WorldWideScience

Sample records for filtration rate measurement

  1. Measurement of glomerular filtration rate in the conscious rat.

    Science.gov (United States)

    Pestel, Sabine; Krzykalla, Volker; Weckesser, Gerhard

    2007-01-01

    Glomerular filtration rate (GFR) is an important parameter for studying drug-induced impairments on renal function in rats. The GFR is calculated from the concentration of creatinine and blood urea nitrogen (BUN) in serum and in urine, respectively. Following current protocols serum and urine samples must be taken from the same animal. Thus, in order to determine time-dependent effects it is necessary to use for each time point one separated group of animals. We developed a statistical test which allows analyzing the GFR from two different groups of animals: one used for repeated serum and the other one used for repeated urine analysis. Serum and urine samples were taken from two different sets of rats which were otherwise treated identically, i.e. drug doses, routes of administration (per os or per inhalation) and tap water loading. For each dose group GFR mean, standard deviation and statistical analysis to identify differences between the dose groups were determined. After determination of the optimal time points for measurements, the effect on GFR of the three reference compounds, furosemide, hydrochlorothiazide and formoterol, was calculated. The results showed that the diuretic drugs furosemide and hydrochlorothiazide decreased the GFR and the antidiuretic drug formoterol increased the GFR, as counter regulation on urine loss or urine retention, respectively. A mathematical model and the corresponding algorithm were developed, which can be used to calculate the GFR, and to test for differences between groups from two separated sets of rats, one used for urine, and the other one for serum analysis. This new method has the potential to reduce the number of animals needed and to improve the quality of data generated from various groups of animals in renal function studies.

  2. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  3. Assessment of glomerular filtration rate measurement with plasma sampling: a technical review.

    Science.gov (United States)

    Murray, Anthony W; Barnfield, Mark C; Waller, Michael L; Telford, Tania; Peters, A Michael

    2013-06-01

    This article reviews available radionuclide-based techniques for glomerular filtration rate (GFR) measurement, focusing on clinical indications for GFR measurement, ideal GFR radiopharmaceutical tracer properties, and the 2 most common tracers in clinical use. Methods for full, 1-compartment, and single-sample renal clearance characterization are discussed. GFR normalization and the role of GFR measurement in chemotherapy dosing are also considered.

  4. Measurement of glomerular filtration rate by impulse synthesis: Clinical validation and optimization

    International Nuclear Information System (INIS)

    Palagi, B.; Verga, P.; Broggi, A.; Picozzi, R.; Villa, F.; Guzzini, F.; Cozzi, C.; Tomasi, A.

    1988-01-01

    Impulse synthesis is a technique which relies upon the logic of continuous infusion but extracts the clearance value from single-injection data by shifting and adding them until an asymptotic value is attained. This study has been aimed at validating and optimizing clinically the measurement of glomerular filtration rate by impulse synthesis. A single intravenous injection of 51 Cr-EDTA has been made in 32 patients and plasma activity monitored over the next 6 h. Glomerular filtration rate computed by a single-exponential fit method (GFR-SEF) has been shown to be significantly (p [de

  5. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods

    International Nuclear Information System (INIS)

    Balachandran, S.; Toguri, A.G.; Petrusick, T.W.; Abbott, L.C.

    1981-01-01

    Good correlation of glomerular filtration rate (GFR) measured isotopically from plasma disappearance of Tc-99m-DTPA (Sn) was shown with inulin clearance, creatinine clearance, and graded radionuclide imaging. The isotopic GFR is a simple, urineless technique not requiring continuous infusion that enables one to perform simultaneous renal imaging with one radiotracer

  6. Measurement of renal glomerular filtration rate using labelled substances with compartmental analysis

    International Nuclear Information System (INIS)

    Eberstadt, P.L.

    1981-10-01

    Using a model for the two-compartmental open system and experiments on animals (rabbits and dogs) as well as on human healthy volunteers, an attempt was made to study the advantages and limitations of different radionuclide methods for glomerular filtration rate determination. Labelled compounds used in different combinations were: 3 H-inulin, sup(113m)In-EDTA, 131 I-iothalamate, sup(99m)Tc-DTPA and 14 C-creatinine. The results of the study lead to some working hypotheses concerning the value of creatinine and other labelled substances in the measurement of glomerular filtration rate in clinical practice. The advantages and disadvantages of individual methods summarized in the final report are generally in agreement with the present views of many research workers. Also the hypothesis can be justified that the different labelled compounds which have been studied might be handled independently by the membranes involved but at the long run produce similar homeostatic balance

  7. Current status and methodological aspects on the measurement of glomerular filtration rate

    International Nuclear Information System (INIS)

    Froissart, M.; Hignette, C.; Kolar, P.; Prigent, A.; Paillard, M.

    1995-01-01

    Determination of the glomerular filtration rate (GFR) contribute to our understanding of kidney physiology and pathophysiology . Moreover, determination of GFR is of clinical importance in assessing the diagnosis and the progression of renal disease. The purpose of this article is to review the technical performance and results of GFR measurements, including the classical inulin clearance technique and more recent alternative clearance techniques using radioisotope-labelled filtration markers, bolus infusion and spontaneous bladder emptying. Some simplified techniques avoiding urinary collection are also described. We conclude that estimation of GFR from renal and in some cases plasmatic clearances is accurate and more convenient than the classical inulin clearance technique. Such measurements of GFR should be included both in clinical practice and clinical research. (authors). 80 refs., 5 figs., 1 tab

  8. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  9. Measured glomerular filtration rate does not improve prediction of mortality by cystatin C and creatinine.

    Science.gov (United States)

    Sundin, Per-Ola; Sjöström, Per; Jones, Ian; Olsson, Lovisa A; Udumyan, Ruzan; Grubb, Anders; Lindström, Veronica; Montgomery, Scott

    2017-04-01

    Cystatin C may add explanatory power for associations with mortality in combination with other filtration markers, possibly indicating pathways other than glomerular filtration rate (GFR). However, this has not been firmly established since interpretation of associations independent of measured GFR (mGFR) is limited by potential multicollinearity between markers of GFR. The primary aim of this study was to assess associations between cystatin C and mortality, independent of mGFR. A secondary aim was to evaluate the utility of combining cystatin C and creatinine to predict mortality risk. Cox regression was used to assess the associations of cystatin C and creatinine with mortality in 1157 individuals referred for assessment of plasma clearance of iohexol. Since cystatin C and creatinine are inversely related to mGFR, cystatin C - 1 and creatinine - 1 were used. After adjustment for mGFR, lower cystatin C - 1 (higher cystatin C concentration) and higher creatinine - 1 (lower creatinine concentration) were independently associated with increased mortality. When nested models were compared, avoiding the potential influence of multicollinearity, the independence of the associations was supported. Among models combining the markers of GFR, adjusted for demographic factors and comorbidity, cystatin C - 1 and creatinine - 1 combined explained the largest proportion of variance in associations with mortality risk ( R 2  = 0.61). Addition of mGFR did not improve the model. Our results suggest that both creatinine and cystatin C have independent associations with mortality not explained entirely by mGFR and that mGFR does not offer a more precise mortality risk assessment than these endogenous filtration markers combined. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  10. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C

    2012-03-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during biofouling studies in membrane fouling simulators (MFS). Transparent planar O 2 optodes in combination with a luminescence lifetime imaging system were used to map the two-dimensional distribution of O 2 concentrations and consumption rates inside the MFS. The O 2 distribution was indicative for biofilm development. Biofilm activity was characterized by imaging of O 2 consumption rates, where low and high activity areas could be clearly distinguished. The spatial development of O 2 consumption rates, flow channels and stagnant areas could be determined. This can be used for studies on concentration polarization, i.e. salt accumulation at the membrane surface resulting in increased salt passage and reduced water flux. The new optode-based O 2 imaging technique applied to MFS allows non-destructive and spatially resolved quantitative biological activity measurements (BAM) for on-site biofouling diagnosis and laboratory studies. The following set of complementary tools is now available to study development and control of biofouling in membrane systems: (i) MFS, (ii) sensitive pressure drop measurement, (iii) magnetic resonance imaging, (iv) numerical modelling, and (v) biological activity measurement based on O 2 imaging methodology. © 2011 Elsevier B.V.

  11. Transcutaneous measurement of glomerular filtration rate in small rodents: through the skin for the win?

    Science.gov (United States)

    Ellery, Stacey J; Cai, Xiaochu; Walker, David D; Dickinson, Hayley; Kett, Michelle M

    2015-03-01

    Rodent models of renal physiology and pathology are crucial to our understanding of the molecular, histological and functional sequelae that contribute to kidney diseases. One of the most important measures of renal function is glomerular filtration rate (GFR). While the accurate determination of GFR is pivotal to understanding the progression of disease and/or the benefits of treatment strategies, in rodents the conventional methods for assessment of GFR are inconvenient and cumbersome, not the least because they involve stress and often anaesthesia. The legitimacy of assay-based assessment of plasma and urine markers of GFR in mice has also been heavily scrutinized for their insensitivity to minor declines in GFR and inaccurate detection of renal biomarkers. While infusion-based clearance methods of GFR assessment are thus the gold standard in terms of accuracy, they are limited by the fact that they are primarily non-recovery procedures. This presents a dilemma when trying to document the progression of renal disease, as these measures cannot be taken in the same experimental subject. Here we review a technique of transcutaneous measurement of fluorescein isothiocyanate-labelled sinistrin to calculate GFR in small rodents, using a non-invasive clearance device (NIC-Kidney Device). This is a recently validated non-invasive technique for measuring GFR in small rodents that allows for the real-time measurement of GFR in conscious animals, without the need for plasma and urine assays. © 2014 Asian Pacific Society of Nephrology.

  12. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  13. Radioisotopic measurement of glomerular filtration rate in severe chronic renal failure

    International Nuclear Information System (INIS)

    LaFrance, N.D.; Drew, H.H.; Walser, M.

    1988-01-01

    In order to determine the best method for routine measurement of glomerular filtration rate (GFR) in severe renal failure, we compared simultaneously the urinary clearances of [/sup 99m/Tc] diethylenetriaminepentaacetic acid (DTPA) (UD), [ 125 I]iothalamate (UI), 24-hr creatinine clearance (UC) and plasma clearance of [/sup 99m/Tc]DTPA (PD), based on three plasma samples. In 60 studies in 22 patients with serum creatinine values of 2 to 8 mg/dl, UD and UI were almost identical: UD = 0.358 +/- 0.976 UI +/- 0.87 ml/min, r = 0.990. However, PD overestimated UD by a large and variable extent: PD = 11.3 +/- 0.843 UD +/- 5.5 ml/min, r = 0.694, and was inconsistent in sequential measurements in individual patients. UC also overestimated urinary isotope clearance: UC = 4.2 + 0.95 UI +/- 3.9 ml/min, r = 0.865. Sequential measurements of GFR in five patients with severe but stable renal failure (mean GFR 5.9 ml/min) showed an average standard deviation of only 0.83 ml/min. Thus both UD and UI appear to be reliable and precise measures of GFR in severe renal failure

  14. Comparative study between in Vivo and Vitro radionuclide technique in measurement of Glomerular filtration rate

    International Nuclear Information System (INIS)

    Ziada, G.; Moustafa, H.; Elhaddad, SH.; Taalab, KH.

    1995-01-01

    Fifty patients were referred to nuclear medicine department in NEMROCK center for measurement of glomerular filtration rate (GFR). The group included 34 males and 16 females with a mean age of 38.3 ± 10.7 years. Estimation of GFR was done using 111-185 mBq of 99m Tc-DTPA with data collected on 128 x 128 matrix on IDAC computer every 15 seconds with calculation of renal uptake and GFR applying Gates method. 72 hours, a dose 3.7 mBq of 51 Cr-EDTA with 2 blood samples taken at 120, 240 minutes with estimation of plasma clearance using Russel et al., method (1985). The mean clearance of 51 Cr-EDTA was 79.61±22.4 ml/min compared to 84.34±26.3 ml/min. Using direct scintigraphic method with positive correlation using regression analysis (r=0.96). Also, both 51 Cr-EDTA and in vivo 99m Tc-DTPA were positively correlated with creatinine clearance (r=0.87 and 0.91 respectively). A modified regression formulas was used for correction of the results of 99m Tc-DTPA values GFR ( 99m Tc-DTPA) x 0.81 + 11 ± 6.4 ml/min. 4 figs., 1 tab

  15. Comparative study between in Vivo and Vitro radionuclide technique in measurement of Glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G; Moustafa, H; Elhaddad, SH; Taalab, KH [Nuclear medicine department, Faculty of medicine, Cairo university, Cairo, (Egypt)

    1995-10-01

    Fifty patients were referred to nuclear medicine department in NEMROCK center for measurement of glomerular filtration rate (GFR). The group included 34 males and 16 females with a mean age of 38.3 {+-} 10.7 years. Estimation of GFR was done using 111-185 mBq of {sup 99m} Tc-DTPA with data collected on 128 x 128 matrix on IDAC computer every 15 seconds with calculation of renal uptake and GFR applying Gates method. 72 hours, a dose 3.7 mBq of {sup 51} Cr-EDTA with 2 blood samples taken at 120, 240 minutes with estimation of plasma clearance using Russel et al., method (1985). The mean clearance of {sup 51} Cr-EDTA was 79.61{+-}22.4 ml/min compared to 84.34{+-}26.3 ml/min. Using direct scintigraphic method with positive correlation using regression analysis (r=0.96). Also, both {sup 51} Cr-EDTA and in vivo {sup 99m} Tc-DTPA were positively correlated with creatinine clearance (r=0.87 and 0.91 respectively). A modified regression formulas was used for correction of the results of {sup 99m} Tc-DTPA values GFR ({sup 99m}Tc-DTPA) x 0.81 + 11 {+-} 6.4 ml/min. 4 figs., 1 tab.

  16. Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.

    Science.gov (United States)

    Jiang, Kai; Tang, Hui; Mishra, Prasanna K; Macura, Slobodan I; Lerman, Lilach O

    2018-06-01

    To develop and validate a method for measuring murine single-kidney glomerular filtration rate (GFR) using dynamic contrast-enhanced MRI (DCE-MRI). This prospective study was approved by the Institutional Animal Care and Use Committee. A fast longitudinal relaxation time (T 1 ) measurement method was implemented to capture gadolinium dynamics (1 s/scan), and a modified two-compartment model was developed to quantify GFR as well as renal perfusion using 16.4T MRI in mice 2 weeks after unilateral renal artery stenosis (RAS, n = 6) or sham (n = 8) surgeries. This approach was validated by comparing model-derived GFR and perfusion to those obtained by fluorescein isothiocyanante (FITC)-inulin clearance and arterial spin labeling (ASL), respectively, using the Pearson's and Spearman's rank correlations and Bland-Altman analysis. The compartmental model provided a good fitting to measured gadolinium dynamics in both normal and RAS kidneys. The proposed DCE-MRI method offered assessment of single-kidney GFR and perfusion, comparable to the FITC-inulin clearance (Pearson's correlation coefficient r = 0.95 and Spearman's correlation coefficient ρ = 0.94, P < 0.0001, and mean difference -7.0 ± 11.0 μL/min) and ASL (r = 0.92 and ρ = 0.84, P < 0.0001, and mean difference 4.4 ± 66.1 mL/100 g/min) methods. The proposed DCE-MRI method may be useful for reliable noninvasive measurements of single-kidney GFR and perfusion in mice. Magn Reson Med 79:2935-2943, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Measurement of glomerular filtration rate using inulin prepared from Vernonia herbacea, a Brazilian native species.

    Science.gov (United States)

    Dias-Tagliacozzo, G M; Dietrich, S M; Mello-Aires, M

    1996-10-01

    Vernonia herbacea (Vell.) Rusby (Asteraceae) is a perennial herb native to the cerrado vegetation of tropical areas in Brazil, which accumulates inulin in the underground reserve organs. The aim of this paper was to determine whether the inulin extracted from V. herbacea could replace commercial inulin for the measurement of glomerular filtration rate (GFR). Underground organs of vegetative plants were collected from a preserved area of the Brazilian cerrado. The inulin fraction utilized was obtained by ethanol precipitation after discarding the high molecular mass fructans in the freeze-thawing precipitate. GFR was determined in male Wistar rats anesthetized with inactin (100 mg/kg), which received intravenously commercial inulin obtained from Dahlia sp (Sigma) or Vernonia herbacea inulin (30 mg/100 g) as a priming dose and 0.05 mg min-1 100 g-1 as a sustaining dose in isotonic saline at the rate of 0/055 ml/min. Clearance was determined during 3 periods, with urine collected from the bladder and blood from the carotid artery. There was no significant difference in the GFR measured by clearance in inulin from both sources even when the plasma concentration of inulin from V. herbacea was doubled. The mean arterial pressure did not vary after the application of both inulins, indicating that they do not produce systemic side effects. The filtered load and the excreted amount of inulin from V. herbacea were equal, showing that the substance is not influenced by tubular function. These results demonstrate that the inulin from V. herbacea can substitute for imported inulin for the determination of GFR and in experiments of kidney microperfusion as a marker of tubular water reabsorption.

  18. Monitoring renal function in children with Fabry disease: comparisons of measured and creatinine-based estimated glomerular filtration rate

    NARCIS (Netherlands)

    Tøndel, Camilla; Ramaswami, Uma; Aakre, Kristin Moberg; Wijburg, Frits; Bouwman, Machtelt; Svarstad, Einar

    2010-01-01

    Studies on renal function in children with Fabry disease have mainly been done using estimated creatinine-based glomerular filtration rate (GFR). The aim of this study was to compare estimated creatinine-based GFR (eGFR) with measured GFR (mGFR) in children with Fabry disease and normal renal

  19. Transcutaneous glomerular filtration rate measurement in a canine animal model of chronic kidney disease.

    Science.gov (United States)

    Mondritzki, Thomas; Steinbach, Sarah M L; Boehme, Philip; Hoffmann, Jessica; Kullmann, Maximilian; Schock-Kusch, Daniel; Vogel, Julia; Kolkhof, Peter; Sandner, Peter; Bischoff, Erwin; Hüser, Jörg; Dinh, Wilfried; Truebel, Hubert

    Quantitative assessment of renal function by measurement of glomerular filtration rate (GFR) is an important part of safety and efficacy evaluation in preclinical drug development. Existing methods are often time consuming, imprecise and associated with animal burden. Here we describe the comparison between GFR determinations with sinistrin (PS-GFR) and fluorescence-labelled sinistrin-application and its transcutaneous detection (TD-GFR) in a large animal model of chronic kidney disease (CKD). TD-GFR measurements compared to a standard method using i.v. sinistrin were performed in a canine model. Animals were treated with one-sided renal wrapping (RW) followed by renal artery occlusion (RO). Biomarker and remote hemodynamic measurements were performed. Plasma sinistrin in comparison to transcutaneous derived GFR data were determined during healthy conditions, after RW and RW+RO. RW alone did not led to any significant changes in renal function, neither with PS-GFR nor TD-GFR. Additional RO showed a rise in blood pressure (+68.0mmHg), plasma urea (+28.8mmol/l), creatinine (+224,4μmol/l) and symmetric dimethylarginine (SDMA™; +12.6μg/dl). Plasma sinistrin derived data confirmed the expected drop (-44.7%, p<0.0001) in GFR. The calculated transcutaneous determined Fluorescein Isothiocyanate (FITC)-sinistrin GFR showed no differences to plasma sinistrin GFR at all times. Both methods were equaly sensitive to diagnose renal dysfunction in the affected animals. Renal function assessment using TD-GFR is a valid method to improve preclinical drug discovery and development. Furthermore, TD-GFR method offers advantages in terms of reduced need for blood sampling and thus decreasing animal burden compared to standard procedures. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Measured glomerular filtration rate at dialysis initiation and clinical outcomes of Indian peritoneal dialysis patients

    Directory of Open Access Journals (Sweden)

    N Prasad

    2017-01-01

    Full Text Available The optimal time for dialysis initiation remains controversial. Studies have failed to show better outcomes with early initiation of hemodialysis; even a few had shown increased adverse outcomes including poorer survival. Few studies have examined the same in patients on peritoneal dialysis (PD. Measured glomerular filtration rate (mGFR not creatinine-based estimated GFR is recommended as the measure of kidney function in end-stage renal disease (ESRD patients. The objective of this observational study was to compare the outcomes of Indian patients initiated on PD with different residual renal function (RRF as measured by 24-h urinary clearance method. A total of 352 incident patients starting on chronic ambulatory PD as the first modality of renal replacement therapy were followed prospectively. Patients were categorized into three groups as per mGFR at the initiation of PD (≤5, >5–10, and> 10 ml/min/1.73 m2. Patient survival and technique survival were compared among the three groups. Patients with GFR of ≤5 ml/min/1.73 m2 (hazard ratio [HR] - 3.42, 95% confidence interval [CI] - 1.85–6.30, P = 0.000 and> 5–10 ml/min/1.73 m2 (HR - 2.16, 95% CI - 1.26–3.71, P = 0.005 had higher risk of mortality as compared to those with GFR of> 10 ml/min/1.73 m2. Each increment of 1 ml/min/1.73 m2 in baseline GFR was associated with 10% reduced risk of death (HR - 0.90, 95% CI - 0.85–0.96, P = 0.002. Technique survival was poor in those with an initial mGFR of ≤5 ml/min/1.73 m2 as compared to other categories. RRF at the initiation was also an important factor predicting nutritional status at 1 year of follow-up. To conclude, initiation of PD at a lower baseline mGFR is associated with poorer patient and technique survival in Indian ESRD patients.

  1. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C; Staal, Marc J.; Kü hl, Michael; van Loosdrecht, Mark C.M.; Vrouwenvelder, Johannes S.

    2012-01-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during

  2. Comparison of inulin, iothalamate, and /sup 99m/Tc-DTPA for measurement of glomerular filtration rate

    International Nuclear Information System (INIS)

    Barbour, G.L.; Crumb, C.K.; Boyd, C.M.; Reeves, R.D.; Rastogi, S.P.; Patterson, R.M.

    1976-01-01

    Clearances of inulin, 125 I-iothalamate, and /sup 99m/Tc-Sn-DTPA were measured simultaneously in five mongrel dogs exhibiting a wide range of glomerular filtration rates (GFR). Standard constant-infusion inulin clearance was compared to radionuclide clearances after subcutaneous injection of the emitters mixed with aqueous epinephrine. All three substances were found to have virtually identical clearances. The accuracy, accessibility, low cost, low radiation hazard, and short half-life of /sup 99m/Tc-Sn-DTPA make it an excellent substance for measuring GFR. The subcutaneous technique offers an accuracy comparable to the more difficult constant-infusion method

  3. Determination of representative renal depth for accurate attenuation corred in measurement of glomerular filtration rate in transplanted kidney

    International Nuclear Information System (INIS)

    Oh, Soon Nam; Kim, Sung Hoon; Rha, Sung Eun; Chung, Yong An; Yoo, Ie Ryung; Sohn, Hyung Sun; Lee, Sung Young; Chung, Soo Kyo

    2002-01-01

    To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured DFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depth under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are 4.09±0.65 cm in men, and 4.24±0.78 cm in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply

  4. Decline in 51Cr-labelled EDTA measured glomerular filtration rate following lung transplantation

    DEFF Research Database (Denmark)

    Hornum, Mads; Burton, Christopher M; Iversen, Martin

    2007-01-01

    -labelled EDTA clearance (mGFR) and the Cockcroft-Gault calculated clearance (cGFR). Trough cyclosporine levels (C0) and demographic and transplant information were also included in the analysis. RESULTS: A total of 66959 C0 and serum creatinine and 1945 mGFR measurements pertaining to 383 patients were included...... in the analysis. Pre-transplant mGFR was significantly lower with respect to recipient age over 60 years; and patients with a referral diagnosis of pulmonary hypertension had a lower mGFR and higher baseline serum creatinine levels than patients with emphysematous disease (P ... correlations between log(10) mean interval serum creatinine and log(2) mGFR at all time points pre- and post-transplantation (P

  5. Measurement of glomerular filtration rate using technetium-99m-DTPA and the gamma camera: A comparison of methods

    International Nuclear Information System (INIS)

    Russell, C.D.; Bischoff, P.G.; Kontzen, F.; Rowell, K.L.; Yester, M.V.; Lloyd, L.K.; Tauxe, W.N.; Dubovsky, E.V.

    1984-01-01

    A variety of methods has been proposed to estimate glomerular filtration rate (GFR) from renal uptake of Tc-99m-DTPA using a gamma camera. To compare alternative methods, the authors have calculated GFR in several different ways from measurements in 33 patients, and compared the results with an independent GFR measurement based on 8-point plasma clearance of Yb-169-DTPA. The best agreement was obtained using an algorithm that has not been described previously. This was a modification of a method used previously in which correction was made for overlap of kidneys by liver and spleen. The correlation coefficient was 0.958 and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with correlation coefficient 0.866 and residual standard deviation 21.1 ml/min. The accuracy of these methods was comparable to that reported for the creatinine clearance, the most commonly used estimate of GFR in current clinical practice

  6. Decline in measured glomerular filtration rate is associated with a decrease in endurance, strength, balance and fine motor skills.

    Science.gov (United States)

    Hellberg, Matthias; Höglund, Peter; Svensson, Philippa; Abdulahi, Huda; Clyne, Naomi

    2017-07-01

    Physical performance in chronic kidney disease affects morbidity and mortality. The aim was to find out which measures of physical performance are important in chronic kidney disease (CKD) and if there are associations with declining measured glomerular filtration rate (GFR). Endurance was assessed by 6 min walk test (6-MWT) and stair climbing, muscular endurance by 30 s sit to stand, heel rises and toe lifts, strength by quadriceps- and handgrip-strength, balance by functional reach and Berg's balance scale, and fine motor skills by Moberg's picking-up test. GFR was measured by Iohexol clearance. The study comprised 101 patients with CKD 3b-5 not started dialysis, 40 women and 61 men, with a mean age of 67 ± 13 (range: 22 - 87) years. All measures of physical performance were impaired. A decrease in GFR of 10 mL/min per 1.73 m 2 corresponded to a 35 metre shorter walking distance in the 6-MWT. Multivariable linear regression analysis showed significant relationships between decline in GFR and the 6-MWT (P = 0.04), isometric quadriceps strength left (P = 0.04), balance measured as functional reach (P = 0.02) and fine motor skills in the left hand as measured by Moberg's picking-up test (P = 0.01), respectively, after sex, age, comorbidity and the interaction between sex and age had been taken into account. Endurance, muscular endurance, strength, balance and fine motor skills were impaired in patients with CKD 3b-5. Walking capacity, isometric quadriceps strength, balance, and fine motor skills were associated with declining GFR. The left extremities were more susceptible to GFR, ageing and comorbidities and seem thus to be more sensitive. © 2016 Asian Pacific Society of Nephrology.

  7. Reliability of single kidney glomerular filtration rate measured by a 99mTc-DTPA gamma camera technique

    International Nuclear Information System (INIS)

    Rehling, M.; Moller, M.L.; Jensen, J.J.; Thamdrup, B.; Lund, J.O.; Trap-Jensen, J.

    1986-01-01

    The reliability of a previously published method for determination of single kidney glomerular filtration rate (SKGFR) by means of technetium-99m-diethylenetriaminepenta-acetate (99mTc-DTPA) gamma camera renography was evaluated. The day-to-day variation in the calculated SKGFR values was earlier found to be 8.8%. The technique was compared to the simultaneously measured renal clearance of inulin in 19 unilaterally nephrectomized patients with GFR varying from 11 to 76 ml/min. The regression line (y = 1.04 X -2.5) did not differ significantly from the line of identity. The standard error of estimate was 4.3 ml/min. In 17 patients the inter- and intraobserver variation of the calculated SKGFR values was 1.2 ml/min and 1.3 ml/min, respectively. In 21 of 25 healthy subjects studied (age range 27-29 years), total GFR calculated from the renograms was within an established age-dependent normal range of GFR

  8. Development of formulas for the estimation of renal depth and application in the measurement of glomerular filtration rate in Koreans

    International Nuclear Information System (INIS)

    Yoo, Ie Ryung; Kim, Sung Hoon; Chung, Yong An

    2000-01-01

    There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F=167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the men (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height) +0.002 (age) +2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for for MLK,12.936 (weight/height)+0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately

  9. Improved measurement of the glomerular filtration rate from Tc-99m DTPA scintigraphy in patients following nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-il; Ha, Seunggyun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); So, Young [Konkuk University School of Medicine, Department of Nuclear Medicine, Chungju (Korea, Republic of); Lee, Won Woo [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); Byun, Seok-Soo [Seoul National University College of Medicine, Department of Urology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kim, Sang Eun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of)

    2014-02-15

    We aimed to improve Tc-99m DTPA glomerular filtration rate (GFR) scintigraphy (Gates' method) in a prospective study using Cr-51 EDTA GFR test as a gold standard. Fifty-seven Tc-99m DTPA GFR scintigrams in 45 subjects (male/female = 33:12, age = 45.9 ± 17.6 years, 14 healthy volunteers and 31 nephrectomised patients) were compared using Cr-51 EDTA GFR tests. Using the %renal uptake of Tc-99m DTPA and Cr-51 EDTA GFR, a revised equation for GFR was established through linear regression analysis. The revised equation for improved GFR was GFR(mL/min) = (%renal uptake x 11.7773) - 0.7354. Gates' original GFRs (70.1 ± 20.5 mL/min/1.73 m{sup 2}) were significantly lower than Cr-51 EDTA GFRs (97.0 ± 31.9 mL/min/1.73 m{sup 2}; P < 0.0001), but the improved GFRs (98.0 ± 26.3 mL/min/1.73 m{sup 2}) were not different from (P = 0.7360) and had a significant correlation with (r = 0.73, P < 0.0001) the Cr-51 EDTA GFRs. The revised GFR equation effectively demonstrated perioperative GFR changes in kidneys that were operated on and the contralateral kidneys at 3 and 6 months post-partial nephrectomy (n = 25). GFR measurement using Tc-99m DTPA scintigraphy could be significantly improved by a revised equation derived from the comparison with Cr-51 EDTA GFR. (orig.)

  10. Glomerular filtration rate measured by {sup 51}Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit, E-mail: annaalice100@yahoo.com.b [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Dept. de Neurologia

    2010-07-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ({sup 51}Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using {sup 51}Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ({sup 51}Cr-EDTA) and {sup 99m}Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6+-21.8 ml/kg/1.73 m{sup 2} in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1+-28.7 ml/kg/1.73m{sup 2} in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6+-14.8 ml/kg/1.73m{sup 2}, p=0.001) and an insignificant change in the group without RAS (to 62.2+-23.6 ml/kg/1.73m{sup 2}, p=0.68). Scintigraphy with technetium-99m dimercapto

  11. Glomerular filtration rate measured by 51Cr-EDTA clearance: evaluation of captopril-induced changes in hypertensive patients with and without renal artery stenosis

    International Nuclear Information System (INIS)

    Chaves, Anna Alice Rolim; Buchpiguel, Carlos Alberto; Praxedes, Jose Nery; Bortolotto, Luiz Aparecido; Sapienza, Marcelo Tatit

    2010-01-01

    Introduction: renal artery stenosis can lead to renovascular hypertension; however, the detection of stenosis alone does not guarantee the presence of renovascular hypertension. Renovascular hypertension depends on activation of the renin-angiotensin system, which can be detected by functional tests such as captopril renal scintigraphy. A method that allows direct measurement of the baseline and post-captopril glomerular filtration rate using chromium-51 labeled ethylenediamine tetraacetic acid ( 51 Cr-EDTA) could add valuable information to the investigation of hypertensive patients with renal artery stenosis. The purposes of this study were to create a protocol to measure the baseline and post-captopril glomerular filtration rate using 51 Cr-EDTA, and to verify whether changes in the glomerular filtration rate permit differentiation between hypertensive patients with and without renal artery stenosis. Methods: this prospective study included 41 consecutive patients with poorly controlled severe hypertension. All patients had undergone a radiological investigation of renal artery stenosis within the month prior to their inclusion. The patients were divided into two groups: patients with (n=21) and without renal artery stenosis, (n=20). In vitro glomerular filtration rate analysis ( 51 Cr-EDTA) and 99m Tc-DMSA scintigraphy were performed before and after captopril administration in all patients. Results: the mean baseline glomerular filtration rate was 48.6±21.8 ml/kg/1.73 m 2 in the group with renal artery stenosis, which was significantly lower than the GFR of 65.1±28.7 ml/kg/1.73m 2 in the group without renal artery stenosis (p=0.04). Captopril induced a significant reduction of the glomerular filtration rate in the group with renal artery stenosis (to 32.6±14.8 ml/kg/1.73m 2 , p=0.001) and an insignificant change in the group without RAS (to 62.2±23.6 ml/kg/1.73m 2 , p=0.68). Scintigraphy with technetium-99m dimercapto-succinic acid (DMSA) did not show

  12. Estimating Glomerular Filtration Rate in Older People

    Directory of Open Access Journals (Sweden)

    Sabrina Garasto

    2014-01-01

    Full Text Available We aimed at reviewing age-related changes in kidney structure and function, methods for estimating kidney function, and impact of reduced kidney function on geriatric outcomes, as well as the reliability and applicability of equations for estimating glomerular filtration rate (eGFR in older patients. CKD is associated with different comorbidities and adverse outcomes such as disability and premature death in older populations. Creatinine clearance and other methods for estimating kidney function are not easy to apply in older subjects. Thus, an accurate and reliable method for calculating eGFR would be highly desirable for early detection and management of CKD in this vulnerable population. Equations based on serum creatinine, age, race, and gender have been widely used. However, these equations have their own limitations, and no equation seems better than the other ones in older people. New equations specifically developed for use in older populations, especially those based on serum cystatin C, hold promises. However, further studies are needed to definitely accept them as the reference method to estimate kidney function in older patients in the clinical setting.

  13. Measurement of glomerular filtration rate (GFR) with 99mTc-DTPA and semiconductors minidetectors: further validation of the method

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Muehlbauer, J.; Schrott, K.H.; Wolf, F.

    1982-01-01

    A technique measuring external radiation with semiconductor minidetectors (SCM) by use of a portable solid state memory after bolus injection of 1mCi 99mTc-DTPA is described. The correlation of the calculated clearances to plasma creatinine levels and to endogenous creatinine clearance as well is satisfactory. This new technique is compared with a standard steady state technique (GFR-SS) using 51 Cr-EDTA. GFR-SCM is strongly correlated to GFR-SS as standard method, therefore the data provides substantial evidence that GFR-SCM is a reliable method of GFR measurement. The advantages are: fast availability of the test result especially when calculated by use of a minicomputer; ease of performance in routine work; convenience for the patient without need of compliance and low costs for the detector system

  14. Simple method for the estimation of glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Groth, T [Group for Biomedical Informatics, Uppsala Univ. Data Center, Uppsala (Sweden); Tengstroem, B [District General Hospital, Skoevde (Sweden)

    1977-02-01

    A simple method is presented for indirect estimation of the glomerular filtration rate from two venous blood samples, drawn after a single injection of a small dose of (/sup 125/I)sodium iothalamate (10 ..mu..Ci). The method does not require exact dosage, as the first sample, taken after a few minutes (t=5 min) after injection, is used to normilize the value of the second sample, which should be taken in between 2 to 4 h after injection. The glomerular filtration rate, as measured by standard insulin clearance, may then be predicted from the logarithm of the normalized value and linear regression formulas with a standard error of estimate of the order of 1 to 2 ml/min/1.73 m/sup 2/. The slope-intercept method for direct estimation of glomerular filtration rate is also evaluated and found to significantly underestimate standard insulin clearance. The normalized 'single-point' method is concluded to be superior to the slope-intercept method and more sophisticated methods using curve fitting technique, with regard to predictive force and clinical applicability.

  15. Mercaptoacetyltriglycine-3 renogram is not superior to estimated glomerular filtration rate measurement for the prediction of long-term renal function after nephrectomy

    International Nuclear Information System (INIS)

    Kanamaru, Hiroshi; Yamamoto, Masakazu; Nagahama, Kanji

    2011-01-01

    The objective of this study was to evaluate the clinical usefulness of effective renal plasma flow (ERPF) measured using preoperative mercaptoacetyltriglycine-3 (MAG3) renogram for the prediction of chronic renal insufficiency after nephrectomy. A total of 47 patients underwent preoperative MAG3 renal scintigraphy and subsequent unilateral nephrectomy. Correlations between the 5-year postoperative estimated glomerular filtration rate (eGFR) and the preoperative ERPF of the contralateral kidney (cERPF), ERPF of the diseased kidney (dERPF), total ERPF (tERPF), cERPF to dERPF ratio, serum creatinine (sCr) level, eGFR, as well as the influence of preoperative comorbidities (diabetes, hypertension) on the postoperative eGFR, were evaluated with both univariate and multivariate analyses. Multiple linear regression analysis showed that preoperative cERPF significantly correlated with postoperative eGFR. However, a much stronger correlation was observed between the preoperative and postoperative eGFR. Multiple logistic regression analysis showed that only preoperative eGFR was a significant predicator of the development of advanced-stage chronic kidney disease (CKD). Preoperative MAG3 renogram is not superior to eGFR measurement as a prognostic indicator of long-term renal function after unilateral nephrectomy. (author)

  16. Analyse of influence elements in the process of dynamic renal imaging to measure glomerular filtration rate and effective renal plasma flow in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Yao Lixin; Li Zuofei; Liu Bo; Guo Leiming

    2010-01-01

    Objective: To detect the changes and clinical influence elements of radionuclide renal dynamic imaging to measure glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in patients with type 2 diabetes mellitus (T2DM). Methods: One hundred and eight patients with T 2 DM were divided into 4 groups according to the values of urinary albumin excretion rate (UAER): Group I: UAER -1 , 31 cases. Group II: UAER 20∼200μg·min -1 , 28 cases. Group III: UAER >200μg·min -1 , serum creatinine(SCr) 200μg·min -1 , SCr≥ 105μmol/L, 23 cases. 99 Tc m -diethylenetriamine pentaacetic acid and 99 Tc m -ethylenedicysteine renal dynamic imaging were performed in all patients. GFR, ERPF and renogram were derived simultaneously. The levels of blood creatinine, blood urea nitrogen, urine albumin, blood press, fasting blood insulin, glycosylated hemoglobin, fasting blood glucousewere measured in the four groups. Results: With the evolvement of diabetes nephropathy (DN), UAERs were gradually ascended and the values of GFR and ERPF was gradually descended, the former offered remarkable inverse correlation with the two latters (r 1 = -0.497, P 2 =-0.215, P 1 =1.8, t 2 =2.1, t 3 =1.9, P 4 =3.2, P<0.01). Multielement stepwise regression analyses assumed that age, systolic pressure, glycosylated hemoglobin and insulin resistance index offered inverse correlation with GFR and ERPF (coefficient of regression factor: -0.507, -0.874, -0.528, -0.587, -0.336, -0.697, -0.348, -0.371, P<0.01). Conclusion: GFR and ERPF were sensitive index reflecting the changes of DN.Hypertension and insulin resistance were independence risk factors to make the value of GFR and ERPF decreased in patients with DN. (authors)

  17. Metabolic syndrome but not obesity measures are risk factors for accelerated age-related glomerular filtration rate decline in the general population.

    Science.gov (United States)

    Stefansson, Vidar T N; Schei, Jørgen; Solbu, Marit D; Jenssen, Trond G; Melsom, Toralf; Eriksen, Bjørn O

    2018-05-01

    Rapid age-related glomerular filtration rate (GFR) decline increases the risk of end-stage renal disease, and a low GFR increases the risk of mortality and cardiovascular disease. High body mass index and the metabolic syndrome are well-known risk factors for patients with advanced chronic kidney disease, but their role in accelerating age-related GFR decline independent of cardiovascular disease, hypertension and diabetes is not adequately understood. We studied body mass index, waist circumference, waist-hip ratio and metabolic syndrome as risk factors for accelerated GFR decline in 1261 middle-aged people representative of the general population without diabetes, cardiovascular disease or kidney disease. GFR was measured as iohexol clearance at baseline and repeated after a median of 5.6 years. Metabolic syndrome was defined as fulfilling three out of five criteria, based on waist circumference, blood pressure, glucose, high-density lipoprotein cholesterol and triglycerides. The mean GFR decline rate was 0.95 ml/min/year. Neither the body mass index, waist circumference nor waist-hip ratio predicted statistically significant changes in age-related GFR decline, but individuals with baseline metabolic syndrome had a significant mean of 0.30 ml/min/year faster decline than individuals without metabolic syndrome in a multivariable adjusted linear regression model. This association was mainly driven by the triglyceride criterion of metabolic syndrome, which was associated with a significant 0.36 ml/min/year faster decline when analyzed separately. Results differed significantly when GFR was estimated using creatinine and/or cystatin C. Thus, metabolic syndrome, but not the body mass index, waist circumference or waist-hip ratio, is an independent risk factor for accelerated age-related GFR decline in the general population. Copyright © 2017 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  18. Indexing Glomerular Filtration Rate to Body Surface Area

    DEFF Research Database (Denmark)

    Redal-Baigorri, Belén; Rasmussen, Knud; Heaf, James Goya

    2014-01-01

    BACKGROUND: Kidney function is mostly expressed in terms of glomerular filtration rate (GFR). A common feature is the expression as ml/min per 1.73 m(2) , which represents the adjustment of the individual kidney function to a standard body surface area (BSA) to allow comparison between individuals....... We investigated the impact of indexing GFR to BSA in cancer patients, as this BSA indexation might affect the reported individual kidney function. METHODS: Cross-sectional study of 895 adults who had their kidney function measured with (51) chrome ethylene diamine tetraacetic acid. Mean values of BSA...

  19. Correlation of glomerular filtration rate measurement using Tc-99m DTPA with cystatin-C levels and creatinine clearance for staging of chronic kidney disease

    International Nuclear Information System (INIS)

    Elliyanti, A.; Iskandar, Azmi S.

    2007-01-01

    Full text: The presence of Chronic Kidney Disease (CKD) was established based on kidney damage presence and the level of kidney function through Glomerular filtration rate (GFR). It was also recognized that renal scintigraphy (renogram) using TC-99m DTPA (diethylenetriamine pentacetic acid) has advantages in the measurement of GFR. Recently, serum Cystatin-C is proposed as the new marker of GFR. The aim of this study is to find out the correlation of GFR, derived from renogram, with Cystatin- C levels and Creatinine Clearance (CC) in CKD. Material and Methods: A total of 30 subjects (age mean is 60.8 years, 21 males and 9 females) were enrolled in this study with diagnosis stage 2 of CKD. CKD staging was determined by Cockroft-Gault (CG) equation, taking into account the serum creatinine. Renogram was performed using a single head camera with IV administration of 5 mCi DTPA. Cystatin-C and creatinine clearance (24-hours urine samples) were include in this study. Results: The mean GFR of renogram, Cystatin-C, CC and CG are 64.96 ml/min/1.73m2 (SD 28.047), 53.37 ml/min/1.73m2 (SD 21.29), 58.09 ml/min/1.73m2 (SD 35.45), 46.00 ml/min/1.73m2 (SD 12.06) respectively. There is better correlation between renogram and Cystatin-C (r=0.585, p0.0007) compared renogram and CC (r=0.388, p=0.03) or renogram and CG (r=-0.029, p=0.87). Conclusion: Cystatin-C shows better indicator of GFR than CC and CG. Serum creatinine concentration alone should not be used to assess the level of kidney function in the staging of CKD. (author)

  20. Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates’ method in voluntary kidney donors and renal transplant recipients

    International Nuclear Information System (INIS)

    Hephzibah, Julie; Shanthly, Nylla; Oommen, Regi

    2013-01-01

    There are numerous methods for calculation of glomerular filtration rate (GFR), which is a crucial measurement to identify patients with renal disease. The aim of this study is to compare four different methods of GFR calculation. Clinical setup, prospective study. Data was collected from routine renal scans done for voluntary kidney donors (VKD) or renal transplant recipients 6 months after transplantation. Following technetium-99m diethylene triamine penta acetic acid injection, venous blood samples were collected from contralateral arm at 120, 180, and 240 min through an indwelling venous cannula and direct collection by syringe. A total volume of 1 ml of plasma from each sample and standards were counted in an automatic gamma counter for 1 min. Blood samples taken at 120 min and 240 min were used for double plasma sample method (DPSM) and a sample taken at 180 min for single plasma sample method (SPSM). Russell's formulae for SPSM and DPSM were used for GFR estimation. Gates’ method GFR was calculated by vendor provided software. Correlation analysis was performed using Pearson's correlation test. SPSM correlated well with DPSM. GFR value in healthy potential kidney donors has a significant role in the selection of donors. The mean GFR ± (standard deviation) in VKD using SPSM, DPSM, camera depth method and Cockroft Gault method was 134.6 (25.9), 137.5 (42.4), 98.6 (15.9), 83.5 (21.1) respectively. Gates’ GFR calculation did not correlate well with plasma sampling method. Calculation of GFR plays a vital role in the management of renal patients, hence it was noted that Gates GFR may not be a reliable method of calculation. SPSM was more reliable. DPSM is reliable but cumbersome. It is difficult to accurately calculate GFR without a gold standard

  1. The clinical significance of glomerular filtration rate measured by 99Tcm-diethylentriamine pentaacetic acid renal dynamic imaging in renal cercinoma patients before surgery

    International Nuclear Information System (INIS)

    Shao Xiaonan; Wang Yuetao; Wang Xiaosong; Chen Hailong

    2011-01-01

    Objective: To investigate the clinical significance of glomerular filtration rate (GFR) measured by 99 Tc m -diethylenetriamine pentaacetic acid ( 99 Tc m -DTPA) renal dynamic imaging in renal cell carcinoma (RCC) patients before surgery. Methods: There were 99 cases of RCC patients, 89 patients undergoing radical nephrectomy (RN) and 10 patients undergoing nephron-sparing surgery(NSS). 99 Tc m -DTPA renal dynamic imaging was performed for determining GFR before surgery. Make a comparison of GFR between RCC group and control group (normal kidney donors), RN group and NSS group. Make a comparison between GFR and serum creatinine in determining preoperative renal dysfunction of RCC patients. All of the data were analyzed by t-test and χ 2 -text. Results: Compared with control group, total GFR of RCC patients was lower, but there was no significant difference [(76.4±20.4)ml/min vs. (80.6±17.4)ml/min, t=0.650, P>0.05)]. Nineteen cases (19.2%) of RCC patients had preoperative renal dysfunction (total GFR 133μmol/L). There was no significant difference in GFR of neoplastic kidneys between RN group and NSS group [(34.1±11.7)ml/min vs.(37.9±11.9)ml/min, t=0.975, P>0.05]. GFR of contralateral kidneys was lower in NSS group than RN group [(32.7±10.3)ml/min vs. (39.6±10.1)ml/min, t=0.044, P 2 =6.808, P<0.01). Conclusion: GFR can provide the accurate information of both kidneys and single kidney before surgery, and this result possessed an important significance in choice of treatments. (authors)

  2. Accuracy and precision of the CKD-EPI and MDRD predictive equations compared with glomerular filtration rate measured by inulin clearance in a Saudi population.

    Science.gov (United States)

    Al-Wakeel, Jamal Saleh

    2016-01-01

    Predictive equations for estimating glomerular filtration rate (GFR) in different clinical conditions should be validated by comparing with the measurement of GFR using inulin clearance, a highly accurate measure of GFR. Our aim was to validate the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) equations by comparing it to the GFR measured using inulin clearance in chronic kidney disease (CKD) patients. Cross-sectional study performed in adult Saudi patients with CKD. King Saud University Affiliated Hospital, Riyadh, Saudi Arabia in 2014. We compared GFR measured by inulin clearance with the estimated GFR calculated using CKD-EPI and MDRD predictive formulas. Correlation, bias, precision and accuracy between the estimated GFR and inulin clearance. Comparisons were made in 31 participants (23 CKD and 8 transplanted), including 19 males (mean age 42.2 [15] years and weight 68.7 [18] kg). GFR using inulin was 51.54 (33.8) mL/min/1.73 m2 in comparison to inulin clearance, the GFR by the predictive equations was: CKD-EPI creatinine 52.6 (34.4) mL/ min/1.73 m2 (P=.490), CKD-EPI cystatin C 41.39 (30.30) mL/min/1.73 m2 (P=.002), CKD creatinine-cystatin C 45.03 (30.9) mL/min/1.73 m2 (P=.004) and MDRD GFR 48.35 (31.5) mL/min/1.73 m2 (P=.028) (statistical comparisons vs inulin). Bland-Altman plots demonstrated that GFR estimated by the CKD-EPI creatinine was the most accurate compared with inulin clearance, having a mean difference (estimated bias) and limits of agreement of -1.1 (15.6,-17.7). By comparison the mean differences for predictive equations were: CKD-EPI cystatin C 10.2 (43.7,-23.4), CKD creatinine-cystatin C 6.5 (29.3,-16.3) and MDRD 3.2 (18.3,-11.9). except for CKD-EPI creatinine, all of the equations underestimated GFR in comparison with inulin clearance. When compared with inulin clearance, the CKD-EPI creatinine equation is the most accurate, precise and least biased equation for estimation of GFR

  3. Clinical dehydration and glomerular filtration rate in acute paediatric gastroenteritis.

    Science.gov (United States)

    Milani, Gregorio P; Fossali, Emilio F; Perri, Alessandra; Vettori, Arianna; Grillo, Paolo; Agostoni, Carlo

    2013-08-01

    To evaluate changes in glomerular filtration rate in acute gastroenteritis. The correlation between two clinical diagnostic scales and glomerular filtration rate has been investigated in 113 children with acute gastroenteritis in a paediatric emergency setting. A significant reduction of GFR was found in 10% children less than, and 5% children higher than, 2 years of age with acute gastroenteritis. The differences observed as for risk of renal hypoperfusion suggests to consider the age of children as an important determinant to consider the dehydration status in acute gastroenteritis. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  4. Reduced glomerular filtration rate as a predictor of coronary artery ...

    African Journals Online (AJOL)

    Tarek A. Ghonemy

    2016-07-09

    Jul 9, 2016 ... Internal Medicine Department, Nephrology Unit, Zagazig University ... glomerular filtration rate (eGFR) and risk of coronary artery disease ... ing of eGFR may have a pivotal role in early detection and management of CAD in those types of ..... position statement from kidney disease improving global out-.

  5. The Comparative Study of the Measurement of Serum Cystatin C and 99mTc-DTPA for the Measurement of Glomerular Filtration Rate (GFR) in Type 2 Diabetic Nephropathy

    International Nuclear Information System (INIS)

    Kong Linghua; Wu Junyuan; Gao Bin; Wang Xueqin; Gu Kaikai

    2010-01-01

    To explore the clinical value between measurement of serum cystatin C (Cys C) and determination of plasma with 99m Tc-DTPA glomerular filtration rate (GFR) clearance for type 2 diabetes (T2DM) in early detection of renal damage, the serum cystatin C levels in 87 patients with type 2 diabetes were determined by immune turbidimetry Cys C. The patients were also carried out dynamic imaging to measure renal GFR. The result showed that the serum levels of Cys C in patients with Type 2 diabetic was 1.68 ± 0.52 mg / L, the normal group was 0.72±0.26 mg/L; The GFR in patients with T2DM was 93.8 ± 30.2 ml/min/1.73m 2 , the control group was 107.48±15.23 ml/min/1.73m 2 , there was significant difference between patients and controls (P 99m Tc-DTPA renal dynamic imaging. The serum Cys C could reflect the damage in early diabetic patients. The method is simple, accurate and easy to spread. The renal dynamic imaging method of GFR determination is slightly complex and requires specialized equipment. It can reflect the sub-renal function. The combined measurement of serum Cys C and GFR are very important in the early detection of type 2 diabetic patients with early renal function. (authors)

  6. Functional principal component analysis of glomerular filtration rate curves after kidney transplant.

    Science.gov (United States)

    Dong, Jianghu J; Wang, Liangliang; Gill, Jagbir; Cao, Jiguo

    2017-01-01

    This article is motivated by some longitudinal clinical data of kidney transplant recipients, where kidney function progression is recorded as the estimated glomerular filtration rates at multiple time points post kidney transplantation. We propose to use the functional principal component analysis method to explore the major source of variations of glomerular filtration rate curves. We find that the estimated functional principal component scores can be used to cluster glomerular filtration rate curves. Ordering functional principal component scores can detect abnormal glomerular filtration rate curves. Finally, functional principal component analysis can effectively estimate missing glomerular filtration rate values and predict future glomerular filtration rate values.

  7. Estimated Glomerular Filtration Rate; Laboratory Implementation and Current Global Status.

    Science.gov (United States)

    Miller, W Greg; Jones, Graham R D

    2018-01-01

    In 2002, the Kidney Disease Outcomes Quality Initiative guidelines for identifying and treating CKD recommended that clinical laboratories report estimated glomerular filtration rate (eGFR) with every creatinine result to assist clinical practitioners to identify people with early-stage CKD. At that time, the original Modification of Diet in Renal Disease (MDRD) Study equation based on serum creatinine measurements was recommended for calculating eGFR. Because the MDRD Study equation was developed using a nonstandardized creatinine method, a Laboratory Working Group of the National Kidney Disease Education program was formed and implemented standardized calibration traceability for all creatinine methods from global manufacturers by approximately 2010. A modified MDRD Study equation for use with standardized creatinine was developed. The Chronic Kidney Disease Epidemiology Collaboration developed a new equation in 2009 that was more accurate than the MDRD Study equation at values above 60 mL/min/1.73 m 2 . As of 2017, reporting eGFR with creatinine is almost universal in many countries. A reference system for cystatin C became available in 2010, and manufacturers are in the process to standardize cystatin C assays. Equations for eGFR based on standardized cystatin C alone and with creatinine are now available from the Chronic Kidney Disease Epidemiology Collaboration and other groups. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  8. Measurement and characterization of filtration efficiencies for prefilter materials used in aerosol filtration

    International Nuclear Information System (INIS)

    Sciortino, J.

    1991-01-01

    In applications where the filtration of large quantities of mixed (liquid and solid) aerosols is desired, a multistage filtration system is often employed. This system consists of a prefilter, a High Efficiency Particulate Air (HEPA) filter, and any number of specialized filters particular to the filtration application. The prefilter removes liquids and any large particles from the air stream, keeping them from prematurely loading the HEPA filter downstream. The HEPA filter eliminates 99.97% of all particulates in the aerosol. The specialized filters downstream of the HEPA filter can be used to remove organic volatiles or other vapors. While the properties of HEPA filters have been extensively investigated, literature characterizing the prefilter is scarce. The purpose of this report is to characterize the efficiency of the prefilter as a function of particle size, nature of the particle (solid or liquid), and the gas flow rate across the face of the prefilter. 1 ref., 4 figs

  9. [Why? How? What for? We must measure the glomerular filtration].

    Science.gov (United States)

    Treviño-Becerra, Alejandro

    2010-01-01

    The measurement of the glomerular filtration shows the degree of the functional qualities and the proficiency of the renal system. Despite new technologies, at present the best accepted technique for measuring the glomerular filtration in most countries is the clearance of creatinine in 24 hour urine. The clearance of creatinine has the advantage that it is confident, easy to reproduce, without technical limitations and low cost.

  10. Validation of estimated glomerular filtration rate equations for Japanese children.

    Science.gov (United States)

    Gotoh, Yoshimitsu; Uemura, Osamu; Ishikura, Kenji; Sakai, Tomoyuki; Hamasaki, Yuko; Araki, Yoshinori; Hamda, Riku; Honda, Masataka

    2018-01-25

    The gold standard for evaluation of kidney function is renal inulin clearance (Cin). However, the methodology for Cin is complicated and difficult, especially for younger children and/or patients with bladder dysfunction. Therefore, we developed a simple and easier method for obtaining the estimated glomerular filtration rate (eGFR) using equations and values for several biomarkers, i.e., serum creatinine (Cr), serum cystatin C (cystC), serum beta-2 microglobulin (β 2 MG), and creatinine clearance (Ccr). The purpose of the present study was to validate these equations with a new data set. To validate each equation, we used data of 140 patients with CKD with clinical need for Cin, using the measured GFR (mGFR). We compared the results for each eGFR equation with the mGFR using mean error (ME), root mean square error (RMSE), P 30 , and Bland-Altman analysis. The ME of Cr, cystC, β 2 MG, and Ccr based on eGFR was 15.8 ± 13.0, 17.2 ± 16.5, 15.4 ± 14.3, and 10.6 ± 13.0 ml/min/1.73 m 2 , respectively. The RMSE was 29.5, 23.8, 20.9, and 16.7, respectively. The P 30 was 79.4, 71.1, 69.5, and 92.9%, respectively. The Bland-Altman bias analysis showed values of 4.0 ± 18.6, 5.3 ± 16.8, 12.7 ± 17.0, and 2.5 ± 17.2 ml/min/1.73 m 2 , respectively, for these parameters. The bias of each eGFR equation was not large. Therefore, each eGFR equation could be used.

  11. Dynamics of intrarenal pressures and glomerular filtration rate after acetazolamide

    DEFF Research Database (Denmark)

    Leyssac, P P; Karlsen, F M; Skøtt, O

    1991-01-01

    -EDTA and lithium. Proximal tubular pressure (Pprox) increased initially by 1.7 +/- 0.1 mmHg after ACZ, causing a decrease in the hydrostatic pressure difference across the glomerular membrane (delta P). EDC increased, and then RBF, glomerular capillary pressure (Pgc), Pprox, and star vessel pressures (Psv) dropped......The dynamics of intrarenal pressures, early distal tubular fluid conductivity (EDC), and renal flood flow (RBF) were studied in rats given acetazolamide (ACZ), an inhibitor of proximal reabsorption. Glomerular filtration rate (GFR) and end-proximal flow were estimated by clearances of 51Cr...... as a result of afferent vasoconstriction. Pprox decreased less than Pgc, resulting in a further decrease in delta P, which after 25-30 s reached a constant level 3-4 mmHg below control. After a transient increase the pressures declined to a new steady state, in which Pprox was equal to control, Pgc...

  12. Growth of mussels Mytilus edulis at algal (Rhodomonas salina) concentrations below and above saturation level for reduced filtration rate

    DEFF Research Database (Denmark)

    Riisgård, Hans Ulrik; Pleissner, Daniel; Larsen, Poul Scheel

    2013-01-01

    Average filtration and growth rates of groups of juvenile Mytilus edulis (n =2545 of 22-35 mm shell length) were measured at different concentrations of an algal cell monoculture in 9 laboratory experiments of duration 14-30 days, 4 experiments below and 5 above the limit of incipient saturation...... concentration (Csat ≈ 6000-7000 Rhodomonas salina cells ml-1). From a nearly constant filtration rate (F ≈ 30 ml min-1 for a 30 mm shell length) at measured algal concentrations below Csat the steady-state filtration rate decreased approximately as 1/C for increasing algal concentrations (C) above Csat...... is exceeded and then as partial valve closure and reduced filtration and growth rates along with production of pseudofaeces. A survey of naturally occurring phytoplankton biomass in the sea shows that this is generally below Csat except for the short spring bloom periods; hence mussels generally feed...

  13. Rapid decline in glomerular filtration rate during the first weeks following heart transplantation

    DEFF Research Database (Denmark)

    Hornum, M; Andersen, Mads Jønsson; Gustafsson, F

    2011-01-01

    We hypothesized that a decrease in renal function is seen immediately after heart transplantation (HTX) with little recovery over time. Twelve consecutive patients had their glomerular filtration rate (GFR) measured using (51)Cr-ethylenediaminetetraacetic acid (EDTA) measured GFR (mGFR) before tr...... risk factor for the rapid and sustained decrease in renal function supports the need for more studies on renoprotective strategies immediately after HTX....

  14. Effect of estimated glomerular filtration rate on plasma concentrations of B-type natriuretic peptides measured with multiple immunoassays in elderly individuals

    DEFF Research Database (Denmark)

    Schou, M.; Alehagen, U.; Goetze, J.P.

    2009-01-01

    linear regression models. RESULTS: In univariate analyses the effect of a 10% decrease in eGFR on proBNP concentrations was a 15% (95% confidence interval 11% to 18%), 9% (5% to 13%) and 21% (14% to 28%) increase. In multivariate models the effect was a 7% (3% to 11%), 4% (2% to 6%) and 13% (4% to 20....... SETTING: 474 elderly outpatients with suspected heart failure (prevalence 13%) from the primary care. MAIN OUTCOME MEASURES: The effects of eGFR on proBNP, measured with three different immunoassays (Roche Diagnostics, Oslo and Copenhagen), and BNP (Shionogi) concentrations were evaluated by multiple...

  15. Did Creatinine Standardization Give Benefits to the Evaluation of Glomerular Filtration Rate?

    OpenAIRE

    Piéroni, Laurence; Bargnoux, Anne-Sophie; Cristol, Jean-Paul; Cavalier, Etienne; Delanaye, Pierre

    2017-01-01

    During the last decade, a lot of efforts has been made to improve the evaluation of renal functions. Measured Glomerular Filtration Rate (GFR) remains the only valuable test to confirm or confute the status of chronic kidney disease (CKD) and is recommended by Kidney Disease Global Outcomes guidelines when estimation of GFR is not reliable. However, in routine clinical practice, serum creatinine remains the one of the most prescribed biological parameters and is an undeniable factor, alone or...

  16. The effect of temperature and body size on filtration rates of Limnoperna fortunei (Bivalvia, Mytilidae under laboratory conditions

    Directory of Open Access Journals (Sweden)

    Débora Pestana

    2009-02-01

    Full Text Available The golden mussel (Limnoperna fortunei, Mollusca: Bivalvia is an invasive species that has been causing considerable environmental and economic problems in South America. In the present study, filtration rates of L. fortunei were determined in the laboratory under different temperatures (10, 15, 20, 25, 28, and 30 ºC and two types of food (Algamac-2000® and the chlorophycean alga Scenedesmus sp.. There was a statistically significant relationship between time and filtration rates in the experiment using Scenedesmus sp., regardless of temperature. However, this pattern was absent in the experiment using Algamac, suggesting that the relationship between filtration rates and temperature might depend on the size of the filtered particles. In addition, there was no correlation between filtration rates and either shell size or condition index (the relationship between the weight and the length of a mussel. The filtration rate measured in the present study (724.94 ml/h was one of the highest rates recorded among invasive bivalves to date. Given that the colonies of the golden mussel could reach hundreds of thousands of individuals per square meter, such filtration levels could severely impact the freshwater environments in its introduced range.

  17. Ultra-filtration measurement using CT imaging technology

    International Nuclear Information System (INIS)

    Lu Junfeng; Lu Wenqiang

    2009-01-01

    As a functional unit in the hemodialysis process, dialyzer captured quite a few medical research interests since 1980s. In the design of dialyzer or in the ongoing hemodialysis process, to estimate the ultra-filtration amount of a dialyzer, the sideway loss of the running blood flow through hollow fibers or filtration channels should be measured. This further leads to the measurement of the blood flow inside the dialyzer. For this measurement, a non-invasive method is highly desired because of the high-dense bundled hollow fibers or packed channels inside the dialyzer. As non-invasive measurement tools, CT (Computed Tomography) technologies were widely used for tissue, bone, and cancerous clinical analyses etc .... Thus, in this paper, a CT system is adopted to predict the blood flow inside a hollow fiber dialyzer. In view of symmetric property of the hollow fiber dialyzer, the largest cutting plane that parallels to the cylindrical dialyzer was analyzed by the CT system dynamically. And then, a noninvasive image analysis method used to predict the ultra-filtration amount is proposed.

  18. Estimating glomerular filtration rate in a population-based study

    Directory of Open Access Journals (Sweden)

    Anoop Shankar

    2010-07-01

    Full Text Available Anoop Shankar1, Kristine E Lee2, Barbara EK Klein2, Paul Muntner3, Peter C Brazy4, Karen J Cruickshanks2,5, F Javier Nieto5, Lorraine G Danforth2, Carla R Schubert2,5, Michael Y Tsai6, Ronald Klein21Department of Community Medicine, West Virginia University School of Medicine, Morgantown, WV, USA; 2Department of Ophthalmology and Visual Sciences, 4Department of Medicine, 5Department of Population Health Sciences, University of Wisconsin, School of Medicine and Public Health, Madison, WI, USA; 3Department of Community Medicine, Mount Sinai School of Medicine, NY, USA; 6Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, USABackground: Glomerular filtration rate (GFR-estimating equations are used to determine the prevalence of chronic kidney disease (CKD in population-based studies. However, it has been suggested that since the commonly used GFR equations were originally developed from samples of patients with CKD, they underestimate GFR in healthy populations. Few studies have made side-by-side comparisons of the effect of various estimating equations on the prevalence estimates of CKD in a general population sample.Patients and methods: We examined a population-based sample comprising adults from Wisconsin (age, 43–86 years; 56% women. We compared the prevalence of CKD, defined as a GFR of <60 mL/min per 1.73 m2 estimated from serum creatinine, by applying various commonly used equations including the modification of diet in renal disease (MDRD equation, Cockcroft–Gault (CG equation, and the Mayo equation. We compared the performance of these equations against the CKD definition of cystatin C >1.23 mg/L.Results: We found that the prevalence of CKD varied widely among different GFR equations. Although the prevalence of CKD was 17.2% with the MDRD equation and 16.5% with the CG equation, it was only 4.8% with the Mayo equation. Only 24% of those identified to have GFR in the range of 50–59 mL/min per 1

  19. Renal Blood Flow, Glomerular Filtration Rate, and Renal Oxygenation in Early Clinical Septic Shock.

    Science.gov (United States)

    Skytte Larsson, Jenny; Krumbholz, Vitus; Enskog, Anders; Bragadottir, Gudrun; Redfors, Bengt; Ricksten, Sven-Erik

    2018-06-01

    Data on renal hemodynamics, function, and oxygenation in early clinical septic shock are lacking. We therefore measured renal blood flow, glomerular filtration rate, renal oxygen consumption, and oxygenation in patients with early septic shock. Prospective comparative study. General and cardiothoracic ICUs. Patients with norepinephrine-dependent early septic shock (n = 8) were studied within 24 hours after arrival in the ICU and compared with postcardiac surgery patients without acute kidney injury (comparator group, n = 58). None. Data on systemic hemodynamics and renal variables were obtained during two 30-minute periods. Renal blood flow was measured by the infusion clearance of para-aminohippuric acid, corrected for renal extraction of para-aminohippuric acid. Renal filtration fraction was measured by renal extraction of chromium-51 labeled EDTA. Renal oxygenation was estimated from renal oxygen extraction. Renal oxygen delivery (-24%; p = 0.037) and the renal blood flow-to-cardiac index ratio (-21%; p = 0.018) were lower, renal vascular resistance was higher (26%; p = 0.027), whereas renal blood flow tended to be lower (-19%; p = 0.068) in the septic group. Glomerular filtration rate (-32%; p = 0.006) and renal sodium reabsorption (-29%; p = 0.014) were both lower in the septic group. Neither renal filtration fraction nor renal oxygen consumption differed significantly between groups. Renal oxygen extraction was significantly higher in the septic group (28%; p = 0.022). In the septic group, markers of tubular injury were elevated. In early clinical septic shock, renal function was lower, which was accompanied by renal vasoconstriction, a lower renal oxygen delivery, impaired renal oxygenation, and tubular sodium reabsorption at a high oxygen cost compared with controls.

  20. Urological disorders in chronic kidney disease in children cohort: clinical characteristics and estimation of glomerular filtration rate.

    Science.gov (United States)

    Dodson, Jennifer L; Jerry-Fluker, Judith V; Ng, Derek K; Moxey-Mims, Marva; Schwartz, George J; Dharnidharka, Vikas R; Warady, Bradley A; Furth, Susan L

    2011-10-01

    Urological disorders are the most common cause of pediatric chronic kidney disease. We determined the characteristics of children with urological disorders and assessed the agreement between the newly developed bedside glomerular filtration rate estimating formula with measured glomerular filtration rate in 586 patients in the Chronic Kidney Disease in Children study. The Chronic Kidney Disease in Children study is a prospective, observational cohort of children recruited from 48 sites in the United States and Canada. Eligibility requirements include age 1 to 16 years and estimated glomerular filtration rate by original Schwartz formula 30 to 90 ml/min/1.73 m(2). Baseline demographics, clinical variables and glomerular filtration rate were assessed. Bland-Altman analysis was conducted to assess agreement between estimated and measured glomerular filtration rates. Of the 586 participants with at least 1 glomerular filtration rate measurement 348 (59%) had an underlying urological diagnosis (obstructive uropathy in 118, aplastic/hypoplastic/dysplastic kidneys in 104, reflux in 87 and other condition in 39). Among these patients median age was 9 years, duration of chronic kidney disease was 7 years and age at first visit with a urologist was less than 1 year. Of the patients 67% were male, 67% were white and 21% had a low birth weight. Median height was in the 24th percentile. Median glomerular filtration rate as measured by iohexol plasma disappearance was 44.8 ml/min/1.73 m(2). Median glomerular filtration rate as estimated by the Chronic Kidney Disease in Children bedside equation was 44.3 ml/min/1.73 m(2) (bias = -0.5, 95% CI -1.7 to 0.7, p = 0.44). Underlying urological causes of chronic kidney disease were present in 59% of study participants. These children were diagnosed early in life, and many had low birth weight and growth delay. There is good agreement between the newly developed Chronic Kidney Disease in Children estimating equations and measured

  1. Optical measurements of lung microvascular filtration coefficient using polysulfone fibers.

    Science.gov (United States)

    Klaesner, J W; Roselli, R J; Evans, S; Pou, N A; Parker, R E; Tack, G; Parham, M

    1994-01-01

    Lung fluid balance, which is governed by the product of net transvascular pressure difference and lung filtration coefficient, can be altered in pulmonary diseases. A simple measurement of the lung filtration coefficient (Kfc) would be clinically useful and has been examined by several researchers. Current methods of determining Kfc include gravimetric measurement in isolated lungs and lymph node cannulation, neither of which can be extended to human use. Optical measurements of protein concentration changes in venous blood can be combined with pressure measurements to calculate Kfc. Blood, though, contains red corpuscles, which tend to absorb and scatter light, obscuring these optical measurements. In this study, an optical system was developed in which a polysulfone filter cartridge was used to remove red blood cells before the filtrate was passed through a spectrophotometer. Absorbance changes caused by changes in concentration of albumin labeled with Evans Blue were monitored at 620 nm after venous pressure was elevated by about 13 cm H2O. Optical measurements of Kfc averaged 0.401 +/- 0.074 (ml/min cm H2O 100 g DLW) for an isolated canine lung. Optical measurements of Kfc (0.363 +/- 0.120 ml/min cm H2O 100 g DLW) were made for the first time in an intact, closed chest sheep in which pulmonary pressure was altered by inflating a Foley balloon in the left atrium. We conclude that absorbance and scattering artifacts introduced by red blood cells can be eliminated by first filtering the blood through polysulfone fibers. Kfc measurements using the optical method are similar to values obtained by others using gravimetric methods. Finally, we have demonstrated that the technique can be used to estimate Kfc in an intact animal.

  2. Rapid decline in glomerular filtration rate during the first weeks following heart transplantation

    DEFF Research Database (Denmark)

    Hornum, M; Andersen, M; Gustafsson, F

    2011-01-01

    We hypothesized that a decrease in renal function is seen immediately after heart transplantation (HTX) with little recovery over time. Twelve consecutive patients had their glomerular filtration rate (GFR) measured using (51)Cr-ethylenediaminetetraacetic acid (EDTA) measured GFR (mGFR) before...... transplantation and at 1, 2, 3, and 26 weeks after transplantation. The mGFR decreased by 28% and 24% during the first 3 and 26 weeks, respectively, with mean blood cyclosporine concentration as an independent risk factor for the decrease in mGFR. The identification of cyclosporine A (CsA) as the most important...

  3. Relationship between oxygen concentration, respiration and filtration rate in blue mussel Mytilus edulis

    Science.gov (United States)

    Tang, Baojun; Riisgård, Hans Ulrik

    2018-03-01

    The large water-pumping and particle-capturing gills of the filter-feeding blue mussel Mytilus edulis are oversized for respiratory purposes. Consequently, the oxygen uptake rate of the mussel has been suggested to be rather insensitive to decreasing oxygen concentrations in the ambient water, since the diffusion rate of oxygen from water flowing through the mussel determines oxygen uptake. We tested this hypothesis by measuring the oxygen uptake in mussels exposed to various oxygen concentrations. These concentrations were established via N2-bubbling of the water in a respiration chamber with mussels fed algal cells to stimulate fully opening of the valves. It was found that mussels exposed to oxygen concentrations decreasing from 9 to 2 mg O2/L resulted in a slow but significant reduction in the respiration rate, while the filtration rate remained high and constant. Thus, a decrease of oxygen concentration by 78% only resulted in a 25% decrease in respiration rate. However, at oxygen concentrations below 2 mg O2/L M. edulis responded by gradually closing its valves, resulting in a rapid decrease of filtration rate, concurrent with a rapid reduction of respiration rate. These observations indicated that M. edulis is no longer able to maintain its normal aerobic metabolism at oxygen concentration below 2 mg O2/L, and there seems to be an energy-saving mechanism in bivalve molluscs to strongly reduce their activity when exposed to low oxygen conditions.

  4. Effect of treatment with reserpine on the change in filtration rate of Mytilus edulis subjected to dissolved copper

    Energy Technology Data Exchange (ETDEWEB)

    Howell, R.; Grant, A.M.; Maccoy, N.E.J.

    1984-12-01

    Exposure of specimens of Mytilus edulis to dissolved copper leads to a fall in the filtration rate measured in whole animals. The copper concentration leading to a 50% reduction in the filtration rate was found to be 0.094 mg I/sup -1/. This effect was abolished on depletion of the monoamine content of the animal using reserpine. It is suggested that there may be a chemosensory mechanism present in the animals which responds to increased levels of metals in the seawater leading to a reduction in the rate of ciliary beating and mediated via the branchial nerve. 15 references, 2 figures.

  5. Initial formal toxicity evaluation of APC-2, a novel fluorescent tracer agent for real-time measurement of glomerular filtration rate in preparation for a first-in-man clinical trial

    Science.gov (United States)

    Bugaj, Joseph E.; Dorshow, Richard B.

    2014-03-01

    The fluorescent tracer agent 2,5-bis[N-(1-carboxy-2-hydroxy)]carbamoyl-3,6-diaminopyrazine, designated APC-2, has been developed with properties and attributes necessary for use as a direct measure of glomerular filtration rate (GFR). Comparison to known standard exogenous GFR agents in animal models has demonstrated an excellent correlation. A clinical trial to demonstrate this same correlation in humans is in preparation. A battery of formal toxicity tests necessary for regulatory clearance to proceed with a clinical trial has been recently completed on this new fluorescent tracer agent. These include single dose toxicity studies in rats and dogs to determine overall toxicity and toxicokinetics of the compound. Blood compatibility, mutation assay, chromosomal aberration assay, and several other assays were also completed. Toxicity assessments were based on mortality, clinical signs, body weight, food consumption and anatomical pathology. Blood samples were collected to assess pharmacokinetic parameters including half-life, area under the curve, and clearance. Urine samples were collected to assess distribution. Doses of up to 200-300 times the estimated human dose were administered. No test-article related effects were noted on body weight, food consumption, ophthalmic observations and no abnormal pathology was seen in either macroscopic or microscopic evaluations of any organs or tissues. All animals survived to scheduled sacrifice. Transient discoloration of skin and urine was noted at the higher dose levels in both species as expected from a highly fluorescent compound and was not considered pathological. Thus initial toxicology studies of this new fluorescent tracer agent APC-2 have resulted in no demonstrable pathological test article concerns.

  6. Estimated glomerular filtration rate is an early biomarker of cardiac surgery-associated acute kidney injury.

    Science.gov (United States)

    Candela-Toha, Ángel; Pardo, María Carmen; Pérez, Teresa; Muriel, Alfonso; Zamora, Javier

    2018-04-20

    and objective Acute kidney injury (AKI) diagnosis is still based on serum creatinine and diuresis. However, increases in creatinine are typically delayed 48h or longer after injury. Our aim was to determine the utility of routine postoperative renal function blood tests, to predict AKI one or 2days in advance in a cohort of cardiac surgery patients. Using a prospective database, we selected a sample of patients who had undergone major cardiac surgery between January 2002 and December 2013. The ability of the parameters to predict AKI was based on Acute Kidney Injury Network serum creatinine criteria. A cohort of 3,962 cases was divided into 2groups of similar size, one being exploratory and the other a validation sample. The exploratory group was used to show primary objectives and the validation group to confirm results. The ability to predict AKI of several kidney function parameters measured in routine postoperative blood tests, was measured with time-dependent ROC curves. The primary endpoint was time from measurement to AKI diagnosis. AKI developed in 610 (30.8%) and 623 (31.4%) patients in the exploratory and validation samples, respectively. Estimated glomerular filtration rate using the MDRD-4 equation showed the best AKI prediction capacity, with values for the AUC ROC curves between 0.700 and 0.946. We obtained different cut-off values for estimated glomerular filtration rate depending on the degree of AKI severity and on the time elapsed between surgery and parameter measurement. Results were confirmed in the validation sample. Postoperative estimated glomerular filtration rate using the MDRD-4 equation showed good ability to predict AKI following cardiac surgery one or 2days in advance. Copyright © 2018 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  7. Increased kidney size, glomerular filtration rate and renal plasma flow in short-term insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Christiansen, JS; Gammelgaard, J; Frandsen, M

    1981-01-01

    Glomerular filtration rate (GFR), renal plasma flow (RPF) and kidney volume were measured in thirteen male subjects (mean age 30 years) with short-term insulin-dependent diabetes (mean duration of disease 2.4 years) and fourteen normal male subjects (mean age 29 years). GFR and RPF were measured...

  8. Estimated glomerular filtration rate, chronic kidney disease and antiretroviral drug use in HIV-positive patients

    DEFF Research Database (Denmark)

    Mocroft, Amanda; Kirk, Ole; Reiss, Peter

    2010-01-01

    with at least three serum creatinine measurements and corresponding body weight measurements from 2004 onwards. METHODS:: CKD was defined as either confirmed (two measurements >/=3 months apart) estimated glomerular filtration rate (eGFR) of 60 ml/min per 1.73 m or below for persons with baseline eGFR of above...... cumulative exposure to tenofovir [incidence rate ratio (IRR) per year 1.16, 95% CI 1.06-1.25, P ... increased rate of CKD. Consistent results were observed in wide-ranging sensitivity analyses, although of marginal statistical significance for lopinavir/r. No other antiretroviral dugs were associated with increased incidence of CKD. CONCLUSION:: In this nonrandomized large cohort, increasing exposure...

  9. Renin-angiotensin system antagonists, glomerular filtration rate and blood pressure

    Directory of Open Access Journals (Sweden)

    D.D. Ivanov

    2018-02-01

    Full Text Available The article deals with the mModern data on the influence of renin-angiotensin system blockers on the glomerular filtration rate, the level of arterial pressure and the outcome of chronic kidney disease. The strategy of  rennin-angiotensine blockade is offered to be changed depending on the criteria va­lues of glomerular filtration rate: a combination of inhibitors of angiotensin-converting enzyme + angiotensin receptors blo­ckers, monotherapy and drug withdrawal in glomerular filtration rate under 15–30 ml/min/m2. The formula BRIMONEL for treatment of chronic kidney disease is given.

  10. SUSPENSION-FEEDING IN MARINE SPONGES HALICHONDRIA-PANICEA AND HALICLONA-URCEOLUS - EFFECTS OF TEMPERATURE ON FILTRATION-RATE AND ENERGY-COST OF PUMPING

    DEFF Research Database (Denmark)

    Riisgård, H.U.; Thomassen, S.; Jakobsen, H.

    1993-01-01

    Filtration rate (measured as clearance of algal cells) was measured at different temperatures in the sponge Halichondria panicea. An increase in water temperature from 6 to 12-degrees-C caused the mean filtration rate to increase 4.3 +/- 2.3 times. This value was higher than previously found...... for other marine ciliary suspension-feeding animals. Filtration rate at 12-degrees-C was also measured in Haliclona urceolus by means of an indirect clearance method in addition to a direct technique for measuring pumping rate. It was found that the 2 sponge species had near-identical filtration rates......, with maximum rates of approximately 60 ml min-1 (g dry weight)-1 at 12-degrees-C. The normal pump pressure, or operating point O(p), of a standard sponge (based on our own measurements and calculations from literature data for a 0.1 g dry weight Haliclona sp.) was estimated as the sum of main contributions...

  11. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  12. Assessment of glomerular filtration rate and effective renal plasma flow in cystic fibrosis

    International Nuclear Information System (INIS)

    Spino, M.; Chai, R.P.; Isles, A.F.; Balfe, J.W.; Brown, R.G.; Thiessen, J.J.; MacLeod, S.M.

    1985-01-01

    A study was conducted to examine renal function in 10 healthy control subjects and eight patients with cystic fibrosis in stable condition. Sequential bolus injections of /sup 99m/Tc-DTPA and 125 I-OIH were administered to assess glomerular filtration rate and effective renal plasma flow, respectively. Blood was subsequently collected for 3 hours, and urine for 24 hours. Renal clearances of both radioisotope markers were virtually identical in patients and controls. Inasmuch as neither glomerular filtration rate nor effective renal plasma flow was enhanced in patients with cystic fibrosis, increased clearance of drugs in these patients is unlikely to be the result of enhanced glomerular filtration or tubular secretion

  13. Automatic Reporting of Creatinine-Based Estimated Glomerular Filtration Rate in Children: Is this Feasible?

    Directory of Open Access Journals (Sweden)

    Andrew Lunn

    2016-07-01

    Full Text Available Creatinine, although widely used as a biomarker to measure renal function, has long been known as an insensitive marker of renal impairment. Patients with reduced renal function can have a creatinine level within the normal range, with a rapid rise when renal function is significantly reduced. As of 1976, the correlation between height, the reciprocal of creatinine, and measured glomerular filtration rate (GFR in children has been described. It has been used to derive a simple formula for estimated glomerular filtration rate (eGFR that could be used at the bedside as a more sensitive method of identifying children with renal impairment. Formulae based on this association, with modifications over time as creatinine assay methods have changed, are still widely used clinically at the bedside and in research studies to assess the degree of renal impairment in children. Adult practice has moved in many countries to computer-generated results that report eGFR alongside creatinine results using more complex, but potentially more accurate estimates of GFR, which are independent of height. This permits early identification of patients with chronic kidney disease. This review assesses the feasibility of automated reporting of eGFR and the advantages and disadvantages of this in children.

  14. Measuring of filtration efficiency of nonwoven textiles in volume from scattered light by seeding particles

    Directory of Open Access Journals (Sweden)

    Sidlof P.

    2013-04-01

    Full Text Available This paper deals with the method which calculates a filtration efficiency of nonwoven textiles from scattered light intensity by seeding particles. Thefiltration efficiency is commonly measured by particle counters. Samples of liquid or gas are taken during a test in front of and behind a filtration material. The concentration of particles is measured and the filtration efficiency is calculated. The filtration efficiency does not have to be uniform in itswhole surface. The uniformity of filtration is another indicator of a quality of filtration materials. Measurements described in this article were performed on a water filtration setup which enables optical access to the place where the filtration material is mounted. Pictures of illuminated seeding particles are made by a laser sheet and a camera. Visualisation of the filtration process enables measuring of the efficiency of separation versus time and also versus two-dimensional position in case of use of a traverse mechanism. The filtration textiles were tested by 1 μm seeding particles. Mean value of light intensity and number of bright pixels in evaluative areas during image analysis were obtained. On the basis of these data, the filtration efficiency iscalculated. The best image analysis method was chosen.

  15. The significance of some methodological effects on filtration and ingestion rates of the rotifer Brachionus plicatilis

    Science.gov (United States)

    Schlosser, H. J.; Anger, K.

    1982-06-01

    Filtration rate (F) and ingestion rate (I) were measured in the rotifer Brachionus plicatilis feeding on the flagellate Dunaliella spec. and on yeast cells (Saccharomyces cerevisiae). 60-min experiments in rotating bottles served as a standard for testing methodological effects on levels of F and I. A lack of rotation reduced F values by 40 %, and a rise in temperature from 18° to 23.5 °C increased them by 42 %. Ingestion rates increased significantly up to a particle (yeast) concentration of ca. 600-800 cells · μl-1; then they remained constant, whereas filtration rates decreased beyond this threshold. Rotifer density (up to 1000 ind · ml-1) and previous starvation (up to 40 h) did not significantly influence food uptake rates. The duration of the experiment proved to have the most significant effect on F and I values: in 240-min experiments, these values were on the average more than 90 % lower than in 15-min experiments. From this finding it is concluded that ingestion rates obtained from short-term experiments (60 min or less) cannot be used in energy budgets, because they severely overestimate the actual long-term feeding capacity of the rotifers. At the lower end of the particle size spectrum (2 to 3 µm) there are not only food cells, but apparently also contaminating faecal particles. Their number increased with increasing duration of experiments and lead to an underestimation of F and I. Elemental analyses of rotifers and their food suggest that B. plicatilis can ingest up to 0.6 mJ or ca. 14 % of its own body carbon within 15 min. The long term average was estimated as 3.4 mJ · ind-1 · d-1 or ca. 75 % of body carbon · d-1.

  16. A Combined Approach to Measure Micropollutant Behaviour during Riverbank Filtration

    Science.gov (United States)

    van Driezum, Inge; Saracevic, Ernis; Derx, Julia; Kirschner, Alexander; Sommer, Regina; Farnleitner, Andreas; Blaschke, Alfred Paul

    2016-04-01

    Riverbank filtration (RBF) systems are widely used as natural treatment process. The advantages of RBF over surface water abstraction are the elimination of for example suspended solids, biodegradable compounds (like specific micropollutants), bacteria and viruses (Hiscock and Grischek, 2002). However, in contrast to its importance, remarkably less is known on the respective external (e.g. industrial or municipal sewage) and the internal (e.g. wildlife and agricultural influence) sources of contaminants, the environmental availability and fate of the various hazardous substances, and its potential transport during soil and aquifer passage. The goal of this study is to get an insight in the behaviour of various micropollutants and microbial indicators during riverbank filtration. Field measurements were combined with numerical modelling approaches. The study area comprises an alluvial backwater and floodplain area downstream of Vienna. The river is highly dynamic, with discharges ranging from 900 m3/s during low flow to 11000 m3/s during flood events. Samples were taken in several monitoring wells along a transect extending from the river towards a backwater river in the floodplain. Three of the piezometers were situated in the first 20 meters away from the river in order to obtain information about micropollutant behaviour close to the river. A total of 9 different micropollutants were analysed in grab samples taken under different river flow conditions (n=33). Following enrichment using SPE, analysis was performed using high performance liquid chromatography-tandem mass spectrometry. Faecal indicators (E. coli and enterococci) and bacterial spores were enumerated in sample volumes of 1 L each using cultivation based methods (ISO 16649-1, ISO 7899-2:2000 and ISO 6222). The analysis showed that some compounds, e.g. ibuprofen and diclofenac, were only found in the river. These compounds were already degraded in the first ten meters away from the river. Analysis of

  17. Effect of Fusarium isolates and their filtrates on respiratory rate and chemical analysis of squash plants.

    Science.gov (United States)

    El-Shenawy, Z; Mansour, M A; El-Behrawi, S

    1978-01-01

    The highly pathogenic isolate stimulated the emergence of the squash seedlings first, caused, however, the highest death rate of the seedlings finally. Fusarium isolates and their culture filtrates inhibited the respiratory rate of squash plants significantly. However, F. oxysporum isolates inhibited respiration more than F. solani isolates. Seasonal changes of respiration decline show that the respiratory rate decreased with plant growth in the case of infested soil and of plants injected with culture filtrates. However, spraying Fusarium culture filtrates on the foliage gave opposite results when the plants grew older. Fusarium solani isolates decreased nitrogen content of squash stems and leaves, while F. oxysporum isolates gave reverse results. Injecting Fusarium culture filtrate into the plant decreased nitrogen content of both stems and leaves, while spraying the foliage with the filtrates increased nitrogen content more than that of the control. Phosphorus content of the stems of squash plants, sown in infested soil, was less than in the control when the plants were treated with F. solani and higher when they were treated with F. oxysporum isolates. On the other hand, the phosphorus content of squash leaves was higher than in the control. In the case of injected plants, however, the phosphorus content in stems and leaves was equal to that of the control or less, and with sprayed plants it was higher than in the control. Infesting the soil with Fusarium isolates and spraying the foliage with their culture filtrates increased potassium content of squash stems and leaves, while injecting the filtrates into the plants decreased potassium content of both stems and leaves.

  18. [Estimating glomerular filtration rate in 2012: which adding value for the CKD-EPI equation?].

    Science.gov (United States)

    Delanaye, Pierre; Mariat, Christophe; Moranne, Olivier; Cavalier, Etienne; Flamant, Martin

    2012-07-01

    Measuring or estimating glomerular filtration rate (GFR) is still considered as the best way to apprehend global renal function. In 2009, the new Chronic Kidney Disease Epidemiology (CKD-EPI) equation has been proposed as a better estimator of GFR than the Modification of Diet in Renal Disease (MDRD) study equation. This new equation is supposed to underestimate GFR to a lesser degree in higher GFR levels. In this review, we will present and deeply discuss the performances of this equation. Based on articles published between 2009 and 2012, this review will underline advantages, notably the better knowledge of chronic kidney disease prevalence, but also limitations of this new equation, especially in some specific populations. We eventually insist on the fact that all these equations are estimations and nephrologists should remain cautious in their interpretation. Copyright © 2012 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  19. Clinical use of estimated glomerular filtration rate for evaluation of kidney function

    DEFF Research Database (Denmark)

    Broberg, Bo; Lindhardt, Morten; Rossing, Peter

    2013-01-01

    is a significant predictor for cardiovascular disease and may along with classical cardiovascular risk factors add useful information to risk estimation. Several cautions need to be taken into account, e.g. rapid changes in kidney function, dialysis, high age, obesity, underweight and diverging and unanticipated......Estimating glomerular filtration rate by the Modification of Diet in Renal Disease or Chronic Kidney Disease Epidemiology Collaboration formulas gives a reasonable estimate of kidney function for e.g. classification of chronic kidney disease. Additionally the estimated glomerular filtration rate...

  20. Assessment of Glomerular Filtration Rate in Clinical Practice | Amira ...

    African Journals Online (AJOL)

    Inulin clearance is the gold standard against which other markers are compared but it is not practical and inulin is in short supply and difficult to measure. Isotopic methods are also reliable and compare well with inulin clearance; however there are issues of radiation exposure and radionuclide requirements. GFR is often ...

  1. The effects of cimetidine on creatinine excretion, glomerular filtration rate and tubular function in renal transplant recipients

    DEFF Research Database (Denmark)

    Olsen, N V; Ladefoged, S D; Feldt-Rasmussen, B

    1989-01-01

    The renal clearance of endogenous creatinine (CCr), sodium (CNa) and lithium (CLi) was determined before and after a single intravenous bolus of cimetidine in nine renal transplant recipients. The glomerular filtration rate (GFR) was measured with 125I-iothalamate clearance (CTh). The initial CCr...... of 65 ml/min (median) was reduced to a nadir of 46 ml/min (p less than 0.01) during the first 2 h after infusion of cimetidine. GFR remained unchanged, and thus the fractional clearance of creatinine (CCr/CTh) was reduced from 1.43 (median) to 1.03 (p less than 0.01). CNa and the fractional excretion...... of sodium decreased throughout the study (p less than 0.05); CLi was unchanged. In conclusion cimetidine, when measured during 1-h clearance periods, interferes with tubular creatinine secretion in the denervated kidney of transplant recipients without affecting the glomerular filtration rate or proximal...

  2. The effects of cimetidine on creatinine excretion, glomerular filtration rate and tubular function in renal transplant recipients

    DEFF Research Database (Denmark)

    Olsen, N V; Ladefoged, S D; Feldt-Rasmussen, B

    1989-01-01

    The renal clearance of endogenous creatinine (CCr), sodium (CNa) and lithium (CLi) was determined before and after a single intravenous bolus of cimetidine in nine renal transplant recipients. The glomerular filtration rate (GFR) was measured with 125I-iothalamate clearance (CTh). The initial CCr...... tubular flow. This suggests that on-going cimetidine treatment must be taken into account when graft function is evaluated by the CCr alone....

  3. estimated glomerular filtration rate and risk of survival in acute stroke

    African Journals Online (AJOL)

    2014-03-03

    Mar 3, 2014 ... ESTIMATED GLOMERULAR FILTRATION RATE AND RISK OF SURVIVAL IN ACUTE STROKE. E. I. Okaka, MBBS, FWACP, F. A. Imarhiagbe, MBChB, FMCP, F. E. Odiase, MBBS, FMCP, O. C. A. Okoye, MBBS, FWACP,. Department of Medicine, University of Benin Teaching Hospital, Benin City, Nigeria.

  4. Nocturnal polyuria is related to absent circadian rhythm of glomerular filtration rate.

    Science.gov (United States)

    De Guchtenaere, A; Vande Walle, C; Van Sintjan, P; Raes, A; Donckerwolcke, R; Van Laecke, E; Hoebeke, P; Vande Walle, J

    2007-12-01

    Monosymptomatic nocturnal enuresis is frequently associated with nocturnal polyuria and low urinary osmolality during the night. Initial studies found decreased vasopressin levels associated with low urinary osmolality overnight. Together with the documented desmopressin response, this was suggestive of a primary role for vasopressin in the pathogenesis of enuresis in the absence of bladder dysfunction. Recent studies no longer confirm this primary role of vasopressin. Other pathogenetic factors such as disordered renal sodium handling, hypercalciuria, increased prostaglandins and/or osmotic excretion might have a role. So far, little attention has been given to abnormalities in the circadian rhythm of glomerular filtration rate. We evaluated the circadian rhythm of glomerular filtration rate and diuresis in children with desmopressin resistant monosymptomatic nocturnal enuresis and nocturnal polyuria. We evaluated 15 children (9 boys) 9 to 14 years old with monosymptomatic nocturnal enuresis and nocturnal polyuria resistant to desmopressin treatment. The control group consisted of 25 children (12 boys) 9 to 16 years old with monosymptomatic nocturnal enuresis without nocturnal polyuria. Compared to the control population, children with nocturnal polyuria lost their circadian rhythm not only for diuresis and sodium excretion but also for glomerular filtration rate. Patients with monosymptomatic nocturnal enuresis and nocturnal polyuria lack a normal circadian rhythm for diuresis and sodium excretion, and the circadian rhythm of glomerular filtration rate is absent. This absence of circadian rhythm of glomerular filtration rate and/or sodium handling cannot be explained by a primary role of vasopressin, but rather by a disorder in circadian rhythm of renal glomerular and/or tubular functions.

  5. A prospective study of glomerular filtration rate and arterial blood pressure in insulin-dependent diabetics with diabetic nephropathy

    DEFF Research Database (Denmark)

    Parving, H H; Smidt, U M; Friisberg, B

    1981-01-01

    Glomerular filtration rate (GFR, single bolus 51Cr-EDTA technique), serum creatinine, proteinuria and arterial blood pressure have been measured prospectively in 14 young onset insulin-dependent diabetics selected by of persistent proteinuria (greater than 0.5 g/day) secondary to diabetic...... in arterial blood pressure to a hypertensive level is an early feature of diabetic nephropathy in young insulin-dependent diabetics....... and 112/mumol/l (NS), proteinuria increased from 1.8 to 3.3 g/day (p less than 0.001) and arterial blood pressure rose from 132/88 to 153/101 mmHg (p less than 0.001). Glomerular filtration rate decreased linearly with time (slope = -0.75, r = 0.99, p less than 0.001) by a mean of 0.75 ml/min/month (range...

  6. Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Delp, William W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Black, Douglas R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-12-01

    This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250m downwind of the I-80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir-fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year-round operation in California. Exhaust ventilation without enhanced filtration produced indoor PM2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection whereas supply MERV16 filtration reduced PM2.55 by 97-98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor-generated particles. Systems with MERV13-16 filters in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM2.5 by 93-98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM2.5. Indoor ozone was 3-4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM2.5 by 25-75% when operated over the hour following cooking. The energy for year-round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.

  7. Creatinine Clearance and Estimated Glomerular Filtration Rate – When are they Interchangeable

    OpenAIRE

    Šimetić, Lucija; Zibar, Lada; Drmić, Sandra; Begić, Ivana; Šerić, Vatroslav

    2015-01-01

    Study goal was to examine which of glomerular rate equations is most suitable for prediction of creatinine clearance. Using a retrospective review of data from 500 hospital patients we calculated glomerular filtration rate according to Cockcroft-Gault equation (C-G), Modification of Diet in Renal Disease Study equation (MDRD) and Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI). We determined if results of these equations were compatible with creatinine clearance, and does...

  8. Filtration influence in a constant potential X-ray machine peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.R.; Vivolo, V.; Xavier, M.; Potiens, M.P.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Navarro, M.V.T., E-mail: dossantos.lucasrodrigues@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador (Brazil)

    2017-09-01

    This work shows the peak voltage measurements for several beam filtrations used in diagnostic radiology, using two types of non-invasive detectors; a voltage meter and a high-resolution spectrometer. The technique chosen for the voltage peak measurements with the spectrometer was the endpoint. The results were compared to the measured ones and showed good similarity to the nominal values. However the voltage meter detector used in this work presented errors for heavier filtrations. (author)

  9. Escaping the correction for body surface area when calculating glomerular filtration rate in children

    International Nuclear Information System (INIS)

    Piepsz, Amy; Tondeur, Marianne; Ham, Hamphrey

    2008-01-01

    51 Cr ethylene diamine tetraacetic acid ( 51 Cr EDTA) clearance is nowadays considered as an accurate and reproducible method for measuring glomerular filtration rate (GFR) in children. Normal values in function of age, corrected for body surface area, have been recently updated. However, much criticism has been expressed about the validity of body surface area correction. The aim of the present paper was to present the normal GFR values, not corrected for body surface area, with the associated percentile curves. For that purpose, the same patients as in the previous paper were selected, namely those with no recent urinary tract infection, having a normal left to right 99m Tc MAG3 uptake ratio and a normal kidney morphology on the early parenchymal images. A single blood sample method was used for 51 Cr EDTA clearance measurement. Clearance values, not corrected for body surface area, increased progressively up to the adolescence. The percentile curves were determined and allow, for a single patient, to estimate accurately the level of non-corrected clearance and the evolution with time, whatever the age. (orig.)

  10. Escaping the correction for body surface area when calculating glomerular filtration rate in children

    Energy Technology Data Exchange (ETDEWEB)

    Piepsz, Amy; Tondeur, Marianne [CHU St. Pierre, Department of Radioisotopes, Brussels (Belgium); Ham, Hamphrey [University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium)

    2008-09-15

    {sup 51}Cr ethylene diamine tetraacetic acid ({sup 51}Cr EDTA) clearance is nowadays considered as an accurate and reproducible method for measuring glomerular filtration rate (GFR) in children. Normal values in function of age, corrected for body surface area, have been recently updated. However, much criticism has been expressed about the validity of body surface area correction. The aim of the present paper was to present the normal GFR values, not corrected for body surface area, with the associated percentile curves. For that purpose, the same patients as in the previous paper were selected, namely those with no recent urinary tract infection, having a normal left to right {sup 99m}Tc MAG3 uptake ratio and a normal kidney morphology on the early parenchymal images. A single blood sample method was used for {sup 51}Cr EDTA clearance measurement. Clearance values, not corrected for body surface area, increased progressively up to the adolescence. The percentile curves were determined and allow, for a single patient, to estimate accurately the level of non-corrected clearance and the evolution with time, whatever the age. (orig.)

  11. [Consensus document: recommendations for the use of equations to estimate glomerular filtration rate in children].

    Science.gov (United States)

    Montañés Bermúdez, R; Gràcia Garcia, S; Fraga Rodríguez, G M; Escribano Subias, J; Diez de Los Ríos Carrasco, M J; Alonso Melgar, A; García Nieto, V

    2014-05-01

    The appearance of the K/DOQI guidelines in 2002 on the definition, evaluation and staging of chronic kidney disease (CKD) have led to a major change in how to assess renal function in adults and children. These guidelines, recently updated, recommended that the study of renal function is based, not only on measuring the serum creatinine concentration, but this must be accompanied by the estimation of glomerular filtration rate (GFR) obtained by an equation. However, the implementation of this recommendation in the clinical laboratory reports in the paediatric population has been negligible. Numerous studies have appeared in recent years on the importance of screening and monitoring of patients with CKD, the emergence of new equations for estimating GFR, and advances in clinical laboratories regarding the methods for measuring plasma creatinine and cystatin C, determined by the collaboration between the departments of paediatrics and clinical laboratories to establish recommendations based on the best scientific evidence on the use of equations to estimate GFR in this population. The purpose of this document is to provide recommendations on the evaluation of renal function and the use of equations to estimate GFR in children from birth to 18 years of age. The recipients of these recommendations are paediatricians, nephrologists, clinical biochemistry, clinical analysts, and all health professionals involved in the study and evaluation of renal function in this group of patients. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  12. Effect of lemongrass tea consumption on estimated glomerular filtration rate and creatinine clearance rate.

    Science.gov (United States)

    Ekpenyong, Christopher E; Daniel, Nyebuk E; Antai, Atim B

    2015-01-01

    The existing research findings regarding the effects of lemongrass (Cymbopogon citratus) tea on renal function indices are conflicting and inconclusive. In the present study, we investigated the effects of infusions prepared from C citratus leaves on creatinine clearance rate (CCr) and estimated glomerular filtration rate (eGFR) in humans. One hundred five subjects (55 men and 50 women) aged 18 to 35 years were randomly assigned to groups set to orally receive infusions prepared from 2, 4, or 8 g of C citratus leaf powder once daily, for 30 days. Serum and urinary levels of urea, creatinine, pH, specific gravity, uric acid, electrolytes, diuretic indices, and eGFR were assessed at days 0, 10, and 30 after the initiation of treatment. Results obtained on days10 and 30 were compared with baseline values. CCr and eGFR decreased significantly at day 30 in both male and female subjects in all the groups and in females treated with infusion prepared from 8 g of C citratus leaf powder for 10 days. At day 10, CCr and eGFR were unchanged in those treated with infusions prepared from 2 or 4 g of the leaf powder, whereas diuretic indices (urine volume, urination frequency, diuretic action, and saliuretic indices) increased above the baseline levels. Serum and urinary creatinine levels significantly increased (P < .05) in both male and female subjects in all the groups. Serum urea significantly increased in the groups treated with infusions prepared from 4 or 8 g of the leaf powder (P < .05) for 30 days. Serum electrolytes remained unchanged, but their urinary levels increased. We observed dose- and time-dependent adverse effects of C citratus on CCr and eGFR. At a high dose or with prolonged treatment with a low dose, eGFR decrease may be followed by a decline in the other renal function indices. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  13. Enhancement of glomerular filtration rate and renal plasma flow by oral glucose load in well controlled insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Sandahl Christiansen, J; Christensen, C K; Hermansen, K

    1986-01-01

    Glomerular filtration rate (GFR) and renal plasma flow (RPF) were measured in 27 patients with uncomplicated insulin-dependent diabetes (IDDM) before and after an oral glucose load of 1.1 g glucose/kg body wt. In the 18 patients showing near-normoglycaemia (blood glucose less than or equal to 8....... No changes in blood pressure or urinary albumin excretion rates took place in either group. The reduction in plasma protein and in plasma growth hormone concentration were similar in the two groups. No change was seen in plasma arginine vasopressin concentration. There was no difference in the qualitative...

  14. Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA

    DEFF Research Database (Denmark)

    Hansen, H P; Rossing, P; Mathiesen, E R

    1998-01-01

    Plasma clearance of 51Cr-EDTA is widely used to assess the glomerular filtration rate (GFR) in diabetic nephropathy. Originally, the ratio between the intravenously injected amount of tracer and the total area under the plasma concentration curve was used for the calculation of total 51Cr...... and rate of decline in GFR based upon these three methods. Bland & Altman plots were used to illustrate the range of agreement. We investigated 76 insulin-dependent diabetic (IDDM) patients with microalbuminuria or diabetic nephropathy. GFR was measured after a single intravenous injection of 3.7 MBq 51Cr...

  15. MDRD or CKD-EPI for glomerular filtration rate estimation in living kidney donors

    Directory of Open Access Journals (Sweden)

    Carla Burballa

    2018-03-01

    Full Text Available Introduction: The evaluation of the measured Glomerular Filtration Rate (mGFR or estimated Glomerular Filtration Rate (eGFR is key in the proper assessment of the renal function of potential kidney donors. We aim to study the correlation between glomerular filtration rate estimation equations and the measured methods for determining renal function. Material and methods: We analyzed the relationship between baseline GFR values measured by Tc-99m-DTPA (diethylene-triamine-pentaacetate and those estimated by the four-variable Modification of Diet in Renal Disease (MDRD4 and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations in a series of living donors at our institution. Results: We included 64 donors (70.6% females; mean age 48.3 ± 11 years. Baseline creatinine was 0.8 ± 0.1 mg/dl and it was 1.1 ± 0.2 mg/dl one year after donation. The equations underestimated GFR when measured by Tc99m-DTPA (MDRD4 – 9.4 ± 25 ml/min, P < .05, and CKD-EPI – 4.4 ± 21 ml/min. The correlation between estimation equations and the measured method was superior for CKD-EPI (r = .41; P < .004 than for MDRD4 (r = .27; P < .05. eGFR decreased to 59.6 ± 11 (MDRD4 and 66.2 ± 14 ml/min (CKD-EPI one year after donation. This means a mean eGFR reduction of 28.2 ± 16.7 ml/min (MDRD4 and 27.31 ± 14.4 ml/min (CKD-EPI at one year. Conclusions: In our experience, CKD-EPI is the equation that better correlates with mGFR-Tc99m-DTPA when assessing renal function for donor screening purposes. Resumen: Introducción: El estudio del filtrado glomerular medido (FGm o del estimado (FGe es el eje de la evaluación adecuada de la función renal en la valoración de un potencial donante vivo renal. Nos planteamos estudiar la correlación entre las fórmulas de estimación del FG y los métodos de medición para

  16. Validation of predictive equations for glomerular filtration rate in the Saudi population

    Directory of Open Access Journals (Sweden)

    Al Wakeel Jamal

    2009-01-01

    Full Text Available Predictive equations provide a rapid method of assessing glomerular filtration rate (GFR. To compare the various predictive equations for the measurement of this parameter in the Saudi population, we measured GFR by the Modification of Diet in Renal Disease (MDRD and Cockcroft-Gault formulas, cystatin C, reciprocal of cystatin C, creatinine clearance, reciprocal of creatinine, and inulin clearance in 32 Saudi subjects with different stages of renal disease. We com-pared GFR measured by inulin clearance and the estimated GFR by the equations. The study included 19 males (59.4% and 13 (40.6% females with a mean age of 42.3 ± 15.2 years and weight of 68.6 ± 17.7 kg. The mean serum creatinine was 199 ± 161 μmol/L. The GFR measured by inulin clearance was 50.9 ± 33.5 mL/min, and the estimated by Cockcroft-Gault and by MDRD equations was 56.3 ± 33.3 and 52.8 ± 32.0 mL/min, respectively. The GFR estimated by MDRD revealed the strongest correlation with the measured inulin clearance (r= 0.976, P= 0.0000 followed by the GFR estimated by Cockcroft-Gault, serum cystatin C, and serum creatinine (r= 0.953, P= 0.0000 (r= 0.787, P= 0.0001 (r= -0.678, P= 0.001, respectively. The reciprocal of cystatin C and serum creatinine revealed a correlation coefficient of 0.826 and 0.93, respectively. Cockroft-Gault for-mula overestimated the GFR by 5.40 ± 10.3 mL/min in comparison to the MDRD formula, which exhibited the best correlation with inulin clearance in different genders, age groups, body mass index, renal transplant recipients, chronic kidney disease stages when compared to other GFR predictive equations.

  17. Effects of a K+ channel blocker on glomerular filtration rate and electrolyte excretion in conscious rats.

    Science.gov (United States)

    Ludens, J H; Clark, M A; Lawson, J A

    1995-06-01

    Effects of a K+ channel blocker on glomerular filtration rate and electrolyte excretion in conscious rats were observed. Effects of K+ channel modulation on glomerular filtration rate and electrolyte excretion were studied using the adenosine-triphosphate- (ATP)-sensitive K+ channel blocker 4-morpholinecarboximidine-N-1-adamantyl-N'-cyclohexylhydr ochloride (U-37883A) in conscious rats previously equipped with catheters for clearance studies. In saline-loaded rats, i.v. doses of U-37883A of 1.7, 5.0 and 15 mg/kg increased absolute and fractional Na+ excretion dose-dependently without changing K+ excretion. The glomerular filtration rate remained constant during diuresis. In water-loaded (hypotonic dextrose) rats, free-water clearance studies revealed that the ATP-sensitive K+ channel blocker significantly decreased an index of solute reabsorption (free-water clearance adjusted for chloride clearance) in the diluting segment during peak natriuretic activity. In addition, U-37883A significantly decreased the osmolality of renal papillary interstitial fluid, indicative of an effect in the medullary portion of the diluting segment. Together, these findings suggest that ATP-sensitive K+ channels, possibly those located at the apical boarder, play a pivotal role in Na+ reabsorption in the thick ascending limb of the loop of Henle.

  18. Glomerular Filtration Rate in Patients with Multiple Sclerosis Undergoing Stem Cell Transplantation and Treated With Cyclophosphamide.

    Science.gov (United States)

    Ruiz-Argüelles, Alejandro; Gastélum-Cano, Jose M; Méndez-Huerta, Mariana A; Rodríguez-Gallegos, Alma B; Ruiz-Argüelles, Guillermo J

    2018-06-15

    Glomerular filtration rate (GFR) is partially impaired in patients with multiple sclerosis (MS). When given chemotherapy before receiving hematopoietic stem-cell transplantation, GFR might be further deteriorated. To measure the effect of cyclophosphamide on GFR in patients with MS who undergo chemotherapy. We estimated GFR based on creatinine and cystatin C plasma concentrations in patients undergoing autologous hematopoietic stem-cell transplantation to treat their MS. Baseline GFR values were lower in the 28 patients with MS than in the 20 healthy individuals. Also, according to the Chronic Kidney Disease-Epidemiology Collaborative Group (CKD-EPI) 2012 Creat-CysC equation criteria, 4 of 28 patients were classified as having chronic kidney disease (CKD) before receiving the chemotherapy drugs. After receiving 4 × 50 mg per kg body weight cyclophosphamide, abnormal GFR results were recorded in 12 of 28 patients. Renal function must be monitored in patients with MS undergoing autologous stem-cell transplantation. Also, chemotherapy should be constrained as much as possible to prevent further deterioration of renal function.

  19. Proenkephalin, Neutrophil Gelatinase-Associated Lipocalin, and Estimated Glomerular Filtration Rates in Patients With Sepsis.

    Science.gov (United States)

    Kim, Hanah; Hur, Mina; Lee, Seungho; Marino, Rossella; Magrini, Laura; Cardelli, Patrizia; Struck, Joachim; Bergmann, Andreas; Hartmann, Oliver; Di Somma, Salvatore

    2017-09-01

    Proenkephalin (PENK) has been suggested as a novel biomarker for kidney function. We investigated the diagnostic and prognostic utility of plasma PENK in comparison with neutrophil gelatinase-associated lipocalin (NGAL) and estimated glomerular filtration rates (eGFR) in septic patients. A total of 167 septic patients were enrolled: 99 with sepsis, 37 with septic shock, and 31 with suspected sepsis. PENK and NGAL concentrations were measured and GFR was estimated by using the isotope dilution mass spectrometry traceable-Modification of Diet in Renal Disease (MDRD) Study and three Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations: CKD-EPI(Cr), CDK-EPI(CysC), and CKD-EPI(Cr-CysC). The PENK, NGAL, and eGFR results were compared according to sepsis severity, presence or absence of acute kidney injury (AKI), and clinical outcomes. The PENK, NGAL, and eGFR results were significantly associated with sepsis severity and differed significantly between patients with and without AKI only in the sepsis group (all Psepsis. © The Korean Society for Laboratory Medicine

  20. Short-term inhibition of prostaglandin synthesis has no effect on the elevated glomerular filtration rate of early insulin-dependent diabetes

    DEFF Research Database (Denmark)

    Christiansen, J S; Feldt-Rasmussen, B; Parving, H H

    1985-01-01

    Glomerular filtration rate and renal plasma flow (constant infusion technique using 125I-iothalamate and 131I-hippuran) were measured twice within a 1-week interval in nine young males with insulin-dependent diabetes of short duration (2-5 years). The study was performed in a randomized double...... +/- 43 versus 560 +/- 52 ml/min X 1.73 m2), when measured during placebo or indomethacin treatment, respectively. It is concluded that the steady-state enhancement of glomerular filtration rate and renal plasma flow found in early insulin-dependent diabetes is not due to an excessive activity...

  1. Rates of Filtration and Ingestion of a Microalga by Philodina roseola (Rotifera: Bdelloidea

    Directory of Open Access Journals (Sweden)

    Raquel Aparecida Moreira

    2016-05-01

    Full Text Available Rotifers play an important role in biogeochemical cycles and organic productivity of freshwater ecosystems due to their high metabolic rates. Information on filter feeding, their main process of energy acquisition, are relevant and still scarce for tropical regions. The rotifers of the class Bdelloidea feed by filtration or scraping consuming small food items, such as bacteria, algae, yeasts or particulate organic matter. We know little of their role in the trophic dynamics in the habitats they occupy and so the aim of this study was to quantify laboratory filtration and ingestion rates of the rotifer Philodina roseola, fed with Raphidocelis subcapitata. The experiment consisted of 10 adult exposure treatment at five concentrations approximately in the range between 104 and 107 cells mL-1, at the temperature of 25 ± 1 °C. The experiments lasted one hour and initial and final concentrations of the algal suspensions were determined by counting the number of cells in a Neubauer chamber. There were no significant differences between the initial and final concentrations of cells in the control group indicating that algal growth did not occur. Philodina roseola filtration rates varied between 0.09 and 0.25 mL ind-1 h-1. Given that filtration is the main process of energy acquisition by Philodina roseola, as well as for most other rotifers, and that it comprises important issues related to trophic dynamics of aquatic ecosystems, additional experimental information is especially important and need to be extended to other types of food and combinations of experimental conditions.

  2. Estimated glomerular filtration rate in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Paula Caitano Fontela

    2014-12-01

    Full Text Available Objective: to estimate the glomerular filtration using the Cockcroft-Gault (CG, Modification of Diet in Renal Disease (MDRD, and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations, and serum creatinine in the screening of reduced renal function in patients with type two diabetes (T2DM enrolled in the Family Health Strategy (ESF, Brazilian federal health-care program. Methods: a cross-sectional descriptive and analytical study was conducted. The protocol consisted of sociodemographics, physical examination and biochemical tests. Renal function was analyzed through serum creatinine and glomerular filtration rate (GFR estimated according to the CG, MDRD and CKD-EPI equations, available on the websites of the Brazilian Nephrology Society (SBN and the (NKF. Results: 146 patients aged 60.9±8.9 years were evaluated; 64.4% were women. The prevalence of serum creatinine >1.2 mg/dL was 18.5% and GFR <60 mL/min/1.73m2 totaled 25.3, 36.3 and 34.2% when evaluated by the equations CG, MDRD and CKD-EPI, respectively. Diabetic patients with reduced renal function were older, had long-term T2DM diagnosis, higher systolic blood pressure and higher levels of fasting glucose, compared to diabetics with normal renal function. Creatinine showed strong negative correlation with the glomerular filtration rate estimated using CG, MDRD and CKD-EPI (-0.64, -0.87, -0.89 equations, respectively. Conclusion: the prevalence of individuals with reduced renal function based on serum creatinine was lower, reinforcing the need to follow the recommendations of the SBN and the National Kidney Disease Education Program (NKDEP in estimating the value of the glomerular filtration rate as a complement to the results of serum creatinine to better assess the renal function of patients.

  3. Estimating Travel Time in Bank Filtration Systems from a Numerical Model Based on DTS Measurements.

    Science.gov (United States)

    des Tombe, Bas F; Bakker, Mark; Schaars, Frans; van der Made, Kees-Jan

    2018-03-01

    An approach is presented to determine the seasonal variations in travel time in a bank filtration system using a passive heat tracer test. The temperature in the aquifer varies seasonally because of temperature variations of the infiltrating surface water and at the soil surface. Temperature was measured with distributed temperature sensing along fiber optic cables that were inserted vertically into the aquifer with direct push equipment. The approach was applied to a bank filtration system consisting of a sequence of alternating, elongated recharge basins and rows of recovery wells. A SEAWAT model was developed to simulate coupled flow and heat transport. The model of a two-dimensional vertical cross section is able to simulate the temperature of the water at the well and the measured vertical temperature profiles reasonably well. MODPATH was used to compute flowpaths and the travel time distribution. At the study site, temporal variation of the pumping discharge was the dominant factor influencing the travel time distribution. For an equivalent system with a constant pumping rate, variations in the travel time distribution are caused by variations in the temperature-dependent viscosity. As a result, travel times increase in the winter, when a larger fraction of the water travels through the warmer, lower part of the aquifer, and decrease in the summer, when the upper part of the aquifer is warmer. © 2017 The Authors. Groundwater published by Wiley Periodicals, Inc. on behalf of National Ground Water Association.

  4. Creatinine Clearance Is Not Equal to Glomerular Filtration Rate and Cockcroft-Gault Equation Is Not Equal to CKD-EPI Collaboration Equation.

    Science.gov (United States)

    Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto

    2016-12-01

    Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    International Nuclear Information System (INIS)

    Kamper, A.L.; Thomsen, H.S.; Nielsen, S.L.; Strandgaard, S.; Herlev Hospital

    1990-01-01

    Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51 Cr-EDTA plasma clearance fell by 14% (P 99m Tc-DMSA increased by 10% (P<0.01). It is concluded that DMSA in chronic renal failure is mainly taken up by the tubular cells from the peritubular capillaries since the uptake was unaffected by the acute decrease in GFR. (orig.)

  6. Tubular markers do not predict the decline in glomerular filtration rate in type 1 diabetic patients with overt nephropathy

    DEFF Research Database (Denmark)

    Nielsen, Stine E; Andersen, Steen; Zdunek, Dietmar

    2011-01-01

    of neutrophil gelatinase-associated lipocalin (NGAL), liver-fatty acid-binding protein (LFABP), and kidney injury molecule-1 (KIM-1) in a 3-year intervention study of 63 type 1 diabetic patients with kidney disease. The baseline mean glomerular filtration rate (GFR) was 87 ml/min per 1.73 m(2) and urinary......Recent studies have shown that both glomerular and tubulointerstitial damage are important factors in the pathophysiology and progression of diabetic nephropathy. To examine whether markers of tubular damage are useful in monitoring the progression of disease, we measured urinary levels...

  7. Renal uptake of dimercaptosuccinic acid and glomerular filtration rate in chronic nephropathy at angiotensin converting enzyme inhibition

    DEFF Research Database (Denmark)

    Kamper, A L; Thomsen, H S; Nielsen, S L

    1990-01-01

    function. Scintigrams of the kidneys showed an unaltered distribution of DMSA during treatment. GFR estimated by 51Cr-EDTA plasma clearance fell by 14% (P less than 0.01), but renal uptake of 99mTc-DMSA increased by 10% (P less than 0.01). It is concluded that DMSA in chronic renal failure is mainly taken......Glomerular filtration rate (GFR) and renal uptake of dimercaptosuccinic acid (DMSA) were measured in 31 patients with progressive chronic nephropathy before and immediately after the start of treatment with angiotensin converting enzyme (ACE) inhibitor in order to control adverse effects on kidney...

  8. Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

    Science.gov (United States)

    Fukuda, Makoto; Yoshimura, Kengo; Namekawa, Koki; Sakai, Kiyotaka

    2017-06-01

    The objective of the present study is to evaluate the effect of filtration coefficient and internal filtration on dialysis fluid flow and mass transfer coefficient in dialyzers using dimensionless mass transfer correlation equations. Aqueous solution of vitamin B 12 clearances were obtained for REXEED-15L as a low flux dialyzer, and APS-15EA and APS-15UA as high flux dialyzers. All the other design specifications were identical for these dialyzers except for filtration coefficient. The overall mass transfer coefficient was calculated, moreover, the exponents of Reynolds number (Re) and film mass transfer coefficient of the dialysis-side fluid (k D ) for each flow rate were derived from the Wilson plot and dimensionless correlation equation. The exponents of Re were 0.4 for the low flux dialyzer whereas 0.5 for the high flux dialyzers. Dialysis fluid of the low flux dialyzer was close to laminar flow because of its low filtration coefficient. On the other hand, dialysis fluid of the high flux dialyzers was assumed to be orthogonal flow. Higher filtration coefficient was associated with higher k D influenced by mass transfer rate through diffusion and internal filtration. Higher filtration coefficient of dialyzers and internal filtration affect orthogonal flow of dialysis fluid.

  9. Metabolic and Hormonal Determinants of Glomerular Filtration Rate and Renal Hemodynamics in Severely Obese Individuals

    Directory of Open Access Journals (Sweden)

    Edoardo Vitolo

    2016-10-01

    Full Text Available Objective: Renal function is often compromised in severe obesity. A true measurement of glomerular filtration rate (GFR is unusual, and how estimation formulae (EstForm perform in such individuals is unclear. We characterized renal function and hemodynamics in severely obese individuals, assessing the reliability of EstForm. Methods: We measured GFR (mGFR by iohexol plasma clearance, renal plasma flow (RPF by 123I-ortho-iodo-hippurate, basal and stimulated vascular renal indices, endothelium-dependent and -independent vasodilation using flow-mediated dilation (FMD as well as metabolic and hormonal profile in morbid, otherwise healthy, obese subjects. Results: Compared with mGFR, the better performing EstForm was CKD-EPI (5.3 ml/min/1.73 m2 bias by Bland-Altman analysis. mGFR was directly related with RPF, total and incremental glucose AUC, and inversely with PTH and h8 cortisol. Patients with mGFR below the median shown significantly higher PTH and lower vitamin D3. Basal or dynamic renal resistive index, FMD, pulse wave velocity were not related with mGFR. In an adjusted regression model, renal diameter and plasma flow remained related with mGFR (R2 = 0.67, accounting for 15% and 21% of mGFR variance, respectively. Conclusions: CKD-EPI formula should be preferred in morbid obesity; glucose increments during oral glucose tolerance test correlate with hyperfiltration; RPF and diameter are independent determinants of mGFR; slightly high PTH values, frequent in obesity, might influence mGFR.

  10. Glomerular filtration rate estimated from the uptake phase of 99mTc-DTPA renography in chronic renal failure

    DEFF Research Database (Denmark)

    Petersen, L J; Petersen, J R; Talleruphuus, U

    1999-01-01

    The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea.......The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea....

  11. Serum C-reactive protein and thioredoxin levels in subjects with mildly reduced glomerular filtration rate

    Directory of Open Access Journals (Sweden)

    Ishimura Eiji

    2010-04-01

    Full Text Available Abstract Background Chronic kidney disease (CKD is a newly recognized high-risk condition for cardiovascular disease (CVD, and previous studies reported the changes in inflammation and oxidative stress in advanced stages of CKD. We compared the levels of serum biomarkers for inflammation and oxidative stress between subjects with normal and mildly reduced glomerular filtration rate (GFR. Methods The subjects were 182 participants of a health check-up program including those with normal (≥ 90 mL/min/1.73 m2, N = 79 and mildly reduced eGFR (60-89 mL/min/1.73 m2, N = 103 which was calculated based on serum creatinine, age and sex. We excluded those with reduced eGFR 2. No one had proteinuria. We measured serum levels of C-reactive protein (CRP and thioredoxin (TRX as the markers of inflammation and oxidative stress, respectively. Results As compared with subjects with normal eGFR, those with mildly reduced eGFR had increased levels of both CRP and TRX. Also, eGFR was inversely correlated with these biomarkers. The associations of eGFR with these biomarkers remained significant after adjustment for age and sex. When adjustment was done for eight possible confounders, CRP showed significant association with systolic blood pressure, high density lipoprotein cholesterol (HDL-C and non-HDL-C, whereas TRX was associated with sex significantly, and with eGFR and systolic blood pressure at borderline significance. Conclusions We showed the increased levels of CRP and TRX in subjects with mildly reduced eGFR. The eGFR-CRP link and the eGFR-TRX link appeared to be mediated, at least partly, by the alterations in blood pressure and plasma lipids in these subjects.

  12. The relationship of serum and urinary laminin and glomerular filtration rate in diabetes mellitus

    International Nuclear Information System (INIS)

    Li Jianlin

    2002-01-01

    Objective: To observe the relationship of serum and urinary laminin and glomerular filtration rate (GFR) in diabetes mellitus. Methods: The level of serum and urinary laminin was measured by radioimmunoassay, GFR acquired by 99m Tc diethylenetriamine pentaacetic acid ( 99m Tc-DTPA), renal dynamic imaging in 75 diabetes mellitus and 42 normal subjects. Results: (1) The level of serum LN (136.30 ± 11.20 ng/ml) and urinary LN (31.76 ± 5.77 ng/ml) in diabetic nephropathy was significantly higher than that in diabetes without nephrosis group (P<0.05) and control group (P<0.01), the level of serum LN (126.54 ± 6.98 ng/ml) and urinary LN (26.27 ± 3.81 ng/ml) in diabetes without nephrosis group was significantly higher than that in control group (P<0.05); the GFR of diabetic nephropathy (78.84 ± 10.79 ng/ml) was significantly lower than that in diabetes without nephrosis group (P<0.05) and control group (P<0.01); the level of serum (131.49 ± 10.74 ng/ml) and urinary LN (29.05 ± 5.60 ng/ml) in diabetes mellitus was significantly higher than that in control group (P<0.05), but GFR was significantly lower than that in control group (P<0.05). (2) The value of GFR in diabetes mellitus lasted less than 1 year was higher than that of control group (P<0.05), but inverse in diabetes mellitus more than 10 years (P<0.05). (3) The level of serum and urinary LN had significantly negative correlation with GFR (P<0.01). Conclusion: LN may accelerates the alteration of GFR and causes microangiopathy of diabetic nephropathy. It may be an important indicator in the diagnosis of the early diabetic nephropathy

  13. Albuminuria and Glomerular Filtration Rate in Individuals with Type 1 Diabetes Mellitus: Contribution of Metabolic Syndrome.

    Science.gov (United States)

    Uribe-Wiechers, Ana Cecilia; Janka-Zires, Marcela; Almeda-Valdés, Paloma; López-Gutiérrez, Joel; Gómez-Pérez, Francisco J

    2015-01-01

    The development of metabolic syndrome has been described in patients with type 1 diabetes mellitus as the disease progresses over time. The purpose of this study is to assess the relationship between metabolic syndrome, albuminuria, and glomerular filtration rate, as well as to determine the prevalence of metabolic syndrome, in a group of Mexican patients with type 1 diabetes mellitus. We conducted a cross-sectional study that included patients with type 1 diabetes mellitus who were diagnosed over 10 years ago and who are seen at the Diabetes Intensive Control Clinic of the Instituto Nacional de Ciencias Medicas y Nutricion Salvador Zubiran in Mexico City. The presence of metabolic syndrome was determined by using the National Cholesterol Education Program-Adult Treatment Panel III (ATP III) criteria. A total of 81 individuals were studied. The prevalence of metabolic syndrome was 18.5% (n = 15). A higher albuminuria was found in subjects with metabolic syndrome (34.9 mg/24 hours; 8.3-169.3) than in those without metabolic syndrome (9.0 mg/24 hours; 5.0-27.0; p = 0.02). Glomerular filtration rate was lower in patients with metabolic syndrome (95.3 ml/minute; [64.9-107.2] vs. 110.2 ml/minute [88.1-120.3]; p = 0.04). After classifying the population according to the number of metabolic syndrome criteria, a progressive increase in albuminuria and a progressive decrease in glomerular filtration rate were found with each additional metabolic syndrome criterion (p = 0.008 and p = 0.032, respectively). After adjusting for age, time from diagnosis, systolic blood pressure, triglycerides, HDL-cholesterol, and treatment with angiotensin receptor blockers or angiotensin converting enzyme inhibitors, we found that age, time from diagnosis, triglycerides, and HDL-cholesterol were independent factors associated with glomerular filtration rate (R2 = 0.286; p diabetes mellitus. Metabolic syndrome was present in 18.5% of this group of Mexican individuals with type 1 diabetes

  14. Glomerular Filtration Rate Estimation in Renal and Non-Renal Solid Organ Transplantation

    DEFF Research Database (Denmark)

    Hornum, Mads; Feldt-Rasmussen, Bo

    2017-01-01

    Following transplantation (TX) of both renal and non-renal organs, a large proportion of patients have renal dysfunction. There are multiple causes for this. Chronic nephrotoxicity and high doses of calcineurin inhibitors are important factors. Preoperative and perioperative factors like...... or estimates of renal function in these patients, in order to accurately and safely dose immunosuppressive medication and perform and adjust the treatment and prophylaxis of renal dysfunction. This is a short overview and discussion of relevant studies and possible caveats of estimated glomerular filtration...... rate methods for use in renal and non-renal TX....

  15. Measurement of filtration efficiency of Nuclepore filters challenged with polystyrene latex nanoparticles: experiments and modeling

    International Nuclear Information System (INIS)

    Ling, Tsz Yan; Wang Jing; Pui, David Y. H.

    2011-01-01

    Membrane filtration has been demonstrated to be effective for the removal of liquid-borne nanoparticles (NPs). Such technique can be applied to purify and disinfect drinking water as well as remove NPs in highly pure chemicals used in the industries. This study aims to study the filtration process of a model membrane filter, the Nuclepore filter. Experiments were carried out using standard filtration tools and the nanoparticle tracking analysis (NTA) technique was used to measure particle (50–500 nm) concentration upstream and downstream of the filter to determine the filtration efficiency. The NTA technique has been calibrated using 150-nm polystyrene latex particles to determine its accuracy of particle concentration measurement. Measurements were found reliable within a certain concentration limit (about 10 8 –10 10 particles/cm 3 ), which is dependent on the camera settings during the measurement. Experimental results are comparable with previously published data obtained using the aerosolization method, validating the capability of the NTA technique. The capillary tube model modified from that developed for aerosol filtration was found to be useful to represent the experimental results, when a sticking coefficient of 0.15 is incorporated. This suggests that only 15% of the particle collisions with the filter results in successful attachment. The small sticking coefficient found can be explained by the unfavorable surface interactions between the particles and the filter medium.

  16. Evaluation of glomerular filtration rate of 99mTc-DTPA using PIP software

    International Nuclear Information System (INIS)

    Opazo, C.; Troncoso, M.; Gutierrez, E.; Guerrero, B.; Mena, J.

    2002-01-01

    Aim: Our purpose is to compare the measurement of glomerular filtration rate by DTPA Renogram (DTPA-GFR) using PIP software with those by 24-hour creatinine clearance (CC) in order to evaluate the results provided for the procedure and the software we used. The need for using this method well known from earlier eighties raised from the practical difficulties in getting an accurate CC in pediatric population specially in out patients as well as the fact there is not radiation, time, morbidity or discomfort added to the renogram. Methods: In a prospective study running from Sep-2001, up to now 18 patients aged 1 to 18 years underwent DTPA Renogram. DTPA-GFR was calculated from the renogram in a computer and PIP software system developed for the IAEA to be attached to analogical gammacameras The procedure involves 30 minutes DTPA renogram, full and empty DTPA syringe activity measure, input patient height and weight, to make ROIs around kidneys and background ROIs drawn below and in the lateral side of both kidneys. The results are provided automatically for the software using a kidney uptake index with Gates method. The results are expressed in ml/min for both and each kidney separately. No blood samples were used. All patients had CC measurement done at most 48 hours from the renogram using 24 hours urine collection and serum creatinine level. We make sure patients were well hydrated orally before starting renogram acquisition. Results: The DTPA-GFR mean was 81.6 ml/min (22.5-153.6). The CC mean was 78.8 ml/min (14.8-132). The comparison between DTPA-GFR and CC measurements showed an acceptable R2 coefficient (0.9228), a slope close to identity line (0.9504). The intercept was 6.75 ml/min and the T value was 0.2983. Conclusion: We have found an acceptable correlation between DTPA-GFR and CC with results obtained up to now. DTPA-GFR is a very easy procedure adding no extra time or cost to the renogram. The information provided can be useful to be considered by the

  17. Existing creatinine-based equations overestimate glomerular filtration rate in Indians.

    Science.gov (United States)

    Kumar, Vivek; Yadav, Ashok Kumar; Yasuda, Yoshinari; Horio, Masaru; Kumar, Vinod; Sahni, Nancy; Gupta, Krishan L; Matsuo, Seiichi; Kohli, Harbir Singh; Jha, Vivekanand

    2018-02-01

    Accurate estimation of glomerular filtration rate (GFR) is important for diagnosis and risk stratification in chronic kidney disease and for selection of living donors. Ethnic differences have required correction factors in the originally developed creatinine-based GFR estimation equations for populations around the world. Existing equations have not been validated in the vegetarian Indian population. We examined the performance of creatinine and cystatin-based GFR estimating equations in Indians. GFR was measured by urinary clearance of inulin. Serum creatinine was measured using IDMS-traceable Jaffe's and enzymatic assays, and cystatin C by colloidal gold immunoassay. Dietary protein intake was calculated by measuring urinary nitrogen appearance. Bias, precision and accuracy were calculated for the eGFR equations. A total of 130 participants (63 healthy kidney donors and 67 with CKD) were studied. About 50% were vegetarians, and the remainder ate meat 3.8 times every month. The average creatinine excretion were 14.7 mg/kg/day (95% CI: 13.5 to 15.9 mg/kg/day) and 12.4 mg/kg/day (95% CI: 11.2 to 13.6 mg/kg/day) in males and females, respectively. The average daily protein intake was 46.1 g/day (95% CI: 43.2 to 48.8 g/day). The mean mGFR in the study population was 51.66 ± 31.68 ml/min/1.73m 2 . All creatinine-based eGFR equations overestimated GFR (p < 0.01 for each creatinine based eGFR equation). However, eGFR by CKD-EPI Cys was not significantly different from mGFR (p = 0.38). The CKD-EPI Cys exhibited lowest bias [mean bias: -3.53 ± 14.70 ml/min/1.73m 2 (95% CI: -0.608 to -0.98)] and highest accuracy (P 30 : 74.6%). The GFR in the healthy population was 79.44 ± 20.19 (range: 41.90-134.50) ml/min/1.73m 2 . Existing creatinine-based GFR estimating equations overestimate GFR in Indians. An appropriately powered study is needed to develop either a correction factor or a new equation for accurate assessment of kidney function in the

  18. The giraffe kidney tolerates high arterial blood pressure by high renal interstitial pressure and low glomerular filtration rate

    DEFF Research Database (Denmark)

    Damkjær, Mads; Wang, T; Brøndum, E

    2015-01-01

    BACKGROUND: The tallest animal on earth, the giraffe (Giraffa camelopardalis) is endowed with a mean arterial blood pressure (MAP) twice that of other mammals. The kidneys reside at heart level and show no sign of hypertension-related damage. We hypothesized that a species-specific evolutionary...... cava generated a pressure drop of 12 ± 2 mmHg. RI was 0.27. The renal capsule was durable with a calculated burst pressure of 600 mmHg. Plasma renin and AngII were 2.6 ± 0.5 mIU L(-1) and 9.1 ± 1.5 pg mL(-1) respectively. CONCLUSION: In giraffes, GFR, ERPF and RI appear much lower than expected based...... adaption in the giraffe kidney allows normal for size renal haemodynamics and glomerular filtration rate (GFR) despite a MAP double that of other mammals. METHODS: Fourteen anaesthetized giraffes were instrumented with vascular and bladder catheters to measure glomerular filtration rate (GFR) and effective...

  19. Comparison of glomerular filtration rates derived from dynamic renal imaging and dual sample clearance in kidney transplantation

    International Nuclear Information System (INIS)

    Zhu Yangjun; Li Linfa; Zhang Jun; Du Xiaoying

    2007-01-01

    Objective: Glomerular filtration rate (GFR) is one of the valuable indictors of allograft status after kidney transplantation. The feasibility of an easy measurement of GFR by dynamic renal imaging (dGFR) was assessed in comparison to a classical dual plasma sample method (tGFR) in the current study for evaluating the function of grafting kidney. Methods: In 73 patients of kidney transplantation, both dynamic renal imaging and dual sample GFR measurement were undertaken after 99 Tc m -DTPA injection. The correlation between dGFR and tGFR, both being standardized according to surface area, was analyzed and the linear regression equation was obtained. Results: The mean dGFR was slightly lower than that of tGFR (t=-2.010, P<0.05). The dGFR correlated significantly with tGFR (r=0.759, P< 0.01). The linear regression equation was tGFR=0.6455 x dGFR + 25.514. Conclusion: The dGFR correlated well with tGFR and they were accurate in evaluating the filtration function of transplanted kidney. (authors)

  20. Aging and decreased glomerular filtration rate: An elderly population-based study.

    Directory of Open Access Journals (Sweden)

    Regina C R M Abdulkader

    Full Text Available Although a reduced glomerular filtration rate (GFR in old people has been attributed to physiologic aging, it may be associated with kidney disease or superimposed comorbidities. This study aims to assess the prevalence of decreased GFR in a geriatric population in a developing country and its prevalence in the absence of simultaneous diseases.This is a cross-sectional study of data from the Saúde, Bem-Estar e Envelhecimento cohort study (SABE study[Health, Well-Being and Aging], a multiple cohorts study. A multistage cluster sample composed of 1,253 individuals representative of 1,249,388 inhabitants of São Paulo city aged ≥60 years in 2010 was analyzed. The participants answered a survey on socio-demographic factors and health, had blood pressure measured and urine and blood samples collected. GFR was estimated and defined as decreased when 0.20 g/g.The prevalence of GFR <60 mL/min/1.73m2 was 19.3%. Individuals with GFR <60 mL/min/1.73m2 were older (75±1 versus 69±1 years, p<0.001, had lower schooling (18 versus 30% with complete 8-year basic cycle, p = 0.010, and higher prevalence of hypertension (82 versus 63%, p<0.001, diabetes (34 versus 26%, p = 0.021, cardiovascular disease (43 versus 24%, p<0.001 and kidney damage (35% versus 15%, p<0.001. Only 0.7% of the entire studied population had GFR <60 mL/min/1.73m2 without simultaneous diseases or kidney damage. Among the individuals with GFR <60 mL/min/1.73m2, 3.5% had neither renal damage nor associated comorbidities, whereas among those with GFR ≥60 mL/min/1.73m2, 11.0% had none of these conditions. Logistic regression showed that older age, cardiovascular disease and hypertension were associated with GFR<60 mL/min/1.73m2.Decreased GFR was highly prevalent among the geriatric population in a megalopolis of a developing country. It was rarely present without simultaneous chronic comorbidities or kidney damage.

  1. Comparison of glomerular filtration rates by dynamic renal scintigraphy and dual-plasma sample clearance method in diabetic nephropathy

    International Nuclear Information System (INIS)

    Xie Peng; Huang Jianmin; Pan Liping; Liu Xiaomei; Wei Lingge; Gao Jianqing

    2010-01-01

    Objective: To evaluate the accuracy of renal scintigraphy for the estimation of glomerular filtration rates (dGFR) in patients with diabetic nephropathy as compared to the conventional dual-plasma sample clearance method (pscGFR). Methods: Forty-six patients with diabetic nephropathy underwent both dynamic renal scintigraphy and dual-plasma sample measurement after 99 Tc m -DTPA injection. Paired student t-test and correlation analysis were performed to compare dGFR and pscGFR (normalized to body surface area, 1.73 m -2 ). Results: The mean dGFR was higher than mean pscGFR ((51.08±26.78)ml·min -1 vs (44.06±29.43)ml·min -1 , t=4.209, P=0.000). The dGFR correlated with pscGFR (r=0.923, P=0.000) linearly (regression equation: pscGFR=1.015 x dGFR -7.773, F=254.656, P=0.000). Conclusions: dGFR correlated well with pscGFR. Although it could not absolutely replace the latter in patients with diabetic nephropathy, dGFR could reasonably evaluate the filtration function for these patients. (authors)

  2. Aging and physiological changes of the kidneys including changes in glomerular filtration rate.

    Science.gov (United States)

    Musso, Carlos G; Oreopoulos, Dimitrios G

    2011-01-01

    In addition to the structural changes in the kidney associated with aging, physiological changes in renal function are also found in older adults, such as decreased glomerular filtration rate, vascular dysautonomia, altered tubular handling of creatinine, reduction in sodium reabsorption and potassium secretion, and diminished renal reserve. These alterations make aged individuals susceptible to the development of clinical conditions in response to usual stimuli that would otherwise be compensated for in younger individuals, including acute kidney injury, volume depletion and overload, disorders of serum sodium and potassium concentration, and toxic reactions to water-soluble drugs excreted by the kidneys. Additionally, the preservation with aging of a normal urinalysis, normal serum urea and creatinine values, erythropoietin synthesis, and normal phosphorus, calcium and magnesium tubular handling distinguishes decreased GFR due to normal aging from that due to chronic kidney disease. Copyright © 2011 S. Karger AG, Basel.

  3. Current use of equations for estimating glomerular filtration rate in Spanish laboratories.

    Science.gov (United States)

    Gràcia-Garcia, Sílvia; Montañés-Bermúdez, Rosario; Morales-García, Luis J; Díez-de Los Ríos, M José; Jiménez-García, Juan Á; Macías-Blanco, Carlos; Martínez-López, Rosalina; Ruiz-Altarejos, Joaquín; Ruiz-Martín, Guadalupe; Sanz-Hernández, Sonia; Ventura-Pedret, Salvador

    2012-07-17

    In 2006 the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) and the Spanish Society of Nephrology (S.E.N.) developed a consensus document in order to facilitate the diagnosis and monitoring of chronic kidney disease with the incorporation of equations for estimating glomerular filtration rate (eGFR) into laboratory reports. The current national prevalence of eGFR reporting and the degree of adherence to these recommendations among clinical laboratories is unknown. We administered a national survey in 2010-11 to Spanish clinical laboratories. The survey was through e-mail or telephone to laboratories that participated in the SEQC’s Programme for External Quality Assurance, included in the National Hospitals Catalogue 2010, including both primary care and private laboratories. A total of 281 laboratories answered to the survey. Of these, 88.2% reported on the eGFR, with 61.9% reporting on the MDRD equation and 31.6% using the MDRD-IDMS equation. A total of 42.5% of laboratories always reported serum creatinine values, and other variables only when specifically requested. Regarding the way results were presented, 46.2% of laboratories reported the exact numerical value only when the filtration rate was below 60mL/min/1.73m2, while 50.6% reported all values regardless. In 56.3% of the cases reporting eGFR, an interpretive commentary of it was enclosed. Although a high percentage of Spanish laboratories have added eGFR in their reports, this metric is not universally used. Moreover, some aspects, such as the equation used and the correct expression of eGFR results, should be improved.

  4. Predictors of estimated glomerular filtration rate progression, stabilization or improvement after chronic renal impairment in HIV-positive individuals

    DEFF Research Database (Denmark)

    Ryom, Lene; Mocroft, Amanda; Kirk, Ole

    2017-01-01

    OBJECTIVES: The objectives of this analysis were to investigate predictors of progression, stabilization or improvement in estimated glomerular filtration rate (eGFR) after development of chronic renal impairment (CRI) in HIV-positive individuals. DESIGN: Prospective observational study. METHODS......: The Data Collection on Adverse events of Anti-HIV Drugs (D:A:D) study participants progressing to CRI defined as confirmed, at least 3 months apart, and eGFR 70 ml/min per 1.73 m or less were included in the analysis. The median of all eGFRs measured 24-36 months post-CRI was compared with the median e......GFR defining CRI, and changes were grouped into improvement (>+10 ml/min per 1.73 m), stabilization (-10 to +10 ml/min per 1.73 m) and progression (

  5. Recombinant human erythropoietin in humans down-regulates proximal renal tubular reabsorption and causes a fall in glomerular filtration rate

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Aachmann-Andersen, Niels Jacob; Oturai, Peter

    2010-01-01

    HuEPO for 28 days in doses raising the hematocrit to 48.3 (4.1) %. Renal clearance studies with urine collections (N = 8) were done at baseline and at days 4, 11, 29, and 42. Glomerular filtration rate (GFR) was measured by (51)Cr-EDTA. Renal clearance of lithium (C(Li)) was used as an index of proximal...... tubular outflow and to assess segmental renal tubular handling of sodium and water. rHuEPO-induced increases in hematocrit occurred from day 10 onwards and was caused by both an increase in red cell volume and a fall in plasma volume. Well before that (from day 2 and throughout the treatment time), r...... and water (APR = GFR - C(Li), P

  6. Comparison of methods for estimating glomerular filtration rate in head and neck cancer patients treated with cisplatin

    DEFF Research Database (Denmark)

    Lindberg, Lotte; Brødbæk, Kasper; Hägerström, Erik G

    2017-01-01

    Cisplatin is a chemotherapeutic agent widely used in the treatment of various solid tumors. Cisplatin induces nephrotoxicity and may lead to long-term reduction of kidney function. Consequently, determination of glomerular filtration rate (GFR) is used to monitor potential kidney damage. This study...... aimed to compare two commonly used algorithms for estimating GFR (eGFR) from plasma creatinine (PCr) with 51Cr-EDTA clearance (CrCl) as a reference method. This was a retrospective single center study of 94 head and neck cancer patients treated with cisplatin. CrCl was performed once before, during......, and after treatment, and PCr was measured concurrently. eGFR was assessed from PCr applying the Cockcroft-Gault (CG) and the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations. Agreement was assessed applying the statistical methods of Bland and Altman. A predefined limit of clinically...

  7. Variability of glomerular filtration rate estimation equations in elderly Chinese patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Liu X

    2012-10-01

    Full Text Available Xun Liu,1,2,* Mu-hua Cheng,3,* Cheng-gang Shi,1 Cheng Wang,1 Cai-lian Cheng,1 Jin-xia Chen,1 Hua Tang,1 Zhu-jiang Chen,1 Zeng-chun Ye,1 Tan-qi Lou11Division of Nephrology, Department of Internal Medicine, The Third Affiliated Hospital of Sun Yet-sun University, Guangzhou, China; 2College of Biology Engineering, South China University of Technology, Guangzhou, China; 3Department of Nuclear Medicine, The Third Affiliated Hospital of Sun Yet-sun University, Guangzhou, China *These authors contributed equally to this paperBackground: Chronic kidney disease (CKD is recognized worldwide as a public health problem, and its prevalence increases as the population ages. However, the applicability of formulas for estimating the glomerular filtration rate (GFR based on serum creatinine (SC levels in elderly Chinese patients with CKD is limited.Materials and methods: Based on values obtained with the technetium-99m diethylenetriaminepentaacetic acid (99mTc-DTPA renal dynamic imaging method, 319 elderly Chinese patients with CKD were enrolled in this study. Serum creatinine was determined by the enzymatic method. The GFR was estimated using the Cockroft–Gault (CG equation, the Modification of Diet in Renal Disease (MDRD equations, the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equation, the Jelliffe-1973 equation, and the Hull equation.Results: The median of difference ranged from −0.3–4.3 mL/min/1.73 m2. The interquartile range (IQR of differences ranged from 13.9–17.6 mL/min/1.73 m2. Accuracy with a deviation less than 15% ranged from 27.6%–32.9%. Accuracy with a deviation less than 30% ranged from 53.6%–57.7%. Accuracy with a deviation less than 50% ranged from 74.9%–81.5%. None of the equations had accuracy up to the 70% level with a deviation less than 30% from the standard glomerular filtration rate (sGFR. Bland–Altman analysis demonstrated that the mean difference ranged from −3.0–2.4 mL/min/1.73 m2. However, the

  8. Effects of atrial natriuretic peptide on glomerular filtration rate in essential hypertension: A radionuclide study

    Energy Technology Data Exchange (ETDEWEB)

    Cuocolo, A.; Volpe, M.; Mele, A.F.; Celentano, L.; Neumann, R.D.; Trimarco, B.; Salvatore, M. (Naples Univ. (Italy). Ist. di Scienze Radiologiche Istituto Nazionale dei Tumori, Naples (Italy))

    1991-01-01

    A number of studies show that atrial natriuretic peptide (ANP) raises renal sodium excretion with a concomitant increase in glomerular filtration rate (GFR) in both experimental animals and normal humans. Studies using indirect evaluation of GFR have provided less consistent results in hypertensive patients. We studied the effects of intravenously administered (iv) {alpha}-human ANP on GFR in patients with hypertension by a radionuclide technique using technetium 99m diethylenetriaminepenta-acetic acid. In six patients (ANP group), GFR was determined under control conditions, during iv ANP (initial bolus of 0.5 {mu}g/kg followed by a 21-min maintenance infusion at 0.05 {mu}g.kg{sup -1}.min{sup -1}) and during a recovery phase. In six other patients (control group), GFR was determined under control conditions, during saline iv infusion and during recovery. The two groups did not differ with respect to age, sex, basal blood pressure, heart rate or GFR. In the ANP group, the infusion of the peptide induced a significant decrease of mean blood pressure (from 133+-5 to 120+-5 mmHg, P<0.01), no change in heart rate and a significant increase in GFR (from 104+-4 to 125+-5 ml/min, P<0.01). During recovery, blood pressure, heart rate and GFR were not different from the values recorded under control conditions. No changes in blood pressure, heart rate or GFR (from 106+-5 to 108+-5 ml/min, n.s.) were detected during saline infusion in the control group. Our results demonstrated that in patients with essential hypertension, ANP induces an augmentation in GFR in spite of a decrease in blood pressure; this suggests a unique role for atrial peptide-related drugs in the treatment of human hypertension. (orig.).

  9. Automating and estimating glomerular filtration rate for dosing medications and staging chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Trinkley KE

    2014-05-01

    Full Text Available Katy E Trinkley,1 S Michelle Nikels,2 Robert L Page II,1 Melanie S Joy11Skaggs School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, University of Colorado, Aurora, CO, USA Objective: The purpose of this paper is to serve as a review for primary care providers on the bedside methods for estimating glomerular filtration rate (GFR for dosing and chronic kidney disease (CKD staging and to discuss how automated health information technologies (HIT can enhance clinical documentation of staging and reduce medication errors in patients with CKD.Methods: A nonsystematic search of PubMed (through March 2013 was conducted to determine the optimal approach to estimate GFR for dosing and CKD staging and to identify examples of how automated HITs can improve health outcomes in patients with CKD. Papers known to the authors were included, as were scientific statements. Articles were chosen based on the judgment of the authors.Results: Drug-dosing decisions should be based on the method used in the published studies and package labeling that have been determined to be safe, which is most often the Cockcroft–Gault formula unadjusted for body weight. Although Modification of Diet in Renal Disease is more commonly used in practice for staging, the CKD–Epidemiology Collaboration (CKD–EPI equation is the most accurate formula for estimating the CKD staging, especially at higher GFR values. Automated HITs offer a solution to the complexity of determining which equation to use for a given clinical scenario. HITs can educate providers on which formula to use and how to apply the formula in a given clinical situation, ultimately improving appropriate medication and medical management in CKD patients.Conclusion: Appropriate estimation of GFR is key to optimal health outcomes. HITs assist clinicians in both choosing the most appropriate GFR estimation formula and in applying the results of the GFR estimation in practice. Key limitations of the

  10. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay

    NARCIS (Netherlands)

    Kemperman, F. A.; Silberbusch, J.; Slaats, E. H.; van Zanten, A. P.; Weber, J. A.; Krediet, R. T.; Arisz, L.

    1999-01-01

    BACKGROUND: Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this

  11. A comparison between cystatin C, plasma creatinine and the Cockcroft and Gault formula for the estimation of glomerular filtration rate

    NARCIS (Netherlands)

    Hoek, Frans J.; Kemperman, Frits A. W.; Krediet, Raymond T.

    2003-01-01

    BACKGROUND: In clinical practice, the glomerular filtration rate (GFR) is often estimated from plasma creatinine. Several studies have shown cystatin C (cys C) to be a better parameter for the diagnosis of impaired renal function. No data are available, however, on the performance of cys C in

  12. Salt sensitivity of renin secretion, glomerular filtration rate and blood pressure in conscious Sprague-Dawley rats

    DEFF Research Database (Denmark)

    Isaksson, G L; Stubbe, J; Hansen, Per Lyngs

    2014-01-01

    We hypothesized that in normal rats in metabolic steady state, (i) the plasma renin concentration (PRC) is log-linearly related to Na(+) intake (NaI), (ii) the concurrent changes in mean arterial pressure (MABP) and glomerular filtration rate (GFR) are negligible and (iii) the function PRC...

  13. Estimating glomerular filtration rate: Cockcroft-Gault and Modification of Diet in Renal Disease formulas compared to renal inulin clearance.

    NARCIS (Netherlands)

    Botev, R.; Mallie, J.P.; Couchoud, C.; Schuck, O.; Fauvel, J.P.; Wetzels, J.F.M.; Lee, N.; Santo, N.G. De; Cirillo, M.

    2009-01-01

    BACKGROUND AND OBJECTIVES: Evaluation of renal function by estimation of the glomerular filtration rate (GFR) is very important for the diagnosis and treatment of patients with chronic kidney disease (CKD). The Cockcroft-Gault (CG) and Modification of Diet in Renal Disease (MDRD) formulas are the

  14. Preliminary Findings of Serum Creatinine and Estimated Glomerular Filtration Rate (eGFR) in Adolescents with Intellectual Disabilities

    Science.gov (United States)

    Lin, Jin-Ding; Lin, Lan-Ping; Hsieh, Molly; Lin, Pei-Ying

    2010-01-01

    The present study aimed to describe the kidney function profile--serum creatinine and estimated glomerular filtration rate (eGFR), and to examine the relationships of predisposing factors to abnormal serum creatinine in people with intellectual disabilities (ID). Data were collected by a cross-sectional study of 827 aged 15-18 years adolescents…

  15. Beta thalassemia major: The effect of age on glomerular filtration rate

    Directory of Open Access Journals (Sweden)

    Majid Malaki

    2011-01-01

    Full Text Available Thalassemia is a common hereditary hemoglobinopathy disorder that affects many organs in the body. Estimation of kidney function is important, as it is the vital organ that plays the major role in the elimination of accumulated iron as well as the chelating drugs that have to be used as therapy. Sixty- three patients aged 1-29 years, with a mean ± SD of 14 ± 6.7 years, affected with beta- thalassemia major in Tabriz Children′s Hospital were evaluated for their renal function on the basis of their age, serum iron, serum ferritin and serum creatinine levels along with two methods of estimating glomerular filtration rate (GFR; by Schwartz method for those under 18 years old and using Modification of Diet in Renal Disease (MDRD formula for those who were 18 years and above. Elevation of serum creatinine denoting renal dysfunction was not seen in our patients, but hyperfiltration was a common finding. An increasing GFR was observed, which corresponded to age, but no relationships were seen between serum iron, serum ferritin, regular blood transfusion, chelating therapy to GFR.

  16. Effect angiotensin II receptor blockers on glomerular filtration rate in patients with incipient diabetic nephropathy

    International Nuclear Information System (INIS)

    Dragovic, T.; Ajdinovic, B.; Endocrinology Clinic

    2004-01-01

    Glomerular filtration rate (GFR) was calculated in patients with incipient diabetic nephropathy with an aim to evaluate the effect of angiotensin receptor blockator valsartan on GFR stabilisation to physiological levels. Investigation was done as a prospective, randomised, placebo controlled study, on 20 patients with diabetes mellitus, type I (age 25 years, disease lasting 14 years). In all patients was detected incipient diabetic nephropathy with daily urinary albumin excretion in range from 30 mg to 300 mg. Patients were randomised in two groups: 10 patients were treated with 80 mg /day valsartan, during 6 months, second group (10 patients) were on placebo at the same period. GFR, as a clearance of 51Cr-EDTA, was calculated at the start and at the end of the study. In the first patients group during investigation period, GFR was decreased from 150, 1 ml/min/1.73m 2 to physiological level of 127 ml/min/1,73m 2 (p 2 at the start, 139,9 ml/min/l.73m 2 at the end of the study).On the basis of these results it was concluded that 80 mg/day in 6 month valsartan therapy decreased GFR to physiological levels in patients with incipient diabetic nephropathy. (authors)

  17. Glomerular filtration rate and functional decline in an acute geriatric unit

    Directory of Open Access Journals (Sweden)

    Ocampo Chaparro, José Mauricio

    2018-01-01

    Full Text Available Introduction: Low estimated Glomerular filtration rate (eGFR is associated with functional decline. Little is known on that association in hospitalized elderly. Objective: Determine if low eGFR is associated with functional decline. Methods: Prospective cohort study that included 1826 patients 60 years and older hospitalized in a Geriatric Acute Unit, admitted between January 2012 and August 2015. The outcome was functional status assessed four times by the Barthel Index (BI. Kidney function was estimated by MDRD-4 IDMS and was grouped into four categories according to eGFR (normal ≥90, mild 60-89, moderate 59-30, severe <30. Multivariate logistic regression models and GLIMMIX procedure for longitudinal analyzes were used. Results: Mean age was 82.3±7.2 years, 51 % were women. In multivariate logistic regression, a BI≤60 at admission was associated with age ≥80, female gender, high comorbidity, social deterioration, hypoalbuminemia, anemia, MMSE<19, while the presence of mild or moderate renal failure reduced this risk. In the longitudinal analysis, lower total BI at follow-up was associated with age ≥80, female gender, social deterioration, hospital stay ≥15 days, high comorbidity, hypoalbuminemia, MMSE<19. The presence of mild, moderate or severe renal impairment was associated with higher BI over time. Conclusions: A low eGFR was associated with lower risk for functional decline at admission and overtime. These findings differ from previous reports in the literature.

  18. Estimated glomerular filtration rate function in patients with and without metabolic syndrome

    Directory of Open Access Journals (Sweden)

    María E Lizardo

    2016-06-01

    Full Text Available Introduction: Metabolic syndrome (MS is an independent risk factor, which affects the development of chronic kidney disease, so the glomerular filtration rate (GFR as an indicator of glomerular function in patients with and without MS who attended the outpatient clinic “los Grillitos, sector Caña de Azucar”. Materials and Methods: A comparative, correlational, cross-sectional study was conducted in a non-probability sample of convenience consisting of 60 patients with MS diagnosed according to the criteria Panel ATP III, and 60 apparently healthy individuals, whom the GFR was determined by the Cockcroft-Gault as well as clinical and biochemical parameters for the diagnosis of MS. Results: Out of the total patients evaluated, 37 (30.7% showed alterations that put them in grades G2 and G3 system risk stratification of CKD, of these 18 and 19 corresponded to patients with and without MS respectively. Glomerular Hyperfiltration (> 120 mil / min it was found in both groups 28 (46.7% and 24 (40% cases of patients with and without MS respectively. The glomerular function was strongly correlated with abdominal obesity and high levels of stress arterial. As for the number of criteria and its relationship to the level of kidney damage present, not a firm to increase the latter with respect to the first (p=0.385 trend was observed. Conclusion: The change in the glomerular function is not directly related to the MS but with its components, specifically abdominal obesity and hypertension.

  19. Effect of benazepril and robenacoxib and their combination on glomerular filtration rate in dogs.

    Science.gov (United States)

    Panteri, A; Kukk, A; Desevaux, C; Seewald, W; King, J N

    2017-01-01

    Combined use of angiotensin-converting enzyme inhibitors and nonsteroidal anti-inflammatory drugs may induce acute kidney injury, especially when combined with diuretics. The objective of this investigation was to evaluate the effect of benazepril, robenacoxib and their combination in healthy dogs. In each of two studies (studies 1 and 2), 32 beagle dogs were randomized into one of four groups in a parallel-group design. Groups received once-daily oral treatment for 7 days with placebo, benazepril, robenacoxib or benazepril plus robenacoxib. In study 2, all dogs received additionally 2 mg/kg furosemide orally twice daily. The primary endpoint was the glomerular filtration rate (GFR) estimated from the plasma clearance of iohexol. Secondary endpoints included standard clinical monitoring and, in study 2, plasma renin activity, urine volume, specific gravity and aldosterone concentration and water intake. Administration of furosemide induced diuresis, reduced GFR and activated the renin-aldosterone-angiotensin system. Benazepril and robenacoxib, administered alone or in combination, were tolerated well, did not decrease GFR with or without co-administration of furosemide and significantly reduced urinary aldosterone concentrations. No increased risk of acute kidney injury was identified with the combination of benazepril and robenacoxib in healthy dogs. Different effects might occur in dogs with heart or renal disease. © 2016 The Authors. Journal of Veterinary Pharmacology and Therapeutics Published by John Wiley & Sons Ltd.

  20. Prediction of hospital mortality by changes in the estimated glomerular filtration rate (eGFR).

    LENUS (Irish Health Repository)

    Berzan, E

    2015-03-01

    Deterioration of physiological or laboratory variables may provide important prognostic information. We have studied whether a change in estimated glomerular filtration rate (eGFR) value calculated using the (Modification of Diet in Renal Disease (MDRD) formula) over the hospital admission, would have predictive value. An analysis was performed on all emergency medical hospital episodes (N = 61964) admitted between 1 January 2002 and 31 December 2011. A stepwise logistic regression model examined the relationship between mortality and change in renal function from admission to discharge. The fully adjusted Odds Ratios (OR) for 5 classes of GFR deterioration showed a stepwise increased risk of 30-day death with OR\\'s of 1.42 (95% CI: 1.20, 1.68), 1.59 (1.27, 1.99), 2.71 (2.24, 3.27), 5.56 (4.54, 6.81) and 11.9 (9.0, 15.6) respectively. The change in eGFR during a clinical episode, following an emergency medical admission, powerfully predicts the outcome.

  1. Effect of creatinine assay calibration on glomerular filtration rate prediction by MDRD equation

    Directory of Open Access Journals (Sweden)

    Débora Spessatto

    2009-01-01

    Full Text Available Background: The evaluation of renal function should be performed with glomerular filtration rate (GFR estimation employing the Modification of Diet in Renal Disease (MDRD study equation, which includes age, gender, ethnicity and serum creatinine. However, creatinine methods require traceability with standardized methods. Objective: To analyse the impact of creatinine calibration on MDRD calculated GFR. Methods: 140 samples of plasma with creatinine values <2,0 mg/dl were analysed by Jaffé’s reaction with Creatinina Modular P (Roche ®; method A; reference and Creatinina Advia 1650 (Bayer ®; method B; non-standardized. The results with the different methods were compared and aligned with standardized method through a conversion formula. MDRD GFR was estimated. Results: Values were higher for method B (1.03 ± 0.29 vs. 0.86 ± 0.32 mg/dl, P<0.001. This difference declined when methods were aligned with the equation y=1.07x -0.249, and the aligned values were 0,9 ± 0,31 mg/dl. Non-traceable creatinine methods misclassificaed chronic kidney disease in 10% more (false positive. This disagreement disappeared after the regression alignment. Conclusion: Creatinine method calibration has a large impact over the final results of serum creatinine and GFR. The alignment of the non-standardized results through conversion formulas is a reasonable alternative to harmonize serum creatinine results while waiting for the full implementation of international  standardization programs.

  2. Technical note: Use of a simplified equation for estimating glomerular filtration rate in beef cattle.

    Science.gov (United States)

    Murayama, I; Miyano, A; Sasaki, Y; Hirata, T; Ichijo, T; Satoh, H; Sato, S; Furuhama, K

    2013-11-01

    This study was performed to clarify whether a formula (Holstein equation) based on a single blood sample and the isotonic, nonionic, iodine contrast medium iodixanol in Holstein dairy cows can apply to the estimation of glomerular filtration rate (GFR) for beef cattle. To verify the application of iodixanol in beef cattle, instead of the standard tracer inulin, both agents were coadministered as a bolus intravenous injection to identical animals at doses of 10 mg of I/kg of BW and 30 mg/kg. Blood was collected 30, 60, 90, and 120 min after the injection, and the GFR was determined by the conventional multisample strategies. The GFR values from iodixanol were well consistent with those from inulin, and no effects of BW, age, or parity on GFR estimates were noted. However, the GFR in cattle weighing less than 300 kg, aged<1 yr old, largely fluctuated, presumably due to the rapid ruminal growth and dynamic changes in renal function at young adult ages. Using clinically healthy cattle and those with renal failure, the GFR values estimated from the Holstein equation were in good agreement with those by the multisample method using iodixanol (r=0.89, P=0.01). The results indicate that the simplified Holstein equation using iodixanol can be used for estimating the GFR of beef cattle in the same dose regimen as Holstein dairy cows, and provides a practical and ethical alternative.

  3. Filtration by eyelashes

    Science.gov (United States)

    Vistarakula, Krishna; Bergin, Mike; Hu, David

    2010-11-01

    Nearly every mammalian and avian eye is rimmed with lashes. We investigate experimentally the ability of lashes to reduce airborne particle deposition in the eye. We hypothesize that there is an optimum eyelash length that maximizes both filtration ability and extent of peripheral vision. This hypothesis is tested using a dual approach. Using preserved heads from 36 species of animals at the American Museum of Natural History, we determine the relationship between eye size and eyelash geometry (length and spacing). We test the filtration efficacy of these geometries by deploying outdoor manikins and measuring particle deposition rate as a function of eyelash length.

  4. Influence of the rate of filtration of a complexly alloyed nickel melt through a foam-ceramic filter on the sulfur impurity content in the metal

    Science.gov (United States)

    Sidorov, V. V.; Min, P. G.; Folomeikin, Yu. I.; Vadeev, V. E.

    2015-06-01

    The article discusses the possibility of additional refining of a complexly alloyed nickel melt from a sulfur impurity by decreasing the filtration rate during the passage of the melt through a foam-ceramic filter. The degree of sulfur removal from the melt is shown to depend on its content in the alloy and the melt filtration rate.

  5. Effects of levosimendan on glomerular filtration rate, renal blood flow, and renal oxygenation after cardiac surgery with cardiopulmonary bypass: a randomized placebo-controlled study.

    Science.gov (United States)

    Bragadottir, Gudrun; Redfors, Bengt; Ricksten, Sven-Erik

    2013-10-01

    Acute kidney injury develops in a large proportion of patients after cardiac surgery because of the low cardiac output syndrome. The inodilator levosimendan increases cardiac output after cardiac surgery with cardiopulmonary bypass, but a detailed analysis of its effects on renal perfusion, glomerular filtration, and renal oxygenation in this group of patients is lacking. We therefore evaluated the effects of levosimendan on renal blood flow, glomerular filtration rate, renal oxygen consumption, and renal oxygen demand/supply relationship, i.e., renal oxygen extraction, early after cardiac surgery with cardiopulmonary bypass. Prospective, placebo-controlled, and randomized trial. Cardiothoracic ICU of a tertiary center. Postcardiac surgery patients (n=30). The patients were randomized to receive levosimendan, 0.1 µg/kg/min after a loading dose of 12 µg/kg (n=15), or placebo (n=15). The experimental procedure started 4-6 hours after surgery in the ICU during propofol sedation and mechanical ventilation. Systemic hemodynamic were evaluated by a pulmonary artery thermodilution catheter. Renal blood flow and glomerular filtration rate were measured by the renal vein retrograde thermodilution technique and by renal extraction of Cr-EDTA, respectively. Central venous pressure was kept constant by colloid/crystalloid infusion. Compared to placebo, levosimendan increased cardiac index (22%), stroke volume index (15%), and heart rate (7%) and decreased systemic vascular resistance index (21%), whereas mean arterial pressure was not affected. Levosimendan induced significant increases in renal blood flow (12%, prenal vascular resistance (18%, prenal oxygen consumption, or renal oxygen extraction, compared to placebo. After cardiac surgery with cardiopulmonary bypass, levosimendan induces a vasodilation, preferentially of preglomerular resistance vessels, increasing both renal blood flow and glomerular filtration rate without jeopardizing renal oxygenation. Due to its

  6. Circulating CD34-positive cells, glomerular filtration rate and triglycerides in relation to hypertension.

    Science.gov (United States)

    Shimizu, Yuji; Sato, Shimpei; Koyamatsu, Jun; Yamanashi, Hirotomo; Nagayoshi, Mako; Kadota, Koichiro; Maeda, Takahiro

    2015-11-01

    Serum triglycerides have been reported to be independently associated with the development of chronic kidney disease (CKD), which is known to play a role in vascular disturbance. On the other hand, circulating CD34-positve cells, including endothelial progenitor cells, are reported to contribute to vascular repair. However, no studies have reported on the correlation between triglycerides and the number of CD34-positive cells. Since hypertension is well known factor for vascular impairment, the degree of correlation between serum triglycerides and circulating CD34-positve cells should account for hypertension status. We conducted a cross-sectional study of 274 elderly Japanese men aged ≥ 60 years (range 60-79 years) undergoing general health checkups. Multiple linear regression analysis of non-hypertensive subjects adjusting for classical cardiovascular risk factors showed that although triglyceride levels (1SD increments; 64 mg/dL) did not significantly correlate with glomerular filtration rate (GFR) (β = -2.06, p = 0.163), a significant positive correlation was seen between triglycerides and the number of circulating CD34-positive cells (β = 0.50, p = 0.004). In hypertensive subjects, a significant inverse correlation between triglycerides and GFR was observed (β = -2.66, p = 0.035), whereas no significant correlation between triglycerides and the number of circulating CD34-positive cells was noted (β = -0.004, p = 0.974). Since endothelial progenitor cells (CD34-positive cells) have been reported to contribute to vascular repair, our results indicate that in non-hypertensive subjects, triglycerides may stimulate an increase in circulating CD34-positive cells (vascular repair) by inducing vascular disturbance. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Water-soluble vitamins in people with low glomerular filtration rate or on dialysis: a review.

    Science.gov (United States)

    Clase, Catherine M; Ki, Vincent; Holden, Rachel M

    2013-01-01

    People with low glomerular filtration rate and people on dialysis are spontaneously at risk for vitamin deficiency because of the potential for problems with decreased appetite and decreased sense of smell and taste, leading to decreased intake, and because decreased energy or decreased cognitive ability results in difficulties in shopping and cooking. Imposed dietary restrictions because of their renal dysfunction and because of comorbidities such as hypertension and diabetes exacerbate this problem. Finally, particularly for water-soluble vitamins, loss may occur into the dialysate. We did not identify any randomized trials of administering daily doses close to the recommended daily allowances of these vitamins. In people who are eating at all, deficiencies of B5 and B7 seem unlikely. It is unclear whether supplements of B2 and B3 are necessary. Because of dialyzability and documented evidence of insufficiency in dialysis patients, B1 supplementation is likely to be helpful. B6, B9, and B12 are implicated in the hyperhomocysteinemia observed in patients on dialysis. These vitamins have been studied in combinations, in high doses, with the hope of reducing cardiovascular outcomes. No reductions in patient-important outcomes were seen in adequately powered randomized trials. Because of their involvement in the homocysteine pathway, however, supplementation with lower doses, close to the recommended daily allowances, may be helpful. Vitamin C deficiency is common in patients on dialysis who are not taking supplements: low-dose supplements are warranted. Vitamins for dialysis patients contain most or all of the B vitamins and low-dose vitamin C. We are not aware of any medical reasons to choose one over another. © 2013. The Authors. Seminars in Dialysis published by Wiley Periodicals, Inc.

  8. Correlation of Serum Cystatin C with Glomerular Filtration Rate in Patients Receiving Platinum-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Ernesta Cavalcanti

    2016-01-01

    Full Text Available Objectives. Serum cystatin C seems to be an accurate marker of glomerular filtration rate (GFR compared to serum creatinine. The aim of this work was to explore the possibility of using serum cystatin C instead of serum creatinine to early predict renal failure in cancer patients who received platinum based chemotherapy. Design and Methods. Serum creatinine, serum cystatin C concentrations, and GFR were determined simultaneously in 52 cancer patients received carboplatin-based or cisplatin-based chemotherapy. Serum creatinine was assayed on Cobas C6000-Roche, serum cystatin C assay was performed on AIA 360-Tosoh, and GFR was determined in all patients, before the first cycle of chemotherapy and before the subsequent administrations. Results. In the overall series, for the prediction of a fall of GFR < 80 mL/min/1.73 m2, the AUC of the ROC curve for cystatin C was 0,667 and the best threshold was 1.135 mg/L (sensitivity 90.5%, specificity 61.1%. For a GFR fall < 60 mL/min/1.73 m2, the AUC of ROC curve for cystatin C was 74.3% and the best threshold was 1.415 mg/L (sensitivity 66.7%, specificity 73.2%. Conclusions. Baseline cystatin C values were not able to predict renal failure during subsequent treatment. In conclusion, serum cystatin C is not a reliable early marker to efficiently predict renal failure in patients receiving chemotherapy.

  9. Measurement-Based Evaluation of Installed Filtration System Performance in Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu Rengie; Singer, Brett C.

    2014-04-03

    This guide discusses important study design issues to consider when conducting an on-site evaluation of filtration system performance. The two most important dichotomies to consider in developing a study protocol are (1) whether systems are being evaluated in occupied or unoccupied homes and (2) whether different systems are being compared in the same homes or if the comparison is between systems installed in different homes. This document provides perspective and recommendations about a suite of implementation issues including the choice of particle measurement devices, selection of sampling locations, ways to control and/or monitor factors and processes that can impact particle concentrations, and data analysis approaches.

  10. Continuous improvements of defectivity rates in immersion photolithography via functionalized membranes in point-of-use photochemical filtration

    Science.gov (United States)

    D'Urzo, Lucia; Bayana, Hareen; Vandereyken, Jelle; Foubert, Philippe; Wu, Aiwen; Jaber, Jad; Hamzik, James

    2017-03-01

    Specific "killer-defects", such as micro-line-bridges are one of the key challenges in photolithography's advanced applications, such as multi-pattern. These defects generate from several sources and are very difficult to eliminate. Pointof-use filtration (POU) plays a crucial role on the mitigation, or elimination, of such defects. Previous studies have demonstrated how the contribution of POU filtration could not be studied independently from photoresists design and track hardware settings. Specifically, we investigated how an effective combination of optimized photoresist, filtration rate, filtration pressure, membrane and device cleaning, and single and multilayer filter membranes at optimized pore size could modulate the occurrence of such defects [1, 2, 3 and 4]. However, the ultimate desired behavior for POU filtration is the selective retention of defect precursor molecules contained in commercially available photoresist. This optimal behavior can be achieved via customized membrane functionalization. Membrane functionalization provides additional non-sieving interactions which combined with efficient size exclusion can selectively capture certain defect precursors. The goal of this study is to provide a comprehensive assessment of membrane functionalization applied on an asymmetric ultra-high molecular weight polyethylene (UPE) membrane at different pore size. Defectivity transferred in a 45 nm line 55 nm space (45L/55S) pattern, created through 193 nm immersion (193i) lithography with a positive tone chemically amplified resist (PT-CAR), has been evaluated on organic under-layer coated wafers. Lithography performance, such as critical dimensions (CD), line width roughness (LWR) and focus energy matrix (FEM) is also assessed.

  11. Reduced glomerular filtration rate and its association with clinical outcome in older patients at risk of vascular events: secondary analysis.

    LENUS (Irish Health Repository)

    Ford, Ian

    2009-01-20

    Reduced glomerular filtration rate (GFR) is associated with increased cardiovascular risk in young and middle aged individuals. Associations with cardiovascular disease and mortality in older people are less clearly established. We aimed to determine the predictive value of the GFR for mortality and morbidity using data from the 5,804 participants randomized in the Prospective Study of Pravastatin in the Elderly at Risk (PROSPER).

  12. Estimation in adults of the glomerular filtration rate in [99mTc] DTPA renography - the rate constant method

    International Nuclear Information System (INIS)

    Carlsen, Ove

    2004-01-01

    The purpose of this study was to design an alternative and robust method for estimation of glomerular filtration rate (GFR) in [ 99 mTc]-diethylenetriaminepentaacetic acid ([ 99 mTc] -DTPA renography with a reliability not significantly lower than that of the conventional Gates' method. Methods: The method is based on renographies lasting 40 min in which regions of interest (ROIs) are manually created over selected parts of certain blood pools (e.g. heart, lungs, spleen, and liver). For each ROI the corresponding time-activity curve (TAC) was generated, decay corrected and exposed to a monoexponential fit in the time interval 10 to 40 min postinjection. The rate constant in min-1 of the monoexponential fit was denoted BETA. Following an iterative procedure comprising usually 5-10 manually created ROIs, the monoexponential fit with the maximum rate constant (BETA max ) was used for estimation of GFR. Results: In a patient material of 54 adult subjects in whom GFR was determined with multiple or one sample techniques with [ 51 Cr]-ethylenediaminetetraacetic acid ([ 51 Cr]-EDTA) the regression curve of standard GFR (GFR std ) (i.e. GFR adjusted to 1.73 m 2 body surface area) showed a close, non-linear relationship with BETA max with a correlation coefficient of 95%. The standard errors of estimate (SEE) were 6.6, 10.6 and 16.8 for GFR std equal to 30, 60, and 120 ml/(min .73 m 2 ), respectively. The corresponding SEE values for almost the same patient material using Gates' method were 8.4, 11.9, and 16.8 ml/(min 1.73 m 2 ). Conclusions: The alternative rate constant method yields estimates of GFR std with SEE values equal to or slightly smaller than in Gates' method. The two methods provide statistically uncorrelated estimates of GFR std . Therefore, pooled estimates of GFR std can be calculated with SEE values approximately 1.41 times smaller than those mentioned above. The reliabilities of the pooled estimate of GFR std separately and of the multiple samples method

  13. Enhancement of glomerular filtration rate and renal plasma flow by oral glucose load in well controlled insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Sandahl Christiansen, J; Christensen, C K; Hermansen, K

    1986-01-01

    Glomerular filtration rate (GFR) and renal plasma flow (RPF) were measured in 27 patients with uncomplicated insulin-dependent diabetes (IDDM) before and after an oral glucose load of 1.1 g glucose/kg body wt. In the 18 patients showing near-normoglycaemia (blood glucose less than or equal to 8...... mmol/l) before the glucose challenge the increase in blood glucose from 4.2 +/- 1.7 to 15.2 +/- 2.3 mmol/l was accompanied by an enhancement of GFR from 128 +/- 15 to 132 +/- 14 ml/min X 1.73 m2 (2p = 0.030) and of RPF from 534 +/- 116 to 562 +/- 105 ml/min X 1.73 m2 (2p = 0.023). By contrast oral...... glucose load to the nine patients with hyperglycaemia (greater than 8 mmol/l) during baseline conditions raising blood glucose from 11.9 +/- 2.0 to 19.6 +/- 1.5 mmol/l was accompanied by a reduction in GFR from 149 +/- 15 to 139 +/- 9 ml/min X 1.73 m2 (2p less than 0.001) while RPF was unchanged...

  14. Correlation and clinical significance between glomerular filtration rate and age in living-related kidney donors

    International Nuclear Information System (INIS)

    Zhao Xiuyi; Shao Yahui; Wang Yanming; Zhang Aimin; Hao Junwen; Tian Jun; Sun Ben; Han Jiankui

    2010-01-01

    Objective: To quantitatively investigate the effect of age on the glomerular filtration rate (GFR) in living-related kidney donors. to analyze the clinical value and the dependence of GFR on age and to provide an objective basis for the selection of the living kidney donor. Methods: One hundred and sixty-one living-related kidney donors were divided into four age groups, namely 20-29 years (n=52), 30-39 years (n=44), 40-49 years (n=38) and ≥50 years (n=27). On the other hand, the total donors were divided into the groups older than 55 years (n=24) and younger than 55 years (n=137). To quantify GFR in all the subjects using the 99 Tc m -diethylenetriamine pentaacetic acid ( 99 Tc m -DTPA) renography according to standard procedure and to evaluate the effects of age on renal function. Results: The total GFR in living-related kidney donors was calculated as (89.55±12.87) ml·min -1 ·(1.73 m 2 ) -1 . The GFR in the first to the four age groups were (88.27±12.29) ml·min -1 ·(1.73 m 2 ) -1 , (91.85±14.51) ml·min -1 ·(1.73 m 2 ) -1 , (98.25±11.26) ml·min -1 ·(1.73 m 2 ) -1 and (88.24±13.20) ml·min -1 ·(1.73 m 2 ) -1 . The difference of GFR were not significant between the four age groups (F=2.09, P=0.10). The GFR in the donors older than 55 years and younger than 55 years were (88.57±13.14) ml·min -1 ·(1.73 m 2 ) -1 and (89.44±10.34) ml·min -1 ·(1.73 m 2 ) -1 , there no significant difference in GFR between the two groups (F=1.31, P=0.25). When relating GFR to age in all the living-related kidney donors, there was no significant correlation (r=-0.033, P=0.69). No serious complications occurred after living kidney transplantation, serum creatinine values and blood urea nitrogen recovered to the normal levels in a short period, hepatic and renal functions were normal. Conclusion: This study indicated that the GFR values were not correlated with the change of age in living-related kidney donors, and the results were helpful for the selection of living

  15. Effect of benazepril, robenacoxib and their combination on glomerular filtration rate in cats.

    Science.gov (United States)

    King, Jonathan N; Panteri, Alessandro; Graille, Melanie; Seewald, Wolfgang; Friton, Gabriele; Desevaux, Cyril

    2016-06-23

    Combined use of angiotensin-converting enzyme inhibitors and nonsteroidal anti-inflammatory drugs may induce acute kidney injury in humans, especially when combined with diuretics. The objective of this investigation was to evaluate the effects of benazepril, robenacoxib and their combination in healthy cats. In each of two studies (study 1 followed by study 2), 32 healthy cats were randomised to one of four groups (n = 4 male and 4 female cats per group) in a parallel-group design. The groups received orally once daily for 7 days either placebo (control group), benazepril, robenacoxib or benazepril plus robenacoxib. In study 2, all groups received in addition 0.5 mg/kg furosemide twice daily by subcutaneous injection for 7 days. Benazepril, robenacoxib and their combination were well tolerated as evidenced from lack of clinical signs and no negative effects on body weight, feed consumption and clinical chemistry, haematology and urinalysis variables. The primary endpoint of the study was the glomerular filtration rate (GFR), which was estimated from the plasma clearance of iohexol. In the absence of furosemide, GFR was significantly higher in cats receiving the combination of benazepril plus robenacoxib compared to the other three groups, and was also significantly higher in females receiving only benazepril compared to the control. Administration of furosemide induced diuresis, reduced GFR and activated the renin-aldosterone-angiotensin system, evidenced from increased plasma renin activity and plasma aldosterone concentrations. Compared to the control group in cats treated with furosemide, GFR was increased by benazepril (females only) but decreased by robenacoxib (males only). Benazepril, robenacoxib and their combination significantly inhibited the increase in plasma aldosterone induced by furosemide. The combination of benazepril and robenacoxib was well tolerated and either increased or had a neutral effect on GFR in healthy cats without or with

  16. Dispersion and Filtration of Carbon Nanotubes (CNTs) and Measurement of Nanoparticle Agglomerates in Diesel Exhaust.

    Science.gov (United States)

    Wang, Jing; Pui, David Y H

    2013-01-14

    Carbon nanotubes (CNTs) tend to form bundles due to their geometry and van der Walls forces, which usually complicates studies of the CNT properties. Dispersion plays a significant role in CNT studies and we summarize dispersion techniques to generate airborne CNTs from suspensions or powders. We describe in detail our technique of CNT aerosolization with controlled degree of agglomeration using an electrospray system. The results of animal inhalation studies using the electrosprayed CNTs are presented. We have performed filtration experiments for CNTs through a screen filter. A numerical model has been established to simulate the CNT filtration experiments. Both the modeling and experimental results show that the CNT penetration is less than the penetration for a sphere with the same mobility diameter, which is mainly due to the larger interception length of the CNTs. There is a need for instruments capable of fast and online measurement of gas-borne nanoparticle agglomerates. We developed an instrument Universal NanoParticle Analyzer (UNPA) and the measurement results for diesel exhaust particulates are presented. The results presented here are pertinent to non-spherical aerosol particles, and illustrate the effects of particle morphology on aerosol behaviors.

  17. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  18. Functional evaluation of hydronephrosis by diffusion-weighted MR imaging: Relationship between apparent diffusion coefficient and split glomerular filtration rate

    International Nuclear Information System (INIS)

    Toyoshima, S.; Noguchi, K.; Seto, H.; Shimizu, M.; Watanabe, N.

    2000-01-01

    To determine the relationship between apparent diffusion coefficient (ADC) values measured by diffusion-weighted MR imaging and split renal function determined by renal scintigraphy in patients with hydronephrosis. Material and Methods: Diffusion-weighted imaging on a 1.5 T MR unit and renal scintigraphy were performed in 36 patients with hydronephrosis (45 hydronephrotic kidneys, 21 non-hydronephrotic kidneys). ADC values of the individual kidneys were measured by diffusion-weighted MR imaging. Split renal function (glomerular filtration rate (GFR)) was determined by renal scintigraphy using 99m Tc-DTPA. The relationship between ADC values and split GFR was examined in 66 kidneys. The hydronephrotic kidneys were further classified into three groups (severe renal dysfunction, GFR 25 ml/min, n=28), and mean values for ADCs were calculated. Results: In hydronephrotic kidneys, there was a moderate positive correlation between ADC values and split GFR (R2=0.56). On the other hand, in non-hydronephrotic kidneys, poor correlation between ADC values and split GFR was observed (R2=0.08). The mean values for ADCs of the dysfunctioning hydronephrotic kidneys (severe renal dysfunction, 1.32x10 -3 ±0.18x10 -3 mm 2 /s; moderate renal dysfunction, 1.38x10 -3 ±0.10x10 -3 mm2/s) were significantly lower than that of the normal functioning hydronephrotic kidneys (1.63x10 -3 ±0.12±10 -3 mm 2 /s). Conclusion: These results indicated that measurement of ADC values by diffusion-weighted MR imaging has a potential value in the evaluation of the functional status of hydronephrotic kidneys

  19. Optical measurement of isolated canine lung filtration coefficients at normal hematocrits.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Finney, C; Roselli, R J

    1997-12-01

    In this study, lung filtration coefficient (Kfc) values were measured in eight isolated canine lung preparations at normal hematocrit values using three methods: gravimetric, blood-corrected gravimetric, and optical. The lungs were kept in zone 3 conditions and subjected to an average venous pressure increase of 10.24 +/- 0.27 (SE) cmH2O. The resulting Kfc (ml . min-1 . cmH2O-1 . 100 g dry lung wt-1) measured with the gravimetric technique was 0.420 +/- 0.017, which was statistically different from the Kfc measured by the blood-corrected gravimetric method (0.273 +/- 0.018) or the product of the reflection coefficient (sigmaf) and Kfc measured optically (0. 272 +/- 0.018). The optical method involved the use of a Cellco filter cartridge to separate red blood cells from plasma, which allowed measurement of the concentration of the tracer in plasma at normal hematocrits (34 +/- 1.5). The permeability-surface area product was measured using radioactive multiple indicator-dilution methods before, during, and after venous pressure elevations. Results showed that the surface area of the lung did not change significantly during the measurement of Kfc. These studies suggest that sigmafKfc can be measured optically at normal hematocrits, that this measurement is not influenced by blood volume changes that occur during the measurement, and that the optical sigmafKfc agrees with the Kfc obtained via the blood-corrected gravimetric method.

  20. Optical measurement of isolated canine lung filtration coefficients after alloxan infusion.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Finney, C; Roselli, R J

    1998-04-01

    In this study, lung filtration coefficient (Kfc) was measured in eight isolated canine lung preparations by using three methods: standard gravimetric (Std), blood-corrected gravimetric (BC), and optical. The lungs were held in zone III conditions and were subjected to an average venous pressure increase of 8.79 +/- 0.93 (mean +/- SD) cmH2O. The permeability of the lungs was increased with an infusion of alloxan (75 mg/kg). The resulting Kfc values (in milliliters . min-1 . cmH2O-1 . 100 g dry lung weight-1) measured by using Std and BC gravimetric techniques before vs. after alloxan infusion were statistically different: Std, 0.527 +/- 0.290 vs. 1. 966 +/- 0.283; BC, 0.313 +/- 0.290 vs. 1.384 +/- 0.290. However, the optical technique did not show any statistical difference between pre- and postinjury with alloxan, 0.280 +/- 0.305 vs. 0.483 +/- 0. 297, respectively. The alloxan injury, quantified by using multiple-indicator techniques, showed an increase in permeability and a corresponding decrease in reflection coefficient for albumin (sigmaf). Because the optical method measures the product of Kfc and sigmaf, this study shows that albumin should not be used as an intravascular optical filtration marker when permeability is elevated. However, the optical technique, along with another means of measuring Kfc (such as BC), can be used to calculate the sigmaf of a tracer (in this study, sigmaf of 0.894 at baseline and 0.348 after injury). Another important finding of this study was that the ratio of baseline-to-injury Kfc values was not statistically different for Std and BC techniques, indicating that the percent contribution of slow blood-volume increases does not change because of injury.

  1. Detection of Chronic Kidney Disease by Using Different Equations of Glomerular Filtration Rate in Patients with Type 2 Diabetes Mellitus: A Cross-Sectional Analysis

    OpenAIRE

    Zaman, Sojib Bin

    2017-01-01

    Introduction Chronic kidney disease (CKD) is a global threat due to its high mortality. It is essential to know the actual magnitude of diabetic CKD to design a specific management program. However, there is limited knowledge regarding the most suitable equation to measure CKD in patients with Type 2 diabetes mellitus (T2DM). This paper aimed to analyze estimated glomerular filtration rate (eGFR) based on different equations to detect the CKD among T2DM.? Methods A hospital-based cross-sectio...

  2. Serum Adiponectin and Glomerular Filtration Rate in Patients with Type 2 Diabetes.

    Directory of Open Access Journals (Sweden)

    Lorena Ortega Moreno

    Full Text Available High serum adiponectin has been increased in several conditions of kidney disease. Only sparse and conflicting results have been reported in patients with type 2 diabetes (T2D, a subgroup of individuals who are at high risk for renal dysfunction. The aim of this study was to fill up this gap of knowledge by investigating such association in a large sample of Italian diabetic patients. The association between serum adiponectin levels and estimated glomerular filtration rate (eGFR by Chronic Kidney Disease-Epidemiology Collaboration CKD-EPI equation was investigated in 1,243 patients with T2D from two cross-sectional Italian studies: 878 from San Giovanni Rotondo (SGR and 365 from Foggia (FG. Serum adiponectin was inversely associated with eGFR in SGR [β (standard error, SE for 1 standard deviation (SD of adiponectin = -3.26 (0.64] and in FG [β(SE=-5.70(1.28] sample, as well as in the two studies combined [β(SE=-3.99(0.59];(p<0.0001 for all. In this combined analysis, the association was still significant after adjusting for sex, smoking habits, body mass index (BMI, waist circumference, diabetes duration, glycated hemoglobin (HbA1c, albumin creatinine ratio (ACR and anti-hyperglycemic, anti-hypertensive and anti-dyslipidemic treatments [β (SE= -2.19 (0.59, p = 0.0001]. A stronger association between each SD adiponectin increment and low eGFR was observed among patients with micro-/macro-albuminuria, as compared to those with normo-albuminuria [adjusted β(SE=-4.42(1.16 ml/min/1.73m2 vs. -1.50 (0.67 ml/min/1.73m2, respectively; p for adiponectin-by-albuminuric status = 0.022]. For each adiponectin SD increment, the odds of having eGFR < 60 ml/min/1.73m2 increased by 41% (odds ratio, OR = 1.41; 95% confidence interval, CI 1.21-1.64 in SGR sample, 53% (OR = 1.53; 95% CI 1.21-1.94 in FG sample, and 44% (OR = 1.44; 95%CI 1.27-1.64 in the two studies considered together (p<0.0001 for all. In the combined sample, further adjustment for the above

  3. Glomerular filtration rate by {sup 51}chomium and {sup 113m}indium labeled EDTA in horses; Taxa de filtracao glomerular pelo EDTA marcado com {sup 51}cromo e com {sup 113m}indio em equinos

    Energy Technology Data Exchange (ETDEWEB)

    Maliska, C.; D' Almeida, J.; Pellegrini, P.M.; Schimit, T.S. [Hospital Central do Exercito (HCE), Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear; Pinho, W.R. [Centro de Ensino Superior, Valenca, RJ (Brazil). Fac. de Medicina Veterinaria; Lima, J.E.T. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    2009-07-01

    The glomerular filtration rate was determined in nine healthy horses, six male and three female, aged two to 12-year-old, by means of {sup 51}Cr and {sup 113m}In labeled EDTA single injection technique. The glomerular filtration rate was calculated from the plasma disappearance curve and the volume of distribution of the radiotracer, {sup 51}Cr-EDTA or {sup 113m}In-EDTA. The result (mean +- standard deviation) was 148.80 +- 26.42 m L.min{sup -1}.100 kg. It is concluded that the measurement of glomerular filtration rate by {sup 51}Cr-EDTA or {sup 113m}In-EDTA by single injection technique eliminates the bladder catheterization, and for its simplicity, convenience, accuracy, and low dose of radiation, can be used in horses as a method of choice in clinical routine. (author)

  4. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay.

    Science.gov (United States)

    Kemperman, F A; Silberbusch, J; Slaats, E H; van Zanten, A P; Weber, J A; Krediet, R T; Arisz, L

    1999-05-01

    Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this study was to compare cimetidine-aided GFR estimations using various creatinine assays. In 30 outpatients with NIDDM GFR was measured as the urinary clearance of continuously infused [125I]iothalamate. Plasma creatinine concentration was analysed after oral cimetidine with an alkaline picrate (AP) method, with an enzymatic (PAP) assay and with HPLC. GFR estimations were calculated with the Cockcroft Gault formula (CG). AP creatinine concentrations were significantly higher than PAP or HPLC values. GFR estimations by AP (CG(AP) 66 +/- 19 ml/min/1.73 m2, mean SD) were significantly lower than GFR (89 +/- 30), whereas CG(PAP) (85 +/- 30) and CG(HPLC) (84 +/- 34 ml/min/1.73 m2) were not. Bland and Altman analysis showed a difference between CG(AP) and GFR of -22.4 +/- 17.7 ml/min/1.73 m2; this difference becomes larger when the GFR increases. The difference between CG and GFR was only -3.8 +/- 14.8 ml/min/1.73 m2 for PAP and -4.4 +/- 17.5 ml/min/1.73 m2 for HPLC, without any systematic difference. A good assessment of the GFR from plasma creatinine after cimetidine administration is possible when creatinine is measured with an enzymatic assay or with the less convenient HPLC method. The more widespread and cheaper alkaline picrate assay is not suitable for GFR-estimation.

  5. Performance of three glomerular filtration rate estimation equations in a population of sub-Saharan Africans with Type 2 diabetes.

    Science.gov (United States)

    Agoons, D D; Balti, E V; Kaze, F F; Azabji-Kenfack, M; Ashuntantang, G; Kengne, A P; Sobngwi, E; Mbanya, J C

    2016-09-01

    We evaluated the performance of the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and Cockcroft-Gault (CG) equations against creatinine clearance (CrCl) to estimate glomerular filtration rate (GFR) in 51 patients with Type 2 diabetes. The CrCl value was obtained from the average of two consecutive 24-h urine samples. Results were adjusted for body surface area using the Dubois formula. Serum creatinine was measured using the kinetic Jaffe method and was calibrated to standardized levels. Bland-Altman analysis and kappa statistic were used to examine agreement between measured and estimated GFR. Estimates of GFR from the CrCl, MDRD, CKD-EPI and CG equations were similar (overall P = 0.298), and MDRD (r = 0.58; 95% CI: 0.36-0.74), CKD-EPI (r = 0.55; 95% CI: 0.33-0.72) and CG (r = 0.61; 95% CI: 0.39-0.75) showed modest correlation with CrCl (all P fair-to-moderate agreement with CrCl (kappa: 0.38-0.51). The c-statistic for all three equations ranged between 0.75 and 0.77 with no significant difference (P = 0.639 for c-statistic comparison). The MDRD equation seems to have a modest advantage over CKD-EPI and CG in estimating GFR and detecting impaired renal function in sub-Saharan African patients with Type 2 diabetes. The overall relatively modest correlation with CrCl, however, suggests the need for context-specific estimators of GFR or context adaptation of existing estimators. © 2015 Diabetes UK.

  6. Measure of pore size in micro filtration polymeric membrane using ultrasonic technique and artificial neural networks

    International Nuclear Information System (INIS)

    Lucas, Carla de Souza

    2009-01-01

    This work presents a study of the pore size in micro filtration polymeric membranes, used in the nuclear area for the filtration of radioactive liquid effluent, in the residual water treatment of the petrochemical industry, in the electronic industry for the ultrapure water production for the manufacture of conductors and laundering of microcircuits and in many other processes of separation. Diverse processes for measures of pores sizes in membranes exist, amongst these, electronic microscopy, of bubble point and mercury intrusion porosimetry, however the majority of these uses destructive techniques, of high cost or great time of analysis. The proposal of this work is to measure so great of pore being used ultrasonic technique in the time domain of the frequency and artificial neural networks. A receiving/generator of ultrasonic pulses, a immersion transducer of 25 MHz was used, a tank of immersion and microporous membranes of pores sizes of 0,2 μm, 0,4 μm, 0,6 μm, 8 μm, 10 μm and 12 μm. The ultrasonic signals after to cover the membrane, come back to the transducer (emitting/receiving) bringing information of the interaction of the signal with the membranes. These signals had been used for the training of neural networks, and these had supplied the necessary precision the distinction of the same ones. Soon after, technique with the one of electronic microscopy of sweepings was made the comparison of this. The experiment showed very resulted next to the results gotten with the MEV, what it indicated that the studied technique is ideal for measure of pore size in membranes for being not destructive and of this form to be able to be used also on-line of production. (author)

  7. Insulin's acute effects on glomerular filtration rate correlate with insulin sensitivity whereas insulin's acute effects on proximal tubular sodium reabsorption correlate with salt sensitivity in normal subjects

    NARCIS (Netherlands)

    ter Maaten, JC; Bakker, SJL; Serne, EH; ter Wee, PM; Gans, ROB

    1999-01-01

    Background. Insulin induces increasing distal tubular sodium reabsorption. Opposite effects of insulin to offset insulin-induced sodium retention are supposedly increases in glomerular filtration rate (GFR) and decreases in proximal tubular sodium reabsorption. Defects in these opposing effects

  8. Estimation of glomerular filtration rate in cancer patients with abnormal body composition and relation with carboplatin toxicity.

    Science.gov (United States)

    Bretagne, M; Jouinot, A; Durand, J P; Huillard, O; Boudou Rouquette, P; Tlemsani, C; Arrondeau, J; Sarfati, G; Goldwasser, F; Alexandre, J

    2017-07-01

    Carboplatin clearance is correlated with glomerular filtration rate (GFR) and usually estimated with creatinine clearance using Cockcroft-Gault (CG) formula. Because plasma creatinine level is highly correlated with muscle mass, we hypothesized that an abnormal body composition with a low lean body mass (LBM) percentage [(LBM/weight) × 100] may result in inadequate carboplatin dosing. Serum cystatin C is an alternative marker of GFR, not affected by muscle mass. We aimed to investigate the influence of total LBM and LBM percentage on GFR calculation, using creatinine (CrCl) or cystatin C (GFR cysC-creat ) in cancer patients. Pretreatment serum creatinine and cystatin C were prospectively measured in consecutive patients. CrCl (CG formula), GFR cysC-creat (CKD-EPI creatinine-cystatin equation), and LBM (CT scan) were calculated. Severe thrombocytopenia post-carboplatin were analyzed. In 131 patients without renal insufficiency, LBM was correlated with creatinine (r = 0.30, p LBM percentage, the CrCl was significantly higher than GFR cysC-creat indicating an overestimation of GFR with creatinine (p = 0.0004). In 24 patients treated with carboplatin AUC 5 (mg/ml min) ± paclitaxel, the risk of severe thrombocytopenia was associated with lower LBM percentage (p = 0.0002) and higher CrCl/GFR cysC-creat ratio (p = 0.006). By ROC analysis, the CrCl/GFR cysC-creat ratio threshold predicting severe thrombocytopenia was 1.23. A low LBM percentage increases the risk of inadequate GFR calculation by CG formula, and carboplatin overdosage with severe thrombocytopenia. High CrCl/GFR cysC-creat ratio allows the identification of these patients.

  9. Impact of estimated glomerular filtration rate based on plasma cystatin C and serum creatinine levels before allogeneic hematopoietic cell transplantation.

    Science.gov (United States)

    Wada, Hidenori; Kanda, Junya; Akahoshi, Yu; Nakano, Hirofumi; Ugai, Tomotaka; Yamasaki, Ryoko; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Ashizawa, Masahiro; Sato, Miki; Terasako-Saito, Kiriko; Kimura, Shun-Ichi; Kikuchi, Misato; Nakasone, Hideki; Yamazaki, Rie; Kako, Shinichi; Tanihara, Aki; Nishida, Junji; Kanda, Yoshinobu

    2018-06-01

    No standard method for measuring renal function has been established in allogeneic hematopoietic cell transplantation (allo-HCT). We retrospectively analyzed 80 patients with hematological diseases who underwent allo-HCT at our center. We assessed renal function using creatinine clearance (Ccr), estimated glomerular filtration rate (eGFR) based on creatinine (eGFRcre), eGFR based on cystatin C (eGFRcys), and the average of eGFRcre and eGFRcys (eGFRave). We then evaluated the impact of pre-transplant renal function on the exacerbation of renal function and non-relapse mortality after transplantation. There was a significant correlation between Ccr and eGFRcre, eGFRcys, and eGFRave. eGFRave best predicted the exacerbation of renal function according to the area under the receiver-operating characteristic curve. The cumulative incidence of renal function exacerbation at 1 year was higher in the lower eGFRave group (<90 ml/min/1.73 m 2 ) than in the higher eGFRave group (≥90 ml/min/1.73 m 2 ; 0.85 vs. 0.39, p < 0.001), which was confirmed by a multivariate analysis (HR 2.75, p = 0.001). A lower eGFRave value was a marginally significant factor for non-relapse mortality (HR 3.29, p = 0.076). Among the four parameters, eGFRave best predicted the exacerbation of renal function in allo-HCT. Further, the marginal association between low eGFRave and high non-relapse mortality warrants further study in a prospective study in allo-HCT.

  10. Verification on the use of the Inoue method for precisely determining glomerular filtration rate in Philippine pediatrics

    Science.gov (United States)

    Magcase, M. J. D. J.; Duyan, A. Q.; Carpio, J.; Carbonell, C. A.; Trono, J. D.

    2015-06-01

    The objective of this study is to validate the Inoue method so that it would be the preferential choice in determining glomerular filtration rate (GFR) in Philippine pediatrics. The study consisted of 36 patients ranging from ages 2 months to 19 years old. The subjects used were those who were previously subjected to in-vitro method. The scintigrams of the invitro method was obtained and processed for split percentage uptake and for parameters needed to obtain Inoue GFR. The result of this paper correlates the Inoue GFR and In-vitro method (r = 0.926). Thus, Inoue method is a viable, simple, and practical technique in determining GFR in pediatric patients.

  11. Effect of Vitamin D Receptor Activators on Glomerular Filtration Rate: A Meta-Analysis and Systematic Review.

    Directory of Open Access Journals (Sweden)

    Qian Zhang

    Full Text Available Vitamin D receptor activators (VDRAs can protect against mineral bone disease, but they are reported to elevate serum creatinine (SCr and may also reduce glomerular filtration rate (GFR.We conducted a systematic review and meta-analysis of randomized clinical trials (RCTs to evaluate the effect of VDRAs on kidney function and adverse events. MEDLINE, EMBASE, the Cochrane Controlled Trials Register were searched for RCTs that evaluate vitamin D receptor activators (alfacalcidol, calcitriol, doxercalciferol, falecalcitriol, maxacalcitol and paricalcitol up to March 2015.We included 31 studies, all of which were performed between 1976 and 2015, which enrolled 2621 patients. Patients receiving VDRAs had lower eGFR (weighted mean difference WMD -1.29 mL/min /1.73 m2, 95% CI -2.42 to -0.17 and elevated serum creatinine (WMD 7.03 μmol/L, 95% CI 0.61 to 13.46 in sensitivity analysis excluding studies with dropout rate more than 30%. Subgroup analysis of the 5 studies that not use SCr-based measures did not indicated lower GFR in the VDRAs group(WMD -0.97 mL/min/1.73 m2, 95% CI -4.85 to 2.92. Compared with control groups, there was no difference in all-cause mortality (relative risk RR 1.41, 95% CI 0.58 to 3.80, cardiovascular disease (RR 0.84, 95% CI 0.42 to 1.71, and severe adverse events (RR 1.15, 95% CI 0.75 to 1.77 for the VDRAs groups. Episodes of hypercalcemia (RR 3.29, 95% CI 2.02 to 5.38 were more common in the VDRAs group than in the control group.Administration of VDRAs increased serum creatinine levels. Subgroup analysis of studies that did not use SCr-based measures did not indicate a lower GFR in the VDRA group. Future studies with non-SCr-based measures are needed to assess whether the mild elevations of serum creatinine are of clinical significance.

  12. Measurement of single-kidney glomerular filtration function from magnetic resonance perfusion renography

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Meiying; Cheng, Yingsheng [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Shanghai 200233 (China); Zhao, Binghui, E-mail: binghuizhao@163.com [Department of Radiology, Shanghai Tenth People' s Hospital, Tongji University, Shanghai 200072 (China)

    2015-08-15

    Highlights: • MRPR monitors the transit of contrast material through nephron. • MRPR could reveal renal physiological characteristics in quality and quantity. • This review outlines the basics and future challenges of DCE MRPR. - Abstract: Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, they’re all not a good standard to evaluate the early damage of renal function. In recent years, the improvement of MRI hardware and software makes it possible to reveal physiological characteristics such as renal blood flow or GFR by dynamic contrast enhancement magnetic resonance perfusion renography (DEC MRPR). MRPR is a method used to monitor the transit of contrast material, typically a gadolinium chelate, through the renal cortex, the medulla, and the collecting system. This review outlines the basics of DCE MRPR included acquisition of dynamic MR perfusion imaging, calculation of the contrast concentration from signal intensity and compartment models, and some challenges of MRPR method faced in prospective clinical application.

  13. Age- and sex-specific reference limits for creatinine, cystatin C and the estimated glomerular filtration rate.

    Science.gov (United States)

    Hannemann, Anke; Friedrich, Nele; Dittmann, Kathleen; Spielhagen, Christin; Wallaschofski, Henri; Völzke, Henry; Rettig, Rainer; Endlich, Karlhans; Lendeckel, Uwe; Stracke, Sylvia; Nauck, Matthias

    2011-11-14

    Early detection of patients with chronic kidney disease is of great importance. This study developed reference limits for serum creatinine and serum cystatin C concentrations and for the estimated glomerular filtration rate (eGFR) in healthy subjects from the general population aged 25-65 years. This study defined a reference population including 985 subjects from the first follow-up of the Study of Health in Pomerania. Serum creatinine was measured with a modified kinetic Jaffé method. Serum cystatin C was measured with a nephelometric assay. The eGFR was calculated from serum creatinine according to the Cockcroft-Gault (eGFR(CG)) and the Modification of Diet in Renal Disease (eGFR(MDRD)) equation, respectively, as well as from serum cystatin C according to the formula by Larsson (eGFR(Larsson)). Non-parametric quantile regression was used to estimate the reference limits. For serum creatinine and serum cystatin C the 95th percentile and for eGFR(CG), eGFR(MDRD) and eGFR(Larsson) the 5th percentile were selected as reference limits. All data was weighted to reflect the age- and sex-structure of the German population in 2008. The reference limits for serum creatinine (men: 1.11-1.23 mg/dL; women: 0.93-1.00 mg/dL) and serum cystatin C levels (men: 0.92-1.04 mg/L; women: 0.84-1.02 mg/L) increased with advancing age. The reference limits for eGFR decreased with increasing age (eGFR(CG) men: 106.0-64.7 mL/min, women 84.4-57.9 mL/min; eGFR(MDRD) men: 82.5-62.2 mL/min/1.73 m², women 75.0-58.2 mL/min/1.73 m²; eGFR(Larsson) men: 85.5-72.9 mL/min, women 94.5-75.7 mL/min). This study presents age- and sex-specific reference limits for five measures of renal function based on quantile regression models.

  14. Glomerular Filtration Rate Estimation in Renal and Non-Renal Solid Organ Transplantation

    DEFF Research Database (Denmark)

    Hornum, Mads; Feldt-Rasmussen, Bo

    2017-01-01

    Following transplantation (TX) of both renal and non-renal organs, a large proportion of patients have renal dysfunction. There are multiple causes for this. Chronic nephrotoxicity and high doses of calcineurin inhibitors are important factors. Preoperative and perioperative factors like hyperten......Following transplantation (TX) of both renal and non-renal organs, a large proportion of patients have renal dysfunction. There are multiple causes for this. Chronic nephrotoxicity and high doses of calcineurin inhibitors are important factors. Preoperative and perioperative factors like...... hypertension, hypotension, drugs and infections may play a causative role as well. Organ-specific causes include hepatorenal syndrome, cirrhosis, low cardiac function, low respiratory function and diabetes developed both before and after TX. It is important to be able to perform precise and valid measurements...... rate methods for use in renal and non-renal TX....

  15. Cumulative and current exposure to potentially nephrotoxic antiretrovirals and development of chronic kidney disease in HIV-positive individuals with a normal baseline estimated glomerular filtration rate

    DEFF Research Database (Denmark)

    Mocroft, Amanda; Lundgren, Jens D; Ross, Michael

    2016-01-01

    BACKGROUND: Whether or not the association between some antiretrovirals used in HIV infection and chronic kidney disease is cumulative is a controversial topic, especially in patients with initially normal renal function. In this study, we aimed to investigate the association between duration...... of exposure to antiretrovirals and the development of chronic kidney disease in people with initially normal renal function, as measured by estimated glomerular filtration rate (eGFR). METHODS: In this prospective international cohort study, HIV-positive adult participants (aged ≥16 years) from the D......:A:D study (based in Europe, the USA, and Australia) with first eGFR greater than 90 mL/min per 1·73 m(2) were followed from baseline (first eGFR measurement after Jan 1, 2004) until the occurrence of one of the following: chronic kidney disease; last eGFR measurement; Feb 1, 2014; or final visit plus 6...

  16. Comparison between a serum creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

    Science.gov (United States)

    Karimzadeh, Iman; Khalili, Hossein

    2016-06-06

    Serum cystatin C (Cys C) has a number of advantages over serum creatinine in the evaluation of kidney function. Apart from Cys C level itself, several formulas have also been introduced in different clinical settings for the estimation of glomerular filtration rate (GFR) based upon serum Cys C level. The aim of the present study was to compare a serum Cys C-based equation with Cockcroft-Gault serum creatinine-based formula, both used in the calculation of GFR, in patients receiving amphotericin B. Fifty four adult patients with no history of acute or chronic kidney injury having been planned to receive conventional amphotericin B for an anticipated duration of at least 1 week for any indication were recruited. At three time points during amphotericin B treatment, including days 0, 7, and 14, serum cystatin C as well as creatinine levels were measured. GFR at the above time points was estimated by both creatinine (Cockcroft-Gault) and serum Cys C based equations. There was significant correlation between creatinine-based and Cys C-based GFR values at days 0 (R = 0.606, P = 0.001) and 7 (R = 0.714, P creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

  17. Measurement of water filtration in skeletal muscle in man by an osmotic transient method

    DEFF Research Database (Denmark)

    Palm, T; Nielsen, S L; Lassen, N A

    1983-01-01

    Water filtration in the human forearm was determined with a new method using a hyperoncotic transient of albumin solution infused into the brachial artery. Baseline dilution of labelled albumin in deep forearm vein plasma in excess of the contribution from arterial blood and from infusate...... was assumed to originate from extravascular water filtered into the blood by the transient. The filtration coefficient (Fc) was determined as the ratio between filtered water and increase in colloid osmotic pressure in the blood samples, and gives the filtrative water permeability in the exchange areas...... muscles, but it is of the same order of magnitude as the capillary filtration coefficient (CFC) determined plethysmographically for the entire forearm by the venous stasis technique....

  18. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    Science.gov (United States)

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient

  19. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  20. Normal values of glomerular filtration rate in geriatrics in Bandung and its correlation with serum cystatin-C levels

    International Nuclear Information System (INIS)

    Resnaldi, A.; Yuliani, A.; Hidayat, B.; Kartamihardja, A.H.S.

    2007-01-01

    Full text: Determination of the normal values of glomerular filtration rate (GFR) is an essential part of the evaluation of patient with kidney disease. GFR almost linearly decreases with age at a mean annual rate of 0.8 ml/min/1.73 m2 over the age of 30 years old. According to NHANES III mean GFR for population with age > 60 years was 80 mL/min/1.73 m2. It is recommended for each centre to determine their own normal values of GFR for different age groups particularly in geriatric population. Recently, serum cystatin-C has been proposed as a new endogenous marker of glomerular filtration rate. Aim of the study was to determination of normal values of glomerular filtration rate (GFR) in geriatrics in Bandung and its correlation with serum Cystatin-C levels. Subjects were 24 males and 36 females (mean age 66.71 ± 6.7 years; range 60-87 yrs), without any renal and/or systemic disease. Creatinine clearance was estimated by using Cockroft-Gault formula and serum cystatin-C level were determined by using particle enhanced immunonephelometric method, while GFR values were determined by external body counting methods using Tc-99m DTPA ( Gates' methods ). Pearson correlation was used to determine correlation between variables and a P value < 0.05 is considered significant. Results and Discussion. Mean total GFR was 67.57 ml/min/1.73 m2 (SD ± 16.02), range from 45 to 100 ml/min/1.73 m2. Mean total GFR for male was 69.46 ml/min/1.73 m2, and female was 66.31 ml/min/1.73 m2, the difference was statistically significant (p < 0.05). The results were lower than NHANES III values. There was a better correlation between total GFR and cystatin-C level (r = -0.522 and p < 0.001) compared to total GFR and creatinine clearance (r 0.306 and p < 0.005). Mean creatinine clearance was 57.93 ml/min and serum cystatin-C was 0.97 mg/dl, the correlation was statistically significant (r -0.414 and p < 0.005). Conclusions: The normal values of GFR in geriatric population in Bandung were 69

  1. Study of the post-equilibrium slope approximation in the calculation of glomerular filtration rate using the 51Cr-EDTA single injection technique

    International Nuclear Information System (INIS)

    Nimmon, C.C.; McAlister, J.M.; Hickson, B.; Cattell, W.R.

    1975-01-01

    A comparison of methods for calculating the renal clearance of EDTA from the plasma disappearance curve, after a single injection, has been made. Measurements were made on 38 patients, using external monitoring and venous blood sampling techniques, over a period of 24 h after an injection of 100 μCi of 51 Cr-EDTA. The results indicate that the period 3 - 6 h after injection is suitable for sampling the post-equilibrium part of the plasma disappearance curve for values of the glomerular filtration rate (GFR) in the range 0 - 140 ml/min. It was also found that, to within the individual measurement errors, the values of the clearance calculated by using the post-equilibrium period only (PES clearance) can be considered to show a constant proportionality to the values calculated by using the entire plasma disappearance curve (total clearance). (author)

  2. Comparison of three empirical formulae for calculating the glomerular filtration rate of patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Xiao-mei LUO

    2011-07-01

    Full Text Available Objective To compare the values of 3 empirical formulae,namely Modification of Diet in Renal Disease(MDRD study equation,Chronic Kidney Disease Epidemiology Collaboration(CKD-EPI equation,and cystatin C(Cys C single variable equations(eGFR-Cys,on predicting the glomerular filtration rate(GFR of patients with chronic kidney disease.Methods Ninety three patients with chronic kidney disease were enrolled in present study.The plasma clearance of 99mTc-diethylenetriamine pentaacetic acid(DTPA was measured the golden standard of GFR(rGFR,and estimated GFR(eGFR was calculated with the MDRD equation,CKD-EPI equation and eGFR-Cys equation,respectively.The result of rGFR with that of various eGFR was compared.Results Compared with rGFR,the mean bias of eGFR in CKD-EPI equation,eGFR-Cys equation and MDRD study equation were-3.4±10.7ml/(min·1.73m2,-4.8±11.9ml/(min·1.73m2 and-5.4±10.4ml/(min·1.73m2,respectively,and no significant difference was noted among the 3 values.The 30% accuracy of 3 equations was 74.2%,72.0% and 64.5%,respectively,no significant difference was found among the 3 values.The 30% accuracy of CKD-EPI equation was higher than that of MDRD study equation(75.7%±5.1% vs 54.1%±7.7%,P 60ml/(min·1.73m2.With 60ml/(min·1.73m2 as the diagnostic cut-off point of GFR damage,the area under receiver operating characteristic(ROC curve was 0.862 in MDRD study equation,0.863 in CKD-EPI equation and 0.877 in eGFR-Cys equation,respectively,and no significant difference was found among the 3 values.Conclusions There are no significant differences among the 3 equations in predicting the GFR of patients with CKD.However,further studies are needed to investigate whether MDRD study equation could be replaced by the CKD-EPI equation and eGFR-Cys equation.

  3. Estimated Glomerular Filtration Rate, Cardiovascular Events and Mortality Across Age Groups Among Individuals Older Than 60 Years in Southern Europe.

    Science.gov (United States)

    Salvador-González, Betlem; Gil-Terrón, Neus; Cerain-Herrero, M Jesús; Subirana, Isaac; Güell-Miró, Roser; Rodríguez-Latre, Luisa M; Cunillera-Puértolas, Oriol; Elosua, Roberto; Grau, Maria; Vila, Joan; Pascual-Benito, Luisa; Mestre-Ferrer, Jordi; Ramos, Rafel; Baena-Díez, José Miguel; Soler-Vila, Maria; Alonso-Bes, Eva; Ruipérez-Guijarro, Laura; Álvarez-Funes, Virtudes; Freixes-Villaró, Esther; Rodríguez-Pascual, Mercedes; Martínez-Castelao, Alberto

    2018-06-01

    Individuals with a decreased estimated glomerular filtration rate (eGFR) are at increased risk of all-cause (ACM) and cardiovascular mortality; there is ongoing debate about whether older individuals with eGFR 45 to 59mL/min/1.73 m 2 are also at increased risk. We evaluated the association between eGFR and ACM and cardiovascular events (CVE) in people aged 60 to 74 and ≥ 75 years in a population with a low coronary disease incidence. We conducted a retrospective cohort study by using primary care and hospital electronic records. We included 130 233 individuals aged ≥ 60 years with creatinine measurement between January 1, 2010 and December 31, 2011; eGFR was estimated by using the Chronic Kidney Disease Epidemiology Collaboration creatinine equation. The independent association between eGFR and the risk of ACM and hospital admission due to CVE were determined with Cox and Fine-Gray regressions, respectively. The median was age 70 years, and 56.1% were women; 13.5% had eGFR < 60 (69.7% eGFR 45-59). During a median follow-up of 38.2 months, 6474 participants died and 3746 had a CVE. For ACM and CVE, the HR in older individuals became significant at eGFR < 60. Fully adjusted HR for ACM in the eGFR 45 to 59 category were 1.61; 95%CI, 1.37-1.89 and 1.19; 95%CI, 1.10-1.28 in 60- to 74-year-olds and ≥ 75-year-olds, respectively; for CVE HR were 1.28; 95%CI, 1.08-1.51 and 1.12; 95%CI, 0.99-1.26. In a region with low coronary disease incidence, the risk of death and CVE increased with decreasing eGFR. In ≥ 75-year-olds, the eGFR 45 to 59 category, which had borderline risk for CVE, included many individuals without significant additional risk. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Predicting timing of clinical outcomes in patients with chronic kidney disease and severely decreased glomerular filtration rate.

    Science.gov (United States)

    Grams, Morgan E; Sang, Yingying; Ballew, Shoshana H; Carrero, Juan Jesus; Djurdjev, Ognjenka; Heerspink, Hiddo J L; Ho, Kevin; Ito, Sadayoshi; Marks, Angharad; Naimark, David; Nash, Danielle M; Navaneethan, Sankar D; Sarnak, Mark; Stengel, Benedicte; Visseren, Frank L J; Wang, Angela Yee-Moon; Köttgen, Anna; Levey, Andrew S; Woodward, Mark; Eckardt, Kai-Uwe; Hemmelgarn, Brenda; Coresh, Josef

    2018-03-24

    Patients with chronic kidney disease and severely decreased glomerular filtration rate (GFR) are at high risk for kidney failure, cardiovascular disease (CVD) and death. Accurate estimates of risk and timing of these clinical outcomes could guide patient counseling and therapy. Therefore, we developed models using data of 264,296 individuals in 30 countries participating in the international Chronic Kidney Disease Prognosis Consortium with estimated GFR (eGFR)s under 30 ml/min/1.73m 2 . Median participant eGFR and urine albumin-to-creatinine ratio were 24 ml/min/1.73m 2 and 168 mg/g, respectively. Using competing-risk regression, random-effect meta-analysis, and Markov processes with Monte Carlo simulations, we developed two- and four-year models of the probability and timing of kidney failure requiring kidney replacement therapy (KRT), a non-fatal CVD event, and death according to age, sex, race, eGFR, albumin-to-creatinine ratio, systolic blood pressure, smoking status, diabetes mellitus, and history of CVD. Hypothetically applied to a 60-year-old white male with a history of CVD, a systolic blood pressure of 140 mmHg, an eGFR of 25 ml/min/1.73m 2 and a urine albumin-to-creatinine ratio of 1000 mg/g, the four-year model predicted a 17% chance of survival after KRT, a 17% chance of survival after a CVD event, a 4% chance of survival after both, and a 28% chance of death (9% as a first event, and 19% after another CVD event or KRT). Risk predictions for KRT showed good overall agreement with the published kidney failure risk equation, and both models were well calibrated with observed risk. Thus, commonly-measured clinical characteristics can predict the timing and occurrence of clinical outcomes in patients with severely decreased GFR. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  5. Impact of two particle measurement techniques on the determination of N95 class respirator filtration performance against ultrafine particles

    International Nuclear Information System (INIS)

    Mostofi, Reza; Noël, Alexandra; Haghighat, Fariborz; Bahloul, Ali; Lara, Jaime; Cloutier, Yves

    2012-01-01

    Highlights: ► Performance evaluation of respirator using two different measurement techniques. ► Impaction and electrical mobility were used to characterize ultrafine particle. ► The experiment was done using ultrafine-sized poly-dispersed aerosols. ► Both techniques show that MPPS would occur at a similar size range. - Abstract: The purpose of this experimental study was to compare two different particle measurement devices; an Electrical Low Pressure Impactor (ELPI) and a Scanning Mobility Particle Sizer (SMPS), to measure the number concentration and the size distribution of NaCl salt aerosols to determine the collection efficiency of filtering respirators against poly disperse aerosols. Tests were performed on NIOSH approved N95 filtering face-piece respirators (FFR), sealed on a manikin head. Ultrafine particles found in the aerosols were also collected and observed by transmission electron microscopy (TEM). According to the results, there is a systematic difference for the particle size distribution measured by the SMPS and the ELPI. It is largely attributed to the difference in the measurement techniques. However, in spite of these discrepancies, reasonably similar trends were found for the number concentration with both measuring instruments. The particle penetration, calculated based on mobility and aerodynamic diameters, never exceeded 5% for any size range measured at constant flow rate of 85 L/min. Also, the most penetrating particle size (MPPS), with the lowest filtration efficiency, would occur at a similar ultrafine size range <100 nm. With the ELPI, the MPPS was at 70 nm aerodynamic diameter, whereas it occurred at 40 nm mobility diameter with the SMPS.

  6. Aerosol filtration

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.; De Smet, M.; Trine, J.; Hertschap, M.

    1984-01-01

    This report summarizes the work on the development of fibre metallic prefilters to be placed upstream of HEPA filters for the exhaust gases of nuclear process plants. Investigations at ambient and high temperature were carried out. Measurements of the filtration performance of Bekipor porous webs and sintered mats were performed in the AFLT (aerosol filtration at low temperature) unit with a throughput of 15 m 3 /h. A parametric study on the influence of particle size, fibre diameter, number of layers and superficial velocity led to the optimum choice of the working parameters. Three selected filter types were then tested with polydisperse aerosols using a candle-type filter configuration or a flat-type filter configuration. The small-diameter candle type is not well suited for a spraying nozzles regeneration system so that only the flat-type filter was retained for high-temperature tests. A high-temperature test unit (AFHT) with a throughput of 8 to 10 m 3 /h at 400 0 C was used to test the three filter types with an aerosol generated by high-temperature calcination of a simulated nitric acid waste solution traced with 134 Cs. The regeneration of the filter by spray washing and the effect of the regeneration on the filter performance was studied for the three filter types. The porous mats have a higher dust loading capacity than the sintered web which means that their regeneration frequency can be kept lower

  7. Glomerular filtration rate and renal recovery of [14C]-allantoin in Bali and Zebu cattle of Indonesia

    International Nuclear Information System (INIS)

    Prasitkusol, P.; Chen, X.B.; Orskov, E.R.; Kyle, D.J.; Yusiati, L.M.

    2004-01-01

    The urinary recovery of [ 14 C]-allantoin injected into the blood of Bali Cattle (Bos banteng) and Zebu cattle (Bos indicus), and the glomerular filtration rate (GFR) of these animals, were determined. The cattle were fed with king grass at 95% of ad libitum intake. The recovery of [ 14 C]-allantoin in the urine was significantly higher for Bali (83 ± SE 0.94 %) than for Zebu Cattle (74 ± SE 0.79 %). There were no significant differences in GFR between Bali and Zebu cattle (302 ± SE23.8 and 285 ± SE18.7 L/d). Within each species, there was no significant effect of GFR on the [ 14 C]-allantoin recovery. It remains to be investigated whether the differences in [ 14 C]-allantoin recovery between species is affected by GFR. (author)

  8. Beneficial Effect of Conversion to Belatacept in Kidney-Transplant Patients with a Low Glomerular-Filtration Rate

    Directory of Open Access Journals (Sweden)

    Julie Belliere

    2014-01-01

    Full Text Available Belatacept has been found to be efficient at preserving good kidney function in maintenance kidney-transplant patients. Herein, we report on the use of belatacept as a rescue therapy for two kidney-transplant patients presenting with severe adverse events after treatment with calcineurin inhibitors (CNIs and mammalian target-of-rapamycin (mTOR inhibitors. Two kidney-transplant patients developed severely impaired kidney function after receiving CNIs. The use of everolimus was associated with severe angioedema. Belatacept was then successfully used to improve kidney function in both cases, even though estimated glomerular-filtration rate before conversion was <20 mL/min. These case reports show that belatacept can be used as a rescue therapy, even if kidney function is very low in kidney-transplant patients who cannot tolerate CNIs and/or mTOR inhibitors.

  9. Simultaneous Determination of Glomerular Filtration Rate with {sup 125}I-Iothalamate and Effective Renal Plasma Flow with {sup 131}I-Hippuran

    Energy Technology Data Exchange (ETDEWEB)

    Houwen, B.; Donker, A. J.M.; Woldring, M. G.; Beekhuis, H.; Zanten, A.K. van; Looye, A.; Hem, G.K. van der [Department Of Internal Medicine, Central Isotope Laboratory, University of Groningen, Groningen (Netherlands)

    1971-02-15

    The glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were measured in patients with normal and abnormal renal functions. {sup 125}I-iothalamate and inulin were used for the estimation of the GFR; {sup 131}I-Hippuran, p-aminohippuric acid and p-acetylaminohippuric acid were used for the ERPF determination. Procedure involved the continuous infusion of a solution containing {sup 125}I-iothalamate, {sup 131}I-Hippuran, inulin and PAH or PACAH, intravenously administered by an infusion pump. The clearances were determined in two ways: (1) By means of the standard technique, i.e. the equation, (urine concentration x urine volume)/plasma concentration: (2) By using the equation, intravenous dose per minute/plasma concentration. Comparisons between the methods are made. (author)

  10. Variability of filtration and food assimilation rates, respiratory activity and multixenobiotic resistance (MXR mechanism in the mussel Perna perna under lead influence

    Directory of Open Access Journals (Sweden)

    M. L. PESSATTI

    Full Text Available The economic importance that myticulture is conquering in Santa Catarina State (South of Brazil explains the crescent search for new coastal sites for farming. Physiological and biochemical studies of the mussel Perna perna are important to the establishment of methodologies for program assessment and environmental monitoring, allowing to infer about site quality and possible influences of xenobiotic agents on coastal areas. In order to evaluate effects caused by lead poisoning (1.21 mumol.L-1, the mussels were maintained at constant temperature (25ºC and fed with Chaetoceros gracilis for 15 days. The control group was acclimatized in sea water 30‰. At the end of this period time, physiological measurements were carried out along with statistic analysis for filtration rates, lead assimilation and overall respiratory activity. The mechanism of multixenobiotic resistance (MXR was particularly evaluated in standardized gill fragments using rhodamine B accumulation and its quantification under fluorescence optical microscopy. Regarding the control group, results had shown that the mussels maintenance in a lead-poisoned environment caused higher filtration rates (1.04 and 2.3 and L.h-1.g-1; p < 0.05 and lower assimilation rates (71.96% and 54.1%, respectively. Also it was confirmed a lesser rhodamine B accumulation in the assays under influence of lead, suggesting that this metal induces the MXR mechanism expression in mussel P. perna. These results indicate that such physiological and biochemical alterations in the mussels can modify the energy fluxes of its metabolism, resulting in possible problems on the coastal systems used as cultivating sites.

  11. Variability of filtration and food assimilation rates, respiratory activity and multixenobiotic resistance (MXR mechanism in the mussel Perna perna under lead influence

    Directory of Open Access Journals (Sweden)

    PESSATTI M. L.

    2002-01-01

    Full Text Available The economic importance that myticulture is conquering in Santa Catarina State (South of Brazil explains the crescent search for new coastal sites for farming. Physiological and biochemical studies of the mussel Perna perna are important to the establishment of methodologies for program assessment and environmental monitoring, allowing to infer about site quality and possible influences of xenobiotic agents on coastal areas. In order to evaluate effects caused by lead poisoning (1.21 mumol.L-1, the mussels were maintained at constant temperature (25ºC and fed with Chaetoceros gracilis for 15 days. The control group was acclimatized in sea water 30?. At the end of this period time, physiological measurements were carried out along with statistic analysis for filtration rates, lead assimilation and overall respiratory activity. The mechanism of multixenobiotic resistance (MXR was particularly evaluated in standardized gill fragments using rhodamine B accumulation and its quantification under fluorescence optical microscopy. Regarding the control group, results had shown that the mussels maintenance in a lead-poisoned environment caused higher filtration rates (1.04 and 2.3 and L.h-1.g-1; p < 0.05 and lower assimilation rates (71.96% and 54.1%, respectively. Also it was confirmed a lesser rhodamine B accumulation in the assays under influence of lead, suggesting that this metal induces the MXR mechanism expression in mussel P. perna. These results indicate that such physiological and biochemical alterations in the mussels can modify the energy fluxes of its metabolism, resulting in possible problems on the coastal systems used as cultivating sites.

  12. Allometric equations for maximum filtration rate in blue mussels Mytilus edulis and importance of condition index

    DEFF Research Database (Denmark)

    Riisgård, Hans Ulrik; Larsen, Poul Scheel; Pleissner, Daniel

    2014-01-01

    rate (F, l h-1), W (g), and L (mm) as described by the equations: FW = aWb and FL = cLd, respectively. This is done by using available and new experimental laboratory data on M. edulis obtained by members of the same research team using different methods and controlled diets of cultivated algal cells...

  13. Association between the Delta Estimated Glomerular Filtration Rate and the Prevalence of Monoclonal Gammopathy of Undetermined Significance in Korean Males

    Directory of Open Access Journals (Sweden)

    Tae-Dong Jeong

    2014-01-01

    Full Text Available Background. We investigated the association between the reduction in the estimated glomerular filtration rate (eGFR and the prevalence of monoclonal gammopathy of undetermined significance (MGUS in Korean males. Methods. We enrolled 723 healthy Korean males. Serum creatinine concentration, serum electrophoresis, serum immunofixation, and the serum free light chain assay were performed. We calculated delta eGFR per year (ΔeGFR/yr. The prevalence of MGUS was compared based on the ΔeGFR/yr and age group. Results. Thirteen (1.8% of 723 participants exhibited the monoclonal band on serum immunofixation. Prevalence of MGUS by age group was 0.00% (0/172 for 40 years, 1.63% (6/367 for 60 years, and 3.80% (7/184 for >60 years. The median decrease in ΔeGFR/yr was 5.3%. The prevalence of MGUS in participants in their 50s with >5.3% decline in ΔeGFR/yr was significantly higher than those with 5.3% decrease in ΔeGFR/yr was similar to that of healthy males in their 60s. Conclusion. Using the rate of reduction in ΔeGFR/yr in healthy Korean males who had their serum creatinine level checked regularly may increase the MGUS detection rate in clinical practice.

  14. Association of Microalbuminuria and Estimated Glomerular Filtration Rate With Carotid Intima-Media Thickness in Patients With Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Dehdashti Shahrokh

    2015-04-01

    Full Text Available Background Atherosclerosis is the main cause of cardiovascular diseases, and its risk enhances in type 2 diabetes mellitus. Objectives This study aimed to evaluate Carotid Intima-Media Thickness (CIMT by carotid artery ultrasonography and assess its correlation with microalbuminuria and estimated Glomerular Filtration Rate (eGFR in the patients with type 2 diabetes mellitus. Patients and Methods This cross-sectional study was included 205 patients with Type 2 Diabetes Mellitus (T2DM. We recorded clinical and biochemical data such as FBS, lipid profile, and urinary albumin. Intima-media thickness of carotid arteries was measured in all patients by high frequency ultrasound. Results In simple correlation coefficients analysis, CIMT was significantly associated with total cholesterol (r = 0.197, P = 0.008, serum creatinine (r = 0.240, P = 0.001, and urinary albumin (r = 0.420, P = 0.000. Also, CIMT elevated significantly with the stage progression of chronic kidney disease (0.67 ± 0.15 mm in stage 1, 0.73 ± 0.22 mm in stage 2, and 0.82 ± 0.21 mm in stage 3 (P value = 0.024. In multivariate linear regression analysis, the duration of diabetes, weight, HDL, serum creatinine, urinary albumin, and estimated Glomerular Filtration Rate (eGFR were independently associated with CIMT (P value < 0.05 for all. Conclusions Our study shows a relationship between CIMT and renal parameters, including eGFR and albuminuria. This study confirms the importance of intensive examinations for early detection of atherosclerosis and treatment of risk factors.

  15. Prediction of cardiovascular outcome by estimated glomerular filtration rate and estimated creatinine clearance in the high-risk hypertension population of the VALUE trial.

    Science.gov (United States)

    Ruilope, Luis M; Zanchetti, Alberto; Julius, Stevo; McInnes, Gordon T; Segura, Julian; Stolt, Pelle; Hua, Tsushung A; Weber, Michael A; Jamerson, Ken

    2007-07-01

    Reduced renal function is predictive of poor cardiovascular outcomes but the predictive value of different measures of renal function is uncertain. We compared the value of estimated creatinine clearance, using the Cockcroft-Gault formula, with that of estimated glomerular filtration rate (GFR), using the Modification of Diet in Renal Disease (MDRD) formula, as predictors of cardiovascular outcome in 15 245 high-risk hypertensive participants in the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial. For the primary end-point, the three secondary end-points and for all-cause death, outcomes were compared for individuals with baseline estimated creatinine clearance and estimated GFR or = 60 ml/min using hazard ratios and 95% confidence intervals. Coronary heart disease, left ventricular hypertrophy, age, sex and treatment effects were included as covariates in the model. For each end-point considered, the risk in individuals with poor renal function at baseline was greater than in those with better renal function. Estimated creatinine clearance (Cockcroft-Gault) was significantly predictive only of all-cause death [hazard ratio = 1.223, 95% confidence interval (CI) = 1.076-1.390; P = 0.0021] whereas estimated GFR was predictive of all outcomes except stroke. Hazard ratios (95% CIs) for estimated GFR were: primary cardiac end-point, 1.497 (1.332-1.682), P cause death, 1.231 (1.098-1.380), P = 0.0004. These results indicate that estimated glomerular filtration rate calculated with the MDRD formula is more informative than estimated creatinine clearance (Cockcroft-Gault) in the prediction of cardiovascular outcomes.

  16. Factors Related to Significant Improvement of Estimated Glomerular Filtration Rates in Chronic Hepatitis B Patients Receiving Telbivudine Therapy

    Directory of Open Access Journals (Sweden)

    Te-Fu Lin

    2017-01-01

    Full Text Available Background and Aim. The improvement of estimated glomerular filtration rates (eGFRs in chronic hepatitis B (CHB patients receiving telbivudine therapy is well known. The aim of this study was to clarify the kinetics of eGFRs and to identify the significant factors related to the improvement of eGFRs in telbivudine-treated CHB patients in a real-world setting. Methods. Serial eGFRs were calculated every 3 months using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equation. The patients were classified as CKD-1, -2, or -3 according to a baseline eGFR of ≥90, 60–89, or <60 mL/min/1.73 m2, respectively. A significant improvement of eGFR was defined as a more than 10% increase from the baseline. Results. A total of 129 patients were enrolled, of whom 36% had significantly improved eGFRs. According to a multivariate analysis, diabetes mellitus (DM (p=0.028 and CKD-3 (p=0.043 were both significantly related to such improvement. The rates of significant improvement of eGFR were about 73% and 77% in patients with DM and CKD-3, respectively. Conclusions. Telbivudine is an alternative drug of choice for the treatment of hepatitis B patients for whom renal safety is a concern, especially patients with DM and CKD-3.

  17. Distribution of estimated glomerular filtration rate (eGFR) values in patients receiving contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shimoji, Keigo; Aoki, Shigeki; Nakanishi, Atsushi

    2012-01-01

    The aim of this study was to elucidate the distribution of estimated glomerular filtration rate (eGFR) values in patients who underwent gadolinium-based contrast agent (GBCA)-enhanced magnetic resonance imaging (MRI) at different types of hospitals. We retrospectively studied 2,550 patients who underwent MRI at five institutions. We recorded the date and value of each patient's eGFR test. The distribution of eGFR values was compared with that in the general Japanese population. A total of 84.3% of patients had their eGFRs evaluated before GBCA-enhanced MRI. Of these, 84.7% were evaluated within 3 months before the GBCA-enhanced MRI, and 1.3% were evaluated on the day of the GBCA-enhanced MRI. A total of 87.2% of patients tested had an eGFR of ≥60 ml/min/1.73 m 2 ; 12.8% had an eGFR of 2 , and no patients had an eGFR of 2 . The rate of renal function evaluation differed among hospitals. The prevalence of low eGFR values was greater in Juntendo Tokyo Koto Geriatric Medical Center than in the other hospitals, and the prevalence of low eGFR values was greater in patients who underwent GBCA-enhanced MRI than in the general Japanese population. (author)

  18. Decline in estimated glomerular filtration rate and subsequent risk of end-stage renal disease and mortality.

    Science.gov (United States)

    Coresh, Josef; Turin, Tanvir Chowdhury; Matsushita, Kunihiro; Sang, Yingying; Ballew, Shoshana H; Appel, Lawrence J; Arima, Hisatomi; Chadban, Steven J; Cirillo, Massimo; Djurdjev, Ognjenka; Green, Jamie A; Heine, Gunnar H; Inker, Lesley A; Irie, Fujiko; Ishani, Areef; Ix, Joachim H; Kovesdy, Csaba P; Marks, Angharad; Ohkubo, Takayoshi; Shalev, Varda; Shankar, Anoop; Wen, Chi Pang; de Jong, Paul E; Iseki, Kunitoshi; Stengel, Benedicte; Gansevoort, Ron T; Levey, Andrew S

    2014-06-25

    The established chronic kidney disease (CKD) progression end point of end-stage renal disease (ESRD) or a doubling of serum creatinine concentration (corresponding to a change in estimated glomerular filtration rate [GFR] of −57% or greater) is a late event. To characterize the association of decline in estimated GFR with subsequent progression to ESRD with implications for using lesser declines in estimated GFR as potential alternative end points for CKD progression. Because most people with CKD die before reaching ESRD, mortality risk also was investigated. Individual meta-analysis of 1.7 million participants with 12,344 ESRD events and 223,944 deaths from 35 cohorts in the CKD Prognosis Consortium with a repeated measure of serum creatinine concentration over 1 to 3 years and outcome data. Transfer of individual participant data or standardized analysis of outputs for random-effects meta-analysis conducted between July 2012 and September 2013, with baseline estimated GFR values collected from 1975 through 2012. End-stage renal disease (initiation of dialysis or transplantation) or all-cause mortality risk related to percentage change in estimated GFR over 2 years, adjusted for potential confounders and first estimated GFR. The adjusted hazard ratios (HRs) of ESRD and mortality were higher with larger estimated GFR decline. Among participants with baseline estimated GFR of less than 60 mL/min/1.73 m2, the adjusted HRs for ESRD were 32.1 (95% CI, 22.3-46.3) for changes of −57% in estimated GFR and 5.4 (95% CI, 4.5-6.4) for changes of −30%. However, changes of −30% or greater (6.9% [95% CI, 6.4%-7.4%] of the entire consortium) were more common than changes of −57% (0.79% [95% CI, 0.52%-1.06%]). This association was strong and consistent across the length of the baseline period (1 to 3 years), baseline estimated GFR, age, diabetes status, or albuminuria. Average adjusted 10-year risk of ESRD (in patients with a baseline estimated GFR of 35 mL/min/1.73 m2

  19. The influence of a cooked-meat meal on estimated glomerular filtration rate.

    Science.gov (United States)

    Preiss, David J; Godber, Ian M; Lamb, Edmund J; Dalton, R Neil; Gunn, Ian R

    2007-01-01

    Chronic kidney disease (CKD) is an important but under-recognized condition. Recent national guidelines have recommended that biochemistry laboratories report estimated GFR (eGFR) to improve diagnosis of CKD and facilitate disease staging and management. Previous reports have suggested that intake of large amounts of cooked meat can lead to a significant increase in serum creatinine concentration. Participants (n = 32), consisting of 17 healthy volunteers and 15 outpatients, were recruited. Measurement of serum creatinine (kinetic Jaffe method, enzymatic, isotope-dilution mass spectrometry [IDMS]) and cystatin C, and calculation of eGFR were carried out before (i) and after a meal containing cooked meat (ii) and a meat-free meal (iii). Following intake of cooked meat, median serum creatinine concentration (kinetic Jaffe) increased from 80.5 micromol/L preprandially to 101.0 micromol/L 1-2 h postprandially (Pcooked meat has a significant effect on serum creatinine concentration and eGFR. Misclassification of CKD is possible if measurements are made after meals containing cooked meat. Clinicians should ensure that CKD classification is based on samples taken in the appropriate conditions: either fasting or after avoidance of cooked meat on the day of sampling. National guidelines which overlook this factor should be revisited.

  20. Reliability of estimated glomerular filtration rate in patients treated with platinum containing therapy

    DEFF Research Database (Denmark)

    Lauritsen, Jakob; Gundgaard, Maria G; Mortensen, Mette S

    2014-01-01

    (median percentage error), precision (median absolute percentage error) and accuracy (p10 and p30). The precision of carboplatin dosage based on eGFR was calculated. Data on mGFR, eGFR, and PCr were available in 390 patients, with a total of ∼ 1,600 measurements. Median PCr and mGFR synchronically...... decreased after chemotherapy, yielding high bias and low precision of most estimates. Post-chemotherapy, bias ranged from -0.2% (MDRD after four cycles) to 33.8% (CKD-EPI after five cycles+), precision ranged from 11.6% (MDRD after four cycles) to 33.8% (CKD-EPI after five cycles+) and accuracy (p30) ranged...... from 37.5% (CKD-EPI after five cycles+) to 86.9% (MDRD after four cycles). Although MDRD appeared acceptable after chemotherapy because of high accuracy, this equation underestimated GFR in all other measurements. Before and years after treatment, Cockcroft-Gault and Wright offered best results...

  1. Stable glomerular filtration rate in normotensive IDDM patients with stable microalbuminuria. A 5-year prospective study

    DEFF Research Database (Denmark)

    Mathiesen, E R; Feldt-Rasmussen, B; Hommel, E

    1997-01-01

    patients with persistent microalbuminuria (mean urinary albumin excretion [UAE] 84 mg/24 h [range 30-300]) were followed prospectively for 5 years of clinical examinations that included the measurement of GFR (51Cr-labeled EDTA clearance) at least once a year. The mean GFR at baseline was 120 +/- 18 ml x....... Out of 40 patients, 14 progressed to diabetic nephropathy (UAE > 300 mg/24 h). These patients had a significant reduction in GFR (mean -2.2 +/- 3.8 ml x min-1 x year-1; P = 0.05), while GFR remained stable in the remaining 26 patients with nonprogressive microalbuminuria (change in GFR 0.5 +/- 2.1 ml...

  2. Do similar factors control the glomerular filtration rate of superficial and juxtamedullary nephrons

    International Nuclear Information System (INIS)

    Rouffignac, C. de

    1975-01-01

    The SNGFR intrarenal distribution was studied under conditions where the whole kidney GFR remains unchanged and then where it is altered as compared to the normal non diuretic state. Only data obtained from experiments in which the SNGFR of both superficial and juxtamedullary nephrons were measured with the same techniques were reported. The superficial over juxtamedullary SNGFR ratio appears to be relatively stable and independent of physiological conditions. Nevertheless, in cases which indicate changes in the SNGFR intrarenal distribution, these changes remain always of limited magnitude. Thus it seems possible to conclude, that the SNGFR is controlled by factors that act, at least qualitatively, in the same manner in the whole nephron population [fr

  3. Lower estimated glomerular filtration rate and higher albuminuria are associated with mortality and end-stage renal disease. A collaborative meta-analysis of kidney disease population cohorts

    DEFF Research Database (Denmark)

    Astor, Brad C; Matsushita, Kunihiro; Gansevoort, Ron T

    2011-01-01

    We studied here the independent associations of estimated glomerular filtration rate (eGFR) and albuminuria with mortality and end-stage renal disease (ESRD) in individuals with chronic kidney disease (CKD). We performed a collaborative meta-analysis of 13 studies totaling 21,688 patients selected...

  4. A comparison of estimated glomerular filtration rates using Cockcroft-Gault and the Chronic Kidney Disease Epidemiology Collaboration estimating equations in HIV infection

    DEFF Research Database (Denmark)

    Mocroft, A; Nielsen, Lene Ryom; Reiss, P

    2014-01-01

    The aim of this study was to determine whether the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI)- or Cockcroft-Gault (CG)-based estimated glomerular filtration rates (eGFRs) performs better in the cohort setting for predicting moderate/advanced chronic kidney disease (CKD) or end...

  5. Glomerular filtration rate is associated with free triiodothyronine in euthyroid subjects : Comparison between various equations to estimate renal function and creatinine clearance

    NARCIS (Netherlands)

    Anderson, Josephine L C; Gruppen, Eke G; van Tienhoven-Wind, Lynnda; Eisenga, Michele F; de Vries, Hanne; Gansevoort, Ron T; Bakker, Stephan J L; Dullaart, Robin P F

    BACKGROUND: Effects of variations in thyroid function within the euthyroid range on renal function are unclear. Cystatin C-based equations to estimate glomerular filtration rate (GFR) are currently advocated for mortality and renal risk prediction. However, the applicability of cystatin C-based

  6. Influence of filtration and glucose amendment on bacterial growth rate at different tidal conditions in the Minho Estuary River (NW Portugal)

    DEFF Research Database (Denmark)

    Anne, I.; Fidalgo, M. L.; Thosthrup, L.

    2006-01-01

    Bacterioplankton abundance, biomass and growth rates were studied in the Minho Estuary River (NW Portugal). The influence of tidal conditions, glucose amendment, and the filtration process on total bacterial abundance, total and faecal coliforms, as well as faecal streptococci, were evaluated...

  7. Lower estimated glomerular filtration rate and higher albuminuria are associated with all-cause and cardiovascular mortality. A collaborative meta-analysis of high-risk population cohorts

    NARCIS (Netherlands)

    van der Velde, Marije; Matsushita, Kunihiro; Coresh, Josef; Astor, Brad C.; Woodward, Mark; Levey, Andrew S.; de Jong, Paul E.; Gansevoort, Ron T.

    Screening for chronic kidney disease is recommended in people at high risk, but data on the independent and combined associations of estimated glomerular filtration rate (eGFR) and albuminuria with all-cause and cardiovascular mortality are limited. To clarify this, we performed a collaborative

  8.  A Comparison of Serum Cystatin C and Creatinine with Glomerular FiltrationRate in Indian Patients with Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ramanathan Kumaresan

    2011-11-01

    Full Text Available  Objectives: There is no literature available on the performance of cystatin C in Chronic Kidney Disease (CKD patients of Indian population based on age group. Hence, this study is aimed to compare the diagnostic performance of serum cystatin C and creatinine with measured glomerular filtration rate (GFR and estimated GFR (eGFR in subjects of Indian origin. Methods: The study was carried out at Tiruchirappalli, South India during the period of September 2010 to march 2011. One hundred and six CKD patients (82 males, 24 females were enrolled and categorized into three groups based on age. The eGFR was calculated using Cockcroft-Gault (CG and Modification of Diet in Renal Disease (MDRD formulae. Serum cystatin C was measured with a particle-enhanced nephelometric immunoassay (PENIA method. GFR was measured using 99mTC - diethylene triamine penta aceticacid (DTPA renal scan method. Results: Serum cystatin C showed significant correlation with measured GFR in all the three groups (r=-0.9735, r=-0.8975 and r=-0.7994 respectively than serum creatinine (r=-0.7380, r=- 0.6852 and r=-0.5127 respectively. Conclusion: Serum cystatin C showed a high correlation with measured GFR in young and older patients with CKD than creatinine. Thus, cystatin C is a good alternative marker to creatinine in CKD patients.

  9. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  10. Depression and Quality of Life in Relation to Decreased Glomerular Filtration Rate Among Adults with Hypertension in Rural Northeast China

    Directory of Open Access Journals (Sweden)

    Xiaofan Guo

    2015-02-01

    Full Text Available Background/Aims: We aim to investigate the extent to which depression and quality of life might be associated with decreased glomerular filtration rate (GFR in a large hypertensive population in rural Northeast China. Methods: A total of 5566 hypertensive participants aged 35 years and older were screened with a stratified cluster multistage sampling scheme in rural areas of Liaoning Province during 2012-2013. Decreased GFR was defined as estimated GFR 2. Results: The overall prevalence of decreased GFR was 3.2%. In the multivariable regression model, participants with moderate or greater depression had a greater risk for having a decreased GFR (OR: 1.739, 95%CI: 1.004 to 3.014 after full adjustment. Every 1-point increase of all the domains in WHOQOL-BREF, except for physical and environment domains, was significantly related to a lower risk for decreased GFR adjusting for age, gender and race. However, after fully adjustment, only social relations remained significant (OR: 0.899, 95%CI: 0.820 to 0.985. Increasing in total scores of WHOQOL-BREF was a protective factor against decreased GFR after fully adjustment. Conclusion: We found that moderate or greater depression and lower quality of life were associated with higher risks for developing decreased GFR.

  11. Clinical Relevance of Differences in Glomerular Filtration Rate Estimations in Frail Older People by Creatinine- vs. Cystatin C-Based Formulae.

    Science.gov (United States)

    Jacobs, Anne; Benraad, Carolien; Wetzels, Jack; Rikkert, Marcel Olde; Kramers, Cornelis

    2017-06-01

    The risk of incorrect medication dosing is high in frail older people. Therefore, accurate assessment of the glomerular filtration rate is important. The objective of this study was to compare the estimated glomerular filtration rate using creatinine- and cystatin C-based formulae, the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in frail older people. We hypothesized that frailty determines the difference between the creatinine- and cystatin C-based formulae. The mean difference between CKD-EPI creatinine and cystatin C was determined using (cross-sectional) data of 55 patients (mean age 73 years) admitted to a psychiatric ward for older adults. The level of agreement of these estimations was assessed by a Bland-Altman analysis. In all patients, the Rockwood's Frailty Index was derived and correlated with the mean difference between CKD-EPI creatinine and cystatin C. The mean difference between CKD-EPI creatinine (mean 71.2 mL/min/1.73 m 2 ) and CKD-EPI cystatin C (mean 57.6 mL/min/1.73 m 2 ) was 13.6 mL/min/1.73 m 2 (p creatinine- and cystatin C-based glomerular filtration rate (Pearson correlation coefficient 0.182, p = 0.184). There was a significant gap between a creatinine- and cystatin C-based estimation of glomerular filtration rate, irrespective of frailty. The range of differences between the commonly used estimated glomerular filtration rate formulae might result in clinically relevant differences in drug prescription and differences in chronic kidney disease staging.

  12. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    Science.gov (United States)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Wu, Chun-Han; Lin, Yu-Cheng

    2014-09-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood.

  13. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    International Nuclear Information System (INIS)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Lin, Yu-Cheng; Wu, Chun-Han

    2014-01-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood. (paper)

  14. Changes in glomerular filtration rate, lithium clearance and plasma protein clearances in the early phase after unilateral nephrectomy in living healthy renal transplant donors

    DEFF Research Database (Denmark)

    Strandgaard, S; Kamper, A; Skaarup, P

    1988-01-01

    1. Glomerular and tubular function was studied before and 2 months after unilateral nephrectomy in 14 healthy kidney donors by measurement of the clearances of 51Cr-labelled ethylenediaminetetra-acetate, lithium, beta 2-microglobulin, albumin and immunoglobulin G. 2. The glomerular filtration rat...

  15. Association Between Obesity and Chronic Kidney Disease, Defined by Both Glomerular Filtration Rate and Albuminuria, in Korean Adults.

    Science.gov (United States)

    Kim, Yoon Ji; Hwang, Seun Deuk; Oh, Tae Jung; Kim, Kyoung Min; Jang, Hak Chul; Kimm, Heejin; Kim, Hyeon Chang; Jee, Sun Ha; Lim, Soo

    2017-10-01

    Chronic kidney disease (CKD) has often been defined based on glomerular filtration rate (GFR) alone. The Kidney Disease: Improving Global Outcomes guideline highlights albuminuria in the CKD definition. Thus, we investigated the association between obesity and CKD, as defined by both GFR and albuminuria, in Korean adults. We used Korea National Health and Nutrition Examination Survey 2011-2014 data (N = 19,331, ≥19 years old) representing the national Korean population. CKD was classified by (1) estimated GFR (eGFR) obesity and each CKD category were evaluated using multivariate logistic regression analysis. The prevalence rates of CKD GFR , CKD ACR , and CKD Risk were 2.2%, 6.7%, and 8.1%, respectively. Compared with the normal body mass index (BMI; 18.5-22.9 kg/m 2 ) group, men with BMI ≥ 25 kg/m 2 had 1.88 times greater risk of CKD GFR in the adjusted model [95% confidence interval (CI), 1.26-2.80; P = 0.002]; BMI was not significantly associated with CKD GFR in women. In contrast, both men and women with BMI ≥ 25 kg/m 2 had 1.58 and 1.40 times higher risk of CKD ACR (95% CI, 1.21-2.07 and 1.08-1.81, respectively, both P Obese men and women had 1.65 and 1.38 times higher risk of CKD Risk (95% CI, 1.29-2.12 and 1.09-1.75, respectively, both P Obesity was significantly associated with an increased ACR-based CKD risk. Longitudinal studies are needed to investigate the role of overweight and obesity in the development and progression of CKD.

  16. Estimation of the glomerular filtration rate in infants and children using iohexol and X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Stake, G.

    1992-01-01

    The aim of the present study was to establish methods for the estimation of the glomerular filtration rate (GFR) in children. The conclusions and clinical implications of the study are as follows: Urography with iohexol in children had no significant influence on the GFR. Valid GFR estimates were calculated from the plasma disappearance rate obtained from two plasma samples taken three and four hour after the injection of iohexol. Both iohexol and metrizoate caused a transitory, increased renal excretion of alkaline phosphatase. GFR as well as the excretion of albumin and β 2 -microglobulin were unchanged. Using the weight-related empirical distribution volume for determination of GFR from the plasma sample taken three hour after the injection of iohexol, a high degree of agreement was found between the preliminary single sample GFR estimate and the reference, two plasma sample GFR. However, the relationship was curvilinear, and in order to obtain a value for the final three hour single sample GFR equal to the reference GFR, the preliminary value had to be corrected by a second degree correction factor. The day-to-day variations of GFRs estimated with the iohexol methods were similar to those obtained with other standard methods. In another group of infants and children, independent, but otherwise comparable to the patients who formed the basis for the single sample iohexol method, it was confirmed that valid GFR estimates were obtained from the three hour single plasma sample. GFR determinations from one hour, two hour, and four hour single samples further supported that the optimal sampling time in patients with GFR down to 20 ml per minute -1 1.73 m -2 was three hours. 53 refs., 5 figs

  17. True mean rate measuring system

    International Nuclear Information System (INIS)

    Eichenlaub, D.P.

    1980-01-01

    A digital radiation-monitoring system for nuclear power plants uses digital and microprocessor circuitry to enable rapid processing of pulse information from remote radiation monitors. The pulse rates are analyzed to determine whether new pulse-rate information is statisticaly the same as that previously received and to determine the best possible averaging time, which can be changed so that the statistical error remains below a specified level while the system response time remains short. Several data modules each process the pulse-rate information from several remote radiation monitors. Each data module accepts pulse data from each radiation monitor and measures the true average or mean pulse rate of events occurring with a Poisson distribution to determine the radiation level. They then develop digital output signals which indciate the respective radiation levels and which can be transmitted via multiplexer circuits for additional processing and display. The data modules can accept signals from remote control stations or computer stations via the multiplexer circuit to change operating thresholds and alarm levels in their memories. A check module scans the various data modules to determine whether the output signals are valid. It also acts as a redundant data module and will automatically replace an inoperative unit. (DN)

  18. Comparative Performance of Creatinine-Based Estimated Glomerular Filtration Rate Equations in the Malays: A Pilot Study in Tertiary Hospital in Malaysia

    Directory of Open Access Journals (Sweden)

    Maisarah Jalalonmuhali

    2017-01-01

    Full Text Available Aim. To validate the accuracy of estimated glomerular filtration rate (eGFR equations in Malay population attending our hospital in comparison with radiolabeled measured GFR. Methods. A cross-sectional study recruiting volunteered patients in the outpatient setting. Chromium EDTA (51Cr-EDTA was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA, four-variable Modification of Diet in Renal Disease (4-MDRD, and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations were calculated. Results. A total of 51 subjects were recruited with mean measured GFR 42.04 (17.70–111.10 ml/min/1.73 m2. Estimated GFR based on CGBSA, 4-MDRD, and CKD-EPI were 40.47 (16.52–115.52, 35.90 (14.00–98.00, and 37.24 (14.00–121.00, respectively. Higher accuracy was noted in 4-MDRD equations throughout all GFR groups except for subgroup of GFR ≥ 60 ml/min/1.73 m2 where CGBSA was better. Conclusions. The 4-MDRD equation seems to perform better in estimating GFR in Malay CKD patients generally and specifically in the subgroup of GFR < 60 ml/min/1.73 m2 and both BMI subgroups.

  19. Clinical benefits of using inulin clearance and cystatin C for determining glomerular filtration rate in HIV-1-infected individuals treated with dolutegravir.

    Science.gov (United States)

    Yukawa, Satomi; Watanabe, Dai; Uehira, Tomoko; Shirasaka, Takuma

    2018-03-01

    Dolutegravir may inhibit creatinine transporters in renal tubules and elevate serum creatinine levels. We investigated the usefulness of glomerular filtration rate (GFR) measured using inulin clearance (Cin), creatinine clearance (Ccr), and estimated GFR based on both serum creatinine (eGFRcre) and serum cystatin C (eGFRcys). HIV-1-infected Japanese patients with suppressed viremia and whose antiretroviral drug was switched to dolutegravir from other drugs were included (n = 108, Study 1). We compared eGFRcre and eGFRcys at the start and after 48 weeks of dolutegravir administration. For the patients providing consent, we measured Cin and Ccr (n = 15, Study 2). We assessed biases and accuracy and compared Cin with eGFRcre, eGFRcys, and Ccr. There were no differences in serum cystatin C and eGFRcys between baseline and at 48 weeks. Moreover, eGFRcre was significantly less accurate (within 30% of measured GFR) than both eGFRcys and Ccr (40% accuracy compared to 93% and 93%, respectively). eGFRcys was significantly less biased than eGFRcre and Ccr (p inulin clearance and eGFRcys. This is the first study performing inulin clearance for HIV-1-infected individuals and to show data for eGFRcys from a large cohort following a switch to dolutegravir from other antiretroviral agents. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Measured and estimated glomerular filtration rate. Numerous methods of measurements (Part I

    Directory of Open Access Journals (Sweden)

    Jaime Pérez Loredo

    2017-04-01

    Equations applied for estimating GFR in population studies, should be reconsidered, given their imperfection and the difficulty for clinicians, who are not specialists on the subject, to interpret the results.

  1. Estimated Glomerular Filtration Rate Correlates Poorly with Four-Hour Creatinine Clearance in Critically Ill Patients with Acute Kidney Injury

    Directory of Open Access Journals (Sweden)

    Christopher J. Kirwan

    2013-01-01

    Full Text Available Introduction. RIFLE and AKIN provide a standardised classification of acute kidney injury (AKI, but their categorical rather than continuous nature restricts their use to a research tool. A more accurate real-time description of renal function in AKI is needed, and some published data suggest that equations based on serum creatinine that estimate glomerular filtration rate (eGFR can provide this. In addition, incorporating serum cystatin C concentration into estimates of GFR may improve their accuracy, but no eGFR equations are validated in critically ill patients with AKI. Aim. This study tests whether creatinine or cystatin-C-based eGFR equations, used in patients with CKD, offer an accurate representation of 4-hour creatinine clearance (4CrCl in critically ill patients with AKI. Methods. Fifty-one critically ill patients with AKI were recruited. Thirty-seven met inclusion criteria, and the performance of eGFR equations was compared to 4CrCl. Results. eGFR equations were better than creatinine alone at predicting 4CrCl. Adding cystatin C to estimates did not improve the bias or add accuracy. The MDRD 7 eGFR had the best combination of correlation, bias, percentage error and accuracy. None were near acceptable standards quoted in patients with chronic kidney disease (CKD. Conclusions. eGFR equations are not sufficiently accurate for use in critically ill patients with AKI. Incorporating serum cystatin C does not improve estimates. eGFR should not be used to describe renal function in patients with AKI. Standards of accuracy for validating eGFR need to be set.

  2. The impairment of true glomerular filtration rate in long-term cyclosporine-treated pediatric allograft recipients

    International Nuclear Information System (INIS)

    McDiarmid, S.V.; Ettenger, R.B.; Hawkins, R.A.; Senguttvan, P.; Busuttil, R.W.; Vargas, J.; Berquist, W.E.; Ament, M.E.

    1990-01-01

    We performed indium-111-DTPA plasma clearance studies in 61 pediatric kidney and liver recipients treated with cyclosporine to compare true glomerular filtration rate with calculated GFR (cGFR). The mean true GFR of 61.9 +/- 36.6 ml/min/1.73 m2 indicated renal impairment. The mean cGFR of 85.2 +/- 22.4 ml/min/1.73 m2 was significantly higher (P less than 0.001), and overestimated GFR by 38%. cGFR alone did not accurately reflect the degree of renal dysfunction. A group of 48 pediatric orthotopic liver transplant recipients was studied in more detail: 73% of these patients had a true GFR less than 70 ml/min/1.73 m2, while 85% had a true GFR below 90 ml/min/1.73 m2, the lower limit for normal GFR in children. The mean true GFR for patients treated more than 24 months with CsA was lower (P = 0.02) than patients treated with CsA for 12 to 24 months. OLT patients with normal true GFR (greater than 90 ml/min/1.73 m2) had significantly lower plasma CsA levels, and 50% of patients with a true GFR less than or equal to 50 ml/min/1.73 m2 had hypertension. There was no effect on true GFR of age, liver function, azathioprine use, or peritransplant treatment with other nephrotoxic drugs. We conclude that true GFR is significantly impaired in long-term CsA-treated allograft pediatric recipients. Calculations of GFR underestimate the degree of renal dysfunction. As patients treated greater than 24 months had the lowest true GFRs, the fall in GFR may be progressive

  3. Gender, renal function, and outcomes on the liver transplant waiting list: assessment of revised MELD including estimated glomerular filtration rate.

    Science.gov (United States)

    Myers, Robert P; Shaheen, Abdel Aziz M; Aspinall, Alexander I; Quinn, Robert R; Burak, Kelly W

    2011-03-01

    The Model for End-Stage Liver Disease (MELD) allocation system for liver transplantation (LT) may present a disadvantage for women by including serum creatinine, which is typically lower in females. Our objectives were to investigate gender disparities in outcomes among LT candidates and to assess a revised MELD, including estimated glomerular filtration rate (eGFR), for predicting waiting list mortality. Adults registered for LT between 2002 and 2007 were identified using the UNOS database. We compared components of MELD, MDRD-derived eGFR, and the 3-month probability of LT and death between genders. Discrimination of MELD, MELDNa, and revised models including eGFR for mortality were compared using c-statistics. A total of 40,393 patients (36% female) met the inclusion criteria; 9% died and 24% underwent LT within 3 months of listing. Compared with men, women had lower median serum creatinine (0.9 vs. 1.0 mg/dl), eGFR (72 vs. 83 ml/min/1.73 m(2)), and mean MELD (16.5 vs. 17.2; all p discrimination for 3-month mortality (c-statistics: MELD 0.896, MELD-eGFR 0.894, MELDNa 0.911, MELDNa-eGFR 0.905). Women are disadvantaged under MELD potentially due to its inclusion of creatinine. However, since including eGFR in MELD does not improve mortality prediction, alternative refinements are necessary. Copyright © 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  4. Factors Affecting Changes in the Glomerular Filtration Rate after Unilateral Nephrectomy in Living Kidney Donors and Patients with Renal Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Ok; Chae, Sun Young; Back, Sora; Moon, Dae Hyuk [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2010-04-15

    We evaluated the factors affecting changes in the postoperative glomerular filtration rate (GFR) after unilateral nephrectomy in living kidney donors and patients with renal disease. We studied 141 subjects who underwent living donor nephrectomy for renal transplantation (n=75) or unilateral nephrectomy for renal diseases (n=66). The GFR of the individual kidney was determined by Tc-99m DTPA scintigraphy before and after nephrectomy. By performing multiple linear regression analysis, we evaluated the factors that are thought to affect changes in GFR, such as age, sex, body mass index (BMI), preoperative GFR, preoperative creatinine level, operated side, presence of diabetes mellitus (DM), presence of hypertension (HTN), and duration of follow-up. In both the donor nephrectomy and the disease nephrectomy groups, GFR increased significantly after nephrectomy (46.9{+-}8.4 to 58.1{+-}12.5 vs. 43.0{+-}9.6 to 48.6{+-}12.8 ml/min, p<0.05). In the donor nephrectomy group, age was significantly associated with change in GFR ({beta}=-0.3, P<0.005). In the disease nephrectomy group, HTN, preoperative creatinine level, and age were significantly associated with change in GFR ({beta}=-6.2, p<0.005; {beta}=-10.9, p<0.01; {beta}=-0.2, p<0.01, respectively). This compensatory change in GFR was not significantly related to sex, duration of follow-up, or operated side in either group. The compensatory change in the GFR of the remaining kidney declined with increasing age in both living kidney donors and patients with renal disease.

  5. [Concordance of glomerular filtration rate with creatinine clearance in 24-hour urine and Schwartz and Schwartz updated].

    Science.gov (United States)

    Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne

    Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  6. Albuminuria and neck circumference are determinate factors of successful accurate estimation of glomerular filtration rate in high cardiovascular risk patients.

    Directory of Open Access Journals (Sweden)

    Po-Jen Hsiao

    Full Text Available Estimated glomerular filtration rate (eGFR is used for diagnosis of chronic kidney disease (CKD. The eGFR models based on serum creatinine or cystatin C are used more in clinical practice. Albuminuria and neck circumference are associated with CKD and may have correlations with eGFR.We explored the correlations and modelling formulates among various indicators such as serum creatinine, cystatin C, albuminuria, and neck circumference for eGFR.Cross-sectional study.We reviewed the records of patients with high cardiovascular risk from 2010 to 2011 in Taiwan. 24-hour urine creatinine clearance was used as the standard. We utilized a decision tree to select for variables and adopted a stepwise regression method to generate five models. Model 1 was based on only serum creatinine and was adjusted for age and gender. Model 2 added serum cystatin C, models 3 and 4 added albuminuria and neck circumference, respectively. Model 5 simultaneously added both albuminuria and neck circumference.Total 177 patients were recruited in this study. In model 1, the bias was 2.01 and its precision was 14.04. In model 2, the bias was reduced to 1.86 with a precision of 13.48. The bias of model 3 was 1.49 with a precision of 12.89, and the bias for model 4 was 1.74 with a precision of 12.97. In model 5, the bias could be lower to 1.40 with a precision of 12.53.In this study, the predicting ability of eGFR was improved after the addition of serum cystatin C compared to serum creatinine alone. The bias was more significantly reduced by the calculation of albuminuria. Furthermore, the model generated by combined albuminuria and neck circumference could provide the best eGFR predictions among these five eGFR models. Neck circumference can be investigated potentially in the further studies.

  7. The effects of protein intake on albuminuria in different estimated glomerular filtration rate: A population-based study.

    Science.gov (United States)

    Liu, Yan; Tan, Rong-Shao; Zhou, Dao-Yuan; Xiao, Xiao; Ran, Jian-Min; Qin, Dan-Ping; Zhong, Xiao-Shi; Hu, Jian-Guang; Liu, Yun; Zheng, Yuan-Yuan

    2018-02-01

    Chronic kidney disease (CKD) is a serious condition associated with early mortality, decreased quality of life, and increased health-care expenditures. Data from the National Health and Nutrition Examination Survey (NHANES) collected from 1999 to 2012 were used. Subjects were divided into 4 estimated glomerular filtration rate (eGFR) categories: stage 1: eGFR≥90mL/min/1.73m 2 , stage 2: eGFR 60-89, stage 3: eGFR 30-59, and stage 4/5: eGFRprotein intake and albuminuria were determined. A total of 45,259 subjects were included. Despite decreasing protein intake, there was a significant increase in the prevalence of albuminuria with decreasing levels of eGFR. Multivariable analysis showed that albuminuria was associated with daily protein intake in patients ≥65years old with stage 1 disease, and that diabetes was associated with albuminuria in patients ≥65years old with stage 2 and 3 diseases. Overall, albuminuria in patients with stage 1 disease was associated with hours of sitting per day and blood glucose level. Albuminuria was associated with daily protein intake in patients of 45-64years old with stage 1 CKD disease, and was associated with hours of sitting per day and blood glucose level. These data further support the importance of lifestyle changes in the management of CKD, especially in patients with early-stage disease. Copyright © 2017 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  8. Pre-procedural peripheral endothelial function is associated with increased serum creatinine following percutaneous coronary procedure in stable patients with a preserved estimated glomerular filtration rate.

    Science.gov (United States)

    Sumida, Hitoshi; Matsuzawa, Yasushi; Sugiyama, Seigo; Sugamura, Koichi; Nozaki, Toshimitsu; Akiyama, Eiichi; Ohba, Keisuke; Konishi, Masaaki; Matsubara, Junichi; Fujisue, Koichiro; Maeda, Hirofumi; Kurokawa, Hirofumi; Iwashita, Satomi; Ogawa, Hisao; Tsujita, Kenichi

    2017-11-01

    Worsening renal function, indicated by increased serum creatinine (SCr), is a common complication of percutaneous coronary procedures. Risk factors for increased SCr overlap with coronary risk factors involved in endothelial dysfunction. We hypothesized that endothelial dysfunction, measured using the reactive hyperemia peripheral arterial tonometry index (RHI), can predict periprocedure-increased SCr. RHI was assessed before elective coronary procedures in 316 consecutive stable patients with a preserved estimated glomerular filtration rate (eGFR, >60mL/min/1.73m 2 ). SCr was measured before and 2 days after procedures. There was no significant correlation between natural logarithmic transformations of RHI (Ln-RHI) and basal Ln-eGFR. Periprocedure increase in SCr was observed in 148 (47%) patients. The increased SCr group had significantly lower Ln-RHI [0.48 (0.36, 0.62) vs. 0.59 (0.49, 0.76), pfunction by RHI is an effective strategy to assess the patient's risk conditions for worsening renal function after percutaneous coronary procedures. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Filtration and clearance rates of Anadara grandis juveniles (Pelecypoda, Arcidae with different temperatures and suspended matter concentrations

    Directory of Open Access Journals (Sweden)

    Anselmo Miranda-Baeza

    2006-09-01

    Full Text Available The mangrove cockle Anadara grandis (Broderip and Sowerby, 1829 is a potential candidate for aquaculture and for bioremediation of aquaculture effluents in the tropical and subtropical coastal areas of the eastern Pacific Ocean. Laboratory-produced spat are available, but there is no information on their responses to the range of environmental conditions to which they might be subject during the growth cycle. The aim of this study was to evaluate the filtration and clearance rates of A. grandis spat (shell length 9.50±0.37 mm with a food concentration (7.5 mg∙l-1 at four different temperatures (22, 25, 28 and 31 ºC, with pH = 7.5±0.2 and O2 concentration of 6.4±0.5 mg·l-1; experiment one; and with a temperature (25 °C and five concentrations of suspended matter (from 7.5 to 29 mg·l-1 and pH and O2 values of 7.9±0.2 and 6.8± 0.4 mg·l-1; experiment two. Filtration and clearance rates were highest at 25 ºC and significantly different (p.05. In the second experiment filtration increased according to the amount of food available, but there were no significant differences (p>.05 between 7.5 and 11 mg·l-1 and from 22.4 to 29 mg·l-1. The trend was similar for clearance, and in this case significant differences were found (pLa almeja Anadara grandis (Broderip and Sowerby, 1829 es un candidato potencial para la acuicultura y la biorremediación de efluentes acuícolas en las áreas costeras tropicales y subtropicales del océano Pacífico oriental. Se dispone de semilla producida en laboratorio, sin embargo no hay información sobre sus respuestas a los intervalos de las condiciones ambientales a las cuales puede estar sujeta durante el periodo de crecimiento. El objetivo de este estudio fue evaluar las tasas de filtración y de clarificación de semilla de A. grandis (largo de la concha= 9.50±0.37 mm con una concentración de alimento (7.5 mg∙l-1 y cuatro diferentes temperaturas (22, 25, 28 y 31 °C con pH= 7.5±0.2, concentración de O

  10. BWR condensate filtration studies

    International Nuclear Information System (INIS)

    Wilson, J.A.; Pasricha, A.; Rekart, T.E.

    1993-09-01

    Poor removal of particulate corrosion products (especially iron) from condensate is one of the major problems in BWR systems. The presence of activated corrosion products creates ''hot spots'' and increases piping dose rates. Also, fuel efficiency is reduced and the risk of fuel failure is increased by the deposit of corrosion products on the fuel. Because of these concerns, current EPRI guidelines call for a maximum of 2 ppb of iron in the reactor feedwater with a level of 0.5 ppb being especially desirable. It has become clear that conventional deep bed resins are incapable of meeting these levels. While installation of prefilter systems is an option, it would be more economical for plants with naked deep beds to find an improved bead resin for use in existing systems. BWR condensate filtration technologies are being tested on a condensate side stream at Hope Creek Nuclear Generating Station. After two years of testing, hollow fiber filters (HFF) and fiber matrix filters (FMF), and low crosslink cation resin, all provide acceptable results. The results are presented for pressure drop, filtration efficiency, and water quality measurements. The costs are compared for backwashable non-precoat HFF and FMF. Results are also presented for full deep bed vessel tests of the low crosslink cation resin

  11. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  12. The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention

    DEFF Research Database (Denmark)

    Henriksen, Ulrik L; Henriksen, Jens H

    2014-01-01

    In subjects without fluid retention, the total plasma clearance of a renal filtration indicator (inulin, (99m) Tc-DTPA, (51) Cr-EDTA) is close to the urinary plasma clearance. Conversely, in patients with fluid retention (oedema, pleural effusions, ascites), there is a substantial discrepancy...

  13. A lower baseline glomerular filtration rate predicts high mortality and newly cerebrovascular accidents in acute ischemic stroke patients.

    Science.gov (United States)

    Dong, Kai; Huang, Xiaoqin; Zhang, Qian; Yu, Zhipeng; Ding, Jianping; Song, Haiqing

    2017-02-01

    Chronic kidney disease (CKD) is gradually recognized as an independent risk factor for cardiovascular and cardio-/cerebrovascular disease. This study aimed to examine the association of the estimated glomerular filtration rate (eGFR) and clinical outcomes at 3 months after the onset of ischemic stroke in a hospitalized Chinese population.Totally, 972 patients with acute ischemic stroke were enrolled into this study. Modified of Diet in Renal Disease (MDRD) equations were used to calculate eGFR and define CKD. The site and degree of the stenosis were examined. Patients were followed-up for 3 months. Endpoint events included all-cause death and newly ischemic events. The multivariate logistic model was used to determine the association between renal dysfunction and patients' outcomes.Of all patients, 130 patients (13.4%) had reduced eGFR (<60 mL/min/1.73 m), and 556 patients had a normal eGFR (≥90 mL/min/1.73 m). A total of 694 patients suffered from cerebral artery stenosis, in which 293 patients only had intracranial artery stenosis (ICAS), 110 only with extracranial carotid atherosclerotic stenosis (ECAS), and 301 with both ICAS and ECAS. The patients with eGFR <60 mL/min/1.73m had a higher proportion of death and newly ischemic events compared with those with a relatively normal eGFR. Multivariate analysis revealed that a baseline eGFR <60 mL/min/1.73 m increased the risk of mortality by 3.089-fold and newly ischemic events by 4.067-fold. In further analysis, a reduced eGFR was associated with increased rates of mortality and newly events both in ICAS patients and ECAS patients. However, only an increased risk of newly events was found as the degree of renal function deteriorated in ICAS patients (odds ratio = 8.169, 95% confidence interval = 2.445-14.127).A low baseline eGFR predicted a high mortality and newly ischemic events at 3 months in ischemic stroke patients. A low baseline eGFR was also a strong independent predictor for newly

  14. The relation of Complementary-Alternative Medicine use with glomerular filtration rate and depression in patients with chronic kidney disease at predialysis stage.

    Science.gov (United States)

    Esen, Bennur; Atay, Ahmet Engin; Gokmen, Emel Saglam; Karakoc, Ayten; Sari, Hakan; Sarisakal, Samprie; Kahvecioglu, Serdar; Kayabasi, Hasan; Sit, Dede

    2015-05-08

    Complementary and alternative medicine is a broad field of health including all health care practices and methods; and their accompanying theories and beliefs. In the present study, we aimed to examine the frequency of complementary-alternative medicine use, and its relation with glomerular filtration rate and depression in patients with chronic kidney disease at predialysis stage. A total of 1053 predialysis patients; 518 female and 535 male, that were followed up with chronic kidney disease for at least 3 months were enrolled into the study. Demographic features, biochemical parameters and findings of physical examination were recorded. Their compliance to diet, and knowledge about disease were questioned. Beck depression inventory and questionnaire regarding to complementary-alternative medicine use were performed. The overall frequency of complementary-alternative medicine use was 40.3% . Total ratio of herbal products was 46%. Complementary-alternative medicine use was significantly more frequent in female or single patients, and patients that informed about chronic kidney disease or under strict diet (p:0.007, p:0.016, p:0.02, p:0.016; respectively). When glomerular filtration rate of participants were considered, complementary-alternative medicine use was similar in different stages of kidney disease. Depression was observed in 41.9% of patients and significantly frequent in patients with alternative method use (p:0.002). Depression score was higher as creatinine increases and glomerular filtration rate decreases (p:0.002; r: 0,093). We determined that complementary-alternative medicine use gradually increases at predialysis stage as glomerular filtration rate decreases and there is a strict relation between complementary-alternative medicine use and depression or female gender. Disorder related stressors may lead to seeking of alternative methods. This article is protected by copyright. All rights reserved.

  15. Water filtration rate and infiltration/accumulation of low density lipoproteins in 3 different modes of endothelial/smooth muscle cell co-cultures.

    Science.gov (United States)

    Ding, ZuFeng; Fan, YuBo; Deng, XiaoYan

    2009-11-01

    Using different endothelial/smooth muscle cell co-culture modes to simulate the intimal structure of blood vessels, the water filtration rate and the infiltration/accumulation of LDL of the cultured cell layers were studied. The three cell culture modes of the study were: (i) The endothelial cell monolayer (EC/Phi); (ii) endothelial cells directly co-cultured on the smooth muscle cell monolayer (EC-SMC); (iii) endothelial cells and smooth muscle cells cultured on different sides of a Millicell-CM membrane (EC/SMC). It was found that under the same condition, the water filtration rate was the lowest for the EC/SMC mode and the highest for the EC/Phi mode, while the infiltration/accumulation of DiI-LDLs was the lowest in the EC/Phi mode and the highest in the EC-SMC mode. It was also found that DiI-LDL infiltration/accumulation in the cultured cell layers increased with the increasing water filtration rate. The results from the in vitro model study therefore suggest that the infiltration/accumulation of the lipids within the arterial wall is positively correlated with concentration polarization of atherogenic lipids, and the integrity of the endothelium plays an important role in the penetration and accumulation of atherogenic lipids in blood vessel walls.

  16. Comparison of creatinine and cystatin C based eGFR in the estimation of glomerular filtration rate in Indigenous Australians: The eGFR Study.

    Science.gov (United States)

    Barr, Elizabeth Lm; Maple-Brown, Louise J; Barzi, Federica; Hughes, Jaquelyne T; Jerums, George; Ekinci, Elif I; Ellis, Andrew G; Jones, Graham Rd; Lawton, Paul D; Sajiv, Cherian; Majoni, Sandawana W; Brown, Alex Dh; Hoy, Wendy E; O'Dea, Kerin; Cass, Alan; MacIsaac, Richard J

    2017-04-01

    The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation that combines creatinine and cystatin C is superior to equations that include either measure alone in estimating glomerular filtration rate (GFR). However, whether cystatin C can provide any additional benefits in estimating GFR for Indigenous Australians, a population at high risk of end-stage kidney disease (ESKD) is unknown. Using a cross-sectional analysis from the eGFR Study of 654 Indigenous Australians at high risk of ESKD, eGFR was calculated using the CKD-EPI equations for serum creatinine (eGFRcr), cystatin C (eGFRcysC) and combined creatinine and cystatin C (eGFRcysC+cr). Reference GFR (mGFR) was determined using a non-isotopic iohexol plasma disappearance technique over 4h. Performance of each equation to mGFR was assessed by calculating bias, % bias, precision and accuracy for the total population, and according to age, sex, kidney disease, diabetes, obesity and c-reactive protein. Data were available for 542 participants (38% men, mean [sd] age 45 [14] years). Bias was significantly greater for eGFRcysC (15.0mL/min/1.73m 2 ; 95% CI 13.3-16.4, pcreatinine remains the preferred equation in Indigenous Australians. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes.

    Science.gov (United States)

    Szopa, Magdalena; Kapusta, Maria; Matejko, Bartlomiej; Klupa, Tomasz; Koblik, Teresa; Kiec-Wilk, Beata; Borowiec, Maciej; Malecki, Maciej T

    2015-01-01

    We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR) estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM), 70 with type 2 diabetes (T2DM), and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr) and CKD-EPI cystatin C equation (eGFR-cys), respectively. Cystatin C levels were lower (p MODY, GCK-MODY, and the controls (p = 0.004; p = 0.003; p MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  18. Plasma creatinine levels, estimated glomerular filtration rate and carotid intima media thickness in middle-aged women: a population based cohort study.

    Science.gov (United States)

    Gentile, M; Panico, S; Mattiello, A; de Michele, M; Iannuzzi, A; Jossa, F; Marotta, G; Rubba, P

    2014-06-01

    The relationships between high Creatinine (Cr) levels or low estimated Glomerular Filtration Rate (eGFR) and common carotid Intima Media thickness (IMT) have been evaluated in a population-based cohort study in women, aged 30-69 (Progetto ATENA). Serum Cr and eGFR were measured in 310 women, as a part of 5.062. In this group carotid ultrasound examination (B-Mode imaging) was performed and mean max IMT was calculated. Women were classified by Cr levels >1 mg/dL or eGFR Women with Cr > 1 mg/dL (90th percentile of creatinine distribution) or eGFR less than 56 ml/min (5th percentile of eGFR distribution) had relatively more carotid plaques as compared to the rest of the cohort. Multivariate logistic analysis, after adjustment for age, demonstrated a significant association between Cr (>1 mg/dL) and IMT (≥1.2 mm): OR 4.12 (C.I 1.22-13.86), p = 0.022; or eGFR (women, independently of age, suggest the value of screening for early carotid disease in asymptomatic middle aged-women with mild renal insufficiency, in order to predict those at relatively higher risk for future cardiovascular events. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  20. Estimated glomerular filtration rate is associated with both arterial stiffness and N-terminal pro-brain natriuretic peptide in newly diagnosed hypertensive patients.

    Science.gov (United States)

    Gür, Mustafa; Uçar, Hakan; Kuloğlu, Osman; Kıvrak, Ali; Şeker, Taner; Türkoğlu, Caner; Özaltun, Betül; Kaypaklı, Onur; Şahin, Durmuş Yıldıray; Elbasan, Zafer; Tanboğa, Halil İbrahim; Çaylı, Murat

    2014-01-01

    Even a slight decrease in the glomerular filtration rate (GFR) is an independent risk factor for cardiovascular disease. Arterial stiffness, left ventricular hypertrophy and N-terminal pro-brain natriuretic peptide (NT-proBNP) are independent risk factors for cardiovascular disease, which are particularly common in end-stage renal disease. We aimed to evaluate the association between GFR with arterial stiffness, left ventricle mass (LVM) and NT-proBNP in hypertensive subjects with normal to mildly impaired renal function. The study population consisted of 285 newly diagnosed hypertensive patients (mean age; 49.9 ± 11.8 years). GFR was estimated (eGFR) by the Modification of Diet in Renal Disease formula. Pulse wave velocity (PWV) and augmentation index (AIx), which reflects arterial stiffness, were calculated using the single-point method via the Mobil-O-Graph® ARCsolver algorithm. LVM was obtained by echocardiography. Plasma NT-proBNP was measured by electrochemiluminescence. The patients were divided into two groups according to the median eGFR value (eGFRlow group values were higher in eGFRlow group compared with eGFRhigh group (pvalues were higher in eGFRlow group compared with eGFRhigh group (pPresent study showed that eGFR was independently associated with PWV and NT-proBNP values. Importantly, these findings may explain, in part, the increase in cardiovascular risk in with slightly impaired renal function.

  1. Assessing the kidney function parameters glomerular filtration rate and effective renal plasma flow with dynamic FDG-PET/MRI in healthy subjects.

    Science.gov (United States)

    Geist, Barbara K; Baltzer, Pascal; Fueger, Barbara; Hamboeck, Martina; Nakuz, Thomas; Papp, Laszlo; Rasul, Sazan; Sundar, Lalith Kumar Shiyam; Hacker, Marcus; Staudenherz, Anton

    2018-05-09

    A method was developed to assess the kidney parameters glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) from 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) concentration behavior in kidneys, measured with positron emission tomography (PET) scans. Twenty-four healthy adult subjects prospectively underwent dynamic simultaneous PET/magnetic resonance imaging (MRI) examination. Time activity curves (TACs) were obtained from the dynamic PET series, with the guidance of MR information. Patlak analysis was performed to determine the GFR, and based on integrals, ERPF was calculated. Results were compared to intra-individually obtained reference values determined from venous blood samples. Total kidney GFR and ERPF as estimated by dynamic PET/MRI were highly correlated to their reference values (r = 0.88/p dynamic FDG PET/MRI scans in healthy kidneys. This has advantages for patients getting a routine scan, where additional examinations for kidney function estimation could be avoided. Further studies are required for transferring this PET/MRI method to PET/CT applications.

  2. Serum uric acid concentration is associated with early changes of glomerular filtration rate in patients with diabetes type 1 without increased albumin excretion.

    Science.gov (United States)

    Spaleniak, Sebastian; Korzeniewska-Dyl, Irmina; Moczulski, Dariusz

    2014-10-01

    The early loss of renal function in patients with type 1 diabetes may begin before proteinuria. Only 30% of patients with diabetes manifest overt proteinuria. According to the previous studies, increased urinary albumin excretion, which is considered a classic marker of progression of diabetic kidney disease, can regress to normal urine albumin excretion. The current studies conducted in patients with type 1 diabetes without increased urine albumin excretion showed that the uric acid concentration was an independent factor for the development of diabetic kidney disease. The aim of study was to assess the impact of uric acid concentration and to identify risk factors of the early glomerular filtration loss in patients with type 1 diabetes and normal urinary albumin excretion. 147 patients (61 women and 86 men) with type 1 diabetes without increased urine albumin excretion were analysed. GFR (gromerular filtration rate) was estimated based on the serum cystatin C concentration. Centile charts were used to determine the variation of uric acid concentration depending on GFR and gender. The mean value of the filtration rate for the study group was 117 ml/min/m2. The uric acid level above 90th percentile in relation to GFR was diagnosed in 8.2% of women and 0% of men, between 90th and 50th percentile in 44.3 % of women and 5.8% of men and below 50th percentile in 47.5% of women and 94.2% of men. Contrary to men in women higher serum acid concentration was strongly associated with higher glomerular filtration rate. Hyperfiltraion was diagnosed in 15 of women and 19 of men. The high normal uric acid concentration in women with type 1 diabetes might play a crucial role in development of hyperfiltration.

  3. Stent revascularization restores cortical blood flow and reverses tissue hypoxia in atherosclerotic renal artery stenosis but fails to reverse inflammatory pathways or glomerular filtration rate.

    Science.gov (United States)

    Saad, Ahmed; Herrmann, Sandra M S; Crane, John; Glockner, James F; McKusick, Michael A; Misra, Sanjay; Eirin, Alfonso; Ebrahimi, Behzad; Lerman, Lilach O; Textor, Stephen C

    2013-08-01

    Atherosclerotic renal artery stenosis (ARAS) is known to reduce renal blood flow, glomerular filtration rate (GFR) and amplify kidney hypoxia, but the relationships between these factors and tubulointerstitial injury in the poststenotic kidney are poorly understood. The purpose of this study was to examine the effect of renal revascularization in ARAS on renal tissue hypoxia and renal injury. Inpatient studies were performed in patients with ARAS (n=17; >60% occlusion) before and 3 months after stent revascularization, or in patients with essential hypertension (n=32), during fixed Na(+) intake and angiotensin converting enzyme/angiotensin receptors blockers Rx. Single kidney cortical, medullary perfusion, and renal blood flow were measured using multidetector computed tomography, and GFR by iothalamate clearance. Tissue deoxyhemoglobin levels (R(2)*) were measured by blood oxygen level-dependent MRI at 3T, as was fractional kidney hypoxia (percentage of axial area with R(2)*>30/s). In addition, we measured renal vein levels of neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α. Pre-stent single kidney renal blood flow, perfusion, and GFR were reduced in the poststenotic kidney. Renal vein neutrophil gelatinase-associated lipocalin, tumor necrosis factor-α, monocyte chemoattractant protein-1, and fractional hypoxia were higher in untreated ARAS than in essential hypertension. After stent revascularization, fractional hypoxia fell (Pblood flow, whereas GFR and neutrophil gelatinase-associated lipocalin, monocyte chemoattractant protein-1, and tumor necrosis factor-α remained unchanged. These data demonstrate that despite reversal of renal hypoxia and partial restoration of renal blood flow after revascularization, inflammatory cytokines and injury biomarkers remained elevated and GFR failed to recover in ARAS. Restoration of vessel patency alone failed to reverse tubulointerstitial damage and partly

  4. Glomerular filtration rate equations overestimate creatinine clearance in older individuals enrolled in the Baltimore Longitudinal Study on Aging: impact on renal drug dosing.

    Science.gov (United States)

    Dowling, Thomas C; Wang, En-Shih; Ferrucci, Luigi; Sorkin, John D

    2013-09-01

    To evaluate the performance of kidney function estimation equations and to determine the frequency of drug dose discordance in an older population. Cross-sectional analysis of data from community-dwelling volunteers randomly selected from the Baltimore Longitudinal Study of Aging from January 1, 2005, to December 31, 2010. A total of 269 men and women with a mean ± SD age of 81 ± 6 years, mean serum creatinine concentration (Scr ) of 1.1 ± 0.4 mg/dl, and mean 24-hour measured creatinine clearance (mClcr ) of 53 ± 13 ml/minute. Kidney function was estimated by using the following equations: Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). The performance of each equation was assessed by measuring bias and precision relative to mClcr . Dose calculation errors (discordance) were determined for 10 drugs requiring renal dosage adjustments to avoid toxicity when compared with the dosages approved by the Food and Drug Administration. The CG equation was the least biased estimate of mClcr . The MDRD and CKD-EPI equations were significantly positively biased compared with CG (mean ± SD 34 ± 20% and 22 ± 15%, respectively, prenal impairment. Thus equations estimating glomerular filtration rate should not be substituted in place of the CG equation in older adults for the purpose of renal dosage adjustments. In addition, the common practice of rounding or replacing low Scr values with an arbitrary value of 1.0 mg/dl for use in the CG equation should be avoided. Additional studies that evaluate alternative eGFR equations in the older populations that incorporate pharmacokinetic and pharmacodynamic outcomes measures are needed. © 2013 Pharmacotherapy Publications, Inc.

  5. Arterial wave reflections and kidney function decline among persons with preserved estimated glomerular filtration rate: the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Hsu, Jeffrey J; Katz, Ronit; Chirinos, Julio A; Jacobs, David R; Duprez, Daniel A; Peralta, Carmen A

    2016-05-01

    Differences in arterial wave reflections have been associated with increased risk for heart failure and mortality. Whether these measures are also associated with kidney function decline is not well established. Reflection magnitude (RM, defined as the ratio of the backward wave [Pb] to that of the forward wave [Pf]), augmentation index (AIx), and pulse pressure amplification (PPA) were derived from radial tonometry measures among 5232 participants free of cardiovascular disease who were enrolled in the Multiethnic Study of Atherosclerosis. Kidney function was estimated by creatinine and cystatin C measurements, as well as albumin-to-creatinine ratio. We evaluated the associations of Pb, Pf, RM, AIx, and PPA with annualized estimated glomerular filtration rate (eGFR) change and rapid kidney function decline over 5 years, using generalized linear mixed models and logistic regression, respectively. Of the study participants, 48% were male, mean age was 62 years, mean eGFR and median albumin-to-creatinine ratio at baseline were 84 mL/min/1.73 m(2) and 5.3 mg/g, respectively. In demographically adjusted models, both Pb and Pf had similarly strong associations with kidney function decline; compared to those in the lowest tertiles, the persons in the highest tertiles of Pb and Pf had a 1.01 and 0.99 mL/min/1.73 m(2)/year faster eGFR decline, respectively (P function decline. In conclusion, the reflected and forward wave components were similarly associated with kidney function decline, and these associations were explained by differences in systolic blood pressure. Copyright © 2016 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  6. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1982-01-01

    Significant developments in high-efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include (1) factory (bench) and in-place test methods, (2) new developments in paper and filter unit construction methods, (3) vented containment air cleaning systems for liquid-metal fast breeder reactors and light-water-moderated reactors, and (4) decontamination of off-gases from nuclear waste volume-reduction processes. Standards development has been vigorously pursued during this period, but advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of high-efficiency particulate air filters instead of those which have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge

  7. Aerosol filtration

    International Nuclear Information System (INIS)

    First, M.W.; Gilbert, H.

    1981-01-01

    Significant developments in high efficiency filtration for nuclear applications are reviewed for the period 1968 to 1980. Topics of special interest include factory (bench) and in-place test methods, new developments in paper and filter unit construction methods, vented containment air cleaning systems for LMFBR and light water moderated reactors, and decontamination of offgases from nuclear waste volume reduction processes. It is noted that standards development has been vigorously pursued during this period but that advances in filtration theory have been few. One of the significant changes likely to occur in the immediate future is adoption of the European style of HEPA filters for those that have been in service for the past three decades to obtain the benefits of having almost twice as much filter paper in the same filter cartridge. 71 references

  8. Glomerular filtration rate, cardiovascular risk factors and insulin resistance Filtrado glomerular, riesgo cardiovascular y resistencia a la insulina

    Directory of Open Access Journals (Sweden)

    Martín R. Salazar

    2009-10-01

    Full Text Available The aim of this paper was to study the estimated glomerular filtration rate (eGFR, its changes with age, and its association with systolic blood pressure (SBP and diastolic BP (DBP, indicators of obesity, dyslipemia, insulin resistance and inflammation on a random population sample. BP, weight, size and waist circumference (WC were recorded at home. Fasting morning blood samples were analysed. The eGFR was calculated with MDRD (eGFR-MDRD, Cockroft-Gault (eGFR-CG adjusted to 1.73 m² and reciprocal of serum creatinine (100/serum cretinine. A total of 1016 individuals, 722 females (41.97 ± 0.66 years old and 294 males (42.06 ± 0.99 years old, completed the laboratory tests. The mean of 100/Scr was 115.13 ± 0.60 (dl/mg, the mean eGFR-CG was 98.48 ± 0.82 ml/min/1.73 m²; the mean eGFR-MDRD was 85.15 ± 0.58 ml/min/1.73 m². The eGFR-MDRD decreased with age and with the number of risk factors in both sexes. The eGFR-MDRD El objetivo fue evaluar en una muestra poblacional aleatoria el filtrado glomerular estimado (FGe, sus cambios con la edad y su asociación con presión arterial sistólica (PAS y diastólica (PAD, indicadores de obesidad, dislipemia, resistencia a la insulina e inflamación. En cada domicilio fueron medidos presión arterial, peso y talla y perímetro de la cintura (PC. Se analizaron muestras de sangre en ayunas y fue calculado el FGe usando las fórmulas de MDRD (FGe-MDRD y Cockroft-Gault (FGe-CG ajustado a 1.73 m², y la inversa de la creatinina sérica (100/CrS. Completaron el protocolo de laboratorio 1016 sujetos, 722 mujeres (41.97 ± 0.66 años y 294 varones (42.06 ± 0.99 años. La media de 100/Crs fue 115.13 ± 0.60 (dl/mg, la del FGe-CG 98.48 ± 0.82 ml/min/1.73 m² y la del FGe-MDRD 85.15 ± 0.58 ml/min/1.73 m² (CI 95% 84.00-86.29. El FGe-MDRD disminuyó con la edad y con el número de factores de riesgo cardiovascular en ambos sexos. La prevalecencia ajustada de FGe-MDRD < 60 ml/min/1.73 m² fue 6.2 por 100

  9. Enzymatic creatinine assays allow estimation of glomerular filtration rate in stages 1 and 2 chronic kidney disease using CKD-EPI equation.

    Science.gov (United States)

    Kuster, Nils; Cristol, Jean-Paul; Cavalier, Etienne; Bargnoux, Anne-Sophie; Halimi, Jean-Michel; Froissart, Marc; Piéroni, Laurence; Delanaye, Pierre

    2014-01-20

    The National Kidney Disease Education Program group demonstrated that MDRD equation is sensitive to creatinine measurement error, particularly at higher glomerular filtration rates. Thus, MDRD-based eGFR above 60 mL/min/1.73 m² should not be reported numerically. However, little is known about the impact of analytical error on CKD-EPI-based estimates. This study aimed at assessing the impact of analytical characteristics (bias and imprecision) of 12 enzymatic and 4 compensated Jaffe previously characterized creatinine assays on MDRD and CKD-EPI eGFR. In a simulation study, the impact of analytical error was assessed on a hospital population of 24084 patients. Ability using each assay to correctly classify patients according to chronic kidney disease (CKD) stages was evaluated. For eGFR between 60 and 90 mL/min/1.73 m², both equations were sensitive to analytical error. Compensated Jaffe assays displayed high bias in this range and led to poorer sensitivity/specificity for classification according to CKD stages than enzymatic assays. As compared to MDRD equation, CKD-EPI equation decreases impact of analytical error in creatinine measurement above 90 mL/min/1.73 m². Compensated Jaffe creatinine assays lead to important errors in eGFR and should be avoided. Accurate enzymatic assays allow estimation of eGFR until 90 mL/min/1.73 m² with MDRD and 120 mL/min/1.73 m² with CKD-EPI equation. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Filtration behaviors of rod-shaped bacterial broths in unsteady-state phase of cross-flow filtration

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T.; Usui, K.; Koda, K.; Nakanishi, K. [Okayama University, Okayama (Japan). Faculty of Engineering

    1996-12-20

    Filtration behaviors in the unsteady-state phase of crossflow filtration of broths of Bacillus subtilis, Escherichia coli, and Lactobacillus delbrueckii, which are rod-shaped, were studied from the viewpoint of the changes in the specific resistance and in the structure of the microbial cake formed on the membrane surface. The permeation flux followed the cake filtration law at the initial stage of the crossflow filtration of the broths of B. subtilis and E. coli, where the cells deposited randomly on the membrane. In the case of the crossflow filtration of a L. delbrueckii broth, the period of random deposition was shorter. The specific resistance for the cake formed at the initial stage agreed with that measured in dead-end filtration. Then, the specific resistance started to increase in comparison with that measured in dead-end filtration due to shear-induced arrangement of the cells. The extent of the increase in specific resistance became higher and the time taken to start the cell arrangement became shorter with increasing circulation flow rate. The increase in specific resistance due to the shear-induced arrangement was more appreciable in the crossflow filtration of the broth of L. delbrueckii than that of B. subtilis and E. coli. The average permeation flux was increased considerably by applying periodical backwashing with appropriate time intervals. The permeation flux was well predicted by the cake filtration law, since the cells deposited in a way similar to that for dead-end filtration during a sufficiently short period of crossflow filtration in a backwashing mode. 21 refs., 11 figs.

  11. Determination of the best method to estimate glomerular filtration rate from serum creatinine in adult patients with sickle cell disease: a prospective observational cohort study

    Directory of Open Access Journals (Sweden)

    Arlet Jean-Benoît

    2012-08-01

    Full Text Available Abstract Background Sickle cell disease (SCD leads to tissue hypoxia resulting in chronic organ dysfunction including SCD associated nephropathy. The goal of our study was to determine the best equation to estimate glomerular filtration rate (GFR in SCD adult patients. Methods We conducted a prospective observational cohort study. Since 2007, all adult SCD patients in steady state, followed in two medical departments, have had their GFR measured using iohexol plasma clearance (gold standard. The Cockcroft-Gault, MDRD-v4, CKP-EPI and finally, MDRD and CKD-EPI equations without adjustment for ethnicity were tested to estimate GFR from serum creatinine. Estimated GFRs were compared to measured GFRs according to the graphical Bland and Altman method. Results Sixty-four SCD patients (16 men, median age 27.5 years [range 18.0-67.5], 41 with SS-genotype were studied. They were Sub-Saharan Africa and French West Indies natives and predominantly lean (median body mass index: 22 kg/m2 [16-33]. Hyperfiltration (defined as measured GFR >110 mL/min/1.73 m2 was detected in 53.1% of patients. Urinary albumin/creatinine ratio was higher in patients with hyperfiltration than in patients with normal GFR (4.05 mg/mmol [0.14-60] versus 0.4 mg/mmol [0.7-81], p = 0.01. The CKD-EPI equation without adjustment for ethnicity had both the lowest bias and the greatest precision. Differences between estimated GFRs using the CKP-EPI equation and measured GFRs decreased with increasing GFR values, whereas it increased with the Cockcroft-Gault and MDRD-v4 equations. Conclusions We confirm that SCD patients have a high rate of glomerular hyperfiltration, which is frequently associated with microalbuminuria or macroalbuminuria. In non-Afro-American SCD patients, the best method for estimating GFR from serum creatinine is the CKD-EPI equation without adjustment for ethnicity. This equation is particularly accurate to estimate high GFR values, including glomerular

  12. Evaluation of the effects of the metals Cd, Cr, Pb and their mixture on the filtration and oxygen consumption rates in catarina scallop, Argopecten ventricosus juveniles.

    Science.gov (United States)

    Sobrino-Figueroa, Alma S; Cáceres-Martinez, Carlos

    2014-01-01

    In this work, we evaluated the effect of sublethal concentrations ( LC25, LC10 and LC5) of cadmium, chromium, lead, and their mixture on the filtration rate and oxygen consumption rate of Catarina scallop, Argopecten ventricosus (Sowerby, 1842), juveniles, in order to evaluate the use of these biomarkers as a reliable tool in environmental monitoring studies, because these metals have been found at high levels in water and sediments in the Mexican Pacific systems. An inverse dose-response relationship was observed when metal concentration and exposure time increased, the filtration rate and oxygen consumption rate reduced. The physiological responses evaluated in this study were sufficiently sensitive to detect alterations in the organisms at 0.014 mg l(-1) Cd, 0.311 mg l(-1) Cr, 0.125 mg l(-1) Pb and 0.05 mg l(-1) Cd + Cr + Pb at 24 and 72 hrs. Cd showed the most drastic effect. The Catarina scallop juveniles were more sensitive to Cd, Cr and Pb as compared to other bivalves. The biomarkers evaluated are a reliable tool to carry out environmental monitoring studies.

  13. Rotating Ceramic Water Filter Discs System for Water Filtration

    Directory of Open Access Journals (Sweden)

    Riyadh Z. Al Zubaidy

    2017-04-01

    Full Text Available This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water. The filtration system was designed with two rotating interfered modules of these filters. Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs. The average measured hydraulic conductivity of the first module was 13.7mm/day and that for the second module was 50mm/day. Results showed that the water filtration system can be operated continuously with a constant flow rate and the filtration process was controlled by a skin thin layer of rejected materials. The ceramic water filters of both filtration modules have high removal efficiency of total suspended solids up to 100% and of turbidity up to 99.94%.

  14. The modified CKD-EPI equation may be not more accurate than CKD-EPI equation in determining glomerular filtration rate in Chinese patients with chronic kidney disease.

    Science.gov (United States)

    Xie, Peng; Huang, Jian-Min; Li, Ying; Liu, Huai-Jun; Qu, Yan

    2017-06-01

    To investigate the application of the new modified Chronic Kidney Disease Epidemiology Collaboration (mCKD-EPI) equation developed by Liu for the measurement of glomerular filtration rate (GFR) in Chinese patients with chronic kidney disease (CKD) and to evaluate whether this modified form is more accurate than the original one in clinical practice. GFR was determined simultaneously by 3 methods: (a) 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) dual plasma sample clearance method (mGFR), which was used as the reference standard; (b) CKD-EPI equation (eGFRckdepi); (c) modified CKD-EPI equation (eGFRmodified). Concordance correlation and Passing-Bablok regression were used to compare the validity of eGFRckdepi and eGFRmodified. Bias, precision and accuracy were compared to identify which equation showed the better performance in determining GFR. A total of 170 patients were enrolled. Both eGFRckdepi and eGFRmodified correlated well with mGFR (concordance correlation coefficient 0.90 and 0.74, respectively) and the Passing-Bablok regression equation of eGFRckdepi and eGFRmodified against mGFR was mGFR = 0.37 + 1.04 eGFRckdepi and -49.25 + 1.74 eGFRmodified, respectively. In terms of bias, precision and 30 % accuracy, eGFRmodified showed a worse performance compared to eGFRckdepi, in the whole cohort. The new modified CKD-EPI equation cannot replace the original CKD-EPI equation in determining GFR in Chinese patients with CKD.

  15. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  16. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  17. Abnormal glomerular filtration rate in children, adolescents and young adults starts below 75 mL/min/1.73 m(2).

    Science.gov (United States)

    Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre

    2015-05-01

    The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.

  18. RENAL HEMODYNAMICS AND GLOMERULAR FILTRATION RATE IN MEN AND WOMEN WITH ARTERIAL HYPERTENSION AT THE AGE OF 40-60 YEARS

    OpenAIRE

    I. G. Fomina; A. E. Bragina; N. E. Gaydamakina; J. N. Salimzhanova

    2015-01-01

    Aim. To study parameters of a renal hemodynamic and the general glomerular filtration rate (GGFR) and their correlations with cardiovascular risk factors (RF) in patient with arterial hypertension (AH).Material and methods. 102 patients with AH (35 men and 67 women of 40-60 y.o.) were involved in the study. 20 persons (10 men and 10 women) with normal blood pressure (BP) were included in control group. Dynamic renal angioscintigraphy was used for an estimation of a renal hemodynamic and GGFR....

  19. Over-estimation of glomerular filtration rate by single injection [51Cr]EDTA plasma clearance determination in patients with ascites

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Brøchner-Mortensen, J; Malchow-Møller, A

    1980-01-01

    The total plasma (Clt) and the renal plasma (Clr) clearances of [51Cr]EDTA were determined simultaneously in nine patients with ascites due to liver cirrhosis. Clt (mean 78 ml/min, range 34-115 ml/min) was significantly higher than Clr (mean 52 ml/min, range 13-96 ml/min, P ... fluid-plasma activity ratio of [51Cr]EDTA increased throughout the investigation period (5h). The results suggest that [51Cr]EDTA equilibrates slowly with the peritoneal space which indicates that Clt will over-estimate the glomerular filtration rate by approximately 20 ml/min in patients with ascites...

  20. Is the Chronic Kidney Disease Epidemiology Collaboration creatinine–cystatin C equation useful for glomerular filtration rate estimation in the elderly?

    Directory of Open Access Journals (Sweden)

    Liu X

    2013-10-01

    Full Text Available Xun Liu,1,2,* Huijuan Ma,1,* Hui Huang,3 Cheng Wang,1 Hua Tang,1 Ming Li,1 Yanni Wang,1 Tanqi Lou1 1Division of Nephrology, Department of Internal Medicine, The Third Affiliated Hospital of Sun Yat-sen University, 2College of Biology Engineering, South China University of Technology, 3Department of Cardiology, Sun Yat-sen Memorial Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China*These authors contributed equally to the paperBackground: We aimed to evaluate the performance of the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI creatinine–cystatin C equation in a cohort of elderly Chinese participants.Materials and methods: Glomerular filtration rate (GFR was measured in 431 elderly Chinese participants by the technetium-99m diethylene-triamine-penta-acetic acid (99mTc-DTPA renal dynamic imaging method, and was calibrated equally to the dual plasma sample 99mTc-DTPA-GFR. Performance of the CKD-EPI creatinine–cystatin C equation was compared with the Cockroft–Gault equation, the re-expressed 4-variable Modification of Diet in Renal Disease (MDRD equation, and the CKD-EPI creatinine equation.Results: Although the bias of the CKD-EPI creatinine–cystatin C equation was greater than with the other equations (median difference, 5.7 mL/minute/1.73 m2 versus a range from 0.4–2.5 mL/minute/1.73 m2; P<0.001 for all, the precision was improved with the CKD-EPI creatinine–cystatin C equation (interquartile range for the difference, 19.5 mL/minute/1.73 m2 versus a range from 23.0–23.6 mL/minute/1.73 m2; P<0.001 for all comparisons, leading to slight improvement in accuracy (median absolute difference, 10.5 mL/minute/1.73 m2 versus 12.2 and 11.4 mL/minute/1.73 m2 for the Cockcroft–Gault equation and the re-expressed 4-variable MDRD equation, P=0.04 for both; 11.6 mL/minute/1.73 m2 for the CKD-EPI creatinine equation, P=0.11, as the optimal scores of performance (6.0 versus a range from 1.0–2.0 for the other

  1. Validity of Serum Cystatin C as an Early and Accurate Marker of Glomerular Filtration Rate in type 1 Diabetes Mellitus Patients

    International Nuclear Information System (INIS)

    Fathy, H.A.; Fathy, M.A.

    2017-01-01

    The present study aims at exploring the clinical validity of measuring cystatin C for the early and accurate assessment of GFR (as compared to measuring serum creatinine or β2 microglobulin) in patients suffering from type 1 diabetes mellitus who are at risk of developing diabetic nephropathy as well as those who have already developed the condition. This study included 80 subjects who were further subdivided into two groups: Control group (1) which comprised 20 healthy age and sex matched children. Patient group (2) comprised 60 patients of both sexes properly diagnosed with type 1 diabetes. The patients were further subdivided into 3 subgroups according albumin levels in their 24 hour urine : Group 2a: 20 patients who were considered normo-albumin uric. Group 2b: 20 patients who were considered micro-albumin uric. Group 2c: 20 patients who were considered macro - albumin uric. All subjects were subjected to the estimation of serum creatinine level as well as serum β2 microglobulin and serum cystatin C levels. They were also subjected to Isotope renogram using "9"9"mTc- diethylene triamine pentaacetic acid (DTPA) single injection technique for accurate measurement of glomerular filtration rate (GFR). A positive correlation was observed between each of serum creatinine, β2 microglobulin, cystatin C with albumin in 24 hr urine in all the patient subgroups and this correlation was highly significant. However, the correlation between serum cystatin C levels in the diabetic patients and albumin in 24 hr urine was higher than that observed for either serum creatinine or serum β2 microglobulin. Cystatin C had the highest negative correlation with GFR (as measured by "9"9"mTc-DTPA clearance) compared to either serum creatinine or serum β 2 microglobulin in group II patients. It can be concluded that cystatin C could act as an early and accurate marker of GFR and renal function in patients with type 1 diabetes mellitus at risk of developing or who have already

  2. Influence of Iatrogenic Gaps, Cement Type, and Time on Microleakage of Cast Posts Using Spectrophotometer and Glucose Filtration Measurements.

    Science.gov (United States)

    Al-Madi, Ebtissam M; Al-Saleh, Samar A; Al-Khudairy, Reem I; Aba-Hussein, Taibah W

    2018-04-06

    To determine the influence of iatrogenic gaps, type of cement, and time on microleakage of cast posts using spectrophotometer and glucose filtration measurements. Forty-eight single-rooted teeth were divided into eight groups of six teeth each. Teeth were instrumented and obturated, and a cast post was fabricated. In addition to two control groups (positive and negative), a total of six groups were prepared: In four groups, an artificial 2- to 3-mm gap was created between post and residual gutta percha (GP), and two groups were prepared with intimate contact between post and residual GP. Posts were cemented with either zinc phosphate cement or resin cement. Leakage through the post after 1, 8, 14, and 20 days was measured using a glucose penetration model with two different reading methods. Mixed analysis of variance tests were performed to analyze the data. The presence of a gap between the apical end of the post and the most coronal portion of the GP remaining in the root canal after post space preparation increased microleakage significantly. However, microleakage was significantly less when the gap was refilled with GP compared to no gap. There was no difference in leakage between luting cements used. It was concluded that none of the cements were able to prevent microleakage. However, the addition of GP to residual GP did increase the sealing ability.

  3. Correlation of the glomerular filtration rate by the Gates scintigraphy method and by the creatinine purification in urine of 24 hours

    International Nuclear Information System (INIS)

    Gomez A, E.

    2003-01-01

    The kidney is an important organ that makes that exist equilibrium inside the organism. In it' s multiple functions, one that interests us to know is the glomerular filtration rate (GFR). To know this, exist laboratory and scintigraphy studies like the scintigraphy with technique of Gates and the creatinine purification in urine of 24 hours. The files of 44 patients were studied, which were clinically candidates to kidney donors healthy (25 women and 19 men) with ages that varied from the 18 years to the 54 years ( 35.1 years), with a weight of 43 kilograms to 94 kilograms (68.95 Kg) and with a corporal surface of 1.29 to 2.08 m 2 (1.70 m 2 ). These patients underwent study protocols with creatinine purification and with renal scintigraphy. The glomerular filtration rate obtained by creatinine purification varied from 51.9 ml/min. to 156 ml/min. and the GFR obtained by scintigraphy varied from 3.6 ml/min. to 155.2 ml/min. Once obtained the gathering of data the test of Student was applied to compare the averages of both distributions and the analysis of lineal regression to determine the coefficients of correlation of the complete group. (Author)

  4. Effect of the angle of apical resection on apical leakage, measured with a computerized fluid filtration device.

    Science.gov (United States)

    Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda

    2011-03-01

    We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an

  5. Measurement of the filtration coefficient (Kfc) in the lung of Gallus domesticus and the effects of increased microvascular permeability.

    Science.gov (United States)

    Weidner, W Jeffrey; Waddell, David S; Furlow, J David

    2006-08-01

    The filtration coefficient (Kfc) is a sensitive measure of microvascular hydraulic conductivity and has been reported for the alveolar lungs of many mammalian species, but not for the parabronchial avian lung. This study reports the Kfc in the isolated lungs of normal chickens and in the lungs of chickens given the edemogenic agents oleic acid (OA) or dimethyl amiloride (DMA). The control Kfc =0.04+/-0.01 ml min(-1) kPa(-1) g(-1). This parameter increased significantly following the administration of both OA (0.12+/-0.02 ml min(-1) kPa(-1) g(-1)) and DMA (0.07+/-0.01 ml min kPa(-1) g(-1)). As endothelial cadherins are thought to play a role in the dynamic response to acute lung injury, we utilized Western blot analysis to assess lung cadherin content and Northern blot analysis to assess pulmonary vascular endothelial (VE) cadherin expression following drug administration. Lung cadherin content decreases markedly following DMA, but not OA administration. VE cadherin expression increases as a result of DMA treatment, but is unchanged following OA. Our results suggest that the permeability characteristics of the avian lung are more closely consistent with those of the mammalian rather than the reptilian lung, and, that cadherins may play a significant role in the response to acute increases in avian pulmonary microvascular permeability.

  6. Association between serum bilirubin levels and decline in estimated glomerular filtration rate among patients with type 2 diabetes.

    Science.gov (United States)

    Wang, Jing; Li, Yaru; Han, Xu; Hu, Hua; Wang, Fei; Yu, Caizheng; Li, Xiulou; Yang, Kun; Yuan, Jing; Yao, Ping; Miao, Xiaoping; Wei, Sheng; Wang, Youjie; Chen, Weihong; Liang, Yuan; Zhang, Xiaomin; Guo, Huan; Pan, An; Yang, Handong; Wu, Tangchun; He, Meian

    2016-01-01

    Studies indicate that elevated serum total bilirubin (TBil) levels are associated with lower risk of diabetic kidney disease (DKD). Few studies examined the associations of direct bilirubin (DBil) and indirect bilirubin (IBil) with the development of DKD. Type 2 diabetes patients (n=2,958) with estimated glomerular filtration (eGFR)≥60mlmin(-1) 1.73m(-2) from the Dongfeng-Tongji cohort were selected and followed up for 5years. Development of DKD was defined as decline in eGFR≥30% during follow-up. Generalize linear model was used to assess the associations of bilirubin levels with DKD development. Compared with those in the first tertile of serum TBil, the relative risks (RRs) and 95% confidence intervals (CIs) of incident eGFR decline for tertile 2 to 3 were 0.83 (0.64-1.09) and 0.74 (0.56-0.98), Ptrend=0.04. The counterpart RRs (95% CIs) in IBil were 0.74 (0.57-0.97) and 0.75 (0.57-0.98), Ptrend=0.04. No significant associations were observed in DBil. Moreover, TBil and IBil interacted with smoking, the bilirubin-DKD associations were evident in ever smokers. Our findings suggest that elevation of serum TBil or IBil levels are independent protective factors for development of DKD, particularly in smokers. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Combining Cystatin C and Creatinine Yields a Reliable Glomerular Filtration Rate Estimation in Older Adults in Contrast to β-Trace Protein and β2-Microglobulin.

    Science.gov (United States)

    Werner, Karin; Pihlsgård, Mats; Elmståhl, Sölve; Legrand, Helen; Nyman, Ulf; Christensson, Anders

    2017-01-01

    The glomerular filtration rate (GFR) is the most important measure of kidney function and chronic kidney disease (CKD). This study aims to validate commonly used equations for estimated GFR (eGFR) based on creatinine (cr), cystatin C (cys), β-trace protein (BTP), and β2-microglobulin (B2M) in older adults. We conducted a validation study with 126 participants aged between 72 and 98 with a mean measured GFR (mGFR) by iohexol clearance of 54 mL/min/1.73 m2. The eGFR equations (CKD-Epidemiology collaboration [CKD-EPI], Berlin Initiative Study [BIS], Full Age Spectrum [FAS], Modification of Diet in Renal Disease [MDRD]cr, Caucasian-Asian-Pediatric-Adult [CAPA]cys, Lund-Malmö Revised [LM-REV]cr, and MEAN-LM-CAPAcr-cys), were assessed in terms of bias (median difference: eGFR-mGFR), precision (interquartile range of the differences), and accuracy (P30: percentage of estimates ±30% of mGFR). The equations were compared to a benchmark equation: CKD-EPIcr-cys. All cystatin C-based equations underestimated the GFR compared to mGFR, whereas bias was mixed for the equations based only on creatinine. Accuracy was the highest for CKD-EPIcr-cys (98%) and lowest for MDRD (82%). Below mGFR 45 mL/min/1.73 m2 only equations incorporating cystatin C reached P30 accuracy >90%. CKD-EPIcr-cys was not significantly more accurate than the other cystatin C-based equations. In contrast, CKD-EPIcr-cys was significantly more accurate than all creatinine-based equations except LM-REVcr. This study confirms that it is reasonable to use equations incorporating cystatin C and creatinine in older patients across a wide spectrum of GFR. However, the results call into question the use of creatinine alone below mGFR 45 mL/min/1.73 m2. B2M and BTP do not demonstrate additional value in eGFR determination in older adults. © 2017 S. Karger AG, Basel.

  8. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  9. Measured and estimated glomerular filtration rate (Part I. Adjustment to body surface area

    Directory of Open Access Journals (Sweden)

    Jaime Pérez Loredo

    2017-04-01

    The GFR is a necessary index for: diagnosis; follow-up of patients with renal injury; epidemiological controls; nephrotoxic drugs dose adjustment or renal elimination drugs; chronic renal disease stratification, etc.

  10. Filtration characteristics in membrane bioreactors

    NARCIS (Netherlands)

    Evenblij, H.

    2006-01-01

    Causes of and remedies for membrane fouling in Membrane Bioreactors for wastewater treatment are only poorly understood and described in scientific literature. A Filtration Characterisation Installation and a measurement protocol were developed with the aim of a) unequivocally determination and

  11. A genome-wide search for linkage of estimated glomerular filtration rate (eGFR in the Family Investigation of Nephropathy and Diabetes (FIND.

    Directory of Open Access Journals (Sweden)

    Farook Thameem

    Full Text Available Estimated glomerular filtration rate (eGFR, a measure of kidney function, is heritable, suggesting that genes influence renal function. Genes that influence eGFR have been identified through genome-wide association studies. However, family-based linkage approaches may identify loci that explain a larger proportion of the heritability. This study used genome-wide linkage and association scans to identify quantitative trait loci (QTL that influence eGFR.Genome-wide linkage and sparse association scans of eGFR were performed in families ascertained by probands with advanced diabetic nephropathy (DN from the multi-ethnic Family Investigation of Nephropathy and Diabetes (FIND study. This study included 954 African Americans (AA, 781 American Indians (AI, 614 European Americans (EA and 1,611 Mexican Americans (MA. A total of 3,960 FIND participants were genotyped for 6,000 single nucleotide polymorphisms (SNPs using the Illumina Linkage IVb panel. GFR was estimated by the Modification of Diet in Renal Disease (MDRD formula.The non-parametric linkage analysis, accounting for the effects of diabetes duration and BMI, identified the strongest evidence for linkage of eGFR on chromosome 20q11 (log of the odds [LOD] = 3.34; P = 4.4 × 10(-5 in MA and chromosome 15q12 (LOD = 2.84; P = 1.5 × 10(-4 in EA. In all subjects, the strongest linkage signal for eGFR was detected on chromosome 10p12 (P = 5.5 × 10(-4 at 44 cM near marker rs1339048. A subsequent association scan in both ancestry-specific groups and the entire population identified several SNPs significantly associated with eGFR across the genome.The present study describes the localization of QTL influencing eGFR on 20q11 in MA, 15q21 in EA and 10p12 in the combined ethnic groups participating in the FIND study. Identification of causal genes/variants influencing eGFR, within these linkage and association loci, will open new avenues for functional analyses and development of novel diagnostic markers

  12. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes

    Directory of Open Access Journals (Sweden)

    Magdalena Szopa

    2015-01-01

    Full Text Available Introduction. We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. Methods. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM, 70 with type 2 diabetes (T2DM, and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr and CKD-EPI cystatin C equation (eGFR-cys, respectively. Results. Cystatin C levels were lower (p<0.001 in the control (0.70±0.13 mg/L, HNF1A (0.75±0.21, and GCK (0.72±0.16 mg/L groups in comparison to those with either T1DM (0.87±0.15 mg/L or T2DM (0.9±0.23 mg/L. Moreover, eGFR-cys was higher than eGRF-cr in HNF1A-MODY, GCK-MODY, and the controls (p=0.004; p=0.003; p<0.0001. This corresponded to 8.9 mL/min/1.73 m2, 9.7 mL/min/1.73 m2, and 16.9 mL/min/1.73 m2 of difference. Additionally, T1DM patients had higher eGFR-cr than eGFR-cys (11.6 mL/min/1.73 m2; p=0.0004; no difference occurred in T2DM (p=0.91. Conclusions. We confirmed that eGFR-cys values in HNF1A-MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  13. A genome-wide search for linkage of estimated glomerular filtration rate (eGFR) in the Family Investigation of Nephropathy and Diabetes (FIND).

    Science.gov (United States)

    Thameem, Farook; Igo, Robert P; Freedman, Barry I; Langefeld, Carl; Hanson, Robert L; Schelling, Jeffrey R; Elston, Robert C; Duggirala, Ravindranath; Nicholas, Susanne B; Goddard, Katrina A B; Divers, Jasmin; Guo, Xiuqing; Ipp, Eli; Kimmel, Paul L; Meoni, Lucy A; Shah, Vallabh O; Smith, Michael W; Winkler, Cheryl A; Zager, Philip G; Knowler, William C; Nelson, Robert G; Pahl, Madeline V; Parekh, Rulan S; Kao, W H Linda; Rasooly, Rebekah S; Adler, Sharon G; Abboud, Hanna E; Iyengar, Sudha K; Sedor, John R

    2013-01-01

    Estimated glomerular filtration rate (eGFR), a measure of kidney function, is heritable, suggesting that genes influence renal function. Genes that influence eGFR have been identified through genome-wide association studies. However, family-based linkage approaches may identify loci that explain a larger proportion of the heritability. This study used genome-wide linkage and association scans to identify quantitative trait loci (QTL) that influence eGFR. Genome-wide linkage and sparse association scans of eGFR were performed in families ascertained by probands with advanced diabetic nephropathy (DN) from the multi-ethnic Family Investigation of Nephropathy and Diabetes (FIND) study. This study included 954 African Americans (AA), 781 American Indians (AI), 614 European Americans (EA) and 1,611 Mexican Americans (MA). A total of 3,960 FIND participants were genotyped for 6,000 single nucleotide polymorphisms (SNPs) using the Illumina Linkage IVb panel. GFR was estimated by the Modification of Diet in Renal Disease (MDRD) formula. The non-parametric linkage analysis, accounting for the effects of diabetes duration and BMI, identified the strongest evidence for linkage of eGFR on chromosome 20q11 (log of the odds [LOD] = 3.34; P = 4.4 × 10(-5)) in MA and chromosome 15q12 (LOD = 2.84; P = 1.5 × 10(-4)) in EA. In all subjects, the strongest linkage signal for eGFR was detected on chromosome 10p12 (P = 5.5 × 10(-4)) at 44 cM near marker rs1339048. A subsequent association scan in both ancestry-specific groups and the entire population identified several SNPs significantly associated with eGFR across the genome. The present study describes the localization of QTL influencing eGFR on 20q11 in MA, 15q21 in EA and 10p12 in the combined ethnic groups participating in the FIND study. Identification of causal genes/variants influencing eGFR, within these linkage and association loci, will open new avenues for functional analyses and development of novel diagnostic markers

  14. Accuracy of GFR estimation formula in determination of glomerular filtration rate in kidney donors: Comparison with 24 h urine creatinine clearance

    Directory of Open Access Journals (Sweden)

    Abdul Rauf Hafeez

    2016-01-01

    Full Text Available To determine the accuracy of estimated glomerular filtration rate (eGFR using the modification of diet in renal disease (MDRD, Cockcroft-Gault (CG, and chronic kidney disease epidemiology (CKD-EPI formulas in potential kidney donors compared with 24-h urine creatinine clearance, we studied 207 potential live kidney donors in our center. There were 126 (60.9% males and 81 (39.1% females. Male:female ratio was 1.6:1. The age of the donors ranged from 18-58 years, with mean age of 35.30 ± 9.23 years and most of the individuals were below 40 years of age. The body mass index (BMI was calculated and venous blood samples were obtained for the measurement of serum creatinine and every study participant was instructed to collect 24-h urine. GFR was calculated based on 24-h urine creatinine clearance and the formulas. The accuracy of GFR estimation formula was taken as positive if the GFR calculated by the formulas and urine creatinine clearance fell between 90-120 mL/min/1.73 m 2 . The accuracy of the MDRD formula was 48.8% and the CG formula was 41.5% whereas the accuracy of the CKD-EPI formula was 78.2%. The accuracy of the eGFR using the MDRD formula was significantly higher in males than females (57.9% vs. 33.3% P = 0.001, while there was no statistically significant difference in the eGFR between them in case of the use of the CG and the CKD-EPI formulas. BMI and obesity had no effect on the accuracy of eGFR by the use of the different formulas. The performance of GFR estimation formulas was sub optimal and these either underestimated and/or over-estimated the GFR in healthy subjects. CKD-EPI is closer to 24 -h urinary creatinine clearance in the calculation of eGFR. However, none of the eGFR formulas can be used in renal transplant donors because of their low accuracy, and 24-h urine creatinine clearance should be used for evaluation of the GFR in this population.

  15. Measurement of inertial confinement fusion reaction rate

    International Nuclear Information System (INIS)

    Peng Xiaoshi; Wang Feng; Tang Daorun; Liu Shenye; Huang Tianxuan; Liu Yonggang; Xu Tao; Chen Ming; Mei Yu

    2011-01-01

    Fusion reaction rate is an important parameter for measuring compression during the implosion in inertial confinement fusion experiment. We have developed a system for fusion reaction history measurement with high temporal resolution. The system is composed of plastic scintillator and nose cone, optical system and streak camera. We have applied this system on the SG-III prototype for fusion reaction rate measuring. For the first time, fusion reaction rate history have been measured for deuterium-tritium filled targets with neutrons yields about 10 10 . We have analyzed possible influence factor during fusion reaction rate measuring. It indicates that the instrument measures fusion reaction bang time at temporal resolutions as low as 30 ps.(authors)

  16. Glomerular filtration rate after alpha-radioimmunotherapy with 211At-MX35-F(ab')2: a long-term study of renal function in nude mice

    DEFF Research Database (Denmark)

    Back, T.; Haraldsson, B.; Hultborn, R

    2009-01-01

    of the glomerular filtration rate (GFR). The renal toxicity was evaluated at levels close to the dose limit for the bone marrow and well within the range for therapeutic efficacy on tumors. Astatinated MX35-F(ab')(2) monoclonal antibodies were administered intravenously to nude mice. Both non-tumor-bearing animals...... manifested late. Examination of the kidney sections showed histologic changes that were overall subdued. Following alpha-RIT with (211)At-MX35-F(ab')(2) at levels close to the dose limit of severe myelotoxicity, the effects found on renal function were relatively small, with only minor to moderate reductions...... in GFR. These results suggest that a mean absorbed dose to the kidneys of approximately 10 Gy is acceptable, and that the kidneys would not be the primary dose-limiting organ in systemic alpha-RIT when using (211)At-MX35-F(ab')(2) Udgivelsesdato: 2009/12...

  17. A precise evaluation of glomerular filtration rate (GFR) in two plasma samples following a single administration of 57Co-B12 vitamin

    International Nuclear Information System (INIS)

    Camargo, E.E.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E.; Papaleo Netto, M.; Carvalho, N.

    1974-01-01

    Through a logarithmic regression performed with the contings of 4 plasma samples withdrawn at 20,40,60 and 80 minutes after a venous injection of vitamin B 12 - 57 Co, the glomerular filtration-rate(GFR) in 11 patients, performing simultaneously the same study with EDTA- 51 Cr in 3 of them, is evaluated. The values obtained through the regression straight line are compared with those given by only 2 points, in the 6 possible combinations: 20 and 40 minutes, 20 and 60 minutes, 20 and 80 minutes, 40 and 60 minutes, 40 and 80 minutes, 60 and 80 minutes. The pair of points obtained at 20 and 80 minutes determined the straight line most similar to the logarithmic regression and as a simplification of the method, the withdraw of only 2 plasma samples, at and 80 minutes after a single injection of vitamin B 12 -57 Co is proposed [pt

  18. An acute fall in estimated glomerular filtration rate during treatment with losartan predicts a slower decrease in long-term renal function

    DEFF Research Database (Denmark)

    Holtkamp, Frank A; de Zeeuw, Dick; Thomas, Merlin C

    2011-01-01

    initial fall in eGFR had a significant lower long-term eGFR slope compared to those with a moderate fall or rise. This relationship was independent of other risk markers or change in risk markers for progression of renal disease such as blood pressure and albuminuria. Thus, the greater the acute fall in e......Intervention in the renin-angiotensin-aldosterone-system (RAAS) is associated with slowing the progressive loss of renal function. During initiation of therapy, however, there may be an acute fall in glomerular filtration rate (GFR). We tested whether this initial fall in GFR reflects a renal...... a significantly greater acute fall in estimated (eGFR) during the first 3 months compared to patients assigned to placebo, but a significantly slower long-term mean decline of eGFR thereafter. A large interindividual difference, however, was noticed in the acute eGFR change. When patients were divided...

  19. [Diagnostic ability of Chronic Kidney Disease Epidemiology Collaboration and Modification of Diet in Renal Disease-4 equations to estimate glomerular filtration rate in with multimorbidity patients].

    Science.gov (United States)

    Cabrerizo-García, José Luis; Díez-Manglano, Jesús; García-Arilla, Ernesto; Revillo-Pinilla, Paz; Ramón-Puertas, José; Sebastián-Royo, Mariano

    2015-01-06

    The Modification of Diet in Renal Disease (MDRD) equation is recommended by most scientific societies to calculate the estimated glomerular filtration rate (GFR). Recently the group Chronic Kidney Disease Epidemiology Collaboration (CKP-EPI) has published a new, more precise and accurate equation. We have analyzed its behavior in a group of polypathological patients (PP) and compared it with the classic MDRD-4.version Multicenter, observational, descriptive and transversal study. We calculated GFR by MDRD-4 and CKD-EPI in 425 PP. Each stage was assigned according to the GFR: 1:>90; 2: 60-89; 3: 30-59; 4: 15-29; and 5 renal insufficiency, especially in older women. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  20. Effects of body mass index and age on N-terminal pro brain natriuretic peptide are associated with glomerular filtration rate in chronic heart failure patients

    DEFF Research Database (Denmark)

    Schou, Morten; Gustafsson, Finn; Kistorp, Caroline N

    2007-01-01

    BACKGROUND: Obesity is a state characterized by glomerular hyperfiltration and age-related decreases in glomerular filtration rate (GFR). Body mass index (BMI), age, and GFR are associated with plasma concentrations of N-terminal pro-brain natriuretic peptide (NT-proBNP) in chronic heart failure...... (CHF) patients. We hypothesized that the effects of BMI and age on plasma concentrations of NT-proBNP are associated with GFR. METHODS: We obtained clinical data and laboratory test results from 345 CHF patients at the baseline visit in our heart failure clinic and examined the hypothesis using...... estimates for BMI (P = 0.3807) and age (P = 0.7238) changed markedly and became insignificant. In another model, after adjustment for GFR estimated by the 4-component Modification of Diet in Renal Disease formula (eGFR(MDRD)), the parameter estimates for age (P = 0.0674) changed markedly and became...

  1. Assessing glomerular filtration rate (GFR) in critically ill patients with acute kidney injury - true GFR versus urinary creatinine clearance and estimating equations

    Science.gov (United States)

    2013-01-01

    Introduction Estimation of kidney function in critically ill patients with acute kidney injury (AKI), is important for appropriate dosing of drugs and adjustment of therapeutic strategies, but challenging due to fluctuations in kidney function, creatinine metabolism and fluid balance. Data on the agreement between estimating and gold standard methods to assess glomerular filtration rate (GFR) in early AKI are lacking. We evaluated the agreement of urinary creatinine clearance (CrCl) and three commonly used estimating equations, the Cockcroft Gault (CG), the Modification of Diet in Renal Disease (MDRD) and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in comparison to GFR measured by the infusion clearance of chromium-ethylenediaminetetraacetic acid (51Cr-EDTA), in critically ill patients with early AKI after complicated cardiac surgery. Methods Thirty patients with early AKI were studied in the intensive care unit, 2 to 12 days after complicated cardiac surgery. The infusion clearance for 51Cr-EDTA obtained as a measure of GFR (GFR51Cr-EDTA) was calculated from the formula: GFR (mL/min/1.73m2) = (51Cr-EDTA infusion rate × 1.73)/(arterial 51Cr-EDTA × body surface area) and compared with the urinary CrCl and the estimated GFR (eGFR) from the three estimating equations. Urine was collected in two 30-minute periods to measure urine flow and urine creatinine. Urinary CrCl was calculated from the formula: CrCl (mL/min/1.73m2) = (urine volume × urine creatinine × 1.73)/(serum creatinine × 30 min × body surface area). Results The within-group error was lower for GFR51Cr-EDTA than the urinary CrCl method, 7.2% versus 55.0%. The between-method bias was 2.6, 11.6, 11.1 and 7.39 ml/min for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. The error was 103%, 68.7%, 67.7% and 68.0% for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. Conclusions The study

  2. The Effect of Cyanobacterial Biomass Enrichment by Centrifugation and GF/C Filtration on Subsequent Microcystin Measurement

    Directory of Open Access Journals (Sweden)

    Shelley Rogers

    2015-03-01

    Full Text Available Microcystins are cyclic peptides produced by multiple cyanobacterial genera. After accumulation in the liver of animals they inhibit eukaryotic serine/threonine protein phosphatases, causing liver disease or death. Accurate detection/quantification of microcystins is essential to ensure safe water resources and to enable research on this toxin. Previous methodological comparisons have focused on detection and extraction techniques, but have not investigated the commonly used biomass enrichment steps. These enrichment steps could modulate toxin production as recent studies have demonstrated that high cyanobacterial cell densities cause increased microcystin levels. In this study, three microcystin-producing strains were processed using no cell enrichment steps (by direct freezing at three temperatures and with biomass enrichment (by centrifugation or GF/C filtration. After extraction, microcystins were analyzed using liquid chromatography-tandem mass spectrometry. All processing methods tested, except GF/C filtration, resulted in comparable microcystin quotas for all strains. The low yields observed for the filtration samples were caused by adsorption of arginine-containing microcystins to the GF/C filters. Whilst biomass enrichment did not affect microcystin metabolism over the time-frame of normal sample processing, problems associated with GF/C filtration were identified. The most widely applicable processing method was direct freezing of samples as it could be utilized in both field and laboratory environments.

  3. Differential associations between glomerular filtration rate and duration of obesity depending on the presence or absence of left ventricular diastolic dysfunction.

    Science.gov (United States)

    Ybarra, Juan; Sánchez-Hernández, Joan; Vilallonga, Ramon; Romeo, June H

    2016-07-01

    A robust and consistent association between increasing body mass index (BMI) and chronic kidney disease (CKD) has been reported in several observational studies. Obesity remains the main preventable risk factor for CKD because it largely mediates diabetes and hypertension, the 2 most common etiologies for end-stage kidney disease (ESKD). Obesity is associated weakly with early stages of kidney disease but strongly with kidney progression to ESKD, even after adjustment for hypertension and diabetes. To assess the relationship between estimated glomerular filtration rate (eGFR) and trans-thoracic echocardiography left ventricular function parameters in a cohort of patients with obesity. Cross-sectional study involving 324 obese (BMI=44.0±2.2Kg/m(2)) apparently healthy asymptomatic patients with an eGFR >60ml/min/1.73m(2). Each patient underwent transthoracic echocardiography and a blood testing. The eGFR was addressed by the CKD-EPI formula. All patients had a normal systolic function whereas 24.5% disclosed diastolic dysfunction (DD). Hypertension and type 2 diabetes mellitus prevalence were 34.5% and 4.5% (respectively). All patients disclosed an eGFR >60ml/min while none of them disclosed hyperfiltration (eGFR >120ml/min). eGFR correlated inversely with BMI and the duration of obesity and positively with diastolic function parameters (Pobesity (PObesity and its duration are likely to impose hemodynamic changes affecting simultaneously both heart (diastolic dysfunction) and kidney (decreased glomerular filtration rate). Larger prospective studies are warranted. Copyright © 2016 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  4. An improved in-house lysis-filtration protocol for bacterial identification from positive blood culture bottles with high identification rates by MALDI-TOF MS.

    Science.gov (United States)

    Tsuchida, Sachio; Murata, Syota; Miyabe, Akiko; Satoh, Mamoru; Takiwaki, Masaki; Matsushita, Kazuyuki; Nomura, Fumio

    2018-05-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is now a well-established method for identification of microorganisms from positive blood cultures. Pretreatments to effectively remove non-bacterial proteins are a prerequisite for successful identification, and a variety of protocols have been reported. Although commercially available kits, mainly the Sepsityper Kit, are increasingly used, the identification rates reported often are not satisfactory, particularly for Gram-positive isolates. We developed a new, in-house lysis-filtration protocol and prospectively evaluated its performance compared to the Sepsityper kit. The in-house protocol consists of three simple steps: lysis by ammonium chloride, aspiration with a syringe fitted with a 0.45-μm membrane, and centrifugation to collect microbes. The novel protocol requires only 20 min. Performance of the in-house protocol was evaluated using a total of 117 monomicrobial cases of positive blood culture. Medium from blood culture bottles was pretreated by the in-house protocol or the commercial kit, and isolated cells were subjected to direct identification by mass spectrometry fingerprinting in parallel with conventional subculturing for reference identification. The overall MALDI-TOF MS-based identification rates with score > 1.7 and > 2.0 obtained using the in-house protocol were 99.2% and 85.5%, respectively, whereas those obtained using the Sepsityper Kit were 85.4% and 61.5%, respectively. For Gram-positive cases, the in-house protocol yielded scores >1.7 and > 2.0 at 98.5% and 76.1%, respectively, whereas the commercial kit yielded these scores at 76.1% and 43.3%, respectively. Although these are preliminary results, these values suggest that this easy lysis-filtration protocol deserves assessment in a larger-scale test. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Osculum dynamics and filtration activity in small single-osculum explants of the demosponge Halichondria panicea

    DEFF Research Database (Denmark)

    Kumala, Lars; Riisgård, Hans Ulrik; Canfield, Donald Eugene

    2017-01-01

    the clearance method. Osculum dynamics, as expressed by temporal variation of the OSA, including osculum contraction and expansion, correlated with variability in the explant filtration rate, and no water pumping was observed during periods of osculum closure. A linear relationship between filtration rate (FR......Contraction-inflation behavior, including the closure and opening of the exhalant opening (osculum), is common among sponges. This behavior may temporally affect filtration activity, making it difficult to study and understand sponge feeding biology. To examine the interplay between osculum...... dynamics and filtration activity, small (18 mm3) single-osculum explants of the demosponge Halichondria panicea were studied. Time-lapse video stereo-microscope recordings of the osculum cross-sectional area (OSA) were made simultaneously with measurements of the filtration rate (∼15°C, ∼20 PSU) using...

  6. Filtration of polydispersed colloids

    International Nuclear Information System (INIS)

    Nuttall, H.E.

    1988-01-01

    In this study, the dynamic microscopic form of the population balance model is applied to the problem of polydispersed particle capture in one spatial diffusion. This mathematical modeling approach can be applied to the difficult and potentially important problem of particulate (radiocolloid) transport in the groundwater surrounding a nuclear waste disposal site. To demonstrate the population balance methodology, the equations were developed and used to investigate transport and capture of polydispersed colloids in packed columns. Modeling simulations were compared to experimental column data. The multidimensional form of the population balance equation was used to analyze the transport and capture of polydispersed colloids. A numerical model was developed to describe transport of polydispersed colloids through a one-dimensional porous region. The effects of various size distributions were investigated in terms of capture efficiency. For simulating the column data, it was found by trial and error that as part of the population balance model a linear size dependent filtration function gave a good fit to the measured colloid concentration profile. The effects of constant versus size dependent filtration coefficients were compared and the differences illustrated by the calculated colloid profile within the column. Also observed from the model calculations was the dramatically changing liquid-phase colloid-size distribution which was plotted as a function of position down the column. This modeling approach was excellent for describing and understanding microscopic filtration in porous media

  7. Plasma NGAL and glomerular filtration rate in cardiac transplant recipients treated with standard or reduced calcineurin inhibitor levels

    DEFF Research Database (Denmark)

    Gustafsson, Finn; Gude, Einar; Sigurdardottir, Vilborg

    2014-01-01

    GFR) at baseline (R(2) = 0.21; p year (median [25-75 % percentiles]: ΔmGFR 5.5 [-0.5-11.5] vs -1 [-7-4] ml/min/1.73 m(2); p = 0.006). Baseline P-NGAL predicted mGFR after 1 year (R(2) = 0.18; p ...: P-NGAL was measured in 88 cardiac transplantation patients (median 5 years post-transplant) with renal dysfunction randomized to continuation of conventional calcineurin inhibitor-based immunosuppression or switching to an everolimus-based regimen. RESULTS: P-NGAL correlated with measured GFR (m...

  8. Glass dissolution rate measurement and calculation revisited

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Maxime, E-mail: maxime.fournier@cea.fr [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France); Ull, Aurélien; Nicoleau, Elodie [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France); Inagaki, Yaohiro [Department of Applied Quantum Physics & Nuclear Engineering, Kyushu University, Fukuoka, 819-0395 (Japan); Odorico, Michaël [ICSM-UMR5257 CEA/CNRS/UM2/ENSCM, Site de Marcoule, BP17171, F-30207, Bagnols sur Cèze (France); Frugier, Pierre; Gin, Stéphane [CEA, DEN, DTCD, SECM, F-30207, Bagnols sur Cèze (France)

    2016-08-01

    Aqueous dissolution rate measurements of nuclear glasses are a key step in the long-term behavior study of such waste forms. These rates are routinely normalized to the glass surface area in contact with solution, and experiments are very often carried out using crushed materials. Various methods have been implemented to determine the surface area of such glass powders, leading to differing values, with the notion of the reactive surface area of crushed glass remaining vague. In this study, around forty initial dissolution rate measurements were conducted following static and flow rate (SPFT, MCFT) measurement protocols at 90 °C, pH 10. The international reference glass (ISG), in the forms of powders with different particle sizes and polished monoliths, and soda-lime glass beads were examined. Although crushed glass grains clearly cannot be assimilated with spheres, it is when using the samples geometric surface (S{sub geo}) that the rates measured on powders are closest to those found for monoliths. Overestimation of the reactive surface when using the BET model (S{sub BET}) may be due to small physical features at the atomic scale—contributing to BET surface area but not to AFM surface area. Such features are very small compared with the thickness of water ingress in glass (a few hundred nanometers) and should not be considered in rate calculations. With a S{sub BET}/S{sub geo} ratio of 2.5 ± 0.2 for ISG powders, it is shown here that rates measured on powders and normalized to S{sub geo} should be divided by 1.3 and rates normalized to S{sub BET} should be multiplied by 1.9 in order to be compared with rates measured on a monolith. The use of glass beads indicates that the geometric surface gives a good estimation of glass reactive surface if sample geometry can be precisely described. Although data clearly shows the repeatability of measurements, results must be given with a high uncertainty of approximately ±25%. - Highlights: • Initial dissolution

  9. Filtration Behaviour and Fouling Mechanisms of Polysaccharides

    Directory of Open Access Journals (Sweden)

    Sondus Jamal

    2014-07-01

    Full Text Available This study investigated filtration behaviors of polysaccharides solutions, both alone and in mixture with proteins, in the short-time constant flux filtration with the focus on factors affecting the transmembrane pressure (TMP increase rate, the irreversible filtration resistance, and the membrane rejection behavior. The results showed that the TMP increase rates in the short-time constant flux filtration of alginate solutions were significantly affected by the calcium addition, alginate concentration, and flux. Although the addition of calcium resulted in a decrease in the TMP increase rate, it was found that the irreversible fouling developed during the filtration increased with the calcium addition, implying that the double-sided effect of calcium on membrane filtration and that the TMP increase rate observed in the filtration does not always reflect the irreversible membrane fouling development. It was also found that for the filtration of solutions containing mixed alginate and BSA, alginate exerted a dominant effect on the TMP increase rate and the membrane exhibited a reduced rejection to both alginate and BSA molecules compared to that in the filtration of the pure alginate or BSA.

  10. Effect of field exposure to 38-year-old residual petroleum hydrocarbons on growth, condition index, and filtration rate of the ribbed mussel, Geukensia demissa

    International Nuclear Information System (INIS)

    Culbertson, Jennifer B.; Valiela, Ivan; Olsen, Ylva S.; Reddy, Christopher M.

    2008-01-01

    In September 1969, the Florida barge spilled 700,000 L of No. 2 fuel oil into the salt marsh sediments of Wild Harbor, MA. Today a substantial amount, approximately 100 kg, of moderately degraded petroleum remains within the sediment and along eroding creek banks. The ribbed mussels, Geukensia demissa, which inhabit the salt marsh creek bank, are exposed to the spilled oil. Examination of short-term exposure was done with transplantation of G. demissa from a control site, Great Sippewissett marsh, into Wild Harbor. We also examined the effects of long-term exposure with transplantation of mussels from Wild Harbor into Great Sippewissett. Both the short- and long-term exposure transplants exhibited slower growth rates, shorter mean shell lengths, lower condition indices, and decreased filtration rates. The results add new knowledge about long-term consequences of spilled oil, a dimension that should be included when assessing oil-impacted areas and developing management plans designed to restore, rehabilitate, or replace impacted areas. - Mussels exposed to petroleum in transplant and field experiments exhibited significant long-term effects

  11. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method

    Energy Technology Data Exchange (ETDEWEB)

    You, Shan [Hebei North University, Department of Graduate, Zhangjiakou City, Hebei Province (China); Ma, XianWu; Zhang, ChangZhu; Li, Qiang [Qiqihar Chinese Medicine Hospital, Department of Radiology, Qigihar City, Heilongjiang Province (China); Shi, WenWei; Zhang, Jing; Yuan, XiaoDong [The 309th Hospital of Chinese People' s Liberation Army, Department of Radiology, Beijing (China)

    2018-03-15

    To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR. Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots. Paired difference between single-kidney CT-GFR (45.02 ± 13.91) and single-kidney Gates-GFR (51.21 ± 14.76) was 6.19 ± 5.63 ml/min, p<0.001, demonstrating 12.1% systematic underestimation with ±11.03 ml/min (±21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p<0.001). The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function. (orig.)

  12. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method

    International Nuclear Information System (INIS)

    You, Shan; Ma, XianWu; Zhang, ChangZhu; Li, Qiang; Shi, WenWei; Zhang, Jing; Yuan, XiaoDong

    2018-01-01

    To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR. Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots. Paired difference between single-kidney CT-GFR (45.02 ± 13.91) and single-kidney Gates-GFR (51.21 ± 14.76) was 6.19 ± 5.63 ml/min, p<0.001, demonstrating 12.1% systematic underestimation with ±11.03 ml/min (±21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p<0.001). The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function. (orig.)

  13. Evaluation of 99Tcm-DTPA glomerular filtration rate by the Gates method in patients with type 2 diabetes

    International Nuclear Information System (INIS)

    Yuan Jie; Zhang Guangming; Liu Congjin; Wang Yuankai; Zhu Huiqing; Kuai Dayu; Wu Xia; Hu Renming; Liu Xingdang

    2013-01-01

    Objective: To study the changes of GFR measured in different time intervals after the injection of 99 Tc m -DTPA and to evaluate the clinical value of GFR in patients with type 2 diabetes. Methods: Eleven healthy volunteers (6 males, 5 females; mean age (61.45±7.90) years, age range: 47-79 years) and 56 patients with type 2 diabetes (31 males, 25 females; mean age (60.98±6.96) years, age range: 45-75 years) were recruited. 99 Tc m -DTPA was used to measure GFR for all subjects. ROI was drawn at 2 and 3 min post-injection and GFR was calculated by Gates method. Two-sample t test and Pearson correlation analysis were performed with SPSS 15.0. Results: SCr ((84.90±14.38) μmol/L) was significantly correlated with GFR in patients with type 2 diabetes. There was negative correlation between SCr and GFR for both, left and right kidneys at 3 min post-injection (r=-0.652, -0.636, -0.470, all P≤0.001) and at 2 min post-injection (r=-0.599, -0.553, -0.529, all P<0.001). Total GFR, GFR for left kidney and GFR for right kidney at 3 min post-injection in diabetes group ((69.77 ± 11.00),(33.12 ± 5.74), (37.34 ± 9.81) ml/min) were lower than those in control group ((97.89±5.98), (46.60±4.91), (51.28±4.20) ml/min; t=-8.212, -7.233, -4.069, all P<0.001). Conclusions: To calculate the GFR of the patients with type 2 diabetes, 3 min post-injection is the optimal time. Measurement of GFR by 99 Tc m -DTPA is useful in early diagnosis of diabetic nephropathy. (authors)

  14. Risk Stratification by 24-Hour Ambulatory Blood Pressure and Estimated Glomerular Filtration Rate in 5322 Subjects From 11 Populations

    DEFF Research Database (Denmark)

    Boggia, José; Thijs, Lutgarde; Li, Yan

    2013-01-01

    subjects (median age, 51.8 years; 43.1% women) randomly recruited from 11 populations, who had baseline measurements of 24-hour ambulatory blood pressure (ABP(24)) and eGFR. We computed hazard ratios using multivariable-adjusted Cox regression. Median follow-up was 9.3 years. In fully adjusted models......, which included both ABP(24) and eGFR, ABP(24) predicted (P≤0.008) both total (513 deaths) and cardiovascular (206) mortality; eGFR only predicted cardiovascular mortality (P=0.012). Furthermore, ABP(24) predicted (P≤0.0056) fatal combined with nonfatal events as a result of all cardiovascular causes...... (555 events), cardiac disease (335 events), or stroke (218 events), whereas eGFR only predicted the composite cardiovascular end point and stroke (P≤0.035). The interaction terms between ABP(24) and eGFR were all nonsignificant (P≥0.082). For cardiovascular mortality, the composite cardiovascular end...

  15. HANARO core channel flow-rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heon Il; Chae, Hee Tae; Im, Don Soon; Kim, Seon Duk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    HANARO core consists of 23 hexagonal flow tubes and 16 cylindrical flow tubes. To get the core flow distribution, we used 6 flow-rate measuring dummy fuel assemblies (instrumented dummy fuel assemblies). The differential pressures were measured and converted to flow-rates using the predetermined relationship between AP and flow-rate for each instrumented dummy fuel assemblies. The flow-rate for the cylindrical flow channels shows +-7% relative errors and that for the hexagonal flow channels shows +-3.5% relative errors. Generally the flow-rates of outer core channels show smaller values compared to those of inner core. The channels near to the core inlet pipe and outlet pipes also show somewhat lower flow-rates. For the lower flow channels, the thermal margin was checked by considering complete linear power histories. From the experimental results, the gap flow-rate was estimated to be 49.4 kg/s (cf. design flow of 50 kg/s). 15 tabs., 9 figs., 10 refs. (Author) .new.

  16. Measurement of Biocolloid Collision Efficiencies for Granular Activated Carbon by Use of a Two-Layer Filtration Model

    Science.gov (United States)

    Paramonova, Ekaterina; Zerfoss, Erica L.; Logan, Bruce E.

    2006-01-01

    Point-of-use filters containing granular activated carbon (GAC) are an effective method for removing certain chemicals from water, but their ability to remove bacteria and viruses has been relatively untested. Collision efficiencies (α) were determined using clean-bed filtration theory for two bacteria (Raoutella terrigena 33257 and Escherichia coli 25922), a bacteriophage (MS2), and latex microspheres for four GAC samples. These GAC samples had particle size distributions that were bimodal, but only a single particle diameter can be used in the filtration equation. Therefore, consistent with previous reports, we used a particle diameter based on the smallest diameter of the particles (derived from the projected areas of 10% of the smallest particles). The bacterial collision efficiencies calculated using the filtration model were high (0.8 ≤ α ≤ 4.9), indicating that GAC was an effective capture material. Collision efficiencies greater than unity reflect an underestimation of the collision frequency, likely as a result of particle roughness and wide GAC size distributions. The collision efficiencies for microspheres (0.7 ≤ α ≤ 3.5) were similar to those obtained for bacteria, suggesting that the microspheres were a reasonable surrogate for the bacteria. The bacteriophage collision efficiencies ranged from ≥0.2 to ≤0.4. The predicted levels of removal for 1-cm-thick carbon beds ranged from 0.8 to 3 log for the bacteria and from 0.3 to 1.0 log for the phage. These tests demonstrated that GAC can be an effective material for removal of bacteria and phage and that GAC particle size is a more important factor than relative stickiness for effective particle removal. PMID:16885264

  17. Optimal equation for estimation of glomerular filtration rate in autosomal dominant polycystic kidney disease: influence of tolvaptan.

    Science.gov (United States)

    Yamaguchi, Tsuyoshi; Higashihara, Eiji; Okegawa, Takatsugu; Miyazaki, Isao; Nutahara, Kikuo

    2018-05-22

    The reliability of various equations for estimating the GFR in ADPKD patients and the influence of tolvaptan on the resulting estimates have not been examined when GFR is calculated on the basis of inulin clearance. We obtained baseline and on-tolvaptan measured GFRs (mGFRs), calculated on the basis of inulin clearance, in 114 ADPKD, and these mGFRs were compared with eGFRs calculated according to four basic equations: the MDRD, CKD-EPI, and JSN-CKDI equations and the Cockcroft-Gault formula, as well as the influence of tolvaptan and of inclusion of cystatin C on accuracy of the results. Accuracy of each of the seven total equations was evaluated on the basis of the percentage of eGFR values within mGFR ± 30% (P 30 ). mGFRs were distributed throughout CKD stages 1-5. Regardless of the CKD stage, P 30 s of the MDRD, CKD-EPI, and JSN-CKDI equations did not differ significantly between baseline values and on-tolvaptan values. In CKD 1-2 patients, P 30 of the CKD-EPI equation was 100.0%, whether or not the patient was on-tolvaptan. In CKD 3-5 patients, P 30 s of the MDRD, CKD-EPI, and JSN-CKDI equations were similar. For all four equations, regression coefficients and intercepts did not differ significantly between baseline and on-tolvaptan values, but accuracy of the Cockcroft-Gault formula was inferior to that of the other three equations. Incorporation of serum cystatin C reduced accuracy. The CKD-EPI equation is most reliable, regardless of the severity of CKD. Tolvaptain intake has minimal influence and cystatin C incorporation does not improve accuracy.

  18. Filtration of Sludge and Sodium Nonatitanate Solutions

    International Nuclear Information System (INIS)

    Poirier, M.R.

    2000-01-01

    The proposed facility designs for the ion exchange and solvent extraction flowsheets under development to treat high level waste at the Savannah River Site use crossflow filtration to remove entrained sludge and monosodium titanate (MST). Bench-scale and pilot-scale testing performed with simulated feed streams showed much lower filtration rates than desired for the process. This report documents an investigation of the impact on filtration of using Honeywell sodium nonatitanate (ST), rather than MST, for strontium and actinide removal

  19. The development of electro-membrane filtration for the isolation of bioactive peptides: the effect of membrane selection and operating parameters on the transport rate

    NARCIS (Netherlands)

    Bargeman, Gerrald; Koops, G.H.; Houwing, J.; Breebaart, I.; van der Horst, H.C.; Wessling, Matthias

    2002-01-01

    The ability to produce functional food ingredients from natural sources becomes increasingly attractive to the food industry. Antimicrobial (bioactive) ingredients, like peptides and proteins, can be isolated from hydrolysates with membrane filtration and/or chromatography. Electro-membrane

  20. Particle size distribution as a new measuring quantity in waste water filtration; Partikelgroessenverteilung als neue Messgroesse in der Abwasserfiltration

    Energy Technology Data Exchange (ETDEWEB)

    Herwig, V.; Tiehm, A.; Neis, U. [Technische Univ. Hamburg-Harburg, Hamburg (Germany). Arbeitsbereich Abwasserwirtschaft

    1999-07-01

    The transport and distribution of anthropogenous water constituents are closely related to the behaviour of suspended solids. At municipal sewage treatment plants the elimination of solids takes place as a rule through sedimentation in sedimentation tanks. Because of more stringent cleaning requirements, a chamber filter is frequently added downstream for further elimination of suspended solids. Only through the combination of sedimentation and chamber filtration is reliable retention of solids and associated pollutants or nutrients safeguarded. This work aims to gain better understanding of the processes in the filter through a methodically new approach. This will form the basis for optimized dimensioning and more economical operation of interconnected elimination of solids through sedimentation and filtration. (orig.) [German] Der Transport und die Verteilung anthropogener Wasserinhaltsstoffe steht in engem Zusammenhang mit dem Verhalten der suspendierten Feststoffen. Die Feststoffabtrennung erfolgt in kommunalen Klaeranlagen in der Regel durch Sedimentation in der Nachklaerung. Aufgrund verschaerfter Reinigungsanforderungen wird zur weitergehenden Entfernung der suspendierten Feststoffe haeufig ein Raumfilter nachgeschaltet. Erst durch die Kombination von Sedimentation/Raumfiltration wird ein sicherer Rueckhalt der Feststoffe und assoziierter Schad- sowie Naehrstoffe erreicht. Ziel dieser Arbeit ist es, mit einem methodisch neuen Ansatz zu einem besseren Verstaendnis der Prozesse im Raumfilter zu gelangen. Dieses bildet die Grundlage fuer die optimierte Bemessung und einen oekonomischeren Betrieb der Feststoffseparation im Verbund Nachklaerung/Raumfiltration. (orig.)

  1. Screening for decreased glomerular filtration rate and associated risk factors in a cohort of HIV-infected patients in a middle-income country.

    Directory of Open Access Journals (Sweden)

    Patrícia Santiago

    Full Text Available With the introduction of combined active antiretroviral therapy and the improved survival of HIV-infected patients, degenerative diseases and drug toxicity have emerged as long-term concerns. We studied the prevalence of decreased glomerular filtration rate (GFR and associated risk factors in a cohort of HIV-infected patients from a middle-income country. Our cross-sectional study included all adult patients who attended an urban outpatient clinic in 2008. GFR was estimated using the CKD-EPI equation. The prevalence ratio (PR of decreased GFR (defined as <60 mL/min/1.73 m(2 was estimated using generalizing linear models assuming a Poisson distribution. We analyzed data from 1,970 patients, of which 82.9% had been exposed to ART. A total of 249 patients (12.6% had a GFR between 60 and 89 mL/min/1.73 m(2, 3.1% had a GFR between 30 and 59, 0.3% had a GFR between 15 and 29, and 0.4% had a GFR <15. Decreased GFR was found in only 74 patients (3.8%. In the multivariate regression model, the factors that were independently associated with a GFR below 60 mL/min/1.73 m(2 were as follows: age ≥ 50 years (PR = 3.4; 95% CI: 1.7-6.8, diabetes (PR = 2.0; 95% CI: 1.2-3.4, hypertension (PR = 2.0; 95% CI: 1.3-3.2, current CD4+ cell count <350 cells/mm3 (PR = 2.1; 95% CI: 1.3-3.3, past exposure to tenofovir (PR = 4.7; 95% CI: 2.3-9.4 and past exposure to indinavir (PR =1.7; 95% CI: 1.0-2.8. As in high-income countries, CKD was the predominant form of kidney involvement among HIV-infected individuals in our setting. The risk factors associated with decreased glomerular filtration were broad and included virus-related factors as well as degenerative and nephrotoxic factors. Despite the potential for nephrotoxicity associated with some antiretroviral drugs, in the short-term, advanced chronic renal disease remains very rare.

  2. RENAL HEMODYNAMICS AND GLOMERULAR FILTRATION RATE IN MEN AND WOMEN WITH ARTERIAL HYPERTENSION AT THE AGE OF 40-60 YEARS

    Directory of Open Access Journals (Sweden)

    I. G. Fomina

    2015-12-01

    Full Text Available Aim. To study parameters of a renal hemodynamic and the general glomerular filtration rate (GGFR and their correlations with cardiovascular risk factors (RF in patient with arterial hypertension (AH.Material and methods. 102 patients with AH (35 men and 67 women of 40-60 y.o. were involved in the study. 20 persons (10 men and 10 women with normal blood pressure (BP were included in control group. Dynamic renal angioscintigraphy was used for an estimation of a renal hemodynamic and GGFR.Results. Hypertensive women had lower renal blood flow and GGFR than these in men (p<0,000. Renal hemodynamics and GGFR in men and women did not differ in control group. Positive correlation  r=0,61; p<0,05 between GGFR and a tobacco smoking was found in hypertensive men as well as negative correlation (r=-0,41; p<0,005 between GGFR and body mass index (BMI in women.Conclusion. Renal blood flow and GGFR are lower in hypertensive women than these in men. Positive correlation between GGFR and tobacco smoking and negative correlation between GGFR and BMI were found in men and women respectively.

  3. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Funama, Yoshinori

    2011-01-01

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 ± 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m 2 ) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 2 at baseline was high in patients with advanced age, CVD and DM and in patients without oncologic disease

  4. Comparison of the performance of the updated Schwartz, combined Schwartz and the Grubb glomerular filtration rate equations in a general pediatric population

    Directory of Open Access Journals (Sweden)

    Alaleh Gheissari

    2014-01-01

    Full Text Available To determine the performance of the updated Schwartz, combined Schwartz and Grubb glomerular filtration rate (GFR equations in a relatively large number of healthy children with no known renal disease, we studied 712 students aged between seven and 18 years from the Isfahan province of Iran by random cluster sampling between 2009 and 2010. Blood investigations included blood urea nitrogen, creatinine and cystatin C. For each participant, GFR was calculated based on the three equations. We used Bland-Altman plots and weighted kappa statistics to compare the performance of the study equations. The mean age of the children was 12.2 ± 2.4 years. A high concordance in estimating GFR (mean difference: 0 ± 12.7 mL/min/1.73 m 2 and a very good agreement in defining chronic kidney disease (CKD and non-CKD individuals (weighted kappa: 0.85; 95% confidence intervals: 0.69-1 were observed between the updated Schwartz and the combined Schwartz equations. Poor agreement was observed between the Grubb equation and two Schwartz equations in estimating GFR and defining CKD. There was no systematic deviation between the updated Schwartz and the combined Schwartz equations in children with normal renal function. The Grubb equation was highly inconsistent with both Schwartz equations in this population. We conclude that the updated Schwartz equation is simpler and more accessible than the combined Schwartz equation in daily clinical practice and CKD screening programs.

  5. Association Between Contrast Media Volume-Glomerular Filtration Rate Ratio and Contrast-Induced Acute Kidney Injury After Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Celik, Omer; Ozturk, Derya; Akin, Fatih; Ayca, Burak; Yalcın, Ahmet Arif; Erturk, Mehmet; Bıyık, Ismail; Ayaz, Ahmet; Akturk, Ibrahim Faruk; Enhos, Asım; Aslan, Serkan

    2015-07-01

    We hypothesized that contrast media volume-estimated glomerular filtration rate (CV-e-GFR) ratio may be a predictor of contrast media-induced acute kidney injury (CI-AKI). We investigated the associations between CV-e-GFR ratio and CI-AKI in 597 patients undergoing primary percutaneous coronary intervention (pPCI). An absolute ≥0.3 mg/dL increase in serum creatinine compared with baseline levels within 48 hours after the procedure was considered as CI-AKI; 78 (13.1%) of the 597 patients experienced CI-AKI. The amount of contrast during procedure was higher in the CI-AKI group than in those without CI-AKI (153 vs 135 mL, P = .003). The CV-e-GFR ratio was significantly higher in patients with CI-AKI than without (2.3 vs 1.5, P 2 (P < .001, OR = 5.917). In conclusion, CV-e-GFR ratio is significantly associated with CI-AKI after pPCI. © The Author(s) 2014.

  6. Soluble tumor necrosis factor receptor 1 is associated with diminished estimated glomerular filtration rate in colombian patients with type 2 diabetes.

    Science.gov (United States)

    Gómez-Banoy, Nicolás; Cuevas, Virginia; Higuita, Andrea; Aranzález, Luz Helena; Mockus, Ismena

    2016-07-01

    The tumor necrosis factor α (TNF-α) family of inflammatory molecules plays a crucial role in the pathogenesis of type 2 diabetes mellitus (DM2) complications. TNF-α soluble receptors 1 (sTNFR1) and 2 (sTNFR2) have been associated with chronic kidney disease in DM2 patients. This cross-sectional study intended to determine serum concentrations of sTNFR1 and sTNFR2 in Colombian patients and correlated them with various clinical variables, especially kidney function. 92 Colombian patients with DM2 were recruited. Anthropometric variables, glycemic control parameters, lipid profile and renal function were assessed for each patient. Levels of sTNFR1 and sTNFR2 were determined using ELISA. Patients were stratified in two groups according to reduced estimated glomerular filtration rate (eGFR) (studies should focus on social and genetic determinants of inflammation and their association with CKD in this ethnicity. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Experiences in integrated leak rate measurements

    International Nuclear Information System (INIS)

    Shirk, R.E.

    1982-01-01

    During a hypothetical design basis accident for nuclear power plants, the reactor containment system is relied upon to maintain radioactive exposure limits below acceptable limits. Integrated leak rate testing is a means of verifying that the leakage of radioactivity material from the reactor containment will be below allowable limits. Leakage rate computations are based on the ideal gas law. The absolute method of leakage rate testing utilizing mass point method of data analysis is recommended. Integrated leak rate testing data is obtained from pressure, drybulb temperature, dewpoint temperature, and flow measuring systems. Test data does not support the usual leakage (flow) - pressure square root relationship. The major source of potential leakage from the reactor containment is reactor containment isolation valves

  8. Glomerular filtration values obtained with 99mTc-DTPA v/s measurements of creatinine Clearance and calculation of the filtered glomerular using the Schwartz formula in a pediatric population

    International Nuclear Information System (INIS)

    Opazo, Claudio; Gutierrez, Elisa; Zamorano, Julio; Troncoso, TM

    2005-01-01

    We compare glomerular filtration rate by DTPA Renogram (DTPA-GFR) with creatinine clearance (CC) and Glomerular filtration rate from Schwartz formula (Schwartz-GFR). The need for using (DTPA-GFR) method raised from the practical difficulties in getting an accurate (CC) in pediatric population. From Sep-2001 to May-2005, 48 patients aged 1month to 18 years, underwent (DTPA-GFR) and (Schwartz-GFR). 18 had also (CC). Comparison were made among these measurements also accounting for age groups. We found a better correlation between (DTPA-GFR) and (CC) Pearson = 0,895. (Schwartz)/(CC) comparison showed a slightly lower correlation Pearson = 0,857. The worst correlation was found comparing (DTPA-GFR)/(Schwartz-GFR) in children < 3 yr Pearson = 0,560. As we found a better correlation between (DTPA-GFR)/(CC) than (DTPA-GFR)/(Schwartz-GFR), DTPA-GFR could be considered reliable method in evaluating renal function in children having difficulties to get a Creatinine Clearance (au)

  9. Problems in continuous dose rate measurement

    International Nuclear Information System (INIS)

    Yoshioka, Mitsuo

    1983-01-01

    The system of continuous dose rate measurement in Fukui Prefecture is described. A telemeter system was constructed in October, 1976, and it has been operated since 1977. Observation has been made at 11 observation stations in the Prefecture. In addition to the continuous measurement of dose rate by using NaI(T1)-DBM systems, the ionization chambers for high dose rate were installed, and also meteorological data have been collected. The detectors are covered with 1 mm thick aluminum designed so that the absorption of external radiation is kept as small as possible. To keep the environmental temperature of the detectors constant, constant temperature wind blow is made. With these consideration, the measurement of Xe-133 is possible, and the standard deviation of yearly dose is around 0.4 mR/Y. By measuring DBM transmission rate, the contribution of Xe-133, which comes from the exhaust pumps in power plants, can be detected. The problems of this system are as follows. First of all, the characteristics of the system must meet the purpose of dose monitoring. The system must detect the dose less than the target value to be achieved. The second is the selection of measuring systems to be set. The system is still not unified, and it is difficult to exchange data between different stations. Finally, the method of data analysis is not yet unified. Manuals or guide-books for this purpose are necessary for the mutual comparison of the data from the stations in different districts. (Kato, T.)

  10. Prevalence of diabetic retinopathy and its relationship with glomerular filtration rate and other risk factors in patients with type 2 diabetes mellitus in Spain. DM2 HOPE study.

    Science.gov (United States)

    López, Maribel; Cos, Francesc Xavier; Álvarez-Guisasola, Fernando; Fuster, Eva

    2017-09-01

    Diabetic retinopathy (DR) is the leading cause of blindness in working age population in developed countries. Albuminuria and estimated glomerular filtration rate (eGFR) have been considered biomarkers for DR. This study aimed to investigate the prevalence of DR and its relationship with eGFR and other risk factors in type 2 diabetic patients (T2DM) in Spain. A cross-sectional and descriptive study has been performed in 14,266 patients. Clinical records were reviewed. Demographic data, clinical diagnoses, clinical variables, and results from laboratory tests were recorded. Prevalence rates of DR were calculated. Logistic regression analysis was applied to assess predictors of the DR presence/absence. DR prevalence was 14.9%, being more prevalent in women (p = 0.0087) and in older patients (p < 0.0001). Duration of disease (OR = 5.3, IC95% = 3.8-7.4; p < 0.0001), eGFR < 60 ml/min/1.73 m 2 (OR = 2.0, IC95% 1.6-2.4; p < 0.0001), levels of HbA1c ≥ 7% (OR = 1.9, IC95% = 1.5-2.3; p < 0.0001) and high blood pressure (OR = 1.6, IC95% = 1.2-2.1; p = 0.0032) were associated with higher risk of DR. DR was also more frequent in patients taking insulin (32,6% vs. 10,2%; p < 0.0001). Around one in seven patients with T2DM has DR after nine years since diagnosis. Time since diagnosis, insulin therapy, cardiovascular profile, and renal dysfunction are associated with DR in patients with T2DM in Spain.

  11. Routine reporting of estimated glomerular filtration rate (eGFR) in African laboratories and the need for its increased utilisation in clinical practice.

    Science.gov (United States)

    Adebisi, Simeon A

    2013-03-01

    Chronic Kidney Disease (CKD) is defined as the presence of markers of kidney damage or of estimated glomerular filtration rate (eGFR)clinical practice. Current guidelines advocate the use of prediction equations, such as the Cockcroft-Gault (CG) formula and the Modification of Diet in Renal Disease (MDRD) study-derived equations. Laboratories in African should commence routine reporting of eGFR for a number of reasons; 1. The sensitivity of serum creatinine (Scr) in identifying CKD is low.2. In Nigeria, a representative country; screening for Chronic Kidney Disease (CKD) is hardly considered in the routine practice of the primary and secondary care medical officers.3 Studies have shown that routine reporting of eGFR improved the documentation and identification of CKD by almost 50%.4 There is the possibility of reversing CKD if picked earlier.5. The high cost of treating CKD patients in advanced stages and the low per capital income status of the populace in Sub-Saharan Africa.6. Poor health infrastructure to manage advanced CKD patients in the continent.7. Several studies, now show lack of awareness of CKD among non-nephrologists that is related, at least in part, to difficulty in interpreting serum creatinine concentrations (the reciprocal, non-linear relationship between GFR and serum creatinine).8 Mathematical estimates of GFR [ as in eGFR] that incorporate creatinine concentration, as well as factors affecting creatinine production rates, such as size, gender, age and ethnic background, are more sensitive to changes in renal function than serum creatinine value alone.9 Recent guidelines define "action plans" for CKD according to the GFR, including referral to nephrologists at GFRs<30 mL.min(-1).(1.73 m2).

  12. Importance of glomerular filtration rate change as surrogate endpoint for the future incidence of end-stage renal disease in general Japanese population: community-based cohort study.

    Science.gov (United States)

    Kanda, Eiichiro; Usui, Tomoko; Kashihara, Naoki; Iseki, Chiho; Iseki, Kunitoshi; Nangaku, Masaomi

    2018-04-01

    Because of the necessity for extended period and large costs until the event occurs, surrogate endpoints are indispensable for implementation of clinical studies to improve chronic kidney disease (CKD) patients' prognosis. Subjects with serum creatinine level for a baseline period over 1-3 years were enrolled (n = 69,238) in this community-based prospective cohort study in Okinawa, Japan, and followed up for 15 years. The endpoint was end-stage renal disease (ESRD). The percent of estimated glomerular filtration rate (%eGFR) change was calculated on the basis of the baseline period. Subjects had a mean ± SD age, 55.59 ± 14.69 years; eGFR, 80.15 ± 21.15 ml/min/1.73 m 2 . Among the subjects recruited, 15.81% had a low eGFR (<60 ml/min/1.73 m 2 ) and 36.1/100,000 person years developed ESRD. Cox proportional hazards models adjusted for baseline characteristics showed that the risk of ESRD tended to be high with high rates of decrease in %eGFR changes over 2 or 3 years in the high- and low-eGFR groups. The specificities and positive predictive values for ESRD based on a cutoff value of %eGFR change of less than -30% over 2 or 3 years were high in the high- and low-eGFR groups. %eGFR change tends to be associated with the risk of ESRD. %eGFR change of less than -30% over 2 or 3 years can be a candidate surrogate endpoint for ESRD in the general Japanese population.

  13. Increased circulating endothelial apoptotic microparticle to endothelial progenitor cell ratio is associated with subsequent decline in glomerular filtration rate in hypertensive patients.

    Directory of Open Access Journals (Sweden)

    Chien-Yi Hsu

    Full Text Available BACKGROUND: Recent research indicates hypertensive patients with microalbuminuria have decreased endothelial progenitor cells (EPCs and increased levels of endothelial apoptotic microparticles (EMP. However, whether these changes are related to a subsequent decline in glomerular filtration rate (GFR remains unclear. METHODS AND RESULTS: We enrolled totally 100 hypertensive out-patients with eGFR ≥ 30 mL/min/1.73 m(2. The mean annual rate of GFR decline (△GFR/y was -1.49 ± 3.26 mL/min/1.73 m(2 per year during the follow-up period (34 ± 6 months. Flow cytometry was used to assess circulating EPC (CD34(+/KDR(+ and EMP levels (CD31(+/annexin V(+ in peripheral blood. The △GFR/y was correlated with the EMP to EPC ratio (r= -0.465, p<0.001, microalbuminuria (r= -0.329, p=0.001, and the Framingham risk score (r= -0.245, p=0.013. When we divided the patients into 4 groups according to the EMP to EPC ratio, there was an association between the EMP to EPC ratio and the ΔGFR/y (mean ΔGFR/y: 0.08 ± 3.04 vs. -0.50 ± 2.84 vs. -1.25 ± 2.49 vs. -4.42 ± 2.82, p<0.001. Multivariate analysis indicated that increased EMP to EPC ratio is an independent predictor of ΔeGFR/y. CONCLUSIONS: An increased circulating EMP to EPC ratio is associated with subsequent decline in GFR in hypertensive patients, which suggests endothelial damage with reduced vascular repair capacity may contribute to further deterioration of renal function in patients with hypertension.

  14. Heartbeat Rate Measurement from Facial Video

    DEFF Research Database (Denmark)

    Haque, Mohammad Ahsanul; Irani, Ramin; Nasrollahi, Kamal

    2016-01-01

    Heartbeat Rate (HR) reveals a person’s health condition. This paper presents an effective system for measuring HR from facial videos acquired in a more realistic environment than the testing environment of current systems. The proposed method utilizes a facial feature point tracking method...... by combining a ‘Good feature to track’ and a ‘Supervised descent method’ in order to overcome the limitations of currently available facial video based HR measuring systems. Such limitations include, e.g., unrealistic restriction of the subject’s movement and artificial lighting during data capture. A face...

  15. Hot filtration 2

    International Nuclear Information System (INIS)

    Jimenez Rebagliati, Raul; Liberman, S.J.

    1982-01-01

    The magnetic filtration technique allows the removal of suspended magnetic species from a fluid at high flow rate and temperature. It is specially advantageous for water purification in systems such as thermonuclear and thermoelectric plants in which corrosion products must be removed from the heat transport and cooling circuits. Using diluted aqueous suspensions of magnetite, the behaviour of a ball matrix filter was studied as a function of flow rate, temperature and concentration of particles. The retention efficiency shows an exponential decay with fluid's velocity and viscosity in agreement with theory. Within the range of concentration considered, there is no change in the retention with concentration. Design parameters for filters according to plant's needs are obtained from the results of this study. (Author) [es

  16. Cross-flow filtration and axial filtration

    International Nuclear Information System (INIS)

    Kraus, K.A.

    1974-01-01

    Two relatively novel alternative solid-liquid-separation techniques of filtration are discussed. In cross-flow filtration, the feed is pumped past the filtering surface. While in axial filtration the filter, mounted on a rotor, is moved with respect to the feed. While large-scale application of the axial filter is still in doubt, it permits with little expenditure of time and money, duplication of many hydrodynamic aspects of cross-flow filtration for fine-particle handling problems. The technique has been applied to municipal wastes, low-level radioactive waste treatment plant, lead removal from industrial wastes, removal of pulp-mill contaminants, textile-mill wastes, and pretreatment of saline waters by lime-soda process in preparation for hyperfiltration. Economics and energy requirements are also discussed

  17. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  18. Magnetic-seeding filtration

    Energy Technology Data Exchange (ETDEWEB)

    DePaoli, D.W.; Tsouris, C. [Oak Ridge National Lab., TN (United States); Yiacoumi, Sotira

    1997-10-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process.

  19. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    DePaoli, D.W.; Tsouris, C.; Yiacoumi, Sotira.

    1997-01-01

    Magnetic-seeding filtration is a technology under development for the enhanced removal of magnetic and non-magnetic particulates from liquids. This process involves the addition of a small amount of magnetic seed particles (such as naturally occurring iron oxide) to a waste suspension, followed by treatment with a magnetic filter. Non-magnetic and weakly magnetic particles are made to undergo nonhomogeneous flocculation with the seed particles, forming flocs of high magnetic susceptibility that are readily removed by a conventional high-gradient magnetic filter. This technology is applicable to a wide range of liquid wastes, including groundwater, process waters, and tank supernatants. Magnetic-seeding filtration may be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes. Waste stream characteristics for which the technology may be applicable include (1) particle sizes ranging from relatively coarse (several microns) to colloidal particles, (2) high or low radiation levels, (3) broad-ranging flow rates, (4) low to moderate solids concentration, (5) cases requiring high decontamination factors, and (6) aqueous or non-aqueous liquids. At this point, the technology is at the bench-scale stage of development; laboratory studies and fundamental modeling are currently being employed to determine the capabilities of the process

  20. Filtration and retention capacities of filter aids

    International Nuclear Information System (INIS)

    Mellah, A.; Boualia, A.

    1992-01-01

    The present work involves the filtration of impure uranyl nitrate solutions by different filter aids such as kieselguhr, celite and bleaching clay. The retention of substances contained in uranyl nitrate solution was determined using the three filter aids. A study of the effects of granulometry and filter earths treatment (thermal and chemical) on the filtration rate was performed

  1. Retrospective study of renal distribution volume with DTPA-{sup 99m}Tc: performance of single plasma method for glomerular filtration rate estimation; Etude retrospective du volume de distribution du traceur renal DTPA-{sup 99m}Tc: performance d`une methode a un prelevement sanguin pour l`estimation du debit de filtration glomerulaire

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P. [Centre Hospitalier Regional Augustin-Morvan, 29 - Brest (France)

    1997-08-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours) three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m{sup 2}). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m{sup 2} (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V)). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR{sub 234} = f (V{sub 4h}) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen`s equation. (authors). 17 refs.

  2. Reduced estimated glomerular filtration rate (eGFR 73 m2 ) at first transurethral resection of bladder tumour is a significant predictor of subsequent recurrence and progression.

    Science.gov (United States)

    Blute, Michael L; Kucherov, Victor; Rushmer, Timothy J; Damodaran, Shivashankar; Shi, Fangfang; Abel, E Jason; Jarrard, David F; Richards, Kyle A; Messing, Edward M; Downs, Tracy M

    2017-09-01

    To evaluate if moderate chronic kidney disease [CKD; estimated glomerular filtration rate (eGFR) 73 m 2 ] is associated with high rates of non-muscle-invasive bladder cancer (NMIBC) recurrence or progression. A multi-institutional database identified patients with serum creatinine values prior to first transurethral resection of bladder tumour (TURBT). The CKD-epidemiology collaboration formula calculated patient eGFR. Cox proportional hazards models evaluated associations with recurrence-free (RFS) and progression-free survival (PFS). In all, 727 patients were identified with a median (interquartile range [IQR]) patient age of 69.8 (60.1-77.6) years. Data for eGFR were available for 632 patients. During a median (IQR) follow-up of 3.7 (1.5-6.5) years, 400 (55%) patients had recurrence and 145 (19.9%) patients had progression of tumour stage or grade. Moderate or severe CKD was identified in 183 patients according to eGFR. Multivariable analysis identified an eGFR of 73 m 2 (hazard ratio [HR] 1.5, 95% confidence interval [CI]: 1.2-1.9; P = 0.002) as a predictor of tumour recurrence. The 5-year RFS rate was 46% for patients with an eGFR of ≥60 mL/min/1.73 m 2 and 27% for patients with an eGFR of 73 m 2 (P 73 m 2 (HR 3.7, 95% CI: 1.75-7.94; P = 0.001) was associated with progression to muscle-invasive disease. The 5-year PFS rate was 83% for patients with an eGFR of ≥60 mL/min/1.73 m 2 and 71% for patients with an eGFR of 73 m 2 (P = 0.01). Moderate CKD at first TURBT is associated with reduced RFS and PFS. Patients with reduced renal function should be considered for increased surveillance. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  3. Correlation between glomerular filtration rate with gamma camera and estimated serum creatinine clearance from Cockcroft and Gault's formula

    International Nuclear Information System (INIS)

    Bhushan, Shivanand; Kumar, Rajesh

    2012-01-01

    The purpose of the present study is to find out the correlation between the glomerular filtration rate (GFR by Gates gamma camera method) and serum creatinine clearance (SCrCl by Cockcroft and Gault's method) within ± 3 weeks’ time difference. Study design retrospectively in 59 patients with serum creatinine value calculated for SCrCl with Cockcroft and Gault's formula as an index parameter for kidney function underwent the 99m-Technitium labeled Di-ethyl Triamine Penta Acetic Acid (99mTc-DTPA) renogram with ECIL planar gamma camera. All data of 59 patients has been divided into Group- I, II, and III based on the time difference of serum creatinine test from 99mTc-DTPA renal GFR tests performed on the same subjects. Serum Creatinine test was carried out within ± 3 days, between ± 4 days and ± 7 days, and between ± 8 days and ± 21 days from the DTPA GFR Test performed in the Group-I, II, and III respectively. Correlation coefficient of Group-I (n = 15) patients showed 0.8198 and P value < 0.001 for GFR and S. Creatinine within ± 3 days. Group-II (n = 17) and Group-III (n = 27) patients having correlation coefficient 0.6194 and 0.589 and P value <0.01 respectively, within ± 21 days. The two methods gave almost identical estimate of GFR even at 3 weeks interval. Study concludes that SCrCl using Cockcroft and Gault's formula could serve as an instant, easy, and reliable method for assessing kidney function. SCrCl with Cockcroft and Gault's formula is more useful for rapid estimation of global GFR for those patients who are not accessible to DTPA renogram with gamma camera. Correlation can be established further with the prospective study in various renal pathophysiological conditions

  4. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.

    Science.gov (United States)

    Matsuda, Yuri; Kishimoto, Miori; Kushida, Kazuya; Yamada, Kazutaka; Shimizu, Miki; Itoh, Hiroshi

    2017-09-01

    OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.

  5. Estimated glomerular filtration rate is a poor predictor of the concentration of middle molecular weight uremic solutes in chronic kidney disease.

    Directory of Open Access Journals (Sweden)

    Nathalie Neirynck

    Full Text Available BACKGROUND: Uremic solute concentration increases as Glomerular Filtration Rate (GFR declines. Weak associations were demonstrated between estimated GFR (eGFR and the concentrations of several small water-soluble and protein-bound uremic solutes (MW500 Da. MATERIALS AND METHODS: In 95 CKD-patients (CKD-stage 2-5 not on dialysis, associations between different eGFR-formulae (creatinine, Cystatin C-based or both and the natural logarithm of the concentration of several LMWP's were analyzed: i.e. parathyroid hormone (PTH, Cystatin C (CystC, interleukin-6 (IL-6, tumor necrosis factor-alpha (TNF-α, leptin, retinol binding protein (RbP, immunoglobin light chains kappa and lambda (Ig-κ and Ig-λ, beta-2-microglobulin (β(2M, myoglobin and fibroblast growth factor-23 (FGF-23. RESULTS: The regression coefficients (R(2 between eGFR, based on the CKD-EPI-Crea-CystC-formula as reference, and the examined LMWP's could be divided into three groups. Most of the LMWP's associated weakly (R(2 0.7. Almost identical R(2-values were found per LMWP for all eGFR-formulae, with exception of CystC and β(2M which showed weaker associations with creatinine-based than with CystC-based eGFR. CONCLUSION: The association between eGFR and the concentration of several LMWP's is inconsistent, with in general low R(2-values. Thus, the use of eGFR to evaluate kidney function does not reflect the concentration of several LMWP's with proven toxic impact in CKD.

  6. Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

    International Nuclear Information System (INIS)

    Frennby, B.; Almen, T.

    2001-01-01

    The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r=0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol). (orig.)

  7. Associations of Perfluoroalkyl Substances (PFAS) with Lower Birth Weight: An Evaluation of Potential Confounding by Glomerular Filtration Rate Using a Physiologically Based Pharmacokinetic Model (PBPK).

    Science.gov (United States)

    Verner, Marc-André; Loccisano, Anne E; Morken, Nils-Halvdan; Yoon, Miyoung; Wu, Huali; McDougall, Robin; Maisonet, Mildred; Marcus, Michele; Kishi, Reiko; Miyashita, Chihiro; Chen, Mei-Huei; Hsieh, Wu-Shiun; Andersen, Melvin E; Clewell, Harvey J; Longnecker, Matthew P

    2015-12-01

    Prenatal exposure to perfluoroalkyl substances (PFAS) has been associated with lower birth weight in epidemiologic studies. This association could be attributable to glomerular filtration rate (GFR), which is related to PFAS concentration and birth weight. We used a physiologically based pharmacokinetic (PBPK) model of pregnancy to assess how much of the PFAS-birth weight association observed in epidemiologic studies might be attributable to GFR. We modified a PBPK model to reflect the association of GFR with birth weight (estimated from three studies of GFR and birth weight) and used it to simulate PFAS concentrations in maternal and cord plasma. The model was run 250,000 times, with variation in parameters, to simulate a population. Simulated data were analyzed to evaluate the association between PFAS levels and birth weight due to GFR. We compared simulated estimates with those from a meta-analysis of epidemiologic data. The reduction in birth weight for each 1-ng/mL increase in simulated cord plasma for perfluorooctane sulfonate (PFOS) was 2.72 g (95% CI: -3.40, -2.04), and for perfluorooctanoic acid (PFOA) was 7.13 g (95% CI: -8.46, -5.80); results based on maternal plasma at term were similar. Results were sensitive to variations in PFAS level distributions and the strength of the GFR-birth weight association. In comparison, our meta-analysis of epidemiologic studies suggested that each 1-ng/mL increase in prenatal PFOS and PFOA levels was associated with 5.00 g (95% CI: -21.66, -7.78) and 14.72 g (95% CI: -8.92, -1.09) reductions in birth weight, respectively. Results of our simulations suggest that a substantial proportion of the association between prenatal PFAS and birth weight may be attributable to confounding by GFR and that confounding by GFR may be more important in studies with sample collection later in pregnancy.

  8. Inflammation and renal function after a four-year follow-up in subjects with unimpaired glomerular filtration rate: results from the observational, population-based CARLA cohort.

    Directory of Open Access Journals (Sweden)

    Daniel Medenwald

    Full Text Available There is evidence that chronic inflammation is associated with the progression/development of chronic renal failure; however, relations in subjects with preserved renal function remain insufficiently understood.To examine the association of inflammation with the development of renal failure in a cohort of the elderly general population.After excluding subjects with reduced estimated glomerular filtration rate (eGFR<60 mL/min/1.73 m2 and missing data, the cohort incorporated 785 men and 659 women (aged 45-83 years. Follow-up was performed four years after baseline. Covariate adjusted linear and logistic regression models were used to assess the association of plasma/serum concentrations of soluble tumour necrosis factor receptor 1 (sTNF-R1, C-reactive protein (CRP, and interleukin 6 (IL-6 with change in eGFR/creatinine. The areas under the curve (AUCs from receiver operating characteristics (ROCs were estimated.In adjusted models sTNF-R1 was distinctively associated with a decline in eGFR in men (0.6 mL/min/1.73 m2 per 100 pg/mL sTNF-R1; 95% CI: 0.4-0.8, but not in women. A similar association could not be found for CRP or IL-6. Estimates of sTNF-R1 in the cross-sectional analyses were similar between sexes, while CRP and IL-6 were not relevantly associated with eGFR/creatinine.In the elderly male general population with preserved renal function sTNF-R1 predicts the development of renal failure.

  9. Prevalence of Reduced Kidney Function by Estimated Glomerular Filtration Rate Using an Equation Based on Creatinine and Cystatin C in Metabolic Syndrome and Its Components in Korean Adults

    Directory of Open Access Journals (Sweden)

    Yang Ho Kang

    2016-09-01

    Full Text Available BackgroundIt is known that metabolic syndrome (MetS is associated with chronic kidney disease. We evaluated and compared the prevalence of reduced kidney function in MetS and its components by estimated glomerular filtration rate (eGFR using an equation based on creatinine (eGFRcr, cystatin C (eGFRcys, and combined creatinine-cystatin C (eGFRcr-cys in Korean adults.MethodsWe analyzed data from 3,649 adults who participated in a comprehensive health examination.ResultsMean values of eGFRcys were higher compared with mean values of eGFRcr (96.1±18.2 mL/min/1.73 m2 vs. 91.2±13.6 mL/min/1.73 m2 in total subjects. The prevalence of reduced kidney function increased with age (9.6% for eGFRcys vs. 5.8% for eGFRcr-cys vs. 4.9% for eGFRcr, in subjects aged ≥60 years, and significantly increased with MetS, abdominal obesity, hypertension, high triglyceride, low high density lipoprotein (HDL, and high insulin resistance. The prevalence of MetS, abdominal obesity, hypertension, high insulin resistance, low HDL, and hepatic steatosis was significantly increased in subjects with reduced kidney function. This increased prevalence and the odds ratio of reduced kidney function for prevalence of MetS was highest for eGFRcys, followed by those of eGFRcr-cys, and eGFRcr.ConclusionThe prevalence of reduced kidney function by eGFR was significantly increased in subjects with MetS and its related components. eGFRcys and eGFRcr-cys were superior to eGFRcr in detecting reduced kidney function.

  10. Polymorphisms in the non-muscle myosin heavy chain gene (MYH9 are associated with lower glomerular filtration rate in mixed ancestry diabetic subjects from South Africa.

    Directory of Open Access Journals (Sweden)

    Tandi Edith Matsha

    Full Text Available OBJECTIVE: Though single nucleotide polymorphisms (SNPs in the non-muscle myosin gene (MYH9 have been reported to explain most of the excess risk of nondiabetic chronic kidney disease (CKD, in African-Americans, some studies have also shown associations with diabetic end-stage renal disease. We investigated the association of MYH9 SNPs with renal traits in a mixed-ancestry South African population prone to diabetes. RESEARCH DESIGN AND METHODS: Three SNPs known to be associated with CKD (rs4821480, rs5756152 and rs12107 were genotyped using Taqman assay in 716 adults (198 with diabetes from the Bellville-South community, Cape Town. Glomerular filtration rate was estimated (eGFR and urinary albumin/creatinine ratio (ACR assessed. Multivariable regressions were used to relate the SNPs with renal traits. RESULTS: Mean age was 53.6 years, with the expected differences observed in characteristics by diabetic status. Significant associations were found between rs575152 and serum creatinine, and eGFR in the total population, and in diabetic participants (all p≤0.003, but not in non-diabetics (all p≥0.16, with significant interactions by diabetes status (interaction-p≤0.009. The association with ACR was borderline in diabetic participants (p = 0.05 and non-significant in non-diabetics (p = 0.85, with significant interaction (interaction p = 0.02. rs12107 was associated with fasting-, 2-hour glucose and HbA1c in diabetic participants only (interaction-p≤0.003, but not with renal traits. CONCLUSION: MYH9 SNPs were associated with renal traits only in diabetic participants in this population. Our findings and other studies suggest that MYH9 may have a broader genetic risk effect on kidney diseases.

  11. Prevalence and determinants of differences in cystatin C and creatinine-based estimated glomerular filtration rate in community-dwelling older adults: a cross-sectional study.

    Science.gov (United States)

    Legrand, Helen; Werner, Karin; Christensson, Anders; Pihlsgård, Mats; Elmståhl, Sölve

    2017-12-04

    Differences in cystatin C and creatinine-based estimated glomerular filtration rate (eGFR) can lead to clinical uncertainty. Existing eGFR equations perform poorly in a subset of individuals. This study aims to describe the prevalence of differences between cystatin C-based (eGFR cys ) and creatinine-based (eGFR creat ) eGFR in older adults and to explore which subsets of individuals may be most affected by differing estimations. In this cross-sectional study, participants from a cohort of community-dwelling older adults were examined at a baseline visit in 2001-2004 as part of the larger "Good Aging in Skåne" study. Exposure variables were obtained from questionnaires, interviews, examinations, and medical records. Blood samples were taken during the baseline visit, cryopreserved, and analyzed at a later time for biomarkers. The CKD-EPI equations were used to estimate GFR. Initial descriptive analyses were performed on 2931 individuals. A total of 2532 participants were included in the final multiple linear regression. Nearly two-thirds of participants had eGFR differences exceeding 10%, with nearly 20 % of participants having eGFR differences exceeding 30%. Smoking, age, body mass index (BMI), C-reactive protein (CRP), glucocorticoid use, and mean eGFR were correlated with differences between eGFR creat and eGFR cys . Differences between eGFR creat and eGFR cys are common and often of large magnitude in this community-dwelling population of older adults. The finding of multiple non-GFR determinants correlated to differences in GFR estimations can help direct future research to improve eGFR equations for subgroups prone to conflicting GFR estimations or to guide choice of biomarker for GFR estimation in these subgroups.

  12. In situ method for measurements of community clearance rate on shallow water bivalve populations

    DEFF Research Database (Denmark)

    Hansen, Benni W.; Dolmer, Per; Vismann, Bent

    2011-01-01

    An open-top chamber was designed for measuring ambient community clearance rate on undisturbed bivalve populations in the field. The chamber was pressed 5-10 cm down in the sediment on the mussel bed. It holds approximately 30-40 cm water column equal to a volume of 43-77 L. It was provided...... with an air lift connected to a SCUBA diver pressure tank generating a continuous and gentle water circulation. This ensures a complete mixture of suspended particles, and thereby, a maximum filtration by the bivalves. An in situ fluorometer was mounted to record plant pigment reduction due to mussel...

  13. Measurement of leach rates: a review

    International Nuclear Information System (INIS)

    Mendel, J.E.

    1982-01-01

    A historical perspective of the techniques that can be used to measure the leach rate of radioactive waste forms is presented. The achievement of leach rates that are as low as possible has been an important goal ever since the development of solidification processes for liquid radioactive wastes began in the 1950's. Leach tests can be divided into two major categories, dynamic and static, based on whether or not the leachant in contact with the test specimen is changed during the course of the test. Both types of tests have been used extensively. The results of leach tests can be used to compare waste forms, and that has been a major purpose of leach data heretofore; increasingly, however, the data now are needed for predicting long-term leaching behavior during geologic disposal. This requirement is introducing new complexities into leach testing methodology. 3 figures, 2 tables

  14. Flow rate measurement in a volume

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, Cristhian

    2018-04-17

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

  15. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki (Dept. of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)), email: utsunomi@kumamoto-u.ac.jp; Awai, Kazuo (Dept. of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima Univ., Hiroshima (Japan)); Funama, Yoshinori (Dept. of Medical Physics, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan))

    2011-06-15

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 +- 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m2) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 < =eGFR < 90, 45 < =eGFR < 60, 30 < =eGFR < 45 and eGFR < 30, respectively. Results Of the 6586 patients, 1.6%, 3.7%, 13.7%, and 54.2% were judged to present with severe, moderate-b, moderate-a, and mild RI, respectively. While moderate-b-to-severe RI was recorded in 133 (3.2%) of 4161 patients aged 70 years or less, it was observed in 218 (9.0%) of the 2425 patients who were 71 years or older. Among the 829 CVD patients, 9.9% manifested moderate-b-to-severe- and 73.0% mild-to-moderate-a RI. The corresponding rates were 4.4% and 68.9% for oncologic disease, 16.9% and 61.2% for DM, and 4.8% and 71.5% for CLD patients. By univariate analysis, there was a significant association between moderate-b-to-severe RI and the advanced age, CVD, DM, and non-oncologic disease. Multivariate analysis showed that the advanced age, DM, and non-oncologic disease were statistically associated with moderate-b-to-severe RI. Conclusion The incidence of RI of eGFR < 45mL/min/1.73 m2 at baseline was high in patients with advanced age, CVD and DM and

  16. Filtration approach to mitigate indoor Thoron progeny concentration

    International Nuclear Information System (INIS)

    Wang, J.; Meisenberg, O.; Karg, E.; Tschiersch, J.; Chen, Y.

    2010-01-01

    This study investigates filtration of air as potential mitigation method of thoron progeny exposure. The experiments were conducted in a model room (volume 7.1 m 3 ) which was equipped with a pump and an HEPA (high efficiency particulate air) filter. Filtration at a rate of 0.2, 0.4, 0.5 and 0.8 h -1 during 88 h proved an effective practice in reducing the total indoor thoron decay product concentration. The results indicate that 0.4-0.8 h -1 filtration rate had almost the same filtration efficiency in decreasing the total thoron EEC (equilibrium equivalent concentration) by 97% while 80% of total thoron EEC were reduced by 0.2 h -1 filtration rate; meanwhile, the unattached thoron EEC rose significantly by 190, 270, 290%, respectively under 0.4-0.8 h -1 filtration rate, whereas 0.2 h -1 filtration rate increased unattached thoron EEC by 40%. The aerosol number size distribution variation reveals that filtration operation removes smaller particles faster or earlier than the larger ones. The annual effective dose calculated was reduced by 91-92% at a filtration rate of 0.4-0.8 h -1 while 75% reduced at 0.2 h -1 filtration rate after 88 h filtration process. (authors)

  17. Applicability of the Schwartz Equation and the Chronic Kidney Disease in Children Bedside Equation for Estimating Glomerular Filtration Rate in Overweight Children.

    Science.gov (United States)

    Lewis, Teresa V; Harrison, Donald L; Gildon, Brooke L; Carter, Sandra M; Turman, Martin A

    2016-06-01

    To determine if significant correlations exist between glomerular filtration rate (GFR) prediction equation values, derived by using the original Schwartz equation and the Chronic Kidney Disease in Children (CKiD) bedside equation with a 24-hour urine creatinine clearance (Clcr ) value normalized to a body surface area of 1.73 m(2) in overweight and obese children. Prospective analysis (20 patients) and retrospective analysis (43 patients). Pediatric inpatient ward and pediatric nephrology clinic at a comprehensive academic medical center. Sixty-three pediatric patients (aged 5-17 years), of whom 27 were overweight (body mass index [BMI] at the 85th percentile or higher) and 36 were not overweight (BMI lower than the 85th percentile [controls]) between 2007 and 2012. Data from the overweight patients were compared with nonoverweight controls. GFR values were calculated by using the original Schwartz equation and the CKiD bedside equation. Each patient's 24-hour urine Clcr value normalized to a body surface area of 1.73 m(2) served as the index value. A Pearson correlation coefficient model was used to determine association between the 24-hour urine Clcr value (index value) with the Schwartz and CKiD GFR estimations. Significant correlation was found to exist between the Schwartz and CKiD bedside GFR estimations relative to the 24-hour urine Clcr in the control subjects (r = 0.85, poverweight subjects (r = 0.86, poverweight children with a kidney disorder. The CKiD bedside GFR estimations were not significantly different compared with 24-hour urine Clcr values for the overweight group with kidney disorder (p=0.85). The Schwartz and CKiD bedside estimations of GFR correlated with 24-hour urine Clcr values in both overweight and nonoverweight children. Compared with the Schwartz equation, which tended to overestimate renal function, the CKiD bedside equation appeared to approximate 24-hour urine Clcr more closely in overweight children with kidney disorder. © 2016

  18. Multicenter study of creatinine- and/or cystatin C-based equations for estimation of glomerular filtration rates in Chinese patients with chronic kidney disease.

    Directory of Open Access Journals (Sweden)

    Jia-fu Feng

    Full Text Available OBJECTIVE: To establish equations for the estimation of glomerular filtration rates (eGFRs based on serum creatinine (SCr and/or serum cystatin C (SCysC in Chinese patients with chronic kidney disease (CKD, and to compare the new equations with both the reference GFR (rGFR and the literature equations to evaluate their applicability. METHODS: The 788 Chinese CKD patients were randomly divided into two groups, the training group and the testing group, to establish new eGFR-formulas based on serum CysC and to validate the established formulas, respectively. (99mTc-DTPA clearance (as the rGFR, serum Cr, and serum CysC were determined for all patients, and GFR was calculated using the Cockcroft-Gault equation (eGFR1, the MDRD formula (eGFR2, the CKD-EPI formulas (eGFR3, eGFR4, and the Chinese eGFR Investigation Collaboration formulas (eGFR5, eGFR6. The accuracy of each eGFR was compared with the rGFR. RESULTS: The training and testing groups' mean GFRs were 50.84±31.36 mL/min/1.73 m(2 and 54.16±29.45 mL/min/1.73 m(2, respectively. The two newly developed eGFR formulas were fitted using iterative computation: [Formula: see text] and [Formula: see text]. Significant correlation was observed between each eGFR and the rGFR. However, proportional errors and constant errors were observed between rGFR and eGFR1, eGFR2, eGFR4, eGFR5 or eGFR6, and constant errors were observed between eGFR3 and rGFR, as revealed by the Passing & Bablok plot analysis. The Bland-Altman analysis illustrated that the 95% limits of agreement of all equations exceeded the previously accepted limits of <60 mL/min •1.73 m(2, except the equations of eGFR7 and eGFR8. CONCLUSION: The newly developed formulas, eGFR7 and eGFR8, provide precise and accurate GFR estimation using serum CysC detection alone or in combination with serum Cr detection. Differences in detection methods should be carefully considered when choosing literature eGFR equations to avoid misdiagnosis and

  19. Comparison of equations for estimating glomerular filtration rate in screening for chronic kidney disease in asymptomatic black Africans: a cross sectional study.

    Science.gov (United States)

    Omuse, Geoffrey; Maina, Daniel; Mwangi, Jane; Wambua, Caroline; Kanyua, Alice; Kagotho, Elizabeth; Amayo, Angela; Ojwang, Peter; Erasmus, Rajiv

    2017-12-20

    Several equations have been developed to estimate glomerular filtration rate (eGFR). The common equations used were derived from populations predominantly comprised of Caucasians with chronic kidney disease (CKD). Some of the equations provide a correction factor for African-Americans due to their relatively increased muscle mass and this has been extrapolated to black Africans. Studies carried out in Africa in patients with CKD suggest that using this correction factor for the black African race may not be appropriate. However, these studies were not carried out in healthy individuals and as such the extrapolation of the findings to an asymptomatic black African population is questionable. We sought to compare the proportion of asymptomatic black Africans reported as having reduced eGFR using various eGFR equations. We further compared the association between known risk factors for CKD with eGFR determined using the different equations. We used participant and laboratory data collected as part of a global reference interval study conducted by the Committee of Reference Intervals and Decision Limits (C-RIDL) under the International Federation of Clinical Chemistry (IFCC). Serum creatinine values were used to calculate eGFR using the Cockcroft-Gault (CG), re-expressed 4 variable modified diet in renal disease (4v-MDRD), full age spectrum (FAS) and chronic kidney disease epidemiology collaboration equations (CKD-EPI). CKD classification based on eGFR was determined for every participant. A total of 533 participants were included comprising 273 (51.2%) females. The 4v-MDRD equation without correction for race classified the least number of participants (61.7%) as having an eGFR equivalent to CKD stage G1 compared to 93.6% for CKD-EPI with correction for race. Only age had a statistically significant linear association with eGFR across all equations after performing multiple regression analysis. The multiple correlation coefficients for CKD risk factors were higher for

  20. Interfering RNA against PKC-α Inhibits TNF-α-induced IP3R1 Expression and Improves Glomerular Filtration Rate in Rats with Fulminant Hepatic Failure.

    Science.gov (United States)

    Wang, Dong-Lei; Dai, Wen-Ying; Wang, Wen; Wen, Ying; Zhou, Ying; Zhao, Yi-Tong; Wu, Jian; Liu, Pei

    2018-01-10

    We have reported that tumor necrosis factor- (TNF-α) is critical for reduction of glomerular filtration rate (GFR) in rats with fulminant hepatic failure (FHF). The present study aims to evaluate the underlying mechanisms of decreased GFR during acute hepatic failure. Rats with FHF induced by D-galactosamine plus lipopolysaccharide (GalN/LPS) were injected intravenously with recombinant lentivirus harboring shRNA against the protein kinase C-α (PKC-α) gene (Lenti-shRNA-PKC-α). GFR, serum levels of aminotransferases, creatinine, urea nitrogen, potassium, sodium, chloride, TNF-α and endothelin-1 (ET-1), as well as type 1 inositol 1,4,5-trisphosphate receptor (IP3R1) expression in renal tissue were assessed. The effects of PKC-α silencing on TNF-α-induced IP3R1, specificity protein 1 (SP-1) and c-Jun N-terminal kinase (JNK) expression, as well as cytosolic calcium content were determined in glomerular mesangial cell (GMCs) with RNAi against PKC-α. Renal IP3R1 overexpression was abrogated by pre-treatment with Lenti-shRNA-PKC-α. The PKC- silence significantly improved the compromised GFR, reduced Cr levels, and reversed the decrease in glomerular inulin space and the increase in glomerular calcium content in GalN/LPS-exposed rats. TNF-α treatment increased expression of PKC-α, IP3R1, specificity protein 1 (SP-1), JNK and p-JNK in GMCs, and increased Ca2+ release and binding activity of SP-1 to the IP3R1 promoter. These effects were blocked by transfection of siRNA against the PKC-α gene, and the PKC-α gene silence also restored cytosolic [Ca2+]i. RNAi targeting PKC-α inhibited TNF-α-induced IP3R1 overexpression, and in turn improved compromised GFR in the development of acute kidney injury during FHF in rats.

  1. Particle filtration in consolidated granular systems

    International Nuclear Information System (INIS)

    Schwartz, L.M.; Wilkinson, D.J.; Bolsterli, M.; Hammond, P.

    1993-01-01

    Grain-packing algorithms are used to model the mechanical trapping of dilute suspensions of particles by consolidated granular media. We study the distribution of filtrate particles, the formation of a damage zone (internal filter cake), and the transport properties of the host--filter-cake composite. At the early stages of filtration, our simulations suggest simple relationships between the structure of the internal filter cake and the characteristics of the underlying host matrix. These relationships are then used to describe the dynamics of the filtration process. Depending on the grain size and porosity of the host matrix, calculated filtration rates may either be greater than (spurt loss) or less than (due to internal clogging) those predicted by standard surface-filtration models

  2. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  3. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  4. An epidemiologic model to project the impact of changes in glomerular filtration rate on quality of life and survival among persons with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Levy AR

    2014-07-01

    Full Text Available Adrian R Levy,1,2 Robert M Perkins,3 Karissa M Johnston,2 Sean D Sullivan,4 Vipan C Sood,5 Wendy Agnese,5 Mark A Schnitzler61Department of Community Health and Epidemiology, Dalhousie University, Halifax, NS, Canada; 2Oxford Outcomes Ltd, Vancouver, BC, Canada; 3Center for Health Research and Division of Nephrology, Geisinger Health System, Danville, PA, USA; 4School of Pharmacy, University of Washington, Seattle, WA, USA; 5Mitsubishi Tanabe Pharma America, Jersey City, NJ, USA; 6Departments of Internal Medicine and Community Health, Saint Louis University, St Louis, MO, USAPurpose: Predicting the timing and number of end-stage renal disease (ESRD cases from a population of individuals with pre-ESRD chronic kidney disease (CKD has not previously been reported. The objective is to predict the timing and number of cases of ESRD occurring over the lifetime of a cohort of hypothetical CKD patients in the US based on a range of baseline estimated glomerular filtration rate (eGFR values and varying rates of eGFR decline.Methods: A three-state Markov model – functioning kidney, ESRD, and death – with an annual cycle length is used to project changes in baseline eGFR on long-term health outcomes in a hypothetical cohort of CKD patients. Using published eGFR-specific risk equations and adjusting for predictive characteristics, the probability of ESRD (eGFR <10, time to death, and incremental cost-effectiveness ratios for hypothetical treatments (costing US$10, $5, and $2/day, are projected over the cohort's lifetime under two scenarios: an acute drop in eGFR (mimicking acute kidney injury and a reduced hazard ratio for ESRD (mimicking an effective intervention.Results: Among CKD patients aged 50 years, an acute eGFR decrement from 45 mL/minute to 35 mL/minute yields decreases of 1.6 life-years, 1.5 quality-adjusted life-years (QALYs, 0.8 years until ESRD, and an increase of 183 per 1,000 progressing to ESRD. Among CKD patients aged 60 years, lowering

  5. Measuring the costs of exchange rate volatility

    OpenAIRE

    Paul R. Bergin

    2004-01-01

    Many countries go to great lengths to manage their exchange rates. Probably the most prominent recent example is the European Monetary Union, where all the members abandoned their national currencies and adopted the euro. A number of developing countries maintain other kinds of regimes of managed exchange rates, even though they face potent market pressures to let their exchange rates float. One of the main motives for these arrangements stems from the extreme volatility of exchange rates. Th...

  6. Measuring Implicit Rental Rates for Farm Capital

    OpenAIRE

    Hrubovcak, James

    1986-01-01

    Developing implicit rental rates for capital inputs is an Important step in understanding the Impact of tax law changes on agricultural investments This article develops a methodology for estimating implicit rental rates and presents annual estimates of rental rates for seven categories of farm equipment and structures from 1955 to 1979 This article also compares these rental rates With those estimated under a no-tax alternative The author developed a method for estimating marginal Federal In...

  7. Association of Estimated Glomerular Filtration Rate with Hemoglobin Level in Korean Adults: The 2010-2012 Korea National Health and Nutrition Examination Survey.

    Directory of Open Access Journals (Sweden)

    Sang Youb Han

    Full Text Available Little is known about anemia in patients with early renal dysfunction. We aimed to investigate the association of hemoglobin level and anemia prevalence with estimated glomerular filtration rate (eGFR decline using a nation-wide representative sample of the adult Korean population.In total, 17,373 participants (7,296 men; weighted n = 18,330,187; mean age, 44.2±0.3 years; 9,886 women, weighted n = 18,317,454; mean age, 46.9±0.3 years were included. eGFR was divided into 5 groups: Group 1, ≥105; Group 2, 90-104; 75-89; Group 4, 60-74; and Group 5, <60 mL/min/1.73m2.The weighted anemia prevalence rates were 2.6% in men and 12.8% in women. In men, the weighted hemoglobin level increased with a decrease in eGFR; this value peaked at an eGFR of 60-89 mL/min/1.73m2 and decreased thereafter at an eGFR of <60 mL/min/1.73m2 (15.19±0.03, 15.35±0.03, 15.53±0.03, 15.52±0.06, and 14.90±0.12 g/dL from Groups 1 to 5 after adjustment for age, college graduation, cancer history, current smoking, waist circumference, serum cholesterol level, serum triglyceride level, and diastolic blood pressure. In women, the weighted hemoglobin level increased with a decrease in eGFR; this value peaked with an eGFR of 75-89 mL/min/1.73m2 and decreased thereafter (12.90±0.03, 13.08±0.02, 13.20±0.04, 13.14±0.05, and 12.47±0.11 g/dL from Groups 1 to 5 after adjustment for menstruation, pregnancy, estrogen replacement, and the above-mentioned variables. In both sexes, the weighted prevalence of anemia with an eGFR of 60-104 mL/min/1.73m2 was significantly lower than that with an eGFR of ≥105 mL/min/1.73m2 (men, 3.2±0.4%, 1.9±0.3%, 1.8±0.3%, 2.0±0.9%, and 18.1±3.1%; women, 14.0±0.8%, 11.2±0.7%, 10.5±1.0%, 13.2±1.6%, and 32.3±3.2% from Groups 1 to 5.We noted a compensatory increase in the hemoglobin level with a minor decline in kidney function (in the range of eGFR ≥60 mL/min/1.73m2 prior to a marked decrease in hemoglobin level with severe renal

  8. Determination of chromate ion in drilling mud filtrates

    International Nuclear Information System (INIS)

    Whitfill, D.

    1980-01-01

    A method of determining the amount of chromate ion in an aqueous drilling mud filtrate containing organic color bodies such as lignosulfate wherein the method comprises: (A) treating the aqueous filtrate with an effective amount of hydrogen peroxide to destroy said color bodies, and (B) measuring the amount of chromate ion in the filtrate by means of a spectrophotometer

  9. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Ying, T.Y.; Chin, C.J.; Lu, S.C.; Yiacoumi, S.

    1997-10-01

    Magnetic-seeding filtration consists of two steps: heterogeneous particle flocculation of magnetic and nonmagnetic particles in a stirred tank and high-gradient magnetic filtration (HGMF). The effects of various parameters affecting magnetic-seeding filtration (HGMF). The effects of various parameters affecting magnetic seeding filtration are theoretically and experimentally investigated. A trajectory model that includes hydrodynamic resistance, van der Waals, and electrostatic forces is developed to calculate the flocculation frequency in a turbulent-shear regime. Fractal dimension is introduced to simulate the open structure of aggregates. A magnetic-filtration model that consists of trajectory analysis, a particle build-up model, a breakthrough model, and a bivariate population-balance model is developed to predict the breakthrough curve of magnetic-seeding filtration. A good agreement between modeling results and experimental data is obtained. The results show that the model developed in this study can be used to predict the performance of magnetic-seeding filtration without using empirical coefficients or fitting parameters. 35 refs., 7 figs., 1 tab

  10. Contribution of non-traditional lipid profiles to reduced glomerular filtration rate in H-type hypertension population of rural China.

    Science.gov (United States)

    Wang, Haoyu; Li, Zhao; Guo, Xiaofan; Chen, Yintao; Chen, Shuang; Tian, Yichen; Sun, Yingxian

    2018-05-01

    Despite current interest in the unfavourable impact of non-traditional lipid profiles on cardiovascular disease, information regarding its relations to reduced glomerular filtration rate (GFR) in H-type hypertension population has not been systemically elucidated. Analyses were based upon a cross-sectional study of 3259 participants with H-type hypertension who underwent assessment of biochemical, anthropometric and blood pressure values. Reduced GFR was considered if meeting estimated GFR <60 ml/min/1.73 m 2 . A stepwise multivariate regression analysis indicated that non-traditional lipid parameters remained as independent determinants of estimated GFR (all p < .001). In multivariable models, we observed a 50%, 51%, 31%, and 24% higher risk for decreased GFR with each SD increment in TC/HDL-C, TG/HDL-C, LDL-C/HDL-C ratios and non-HDL-C levels, respectively. The highest quartile of TC/HDL-C, TG/HDL-C and LDL-C/HDL-C ratios carried reduced GFR odds (confidence intervals) of 5.50 (2.50 to 12.09), 6.63 (2.58 to 17.05) and 2.22 (1.15 to 4.29), respectively. The relative independent contribution of non-traditional lipid profiles, as indexed by TC/HDL-C, TG/HDL-C, LDL-C/HDL-C ratios and non-HDL-C, towards reduced GFR putting research evidence at the very heart of lipoprotein-mediated renal injury set a vital example for applying a clinical and public health recommendation for reducing the burden of chronic kidney disease. KEY MESSAGES Non-traditional lipid profiles has been linked with the occurrence of cardiovascular disease, but none of the studies that address the effect of non-traditional lipid profiles on reduced GFR risk in H-type hypertension population has been specifically established. A greater emphasis of this study resided in the intrinsic value of TC/HDL-C, TG/HDL-C, LDL-C/HDL-C ratios and non-HDL-C that integrate atherogenic and anti-atherogenic lipid molecules to predict the risk of reduced GFR among H-type hypertension population and provide

  11. Changes in estimated glomerular filtration rate over time in South African HIV-1-infected patients receiving tenofovir: a retrospective cohort study

    Science.gov (United States)

    De Waal, Reneé; Cohen, Karen; Fox, Matthew P; Stinson, Kathryn; Maartens, Gary; Boulle, Andrew; Igumbor, Ehimario U; Davies, Mary-Ann

    2017-01-01

    Abstract Introduction: Tenofovir has been associated with decline in kidney function, but in patients with low baseline kidney function, improvements over time have been reported. Additionally, the magnitude and trajectory of estimated glomerular filtration rate (eGFR) changes may differ according to how eGFR is calculated. We described changes in eGFR over time, and the incidence of, and risk factors for, kidney toxicity, in a South African cohort. Methods: We included antiretroviral-naïve patients ≥16 years old who started tenofovir-containing antiretroviral therapy (ART) between 2002 and 2013. We calculated eGFR using the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), and Cockcroft-Gault equations. We described changes in eGFR from ART initiation using linear mixed effects regression. We described the incidence of eGFR <30 mL/min on treatment, and identified associations with low eGFR using Cox regression. Results: We included 15156 patients with median age of 35.4 years (IQR 29.9–42.0), median CD4 cell count of 168 cells/µL (IQR 83–243), and median eGFR (MDRD) of 98.6 mL/min (IQR 84.4–115.6). Median duration of follow up on tenofovir was 12.9 months (IQR 5.1–23.3). Amongst those with a baseline and subsequent eGFR  available, mean eGFR change from baseline at 12 months was −4.4 mL/min (95% CI −4.9 to −4.0), −2.3 (−2.5 to −2.1), and 0.6 (0.04 to 1.2) in those with baseline eGFR ≥90 mL/min; and 11.9 mL/min (11.0 to 12.7), 14.6 (13.5 to 15.7), and 11.0 (10.3 to 11.7) in those with baseline eGFR <90 mL/min, according to the MDRD, CKD-EPI (n = 11 112), and Cockcroft-Gault (n = 9 283) equations, respectively. Overall, 292 (1.9%) patients developed eGFR <30 mL/min. Significant associations with low eGFR included older age, baseline eGFR <60 mL/min, CD4 count <200 cells/µL, body weight <60 kg, and concomitant protease inhibitor use. Conclusions: Patients on

  12. Individualizing pharmacotherapy in patients with renal impairment: the validity of the Modification of Diet in Renal Disease formula in specific patient populations with a glomerular filtration rate below 60 ml/min. A systematic review.

    Directory of Open Access Journals (Sweden)

    Willemijn L Eppenga

    Full Text Available The Modification of Diet in Renal Disease (MDRD formula is widely used in clinical practice to assess the correct drug dose. This formula is based on serum creatinine levels which might be influenced by chronic diseases itself or the effects of the chronic diseases. We conducted a systematic review to determine the validity of the MDRD formula in specific patient populations with renal impairment: elderly, hospitalized and obese patients, patients with cardiovascular disease, cancer, chronic respiratory diseases, diabetes mellitus, liver cirrhosis and human immunodeficiency virus.We searched for articles in Pubmed published from January 1999 through January 2014. Selection criteria were (1 patients with a glomerular filtration rate (GFR < 60 ml/min (/1.73 m2, (2 MDRD formula compared with a gold standard and (3 statistical analysis focused on bias, precision and/or accuracy. Data extraction was done by the first author and checked by a second author. A bias of 20% or less, a precision of 30% or less and an accuracy expressed as P30% of 80% or higher were indicators of the validity of the MDRD formula. In total we included 27 studies. The number of patients included ranged from 8 to 1831. The gold standard and measurement method used varied across the studies. For none of the specific patient populations the studies provided sufficient evidence of validity of the MDRD formula regarding the three parameters. For patients with diabetes mellitus and liver cirrhosis, hospitalized patients and elderly with moderate to severe renal impairment we concluded that the MDRD formula is not valid. Limitations of the review are the lack of considering the method of measuring serum creatinine levels and the type of gold standard used.In several specific patient populations with renal impairment the use of the MDRD formula is not valid or has uncertain validity.

  13. Measuring heart rate with optical sensor

    NARCIS (Netherlands)

    Barachi, M. (Mitra)

    2014-01-01

    The problem addressed in this report is to verify the possibility of using an optical sensor in the SaxShirt in order to extract the heart rate. There are specifically three questions that we try to address. 1) How is it possible to extract heart rate (BPM) from the optical sensor? 2) Is it

  14. PROBLEMS OF NONSTATIONARY FILTRATION

    Directory of Open Access Journals (Sweden)

    Vsevolod A. Shabanov

    2018-03-01

    Full Text Available he article deals with the classical hydrodynamic theory of filtration. Discusses models of soil, fluid and nature of fluid flow that formed the basis for the creation of the classic filtration theory. Also discusses the assumptions made for the linearization of the equations. Evaluated the scope of the classical filtration theory. Proposed a new model of filtration through a porous medium, based on the application of the laws of theoretical mechanics. It is based on the classical model of soil: the soil is composed of capillaries with ..parallel axes, in which the liquid moves. For tasks of infiltration equations of motion. Considered special cases of unsteady motion of a finite volume of liquid. Numerical example a machine experiment.

  15. Filtration in Porous Media

    DEFF Research Database (Denmark)

    Yuan, Hao; Shapiro, Alexander

    There is a considerable and ongoing effort aimed at understanding the transport and the deposition of suspended particles in porous media, especially non-Fickian transport and non-exponential deposition of particles. In this work, the influential parameters in filtration models are studied...... to understand their effects on the non-Fickian transport and the non-exponential deposition. The filtration models are validated by the comparisons between the modelling results and the experimental data.The elliptic equation with distributed filtration coefficients may be applied to model non-Fickian transport...... and hyperexponential deposition. The filtration model accounting for the migration of surface associated particles may be applied for non-monotonic deposition....

  16. Water Filtration Products

    Science.gov (United States)

    1986-01-01

    American Water Corporation manufactures water filtration products which incorporate technology originally developed for manned space operations. The formula involves granular activated charcoal and other ingredients, and removes substances by catalytic reactions, mechanical filtration, and absorption. Details are proprietary. A NASA literature search contributed to development of the compound. The technology is being extended to a deodorizing compound called Biofresh which traps gas and moisture inside the unit. Further applications are anticipated.

  17. Measurements of Protein Crystal Face Growth Rates

    Science.gov (United States)

    Gorti, S.

    2014-01-01

    Protein crystal growth rates will be determined for several hyperthermophile proteins.; The growth rates will be assessed using available theoretical models, including kinetic roughening.; If/when kinetic roughening supersaturations are established, determinations of protein crystal quality over a range of supersaturations will also be assessed.; The results of our ground based effort may well address the existence of a correlation between fundamental growth mechanisms and protein crystal quality.

  18. Laboratory Measures of Filtration by Freshwater Mussels: An Activity to Introduce Biology Students to an Increasingly Threatened Group of Organisms

    Science.gov (United States)

    Smith, Michael J.; Shaffer, Julie J.; Koupal, Keith D.; Hoback, W. Wyatt

    2012-01-01

    Many aquatic organisms survive by filter feeding from the surrounding water and capturing food particles. We developed a laboratory exercise that allows students to measure the effects of filtering by fresh water mussels on water turbidity. Mussels were acquired from Wards Scientific and exposed to a solution of baker's yeast. Over a period of one…

  19. Demonstration of creep during filtration

    DEFF Research Database (Denmark)

    Christensen, Morten Lykkegaard; Bugge, Thomas Vistisen; Kirchheiner, Anders Løvenbalk

    The classical filtration theory assumes a unique relationship between the local filter cake porosity and the local effective pressure. For a number of compressible materials, it has however been observed that during the consolidation stage this may not be the case. It has been found...... that the production of filtrate also depends on the characteristic time for the filter cake solids to deform. This is formulated in the Terzaghi-Voigt model in which a secondary consolidation is introduced. The secondary consolidation may be visualized by plots of the relative cake deformation (U) v.s. the square...... root of time. Even more clearly it is demonstrated by plotting the liquid pressure at the cake piston interface v.s. the relative deformation (to be shown). The phenomenon of a secondary consolidation processes is in short called creep. Provided that the secondary consolidation rate is of the same...

  20. The effect of filtration on radon daughter atmospheres: Laboratory and field experiments

    International Nuclear Information System (INIS)

    Jonassen, N.; Jensen, B.

    1987-01-01

    Airborne radon daughters may be removed from the air by internal filtration using mechanical or electrofilters. The effect of the filtration may be evaluated in absolute measure by the decrease in the potential alpha energy concentration (or equivalent equilibrium concentration) or relatively by the decrease in the equilibrium factor. The filtration, however, may also change the distribution of airborne radon daughter activity between the unattached and the aerosol-attached state in a way to increase the radiological dose corresponding to a given potential alpha energy concentration. The paper describes a series of laboratory and field experiments which indicate that it is possible by the use of household electrofilters with filtration rates of 2-3 h -1 to lower the radon daughter concentrations to about 20 -30 % and the average radiological dose to about 50-60 % of the value in unfiltered air

  1. Microbial uptake of radiolabeled substrates: estimates of growth rates from time course measurements

    International Nuclear Information System (INIS)

    Li, W.K.W.

    1984-01-01

    The uptake of [ 3 H]glucose and a mixture of 3 H-labeled amino acids was measured, in time course fashion, in planktonic microbial assemblages of the eastern tropical Pacific Ocean. The average generation times of those portions of the assemblages able to utilize these substrates were estimated from a simple exponential growth model. Other workers have independently used this model in its integrated or differential form. A mathematical verification and an experimental demonstration of the equivalence of the two approaches are presented. A study was made of the size distribution of heterotrophic activity, using time course measurements. It was found that the size distribution and the effect of sample filtration before radiolabeling were dependent on time of incubation. In principle, it was possible to ascribe these time dependences to differences in th specific growth rate and initial standing stock of the microbial assemblages. 33 references

  2. Measuring Change with the Rating Scale Model.

    Science.gov (United States)

    Ludlow, Larry H.; And Others

    The Rehabilitation Research and Development Laboratory at the United States Veterans Administration Hines Hospital is engaged in a long-term evaluation of blind rehabilitation. One aspect of the evaluation project focuses on the measurement of attitudes toward blindness. Our aim is to measure changes in attitudes toward blindness from…

  3. Automated Speech Rate Measurement in Dysarthria

    Science.gov (United States)

    Martens, Heidi; Dekens, Tomas; Van Nuffelen, Gwen; Latacz, Lukas; Verhelst, Werner; De Bodt, Marc

    2015-01-01

    Purpose: In this study, a new algorithm for automated determination of speech rate (SR) in dysarthric speech is evaluated. We investigated how reliably the algorithm calculates the SR of dysarthric speech samples when compared with calculation performed by speech-language pathologists. Method: The new algorithm was trained and tested using Dutch…

  4. Measurement of characteristics of exhaust pipe for the system for gas-vapor medium filtration of NPP

    International Nuclear Information System (INIS)

    Kalyakin, S.G.; Tsyganok, A.A.; Taranov, G.S.; Grigor'ev, M.M.

    2004-01-01

    Pilot investigation into the dependence of thermal power of pipe of (air-air heat exchanger) from the flow and temperature of heating air was conducted, temperature fields from top to bottom of the pipe was measured. Experiments were performed in the follow regime parameters: the flow of cold (heated) air is equal to 30 m 2 /h (∼0.01 kg/s), the temperature at the inlet was changed in the ranges of T inl c =28-36 Deg C; the flow of heating air was equal to 30, 90, 150 and 220 m 3 /h (0,01-0.075 kg/s) at the temperature at the inlet T inl h =170, 220 and 280 Deg C. In addition to experiments were conducted at 120 Deg C. At 280 Deg C increase of the flow from 0.01 to 0.02 kg/s is over thermal power approximately by 2 times [ru

  5. Determination of Chlorinated Pesticides and Polychlorinated Biphenyls in Edible Oils and Fats using MSPD Extraction and Freeze Lipids-Filtration Cleanup with GC-ECD Measurement

    International Nuclear Information System (INIS)

    Pla Jauregui, Daniela; Valcarcel Rojas, Lino; Estevez Alvarez, Juan

    2015-01-01

    Persistent organic pollutants (POPs) such as organo chlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) have numerous adverse effects on human health. Although their use have been banned or restricted, residues of these compounds can be found in foods, especially those with high fat content. The purpose of this study was to establish a rapid and simple analytical method for the determination of these compounds in edible oils and fats. Matrix solid-phase dispersion (MSPD) was used for the simultaneous extraction and purification of analytes from samples using an acetonitrile - acetone (19:1, v/v) mixture as eluting solvent. Lipids remaining in the extract were removed by freezing-lipid filtration, prior to analytes re-extraction with n-hexane. The measurement was performed using a gas chromatograph with electron capture detector (GC-ECD). Spiking experiments were carried out to determine the recovery, precision and limits of detection (LODs) of the method. Recoveries were higher than 70% and detection limits were in the range of 20 ng/g to 90 ng/g. These LOD values are lower than the maximum permissible limit which makes this method useful for the purpose intended. This method was successfully applied to the analysis of vegetable oils and butters sampled from the market. (Author)

  6. Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom

    Science.gov (United States)

    Lee, Jong-Woong; Kim, Eun-Soo; Choi, Jiwon; Kweon, Dae Cheol

    2014-02-01

    The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.

  7. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  8. Measuring Transpiration to Regulate Winter Irrigation Rates

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Lisa [Auburn University

    2006-11-08

    Periodic transpiration (monthly sums) in a young loblolly pine plantation between ages 3 and 6 was measured using thermal dissipation probes. Fertilization and fertilization with irrigation were better than irrigation alone in increasing transpiration of young loblolly pines during winter months, apparently because of increased leaf area in fertilized trees. Irrigation alone did not significantly increase transpiration compared with the non-fertilized and non-irrigated control plots.

  9. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Depaoli, D.

    1996-01-01

    This task will investigate the capabilities of magnetic-seeding filtration for the enhanced removal of magnetic and nonmagnetic particulates from liquids. This technology appies to a wide range of liquid wastes, including groundwater, process waters, and tank supernatant. Magnetic-seeding filtration can be used in several aspects of treatment, such as (1) removal of solids, particularly those in the colloidal-size range that are difficult to remove by conventional means; (2) removal of contaminants by precipitation processes; and (3) removal of contaminants by sorption processes

  10. Water filtration using plant xylem.

    Directory of Open Access Journals (Sweden)

    Michael S H Boutilier

    Full Text Available Effective point-of-use devices for providing safe drinking water are urgently needed to reduce the global burden of waterborne disease. Here we show that plant xylem from the sapwood of coniferous trees--a readily available, inexpensive, biodegradable, and disposable material--can remove bacteria from water by simple pressure-driven filtration. Approximately 3 cm(3 of sapwood can filter water at the rate of several liters per day, sufficient to meet the clean drinking water needs of one person. The results demonstrate the potential of plant xylem to address the need for pathogen-free drinking water in developing countries and resource-limited settings.

  11. Water Treatment Technology - Filtration.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on filtration provides instructional materials for six competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: purposes of sedimentation basins and flocculation…

  12. A study of dynamic filtration; Um estudo sobre filtracao dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Girao, Joaquim Helder S [PETROBRAS, Natal, RN (Brazil). Distrito de Perfuracao da Bacia Potiguar. Div. de Tecnicas de Perfuracao

    1990-12-31

    The problems that cause cost increase such as: formation damage and borehole swelling or caving lead us to study the filtration of the liquid part of formation drilling fluid. With the aim of comparing static and dynamic filtration rates, we developed a modest dynamic filtration equipment, consisting of a modified API filter, connected to reservoir by means of a positive injection pump. We carried out various tests, and the results were set in charts and tables. Through these, it is possible to notice how the static and dynamic filtration curves come apart for a same pressure value. We also evaluated the effects of circulation speed, starch concentration and counter pressure. This paper does not include calculations or mathematical models accounting for filtrate invasion radii, but it demonstrates, for example, that cleaning circulation will cause lower filtration rates at lower flows. (author) 5 refs., 11 figs., 14 tabs.

  13. A study of dynamic filtration; Um estudo sobre filtracao dinamica

    Energy Technology Data Exchange (ETDEWEB)

    Girao, Joaquim Helder S. [PETROBRAS, Natal, RN (Brazil). Distrito de Perfuracao da Bacia Potiguar. Div. de Tecnicas de Perfuracao

    1989-12-31

    The problems that cause cost increase such as: formation damage and borehole swelling or caving lead us to study the filtration of the liquid part of formation drilling fluid. With the aim of comparing static and dynamic filtration rates, we developed a modest dynamic filtration equipment, consisting of a modified API filter, connected to reservoir by means of a positive injection pump. We carried out various tests, and the results were set in charts and tables. Through these, it is possible to notice how the static and dynamic filtration curves come apart for a same pressure value. We also evaluated the effects of circulation speed, starch concentration and counter pressure. This paper does not include calculations or mathematical models accounting for filtrate invasion radii, but it demonstrates, for example, that cleaning circulation will cause lower filtration rates at lower flows. (author) 5 refs., 11 figs., 14 tabs.

  14. Filtration of droplets in the nose of the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Davies, C N

    1946-01-01

    Optical measurement was done on oil cloud sedimentation before and after passing through nose and out tracheal cannula. The filtering unit which also provides most resistance to flow is maximal turbinates. Nasal cavity is more complex than in man or some other animals, so filtration may be different. Calculation of particle inertia and filter channel width shows that particles > 7 ..mu..m would impact on curves or projections. Particles less than 1.5 ..mu..m should penetrate freely, but low molecular weight gases would be caught by diffusion. The higher the flow, the better the filtration (inertial settling). Broadly summarizing, at ordinary flow rates and nasal resistances, essentially all drops > 7 ..mu..m will be removed. About 50% of 3-..mu.. drops will be removed. < 1.5-..mu..m drops will penetrate.

  15. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  16. Method of electrostatic filtration

    International Nuclear Information System (INIS)

    Devienne, F.M.

    1975-01-01

    Electrostatic filtration of secondary ions of mass m in a given mass ratio with a primary ion of mass M which has formed the secondary ions by fission is carried out by a method which consists in forming a singly-charged primary ion of the substance having a molecular mass M and extracting the ion at a voltage V 1 with respect to ground. The primary ion crosses a potential barrier V 2 , in producing the dissociation of the ion into at least two fragments of secondary ions and in extracting the fragment ion of mass m at a voltage V 2 . Filtration is carried out in an electrostatic analyzer through which only the ions of energy eV'' are permitted to pass, detecting the ions which have been filtered. The mass m of the ions is such that (M/m) = (V 1 - V 2 )/(V'' - V 2 )

  17. Facility of aerosol filtration

    Energy Technology Data Exchange (ETDEWEB)

    Duverger de Cuy, G; Regnier, J

    1975-04-18

    Said invention relates to a facility of aerosol filtration, particularly of sodium aerosols. Said facility is of special interest for fast reactors where sodium fires involve the possibility of high concentrations of sodium aerosols which soon clog up conventional filters. The facility intended for continuous operation, includes at the pre-filtering stage, means for increasing the size of the aerosol particles and separating clustered particles (cyclone separator).

  18. Mixture based outlier filtration

    Czech Academy of Sciences Publication Activity Database

    Pecherková, Pavla; Nagy, Ivan

    2006-01-01

    Roč. 46, č. 2 (2006), s. 30-35 ISSN 1210-2709 R&D Projects: GA MŠk 1M0572; GA MDS 1F43A/003/120 Institutional research plan: CEZ:AV0Z10750506 Keywords : data filtration * system modelling * mixture models Subject RIV: BD - Theory of Information http://library.utia.cas.cz/prace/20060165.pdf

  19. Detergent zeolite filtration plant

    OpenAIRE

    Stanković Mirjana S.; Pezo Lato L.

    2003-01-01

    The IGPC Engineering Department designed basic projects for detergent zeolite filtration plant, using technology developed in the IGPC laboratories. Several projects were completed: technological, machine, electrical, automation. On the basis of these projects, a production plant with a capacity of 75,000 t/y was manufactured, at "Zeolite Mira", Mira (VE), Italy, in 1997, for increasing detergent zeolite production, from 50,000 to 100,000 t/y. The main goal was to increase the detergent zeoli...

  20. Characterization, Washing, Leaching, and Filtration of C-104 Sludge

    Energy Technology Data Exchange (ETDEWEB)

    KP Brooks; PR Bredt; GR Golcar; SA Hartley; LK Jagoda; KG Rappe; MW Urie

    2000-06-09

    Approximately 1,400 g of wet Hanford Tank C-104 Sludge was evaluated by Battelle for the high-level waste (HLW) pretreatment processes of ultrafiltration, dilute caustic washing, and elevated-temperature caustic leaching. The filterability of diluted C-104 sludge was measured with a 0.1-{micro}m sintered metal Mott filter using a 24-inch-long, single-element, crossflow filtration system (cells unit filter [CUF]). While the filtrate was being recirculated prior to washing and leaching, a 6.9 wt% solids slurry was evaluated with a matrix of seven 1-hour conditions of varying trans-membrane pressure (30 to 70 psid) and axial velocity (9 to 15 ft/s). The filtrate flux and backpulse efficiency were determined for each condition. The slurry was concentrated to 23 wt% solids, a second matrix of six 1-hour conditions was performed, and data analogous to that recorded in the first matrix were obtained. The low-solids-concentration matrix produced filtrate flux rates that ranged from 0.038 to 0.083 gpm/ft{sup 2}. The high-solids-concentration matrix produced filtrate flux rates that ranged from 0.0095 to 0.0172 gpm/ft{sup 2}. In both cases, the optimum filtrate flux was at the highest axial velocity (15 ft/s) and transmembrane pressure had little effect. Nearly all of the measured filtrate fluxes were more than an order of magnitude greater than the required plant flux for C-104 of 0.00126 gpm/ft{sup 2}. In both matrices, the filtrate flux appeared to be proportional to axial velocity, and the permeability appeared to be inversely proportional to the trans-membrane pressure. The first test condition was repeated as the last test condition for each matrix. In both cases, there was a significant decrease in filtrate flux, indicating some filter fouling during the test matrix that could not be removed by backpulsing alone, although the backpulse number and duration were not optimized. Following testing of these two matrices, the material was washed within the CUF by

  1. Eddy-current flow rate meter for measuring sodium flow rates

    International Nuclear Information System (INIS)

    Knaak, J.

    1976-01-01

    For safety reasons flow rate meters for monitoring coolant flow rates are inserted in the core of sodium-cooled fast breeder reactors. These are so-called eddy-current flow rate meters which can be mounted directly above the fuel elements. In the present contribution the principle of measurement, the mechanical construction and the circuit design of the flow rate measuring device are described. Special problems and their solution on developing the measuring system are pointed out. Finally, results of measurement and experience with the apparatus in several experiments are reported, where also further possibilities of application were tested. (orig./TK) [de

  2. Device accurately measures and records low gas-flow rates

    Science.gov (United States)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  3. Radiotracer technique to quantify change in filtration velocity as a measure of dilution effect by artificial recharge in an arsenic infested aquifer at Ashoknagar, Habra - II block, 24 Paragana district, West Bengal

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2004-01-01

    Radioisotopes are frequently employed as tracers for various applications in industry, agricultural, medicine and hydrology. In hydrology, radiotracers are commonly applied to investigate several hydrological parameters of aquifers such as hydraulic conductivity, groundwater velocity and direction of flow etc. They impart valuable insight into the understanding of the hydrological systems. Application of radioisotopes in determination of groundwater flow velocity is now a well established technique. In this paper, groundwater filtration velocity was determined in an arsenic infested alluvium aquifer at Ashoknagar, Habra, West Bengal for determining the dilution effect due to arsenic free water. In some parts of West Bengal, generally shallow aquifers up to 80 m deep are contaminated due to geogenic arsenic. Researchers have different views about origin and mobility of arsenic in the groundwaters of West Bengal. For the removal of Arsenic from the groundwater various methods have been suggested and implemented such as ion-exchange, co-precipitation, adsorption, membrane separation and dilution etc. Dilution of the Arsenic concentration by artificial recharge of arsenic free water from the constructed pits in the contaminated aquifer is one such simple method. Efficacy of this method was studied by measuring filtration velocity in the contaminated aquifer at the Ashoknagar, Habra - II Block, North 24 Paragana district, West Bengal. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater. Point dilution technique in a single well was applied. Filtration velocity provided relevant information about the arsenic dilution in the groundwater by the artificial recharge and its value will be used as a model parameter. (author)

  4. Resistive Wall Growth Rate Measurements in the Fermilab Recycler

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, R. [Fermilab; Adamson, P. [Fermilab; Burov, A. [Fermilab; Kourbanis, I. [Fermilab

    2016-10-05

    Impedance could represent a limitation of running high intensity beams in the Fermilab recycler. With high intensity upgrades foreseen, it is important to quantify the impedance. To do this,studies have been performed measuring the growth rate of presumably the resistive wall instability. The growth rates at varying intensities and chromaticities are shown. The measured growth rates are compared to ones calculated with the resistive wall impedance.

  5. In-Water Hull Cleaning & Filtration System

    Science.gov (United States)

    George, Dan

    2015-04-01

    Dan George R & D Mining Technology LinkedIn GRD Franmarine have received the following prestigious awards in 2014 for their research & development of an in-water hull cleaning and filtration system "The Envirocart: Golden Gecko Award for Environmental Excellence; WA Innovator of the Year - Growth Sector; Department of Fisheries - Excellence in Marine Biosecurity Award - Innovation Category; Lloyd's List Asia Awards - Environmental Award; The Australian Innovation Challenge - Environment, Agriculture and Food Category; and Australian Shipping and Maritime Industry Award - Environmental Transport Award. The Envirocart developed and patented by GRD Franmarine is a revolutionary new fully enclosed capture and containment in-water hull cleaning technology. The Envirocart enables soft Silicon based antifouling paints and coatings containing pesticides such as Copper Oxide to be cleaned in situ using a contactless cleaning method. This fully containerised system is now capable of being deployed to remote locations or directly onto a Dive Support Vessel and is rated to offshore specifications. This is the only known method of in-water hull cleaning that complies with the Department of Agriculture Fisheries and Forestry (DAFF) and Department of Fisheries WA (DoF) Guidelines. The primary underwater cleaning tool is a hydraulically powered hull cleaning unit fitted with rotating discs. The discs can be fitted with conventional brushes for glass or epoxy based coatings or a revolutionary new patented blade system which can remove marine biofouling without damaging the antifouling paint (silicone and copper oxide). Additionally there are a patented range of fully enclosed hand cleaning tools for difficult to access niche areas such as anodes and sea chests, providing an innovative total solution that enables in-water cleaning to be conducted in a manner that causes no biological risk to the environment. In full containment mode or when AIS are present, material is pumped

  6. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  7. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  8. Determination of Glomerular Filtration Rate with {sup 51}Cr, {sup 58}Co, {sup 114m}In, {sup 115m}In and {sup 169}Yb- Labelled EDTA and DTPA Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, Gy.; Pal, I.; Stuetzel, M.; Jaky, L. [Third Department of Medicine, University Medical School and Institute of Isotopes of the Hungarian Academy of Sciences, Budapest (Hungary)

    1971-02-15

    Some metal complexes are suitable for determination of the glomerular filtration rate (GFR). A series of labelled EDTA and DTPA complexes have been produced during the last two years by the Isotope Institute of the Hungarian Academy of Sciences. The common property of EDTA and DTPA complexes is their great stability, which is a major advantage over the iodinated compounds. We have demonstrated that none of the complexes used by us combine with plasma proteins or penetrate into the red blood cells. There is evidence that EDTA and DTPA leave the body exclusively by way of glomerular filtration. The results of more than 600 cases are presented. {sup 169}Yb EDTA was used in 315, {sup 51}Cr EDTA in 126, {sup 114m}In EDTA in 83, {sup 58}Co DTPA in 72 and {sup 115m}In EDTA in 28 cases for determination of GFR. The injected activity was 0.3 -4.0 {mu}Ci/kg body weight. In most cases the result has been compared with the 24-h endogenous creatine clearance, and in 50 cases with inulin clearance also. In general the single-shot method was used. Blood samples were taken about the first and the second hour after injection of the isotope. A formula is given for calculating GFR. In a few cases we administered the isotope in the same way as inulin (priming dose and constant plasma concentration sustained by an infusion pump). Our results show that the single-shot method is a very suitable one in routine clinical practice either in states of normal or reduced kidney function. Using the single-shot method for GFR determination is especially important in those cases where the collection of urine is impossible without using a catheter, which always entails the risk of infection. Results are reliable even in disorders of the urinary tract. During or after the procedure no side effects could be observed. (author)

  9. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  10. Drug Dosing in Patients with Renal Insufficiency in a Hospital Setting using Electronic Prescribing and Automated Reporting of Estimated Glomerular Filtration Rate

    DEFF Research Database (Denmark)

    Nielsen, Anita L.; Henriksen, Daniel Pilsgaard; Marinakis, Christianna

    2014-01-01

    In patients with impaired renal function, drug dose adjustment is often required. Non-adherence to clinical prescribing recommendations may result in severe adverse events. In previous studies, the prevalence rate of non-adherence to recommended dosing has been reported to be 19-67%. Using the cl...... decision support systems should be explored. This article is protected by copyright. All rights reserved....

  11. Field Demonstration of Fuel Crud Filtration System at Ulchin Plant

    International Nuclear Information System (INIS)

    Kang, Duk-Won; Lee, Doo-Ho; Park, Jong-Youl; Choi, In-Kyu

    2007-01-01

    Crud deposited onto the fuel assemblies in nuclear power plants was not a serious problem until an upper core flux depression named Axial Offset Anomaly (AOA) was found at Callaway, USA in 1989. Though the mechanism of an AOA is not completely understood, crud is believed to be a key component of initiating AOA. After the sufficient amount of corrosion products in the reactor cooling system are deposited on the fuel clad by a sub-cooled nucleate boiling, boron is adsorbed in the crud. Thus a measurable reduction in the neutron flux occurs which causes an AOA problem. A filtration system has been developed to remove the fuel crud from irradiated fuel assemblies for mitigating the axial offset anomaly under a technical cooperation agreement with DEI (Dominion Engineering Inc.). This filtration system with a fuel cleaning fixture was successfully demonstrated at Ulchin plant unit 2. Within several minutes, detachable crud deposits were effectively removed from the clad surfaces of the fuel assembly. Also, to characterize the crud particles for each fuel assembly, a small crud sampling device and radiation monitor devices were connected to the filtration system during the cleaning operation. In this study, we completed a functional test and demonstration of an ultrasonic fuel cleaning system by using four spent fuel assemblies. It took only 5 minutes to remove the fuel crud from each fuel assembly. In addition, collective dose rates indicated an average of 8 R/Hr per assembly

  12. Differential effect of T-type voltage-gated calcium channel disruption on renal plasma flow and glomerular filtration rate in vivo

    DEFF Research Database (Denmark)

    Thuesen, Anne D; Andersen, Henrik; Cardel, Majken

    2014-01-01

    Voltage-gated calcium channels (Cav) play an essential role in regulation of renal blood flow and GFR. Because T-type Cavs are differentially expressed in pre- and postglomerular vessels it was hypothesized that they impact renal blood flow and GFR differentially. The question was addressed by use...... of two T-type Cav knock-out mice strains. Continuous recordings of blood pressure and heart rate, and para-aminohippurate clearance (renal plasma flow) and inulin clearance (GFR) were performed in conscious, chronically catheterized, wild type and Cav 3.1-/- and Cav 3.2-/- mice. Contractility of afferent...... and efferent arterioles was determined in isolated perfused blood vessels. Efferent arterioles from Cav 3.2-/- mice constricted significantly more in response to a depolarization compared to Wt mice. GFR was increased in Cav 3.2-/- mice with no significant changes in renal plasma flow, heart rate and blood...

  13. Fission rate measurements in fuel plate type assembly reactor cores

    International Nuclear Information System (INIS)

    Rogers, J.W.

    1988-01-01

    The methods, materials and equipment have been developed to allow extensive and precise measurement of fission rate distributions in water moderated, U-Al fuel plate assembly type reactor cores. Fission rate monitors are accurately positioned in the reactor core, the reactor is operated at a low power for a short time, the fission rate monitors are counted with detectors incorporating automated sample changers and the measurements are converted to fission rate distributions. These measured fission rate distributions have been successfully used as baseline information related to the operation of test and experimental reactors with respect to fission power and distribution, fuel loading and fission experiments for approximately twenty years at the Idaho National Engineering Laboratory (INEL). 7 refs., 8 figs

  14. Sodium flow rate measurement method of annular linear induction pump

    International Nuclear Information System (INIS)

    Araseki, Hideo

    2011-01-01

    This report describes a method for measuring sodium flow rate of annular linear induction pumps arranged in parallel and its verification result obtained through an experiment and a numerical analysis. In the method, the leaked magnetic field is measured with measuring coils at the stator end on the outlet side and is correlated with the sodium flow rate. The experimental data and the numerical result indicate that the leaked magnetic field at the stator edge keeps almost constant when the sodium flow rate changes and that the leaked magnetic field change arising from the flow rate change is small compared with the overall leaked magnetic field. It is shown that the correlation between the leaked magnetic field and the sodium flow rate is almost linear due to this feature of the leaked magnetic field, which indicates the applicability of the method to small-scale annular linear induction pumps. (author)

  15. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  16. Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Johnson, Thorsten R.C.; Sommer, Wieland H.; Thierfelder, Kolja M.; Meinel, Felix G. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-06-01

    To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDI{sub vol}, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. (orig.)

  17. Absolute rate measurement by light modulation - ESR technique

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K Y; Gaspar, P P

    1977-01-01

    A rate constant is deduced for the reaction of tert-butoxy radicals and trimethylsilane from the measurement of the phase shift between the modulated light source and the ESR signal of trimethylsilyl radical. The rate constant was found to be 3 x 10/sup -2/M/sup -1/. sec/sup -1/ at -50/sup 0/C.

  18. Health Benefits of Particle Filtration

    OpenAIRE

    Fisk, William J.

    2013-01-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and as...

  19. Neutrons production of very low energy by filtration through graphite and measurement of total cross sections; Production de neutrons de tres basse energie par filtration a travers du graphite et mesure de sections efficaces totales

    Energy Technology Data Exchange (ETDEWEB)

    Ertaud, A; Beauge, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-07-01

    In this report, we done on the reactor of Chatillon analogous experiences to those of Fermi in Argonne. The temperature of the neutrons filtered ba a more or less thickness of graphite is measured by the method of absorption. This method permits the production and the study of a very low energy neutron beam. (M.B.) [French] Dans ce rapport, nous avons repris sur la pile de Chatillon des experiences analogues a celles de FERMI a Argonne. La temperature des neutrons filtree par une epaisseur plus ou moins grande de graphite est mesuree par la methode d'absorption. Cette methode permettant la production et l'etude d'un faisceau de neutron de tres basse energie. (M.B.)

  20. Estimating glomerular filtration rate using the new CKD-EPI equation and other equations in patients with autosomal dominant polycystic kidney disease

    DEFF Research Database (Denmark)

    Orskov, Bjarne; Borresen, Malene L; Feldt-Rasmussen, Bo

    2010-01-01

    (CKD-EPI) equation, the Cockcroft-Gault equation adjusted for body surface area and the MDRD equation with cystatin C. Performance was evaluated by mean bias, precision and accuracy. RESULTS: The MDRD equation with cystatin C had 97% of GFR estimates within 30% of measured GFR (accuracy). Both the CKD-EPI....... The CKD-EPI or the Cockcroft-Gault equations showed better performance compared to the 4-variable MDRD equation....

  1. Immobilized Filters for Air Filtration

    National Research Council Canada - National Science Library

    Mahle, John J; Zaiee, Saeed

    2002-01-01

    ... (settling performance) and attrition resistance. The fabricated filter samples will be analyzed in order to determine the physical and chemical factors affecting mechanical strength and chemical filtration...

  2. Measurement of flow rate in the third loop of PWR

    International Nuclear Information System (INIS)

    Gao Shufan.

    1986-01-01

    The range of flow rate was 14000-50000 m 3 /h. The diameter of main tube was 2.6 m. A special made pitot set was placed on the main tube in order to accurately measure the flow rate. A cross slideway and a guide devicc were used to prevent the pitot vibration. Method of equal annular area was used in the measurement. The error was less than 4.2%. A pitot cylinder flowmeter was set also on the main tube to supervise the total flow rate of the third loop

  3. Assessment of salivary flow rate: biologic variation and measure error.

    NARCIS (Netherlands)

    Jongerius, P.H.; Limbeek, J. van; Rotteveel, J.J.

    2004-01-01

    OBJECTIVE: To investigate the applicability of the swab method in the measurement of salivary flow rate in multiple-handicap drooling children. To quantify the measurement error of the procedure and the biologic variation in the population. STUDY DESIGN: Cohort study. METHODS: In a repeated

  4. The Perspective of Riverbank Filtration in China

    Science.gov (United States)

    Li, J.; Teng, Y.; Zhai, Y.; Zuo, R.

    2014-12-01

    Sustainable drinking water supply can affect the health of people, and the surrounding ecosystems. According to statistics of the monitoring program of drinking water sources in 309 at or above prefecture level of China in 2013, the major pollutants index were total phosphorus, ammonia and manganese in surface drinking water sources, respectively, iron, ammonia and manganese in groundwater drinking water sources, respectively. More than 150 drinking water emergency environmental accidents happened since 2006, 52 of these accidents led to the disruption of water supply in waterworks, and a population of over ten million were affected. It indicated that there is a potential risk for people's health by the use of river water directly and it is necessary to require alternative techniques such as riverbank filtration for improving the drinking water quality. Riverbank filtration is an inexpensive natural process, not only smoothing out normal pollutant concentration found in surface water but also significantly reducing the risk from such emergency events as chemical spill into the river. Riverbank filtration technique has been used in many countries more than 100 years, including China. In China, in 1950s, the bank infiltration technique was first applied in northeast of China. Extensive bank infiltration application was conducted in 1980s, and more than 300 drinking water sources utilities bank infiltration established mainly near the Songhua River Basin, the Yellow River Basin, Haihe River Basin. However, the comparative lack of application and researches on riverbank filtration have formed critical scientific data gap in China. As the performance of riverbank filtration technique depend on not only the design and setting such as well type, pumping rate, but also the local hydrogeology and environmental properties. We recommend more riverbank filtration project and studies to be conducted to collect related significant environmental geology data in China

  5. Salt disposition alternatives filtration at SRTC

    International Nuclear Information System (INIS)

    Walker, B. W.; Hobbs, D.

    2000-01-01

    Several of the prospective salt disposition alternative technologies require a monosodium titanate (MST) contact to remove strontium and actinides from inorganic salt solution feedstock. This feedstock also contains sludge solids from waste removal operations and may contain defoamers added in the evaporator systems. Filtration is required to remove the sludge and MST solids before sending the salt solution for further processing. This report describes testing performed using the Parallel Theological Experimental Filter (PREF). The PREF contains two single tube Mott sintered metal crossflow filters. For this test one filter was isolated so that the maximum velocities could be achieved. Previous studies showed slurries of MST and sludge in the presence of sodium tetraphenylborate (NaTPB) were filterable since the NaTPB slurry formed a filter cake which aided in removing the smaller MST and sludge particles. Some of the salt disposition alternative technologies do not use NaTPB raising the question of how effective crossflow filtration is with a feed stream containing only sludge and MST. Variables investigated included axial velocity, transmembrane pressure, defoamer effects, and solids concentration (MST and sludge). Details of the tests are outlined in the technical report WSRC-RP-98-O0691. Key conclusions from this study are: (1) Severe fouling of the Mott sintered metal filter did not occur with any of the solutions filtered. (2) The highest fluxes, in the range of .46 to 1.02 gpm/f 2 , were obtained when salt solution decanted from settled solids was fed to the filter. These fluxes would achieve 92 to 204 gpm filtrate production for the current ITP filters. The filtrate fluxes were close to the flux of 0.42 gpm/f 2 reported for In Tank Precipitation Salt Solution by Morrisey. (3) For the range of solids loading studied, the filter flux ranged from .04 to .17 gpm/f 2 which would result in a filtrate production rate of 9 to 31 gpm for the current HP filter. (4

  6. QT measurement and heart rate correction during hypoglycemia

    DEFF Research Database (Denmark)

    Christensen, Toke Folke; Randløv, Jette; Christensen, Leif Engmann

    2010-01-01

    induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett's (QTcB) and Fridericia's (QTcF) formulas. Results. The SI method showed significant......Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia...... prolongation at hypoglycemia for QTcB (42(6) ms; P measuring the QT interval has...

  7. Measuring Outdoor Air Intake Rates into Existing Building

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  8. Associations of blood lead, cadmium, and mercury with estimated glomerular filtration rate in the Korean general population: Analysis of 2008–2010 Korean National Health and Nutrition Examination Survey data

    International Nuclear Information System (INIS)

    Kim, Yangho; Lee, Byung-Kook

    2012-01-01

    Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008–2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium and mercury, the difference in eGFR levels associated with doubling of blood lead were −2.624 mL/min per 1.73 m² (95% CI: −3.803 to −1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was −3.835 mL/min per 1.73 m² (95% CI: −5.730 to −1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 μg/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.

  9. Associations of blood lead, cadmium, and mercury with estimated glomerular filtration rate in the Korean general population: Analysis of 2008-2010 Korean National Health and Nutrition Examination Survey data

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yangho [Department of Occupational and Environmental Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan (Korea, Republic of); Lee, Byung-Kook, E-mail: bklee@sch.ac.kr [Institute of Environmental and Occupational Medicine, Soonchunhyang University 646 Eupnae-ri, Shinchang-myun, Asan-si, Choongnam 336-745 (Korea, Republic of)

    2012-10-15

    Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008-2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium and mercury, the difference in eGFR levels associated with doubling of blood lead were -2.624 mL/min per 1.73 m Superscript-Two (95% CI: -3.803 to -1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was -3.835 mL/min per 1.73 m Superscript-Two (95% CI: -5.730 to -1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 {mu}g/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.

  10. Differences between nisoldipine and lisinopril on glomerular filtration rates and albuminuria in hypertensive IDDM patients with diabetic nephropathy during the first year of treatment

    DEFF Research Database (Denmark)

    Rossing, P; Tarnow, L; Boelskifte, S

    1997-01-01

    were required in 10 nisoldipine- and 8 lisinopril-treated patients. Every 3 months, 24-h ambulatory blood pressure (TM2420, A&D, Tokyo, Japan) and albuminuria in three 24-h samples (enzyme immunoassay) were measured; GFR (51Cr-EDTA plasma clearance) was recorded every 6 months. Mean arterial blood......-blind, double-dummy, randomized, controlled study comparing nisoldipine (20-40 mg once daily) with lisinopril (10-20 mg once daily) in 52 hypertensive IDDM subjects with diabetic nephropathy. Three patients dropped out, and results for the remaining 49 (25 nisoldipine, 24 lisinopril) are presented. Diuretics...... pressure (24 h) was reduced from (mean +/- SE) 108 +/- 3 mmHg at baseline to 101 +/- 2 in average during treatment in the lisinopril group and from 105 +/- 2 to 103 +/- 2 in the nisoldipine group (P = 0.06 comparing changes in the two groups). Albuminuria was reduced 47% (95% CI 21-65) in the lisinopril...

  11. Accuracy of real time radiography burning rate measurement

    Science.gov (United States)

    Olaniyi, Bisola

    The design of a solid propellant rocket motor requires the determination of a propellant's burning-rate and its dependency upon environmental parameters. The requirement that the burning-rate be physically measured, establishes the need for methods and equipment to obtain such data. A literature review reveals that no measurement has provided the desired burning rate accuracy. In the current study, flash x-ray modeling and digitized film-density data were employed to predict motor-port area to length ratio. The pre-fired port-areas and base burning rate were within 2.5% and 1.2% of their known values, respectively. To verify the accuracy of the method, a continuous x-ray and a solid propellant rocket motor model (Plexiglas cylinder) were used. The solid propellant motor model was translated laterally through a real-time radiography system at different speeds simulating different burning rates. X-ray images were captured and the burning-rate was then determined. The measured burning rate was within 1.65% of the known values.

  12. Validating a new device for measuring tear evaporation rates.

    Science.gov (United States)

    Rohit, Athira; Ehrmann, Klaus; Naduvilath, Thomas; Willcox, Mark; Stapleton, Fiona

    2014-01-01

    To calibrate and validate a commercially available dermatology instrument to measure tear evaporation rate of contact lens wearers. A dermatology instrument was modified by attaching a swim goggle cup such that the cup sealed around the eye socket. Results for the unmodified instrument are dependent on probe area and enclosed volume. Calibration curves were established using a model eye, to account for individual variations in chamber volume and exposed area. Fifteen participants were recruited and the study included a contact lens wear and a no contact lens wear stage. Day and diurnal variation of the measurements were assessed by taking the measurement three times a day over 2 days. The coefficient of repeatability of the measurement was calculated and a linear mixed model assessed the influence of humidity, temperature, contact lens wear, day and diurnal variations on tear evaporation rate. The associations between variables were assessed using Pearson correlation coefficient. Absolute evaporation rates with and without contact lens wear were calculated based on the new calibration. The measurements were most repeatable during the evening with no lens wear (COR = 49 g m⁻² h) and least repeatable during the evening with contact lens wear (COR = 93 g m⁻² h). Humidity (p = 0.007), and contact lens wear (p evaporation rate. However, temperature (p = 0.54) diurnal variation (p = 0.85) and different days (p = 0.65) had no significant effect after controlling for humidity. Tear evaporation rates can be measured using a modified dermatology instrument. Measurements were higher and more variable with lens wear consistent with previous literature. Control of environmental conditions is important as a higher humidity results in a reduced evaporation rate. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  13. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  14. Effect of low glomerular filtration rate on evaluating the cardiac function by N-terminal pro-brain natriuretic peptide in patients with hypertension

    International Nuclear Information System (INIS)

    Wang Lili; Li Peiyong; Guan Liang

    2013-01-01

    Objective: To assess the diagnostic accuracy of NT-proBNP in hypertension patients by observing the effect of decreased GFR on N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration in patients with different cardiac function. Methods: Eighty-nine hypertension patients were divided into two groups based on the results of UCG. Forty-three patients had normal left ventricular function and 46 patients had dysfunction. GFR, NT-proBNP and other biochemical markers of cardiac and renal function were measured. The factors affecting the NT-proBNP concentration under normal left ventricular function were analyzed, and the diagnostic value of NT-proBNP affected by normal or decreased GFR (> 80 ml/min or ≤80 ml/min) under different left ventricular functions were further assessed. The two-sample t test, rank sum test and multiple regression analysis were used to analyze their statistical difference and relationship. Results: In patients with normal left ventricular function, GFR (β=-0.361, P<0.05) and left ventricular end-diastolic diameter (LVEDD, β=0.385, P<0.05) were significant factors to NT-proBNP level. They were both meaningful compared with LVEF (β=0.189, P>0.05) and septal thickness (β=0.003, P>0.05). The median concentration of NT-proBNP was 13.18 and 24.14 μg/L in patients with normal left ventricular function and dysfunction, respectively (Z=-3.19, P<0.01). While in patients with decreased GFR, 6 cases with normal left ventricular function and 19 cases with dysfunction had a median concentration of NT-proBNP of 38.45 and 44.20 μg/L, respectively (Z=-0.45, P>0.05). In patients with normal GFR, 37 cases with normal left ventricular function and 27 cases with dysfunction had a median concentration of NT-proBNP of 12.51 and 20.31 μg/L, which was lower than that of patients with decreased GFR (Z=-2.76, both P<0.05). The NT-proBNP concentration had no significant difference between patients of normal left ventricular function with decreased GFR and

  15. 40 CFR 141.173 - Filtration.

    Science.gov (United States)

    2010-07-01

    ... PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.173 Filtration. A public water system subject to the requirements of this subpart that does... treatment, direct filtration, slow sand filtration, or diatomaceous earth filtration. A public water system...

  16. Measurement of viscosity of slush at high shear rates

    OpenAIRE

    小林, 俊一; 川村, 公之; 津川, 圭一; 和泉, 薫; Kobayashi, Shun'ichi; Kawamura, Kimiyuki; Tugawa, Keiichi; Izumi, Kaoru

    1988-01-01

    Measurements of viscosity of slush were carried out using a method of flow along an inclined smooth surface in a 0℃cold room. The method was used to get the values of viscosity under high shear rates (25 and 75s^). From our experiments two important results were obtained: 1) the viscosity of slush decreases with increasing shear rates; 2) The fluid behavior is pseudoplastic that the values of non-Newtonian index of viscosity were less than unity.

  17. Evaluation of Impact of Coagulant Type on Operation Parameters in Direct Filtration

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2007-06-01

    Full Text Available Numerous advantages have been reported on PAC (poly aluminum chloride used as a coagulant over other coagulants such as alum and ferric chloride used in conventional water treatment process with medium and high turbidity levels. These include lower amounts of PACL required specially in removing turbidity, larger floc grain formation, reduced floc sedimentation time, lower sludge production, and relaxation of the need for pH adjustment by lime, among others. The present study aims to evaluate the effects of different coagulants such as ferric chloride and PACL on direct filtration and to identify the most effective material based on both turbidity and particle removal efficiencies. A perfectly experimental pilot system, including raw water preparation, coagulation, flocculation, distribution measurement, and filtration units, was designed and used. Raw water turbidity level in the experimental pilot was below 10 NTU. The effects of various parameters such as coagulant type, filtration rate, and coagulant dosage on the performance of the filter were investigated. The results obtained from several filtration cycles under different conditions indicated that average effluent turbidity level, effluent particle numbers, effluent turbidity variation graph, and effluent particle graph were lower throughout the filtration cycle when PACL was used compared to when ferric chloride was used as the coagulant. Increasing filtration rate led to increased turbidity and particle number. Addition of 2 mg/l of PACL (poor coagulation and flocculation scenario was compared with addition of 5 mg/l of ferric chloride (strong coagulation and flocculation scenario. The results indicated that higher average values of turbidity removal but lower turbidity and particle removal efficiencies obtained in the case of the poor coagulation and flocculation scenario.

  18. Efficient filtration system for paraffin-catalyst slurry separation

    Directory of Open Access Journals (Sweden)

    Khodagholi Mohammad Ali

    2013-01-01

    Full Text Available The filtration efficiency for separating liquid paraffin (or water from a slurry consisting of 25 weight% spherical alumina in a Slurry Bubble Column Reactor (SBCR comprised of a cylindrical tube of 10 cm diameter and 150 cm length was studied. Various differential pressures (ΔP were applied to two separate tubular sintered metal stainless steel filter elements with nominal pore size of 4 and 16μm. The experimental results disclosed that the rate of filtrations increased on applying higher differential pressure to the filter element. Albeit this phenomenon is limited to moderate ΔPs and for ΔP more than 1 bar is neither harmful nor helpful. The highest filtration rates at ΔPs higher than 1 bar were 170 and 248 ml/minute for 4 and 16μm respectively. Using water as the liquid in slurry the rate of filtration enhanced to 4 folds, and this issue reveals impact of viscosity on filtration efficiency clearly. In all situations, the total amount of particles present in the filtrate part never exceeded a few parts per million (ppm. The statistical analysis of the SEM image of the filtrate indicated that by applying higher pressure difference to the filter element the frequency percent of larger particle size increases. The operation of filter cake removing was performed with back flashing of 300 ml of clean liquid with pressures of 3-5 bar of N2 gas.

  19. Assessment of glomerular filtration rate based on alterations of serum brain-derived neurotrophic factor in type 2 diabetic subjects treated with amlodipine/benazepril or valsartan/hydrochlorothiazide.

    Science.gov (United States)

    Lee, I-Te; Sheu, Wayne Huey-Herng; Hung, Yi-Jen; Chen, Jung-Fu; Wang, Chih-Yuan; Lee, Wen-Jane

    2015-01-01

    Brain-derived neurotrophic factor (BDNF) is associated with sympathetic activation. However, the effects of BDNF on diabetic nephropathy are unknown. The aim of this study was to assess the estimated glomerular filtration rates (eGFRs) and changes in serum BDNF levels in type 2 diabetic subjects treated with antihypertensive medications. In this randomized, double-blind clinical trial, type 2 diabetic subjects with hypertension were assigned to either the benazepril/amlodipine or valsartan/hydrochlorothiazide treatment groups for a 16-week period. The post hoc analyses were based on increased or decreased serum BDNF levels. Of the 153 enrolled subjects, the changes in eGFR were significantly and inversely correlated with those in BDNF in the 76 subjects treated with valsartan/hydrochlorothiazide (r = -0.264, P = 0.021) but not in the 77 subjects treated with benazepril/amlodipine (r = -0.025, P = 0.862). The 45 subjects with increased BDNF following valsartan/hydrochlorothiazide treatment exhibited a significantly reduced eGFR (-8.8 ± 14.9 mL/min/1.73 m(2); P benazepril.

  20. Development of nondestructive measurement of cold work rate, (2)

    International Nuclear Information System (INIS)

    Kamimura, Hideaki; Igarashi, Miyuki; Satoh, Masakazu; Miura, Makoto

    1978-01-01

    Cold-worked type 316 stainless steel will be used as fuel cladding material for the proto-type fast reactor MONJU. Cold work rate is an important parameter in swelling behavior of fuel cladding. It has been shown that austenitic stainless steel undergoes martensitic transformation during cold working. Nondestructive evaluation of cold work rate will be expected by measuring residual magnetism produced in the presence of martensitic phase when cold worked austenitic stainless steel is magnetized. In the previous work, the residual magnetism of cladding tubes of type 316 stainless steel was measured. The results have shown high degree of the correlation between residual magnetism and cold work rate. This paper reports the results of measurement on cold-rolled type 316 stainless steel plate samples. Dimensions of the specimens are 100 mm long and 3.5 and 7 mm wide. The apparatus and experimental procedures were similar to the previous work. Good agreement was found between the estimated cold work rate obtained in the previous work and that for cold rolled plate specimens. Measurement of residual magnetism in identical direction with magnetization showed smaller dispersion of data as compared with that in transverse direction. The residual magnetism near specimen surface hardly decreased when the surface of specimen was chemically removed. The reason for the comparative decrease in residual magnetism at 10% and 15% cold work rate is not clear. (Wakatsuki, Y.)

  1. Estimating average glandular dose by measuring glandular rate in mammograms

    International Nuclear Information System (INIS)

    Goto, Sachiko; Azuma, Yoshiharu; Sumimoto, Tetsuhiro; Eiho, Shigeru

    2003-01-01

    The glandular rate of the breast was objectively measured in order to calculate individual patient exposure dose (average glandular dose) in mammography. By employing image processing techniques and breast-equivalent phantoms with various glandular rate values, a conversion curve for pixel value to glandular rate can be determined by a neural network. Accordingly, the pixel values in clinical mammograms can be converted to the glandular rate value for each pixel. The individual average glandular dose can therefore be calculated using the individual glandular rates on the basis of the dosimetry method employed for quality control in mammography. In the present study, a data set of 100 craniocaudal mammograms from 50 patients was used to evaluate our method. The average glandular rate and average glandular dose of the data set were 41.2% and 1.79 mGy, respectively. The error in calculating the individual glandular rate can be estimated to be less than ±3%. When the calculation error of the glandular rate is taken into consideration, the error in the individual average glandular dose can be estimated to be 13% or less. We feel that our method for determining the glandular rate from mammograms is useful for minimizing subjectivity in the evaluation of patient breast composition. (author)

  2. Rapid Measurement of Neutron Dose Rate for Transport Index

    International Nuclear Information System (INIS)

    Morris, R.L.

    2000-01-01

    A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 μSv per hour (20 μrem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNPtrademark are reported for materials typical of those being shipped

  3. Three-dimensional spatial imaging in multiphoton ionization rate measurements

    International Nuclear Information System (INIS)

    Bredy, Richard; Camp, Howard A.; Nguyen, Hai; Awata, Takaaki; Shan Bing; Chang Zhenghu; DePaola, B.D.

    2004-01-01

    An experiment is described in which an apparatus is used to demonstrate the feasibility of measuring multiphoton photoionization rates in the interaction of short pulsed lasers with atoms or molecules. With this methodology, the ionization rate is measured as a function of the spatial position in the beam-waist region of the laser through the direct three-dimensional spatial imaging of the ionization events. Thus, if the spatial dependence of the laser beam intensity were known, a series of experiments could yield the intensity dependence of multiphoton ionization without the assumptions or errors that are generally inherent in the integration over one or more dimensions in the laser focal volume

  4. Measurement of thoron exhalation rates from building materials.

    Science.gov (United States)

    de With, G; de Jong, P; Röttger, A

    2014-09-01

    Thoron (220Rn) exhalation from building materials has become increasingly recognized as a potential source for radiation exposure in dwellings. However, contrary to radon (220Rn), limited information on thoron exposure is available. The purpose of this study is to develop a test method for the determination of the thoron exhalation rate from building materials. The method is validated, and subsequently the thoron exhalation rates from 10 widely-applied concretes, gypsums, brick, limestone, and mortar are determined. The measured thoron exhalation rates of these materials range from 0.01 Bq m-2 s-1 to 0.43 Bq m-2 s-1, with relative standard uncertainties between 6% to 14%.

  5. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  6. Correlation measurements of sodium flow rate with magnetic sensors

    International Nuclear Information System (INIS)

    Kebadze, B.V.; Krasnoyarov, N.V.; Adamovskij, L.A.; Golushko, V.V.; Sroelov, V.S.

    1978-01-01

    The results of bench-mark experiments and those carried out at the BOR-60 reactor to measure the sodium coolant flow rate by a correlation method are presented. The method is based on detecting the eddy type flow hydraulic nonuniformities using magnetic flowmeters. The measurements were fulfilled in a broad range of flow rates (G=10-10 4 m 3 /h, Re=2x10 5 -2x10 7 ). The measured and calculated mutual correlation functions are presented with parallel and perpendicular orientations of the flowmeters magnetic fields. A good accord is stated. Prerequirements to the arrangement of the measuring systems are formulated. As an important advantage of the correlation method a possibility of the flowmeter calibration in situ is hydhlighted

  7. Measurement of droplet vaporization rate enhancement caused by acoustic disturbances

    Science.gov (United States)

    Anderson, T. J.; Winter, M.

    1992-10-01

    Advanced laser diagnostics are being applied to quantify droplet vaporization enhancement in the presence of acoustic fields which can lead to instability in liquid-fueled rockets. While models have been developed to describe the interactions between subcritical droplet vaporization and acoustic fields in the surrounding gases, they have not been verified experimentally. In the super critical environment of a rocket engine combustor, little is understood about how the injected fluid is distributed. Experiments in these areas have been limited because of the lack of diagnostic techniques capable of providing quantitative results. Recently, however, extremely accurate vaporization rate measurements have been performed on droplets in a subcritical environment using morphology-dependent resonances (MDR's) in which fluorescence from an individual droplet provides information about its diameter. Initial measurements on methanol droplets behind a pressure pulse with a pressure ratio of 1.2 indicated that the evaporation rate in the first few microsec after wave passage was extremely high. Subsequent measurements have been made to validate these results using MDR's acquired from similarly-sized droplets using a pulse with a 1.1 pressure ratio. A baseline measurement was also made using a non evaporative fluid under similar Weber and Reynolds number conditions. The MDR technique employed for these measurements is explained and the facilities are described. The evaporation measurement results are shown and the rates observed from different droplet materials and different wave strengths are compared.

  8. Measurement of rates of cholesterol synthesis using tritiated water

    International Nuclear Information System (INIS)

    Dietschy, J.M.; Spady, D.K.

    1984-01-01

    Rates of sterol synthesis in various tissues commonly are assessed by assaying levels of 3-hydroxy-3-methylglutaryl CoA (HMG-CoA) reductase on isolated microsomes or by measuring the rates of incorporation of various 14 C-labeled substrates or [ 3 H]water into cholesterol by whole cell preparations in vitro or by the tissues of the whole animal in vivo. While measurement of activities of HMG-CoA reductase or rates of incorporation of 14 C-labeled substrates into cholesterol give useful relative rates of sterol production, neither method yields absolute rates of cholesterol synthesis. The use of [ 3 H]water circumvents the problem of variable and unknown dilution of the specific activity of the precursor pool encountered when 14 C-labeled substrates are used and does yield absolute rates of cholesterol synthesis provided that the 3 H/C incorporation ratio is known for a particular tissue. In 12 different experimental situations it has been found that from 21 to 27 micrograms atoms of 3 H are incorporated into cholesterol from [ 3 H]water in different tissues of several animal species, so that the 3 H/C incorporation ratio is similar under nearly all experimental conditions and varies from 0.78 to 1.00. When administered in vivo, [ 3 H]water rapidly equilibrates with intracellular water and is incorporated into sterols within the various organs at rates that are linear with respect to time. From such data it is possible to obtain absolute rates of cholesterol synthesis in the whole animal and in the various organs of the animal. Current data suggest, therefore, that use of [ 3 H]water yields the most accurate rates of cholesterol synthesis both in vitro and in vivo

  9. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  10. Sodium flow rate measurement method of annular linear induction pumps

    International Nuclear Information System (INIS)

    Araseki, Hideo; Kirillov, Igor R.; Preslitsky, Gennady V.

    2012-01-01

    Highlights: ► We found a new method of flow rate monitoring of electromagnetic pump. ► The method is very simple and does not require a large space. ► The method was verified with an experiment and a numerical analysis. ► The experimental data and the numerical results are in good agreement. - Abstract: The present paper proposes a method for measuring sodium flow rate of annular linear induction pumps. The feature of the method lies in measuring the leaked magnetic field with measuring coils near the stator end on the outlet side and in correlating it with the sodium flow rate. This method is verified through an experiment and a numerical analysis. The data obtained in the experiment reveals that the correlation between the leaked magnetic field and the sodium flow rate is almost linear. The result of the numerical analysis agrees with the experimental data. The present method will be particularly effective to sodium flow rate monitoring of each one of plural annular linear induction pumps arranged in parallel in a vessel which forms a large-scale pump unit.

  11. Inter-Observer Agreement in Measuring Respiratory Rate

    DEFF Research Database (Denmark)

    Nielsen, Louise Gramstrup; Folkestad, Lars; Brodersen, Jacob Broder

    2015-01-01

    BACKGROUND: Respiratory rate (RR) is an important vital sign which is strongly correlated with in-hospital mortality. At the same time, RR is the most likely vital sign to be omitted when assessing a patient. We believe that one reason for this could be the difficulty in measure the RR, since...

  12. High-temperature rate constant measurements for OH+xylenes

    KAUST Repository

    Elwardani, Ahmed Elsaid; Badra, Jihad; Farooq, Aamir

    2015-01-01

    The overall rate constants for the reactions of hydroxyl (OH) radicals with o-xylene (k 1), m-xylene (k 2), and p-xylene (k 3) were measured behind reflected shock waves over 890-1406K at pressures of 1.3-1.8atm using OH laser absorption near 306

  13. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  14. Diesel fuel filtration system

    International Nuclear Information System (INIS)

    Schneider, D.

    1996-01-01

    The American nuclear utility industry is subject to tight regulations on the quality of diesel fuel that is stored at nuclear generating stations. This fuel is required to supply safety-related emergency diesel generators--the backup power systems associated with the safe shutdown of reactors. One important parameter being regulated is the level of particulate contamination in the diesel fuel. Carbon particulate is a natural byproduct of aging diesel fuel. Carbon particulate precipitates from the fuel's hydrocarbons, then remains suspended or settles to the bottom of fuel oil storage tanks. If the carbon particulate is not removed, unacceptable levels of particulate contamination will eventually occur. The oil must be discarded or filtered. Having an outside contractor come to the plant to filter the diesel fuel can be costly and time consuming. Time is an even more critical factor if a nuclear plant is in a Limiting Condition of Operation (LCO) situation. A most effective way to reduce both cost and risk is for a utility to build and install its own diesel fuel filtration system. The cost savings associated with designing, fabricating and operating the system inhouse can be significant, and the value of reducing the risk of reactor shutdown because of uncertified diesel fuel may be even higher. This article describes such a fuel filtering system

  15. MEASURING TINY MASS ACCRETION RATES ONTO YOUNG BROWN DWARFS

    International Nuclear Information System (INIS)

    Herczeg, Gregory J.; Cruz, Kelle L.; Hillenbrand, Lynne A.

    2009-01-01

    We present low-resolution Keck I/LRIS spectra spanning from 3200 to 9000 A of nine young brown dwarfs and three low-mass stars in the TW Hya Association and in Upper Sco. The optical spectral types of the brown dwarfs range from M5.5 to M8.75, though two have near-IR spectral types of early L dwarfs. We report new accretion rates derived from excess Balmer continuum emission for the low-mass stars TW Hya and Hen 3-600A and the brown dwarfs 2MASS J12073347-3932540, UScoCTIO 128, SSSPM J1102-3431, USco J160606.29-233513.3, DENIS-P J160603.9-205644, and Oph J162225-240515B, and upper limits on accretion for the low-mass star Hen 3-600B and the brown dwarfs UScoCTIO 112, Oph J162225-240515A, and USco J160723.82-221102.0. For the six brown dwarfs in our sample that are faintest at short wavelengths, the accretion luminosity or upper limit is measurable only when the image is binned over large wavelength intervals. This method extends our sensitivity to accretion rate down to ∼10 -13 M sun yr -1 for brown dwarfs. Since the ability to measure an accretion rate from excess Balmer continuum emission depends on the contrast between excess continuum emission and the underlying photosphere, for objects with earlier spectral types the upper limit on accretion rate is much higher. Absolute uncertainties in our accretion rate measurements of ∼3-5 include uncertainty in accretion models, brown dwarf masses, and distance. The accretion rate of 2 x 10 -12 M sun yr -1 onto 2MASS J12073347-3932540 is within 15% of two previous measurements, despite large changes in the Hα flux.

  16. Waste tank ventilation rates measured with a tracer gas method

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Evans, J.C.; Sklarew, D.S.; Mitroshkov, A.V.

    1998-08-01

    Passive ventilation with the atmosphere is used to prevent accumulation of waste gases and vapors in the headspaces of 132 of the 177 high-level radioactive waste Tanks at the Hanford Site in Southeastern Washington State. Measurements of the passive ventilation rates are needed for the resolution of two key safety issues associated with the rates of flammable gas production and accumulation and the rates at which organic salt-nitrate salt mixtures dry out. Direct measurement of passive ventilation rates using mass flow meters is not feasible because ventilation occurs va multiple pathways to the atmosphere (i.e., via the filtered breather riser and unsealed tank risers and pits), as well as via underground connections to other tanks, junction boxes, and inactive ventilation systems. The tracer gas method discussed in this report provides a direct measurement of the rate at which gases are removed by ventilation and an indirect measurement of the ventilation rate. The tracer gas behaves as a surrogate of the waste-generated gases, but it is only diminished via ventilation, whereas the waste gases are continuously released by the waste and may be subject to depletion mechanisms other than ventilation. The fiscal year 1998 tracer studies provide new evidence that significant exchange of air occurs between tanks via the underground cascade pipes. Most of the single-shell waste tanks are connected via 7.6-cm diameter cascade pipes to one or two adjacent tanks. Tracer gas studies of the Tank U-102/U-103 system indicated that the ventilation occurring via the cascade line could be a significant fraction of the total ventilation. In this two-tank cascade, air evidently flowed from Tank U-103 to Tank U-102 for a time and then was observed to flow from Tank U-102 to Tank U-103

  17. Measurement for the Leak Rate enhanced by a Improved Method

    International Nuclear Information System (INIS)

    Bae, Sang-Hoon; Choi, Young-San; Kim, Young-Ki; Lee, Yong-Sub; Jung, Hoan-Sung

    2007-01-01

    The leak rate measurement of the HANARO such as a research reactor that adopts a confinement concept for a reactor hall is very important one during a period inspection. This test verifies whether the reactor building could maintain the negative pressure or not when radiation is perceived by abnormal accidents. Of course, this may not cause a problem in a reactor operation only if it can satisfy the design requirement, but it is necessary to have some margin of a limitation value because a reactor hall should be managed more conservatively than the design reference. To meet the requirements of this strict design condition, previous method was changed to a new type of test with more stable and robust measuring method. The new leak rate measurement method is briefly introduced and the merits of this proposed method are shown through the data analyzed for last 3 years

  18. High-temperature rate constant measurements for OH+xylenes

    KAUST Repository

    Elwardani, Ahmed Elsaid

    2015-06-01

    The overall rate constants for the reactions of hydroxyl (OH) radicals with o-xylene (k 1), m-xylene (k 2), and p-xylene (k 3) were measured behind reflected shock waves over 890-1406K at pressures of 1.3-1.8atm using OH laser absorption near 306.7nm. Measurements were performed under pseudo-first-order conditions. The measured rate constants, inferred using a mechanism-fitting approach, can be expressed in Arrhenius form as:k1=2.93×1013exp(-1350.3/T)cm3mol-1s-1(890-1406K)k2=3.49×1013exp(-1449.3/T)cm3mol-1s-1(906-1391K)k3=3.5×1013exp(-1407.5/T)cm3mol-1s-1(908-1383K)This paper presents, to our knowledge, first high-temperature measurements of the rate constants of the reactions of xylene isomers with OH radicals. Low-temperature rate-constant measurements by Nicovich et al. (1981) were combined with the measurements in this study to obtain the following Arrhenius expressions, which are applicable over a wider temperature range:k1=2.64×1013exp(-1181.5/T)cm3mol-1s-1(508-1406K)k2=3.05×109exp(-400/T)cm3mol-1s-1(508-1391K)k3=3.0×109exp(-440/T)cm3mol-1s-1(526-1383K) © 2015 The Combustion Institute.

  19. Problems of multiphase fluid filtration

    CERN Document Server

    Konovalov, AN

    1994-01-01

    This book deals with a spectrum of problems related to the mathematical modeling of multiphase filtration. Emphasis is placed on an inseparable triad: model - algorithm - computer code. An analysis of new and traditional filtration problems from the point of view of both their numerical implementation and the reproduction of one or another technological characteristics of the processes under consideration is given. The basic principles which underlie the construction of efficient numerical methods taking into account the filtration problems are discussed: non-evolutionary nature, degeneration,

  20. Precedents For Authorization Of Contents Using Dose Rate Measurements

    International Nuclear Information System (INIS)

    Abramczyk, G.; Bellamy, S.; Nathan, S.; Loftin, B.

    2012-01-01

    For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

  1. MEASURING THE EVOLUTIONARY RATE OF COOLING OF ZZ Ceti

    Energy Technology Data Exchange (ETDEWEB)

    Mukadam, Anjum S.; Fraser, Oliver; Riecken, T. S.; Kronberg, M. E. [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); Bischoff-Kim, Agnes [Georgia College and State University, Milledgeville, GA 31061 (United States); Corsico, A. H. [Facultad de Ciencias Astronomicas y Geofisicas, Universidad Nacional de La Plata (Argentina); Montgomery, M. H.; Winget, D. E.; Hermes, J. J.; Winget, K. I.; Falcon, Ross E.; Reaves, D. [Department of Astronomy, University of Texas at Austin, Austin, TX 78759 (United States); Kepler, S. O.; Romero, A. D. [Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, RS (Brazil); Chandler, D. W. [Meyer Observatory, Central Texas Astronomical Society, 3409 Whispering Oaks, Temple, TX 76504 (United States); Kuehne, J. W. [McDonald Observatory, Fort Davis, TX 79734 (United States); Sullivan, D. J. [Victoria University of Wellington, P.O. Box 600, Wellington (New Zealand); Von Hippel, T. [Embry-Riddle Aeronautical University, 600 South Clyde Morris Boulevard, Daytona Beach, FL 32114 (United States); Mullally, F. [SETI Institute, NASA Ames Research Center, MS 244-30, Moffet Field, CA 94035 (United States); Shipman, H. [Delaware Asteroseismic Research Center, Mt. Cuba Observatory, Greenville, DE 19807 (United States); and others

    2013-07-01

    We have finally measured the evolutionary rate of cooling of the pulsating hydrogen atmosphere (DA) white dwarf ZZ Ceti (Ross 548), as reflected by the drift rate of the 213.13260694 s period. Using 41 yr of time-series photometry from 1970 November to 2012 January, we determine the rate of change of this period with time to be dP/dt = (5.2 {+-} 1.4) Multiplication-Sign 10{sup -15} s s{sup -1} employing the O - C method and (5.45 {+-} 0.79) Multiplication-Sign 10{sup -15} s s{sup -1} using a direct nonlinear least squares fit to the entire lightcurve. We adopt the dP/dt obtained from the nonlinear least squares program as our final determination, but augment the corresponding uncertainty to a more realistic value, ultimately arriving at the measurement of dP/dt = (5.5 {+-} 1.0) Multiplication-Sign 10{sup -15} s s{sup -1}. After correcting for proper motion, the evolutionary rate of cooling of ZZ Ceti is computed to be (3.3 {+-} 1.1) Multiplication-Sign 10{sup -15} s s{sup -1}. This value is consistent within uncertainties with the measurement of (4.19 {+-} 0.73) Multiplication-Sign 10{sup -15} s s{sup -1} for another similar pulsating DA white dwarf, G 117-B15A. Measuring the cooling rate of ZZ Ceti helps us refine our stellar structure and evolutionary models, as cooling depends mainly on the core composition and stellar mass. Calibrating white dwarf cooling curves with this measurement will reduce the theoretical uncertainties involved in white dwarf cosmochronometry. Should the 213.13 s period be trapped in the hydrogen envelope, then our determination of its drift rate compared to the expected evolutionary rate suggests an additional source of stellar cooling. Attributing the excess cooling to the emission of axions imposes a constraint on the mass of the hypothetical axion particle.

  2. Evaporation rate measurement in the pool of IEAR-1 reactor

    International Nuclear Information System (INIS)

    Torres, Walmir Maximo; Cegalla, Miriam A.; Baptista Filho, Benedito Dias

    2000-01-01

    The surface water evaporation in pool type reactors affects the ventilation system operation and the ambient conditions and dose rates in the operation room. This paper shows the results of evaporation rate experiment in the pool of IEA-R1 research reactor. The experiment is based on the demineralized water mass variation inside cylindrical metallic recipients during a time interval. Other parameters were measured, such as: barometric pressure, relative humidity, environmental temperature, water temperature inside the recipients and water temperature in the reactor pool. The pool level variation due to water contraction/expansion was calculated. (author)

  3. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  4. Latest aspects of mechanical filtration

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available The aim of this study was to describe and unify all knowledge about mechanic filtration. The first part deals with the parameters and properties of filtration. Here some important basic concepts are explained such as pressure gradient, filter life, etc. There’s also a description of convenient filtration technology for coarse and fine materials, such as sand, smoke or soot. The second part primarily focuses on the real use and application of filters for liquid and gaseous media. The differences in construction between different types of filters for filtration of fuels, oils, hydraulic fluids, air and cabin filters are described. The last section is focused mainly on new materials for the production of filters. These materials are ceramic or nanomaterials, which can actually be enriched for example with antibacterial silver or some fungicides.

  5. Dosimetric measurement of the disintegration rate of fission products

    International Nuclear Information System (INIS)

    Solymosi, J.; Nagy, L.G.; Zagyvai, P.

    1992-01-01

    Investigations on the disintegration rate of fission products of 238 U and 239 Pu are presented. The intensity of the β-and γ-radiation of fission products were measured continously in an interval of 1-1300 hours following the fission, offering the possibility for determining the general and specific characteristics of the individual fission products. A universal measuring procedure was elaborated for the rapid in situ determination of the dosimetric features of fission products, which is suitable for the accurate evaluation and prediction of external absorbed dose even in case of fission products of various origin and unknown composition. (author) 6 refs.; 7 figs.; 1 tab

  6. Miniature electron bombardment evaporation source: evaporation rate measurement

    International Nuclear Information System (INIS)

    Nehasil, V.; Masek, K.; Matolin, V.; Moreau, O.

    1997-01-01

    Miniature electron beam evaporation sources which operate on the principle of vaporization of source material, in the form of a tip, by electron bombardment are produced by several companies specialized in UHV equipment. These sources are used primarily for materials that are normally difficult to deposit due to their high evaporation temperature. They are appropriate for special applications such as heteroepitaxial thin film growth requiring a very low and well controlled deposition rate. A simple and easily applicable method of evaporation rate control is proposed. The method is based on the measurement of ion current produced by electron bombardment of evaporated atoms. The absolute evaporation flux values were measured by means of the Bayard-Alpert ion gauge, which enabled the ion current vs evaporation flux calibration curves to be plotted. (author). 1 tab., 4 figs., 6 refs

  7. In situ measurements of thoron exhalation rate in Okinawa (Japan)

    International Nuclear Information System (INIS)

    Shiroma, Y.; Isa, N.; Hosoda, M.; Sorimachi, A.; Ishikawa, T.; Tokonami, S.; Furukawa, M.

    2010-01-01

    Thoron exhalation rates from the ground surface were measured at 57 sites on Okinawa Island (Japan), using a ZnS(Ag) scintillation detector equipped with photomultiplier. The arithmetic means ± SD, median ± SD, minimum and maximum of the rates (unit: Bq m -2 s -1 ) were estimated to be 1.9 ± 1.4, 1.6 ± 0.3, 0.04 and 6.2, respectively. The soils distributed on the island are generally classified into dark red soils, residual regosols, as well as red and yellow soils. While it was assumed that the soils were originated from the bedrock, recent studies suggested that the main material of dark red soils is the East Asian eolian dust. In the dark red soils area, the exhalation rate is relatively higher than that in the other areas. This suggested that the eolian dust was an enhancer for the environmental thoron concentration on Okinawa Island. (authors)

  8. Aerosol filtration with metallic fibrous filters

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.

    1983-01-01

    The filtration efficiency of stainless steel fibrous filters (BEKIPOR porous mats and sintered webs) is determined using submicronic monodisperse polystyrene aerosols. Lasers spectrometers are used for the aerosol measurements. The parameters varied are the fiber diameter, the number of layers, the aerosol diameter and the superficial velocity. Two selected types of filters are tested with polydisperse methylene blue aerosols to determine the effect of bed loading on the filter performance and to test washing techniques for the regeneration of the filter

  9. Comparison between Medgem and Deltatrac resting metabolic rate measurements.

    Science.gov (United States)

    Compher, C; Hise, M; Sternberg, A; Kinosian, B P

    2005-10-01

    The primary aims of this trial were to evaluate the reproducibility of a portable handheld calorimeter (Medgem) in a clinical population, and to compare its measures with a calorimeter in typical use with these patients. Cross-sectional clinical validation study. Outpatient Clinical Research Center. A total of 24 stable home nutrition support patients. In random order three measures of resting metabolic rate (RMR) were taken after a 4-h fast, 15 min rest and 2-h abstention from exercise. Two measures were taken with the same Medgem (MG) and one with the traditional calorimeter (Deltatrac). Reproducibility of MG measures and their comparability to a Deltatrac measure were assessed by Bland-Altman analysis, with >+/-250 kcal/day established a priori as a clinically unacceptable error. In addition, disagreement between the two types of measures was defined as greater than 10% difference. The mean difference between two MG measures was -6.8 kcal/day, with limits of agreement between 233 and -247 kcal/day and clinically acceptable. The mean difference between the Deltatrac and mean of two MG measures was -162 kcal/day, with limits of agreement between 577 and -253 kcal/day and clinically unacceptable. In all, 80% of the repeated MG RMR measures agreed within 10%, and the mean MG reading agreed with the Deltatrac in 60% of cases. RMR obtained using the MG calorimeter has an acceptable degree of reproducibility, and is acceptable to patients. The MG measures, however, are frequently lower than traditional measures and require further validation prior to application to practice in this vulnerable patient group.

  10. Acute change in glomerular filtration rate with inhibition of the renin-angiotensin system does not predict subsequent renal and cardiovascular outcomes.

    Science.gov (United States)

    Clase, Catherine M; Barzilay, Joshua; Gao, Peggy; Smyth, Andrew; Schmieder, Roland E; Tobe, Sheldon; Teo, Koon K; Yusuf, Salim; Mann, Johannes F E

    2017-03-01

    Initiation of blockade of the renin-angiotensin system may cause an acute decrease in glomerular filtration rate (GFR): the prognostic significance of this is unknown. We did a post hoc analysis of patients with, or at risk for, vascular disease, in two randomized controlled trials: Ongoing Telmisartan Alone and in combination with Ramipril Global Endpoint Trial (ONTARGET) and the Telmisartan Randomized AssessmeNt Study in ACE iNtolerant participants with cardiovascular Disease (TRANSCEND), whose median follow-up was 56 months. In 9340 patients new to renin-angiotensin system blockade, who were then randomized to renin-angiotensin system blockade, a fall in GFR of 15% or more at 2 weeks after starting renin-angiotensin system blockade was seen in 1480 participants (16%), with persistence at 8 weeks in 700 (7%). Both acute increases and decreases in GFR after initiation of renin-angiotensin system blockade were associated with tendencies, mostly not statistically significant, to increased risk of cardiovascular outcomes, which occurred in 1280 participants, and of microalbuminuria, which occurred in 864. Analyses of creatinine-based outcomes were suggestive of regression to the mean. In more than 3000 patients randomized in TRANSCEND to telmisartan or placebo, there was no interaction between acute change in GFR and renal or cardiovascular benefit from telmisartan. Thus, both increases and decreases in GFR on initiation of renin-angiotensin system blockade are common, and may be weakly associated with increased risk of cardiovascular and renal outcomes. Changes do not predict increased benefit from therapy. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  11. Tc-99m Hydroxymethylene Diphosphonate (HMDP) Renal Uptake as a Surrogate Marker of Postoperative Impairment of the Glomerular Filtration Rate in Renal Tumor Patients Following Nephron-Sparing Surgery.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Won Woo; So, Young; Ha, Seunggyun; Byun, Seok-Soo; Kim, Sang Eun

    2014-12-01

    We investigated Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy findings in renal tumor patients from the perspective of postoperative renal dysfunction following nephron-sparing surgery (NSS). Forty-three renal tumor patients (M:F = 28:15, age 53.9 ± 12.5 years) who had undergone Tc-99m HMDP scintigraphy after NSS were enrolled. The patients were divided into HMDP(+) or HMDP(-) groups by visual assessment, and the asymmetric index (ASI) was calculated using a region-of-interest analysis. In 16 patients, the total and split glomerular filtration rate (GFR) was assessed using Tc-99m diethylenetriaminepentaacetic acid (DTPA) scintigraphy at baseline and at 3 and 6 months post-NSS. High Tc-99m HMDP uptake was observed in the operated kidneys, but this did not persist later than 7 days post-NSS. Split GFR of the operated kidneys at baseline (58.5 ± 9.3 ml/min) was significantly reduced at 6 months post-NSS (40.1 ± 5.9 ml/min, p Tc-99m HMDP. Declines in both total GFR (p = 0.010 and p = 0.002 for 3 and 6 months, respectively) and split GFR of the operated kidneys (p Tc-99m HMDP in the operated kidneys. The ASI was negatively correlated with %change in the split GFR of these operated kidneys at 6 months post-NSS (rho =-0.578, p = 0.0304). Tc-99m HMDP uptake within 1 week following NSS is a surrogate marker of GFR impairment over 6 months post-NSS.

  12. Fluctuations of Estimated Glomerular Filtration Rate Outside Kidney Disease Improving Global Outcomes Diagnostic Criteria for Acute Kidney Injury in End-Stage Liver Disease Outpatients and Outcome Postliver Transplantation

    Directory of Open Access Journals (Sweden)

    Federica Fiacco, MD

    2018-01-01

    Full Text Available Background. Renal dysfunction in end-stage liver disease (ESLD results from systemic conditions that affect both liver and kidney with activation of vasoconstrictor systems. In this setting, estimated glomerular filtration rate (eGFR may undergo variations often outside Kidney Disease Improving Global Outcomes criteria for acute kidney injury (AKI diagnosis, whose meaning is not clear. The aim of this study was to evaluate eGFR variations in ESLD outpatients listed for liver transplant (liver Tx and the association with post-Tx outcome. Methods. Fifty-one patients with ESLD were retrospectively evaluated from listing to transplant (L-Tx time, intraoperatively (Tx time, and up to 5 years post-Tx time. Variations between the highest and the lowest eGFR occurring in more than 48 hours, not satisfying Kidney Disease Improving Global Outcomes guideline, were considered as fluctuations (eGFR-F. Fluctuations of eGFR greater than 50% were defined as eGFR drops (DeGFR. Early graft dysfunction, AKI within 7 days, chronic kidney disease, and short- and long-term patient survivals were considered as outcomes. Results. All patients presented eGFR-F, whereas DeGFR were observed in 18 (35.3% of 51 (DeGFR+ group. These patients presented higher levels of Model for End-stage Liver Disease score, pre-Tx bilirubin and significantly greater incidence of post-Tx AKI stages 2 to 3 compared with patients without drops (DeGFR−. DeGFR was the only independent predictive factor of the occurrence of post-Tx AKI. The occurrence of AKI post-Tx was associated with the development of chronic kidney disease at 3 months and 5 years post-Tx. Conclusions. Drops of eGFR are more frequently observed in patients with a worse degree of ESLD and are associated with a worse post-Tx kidney outcome.

  13. Estimated Visceral Adipose Tissue, but Not Body Mass Index, Is Associated with Reductions in Glomerular Filtration Rate Based on Cystatin C in the Early Stages of Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ana Karina Teixeira da Cunha França

    2014-01-01

    Full Text Available Information on the association between obesity and initial phases of chronic kidney disease (CKD is still limited, principally those regarding the influence of visceral adipose tissue. We investigated whether the visceral adipose tissue is more associated with reductions in glomerular filtration rate (GFR than total and abdominal obesity in hypertensive individuals with stage 1-2 CKD. A cross-sectional study was implemented which involved 241 hypertensive patients undergoing treatment at a primary health care facility. GFR was estimated using equations based on creatinine and cystatin C levels. Explanatory variables included body mass index (BMI, waist circumference (WC, and estimated visceral adipose tissue (eVAT. The mean age was 59.6±9.2 years old and 75.9% were female. According to BMI, 28.2% of subjects were obese. Prevalence of increased WC and eVAT was 63.9% and 58.5%, respectively. Results from the assessment of GFR by BMI, WC, and eVAT categories showed that only women with increased eVAT (≥150 cm2 had a lower mean GFR by Larsson (P=0.016, Levey 2 (P=0.005, and Levey 3 (P=0.008 equations. The same result was not observed when the MDRD equation was employed. No association was found between BMI, WC, eVAT, and GFR using only serum creatinine. In the early stages of CKD, increased eVAT in hypertensive women was associated with decreased GFR based on cystatin C.

  14. Assessment of Glomerular Filtration Rate Based on Alterations of Serum Brain-Derived Neurotrophic Factor in Type 2 Diabetic Subjects Treated with Amlodipine/Benazepril or Valsartan/Hydrochlorothiazide

    Directory of Open Access Journals (Sweden)

    I-Te Lee

    2015-01-01

    Full Text Available Background. Brain-derived neurotrophic factor (BDNF is associated with sympathetic activation. However, the effects of BDNF on diabetic nephropathy are unknown. The aim of this study was to assess the estimated glomerular filtration rates (eGFRs and changes in serum BDNF levels in type 2 diabetic subjects treated with antihypertensive medications. Methods. In this randomized, double-blind clinical trial, type 2 diabetic subjects with hypertension were assigned to either the benazepril/amlodipine or valsartan/hydrochlorothiazide treatment groups for a 16-week period. The post hoc analyses were based on increased or decreased serum BDNF levels. Results. Of the 153 enrolled subjects, the changes in eGFR were significantly and inversely correlated with those in BDNF in the 76 subjects treated with valsartan/hydrochlorothiazide (r=-0.264, P=0.021 but not in the 77 subjects treated with benazepril/amlodipine (r=-0.025, P=0.862. The 45 subjects with increased BDNF following valsartan/hydrochlorothiazide treatment exhibited a significantly reduced eGFR (-8.8±14.9 mL/min/1.73 m2; P<0.001. Multivariate regression analysis revealed that increased serum BDNF represents an independent factor for reduced eGFR (95% confidence interval between −0.887 and −0.076, P=0.020. Conclusions. Increased serum BDNF is associated with reduced eGFR in type 2 diabetic subjects treated with valsartan/hydrochlorothiazide but not with amlodipine/benazepril.

  15. Estimating glomerular filtration rate (GFR) in children. The average between a cystatin C- and a creatinine-based equation improves estimation of GFR in both children and adults and enables diagnosing Shrunken Pore Syndrome.

    Science.gov (United States)

    Leion, Felicia; Hegbrant, Josefine; den Bakker, Emil; Jonsson, Magnus; Abrahamson, Magnus; Nyman, Ulf; Björk, Jonas; Lindström, Veronica; Larsson, Anders; Bökenkamp, Arend; Grubb, Anders

    2017-09-01

    Estimating glomerular filtration rate (GFR) in adults by using the average of values obtained by a cystatin C- (eGFR cystatin C ) and a creatinine-based (eGFR creatinine ) equation shows at least the same diagnostic performance as GFR estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparison of eGFR cystatin C and eGFR creatinine plays a pivotal role in the diagnosis of Shrunken Pore Syndrome, where low eGFR cystatin C compared to eGFR creatinine has been associated with higher mortality in adults. The present study was undertaken to elucidate if this concept can also be applied in children. Using iohexol and inulin clearance as gold standard in 702 children, we studied the diagnostic performance of 10 creatinine-based, 5 cystatin C-based and 3 combined cystatin C-creatinine eGFR equations and compared them to the result of the average of 9 pairs of a eGFR cystatin C and a eGFR creatinine estimate. While creatinine-based GFR estimations are unsuitable in children unless calibrated in a pediatric or mixed pediatric-adult population, cystatin C-based estimations in general performed well in children. The average of a suitable creatinine-based and a cystatin C-based equation generally displayed a better diagnostic performance than estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparing eGFR cystatin and eGFR creatinine may help identify pediatric patients with Shrunken Pore Syndrome.

  16. Measurement of soluble nuclide dissolution rates from spent fuel

    International Nuclear Information System (INIS)

    Wilson, C.N.; Gray, W.J.

    1990-01-01

    Gaining a better understanding of the potential release behavior of water-soluble radionuclides is the focus of new laboratory spent fuel dissolution studies being planned in support of the Yucca Mountain Project. Previous studies have suggested that maximum release rates for actinide nuclides, which account for most of the long-term radioactivity in spent fuel, should be solubility-limited and should not depend on the characteristics or durability of the spent fuel waste form. Maximum actinide concentrations should be sufficiently low to meet the NRC (Nuclear Regulatory Commission) annual release limits. Potential release rates for soluble nuclides such as 99 Tc, 135 Cs, 14 C and 129 I, which account for about 1-2% of the activity in spent fuel at 1,000 years, are less certain and may depend on processes such as oxidation of the fuel in the repository air environment. Dissolution rates for several soluble nuclides have been measured from spent fuel specimens using static and semi-static methods. However, such tests do not provide a direct measurement of fuel matrix dissolution rates that may ultimately control soluble-nuclide release rates. Flow-through tests are being developed as a potential supplemental method for determining the matrix component of soluble-nuclide dissolution. Advantages and disadvantages of both semi-static and flow-through methods are discussed. Tests with fuel specimens representing a range of potential fuel states that may occur in the repository, including oxidized fuel, are proposed. Preliminary results from flow-through tests with unirradiated UO 2 suggesting that matrix dissolution rates are very sensitive to water composition are also presented

  17. Hanford phosphate precipitation filtration process evaluation

    International Nuclear Information System (INIS)

    Walker, B.W.; McCabe, D.J.

    1997-01-01

    The purpose of this filter study was to evaluate cross-flow filtration as effective solid-liquid separation technology for treating Hanford wastes, outline operating conditions for equipment, examine the expected filter flow rates, and determine proper cleaning. A proposed Hanford waste pre-treatment process uses sodium hydroxide at high temperature to remove aluminum from sludge. This process also dissolves phosphates. Upon cooling to 40 degrees centigrade the phosphates form a Na7(PO4)2F9H2O precipitate which must be removed prior to further treatment. Filter studies were conducted with a phosphate slurry simulant to evaluate whether 0.5 micron cross-flow sintered metal Mott filters can separate the phosphate precipitate from the wash solutions. The simulant was recirculated through the filters at room temperature and filtration performance data was collected

  18. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  19. Health benefits of particle filtration.

    Science.gov (United States)

    Fisk, W J

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, for example, 7% to 25%. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air. Published 2013. This article is a US Government work and is in the public domain in the USA.

  20. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also, reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percent age improvement in health outcomes is typically modest, for example, 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  1. Health Benefits of Particle Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.

    2013-10-01

    The evidence of health benefits of particle filtration in homes and commercial buildings is reviewed. Prior reviews of papers published before 2000 are summarized. The results of 16 more recent intervention studies are compiled and analyzed. Also reviewed are four studies that modeled health benefits of using filtration to reduce indoor exposures to particles from outdoors. Prior reviews generally concluded that particle filtration is, at best, a source of small improvements in allergy and asthma health effects; however, many early studies had weak designs. A majority of recent intervention studies employed strong designs and more of these studies report statistically significant improvements in health symptoms or objective health outcomes, particularly for subjects with allergies or asthma. The percentage improvement in health outcomes is typically modest, e.g., 7percent to 25percent. Delivery of filtered air to the breathing zone of sleeping allergic or asthmatic persons may be more consistently effective in improving health than room air filtration. Notable are two studies that report statistically significant improvements, with filtration, in markers that predict future adverse coronary events. From modeling, the largest potential benefits of indoor particle filtration may be reductions in morbidity and mortality from reducing indoor exposures to particles from outdoor air.

  2. Measurement of sulfur dioxide oxidation rates in wintertime orographic clouds

    International Nuclear Information System (INIS)

    Snider, J.R.

    1990-01-01

    SO2-reaction studies in the clouds are examined and summarized to experimentally confirm model predictions and previous field studies regarding dominant SO2-reaction pathways. Controlled amounts of SO2 were released into nonprecipitating orographic clouds, and sulfate yields are compared to oxidant depletions. The sulfate yields were taken from cloud-water samples and liquid-water-concentration measurements, and oxidant-depletion data were generated from continuous gas-phase measurements. Comparisons of Y sub SO4 and D sub H2O2 suggest that H2O2 is the dominant oxidant, and the in-cloud reaction between H2O2 and the bisulfite ion can be expressed by a simple rate that agrees with predictions and laboratory results. The rate measurements are found to be inconsistent with the rate law proposed by Hegg and Hobbs (1982) and with some observational data. The present conclusions are of interest to evaluating the effects of sulfur dioxide emissions on sulfuric acid deposition. 30 refs

  3. Measurement of blowdown flow rates using load cells

    International Nuclear Information System (INIS)

    Dolas, P.K.; Venkat Raj, V.; Ghosh, A.K.; Murty, L.G.K.; Muralidhar Rao, S.

    1980-01-01

    To establish a reliable method for measuring two-phase flow, experiments were planned for measurement of transient single phase flow rates from vessels using load cells. Suitability of lead-zirconate-titanate piezoelectric ceramic discs was examined. Discharge time constant of the disc used was low, leading to large measurement errors. Subsequently, experiments were carried out using strain gauge load cells and these were found satisfactory. The unsteady flow equation has been derived for the system under investigation. The equation has been solved numerically using the fourth order Runge-Kutta method and also by integrating it analytically. The experimental results are compared with the theoretical results and presented in this report. (auth.)

  4. Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    Science.gov (United States)

    Tsouri, Gill R.; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K.

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  5. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A large number of portable survey instruments employing G.M., ionization chamber, and scintillation detectors used for gamma measurements are also used for monitoring in beta fields by using removable shields to separate the beta and gamma components of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. Appropriate calibrations and correction factors can be used to reduce the errors in beta measurements to a tolerable level

  6. Measurements of astrophysical reaction rates for radioactive samples

    International Nuclear Information System (INIS)

    Koehler, P.E.; O'Brien, H.A.; Bowman, C.D.

    1987-01-01

    Reaction rates for both big-bang and stellar nucleosynthesis can be obtained from the measurement of (n,p) and (n,γ) cross sections for radioactive nuclei. In the past, large backgrounds associated with the sample activity limited these types of measurements to radioisotopes with very long half lives. The advent of the low-energy, high-intensity neutron source at the Los Alamos Neutron Scattering CEnter (LANSCE) has greatly increased the number of nuclei which can be studied. Results of (n,p) measurements on samples with half lives as short as fifty-three days will be given. The astrophysics to be learned from these data will be discussed. Additional difficulties are encountered when making (n,γ) rather than (n,p) measurements. However, with a properly designed detector, and with the high peak neutron intensities now available, (n,γ) measurements can be made for nuclei with half lives as short as several weeks. Progress on the Los Alamos (n,γ) cross-section measurement program for radioactive samples will be discussed. 25 refs., 3 figs., 1 tab

  7. A new high rate positron lifetime measurement system

    International Nuclear Information System (INIS)

    Bedwell, M.O.; Paulus, T.J.

    1979-01-01

    Positron lifetime measuring system, a technique to perform non-destructive studies on the internal structure of materials, has many components common to those used for nuclear time spectroscopy systems. In each case, a timing coincidence curve is measured for the energy range of interest, and this is accomplished in a typical timing coincidence system. The paper first describes the conventional timing coincidence system, then a new fast timing system is introduced. Comparing to the conventional fast/slow timing system, the fast timing technique offers reduced complexity, lower system cost, and improved high data rate capability. Experimental results show that the FWHM timing resolution ranges from 190 ps for a 1.1 : 1 dynamic range to 337 ps for a 100 : 1 dynamic range of signals with 60 Co. As for the timing resolution as a function of energy, the FWHM resolution for each channel ranges from 124 ps at 1 MeV to 400 ps at 100 keV. Since the excellent timing performance is maintained even at very high input rate, the experimenters can use much more active sources to increase the true coincidence rate and reduce data accumulation time. This method has the added advantage of minimizing long term drift effects since the experiments can be conducted in less time. (Wakatsuki, Y.)

  8. Measurements of waste tank passive ventilation rates using tracer gases

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Olsen, K.B.; Sklarew, D.S.; Evans, J.C.; Remund, K.M.

    1997-09-01

    This report presents the results of ventilation rate studies of eight passively ventilated high-level radioactive waste tanks using tracer gases. Head space ventilation rates were determined for Tanks A-101, AX-102, AX-103, BY-105, C-107, S-102, U-103, and U-105 using sulfur hexafluoride (SF 6 ) and/or helium (He) as tracer gases. Passive ventilation rates are needed for the resolution of several key safety issues. These safety issues are associated with the rates of flammable gas production and ventilation, the rates at which organic salt-nitrate salt mixtures dry out, and the estimation of organic solvent waste surface areas. This tracer gas study involves injecting a tracer gas into the tank headspace and measuring its concentration at different times to establish the rate at which the tracer is removed by ventilation. Tracer gas injection and sample collection were performed by SGN Eurisys Service Corporation and/or Lockheed Martin Hanford Corporation, Characterization Project Operations. Headspace samples were analyzed for He and SF 6 by Pacific Northwest National Laboratory (PNNL). The tracer gas method was first demonstrated on Tank S-102. Tests were conducted on Tank S-102 to verify that the tracer gas was uniformly distributed throughout the tank headspace before baseline samples were collected, and that mixing was sufficiently vigorous to maintain an approximately uniform distribution of tracer gas in the headspace during the course of the study. Headspace samples, collected from a location about 4 in away from the injection point and 15, 30, and 60 minutes after the injection of He and SF 6 , indicated that both tracer gases were rapidly mixed. The samples were found to have the same concentration of tracer gases after 1 hour as after 24 hours, suggesting that mixing of the tracer gas was essentially complete within 1 hour

  9. Aluminium - Cobalt-Pillared Clay for Dye Filtration Membrane

    Science.gov (United States)

    Darmawan, A.; Widiarsih

    2018-04-01

    The manufacture of membrane support from cobalt aluminium pillared clay has been conducted. This research was conducted by mixing a clay suspension with pillared solution prepared from the mixture of Co(NO3)2.6H2O and AlCl3.6H2O. The molar ratio between Al and Co was 75:25 and the ratio of [OH-]/[metal] was 2. The clay suspension was stirred for 24 hours at room temperature, filtered and dried. The dried clay was then calcined at 200°C, 300°C and 400°C with a ramp rate of 2°C/min. Aluminium-cobalt-pillared clay was then characterized by XRD and GSA and moulded become a membrane support for subsequent tests on dye filtration. The XRD analysis showed that basal spacing (d 001) value of aluminium cobalt was 19.49 Å, which was higher than the natural clay of 15.08Å however, the basal spacing decreased with increasing calcination temperature. The result of the GSA analysis showed that the pore diameter of the aluminium cobalt pillared clay membrane was almost the same as that of natural clay that were 34.5Å and 34.2Å, respectively. Nevertheless, the pillared clay has a more uniform pore size distribution. The results of methylene blue filtration measurements demonstrated that the membrane filter support could well which shown by a clear filtrate at all concentrations tested. The value of rejection and flux decreased with the increasing concentration of methylene blue. The values of dye rejection and water flux reached 99.89% and 5. 80 x 10-6 kg min-1, respectively but they decreased with increasing concentration of methylene blue. The results of this study indicates that the aluminium-pillared clay cobalt could be used as membrane materials especially for ultrafiltration.

  10. Scale factor measure method without turntable for angular rate gyroscope

    Science.gov (United States)

    Qi, Fangyi; Han, Xuefei; Yao, Yanqing; Xiong, Yuting; Huang, Yuqiong; Wang, Hua

    2018-03-01

    In this paper, a scale factor test method without turntable is originally designed for the angular rate gyroscope. A test system which consists of test device, data acquisition circuit and data processing software based on Labview platform is designed. Taking advantage of gyroscope's sensitivity of angular rate, a gyroscope with known scale factor, serves as a standard gyroscope. The standard gyroscope is installed on the test device together with a measured gyroscope. By shaking the test device around its edge which is parallel to the input axis of gyroscope, the scale factor of the measured gyroscope can be obtained in real time by the data processing software. This test method is fast. It helps test system miniaturized, easy to carry or move. Measure quarts MEMS gyroscope's scale factor multi-times by this method, the difference is less than 0.2%. Compare with testing by turntable, the scale factor difference is less than 1%. The accuracy and repeatability of the test system seems good.

  11. Process Measurement Deviation Analysis for Flow Rate due to Miscalibration

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Eunsuk; Kim, Byung Rae; Jeong, Seog Hwan; Choi, Ji Hye; Shin, Yong Chul; Yun, Jae Hee [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    An analysis was initiated to identify the root cause, and the exemption of high static line pressure correction to differential pressure (DP) transmitters was one of the major deviation factors. Also the miscalibrated DP transmitter range was identified as another major deviation factor. This paper presents considerations to be incorporated in the process flow measurement instrumentation calibration and the analysis results identified that the DP flow transmitter electrical output decreased by 3%. Thereafter, flow rate indication decreased by 1.9% resulting from the high static line pressure correction exemption and measurement range miscalibration. After re-calibration, the flow rate indication increased by 1.9%, which is consistent with the analysis result. This paper presents the brief calibration procedures for Rosemount DP flow transmitter, and analyzes possible three cases of measurement deviation including error and cause. Generally, the DP transmitter is required to be calibrated with precise process input range according to the calibration procedure provided for specific DP transmitter. Especially, in case of the DP transmitter installed in high static line pressure, it is important to correct the high static line pressure effect to avoid the inherent systematic error for Rosemount DP transmitter. Otherwise, failure to notice the correction may lead to indicating deviation from actual value.

  12. Measurement of gastric emptying rate in humans. Simplified scanning method

    Energy Technology Data Exchange (ETDEWEB)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V. (Univ. of South Carolina School of Medicine, Columbia (USA))

    1990-11-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study.

  13. Measurement of gastric emptying rate in humans. Simplified scanning method

    International Nuclear Information System (INIS)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V.

    1990-01-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study

  14. The stratigraphic filter and bias in measurement of geologic rates

    Science.gov (United States)

    Schumer, Rina; Jerolmack, Douglas; McElroy, Brandon

    2011-01-01

    Erosion and deposition rates estimated from the stratigraphic record frequently exhibit a power-law dependence on measurement interval. This dependence can result from a power-law distribution of stratigraphic hiatuses. By representing the stratigraphic filter as a stochastic process called a reverse ascending ladder, we describe a likely origin of power-law hiatuses, and thus, rate scaling. While power-law hiatuses in certain environments can be a direct result of power-law periods of stasis (no deposition or erosion), they are more generally the result of randomness in surface fluctuations irrespective of mean subsidence or uplift. Autocorrelation in fluctuations can make hiatuses more or less heavy-tailed, but still exhibit power-law characteristics. In addition we show that by passing stratigraphic data backward through the filter, certain statistics of surface kinematics from their formative environments can be inferred.

  15. Transport of micropollutants in a riverbank filtration system

    Science.gov (United States)

    van Driezum, Inge; Oudega, Thomas; Reiner, Philipp; Zessner, Matthias; Farnleitner, Andreas; Blaschke, Paul

    2014-05-01

    Groundwater locations at alluvial backwaters are essential for public water supply. Riverbank filtration (RBF) systems are widely used as a means of obtaining public water supplies. Riverbank filtration is an effective way to remove micropollutants from the receiving surface water. The efficiency of the RBF system strongly depends on the residence time of the water in the aquifer and on the soil properties (Ray, 2011). In order to understand all bio- and geochemical processes within the hyporheic zone (e.g. the region were mixing of surface water and groundwater occurs), exchange rates and flow patterns need to be quantified. The main study area covers the porous groundwater aquifer study site (PGWA) - an urban floodplain extending on the left bank of the River Danube downstream of the City of Vienna. It is one of the main groundwater bodies in Austria. Groundwater quality in the PGWA is influenced by a combination of anthropogenic activities, industry, wastewater treatment plants, heavy precipitation events and floodings. The upper layer of the DPA is impermeable, preventing pollution originating from the surface. The upper layer consists of silt. The underlying confined aquifer consists of sand and gravel layers. Hydraulic conductivities range from 5 x 10-2 m/s up to 5 x 10-5 m/s. Underneath the aquifer are alternating sand an clay/silt layers. Samples are taken from two transects in the DPA. These transects consist of four piezometers in the first few meters of the groundwater aquifer. Several other piezometers are placed downstream from the river-groundwater interface. The behaviour of the micropollutants in the hyporheic zone can therefore be studied intensively. The transport behaviour of several micropollutants is modeled using carbamazepine (CBZ) and acesulfame (ACE) as natural tracers. Furthermore, temperature and electrical conductivity data was used for modeling. The micropollutants are measured using an in house developed online SPE-HPLC-MS/MS method

  16. Accuracy assessment of high-rate GPS measurements for seismology

    Science.gov (United States)

    Elosegui, P.; Davis, J. L.; Ekström, G.

    2007-12-01

    Analysis of GPS measurements with a controlled laboratory system, built to simulate the ground motions caused by tectonic earthquakes and other transient geophysical signals such as glacial earthquakes, enables us to assess the technique of high-rate GPS. The root-mean-square (rms) position error of this system when undergoing realistic simulated seismic motions is 0.05~mm, with maximum position errors of 0.1~mm, thus providing "ground truth" GPS displacements. We have acquired an extensive set of high-rate GPS measurements while inducing seismic motions on a GPS antenna mounted on this system with a temporal spectrum similar to real seismic events. We found that, for a particular 15-min-long test event, the rms error of the 1-Hz GPS position estimates was 2.5~mm, with maximum position errors of 10~mm, and the error spectrum of the GPS estimates was approximately flicker noise. These results may however represent a best-case scenario since they were obtained over a short (~10~m) baseline, thereby greatly mitigating baseline-dependent errors, and when the number and distribution of satellites on the sky was good. For example, we have determined that the rms error can increase by a factor of 2--3 as the GPS constellation changes throughout the day, with an average value of 3.5~mm for eight identical, hourly-spaced, consecutive test events. The rms error also increases with increasing baseline, as one would expect, with an average rms error for a ~1400~km baseline of 9~mm. We will present an assessment of the accuracy of high-rate GPS based on these measurements, discuss the implications of this study for seismology, and describe new applications in glaciology.

  17. Prospects for DNA methods to measure human heritable mutation rates

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.

    1985-01-01

    A workshop cosponsored by ICPEMC and the US Department of Energy was held in Alta, Utah, December 9-13, 1984 to examine the extent to which DNA-oriented methods might provide new approaches to the important but intractable problem of measuring mutation rates in control and exposed human populations. The workshop identified and analyzed six DNA methods for detection of human heritable mutation, including several created at the meeting, and concluded that none of the methods combine sufficient feasibility and efficiency to be recommended for general application. 8 refs

  18. Hanford underground storage tank waste filtration process evaluation

    International Nuclear Information System (INIS)

    Walker, B.W.; McCabe, D.J.

    1997-01-01

    The purpose of this filter study was to evaluate cross-flow filtration as effective solid-liquid separation technology for treating Hanford wastes, outline operating conditions for equipment, examine the expected filter flow rates, and determine proper cleaning. Two Hanford waste processing applications have been identified as candidates for the use of cross-flow filtration. The first of the Hanford applications involves filtration of the decanted supernate from sludge leaching and washing operations. This process involves the concentration and removal of dilute (0.05 wt percent) fines from the bulk of the supernate. The second application involves filtration to wash and concentrate the sludge during out-of-tank processing. This process employs a relatively concentrated (8 wt percent) solids feed stream. Filter studies were conducted with simulants to evaluate whether 0.5 micron cross-flow sintered metal Mott filters and 0.1 micron cross-flow Graver filters can perform solid-liquid separation of the solid/liquid waste streams effectively. In cross-flow filtration the fluid to be filtered flows in parallel to the membrane surface and generates shearing forces and/or turbulence across the filter medium. This shearing influences formation of filter cake stabilizing the filtrate flow rate

  19. Direct measurement of tritium production rate in LiPb with removed parasitic activities: Preliminary experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kuc, Tadeusz, E-mail: kuc@agh.edu.pl; Pohorecki, Władysław; Ostachowicz, Beata

    2014-10-15

    Liquid scintillation (LS) technique applied to direct measurement of tritium activity produced in LiPb eutectic in Frascati HCLL TBM mock-up neutronic experiment has been tested so far in the case of LS measurement after long period since irradiation. LiPb samples irradiated in neutron filed show, except of tritium, meaningful activity of other radioisotopes (parasitic). Parasitic activity, mainly from isotopes of lead ({sup 209}Pb, {sup 204m}Pb, {sup 203}Pb) calculated with the use of FISPACT, exceeds ca 5 times tritium activity 1.4 h after irradiation. We propose to remove disturbing radioisotopes in a chemical way to avoid long “cooling” of the irradiated samples before tritium measurement. Samples (1 g of LiPb) irradiated in reactor fast neutron flux were diluted and metallic cations removed by chemical precipitation. For this purpose we used: potassium iodide (KJ), strontium chloride (SrCl{sub 2}), APDC (C{sub 5}H{sub 8}NS{sub 2}·NH{sub 4}), NaDDTC (C{sub 5}H{sub 10}NNaS{sub 2}·3H{sub 2}O), and PAN (C{sub 15}H{sub 11}N{sub 3}O). Precipitation procedure in each case lasted ca 5–25 min, and the following filtration next 10–20 min. In each filtrate (ca 120 ml) we measured Pb concentration in total reflection X-ray fluorescence (TXRF) analyzer and parasitic activity (left after 21-day “cooling”) applying HPGe gamma spectrometer. Pb cations precipitated by SrCl{sub 2} and than by PAN lowered activity of Pb isotopes to less than 1% of the initial tritium activity. Another combination of reagents: NaDDTC followed by SrCl{sub 2} in a single and double step filtration reduced Pb concentration 10{sup 2} and 10{sup 4} times, respectively. Reduction of this order allows tritium radiometric measurement ca 3 h after irradiation with acceptable accuracy. This time can be shortened by applying correction for decay of known parasitic activity. Input of {sup 76}As and other less abundant radioisotopes can be eliminated using high purity LiPb. Tritium activity of

  20. Device for measuring flow rate in a nuclear reactor core

    International Nuclear Information System (INIS)

    Hamano, Jiro.

    1980-01-01

    Purpose: To always calculate core flow rate automatically and accurately in BWR type nuclear power plants. Constitution: Jet pumps are provided to the recycling pump and to the inside of the pressure vessel of a nuclear reactor. The jet pumps comprise a plurality of calibrated jet pumps for forcively convecting the coolants and a plurality of not calibrated jet pumps in order to cool the heat generated in the reactor core. The difference in the pressures between the upper and the lower portions in both of the jet pumps is measured by difference pressure transducers. Further, a thermo-sensitive element is provided to measure the temperature of recycling water at the inlet of the recycling pump. The output signal from the difference pressure transducer is inputted to a process computer, calculated periodically based on predetermined calculation equations, compensated for the temperature by a recycling water temperature signal and outputted as a core flow rate signal to a recoder. The signal is also used for the power distribution calculation in the process computer and the minimum limit power ratio as the thermal limit value for the fuels is outputted. (Furukawa, Y.)

  1. Lagrangian measurements of sulfur dioxide to sulfate conversion rates

    Energy Technology Data Exchange (ETDEWEB)

    Zak, B D

    1981-12-01

    On the basis of Project MISTT data and proposed homogenous gas phase oxidation mechanisms for sulfur dioxide, it has been suggested that the degree of mixing with background air, the chemical composition of the background air, and the intensity of the sunlight available are key factors determining the rate of sulfur dioxide to sulfate conversion. These hypotheses are examined in light of Lagrangian measrements of conversion rates in power plant plumes made during the Tennessee Plume Study and Project Da Vinci. It is found that the Lagrangian conversion rate measurements are consistent with these hypotheses. It has also been suggested that the concentration of ozone may serve as a workable surrogate for the concentrations of the free radicals involved in the homogeneous gas phase mechanism. The night-time Lagrangian data remind one that the gross difference in mean lifetime of ozone and free radicals can lead to situations in which the ozone concentration is not a good surrogate for the free radical concentrations.

  2. Changes in serum creatinine, uric acid, creatine kinase, and glomerular filtration rate in street runners. http://dx.doi.org/10.5007/1980-0037.2013v15n1p71

    Directory of Open Access Journals (Sweden)

    Anderson Pontes Morales

    2013-01-01

    Full Text Available The strategies adopted by street runners during races are influenced by the distance of the race as well as the technical and physical condition levels of the runners. The objective of this study was to examine the biochemical effects of Creatinine (C, Uric Acid (UA, Creatine Kinase (CK, and of the Glomerular Filtration Rate (GFR caused by a 6-kilometer street race. The participants (n=15 were all male athletes (40.53±8.65 years and were divided into 3 groups: Group 1 Best Times (G1MT n=5, Group 2 Intermediate Times (G2TI n=5, Group 3 Worst Times (G3PT n=5. Blood samples were collected 30 minutes before and immediately after the race. The data was analyzed by Two-Way ANOVA, Wilcoxon, and Mann Whitney. Significant levels were considered as (p<0.05. The results showed that there were significant intragroup increases in serum activities of (C in G1MT pre: 1.18±0.04 mg.dL-¹ post: 1.60±0.15 mg.dL-¹; G2TI pre: 1.04±0.15 mg.dL-¹ post: 1.56±0.21 mg.dL-¹; G3PT pre 1.08±0.13 mg.dL-¹ post 1.52±0.32 mg.dL-¹, and in (AU G1MT pre: 3.80±0.75 mg.dL-¹ post 4.56±0.94 mg.dL-¹; G2TI pre 4.36±1.62 mg.dL-¹ post 5.0±1.69 mg.dL-¹; G3PT pre 4.62±1.08 mg.dL-¹ post: 5.42±0.86 mg.dL-¹, while CK and GFR did not show any significant difference.

  3. Variability in the measurement of hospital-wide mortality rates.

    Science.gov (United States)

    Shahian, David M; Wolf, Robert E; Iezzoni, Lisa I; Kirle, Leslie; Normand, Sharon-Lise T

    2010-12-23

    Several countries use hospital-wide mortality rates to evaluate the quality of hospital care, although the usefulness of this metric has been questioned. Massachusetts policymakers recently requested an assessment of methods to calculate this aggregate mortality metric for use as a measure of hospital quality. The Massachusetts Division of Health Care Finance and Policy provided four vendors with identical information on 2,528,624 discharges from Massachusetts acute care hospitals from October 1, 2004, through September 30, 2007. Vendors applied their risk-adjustment algorithms and provided predicted probabilities of in-hospital death for each discharge and for hospital-level observed and expected mortality rates. We compared the numbers and characteristics of discharges and hospitals included by each of the four methods. We also compared hospitals' standardized mortality ratios and classification of hospitals with mortality rates that were higher or lower than expected, according to each method. The proportions of discharges that were included by each method ranged from 28% to 95%, and the severity of patients' diagnoses varied widely. Because of their discharge-selectio