), the electrocatalytic current increased substantially. A homemade flow electrochemical cell with a suitable transparent window for the irradiation of the electrode surface was used to perform the photoelectrocatalytic determination of sulphide in FIA system. The currents obtained from the photoamperometric measurements in the FIA system at optimum conditions (carrier solution: pH 9.0 Britton Robinson buffer solution containing 0.1 M KCl; flow rate: 1.3 mL min −1 ; transmission tubing length: 10 cm; injection volume: 100 μL; and constant applied potential: +150 mV vs. Ag/AgCl/KCl sat ) were linearly correlated with the sulphide concentration. The calibration curves were obtained for sulphide concentrations in a range of 0.5–500 μM. The detection limits were found to be 0.27 and 0.15 μM for amperometric and photoamperometric methods, respectively. The proposed method was successfully applied to different wastewaters such as municipal sewage or tannery wastewater. Finally, results from the sulphide measurements by poly-MB/GCE were in good agreement with those attained using spectrophotometric method.

  14. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine

    International Nuclear Information System (INIS)

    Nery, Emilia Witkowska; Kubota, Lauro T.

    2016-01-01

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca"2"+/Mg"2"+, K"+/Na"+) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only describes new

  15. Integrated, paper-based potentiometric electronic tongue for the analysis of beer and wine

    Energy Technology Data Exchange (ETDEWEB)

    Nery, Emilia Witkowska, E-mail: ewitkowskanery@ichf.edu.pl [Department of Analytical Chemistry, Institute of Chemistry – UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); National Institute of Science and Technology in Bioanalytics, Institute of Chemistry – UNICAMP, P.O. Box 6154, Campinas (Brazil); Kubota, Lauro T. [Department of Analytical Chemistry, Institute of Chemistry – UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); National Institute of Science and Technology in Bioanalytics, Institute of Chemistry – UNICAMP, P.O. Box 6154, Campinas (Brazil)

    2016-04-28

    The following manuscript details the stages of construction of a novel paper-based electronic tongue with an integrated Ag/AgCl reference, which can operate using a minimal amount of sample (40 μL). First, we optimized the fabrication procedure of silver electrodes, testing a set of different methodologies (electroless plating, use of silver nanoparticles and commercial silver paints). Later a novel, integrated electronic tongue system was assembled with the use of readily available materials such as paper, wax, lamination sheets, bleach etc. New system was thoroughly characterized and the ion-selective potentiometric sensors presented performance close to theoretical. An electronic tongue, composed of electrodes sensitive to sodium, calcium, ammonia and a cross-sensitive, anion-selective electrode was used to analyze 34 beer samples (12 types, 19 brands). This system was able to discriminate beers from different brands, and types, indicate presence of stabilizers and antioxidants, dyes or even unmalted cereals and carbohydrates added to the fermentation wort. Samples could be classified by type of fermentation (low, high) and system was able to predict pH and in part also alcohol content of tested beers. In the next step sample volume was minimalized by the use of paper sample pads and measurement in flow conditions. In order to test the impact of this advancement a four electrode system, with cross-sensitive (anion-selective, cation-selective, Ca{sup 2+}/Mg{sup 2+}, K{sup +}/Na{sup +}) electrodes was applied for the analysis of 11 types of wine (4 types of grapes, red/white, 3 countries). Proposed matrix was able to group wines produced from different varieties of grapes (Chardonnay, Americanas, Malbec, Merlot) using only 40 μL of sample. Apart from that, storage stability studies were performed using a multimeter, therefore showing that not only fabrication but also detection can be accomplished by means of off-the-shelf components. This manuscript not only

  16. Determination of uranium in organic phase by flow injection spectrophotometric analysis

    International Nuclear Information System (INIS)

    Yu Yiyun

    1998-01-01

    Based on the use of merging zone circuit and simulating a series of standard solution of uranium in organic phase, uranium in unknown organic phase sample was determined by flow injection spectrophotometry. A linear calibration graph was obtained with correlation coefficient of 0.999 for uranium concentration in organic phase over 10∼200 mg/L. Isopropyl alcohol was used as carrier solution. Mixing colour solution contains isopropyl alcohol, triethanolamine, masking reagent and Br-PADAP. The relative standard deviation of the method was better than +-5%. Determination of each sample can be completed in one minute. The method characteristic is: (1) using merging zone and simulating standard solution of uranium in organic phase, the method is sensitive and reliable; (2) even if the determined solution was in turbid condition, it can be quantitatively determined; (3) by means of solution replace technique, the tube of peristaltic pump can be used over a long period of time

  17. Flow-injection determination of thorium and uranium after on-line ion-exchange preconcentration in Dowex 50-X8

    International Nuclear Information System (INIS)

    Perez Pavon, J.L.; Garcia Pinto, C.G.; Rodriguez Garcia, Estrella; Moreno Cordero, Bernardo

    1992-01-01

    The preconcentration of thorium and uranium on Dowex 50-X8 was studied as a method for the preconcentration of these cations prior to their determination by flow injection with spectrophotometric detection using Arsenazo III in 3.6 M HCl stabilized with Triton X-100 as chromogenic reagent. The preconcentration device is a minicolumn included in the sample loop of the injection valve. A second valve contains a reducing minicolumn filled with lead powder to reduce U(VI) to U(IV) before the confluence of the sample with the reagent stream. The method can be applied to samples containing 0.5-100 μg l -1 and was tested with different spiked water samples. (author). 15 refs.; 3 figs.; 3 tabs

  18. A potentiometric study of (acid+base) equilibria in substituted 4-nitropyridine N-oxide systems in methanol and dimethyl sulfoxide

    International Nuclear Information System (INIS)

    Gurzynski, Lukasz; Puszko, Aniela; Makowski, Mariusz; Chmurzynski, Lech

    2007-01-01

    The acid dissociation constants for cationic acids conjugated with 4-nitropyridine N-oxides have been determined using potentiometric titration method. The measurements in the systems of thirteen 4-nitropyridine N-oxide derivatives were carried out in the polar amphiprotic methanol (MeOH) and in the aprotic protophilic dimethyl sulfoxide (DMSO). Likewise as in the polar aprotic protophobic solvents (acetonitrile, acetone) it was found that in MeOH for all N-oxides studied the pK a values were readily determinable, whereas in DMSO the pK a values were hardly determinable or indeterminable by using the potentiometric method. In addition, just like in our previous investigations it was revealed that the sequence of the pK a values of the cationic acids in methanol is the same as in the water and the values are lower than those determined in acetonitrile and acetone. Also, it was found that the phenomenon of cationic homoconjugation equilibria was not present in the systems involving 4-nitropyridine N-oxide derivatives in both solvents used. Furthermore, protonation energies, ΔE prot , and Gibbs free enthalpies, ΔG prot , in vacuo have been compared with acid dissociation constants (expressed as pK a MeOH values) of the protonated N-oxides determined by potentiometric titration in methanol to establish a correlation between these magnitudes

  19. A potentiometric study of (acid+base) equilibria in substituted 4-nitropyridine N-oxide systems in methanol and dimethyl sulfoxide

    Energy Technology Data Exchange (ETDEWEB)

    Gurzynski, Lukasz [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland); Puszko, Aniela [Department of Organic Chemistry, School of Economics, Wroclaw (Poland); Makowski, Mariusz [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland); Chmurzynski, Lech [Department of General Chemistry, University of Gdansk, Sobieskiego 18, 80-952 Gdansk (Poland)]. E-mail: lech@chemik.chem.univ.gda.pl

    2007-02-15

    The acid dissociation constants for cationic acids conjugated with 4-nitropyridine N-oxides have been determined using potentiometric titration method. The measurements in the systems of thirteen 4-nitropyridine N-oxide derivatives were carried out in the polar amphiprotic methanol (MeOH) and in the aprotic protophilic dimethyl sulfoxide (DMSO). Likewise as in the polar aprotic protophobic solvents (acetonitrile, acetone) it was found that in MeOH for all N-oxides studied the pK{sub a} values were readily determinable, whereas in DMSO the pK{sub a} values were hardly determinable or indeterminable by using the potentiometric method. In addition, just like in our previous investigations it was revealed that the sequence of the pK{sub a} values of the cationic acids in methanol is the same as in the water and the values are lower than those determined in acetonitrile and acetone. Also, it was found that the phenomenon of cationic homoconjugation equilibria was not present in the systems involving 4-nitropyridine N-oxide derivatives in both solvents used. Furthermore, protonation energies, {delta}E{sub prot}, and Gibbs free enthalpies, {delta}G{sub prot}, in vacuo have been compared with acid dissociation constants (expressed as pK{sub a}{sup MeOH} values) of the protonated N-oxides determined by potentiometric titration in methanol to establish a correlation between these magnitudes.

  20. Espectrofotometria de zinco em fertilizantes em fluxo Flow injection spectrophotometry of zinc in mineral fertilizers

    Directory of Open Access Journals (Sweden)

    Arnaldo Antonio Rodella

    1999-07-01

    Full Text Available Um sistema de análise química por injeção em fluxo é proposto para a determinação espectrofotométrica de zinco em amostras de misturas de fertilizantes minerais, empregando-se zincon como reagente cromogênico. O procedimento analítico envolve redução de íons metálicos por ácido ascórbico, complexação com íon cianeto, seguindo-se a descomplexação seletiva do zinco com formaldeído, liberando-o para que reaja com o zincon formando um complexo azul. A aplicação do método proposto à extratos de mistura de fertilizantes indicou que a ação de interferentes pode ser contornada e que resultados comparáveis aos da espectrometria de absorção atômica são obtidos.A flow injection system for zinc analysis in mineral fertilizer mixtures is proposed using zincon as chromogenic reagent. The effect of interfering ions such as Cu2+, Fe3+, Mn2+ was eliminated by reduction (using ascorbic acid and complexation of these metal íons with cyanide, with zinc included. Zinc is allowed to react with zincon only after the destruction of the zinc cyano complex with formaldehyde. Flow injection analysis permitted efficient control of the reaction time so that only the zinc ion is set free to produce a blue complex with zincon. Zinc was determined in 16 fertilizer mixtures (3 replicates with precision and accuracy comparable to atomic absorption spectrometry.

  1. Selection of geohydrologic boundaries for ground-water flow models, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Downey, J.S.; Gutentag, E.D.; Kolm, K.E.

    1990-01-01

    The conceptual ground-water model of the southern Nevada/Death Valley, California region presented in this paper includes two aquifer systems: a shallow, intermontane, mostly unconfined aquifer composed of unconsolidated or poorly consolidated sediments and consolidated, layered volcanics, and a deep, regional multiple-layered, confined aquifer system composed of faulted and fractured carbonate and volcanic rocks. The potentiometric surfaces of both aquifer systems indicate that ground water leaks vertically from the deeper to the shallower geologic units, and that water in the shallower aquifer may not flow beyond the intermontane subbasin, whereas water in the deeper aquifer may indicate transbasinal flow to the playas in Death Valley. Most of the hydrologic boundaries of the regional aquifer systems in the Yucca Mountain region are geologically complex. Most of the existing numerical models simulating the ground-water flow system in the Yucca Mountain region are based on limited potentiometric-head data elevation and precipitation estimates, and simplified geology. These models are two-dimensional, and are not adequate. The alternative approach to estimating unknown boundary conditions for the regional ground-water flow system involves the following steps: (1) Incorporate known boundary-conditions data from the playas in Death Valley and the Ash Meadows spring line; (2) use estimated boundary data based on geological, pedological, geomorphological, botanical, and hydrological observations; (3) test these initial boundary conditions with three-dimensional models, both steady-state and transient; (4) back-calculate the boundary conditions for the northern, northwestern, northeastern and eastern flux boundaries; (5) compare these calculated values with known data during model calibration steps; and (6) adjust the model. 9 refs., 6 figs

  2. Analysis of mathematical modelling on potentiometric biosensors.

    Science.gov (United States)

    Mehala, N; Rajendran, L

    2014-01-01

    A mathematical model of potentiometric enzyme electrodes for a nonsteady condition has been developed. The model is based on the system of two coupled nonlinear time-dependent reaction diffusion equations for Michaelis-Menten formalism that describes the concentrations of substrate and product within the enzymatic layer. Analytical expressions for the concentration of substrate and product and the corresponding flux response have been derived for all values of parameters using the new homotopy perturbation method. Furthermore, the complex inversion formula is employed in this work to solve the boundary value problem. The analytical solutions obtained allow a full description of the response curves for only two kinetic parameters (unsaturation/saturation parameter and reaction/diffusion parameter). Theoretical descriptions are given for the two limiting cases (zero and first order kinetics) and relatively simple approaches for general cases are presented. All the analytical results are compared with simulation results using Scilab/Matlab program. The numerical results agree with the appropriate theories.

  3. The uncertainty evaluation of measurement for uranium in UF_6 hydrolysate by potentiometric titration

    International Nuclear Information System (INIS)

    Jiang Haiying; Cheng Ruoyu; Meng Xiujun

    2014-01-01

    Based on the building of mathematical model, this paper analyzed the origin of component of indeterminacy of which the measurement result for uranium in uranium hexafluoride hydrolysate by potentiometric titration, also each uncertainty was calculated and the expanded uncertainty was given. By evaluation the result of the uranium concentration is that: (158.88 + 1.22) mgU/mL, K = 2, P = 95%. (authors)

  4. Insights into the potentiometric response behaviour vs. Li+ of LiFePO4 thin films in aqueous medium

    International Nuclear Information System (INIS)

    Sauvage, F.; Tarascon, J.-M.; Baudrin, E.

    2008-01-01

    The potentiometric response of PLD-made LiFePO 4 thin films versus Li + ions in aqueous solutions has been investigated, and a sensitivity of 54 mV dec -1 has been observed in a Li + concentration range of 1-10 -4 M. Physical and electrochemical measurements of electrodes aged in aqueous medium show a slight surface oxidation with formation of heterosite-FePO 4 that we show to be responsible for the stable potential response measured. Cyclic voltamperometry measurements operated in different Li + concentration clearly highlight the key relation between the material lithium ion insertion/de-insertion capability and its potentiometric sensing response implying a faradaic-governed sensing mechanism. Based on such a finding, selection criteria (enlisting among others the potential of the redox couple, the nature of the insertion process) are herein underlined in the search for new sensitive materials

  5. Flow injection chemiluminescence determination of lercanidipine based on N-chlorosuccinimide-eosin Y post-chemiluminescence reaction.

    Science.gov (United States)

    Wang, Guowei; Zhao, Fang; Gao, Ying

    2014-12-01

    A novel post-chemiluminescence (PCL) reaction was discovered when lercanidipine was injected into the CL reaction mixture of N-chlorosuccinimide with alkaline eosin Y in the presence of cetyltrimethylammonium bromide (CTAB), where eosin Y was used as the CL reagent and CTAB as the surfactant. Based on this observation, a simple and highly sensitive PCL method combined with a flow injection (FI) technique was developed for the assay of lercanidipine. Under optimum conditions, the CL signal was linearly related to the concentration of lercanidipine in the range 7.0 × 10(-10) to 3.0 × 10(-6)  g/mL with a detection limit of 2.3 × 10(-10) g/mL (3σ). The relative standard deviation (RSD) was 2.1% for 1.0 × 10(-8) g/mL lercanidipine (n = 13). The proposed method had been applied to the estimation of lercanidipine in tablets and human serum samples with satisfactory results. The possible CL mechanism is also discussed briefly. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Simulation of Spray Injection in the Pressurizer Using RELAP5

    Directory of Open Access Journals (Sweden)

    S. Dibyo

    2017-08-01

    Full Text Available A modeling research using Relap5 to assess the pressurizer of a pressurized water reactor(PWR power plant has been performed. The heater and water injection systems in the pressurizer system of the PWRare of greatimportance for system pressure control.The heater is designed to increase the pressure while the water sprayer injection is to perform depressurization. Most of studies conducted in the past mainly focused on determining the effects of nozzle spray design and droplet size using testing loops. The purpose of this simulation is to analyze the spray injection flow rate against the pressure characteristics of the pressurizer using RELAP5. Through this approach, the optimum injection flow rate of full scale plant pressurizer can be analyzed. The parameters investigated are pressure and temperature.In RELAP5, the pressurizer tank wasmodeled with six volume nodes and the heater was modeled by using heat structure. In the model, the sprayer takes water from the cold leg to inject it into the top of tank region.The resultsshowedthat the mass flow of about 4 kg/s is the mosteffectivevalueto limit pressure in the pressurizer to below 15.7 MPa. However, the flow rates of 8 kg/s and more cause overpressure. This simulation is usefulto complement the data related to the water flow rate injection systems of the pressurizer. Normal 0 false false false EN-US X-NONE X-NONE Viscous hydrophilic injection matrices for serial crystallography

    Directory of Open Access Journals (Sweden)

    Gabriela Kovácsová

    2017-07-01

    Full Text Available Serial (femtosecond crystallography at synchrotron and X-ray free-electron laser (XFEL sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X-ray exposure, which can be achieved using a variety of methods, including various injection techniques. The latter vary significantly in their flow rates – gas dynamic virtual nozzle based injectors provide very thin fast-flowing jets, whereas high-viscosity extrusion injectors produce much thicker streams with flow rates two to three orders of magnitude lower. High-viscosity extrusion results in much lower sample consumption, as its sample delivery speed is commensurate both with typical XFEL repetition rates and with data acquisition rates at synchrotron sources. An obvious viscous injection medium is lipidic cubic phase (LCP as it is used for in meso membrane protein crystallization. However, LCP has limited compatibility with many crystallization conditions. While a few other viscous media have been described in the literature, there is an ongoing need to identify additional injection media for crystal embedding. Critical attributes are reliable injection properties and a broad chemical compatibility to accommodate samples as heterogeneous and sensitive as protein crystals. Here, the use of two novel hydrogels as viscous injection matrices is described, namely sodium carboxymethyl cellulose and the thermo-reversible block polymer Pluronic F-127. Both are compatible with various crystallization conditions and yield acceptable X-ray background. The stability and velocity of the extruded stream were also analysed and the dependence of the stream velocity on the flow rate was measured. In contrast with previously characterized injection media, both new

  7. Potentiometric and amperometric titration of ferrocene by cerium(4)

    International Nuclear Information System (INIS)

    Solomatin, V.T.

    1985-01-01

    Redox-potentials (E) of ferrocene (ferricenium-cation), Ce(4)/Ce(3) pairs are investigated and a possibility of regulating E value of these systems depending on the composition of water-organic media is shown. E value of Ce(4)/Ce(3) system decreases as increasing H 2 SO 4 concentration and CH 3 COOH mol share in the water-organic phase. Kinetic investigations of Ce(4)-ferrocene reactions shown that E constant value is achieved in 12-16 s depending on donor-acceptor properties of the solvent. Optimum conditions are chosen for potentiometric and amperometric titration of ferrocene by ceruium (4) in technological products. The method is versatile and permits to determine from tenths to dozens per cent of ferrocene

  8. Flow injection on-line spectrophotometric determination of thorium(IV) after preconcentration on XAD-4 resin impregnated with oxytetracycline

    Energy Technology Data Exchange (ETDEWEB)

    Shahida, Shabnam; Khan, Muhammad Haleem [Univ. of Azad Jammu and Kashmir, Muzaffarabad (Pakistan). Dept. of Chemistry; Ali, Akbar [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.

    2014-02-15

    A very sensitive, selective and simple flow injection time-based method was developed for on-line preconcentration and determination of thorium(IV) at micro g L{sup -1} levels in environmental samples. The system operation was based on thorium(IV) ion retention at pH 4.0 in the minicolumn at a flow rate of 15.2 mL min{sup -1}. The trapped complex was then eluted with 3.6 mol L{sup -1} HCl at a flow rate of 4.9 mL min{sup -1}. The amount of thorium(IV) in the eluate was measured spectrophotometrically at 651 nm using arsenazo-III solution (0.05 % in 3.6 mol L{sup -1} HCl stabilized with 1 % triton X-100, 4.9 mL min{sup -1}) as colorimetric reagent. All chemical, and flow injection variables were optimized for the quantitative preconcentration of metal and a study of interference level of various ions was also carried out. The system offered low backpressure and improved sensitivity and selectivity. At a preconcentration time of 60 s and a sample frequency of 40 h{sup -1}, the enhancement factor was 97, the detection limit was 0.25 μg L{sup -1}, and the precision expressed as relative standard deviation was 1.08 % (at 50 μg L{sup -1}), whereas for 300 s of the preconcentration time and a sample frequency of 10 h{sup -1}, the enhancement factor of 357, the detection limit (3s) of 0.069 μg L{sup -1} and the precision of 1.32 % (at 10 μg L{sup -1}) was reported. The accuracy of the developed method was sufficient and evaluated by the analysis of certified reference material IAEA-SL-1 (Lake Sediment) and spiked water samples.

  9. Flow injection on-line spectrophotometric determination of thorium(IV) after preconcentration on XAD-4 resin impregnated with oxytetracycline

    International Nuclear Information System (INIS)

    Shahida, Shabnam; Khan, Muhammad Haleem; Ali, Akbar

    2014-01-01

    A very sensitive, selective and simple flow injection time-based method was developed for on-line preconcentration and determination of thorium(IV) at micro g L"-"1 levels in environmental samples. The system operation was based on thorium(IV) ion retention at pH 4.0 in the minicolumn at a flow rate of 15.2 mL min"-"1. The trapped complex was then eluted with 3.6 mol L"-"1 HCl at a flow rate of 4.9 mL min"-"1. The amount of thorium(IV) in the eluate was measured spectrophotometrically at 651 nm using arsenazo-III solution (0.05 % in 3.6 mol L"-"1 HCl stabilized with 1 % triton X-100, 4.9 mL min"-"1) as colorimetric reagent. All chemical, and flow injection variables were optimized for the quantitative preconcentration of metal and a study of interference level of various ions was also carried out. The system offered low backpressure and improved sensitivity and selectivity. At a preconcentration time of 60 s and a sample frequency of 40 h"-"1, the enhancement factor was 97, the detection limit was 0.25 μg L"-"1, and the precision expressed as relative standard deviation was 1.08 % (at 50 μg L"-"1), whereas for 300 s of the preconcentration time and a sample frequency of 10 h"-"1, the enhancement factor of 357, the detection limit (3s) of 0.069 μg L"-"1 and the precision of 1.32 % (at 10 μg L"-"1) was reported. The accuracy of the developed method was sufficient and evaluated by the analysis of certified reference material IAEA-SL-1 (Lake Sediment) and spiked water samples.

  10. Numerical simulation in steam injection process by a mechanistic approach

    Energy Technology Data Exchange (ETDEWEB)

    De Souza, J.C.Jr.; Campos, W.; Lopes, D.; Moura, L.S.S. [Petrobras, Rio de Janeiro (Brazil)

    2008-10-15

    Steam injection is a common thermal recovery method used in very viscous oil reservoirs. The method involves the injection of heat to reduce viscosity and mobilize oil. A steam generation and injection system consists primarily of a steam source, distribution lines, injection wells and a discarding tank. In order to optimize injection and improve the oil recovery factor, one must determine the parameters of steam flow such as pressure, temperature and steam quality. This study focused on developing a unified mathematical model by means of a mechanistic approach for two-phase steam flow in pipelines and wells. The hydrodynamic and heat transfer mechanistic model was implemented in a computer simulator to model the parameters of steam injection while trying to avoid the use of empirical correlations. A marching algorithm was used to determine the distribution of pressure and temperature along the pipelines and wellbores. The mathematical model for steam flow in injection systems, developed by a mechanistic approach (VapMec) performed well when the simulated values of pressures and temperatures were compared with the values measured during field tests. The newly developed VapMec model was incorporated in the LinVap-3 simulator that constitutes an engineering supporting tool for steam injection wells operated by Petrobras. 23 refs., 7 tabs., 6 figs.

  11. Determination of sulfur compounds in hydrotreated transformer base oil by potentiometric titration.

    Science.gov (United States)

    Chao, Qiu; Sheng, Han; Cheng, Xingguo; Ren, Tianhui

    2005-06-01

    A method was developed to analyze the distribution of sulfur compounds in model sulfur compounds by potentiometric titration, and applied to analyze hydrotreated transformer base oil. Model thioethers were oxidized to corresponding sulfoxides by tetrabutylammonium periodate and sodium metaperiodate, respectively, and the sulfoxides were titrated by perchloric acid titrant in acetic anhydride. The contents of aliphatic thioethers and total thioethers were then determined from that of sulfoxides in solution. The method was applied to determine the organic sulfur compounds in hydrotreated transformer base oil.

  12. Recharge Area, Base-Flow and Quick-Flow Discharge Rates and Ages, and General Water Quality of Big Spring in Carter County, Missouri, 2000-04

    Science.gov (United States)

    Imes, Jeffrey L.; Plummer, Niel; Kleeschulte, Michael J.; Schumacher, John G.

    2007-01-01

    Exploration for lead deposits has occurred in a mature karst area of southeast Missouri that is highly valued for its scenic beauty and recreational opportunities. The area contains the two largest springs in Missouri (Big Spring and Greer Spring), both of which flow into federally designated scenic rivers. Concerns about potential mining effects on the area ground water and aquatic biota prompted an investigation of Big Spring. Water-level measurements made during 2000 helped define the recharge area of Big Spring, Greer Spring, Mammoth Spring, and Boze Mill Spring. The data infer two distinct potentiometric surfaces. The shallow potentiometric surface, where the depth-to-water is less than about 250 feet, tends to mimic topographic features and is strongly controlled by streams. The deep potentiometric surface, where the depth-to-water is greater than about 250 feet represents ground-water hydraulic heads within the more mature karst areas. A highly permeable zone extends about 20 mile west of Big Spring toward the upper Hurricane Creek Basin. Deeper flowing water in the Big Spring recharge area is directed toward this permeable zone. The estimated sizes of the spring recharge areas are 426 square miles for Big Spring, 352 square miles for Greer Spring, 290 square miles for Mammoth Spring, and 54 square miles for Boze Mill Spring. A discharge accumulation curve using Big Spring daily mean discharge data shows no substantial change in the discharge pattern of Big Spring during the period of record (water years 1922 through 2004). The extended periods when the spring flow deviated from the trend line can be attributed to prolonged departures from normal precipitation. The maximum possible instantaneous flow from Big Spring has not been adequately defined because of backwater effects from the Current River during high-flow conditions. Physical constraints within the spring conduit system may restrict its maximum flow. The largest discharge measured at Big Spring

  13. Validation of analytical procedure of quantitative determination of 5,7-bis(meta-nitrophenylamino-4,6-dinitrobenzofuroxan by potentiometric titration

    Directory of Open Access Journals (Sweden)

    R. Sh. Markhabullina

    2014-01-01

    Full Text Available A new method of quantitative determination of the substance of 5,7-bis(meta-nitrophenylamino-4,6-dinitrobenzofuroxan using potentiometric titration method is developed. The method has high precision, reliability and sensitivity.

  14. Influence of morphology and topography on potentiometric response of magnesium and calcium sensitive PEDOT films doped with adenosine triphosphate (ATP)

    International Nuclear Information System (INIS)

    Paczosa-Bator, B.; Peltonen, J.; Bobacka, J.; Lewenstam, A.

    2006-01-01

    Poly(3,4-ethylenedioxythiophene) (PEDOT) films doped with adenosine triphosphate (ATP) are used to study the biologically relevant competitive magnesium and calcium ion-exchange at ATP membrane sites. It is shown, by atomic force microscopy (AFM) and scanning electron microscopy (SEM), that the surface topography and morphology of the PEDOT-ATP films determines the quality of their potentiometric response. More smooth and less rough films result in better potentiometric characteristics, particularly in a faster response. The topography/morphology of the PEDOT-ATP films is influenced by conditions during electrodeposition (electrochemical method of deposition, pH, concentration of electrolytes) and post-deposition soaking (including net-time of soaking), as evidenced by X-ray photoelectron spectroscopy (XPS) and energy dispersive analysis of X-rays (EDAX)

  15. Porous media heat transfer for injection molding

    Science.gov (United States)

    Beer, Neil Reginald

    2016-05-31

    The cooling of injection molded plastic is targeted. Coolant flows into a porous medium disposed within an injection molding component via a porous medium inlet. The porous medium is thermally coupled to a mold cavity configured to receive injected liquid plastic. The porous medium beneficially allows for an increased rate of heat transfer from the injected liquid plastic to the coolant and provides additional structural support over a hollow cooling well. When the temperature of the injected liquid plastic falls below a solidifying temperature threshold, the molded component is ejected and collected.

  16. Label-free potentiometric biosensor based on solid-contact for determination of total phenols in honey and propolis.

    Science.gov (United States)

    Draghi, Patrícia Ferrante; Fernandes, Julio Cesar Bastos

    2017-03-01

    We developed a label-free potentiometric biosensor using tyrosinase extracted from Musa acuminata and immobilized by covalent bond on a surface of a solid-contact transducer. The transducer was manufactured containing two layers. The first layer contained a blend of poly(vinyl) chloride carboxylated (PVC-COOH), graphite and potassium permanganate. On this layer, we deposited a second layer containing just a mixture of poly(vinyl chloride) carboxylated and graphite. On the last layer of the transducer, we immobilized the tyrosinase enzyme by reaction with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride. The solid-contact potentiometric biosensor presented at low detection limit of 7.3×10 -7 M and a linear range to catechol concentration between 9.3×10 -7 M and 8.3×10 -2 M. This biosensor was applied to determine the amount of total phenols in different samples of honey and propolis. The results agreed with the Folin-Ciocalteu method. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Analysis of Lead and Zinc by Mercury-Free Potentiometric Stripping Analysis

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    A method is presented for trace-element analysis of lead and zinc by potentiometric stripping analysis (PSA) where both the glassy-carbon working electrode and the electrolyte are free of mercury. Analysis of zinc requires an activation procedure of the glassy-carbon electrode. The activation...... is performed by pre-concentrating zinc on glassy carbon at -1400 mV(SCE) in a mercury-free electrolyte containing 0.1 M HCl and 2 ppm Zn2+, followed by stripping at approx. -1050 mV. A linear relationship between stripping peak areas, recorded in the derivative mode, and concentration was found...

  18. Characterization of solid-solution interface by potentiometric titration and electrophoretic mobility

    International Nuclear Information System (INIS)

    Lindecker, C.; Drot, R.; Fourest, B.; Simoni, E.

    1999-01-01

    The study of nuclear waste storage in deep geological sites involves the understanding of processes which could produce a possible dispersion or retention of radioelements. The dispersion of solid particles in aqueous solution is consequently important to be characterized. In this bi-phased system it is necessary to determine the characteristics of the solid-solution interface. The method used of this study is the techniques of potentiometric titration applied to heterogeneous systems. The material studied were phosphate matrices which were synthesized in the laboratory. The dependence of their surface change upon the nature of the electrolytes was investigated

  19. Potentiometric pKa Determination of Piroxicam and Tenoxicam in Acetonitrile-Water Binary Mixtures

    OpenAIRE

    Çubuk Demiralay, Ebru; Yılmaz, Hülya

    2012-01-01

    Abstract: Ionization constant (pKa) is one among the parameter to be estimated with accuracy, irrespective of solubility constraints. In the present study, acid-base behaviour of the piroxicam and tenoxicam was studied. By using the potentiometric method, pKa values of piroxicam and tenoxicam have been determined in different percentage of acetonitrile-water binary mixtures (acetonitrile content between 30 and 45% in volume). Aqueous pKa values of these compounds were calculated by mole fract...

  1. Further investigation on the degree of deacetylation of chitosan determined by potentiometric titration

    OpenAIRE

    Kamal Sweidan; Abdel-Motalleb Jaber; Nawzat Al-jbour; Rana Obaidat; Mayyas Al- Remawi; Adnan Badwan

    2011-01-01

    The degree of deacetylation (DDA) of various low molecular weight chitosan (LMWC) species as the hydrochloride and free base (amine form) was determined by direct and back potentiometric titration, respectively. The DDA values obtained for the chitosan hydrochloride by direct titration were greater than 93% for all oligomers tested (Molecular weight (Mwt) between about 1.3 to 30.0 kDa). However, the DDA values obtained for chitosan amine oligomers using back titration were significantly lower...

  2. Potentiometric determination of the tungsten content of tantalum-tungsten alloys with chromium II

    International Nuclear Information System (INIS)

    Gavra, Z.; Ronen, S.; Levin, R.

    1977-05-01

    A method was developed for the potentiometric determination of the tungsten content of tantalum-tungsten alloys of different compositions. These were dissolved under conditions that enabled the tungsten content to be determined with chromium (II). Phosphoric acid was selected as a suitable complexing agent for the prevention of the precipitation of tungsten and tantalum compounds. The use of chromium (II) required an oxygen-tight system and therefore the work was carried out in suitable vessels for storage and tritation

  3. A Simple and Rapid Flow-Injection Chemiluminescence Method for the Determination of Noscapine with Ru(phen)32+-Ce(4) System

    International Nuclear Information System (INIS)

    Rezaei, B.; Mokhtari, A.; Khayamian, T.

    2007-01-01

    A new flow injection chemiluminescence (CL) system was used for the determination of noscapine. This technique is based on the reduction effect of noscapine on the Ru(phen) 3 3+ , which is produced by reaction between Ru(phen) 3 2+ and acidic Ce(4) solutions, and this rapid reduction produces strong CL. Calibration plots were linear over the range of 3.0x10 -7 -2.0x10 -6 mol L -1 and 2.0x10 -6 -2.0x10 -4 mol L -1 . The CL intensity was so high, that it is able to produce a detection limit of 6.6x10 -8 M noscapine (3σ). The relative standard deviation of 2.0x10 -6 M noscapine was 1.0% (n=10). The proposed method was successfully applied for the flow injection determination of noscapine in cough and Tonin syrup samples. The results of real sample analyses show good recovery percentages (97.3-102.4%). The minimum sampling rate was 100 samples per hour

  4. Scanning electrochemical microscopy determination of hydrogen flux at liquid|liquid interface with potentiometric probe

    OpenAIRE

    Jedraszko, Justyna; Nogala, Wojciech; Adamiak, Wojciech; Girault, Hubert H.; Opallo, Marcin

    2014-01-01

    Scanning electrochemical microscopy potentiometric determination of local hydrogen concentration and its flux next to the liquid|liquid interface was demonstrated. This method is based on the shift of open circuit potential of Pt-based reversible hydrogen electrode. The detection system was verified with a system generating hydrogen under galvanostatic conditions. Then, it was applied to aqueous|1,2-dichloroethane interface where hydrogen is produced with decamethylferrocene as electron donor.

  5. Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system.

    Science.gov (United States)

    Jakmunee, Jaroon; Junsomboon, Jaroon

    2009-09-15

    A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extracting solution (0.05 M HCl+0.0125 M H(2)SO(4)) was used to extract the sample under gravity flow and the eluate was collected in a polyethylene bottle. The extract was then analyzed for phosphorus contents by a simple flow injection amperometric system, employing a set of three-way solenoid valves as an injection valve. The method is based on the electrochemical reduction of 12-molybdophosphate which is produced on-line by the reaction of orthophosphate with acidic molybdate and the electrical current produced was directly proportional to the concentration of phosphate in range of 0.1-10.0 mg L(-1) PO(4)-P, with a detection limit of 0.02 mg L(-1). Relative standard for 11 replicate injections of 5 mg L(-1) PO(4)-P was 0.5%. A sample through put of 35 h(-1) was achieved, with consumption of 14 mg KCl, 10mg ammonium molybdate and 0.05 mL H(2)SO(4) per analysis. The detection system does not suffer from the interferences that are encountered in the photometric method such as colored substances, colloids, metal ions, silicate and refractive index effect (Schlieren effect). The results obtained by the column extraction procedure were well correlated with those obtained by the steady-state extraction procedure, but showed slightly higher extraction efficiency.

  6. Injection of nano-particles in mitigating flow accelerated corrosion (FAC) damage in the secondary system of nuclear power plants (NPPs)

    International Nuclear Information System (INIS)

    Lim, Dong Seok; Ku, Hee Kwon; Cho, Jae Seon

    2015-01-01

    NPPs produces electric energy through phase transition of water. According to this, a piping, which is flow path, integrity is essential for safety functions. Erosion, FAC and fittings are corrosion failure mechanism by increasing service life. Especially, there are 10-kilometers of piping in secondary systems. It needs to estimate FAC and apply periodic management. Iron oxides produced by FAC cause power reduction and Loss Of Coolant Accident (LOCA) will be occurred through the continued piping wall thinning. In this study, corrosion rate of pipe materials with carbon steel(SA106.Gr.B) and low-alloy steel (SA335.P22) was evaluated for pipe configuration and dissolved oxygen concentration on 150 °C, pH 9.5∼10.0 and flow velocity of 5m/s. Temperature of 150°C is well known that causes high FAC rate and pH consider a NPPs in-service condition. Further corrosion rate test was performed to develop FAC reduction technology through Pt-nanoparticle injection. In this study, corrosion rate is evaluated by weight depletion method. The results of material impact assessment show that corrosion rate of carbon steel is more higher than that of low-alloy steel because of Cr content. And also, the results of pipe configuration test show that case with 90° elbow had maximum wall thinning than with 180° horizontal pipe. The dissolved oxygen concentration test shows that low oxygen condition, ≤5 ppb, had high corrosion rate compared to normal condition and the corrosion rate decreased 50% at Pt-nanoparticle injection test on maximum corrosion rate condition compared to maximum wall thinning condition without Pt-nanoparticle injection. In this study, samples provided by each test case had analyzed through SEM-EDX (Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy). Behavior evaluation for oxide film was performed and Electrochemical corrosion potential (ECP) was measured for electrochemistry evaluation. To apply Pt-nanoparticle injection technology on nuclear

  7. Sibutramine selective electrodes for batch and flow injection determinations in pharmaceutical preparations.

    Science.gov (United States)

    Zayed, S I M; Issa, Y M

    2010-01-01

    The construction and electrochemical response characteristics of two new polyvinyl chloride (PVC) membrane sensors for the determination of sibutramine hydrochloride were described. The sensors are based on the ion association complexes of sibutramine with sodium tetraphenylborate (NaTPB) or phosphotungstic acid (PTA) using dibutyl phthalate as plasticizing solvent. The sensors display a fast, stable response over the concentration range 3.84 x 10(-5)-1.00 x 10(-2) M sibutramine hydrochloride monohydrate (SibuCl), with cationic slopes of 57.7 +/- 0.57 and 59.7 +/- 1.79 mV concentration decade(-1) and detection limits of 8.91 x 10(-6) and 1.47 x 10(-5) M in case of sibutramine-tetraphenylborate (Sibu-TPB) and sibutramine-phosphotungstate ((Sibu)(3)-PT), respectively. The proposed sensors have been successfully applied for the determination of sibutramine hydrochloride in Regitrim capsules in batch and flow injection (FI) conditions.

  8. A similar solution for an unsteady free convection flow past an impulsively started vertical plate with mass transfer and suction or injection

    International Nuclear Information System (INIS)

    Sattar, M.A.

    1990-12-01

    A similar solution for the flow past a vertical plate started impulsively in its own plane in a viscous incompressible fluid is presented on taking into account the effects of variable suction and/or injection and mass transfer. To solve the momentum, energy and concentration equations, a time dependent length scale is introduced, which leads to the driving parameters γ(=G r /R σ 2 ) and γ*(=G r */R σ 2 ), where G r and G r * are respectively the Grashof and modified Grashof numbers while R σ is the Reynolds number. The resulting locally similar momentum equation is then solved by the method of superposition. The effects of the parameters and that of suction/injection on the flow and on the wall shear-stress of the plate are shown graphically for different values of Schmidt number and transpiration parameter. (author). 24 refs, 11 figs

  9. Flow velocity effect on the corrosion/erosion in water injection systems; Efecto de la velocidad de flujo en la corrosion/erosion en sistemas de inyeccion de agua

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, C.; Mendez, J. [PDVSA Exploracion y reduccion, Departamento de Ingenieria de Instalaciones, Torres Petroleras EX-MRV, Torre Lama, Piso No. 6, Zulia, Apartado 4013, Venezuela (Venezuela)

    1998-12-31

    The main causes of fails at water injection lines on the secondary petroleum recovery systems are related with corrosion/erosion problems which are influenced by the flow velocity, the presence of dissolved oxygen, solids in the medium and the microorganisms proliferation. So too, this corrosion process promotes the suspended solids generation which affects the water quality injected, causing wells tamponage and loss of injectivity, with the consequent decrease in the crude production. This situation has been impacted in meaning order at the production processes of an exploration enterprise which utilizes the Maracaibo lake as water resource for their injection by pattern projects. Stating that, it was developed a study for determining in experimental order the effect of flow velocity on the corrosion/erosion process joined to the presence of dissolved oxygen which allows to determine the optimum range of the said working velocity for the water injection systems. This range is defined by critical velocities of bio layers deposition and erosion. They were realized simulation pilot tests of the corrosion standard variables, concentration of dissolved oxygen and fluid velocity in the injection systems with filtered and non filtered water. For the development of these tests it was constructed a device which allows to install and expose cylindrical manometers of carbon steel according to predetermined conditions which was obtained the necessary information to make correlations the results of these variables. Additionally, they were determined the mathematical models that adjusts to dynamical behavior of the corrosion/erosion process, finding the optimum range of the flow velocity for the control of this process, being necessary to utilize the following techniques: Scanning Electron Microscopy (SEM), X-ray dispersion analysis (EDX) for encourage the surface studies. They were effected morphological analysis of the surfaces studies and the values were determined of

  10. Flow injection analysis-flame atomic absorption spectrometry system for indirect determination of sulfite after on-line reduction of solid-phase manganese (IV) dioxide reactor.

    Science.gov (United States)

    Zare-Dorabei, Rouholah; Boroun, Shokoufeh; Noroozifar, Meissam

    2018-02-01

    A new and simple flow injection method followed by atomic absorption spectrometry was developed for indirect determination of sulfite. The proposed method is based on the oxidation of sulfite to sulphate ion using solid-phase manganese dioxide (30% W/W suspended on silica gel beads) reactor. MnO 2 will be reduced to Mn(II) by sample injection in to the column under acidic carrier stream of HNO 3 (pH 2) with flow rate of 3.5mLmin -1 at room temperature. Absorption measurement of Mn(II) which is proportional to the concentration of sulfite in the sample was carried out by atomic absorption spectrometry. The calibration curve was linear up to 25mgL -1 with a detection limit (DL) of 0.08mgL -1 for 400µL injection sample volume. The presented method is efficient toward sulfite determination in sugar and water samples with a relative standard deviation (RSD) less than 1.2% and a sampling rate of about 60h -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A nanoporous ruthenium oxide framework for amperometric sensing of glucose and potentiometric sensing of pH

    International Nuclear Information System (INIS)

    Shim, J.H.; Kang, M.; Lee, Y.; Lee, C.

    2012-01-01

    Nanoporous ruthenium oxide frameworks (L 2 -eRuO) were electrodeposited on gold substrates by repetitive potential cycling in solutions of ruthenium(III) ions in the presence of reverse neutral micelles. The L 2 -eRuO was characterized in terms of direct oxidation of glucose and potentiometric response to pH values. The surface structures and morphologies of the L 2 -eRuO were characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, Raman spectroscopy, and high-resolution transmission electron microscopy. Their surface area was estimated via underpotential deposition of copper. L 2-eRuO-modified electrodes showed a 17-fold higher sensitivity (40 μA mM -1 cm -2 towards glucose in 0-4 mM concentration in solution of pH 7.4) than a RuO electrode prepared in the absence of reverse micelles. Potential interferents such as ascorbic acid, 4-acetamidophenol, uric acid and dopamine displayed no effect. The new electrode also revealed improved potentiometric response to pH changes compared to a platinum electrode of the same type. (author)

  12. Potentiometric Membrane Sensors for Levamisole Determination

    Directory of Open Access Journals (Sweden)

    Natalia Zubenya

    2016-11-01

    Full Text Available The ion pair (IP of levamisole with BiI4-(SbI4- for the levamisole-selective sensor with a PVC membrane containing - ions were developed. Thermal behavior of obtained IP was investigated by differential thermal analysis that would show the thermal stability and the character of the decomposition of the complex. The thermolysis of Lev+BiI4- IP undergoes three stages that fit a theoretical interpretation. the linearity ranges of levamisole sensors function are 7.9 ×10-6 – 1×10-1 (7.9 ×10-5 – 1×10-1 M. The Nernstian slope of                   50.6 – 53.4 mV pC−1 and detection limit of 5.0 × 10−5 – 1.5 × 10−4 M. The working range of pH is 2.8 – 6.0.     The efficiency of the use of electrodes for levamisole content control in pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.

  13. Analysis of large break loss of coolant accident with simultaneous injection into cold leg and hot leg

    International Nuclear Information System (INIS)

    Luo Bangqi

    1997-01-01

    When a large break loss of coolant accident occurs, the most part of the safety injection water injected into the cold leg by the safety injection system will flow through the channel between the pressure vessel and the barrel out of the break into the containment, only a little part of the safety injection water can flow into the reactor core. If the safety injection can inject into both the cold leg and the hot leg simultaneously, the safety injection water injected from the cold leg will flow into the core more easily, because the safety injection water injected from the hot leg will carry out more heat from the upper plenum and the core, so the upper plenum and the core is depressed. In addition, a small part of the safety injection water injected from the hot leg will flow down in the core after impinging the guide tubes in the upper plenum, so the core will get more safety injection water than only cold leg injection, and the core will be much safer

  14. Optimal Power Flow Control by Rotary Power Flow Controller

    Directory of Open Access Journals (Sweden)

    KAZEMI, A.

    2011-05-01

    Full Text Available This paper presents a new power flow model for rotary power flow controller (RPFC. RPFC injects a series voltage into the transmission line and provides series compensation and phase shifting simultaneously. Therefore, it is able to control the transmission line impedance and the active power flow through it. An RPFC is composed mainly of two rotary phase shifting transformers (RPST and two conventional (series and shunt transformers. Structurally, an RPST consists of two windings (stator and rotor windings. The rotor windings of the two RPSTs are connected in parallel and their stator windings are in series. The injected voltage is proportional to the vector sum of the stator voltages and so its amplitude and angle are affected by the rotor position of the two RPSTs. This paper, describes the steady state operation and single-phase equivalent circuit of the RPFC. Also in this paper, a new power flow model, based on power injection model of flexible ac transmission system (FACTS controllers, suitable for the power flow analysis is introduced. Proposed model is used to solve optimal power flow (OPF problem in IEEE standard test systems incorporating RPFC and the optimal settings and location of the RPFC is determined.

  15. Potentiometric chemical sensors from lignin-poly(propylene oxide) copolymers doped by carbon nanotubes.

    Science.gov (United States)

    Rudnitskaya, Alisa; Evtuguin, Dmitry V; Costa, Luis C; Graça, M Pedro F; Fernandes, António J S; Correia, M Rosario P; Gomes, M Teresa S R; Oliveira, J A B P

    2013-01-21

    Hardwood and softwood lignins obtained from industrial sulphite and kraft and laboratory oxygen-organosolv pulping processes were employed in co-polymerization with tolylene 2,4-diisocyanate terminated poly(propylene glycol). The obtained lignin-based polyurethanes were doped with 0.72 w/w% of multiwall carbon nanotubes (MWCNTs) with the aim of increasing their electrical conductivity to the levels suitable for sensor applications. Effects of the polymer doping with MWCNTs were assessed using electrical impedance (EIS) and UV-Resonance Raman (UV-RR) spectroscopy. Potentiometric sensors were prepared by drop casting of liquid polymer on the surface of carbon glass or platinum electrodes. Lignin-based sensors displayed a very low or no sensitivity to all alkali, alkali-earth and transition metal cations ions except Cr(VI) at pH 2. Response to Cr(VI) values of 39, 50 and 53 mV pX(-1) for the sensors based on kraft, organosolv and lignosulphonate lignins, respectively, were observed. Redox sensitivity values close to the theoretical values of 20 and 21 mV pX(-1) for organosolv and lignosulphonate based sensors respectively were detected in the Cr(III)/Cr(VI) solutions while a very low response was observed in the solutions containing Fe(CN)(6)(3-/4-). Conducting composite lignin-based polyurethanes doped with MWCNTs were suggested as being promising materials for Cr(VI)-sensitive potentiometric sensors.

  16. Photometric estimation of plutonium in product solutions and acid waste solutions using flow injection analysis technique

    International Nuclear Information System (INIS)

    Dhas, A.J.A.; Dharmapurikar, G.R.; Kumaraguru, K.; Vijayan, K.; Kapoor, S.C.; Ramanujam, A.

    1995-01-01

    Flow injection analysis technique is employed for the measurement of plutonium concentrations in product nitrate solutions by measuring the absorbance of Pu(III) at 565 nm and of Pu(IV) at 470 nm, using a Metrohm 662 photometer, with a pyrex glass tube of 2 nm (ID) inserted in the light path of the detector serving as a flow cell. The photometer detector never comes in contact with radioactive solution. In the case of acid waste solutions Pu is first purified by extraction chromatography with 2-ethyl hexyl hydrogen 2 ethyl hexyl phosphonate (KSM 17)- chromosorb and the Pu in the eluate in complexed with Arsenazo III followed by the measured of absorbance at 665 nm. Absorbance of reference solutions in the desired concentration ranges are measured to calibrate the system. The results obtained agree with the reference values within ±2.0%. (author). 3 refs., 1 tab

  17. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  18. Two-dimensional analysis of two-phase reacting flow in a firing direct-injection diesel engine

    Science.gov (United States)

    Nguyen, H. Lee

    1989-01-01

    The flow field, spray penetration, and combustion in two-stroke diesel engines are described. Fuel injection begins at 345 degrees after top dead center (ATDC) and n-dodecane is used as the liquid fuel. Arrhenius kinetics is used to calculate the reaction rate term in the quasi-global combustion model. When the temperature, fuel, and oxygen mass fraction are within suitable flammability limits, combustion begins spontaneously. No spark is necessary to ignite a localized high temperature region. Compression is sufficient to increase the gaseous phase temperature to a point where spontaneous chemical reactions occur. Results are described for a swirl angle of 22.5 degrees.

  19. Semi-automatic version of the potentiometric titration method for characterization of uranium compounds.

    Science.gov (United States)

    Cristiano, Bárbara F G; Delgado, José Ubiratan; da Silva, José Wanderley S; de Barros, Pedro D; de Araújo, Radier M S; Dias, Fábio C; Lopes, Ricardo T

    2012-09-01

    The potentiometric titration method was used for characterization of uranium compounds to be applied in intercomparison programs. The method is applied with traceability assured using a potassium dichromate primary standard. A semi-automatic version was developed to reduce the analysis time and the operator variation. The standard uncertainty in determining the total concentration of uranium was around 0.01%, which is suitable for uranium characterization and compatible with those obtained by manual techniques. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of {alpha}-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yafeng [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China); Zhuang Yafeng [Department of Chemistry, Changzhou Institute of Technology, Changzhou 213022 (China); Liu Songqin [Jiangsu Provincial Key Lab of Biomaterials and Biodevices, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 210096 (China)], E-mail: liusq@seu.edu.cn; He Lin [Department of Chemistry, North Carolina State University, Raleigh, NC 27695-8204 (United States)

    2008-12-23

    A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with {gamma}-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The {alpha}-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL{sup -1}. The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis.

  1. Dysprosium selective potentiometric membrane sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Faridbod, Farnoush; Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of)

    2013-03-01

    A novel Dy(III) ion-selective PVC membrane sensor was made using a new synthesized organic compound, 3,4-diamino-N Prime -((pyridin-2-yl)methylene)benzohydrazide (L) as an excellent sensing element. The electrode showed a Nernstian slope of 19.8 {+-} 0.6 mV per decade in a wide concentration range of 1.0 Multiplication-Sign 10{sup -6}-1.0 Multiplication-Sign 10{sup -2} mol L{sup -1}, a detection limit of 5.5 Multiplication-Sign 10{sup -7} mol L{sup -1}, a short conditioning time, a fast response time (< 10 s), and high selectivity towards Dy(III) ion in contrast to other cations. The proposed sensor was successfully used as an indicator electrode in the potentiometric titration of Dy(III) ions with EDTA. The membrane sensor was also applied to the F{sup -} ion indirect determination of some mouth washing solutions and to the Dy{sup 3+} determination in binary mixtures. Highlights: Black-Right-Pointing-Pointer The novelty of this work is based on the high affinity of the ionophore toward the Dy{sup 3+} ions. Black-Right-Pointing-Pointer This technique is very simple, fast and inexpensive and it is not necessary to use sophisticated equipment. Black-Right-Pointing-Pointer The newly developed sensor is superior to the formerly reported Dy{sup 3+} sensors in terms of selectivity.

  2. Application of cause-and-effect analysis to potentiometric titration.

    Science.gov (United States)

    Kufelnicki, A; Lis, S; Meinrath, G

    2005-08-01

    A first attempt has been made to interpret physicochemical data from potentiometric titration analysis in accordance with the complete measurement-uncertainty budget approach (bottom-up) of ISO and Eurachem. A cause-and-effect diagram is established and discussed. Titration data for arsenazo III are used as a basis for this discussion. The commercial software Superquad is used and applied within a computer-intensive resampling framework. The cause-and-effect diagram is applied to evaluation of seven protonation constants of arsenazo III in the pH range 2-10.7. The data interpretation is based on empirical probability distributions and their analysis by second-order correct confidence estimates. The evaluated data are applied in the calculation of a speciation diagram including uncertainty estimates using the probabilistic speciation software Ljungskile.

  3. Hydrogen/oxygen injection stopping method for nuclear power plant and emergent hydrogen/oxygen injection device

    International Nuclear Information System (INIS)

    Ishida, Ryoichi; Ota, Masamoto; Takagi, Jun-ichi; Hirose, Yuki

    1998-01-01

    The present invention provides a device for suppressing increase of electroconductivity of reactor water during operation of a BWR type reactor, upon occurrence of reactor scram of the plant or upon stopping of hydrogen/oxygen injection due to emergent stoppage of an injection device so as not to deteriorate the integrity of a gas waste processing system upon occurrence of scram. Namely, when injection of hydrogen/oxygen is stopped during plant operation, the injection amount of hydrogen is reduced gradually. Subsequently, injection of hydrogen is stopped. With such procedures, the increase of electroconductivity of reactor water can be suppressed upon stoppage of hydrogen injection. When injection of hydrogen/oxygen is stopped upon shut down of the plant, the amount of hydrogen injection is changed depending on the change of the feedwater flow rate, and then the plant is shut down while keeping hydrogen concentration of feedwater to a predetermined value. With such procedures, increase of the reactor water electroconductivity can be suppressed upon stoppage of hydrogen injection. Upon emergent stoppage of the hydrogen/oxygen injection device, an emergent hydrogen/oxygen injection device is actuated to continue the injection of hydrogen/oxygen. With such procedures, elevation of reactor water electroconductivity can be suppressed. (I.S.)

  4. Seasonal Variability in Regional Ice Flow Due to Meltwater Injection Into the Shear Margins of Jakobshavn Isbræ

    Science.gov (United States)

    Cavanagh, J. P.; Lampkin, D. J.; Moon, T.

    2017-12-01

    The impact of meltwater injection into the shear margins of Jakobshavn Isbræ via drainage from water-filled crevasses on ice flow is examined. We use Landsat-8 Operational Land Imager panchromatic, high-resolution imagery to monitor the spatiotemporal variability of seven water-filled crevasse ponds during the summers of 2013 to 2015. The timing of drainage from water-filled crevasses coincides with an increase of 2 to 20% in measured ice velocity beyond Jakobshavn Isbræ shear margins, which we define as extramarginal ice velocity. Some water-filled crevasse groups demonstrate multiple drainage events within a single melt season. Numerical simulations show that hydrologic shear weakening due to water-filled crevasse drainage can accelerate extramarginal flow by as much as 35% within 10 km of the margins and enhance mass flux through the shear margins by 12%. This work demonstrates a novel mechanism through which surface melt can influence regional ice flow.

  5. Interface of Two Immiscible Electrolytes as a Potentiometric Sensor for Flow Analysis

    Czech Academy of Sciences Publication Activity Database

    Mansfeldová, Věra; Janda, Pavel; Tarábková, Hana; Kaleta, Jiří

    2016-01-01

    Roč. 49, č. 1 (2016), s. 169-177 ISSN 0003-2719 R&D Projects: GA ČR(CZ) GAP208/12/2429 Institutional support: RVO:61388955 ; RVO:61388963 Keywords : flow analysis * phthalocyanine * potentiometry Subject RIV: CG - Electrochemistry Impact factor: 1.150, year: 2016

  6. Performance and emission studies on port injection of hydrogen with varied flow rates with Diesel as an ignition source

    International Nuclear Information System (INIS)

    Saravanan, N.; Nagarajan, G.

    2010-01-01

    Automobiles are one of the major sources of air pollution in the environment. In addition CO 2 emission, a product of complete combustion also has become a serious issue due to global warming effect. Hence the search for cleaner alternative fuels has become mandatory. Hydrogen is expected to be one of the most important fuels in the near future for solving the problems of air pollution and greenhouse gas problems (carbon dioxide), thereby protecting the environment. Hence in the present work, an experimental investigation has been carried out using hydrogen in the dual fuel mode in a Diesel engine system. In the study, a Diesel engine was converted into a dual fuel engine and hydrogen fuel was injected into the intake port while Diesel was injected directly inside the combustion chamber during the compression stroke. Diesel injected inside the combustion chamber will undergo combustion first which in-turn would ignite the hydrogen that will also assist the Diesel combustion. Using electronic control unit (ECU), the injection timings and injection durations were varied for hydrogen injection while for Diesel the injection timing was 23 o crank angle (CA) before injection top dead centre (BITDC). Based on the performance, combustion and emission characteristics, the optimized injection timing was found to be 5 o CA before gas exchange top dead centre (BGTDC) with injection duration of 30 o CA for hydrogen Diesel dual fuel operation. The optimum hydrogen flow rate was found to be 7.5 lpm. Results indicate that the brake thermal efficiency in hydrogen Diesel dual fuel operation increases by 15% compared to Diesel fuel at 75% load. The NO X emissions were higher by 1-2% in dual fuel operation at full load compared to Diesel. Smoke emissions are lower in the entire load spectra due to the absence of carbon in hydrogen fuel. The carbon monoxide (CO), carbon dioxide (CO 2 ) emissions were lesser in hydrogen Diesel dual fuel operation compared to Diesel. The use of hydrogen

  7. Performance and emission studies on port injection of hydrogen with varied flow rates with Diesel as an ignition source

    Energy Technology Data Exchange (ETDEWEB)

    Saravanan, N. [ERC Engines, Tata Motors, Pimpri, Pune (India); Nagarajan, G. [Internal Combustion Engineering Division, Department of Mechanical Engineering, College of Engineering, Guindy, Anna University, Chennai (India)

    2010-07-15

    Automobiles are one of the major sources of air pollution in the environment. In addition CO{sub 2} emission, a product of complete combustion also has become a serious issue due to global warming effect. Hence the search for cleaner alternative fuels has become mandatory. Hydrogen is expected to be one of the most important fuels in the near future for solving the problems of air pollution and greenhouse gas problems (carbon dioxide), thereby protecting the environment. Hence in the present work, an experimental investigation has been carried out using hydrogen in the dual fuel mode in a Diesel engine system. In the study, a Diesel engine was converted into a dual fuel engine and hydrogen fuel was injected into the intake port while Diesel was injected directly inside the combustion chamber during the compression stroke. Diesel injected inside the combustion chamber will undergo combustion first which in-turn would ignite the hydrogen that will also assist the Diesel combustion. Using electronic control unit (ECU), the injection timings and injection durations were varied for hydrogen injection while for Diesel the injection timing was 23 crank angle (CA) before injection top dead centre (BITDC). Based on the performance, combustion and emission characteristics, the optimized injection timing was found to be 5 CA before gas exchange top dead centre (BGTDC) with injection duration of 30 CA for hydrogen Diesel dual fuel operation. The optimum hydrogen flow rate was found to be 7.5 lpm. Results indicate that the brake thermal efficiency in hydrogen Diesel dual fuel operation increases by 15% compared to Diesel fuel at 75% load. The NO{sub X} emissions were higher by 1-2% in dual fuel operation at full load compared to Diesel. Smoke emissions are lower in the entire load spectra due to the absence of carbon in hydrogen fuel. The carbon monoxide (CO), carbon dioxide (CO{sub 2}) emissions were lesser in hydrogen Diesel dual fuel operation compared to Diesel. The use of

  8. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    Directory of Open Access Journals (Sweden)

    Gervasio Ana P. G.

    2001-01-01

    Full Text Available A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major constituents such as Fe(III and Cr(III, a mini-column packed with AG50W-X8 resin was coupled to the manifold. A sample throughput of 40 determinations per hour, a dynamical range from P 0.25 to 6.00 mg L-1, a reagent consumption of 25 mg ammonium molybdate and 2 mg stannous chloride per determination, and a relative standard deviation < 1% (n = 10 for a typical sample with 2.20 mg L-1 P were achieved. Three different types of samples were used to evaluate system performance. Accuracy was assessed by comparing the results with certified values and no significant difference at 95 % confidence level was observed.

  9. Fast-responsive hydrogel as an injectable pump for rapid on-demand fluidic flow control.

    Science.gov (United States)

    Luo, Rongcong; Dinh, Ngoc-Duy; Chen, Chia-Hung

    2017-05-01

    Chemically synthesized functional hydrogels have been recognized as optimized soft pumps for on-demand fluidic regulation in micro-systems. However, the challenges regarding the slow responses of hydrogels have very much limited their application in effective fluidic flow control. In this study, a heterobifunctional crosslinker (4-hydroxybutyl acrylate)-enabled two-step hydrothermal phase separation process for preparing a highly porous hydrogel with fast response dynamics was investigated for the fabrication of novel microfluidic functional units, such as injectable valves and pumps. The cylinder-shaped hydrogel, with a diameter of 9 cm and a height of 2.5 cm at 25 °C, achieved a size reduction of approximately 70% in less than 30 s after the hydrogels were heated at 40 °C. By incorporating polypyrrole nanoparticles as photothermal transducers, a photo-responsive composite hydrogel was approached and exhibited a remotely triggerable fluidic regulation and pumping ability to generate significant flows, showing on-demand water-in-oil droplet generation by laser switching, whereby the droplet size could be tuned by adjusting the laser intensity and irradiation period with programmable manipulation.

  10. [Research on optimization of mathematical model of flow injection-hydride generation-atomic fluorescence spectrometry].

    Science.gov (United States)

    Cui, Jian; Zhao, Xue-Hong; Wang, Yan; Xiao, Ya-Bing; Jiang, Xue-Hui; Dai, Li

    2014-01-01

    Flow injection-hydride generation-atomic fluorescence spectrometry was a widely used method in the industries of health, environmental, geological and metallurgical fields for the merit of high sensitivity, wide measurement range and fast analytical speed. However, optimization of this method was too difficult as there exist so many parameters affecting the sensitivity and broadening. Generally, the optimal conditions were sought through several experiments. The present paper proposed a mathematical model between the parameters and sensitivity/broadening coefficients using the law of conservation of mass according to the characteristics of hydride chemical reaction and the composition of the system, which was proved to be accurate as comparing the theoretical simulation and experimental results through the test of arsanilic acid standard solution. Finally, this paper has put a relation map between the parameters and sensitivity/broadening coefficients, and summarized that GLS volume, carrier solution flow rate and sample loop volume were the most factors affecting sensitivity and broadening coefficients. Optimizing these three factors with this relation map, the relative sensitivity was advanced by 2.9 times and relative broadening was reduced by 0.76 times. This model can provide a theoretical guidance for the optimization of the experimental conditions.

  11. Flow injection spectrophotometry using natural reagent from Morinda citrifolia root for determination of aluminium in tea.

    Science.gov (United States)

    Tontrong, Sopa; Khonyoung, Supada; Jakmunee, Jaroon

    2012-05-01

    A flow injection (FI) spectrophotometric method with using natural reagent extracted from Morinda citrifolia root has been developed for determination of aluminium. The extract contained anthraquinone compounds which could react with Al(3+) to form reddish complexes which had maximum absorption wavelength at 499.0nm. The extract could be used as a reagent in FI system without further purification to obtain pure compound. A sensitive method for determination of aluminium in concentration range of 0.1-1.0mgL(-1), with detection limit of 0.05mgL(-1) was achieved. Relative standard deviations of 1.2% and 1.7% were obtained for the determination of 0.1 and 0.6mgL(-1) Al(3+) (n=11). Sample throughput of 35h(-1) was achieved with the consumption of 3mL each of carrier and reagent solutions per injection. The developed method was successfully applied to tea samples, validated by the FAAS standard method. The method is simple, fast, economical and could be classified as a greener analytical method. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Method and apparatus for injecting fluid

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, W E

    1966-07-05

    A method and apparatus are described for injecting grouting material into porous, fractured, unconsolidated, or other formations, whose cohesion is to be increased and/or whose permeability is to be decreased. A tool for injecting the fluid consists of a packer and valves through which the pressurized fluid may pass from the interior of the tool to the packer to expand it. Another valve allows pressure fluid to be vented so as to allow contraction of the packer. A third valve allows a flow of pressurized flow out of the tool and into the material when a predetermined pressure within the tool has been attained. (9 claims)

  13. Linear regression analysis of potentiometric titration data for asymmetric redox reactions

    International Nuclear Information System (INIS)

    Mar'yanov, B.M.; Gavrilenko, M.A.

    1997-01-01

    A statistical method of processing the curves of potentiometric titration for homogeneous asymmetric redox reactions has been suggested. The method was tested using a model titrimetric system Mohr's salt-K 2 Cr 2 O 7 and was employed for Te determination in an individual solution, semiconductor alloy and CdTe ceramics. Random error of the equivalence point evaluation by the data of a specific titration of 0.1-0.01 M solutions does not exceed 0.3% in case of titration of 0.001 M solutions it increases up to 1.2%. The value of s r varies from 0.0006 to 0.007

  14. Flow structure of conical distributed multiple gas jets injected into a water chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jiajun; Yu, Yonggang [Nanjing University of Science and Technology, Nanjing (China)

    2017-04-15

    Based on an underwater gun firing project, a mock bullet with several holes on the head was designed and experimented to observe the combustion gas injected into a cylindrical water chamber through this mock bullet. The combustion gas jets contain one vertical central jet and 4 to 8 slant lateral jets. A high speed camera system was used to record the expansion of gas jets in the experimental study. In numerical simulations, the Euler two-fluid model and volume of fluid method were adopted to describe the gas-liquid flow. The results show the backflow zone in lateral jet is the main factor influencing the gas-liquid turbulent mixing in downstream. On cross sections, the gas volume fraction increased with time but the growth rate decreased. With a change of nozzle structure, the gas fraction was more affected than the shock structure.

  15. A transit-time flow meter for measuring milliliter per minute liquid flow

    DEFF Research Database (Denmark)

    Yang, Canqian; Kymmel, Mogens; Søeberg, Henrik

    1988-01-01

    A transit-time flow meter, using periodic temperature fluctuations as tracers, has been developed for measuring liquid flow as small as 0.1 ml/min in microchannels. By injecting square waves of heat into the liquid flow upstream with a tiny resistance wire heater, periodic temperature fluctuation....... This flow meter will be used to measure and control the small liquid flow in microchannels in flow injection analysis. Review of Scientific Instruments is copyrighted by The American Institute of Physics....... are generated downstream. The fundamental frequency phase shift of the temperature signal with respect to the square wave is found to be a linear function of the reciprocal mean velocity of the fluid. The transit-time principle enables the flow meter to have high accuracy, better than 0.2%, and good linearity...

  16. Biosensing of glucose in flow injection analysis system based on glucose oxidase-quantum dot modified pencil graphite electrode.

    Science.gov (United States)

    Sağlam, Özlem; Kızılkaya, Bayram; Uysal, Hüseyin; Dilgin, Yusuf

    2016-01-15

    A novel amperometric glucose biosensor was proposed in flow injection analysis (FIA) system using glucose oxidase (GOD) and Quantum dot (ZnS-CdS) modified Pencil Graphite Electrode (PGE). After ZnS-CdS film was electrochemically deposited onto PGE surface, GOD was immobilized on the surface of ZnS-CdS/PGE through crosslinking with chitosan (CT). A pair of well-defined reversible redox peak of GOD was observed at GOD/CT/ZnS-CdS/PGE based on enzyme electrode by direct electron transfer between the protein and electrode. Further, obtained GOD/CT/ZnS-CdS/PGE offers a disposable, low cost, selective and sensitive electrochemical biosensing of glucose in FIA system based on the decrease of the electrocatalytic response of the reduced form of GOD to dissolved oxygen. Under optimum conditions (flow rate, 1.3mL min(-1); transmission tubing length, 10cm; injection volume, 100μL; and constant applied potential, -500mV vs. Ag/AgCl), the proposed method displayed a linear response to glucose in the range of 0.01-1.0mM with detection limit of 3.0µM. The results obtained from this study would provide the basis for further development of the biosensing using PGE based FIA systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Highly selective direct determination of chlorate ions by using a newly developed potentiometric electrode based on modified smectite.

    Science.gov (United States)

    Topcu, Cihan

    2016-12-01

    A novel polyvinyl chloride membrane chlorate (ClO 3 - ) selective electrode based on modified smectite was developed for the direct determination of chlorate ions and the potentiometric performance characteristics of its were examined. The best selectivity and sensitivity for chlorate ions were obtained for the electrode membrane containing ionophore/polyvinylchloride/o-nitrophenyloctylether in composition of 12/28/60 (w/w%). The proposed electrode showed a Nernstian response toward chlorate ions at pH=7 in the concentration range of 1×10 -7 -1×10 -1 M and the limit of detection was calculated as 9×10 -8 M from the constructed response plot. The linear slope of the electrode was -61±1mVdecade -1 for chlorate activity in the mentioned linear working range. The selectivity coefficients were calculated according to both the matched potential method and the separate solution method. The calculated selectivity coefficients showed that the electrode performed excellent selectivity for chlorate ions. The potentiometric response of electrode toward chlorate ions was found to be highly reproducible. The electrode potential was stable between pH=4-10 and it had a dynamic response time of <5s. The potentiometric behavior of the electrode in partial non-aqueous medium was also investigated and the obtained results (up to 5% (v/v) alcohol) were satisfactory. The proposed electrode was used during 15 weeks without any significant change in its potential response. Additionally, the electrode was very useful in water analysis studies such as dam water, river water, tap water, and swimming pool water where the direct determination of chlorate ions was required. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Reporter-free potentiometric sensing of boronic acids and their reactions by using quaternary ammonium salt-functionalized polymeric liquid membranes.

    Science.gov (United States)

    Wang, Xuewei; Yue, Dengfeng; Lv, Enguang; Wu, Lei; Qin, Wei

    2014-02-18

    The tremendous applications of boronic acids (BAs) in chemical sensing, medical chemistry, molecular assembly, and organic synthesis lead to an urgent demand for developing effective sensing methods for BAs. This paper reports a facile and sensitive potentiometric sensor scheme for heterogeneous detection of BAs based on their unexpected potential responses on quaternary ammonium salt-doped polymeric liquid membranes. (11)B NMR data reveal that a quaternary ammonium chloride can trigger the hydrolysis of an electrically neutral BA in an aprotic solvent. Using the quaternary ammonium salt as the receptor, the BA molecules can be extracted from the sample solution into the polymeric membrane phase and undergo the concomitant hydrolysis. Such salt-triggered hydrolysis generates H(+) ions, which can be coejected into the aqueous phase with the counterions (e.g., Cl(-)) owing to their high hydrophilicities. The perturbation on the ionic partition at the sample-membrane interface changes the phase boundary potential and thus enables the potentiometric sensing of BAs. In contrast to other transduction methods for BAs, for which labeled or separate reporters are exclusively required, the present heterogeneous sensing scheme allows the direct detection of BAs without using any reporter molecules. This technique shows superior detection limits for BAs (e.g., 1.0 × 10(-6) M for phenylboronic acid) as compared to previously reported methods based on colorimetry, fluorimetry, and mass spectrometry. The proposed sensing strategy has also been successfully applied to potentiometric indication of the BA reactions with hydrogen peroxide and saccharides, which allows indirect and sensitive detection of these important species.

  19. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; del Campo, Francisco Javier; Abramova, Natalia

    2011-01-01

    This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi‐reference electrode (QRE) coupled to a solid‐state ion‐selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen‐printing...... electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 °C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open‐circuit‐potential standard deviation of ±1.2 mV over...