WorldWideScience

Sample records for fill tube experiments

  1. Modeling and experiments with low-frequency pressure wave propagation in liquid-filled, flexible tubes

    DEFF Research Database (Denmark)

    Bjelland, C; Bjarnø, Leif

    1992-01-01

    A model for wave propagation in a liquid-filled viscoelastic tube with arrays of receivers inside, is being used to analyze the influence of noise generated by in-line vibrational noise sources. In this model, distensibility is of greater importance than compressibility of the liquid....... The dispersion and attenuation is shown to be strongly dependent on the viscoelastic properties of the tube wall. The complex, frequency-dependent moduli of relevant tube materials have been measured in stress wave transfer function experiments. The moduli are used in the model to produce realistic dispersion...... relations and frequency-dependent attenuation. A 12-m-long, liquid-filled tube with interior stress members and connectors in each end is hanging vertically from an upper fixture. The lower end connector is excited by a power vibrator to generate the relevant wave modes. Measurements with reference...

  2. Fill tube fitted spheres

    International Nuclear Information System (INIS)

    Ives, B.H.

    1981-01-01

    The high temperature diffusion technique for fuel filling of some future direct drive cryogenic ICF targets may be unacceptable. The following describes a technique of fitting a 1 mm diameter x 6 μm thick glass microsphere with an approx. 50 μm O.D. glass fill tube. The process of laser drilling a 50 μm diameter hole in the microsphere wall, technique for making the epoxy joint between the sphere and fill tube, as well as the assembly procedure are also discussed

  3. Design options for reducing the impact of the fill-tube in ICF implosion experiments on the NIF

    Science.gov (United States)

    Weber, Christopher R.; Berzak Hopkins, L. F.; Casey, D. T.; Clark, D. S.; Hammel, B. A.; Le Pape, S.; Macphee, A.; Milovich, J.; Pickworth, L. A.; Robey, H. F.; Smalyuk, V. A.; Stadermann, M.; Felker, S. J.; Nikroo, A.; Thomas, C. A.; Crippen, J.; Rice, N.

    2017-10-01

    Inertial Confinement Fusion (ICF) capsules on the National Ignition Facility (NIF) are filled with thermonuclear fuel through a fill-tube. When the capsule implodes, perturbations caused by the fill-tube allow ablator material to mix into the hot spot and reduce fusion performance. This talk will explore several design options that attempt to reduce this damaging effect. Reducing the diameter of the fill-tube and its entrance hole is the obvious course and has been tested in experiments. Simulations also show sensitivity to the amount of glue holding the fill-tube to the capsule and suggest that careful control of this feature can limit the amount of injected mass. Finally, an off-axis fill-tube reduces the initial squirt of material into the fuel and may be a way of further optimizing this engineering feature. Work performed under the auspices of the U.S. D.O.E. by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  4. 3D integrated HYDRA simulations of hohlraums including fill tubes

    Science.gov (United States)

    Marinak, M. M.; Milovich, J.; Hammel, B. A.; Macphee, A. G.; Smalyuk, V. A.; Kerbel, G. D.; Sepke, S.; Patel, M. V.

    2017-10-01

    Measurements of fill tube perturbations from hydro growth radiography (HGR) experiments on the National Ignition Facility show spoke perturbations in the ablator radiating from the base of the tube. These correspond to the shadow of the 10 μm diameter glass fill tube cast by hot spots at early time. We present 3D integrated HYDRA simulations of these experiments which include the fill tube. Meshing techniques are described which were employed to resolve the fill tube structure and associated perturbations in the simulations. We examine the extent to which the specific illumination geometry necessary to accommodate a backlighter in the HGR experiment contributes to the spoke pattern. Simulations presented include high resolution calculations run on the Trinity machine operated by the Alliance for Computing at Extreme Scale (ACES) partnership. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.

  5. Endurance of Damping Properties of Foam-Filled Tubes

    Directory of Open Access Journals (Sweden)

    Matteo Strano

    2015-07-01

    Full Text Available The favorable energy-absorption properties of metal foams have been frequently proposed for damping or anti-crash applications. The aim of this paper is to investigate the endurance of these properties for composite structures, made by a metal or a hybrid metal-polymeric foam used as the core filling of a tubular metal case. The results of experimental tests are shown, run with two types of structures: 1 square steel tubes filled with aluminum or with hybrid aluminum-polymer foams; 2 round titanium tubes filled with aluminum foams. The paper shows that the damping properties of a foam-filled tube change (improve with the number of cycles, while all other dynamic properties are nearly constant. This result is very important for several potential applications where damping is crucial, e.g., for machine tools.

  6. Endurance of Damping Properties of Foam-Filled Tubes.

    Science.gov (United States)

    Strano, Matteo; Marra, Alessandro; Mussi, Valerio; Goletti, Massimo; Bocher, Philippe

    2015-07-07

    The favorable energy-absorption properties of metal foams have been frequently proposed for damping or anti-crash applications. The aim of this paper is to investigate the endurance of these properties for composite structures, made by a metal or a hybrid metal-polymeric foam used as the core filling of a tubular metal case. The results of experimental tests are shown, run with two types of structures: 1) square steel tubes filled with aluminum or with hybrid aluminum-polymer foams; 2) round titanium tubes filled with aluminum foams. The paper shows that the damping properties of a foam-filled tube change (improve) with the number of cycles, while all other dynamic properties are nearly constant. This result is very important for several potential applications where damping is crucial, e.g., for machine tools.

  7. Shock tube Multiphase Experiments

    Science.gov (United States)

    Middlebrooks, John; Allen, Roy; Paudel, Manoj; Young, Calvin; Musick, Ben; McFarland, Jacob

    2017-11-01

    Shock driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching practical applications in engineering and science. The instability is present in high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase interface is impulsively accelerated by the passage of a shockwave. It is similar in development to the Richtmyer-Meshkov (RM) instability however, particle-to-gas coupling is the driving mechanism of the SDMI. As particle effects such as lag and phase change become more prominent, the SDMI's development begins to significantly deviate from the RM instability. We have developed an experiment for studying the SDMI in our shock tube facility. In our experiments, a multiphase interface is created using a laminar jet and flowed into the shock tube where it is accelerated by the passage of a planar shockwave. The interface development is captured using CCD cameras synchronized with planar laser illumination. This talk will give an overview of new experiments conducted to examine the development of a shocked cylindrical multiphase interface. The effects of Atwood number, particle size, and a second acceleration (reshock) of the interface will be discussed.

  8. On Love's approximation for fluid-filled elastic tubes

    International Nuclear Information System (INIS)

    Caroli, E.; Mainardi, F.

    1980-01-01

    A simple procedure is set up to introduce Love's approximation for wave propagation in thin-walled fluid-filled elastic tubes. The dispersion relation for linear waves and the radial profile for fluid pressure are determined in this approximation. It is shown that the Love approximation is valid in the low-frequency regime. (author)

  9. Preservative loss from silicone tubing during filling processes.

    Science.gov (United States)

    Saller, Verena; Matilainen, Julia; Rothkopf, Christian; Serafin, Daniel; Bechtold-Peters, Karoline; Mahler, Hanns-Christian; Friess, Wolfgang

    2017-03-01

    Significant loss of preservative was observed during filling of drug products during filling line stops. This study evaluated the losses of three commonly used preservatives in protein drugs, i.e. benzyl alcohol, phenol, and m-cresol. Concentration losses during static incubation were quantified and interpreted with regard to the potential driving forces for the underlying sorption, diffusion, and desorption steps. Partitioning from the solution into the silicone polymer was identified as the most decisive parameter for the extent of preservative loss. Additionally, the influence of tubing inner diameter, starting concentration as well as silicone tubing type was evaluated. Theoretical calculations assuming equilibrium between solution and tubing inner surface and one-directional diffusion following Fick's first law were used to approximate experimental data. Since significant losses were found already after few minutes, adequate measures must be taken to avoid deviations during filling of preservative-containing protein solutions that may impact product quality or antimicrobial efficacy. As a possible alternative to the highly permeable silicone tubing, a specific make of fluoropolymer tubing was identified being suitable for peristaltic pumps and not showing any preservative losses. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A reevaluation of fluid flow, heat transfer and chemical reaction in catalyst filled tubes

    OpenAIRE

    Daszkowski, Thomas; Eigenberger, Gerhart

    1992-01-01

    The problem of heat transfer through the wall in catalyst filled tubes with a tube to particle diameter ratio greater than 4 - 5 and industrial flow rates with and without chemical reaction has been reevaluated through detailed experiments and model calculations. The results confirm and extend findings of Vortmeyer et al. that reaction and heat transfer can only be modeled with independently determined parameters if the radial variation of the axial mass flow velocity is properly considered. ...

  11. Ion beam characteristics of a gas filled accelerator tube

    International Nuclear Information System (INIS)

    Berg, R.S.; Bickes, R.W. Jr.; Boers, J.E.; Shope, L.A.

    1980-01-01

    A gas filled tube used to produce a pulsed neutron flux with the D(T, 4 He)n reaction is described. Deuterium and tritium ions generated in a reflex discharge are extracted and accelerated to 100 keV by means of an accelerator electrode onto a deutero-tritide target electrode. The electrodes are designed to focus the ion beam onto the target. Total tube currents consisting of extracted ions, unsuppressed secondary electrons, and ions generated by interactions with the background gas are typically 100mA. Characteristics of the extracted ion beam are discussed. Accelerating voltages greater than 50kV are required to focus the beam through the accelerator aperture for configurations that give beams with the proper energy density at the target. The perveance of the beam is defined. Maximum perveance values are 2 to 10 nanopervs. Tube focussing and neutron production characteristics are described

  12. Bearing Capacities of Different-Diameter Concrete-Filled Steel Tubes under Axial Compression

    Directory of Open Access Journals (Sweden)

    Wenjing Wang

    2016-01-01

    Full Text Available The bearing capacities of concrete-filled steel tubes are normally derived through experiments with small-scale specimens, but it is uncertain whether such derivations are appropriate for the much larger components used in practical engineering. This study therefore investigates the effect of different diameters (219, 426, 630, and 820 mm on the axial compression of short concrete columns in steel (Q235 tubes. It is found that the peak nominal stress decreases with increasing specimen size and that the axial bearing capacity is determined by three separate components: the cylinder compressive strength of the concrete, the improvement in strength due to the confining effect of the steel tube, and the longitudinal strength of the steel tube. At peak load, increases in the specimen diameter reduce the hoop stresses in the steel tube, thereby reducing the strengthening effect of confinement. Vertical stress in the steel tube is increased with diameter; therefore, the axial bearing capacity of the steel tube is directly related to the specimen size. Size effect coefficients for these three aspects of bearing capacity are defined and used to develop a size-dependent model for predicting the axial bearing capacity of large, concrete-filled steel tubes. The model is then validated against experimental data.

  13. Concrete-Filled Steel Tube Arch Bridges in China

    Directory of Open Access Journals (Sweden)

    Jielian Zheng

    2018-02-01

    Full Text Available In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has been increasing rapidly, which is rare in the history of bridge development. The large-scale construction of expressways and high-speed railways demands the development of long-span arch bridges, and advances in design and construction techniques have made it possible to construct such bridges. In the present study, the current status, development, and major innovative technologies of CFST arch bridges and concrete arch bridges with a CFST skeleton in China are elaborated. This paper covers the key construction technologies of CFST arch bridges, such as the design, manufacture, and installation of steel tube arch trusses, the preparation and pouring of in-tube concrete, and the construction of the world’s longest CFST arch bridge—the First Hejiang Yangtze River Bridge. The main construction technologies of reinforced concrete arch bridges are also presented, which include cable-stayed fastening-hanging cantilever assembly, adjusting the load by means of stay cables, surrounding the concrete for arch rib pouring, and so forth. In addition, the construction of two CFST skeleton concrete arch bridges—the Guangxi Yongning Yong River Bridge and the Yunnan–Guangxi Railway Nanpan River Bridge—is discussed. CFST arch bridges in China have already gained a world-leading position; with the continuous innovation of key technologies, China will become the new leader in promoting the development of arch bridges. Keywords: Concrete-filled steel tube (CFST arch bridge, Steel-reinforced concrete arch bridge, Cable-stayed fastening-hanging cantilever assembly, Vacuum-assisted pouring in-tube concrete, Adjusting load by stay cables

  14. Kundt's Tube Experiment Using Smartphones

    Science.gov (United States)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2015-01-01

    This article deals with a modern version of Kundt's tube experiment. Using economic instruments and a couple of smartphones, it is possible to "see" nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  15. Determination of absorption coefficient based on laser beam thermal blooming in gas-filled tube.

    Science.gov (United States)

    Hafizi, B; Peñano, J; Fischer, R; DiComo, G; Ting, A

    2014-08-01

    Thermal blooming of a laser beam propagating in a gas-filled tube is investigated both analytically and experimentally. A self-consistent formulation taking into account heating of the gas and the resultant laser beam spreading (including diffraction) is presented. The heat equation is used to determine the temperature variation while the paraxial wave equation is solved in the eikonal approximation to determine the temporal and spatial variation of the Gaussian laser spot radius, Gouy phase (longitudinal phase delay), and wavefront curvature. The analysis is benchmarked against a thermal blooming experiment in the literature using a CO₂ laser beam propagating in a tube filled with air and propane. New experimental results are presented in which a CW fiber laser (1 μm) propagates in a tube filled with nitrogen and water vapor. By matching laboratory and theoretical results, the absorption coefficient of water vapor is found to agree with calculations using MODTRAN (the MODerate-resolution atmospheric TRANsmission molecular absorption database) and HITRAN (the HIgh-resolution atmospheric TRANsmission molecular absorption database).

  16. Strain limits for concrete filled steel tubes in AASHTO seismic provisions.

    Science.gov (United States)

    2013-08-01

    Reinforced concrete filled steel tubes (RCFSTs) are commonly used as bridge pipe piles in high seismic regions. The pipe piles in high : seismic regions. The pipe-piles consist of reinforced concrete encased in a steel tube. The steel tube is used as...

  17. Behavior of FRP-Confined Concrete-Filled Steel Tube Columns

    Directory of Open Access Journals (Sweden)

    Yiyan Lu

    2014-05-01

    Full Text Available This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP. Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap can effectively confine the concrete expansion and delay the local buckling of the steel tube. Both the load capacity and the axial deformation capacity of concrete-filled steel tube columns can be substantially enhanced with FRP confinement. A model is proposed to predict the load capacity of the FRP-confined concrete-filled steel tube columns. The predicted results are generally in good agreement with the experimental ones obtained in this study and in the literature.

  18. Fabrication of Aluminum Tubes Filled with Aluminum Alloy Foam by Friction Welding

    Directory of Open Access Journals (Sweden)

    Yoshihiko Hangai

    2015-10-01

    Full Text Available Aluminum foam is usually used as the core of composite materials by combining it with dense materials, such as in Al foam core sandwich panels and Al-foam-filled tubes, owing to its low tensile and bending strengths. In this study, all-Al foam-filled tubes consisting of ADC12 Al-Si-Cu die-cast aluminum alloy foam and a dense A1050 commercially pure Al tube with metal bonding were fabricated by friction welding. First, it was found that the ADC12 precursor was firmly bonded throughout the inner wall of the A1050 tube without a gap between the precursor and the tube by friction welding. No deformation of the tube or foaming of the precursor was observed during the friction welding. Next, it was shown that by heat treatment of an ADC12-precursor-bonded A1050 tube, gases generated by the decomposition of the blowing agent expand the softened ADC12 to produce the ADC12 foam interior of the dense A1050 tube. A holding time during the foaming process of approximately tH = 8.5 min with a holding temperature of 948 K was found to be suitable for obtaining a sound ADC12-foam-filled A1050 tube with sufficient foaming, almost uniform pore structures over the entire specimen, and no deformation or reduction in the thickness of the tube.

  19. Process and device for subdividing a glass tube filled with a radioactive gas

    International Nuclear Information System (INIS)

    Caffarella, T.E.; Radda, G.J.; Watts, D.J.

    1977-01-01

    A process is described for subdividing into individual sealed segments an elongated glass tube coated internally with a luminescent material and filled with a radioactive gas, this tube having a longitudinal axis. It consists in directing a focused laser beam on to the surface of the tube in an ambient atmosphere with a pressure greater than that of the gas in the tube and to create a relative, repetitive and alternating movement between the laser beam and the surface of the tube. This movement is transversal to the longitudinal axis of the tube, so as to heat and soften the tube along a cutting line until the tube divides and presents new ends where it contracts, causing these ends to seal up [fr

  20. Experimental Investigation of Concrete Filled PVC Tube Columns Confined By Plain PVC Socket

    OpenAIRE

    Jamaluddin N.; Azeez A. A.; Abd Rahman N.; Attiyah A. N.; Wan Ibrahim M. H.; Mohamad N.; Adnan S. H.

    2017-01-01

    This paper presents results of an experimental study for concrete column filled poly vinyl chloride (PVC) tubes confined by plain socket with 5.8 & 6.8 mm thicknesses, 102 mm diameter and 100 mm depth. The total of five concrete filled columns using PVC tubes (CFT PVC) was tested to investigate the columns’ behaviour. The column is 700 mm height, 100 mm external diameter and 3.5 mm tube thickness with different thickness of plain socket. The results presented include maximum axial load, plain...

  1. Multi objective optimization of foam-filled circular tubes for quasi-static and dynamic responses

    Directory of Open Access Journals (Sweden)

    Fauzan Djamaluddin

    Full Text Available AbstractFuel consumption and safety are currently key aspects in automobile design. The foam-filled thin-walled aluminium tube represents a potentially effective material for use in the automotive industry, due to its energy absorption capability and light weight. Multi-objective crashworthiness design optimization for foam-filled double cylindrical tubes is presented in this paper. The double structures are impacted by a rigid wall simulating quasi-static and dynamic loadings. The optimal parameters under consideration are the minimum peak crushing force and maximum specific energy absorption, using the non-dominated sorting genetic algorithm-II (NSGA-II technique. Radial basis functions (RBF and D-Optimal are adopted to determine the more complex crashworthiness functional objectives. The comparison is performed by finite element analysis of the impact crashworthiness characteristics in tubes under static and dynamic loads. Finally, the optimum crashworthiness performance of empty and foam-filled double tubes is investigated and compared to the traditional single foam-filled tube. The results indicate that the foam-filled double aluminium circular tube can be recommended for crashworthy structures.

  2. Self-sensing concrete-filled FRP tubes using FBG strain sensors

    Science.gov (United States)

    Yan, Xin; Li, Hui

    2007-07-01

    Concrete-filled fiber-reinforced polymer (FRP) tube is a type of newly developed structural column. It behaves brittle failure at its peak strength, and so the health monitoring on the hoop strain of the FRP tube is essential for the life cycle safety of the structure. Herein, three types of FRP tubes including 5-ply tube, 2-ply tube with local reinforcement and FRP-steel composite tube were embedded with the optic fiber Bragg grating (FBG) strain sensors in the inter-ply of FRP or the interface between FRP and steel in the middle height and the hoop direction. The compressive behaviors of the concrete-filled FRP tubes were experimentally studied. The hoop strains of the FRP tubes were recorded in real time using the embedded FBG strain sensors as well as the embedded or surface electric resistance strain gauges. Results indicated that the FBG strain sensors can faithfully record the hoop strains of the FRP tubes in compression as compared with the embedded or surface electric resistance strain gauges, and the strains recorded can reach more than μɛ.

  3. Behavior of Hollow Thin Welded Tubes Filled with Sand Slag Concrete

    Directory of Open Access Journals (Sweden)

    Noureddine Ferhoune

    2016-01-01

    Full Text Available This paper presents the axial bearing capacity of thin welded rectangular steel stubs filled with concrete sand. A series of tests was conducted to study the behavior of short composite columns under axial compressive load; the cross section dimensions were 100 × 70 × 2 mm. A total of 20 stubs have been tested, as follows: 4 hollow thin welded tubes were tested to axial and eccentric load compression, 4 were filled with ordinary concrete appointed by BO columns, 6 were filled with concrete whose natural sand was completely substituted by a crystallized sand slag designated in this paper by BSI, and 6 were tucked in concrete whose natural sand was partially replaced by a crystallized sand slag called BSII. The main parameters studied are the height of the specimen (300 mm–500 mm, eccentricity of load and type of filling concrete. Based on test results obtained, it is confirmed that the length of the tubes has a considerable effect on the bearing capacity and the failure mode. In all test tubes, fracture occurred by the convex local buckling of steel section due to the outward thrust of the concrete; it was observed that the sand concrete improves the bearing capacity of tubes compounds compared to those filled with ordinary concrete.

  4. Self-sensing concrete-filled FRP tube using FBG strain sensor

    Science.gov (United States)

    Yan, Xin; Li, Hui

    2007-01-01

    Concrete-filled fiber-reinforced polymer (FRP) tube is a type of newly developed structural column. It behaves brittle failure at its peak strength, and so the health monitoring on the hoop strain of the FRP tube is essential for the life cycle safety of the structure. Herein, the optic fiber Bragg grating (FBG) strain sensor was chosen as the strain measuring gauge and embedded in the inter-ply of fibers in the middle height and the hoop direction of the FRP tube. The compressive behaviors of the concrete-filled FRP tubes were experimentally studied. The hoop strain of the FRP tube was recorded in real time using the embedded FBG strain sensor as well as the embedded or surface electric resistance strain gauges. Results indicated that the FBG strain sensor can faithfully record the hoop strain ofthe concrete-filled FRP tubes in compression as compared with the embedded or surface electric resistance strain gauges, and the strain recorded can reach more than 7000μɛ.

  5. Experimental research on fire resistance of circular steel tube column filled with steel-reinforced high-strength concrete

    Directory of Open Access Journals (Sweden)

    ZHU Siyi

    2014-06-01

    Full Text Available Circular steel tube filled with steel-reinforced high-strength concrete is a new model of composite column design.The fire resistance of this composite column was investigated experimentally.One circular steel tube column filled with steel-reinforced high-strength concrete and one circular steel tube column filled with high- strength concrete were tested under axial load and fire.The test results show that the axial deformations of both kinds of the composite columns under the same load level have experienced three stages variation:the initial expansion deformation stage,the compression deformation gradual growth stage and the damage stage with the dramatic increasing in compression deformation.The second compression stable development stage of the circular steel tube filled with steel-reinforced high-strength concrete is much longer than that of the circular steel tube column filled with high-strength concrete.Thus the fire endurance of the circular steel tube filled with steel-reinforced high-strength concrete reaches 166 minutes while the fire endurance of the circular steel tube column filled with high-strength concrete only reaches 46 minutes.Thus encasig section steel can remarkably improve the fire endurance of the circular steel tube filled with high-strength concrete.The research results can provide beneficial reference for the fire design of circular steel tube composite columns filled with steel-reinforced concrete.

  6. Experimental study on mechanical behavior of shear connectors of square concrete filled steel tube

    NARCIS (Netherlands)

    Qiao, Qiyun; Zhang, Wenwen; Qian, Zhiwei; Cao, Wanlin; Liu, Wenchao

    2017-01-01

    In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen

  7. Experimental Investigation of Concrete Filled PVC Tube Columns Confined By Plain PVC Socket

    Directory of Open Access Journals (Sweden)

    Jamaluddin N.

    2017-01-01

    Full Text Available This paper presents results of an experimental study for concrete column filled poly vinyl chloride (PVC tubes confined by plain socket with 5.8 & 6.8 mm thicknesses, 102 mm diameter and 100 mm depth. The total of five concrete filled columns using PVC tubes (CFT PVC was tested to investigate the columns’ behaviour. The column is 700 mm height, 100 mm external diameter and 3.5 mm tube thickness with different thickness of plain socket. The results presented include maximum axial load, plain socket confinement effect, the mode of failure, and lateral PVC strain. The axial load enhancement of PVC-concrete columns confined using plain socket shows an increment of 21.3% up to 55.2% and axial strain from 21% to 40% compared with displacement for control composite columns at 192 kN ultimate load.

  8. Local Buckling of Axially Compressed Rectangular Concrete-Filled Steel Tubes

    Directory of Open Access Journals (Sweden)

    Kanishchev Ruslan

    2016-01-01

    Full Text Available The article deals with the theoretical analysis of the local stability of contemporary structures such as rectangular concrete-filled steel tubes (CFST’s without imperfections. The work presents a numerical method for calculating the coefficient of critical stress by differential equation for slender walls of hollow and concrete filled closed right-angled profiles. The results of the method were compared with the modelled results of the construction elements in ABAQUS software. Based on this theoretical analysis, the direction of future research has been determined, which will focus on the impact of local stability on the cross-section of rectangular CFSTs in terms of their resistance.

  9. A unified formulation for circle and polygon concrete-filled steel tube columns under axial compression

    OpenAIRE

    Yu, Min; Zha, Xiaoxiong; Ye, Jianqiao; Li, Yuting

    2013-01-01

    Current design practice of concrete-filled steel tube (CFST) columns uses different formulas for different section profiles to predict the axial load bearing capacity. It has always been a challenge and practically important issue for researchers and design engineers who want to find a unified formula that can be used in the design of the columns with various sections, including solid, hollow, circular and polygonal sections. This has been driven by modern design requirements for continuous o...

  10. Fabrication of Aluminum Foam-Filled Thin-Wall Steel Tube by Friction Welding and Its Compression Properties

    Directory of Open Access Journals (Sweden)

    Yoshihiko Hangai

    2014-09-01

    Full Text Available Aluminum foam has received considerable attention in various fields and is expected to be used as an engineering material owing to its high energy absorption properties and light weight. To improve the mechanical properties of aluminum foam, combining it with dense tubes, such as aluminum foam-filled tubes, was considered necessary. In this study, an aluminum foam-filled steel tube, which consisted of ADC12 aluminum foam and a thin-wall steel tube, was successfully fabricated by friction welding. It was shown that a diffusion bonding layer with a thickness of approximately 10 μm was formed, indicating that strong bonding between the aluminum foam and the steel tube was realized. By the X-ray computed tomography observation of pore structures, the fabrication of an aluminum foam-filled tube with almost uniform pore structures over the entire specimen was confirmed. In addition, it was confirmed that the aluminum foam-filled steel tube exhibited mechanical properties superior to those of the ADC12 aluminum foam and steel tube. This is considered to be attributed to the combination of the aluminum foam and steel tube, which particularly prevents the brittle fracture and collapse of the ADC12 foam by the steel tube, along with the strong metal bonding between the aluminum foam and the steel tube.

  11. Fabrication of Aluminum Foam-Filled Thin-Wall Steel Tube by Friction Welding and Its Compression Properties.

    Science.gov (United States)

    Hangai, Yoshihiko; Saito, Masaki; Utsunomiya, Takao; Kitahara, Soichiro; Kuwazuru, Osamu; Yoshikawa, Nobuhiro

    2014-09-19

    Aluminum foam has received considerable attention in various fields and is expected to be used as an engineering material owing to its high energy absorption properties and light weight. To improve the mechanical properties of aluminum foam, combining it with dense tubes, such as aluminum foam-filled tubes, was considered necessary. In this study, an aluminum foam-filled steel tube, which consisted of ADC12 aluminum foam and a thin-wall steel tube, was successfully fabricated by friction welding. It was shown that a diffusion bonding layer with a thickness of approximately 10 μm was formed, indicating that strong bonding between the aluminum foam and the steel tube was realized. By the X-ray computed tomography observation of pore structures, the fabrication of an aluminum foam-filled tube with almost uniform pore structures over the entire specimen was confirmed. In addition, it was confirmed that the aluminum foam-filled steel tube exhibited mechanical properties superior to those of the ADC12 aluminum foam and steel tube. This is considered to be attributed to the combination of the aluminum foam and steel tube, which particularly prevents the brittle fracture and collapse of the ADC12 foam by the steel tube, along with the strong metal bonding between the aluminum foam and the steel tube.

  12. Ion beam characteristics of the controlatron/zetatron family of the gas filled neutron tubes

    Energy Technology Data Exchange (ETDEWEB)

    Berg, R.S.; Shope, L.A.; O' Neal, M.L.; Boers, J.E.; Bickes, R.W. Jr.

    1981-03-01

    A gas filled tube used to produce a neutron flux with the D(T,He/sup 4/)n reaction is described. Deuterium and tritium ions generated in a reflex discharge are extracted and accelerated to 100 keV by means of an accelerator electrode onto a deutero-tritide target electrode. The electrodes are designed to focus the ion beam onto the target. Total tube currents consisting of extracted ions, unsuppressed secondary electrons, and ions generated by interactions with the background gas are typically 100 mA. The characteristics of the extracted ion beam are discussed. Accelerating voltages greater than 50 kV are required to focus the beam through the accelerator aperture for configurations that give beams with the proper energy density onto the target. The perveance of the beam is discussed. Maximum perveance values are 2 to 20 nanopervs. Tube focusing and neutron production characteristics are described.

  13. Kundt’s tube experiment using smartphones

    Science.gov (United States)

    Orsola Parolin, Sara; Pezzi, Giovanni

    2015-07-01

    This article deals with a modern version of Kundt’s tube experiment. Using economic instruments and a couple of smartphones, it is possible to ‘see’ nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  14. Experimental research on fire resistance of circular steel tube column filled with steel-reinforced high-strength concrete

    OpenAIRE

    ZHU Siyi; ZHU Meichun; ZHENG Lilan; YANG Jinghua; WANG Lvyi

    2014-01-01

    Circular steel tube filled with steel-reinforced high-strength concrete is a new model of composite column design.The fire resistance of this composite column was investigated experimentally.One circular steel tube column filled with steel-reinforced high-strength concrete and one circular steel tube column filled with high- strength concrete were tested under axial load and fire.The test results show that the axial deformations of both kinds of the composite columns under the same load level...

  15. Experimental Study on Ultrahigh Strength Concrete Filled Steel Tube Short Columns under Axial Load

    Directory of Open Access Journals (Sweden)

    Xiaojun Zhou

    2017-01-01

    Full Text Available Based on the project of Modaoxi Bridge, an experimental study on the compressive behavior of ultrahigh strength concrete filled steel tube (UHSCFST short column was conducted. A total of 9 UHSCFST specimens were tested, and the cube strength (fcu of the core concrete reached 115.4 MPa. Main parameters were the confining factor (ξ=0.608, 0.919, and 1.015, steel ratio (α=14.67%, 20.02%, and 21.98%, and steel strength (fy = 349 MPa, 352 MPa, and 427 MPa. The axially loading test results showed that the visible damage of steel tube occurred under the ultimate load. The higher the confining effect, the less the damage features. And all specimens basically presented a drum-type failure mode. The confining effect of steel tube effectively changed the brittle failure mode of ultrahigh strength concrete (UHSC and tremendously improved the load bearing capacity and ductility of specimens. Moreover, the higher the steel ratio and steel strength of the specimens, the stronger the confining effect. Meanwhile the excellent mechanical properties will be obtained. Also it is recommended that the UHSCFST prefers Q345 or above strength steel tube to ensure sufficient ductility, and the steel ratio should be more than 20%. Furthermore, the confining effect of steel tubes can improve the ultimate bearing capacity of the ultrahigh strength CFST short columns.

  16. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  17. Seismic performance of recycled concrete-filled square steel tube columns

    Science.gov (United States)

    Chen, Zongping; Jing, Chenggui; Xu, Jinjun; Zhang, Xianggang

    2017-01-01

    An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.

  18. Effect of Concrete Age and Creep on the Behavior of Concrete-Filled Steel Tube Columns

    Directory of Open Access Journals (Sweden)

    HaiYang Wang

    2016-01-01

    Full Text Available The influence of concrete age and creep on the ultimate axial loading capacity of concrete-filled steel tube (CFST columns is experimentally and numerically investigated. After validation of numerical models, a parametric study is conducted and the results are used to formulate empirical formulas for predicting the ultimate axial load-bearing capacity of the columns. Formulas are also proposed for predicting both the composite creep and aging coefficients of the CFST columns, which consider the confinement action of steel tubes on concrete. Then, the proposed formulas are validated independently by comparing their predictions with existing test results performed by other researchers. The comparisons show that the empirical formulas have the potential to be used in the practical design of CFST columns.

  19. Buckling of Slender Concrete-Filled Steel Tubes with Compliant Interfaces

    Directory of Open Access Journals (Sweden)

    Simon Schnabl

    Full Text Available Abstract This paper presents an exact model for studying the global buckling of concrete-filled steel tubular (CFST columns with compliant interfaces between the concrete core and steel tube. This model is then used to evaluate exact critical buckling loads and modes of CFST columns. The results prove that interface compliance can considerably reduce the critical buckling loads of CFST columns. A good agreement between analytical and experimental buckling loads is obtained if at least one among longitudinal and radial interfacial stiffnesses is high. The parametric study reveals that buckling loads of CFST columns are very much affected by the interfacial stiffness and boundary conditions.

  20. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    International Nuclear Information System (INIS)

    Buice, E.S.; Alger, E.T.; Antipa, N.A.; Bhandarkar, S.D.; Biesiada, T.A.; Conder, A.D.; Dzenitis, E.G.; Flegel, M.S.; Hamza, A.V.; Heinbockel, C.L.; Horner, J.; Johnson, M.A.; Kegelmeyer, L.M.; Meyer, J.S.; Montesanti, R.C.; Reynolds, J.L.; Taylor, J.S.; Wegner, P.J.

    2011-01-01

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 (micro)m diameter glass-core fill-tube that tapers down to a 10(micro) diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1σ), which corresponds to approximately 5 (micro)m linear error on the capsule surface.

  1. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    Energy Technology Data Exchange (ETDEWEB)

    Buice, E S; Alger, E T; Antipa, N A; Bhandarkar, S D; Biesiada, T A; Conder, A D; Dzenitis, E G; Flegel, M S; Hamza, A V; Heinbockel, C L; Horner, J; Johnson, M A; Kegelmeyer, L M; Meyer, J S; Montesanti, R C; Reynolds, J L; Taylor, J S; Wegner, P J

    2011-02-18

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 {micro}m diameter glass-core fill-tube that tapers down to a 10{micro} diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1{sigma}), which corresponds to approximately 5 {micro}m linear error on the capsule surface.

  2. Experiments with Helium-Filled Balloons

    Science.gov (United States)

    Zable, Anthony C.

    2010-01-01

    The concepts of Newtonian mechanics, fluids, and ideal gas law physics are often treated as separate and isolated topics in the typical introductory college-level physics course, especially in the laboratory setting. To bridge these subjects, a simple experiment was developed that utilizes computer-based data acquisition sensors and a digital gram…

  3. Damage assessment for seismic response of recycled concrete filled steel tube columns

    Science.gov (United States)

    Huang, Yijie; Xiao, Jianzhuang; Shen, Luming

    2016-09-01

    A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST).

  4. Proposals for Calculation of Bucking Coefficient for Concrete-Filled Steel Tube Columns

    Science.gov (United States)

    Krishan, A. L.; Sagadatov, A. I.; Surovtsov, M. M.

    2017-11-01

    This paper demonstrates that the methodology currently standardized in Russia to factor in the flexibility of reinforced concrete components under extra-central compression produce results that satisfactorily match the experimental values; however, that only holds for the components with a flexibility of λ=40÷60. Given the complex stress state of the concrete core and the steel shell as well as due to the concrete-filled steel tube columns being prone to deformation, this method cannot be used to reliably calculate their load capacity. The literature review has revealed many researchers’ suggestions to factor in the flexibility of concrete-filled steel tubes by means of the buckling coefficient that reduces the limit value of longitudinal force a short compressed element can take. We have analyzed the methods currently standardized in Europe and China as well as more advanced methods proposed by Chinese scientists. Calculating by these methods led to the results that excessively deviated from experimental values. By statistically analyzing a large volume of own and third-party research data as well as the data obtained by non-linear deformation computing, we have derived a new formula to determine the bucking coefficient depending on the relative flexibility.

  5. Numerical study of confinement in short concrete filled steel tube columns

    Directory of Open Access Journals (Sweden)

    P.K. Gupta

    Full Text Available This study presents a numerical investigation into the behaviour of short concrete filled steel tubular (CFST columns. Three Dimensional Nonlinear finite element analysis of the compression process is performed using commercial software ABAQUS v6.9 (2009. Steel tubes of different geometries and in-filled with different grades of concrete are chosen for modelling from literature. The proposed FE model is validated by comparing its results with those of the corresponding experimental specimens. The model is further used to study the variation of radial confining pressure f cp provided by the steel tube to the concrete core. It is observed that the value of f cp varies widely throughout the length of the CFST, with the values in the area adjacent to top and bottom platens being markedly higher than the values in-between due to the end restraint provided by the machine platens. This is in contrast to the present confined concrete model which uses a uniform value of confining pressure throughout the height. Effect of effective length of column and interfacial friction present between the platen and specimen are found to be negligible on behaviour of short CFST column.

  6. Plastic collapse and energy absorption of circular filled tubes under quasi-static loads by computational analysis

    Energy Technology Data Exchange (ETDEWEB)

    Beng, Yeo Kiam; Tzeng, Woo Wen [Universiti Malaysia Sabah, Sabah (Malaysia)

    2017-02-15

    This study presents the finite element analysis of plastic collapse and energy absorption of polyurethane-filled aluminium circular tubes under quasi-static transverse loading. Increasing focuses were given to impact damage of structures where energy absorbed during impact could be controlled to avoid total structure collapse of energy absorbers and devices designed to dissipate energy. ABAQUS finite element analysis application was utilized for modelling and simulating the polyurethane-filled aluminium tubes, different set of diameterto- thickness ratios and span lengths, subjected to transverse three-point-bending load. Different sets of polyurethane-filled aluminium tubes subjected to the transverse loading were modelled and simulated. The failure modes and mechanisms of filled tubes and its capabilities as energy absorbers to further improve and strengthening of empty tube were also identified. The results showed that plastic deformation response was affected by the geometric constraints and parameters of the specimens. The diameter-to-thickness ratio and span lengths had shown to play crucial role in optimizing the PU-filled tube as energy absorber.

  7. Plastic collapse and energy absorption of circular filled tubes under quasi-static loads by computational analysis

    International Nuclear Information System (INIS)

    Beng, Yeo Kiam; Tzeng, Woo Wen

    2017-01-01

    This study presents the finite element analysis of plastic collapse and energy absorption of polyurethane-filled aluminium circular tubes under quasi-static transverse loading. Increasing focuses were given to impact damage of structures where energy absorbed during impact could be controlled to avoid total structure collapse of energy absorbers and devices designed to dissipate energy. ABAQUS finite element analysis application was utilized for modelling and simulating the polyurethane-filled aluminium tubes, different set of diameterto- thickness ratios and span lengths, subjected to transverse three-point-bending load. Different sets of polyurethane-filled aluminium tubes subjected to the transverse loading were modelled and simulated. The failure modes and mechanisms of filled tubes and its capabilities as energy absorbers to further improve and strengthening of empty tube were also identified. The results showed that plastic deformation response was affected by the geometric constraints and parameters of the specimens. The diameter-to-thickness ratio and span lengths had shown to play crucial role in optimizing the PU-filled tube as energy absorber

  8. Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube

    Directory of Open Access Journals (Sweden)

    Qiyun Qiao

    2017-08-01

    Full Text Available In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST, push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on the performance of CFSTs, which are the width to thickness ratio of steel tube, thickness of steel plate, length of steel plate, strength of concrete, welding condition of steel plate, number of steel plate layer and interlayer spacing. The test results show that the ultimate bearing capacity and the elastic stiffness increase with decreasing width to thickness ratio of the steel tube, and increasing thickness and length of the steel plate. With increasing concrete strength, the ultimate bearing capacity also increases. However, the welding condition has no effect on the ultimate bearing capacity. The ultimate bearing capacity of the CFST with double-layer steel plate is greater than that with single-layer steel plate. The ultimate bearing capacity of steel bar type shear connector is 87% greater than that of the steel plate type shear connector, and the steel bar specimen shows good ductility. A formula for calculating the shear-bearing capacity of shear connectors has been developed, and the calculated shear-bearing capacities are in good agreement with the test data.

  9. Experimental Study on Stress Monitoring of Sand-Filled Steel Tube during Impact Using Piezoceramic Smart Aggregates.

    Science.gov (United States)

    Du, Guofeng; Zhang, Juan; Zhang, Jicheng; Song, Gangbing

    2017-08-22

    The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structure under an impact is important for structural health monitoring. In this paper, piezoceramic Smart Aggregates (SAs) are embedded into a quartz Sand-Filled Steel Tube Column (SFSTC) to monitor the internal structural stress during impacts. The piezoceramic smart aggregates are first calibrated by an impact hammer. Tests are conducted to study the feasibility of monitoring the internal stress of a structure. The results reflect that the calibration value of the piezoceramic smart aggregate sensitivity test is in good agreement with the theoretical value, and the output voltage value of the piezoceramic smart aggregate has a good linear relationship with external forces. Impact tests are conducted on the sand-filled steel tube with embedded piezoceramic smart aggregates. By analyzing the output signal of the piezoceramic smart aggregates, the internal stress state of the structure can be obtained. Experimental results demonstrated that, under the action of impact loads, the piezoceramic smart aggregates monitor the compressive stress at different locations in the steel tube, which verifies the feasibility of using piezoceramic smart aggregate to monitor the internal stress of a structure.

  10. Experimental Study on Stress Monitoring of Sand-Filled Steel Tube during Impact Using Piezoceramic Smart Aggregates

    Directory of Open Access Journals (Sweden)

    Guofeng Du

    2017-08-01

    Full Text Available The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structure under an impact is important for structural health monitoring. In this paper, piezoceramic Smart Aggregates (SAs are embedded into a quartz Sand-Filled Steel Tube Column (SFSTC to monitor the internal structural stress during impacts. The piezoceramic smart aggregates are first calibrated by an impact hammer. Tests are conducted to study the feasibility of monitoring the internal stress of a structure. The results reflect that the calibration value of the piezoceramic smart aggregate sensitivity test is in good agreement with the theoretical value, and the output voltage value of the piezoceramic smart aggregate has a good linear relationship with external forces. Impact tests are conducted on the sand-filled steel tube with embedded piezoceramic smart aggregates. By analyzing the output signal of the piezoceramic smart aggregates, the internal stress state of the structure can be obtained. Experimental results demonstrated that, under the action of impact loads, the piezoceramic smart aggregates monitor the compressive stress at different locations in the steel tube, which verifies the feasibility of using piezoceramic smart aggregate to monitor the internal stress of a structure.

  11. Validation of the minimal citrate tube fill volume for routine coagulation tests on ACL TOP 500 CTS®.

    Science.gov (United States)

    Ver Elst, K; Vermeiren, S; Schouwers, S; Callebaut, V; Thomson, W; Weekx, S

    2013-12-01

    CLSI recommends a minimal citrate tube fill volume of 90%. A validation protocol with clinical and analytical components was set up to determine the tube fill threshold for international normalized ratio of prothrombin time (PT-INR), activated partial thromboplastin time (aPTT) and fibrinogen. Citrated coagulation samples from 16 healthy donors and eight patients receiving vitamin K antagonists (VKA) were evaluated. Eighty-nine tubes were filled to varying volumes of >50%. Coagulation tests were performed on ACL TOP 500 CTS(®) . Receiver Operating Characteristic (ROC) plot, with Total error (TE) and critical difference (CD) as possible acceptance criteria, was used to determine the fill threshold. Receiving Operating Characteristic was the most accurate with CD for PT-INR and TE for aPTT resulting in thresholds of 63% for PT and 80% for aPTT. By adapted ROC, based on threshold setting at a point of 100% sensitivity at a maximum specificity, CD was best for PT and TE for aPTT resulting in thresholds of 73% for PT and 90% for aPTT. For fibrinogen, the method was only valid with the TE criterion at a 63% fill volume. In our study, we validated the minimal citrate tube fill volumes of 73%, 90% and 63% for PT-INR, aPTT and fibrinogen, respectively. © 2013 John Wiley & Sons Ltd.

  12. Dynamic Measurements of Plastic Deformation in a Water-Filled Aluminum Tube in Response to Detonation of a Small Explosives Charge

    Directory of Open Access Journals (Sweden)

    Harold Sandusky

    1999-01-01

    Full Text Available Experiments have been conducted to benchmark computer code calculations for the dynamic interaction of explosions in water with structures. Aluminum cylinders with a length slightly more than twice their diameter were oriented vertically, sealed on the bottom by a thin plastic sheet, and filled with distilled water. An explosive charge suspended in the center of the tube plastically deformed but did not rupture the wall. Tube wall velocity, displacement, and strain were directly measured. The agreement among the three sets of dynamic data and the agreement of the terminal displacement measurements with the residual deformation were excellent.

  13. Development of Lateral Prestress in High-Strength Concrete-Filled FRP Tubes

    Science.gov (United States)

    Vincent, T.; Ozbakkaloglu, T.

    2018-02-01

    This paper reports on an experimental investigation into the axial and lateral strain development of fiber reinforced polymer (FRP) confined high-strength concrete (HSC) with prestressed FRP shells. A total of 24 aramid FRP (AFRP)-confined concrete specimens were manufactured as concrete-filled FRP tubes (CFFTs) with instrumentation to measure the strain variations during application of prestress, removal of end constraints and progressive prestress losses. Prestressed CFFT specimens were prepared with three different dose rates of expansive mineral admixture to create a range of lateral prestress applied to AFRP tubes manufactured with sheet thicknesses of 0.2 or 0.3 mm/ply and referred to as lightly- or well-confined, respectively. In addition to these three levels of prestress, non-prestressed companion specimens were manufactured and tested to determine baseline performance. The experimental results from this study indicate that lateral prestressing of CFFTs manufactured with HSC can be achieved by varying the expansive mineral admixture dose rate with a lateral prestress of up to 7.3 MPa recorded in this study. Significant strain variations were measured during removal of the end constraints with up to 700 microstrain recorded in the axial direction. Finally, the measurement of prestress losses for the month following prestress application revealed minimal progressive losses, with only 250 and 100 με recorded for the axial and hoop strains, respectively.

  14. Axial Crushing and Energy Absorption of Empty and Foam Filled Jute-glass/ Epoxy Bi-tubes

    Directory of Open Access Journals (Sweden)

    Khalid Asad A.

    2016-01-01

    Full Text Available Experimental work on the axial crushing of empty and polyurethane foam filled bi-tubular composite cone-tube has been carried out. Hand lay-up method was used to fabricate the bi-tubes using woven roving glass, jute and hybrid jute-glass/epoxy materials. The tubes were of 56 mm diameter, and the cones top diameters were 65 mm. Cone semi-apical angles of 5°, 10°, 15°, 20° and 25° were examined. Height of 120 mm was maintained for all the fabricated specimens. Effects of material used, cone semi apical angle and foam filler on the load-displacement relation, maximum load, crush force efficiency, and the specific energy absorption and failure mode were investigated. Results show that the foam filler improved the progressive crushing process, increased the maximum load and the absorbed energy of the bi-tubes. The maximum crushing load and the specific energy absorption increased with increasing the cone semi apical angle up to 20° for the empty bi-tubes and up to 25° for the foam filled bi-tubes. Progressive failure mode with fiber and matrix cracking was observed at the top narrow side of the fractured bi-tubes as well as at the bottom surface of 20° and 25° cone semi-apical angle bi-tubes.

  15. Gas-filled hohlraum experiments at the national ignition facility.

    Energy Technology Data Exchange (ETDEWEB)

    Fernández, J. C. (Juan C.); Gautier, D. C. (Donald Cort); Goldman, S. R. (Sanford R.); Grimm, B. M.; Hegelich, B. M. (Bjorn M.); Kline, J. L. (John L.); Montgomery, D. S. (David S.); Lanier, N. E. (Nicholas E.); Rose, H. A. (Harvey A.); Schmidt, D. M. (David M.); Swift, D. C.; Workman, J. B. (Jonathan B.); Alvarez, Sharon; Bower, Dan.; Braun, Dave.; Campbell, K. (Katherine); DeWald, E.; Glenzer, S. (Siegfried); Holder, J. (Joe P.); Kamperschroer, J. H. (James H.); Kimbrough, Joe (Joseph R.); Kirkwood, Robert (Bob); Landen, O. L. (Otto L.); Mccarville, Tom (Tomas J.); Macgowan, B.; Mackinnon, A.; Niemann, C.; Schein, J.; Schneider, M; Watts, Phil; Young, Ben-li [number : znumber] 194154; Young B.

    2004-01-01

    The summary of this paper is: (1) We have fielded on NIF a gas-filled hohlraum designed for future ignition experiments; (2) Wall-motion measurements are consistent with LASNEX simulations; (3) LPI back-scattering results have confounded expectations - (a) Stimulated Brillouin (SBS) dominates Raman (SRS) for any gas-fill species, (b) Measured SBS time-averaged reflectivity values are high, peak values are even higher, (c) SRS and SBS peak while laser-pulse is rising; and (4) Plasma conditions at the onset of high back-scattering yield high SBS convective linear gain - Wavelengths of the back-scattered light is predicted by linear theory.

  16. Strength of Short Concrete Filled Steel Tube Columns with Spiral Reinforcement

    Science.gov (United States)

    Krishan, A. L.; Troshkina, E. A.; Astafyeva, M. A.

    2017-11-01

    To further increase the bearing capacity and survivability of reinforced concrete filled steel tube (RCFT) columns, it is offered to supply their concrete core with additional spiral reinforcement. Such reinforcement also has a positive effect on the fire resistance of the columns. The practical use of compressed RCFT elements is restrained by the absence of procedures for determining their bearing capacity. A calculation procedure for determining the strength of short centrally compressed RCFT columns is offered. It is rather easy in terms of application and it allows one to take into account the main features of power resistance of such columns. The results of comparison of the calculated strength with experimental data are presented. The analysis of these results testifies that the accuracy of calculation of RCFT columns strength is sufficient for practice. The offered calculation procedure allows to provide the wider use of RCFT columns in construction practice as heavy loaded bearing elements of buildings and structures. It is recommended to use high-strength longitudinal reinforcement for further increase of the efficiency of these columns.

  17. Early Experience with the StopLoss Jones Tube.

    Science.gov (United States)

    Bagdonaite, Laura; Pearson, Andrew R

    2015-06-01

    Extrusion is the most common reason for failure after Jones tube placement. The StopLoss Jones tube (SLJT) is a new innovation in Jones tubes that incorporates a flexible silicone internal flange to resist extrusion. We present our early experience of using this new tube and associated introducer system. We retrospectively analysed the case notes of a single surgeon consecutive series of patients having SLJT placement from November 2011 to November 2013. 29 SLJTs were placed in 25 eyes of 19 patients. Tube follow-up ranged from 1-25 months (mean 10 months) with a total of 291 tube-months. The indications for SLJT placement were: previous LJT complications (52%), failed canalicular-DCR surgery (31%), primary placement for inoperable canalicular occlusion (14%) and patent non-functioning DCR (3%). Tube length ranged from 10-16 mm. The tube introducer system was simple and effective and there were no intra-operative complications. The tube extrusion rate was 0%. Complications occurred in 5 tubes: 1 was too long, and 4 others (14%) developed conjunctival overgrowth/medial tube migration. Patient satisfaction with the tube was: 86% fully satisfied, 10% was moderately satisfied, 3% not satisfied. The overall final surgical success rate at last follow-up was 92%. In this short follow-up initial study the SLJT is simple to use and has a high rate of success and patient satisfaction. The addition of the internal silicone flange appears to prevent the previously common problem of extrusion.

  18. Crush analysis of the foam-filled bitubal circular tube under oblique impact

    Science.gov (United States)

    Djamaluddin, F.; Abdullah, S.; Arrifin, A. K.; Nopiah, Z. M.

    2018-02-01

    This paper presents crashworthiness analysis of bitubal cylindrical tubes under different impact angular. The numerical solution of double cylindrical tubes are determined by finite element analysis (FEA). Moreover, the structure was impacted by mass block as impactor respect to longitudinal direction of the tubes. The model of structure was developed by non-linear ABAQUS sofware with variations of load angle and dimensions of tube. The outcome of this study is the respons parameters such as the peak crusing force (PCF), energy absorption (EA) and specific energy absorption (SEA), thus it can be expected this tube as the great energy absorber.

  19. Experimental analysis of energy absorption behaviour of Al-tube filled with pumice lightweight concrete under axial loading condition

    Science.gov (United States)

    Rajak, D. K.; Deshpande, P. G.; Kumaraswamidhas, L. A.

    2017-08-01

    This Paper aimed at experimental investigation of compressive behaviour of square tube filled with pumice lightweight concrete (PLC). Square section of 20×20×30 mm is investigated, which is the backbone structure. The compression deformation result shows the better folding mechanism, displacement value, and energy absorption. PLC concrete filled with aluminium thin-wall tubes has been revealed superior energy absorption capacity (EAC) under low strain rate at room temperature. Superior EAC resulted as a result of mutual deformation benefit between aluminium section and PLC is also analysed. PLC was characterised by Fourier Transform Infrared (FTIR) and Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Spectrometry (EDX) analysis for better understanding of material behaviour. Individual and comparative load bearing graphs is logged for better prospective of analysing. Novel approach aimed at validation of porous lightweight concrete for better lightweight EA filler material.

  20. Tensile Strength of Welded Steel Tubes : First Series of Experiments

    Science.gov (United States)

    Rechtlich, A

    1928-01-01

    The purpose of the experiments was to determine the difference in the strength of steel tubes welded by different methods, as compared with one another and also with unwelded, unannealed tubes, including; moreover, a comparison of the results obtained by experienced and inexperienced welders.

  1. A new model for analyzing nonlinear torsion behavior of concrete filled steel tube columns with rectangular section

    Science.gov (United States)

    Wang, Yuhang; Nie, Jianguo; Fan, Jiansheng

    2016-06-01

    An experimental study on concrete filled steel tube columns with rectangular section subjected to compressionflexure-torsion combined action has been carried out. The failure modes and load-deformation hysteretic relations were obtained. Based on the principles of classical material mechanics, the relations between the torsion curvature of the section and the shear strain of the fiber on the section were established. Then the strain distribution on the rectangular section of concrete filled steel tube columns subjected to torsion was analyzed. The three-dimensional refined finite element model was also built, in order to make the precision verification. The matrix forms of the relation between the torsion curvature of the section and the shear strain of the fiber on the section were derived, and introduced into the fiber beam model considering nonlinear torsion effect on the section. The comparison between test results and calculation results showed that the fiber beam model considering nonlinear torsion effect had high modeling efficiency and solution precision for predicting the torsion behavior of concrete filled steel tube columns with rectangular sections, and was suitable for analyzing the dynamic response of various structures subjected to the combined cyclic load caused by the earthquake load.

  2. Investigation of Mild Steel Thin-Wall Tubes in Unfilled and Foam-Filled Triangle, Square, and Hexagonal Cross Sections Under Compression Load

    Science.gov (United States)

    Rajak, Dipen Kumar; Kumaraswamidhas, L. A.; Das, S.

    2018-02-01

    This study has examined proposed structures with mild steel-reinforced LM30 aluminum (Al) alloy having diversely unfilled and 10 wt.% SiCp composite foam-filled tubes for improving axial compression performance. This class of material has novel physical, mechanical, and electrical properties along with low density. In the present experiment, Al alloy foams were prepared by the melt route technique using metal hydride powder as a foaming agent. Crash energy phenomena for diverse unfilled and foam-filled in mild steel thin-wall tubes (triangular, square and hexagonal) were studied as well. Compression deformation investigation was conducted at strain rates of 0.001-0.1/s for evaluating specific energy absorption (SEA) under axial loading conditions. The results were examined to measure plateau stress, maximum densification strain, and deformation mechanism of the materials. Specific energy absorption and total energy absorption capacities of the unfilled and filled sections were determined from the compressive stress-strain curves, which were then compared with each other.

  3. Inner tube growth and electronic properties of metallicity-sorted nickelocene-filled semiconducting single-walled carbon nanotubes

    Science.gov (United States)

    Kharlamova, M. V.; Kramberger, C.; Sauer, M.; Yanagi, K.; Saito, T.; Pichler, T.

    2018-03-01

    In the present work, we have obtained metallicity-sorted nickelocene-filled semiconducting single-walled carbon nanotubes (SWCNTs) by density gradient separation of metallicity mixed filled nanotubes. Double-walled carbon nanotubes (DWCNTs) were obtained by annealing of filled SWCNTs in vacuum. The diameter distribution of inner tubes was analyzed by multifrequency Raman spectroscopy. The chemical transformation of nickelocene upon annealing was studied by X-ray photoelectron spectroscopy (XPS) at the Ni 2 p core level. The thermally-induced transformation of nickelocene to nickel carbides and metallic nickel was revealed. The electronic properties of the filled SWCNTs and DWCNTs were investigated by XPS at the C 1 s core level. By tracing the C 1 s binding energy, it was shown that the annealing of nickelocene-filled SWCNTs at low temperatures (360-600 °C) led to electron doping of SWCNTs, whereas annealing at high temperatures and formation of DWCNTs (680-1200 °C) resulted in hole doping of nanotubes.

  4. Numerical heat transfer analysis of transcritical hydrocarbon fuel flow in a tube partially filled with porous media

    Science.gov (United States)

    Jiang, Yuguang; Feng, Yu; Zhang, Silong; Qin, Jiang; Bao, Wen

    2016-01-01

    Hydrocarbon fuel has been widely used in air-breathing scramjets and liquid rocket engines as coolant and propellant. However, possible heat transfer deterioration and threats from local high heat flux area in scramjet make heat transfer enhancement essential. In this work, 2-D steady numerical simulation was carried out to study different schemes of heat transfer enhancement based on a partially filled porous media in a tube. Both boundary and central layouts were analyzed and effects of gradient porous media were also compared. The results show that heat transfer in the transcritical area is enhanced at least 3 times with the current configuration compared to the clear tube. Besides, the proper use of gradient porous media also enhances the heat transfer compared to homogenous porous media, which could help to avoid possible over-temperature in the thermal protection.

  5. Bridge-in-a-backpack(TM) task 3.3 : investigate soil-structure interaction-modeling and experimental results of concrete filled FRP tube arches.

    Science.gov (United States)

    2015-12-01

    This report includes fulfillment of Task 3.3 of a multi-task contract to further enhance concrete filled FRP tubes, or : the Bridge in a Backpack. Task 3 is an investigation of soil-structure interaction for the FRP tubes. Task 3.3 is the : modeling ...

  6. Active interface debonding detection of a concrete-filled steel tube with piezoelectric technologies using wavelet packet analysis

    Science.gov (United States)

    Xu, Bin; Zhang, Ting; Song, Gangbing; Gu, Haichang

    2013-03-01

    Concrete-Filled Steel Tube (CFST) has been widely adopted in high-rise buildings and bridges as a typical structural member carrying vertical loads in recent years. The debonding between the steel tube and the concrete can dramatically reduce the confinement effect of steel tube on the concrete and decrease the load-carrying capacity and the ductility of the CFST. It is still challenging to develop reliable debonding monitoring and detection techniques for CFST because of the inaccessibility of the interface. In this study, an active interface condition monitoring approach for CFST by the use of lead zirconate titanate (PZT) piezoceramics based functional smart aggregates (SAs) embedded in concrete as actuator and PZT patches bonded on the surface of the steel tube as sensors is proposed and verified experimentally. Laboratory tests are performed on the CFST column, in which the deboning is mimicked by setting four thin styrofoam plates with different sizes on different locations of the four internal surfaces of the steel tube, respectively, before casting the concrete. The responses of the PZT sensors are measured when each SA is excited with sweep sinusoidal signals. According to the Fourier spectra and two evaluation indices based on the wavelet packet analysis on the PZT sensors measurements, the artificially mimicked debonding areas are detected successfully. Analysis on the sensitivity of the two evaluation indices shows that the indices based on wavelet packet analysis are more sensitive to the debonding defect. The proposed PZT based active debonding monitoring method provides an innovative approach to detect the debonding damage of CFST columns.

  7. Flow-induced decentering and tube support interaction for steam generator tubes: experiment and physical interpretation

    International Nuclear Information System (INIS)

    Gay, N.; Granger, S.

    1992-11-01

    Maintaining PWR components under reliable operating conditions requires a complex design to prevent various damaging processes including flow-induced vibration and wear mechanisms. To improve the prediction of tube/support interaction and wear in PWR components, EDF has undertaken a comprehensive program oriented to both experimental and computational studies. The present paper illustrates one aspect of this program, related to the determination of contact forces between steam generator tubes and anti-vibration bars (AVBs). The dynamic, nonlinear behavior of a U-tube excited by an air cross-flow is investigated on the CLAVECIN experiment. Interesting and rather unexpected results have been obtained, by varying clearances and flow velocities. The paper is focused on four main points: (i) the originality of the experiment with a force measurement device located in flow; (ii) the importance of a refined data processing for accurately measuring contact forces; (iii) the presentation of the unexpected phenomena revealed in the CLAVECIN experiment, i.e. a flow-induced decentering of the tube which changed the initial tube/AVB clearance, and the consequences on tube/support interaction; (iv) the influence of the actual tube/support clearance in flow on wear mechanisms. The work, presented in the second part of this paper, concentrates exclusively on the physical interpretation of the flow-induced decentering phenomenon and on the theoretical analysis of its consequences on dynamic tube/support interaction. We show that the flow-induced decentering phenomenon can be generated by an unstable quasi-static coupling between the flexible tube and the confined flow, in the vicinity of the support system. This phenomenon is not specific to the CLAVECIN tests and it can be expected every time that a movable obstacle is subjected to confined flow. Moreover, in single-sided impacting conditions, the theoretical analysis confirms the linear relation, found in the CLAVECIN tests

  8. Analysis of geosynthetic tubes filled with several liquids with different densities

    Czech Academy of Sciences Publication Activity Database

    Malík, Josef; Sysala, Stanislav

    2011-01-01

    Roč. 29, č. 3 (2011), s. 249-256 ISSN 0266-1144 R&D Projects: GA ČR GA103/08/1700 Institutional research plan: CEZ:AV0Z30860518 Keywords : geosyntetic tube * rigid horizontal foundation * numerical modelling Subject RIV: BA - General Mathematics Impact factor: 2.036, year: 2011 http://www.sciencedirect.com/science/article/pii/S0266114410001214

  9. Analysis of geosynthetic tubes filled with several liquids with different densities

    Czech Academy of Sciences Publication Activity Database

    Malík, Josef; Sysala, Stanislav

    2010-01-01

    Roč. 29, - (2010), s. 249-256 ISSN 0266-1144 R&D Projects: GA ČR GA103/08/1700 Institutional research plan: CEZ:AV0Z30860518 Keywords : geosyntetic tube * rigid horizontal foundation * numerical modelling Subject RIV: BA - General Mathematics Impact factor: 2.590, year: 2010 www.elsevier.com/locate/geotexmen, doi:10.1016/j.geotexmen.2010.11.004

  10. The gas system of the drift tube detector of the neutrino experiment OPERA

    Science.gov (United States)

    Ferber, T.; Bick, D.; Ebert, J.; Hagner, C.; Hierholzer, M.; Göllnitz, C.; Janutta, B.; Lenkeit, J.; Schmidt-Parzefall, W.; Wonsak, B.; Zimmermann, R.

    2008-07-01

    The gas system of the drift tube detector of the neutrino experiment OPERA is presented. The drift tube detector, called precision tracker (PT), consists of 10 000 thinwalled aluminum tubes of 38 mm diameter and 8 m length filled with an 80% Ar 20% CO2 gas mixture. The total gas volume amounts to 80 m3. During stable operation the gas is exchanged once per 80 h and not recycled. Thus about 1 m 3 per hour is consumed. Argon and CO2 are stored and supplied in liquid form. Subsequently they are mixed and the composition ratio is regulated with a precision better than 1% per component. Inside the drift tubes the gas is kept at a constant absolute pressure within ±0.5%. Since the experiment is operated in the low activity environment of the Gran Sasso underground laboratory, monitoring of the gas quality with a radioactive source is prohibited. Instead the oxygen content of the used gas is measured. We report on the first experience with the performance of the gas system.

  11. Planet in a Test Tube Experiment

    Science.gov (United States)

    1985-01-01

    A 16mm film frame shows convective regions inside silicone oil playing the part of a stellar atmosphere in the Geophysical Fluid Flow Cell (GFFC). An electrostatic field pulled the oil inward to mimic gravity's effects during the experiments. The GFFC thus produced flow patterns that simulated conditions inside the atmospheres of Jupiter and the Sun and other stars. Numbers of the frame indicate temperatures and other conditions. This image is from the Spacelab-3 flight in 1985. GFFC was reflown on U.S. Microgravity Laboratory-2 in 1995. The principal investigator was John Hart of the University of Colorado at Boulder. It was managed by NASA's Marshall Space Flight Center. (Credit: NASA/Marshall Space Flight Center)

  12. Analysis of the Falcon thermal-gradient tube experiments

    International Nuclear Information System (INIS)

    Chown, N.M.; Williams, D.A.

    1990-12-01

    The work described in this report was performed in support of the Falcon experimental programme, and was part-funded by the CEC and HSE. The analyses of some of the earlier Falcon thermal-gradient tube experiments, namely tests TG-1, TG-2, TG-3, TG-6 and TG-7, using the VICTORIA computer code are discussed. In each test an induction furnace was used to heat a simulant or trace-irradiated LWR fuel and/or control rod sample. The resulting fission product vapours and aerosols were transported at high temperatures through a thermal-gradient tube system, and their deposition behaviour and chemical activities were measured. (author)

  13. Optimal Design of Shock Tube Experiments for Parameter Inference

    KAUST Repository

    Bisetti, Fabrizio

    2014-01-06

    We develop a Bayesian framework for the optimal experimental design of the shock tube experiments which are being carried out at the KAUST Clean Combustion Research Center. The unknown parameters are the pre-exponential parameters and the activation energies in the reaction rate expressions. The control parameters are the initial mixture composition and the temperature. The approach is based on first building a polynomial based surrogate model for the observables relevant to the shock tube experiments. Based on these surrogates, a novel MAP based approach is used to estimate the expected information gain in the proposed experiments, and to select the best experimental set-ups yielding the optimal expected information gains. The validity of the approach is tested using synthetic data generated by sampling the PC surrogate. We finally outline a methodology for validation using actual laboratory experiments, and extending experimental design methodology to the cases where the control parameters are noisy.

  14. Thirty-five years of drift-tube linac experience

    International Nuclear Information System (INIS)

    Knowles, H.B.

    1984-10-01

    The history of the drift-tube linear accelerator (linac) for the first 35 years of its existence is briefly reviewed. Both US and foreign experience is included. Particular attention is given to technological improvements, operational reliability, capital investment, and number of personnel committed to drift-tube linac (DTL) development. Preliminary data indicate that second- and third-generation (post-1960) DTLs have, in the US alone, operated for a combined total period of more than 75 machine-years and that very high reliability (>90%) has been achieved. Existing US drift-tube linacs represent a capital investment of at least $250 million (1983). Additional statistical evidence, derived from the proceedings of the last 11 linear accelerator conferences, supports the view that the DTL has achieved a mature technological base. The report concludes with a discussion of important recent advances in technology and their applications to the fourth generation of DTLs, many of which are now becoming operational

  15. Biaxial bending of slender HSC columns and tubes filled with concrete under short- and long-term loads: I Theory

    Directory of Open Access Journals (Sweden)

    Jose A. Rodríguez-Gutiérrez

    2014-05-01

    Full Text Available An analytical method that calculates both the short- and long-term response of slender columns made of high-strength concrete (HSC and tubes filled with concrete with generalized end conditions and subjected to transverse loads along the span and axial load at the ends (causing a single or double curvature under uniaxial or biaxial bending is presented. The proposed method, which is an extension of a method previously developed by the authors, is capable of predicting not only the complete load-rotation and load-deflection curves (both the ascending and descending parts but also the maximum load capacity. The columns that can be analyzed include solid and hollow (rectangular, circular, oval, C-, T-, L-, or any arbitrary shape cross sections and columns made of circular and rectangular steel tubes filled with HSC. The fiber method is used to calculate the moment-curvature diagrams at different levels of the applied axial load (i.e., the M-P-φ curves, and the Gauss method of integration (for the sum of the contributions of the fibers parallel to the neutral axis is used to calculate the lateral rotations and deflections along the column span. Long-term effects, such as creep and shrinkage of the concrete, are also included. However, the effects of the shear deformations and torsion along the member are not included. The validity of the proposed method is presented in a companion paper and compared against the experimental results for over seventy column specimens reported in the technical literature by different researchers.

  16. STUDI PERBANDINGAN PERILAKU DAN KINERJA STRUKTUR BAJA MENGGUNAKAN KOLOM KOMPOSIT CONCRETE ENCASED DAN CONCRETE FILLED TUBE, SERTA NON KOMPOSIT

    Directory of Open Access Journals (Sweden)

    I Ketut Diartama Kubon Tubuh

    2017-07-01

    Full Text Available Comparative study of steel structure behavior and performance using composite and non composite columns were done by making five structure models. A model using wide flange steel columns, two models with circular and square concrete encased columns (MCEC and MCES, also two models with circular and square concrete filled tube columns (MCFTC and MCFTS. Columns on 4th-5th floor are smaller than columns on three floors below. Structure behavior were observed through elastic analysis which are displacement and interstory drift. While structure performance were evaluated through non linear static Pushover analysis using SAP2000®. The analysis showed that with P-M ratio ranging from 0.79 until 0.88, all models interstory drifts were exceed limit on 1st, 2nd and 4th floors. Countermeasures were done by rotating half of total MS steel columns (then became MS-R, enlarging 4th-5th floor columns on MS-R and MCFTC, and also installing eight X-bracings on all models ground floor. Pushover analysis showed that performance level of all models are Immediate Occupancy (IO except MCFTS. MCFTS model which in Collapse (C performance level were improved by increasing thickness of steel section (then became MCFTS-Improved and resulting IO performance level. Calculation of structure materials cost showed the most expensive until the cheapest models respectively were MS-R, MCFTS-Improved, MCEC, MCES, and MCFTC with comparison 1:0,99:0,88:0,87:0,86.  Keywords: concrete encased (CE, concrete filled tube (CFT, X-bracing, Pushover analysis

  17. A New Tube Gastrostomy Model in Animal Experiments

    Directory of Open Access Journals (Sweden)

    Atakan Sezer

    2013-01-01

    Full Text Available Aim: The orogastric route is the most preferred application method in the vast majority of the animal experiments in which application can be achieved by adding the material to the water of the experiment animal, through an orogastric tube or with a surgically managed ostomy. Material and Method: This experiment was constructed with twelve male Sprague-Dawley rats which were randomly assigned to one of two groups consist of control group ( group C, n: 6 and tube gastrostomy group ( group TG, n: 6.A novel and simple gastrostomy tube was derivated from a silicone foley catheter. Tube gastrostomy apparatus was constituted with a silicone foley catheter (6 French. In the group TG an incision was performed, and the stomach was visualized. A 1 cm incision was made in the midline and opening of the peritoneum. Anchoring sutures were placed and anterior gastric wall was lifted. The gastric wall is then opened. The apparatus was placed into the stomach and pulled through from a tunnel under the skin and fixed to the lateral abdominal wall with a 2/0 silk suture. Result: The procedure was ended in the 10th day of experiment. No mortality was observed in group C. The rats were monitored daily and no abnormal behavior consists of self harming incision site, resistance to oral intake or attending to displace. There was statistically significant difference in increasing alanine transaminase level (p<0.05 and decrease in the total protein and body weight (p<0.05 at the group TG at the end of experiment. There was significant increase in urea levels in Group C (p<0.05 at the end of experiment. The statistically significant decrease was observed in the same period in group C between aspartate transaminase, albumin, total protein, and body weight (p<0.05.  Glucose (p=0.047 and aspartate transaminase (p=0.050 level decrease changes and weight loose (p=0.034 from preoperative period to the end of the experiment between gastrostomy and laparotomy groups were

  18. Three-in-One Resonance Tube for Harmonic Series Sound Wave Experiments

    Science.gov (United States)

    Jaafar, Rosly; Nazihah Mat Daud, Anis; Ali, Shaharudin; Kadri Ayop, Shahrul

    2017-01-01

    In this study we constructed a special three-in-one resonance tube for a harmonic series sound waves experiment. It is designed for three different experiments: both-open-end, one-closed-end and both-closed-end tubes. The resonance tube consists of a PVC conduit with a rectangular hole, rubber tube, plastic stopper with an embedded microphone and…

  19. Simultaneous Modeling of Waveforms Associated With Backscattered He-Ne Laser Light from a Fluid Filled Capillary Tube by Use of Geometrical Optics and Wave Theories

    International Nuclear Information System (INIS)

    Tarigan, Hendra J.

    2008-01-01

    Backscattered He-Ne laser light from a side illuminated fluid-filled fused silica capillary tube generates a series of fringes when viewed in an imaging plane. The light intensity variation as a function of scattering angle constitutes a waveform, which contains hills and valleys. Geometrical Optics and Wave Theories, simultaneously, are employed to model the waveforms and quantify the index of refraction of fluid in the capillary tube.

  20. Effect of viscosity on the wave propagation: Experimental determination of compression and expansion pulse wave velocity in fluid-fill elastic tube.

    Science.gov (United States)

    Stojadinović, Bojana; Tenne, Tamar; Zikich, Dragoslav; Rajković, Nemanja; Milošević, Nebojša; Lazović, Biljana; Žikić, Dejan

    2015-11-26

    The velocity by which the disturbance travels through the medium is the wave velocity. Pulse wave velocity is one of the main parameters in hemodynamics. The study of wave propagation through the fluid-fill elastic tube is of great importance for the proper biophysical understanding of the nature of blood flow through of cardiovascular system. The effect of viscosity on the pulse wave velocity is generally ignored. In this paper we present the results of experimental measurements of pulse wave velocity (PWV) of compression and expansion waves in elastic tube. The solutions with different density and viscosity were used in the experiment. Biophysical model of the circulatory flow is designed to perform measurements. Experimental results show that the PWV of the expansion waves is higher than the compression waves during the same experimental conditions. It was found that the change in viscosity causes a change of PWV for both waves. We found a relationship between PWV, fluid density and viscosity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. The Straw Tube Trackers of the PANDA Experiment

    International Nuclear Information System (INIS)

    Gianotti, P.; Lucherini, V.; Pace, E.; Boca, G.L.; Costanza, S.; Genova, P.; Lavezzi, L.; Montanga, P.; Rotondi, A.; Bragadireanu, M.; Vasile, M.E.; Pietreanu, D.; Biernat, J.; Jowzaee, S.; Korcyl, G.; Palka, M.; Salabura, P.; Smyrski, J.; Fiutowski, T.; Idzik, M.; Przyborowski, D.; Korcyl, K.; Kulessa, P.; Pysz, K.; Dobbs, S.; Tomaradze, A.; Bettoni, D.; Fioravanti, E.; Garzia, I.; Savrie, M.; Kozlov, V.; Mertens, M.; Ohm, H.; Orfanitski, S.; Ritman, J.; Serdyuk, V.; Wintz, P.; Spataro, S.

    2013-06-01

    The PANDA experiment will be built at the FAIR facility at Darmstadt (Germany) to perform accurate tests of the strong interaction through p-bar p and p-bar A annihilation's studies. To track charged particles, two systems consisting of a set of planar, closed-packed, self-supporting straw tube layers are under construction. The PANDA straw tubes will have also unique characteristics in term of material budget and performance. They consist of very thin mylar-aluminized cathodes which are made self-supporting by means of the operation gas-mixture over-pressure. This solution allows to reduce at maximum the weight of the mechanical support frame and hence the detector material budget. The PANDA straw tube central tracker will not only reconstruct charged particle trajectories, but also will help in low momentum (< 1 GeV) particle identification via dE/dx measurements. This is a quite new approach that PANDA tracking group has first tested with detailed Monte Carlo simulations, and then with experimental tests of detector prototypes. This paper addresses the design issues of the PANDA straw tube trackers and the performance obtained in prototype tests. (authors)

  2. PZT-Based Detection of Compactness of Concrete in Concrete Filled Steel Tube Using Time Reversal Method

    Directory of Open Access Journals (Sweden)

    Shi Yan

    2014-01-01

    Full Text Available A smart aggregate-based approach is proposed for the concrete compactness detection of concrete filled steel tube (CFST columns. The piezoceramic-based smart aggregates (SAs were embedded in the predetermined locations prior to the casting of concrete columns to establish a wave-based smart sensing system for the concrete compactness detection purpose. To evaluate the efficiency of the developed approach, six specimens of the CFST columns with the rectangular cross-section were produced by placing some artificial defects during casting of concrete for simulating various uncompacted voids such as cavities, cracks, and debond. During the test, the time reversal technology was applied to rebuild the received signals and launch the reversed signals again by SAs, to overcome the issue of the lack of the prototype. Based on the proposed nonprototype, two indices of time reversibility (TR and symmetry (SYM were applied to relatively evaluate the level of concrete compactness in the range of the two SAs. The experimental results show that the developed method can effectively detect the compactness of concrete in CFST columns.

  3. User Experience Evaluation in BCI: Filling the Gap

    NARCIS (Netherlands)

    Gürkök, Hayrettin; Plass - Oude Bos, D.; van de Laar, B.L.A.; Nijboer, Femke; Nijholt, Antinus

    2011-01-01

    Brain-computer interface (BCI) systems can improve the user experience (UX) when used in entertainment technologies. Improved UX can enhance user acceptance, improve quality of life and also increase the system performance of a BCI system. Therefore, the evaluation of UX is essential in BCI

  4. Experiences with the Montgomery Salivary Bypass Tube (MSBT)

    Science.gov (United States)

    Lörken, A; Krampert, J; Kau, R J; Arnold, W

    1997-01-01

    Patients with hypopharyngeal and cervical esophageal strictures and fistulas caused by advanced malignancy, ingestion of caustic material, or following surgery or radiation therapy often suffer from marked dysphagia. In such cases the implantation of a Montgomery Salivary Bypass Tube (MSBT) can be an effective therapeutic option to bridge the fistulous tract or bypass a stenosis. Being able to eat and drink without the need for intravenous supplementation or nasogastric or gastrostomy tube feeding in general greatly improves the patient's quality of life. Since 1981 we have successfully inserted the MSBT in 44 cases suffering from dysphagia of different etiology. Our experiences with the indications for implantation, insertion techniques, and postoperative results are presented. Three selected cases of progressive dysphagia in which the MSBT is demonstrated to be the treatment of choice are described in more detail. In one case, a tracheoesophageal fistula and in another a stricture of the upper esophageal sphincter (UES) were bypassed so that oral intake of soft food became possible again. The third patient suffered from a disturbance of the esophageal motility after resection of a Hippel-Lindau tumor in the spinal cord and syringe drainage; even swallowing saliva was impeded. After insertion of a MSBT, uncomplicated soft food intake became possible again.

  5. Modeling the progressive axial crushing of foam-filled aluminum tubes using smooth particle hydrodynamics and coupled finite element model/smooth particle hydrodynamics

    OpenAIRE

    Aktay, Levent; Johnson, Alastair F.; Toksoy, Ahmet Kaan; Kröplin, Bernd Helmut; Güden, Mustafa

    2008-01-01

    As alternatives to the classical finite element model (FEM), a meshless smooth particle hydrodynamics (SPH) method, in which the discrete particles represent a solid domain, and a coupled FEM/SPH modeling technique were investigated for the numerical simulation of the quasi-static axial crushing of polystyrene foam-filled aluminum thin-walled aluminum tubes. The results of numerical simulations, load-deformation histories, fold lengths and specific absorbed energies, were found to show satisf...

  6. The experiments of resonance tube method and resonator method ...

    Indian Academy of Sciences (India)

    Take a 50 ml measuring cylinder or a big test tube and hold it vertical using a stand. Add some water in the tube so that the horizontal surface of water is above the rounded bottom. Stick a strip of graph paper or ruler on the tube and mark a horizontal line corresponding to the water level. Keep the speaker pointing towards.

  7. What Is the Participant Learning Experience Like Using YouTube to Study a Foreign Language?

    Science.gov (United States)

    Lo, Yuan-Hsiang

    2012-01-01

    This research is to explore and understand participants' experience using YouTube to learn a foreign language. YouTube and learning has become more and more popular in the recent years. The finding of this research will be adding more understanding to the emerging body of knowledge of YouTube phenomenon. In this research, there are three…

  8. Three-in-one resonance tube for harmonic series sound wave experiments

    Science.gov (United States)

    Jaafar, Rosly; Nazihah Mat Daud, Anis; Ali, Shaharudin; Kadri Ayop, Shahrul

    2017-07-01

    In this study we constructed a special three-in-one resonance tube for a harmonic series sound waves experiment. It is designed for three different experiments: both-open-end, one-closed-end and both-closed-end tubes. The resonance tube consists of a PVC conduit with a rectangular hole, rubber tube, plastic stopper with an embedded microphone and a plastic stopper. The resonance tube is utilized with visual analyser freeware to detect, display and measure the resonance frequencies for each harmonic series. The speeds of sound in air, v, are determined from the gradient of the 2(L+e) versus n fn-1 , 4(L+e) versus n fn-1 and 2L versus n fn-1 graphs for both-open-end, one-closed-end and both-closed-end tubes, respectively. The compatibility of a resonance tube for a harmonic series experiment is determined by comparing the experimental and standard values of v. The use of a resonance tube produces accurate results for v within a 1.91% error compared to its standard value. It can also be used to determine the values of end correction, e, in both-open-end and one-closed-end tubes. The special resonance tube can also be used for the values of n for a harmonic series experiment in the three types of resonance tubes: both-open-end, one-closed-end and both-closed-end tubes.

  9. Design of experiments and equipment to test the ballooning characteristics of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Forrest, C.F.; Stern, F.; Hart, R.G.

    1992-01-01

    Experiments have been planned and an apparatus has been designed to enable creep testing of end-of-life pressure tube specimens in a LOCA environment. Effects that could be studied include: annealing of irradiation damage during transient heating; effects of hydride blisters on pressure tube ballooning strains; and, effects of uniformly-distributed hydrogen content on pressure tube ballooning strains. The proposed experimental program will consist of separate effects creep tests on pressure tube sections under transient heating conditions

  10. Investigation on the fiber based approach to estimate the axial load carrying capacity of the circular concrete filled steel tube (CFST)

    Science.gov (United States)

    Piscesa, B.; Attard, M. M.; Suprobo, P.; Samani, A. K.

    2017-11-01

    External confining devices are often used to enhance the strength and ductility of reinforced concrete columns. Among the available external confining devices, steel tube is one of the most widely used in construction. However, steel tube has some drawbacks such as local buckling which needs to be considered when estimating the axial load carrying capacity of the concrete-filled-steel-tube (CFST) column. To tackle this problem in design, Eurocode 4 provided guidelines to estimate the effective yield strength of the steel tube material. To study the behavior of CFST column, in this paper, a non-linear analysis using a fiber-based approach was conducted. The use of the fiber-based approach allows the engineers to predict not only the axial load carrying capacity but also the complete load-deformation curve of the CFST columns for a known confining pressure. In the proposed fiber-based approach, an inverse analysis is used to estimate the constant confining pressure similar to design-oriented models. This paper also presents comparisons between the fiber-based approach model with the experimental results and the 3D non-linear finite element analysis.

  11. Quantitative experiments on thermal hydraulic characteristics of an annular tube with twisted fins

    International Nuclear Information System (INIS)

    Ezato, Koichiro; Dairaku, Masayuki; Taniguchi, Masaki; Sato, Kazuyoshi; Suzuki, Satoshi; Akiba, Masato

    2003-11-01

    Thermal hydraulic experiments measuring critical heat flux (CHF) and pressure drop of an annular tube with twisted fins, ''annular swirl tube'', has been performed to examine its applicability to the ITER divertor cooling structure. The annular swirl tube consists of two concentric circular tubes, the outer and inner tubes. The outer tube with outer and inner diameters (OD and ID) of 21 mm and 15 mm is made of Cu-alloy that is CuCrZr and oe of candidate materials of the ITER divertor cooling tube. The inner tube with OD of 11 mm and ID of 9 mm is made of stainless steal. It has an external swirl fin with twist ratio (y) of three to enhance its heat transfer performance. In this tube, cooling water flows inside of the inner tube first, and then returns into an annulus between the outer and inner tubes with a swirl flow at an end-return of the cooling tube. The CHF experiments show that no degradation of CHF of the annular swirl tube in comparison with the conventional swirl tube whose dimensions are similar to those of the outer tube of the annular swirl tube. A minimum axial velocity of 7.1 m/s is required to remove the incident heat flux of 28MW/m 2 , the ITER design value. Applicability of the JAERI's correlation for the heat transfer to the annular swirl tube is also demonstrated by comparing the experimental results with those of the numerical analysis. The friction factor correlation for the annular flow with the twisted fins is also proposed for the hydrodynamic design of the ITER vertical target. The least pressure drop at the end-return is obtained by using the hemispherical end-plug. Its radius is the same as that of ID of the outer cooling tube. These results show that thermal-hydraulic performance of the annular swirl tube is promising in application to the cooling structure for the ITER vertical target. (author)

  12. Study on Axial Compressive Capacity of FRP-Confined Concrete-Filled Steel Tubes and Its Comparisons with Other Composite Structural Systems

    Directory of Open Access Journals (Sweden)

    Jun Deng

    2017-01-01

    Full Text Available Concrete-filled steel tubular (CFST columns have been widely used for constructions in recent decades because of their high axial strength. In CFSTs, however, steel tubes are susceptible to degradation due to corrosion, which results in the decrease of axial strength of CFSTs. To further improve the axial strength of CFST columns, carbon fiber reinforced polymer (CFRP sheets and basalt fiber reinforced polymer (BFRP sheets are applied to warp the CFSTs. This paper presents an experimental study on the axial compressive capacity of CFRP-confined CFSTs and BFRP-confined CFSTs, which verified the analytical model with considering the effect of concrete self-stressing. CFSTs wrapped with FRP exhibited a higher ductile behavior. Wrapping with CFRP and BFRP improves the axial compressive capacity of CFSTs by 61.4% and 17.7%, respectively. Compared with the previous composite structural systems of concrete-filled FRP tubes (CFFTs and double-skin tubular columns (DSTCs, FRP-confined CFSTs were convenient in reinforcing existing structures because of softness of the FRP sheets. Moreover, axial compressive capacity of CFSTs wrapped with CFRP sheets was higher than CFFTs and DSTCs, while the compressive strength of DSTCs was higher than the retrofitted CFSTs.

  13. Considerations for Explosively Driven Conical Shock Tube Design: Computations and Experiments

    Science.gov (United States)

    2017-02-16

    interest have been listed elsewhere (e.g., Courtney et al. 2012), but a limited list of advantages and disadvantages for explosively driven shock...ARL-TR-7953 ● FEB 2017 US Army Research Laboratory Considerations for Explosively Driven Conical Shock Tube Design: Computations ...Considerations for Explosively Driven Conical Shock Tube Designs: Computations and Experiments by Joel B Stewart Weapons and Materials Research Directorate

  14. A Simple Experiment to Explore Standing Waves in a Flexible Corrugated Sound Tube

    Science.gov (United States)

    Amorim, Maria Eva; Sousa, Teresa Delmira; Carvalho, P. Simeao; Sousa, Adriano Sampaioe

    2011-01-01

    Sound tubes, pipes, and singing rods are used as musical instruments and as toys to perform amusing experiments. In particular, corrugated tubes present unique characteristics with respect to the sounds they can produce; that is why they have been studied so intensively, both at theoretical and experimental levels. Experimental studies usually…

  15. Some Research Experiences in Microwave Tubes 1946 to 1961; From the TWT to the First Laser

    International Nuclear Information System (INIS)

    Birdsall, Charles K.

    2003-01-01

    The period 1946-1961 was a special era for microwave tubes, just after WWII, up until invention of the laser. Low noise, broadband, high power, high efficiency, from 60 MHz to 300 GHz, all done without modern computers (IC's invented in 1959). The major universities and industrial research labs all had active microwave tube research, which was well supported. Beam type tubes of all kinds were invented and experimented with. The Pierce analytic approach became the norm for linear analysis. Time from conception to experiment was short from new guns to new circuits. This paper is one person's experience at three universities and two industrial firms. Challenging, productive and rewarding

  16. Experience In The Management Of Neural Tube Defects At The ...

    African Journals Online (AJOL)

    Between January 1986 and December 1997, 97 cases of neural tube defects were seen at the University of Maiduguri Teaching Hospital (UMTH) Maiduguri. Male to female (M:F) ratio of 1.4:1 was observed with the commonest location of lesion being at the lumbo-sacral region. Majority of the patients came from rural ...

  17. One lung ventilation using double‑lumen tubes: Initial experience ...

    African Journals Online (AJOL)

    2014-05-09

    May 9, 2014 ... Background: One lung ventilation (OLV) is a technique routinely used in thoracic anesthesia to facilitate thoracic surgery. Double‑lumen tubes (DLT) remain the most popular and reliable choice for one lung ventilation especially in adult patients though use in Nigeria is limited. This study aimed to describe ...

  18. R & D of a Gas-Filled RF Beam Profile Monitor for Intense Neutrino Beam Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yonehara, K. [Fermilab; Backfish, M. [Fermilab; Moretti, A. [Fermilab; Tollestrup, A. V. [Fermilab; Watts, A. [Fermilab; Zwaska, R. M. [Fermilab; Abrams, R. [MUONS Inc., Batavia; Cummings, M. A.; Dudas, A. [MUONS Inc., Batavia; Johnson, R. P. [MUONS Inc., Batavia; Kazakevich, G. [MUONS Inc., Batavia; Neubauer, M. [MUONS Inc., Batavia; Liu, Q. [Case Western Reserve U.

    2017-05-01

    We report the R&D of a novel radiation-robust hadron beam profile monitor based on a gas-filled RF cavity for intense neutrino beam experiments. An equivalent RF circuit model was made and simulated to optimize the RF parameter in a wide beam intensity range. As a result, the maximum acceptable beam intensity in the monitor is significantly increased by using a low-quality factor RF cavity. The plan for the demonstration test is set up to prepare for future neutrino beam experiments.

  19. Production and test of monitored drift tubes for the muon spectrometer of the ATLAS experiment

    CERN Document Server

    Aprile, A; Campagna, A; Capua, M; Cuce, D; Ferraro, E; Lamanna, E; La Rotonda, L; Meoni, E; Pellegrino, F; Romano, V; Schioppa, M; Susinno, G; Turco, R P; Vena, R

    2002-01-01

    ATLAS is one of the two general-purpose experiments being built for the Large Hadron Collider at CERN. Its muon spectrometer consists of very high-precision chambers made of drift tubes. Up to now, more than 5000 monitored drift tubes (MDTs) have been constructed and tested at the University of Calabria, Italy, for ATLAS barrel system chambers of the muon detector. This paper reports the critical MDT assembly techniques in detail, including the automatic electronics system and data acquisition system. The extensive tests performed on individual drift tubes and the first results and experience are also reported. (5 refs).

  20. Results of molten salt panel and component experiments for solar central receivers: Cold fill, freeze/thaw, thermal cycling and shock, and instrumentation tests

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, J.E.; Ralph, M.E.; Chavez, J.M.; Dunkin, S.R.; Rush, E.E.; Ghanbari, C.M.; Matthews, M.W.

    1995-01-01

    Experiments have been conducted with a molten salt loop at Sandia National Laboratories in Albuquerque, NM to resolve issues associated with the operation of the 10MW{sub e} Solar Two Central Receiver Power Plant located near Barstow, CA. The salt loop contained two receiver panels, components such as flanges and a check valve, vortex shedding and ultrasonic flow meters, and an impedance pressure transducer. Tests were conducted on procedures for filling and thawing a panel, and assessing components and instrumentation in a molten salt environment. Four categories of experiments were conducted: (1) cold filling procedures, (2) freeze/thaw procedures, (3) component tests, and (4) instrumentation tests. Cold-panel and -piping fill experiments are described, in which the panels and piping were preheated to temperatures below the salt freezing point prior to initiating flow, to determine the feasibility of cold filling the receiver and piping. The transient thermal response was measured, and heat transfer coefficients and transient stresses were calculated from the data. Freeze/thaw experiments were conducted with the panels, in which the salt was intentionally allowed to freeze in the receiver tubes, then thawed with heliostat beams. Slow thermal cycling tests were conducted to measure both how well various designs of flanges (e.g., tapered flanges or clamp type flanges) hold a seal under thermal conditions typical of nightly shut down, and the practicality of using these flanges on high maintenance components. In addition, the flanges were thermally shocked to simulate cold starting the system. Instrumentation such as vortex shedding and ultrasonic flow meters were tested alongside each other, and compared with flow measurements from calibration tanks in the flow loop.

  1. Experiment attributes to establish tube with twisted tape insert performance cooling plasma facing components

    International Nuclear Information System (INIS)

    Clark, Emily; Ramirez, Emilio; Ruggles, Art E.; Griffard, Cory

    2015-01-01

    The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. As a result, the gaps in knowledge required to establish performance limits of the plasma facing components are identified and attributes of an experiment to close those gaps are presented

  2. Prediction of the surface roughness of AA6082 flow-formed tubes by design of experiments

    International Nuclear Information System (INIS)

    Srinivasulu, M.; Komaraiah, M.; Rao, C. S. Krishna Prasada

    2013-01-01

    Flow forming is a modern, chipless metal forming process that is employed for the production of thin-walled seamless tubes. Experiments are conducted on AA6082 alloy pre-forms to flow form into thin-walled tubes on a CNC flow-forming machine with a single roller. Design of experiments is used to predict the surface roughness of flow-formed tubes. The process parameters selected for this study are the roller axial feed, mandrel speed, and roller radius. A standard response surface methodology (RSM) called the Box Behnken design is used to perform the experimental runs. The regression model developed by RSM successfully predicts the surface roughness of AA6082 flow-formed tubes within the range of the selected process parameters.

  3. Prediction of the surface roughness of AA6082 flow-formed tubes by design of experiments

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasulu, M. [Government Polytechnic for Women Badangpet, Hyderabad (India); Komaraiah, M. [Sreenidhi Institute of Science and Technology, Hyderabad (India); Rao, C. S. Krishna Prasada [Bharat Dynamics Limited, Hyderabad (India)

    2013-06-15

    Flow forming is a modern, chipless metal forming process that is employed for the production of thin-walled seamless tubes. Experiments are conducted on AA6082 alloy pre-forms to flow form into thin-walled tubes on a CNC flow-forming machine with a single roller. Design of experiments is used to predict the surface roughness of flow-formed tubes. The process parameters selected for this study are the roller axial feed, mandrel speed, and roller radius. A standard response surface methodology (RSM) called the Box Behnken design is used to perform the experimental runs. The regression model developed by RSM successfully predicts the surface roughness of AA6082 flow-formed tubes within the range of the selected process parameters.

  4. Relating Molar Incisor Hypomineralization and Caries Experience Using the Decayed, Missing, or Filled Index.

    Science.gov (United States)

    Americano, Gabriela C A; Jorge, Roberta C; Moliterno, Luiz Flávio; Soviero, Vera M

    2016-10-15

    This case-control study aimed to investigate the association between molar incisor hypomineralization (MIH) and caries experience in seven- to 11-year-old children. Children seen in a pediatric dental clinic in 2011 to 2012 and born in 2002, 2003, or 2004 were considered eligible. Children with decayed, missing, or filled teeth in the permanent dentition (DMF-T) were allocated to the case group, and those with no DMF-T were allocated to the control group. An examiner assessed MIH according to European Academy of Pediatric Dentistry criteria and caries according to World Health Organization criteria. The odds ratio was calculated to evaluate the association between MIH and caries; the chi-square test was used to analyze the association between categorical variables, and the Mann-Whitney test was used to compare means. The final sample comprised 57 children in the case group and 98 in the control group. The groups were similar in relation to age, gender, and caries experience in the primary dentition. MIH children were 5.89 (95 percent confidence interval equals 2.69 to 12.86; P<0.05) times more likely to have a DMF-T greater than zero. Children with decayed, missing, or filled permanent teeth are more likely to have MIH.

  5. Accumulation and conversion of sugars by developing wheat grains. VII. Effect of changes in sieve tube and endosperm cavity sap concentrations on the grain filling rate

    International Nuclear Information System (INIS)

    Fisher, D.B.; Gifford, R.M.

    1987-01-01

    The extent to which wheat grain growth is dependent on transport pool solute concentration was investigated by the use of illumination and partial grain removal to vary solute concentrations in the sieve tube and endosperm cavity saps of the wheat ear (Triticum aestivum L.). Short-term grain growth rates were estimated indirectly from the product of phloem area, sieve tube sap concentration, and 32 P translocation velocity. On a per grain basis, calculated rates of mass transport through the peduncle were fairly constant over a substantial range in other transport parameters (i.e. velocity, concentration, phloem area, and grain number). The rates were about 40% higher than expected; this probably reflects some unavoidable bias on faster-moving tracer in the velocity estimates. Sieve tube sap concentration increased in all experiments (by 20 to 64%), with a concomitant decline in velocity (to as low as 8% of the initial value). Endosperm cavity sucrose concentration also increased in all experiments, but cavity sap osmolality and total amino acid concentration remained nearly constant. No evidence was found for an increase in the rate of mass transport per grain through the peduncle in response to the treatments. This apparent unresponsiveness of grain growth rate to increased cavity sap sucrose concentration conflicts with earlier in vitro endosperm studies showing that sucrose uptake increased with increasing external sucrose concentration up to 150 to 200 millimolar

  6. Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1978-02-01

    A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author)

  7. Laser fusion experiments at 2 TW. [Argus system; implosion of D-T filled glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Storm, E.K.; Ahlstrom, H.G.; Boyle, M.J.

    1976-10-01

    The Lawrence Livermore Laboratory Solid State Laser System, Arqus, has successfully performed laser implosion experiments at power levels exceeding 2 TW. D-T filled glass microspheres have been imploded to yield thermonuclear reaction products in excess of 5 x 10/sup 8/ per event. Neutron and ..cap alpha.. time-of-flight measurements indicate that D-T ion temperatures of approximately 5-6 keV and a density confinement time product (n tau) of approximately 1 x 10/sup 12/ were obtained in these experiments. Typically two 40J, 40 psec pulses of 1.06 ..mu..m light were focused on targets using 20 cm aperture f/1 lenses, producing intensities at the target in excess of 10/sup 16/ W/cm/sup 2/. An extensive array of diagnostics routinely monitored the laser performance and the laser target interaction process. Measurements of absorption and asymmetry in both the scattered light distribution and the ion blow off is evidence for non-classical absorption mechanisms and density scale heights of the order of 2 ..mu..m or less. The symmetry of the thermonuclear burn region is investigated by monitoring the ..cap alpha..-particle flux in several directions, and an experiment to image the thermonuclear burn region is in process. These experiments significantly extend our data base and our understanding of laser induced thermonuclear implosions and the basic laser plasma interaction physics from the 0.4 to 0.7 TW level of previous experiments.

  8. Steam generator tube integrity requirements and operating experience in the United States

    International Nuclear Information System (INIS)

    Karwoski, K.J.

    2009-01-01

    Steam generator tube integrity is important to the safe operation of pressurized-water reactors. For ensuring tube integrity, the U.S. Nuclear Regulatory Commission uses a regulatory framework that is largely performance based. This performance-based framework is supplemented with some prescriptive requirements. The framework recognizes that there are three combinations of tube materials and heat treatments currently used in the United States and that the operating experience depends, in part, on the type of material used. This paper summarizes the regulatory framework for ensuring steam generator tube integrity, it highlights the current status of steam generators, and it highlights some of the steam generator issues and challenges that exist in the United States. (author)

  9. Experiences of patients with abnormal extubation of PICC tubes: a qualitative study.

    Science.gov (United States)

    Gao, Wei; Luan, Xiao-Rong; Sun, Yuan-Yuan; Zhang, Ming; Li, Kan; Li, Qiu-Huan; Zhang, Hong; Liu, De-Shan

    2015-01-01

    To explore the experiences of patients with abnormal extubation of PICC tubes. Using phenomenological research methods, 15 cases of patients with abnormal extubation of PICC tubes were enrolled in semi-structured interviews. Data were analyzed by Nancy's phenomenological procedure. After abnormal extubation, patients exhibited conflicting complicated mood which combined negative experience and positive experience. Negative experience was mainly for complaint, helpless, worry and fear. Positive experience was mainly for relief and peace of mind. Patients with abnormal extubation often possessed negative experience. So nursing staff should be suggested to communicate with patients before extubation in order to reduce the dispute between nurses and patients. At the same time, we should summarize and analyze the reasons and factors for abnormal extubation, and take targeted intervention measures in clinical to ensure the safety and effectiveness of PICC extubation.

  10. Experiences of patients with abnormal extubation of PICC tubes: a qualitative study

    Science.gov (United States)

    Gao, Wei; Luan, Xiao-Rong; Sun, Yuan-Yuan; Zhang, Ming; Li, Kan; Li, Qiu-Huan; Zhang, Hong; Liu, De-Shan

    2015-01-01

    Objective: To explore the experiences of patients with abnormal extubation of PICC tubes. Methods: Using phenomenological research methods, 15 cases of patients with abnormal extubation of PICC tubes were enrolled in semi-structured interviews. Data were analyzed by Nancy’s phenomenological procedure. Results: After abnormal extubation, patients exhibited conflicting complicated mood which combined negative experience and positive experience. Negative experience was mainly for complaint, helpless, worry and fear. Positive experience was mainly for relief and peace of mind. Conclusions: Patients with abnormal extubation often possessed negative experience. So nursing staff should be suggested to communicate with patients before extubation in order to reduce the dispute between nurses and patients. At the same time, we should summarize and analyze the reasons and factors for abnormal extubation, and take targeted intervention measures in clinical to ensure the safety and effectiveness of PICC extubation. PMID:26770567

  11. Gas-filled Rugby hohlraum energetics and implosions experiments on OMEGA

    Science.gov (United States)

    Casner, Alexis; Philippe, F.; Tassin, V.; Seytor, P.; Monteil, M. C.; Villette, B.; Reverdin, C.

    2010-11-01

    Recent experiments [1,2] have validated the x-ray drive enhancement provided by rugby-shaped hohlraums over cylinders in the indirect drive (ID) approach to inertial confinement fusion (ICF). This class of hohlraum is the baseline design for the Laser Mégajoule program, is also applicable to the National Ignition Facility and could therefore benefit ID Inertial Fusion Energy studies. We have carried out a serie of energetics and implosions experiments with OMEGA ``scale 1'' rugby hohlraums [1,2]. For empty hohlraums these experiments provide complementary measurements of backscattered light along 42 cone, as well as detailed drive history. In the case of gas-filled rugby hohlraums we have also study implosion performance (symmetry, yield, bangtime, hotspot spectra...) using a high contrast shaped pulse leading to a different implosion regime and for a range of capsule convergence ratios. These results will be compared with FCI2 hydrocodes calculations and future experimental campaigns will be suggested. [4pt] [1] F. Philippe et al., Phys. Rev. Lett. 104, 035004 (2010). [0pt] [2] H. Robey et al., Phys. Plasnas 17, 056313 (2010).

  12. TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Freifeld, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-03-17

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-Tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  13. Synchronized and concurrent experiments in Moving Tube NMR: using separate sample volumes for different pulse sequences.

    Science.gov (United States)

    Donovan, Kevin J

    2014-10-01

    This study presents a new application of sample shuttling with a long NMR tube (Moving Tube NMR, MT-NMR) as a method for collecting different experiments synchronously or even concurrently using separate sample regions. Synchronized experiments were performed using an automated shuttling apparatus to move different sample regions into the coil between transients such that each experiment was collected using a separate, specific sample segment. Additionally, a 2D NOESY spectrum and a double quantum filtered COSY (DQCOSY) spectrum were collected concurrently by shuttling between two different sample regions during the NOESY mixing time. These applications of the Moving Tube technique show that it is a useful platform for compounded data acquisition to optimize spectrometer time by minimizing measurement times and avoiding problems arising from instrument and sample instabilities. Furthermore, collecting a DQCOSY during a 2D NOESY mixing time opens a wide array of possibilities, as this principle can be applied to collect any experiment during a NOESY mixing time provided that the mixing period is longer than the sum of the sample shuttling time plus a complete scan of the intermittent experiment. While this methodology relies on the use of a long sample tube, it does not require excessive sample volumes, as two milliliters is enough to constitute multiple sample regions. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    NARCIS (Netherlands)

    Aprile, E.; et al., [Unknown; Alfonsi, M.; Colijn, A.P.; Decowski, M.P.; Tiseni, A.; Tunnell, C.

    2015-01-01

    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company

  15. Developments for transactinide chemistry experiments behind the gas-filled separator TASCA

    International Nuclear Information System (INIS)

    Even, Julia

    2011-01-01

    Topic of this thesis is the development of experiments behind the gas-filled separator TASCA (TransActinide Separator and Chemistry Apparatus) to study the chemical properties of the transactinide elements. In the first part of the thesis, the electrodepositions of short-lived isotopes of ruthenium and osmium on gold electrodes were studied as model experiments for hassium. From literature it is known that the deposition potential of single atoms differs significantly from the potential predicted by the Nernst equation. This shift of the potential depends on the adsorption enthalpy of therndeposited element on the electrode material. If the adsorption on the electrode-material is favoured over the adsorption on a surface made of the same element as the deposited atom, the electrode potential is shifted to higher potentials. This phenomenon is called underpotential deposition. Possibilities to automatize an electro chemistry experiment behind the gas-filled separator were explored for later studies with transactinide elements. The second part of this thesis is about the in-situ synthesis of transition-metal-carbonyl complexes with nuclear reaction products. Fission products of uranium-235 and californium-249 were produced at the TRIGA Mainz reactor and thermalized in a carbon-monoxide containing atmosphere. The formed volatile metal-carbonyl complexes could be transported in a gas-stream. Furthermore, short-lived isotopes of tungsten, rhenium, osmium, and iridium were synthesised at the linear accelerator UNILAC at GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt. The recoiling fusion products were separated from the primary beam and the transfer products in the gas-filled separator TASCA. The fusion products were stopped in the focal plane of TASCA in a recoil transfer chamber. This chamber contained a carbon-monoxide - helium gas mixture. The formed metal-carbonyl complexes could be transported in a gas stream to various experimental setups. All

  16. Operational experience in the Langley expansion tube with various test gases

    Science.gov (United States)

    Miller, C. G.

    1977-01-01

    A resume' of operating experiences with the Langley Expansion Tube is presented. The driver gas was unheated helium at a nominal pressure of 5000 psi and the majority of the data presented are for air and carbon dioxide test gases. The primary purpose of these data is to illustrate the effects of various parameters on quasi-steady test flow duration, as well as free stream and post-normal shock flow conditions. The discussion shows that the Langley Expansion Tube is an operational facility capable of producing good quality, highly repeatable, quasi-steady flow for test times sufficient to establish flow about blunt axisymmetric and two-dimensional models.

  17. Quantitative evaluation of compactness of concrete-filled fiber-reinforced polymer tubes using piezoceramic transducers and time difference of arrival

    Science.gov (United States)

    Xu, Yang; Luo, Mingzhang; Hei, Chuang; Song, Gangbing

    2018-03-01

    Owing to its light weight and corrosion resistance, the concrete-filled fiber-reinforced polymer tube (CFFT) structure has a broad application prospect; the concrete compactness is key to the strength of CFFTs. To meet the urgent requirement of compactness monitoring of CFFTs, a quantitative method, which uses an array of four equally spaced piezoceramic patches and an ultrasonic time difference of arrival (TDOA) algorithm, is developed. Since the velocity of the ultrasonic wave propagation in fiber-reinforced polymer (FRP) material is about half of that in concrete material, the compactness condition of CFFT impacts the piezoceramic-induced wave propagation in the CFFT, and differentiates the TDOA for different receivers. An important condition is the half compactness, which can be judged by the Half Compactness Indicator (HCI) based on the TDOAs. To characterize the difference of stress wave propagation durations from the emitter to different receivers, which can be utilized to calculate the concrete infill compactness, the TDOA ratio (TDOAR) is introduced. An innovative algorithm is developed in this paper to estimate the compactness of the CFFT using HCI and TDOAR values. Analytical, numerical, and experimental studies based on a CFFT with seven different states of compactness (empty, 1/10, 1/3, 1/2, 2/3, 9/10, and full) are carried out in this research. Analyses demonstrate that there is a good agreement among the analytical, numerical, and experimental results of the proposed method, which employs a piezoceramic transducer array and the TDOAR for quantitative estimating the compactness of concrete infill in a CFFT.

  18. Improving the double quantum filtered COSY experiment by "Moving Tube" NMR.

    Science.gov (United States)

    Donovan, Kevin J; Allen, Mary; Martin, Rachel W; Shaka, A J

    2012-06-01

    Most 2D NMR spectra show artifacts that become increasingly more prominent as the relaxation delay between transients is decreased. Additionally, "rushing" a 2D experiment may lead to reduced sensitivity. It is shown here how to collect a DQF-COSY spectrum in less time, without artifacts, and with improved sensitivity, by a hardware solution we call Moving Tube NMR (MT NMR): the sample volume is physically moved out of the receiver coil after each transient and replaced by a fresh aliquot that is nearer to the equilibrium magnetization M(0). MT NMR was implemented with an automated mechanism that gave accurate and reproducible vertical tube movement, and a very long 5mm outer diameter (OD) NMR tube to hold a larger sample volume. Comparison of conventional and MT NMR DQF-COSY showed increased sensitivity and far reduced artifacts in the latter. The so-called t(1)-noise in the MT spectrum was no worse than in the conventional spectrum, pointing to the excellent specifications of the long 5mm OD tube, and the good mechanical handling of the automated drive. Thus, MT NMR could improve throughput for routine 2D NMR experiments without reducing sensitivity or adding artifacts, if sufficient sample is available. MT NMR could also be useful in cases of limited solubility, or for nuclei with long T(1) relaxation times. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Development and application of helium-filled soap bubbles : For large-scale PIV experiments in aerodynamics

    NARCIS (Netherlands)

    Caridi, Giuseppe Carlo Alp

    2018-01-01

    A new type of tracer is making its entry in the scenario of wind-tunnel measurements: helium-filled soap bubbles (HFSB). The present work discusses the main fluid-dynamic and optical properties of HFSB to evaluate their use for quantitative measurements in aerodynamic experiments.
    In the past

  20. On the use of helium-filled soap bubbles for large-scale tomographic PIV in wind tunnel experiments

    NARCIS (Netherlands)

    Scarano, F.; Ghaemi, S.; Alp Caridi, G.C.; Bosbach, J.; Dierksheide, U.; Sciacchitano, A.

    2015-01-01

    The flow-tracing fidelity of sub-millimetre diameter helium-filled soap bubbles (HFSB) for low-speed aerodynamics is studied. The main interest of using HFSB in relation to micron-size droplets is the large amount of scattered light, enabling larger-scale three-dimensional experiments by tomographic

  1. Heat Transfer Experiment with Supercritical CO2 Flowing Upward in a Circular Tube

    International Nuclear Information System (INIS)

    Kim, Hyung Rae; Kim, Hwan Yeol; Song, Jin Ho; Kim, Hee Dong; Bae, Yoon Yeong

    2005-01-01

    SCWR (SuperCritical Water-cooled Reactor) is one of the six reactor candidates selected in the Gen-IV project, which aims at the development of new reactors with enhanced economy and safety. Heat transfer experiments under supercritical conditions are required in relevant geometries for the proper prediction of thermo-hydraulic phenomena in a reactor core. A heat transfer test loop, named as SPHINX (Supercritical Pressure Heat Transfer Investigation for NeXt generation), has been constructed in KAERI. The loop uses carbon dioxide as a surrogate fluid for water since the critical pressure and temperature of CO 2 are much lower those of water. As a first stage of heat transfer experiments, a single tube test is being performed in the test loop. Controlled parameters for the tests are operating pressure, mass flux, and heat flux. Wall temperatures are measured along the tube. Experimental data are compared with existing correlations

  2. Optimal Design and Model Validation for Combustion Experiments in a Shock Tube

    KAUST Repository

    Long, Quan

    2014-01-06

    We develop a Bayesian framework for the optimal experimental design of the shock tube experiments which are being carried out at the KAUST Clean Combustion Center. The unknown parameters are the pre-exponential parameters and the activation energies in the reaction rate functions. The control parameters are the initial hydrogen concentration and the temperature. First, we build a polynomial based surrogate model for the observable related to the reactions in the shock tube. Second, we use a novel MAP based approach to estimate the expected information gain in the proposed experiments and select the best experimental set-ups corresponding to the optimal expected information gains. Third, we use the synthetic data to carry out virtual validation of our methodology.

  3. The performance of KSC Fixation Tubes with RNALater for orbital experiments: A case study in ISS operations for molecular biology

    Science.gov (United States)

    Ferl, Robert J.; Zupanska, Agata; Spinale, April; Reed, David; Manning-Roach, Susan; Guerra, George; Cox, David R.; Paul, Anna-Lisa

    2011-07-01

    Molecular biology experiments on the International Space Station (ISS) continue to face challenges of sample harvesting and sample return to earth for post flight analysis; however, the use of Kennedy Space Center Fixation Tubes filled with RNALater has proven to be a robust solution to many of these challenges. While it is clear that one direction of future spaceflight experimentation may be towards enhanced on-orbit analytical capabilities, the rapid progress of earth-bound analytical capacity dictates that facile return of molecular biology samples from the ISS will continue to be a mainstay of space life sciences research and flight operations. In this paper we present a case study of the successful performance of KFTs and RNALater over a broad set of operational conditions of ascent configuration, on-orbit experiment use, on-orbit storage and sample return configurations that are unique to ISS current operations and constraints. We also provide observations on performance limits and discuss deployment opportunities and scenarios that are consistent with continued successful ISS molecular biology experimentation.

  4. Structure optimization and performance experiments of a solar-powered finned-tube adsorption refrigeration system

    International Nuclear Information System (INIS)

    Ji, Xu; Li, Ming; Fan, Jieqing; Zhang, Peng; Luo, Bin; Wang, Liuling

    2014-01-01

    Highlights: • New-structure finned-tube adsorption bed for enhancing heat and mass transfer. • Temperatures on different parts of the adsorption tubes differ little. • Maximum COP of 0.122 and maximum daily ice-making of 6.5 kg are achieved by experiments. • Cooling efficiency of system with valve control higher than that without valve control. - Abstract: A large-diameter aluminum-alloy finned-tube absorbent bed collector was designed and optimized by enhancing the heat and mass transfer in the collector. The collection efficiency of the adsorbent bed collector was between 31.64% and 42.7%, and the temperature distribution in the absorbent bed was relatively uniform, beneficial to adsorption/desorption of the adsorbate in the absorbent bed. A solar-powered solid adsorption refrigeration system with the finned-tube absorbent bed collector was built. Some experiments corresponding to the adsorption/desorption process with and without a valve control were conducted in four typical weather conditions: sunny with clear sky, sunny with partly cloudy sky, cloudy sky and overcast sky. Activated carbon–methanol was utilized as the working pair for adsorption refrigeration in the experiments. The experiments achieved the maximum COP of 0.122 and the maximum daily ice-making of 6.5 kg. Under the weather conditions of sunny with clear sky, sunny with partly cloudy sky, and cloudy sky, ice-making phenomenon were observed. Even in the overcast-sky weather condition, the cooling efficiency of the system still reached 0.039 when the total solar radiation was 11.51 MJ. The cooling efficiency of the solar-powered adsorption refrigeration system with a valve control in the adsorption/desorption process was significantly higher than that without a valve control

  5. Experiments on vibro-impact dynamics of loosely supported tubes under harmonic excitation

    International Nuclear Information System (INIS)

    Axisa, F.; Izquierdo, P.

    1992-01-01

    Computational methods have been recently developed by the authors and others to predict the working life or the acceptable vibration limit of tubular structures experiencing fretting-wear caused by impact-sliding interaction with loose supports or adjacent structures. This problem is of practical interest in various nuclear and other industrial components. This paper reports an experimental work intended to validate the numerical techniques used to compute the tube non-linear vibration in presence of impact-sliding interaction. Attention is especially focused on the local and time averaged dynamical parameters governing the rate of fretting-wear. The experiments were carried out on a straight tube excited harmonically by a pair of electromagnetic shakers. The tube motion was limited by a loose support situated at about midspan. On the other hand, numerical simulations of the tests were also performed. Comparison between test and computational data resulted in rather satisfactory agreement, based on the averaged impact forces and the wear work rate. Results are also discussed in terms of detailed time histories of tube displacement and impact forces

  6. Experience of parents of children with autism on YouTube: are there educationally useful videos?

    Science.gov (United States)

    Azer, Samy A; Bokhari, Raghad A; AlSaleh, Ghadah S; Alabdulaaly, May M; Ateeq, Khawlah I; Guerrero, Anthony P S; Azer, Sarah

    2018-02-20

    The aims of this study were to determine the following: first, are there educationally useful videos of parents of children with autism sharing their experiences? Second, do any of the data related to videos help in identifying useful videos? And third, what do posted comments tell us? YouTube was searched for videos of parents sharing their experiences. The following parameters were collected: title, creator, URL, duration, number of viewers, likes, dislikes, comments, days on YouTube, and country. Based on agreed-upon criteria, videos were divided independently into educationally useful and non-useful categories. A critical thematic analysis of comments was conducted. A total of 180 videos were finally identified, of which 106 (59%) provided useful information, scoring 15.3 ± 0.7 (mean ± SD); 74 (41%) were determined to be not educationally useful, scoring 8.6 ± 2.1. The differences in scores were significant (p YouTube in sharing experiences.

  7. Annihilation and Reanimation of a Tornado in the Improved Tornado Tube

    Science.gov (United States)

    Bednarek, Stanislaw

    2016-01-01

    Some new experiments using an improved version of the "tornado tube" are described here. The improved tornado tube consists of two plastic transparent bottles whose openings are connected with a ball valve, available at most hardware stores. After being filled with fluid and inverting, this tube allows demonstration of the generation,…

  8. ePatients on YouTube: Analysis of Four Experiences From the Patients' Perspective

    Science.gov (United States)

    Gómez-Zúñiga, Beni; Pousada, Modesta; Hernández-Encuentra, Eulàlia; Armayones, Manuel

    2012-01-01

    Background Many patients share their personal experiences and opinions using online video platforms. These videos are watched by millions of health consumers and health care professionals. Although it has become a popular phenomenon, little is known about patients who share videos online and why they do so. Objective We aimed to explore the motivations and challenges faced by patients who share videos about their health and experiences on YouTube. As part of a conference discussion, we asked several patients actively engaged on YouTube to make a video explaining their motivations. This paper discusses these videos. Methods In this qualitative study, we performed an analysis of the videos created by 4 patients about their self-reported motivations and challenges they face as YouTube users. First, two judges compared the transcriptions and decided the exact wording when confusing content was found. Second, two judges categorized the content of the videos to identify the major themes. Results Four main categories emerged: (1) the origin or cause for making the first video, (2) the objectives that they achieve by continuing to make videos, (3) the perception of community, and (4) the negative consequences of the experience. Conclusions The main reason for making videos was to bridge the gap between traditional health information about their diseases and everyday life. The first consequence of sharing their life on YouTube was a loss of privacy. However, they also experienced the positive effects of expressing their feelings, being part of a large community of peers, and helping others to deal with a chronic condition. PMID:25075229

  9. The lived experience of a tracheostomy tube change: a phenomenological study.

    Science.gov (United States)

    Donnelly, Frank; Wiechula, Rick

    2006-09-01

    To investigate the lived experience patients have of a tracheostomy tube change. Few interpretive studies have looked at specific nursing interventions in relation to nursing practice. This study has investigated the lived experience of patients from an intensive care unit that have had a tracheostomy tube change. The tracheostomy is a significant intervention for many patients within critical care. Using a phenomenological approach, guided by the insights of Martin Heidegger and Max van Manen, participants were interviewed with their responses being transcribed into a text. This text has been subject to hermeneutic analysis using the theories of Paul Ricoeur. This hermeneutic approach has required using the text (discourse) as the focus of the interpretation. The findings of this study imply that the experience of a tracheostomy tube change is more complex than that of simply a physical sensation. There is a need for participants to prepare themselves psychologically, a process that requires not only the trust of nursing staff but also the assessment by the participant that the nursing staff member has a level of competence to perform the task. The need for maintaining communication and the ability to speak were at times more significant for participants than even the risk of other airway complications. This study has highlighted the potential for further interpretive studies into some of the more specific aspects of caring for patients that have been or are critically ill. The themes revealed will enable the nurse, required to change a tracheostomy tube, to do so with an improved level of empathy and understanding.

  10. "My Invisalign experience" : Content, metrics and comment sentiment analysis of the most popular patient testimonials on YouTube

    NARCIS (Netherlands)

    Livas, Christos; Delli, Konstantina; Pandis, Nikolaos

    2018-01-01

    BACKGROUND: The aim of the study was to investigate the popularity, content of Invisalign patient testimonials on YouTube, as well as the sentiment of the related comments. METHODS: Using the term "Invisalign experience," the top 100 results on YouTube by view count were screened for English spoken

  11. Self-assembly of "Mickey Mouse" shaped colloids into tube-like structures: experiments and simulations.

    Science.gov (United States)

    Wolters, Joost R; Avvisati, Guido; Hagemans, Fabian; Vissers, Teun; Kraft, Daniela J; Dijkstra, Marjolein; Kegel, Willem K

    2015-02-14

    The self-assembly of anisotropic patchy particles with a triangular shape was studied by experiments and computer simulations. The colloidal particles were synthesized in a two-step seeded emulsion polymerization process, and consist of a central smooth lobe connected to two rough lobes at an angle of ∼90°, resembling the shape of a "Mickey Mouse" head. Due to the difference in overlap volume, adding an appropriate depletant induces an attractive interaction between the smooth lobes of the colloids only, while the two rough lobes act as steric constraints. The essentially planar geometry of the Mickey Mouse particles is a first geometric deviation of dumbbell shaped patchy particles. This new geometry enables the formation of one-dimensional tube-like structures rather than spherical, essentially zero-dimensional micelles. At sufficiently strong attractions, we indeed find tube-like structures with the sticky lobes at the core and the non-sticky lobes pointing out as steric constraints that limit the growth to one direction, providing the tubes with a well-defined diameter but variable length both in experiments and simulations. In the simulations, we found that the internal structure of the tubular fragments could either be straight or twisted into so-called Bernal spirals.

  12. A conical-type X-ray guide tube for diffraction experiments with small crystals

    International Nuclear Information System (INIS)

    Nozaki, Hiroshi; Nakazawa, Hiromoto

    1986-01-01

    The divergence and intensity distribution of X-rays transported through a conical-type X-ray guide tube (XGT) were measured. Diverging X-rays from a point source were condensed by use of the conical-type XGT. The parallelism of X-rays through the XGT was better than that encountered for a cylindrical-type XGT proposed previously. The intensity of the X-ray beam around the central axis of the conical-type XGT was exceedingly high in comparison with that measured without the tube and almost uniform over a cross-sectional area 60 μm in diameter. The high intensity provides the possibility of performing diffraction experiments with crystals as small as 20 μm in diameter with a conventional X-ray diffraction system. (orig.)

  13. High temperature shock tube experiments and kinetic modeling study of diisopropyl ketone ignition and pyrolysis

    KAUST Repository

    Barari, Ghazal

    2017-03-10

    Diisopropyl ketone (DIPK) is a promising biofuel candidate, which is produced using endophytic fungal conversion. In this work, a high temperature detailed combustion kinetic model for DIPK was developed using the reaction class approach. DIPK ignition and pyrolysis experiments were performed using the UCF shock tube. The shock tube oxidation experiments were conducted between 1093K and 1630K for different reactant compositions, equivalence ratios (φ=0.5–2.0), and pressures (1–6atm). In addition, methane concentration time-histories were measured during 2% DIPK pyrolysis in argon using cw laser absorption near 3400nm at temperatures between 1300 and 1400K near 1atm. To the best of our knowledge, current ignition delay times (above 1050K) and methane time histories are the first such experiments performed in DIPK at high temperatures. Present data were used as validation targets for the new kinetic model and simulation results showed fair agreement compared to the experiments. The reaction rates corresponding to the main consumption pathways of DIPK were found to have high sensitivity in controlling the reactivity, so these were adjusted to attain better agreement between the simulation and experimental data. A correlation was developed based on the experimental data to predict the ignition delay times using the temperature, pressure, fuel concentration and oxygen concentration.

  14. EXPERIMENT BASED FAULT DIAGNOSIS ON BOTTLE FILLING PLANT WITH LVQ ARTIFICIAL NEURAL NETWORK ALGORITHM

    OpenAIRE

    Mustafa DEMETGÜL

    2008-01-01

    In this study, an artificial neural network is developed to find an error rapidly on pneumatic system. Also the ANN prevents the system versus the failure. The error on the experimental bottle filling plant can be defined without any interference using analog values taken from pressure sensors and linear potentiometers. The sensors and potentiometers are placed on different places of the plant. Neural network diagnosis faults on plant, where no bottle, cap closing cylinder B is not working, b...

  15. Laser-Plasma Interaction Experiments in Gas-Filled Hohlraums at the LIL Facility

    Science.gov (United States)

    Masson-Laborde, Paul-Edouard; Loiseau, Pascal; Casanova, Michel; Rousseaux, Christophe; Teychenne, Denis; Laffite, Stephane; Huser, Gael

    2009-11-01

    The first laser-plasma interaction campaign conducted at the LIL facility, using gas-filled hohlraums, ended in spring 09. Two different gas-filled hohlraums have been designed in order to mimic plasma conditions expected along two particular beam paths in ignition hohlraums. The targets consist of 3- or 4-millimeters long, 1 atm neo-pentane gas-filled gold hohlraums. The LIL quadruplet is aligned with the hohlraum's axis and delivers a 6-ns long pulse with 15 kJ at 3φ. Optical smoothing is achieved by longitudinal dispersion and a phase plate giving a near 10^15 W/cm^2 mean intensity on the focal spot at maximum power. Plasma conditions from hydrodynamic calculations allow to calcule SBS and SRS linear gain with the PIRANAH code. The calculated spectra are compared to experimental results. We use the paraxial code HERA to investigate the propagation of the LIL quad. Finally, 1D and 2D PIC simulations based on the plasma conditions of the cavity will be discussed in order to understand experimental SRS spectrum.

  16. Is Anesthesiologist’s experience important while inflating the endotracheal tube cuff with the right pressure?

    Directory of Open Access Journals (Sweden)

    Nesrin Turan

    2010-12-01

    Full Text Available Objectives: Cuff pressure in endotracheal tubes should be in the range of 26–30 cm H2O. In this study we aimed to examine whether anesthesiologist’s experience is important while inflating the endotracheal tube correctly after the intubation.Materials and methods: The patients who were included to the study were intubated after the induction of general anesthesia. The patients were divided into 4 groups according to the training year of the anesthesia research assistant resident inflating the endotracheal tube (ET cuff. Group I (n=64 the cuff pressure which were inflated by the first year residents; Group II (n=92 the cuff pressure which were inflated by the 2nd year residents; Group III (n=144 the cuff pressure which were inflated by the 3rd year residents; Group IV (n=93 the cuff pressure which were inflated by the 4th year residents were measured by manometer.Results: When we compared the cases in which the cuff pressure were between 26-30cm H2O we found that the best results were in Group II and respectively in Group III and IV and the worst results were in Group I. The difference between Group II and Group I were statistically significant (p<0.05.Conclusion: We believe that manometer should be used ET for cuff pressure setting and monitoring. J Clin Exp Invest 2010; 1(3: 195-198

  17. The drift tube track finder muon trigger at the CMS experiment

    CERN Document Server

    Jimenez, I

    2005-01-01

    The Compact Muon Solenoid (CMS) is a general purpose experiment designed to study proton-proton collisions at the Large Hadron Collider (LHC). At the LHC, proton beams will cross each other at a rate of 40 MHz, producing on average 20 p-p interactions. The CMS level-1 trigger must select interesting collisions at a rate smaller than 100 kHz. This report describes in particular the CMS drift tube track finder (DTTF) muon trigger. Its motivation, electronic implementation, and expected performance are presented.

  18. Design of the forward straw tube tracker for the PANDA experiment

    Science.gov (United States)

    Smyrski, J.; Apostolou, A.; Biernat, J.; Czyżycki, W.; Filo, G.; Fioravanti, E.; Fiutowski, T.; Gianotti, P.; Idzik, M.; Korcyl, G.; Korcyl, K.; Lisowski, E.; Lisowski, F.; Płażek, J.; Przyborowski, D.; Przygoda, W.; Ritman, J.; Salabura, P.; Savrie, M.; Strzempek, P.; Swientek, K.; Wintz, P.; Wrońska, A.

    2017-06-01

    The design of the Forward Tracker for the Forward Spectrometer of the PANDA experiment is described. The tracker consists of 6 tracking stations, each comprising 4 planar double layers of straw tube detectors, and has a total material budget of only 2% X0. The straws are made self-supporting by a 1 bar over-pressure of the working gas mixture (Ar/CO2). This allows to use lightweight and compact rectangular support frames for the double layers and to split the frames into pairs of C-shaped half-frames for an easier installation on the beam line.

  19. New contact boiling experiments to evaluate Calandria tube strain acceptance criteria

    Energy Technology Data Exchange (ETDEWEB)

    El-Hawary, M.; Szymanski, J.; Tanase, A.; Delja, A.; Oussoren, A., E-mail: Magdy.El-Hawary@cnsc-ccsn.gc.ca [Canadian Nuclear Safety Comission, Ottawa, ON (Canada); Neal, P. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    The Canadian Nuclear Safety Commission(CNSC) has contracted the Canadian Nuclear Laboratories(CNL) to conduct additional Contact Boiling (CB) experiments with the main objective of evaluating the acceptance criterion of CalandriaTube (CT) strain limit of 2%, proposed by the industry for fuel channel integrity assessments. The test conditions are selected using analytical tools and guidance from existing CANDU Owners Group (COG) test results, so as to lead to CT strain close to this value. The experiments will also be used to evaluate the CT quench temperature correlation proposed. This paper presents conditions selected for the first three experiments, their most important results and their preliminary analysis, with a focus on the test which produced CT strain in excess of 2%. (author)

  20. EXPERIMENT BASED FAULT DIAGNOSIS ON BOTTLE FILLING PLANT WITH LVQ ARTIFICIAL NEURAL NETWORK ALGORITHM

    Directory of Open Access Journals (Sweden)

    Mustafa DEMETGÜL

    2008-01-01

    Full Text Available In this study, an artificial neural network is developed to find an error rapidly on pneumatic system. Also the ANN prevents the system versus the failure. The error on the experimental bottle filling plant can be defined without any interference using analog values taken from pressure sensors and linear potentiometers. The sensors and potentiometers are placed on different places of the plant. Neural network diagnosis faults on plant, where no bottle, cap closing cylinder B is not working, bottle cap closing cylinder C is not working, air pressure is not sufficient, water is not filling and low air pressure faults. The fault is diagnosed by artificial neural network with LVQ. It is possible to find an failure by using normal programming or PLC. The reason offing Artificial Neural Network is to give a information where the fault is. However, ANN can be used for different systems. The aim is to find the fault by using ANN simultaneously. In this situation, the error taken place on the pneumatic system is collected by a data acquisition card. It is observed that the algorithm is very capable program for many industrial plants which have mechatronic systems.

  1. Should Children With Cleft Palate Receive Early Long-Term Tympanostomy Tubes: One Institution's Experience.

    Science.gov (United States)

    Shaffer, Amber D; Ford, Matthew D; Choi, Sukgi S; Jabbour, Noel

    2018-03-01

    To determine whether children with cleft palate might benefit from early long-term tympanostomy tubes with the hypothesis that receiving multiple tubes is associated with shorter duration of first tubes. Retrospective cohort study. Tertiary care children's hospital. Records from 401 consecutive children with cleft palate ± cleft lip, born April 2005 to April 2010, were reviewed. After exclusion of children with cleft repair at an outside hospital, no follow-up after 5 years of age, intact secondary palate, no tubes, or tube replacement at palatoplasty, 105 children remained. Number of tubes. Armstrong grommet tubes were placed at a median age of 6.7 months (range 2.3-19.6 months). Tubes were replaced in 55.3% of patients, with 34.0% receiving ≥3 sets. Duration of first tubes was significantly longer for children with 1 set of tubes compared with those with multiple sets (median 26 vs 19 months, P = .004). Otorrhea, but not perforation, was associated with longer duration of first tubes (median 27 vs 20.5 months, P = .028). Cleft type did not impact the proportion of patients with multiple tubes. Median age at last tube placement for children with multiple tubes was 5.0 years (range 1.9-8.7 years). Short duration of first tubes is associated with receiving multiple tubes. Because most patients require repeat tubes and many require tubes until school age, there is a significant need for controlled, prospective trials of early long-term tube placement in this population.

  2. Versatile fill coils: initial experience as framing coils for oblong aneurysms. A technical case report.

    Science.gov (United States)

    Osanai, Toshiya; Bain, Mark; Hui, Ferdinand K

    2014-01-01

    Coil embolization of oblong aneurysms is difficult because the majority of commercially available coils are manufactured with a helical or spherical tertiary structure. While adopting framing strategies for oblong aneurysms (aspect ratio ≥ 2: 1), traditional coils may be undersized in the long axis but oversized in the short axis, resulting in increased aneurysmal wall stress, risk of re-rupture, and difficulty creating a basket that respects the aneurysmal neck. We review three cases in which versatile filling coils (VFCs) were used as the initial coils for embolization of oblong aneurysms and report coil distribution characteristics and clinical outcomes. Packing density after VFC implantation was assessed using the software AngioSuite-Neuro edition and AngioCalc. a 58-year-old woman experienced a subarachnoid hemorrhage from a ruptured anterior communicating artery aneurysm (7.5 mm × 3.5 mm). A 3-6 mm × 15 cm VFC was selected as the first coil because the flexibility of its wave-loop structure facilitates framing of an irregularly shaped aneurysm. The loop portions of the structures tend to be pressed to the extremes of the aneurysmal sac by the wave component. The VFC was introduced smoothly into the aneurysmal sac without catheter kickback. We were then able to insert detachable filling coils without any adjunctive technique and achieved complete occlusion. Complete occlusion without severe complications was achieved in all three cases in our study. Average packing density after the first coil was 15.63%. VFC coils may have a specific role in framing oblong aneurysms given their complex loop-wave design, allowing spacing of the coils at the dome and neck while keeping sac stress to a minimum.

  3. Patient and Family Caregivers’ Experiences of Living With a Jejunostomy Feeding Tube After Surgery for Esophagogastric Cancer

    OpenAIRE

    Halliday, V.; Baker, M.; Thomas, A.L.; Bowrey, D.

    2017-01-01

    BACKGROUND: Jejunostomy feeding tubes (JFTs) can be used to provide nutrition support to patients who have had surgery for esophagogastric cancer. Although previous research reports how patients cope with a gastrostomy tube, little is known about the impact of having a JFT. The aim of this qualitative study was to explore how patients and their informal caregivers experience living with a JFT in the first months following surgery. METHODS: Participants were purposively sampled from a cohort o...

  4. Steam generator tube performance. Experience with water-cooled nuclear power reactors during 1985

    International Nuclear Information System (INIS)

    Tatone, O.S.; Tapping, R.L.

    1988-12-01

    The performance of steam generator tubes at water-cooled reactors during 1985 has been reviewed. Seventy-three of 168 reactors in the survey experienced tube degradation sufficient for the tubes to be plugged. The number of tubes plugged was 6837 or 0.28% of those in service. The leading cause of tube failure was stress corrosion cracking from the primary side. Stress corrosion cracking or intergranular attack from the secondary side and pitting were also major causes of tube failure. Unlike most previous years, fretting was a substantial problem at some reactors. Overall, corrosion continued to account for more than 80% of the defects. 20 refs

  5. Access to health care for children with neural tube defects: Experiences of mothers in Zambia

    Directory of Open Access Journals (Sweden)

    Micah M. Simpamba

    2016-02-01

    Full Text Available Introduction: In Zambia, all children born with neural tube defects requiring surgery need to be referred to a tertiary level hospital in Lusaka, the capital city, where the specialists are based. The aim of this study was to explore the experiences of mothers accessing health care who had recently given birth to a child with a neural tube defect. Methods and analysis: In-depth interviews were conducted with a purposively selected sample of 20 mothers at the tertiary level hospital. The interviews were audiotaped, transcribed verbatim and translated. Content analysis was used to identify codes, which were later collapsed into categories and themes. Findings: Five themes emerged: access to health care, access to transport, access to information, concerns about family and support needs. Discussion: Barriers to access to health care included geographical barriers and barriers linked to availability. Geographical barriers were related to distance between home and the health centre, and referral between health facilities. Barriers to availability included the lack of specialist health workers at various levels, and insufficient hospital vehicles to transport mothers and children to the tertiary level hospital. The main barrier to affordability was the cost of transport, which was alleviated by either family or government support. Acceptability of the health services was affected by a lack of information, incorrect advice, the attitude of health workers and the beliefs of the family. Conclusion: Access to health care by mothers of children with neural tube defects in Zambia is affected by geographical accessibility, availability, affordability and acceptability. The supply-side barriers and demand-side barriers require different interventions to address them. This suggests that health policy is needed which ensures access to surgery and follow-up care.

  6. Access to health care for children with neural tube defects: Experiences of mothers in Zambia.

    Science.gov (United States)

    Simpamba, Micah M; Struthers, Patricia M; Mweshi, Margaret M

    2016-01-01

    In Zambia, all children born with neural tube defects requiring surgery need to be referred to a tertiary level hospital in Lusaka, the capital city, where the specialists are based. The aim of this study was to explore the experiences of mothers accessing health care who had recently given birth to a child with a neural tube defect. In-depth interviews were conducted with a purposively selected sample of 20 mothers at the tertiary level hospital. The interviews were audiotaped, transcribed verbatim and translated. Content analysis was used to identify codes, which were later collapsed into categories and themes. Five themes emerged: access to health care, access to transport, access to information, concerns about family and support needs. Barriers to access to health care included geographical barriers and barriers linked to availability. Geographical barriers were related to distance between home and the health centre, and referral between health facilities. Barriers to availability included the lack of specialist health workers at various levels, and insufficient hospital vehicles to transport mothers and children to the tertiary level hospital. The main barrier to affordability was the cost of transport, which was alleviated by either family or government support. Acceptability of the health services was affected by a lack of information, incorrect advice, the attitude of health workers and the beliefs of the family. Access to health care by mothers of children with neural tube defects in Zambia is affected by geographical accessibility, availability, affordability and acceptability. The supply-side barriers and demand-side barriers require different interventions to address them. This suggests that health policy is needed which ensures access to surgery and follow-up care.

  7. Experiments on vibration of heat exchanger tube arrays in cross flow

    International Nuclear Information System (INIS)

    Blevins, R.D.; Gibert, R.J.; Villard, B.

    1981-08-01

    A series of tests have been made at the Commissariat a l'Energie Atomique, in cooperation with General Atomic Company, SAN DIEGO (U.S.A.) on the flow-induced vibration of heat exchanger tube bundles in cross flow. These tests were made in air on tube bundles which simulated heat exchangers in the high temperature gas cooled reactors. The tests were of two types. In the first type, an instrumented tube was inserted at various locations into a tube bundle. Measurements were made of pressure at a number of points along the tube and about the circumference of the tube. These measurements were processed to obtain the spectra of turbulent pressure fluctuations on the tube, the spanwise correlation and the lift force. The second set of tests was made on tube bundles with flexible tubes. As the flow velocity was increased, these tests clearly show an instability. Nine tube configurations were tested with both plastic and metallic tubes and the effect of tube-to-tube difference in natural frequency was investigated

  8. A Simple Test Tube-Based ELISA Experiment for the High-School Classroom.

    Science.gov (United States)

    Brokaw, Ann; Cobb, Brian A

    2009-07-01

    Immunology is gaining prominence both in the media as well as on the Advanced Placement (AP) exam in Biology. One of the challenges of teaching modern biological topics such as immunology and biochemistry in the high-school setting is the increased reliance on expensive technology in the research world. To begin to bridge this widening gap, we devised an experiment using a novel macroscale enzyme-linked immunosorbent assay that is suitable for AP-level high-school biology classrooms as well as entry-level collegiate laboratories. This novel method does not require a plate reader for data analysis, but instead relies on more common and inexpensive equipment such as a clinical test tube centrifuge and a simple test tube spectrophotometer. The experimental plan focuses on students measuring antibody concentrations in "unknown" samples and includes the collection and analysis of a standard curve using reagents prepared by the instructor. Students will be introduced to enzyme action, quantitative laboratory technique, antibodies, and the immune system, with the overall goal being to explore and highlight the inherent connections within the fields of biochemistry and immunology.

  9. A Simple Test Tube-Based ELISA Experiment for the High-School Classroom*

    Science.gov (United States)

    Brokaw, Ann; Cobb, Brian A.

    2010-01-01

    Immunology is gaining prominence both in the media as well as on the Advanced Placement (AP) exam in Biology. One of the challenges of teaching modern biological topics such as immunology and biochemistry in the high-school setting is the increased reliance on expensive technology in the research world. To begin to bridge this widening gap, we devised an experiment using a novel macroscale enzyme-linked immunosorbent assay that is suitable for AP-level high-school biology classrooms as well as entry-level collegiate laboratories. This novel method does not require a plate reader for data analysis, but instead relies on more common and inexpensive equipment such as a clinical test tube centrifuge and a simple test tube spectrophotometer. The experimental plan focuses on students measuring antibody concentrations in “unknown” samples and includes the collection and analysis of a standard curve using reagents prepared by the instructor. Students will be introduced to enzyme action, quantitative laboratory technique, antibodies, and the immune system, with the overall goal being to explore and highlight the inherent connections within the fields of biochemistry and immunology. PMID:20689684

  10. The Power System Detector Control System of the Monitored Drift Tubes of the ATLAS Experiment

    CERN Document Server

    Alexopoulos, T; Bachtis, M; Argyropoulos, T; Gazis, E; Lliopoulos, A; Mountricha, E; Tsipolitis, G; Vlachos, S

    2008-01-01

    In this note the Detector Control System (DCS) for the power supply (PS) of the Monitored Drift Tube (MDT) chambers of the ATLAS experiment is presented. The principal task of DCS is to enable and ensure the coherent and safe operation of the detector. The interaction of the detector experts users or shifters with the detector hardware is also performed via DCS. This system monitors the operational parameters and the overall state of the detector, the alarm generation and handling, the connection of hardware values to databases and the interaction with the Data Acquisition system (DAQ). In this note the Power System (PS) system as a Detector Control Subsystem is presented. Furthermore, it is outlined in detail what is the front-end to be controlled and how the architecture of the back-end is established.

  11. The role of background music in the experience of watching YouTube videos about death and dying

    Directory of Open Access Journals (Sweden)

    Panagiotis Pentaris

    2015-12-01

    Full Text Available YouTube is the largest video sharing site live at the moment. It has been used to communicate a vast array of information, while it allows for user-generated content. This paper will focus on YouTube videos that communicate death, and in particular will present findings from a preliminary study undertaken by the authors considering the role that background music plays in these videos. Specifically, this study explores the experiences of the viewers of death-related YouTube videos with and without background music while it makes comparisons in relation to the impact that music has on the viewers’ emotional experiences. We conclude that background music elicits emotions and enhances feelings of sadness and sympathy in relation to the visual content of videos while recommendations for future research are made.

  12. A Freon-filled bubble chamber for neutron detection in inertial confinement fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ghilea, M. C.; Meyerhofer, D. D.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States)

    2011-03-15

    Neutron imaging is one of the main methods used in inertial confinement fusion experiments to measure the core symmetry of target implosions. Previous studies have shown that bubble chambers have the potential to obtain higher resolution images of the targets for a shorter source-to-target distance than typical scintillator arrays. A bubble chamber for neutron imaging with Freon 115 as the active medium was designed and built for the OMEGA laser system. Bubbles resulting from spontaneous nucleation were recorded. Bubbles resulting from neutron-Freon interactions were observed at neutron yields of 10{sup 13} emitted from deuterium-tritium target implosions on OMEGA. The measured column bubble density was too low for neutron imaging on OMEGA but agreed with the model of bubble formation. The recorded data suggest that neutron bubble detectors are a promising technology for the higher neutron yields expected at National Ignition Facility.

  13. A Freon-filled bubble chamber for neutron detection in inertial confinement fusion experiments

    Science.gov (United States)

    Ghilea, M. C.; Meyerhofer, D. D.; Sangster, T. C.

    2011-03-01

    Neutron imaging is one of the main methods used in inertial confinement fusion experiments to measure the core symmetry of target implosions. Previous studies have shown that bubble chambers have the potential to obtain higher resolution images of the targets for a shorter source-to-target distance than typical scintillator arrays. A bubble chamber for neutron imaging with Freon 115 as the active medium was designed and built for the OMEGA laser system. Bubbles resulting from spontaneous nucleation were recorded. Bubbles resulting from neutron-Freon interactions were observed at neutron yields of 1013 emitted from deuterium-tritium target implosions on OMEGA. The measured column bubble density was too low for neutron imaging on OMEGA but agreed with the model of bubble formation. The recorded data suggest that neutron bubble detectors are a promising technology for the higher neutron yields expected at National Ignition Facility.

  14. Unified law of evolution of experimental gouge-filled fault for fast and slow slip events at slider frictional experiments

    Science.gov (United States)

    Ostapchuk, Alexey; Saltykov, Nikolay

    2017-04-01

    Excessive tectonic stresses accumulated in the area of rock discontinuity are released while a process of slip along preexisting faults. Spectrum of slip modes includes not only creeps and regular earthquakes but also some transitional regimes - slow-slip events, low-frequency and very low-frequency earthquakes. However, there is still no agreement in Geophysics community if such fast and slow events have mutual nature [Peng, Gomberg, 2010] or they present different physical phenomena [Ide et al., 2007]. Models of nucleation and evolution of fault slip events could be evolved by laboratory experiments in which regularities of shear deformation of gouge-filled fault are investigated. In the course of the work we studied deformation regularities of experimental fault by slider frictional experiments for development of unified law of evolution of fault and revelation of its parameters responsible for deformation mode realization. The experiments were conducted as a classic slider-model experiment, in which block under normal and shear stresses moves along interface. The volume between two rough surfaces was filled by thin layer of granular matter. Shear force was applied by a spring which deformed with a constant rate. In such experiments elastic energy was accumulated in the spring, and regularities of its releases were determined by regularities of frictional behaviour of experimental fault. A full spectrum of slip modes was simulated in laboratory experiments. Slight change of gouge characteristics (granule shape, content of clay), viscosity of interstitial fluid and level of normal stress make it possible to obtained gradual transformation of the slip modes from steady sliding and slow slip to regular stick-slip, with various amplitude of 'coseismic' displacement. Using method of asymptotic analogies we have shown that different slip modes can be specified in term of single formalism and preparation of different slip modes have uniform evolution law. It is shown

  15. Near-critical density filling of the SF6 fluid cell for the ALI-R-DECLIC experiment in weightlessness

    Science.gov (United States)

    Lecoutre, C.; Marre, S.; Garrabos, Y.; Beysens, D.; Hahn, I.

    2018-05-01

    Analyses of ground-based experiments on near-critical fluids to precisely determine their density can be hampered by several effects, especially the density stratification of the sample, the liquid wetting behavior at the cell walls, and a possible singular curvature of the "rectilinear" diameter of the density coexisting curve. For the latter effect, theoretical efforts have been made to understand the amplitude and shape of the critical hook of the density diameter, which depart from predictions from the so-called ideal lattice-gas model of the uniaxial 3D-Ising universality class. In order to optimize the observation of these subtle effects on the position and shape of the liquid-vapor meniscus in the particular case of SF6, we have designed and filled a cell that is highly symmetrized with respect to any median plane of the total fluid volume. In such a viewed quasi-perfect symmetrical fluid volume, the precise detection of the meniscus position and shape for different orientations of the cell with respect to the Earth's gravity acceleration field becomes a sensitive probe to estimate the cell mean density filling and to test the singular diameter effects. After integration of this cell in the ALI-R insert, we take benefit of the high optical and thermal performances of the DECLIC Engineering Model. Here we present the sensitive imaging method providing the precise ground-based SF6 benchmark data. From these data analysis it is found that the temperature dependence of the meniscus position does not reflect the expected critical hook in the rectilinear density diameter. Therefore the off-density criticality of the cell is accurately estimated, before near future experiments using the same ALI-R insert in the DECLIC facility already on-board the International Space Station.

  16. Alignment of the drift tube detector at the neutrino oscillation experiment OPERA

    International Nuclear Information System (INIS)

    Goellnitz, Christoph

    2012-09-01

    The present thesis was composed during the course of the OPERA experiment, which aims to give a direct evidence for neutrino oscillations in the channel ν μ → ν τ . The OPERA detector is designed to observe the appearance of tau neutrinos in an originally pure muon neutrino beam, the CNGS beam. As important part of the detector the precision tracker (PT), a drift tube detector, consists of 9504 drift tubes in 198 modules. In this thesis, several parts of the slow control of the PT are developed and implemented to ensure operation during data taking over several years. The main part is the geometric calibration, the alignment of the detector. The alignment procedure contains both hardware and software parts, the software methods are developed and applied. Using straight particle tracks, the detector components are geometrically corrected. A special challenge for the alignment for the PT is the fact that at this kind of low-rate experiment only a small number of particle tracks is available. With software-based corrections of the module rotation, a systematic error of 0.2 mrad has been attained, for corrections of translation, a systematic error of 32 μm is reached. For the alignment between two adjacent PT walls, the statistical error is less than 8 μm. All results of the position monitoring system are considered. All developed methods are tested with Monte Carlo simulations. The detector requirements (Δp/p ≤ 0.25 below 25 GeV) are met. The analysis of the momentum measurement for high energies above 25 GeV demonstrates the resulting improvement. The mean momentum is falling significantly using the new alignment values. The significance of the detector alignment becomes most evident in the analysis of cosmic particles. The muon charge ratio R μ is expected not to be angular dependent. The χ 2 probability of the measured distribution improves up to 58%. The muon charge ratio was also investigated in dependence of particle energy in terms of the alignment

  17. Investigating pyroclast ejection dynamics using shock-tube experiments: temperature, grain size and vent geometry effects.

    Science.gov (United States)

    Cigala, V.; Kueppers, U.; Dingwell, D. B.

    2015-12-01

    Explosive volcanic eruptions eject large quantities of gas and particles into the atmosphere. The portion directly above the vent commonly shows characteristics of underexpanded jets. Understanding the factors that influence the initial pyroclast ejection dynamics is necessary in order to better assess the resulting near- and far-field hazards. Field observations are often insufficient for the characterization of volcanic explosions due to lack of safe access to such environments. Fortunately, their dynamics can be simulated in the laboratory where experiments are performed under controlled conditions. We ejected loose natural particles from a shock-tube while controlling temperature (25˚ and 500˚C), overpressure (15MPa), starting grain size distribution (1-2 mm, 0.5-1 mm and 0.125-0.250 mm), sample-to-vent distance and vent geometry. For each explosion we quantified the velocity of individual particles, the jet spreading angle and the production of fines. Further, we varied the setup to allow for different sample-to-gas ratios and deployed four different vent geometries: 1) cylindrical, 2) funnel with a flaring of 30˚, 3) funnel with a flaring of 15˚ and 4) nozzle. The results showed maximum particle velocities up to 296 m/s, gas spreading angles varying from 21˚ to 37˚ and particle spreading angles from 3˚ to 40˚. Moreover we observed dynamically evolving ejection characteristics and variations in the production of fines during the course of individual experiments. Our experiments mechanistically mimic the process of pyroclast ejection. Thus the capability for constraining the effects of input parameters (fragmentation conditions) and conduit/vent geometry on ballistic pyroclastic plumes has been clearly established. These data obtained in the presence of well-documented conduit and vent conditions, should greatly enhance our ability to numerically model explosive ejecta in nature.

  18. Chapter 8: Exponential experiments on graphite moderated lattices fuelled by natural uranium tubes containing cylindrical graphite cores

    International Nuclear Information System (INIS)

    McCulloch, D.B.; Hoskins, T.A.

    1963-01-01

    Experiments have been carried out using a fuel element comprising a 2.75 in. o.d./2.40 in. i.d. natural uranium tube containing a graphite core of diameter 2.0 in. Values of material buckling and migration area asymmetry for lattices at 7 in., 8 in. and 8/2 in. pitch have been obtained, and correlated with the theory of Syrett (1961) to derive an effective resonance integral for the cored element. By comparison with the resonance integral for the same fuel tube without a core, a value for the constant 'γ' of the theory of Stace (1959) is obtained. (author)

  19. Experiments on ballooning in pressurized and transiently heated Zircaloy-4 tubes

    International Nuclear Information System (INIS)

    Markiewicz, M.E.; Erbacher, F.J.

    1988-02-01

    Single-rod burst tests were performed with Atucha I Zircaloy-4 cladding tubes in the REBEKA burst equipment of KfK. The objective was to investigate the ballooning and burst behavior of argentine cladding tubes obtained from NRG, Germany and CONVAR, Argentina. The burst data were compared with those of cladding tubes used in german PWR's. It was found that the burst data e.g. burst temperature, circumferential burst strain and its response to azimuthal temperature differences are identical for the Argentine and German tubing quality. The burst data are in good agreement with those of German PWR-Zircaloy tubes. Thus, the fuel rod behavior codes developed for German PWR's can also be used for the Argentine reactor Atucha I. (orig.) [de

  20. Shock tube experiments on nitromethane and Promotion of chemical reactions by non-thermal plasma

    Energy Technology Data Exchange (ETDEWEB)

    Seljeskog, Morten

    2002-06-01

    This dissertation was undertaken to study two different subjects both related to molecular decomposition by applying a shock tube and non-thermal plasma to decompose selected hydrocarbons. The first approach to molecular decomposition concerned thermal decomposition and oxidation of highly diluted nitromethane (NM) in a shock tube. Reflected shock tube experiments on NM decomposition, using mixtures of 0.2 to 1.5 vol% NM in nitrogen or argon were performed over the temperature range 850-1550 K and pressure range 190-900 kPa, with 46 experiments diluted in nitrogen and 44 diluted in argon. By residual error analysis of the measured decomposition profiles it was found that NM decomposition (CH{sub 3}NO{sub 2} + M {yields} CH{sub 3} + NO{sub 2} + M, where M = N{sub 2} /Ar) corresponds well to a law of first order. Arrhenius expressions corresponding to NM diluted either in N{sub 2} or in Ar were found as k{sub N2} = 10{sup 17.011} * exp(- 182.6 kJ/mole / R*T) and k{sub Ar} = 10{sup 17.574}*exp(-207 kJ/mole / R*T ) , respectively. A new reaction mechanism was then proposed, based on new experimental data for NM decomposition both in Ar and N{sub 2} and on three previously developed mechanisms. The new mechanism predicts well the decomposition of NM diluted in both N{sub 2} and Ar within the pressure and temperature range covered by the experiments. In parallel to, and following the decomposition experiments, oxidative experiments on the ignition delay times of NM/O{sub 2}/Ar mixtures were investigated over high temperature and low to high pressure ranges. These experiments were carried out with eight different mixtures of gaseous NM and oxygen diluted in argon, with pressures ranging between 44.3-600 kPa, and temperatures ranging between 842-1378 K. The oxidation experiments were divided into different categories according to the type of decomposition signals achieved. For signals with and without emission, the apparent quasi

  1. Experience with a new ultrasonic inspection system for non-destructive examination of canning tubes

    International Nuclear Information System (INIS)

    Gundtoft, H.E.; Nielsen, T.; Agerup, C.C.

    1976-05-01

    The Risoe/HV Tube Inspection System is designed for the fast automatic inspection of precision tubes. Work has been carried out on this system for the last 3 years. Its accuracy and stability have been improved by innovation in both the mechanical system (specially the water circulation and temperature regulation) and the electronic modules (the ultrasonic equipment). Also the ultrasonic transducers have been studied and changed. The calibration procedure has been simplified and furthermore improved, both for dimensions and defects. (author)

  2. Collision Experiment of an Arched Plasma-Filled Flux Rope and a Target Cloud of Initially Neutral Gas

    Science.gov (United States)

    Wongwaitayakornkul, Pakorn; Bellan, Paul; Li, Hui; Li, Shengtai

    2016-10-01

    Shocks occur in the co-rotating interaction regions just beyond the solar corona, in the corona during CME events, and when the solar wind impacts Earth's magnetosphere. The Caltech solar loop experiment investigates shock physics by creating an arched plasma-filled flux rope that expands to collide with a pre-injected, initially-neutral gas. We focus the investigation on the situation of a heavy-gas plasma (Argon) impacting a much lighter neutral gas cloud (Hydrogen). The neutral gas target cloud ionizes immediately upon being impacted and plasma-induced shock waves propagate in the target cloud away from the impact region. Analysis of data from magnetic probes, Langmuir probes, a fast camera, and spectroscopic measurements will be presented. The measurements suggest that a thin, compressed, ionized layer of hydrogen is formed just downstream of the Argon plasma loop and that thin, supersonic shocks form further downstream and propagate obliquely away from the plasma loop. Numerical simulation of an ideal MHD plasma is underway to enable comparison of the measurements with the predictions of MHD theory.

  3. An External Condensation Heat Transfer Experiment for a Vertical Finned Tube

    International Nuclear Information System (INIS)

    Jang, Yeong Jun; Choi, Dong Jae; Lee, Yeon Gun; Kim, Sin

    2016-01-01

    The Passive Containment Cooling System (PCCS) that will be introduced in the next generation Korean nuclear power plant guarantee the safety of the nuclear power to utilize the condensation heat transfer phenomenon. The condensation heat transfer phenomenon plays a key role in the event of the loss of coolant accident (LOCA) or main steam line break (MSLB) in suppressing the pressurization of the containment. Therefore, the heat capacity of the PCCS is an important factor. This study focused to investigate the condensation heat transfer on a vertical finned tube for increase of the heat capacity by the fins under natural convection conditions. The 13 fins are installed along the tube height, uniformly. Experimental results show that the condensation HTR reduces with an increase of the noncondensable gas mass fraction because the noncondensable gas acts as a resistance during the condensation phenomena. The fin for the increment of the effective heat transfer area affects the condensation HTR. The fin plays a positive role due to the increment of the effective heat transfer area. However, the condensate decreases the condensation HTR. Especially, a retention area of the condensate is the one of the main parameter for the HTR of the disc type finned tube. In a view of the applicability to PCCS, for the single finned tube, HTR is higher than the bare tube, though the ratio of the HTR is the smaller than the ratio of the area.

  4. A Barrel IFR Instrumented With Limited Streamer Tubes for BABAR Experiment

    International Nuclear Information System (INIS)

    Andreotti, M.; Ferrara U.; INFN, Ferrara

    2006-01-01

    The new barrel Instrumented Flux Return (IFR) of BABAR detector will be reported here. Limited Streamer Tubes (LSTs) have been chosen to replace the existing RPCs as active elements of the barrel IFR. The layout of the new detector will be discussed: in particular, a cell bigger than the standard one has been used to improve efficiency and reliability. The extruded profile is coated with a resistive layer of graphite having a typical surface resistivity between 0.2 and 0.4 MOhm/square. The tubes are assembled in modules and installed in 12 active layers of each sextant of the IFR detector. R and D studies to choose the final design and Quality Control procedure adopted during the tube production will be briefly discussed. Finally the performances of installed LSTs into 2/3 of IFR after 8 months of operations will be reported

  5. Filled Craters

    Science.gov (United States)

    2006-01-01

    11 May 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows adjacent impact craters located north-northwest of the Acheron Fossae region of Mars. The two craters are of similar size and formed by meteor impacts. However, one is much more filled than the other, indicating that it is older. The surface of the material in the older, partially-filled crater has a texture similar to the crater's surroundings. The southern (bottom) crater is bowl-shaped and is also partially-filled, however, the filling material seems to be limited to the southern half of the crater. Location near: 44.6oN, 128.4oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Northern Winter

  6. First experience using 4-dimensional hysterosalpingo-contrast sonography with SonoVue for assessing fallopian tube patency.

    Science.gov (United States)

    He, Yanni; Geng, Qiang; Liu, Hongmei; Han, Xiaohua

    2013-07-01

    This study was conducted to describe our first experience using transvaginal 4-dimensional (4D) hysterosalpingo-contrast sonography with SonoVue (Bracco International BV, Amsterdam, the Netherlands) for diagnosis of fallopian tube patency. The study was prospective and conducted in a university hospital setting. The sonographic procedures included 2-dimensional transvaginal sonography for evaluating uterine and ovarian mobility, observing intubation, and determining the initial plane and 4D hysterosalpingo-contrast sonography for observing periovarian and pelvic diffusion. Ninety-six outpatients visiting infertility clinics underwent 4D hysterosalpingo-contrast sonography. All patients finished the examination successfully. A total of 192 fallopian tubes were assessed, of which 95 (49.5%) were classified as type A (the tube was patent, and the contrast agent flowed smoothly through it), 72 (37.5%) as type B (the tube was patent, but the contrast agent did not flow smoothly inside it), and 25 (13.0%) as type C (blocked). Sixteen patients underwent laparoscopy or laparoscopy combined with hysteroscopy; 28 tubes (87.5%) were concordant with laparoscopy. The sensitivity, specificity, positive predictive value, negative predictive value, and Youden index for 4D hysterosalpingo-contrast sonography versus laparoscopy were 81.8%, 90.5%, 81.8%, 90.5%, and 0.72 respectively. In total, 92.7% of patients did not require a hospital stay after 4D hysterosalpingo-contrast sonography, and none need resuscitation. The others stayed in the hospital for clinical observation because of a severe vasovagal reaction or severe pain but received only bed rest without any medical treatment. Forty patients (41.7%) felt slight pain; 39 (40.6%) felt moderate pain; and 15 (15.6%) had a vasovagal reaction. No procedure or postprocedure complications occurred in any patient. In conclusion, 4D hysterosalpingo-contrast sonography with SonoVue is an available screening method for assessment of tubal

  7. The photomultiplier tube testing facility for the Borexino experiment at LNGS

    Energy Technology Data Exchange (ETDEWEB)

    Brigatti, A. [INFN sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Ianni, A. [INFN - Laboratori Nazionali del Gran Sasso, S.S. 17bis Km 18-910, I-67010 Assergi, Aquila (Italy); Lombardi, P. [Dipartimento di Fisica Universita and INFN. sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Ranucci, G. [Dipartimento di Fisica Universita and INFN. sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Smirnov, O.Ju. [Joint Institute for Nuclear Research, Joliot-Curie, 6, 141980 Dubna (Russian Federation)]. E-mail: smirnov@lngs.infn.it

    2005-02-01

    A facility to test the photomultiplier tubes (PMTs) for the solar neutrino detector Borexino was built at the Gran Sasso laboratory. Using the facility 2200 PMTs with optimal characteristics were selected from the 2350 delivered from the manufacturer. The details of the hardware used are presented.

  8. Improvement of Eddy Current testing methods of steam generator tubings due to field experience

    International Nuclear Information System (INIS)

    Comby, R.; Meurgey, P.; David, B.

    1985-01-01

    This paper presents the main stages of the long rotating probe developed by EDF, this probe detects stress corrosion cracks. The method has been validated by the examination of numerous cracked tubes that the probe detected before. Methods to better characterize the signals with regard to the defects are being improved to avoid a complementary examination of the rolling zone more particularly [fr

  9. Numerical study of chemical reactions in a surface microdischarge tube with mist flow based on experiment

    International Nuclear Information System (INIS)

    Shibata, T; Nishiyama, H

    2014-01-01

    Recently, a water treatment method of spraying solution into a discharge region has been developed and shows high energy efficiency. In this study, a simulation model of a water treatment method using a surface microdischarge (SMD) tube with mist flow is proposed for further understanding the detailed chemical reactions. Our model has three phases (plasma, gas and liquid) and three simulation steps. The carrier gas is humid air including 2% or 3% water vapour. The chemical species diffusion characteristics in the SMD tube and the concentrations in a droplet are clarified in a wide pH interval. The simulation results show that the chemical species generated on the SMD tube inner wall are diffused to the central axis and dissolved into fine droplets. Especially, OH radicals dissolve into droplets a few mm away from the SMD tube wall because of acidification of the droplets. Furthermore, the hydrogen peroxide density, which is the most important indicator of a radical reaction in water, is influenced by the initial solution pH. This pH dependence results from ozone self-decomposition in water. (paper)

  10. Numerical study of chemical reactions in a surface microdischarge tube with mist flow based on experiment

    Science.gov (United States)

    Shibata, T.; Nishiyama, H.

    2014-03-01

    Recently, a water treatment method of spraying solution into a discharge region has been developed and shows high energy efficiency. In this study, a simulation model of a water treatment method using a surface microdischarge (SMD) tube with mist flow is proposed for further understanding the detailed chemical reactions. Our model has three phases (plasma, gas and liquid) and three simulation steps. The carrier gas is humid air including 2% or 3% water vapour. The chemical species diffusion characteristics in the SMD tube and the concentrations in a droplet are clarified in a wide pH interval. The simulation results show that the chemical species generated on the SMD tube inner wall are diffused to the central axis and dissolved into fine droplets. Especially, OH radicals dissolve into droplets a few mm away from the SMD tube wall because of acidification of the droplets. Furthermore, the hydrogen peroxide density, which is the most important indicator of a radical reaction in water, is influenced by the initial solution pH. This pH dependence results from ozone self-decomposition in water.

  11. LHCb: Ageing Phenomena in the Straw Tube Tracker (Outer Tracker) of the LHCb experiment

    CERN Multimedia

    Bachmann, S

    2009-01-01

    The outer tracking system of the LHCb spectrometer is built in the straw tube technology. In tota it consists of 53760 straw of 2.5m length. Thorough investigations have been performed to study the detector performance under long-term irradiations. Problems occuring caused by ageing are discussed and solutions are presented.

  12. A condensation experiment in the accumulated conditions of noncondensable gas in a vertical tube

    International Nuclear Information System (INIS)

    Lee, Kwon Yeong; Kim, Moo Hwan

    2005-01-01

    Full text of publication follows: It has been well known that the presence of noncondensable gases in vapors can greatly inhibit the condensation process. Many analytical and experimental studies were conducted to investigate the effect of noncondensable gases on steam condensation for both stagnant and forced-convective situations either over a plate or outside a horizontal tube. Recently, several researches have been performed for the condensation in the presence of noncondensable gases taken place inside the vertical tube in order to give the information to design the passive containment cooling system (PCCS) in Simplified Boiling Water Reactor (SBWR). Generally, the experimental results showed that the heat transfer coefficient depends on inlet noncondensable gas mass fraction, inlet saturated steam temperature related with system pressure and inlet mixture Reynolds number. This research was performed for the System-integrated Modular Advanced ReacTor-Pilot (SMART-P), in which the remaining heat is removed from the core passively by Passive Residual Heat Removal System (PRHRS) condenser in a period of serious accident. The PRHRS is separated from working fluid loop, and pressurized by a nitrogen gas during the normal operation of SMART-P. But when the PRHRS starts operating, the nitrogen gas acts as a noncondensable gas and affects the heat transfer characteristics of the PRHRS. The experimental conditions of this study were almost similar with those of previous researches except the noncondensable gas was accumulated and remained inside the vertical tube. In the previous researches, the noncondensable gas was flowing with constant flow rate. Because of the condensate inside condenser tube, the accumulation of noncondensable gas could be developed inside the vertical tube. At steady-state condition the local temperatures and system pressure were measured to obtain heat transfer characteristics. This study also gave the information about the distribution of the

  13. Modelling of time delay of electrical breakdown for nitrogen-filled tubes at pressures of 6.6 and 13.3 mbar in the increase region of the memory curve

    International Nuclear Information System (INIS)

    Nesic, N T; Ristic, G S; Pejovic, M M; Karamarkovic, J P

    2008-01-01

    Experimentally measured electrical breakdown time delay data versus the afterglow period (representing 'memory curves') for nitrogen-filled tubes at pressures of 6.6 and 13.3 mbar have been shown. The influence of N( 4 S) nitrogen atoms on secondary electron emission from the cathode (the SEE process) in late afterglow has been discussed. N( 4 S) atom concentration decay over relaxation time τ, N( 4 S)(τ), has been analysed by a numerical model and two analytical models. N( 4 S) decay analytical models are combined with different yield models that describe the SEE process by N( 4 S) and these combinations are employed to fit the experimental data. It has been shown that in late afterglow solving of very simple analytical equations instead of numerical solving of partial differential equations for N( 4 S)(τ) fitting can be used and that the combination of the first and the second order of the SEE process by N( 4 S) in yield modelling should be used in the case of 13.3 mbar pressure.

  14. The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator.

    Science.gov (United States)

    White, Donna M; Redondo, José I; Mair, Alastair R; Martinez-Taboada, Fernando

    2017-09-01

    The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator. Prospective, experimental clinical study. Participants included veterinary students at the beginning (group S1) and end (group S2) of their 2-week anaesthesia rotation and veterinary anaesthetists (group A). The feline airway simulator was designed to simulate an average size feline trachea, intubated with a 4.5 mm low-pressure, high-volume cuffed endotracheal tube, connected to a Bain breathing system with oxygen flow of 2 L minute -1 . Participants inflated the on-endotracheal tube cuff by pilot balloon palpation and by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during manual ventilation. Intracuff pressures were measured by manometers obscured to participants and ideally were 20-30 cm H 2 O. Student t, Fisher exact, and Chi-squared tests were used where appropriate to analyse data (p Experience had no effect on this skill and, as such, a cuff manometer is recommended. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  15. Practical experience in the determination of the tube voltage using the Ardran-Crooks cassette

    International Nuclear Information System (INIS)

    Ewen, K.; Roesner, W.

    1984-01-01

    Within the framework of quality control measures in X-ray diagnostics and therapy, it is desirable to employ for the determination of tube voltage (e.g. in diagnostic X-ray equipment) methods which are as economical as possible while saving time and being simple to apply in spite of the fact that they are as highly accurate as ever possible. The absorber method described here, represented by the Ardran-Crooks cassette, possesses the advantage of low price and easy application. However, if it is operated in such a way that time is saved (assessment by the eye), it is not so accurate, whereas in accurate operation (assessment via luxmeter) it does require a relatively large amount of time. After the film has been exposed, it is necessary to estimate or measure the agreement of blackenings on one and the same film in order to determine the tube voltage. This voltage is then read off by means of a calibration curve. The error in the determination of the tube voltage via the Ardran-Crooks cassette depends on the accuracy of the calibration curve, which, in turn, depends on the number of measurements performed when producing the curve, and on the correct voltage of the standard X-ray equipment used in producing the calibration curve. In addition, assessment by eye adds a total error of 2.3% to 8%, depending on the amount of tube voltage. If the luxmeter is used instead of the eye, this additional error is less than 1% in relation to the magnitude of the tube voltage. (orig./BWU) [de

  16. Experiment data report for Semiscale Mod-1 test S-28-3 (steam generator tube rupture test). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Gillins, R.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-3 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-3 was conducted from initial conditions of 15621 kPa and 555 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Twelve steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg.

  17. Experiment data report for Semiscale Mod-1 Test S-28-1 (steam generator tube rupture test series)

    Energy Technology Data Exchange (ETDEWEB)

    Collins, B.L.; Coppin, C.E.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-1 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-1 was conducted from initial conditions of 15 767 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Sixty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg.

  18. Experiment data report for semiscale Mod-1 test S-28-4 (steam generator tube rupture test)

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, V.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-4 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-4 was conducted from initial conditions of 15 646 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Thirty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg.

  19. Experiment data report for Semiscale Mod-1 test S-28-6 (steam generator tube rupture test)

    Energy Technology Data Exchange (ETDEWEB)

    Patton, M.L.; Sackett, K.E.; Coppin, C.E.

    1977-11-01

    Recorded test data are presented for Test S-28-6 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-6 was conducted from initial conditions of 15,770 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Sixteen steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg.

  20. Experiment data report for semiscale Mod-1 test S-28-2 (steam generator tube rupture test). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Patton, M.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-2 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-2 was conducted from initial conditions of 15 936 kPa and 558 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. For Test S-28-2, accumulator injection into the intact loop hot leg was provided to simulate simulate the rupture of six steam generator tubes.

  1. Experiment data report for Semiscale Mod-1 Test S-28-5 (steam generator tube rupture test). [PWR

    Energy Technology Data Exchange (ETDEWEB)

    1977-11-01

    Recorded test data are presented for Test S-28-5 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-5 was conducted from initial conditions of 15,768 kPa and 556 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. For Test S-28-5, accumulator injection into the intact loop hot leg was provided to simulate the rupture of 20 steam generator tubes.

  2. Assessment of RELAP5/MOD3.2 with condensation experiment in the presence of noncondensables in a vertical tube

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; No, Hee Cheon [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    The standard RELAP5/MOD3.2 code were assessed with the condensation experiment in the presence of noncondensable gas in a vertical tube of PCCS of CP-1300. There are two wall film condensation models, the default model and the alternative model, in RELAP5/MOD3.2. The experimental apparatus was modeled with the two models, and simulations were performed for several sub-tests to be compared with the experimental results. In overall sense the simulation results showed that the default model of RELAP5/MOD3.2 under-predicts the heat transfer coefficients, while the alternative model over-predicts them throughout the condensing tube. 10 refs., 6 figs. (Author)

  3. Effects of user experience and method in the inflation of endotracheal tube pilot balloon on cuff pressure.

    Science.gov (United States)

    Ozer, A B; Demirel, I; Gunduz, G; Erhan, O L

    2013-01-01

    Endotracheal tube cuff pressure (ETCP) is recommended to be maintained between 20-30 cm H2O limits. While insufficient inflation of ETC may cause aspirations, over-inflation of it may lead to damage in tracheal epithelium. We planned to investigate the effects of user experience and cuff pressure inflation method differences following endotracheal tube cuff pressure and complaints about it. Two hundred and fifty patients planned for general anaesthesia were included in this study. ETC was inflated by users with different experience according to leakage or pilot balloon palpation techniques. ETCPs were measured by manometer at three periods (5 and 60 minutes after endotracheal intubation, and before extubation). Complaints about it were recorded in post anaesthetic care unit and 24 hours postoperatively. Though we found experience of user had significant effect on the ETCP regulations, we observed inflation methods did not have any effect. However we found ETCP was higher than normal range with experienced users. A correlation was observed between cuff pressure and anaesthesia duration with postoperative complaints. Our study concluded that the methods used do not have any significant advantage over one another. While ETC inflated at normal pressure increases as user's experience increases, experience alone is not enough in adjusting ETCP. A manometer should be used in routine inflation of ETC instead of conventional methods. CP and anaesthesia duration have correlations with some postoperative complaints.

  4. Characteristics and theory of operation of the controlatron neutron tube

    International Nuclear Information System (INIS)

    Volk, R.D.

    1977-01-01

    The Controlatron (or Type 26E) neutron tube was developed by General Electric under contract to Sandia Laboratories in 1961 to be used in a neutron activation analysis experiment on the lunar surface. It was subsequently employed as a very stable laboratory neutron source for neutron detector calibration within the ERDA complex. The Controlatron is a gas filled neutron tube using a titanium target, Penning type cold cathode ion source, and self-contained reservoir. The general theory of operation of this type of neutron tube utilizing the D-T nuclear reaction is presented

  5. Experience in quality assurance of alloy D9 clad tubes for Prototype Fast Breeder Reactor

    International Nuclear Information System (INIS)

    Kapoor, K.; Prahlad, B.

    2012-01-01

    Stainless Steel Alloy D9 is the material for cladding in various sub-assemblies of Prototype Fast Breeder Reactor (PFBR). The fabrication, inspection, testing and supply of the clad tubes for the first core of PFBR is nearly completed. The paper also compares the specification requirements and the achieved results for some of the critical aspects which is arrived after completing supply against the first core requirement

  6. Prevention of neural tube defects with folic acid: The Chinese experience.

    Science.gov (United States)

    Ren, Ai-Guo

    2015-08-08

    Neural tube defects (NTDs) are a group of congenital malformations of the central nervous system that are caused by the closure failure of the embryonic neural tube by the 28(th) day of conception. Anencephaly and spina bifida are the two major subtypes. Fetuses with anencephaly are often stillborn or electively aborted due to prenatal diagnosis, or they die shortly after birth. Most infants with spina bifida are live-born and, with proper surgical treatment, can survive into adulthood. However, these children often have life-long physical disabilities. China has one of the highest prevalence of NTDs in the world. Inadequate dietary folate intake is believed to be the main cause of the cluster. Unlike many other countries that use staple fortification with folic acid as the public health strategy to prevent NTDs, the Chinese government provides all women who have a rural household registration and who plan to become pregnant with folic acid supplements, free of charge, through a nation-wide program started in 2009. Two to three years after the initiation of the program, the folic acid supplementation rate increased to 85% in the areas of the highest NTD prevalence. The mean plasma folate level of women during early and mid-pregnancy doubled the level before the program was introduced. However, most women began taking folic acid supplements when they knew that they were pregnant. This is too late for the protection of the embryonic neural tube. In a post-program survey of the women who reported folic acid supplementation, less than a quarter of the women began taking supplements prior to pregnancy, indicating that the remaining three quarters of the fetuses remained unprotected during the time of neural tube formation. Therefore, staple food fortification with folic acid should be considered as a priority in the prevention of NTDs.

  7. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mendler, O J; Takeuchi, K; Young, M Y

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results.

  8. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    International Nuclear Information System (INIS)

    Mendler, O.J.; Takeuchi, K.; Young, M.Y.

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results

  9. A measurement of radiation output from X- ray tubes: AIIMS experience

    International Nuclear Information System (INIS)

    Karan, R.; Bahl, Shaila; Thulkar, S.; Kumar, Pratik

    2016-01-01

    The production of x-rays is a relatively inefficient process so that only a small fraction of the energy imparted by the decelerating electrons is converted into X-rays. The remaining energy is converted to heat. Thus, the production and dissipation of heat in the X-ray tube is a serious consideration. Quality control is a system of routine technical activities, to measure and control the quality of the inventory as it is being developed. This paper aims to study the X-ray tube output of the Digital flat panel Detector X-ray (Aristos MX) Unit. The radiation output of the tube was being monitored for duration of 1 year from July 2011 to June 2012 for two different KVp and mAs namely 81 KVp, 125 mAs and 60 KVp, 100mAs. The results obtained were plotted with the intensity of X-ray output obtained with respect to months and the results were analyzed. (author)

  10. On the mechanism of flow evolution in shock-tube experiments

    Science.gov (United States)

    Kiverin, Alexey; Yakovenko, Ivan

    2018-02-01

    The paper studies numerically the flow development behind the shock wave propagating inside the tube. The detailed analysis of the flow patterns behind the shock wave allows determination of the gas-dynamical origins of the temperature non-uniformities responsible for the subsequent localized start of chemical reactions in the test mixture. In particular, it is shown that the temperature field structure is determined mainly by the mechanisms of boundary layer instability development. The kinetic energy dissipation related to the flow deceleration inside boundary layer results in local heating of the test gas. At the same time, the heat losses to the tube wall lead to the cooling of the gas. Therefore the temperature stratification takes place on the scales of the boundary layer. As soon as the shock wave reflected from the end-wall of the tube interacts with the developed boundary layer the localized hot regions arise at a certain distance from the end wall. The position of these hot regions is associated with the zones of shock wave interaction with roller vortices at the margin between the boundary layer and the bulk flow. Formulated mechanism of the temperature field evolution can be used to explain the peculiarities of non-steady shock-induced ignition of combustible mixtures with moderate ignition delay times, where the ignition starts inside localized kernels at distance from the end wall.

  11. Timing calibration of the trigger system for the drift tube detector of the OPERA neutrino oscillation experiment

    International Nuclear Information System (INIS)

    Lenkeit, Jan

    2015-11-01

    The OPERA experiment searches for ν μ → ν τ oscillations in an almost pure ν μ beam. The goal is to observe the oscillations in appearance mode by using a large-scale lead/emulsion target to resolve individual ν τ interactions. Magnetic spectrometers measure the charge and momentum of beam induced muons leaving the target sections. The Precision Tracker, a drift tube detector consisting of almost 10000 drift tubes, provides the tracking information inside the spectrometers. The coordinate measurement in the drift tubes is derived from a time measurement relative to an external trigger signal. In order to reach the required momentum resolution of less than 25 % for particle momenta up to 25 GeV, the uncertainty on the trigger timing must not exceed a value of 5 ns. In this thesis, a procedure for the timing calibration of the trigger system is presented. A step-by-step calibration of the corresponding signal paths is described. Applying all calibration results, a spatial resolution of 255 μm is achieved for the Precision Tracker, meeting the specified requirements. Furthermore, a method using the calibrated trigger system for performing time of flight measurements with atmospheric muons is developed. The average error on the measured flight times is ±4.5 ns.

  12. Development of a dedicated front-end electronics for straw tube trackers in the bar PANDA experiment

    Science.gov (United States)

    Przyborowski, D.; Fiutowski, T.; Idzik, M.; Kajetanowicz, M.; Korcyl, G.; Salabura, P.; Smyrski, J.; Strzempek, P.; Swientek, K.; Terlecki, P.; Tokarz, J.

    2016-08-01

    The design and tests of front-end electronics for straw tube trackers in the bar PANDA experiment at FAIR are presented. The challenges for the front-end electronics, comprising operation at high counting rate up to 1 MHz per straw tube, are discussed and the proposed architecture comprising a switched gain charge sensitive preamplifier (CSP), a pole-zero cancellation circuit (PZC), a second order variable peaking time shaper, a trimming ion tail cancellation circuit, and a baseline holder (BLH), is described. The front-end provides an analogue output and a discriminator with LVDS differential driver for the Time-of-Arrival (ToA) and Time-over-Threshold (ToT) measurements. A prototype readout ASIC featuring four channels was fabricated in 0.35 μm CMOS technology consuming 15.5 mW (analog part) and 12 mW (LVDS) per channel. The results of measurements of peaking time (25-67 ns), gain, noise (ENC 800-2500 el. for various gains), time walk and jitter are presented as well as the first results obtained with prototype straw tubes connected.

  13. Naturally Occurring Peer Support through Social Media: The Experiences of Individuals with Severe Mental Illness Using YouTube

    Science.gov (United States)

    Naslund, John A.; Grande, Stuart W.; Aschbrenner, Kelly A.; Elwyn, Glyn

    2014-01-01

    Increasingly, people with diverse health conditions turn to social media to share their illness experiences or seek advice from others with similar health concerns. This unstructured medium may represent a platform on which individuals with severe mental illness naturally provide and receive peer support. Peer support includes a system of mutual giving and receiving where individuals with severe mental illness can offer hope, companionship, and encouragement to others facing similar challenges. In this study we explore the phenomenon of individuals with severe mental illness uploading videos to YouTube, and posting and responding to comments as a form of naturally occurring peer support. We also consider the potential risks and benefits of self-disclosure and interacting with others on YouTube. To address these questions, we used qualitative inquiry informed by emerging techniques in online ethnography. We analyzed n = 3,044 comments posted to 19 videos uploaded by individuals who self-identified as having schizophrenia, schizoaffective disorder, or bipolar disorder. We found peer support across four themes: minimizing a sense of isolation and providing hope; finding support through peer exchange and reciprocity; sharing strategies for coping with day-to-day challenges of severe mental illness; and learning from shared experiences of medication use and seeking mental health care. These broad themes are consistent with accepted notions of peer support in severe mental illness as a voluntary process aimed at inclusion and mutual advancement through shared experience and developing a sense of community. Our data suggest that the lack of anonymity and associated risks of being identified as an individual with severe mental illness on YouTube seem to be overlooked by those who posted comments or uploaded videos. Whether or not this platform can provide benefits for a wider community of individuals with severe mental illness remains uncertain. PMID:25333470

  14. Naturally occurring peer support through social media: the experiences of individuals with severe mental illness using YouTube.

    Directory of Open Access Journals (Sweden)

    John A Naslund

    Full Text Available Increasingly, people with diverse health conditions turn to social media to share their illness experiences or seek advice from others with similar health concerns. This unstructured medium may represent a platform on which individuals with severe mental illness naturally provide and receive peer support. Peer support includes a system of mutual giving and receiving where individuals with severe mental illness can offer hope, companionship, and encouragement to others facing similar challenges. In this study we explore the phenomenon of individuals with severe mental illness uploading videos to YouTube, and posting and responding to comments as a form of naturally occurring peer support. We also consider the potential risks and benefits of self-disclosure and interacting with others on YouTube. To address these questions, we used qualitative inquiry informed by emerging techniques in online ethnography. We analyzed n = 3,044 comments posted to 19 videos uploaded by individuals who self-identified as having schizophrenia, schizoaffective disorder, or bipolar disorder. We found peer support across four themes: minimizing a sense of isolation and providing hope; finding support through peer exchange and reciprocity; sharing strategies for coping with day-to-day challenges of severe mental illness; and learning from shared experiences of medication use and seeking mental health care. These broad themes are consistent with accepted notions of peer support in severe mental illness as a voluntary process aimed at inclusion and mutual advancement through shared experience and developing a sense of community. Our data suggest that the lack of anonymity and associated risks of being identified as an individual with severe mental illness on YouTube seem to be overlooked by those who posted comments or uploaded videos. Whether or not this platform can provide benefits for a wider community of individuals with severe mental illness remains uncertain.

  15. Naturally occurring peer support through social media: the experiences of individuals with severe mental illness using YouTube.

    Science.gov (United States)

    Naslund, John A; Grande, Stuart W; Aschbrenner, Kelly A; Elwyn, Glyn

    2014-01-01

    Increasingly, people with diverse health conditions turn to social media to share their illness experiences or seek advice from others with similar health concerns. This unstructured medium may represent a platform on which individuals with severe mental illness naturally provide and receive peer support. Peer support includes a system of mutual giving and receiving where individuals with severe mental illness can offer hope, companionship, and encouragement to others facing similar challenges. In this study we explore the phenomenon of individuals with severe mental illness uploading videos to YouTube, and posting and responding to comments as a form of naturally occurring peer support. We also consider the potential risks and benefits of self-disclosure and interacting with others on YouTube. To address these questions, we used qualitative inquiry informed by emerging techniques in online ethnography. We analyzed n = 3,044 comments posted to 19 videos uploaded by individuals who self-identified as having schizophrenia, schizoaffective disorder, or bipolar disorder. We found peer support across four themes: minimizing a sense of isolation and providing hope; finding support through peer exchange and reciprocity; sharing strategies for coping with day-to-day challenges of severe mental illness; and learning from shared experiences of medication use and seeking mental health care. These broad themes are consistent with accepted notions of peer support in severe mental illness as a voluntary process aimed at inclusion and mutual advancement through shared experience and developing a sense of community. Our data suggest that the lack of anonymity and associated risks of being identified as an individual with severe mental illness on YouTube seem to be overlooked by those who posted comments or uploaded videos. Whether or not this platform can provide benefits for a wider community of individuals with severe mental illness remains uncertain.

  16. Critical heat flux experiments in a circular tube with heavy water and light water. (AWBA Development Program)

    International Nuclear Information System (INIS)

    Williams, C.L.; Beus, S.G.

    1980-05-01

    Experiments were performed to establish the critical heat flux (CHF) characteristics of heavy water and light water. Testing was performed with the up-flow of heavy and of light water within a 0.3744 inch inside diameter circular tube with 72.3 inches of heated length. Comparisons were made between heavy water and light water critical heat flux levels for the same local equilibrium quality at CHF, operating pressure, and nominal mass velocity. Results showed that heavy water CHF values were, on the average, 8 percent below the light water CHF values

  17. Nasogastric and feeding tubes.

    Science.gov (United States)

    Gharib, Ahmed M; Stern, Eric J; Sherbin, Vandy L; Rohrmann, Charles A

    1996-05-01

    Preview The authors' experience in a radiology department suggested to them that there is a wide range of beliefs among practitioners regarding proper placement of nasogastric and feeding tubes. Improper positioning can cause serious problems, as they explain. Indications for different tube positions, complications of incorrect tube placement, and directions for proper positioning are discussed and illustrated.

  18. Steam condensation induced water hammer in a vertical up-fill configuration within an integral test facility. Experiments and computational simulations

    Energy Technology Data Exchange (ETDEWEB)

    Dirndorfer, Stefan

    2017-01-17

    Condensation induced water hammer is a source of danger and unpredictable loads in pipe systems. Studies concerning condensation induced water hammer were predominantly made for horizontal pipes, studies concerning vertical pipe geometries are quite rare. This work presents a new integral test facility and an analysis of condensation induced water hammer in a vertical up-fill configuration. Thanks to the state of the art technology, the phenomenology of vertical condensation induced water hammer can be analysed by means of sufficient high-sampled experimental data. The system code ATHLET is used to simulate UniBw condensation induced water hammer experiments. A newly developed and implemented direct contact condensation model enables ATHLET to calculate condensation induced water hammer. Selected experiments are validated by the modified ATHLET system code. A sensitivity analysis in ATHLET, together with the experimental data, allows to assess the performance of ATHLET to compute condensation induced water hammer in a vertical up-fill configuration.

  19. Steam condensation induced water hammer in a vertical up-fill configuration within an integral test facility. Experiments and computational simulations

    International Nuclear Information System (INIS)

    Dirndorfer, Stefan

    2017-01-01

    Condensation induced water hammer is a source of danger and unpredictable loads in pipe systems. Studies concerning condensation induced water hammer were predominantly made for horizontal pipes, studies concerning vertical pipe geometries are quite rare. This work presents a new integral test facility and an analysis of condensation induced water hammer in a vertical up-fill configuration. Thanks to the state of the art technology, the phenomenology of vertical condensation induced water hammer can be analysed by means of sufficient high-sampled experimental data. The system code ATHLET is used to simulate UniBw condensation induced water hammer experiments. A newly developed and implemented direct contact condensation model enables ATHLET to calculate condensation induced water hammer. Selected experiments are validated by the modified ATHLET system code. A sensitivity analysis in ATHLET, together with the experimental data, allows to assess the performance of ATHLET to compute condensation induced water hammer in a vertical up-fill configuration.

  20. Prenatal paradox: an integrative review of women's experiences with prenatal screening for fetal aneuploidy and neural tube defects.

    Science.gov (United States)

    Shea, Tamra L

    2017-04-01

    As prenatal screening for fetal aneuploidy and neural tube defects evolves technologically and becomes increasingly utilized worldwide, an evaluation of the available evidence on women's experiences with prenatal screening is warranted. To conduct an integrative review to enhance understanding of women's experiences with prenatal screening for fetal aneuploidy and neural tube defects. Systematic literature searches from January 2005 through January 2016, using the CINAHL, PubMed, and PsychInfo electronic databases and ancestry searches of included studies were performed to identify previously published, peer-reviewed quantitative and qualitative studies. The integrative review method as proposed by Whittemore and Knafl was selected. Thirty-nine studies were included in the review. The literature reveals that prenatal screening occurs in a complex social, ethical, and political reality. A theme of paradox emerged indicating the incongruity between reported and perceived risk, the tension between informational utility and moral decisions concerning pregnancy management, and the pervasive influences of authoritative and experiential knowledge. There is a need for future inquiry to critically examine the interrelationships of individual, biomedical, ethical, and sociopolitical factors surrounding prenatal screening.

  1. Operational experience in the Langley expansion tube with various test gases. [for atmospheric entry simulation

    Science.gov (United States)

    Miller, C. G.

    1977-01-01

    The Langley Expansion Tube is an operational facility capable of producing good quality, highly repeatable, quasi-steady flow for test times sufficient to establish flow about blunt axisymmetric and two-dimensional models. Due to the capability of testing with arbitrary test gases, a wide range of real-gas, hypersonic-hypervelocity flow conditions may be generated. However, for a given test gas, the range of operating conditions producing useful flow is shown to be rather limited; hence, the facility yields a given flow condition for a given test gas, and variation in flow conditions comes about by using different test gases. Data are presented for operations using air and carbon dioxide as test gases. The driver gas was unheated helium at a nominal pressure of 5000 psi (34.5 MN sq m).

  2. Assessment of RELAP5/MOD3 with condensation experiment for pure steam condensation in a vercal tube

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Jae; No, Hee Cheon [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    The film condensation models in RELAP5/MOD3.1 and RELAP5/MOD3.2 are assessed with the data of experiment performed in the scaled down condensation experimental facility with a single vertical tube of inner diameter of 46 mm in the range of pressure 0.1 {approx} 7.5 MPa for the PSCS(Passive Secondary Condenser System). Both MOD3.1 and MOD3.2 don`t shows any reliable predictions of the experimental data. The RELAP5/MOD3.1 overpredicts the heat transfer coefficients of experiment, whereas the RELAP5/MOD3.2 underpredicts those data. It is recommended that the film condensation model in RELAP5/MOD3.2 should be modified to have a larger heat transfer coefficient than those of the present model to give the reliable predictions. 7 refs., 6 figs., 1 tab. (Author)

  3. Results from MARBLE DT Experiments on the National Ignition Facility: Implosion of Foam-Filled Capsules for Studying Thermonuclear Burn in the Presence of Heterogeneous Mix

    Science.gov (United States)

    Murphy, T. J.; Douglas, M. R.; Cardenas, T.; Cooley, J. H.; Gunderson, M. A.; Haines, B. M.; Hamilton, C. E.; Kim, Y.; Lee, M. N.; Oertel, J. A.; Olson, R. E.; Randolph, R. B.; Shah, R. C.; Smidt, J. M.

    2017-10-01

    The MARBLE campaign on NIF investigates the effect of heterogeneous mix on thermonuclear burn for comparison to a probability distribution function (PDF) burn model. MARBLE utilizes plastic capsules filled with deuterated plastic foam and tritium gas. The ratio of DT to DD neutron yield is indicative of the degree to which the foam and the gas atomically mix. Platform development experiments have been performed to understand the behavior of the foam and of the gas separately using two types of capsule. The first experiments using deuterated foam and tritium gas have been performed. Results of these experiments, and the implications for our understanding of thermonuclear burn in heterogeneously mixed separated reactant experiments will be discussed. This work is supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.

  4. Paramedic Intubation Experience Is Associated With Successful Tube Placement but Not Cardiac Arrest Survival.

    Science.gov (United States)

    Dyson, Kylie; Bray, Janet E; Smith, Karen; Bernard, Stephen; Straney, Lahn; Nair, Resmi; Finn, Judith

    2017-09-01

    Paramedic experience with intubation may be an important factor in skill performance and patient outcomes. Our objective is to examine the association between previous intubation experience and successful intubation. In a subcohort of out-of-hospital cardiac arrest cases, we also measure the association between patient survival and previous paramedic intubation experience. We analyzed data from Ambulance Victoria electronic patient care records and the Victorian Ambulance Cardiac Arrest Registry for January 1, 2008, to September 26, 2014. For each patient case, we defined intubation experience as the number of intubations attempted by each paramedic in the previous 3 years. Using logistic regression, we estimated the association between intubation experience and (1) successful intubation and (2) first-pass success. In the out-of-hospital cardiac arrest cohort, we determined the association between previous intubation experience and patient survival. During the 6.7-year study period, 769 paramedics attempted intubation in 14,857 patients. Paramedics typically performed 3 intubations per year (interquartile range 1 to 6). Most intubations were successful (95%), including 80% on the first attempt. Previous intubation experience was associated with intubation success (odds ratio 1.04; 95% confidence interval 1.03 to 1.05) and intubation first-pass success (odds ratio 1.02; 95% confidence interval 1.01 to 1.03). In the out-of-hospital cardiac arrest subcohort (n=9,751), paramedic intubation experience was not associated with patient survival. Paramedics in this Australian cohort performed few intubations. Previous experience was associated with successful intubation. Among out-of-hospital cardiac arrest patients for whom intubation was attempted, previous paramedic intubation experience was not associated with patient survival. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  5. Large-scale heat transfer experiments with supercritical R134a flowing upward in a circular tube

    Energy Technology Data Exchange (ETDEWEB)

    Feuerstein, Florian; Coelho Silva, Alexandre; Klingel, Denis; Cheng, Xu [KIT Karlsruhe Institute of Technology (Germany). Inst. of Fusion and Reactor Technology

    2017-02-15

    Heat transfer experiments with supercritical Freon R134a flowing upward in a circular tube with inner diameter of 10 mm and a heating length of 2,495 mm were conducted with a wide range of parameters: mass fluxes of 300 to 2,000 kg/m2s, heat fluxes of 10 to 200 kW/m2, bulk fluid temperature of 50 to 124 C and pressures of 4.22 to 5.51 MPa. Effects of heat flux, mass flux, pressure and inlet temperature on heat transfer behavior are analyzed. Significant heat transfer deterioration is observed above a critical heat flux to mass flux ratio. Six representative correlations were selected and compared with the test data.

  6. Corrosion in PWR steam generator tubes made of alloy 600TT: overview of operating experience, NDE and safety issues

    International Nuclear Information System (INIS)

    Curieres, I. de; Sollier, T.; Delaval, C.

    2015-01-01

    About 60 PWR plants worldwide are operating with steam generator tubes made of alloy 600TT, among which 27 are located in France. This alloy is susceptible to corrosion, both on the primary and secondary side in every fleet, though with different kinetics or extent. It is noteworthy that many of the primary side corrosion issues can be clearly explained by design or operating conditions. However, studies show that all the secondary side issues are much hardly explained by simple considerations. This paper will give an overview of the international operating experience of this alloy and indicate the associated controllability and safety-related issues. An emphasis will be put on the manufacturing, chemistry and specificities of the different fleets. The French situation will be reviewed in this frame. (authors)

  7. Framatome experience and programs in relation to guide tube support pin cracking

    International Nuclear Information System (INIS)

    Benhamou, C.; Poitrenaud, P.

    1989-01-01

    Guide tube support pins installed in the upper internals of pressurized water reactors (PWR) have failed by stress corrosion cracking (SCC). Typical pin crack locations are in the first thread area, shank-to-shoulder transition, and at the end of the leaves. The support pins were made of Inconel X-750 with a solution treatment between 885 degree C (1625 degree F) and 1150 degree C (2100 degree F), followed by a single or double aging, depending on the material supplier. EDF and Framatome initiated an extensive program to address the concern for the potential of support pin cracking in 21 operating units. Short-term actions identified the cause of cracking as a combination of inherent high design stress and a material susceptible to stress corrosion cracking. Long-range objectives are to determine the relation between metallurgy and SCC resistance and to decrease the operating stress. Second-generation design improvements to increase SCC resistance included a revised heat treatment of solution annealing at 1093 degree C (2000 degree F) followed by aging at 704 degree C (1300 degree F), and use of a parabolic radius in the shank/shoulder area, and decreasing the installation torque. Third generation changes included an improved torquing procedure, polishing of crack-sensitive areas, and tighter dimensional control. Fourth-generation pin modifications required the use of Inconel X-750 water quenched from the solution-annealing temperature to improve resistance to SCC with thread rolling after aging. Stress corrosion cracking tests of Inconel X-750, 718, and A286 in a PWR environment were performed. Smooth tensile data on Inconel X-750 with the second-generation heat treatment allowed a life prediction of 80,000 hours or 11 years for a stress level about yield strength. The effect of grain size, grain boundary phases, and precipitate morphology on resistance to stress corrosion cracking were also evaluated

  8. Optimal Bayesian experimental design for priors of compact support with application to shock-tube experiments for combustion kinetics

    KAUST Repository

    Bisetti, Fabrizio

    2016-01-12

    The analysis of reactive systems in combustion science and technology relies on detailed models comprising many chemical reactions that describe the conversion of fuel and oxidizer into products and the formation of pollutants. Shock-tube experiments are a convenient setting for measuring the rate parameters of individual reactions. The temperature, pressure, and concentration of reactants are chosen to maximize the sensitivity of the measured quantities to the rate parameter of the target reaction. In this study, we optimize the experimental setup computationally by optimal experimental design (OED) in a Bayesian framework. We approximate the posterior probability density functions (pdf) using truncated Gaussian distributions in order to account for the bounded domain of the uniform prior pdf of the parameters. The underlying Gaussian distribution is obtained in the spirit of the Laplace method, more precisely, the mode is chosen as the maximum a posteriori (MAP) estimate, and the covariance is chosen as the negative inverse of the Hessian of the misfit function at the MAP estimate. The model related entities are obtained from a polynomial surrogate. The optimality, quantified by the information gain measures, can be estimated efficiently by a rejection sampling algorithm against the underlying Gaussian probability distribution, rather than against the true posterior. This approach offers a significant error reduction when the magnitude of the invariants of the posterior covariance are comparable to the size of the bounded domain of the prior. We demonstrate the accuracy and superior computational efficiency of our method for shock-tube experiments aiming to measure the model parameters of a key reaction which is part of the complex kinetic network describing the hydrocarbon oxidation. In the experiments, the initial temperature and fuel concentration are optimized with respect to the expected information gain in the estimation of the parameters of the target

  9. Gas-Induced Rectified Motion of a Solid Object in a Liquid-Filled Housing during Vibration: Analysis and Experiments

    Science.gov (United States)

    Torczynski, J. R.; O'Hern, T. J.; Clausen, J. R.; Koehler, T. P.

    2017-11-01

    The motion of a solid object (a piston) that fits closely within a housing filled with viscous liquid is studied. If a small amount of gas is introduced and the system is subjected to axial vibration, then the piston exhibits rectified motion when the drag on the piston depends on its position within the housing. An idealized system, in which the piston is suspended freely between two springs and the gas is replaced with two compressible bellows, is analyzed theoretically and studied experimentally. For a given vibration amplitude or frequency, the piston either remains near its original position (``up'') or moves to a different position (``down''), where its spring suspension is compressed. Analytical and experimental regime maps of the amplitudes and frequencies at which the piston is up or down are in good agreement. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  10. Colloid-Facilitated Transport of 137Cs in Fracture-Fill Material. Experiments and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Dittrich, Timothy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-29

    In this study, we demonstrate how a combination of batch sorption/desorption experiments and column transport experiments were used to effectively parameterize a model describing the colloid-facilitated transport of Cs in the Grimsel granodiorite/FFM system. Cs partition coefficient estimates onto both the colloids and the stationary media obtained from the batch experiments were used as initial estimates of partition coefficients in the column experiments, and then the column experiment results were used to obtain refined estimates of the number of different sorption sites and the adsorption and desorption rate constants of the sites. The desorption portion of the column breakthrough curves highlighted the importance of accounting for adsorption-desorption hysteresis (or a very nonlinear adsorption isotherm) of the Cs on the FFM in the model, and this portion of the breakthrough curves also dictated that there be at least two different types of sorption sites on the FFM. In the end, the two-site model parameters estimated from the column experiments provided excellent matches to the batch adsorption/desorption data, which provided a measure of assurance in the validity of the model.

  11. Nasotracheal tube wire support: a safety device in maxillofacial surgery technical note after five years of experience

    OpenAIRE

    Elias, Fernando Melhem; Sato, F?bio Ricardo Loureiro; Ferraz, Fl?vio Wellington da Silva

    2014-01-01

    A well fixed endotracheal tube is essential for safety during general anesthesia. In maxillofacial surgeries, securely fixing a nasotracheal tube in place has always been problematic. The aim of this article is to describe a simple but effective technique to fasten the nasotracheal tube using a wire support that allows a full range of head movement without interference in the surgical field. During the last 5 years, this device was successfully used in almost two hundred patients with very fe...

  12. Feeding Tubes

    Science.gov (United States)

    ... the TPN. Tubes Used for Enteral Feeds NG (Nasogastric Tube) A flexible tube is placed via the nose, ... portion of the small intestine Naso – nose NG – Nasogastric Tube -ostomy – new opening Percutaneous – through the skin PEJ – ...

  13. Tritium permeation experiments using reduced activation ferritic/martensitic steel tube and erbium oxide coating

    Energy Technology Data Exchange (ETDEWEB)

    Takumi Chikada; Masashi Shimada; Robert Pawelko; Takayuki Terai; Takeo Muroga

    2013-09-01

    Low concentration tritium permeation experiments have been performed on uncoated F82H and Er2O3-coated tubular samples in the framework of the Japan-US TITAN collaborative program. Tritium permeability of the uncoated sample with 1.2 ppm tritium showed one order of magnitude lower than that with 100% deuterium. The permeability of the sample with 40 ppm tritium was more than twice higher than that of 1.2 ppm, indicating a surface contribution at the lower tritium concentration. The Er2O3-coated sample showed two orders of magnitude lower permeability than the uncoated sample, and lower permeability than that of the coated plate sample with 100% deuterium. It was also indicated that the memory effect of ion chambers in the primary and secondary circuits was caused by absorption of tritiated water vapor that was generated by isotope exchange reactions between tritium and surface water on the coating.

  14. Kennedy Space Center Fixation Tube (KFT)

    Science.gov (United States)

    Richards, Stephanie E.; Levine, Howard G.; Romero, Vergel

    2016-01-01

    Experiments performed on the International Space Station (ISS) frequently require the experimental organisms to be preserved until they can be returned to earth for analysis in the appropriate laboratory facility. The Kennedy Fixation Tube (KFT) was developed to allow astronauts to apply fixative, chemical compounds that are often toxic, to biological samples without the use of a glovebox while maintaining three levels of containment (Fig. 1). KFTs have been used over 200 times on-orbit with no leaks of chemical fixative. The KFT is composed of the following elements: a polycarbonate main tube where the fixative is loaded preflight, the sample tube where the plant or other biological specimens is placed during operations, the expansion plug, actuator, and base plug that provides fixative containment (Fig. 2). The main tube is pre-filled with 25 mL of fixative solution prior to flight. When actuated, the specimen contained within the sample tube is immersed with approximately 22 mL (+/- 2 mL) of the fixative solution. The KFT has been demonstrated to maintain its containment at ambient temperatures, 4degC refrigeration and -100 C freezing conditions.

  15. Technical note: Influence of surface roughness and local turbulence on coated-wall flow tube experiments for gas uptake and kinetic studies

    Directory of Open Access Journals (Sweden)

    G. Li

    2018-02-01

    Full Text Available Coated-wall flow tube reactors are frequently used to investigate gas uptake and heterogeneous or multiphase reaction kinetics under laminar flow conditions. Coating surface roughness may potentially distort the laminar flow pattern, induce turbulence and introduce uncertainties in the calculated uptake coefficient based on molecular diffusion assumptions (e.g., Brown/Cooney–Kim–Davis (CKD/Knopf–Pöschl–Shiraiwa (KPS methods, which has not been fully resolved in earlier studies. Here, we investigate the influence of surface roughness and local turbulence on coated-wall flow tube experiments for gas uptake and kinetic studies. According to laminar boundary theory and considering the specific flow conditions in a coated-wall flow tube, we derive and propose a critical height δc to evaluate turbulence effects in the design and analysis of coated-wall flow tube experiments. If a geometric coating thickness δg is larger than δc, the roughness elements of the coating may cause local turbulence and result in overestimation of the real uptake coefficient (γ. We further develop modified CKD/KPS methods (i.e., CKD-LT/KPS-LT to account for roughness-induced local turbulence effects. By combination of the original methods and their modified versions, the maximum error range of γCKD (derived with the CKD method or γKPS (derived with the KPS method can be quantified and finally γ can be constrained. When turbulence is generated, γCKD or γKPS can bear large difference compared to γ. Their difference becomes smaller for gas reactants with lower uptake (i.e., smaller γ and/or for a smaller ratio of the geometric coating thickness to the flow tube radius (δg ∕ R0. On the other hand, the critical height δc can also be adjusted by optimizing flow tube configurations and operating conditions (i.e., tube diameter, length, and flow velocity, to ensure not only unaffected laminar flow patterns but also other specific requirements for an

  16. Technical note: Influence of surface roughness and local turbulence on coated-wall flow tube experiments for gas uptake and kinetic studies

    Science.gov (United States)

    Li, Guo; Su, Hang; Kuhn, Uwe; Meusel, Hannah; Ammann, Markus; Shao, Min; Pöschl, Ulrich; Cheng, Yafang

    2018-02-01

    Coated-wall flow tube reactors are frequently used to investigate gas uptake and heterogeneous or multiphase reaction kinetics under laminar flow conditions. Coating surface roughness may potentially distort the laminar flow pattern, induce turbulence and introduce uncertainties in the calculated uptake coefficient based on molecular diffusion assumptions (e.g., Brown/Cooney-Kim-Davis (CKD)/Knopf-Pöschl-Shiraiwa (KPS) methods), which has not been fully resolved in earlier studies. Here, we investigate the influence of surface roughness and local turbulence on coated-wall flow tube experiments for gas uptake and kinetic studies. According to laminar boundary theory and considering the specific flow conditions in a coated-wall flow tube, we derive and propose a critical height δc to evaluate turbulence effects in the design and analysis of coated-wall flow tube experiments. If a geometric coating thickness δg is larger than δc, the roughness elements of the coating may cause local turbulence and result in overestimation of the real uptake coefficient (γ). We further develop modified CKD/KPS methods (i.e., CKD-LT/KPS-LT) to account for roughness-induced local turbulence effects. By combination of the original methods and their modified versions, the maximum error range of γCKD (derived with the CKD method) or γKPS (derived with the KPS method) can be quantified and finally γ can be constrained. When turbulence is generated, γCKD or γKPS can bear large difference compared to γ. Their difference becomes smaller for gas reactants with lower uptake (i.e., smaller γ) and/or for a smaller ratio of the geometric coating thickness to the flow tube radius (δg / R0). On the other hand, the critical height δc can also be adjusted by optimizing flow tube configurations and operating conditions (i.e., tube diameter, length, and flow velocity), to ensure not only unaffected laminar flow patterns but also other specific requirements for an individual flow tube

  17. Americium, Cesium, and Plutonium Colloid-Facilitated Transport in a Groundwater/Bentonite/Fracture Fill Material System: Column Experiments and Model Results

    Science.gov (United States)

    Dittrich, T. M.; Boukhalfa, H.; Reimus, P. W.

    2014-12-01

    The objective of this study was to investigate and quantify the effects of desorption kinetics and colloid transport on radionuclides with different sorption affinities. We focused on quantifying transport mechanisms important for upscaling in time and distance. This will help determine the long-term fate and transport of radionuclides to aid in risk assessments. We selected a fractured/weathered granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model crystalline rock repository system because the system has been thoroughly studied and field experiments involving radionuclides have already been conducted. Working on this system provides a unique opportunity to compare lab experiments with field-scale observations. Weathered fracture fill material (FFM) and bentonite used as backfill at the GTS were characterized (e.g., BET, SEM/EDS, QXRD), and batch and breakthrough column experiments were conducted. Solutions were prepared in synthetic groundwaters that matched the natural water chemistry. FFM samples were crushed, rinsed, sieved (150-355 μm), and equilibrated with synthetic groundwater. Bentonite was crushed, sodium-saturated, equilibrated with synthetic groundwater, and settled to yield a stable suspension. Suspensions were equilibrated with Am, Cs, or Pu. All experiments were conducted with Teflon®materials to limit sorption to system components. After radionuclide/colloid injections reached stability, radionuclide-free solutions were injected to observe the desorption and release behavior. Aliquots of effluent were measured for pH, colloid concentration, and total and dissolved radionuclides. Unanalyzed effluent from the first column was then injected through a second column of fresh material. The process was repeated for a third column and the results of all three breakthrough curves were modeled with a multi-site/multi-rate MATLAB code to elucidate the sorption rate coefficients and binding site densities of the bentonite colloids and

  18. Assembly and operation experience of EVA II steam reforming bundle

    International Nuclear Information System (INIS)

    Niessen, H.F.; Harth, R.; Kesel, W.

    1984-01-01

    The main test component of the experimental facility EVA-II/ADAM-II is a helium heated steam reformer bundle with 30 tubes. The tubes are filled with a catalyst of raschig ring type. The main test of the component were related to the power dependence. A series of experiment dealt with the influence of steam/methane ratio on the carbon deposit formation

  19. Alignment of the drift tube detector at the neutrino oscillation experiment OPERA; Alignment des Driftroehrendetektors am Neutrino-Oszillationsexperiment OPERA

    Energy Technology Data Exchange (ETDEWEB)

    Goellnitz, Christoph

    2012-09-15

    The present thesis was composed during the course of the OPERA experiment, which aims to give a direct evidence for neutrino oscillations in the channel {nu}{sub {mu}} {yields} {nu}{sub {tau}}. The OPERA detector is designed to observe the appearance of tau neutrinos in an originally pure muon neutrino beam, the CNGS beam. As important part of the detector the precision tracker (PT), a drift tube detector, consists of 9504 drift tubes in 198 modules. In this thesis, several parts of the slow control of the PT are developed and implemented to ensure operation during data taking over several years. The main part is the geometric calibration, the alignment of the detector. The alignment procedure contains both hardware and software parts, the software methods are developed and applied. Using straight particle tracks, the detector components are geometrically corrected. A special challenge for the alignment for the PT is the fact that at this kind of low-rate experiment only a small number of particle tracks is available. With software-based corrections of the module rotation, a systematic error of 0.2 mrad has been attained, for corrections of translation, a systematic error of 32 {mu}m is reached. For the alignment between two adjacent PT walls, the statistical error is less than 8 {mu}m. All results of the position monitoring system are considered. All developed methods are tested with Monte Carlo simulations. The detector requirements ({Delta}p/p {<=} 0.25 below 25 GeV) are met. The analysis of the momentum measurement for high energies above 25 GeV demonstrates the resulting improvement. The mean momentum is falling significantly using the new alignment values. The significance of the detector alignment becomes most evident in the analysis of cosmic particles. The muon charge ratio R{sub {mu}} is expected not to be angular dependent. The {chi}{sup 2} probability of the measured distribution improves up to 58%. The muon charge ratio was also investigated in

  20. Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube

    International Nuclear Information System (INIS)

    Castanon C, Ma. del P.; Catilla H, P.; Gomez M, J.J.

    1985-01-01

    This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor methods. Various authors for the past 20 years have tried to perform examinations with different radionuclides in order to detect bleeding sites of the lower digestive tract. Our study demonstrates the possibility of detecting this type of pathology by means of studies with colloids and labelled erithrocytes. (author)

  1. Pilot experiments with relativistic uranium projectile and fission fragments thermalized in a cryogenic gas-filled stopping cell

    Energy Technology Data Exchange (ETDEWEB)

    Reiter, Moritz Pascal

    2015-07-01

    High precision experiments and decay spectroscopy of exotic nuclei are of great interest for nuclear structure and nuclear astro-physics. They allow for studies of the nuclear structure far from stability, test of fundamental interactions and symmetries and give important input for the understanding of the nuclear synthesis in the universe. In the context of this work a second generation stopping cell for the low energy branch of the Super-FRS was commissioned at the FRS at GSI and significant improvements were made to the device. The prototype stopping cell is designed as a cryogenic stopping cell (CSC), featuring enhanced cleanliness and high area density. The CSC was brought into full operation and its performance characteristics were investigated including the maximal area density, extraction times, cleanliness and extraction efficiencies. In three commissioning experiments at the current GSI FRS facility in 2011, 2012 and 2014 up to 22 isotopes from 14 elements produced by in-flight projectile fragmentation and fission of {sup 238}U could be thermalized and extracted with high efficiency. For the first time projectile and fission fragmentation produced at 1000 MeV/u could be thermalized in a stopping cell and provided as a low-energy beam of high brilliance for high precision experiments. The technical improvements of the CSC, such as an improved RF carpet, new cryocooler-based cooling system, a monitoring system of the cleanliness and the high density operation, made it possible to thermalize heavy {sup 238}U projectile fragments with total efficiencies of about 20% in the 2014 experiment. In addition the improvements lead to an increase in the stability and reliability of the CSC and the performance of the CSC during online experiments at the FRS Ion Catcher showed that the utilized techniques are ready for the final CSC for the low-energy branch of the Super-FRS at FAIR. The CSC was operated with an area density of up to 6.3 mg/cm{sup 2} helium during

  2. Realization of radiobiological in vitro cell experiments at conventional X-ray tubes and unconventional radiation sources

    International Nuclear Information System (INIS)

    Beyreuther, Elke

    2010-01-01

    More than hundred years after the discovery of X-rays different kinds of ionizing radiation are ubiquitous in medicine, applied to clinical diagnostics and cancer treatment as well. Irrespective of their nature, the widespread application of radiation implies its precise dosimetric characterization and detailed knowledge of the radiobiological effects induced in cancerous and normal tissue. Starting with in vitro cell irradiation experiments, which define basic parameters for the subsequent tissue and animal studies, the whole multi-stage process is completed by clinical trials that translate the results of fundamental research into clinical application. In this context, the present dissertation focuses on the establishment of radiobiological in vitro cell experiments at unconventional, but clinical relevant radiation qualities. In the first part of the present work the energy dependent biological effectiveness of photons was studied examining low-energy X-rays (≤ 50 keV), as used for mammography, and high-energy photons (≥ 20 MeV) as proposed for future radiotherapy. Cell irradiation experiments have been performed at conventional X-ray tubes providing low-energy photons and 200 kV reference radiation as well. In parallel, unconventional quasi-monochromatic channeling X-rays and high-energy bremsstrahlung available at the radiation source ELBE of the Forschungszentrum Dresden-Rossendorf were considered for radiobiological experimentation. For their precise dosimetric characterization dosimeters based on the thermally stimulated emission of exoelectrons and on radiochromic films were evaluated, whereas just the latter was found to be suitable for the determination of absolute doses and spatial dose distributions at cell position. Standard ionization chambers were deployed for the online control of cell irradiation experiments. Radiobiological effects were analyzed in human mammary epithelial cells on different subcellular levels revealing an increasing amount

  3. Realization of radiobiological in vitro cell experiments at conventional X-ray tubes and unconventional radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Beyreuther, Elke

    2010-09-10

    More than hundred years after the discovery of X-rays different kinds of ionizing radiation are ubiquitous in medicine, applied to clinical diagnostics and cancer treatment as well. Irrespective of their nature, the widespread application of radiation implies its precise dosimetric characterization and detailed knowledge of the radiobiological effects induced in cancerous and normal tissue. Starting with in vitro cell irradiation experiments, which define basic parameters for the subsequent tissue and animal studies, the whole multi-stage process is completed by clinical trials that translate the results of fundamental research into clinical application. In this context, the present dissertation focuses on the establishment of radiobiological in vitro cell experiments at unconventional, but clinical relevant radiation qualities. In the first part of the present work the energy dependent biological effectiveness of photons was studied examining low-energy X-rays (≤ 50 keV), as used for mammography, and high-energy photons (≥ 20 MeV) as proposed for future radiotherapy. Cell irradiation experiments have been performed at conventional X-ray tubes providing low-energy photons and 200 kV reference radiation as well. In parallel, unconventional quasi-monochromatic channeling X-rays and high-energy bremsstrahlung available at the radiation source ELBE of the Forschungszentrum Dresden-Rossendorf were considered for radiobiological experimentation. For their precise dosimetric characterization dosimeters based on the thermally stimulated emission of exoelectrons and on radiochromic films were evaluated, whereas just the latter was found to be suitable for the determination of absolute doses and spatial dose distributions at cell position. Standard ionization chambers were deployed for the online control of cell irradiation experiments. Radiobiological effects were analyzed in human mammary epithelial cells on different subcellular levels revealing an increasing amount

  4. Drift tube based pseudorapidity assignment of the level-1 muon trigger for the Compact Muon Solenoid experiment at CERN

    International Nuclear Information System (INIS)

    The Compact Muon Solenoid experiment (CMS) under construction at the CERN Large Hadron Collider (LHC), will explore new physics at high energies. Proton-proton collisions at a centre of mass energy of 14 TeV and heavy-ion collisions will be studied. Muons with large transverse momenta are expected to be among the decay products of many new particles. Their identification and selection is the task of the trigger system. Specifically, the level-1 muon trigger has to search for muon candidates and to determine their parameters at a rate of 40 MHz, corresponding to a beam-crossing interval of 25 ns. The precise knowledge of the spatial parameters of a track enables to make full use of the possibility to select topological trigger conditions already at level-1 in the CMS experiment. Track segments measured in orthogonal layers of drift tube chambers are combined to form a muon candidate. Its transverse momentum is calculated from the track curvature in the r/phi (cursive,open) Greek-projection caused by a magnetic field along the beam direction z. The azimuthal angle phi (cursive,open) Greek in the plane transverse to the beam is also determined. The pseudorapidity η is a function of the track angle θ relative to the beam axis. Using the information from the bending plane projection only enables a coarse assignment of η in the central region of CMS by determining which chambers were crossed by the track. A method to assign η-values of much greater precision is presented. It relies on track finding performed in the non-bending plane r/z and on matching the found tracks with those of the r/phi (cursive,open) Greek-projection. The requirements, the chosen algorithm, its simulated performance and the feasibility for a hardware implementation are described

  5. Nasotracheal tube wire support: a safety device in maxillofacial surgery technical note after five years of experience

    Directory of Open Access Journals (Sweden)

    Fernando Melhem Elias

    2014-03-01

    Full Text Available A well fixed endotracheal tube is essential for safety during general anesthesia. In maxillofacial surgeries, securely fixing a nasotracheal tube in place has always been problematic. The aim of this article is to describe a simple but effective technique to fasten the nasotracheal tube using a wire support that allows a full range of head movement without interference in the surgical field. During the last 5 years, this device was successfully used in almost two hundred patients with very few complications.

  6. Fabrication experience of sodium bonded metallic test fuel with U-6%Zr in T91 clad tube for irradiation in FBTR

    International Nuclear Information System (INIS)

    Muralidaran, P.; Prabhu, T.V.; Manivannan, A.; Vinod, A.V.; Padmanabhan, R.; Ravisankar, G.; Ganesan, V.; Vasudeva Rao, P.R.

    2012-01-01

    Future fast reactors in India will be fuelled by metallic alloys to achieve the enhanced breeding necessary to ensure rapid growth of power generation. Since, experience in fabrication and irradiation of metallic alloy fuel does not exist in the country, it is necessary to generate fabrication and irradiation experience before launching commercial FBRs with metallic alloy fuel. As part of this development, sodium bonded metallic test fuel pin fabrication was taken up at IGCAR. This paper describes the fabrication experience of sodium bonded metallic test fuel pin using Nat. U-6%Zr and T91 clad tube towards test irradiation in FBTR at Chemistry Group

  7. Gastrostomy Tube Weaning and Treatment of Severe Selective Eating in Childhood: Experience in Israel Using an Intensive Three Week Program.

    Science.gov (United States)

    Shalem, Tzippora; Fradkin, Akiva; Dunitz-Scheer, Marguerite; Sadeh-Kon, Tal; Goz-Gulik, Tali; Fishler, Yael; Weiss, Batia

    2016-06-01

    Children dependent on gastrostomy tube feeding and those with extremely selective eating comprise the most challenging groups of early childhood eating disorders. We established, for the first time in Israel, a 3 week intensive weaning and treatment program for these patients based on the "Graz model." To investigate the Graz model for tube weaning and for treating severe selective eating disorders in one center in Israel. Pre-program assessment of patients' suitability to participate was performed 3 months prior to the study, and a treatment goal was set for each patient. The program included a multidisciplinary outpatient or inpatient 3 week treatment course. The major outcome measures were achievement of the target goal of complete or partial tube weaning for those with tube dependency, and expansion of the child's nutritional diversity for those with selective eating. Thirty-four children, 28 with tube dependency and 6 with selective eating, participated in four programs conducted over 24 months. Their mean age was 4.3 ± 0.37 years. Of all patients, 29 (85%) achieved the target goal (24 who were tube-dependent and 5 selective eaters). One patient was excluded due to aspiration pneumonia. After 6 months follow-up, 24 of 26 available patients (92%) maintained their target or improved. This intensive 3 week program was highly effective in weaning children with gastrostomy tube dependency and ameliorating severe selective eating. Preliminary evaluation of the family is necessary for completion of the program and achieving the child's personal goal, as are an experienced multidisciplinary team and the appropriate hospital setup, i.e., inpatient or outpatient.

  8. An original approach to fill the gap in the earthquake disaster experience - a proposal for 'the archive of the quake experience' -

    Science.gov (United States)

    Tanaka, Y.; Hirayama, Y.; Kuroda, S.; Yoshida, M.

    2015-12-01

    People without severe disaster experience infallibly forget even the extraordinary one like 3.11 as time advances. Therefore, to improve the resilient society, an ingenious attempt to keep people's memory of disaster not to fade away is necessary. Since 2011, we have been caring out earthquake disaster drills for residents of high-rise apartments, for schoolchildren, for citizens of the coastal area, etc. Using a portable earthquake simulator (1), the drill consists of three parts, the first: a short lecture explaining characteristic quakes expected for Japanese people to have in the future, the second: reliving experience of major earthquakes hit Japan since 1995, and the third: a short lecture for preparation that can be done at home and/or in an office. For the quake experience, although it is two dimensional movement, the real earthquake observation record is used to control the simulator to provide people to relive an experience of different kinds of earthquake including the long period motion of skyscrapers. Feedback of the drill is always positive because participants understand that the reliving the quake experience with proper lectures is one of the best method to communicate the past disasters to their family and to inherit them to the next generation. There are several kinds of archive for disaster as inheritance such as pictures, movies, documents, interviews, and so on. In addition to them, here we propose to construct 'the archive of the quake experience' which compiles observed data ready to relive with the simulator. We would like to show some movies of our quake drill in the presentation. Reference: (1) Kuroda, S. et al. (2012), "Development of portable earthquake simulator for enlightenment of disaster preparedness", 15th World Conference on Earthquake Engineering 2012, Vol. 12, 9412-9420.

  9. About Dental Amalgam Fillings

    Science.gov (United States)

    ... Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More sharing ... I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material used ...

  10. Droplet Measurement below Single-Layer Grid Fill

    Directory of Open Access Journals (Sweden)

    Vitkovic Pavol

    2016-01-01

    Full Text Available The main part of the heat transfer in a cooling tower is in a fill zone. This one is consist of a cooling fill. For the cooling tower is used a film fill or grid fill or splash fill in the generally. The grid fill has lower heat transfer performance like film fill usually. But their advantage is high resistance to blockage of the fill. The grid fill is consisted with independent layers made from plastic usually. The layers consist of several bars connected to the different shapes. For experiment was used the rhombus shape. The drops diameter was measured above and below the Grid fill.

  11. Expansion tube test time predictions

    Science.gov (United States)

    Gourlay, Christopher M.

    1988-01-01

    The interaction of an interface between two gases and strong expansion is investigated and the effect on flow in an expansion tube is examined. Two mechanisms for the unsteady Pitot-pressure fluctuations found in the test section of an expansion tube are proposed. The first mechanism depends on the Rayleigh-Taylor instability of the driver-test gas interface in the presence of a strong expansion. The second mechanism depends on the reflection of the strong expansion from the interface. Predictions compare favorably with experimental results. The theory is expected to be independent of the absolute values of the initial expansion tube filling pressures.

  12. Experience in ultrasonic gap measurement between calandria tubes and liquid injection shutdown systems nozzles in Bruce Nuclear Generating Station

    International Nuclear Information System (INIS)

    Abucay, R.C.; Mahil, K.S.; Goszczynski, J.J.

    1995-01-01

    The gaps between calandria tubes (CT) and Liquid Injection Shutdown System (LISS) nozzles at the Bruce Nuclear Generating Station ''A'' (Bruce A) are known to decrease with time due to radiation induced creep/sag of the calandria tubes. If this gap decreases to a point where the calandria tubes come into contact with the LISS nozzle, the calandria tubes could fail as a result of fretting damage. Proximity measurements were needed to verify the analytical models and ensure that CT/LISS nozzle contact does not occur earlier than predicted. The technique used was originally developed at Ontario Hydro Technologies (formerly Ontario Hydro Research Division) in the late seventies and put into practical use by Research and Productivity Council (RPC) of New Brunswick, who carried out similar measurements at Point Lepreau NGS in 1989 and 1991. The gap measurement was accomplished y inserting an inspection probe, containing four ultrasonic transducers (2 to measure gaps and 2 to check for probe tilt) and a Fredericks electrolytic potentiometer as a probe rotational sensor, inside LISS Nozzle number-sign 7. The ultrasonic measurements were fed to a system computer that was programmed to convert the readings into fully compensated gaps, taking into account moderator heavy water temperature and probe tilt. Since the measured gaps were found to be generally larger than predicted, the time to CT/LISS nozzle contact is now being re-evaluated and the planned LISS nozzle replacement will likely be deferred, resulting in considerable savings

  13. British Industries Collaborative Exponential Programme. Vol. I. Introduction: Exponential experiments on rods and tubes of natural uranium metal

    International Nuclear Information System (INIS)

    1963-03-01

    The experimental techniques used in the performance of exponential buckling measurements are described. The results are given of buckling measurements on a wide range of graphite lattices in which the fuel elements consisted of rods or tubes of natural uranium metal. The observed buckling values are correlated with theory. (author)

  14. Geotextile Tube Structures Guidelines for Contract Specifications

    Science.gov (United States)

    2006-09-01

    Nonwoven fabrics: Diaphragm Bursting Strength Tester Method ASTM D 3884 (1992) Abrasion Resistance of Textile Fabrics (Rotary Platform, Double-Head... filter cloth, excavation of borrow material, transportation of borrow material, filling of the tubes, coating of the completed tubes, disposal of waste

  15. Prestaciones del Detector Central de Muones del Experimento CMS: las Camaras de Deriva y su Sistema de Trigger (Performance of the Central Muon Detector of the Experiment CMS: the Drift Tube Chambers and its Trigger System)

    CERN Document Server

    Muñoz, Carlos Villanueva

    2007-01-01

    Prestaciones del Detector Central de Muones del Experimento CMS: las Camaras de Deriva y su Sistema de Trigger (Performance of the Central Muon Detector of the Experiment CMS: the Drift Tube Chambers and its Trigger System)

  16. Control rod guide tube wear in operating reactors; operating experience report. Technical report December 1977-December 1979

    International Nuclear Information System (INIS)

    Riggs, R.

    1980-04-01

    Evidence of control rod guide tube wear has been observed in operating pressurized water reactors. The cause of this wear is identified as flow-induced vibration of the control rods. This report describes the measures being taken by both the industry and the NRC to deal with this matter. The staff also presents its technical positions and requirements to support continued operation of the plants as of December 1979 pending completion of this generic effort

  17. Use of Gore-Tex tubing as a conduit for inferior alveolar and lingual nerve repair: experience with 6 cases.

    Science.gov (United States)

    Pitta, M C; Wolford, L M; Mehra, P; Hopkin, J

    2001-05-01

    This report evaluates treatment outcomes associated with the use of Gore-Tex (GT; W.L. Gore & Associates, Flagstaff, AZ) vein graft tubing as a conduit for repair of inferior alveolar nerve (IAN) and lingual nerve (LN) continuity defects. Six patients (5 female and 1 male) with painful dysesthesia secondary to injuries of the IAN (n = 3) or LN (n = 3) underwent surgical exploration and resection of pathologic tissue. Reconstruction of the resultant continuity defects was performed using 3-mm diameter GT tubing sutured to the epineurium of the proximal and distal nerve trunks. Nerve reconstruction was performed an average of 20 months after injury (range, 4 to 48 months). Patients were tested before and after surgery with the following tests: subjective pain level using an analogue scale, sharp stimulus, touch, cold sensation, directional sense, and 2-point discrimination. Four patients reported no change in subjective pain level, and 2 patients had minimal decrease in pain. Two patients reported some sensation to sharp stimulus, and 1 patient was hypersensitive. Three patients responded to touch, and 3 had no response. Four patients had no response to cold sensation, and 2 had a delayed response. Only 1 patient could detect brushstroke direction. Three patients had no response to 2-point discrimination, and 3 responded at greater than 20 mm. Use of GT tubing in this group of patients produced poor clinical outcomes and is not recommended for nerve reconstruction of IAN and LN continuity defects. Copyright 2001 American Association of Oral and Maxillofacial Surgeons

  18. The YouTube Makeup Class

    Science.gov (United States)

    Haase, David G.

    2009-05-01

    When a college instructor goes out of town and must miss a lecture, the standard options are to cancel the class meeting or to enlist a colleague to fill in. In the former case a teaching opportunity is lost; in the latter the substitute may not lead the class in the same way as the instructor. Some students routinely skip lectures by a guest instructor, in the belief that the material in the substitute lecture will not be covered on the exam. There are other makeup options such as a directed study assignment. For instance, a missed class is sometimes a good opportunity to require students to investigate web-based simulations such as Physlets® that illustrate the class topics. These are most effective if the students are given a clear structure and if there are questions that the students must answer from their investigations with the Physlets. But many students are more comfortable with the audio and visual communication that occurs in the classroom. Web 2.0 technology, e.g., YouTube (http://www.youtube.com), makes it convenient for faculty to upload videos of lectures and demonstrations that can be used for makeup classes. College students already use YouTube for entertainment, and the YouTube format is simple to view on any web-connected computer. Although some universities have highly developed media delivery systems, YouTube is extremely convenient and accessible by anyone. This paper discusses how a YouTube makeup class can be efficiently produced and structured to be an effective learning experience.

  19. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for

  20. Gas-Filled Capillary Model

    International Nuclear Information System (INIS)

    Steinhauer, L. C.; Kimura, W. D.

    2006-01-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment

  1. A Proposal for the Upgrade of the Muon Drift Tubes Trigger for the CMS Experiment at the HL-LHC

    Science.gov (United States)

    Pozzobon, Nicola; Zotto, Pierluigi; Montecassiano, Fabio

    2016-11-01

    A major upgrade of the readout and trigger electronics of the CMS Drift Tubes muon detector is foreseen in order to allow its efficient operation at the High Luminosity LHC. A proposal for a new L1 Trigger Primitives Generator for this detector is presented, featuring an algorithm operating on the time of charge collection measurements provided by the asynchronous readout of the new TDC system being developed. The algorithm is being designed around the implementation in state-of-the-art FPGA devices of the original development of a Compact Hough Transform (CHT) algorithm combined with a Majority Mean-Timer, to identify both the parent bunch crossing and the muon track parameters. The current state of the design is presented along with the performance requirements, focusing on the future developments.

  2. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-01-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at…

  3. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  4. New Bayesian inference method using two steps of Markov chain Monte Carlo and its application to shock tube experiment data of Furan oxidation

    KAUST Repository

    Kim, Daesang

    2016-01-06

    A new Bayesian inference method has been developed and applied to Furan shock tube experimental data for efficient statistical inferences of the Arrhenius parameters of two OH radical consumption reactions. The collected experimental data, which consist of time series signals of OH radical concentrations of 14 shock tube experiments, may require several days for MCMC computations even with the support of a fast surrogate of the combustion simulation model, while the new method reduces it to several hours by splitting the process into two steps of MCMC: the first inference of rate constants and the second inference of the Arrhenius parameters. Each step has low dimensional parameter spaces and the second step does not need the executions of the combustion simulation. Furthermore, the new approach has more flexibility in choosing the ranges of the inference parameters, and the higher speed and flexibility enable the more accurate inferences and the analyses of the propagation of errors in the measured temperatures and the alignment of the experimental time to the inference results.

  5. Buckling of thin walled composite cylindrical shell filled with solid propellant

    Science.gov (United States)

    Dash, A. P.; Velmurugan, R.; Prasad, M. S. R.

    2017-12-01

    This paper investigates the buckling of thin walled composite cylindrical tubes that are partially filled with solid propellant equivalent elastic filler. Experimental investigation is conducted on thin composite tubes made out of S2-glass epoxy, which is made by using filament winding technique. The composite tubes are filled with elastic filler having similar mechanical properties as that of a typical solid propellant used in rocket motors. The tubes are tested for their buckling strength against the external pressure in the presence of the filler. Experimental data confirms the enhancement of external pressure carrying capacity of the composite tubes by up to three times as that of empty tubes for a volumetric loading fraction (VLF) of 0.9. Furthermore, the finite element based geometric nonlinearity analysis predicts the buckling behaviour of the partially filled composite tubes close to the experimental results.

  6. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  7. Innovative energy absorbing devices based on composite tubes

    Science.gov (United States)

    Tiwari, Chandrashekhar

    Analytical and experimental study of innovative load limiting and energy absorbing devices are presented here. The devices are based on composite tubes and can be categorized in to two groups based upon the energy absorbing mechanisms exhibited by them, namely: foam crushing and foam fracturing. The device based on foam crushing as the energy absorbing mechanism is composed of light weight elastic-plastic foam filling inside an angle ply composite tube. The tube is tailored to have a high Poisson’s ratio (>20). Upon being loaded the device experiences large transverse contraction resulting in rapid decrease in diameter. At a certain axial load the foam core begins to crush and energy is dissipated. This device is termed as crush tube device. The device based upon foam shear fracture as the energy absorbing mechanism involves an elastic-plastic core foam in annulus of two concentric extension-twist coupled composite tubes with opposite angles of fibers. The core foam is bonded to the inner and outer tube walls. Upon being loaded axially, the tubes twist in opposite directions and fracture the core foam in out of plane shear and thus dissipate the energy stored. The device is termed as sandwich core device (SCD). The devices exhibit variations in force-displacement characteristics with changes in design and material parameters, resulting in wide range of energy absorption capabilities. A flexible matrix composite system was selected, which was composed of high stiffness carbon fibers as reinforcements in relatively low stiffness polyurethane matrix, based upon large strain to failure capabilities and large beneficial elastic couplings. Linear and non-linear analytical models were developed encapsulating large deformation theory of the laminated composite shells (using non-linear strain energy formulation) to the fracture mechanics of core foam and elastic-plastic deformation theory of the foam filling. The non-linear model is capable of including material and

  8. YouTube Videos to Create a "Virtual Hospital Experience" for Hip and Knee Replacement Patients to Decrease Preoperative Anxiety: A Randomized Trial.

    Science.gov (United States)

    O'Connor, Mary I; Brennan, Katharyn; Kazmerchak, Shari; Pratt, Jason

    2016-04-18

    With declining reimbursement to health care systems, face-to-face time between patients and providers to optimize preoperative education and counseling may be challenging. Because high patient anxiety prior to surgery has been linked to more severe and persistent pain after joint replacement surgery, the Orthopedic Surgery Department at Mayo Clinic in Florida created a playlist of 16 YouTube videos aimed at creating a virtual hospital experience for primary total hip and knee joint replacement patients. A randomized trial was then performed to evaluate the potential impact of viewing this playlist on preoperative anxiety. Each patient completed a Generalized Anxiety Disorder (GAD) score assessment at the time of the routine preoperative clinic visit and then randomized based on his/her gender, type of surgery, and initial GAD score to either the control group of standard education (education at face-to-face clinical visits as well as printed educational materials) or the treatment group (standard education plus access to the YouTube playlist). On the morning of the patient's surgery, the same survey was repeated. Of the 65 patients who consented to participate in the study, 53 completed the study (82%) with 28 of 29 (97% completed) in the control group and 25 of 36 (69% completed) in the treatment group. Overall, the results showed a trend toward less anxiety in patients who viewed the YouTube videos; this was exhibited by a reduction in the median GAD score by 1 point. This trend is more clearly present in patients with high preoperative anxiety (predominantly women), as seen in the reduction of the median GAD score by 6 points in the treatment group. Although our experience is limited, our results indicate that a series of tailored videos may decrease patient anxiety preoperatively. We recommend further exploration of both this concept and the use of social media tools in preoperative patient education. Clinicaltrials.gov NCT02546180; http

  9. Neutron tubes

    Science.gov (United States)

    Leung, Ka-Ngo [Hercules, CA; Lou, Tak Pui [Berkeley, CA; Reijonen, Jani [Oakland, CA

    2008-03-11

    A neutron tube or generator is based on a RF driven plasma ion source having a quartz or other chamber surrounded by an external RF antenna. A deuterium or mixed deuterium/tritium (or even just a tritium) plasma is generated in the chamber and D or D/T (or T) ions are extracted from the plasma. A neutron generating target is positioned so that the ion beam is incident thereon and loads the target. Incident ions cause D-D or D-T (or T-T) reactions which generate neutrons. Various embodiments differ primarily in size of the chamber and position and shape of the neutron generating target. Some neutron generators are small enough for implantation in the body. The target may be at the end of a catheter-like drift tube. The target may have a tapered or conical surface to increase target surface area.

  10. On the propagation mechanism of a detonation wave in a round tube with orifice plates

    Science.gov (United States)

    Ciccarelli, G.; Cross, M.

    2016-09-01

    This study deals with the investigation of the detonation propagation mechanism in a circular tube with orifice plates. Experiments were performed with hydrogen air in a 10-cm-inner-diameter tube with the second half of the tube filled with equally spaced orifice plates. A self-sustained Chapman-Jouguet (CJ) detonation wave was initiated in the smooth first half of the tube and transmitted into the orifice-plate-laden second half of the tube. The details of the propagation were obtained using the soot-foil technique. Two types of foils were used between obstacles, a wall-foil placed on the tube wall, and a flat-foil (sooted on both sides) placed horizontally across the diameter of the tube. When placed after the first orifice plate, the flat foil shows symmetric detonation wave diffraction and failure, while the wall foil shows re-initiation via multiple local hot spots created when the decoupled shock wave interacts with the tube wall. At the end of the tube, where the detonation propagated at an average velocity much lower than the theoretical CJ value, the detonation propagation is much more asymmetric with only a few hot spots on the tube wall leading to local detonation initiation. Consecutive foils also show that the detonation structure changes after each obstacle interaction. For a mixture near the detonation propagation limit, detonation re-initiation occurs at a single wall hot spot producing a patch of small detonation cells. The local overdriven detonation wave is short lived, but is sufficient to keep the global explosion front propagating. Results associated with the effect of orifice plate blockage and spacing on the detonation propagation mechanism are also presented.

  11. Sealing And Filling Cracks In Asphalt Pavements

    Science.gov (United States)

    1999-11-01

    The primary objective of the crack treatment experiment was to determine the most effective and economical materials and methods for conducting crack-sealing and crack-filling operations. Secondary objectives included the identification of performanc...

  12. Naturally Occurring Peer Support through Social Media: The Experiences of Individuals with Severe Mental Illness Using YouTube

    NARCIS (Netherlands)

    Naslund, J.A.; Grande, S.W.; Aschbrenner, K.A.; Elwyn, G.

    2014-01-01

    Increasingly, people with diverse health conditions turn to social media to share their illness experiences or seek advice from others with similar health concerns. This unstructured medium may represent a platform on which individuals with severe mental illness naturally provide and receive peer

  13. Iron-Oxide-Filled Carbon Nanotubes

    Science.gov (United States)

    Cava, Carlos Eduardo

    Carbon nanotubes (CNT) are recognized as one of the most important materials in the recent history of nanotechnology. In the last 25 years, intensive studies about this material have led to new ideas for the use of nanomaterials in many technological products. The unique properties presented by this material allow its use in a wide range of applications. Known as a crystalline material, CNTs can, however, interact with many materials in different manners, making it easy to use as a composite. One interesting aspect is the possibility of filling the CNT hollow core with a foreign material, forming a filled CNT. This composite can be achieved in situ using chemical vapor deposition and arc-discharge or after the synthesis, by chemical methods. The technique choice to achieve the filled CNT depends on the material inside the CNT. The resulting material can provide new electrical, optical, and mechanical features due to the synergistic effect between the CNTs themselves and the filling, which can originate new multifunctional materials. Concerning the electrical conductivity and the gas sensing, the possible interaction between the CNT and the filling can modify the electronic structure of the material and, consequently, affect the kind of interaction between the CNT and different gases. Commonly, the filled CNTs are obtained with magnetic materials inside the tube, which are also precursors in their syntheses; this feature brings new possibilities to magnetic devices, such as memories. Among them, iron-oxide-filled carbon nanotubes have been suggested as a technological material for use in magnetic, electrical, and medical applications. Therefore, this kind of nanocomposite material can be useful in the preparation of versatile and durable solid-state sensors, memory devices, with simple manufacturing and in a proper size. In this chapter, an introduction about the production and application of iron-oxide-filled CNTs in its many different forms will be presented.

  14. Seismic behavior of conxl connections in concrete filled steel Tube ...

    African Journals Online (AJOL)

    For this purpose, three samples of ConXL connections without concrete filler, with concrete filler and with concrete filler and stiffener plates inside the column were studied using Abaqus software. The results demonstrated that the ductility of the ConXL connection without concrete filler is more than the two other samples, ...

  15. Performance Study of Concrete-Filled Steel Tubes

    Directory of Open Access Journals (Sweden)

    Chair A.

    2014-04-01

    This type of structure can be used in Algeria for rehabilitating old buildings, or strengthening reinforced concretecolumns to improve their structural performance. However, new regulatory measures should be considered in order tointroduce this compound element in the construction.

  16. Gas-filled detectors

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter deals with the nature of the interaction of radiation with gas-filled radiation detectors. A description of the theory of operation of the ionization chamber and Geiger-Mueller counter is included

  17. Treatment of middle ear ventilation disorders: sheep as animal model for stenting the human Eustachian tube--a cadaver study.

    Directory of Open Access Journals (Sweden)

    Felicitas Miller

    Full Text Available Eustachian tube disorders can lead to chronic otitis media with consecutive conductive hearing loss. To improve treatment and to develop new types of implants such as stents, an adequate experimental animal model is required. As the middle ear of sheep is known to be comparable to the human middle ear, the dimensions of the Eustachian tube in two strains of sheep were investigated. The Eustachian tube and middle ear of half heads of heathland and blackface sheep were filled with silicone rubber, blended with barium sulfate to induce X-ray visibility. Images were taken by digital volume tomography. The tubes were segmented, and a three-dimensional model of every Eustachian tube was generated. The lengths, diameters and shapes were determined. Additionally, the feasibility of endoscopic stent implantation and fixation was tested in cadaver experiments. The length of the tube between ostium pharyngeum and the isthmus and the diameters were comparable to published values for the human tube. The tube was easily accessible through the nose, and then stents could be implanted and fixed at the isthmus. The sheep appears to be a promising model for testing new stent treatments for middle ear ventilation disorders.

  18. Determinação de volumes e pressões de balonetes de tubos traqueais insuflados com ar ambiente ou óxido nitroso Determinación de volúmenes y presiones de balones de tubos traqueales insuflados con aire ambiente u óxido nitroso Volume and pressure of tracheal tube cuffs filled with air or nitrous oxide

    Directory of Open Access Journals (Sweden)

    Ernesto Leonardo Cárpio Peña

    2004-06-01

    balanceada con entubación orotraqueal. El balón fue insuflado conforme criterios clínicos. Las medidas de base fueron realizadas después de 15 minutos del inicio de la anestesia con un manómetro aneróide calibrado en cm de H2O y dieron los valores iniciales de presión y volumen. Los pacientes fueron divididos en dos grupos: balón reinsuflado con aire ambiente, grupo A, o con óxido nitroso, grupo B. Las medidas de presión fueron obtenidas en intervalos hasta la primera hora y los resultados comparados. RESULTADOS: Los grupos se mostraron comparables para edad y sexo. En ambos grupos los valores basales medios para presión fueron próximos de 40 cmH2O con 8 ml de volumen. En el grupo con aire ambiente, las presiones aumentaron hasta 36 cmH2O en una hora. En el grupo de balón insuflado con N2O, las presiones cayeron abajo de 20 cmH2O entre 20 y 30 minutos de anestesia. CONCLUSIONES: El uso de N2O a 100% para insuflación del balón de sonda traqueal no constituye método seguro, acarreando progresiva pérdida de la capacidad de vedación. El uso de aire ambiente promueve aumento de volumen y de presión en el balón, aumentando la posibilidad de lesión de la mucosa traqueal.BACKGROUND AND OBJECTIVES: Tracheal tube cuff pressure against tracheal wall should to prevent air leaked or pulmonary aspiration, allowing adequate capillary blood flow. This study aimed at determining pressure variations of tracheal tube cuffs filled with air or 100% nitrous oxide. METHODS: Participated in this study 30 patients submitted to balanced general anesthesia with tracheal intubation. Cuff was inflated according to clinical criteria. The intracuff pressure measurements were undertaken after 15 minutes of anesthesia by means of an aneroid manometer gaged in cm of H2O and have provided initial pressure and volume values. The patients was allocated in two groups: cuff inflated with air, group A, and with nitrous oxide, group B. Measurements were recorded during one hour and results were

  19. Filling a Conical Cavity

    Science.gov (United States)

    Nye, Kyle; Eslam-Panah, Azar

    2016-11-01

    Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.

  20. Disinfection of Biofilms in Tubes with Ultraviolet Light

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2009-01-01

    Bacterial biofilms on long-term catheters are a major source of infection. We demonstrate here the potential of UVC light emitting diodes (LED) for disinfection purposes in catheter like tubes contaminated with biofilm. We show that UVC Light propagation is possible through teflon tubes using...... that the UVC light attenuation inside the tube can be described by an exponential function depending of tube length and various loss mechanisms. The disinfection efficiency of the UVC diodes is demonstrated on tubes contaminated artificially with a Pseudomonas aeruginosa biofilm. The tubes were connected...... to a flow system and biofilms were produced during a three day period. Tubes in lengths of 10 cm (FEP teflon) were contaminated. Tubes for control and for UVC treatment were contaminated in parallel. The control and UVC treated tubes were both filled with a 20 % NaCl solution during the UVC treatment time...

  1. Evaluation of Surface and Transport Limitations to the Rate of Calcite Dissolution Using Pore Scale Modeling of a Capillary Tube Experiment at pCO2 4 bar

    Science.gov (United States)

    Molins, S.; Trebotich, D.; Yang, L.; Ajo Franklin, J. B.; Ligocki, T.; Shen, C.; Steefel, C. I.

    2013-12-01

    Mineral trapping is generally considered to account for most of the long-term trapping of CO2 in the subsurface. Prediction of mineral trapping at the reservoir scale requires knowledge of continuum-scale mineral dissolution and precipitation rates. However, processes that take place at the pore scale (e.g., transport limitation to reactive surfaces) affect rates applicable at the continuum scale. To explore the pore scale processes that result in the discrepancy between rates measured in laboratory experiments and those calibrated from continuum-scale models, we have developed a high-resolution pore scale model of a capillary tube experiment. The capillary tube (L=0.7-cm, D=500-μm) is packed with crushed calcite (Iceland spar) and the resulting 3D pore structure is imaged by X-ray computed microtomography (XCMT) at Berkeley Lab's Advanced Light Source at a 0.899-μm resolution. A solution in equilibrium with a partial pressure of CO2 of 4 bars is injected at a rate of 5 microliter/min and the effluent concentrations of calcium are measured to ensure steady state conditions are achieved. A simulation domain is constructed from the XCMT image using implicit functions to represent the mineral surface locally on a grid. The pore-scale reactive transport model is comprised of high performance simulation tools and algorithms for incompressible Navier-Stokes flow, advective-diffusive transport and multicomponent geochemical reactions. Simulations are performed using 6,144 processors on NERSC's Cray XE6 Hopper to achieve a grid resolution of 2.32 μm. Equivalent continuum scale simulations are also performed to evaluate the effect of pore scale processes. Comparison of results is performed based on flux-averaged effluent calcium concentrations, which are used as indicator of effective rates in the capillary tube. Results from both pore- and continuum-scale simulations overestimate the calcium effluent concentrations, suggesting that the TST rate expression parameters

  2. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  3. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  4. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  5. A proposed Drift Tubes-seeded muon track trigger for the CMS experiment at the High Luminosity-LHC

    CERN Document Server

    AUTHOR|(CDS)2070813; Lazzizzera, Ignazio; Vanini, Sara; Zotto, Pierluigi

    2016-01-01

    The LHC program at 13 and 14 TeV, after the observation of the candidate SM Higgs boson, will help clarify future subjects of study and shape the needed tools. Any upgrade of the LHC experiments for unprecedented luminosities, such as the High Luminosity-LHC ones, must then maintain the acceptance on electroweak processes that can lead to a detailed study of the properties of the candidate Higgs boson. The acceptance of the key lepton, photon and hadron triggers should be kept such that the overall physics acceptance, in particular for low-mass scale processes, can be the same as the one the experiments featured in 2012.In such a scenario, a new approach to early trigger implementation is needed. One of the major steps will be the inclusion of high-granularity tracking sub-detectors, such as the CMS Silicon Tracker, in taking the early trigger decision. This contribution can be crucial in several tasks, including the confirmation of triggers in other subsystems, and the improvement of the on-line momentum mea...

  6. DEVELOPMENT OF AN ANALYTICAL METHOD TO EVALUATE THE INTEGRITY OF A CALANDRIA TUBE IN THE CASE OF PRESSURE TUBE RUPTURE

    OpenAIRE

    森下 善嗣

    1990-01-01

    An analytical method which consists of two‐dimensional thermal‐hydraulic analysis and three‐dimensional structural analysis has been proposed to evaluate the integrity of a calandria tube in the case of pressure tube rupture in a pressure tube type reactor.In order to validate the method,experiments were carried out with coaxially arranged double tubes simulating a pressure tube and a calandria tube.Experimental data were also comparedwith analytical results with the proposed method.

  7. Experimental study of single taylor bubbles rising in stagnant liquid mixtures inside of vertical tubes

    International Nuclear Information System (INIS)

    Azevedo, Marcos B. de; Faccini, Jose L.H.; Su, Jian

    2015-01-01

    The present work reports an experimental study of single Taylor bubbles rising in vertical tubes filled with water-glycerin mixtures by using the pulse-echo ultrasonic technique. A 2m long acrylic tube with inner diameter of 24 mm was used in the experiments. Initially, the tube was sealed at the ends and filled partially with the liquid mixtures to leave an air pocket of length L 0 at the top end. A Taylor bubble was formed by the inversion of the tube. The rising bubbles were detected by ultrasonic transducers located at the upper part of the tube. The velocity, the length and the pro le of the bubbles and the thickness of the liquid lm around them were obtained from the ultrasonic signals processing. The liquid lm thickness in the vertical tube was also determined by a graphic method that relates the bubble length L b with the initial length of the air pocket L 0 . It was observed that the bubble velocity decreased with increasing viscosity, while the lm thickness increased. It was shown that the liquid lm thickness determined by the graphic method fitted well the higher viscosities data, but overestimated the lower viscosities data. Additionally, the results indicated that some correlations developed to estimate the thickness of liquid films falling down inside/outside of tubes and down a plane surface could be applied to estimate the thickness of liquid films falling around Taylor bubbles in an Inverse Viscosity Number (N f ) range different to those considered in the literature. (author)

  8. Recent ACE 4 Z-pinch experiments: Long implosion time argon loads, uniform fill versus annular shell distributions and the Rayleigh-Taylor instability problem

    International Nuclear Information System (INIS)

    Coleman, P.; Rauch, J.; Rix, W.; Thompson, J.; Wilson, R.

    1997-01-01

    Hammer (1996) and Velikovich (1996) have discussed ways to mitigate the growth of the magneto-Rayleigh-Taylor (MRT) instability in z-pinch (PRS) implosions. They predict that initial mass distributions more complex than a simple annular shell will reduce instability development. Sanford (1996) reported experimental data showing a benefit for a uniform mass distribution compared to a shell; those tests used ''conventional'' load radii of 2.25 and 1.25 cm respectively, and implosion times under 100 ns. However, the instability problem is expected to grow exponentially as the implosion time, or alternatively the initial radius, increases. Thus we made a comparison of a uniform fill load with a shell but at larger radii, 3.6 and 2.5 cm respectively, and at implosion times well above 100 ns. We see nearly a factor of 10X improvement in peak K-shell power and 2X increase in K-shell yield for the uniform mass load. Hence it appears that suitable tailoring of the imploding mass distribution can significantly limit the instability growth

  9. The structure of filled skutterudites and the local vibration behavior of the filling atom

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiaojuan [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zong, Peng-an [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Chen, Xihong [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Tao, Juzhou, E-mail: taoj@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); Lin, He, E-mail: linhe@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201204 (China)

    2017-02-15

    Both of atomic pair distribution function (PDF) and extended x-ray absorption fine structure (EXAFS) experiments have been carried out on unfilled and Yb-filled skutterudites Yb{sub x}Co{sub 4}Sb{sub 12} (x=0, 0.15, 0.2 and 0.25) samples. The structure refinements on PDF data confirm the large amplitude vibration of Yb atom and the dependence of Yb vibration amplitude on the filling content. Temperature dependent EXAFS experiment on filled skutterudites have been carried out at Yb L{sub Ⅲ}-edge in order to explore the local vibration behavior of filled atom. EXAFS experiments show that the Einstein temperature of the filled atom is very low (70.9 K) which agrees with the rattling behavior.

  10. Development of puncture resistance tire tube; Nirinsha no taipankusei kojo cube no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yamagiwa, T.; Nakayama, K.; Kiyota, S.; Tanaka, A. [Honda R and D Co. Ltd., Tokyo (Japan); Makisaka, N.

    1997-10-01

    A new tire tube with a puncture resistance function was developed. The tube is a two-chamber structure having an air chamber and a liquid chamber, and the liquid chamber at the crown-side half of the tube is filled with an anti-puncture sealant during a manufacturing process. In a market test, it was confirmed that the number of puncture cases were reduced by 90 % in comparison with conventional tire tubes by using the newly developed tube. This paper describes the structure of the tube and the characteristics of the tube rubber, and the manufacturing process and durability of the tube. 3 refs., 17 figs.

  11. Use of mobile learning module improves skills in chest tube insertion.

    Science.gov (United States)

    Davis, James S; Garcia, George D; Wyckoff, Mary M; Alsafran, Salman; Graygo, Jill M; Withum, Kelly F; Schulman, Carl I

    2012-09-01

    Just-In-Time Learning is a concept increasingly applied to medical education, and its efficacy must be evaluated. A 3-minute video on chest tube insertion was produced. Consenting participants were assigned to either the video group, which viewed the video on an Apple® iPod Touch immediately before chest tube insertion, or the control group, which received no instruction. Every participant filled out a questionnaire regarding prior chest tube experience. A trained clinician observed participants insert a chest tube on the TraumaMan® task simulator, and assessed performance using a 14-item skills checklist. Overall, 128 healthcare trainees participated, with 50% in the video group. Participants included residents (34.4%, n = 44), medical students (32.8%, n = 42), and U.S. Army Forward Surgical Team members (32.8%, n = 42). Sixty-nine percent of all participants responded that they had never placed a chest tube, but 7% had placed more than 20. Only 25% of the participants had previously used TraumaMan®. Subjects who viewed the video scored better on the skills checklist than the control group (11.09 ± 3.09 versus 7.17 ± 3.56, P animation video is an effective medium for teaching procedural skills. Embedding the video on a mobile device, and allowing trainees to access it immediately before chest tube insertion, may enhance and standardize surgical education for civilians and military personnel. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Leak before break detection-annulus gas monitoring system evolution and operating experience at KGS

    International Nuclear Information System (INIS)

    Jain, D.D.; Sanathkumar, V.V.; Ramamurthy, K.; Nageswara Rao, G.

    2002-01-01

    Full text: Pressurised heavy water reactors (PHWR) at RAPS 1 and 2 and MAPS have provision for detection of pressure tube leak by indirect method. The reactor vessel (calandria) is housed in calandria vault (C/V) filled with air and C/V moisture element indicates the water leak from calandria tube or pressure tube. Further, detection of leak is a cumbersome process. From NAPS onwards, calandria is housed in C/V filled with water, annulus between calandria tube and pressure tube is filled with CO 2 and annulus gas monitoring system (AGMS) is provided by design for detection of any pressure tube leak. The design was improved and AGMS for Kaiga 1 and 2 and RAPS 3 and 4 is having re-circulation mode of operation. The design provides for monitoring dew point of annulus gas (CO 2 ) for indicating the leak and later to identify the pressure tube/calandria tube having leak. The paper deals with operating experience of AGMS at Kaiga generating station (KGS). During the commissioning and initial power operation at KGS, problems were encountered in re-circulation mode. These problems were high radiation field near AGMS piping, high temperature on blower body, blower bearing failure and system leaks. Design modifications were carried out for effective performance of the system for detecting leak before break

  13. Damage evolution in a filled epoxy resin

    International Nuclear Information System (INIS)

    Depoorter, Nicolas; Coutellier, Daniel; Muzic, Markus; Berg-Pollack, Antje; Cai Ye; Zimmermann, Andre

    2006-01-01

    A method is proposed for studying damage evolution in a filled epoxy resin submitted to low-cycle fatigue loading. Transmission electron microscopy analysis was performed, which indicates a damage mechanism that corresponds well to the decreasing slope of the stress-strain hysteresis observed in strain-controlled fatigue experiments. Also, the suggested damage model appears to be suitable for the simulation of strain-controlled cyclic tests and fits the damage evolution of the filled epoxy resin fairly well [de

  14. Space-filling Curves

    Indian Academy of Sciences (India)

    mathematics and computer applications for the last 20 years. He has been a National Science. Talent awardee of. NCERT in mathematics. GENERAL I ARTICLE. Space-filling Curves. ReMittal. In this article some Peano curves are exhibited and some of their recent applications are dis- cussed. A C++ program to draw the ...

  15. Gas filled detectors

    International Nuclear Information System (INIS)

    Stephan, C.

    1993-01-01

    The main types of gas filled nuclear detectors: ionization chambers, proportional counters, parallel-plate avalanche counters (PPAC) and microstrip detectors are described. New devices are shown. A description of the processes involved in such detectors is also given. (K.A.) 123 refs.; 25 figs.; 3 tabs

  16. Tracheostomy tube - eating

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000464.htm Tracheostomy tube - eating To use the sharing features on ... when you swallow foods or liquids. Eating and Tracheostomy Tubes When you get your tracheostomy tube, or ...

  17. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  18. Heat exchanger tube mounts

    Science.gov (United States)

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  19. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  20. Microstructure Filled Hohlraums

    Energy Technology Data Exchange (ETDEWEB)

    Moore, A. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thomas, C. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reese, T. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-24

    We propose replacing the gas fill in a hohlraum with a low average density, variable uniformity 3D printed structure. This creates a bimodal hohlraum which acts like a vacuum hohlraum initially during the picket, but could protect the capsule from glint or direct illumination, and then once expanded, homogenizes to behave like a variable z gas-fill during peak portion of the drive. This is motivated by a two main aims: 1) reduction of the Au bubble velocity to improve inner beam propagation, and 2) the introduction of a low density, high-Z, x-ray converter to improve x-ray production in the hohlraum and uniformity of the radiation field seen by the capsule.

  1. Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Parra, Amanda [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Russell, Marion [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lee, Wen-Yee [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-05-01

    Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

  2. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  3. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).

    Science.gov (United States)

    Calmette, Leyla; Ibrahim, Firas; Gouin, Isabelle; Horellou, Marie-Hélène; Mazoyer, Élisabeth; Fontenay, Michaela; Flaujac, Claire

    2017-02-01

    Samples transported by pneumatic tube system are submitted to forces of acceleration and deceleration which can affect laboratory parameters. At Cochin hospital, majority of samples of hemostasis, except for platelets tests, are transported by pneumatic tube system. The objective of this study was to evaluate the impact of a pneumatic tube system (PTS) transport compared to hand-delivered transport on samples and to qualify Cochin hospital PTS according to requirements of standard ISO 15189. A bibliographical study was made and showed that pneumatic tube system particularly influences platelets tests. Four citrate tubes were collected in 5 healthy volunteers in the maternity: 2 tubes were transported by PTS and 2 others were hand-delivered to the laboratory. Five coagulation tests were analyzed: prothrombine time (PT), activated partial thromboplastin time (aPTT), factor (F) V, FVIII and platelet closure time with PFA-100TM collagen/epinephrine. For each volunteer, the results obtained by PTS and by hand-delivered transport were compared with formula usually used for biological analysis retake: 2.8 x standard deviation of reproductibility variation coefficient (SH GTA 01, COFRAC). This study did not show an impact of PTS on PT, aPTT, FV and FVIII. For PFA-100TM collagen/epinephrine, we noted an impact on 2/5 volunteers. These results, in agreement with the literature, led to the conclusion that Cochin hospital PTS is in compliance to transport samples for usual coagulation tests except platelet tests. This study allowed to issue French recommendations for PTS transport of hemostasis tubes qualification available on "Groupe français d'hémostase et thrombose" Web site.

  4. Amazon forest ecosystem responses to elevated atmospheric CO2 and alterations in nutrient availability: filling the gaps with model-experiment integration

    Science.gov (United States)

    Hofhansl, Florian; Andersen, Kelly; Fleischer, Katrin; Fuchslueger, Lucia; Rammig, Anja; Schaap, Karst; Valverde-Barrantes, Oscar; Lapola, David

    2016-02-01

    The impacts of elevated CO2 (eCO2) and alterations in nutrient availability on the carbon (C) storage capacity and resilience of the Amazon forest remain highly uncertain. Carbon dynamics are controlled by multiple eco-physiological processes responding to environmental change, but we lack solid experimental evidence, hampering theory development and thus representation in ecosystem models. Here, we present two ecosystem-scale manipulation experiments, to be carried out in the Amazon, that examine tropical ecosystem responses to eCO2 and nutrient addition and thus will elucidate the representation of crucial ecological processes by ecosystem models. We highlight current gaps in our understanding of tropical ecosystem responses to projected global changes in light of the eco-physiological assumptions considered by current ecosystem models. We conclude that a more detailed process-based representation of the spatial (e.g. soil type; plant functional type) and temporal (seasonal and inter-annual variation) diversity of tropical forests is needed to enhance model predictions of ecosystem responses to projected global environmental change.

  5. Development of a multiphase shock tube for energetic materials characterization.

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Jaime N.; Cooper, Marcia A.; Beresh, Steven Jay; Trott, Wayne Merle; Wagner, Justin L.; Kearney, Sean Patrick; Baer, Melvin R.; Pruett, Brian O. M.

    2010-06-01

    A novel multiphase shock tube to study particle dynamics in gas-solid flows has been constructed and tested. Currently, there is a gap in data for flows having particle volume fractions between the dusty and granular regimes. The primary purpose of this new facility is to fill that gap by providing high quality data of shock-particle interactions in flows having dense gas particle volume fractions. Towards this end, the facility aims to drive a shock into a spatially isotropic field, or curtain, of particles. Through bench-top experimentation, a method emerged for achieving this challenging task that involves the use of a gravity-fed contoured particle seeder. The seeding method is capable of producing fields of spatially isotropic particles having volume fractions of about 1 to 35%. The use of the seeder in combination with the shock tube allows for the testing of the impingement of a planar shock on a dense field of particles. The first experiments in the multiphase shock tube have been conducted and the facility is now operational.

  6. Bladder filling variations during concurrent chemotherapy and pelvic radiotherapy in rectal cancer patients: early experience of bladder volume assessment using ultrasound scanner

    International Nuclear Information System (INIS)

    Chang, Jee Suk; Yoon, Hong In; Cha, Hye Jung; Chang, Yoon Sun; Cho, Yeo Na; Keum, Ki Chang; Koom, Woong Sub

    2013-01-01

    To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.

  7. A case study:Finnish ninth grade students’ and their teacher’s views on and experiences in using YouTube video content in English language learning and teaching

    OpenAIRE

    Pigg, E. (Eveliina)

    2017-01-01

    Abstract The purpose of this thesis is to examine how Finnish ninth grade students and their teacher view the use of YouTube in English language learning and teaching and what kind of experiences they have in using it in school and outside the normative school context. The method of the study is ethnographic and it is based on sociocultural and ecological views on language learning. The materials used in the study were ques...

  8. Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

    Science.gov (United States)

    Harikrishnan, S. S.; Kotebavi, Vinod

    2016-09-01

    This paper elaborates on the testing of solar heat pipes using different working fluids, fill ratios and tilt angles. Methanol, Acetone and water are used as working fluids, with fill ratios 25%, 50%, 75% and 100%. Experiments were carried out at 600 and 350 inclinations. Heat pipe condenser section is placed inside a water basin containing 200ml of water. The evaporator section is exposed to sunlight where the working fluid gets heated and it becomes vapour and moves towards the condenser section. In the condenser section the heat is given to the water in the basin and the vapour becomes liquid and comes back to the evaporator section due to gravitational force. Two modes of experiments are carried out: 1) using a parabolic collector and 2) using heat pipe with evacuated tubes. On comparative study, optimum fill ratio is been found to be 25% in every case and acetone exhibited slightly more efficiency than methanol and water. As far as the heat pipe orientation is concerned, 600 inclination of the heat pipe showed better performance than 350

  9. Vibrations of tube arrays in transversal flow

    International Nuclear Information System (INIS)

    Gibert, R.J.; Doyen, R.

    1981-08-01

    In this study the local forces per unit length acting in a tube in a single row and in bundle have been measured. Their modification by a given harmonic motion of the tube itself or of an adjacent tube has been particularly studied. Some complementary experiments have been performed to extend the whirling coefficient tabulation and also to precise the effect of the upstream velocity profile on the whirling critical velocities [fr

  10. Benign gastric filling defect

    Energy Technology Data Exchange (ETDEWEB)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  11. Benign gastric filling defect

    International Nuclear Information System (INIS)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y.

    1979-01-01

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  12. Filled/Eroded Craters

    Science.gov (United States)

    2005-01-01

    14 October 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows rugged terrain in northern Arabia Terra. The circular features are the remains of old meteor impact craters -- either the eroded remnants of the interiors of craters, or the remains of craters that were filled by layered material. The martian bedrock has craters of all sizes and states of erosion interbedded with its layered materials. Location near: 31.4oN, 299.0oW Image width: width: 3 km (1.9 mi) Illumination from: lower left Season: Northern Winter

  13. Fluid Dynamics of Bottle Filling

    Science.gov (United States)

    McGough, Patrick; Gao, Haijing; Appathurai, Santosh; Basaran, Osman

    2011-11-01

    Filling of bottles is a widely practiced operation in a large number of industries. Well known examples include filling of ``large'' bottles with shampoos and cleaners in the household products and beauty care industries and filling of ``small'' bottles in the pharmaceutical industry. Some bottle filling operations have recently drawn much attention from the fluid mechanics community because of the occurrence of a multitude of complex flow regimes, transitions, and instabilities such as mounding and coiling that occur as a bottle is filled with a fluid. In this talk, we present a primarily computational study of the fluid dynamical challenges that can arise during the rapid filling of bottles. Given the diversity of fluids used in filling applications, we consider four representative classes of fluids that exhibit Newtonian, shear-thinning, viscoelastic, and yield-stress rheologies. The equations governing the dynamics of bottle filling are solved either in their full 3D but axisymmetric form or using the slender-jet approximation.

  14. CFD and laboratory analysis of axial cross-flow velocity in porous tube packed with differently structured static turbulence promoters

    Directory of Open Access Journals (Sweden)

    Gaspar Igor

    2015-01-01

    Full Text Available Computational fluid dynamics (CFD was used for modelling flow regime in a porous tube. This tube is an ultrafiltration membrane filter made from zirconium-oxide which is very effective in the separation of stable oil-in-water microemulsions, especially when the tube is filled with static mixer. The results of the CFD analysis were used in the preliminary optimisation of the static mixer’s geometry since it has significant effect the energy requirement of this advanced membrane technology. The self-developed static mixers were tested “in vitro” from the aspect of separation quality and process productivity as well to validate CFD results and to develop a cost effective, green method to recover unmanageable oily wastewaters for sustainable development. In this work the results of computational simulation of the fluid velocity and membrane separation experiments are discussed.

  15. Electroviscous effects in capillary filling of nanochannels

    DEFF Research Database (Denmark)

    Mortensen, Asger; Kristensen, Anders

    2008-01-01

    We theoretically examine the widespread hypothesis of an electroviscous origin of the increase in apparent viscosity observed in recent experiments on capillary filling of nanochannels. Including Debye-layer corrections to the hydraulic resistance, we find that the apparent viscosity reaches...

  16. Preparing for faster filling

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Following the programmed technical stop last week, operators focussed on preparing the machine for faster filling, which includes multibunch injection and a faster pre-cycle phase.   The LHC1 screen shot during the first multibunch injection operation. The LHC operational schedule incorporates a technical stop for preventive maintenance roughly every six weeks of stable operation, during which several interventions on the various machines are carried out. Last week these included the replacement of a faulty magnet in the SPS pre-accelerator, which required the subsequent re-setting of the system of particle extraction and transfer to the LHC. At the end of last week, all the machines were handed back for operation and work could start on accommodating all the changes made into the complex systems in order for normal operation to be resumed. These ‘recovery’ operations continued through the weekend and into this week. At the beginning of this week, operators succeeded in pro...

  17. The effect of coatings on deuterium retention and permeation in aluminum 6061-T6 APT tritium production tubes

    Science.gov (United States)

    Hertz, K. L.; Causey, R. A.; Cowgill, D. F.

    2002-02-01

    The accelerator production of tritium project will utilize spallation neutrons incident on thousands of 3He gas filled metal tubes to produce tritium by way of the exothermic 3He(n,p) 3H reaction. Tritons with energies up to 192 keV and protons with energies up to 576 keV are directly implanted into the tube walls. To minimize tritium retention in the tubes and permeation into the coolant surrounding the tubes, it is desirable to have the implanted tritium migrate back to the inner surface of the tubes and rapidly recombine to be released as T 2 and HT. Aluminum alloy (Al 6061-T6) is the primary candidate material for fabrication of the tubes. Aluminum alloy samples implanted with deuterons and protons to fluences as high as 3×10 22 D (and p)/m 2 were studied. Deuterium retention was measured by mass spectrometry during thermal desorption. Approximately 10% of the implanted deuterium was retained. Copper, nickel and anodized coatings on aluminum alloy were studied as possible methods of reducing retention and permeation of the tritium. In these experiments, the Cu and Ni coatings reduced the retention significantly, whereas retention increased in the anodized coated sample.

  18. Tube bundle vibrations in transversal flow

    International Nuclear Information System (INIS)

    Gibert, R.J.; Sagner, M.

    1978-01-01

    This study gives important information concerning characteristic parameters about lock-in and whirling instability phenomena, in the case of tube arrays. The work is mainly an experimental one though models are also developed: 1) an equilateral pitch bundle (p=1,5 D with D=tube diameter) is tested. Tube damping (epsilon) and first eigenfrequency (f), flow velocity are explored in a large domain. Vibratory level of the tubes are measured and critical points are ploted on the fluidelastic parameters diagram. Several bundles with various usual pitches and arrangements (in line or staggered) are tested. Critical velocities are measured and the whirling instability characteristic coefficient is tabulated. A complementary experiment is made on tube rows with various pitches. This gives valuable informations concerning the look-in domain in VR and A'R diagram. Furthermore this puts in evidence the important effect of a frequency difference between two adjacent tubes on the whirling critical velocity

  19. Why do aged fluorescent tubes flicker?

    Science.gov (United States)

    Plihon, Nicolas; Ferrand, Jérémy; Guyomar, Tristan; Museur, Flavien; Taberlet, Nicolas

    2017-11-01

    Our everyday experience of aged and defective fluorescent tubes or bulbs informs us that they may flicker and emit a clicking sound while struggling to light up. In this article, the physical mechanisms controlling the initial illumination of a functioning fluorescent tube are investigated using a simple and affordable experimental setup. Thermionic emission from the electrodes of the tube controls the startup of fluorescent tubes. The origin of the faulty startup of aged fluorescent tubes is discussed and flickering regimes using functional tubes are artificially produced using a dedicated setup that decreases electron emission by the thermionic effect in a controlled manner. The physical parameters controlling the occurrence of flickering light are discussed, and their temporal statistics are reported.

  20. Remote Field Eddy Curent Signal Modeling for the Gap Measurement of Neighboring Tubes

    Science.gov (United States)

    Jung, H. K.; Lee, D. H.; Lee, Y. S.

    2005-04-01

    The fuel channels in the Canadian Deuterium Uranium (CANDU) reactor consist of the coaxial pressure tube (PT) and the calandria tube (CT). The Liquid injection nozzle (LIN) is cross aligned with the fuel channel to control the reactor by injecting poison. For a safe operation, the gap between the LIN and CT should be maintained in order to prevent a contact of the neighboring tubes. The remote field eddy current (RFEC) method was applied to measure the gap between a nonmagnetic Zircaloy-2 liquid injection nozzle (LIN) and a Zircaloy-2 calandria tube. Under the condition of inserting the RFEC probe into the coaxial tubes and of crossing a LIN above or under the CT, the modeling of a LIN signal is needed to check the possibility of a gap measurement. The Volume Integral Code S/W which covers the axi-symmetric 3D configuration has been very rarely applied to obtain a LIN signal. This problem was solved by assuming a LIN as a flaw which can be described as a complete 3D object. This simulated LIN signal was verified by performing the laboratory experiment. The gap between the LIN and CT can be correlated with the amplitude of the LIN signals in the voltage plane. Typical noises in the fuel channel were the relative constriction, the change in the pressure tube diameter (fill-factor), thickness variation, and so on. These noise signals were simulated by using the modeling and were analyzed by considering their dependency on the phase angle and amplitude of the voltage plane in order to separate the gap signal from them. It could be concluded that the voltage plane analysis of the simulated RFEC signals were effective for obtaining the gap measurement of the neighboring tube.

  1. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  2. CATHENA Code Assessment for Pressure Tube and Calandria Tube Contact Phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyoung Kyoun; Choi, Chul Jin; Choi, Jong Ho [KEPCO-EnC, Daejeon (Korea, Republic of)

    2015-05-15

    Canadian Algorithm for THErmalhydraulic Network Analysis (CATHENA), has been validated against full-scale Contact Boiling Experiments conducted using specific channel power, pressure, and moderator subcooling as pre-test conditions. The pressure tube (PT) and calandria tube (CT) temperatures, the extent of dryout and failures of the pressure tube or the calandria tube (if any) are the outcome of these experiments. Recently, an IAEA International Collaborative Standard Problem (ICSP) to provide contact boiling experimental data to participants for assessing the subcooling requirements for a heated pressure tube, plastically deforming into contact with the calandria tube during a postulated large break LOCA condition has been performed. The CATHENA code assessment results against the experimental data distributed for the ICSP are provided in this paper. The CATHENA code is used to simulate the experiment on pressure tube ballooning conducted at the AECL. The overall code's predictions show good agreements with the experimental data. The contact timing by the pressure tube ballooning is predicted accurately, however, it is found that the code largely underpredict the peak temperature at the pressure tube and the calandria tube. This discrepancy seems to be induced from multi-dimensional flow effects in the water tank. For more accurate calculations, detailed modeling of the water tank is required.

  3. Freezing controlled penetration of molten metals flowing through stainless steel tubes

    International Nuclear Information System (INIS)

    Sienicki, J.J.; Spencer, B.W.; Vetter, D.L.; Wesel, R.H.

    1985-01-01

    The freezing controlled penetration potential of molten metals flowing within stainless steel structure is important to the safety assessment of hypothetical severe accidents in liquid metal reactors. A series of scoping experiments has been performed in which molten stainless steel and nickel at various initial temperatures and driving pressures were injected downward and upward into 6.4 and 3.3 mm ID stainless steel tubes filled with argon gas and initially at room temperature. In all tests, there was no evidence that the solid tube wall was wetted by the molten metals. The penetration phenomena are markedly different for downward versus upward injections. The dependency upon tube orientation is explained in terms of the absence of wetting. Complete plugs were formed in all experiments halting the continued injection of melt. Calculations with a fluid dynamics/heat transfer computer code show that the injected masses limited by plugging are consistent with freezing through the growth of a stable solidified layer (crust) of metal upon the solid tube wall. 23 refs., 5 figs., 2 tabs

  4. A Large Tracking Detector In Vacuum Consisting Of Self-Supporting Straw Tubes

    International Nuclear Information System (INIS)

    Wintz, P.

    2004-01-01

    A novel technique to stretch the anode wire simply by the gas over-pressure inside straw drift tubes reduces the necessary straw weight to an absolute minimum. Our detector will consist of more than 3000 straws filling up a cylindrical tracking volume of 1m diameter and 30cm length. The projected spatial resolution is 200μm. The detector with a total mass of less than 15kg will be operated in vacuum, but will have an added wall thickness of 3mm mylar, only. The detector design, production experience and first results will be discussed

  5. Effect of the inertance tube on the performance of the Stirling type pulse tube refrigerator

    International Nuclear Information System (INIS)

    Hong, Yong Ju; Park, Seong Je; Kim, Hyo Bong; Kim, Yang Hoon; Choi, Young Don

    2002-01-01

    The Pulse Tube Refrigerator(PTR), which has no moving parts at its cold section, is attractive for obtaining higher reliability, simpler construction and lower vibration than in any other small cryocoolers. Commonly used mean to achieve optimum performance of the PTR are orifice or inertance tube. The Stirling type Pulse Tube Refrigerator in the experiments consists of a compressor driven by linear motors, which make pressure waves, a regenerator, a pulse tube with inertance tube, and a buffer. The pressures and temperature are measured to explore the dependency of inertance tube on the performance of the PTR. The results show the dependency of cool-down characteristics, no-load temperature on frequency of operation and inertance tube

  6. Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire

    Directory of Open Access Journals (Sweden)

    Wenchao Liu

    2017-03-01

    Full Text Available Recycled aggregate concrete (RAC is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures.

  7. Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire.

    Science.gov (United States)

    Liu, Wenchao; Cao, Wanlin; Zhang, Jianwei; Wang, Ruwei; Ren, Lele

    2017-03-09

    Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens were subjected to axial compression tests at room temperature and the other six specimens were subjected to axial compression tests after a fire exposure. The main parameters of the specimens include the wall thickness of the steel tube (steel content) and the type of concrete materials. Several parameters as obtained from the experimental results were compared and analyzed, including the load-bearing capacity, deformation capacity, and failure characteristics of the specimens. Meanwhile, rate of loss of bearing capacity of specimens exposed to fire were calculated based on the standards EC4 and CECS28:90. The results show that concrete material has a large influence on the rate of loss of bearing capacity in the case of a relatively lower steel ratio. While steel content has little effect on the rate of loss of bearing capacity of concrete-filled steel tube (CFST) columns after fire, it has a relatively large influence on the loss rate of bearing capacity of the RACFST columns. The loss of bearing capacity of the specimens from the experiment is more serious than that from the calculation. As the calculated values are less conservative, particular attention should be given to the application of recycled aggregate concrete in actual structures.

  8. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  9. Tracheostomy tube - speaking

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000465.htm Tracheostomy tube - speaking To use the sharing features on ... are even speaking devices that can help you. Tracheostomy Tubes and Speaking Air passing through vocal cords ( ...

  10. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  11. Neural Tube Defects

    Science.gov (United States)

    Neural tube defects are birth defects of the brain, spine, or spinal cord. They happen in the ... that she is pregnant. The two most common neural tube defects are spina bifida and anencephaly. In ...

  12. Jejunostomy feeding tube

    Science.gov (United States)

    ... may replace the tube every now and then. Cleaning the Skin Around the J-tube To clean ... this important distinction for online health information and services. Learn more about A.D.A.M.'s editorial ...

  13. Statistical evaluation of metal fill widths for emulated metal fill in parasitic extraction methodology

    Science.gov (United States)

    J-Me, Teh; Noh, Norlaili Mohd.; Aziz, Zalina Abdul

    2015-05-01

    In the chip industry today, the key goal of a chip development organization is to develop and market chips within a short time frame to gain foothold on market share. This paper proposes a design flow around the area of parasitic extraction to improve the design cycle time. The proposed design flow utilizes the usage of metal fill emulation as opposed to the current flow which performs metal fill insertion directly. By replacing metal fill structures with an emulation methodology in earlier iterations of the design flow, this is targeted to help reduce runtime in fill insertion stage. Statistical design of experiments methodology utilizing the randomized complete block design was used to select an appropriate emulated metal fill width to improve emulation accuracy. The experiment was conducted on test cases of different sizes, ranging from 1000 gates to 21000 gates. The metal width was varied from 1 x minimum metal width to 6 x minimum metal width. Two-way analysis of variance and Fisher's least significant difference test were used to analyze the interconnect net capacitance values of the different test cases. This paper presents the results of the statistical analysis for the 45 nm process technology. The recommended emulated metal fill width was found to be 4 x the minimum metal width.

  14. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-12-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at the point where sound is perceived to have maximum loudness, or at the point where the amplitude of the standing wave has maximum value, namely an antinode. An antinode coincides with the position of the tuning fork, beyond the end of the air column, which consequently introduces an end correction. One way to minimize this end correction is to measure the distance between consecutive antinodes.

  15. Nasogastric and feeding tubes. The importance of proper placement.

    Science.gov (United States)

    Gharib, A M; Stern, E J; Sherbin, V L; Rohrmann, C A

    1996-05-01

    The authors' experience in a radiology department suggested to them that there is a wide range of beliefs among practitioners regarding proper placement of nasogastric and feeding tubes. Improper positioning can cause serious problems, as they explain. Indications for different tube positions, complications of incorrect tube placement, and directions for proper positioning are discussed and illustrated.

  16. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  17. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  18. Pulsed Drift Tube Accelerator

    International Nuclear Information System (INIS)

    Faltens, A.

    2004-01-01

    The pulsed drift-tube accelerator (DTA) concept was revived by Joe Kwan and John Staples and is being considered for the HEDP/WDM application. It could be used to reach the full energy or as an intermediate accelerator between the diode and a high gradient accelerator such as multi-beam r.f. In the earliest LBNL HIF proposals and conceptual drivers it was used as an extended injector to reach energies where an induction linac with magnetic quadrupoles is the best choice. For HEDP, because of the very short pulse duration, the DTA could provide an acceleration rate of about 1MV/m. This note is divided into two parts: the first, a design based on existing experience; the second, an optimistic extrapolation. The first accelerates 16 parallel K + beams at a constant line charge density of 0.25(micro) C/m per beam to 10 MeV; the second uses a stripper and charge selector at around 4MeV followed by further acceleration to reach 40 MeV. Both benefit from more compact sources than the present 2MV injector source, although that beam is the basis of the first design and is a viable option. A pulsed drift-tube accelerator was the first major HIF experiment at LBNL. It was designed to produce a 2(micro)s rectangular 1 Ampere C s + beam at 2MeV. It ran comfortably at 1.6MeV for several years, then at lower voltages and currents for other experiments, and remnants of that experiment are in use in present experiments, still running 25 years later. The 1A current, completely equivalent to 1.8A K + , was chosen to be intermediate between the beamlets appropriate for a multi-beam accelerator, and a single beam of, say, 10A, at injection energies. The original driver scenarios using one large beam on each side of the reactor rapidly fell out of favor because of the very high transverse and longitudinal fields from the beam space charge, circa 1MV/cm and 250 kV/cm respectively, near the chamber and because of aberrations in focusing a large diameter beam down to a 1mm radius spot at a

  19. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  20. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  1. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  2. Designing a feedback control algorithm for the tube hydroforming process

    DEFF Research Database (Denmark)

    Endelt, Benny Ørtoft; Cheng, Ming; Zhang, Shihong

    2013-01-01

    feeding). The objective of the present work is to identify a suitable and representative set of state variables and to develop a feedback algorithm enabling online control of material flow throughout the part using only limited/local information regarding the filling of the tool cavity. The filling...... to the dynamic behavior of the system and the numerical tests show that it is possible to control the quality and plastic deformation of the tube. Numerical simulations show that the control system can eliminate both rupture and irreversible wrinkling - which are the two major failure modes in tube hydroforming....

  3. Mechanics of filled carbon nanotubes

    KAUST Repository

    Monteiro, A.O.

    2014-04-01

    The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.

  4. Pelvic bioelectrical impedance measurements to detect rectal filling.

    Science.gov (United States)

    Ratani, R S; Yazaki, E; Maw, A; Pilot, M A; Rogers, J; Williams, N S

    1998-11-01

    Anorectal sensory deficits are an important cause of defecatory disorders and are also a reason for evacuatory difficulties in patients undergoing total anorectal reconstruction. A method to detect rectal filling would be beneficial in such patients. We have investigated the feasibility of detecting rectal filling in vitro and in vivo by measuring changes in pelvic impedance. In vitro, a model of the pelvis was constructed using a cylindrical plastic tank filled with an electrolyte solution (conductivity 3 mS cm(-1)). Conductive Visking tubing representing the rectum was suspended in the tank and incrementally filled with artificial faeces. An impedance meter detected changes in voltage on rectal filling when an alternating current of 2 mA was passed at eight frequencies (4.8 to 612 kHz). In vivo, changes in pelvic bioelectrical impedance upon retrograde and antegrade rectal filling with artificial faeces were evaluated in three pigs, four electrodes being implanted in the pelvis. Impedance measurements accurately detected 'rectal' volume changes in vitro (n = 10, p < 0.0001; Kruskal Wallis), but not in vivo (n = 68, p = 0.48; Kruskal Wallis). This was probably due to extreme sensitivity of the detecting device to movement, a problem that needs to be resolved before this technique could be used in man.

  5. Radioactive waste slurry dehydrating and drum filling device

    International Nuclear Information System (INIS)

    Ichihashi, Toshio; Abe, Kazuaki; Hasegawa, Akira

    1981-01-01

    Purpose: To obtain a device for simultaneously filling and dehydrating radioactive waste in a waste can without the necessity of a special device for dehydration. Constitution: This device includes a radioactive waste storage tank, a pump for supplying the waste from the tank to a can, a drain tube having a filter at the lower end and installed displaceable in the axial direction of the can, and a drain pump. The slurry stored in the radioactive waste storage tank is supplied by the pump to the can, and the feedwater in the slurry is removed by another pump through a drain pipe having a filter which does not pass solid content from the can. Accordingly, as the slurry is filled in the can, the feedwater contained therein is removed. Consequently, it can simultaneously dehydrate and fill the dehydrated waste in the can. (Yoshihara, H.)

  6. The effect of tube-support interaction on the dynamic response of heat exchanger tubes

    International Nuclear Information System (INIS)

    Shin, Y.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1977-01-01

    To avoid detrimental tube vibration in heat exchangers, resonant conditions and instabilitites must be avoided, and/or peak dynamic amplitudes must not exceed allowable limits. In attempting a theoretical analysis, questions arise as to the effects of tube/support interaction on tube vibrational characteristics (i.e. resonant frequencies, modes, damping) and response amplitude. As a part of ANL's Flow-Induced Vibration Program in support of the Clinch River Breeder Reactor Plant (CRBRP) steam generator design activity, tube/support interaction experiments are being performed not only to gain the insight into the dynamic behavior of CRBRP steam generator tubes, but also to provide the basis for developing design guidance. Test results were compared with anaytical results based on multispan tube with 'knife-edge' supports at the support locations. (Auth.)

  7. Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

    Science.gov (United States)

    Ha, Junhyoung; Park, Frank C; Dupont, Pierre E

    2017-02-01

    Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

  8. Radiopacity of root filling materials

    International Nuclear Information System (INIS)

    Beyer-Olsen, E.M.

    1983-01-01

    A method for measuring the radiopacity of root filling materials is described. Direct measurements were made of the optic density values of the materials in comparison with a standard curve relating optic density to the thickness of an aluminium step wedge exposed simultaneously. By proper selection of film and conditions for exposure and development, it was possible to obtain a near-linear standard curve which added to the safety and reproducibility of the method. The technique of radiographic assessment was modified from clinical procedures in evaluating the obturation in radiographs, and it was aimed at detecting slits or voids between the dental wall and the filling material. This radiographic assessment of potensial leakage was compared with actual in vitro lekage of dye (basic fuchsin) into the roots of filled teeth. The result of the investigation show that root filling materials display a very wide range of radiopacity, from less than 3 mm to more than 12 mm of aluminium. It also seem that tooth roots that appear to be well obturated by radiographic evaluation, stand a good chance of beeing resistant to leakage in vitro, and that the type of filling material rather than its radiographic appearance, determines the susceptibility of the filled tooth to leakage in vitro. As an appendix the report contains a survey of radiopaque additives in root filling materials

  9. Lunar Lava Tube Sensing

    Science.gov (United States)

    York, Cheryl Lynn; Walden, Bryce; Billings, Thomas L.; Reeder, P. Douglas

    1992-01-01

    Large (greater than 300 m diameter) lava tube caverns appear to exist on the Moon and could provide substantial safety and cost benefits for lunar bases. Over 40 m of basalt and regolith constitute the lava tube roof and would protect both construction and operations. Constant temperatures of -20 C reduce thermal stress on structures and machines. Base designs need not incorporate heavy shielding, so lightweight materials can be used and construction can be expedited. Identification and characterization of lava tube caverns can be incorporated into current precursor lunar mission plans. Some searches can even be done from Earth. Specific recommendations for lunar lava tube search and exploration are (1) an Earth-based radar interferometer, (2) an Earth-penetrating radar (EPR) orbiter, (3) kinetic penetrators for lunar lava tube confirmation, (4) a 'Moon Bat' hovering rocket vehicle, and (5) the use of other proposed landers and orbiters to help find lunar lava tubes.

  10. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  11. Nonlinear Fabry-Perot filled with CS2 and nitrobenzene

    International Nuclear Information System (INIS)

    Bischofberger, T.; Shen, Y.R.

    1979-01-01

    We have studied the characteristics of nonlinear Fabry-Perot filled with Kerr liquids CS 2 and nitorbenzene and found excellent agreement between theory and experiment. The transient behavior due to cavity-field buildup is discussed

  12. The pulse tube and the pendulum.

    Science.gov (United States)

    Swift, G W; Backhaus, S

    2009-11-01

    An inverted pulse tube in which gravity-driven convection is suppressed by acoustic oscillations is analogous to an inverted pendulum that is stabilized by high-frequency vibration of its pivot point. Gravity acts on the gas density gradient arising from the end-to-end temperature gradient in the pulse tube, exerting a force proportional to that density gradient, tending to cause convection when the pulse tube is inverted. Meanwhile, a nonlinear effect exerts an opposing force proportional to the square of any part of the density gradient that is not parallel to the oscillation direction. Experiments show that convection is suppressed when the pulse-tube convection number N(ptc)=omega(2)a(2)DeltaT/T(avg)/[g(alphaD sin theta-L cos theta)] is greater than 1 in slender tubes, where omega is the radian frequency of the oscillations, a is their amplitude, DeltaT is the end-to-end temperature difference, T(avg) is the average absolute temperature, g is the acceleration of gravity, L is the length of the pulse tube and D is its diameter, alpha is about 1.5, and the tip angle theta ranges from 90 degrees for a horizontal tube to 180 degrees for an inverted tube. Theory suggests that the temperature dependence should be DeltaT/T(avg) instead of DeltaT/T(avg).

  13. Application of a finite element method for computing grazing incidence wave structure in an impedance tube - Comparison with experiment. [for duct liner aeroacoustic design

    Science.gov (United States)

    Lester, H. C.; Parrott, T. L.

    1979-01-01

    The acoustic performance of a liner specimen, in a grazing incidence impedance tube, is analyzed using a finite element method. The liner specimen was designed to be a locally reacting, two-degree-of-freedom type with the resistance and reactance provided by perforated facesheets and compartmented cavities. Measured and calculated wave structures are compared for both normal and grazing incidence from 0.3 to 1.2 kHz. A finite element algorithm was incorporated into an optimization loop in order to predict liner grazing incidence impedance from measured SWR and null position data. Results suggest that extended reaction effects may have been responsible for differences between normal and grazing incidence impedance estimates.

  14. A numerical method for acoustic oscillations in tubes

    Science.gov (United States)

    Gary, John M.

    1988-01-01

    A numerical method to obtain the neutral curve for the onset of acoustic oscillations in a helium-filled tube is described. Such oscillations can cause a serious heat loss in the plumbing associated with liquid helium dewars. The problem is modelled by a second-order, ordinary differential eigenvalue problem for the pressure perturbation. The numerical method to find the eigenvalues and track the resulting points along the neutral curve is tailored to this problem. The results show that a tube with a uniform temperature gradient along it is much more stable than one where the temperature suddenly jumps from the cold to the hot value in the middle of the tube.

  15. A large area transition radiation detector for the NOMAD experiment

    Science.gov (United States)

    Bassompierre, G.; Bermond, M.; Berthet, M.; Bertozzi, T.; Détraz, C.; Dubois, J.-M.; Dumps, L.; Engster, C.; Fazio, T.; Gaillard, G.; Gaillard, J.-M.; Gouanère, M.; Manola-Poggioli, E.; Mossuz, L.; Mendiburu, J.-P.; Nédélec, P.; Palazzini, E.; Pessard, H.; Petit, P.; Petitpas, P.; Placci, A.; Sillou, D.; Sottile, R.; Valuev, V.; Verkindt, D.; Vey, H.; Wachnik, M.

    1998-02-01

    A transition radiation detector to identify electrons at 90% efficiency with a rejection factor against pions of 10 3 on an area of 2.85 × 2.85 m 2 has been constructed for the NOMAD experiment. Each of its 9 modules includes a 315 plastic foil radiator and a detector plane of 176 vertical straw tubes filled with a xenon-methane gas mixture. Details of the design, construction and operation of the detector are given.

  16. A large area transition radiation detector for the NOMAD experiment

    CERN Document Server

    Bassompierre, Gabriel; Berthet, M; Bertozzi, T; Détraz, C; Dubois, J M; Dumps, Ludwig; Engster, Claude; Fazio, T; Gaillard, G; Gaillard, Jean-Marc; Gouanère, M; Manola-Poggioli, E; Mossuz, L; Mendiburu, J P; Nédélec, P; Palazzini, E; Pessard, H; Petit, P; Petitpas, P; Placci, Alfredo; Sillou, D; Sottile, R; Valuev, V Yu; Verkindt, D; Vey, H; Wachnik, M

    1997-01-01

    A transition radiation detector to identify electrons at 90% efficiency with a rejection factor against pions of 10 3 on an area of 2.85 × 2.85 m 2 has been constructed for the NOMAD experiment. Each of its 9 modules includes a 315 plastic foil radiator and a detector plane of 176 vertical straw tubes filled with a xenon-methane gas mixture. Details of the design, construction and operation of the detector are given.

  17. Manual tube welding torch

    International Nuclear Information System (INIS)

    Kiefer, J.H.; Smith, D.J.

    1981-01-01

    In a welding torch which fits over a tube intermediate the ends thereof for welding the juncture between the tube and a boss on the back side of a tube plate, a split housing encloses a tungsten electrode, a filler wire duct and a fiber optic bundle arranged to observe the welding process. A shielding gas duct is provided in the housing. A screw is provided for setting electrode/work distance. Difficult remote tube welding operations can be performed with the apparatus. (author)

  18. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  19. Wound tube heat exchanger

    Science.gov (United States)

    Ecker, Amir L.

    1983-01-01

    What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

  20. Sapphire tube pressure vessel

    Science.gov (United States)

    Outwater, John O.

    2000-01-01

    A pressure vessel is provided for observing corrosive fluids at high temperatures and pressures. A transparent Teflon bag contains the corrosive fluid and provides an inert barrier. The Teflon bag is placed within a sapphire tube, which forms a pressure boundary. The tube is received within a pipe including a viewing window. The combination of the Teflon bag, sapphire tube and pipe provides a strong and inert pressure vessel. In an alternative embodiment, tie rods connect together compression fittings at opposite ends of the sapphire tube.

  1. Fuel nozzle tube retention

    Energy Technology Data Exchange (ETDEWEB)

    Cihlar, David William; Melton, Patrick Benedict

    2017-02-28

    A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

  2. Innovative phase shifter for pulse tube operating below 10 K

    Science.gov (United States)

    Duval, Jean-Marc; Charles, Ivan; Daniel, Christophe; André, Jérôme

    2016-09-01

    Stirling type pulse tubes are classically based on the use of an inertance phase shifter to optimize their cooling power. The limitations of the phase shifting capabilities of these inertances have been pointed out in various studies. These limitations are particularly critical for low temperature operation, typically below about 50 K. An innovative phase shifter using an inertance tube filled with liquid, or fluid with high density or low viscosity, and separated by a sealed metallic diaphragm has been conceived and tested. This device has been characterized and validated on a dedicated test bench. Operation on a 50-80 K pulse tube cooler and on a low temperature (below 8 K) pulse tube cooler have been demonstrated and have validated the device in operation. These developments open the door for efficient and compact low temperature Stirling type pulse tube coolers. The possibility of long life operation has been experimentally verified and a design for space applications is proposed.

  3. Removal of root filling materials.

    LENUS (Irish Health Repository)

    Duncan, H.F. Chong, B.S.

    2011-05-01

    Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.

  4. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  5. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  6. Limiting the Accidental Pressure Drop in NIF Beam Tubes

    International Nuclear Information System (INIS)

    Garcia, M

    2000-01-01

    This report summarizes the use of a one-dimensional model of a time-dependent compressible flow condition to validate the results from a more sophisticated three-dimensional model. The flow conditions consist of the sudden decompression of a pressurized tube joined to an evacuated sphere, where the tube also has a leak to external atmosphere that is triggered open at a given pressure difference below sea-level pressure. This flow model is used to calculate conditions in a NIF beam tube if an internal vacuum barrier fails, and to calculate how the size and timing of an opening to external atmosphere changes tube pressure. Decompression of a NIF beam tube is a potential safety hazard since the tube could collapse if the tube pressure is reduced below the buckling limit. To prevent this from occurring, each pressurized section includes a rupture panel which is designed to open to external atmosphere at a given pressure difference. The inrush of external atmosphere through the rupture panel fills both the tube and the vacuum drawing on it, and in this way the pressure drop in the tube is quickly limited and reversed. In summary, the results from the 1D model indicate that the 3-D calculations are accurate and reasonable

  7. Prediction of the energy-absorption capability of composite tubes

    Science.gov (United States)

    Farley, Gary L.; Jones, Robert M.

    1992-01-01

    A method of predicting the crack-related energy-absorption capability of composite tubes is presented. The method is based upon a phenomenological model of the crushing process exhibited by continuous-fiber-reinforced tubes. A finite element method is used to model the crushing process. The analysis is compared with experiments on Kevlar-epoxy and graphite-epoxy tubes. Reasonable agreement is obtained between the analysis and experiment.

  8. Agir pour l’égalité filles-garçons au collège Working for gender equality in the school: between individual experience and institutional demand, an uncertain encounter

    Directory of Open Access Journals (Sweden)

    Nicole Guenneuguès

    2011-10-01

    Full Text Available Le présent article rend compte d’une recherche conduite pour éclairer les obstacles à la prise en compte de la problématique du genre au sein de l’école, alors qu’elle fait explicitement partie de ses missions. Pour ce faire, j’ai choisi de m’intéresser à la minorité de professeur-e-s préoccupé-e-s par les questions « filles garçons » dans leurs pratiques professionnelles en collège. En appui sur la théorie de l’expérience sociale développée par F. Dubet (1994 et sa thèse d’un déclin du programme institutionnel (ibid. 2002, j’ai tenté de comprendre le sens de leur action. La dizaine d’entretiens compréhensifs réalisée ne constitue qu’une première ébauche mais il ressort de leur analyse que l’action de cette minorité doit peu aux incitations de l’institution scolaire. La place occupée par l’histoire personnelle de l’actrice et de l’acteur, tant pour légitimer son engagement que pour orienter son action, apparaît comme un puissant obstacle à l’émergence d’une dynamique collective.This article presents research conducted to clarify the obstacles to taking gender into account in the school – a theme which is actually one of its stated goals. To this aim, I chose to focus on the minority of teachers, women and men, engaged in "girls/boys" issues in their work in high school. Building on the theory of "social experience" developed by F. Dubet (1994 and his thesis of a "decline of the institutional program" (ibid, 2002, I attempted to understand the sense of their actions. The dozen comprehensive interviews conducted constitute only an initial step. But it emerges from analyzing them that the practices of this minority owe little to the promptings of the educational institution. Each individual’s personal history seems to be the principal cognitive resource to justify and guide that person’s actions. The weight of that personal history would appear to strongly block any group

  9. Chest Tube Thoracostomy

    Science.gov (United States)

    ... in the space around the lungs (called a pleural effusion) . A chest tube may also be needed when a patient has ... or chest CT are also done to evaluate pleural fluid. If the X-ray shows a need for a chest tube to drain fluid or air, the procedure is ...

  10. The reconstruction of tracks with the drift tubes in the muon spektrometers of the neutrino experiment OPERA; Die Spurrekonstruktion fuer das Driftroehren-Myon-Spektrometer des Neutrino-Experiments OPERA

    Energy Technology Data Exchange (ETDEWEB)

    Wonsak, B.S.

    2007-11-15

    In this thesis the reconstruction of tracks within the OPERA muon spectrometer is described as well as parts of the simulation software concerning the drift tubes. A method minimising the {chi}{sup 2} of the tracks is used for the fit, which is supported by liklyhood considerations during the pattern recognition. An analytical description of the time to distance relation for the OPERA drift tubes is introduced to be used in the fit. For simulated events of cosmics a resolution of 410{+-}4 {mu}m and an efficiency of more that 93% has been acquired. For real cosmic data from the OPERA detector a resolution o 374{+-}3 {mu}m and an efficiency of up to 84% has been reached. The acquired angular resolution of 1,2 mrad is sufficient to achieve a momentum resolution of 25% up to momentums of 25 GeV. (orig.)

  11. Ventricular tachycardia following tube thoracotomy.

    Science.gov (United States)

    Hibbert, Benjamin; Lim, Toon Wei; Hibbert, Rebecca; Green, Martin; Gollob, Michael H; Davis, Darryl R

    2010-10-01

    Arrhythmias provoked by tube thoracotomy are a rare complication. We report a ventricular tachycardia after chest tube insertion for a device-related pneumothorax. Sinus rhythm was restored only by removal of the chest tube and insertion of a pliable pleural drain. Identification of the chest tube as an arrhythmic trigger following tube thoracotomy is essential in definitive management of refractory arrhythmias.

  12. Assessment of RELAP5/MOD3.1 with the LSTF SB-SG-06 experiment simulating a steam generator tube rupture transient

    Energy Technology Data Exchange (ETDEWEB)

    Seul, K.W.; Bang, Y.S.; Lee, S.; Kim, H.J. [Korea Inst. of Nuclear Safety, Taejon (Korea, Republic of)

    1996-09-01

    The objective of the present work is to identify the predictability of RELAP5/MOD3.1 regarding thermal-hydraulic behavior during a steam generator tube rupture (SGTR). To evaluate the computed results, LSTF SB-SG-06 test data simulating the SGTR that occurred at the Mihama Unit 2 in 1991 are used. Also, some sensitivity studies of the code change in RELAP5, the break simulation model, and the break valve discharge coefficient are performed. The calculation results indicate that the RELAP5/MOD3.1 code predicted well the sequence of events and the major phenomena during the transient, such as the asymmetric loop behavior, reactor coolant system (RCS) cooldown and heat transfer by natural circulation, the primary and secondary system depressurization by the pressurizer auxiliary spray and the steam dump using the intact loop steam generator (SG) relief valve, and so on. However, there are some differences from the experimental data in the number of the relief valve cycling in the affected SG, and the flow regime of the hot leg with the pressurizer, and the break flow rates. Finally, the calculation also indicates that the coolant in the core could remain in a subcooled state as a result of the heat transfer caused by the natural circulation flow even if the reactor coolant pumps (RCPs) turned off and that the affected SG could be properly isolated to minimize the radiological release after the SGTR.

  13. [Tuberculosis Contact Investigation: Eight Years of Experience with the QuantiFERON-TB®Gold In-Tube in Lower Saxony, Germany].

    Science.gov (United States)

    Scharlach, M; Brakensiek, K

    2017-04-01

    Since the beginning of the 21 st century, beside tuberculin skin tests (TST) and chest X-rays, interferon-gamma release assays (IGRA) have become available for diagnosing latent tuberculosis infection. In 2006, the Governmental Institute of Public Health of Lower Saxony (NLGA) established the IGRA in its laboratory, using the QuantiFERON-TB ® Gold In-Tube (QFT). A cohort of 19 309 contact persons who were investigated during contact tracing by local public health departments (LPHD) was analyzed. Within 3 years, 75% of LPHDs in Lower Saxony established the QFT for tuberculosis contact tracing. Between 2007 and 2014 the percentage of contact persons≥15 years of age with initial TST declined from 65.1 to 1.7%. For contact personsSaxony, not least because of the modified recommendations for environmental contact tracing in tuberculosis of the German Central Committee against Tuberculosis (DZK). Higher specificity of the QFT and thus fewer X-rays, omission of the second visit for interpreting the TST, and the inappropriate package size of the TST for smaller LPHDs are further arguments in favor for the QFT. But unspecific use of the QFT must be avoided; otherwise, the value of the QFT result declines. The increasing number of contact persons with migration background and the changing countries of origin are a challenge for all who are involved in tuberculosis contact tracing. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  15. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s...... technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  16. A flow-through amperometric sensor based on dialysis tubing and free enzyme reactors

    NARCIS (Netherlands)

    Bohm, S.; Pijanowska, D.G.; Pijanowska, D.; Olthuis, Wouter; Bergveld, Piet

    2001-01-01

    A generic flow-through amperometric microenzyme sensor is described, which is based on semi-permeable dialysis tubing carrying the sample to be analyzed. This tubing (300 μm OD) is led through a small cavity, containing the working and reference electrode. By filling this cavity with a few μl of an

  17. Liquid Oscillations in a U-Tube

    Science.gov (United States)

    Aguilar, Horacio Munguía; Maldonado, Rigoberto Franco; Navarro, Luis Barba

    2018-01-01

    In hydrostatics, pressure measurement with U-gauges and their relationship to density is a well-known experiment. Very little is studied or experimented with the dynamics of the movement of a liquid in a U-tube probably due to its theoretical complexity but, after all, it is a simple damped oscillating system. In this paper we present a relatively…

  18. External quality assurance with dried tube specimens (DTS) for point-of-care syphilis and HIV tests: experience in an indigenous populations screening programme in the Brazilian Amazon.

    Science.gov (United States)

    Benzaken, Adele Schwartz; Bazzo, Maria Luiza; Galban, Enrique; Pinto, Ione Conceição Pereira; Nogueira, Christiane Lourenço; Golfetto, Lisléia; Benzaken, Nina Schwartz; Sollis, Kimberly A; Mabey, David; Peeling, Rosanna W

    2014-02-01

    The availability of point-of-care (POC) tests for infectious diseases has revolutionised the provision of healthcare for remote rural populations without access to laboratories. However, quality assurance for POC tests has been largely overlooked. We have evaluated the use and stability of dry tube specimens (DTS) for External Quality Assurance (EQA) for HIV and syphilis screening in remote indigenous populations in the Amazon region of Brazil. All healthcare workers (HCWs) participating in the community-screening were trained. We used HIV and syphilis DTS panels developed by the reference laboratory, containing samples with negative and positive results at different antibody concentrations, for both infections. DTS panels were distributed to HCWs in the communities for reconstitution and testing using POC HIV and syphilis tests. The results of testing were sent to the reference laboratory for marking and remedial action taken where necessary. In total 268 HCWs tested 1607 samples for syphilis and 1608 samples for HIV. Results from HCWs showed a concordance rate of 90% for syphilis and 93% for HIV (κ coefficients of 0.74 and 0.78, respectively) with reference laboratories. Most false negatives were in samples of very low antibody concentration. DTS syphilis specimens produced the expected results after storage at 2-8°C or at 18-24°C for up to 3 weeks. The results show that POC tests for syphilis and HIV give valid results in environments where traditional tests do not work, but errors in the interpretation of POC test results were identified by the EQA programme using DTS. EQA using DTS can help to improve the quality of screening programmes using POC tests in remote regions.

  19. Silicone Gel-Filled Breast Implants

    Science.gov (United States)

    ... and Prosthetics Breast Implants Silicone Gel-Filled Breast Implants Share Tweet Linkedin Pin it More sharing options ... it Email Print Description: Silicone gel-filled breast implants have a silicone outer shell that is filled ...

  20. Spectrally Compatible Iterative Water Filling

    Science.gov (United States)

    Verlinden, Jan; Bogaert, Etienne Vanden; Bostoen, Tom; Zanier, Francesca; Luise, Marco; Cendrillon, Raphael; Moonen, Marc

    2006-12-01

    Until now static spectrum management has ensured that DSL lines in the same cable are spectrally compatible under worst-case crosstalk conditions. Recently dynamic spectrum management (DSM) has been proposed aiming at an increased capacity utilization by adaptation of the transmit spectra of DSL lines to the actual crosstalk interference. In this paper, a new DSM method for downstream ADSL is derived from the well-known iterative water-filling (IWF) algorithm. The amount of boosting of this new DSM method is limited, such that it is spectrally compatible with ADSL. Hence it is referred to as spectrally compatible iterative water filling (SC-IWF). This paper focuses on the performance gains of SC-IWF. This method is an autonomous DSM method (DSM level 1) and it will be investigated together with two other DSM level-1 algorithms, under various noise conditions, namely, iterative water-filling algorithm, and flat power back-off (flat PBO).

  1. Spectrally Compatible Iterative Water Filling

    Directory of Open Access Journals (Sweden)

    Cendrillon Raphael

    2006-01-01

    Full Text Available Until now static spectrum management has ensured that DSL lines in the same cable are spectrally compatible under worst-case crosstalk conditions. Recently dynamic spectrum management (DSM has been proposed aiming at an increased capacity utilization by adaptation of the transmit spectra of DSL lines to the actual crosstalk interference. In this paper, a new DSM method for downstream ADSL is derived from the well-known iterative water-filling (IWF algorithm. The amount of boosting of this new DSM method is limited, such that it is spectrally compatible with ADSL. Hence it is referred to as spectrally compatible iterative water filling (SC-IWF. This paper focuses on the performance gains of SC-IWF. This method is an autonomous DSM method (DSM level 1 and it will be investigated together with two other DSM level-1 algorithms, under various noise conditions, namely, iterative water-filling algorithm, and flat power back-off (flat PBO.

  2. Atmospheres in a Test Tube

    Science.gov (United States)

    Claudi, R.; Erculiani, M. S.; Giro, E.; D'Alessandro, M.; Galletta, G.

    2013-09-01

    The "Atmosphere in a Test Tube" project is a laboratory experiment that will be able to reproduce condition of extreme environments by means of a simulator. These conditions span from those existing inside some parts of the human body to combinations of temperatures, pressures, irradiation and atmospheric gases present on other planets. In this latter case the experiments to be performed will be useful as preliminary tests for both simulation of atmosphere of exoplanets and Solar System planets and Astrobiology experiments that should be performed by planetary landers or by instruments to be launched in the next years. In particular at INAF Astronomical Observatory of Padova Laboratory we are approaching the characterization of extrasolar planet atmospheres taking advantage by innovative laboratory experiments with a particular focus on low mass Neptunes and Super earths and low mass M dwarfs primaries.

  3. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  4. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  5. QENS investigation of filled rubbers

    CERN Document Server

    Triolo, A; Desmedt, A; Pieper, J K; Lo Celso, F; Triolo, R; Negroni, F; Arrighi, V; Qian, H; Frick, B

    2002-01-01

    The polymer segmental dynamics is investigated in a series of silica-filled rubbers. The presence of inert fillers in polymers greatly affects the mechanical and physical performance of the final materials. For example, silica has been proposed as a reinforcing agent of elastomers in tire production. Results from quasielastic neutron scattering and Dynamic Mechanical Thermal Analysis (DMTA) measurements are presented on styrene-ran-butadiene rubber filled with silica. A clear indication is obtained of the existence of a bimodal dynamics, which can be rationalized in terms of the relaxation of bulk rubber and the much slower relaxation of the rubber adsorbed on the filler surface. (orig.)

  6. Accidental Decannulation OF TRACHEOSTOMY TUBES - Case Series.

    Science.gov (United States)

    Omokanye, H K; Dunmade, A D; Segun-Busari, S; Afolabi, O A; Habeeb, O G; Adegboye, M B; Alabi, B S

    2016-01-01

    Tracheostomy tube (TT) is usually removed in a planned manner once the patient ceases to have the condition that necessitated the procedure. Accidental decannulation or extubation refers to inadvertent removal of tracheostomy tube out of the stoma. It could prove fatal in an otherwise stable patient. We review a variety of unexpected and often-overlooked causes of accidental decannulation with suggestions on preventive measures. We therefore present three cases of accidental decannulation of tracheostomy tubes in order to report our experiences in the management of the condition. Accidental decannulation occurs both in hospitalized and patient on home care of their tracheostomy tubes. Reduction in neck circumference due to weight loss predisposes to accidental decannulation, which could be prevented by suturing the flange to the skin.

  7. The Type of Container and Filling Method Have Consequences on Semen Quality in Swine AI Doses

    Directory of Open Access Journals (Sweden)

    Iulian Ibanescu

    2016-05-01

    Full Text Available The automatic filling of semen doses for artificial insemination in swine shows economic advantages over the old-style, manual filling. However, no data could be found regarding the impact, if any, of this packing method on semen quality. This study aimed to compare two types of containers for boar semen, namely the automatically-filled tube and the manually-filled bottle, in terms of preserving the quality of boar semen. Five ejaculates from five different boars were diluted with the same extender and then divided in two aliquots. First aliquot was loaded in tubes filled by an automatic machine while the second was loaded manually in special plastic bottles. The semen was stored in liquid state at 17°C, regardless of the type of container and examined daily, for five days of storage by means of a computer-assisted sperm analyzer. Both types of containers maintained the semen within acceptable values, but after five days of storage significant differences (p<0.05 between the container types were observed in terms of all selected kinetic parameters. The tube showed better values for sperm motility and velocity, while the bottle showed superior values for straightness and linearity of sperm movement. The automatically-filled tubes offered better sperm motility in every day of the study. Given the fact that sperm motility is still the main criterion in assessing semen quality in semen production centers, the main conclusion of this study is that the automatic loading in tubes is superior and recommended over the old-style manual loading in bottles.

  8. Circumferential cracking of steam generator tubes

    International Nuclear Information System (INIS)

    Karwoski, K.J.

    1997-04-01

    On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, open-quote Circumferential Cracking of Steam Generator Tubes.close-quote GL 95-03 was issued to obtain information needed to verify licensee compliance with existing regulatory requirements regarding the integrity of steam generator tubes in domestic pressurized-water reactors (PWRs). This report briefly describes the design and function of domestic steam generators and summarizes the staff's assessment of the responses to GL 95-03. The report concludes with several observations related to steam generator operating experience. This report is intended to be representative of significant operating experience pertaining to circumferential cracking of steam generator tubes from April 1995 through December 1996. Operating experience prior to April 1995 is discussed throughout the report, as necessary, for completeness

  9. A miniature high repetition rate shock tube

    Science.gov (United States)

    Tranter, R. S.; Lynch, P. T.

    2013-09-01

    A miniature high repetition rate shock tube with excellent reproducibility has been constructed to facilitate high temperature, high pressure, gas phase experiments at facilities such as synchrotron light sources where space is limited and many experiments need to be averaged to obtain adequate signal levels. The shock tube is designed to generate reaction conditions of T > 600 K, P < 100 bars at a cycle rate of up to 4 Hz. The design of the apparatus is discussed in detail, and data are presented to demonstrate that well-formed shock waves with predictable characteristics are created, repeatably. Two synchrotron-based experiments using this apparatus are also briefly described here, demonstrating the potential of the shock tube for research at synchrotron light sources.

  10. Large-square coordinate detector based on streamer tubes

    International Nuclear Information System (INIS)

    Aul'chenko, V.M.; Bajbusinov, B.O.; Lel'chuk, M.Yu.; Nomerotskij, A.B.; Chegodaev, A.V.; Chilingarov, A.G.

    1988-01-01

    The KMD-2 and KEDR muon detector system for experiments at VEPP storage rings is described. The KMD-2 muon system includes two layers of streamer tubes separated by the magnet yoke iron. Each layer consists of 8 octant-units. The tubes inside the unit are seriesly connected into batches of 4 for inner units (tube diameter is 20 mm) and into batches of 8 for outer units (tube diameter is 40 mm). The total tube number constitute 656, the chammel number being 128. The KEDR muon sytem for the VEPP-4 stirage ring will consist of 5 thousands of streamer tubes 40 mm in-dameter and 4-5 m long connected into batches of 4 tubes. Flowsheet of electronic channel is presented. One time channel permits to get 12x20 mm spatial resolution at detector square of 40x20000 mm. 3 refs.; 1 fig

  11. Integrating YouTube into the nursing curriculum.

    Science.gov (United States)

    Sharoff, Leighsa

    2011-08-17

    Nurse educators need to be innovative, stimulating, and engaging as they teach future nursing professionals. The use of YouTube in nursing education classes provides an easy, innovative, and user-friendly way to engage today's nursing students. YouTube presentations can be easily adapted into nursing courses at any level, be it a fundamentals course for undergraduate students or a theoretical foundations course for graduate students. In this article I will provide information to help educators effectively integrate YouTube into their course offerings. I will start by reviewing the phenomenon of social networking. Next I will discuss challenges and strategies related to YouTube learning experiences, after which I will share some of the legal considerations in using YouTube. I will conclude by describing how to engage students via YouTube and current research related to YouTube.

  12. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  13. Tube Alinement for Machining

    Science.gov (United States)

    Garcia, J.

    1984-01-01

    Tool with stepped shoulders alines tubes for machining in preparation for welding. Alinement with machine tool axis accurate to within 5 mils (0.13mm) and completed much faster than visual setup by machinist.

  14. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1982-04-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1980. Tube defects occurred at 38% of the 97 reactors surveyed. This is a marginal improvement over 1979 when defects occurred at 41% of the reactors. The number of failed tubes was also lower, 0.14% of the tubes in service in 1980 compared with 0.20% of those in service in 1979. Analysis of the causes of these failures indicates that stress corrosion cracking was the leading failure mechanism. Reactors that used all-volatile treatment of secondary water, with or without full-flow condensate demineralization since start-up showed the lowest incidence of corrosion-related defects

  15. Ear tube insertion

    Science.gov (United States)

    ... mastoiditis) or the brain, or that damages nearby nerves Injury to the ear after sudden changes in ... does not heal after the tube falls out. Most of the time, these problems DO NOT last long. They also ...

  16. Tube Feeding Troubleshooting Guide

    Science.gov (United States)

    ... the diameter is measured in units known as French sizes, or “Fr”; a low profile tube also ... your quality of life. You are encouraged to speak with your physician, dietitian, home care company, or ...

  17. Vibro-impact responses of a tube with tube--baffle interaction

    International Nuclear Information System (INIS)

    Shin, Y.S.; Sass, D.E.; Jendrzejczyk, J.A.

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments

  18. Magnesium tube hydroforming

    Energy Technology Data Exchange (ETDEWEB)

    Liewald, M.; Pop, R. [Institute for Metal Forming Technology (IFU), Stuttgart (Germany)

    2008-04-15

    Magnesium alloys reveal a good strength-to-weight ratio in the family of lightweight metals and gains potential to provide up to 30% mass savings compared to aluminium and up to 75 % compared to steel. The use of sheet magnesium alloys for auto body applications is however limited due to the relatively low formability at room temperature. Within the scope of this paper, extruded magnesium tubes, which are suitable for hydroforming applications, have been investigated. Results obtained at room temperature using magnesium AZ31 tubes show that circumferential strains are limited to a maximal value of 4%. In order to examine the influence of the forming temperature on tube formability, investigations have been carried out with a new die set for hot internal high pressure (IHP) forming at temperatures up to 400 C. Earlier investigations with magnesium AZ31 tubes have shown that fractures occur along the welding line at tubes extruded over a spider die, whereby a non-uniform expansion at bursting with an elongation value of 24% can be observed. A maximum circumferential strain of approx. 60% could be attained when seamless, mechanically pre-expanded and annealed tubes of the same alloy have been used. The effect of annealing time on materials forming properties shows a fine grained structure for sufficient annealing times as well as deterioration with a large increase at same time. Hence, seamless ZM21 tubes have been used in the current investigations. With these tubes, an increased tensile fracture strain of 116% at 350 C is observed as against 19% at 20 C, obtained by tensile testing of milled specimens from the extruded tubes. This behaviour is also seen under the condition of tool contact during the IHP forming process. To determine the maximum circumferential strain at different forming temperatures and strain rates, the tubes are initially bulged in a die with square cross-section under plane stress conditions. Thereafter, the tubes are calibrated by using an

  19. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  20. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  1. Filling of charged cylindrical capillaries

    NARCIS (Netherlands)

    Das, S.; Chanda, Sourayon; Eijkel, Jan C.T.; Tas, Niels Roelof; Chakraborty, Suman; Mitra, Sushanta K.

    2014-01-01

    We provide an analytical model to describe the filling dynamics of horizontal cylindrical capillaries having charged walls. The presence of surface charge leads to two distinct effects: It leads to a retarding electrical force on the liquid column and also causes a reduced viscous drag force because

  2. Evaluation of reliability of EC inspection of VVER SG tubes

    International Nuclear Information System (INIS)

    Stanic, D.

    2001-01-01

    Evaluation of eddy current data collected during inspection of VVER steam generators is very complex task because of numerous parameters which have affect on eddy current signals. That was the reason that recently ago INETEC has started related scientific project in order to evaluate the reliability of eddy current (EC) inspection of VVER steam generator (SG) tubing. In the scope of project the following objectives will be investigated: 1. Determination of POD (Probability of detection) of various types degradation cracks, where their basic parameters are variables (basic parameters are depth, length, width, orientation, number) on three different sets of tubes (clean ideal tubes, tubes with pilgering, tubes electroplated with copper) 2. Sizing quality (accuracy, repeatability) (same data sets as defined in 1.) 3. Effect of fill factor on POD and sizing quality. 4. Effect of tube bends on POD and sizing quality. 5. Effect of other tube geometry variations on POD and sizing quality (tube ovality, transition zone region, expanded (rolled) part of tube, dents, dings). Investigation will start with bobbin probe technique which is the most used technique for general purpose VVER tube examination. Since INETEC is the only world company which successfully developed and applied rotating probe technique for VVER SG tubes, scope of the project will be extended on rotating probe technique utilizing 'pancake' and 'point' coil. Method reliability will be investigated first on the huge set of EDM notches representing various defect morphologies and simulating different factors, and the second part will be investigated on sets of degradation defects obtained by artificial corrosion. In the scope of the project the measures for enhancing the method reliability have to be determined. This considers the proper definition of parameters of examination system, as well as establishment of the suitable analysis procedures. This article presents the temporary results of the first part of

  3. Dynamics of tubes in fluid with tube-baffle interaction

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1983-09-01

    Three series of tests are performed to evaluate the effects of tube to tube-support-plate (TSP) clearance on tube dynamic characteristics and instability phenomena for tube arrays in crossflow. Test results show that, for relatively large clearances, tubes may possess TSP-inactive modes in which the tubes rattle inside some of the tube-support-plate holes, and that the natural frequencies of TSP-inactive modes are lower than those of TSP-active modes, in which the support plates provide knife-edge type support. Tube response characteristics associated with TSP-inactive modes are sensitive to tube-to-TSP clearance, TSP thickness, excitation amplitude, tube alignment, and the fluid inside the clearance. In addition, tube response is intrinsically nonlinear, with the dominance of TSP-inactive or TSP-active modes depending on the magnitudes of different system parameters. In general, such a system is difficult to model; only a full-scale test can provide all the necessary characteristics. A tube array supported by TSPs with relatively large clearances may be subjected to dynamic instability in some of the TSP-inactive modes; tube response characteristics and impact forces on TSPs for a tube row are studied in detail in this report. Tube displacements associated with the instability of a TSP-inactive mode are small; however, impacts of the tube against TSPs may result in significant damage in a relatively short time. 52 figures

  4. A model for the performance of a vertical tube condenser in the presence of noncondensable gases

    Energy Technology Data Exchange (ETDEWEB)

    Guentay, A.D.S.

    1995-09-01

    Some proposed vertical tube condensers are designed to operate at high noncondensable fractions, which warrants a simple model to predict their performance. Models developed thus far are usually non self-contained as they require the specification of the wall temperature to predict the local condensation rate. The present model attempts to fill this gap by addressing the secondary side heat transfer as well. Starting with momentum balance which includes the effect of interfacial shear stress, a Nusselt-type algebraic equation is derived for the film thickness as a function of flow and geometry parameters. The heat and mass transfer analogy relations are then invoked to deduce the condensation rate of steam onto the tube wall. Lastly, the heat transfer to the secondary side is modelled to include cooling by forced, free or mixed convection flows. The model is used for parametric simulations to determine the impact on the condenser performance of important factors such as the inlet gas fraction, the mixture inlet flowrate, the total pressure, and the molecular weight of the noncondensable gas. The model performed simulations of some experiments with pure steam and air-steam mixtures flowing down a vertical tube. The model predicts the data quite well.

  5. 3D Laboratory Measurements of Forces, Flows, and Collimation in Arched Flux Tubes

    Science.gov (United States)

    Haw, Magnus; Bellan, Paul

    2016-10-01

    Fully 3D, vector MHD force measurements from an arched, current carrying flux tube (flux rope) are presented. The experiment consists of two arched plasma-filled flux ropes each powered by a capacitor bank. The two loops are partially overlapped, as in a Venn diagram, and collide and reconnect during their evolution. B-field data is taken on the lower plasma arch using a 54 channel B-dot probe. 3D volumetric data is acquired by placing the probe at 2700 locations and taking 5 plasma shots at each location. The resulting data set gives high resolution (2cm, 10ns) volumetric B-field data with high reproducibility (deviation of 3% between shots). Taking the curl of the measured 3D B-field gives current densities (J) in good agreement with measured capacitor bank current. The JxB forces calculated from the data have a strong axial component at the base of the current channel and are shown to scale linearly with axial gradients in current density. Assuming force balance in the flux tube minor radius direction, we infer near-Alfvenic axial flows from the footpoint regions which are consistent with the measured axial forces. Flux tube collimation is observed in conjunction with these axial flows. These dynamic processes are relevant to the stability and dynamics of coronal loops. Supported provided by NSF, AFOSR.

  6. Evaluation of reaction gap-filling accuracy by randomization.

    Science.gov (United States)

    Latendresse, Mario; Karp, Peter D

    2018-02-14

    Completion of genome-scale flux-balance models using computational reaction gap-filling is a widely used approach, but its accuracy is not well known. We report on computational experiments of reaction gap filling in which we generated degraded versions of the EcoCyc-20.0-GEM model by randomly removing flux-carrying reactions from a growing model. We gap-filled the degraded models and compared the resulting gap-filled models with the original model. Gap-filling was performed by the Pathway Tools MetaFlux software using its General Development Mode (GenDev) and its Fast Development Mode (FastDev). We explored 12 GenDev variants including two linear solvers (SCIP and CPLEX) for solving the Mixed Integer Linear Programming (MILP) problems for gap filling; three different sets of linear constraints were applied; and two MILP methods were implemented. We compared these 13 variants according to accuracy, speed, and amount of information returned to the user. We observed large variation among the performance of the 13 gap-filling variants. Although no variant was best in all dimensions, we found one variant that was fast, accurate, and returned more information to the user. Some gap-filling variants were inaccurate, producing solutions that were non-minimum or invalid (did not enable model growth). The best GenDev variant showed a best average precision of 87% and a best average recall of 61%. FastDev showed an average precision of 71% and an average recall of 59%. Thus, using the most accurate variant, approximately 13% of the gap-filled reactions were incorrect (were not the reactions removed from the model), and 39% of gap-filled reactions were not found, suggesting that curation is still an important aspect of metabolic-model development.

  7. Experimental squash load of concrete-filled thin welded cold formed ...

    African Journals Online (AJOL)

    étudiés sont: La hauteur du tube variable de 50 à 500 mm, le matériau de remplissage et l'effet de la localisation des soudures ... design recommendations for the strength evaluation of slender composite columns with thin-walled steel sections. Results of tests6 conducted on 27 concrete-filled steel tubular columns were ...

  8. Computer program TMOC for calculating of pressure transients in fluid filled piping networks

    International Nuclear Information System (INIS)

    Siikonen, T.

    1978-01-01

    The propagation of a pressure wave in fluid filles tubes is significantly affected by the pipe wall motion and vice versa. A computer code TMOC (Transients by the Method of Characteristics) is being developed for the analysis of the coupled fluid and pipe wall transients. Because of the structural feedback, the pressure can be calculated more accurately than in the programs commonly used. (author)

  9. Jaw cysts - filling or no filling after enucleation? A review.

    Science.gov (United States)

    Ettl, Tobias; Gosau, Martin; Sader, Robert; Reichert, Torsten E

    2012-09-01

    Jaw cysts are common lesions in the oral and maxillofacial region. Enucleation of the lesions and primary closure of the defects, the so-called "cystectomy", has evolved as the treatment of choice. In order to reduce infections and to accelerate bone regeneration, different types of bone grafts are increasingly investigated for defect filling. The present review reflects the most recent studies using autogenous, allogenic, xenogenic and alloplastic bone grafts and compares the results to current investigations about conservative cyst enucleation without using any filling materials. Relevant studies with significant patient sample sizes were electronically searched in PubMed and Medline. Simple cyst enucleation and blood clot healing show low complication rates and sufficient bone regeneration even in large defects. Prospective randomized trials comparing the additional use of filling materials to the "cystectomy" are rare. Currently available data do not indicate the superiority of additional bone grafts. Enucleation of jaw cysts and primary closure without bone substitutes remains "state of the art" in most cases. Copyright © 2011 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    ... tube feeding; PEG tube care; Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding ... pump (includes a feeding bag, drip chamber, roller clamp, ...

  11. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  12. Formability of Micro-Tubes in Hydroforming

    Science.gov (United States)

    Hartl, Christoph; Anyasodor, Gerald; Lungershausen, Joern

    2011-05-01

    Micro-hydroforming is a down-scaled metal forming process, based on the expansion of micro-tubes by internal pressurization within a die cavity. The objective of micro-hydroforming is to provide a technology for the economic mass production of complex shaped hollow micro-components. Influence of size effects in metal forming processes increases with scaling down of metal parts. Investigations into the change in formability of micro-tubes due to metal part scaling down constituted an important subject within the conducted fundamental research work. Experimental results are presented, concerning the analysis of the formability of micro-tubes made from stainless steel AISI 304 with an outer diameter of 800 μm and a wall thickness of 40 μm. An average ratio of tube wall thickness to grain size of 1.54 of up to 2.56 was analyzed. Miniaturised mechanical standard methods as well as bulge tests with internal hydrostatic pressurization of the tubular specimens were applied to analyze the influence of size-dependent effects. A test device was developed for the bulge experiments which enabled the pressurization of micro-tubes with internal pressures up to 4000 bar. To determine the attainable maximum achievable expansion ratio the tubes were pressurized in the bulge tests with increasing internal pressure until instability due to necking and subsequent bursting occurred. Comparisons with corresponding tests of macro-tubes, made from the here investigated material, showed a change in formability of micro-tubes which was attributed to the scaling down of the hydroforming process. In addition, a restricted applicability of existing theoretical correlations for the determination of the maximum pressure at bursting was observed for down-scaled micro-hydroforming.

  13. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  14. Narratives From YouTube

    Directory of Open Access Journals (Sweden)

    Mikael Quennerstedt

    2013-10-01

    Full Text Available The aim of this paper is to explore what is performed in students’ and teachers’ actions in physical education practice in terms of “didactic irritations,” through an analysis of YouTube clips from 285 PE lessons from 27 different countries. Didactic irritations are occurrences that Rønholt describes as those demanding “didactic, pedagogical reflections and discussions, which in turn could lead to alternative thinking and understanding about teaching and learning.” Drawing on Barad’s ideas of performativity to challenge our habitual anthropocentric analytical gaze when looking at educational visual data, and using narrative construction, we also aim to give meaning to actions, relations, and experiences of the participants in the YouTube clips. To do this, we present juxtaposing narratives from teachers and students in terms of three “didactic irritations”: (a stories from a track, (b, stories from a game, and (c, stories from a bench. The stories re-present events-of-moving in the data offering insights into embodied experiences in PE practice, making students’ as well as teachers’ actions in PE practice understandable.

  15. Post-test calculations of out-of-pile single rod burst experiments with Argentine ZRY-4 tubes using SSYST codes system

    International Nuclear Information System (INIS)

    Nassini, H.; Meyder, R.

    1988-11-01

    The calculations were performed with SSYST-3 code system. The experiments have been carried out with shortened REBEKA simulators. The main goal was to verify whether the model for describing the Zircaloy cladding deformation and rupture at high temperatures (NORA2 model) is able to predict the Argentine cladding material behaviour under such conditions. A good agreement between experimental results and model predictions was found in the range of temperatures from 700 to 850 0 C (in α phase and first half of α+β transition phase). There were some discrepances at higher temperatures, probably due to the strong influence of heating rate on material properties. According to the results of these post-test calculations, it can be concluded that NORA2 model is able to well describe the Argentine Zircaloy cladding deformation and rupture under LOCA conditions, because there was a good agreement in the range of burst (ballooning) temperatures which are expected in this type of accident. (orig./HP) [de

  16. An investigation on mechanical property of commercial copper tube to aluminium 2025 tube plate by FWTPET process

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, S., E-mail: kannan.dgl201127@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand 826004 (India); Senthil Kumaran, S., E-mail: sskumaran@ymail.com [Research and Development Center, Department of Mechanical Engineering, RVS Educational Trust' s Group of Institutions, RVS School of Engineering and Technology, Dindigul, Tamilnadu 624005 (India); Kumaraswamidhas, L.A., E-mail: lakdhas1978@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand 826004 (India)

    2016-07-05

    Frictional welding of tube to tube plate by external tool (FWTPET) posses wide spread industrial in mass production process for joint similar and dissimilar materials. Frictional welding process allows welding of some materials that are exceptionally hard to fusion weld. The good quality joint between the tube and tube plate is achieved by selecting the proper process parameter. In this present research, the frictional welding is done between the Aluminium 2025 tube plate and commercial copper tube possessing a clearance fit of 0.1 mm between tube and hole. In this study, two conditions were considered while handing out this experiment. The condiction1 is tube without holes [WOH] and condition 2 is tube with holes [WH] on the tube circumference. In total, twenty seven work pieces have been considered separately for both conditions and the mechanical property such as compression strength and hardness value has been measured for the both set of work piece in two conditions to analysis the joint strength of the welding process. Taguchi L{sub 27} orthogonal array has been used in this process to identify the process parameter which influences the joint strength of the welded samples. ANOVA method is used to calculate the percentage of contribution by each process parameter which influences the better joint strength. Genetic algorithm is used to authenticate the outcome obtained from the both experimental value and optimization value. Scanning Electron Microscope (SEM) and Energy-dispersive X-ray analysis (EDX) has been performed to probe microstructures and chemical compositions for work piece without holes which has higher mechanical property. - Highlights: • FWTPET for dissimilar metals commercial copper tube and Al 2025 tube plate. • The hardness value for tube without holes are 180.988 Hv. • The compression strength for tube without holes are 376.05 MPa. • SEM confirm heat production is done to melt parent metal by diffusion process. • EDX prove no trace

  17. Flow and oscillations in collapsible tubes: Physiological applications ...

    Indian Academy of Sciences (India)

    ... by partial venous collapse, and in arteries, which exhibit self-excited oscillations (Korotkov sounds) when compressed by a blood-pressure cuff. Laboratory experiments are frequently conducted in a Starling resistor, a finite length of flexible tube, mounted between two rigid tubes and contained in a pressurised chamber.

  18. The Rijke Tube - A Thermo-acoustic Device

    Indian Academy of Sciences (India)

    converts heat into acoustic energy (sound). Rijke's original interest in the phenomenon appears to have been from the point of view of musical acoustics. He first experimented with a vertical tube which had a piece of fine metallic gauze stretched across it in the lower part of the tube. The gauze was heated until red hot by a ...

  19. Electron accelerating unit for streak image tubes

    Indian Academy of Sciences (India)

    Keywords. High-speed photography; streak camera; Monte Carlo; electro-optical devices. 1. Introduction. Streak cameras are among the most valuable instruments for recording ultrafast phenomena in laser-driven inertial confinement fusion (ICF) experiments, and streak image tubes (SITs) are a core part of streak cameras.

  20. Sealed drift tube cosmic ray veto counters

    Energy Technology Data Exchange (ETDEWEB)

    Rios, R., E-mail: rrios@lanl.go [Idaho State University, Pocatello, ID 83209 (United States); Tatar, E. [Idaho State University, Pocatello, ID 83209 (United States); Bacon, J.D.; Bowles, T.J.; Hill, R.; Green, J.A.; Hogan, G.E.; Ito, T.M.; Makela, M.; Morris, C.L.; Mortenson, R.; Pasukanics, F.E.; Ramsey, J.; Saunders, A.; Seestrom, S.J.; Sondheim, W.E.; Teasdale, W. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Saltus, M. [Sloan Enterprises, NC (United States); Back, H.O.; Cottrell, C.R. [North Carolina State University, Raleigh, NC 27695 (United States)

    2011-05-01

    We describe a simple drift tube counter that has been used as a cosmic ray veto for the UCNA experiment, a first-ever measurement of the neutron beta-asymmetry using ultra-cold neutrons. These detectors provide an inexpensive alternative to more conventional scintillation detectors for large area cosmic ray anticoincidence detectors.

  1. When to Remove a Chest Tube.

    Science.gov (United States)

    Novoa, Nuria M; Jiménez, Marcelo F; Varela, Gonzalo

    2017-02-01

    Despite the increasing knowledge about the pleural physiology after lung resection, most practices around chest tube removal are dictated by personal preferences and experience. This article discusses recently published data on the topic and suggests opportunities for further investigation and future improvements. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Steam generator tube vibration study

    International Nuclear Information System (INIS)

    Enderlin, W.I.

    1986-01-01

    Chemical cleaning has been proposed to remove magnetite buildup in some pressurized water reactor steam generators. The US Nuclear Regulatory Commission (NRC) has expressed concern that such cleaning would combine with the tube denting caused by magnetite formation to enlarge tube/tube support plate clearances, increasing the level of flow-induced vibrations that could lead to unacceptably high tube wear and failure rates. In support of NRC, the Pacific Northwest Laboratory investigated whether such increased clearances would exacerbate tube fretting wear. Using a full-length scale model of a steam generator tube bundle, flow tests were conducted at an instrumented location through clearances representing as-built and post-cleaned tube conditions. Test results indicated little potential for increased tube wear as a result of chemical cleaning, under normal operating conditions at tube support locations similar to that tested

  3. Process and device for detecting and localizing leaks in a tube bundle heat exchanger when it is stopped

    International Nuclear Information System (INIS)

    Germain, J.L.; Jeanneteau, E.; Loisy, F.

    1986-01-01

    The device can be used to detect the tubes presenting leaks in a tube bundle exchanger of a light water reactor. This device comprises a feeding point to fill the secondary part of the exchanger, in which the tubes are immersed, with a pressure mixture of vector gas (air) and helium. It has also a feeding point to establish in the tube a sweeping air flow. An analysis apparatus, such as a spectrograph, measures the helium content of air at the outlet of each tube [fr

  4. Boiler tube failure prevention in fossil fired boilers

    International Nuclear Information System (INIS)

    Townsend, R.D.

    1993-01-01

    It is the common experience of power generating companies worldwide that the main causes of forced outages on power plant are those due to boiler tube failures on fossil units. The main reason for the large number of failures are the severe environmental conditions in fossil boilers as the effects of stress, temperature, temperature gradients, corrosion, erosion and vibration combine to produce degradation of the tube steel. Corrosion by oxidation, by combustion products and by impure boiler water can significantly reduce the tube wall thickness and result in failure of a tube many years before its designed service life. Errors can also occur in the design manufacturer, storage, operation, and maintenance of boiler tubing and the wrong material installed in a critical location can lead to premature failure. Altogether, experts in the US and UK, from many different disciplines, have identified seven broad categories of boiler tube failure mechanisms. 1 tab., 2 figs

  5. Charge balancing fill rate monitor

    International Nuclear Information System (INIS)

    Rothman, J.L.; Blum, E.B.

    1995-01-01

    A fill rate monitor has been developed for the NSLS storage rings to allow machine tuning over a very large dynamic range of beam current. Synchrotron light, focused on a photodiode, produces a signal proportional to the beam current. A charge balancing circuit processes the diode current, creating an output signal proportional to the current injected into the ring. The unit operates linearly over a dynamic range of 120 dB and can resolve pulses of injected beam as small as 1 μA

  6. Misdirected minitracheostomy tube

    Directory of Open Access Journals (Sweden)

    Ajmer Singh

    2017-01-01

    Full Text Available We report a patient who after an uneventful coronary artery bypass graft surgery and left ventricular aneurysmorrhaphy developed intracerebral hemorrhage and subsequently required minitracheostomy. Chest X-ray showed misdirected minitracheostomy tube facing upward toward the laryngeal opening which was repositioned using bronchoscope.

  7. Thoughts of accelerator tubes

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators

  8. Thoughts of accelerator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Larson, J D

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators.

  9. Eustachian Tube Dysfunction

    Science.gov (United States)

    ... When it is inflated, the balloon opens a pathway for mucus and air to flow through the tube. This can help it function properly. FDA warning The U.S. Food and Drug Administration (FDA) advises against the use of ear candles. ...

  10. Tube-dwelling invertebrates

    NARCIS (Netherlands)

    Hölker, Franz; Vanni, Michael J.; Kuiper, Jan J.; Meile, Christof; Grossart, Hans Peter; Stief, Peter; Adrian, Rita; Lorke, Andreas; Dellwig, Olaf; Brand, Andreas; Hupfer, Michael; Mooij, Wolf M.; Nützmann, Gunnar; Lewandowski, Jörg

    2015-01-01

    There is ample evidence that tube-dwelling invertebrates such as chironomids significantly alter multiple important ecosystem functions, particularly in shallow lakes. Chironomids pump large water volumes, and associated suspended and dissolved substances, through the sediment and thereby compete

  11. Chest tube insertion

    Science.gov (United States)

    ... of your chest cavity. This is called the pleural space. It is done to allow your lungs to fully expand. ... pneumothorax ) Fluid buildup in the chest (called a pleural ... in the esophagus (the tube that allows food to go from the mouth ...

  12. An advanced tube wear and fatigue workstation to predict flow induced vibrations of steam generator tubes

    International Nuclear Information System (INIS)

    Gay, N.; Baratte, C.; Flesch, B.

    1997-01-01

    Flow induced tube vibration damage is a major concern for designers and operators of nuclear power plant steam generators (SG). The operating flow-induced vibrational behaviour has to be estimated accurately to allow a precise evaluation of the new safety margins in order to optimize the maintenance policy. For this purpose, an industrial 'Tube Wear and Fatigue Workstation', called 'GEVIBUS Workstation' and based on an advanced methodology for predictive analysis of flow-induced vibration of tube bundles subject to cross-flow has been developed at Electricite de France. The GEVIBUS Workstation is an interactive processor linking modules as: thermalhydraulic computation, parametric finite element builder, interface between finite element model, thermalhydraulic code and vibratory response computations, refining modelling of fluid-elastic and random forces, linear and non-linear dynamic response and the coupled fluid-structure system, evaluation of tube damage due to fatigue and wear, graphical outputs. Two practical applications are also presented in the paper; the first simulation refers to an experimental set-up consisting of a straight tube bundle subject to water cross-flow, while the second one deals with an industrial configuration which has been observed in some operating steam generators i.e., top tube support plate degradation. In the first case the GEVIBUS predictions in terms of tube displacement time histories and phase planes have been found in very good agreement with experiment. In the second application the GEVIBUS computation showed that a tube with localized degradation is much more stable than a tube located in an extended degradation zone. Important conclusions are also drawn concerning maintenance. (author)

  13. Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development

    Energy Technology Data Exchange (ETDEWEB)

    Pschirer, James [Alstom Power Inc., Windsor, CT (United States); Burgess, Joshua [Alstom Power Inc., Windsor, CT (United States); Schrecengost, Robert [Alstom Power Inc., Windsor, CT (United States)

    2017-08-16

    Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), has completed the project “Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development” under U.S. Department of Energy (DOE) Award Number DE-FE0024076. This project was part of DOE’s Novel Crosscutting Research and Development to Support Advanced Energy Systems program. AUSC Tube Membrane Panel Development was a two and one half year project to develop and verify the manufacturability and serviceability of welded tube membrane panels made from high performance materials suitable for the AUSC steam cycles, defined as high pressure steam turbine inlet conditions of 700-760°C (1292-1400°F) and 24.5-35MPa (3500-5000psi). The difficulty of this challenge lies in the fact that the membrane-welded construction imposes demands on the materials that are unlike any that exist in other parts of the boiler. Tube membrane panels have been designed, fabricated, and installed in boilers for over 50 years with relatively favorable experience when fabricated from carbon and Cr-Mo low alloy steels. The AUSC steam cycle requires membrane tube panels fabricated from materials that have not been used in a weldment with metal temperatures in the range of 582-610°C (1080-1130°F). Fabrication materials chosen for the tubing were Grade 92 and HR6W. Grade 92 is a creep strength enhanced ferritic Cr-Mo alloy and HR6W is a high nickel alloy. Once the materials were chosen, GE performed the engineering design of the panels, prepared shop manufacturing drawings, and developed manufacturing and inspection plans. After the materials were purchased, GE manufactured and inspected the tube membrane panels, determined if post fabrication heat treatment of the tube membrane panels was needed, performed pre- and post-weld heat treatment on the Grade 92 panels, conducted final nondestructive inspection of any heat treated tube membrane panels, conducted destructive inspection of the completed tube

  14. Filling behaviour of wood plastic composites

    Science.gov (United States)

    Duretek, I.; Lucyshyn, T.; Holzer, C.

    2017-01-01

    Wood plastic composites (WPC) are a young generation of composites with rapidly growing usage within the plastics industry. The advantages are the availability and low price of the wood particles, the possibility of partially substituting the polymer in the mixture and sustainable use of the earth’s resources. The current WPC products on the market are to a large extent limited to extruded products. Nowadays there is a great interest in the market for consumer products in more use of WPC as an alternative to pure thermoplastics in injection moulding processes. This work presents the results of numerical simulation and experimental visualisation of the mould filling process in injection moulding of WPC. The 3D injection moulding simulations were done with the commercial software package Autodesk® Moldflow® Insight 2016 (AMI). The mould filling experiments were conducted with a box-shaped test part. In contrast to unfilled polymers the WPC has reduced melt elasticity so that the fountain flow often does not develop. This results in irregular flow front shapes in the moulded part, especially at high filler content.

  15. Rice Husk Filled Polymer Composites

    Directory of Open Access Journals (Sweden)

    Reza Arjmandi

    2015-01-01

    Full Text Available Natural fibers from agricultural wastes are finding their importance in the polymer industry due to the many advantages such as their light weight, low cost and being environmentally friendly. Rice husk (RH is a natural sheath that forms around rice grains during their growth. As a type of natural fiber obtained from agroindustrial waste, RH can be used as filler in composites materials in various polymer matrices. This review paper is aimed at highlighting previous works of RH filled polymer composites to provide information for applications and further research in this area. Based on the information gathered, application of RH filled composites as alternative materials in building and construction is highly plausible with both light weight and low cost being their main driving forces. However, further investigations on physical and chemical treatment to further improve the interfacial adhesion with polymeric matrix are needed as fiber-polymer interaction is crucial in determining the final composite properties. Better understanding on how the used polymer blends as the matrix and secondary fillers may affect the properties would provide interesting areas to be explored.

  16. Domain walls and spacetime-filling branes

    NARCIS (Netherlands)

    Bergshoeff, E; Wess, J; Ivanov, EA

    1999-01-01

    We discuss branes with one transversal direction (domain walls) and no transversal direction (spacetime-filling branes). In particular, we briefly discuss a relationship between spacetime-filling branes and superstring theories with sixteen supercharges.

  17. Instrumented tube burns: theoretical and experimental observations

    Energy Technology Data Exchange (ETDEWEB)

    Yarrington, Cole Davis [Los Alamos National Laboratory; Obrey, Stephen J [Los Alamos National Laboratory; Foley, Timothy J [Los Alamos National Laboratory; Son, Steven F [Los Alamos National Laboratory

    2009-01-01

    The advent of widely available nanoscale energetic composites has resulted in a flurry of novel applications. One of these applications is the use of nanomaterials in energetic compositions. In compositions that exhibit high sensitivity to stimulus, these materials are often termed metastable intermolecular composites (MIC). More generally, these compositions are simply called nanoenergetics. Researchers have used many different experimental techniques to analyze the various properties of nanoenergetic systems. Among these various techniques, the confined tube burn is a simple experiment that is capable of obtaining much data related to the combustion of these materials. The purpose of this report is to review the current state of the confined tube burn experiment, including the drawbacks of the technique and possible remedies. As this report is intended to focus on the specific experimental technique, data from many different energetic materials, and experimental configurations will be presented. The qualitative and quantitative data that can be gathered using confined tube burn experiments include burning rates, total impulse, pressure rise rate, and burning rate differences between different detector types. All of these measurements lend insight into the combustion properties and mechanisms of specific nanoenergetics. Finally, certain data indicates a more complicated flow scenario which may need to be considered when developing burn tube models.

  18. Pressure loss characteristics of LSTF steam generator heat-transfer tubes. Pressure loss increase due to tube internal instruments

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro

    1994-11-01

    The steam generator of the Large-Scale Test Facility (LSTF) includes 141 heat-transfer U-tubes with different lengths. Six U-tubes among them are furnished with 15 or 17 probe-type instruments (conduction probe with a thermocouple; CPT) protuberant into the primary side of the U-tubes. Other 135 U-tubes are not instrumented. This results in different hydraulic conditions between the instrumented and non-instrumented U-tubes with the same length. A series of pressure loss characteristics tests was conducted at a test apparatus simulating both types of U-tube. The following pressure loss coefficient (K CPT ) was reduced as a function of Reynolds number (Re) from these tests under single-phase water flow conditions. K CPT =0.16 5600≤Re≤52820, K CPT =60.66xRe -0.688 2420≤Re≤5600, K CPT =2.664x10 6 Re -2.06 1371≤Re≤2420. The maximum uncertainty is 22%. By using these results, the total pressure loss coefficients of full length U-tubes were estimated. It is clarified that the total pressure loss of the shortest instrumented U-tube is equivalent to that of the middle-length non-instrumented U-tube and also that a middle-length instrumented U-tube is equivalent to the longest non-instrumented U-tube. Concludingly. it is important to take account of the CPT pressure loss mentioned above in estimation of fluid behavior at the non-instrumented U-tubes either by using the LSTF experiment data from the CPT-installed U-tubes or by using any analytical codes. (author)

  19. Vertical Scan-Conversion for Filling Purposes

    OpenAIRE

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  20. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  1. Rubens Flame-Tube Demonstration.

    Science.gov (United States)

    Ficken, George W.; Stephenson, Francis C.

    1979-01-01

    Investigates and explains the phenomenon associated with Rubens flame-tube demonstration, specifically the persistance of flames at regular intervals along the tube for few minutes after the gas is turned off. (GA)

  2. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  3. Transmission efficiency of neutron guide tube with alignment errors

    International Nuclear Information System (INIS)

    Kawabata, Yuji; Suzuki, Masatoshi; Sakamoto, Masanobu; Harami, Taikan; Takahashi, Hidetake; Onishi, Nobuaki

    1990-01-01

    The experimental studies on the neutron transmission efficiencies of neutron guide tubes were carried out by using thermal neutrons from the JAERI electron linac. The neutron guide tube facility on a large scale have been planned on the reconstructed JRR-3 in JAERI. The neutron efficiencies of the 1/10 scale neutron guide tube, which is 2 mm width and 1.8 m length, with and without appreciable alignment errors were studied to evaluate the efficiencies of the planned ones. Calculated results by the Neutron Guide Tube Analysis Code 'NEUGT' were also assessed by these neutron experiments. The experimental results agree well with the calculated results by 'NEUGT' even with alignment errors. From this experimental study, the efficiency of the planned neutron guide tubes is estimated to be good enough for the neutron beam experiments. (author)

  4. Vacuum filling of complex microchannels with liquid metal.

    Science.gov (United States)

    Lin, Yiliang; Gordon, Olivia; Khan, M Rashed; Vasquez, Neyanel; Genzer, Jan; Dickey, Michael D

    2017-09-12

    This paper describes the utilization of vacuum to fill complex microchannels with liquid metal. Microchannels filled with liquid metal are useful as conductors for soft and stretchable electronics, as well as for microfluidic components such as electrodes, antennas, pumps, or heaters. Liquid metals are often injected manually into the inlet of a microchannel using a syringe. Injection can only occur if displaced air in the channels has a pathway to escape, which is usually accomplished using outlets. The positive pressure (relative to atmosphere) needed to inject fluids can also cause leaks or delamination of the channels during injection. Here we show a simple and hands-free method to fill microchannels with liquid metal that addresses these issues. The process begins by covering a single inlet with liquid metal. Placing the entire structure in a vacuum chamber removes the air from the channels and the surrounding elastomer. Restoring atmospheric pressure in the chamber creates a positive pressure differential that pushes the metal into the channels. Experiments and a simple model of the filling process both suggest that the elastomeric channel walls absorb residual air displaced by the metal as it fills the channels. Thus, the metal can fill dead-ends with features as small as several microns and branched structures within seconds without the need for any outlets. The method can also fill completely serpentine microchannels up to a few meters in length. The ability to fill dense and complex geometries with liquid metal in this manner may enable broader application of liquid metals in electronic and microfluidic applications.

  5. 7 CFR 58.923 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.923 Section 58.923 Agriculture... Procedures § 58.923 Filling containers. (a) The filling of small containers with product shall be done in a sanitary manner. The containers shall not contaminate or detract from the quality of the product in any way...

  6. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  7. Internal Accident Report: fill it out!

    CERN Multimedia

    2012-01-01

    It is important to report all accidents, near-misses and dangerous situations so that they can be avoided in the future.   Reporting these events allows the relevant services to take appropriate action and implement corrective and preventive measures. It should be noted that the routing of the internal accident report was recently changed to make sure that the people who need to know are informed. Without information, corrective action is not possible. Without corrective action, there is a risk that the events will recur. As soon as you experience or see something amiss, fill out an internal accident report! If you have any questions the HSE Unit will be happy to answer them. Contact us at safety-general@cern.ch. The HSE Unit

  8. NEI You Tube Videos: Amblyopia

    Science.gov (United States)

    ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  9. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  10. Devices for investigation and intervention on steam generators tubes bundles

    International Nuclear Information System (INIS)

    Launay, J.P.; Sort, M.

    1986-01-01

    After a brief recall on the French regulation concerning pressure vessels, the authors describe the experience and the devices used by Framatome for closing, repairing, sleeving and shot peening for steam generators tubes bundles [fr

  11. The Rubens Tube: A Flaming Good Way to Teach Waves

    Science.gov (United States)

    Sandoval, Christopher

    2013-01-01

    The Ruben Flame Tube is named after H. Ruben, who published the demonstration experiment in "Annalen der Physik" in 1905. This article presents one of the many demonstrations the author uses to engage, motivate, and challenge his students.

  12. Evaluating the Effect of Dental Filling Material and Filling Depth on the Strength and Deformation of Filled Teeth

    Directory of Open Access Journals (Sweden)

    Seifollah Gholampour

    2016-10-01

    Full Text Available ackground and aim: It is important to evaluate the effect of the type of filling material on deformation and strength of tooth after filling and also the effect of filling depth on quality of restoration of a decayed tooth. Material and Methods: The Orthopantomogram (OPG of the first and second molars of a 28-year-old man was made and the teeth were 3D modeled. The stress-deformation analysis was then performed on the models in the three states of normal tooth, tooth filled with amalgam and tooth filled with composite using finite element method under a distributed load of 400N equivalent to chewing force. Two values (1/2 and 1/3 of the tooth height were considered for filling depth in the analyses. Results: The results showed that the normal first molar was exposed to a 7.2% greater risk of dental injuries compared to the normal second molar and also a greater stress is created in it when it is filled with composite. The first molar filled with a composite material is 13.7% weaker than the normal tooth while it is almost as strong as a normal tooth when it is filled with amalgam. The effect of the type of filling material on the strength and deformation of the second molar was trivial. Conclusion: Amalgam is a more proper dental filling material for the first molar although a 16.7% change in drilling depth is needed for tooth preparation. Dental filling material and filling depth have a small effect on the strength and deformation of filled second molars.

  13. Axial Compression Properties Nonlinear Analysis on Square Double Skin Steel Stub Short Columns Filled with Recycled Concrete

    Directory of Open Access Journals (Sweden)

    Song Bing

    2016-01-01

    Full Text Available Taking the mixing amount of diatomite calcined and vitrified micro bubbles(VMB as the main changing parameters, experiment studies the properties of the vitrified micro bubbles recycled concrete blocks; then this paper adopts the finite element software ANSYS to analyze the square double skin steel stub short columns filled with recycled concrete under axial compression. According to the vertical stress distribution, strain and bearing capacity of the steel tube and core concrete, we make a contrastive axial compression properties analysis on the different hollow ratio χ(0,0.35and the VMB content(0%,100%,130% of square double skin steel stub short columns filled with recycled concrete. The result shows that: Compressive strength of VMB recycled concrete increases with the increase of diatomite calcined content, when mixing amount of diatomite calcined is 3%,the compressive strength of 130% VMB content test specimen can reach 32.45 MPa;Because of the inner circular steel tube is setted which strengthening component buckling capacity and improving the ductility of the component, stress distribution of hollow components is more balance than solid components, and their axial displacements decrease by 5.6% compared with the solid components when they reach ultimate bearing capacity; When the hollow ratio is same, ultimate bearing capacity of 130% VMB content test specimen compared with the content is 0% only reduces by about 3.5%; When the VMB content is same, ultimate bearing capacity of hollow components compared with solid components increases by about 2.5%, which reducing weight as well as improving the anti-seismic performance.

  14. Neutron image intensifier tubes

    International Nuclear Information System (INIS)

    Verat, M.; Rougeot, H.; Driard, B.

    1983-01-01

    The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter: in the direct method, the film is exposed during the time that the object is irradiated with neutrons; in the transfer method, the film is exposed after the irradiation of the object with neutrons. In industrial non-destructive testing, when many identical objects have to be checked, these techniques have several disadvantages. Non-destructive testing systems without these disadvantages can be constructed around neutron-image intensifier tubes. A description and the operating characteristics of neutron-image intensifier tubes are given. (Auth.)

  15. Neural tube defects

    Directory of Open Access Journals (Sweden)

    M.E. Marshall

    1981-09-01

    Full Text Available Neural tube defects refer to any defect in the morphogenesis of the neural tube, the most common types being spina bifida and anencephaly. Spina bifida has been recognised in skeletons found in north-eastern Morocco and estimated to have an age of almost 12 000 years. It was also known to the ancient Greek and Arabian physicians who thought that the bony defect was due to the tumour. The term spina bifida was first used by Professor Nicolai Tulp of Amsterdam in 1652. Many other terms have been used to describe this defect, but spina bifida remains the most useful general term, as it describes the separation of the vertebral elements in the midline.

  16. Germ tube-specific antigens of Candida albicans cell walls

    International Nuclear Information System (INIS)

    Sundstrom, P.R.

    1986-01-01

    Studies were performed to characterize the surface differences between blastospores and germ tubes of the pathogenic, dimorphic yeast, Candida albicans, and to identify components of yeast cells responsible for these differences. Investigation of surfaces differences of the two growth forms was facilitated by the production of rabbit antiserum prepared against Formalin-treated yeast possessing germ tubes. To prepare antiserum specific for germ tubes, this serum was adsorbed with stationary phase blastospores. Whereas the unadsorbed antiserum reacted with both blastospore and germ tube forms by immunofluorescence and Enzyme-Linked Immunosorbent Assay, the adsorbed antiserum did not react with blastospores but detected germ tube-specific antigens in hyphal forms. The differences between blastospores and germ tubes of Candida albicans, were further studied by comparing enzymatic digests of cell walls of both growth forms in radiolabeled organisms. Organisms were labeled either on the surface with 125 I, or metabolically with [ 35 S] methionine or [ 3 H] mannose. Three-surface-located components (as shown by antibody adsorption and elution experiments) were precipitated from Zymolase digests. All three components were mannoproteins as shown by their ability to bind Concanavalin A, and to be labeled in protein labeling procedures, and two of these (200,000 and 155,000 molecular weight) were germ tube specific, as shown by their ability to be precipitated by germ tube-specific antiserum. Monoclonal antibodies were prepared to C. albicans, using blastospores bearing germ tubes as immunogen

  17. Paramecium swimming in capillary tube

    Science.gov (United States)

    Jana, Saikat; Um, Soong Ho; Jung, Sunghwan

    2012-04-01

    Swimming organisms in their natural habitat need to navigate through a wide range of geometries and chemical environments. Interaction with boundaries in such situations is ubiquitous and can significantly modify the swimming characteristics of the organism when compared to ideal laboratory conditions. We study the different patterns of ciliary locomotion in glass capillaries of varying diameter and characterize the effect of the solid boundaries on the velocities of the organism. Experimental observations show that Paramecium executes helical trajectories that slowly transition to straight lines as the diameter of the capillary tubes decreases. We predict the swimming velocity in capillaries by modeling the system as a confined cylinder propagating longitudinal metachronal waves that create a finite pressure gradient. Comparing with experiments, we find that such pressure gradient considerations are necessary for modeling finite sized ciliary organisms in restrictive geometries.

  18. Active Monitoring of Hydraulic Fractures Using Slow Waves in the Fracture and Tube Waves in the Borehole

    Science.gov (United States)

    Maximov, G. A.; Derov, A.; Lesonen, D.; Kashtan, B.; Lazarkov, M.

    2010-12-01

    amplitudes of these secondary tube waves produced by slow eigenmode traveling along fracture from its tips, when eigenmode is generated by external seismic wave. Using averaging procedure we present the non-uniform pseudo-differential wave equation for slow eigenmode in the fluid-filled fracture. This equation is derived in space-time representation assuming long-wavelength approximation. Derived wave equation takes into account strong dispersion of slow wave and contribution of incident external seismic field. We state and solve the boundary problem describing slow mode excited at the fracture tips. We showed that the developed analytical approach correctly computes amplitude and waveforms of the slow fracture mode excited by an external seismic wavefield from an offset source. We validated new approach by comparison with the finite-difference modeling and estimated magnitude of the expected secondary tube waves for realistic fracture-well configurations. Numerical calculations show that amplitudes of the secondary tube wave can reach the same order as the primary tube wave amplitudes and hence be detectable in a field experiments and used for active monitoring of fracture size.

  19. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  20. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  1. Contour Erasure and Filling-in: New Observations

    Directory of Open Access Journals (Sweden)

    Stuart Anstis

    2014-04-01

    Full Text Available Contour erasure is a newly established form of flicker adaptation that diminishes the saliency of object edges leading to their complete disappearance (Anstis, S. 2013. Journal of Vision, 13(2:25, 1–14. If these “disappeared” objects are then viewed on textured backgrounds, the observers experience filling-in, the illusory sense of background completion in the absence of physical input. In a series of observations, we demonstrate that contour erasure can greatly speed up the filling-in (or fading of brightness. Based on these observations, we suggest that contour adaptation happens early in the magnocellular pathways.

  2. Plasma-filled diode based on the coaxial gun

    Science.gov (United States)

    Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N.

    2012-10-01

    The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.

  3. Experimental and numerical studies of choked flow through adiabatic and diabatic capillary tubes

    International Nuclear Information System (INIS)

    Deodhar, Subodh D.; Kothadia, Hardik B.; Iyer, K.N.; Prabhu, S.V.

    2015-01-01

    Capillary tubes are extensively used in several cooling applications like refrigeration, electronic cooling etc. Local pressure variation in adiabatic straight capillary tube (mini channel) is studied experimentally and numerically with R134a as the working fluid. Experiments are performed on two straight capillary tubes. It is found that the diameter is the most sensitive design parameter of the capillary tube. Experiments are performed on five helically coiled capillary tubes to quantify the effect of pitch and curvature of helically coiled capillary tube on the pressure drop. Non dimensionalized factor to account coiling of capillary tube is derived to calculate mass flow rate in helically coiled capillary tubes. Flow visualization in adiabatic capillary tube confirms the bubbly nature of two phase flow. Numerical and experimental investigations in diabatic capillary tube suggest that the use of positive displacement pump and choking at the exit of the channel ensures flow stability. - Highlights: • Model is developed to design capillary tube in adiabatic and diabatic condition. • Effect of coil curvature on pressure drop is studied experimentally. • Correlation is developed to predict mass flow rate in helical capillary tubes. • Flow visualization is carried out to check the type of two phase flow. • Effect of choked flow on diabatic capillary tubes is studied experimentally.

  4. Unsteady two dimensional multiphysical simulation on the radiating calandria tube under the subcooling boundary condition

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Se Myong [Kunsan National Univ., Kunsan (Korea, Republic of); Kim, Hyoung Tae [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    Inside the Calandria tubes in the moderator system of a heavy water reactor, there are pressure tubes undergoing high pressure and temperature. If the cooling water dries out due to the local film boiling at the outer tube boundary, the excessive heat flux can deform the pressure tube to even contact with outer Calandria tube. To limit the subcooling for the avoidance of dryout condition in a CANDU reactor, a suitable experiment should be proposed such as Ref.. In this study, we simulated this experiment in 2 D with COMSOL Multi physics.

  5. Tuning gain and bandwidth of traveling wave tubes using metamaterial beam-wave interaction structures

    International Nuclear Information System (INIS)

    Lipton, Robert; Polizzi, Anthony

    2014-01-01

    We employ metamaterial beam-wave interaction structures for tuning the gain and bandwidth of short traveling wave tubes. The interaction structures are made from metal rings of uniform cross section, which are periodically deployed along the length of the traveling wave tube. The aspect ratio of the ring cross sections is adjusted to control both gain and bandwidth. The frequency of operation is controlled by the filling fraction of the ring cross section with respect to the size of the period cell.

  6. Operation feedback of hydrogen filling station

    International Nuclear Information System (INIS)

    Pregassame, S.; Barral, K.; Allidieres, L.; Charbonneau, T.; Lacombe, Y.

    2004-01-01

    One of the technical challenges of hydrogen technology is the development of hydrogen infrastructures which satisfy either safety requirements and reliability of filling processes. AIR LIQUIDE realized an hydrogen filling station in Sassenage (France) operational since September 2003. This station is able to fill 3 buses a day up to 350bar by equilibrium with high pressure buffers. In parallel with commercial stations, the group wanted to create a testing ground in real conditions running with several objectives: validate on a full scale bench a simulation tool able to predict the temperature of both gas and cylinder's materials during filling processes; define the best filling procedures in order to reach mass, temperature and filling time targets; analyse the temperature distribution and evolution inside the cylinder; get a general knowledge about hydrogen stations from safety and reliability point of view; operate the first full scale refuelling station in France. The station is also up-graded for 700bar filling from either a liquid hydrogen source or a gas booster, with cold filling possibility. This paper presents the results concerning 350bar filling : thermal effects, optimal filling procedures and influence of parameters such as climatic conditions are discussed. (author)

  7. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... position was measured on the polymer μ-parts to evaluate filling behavior of the polymer melt flowing through μ-features. Experimental results obtained under different processing conditions were evaluated to correlate the process parameter levels influence on the selected responses. Results showed...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  8. Dedicated composite fillings − inlays

    Directory of Open Access Journals (Sweden)

    Šaulić Slobodan

    2003-01-01

    Full Text Available Background. The aim of the study was to evaluate the quality and persistance of esthetics of dedicated inlay by clinical methods. Methods. The paper reviews the clinical significance and technique of preparing particular composite inlays before and after the construction of the metallic framework partial denture. On the basis of indications the total of 30 inlays were placed into cavities under relatively dry working conditions. Six, twelve eighteen and twenty-four months after the placement of filling, control check-up was carried out by Ryge criteria. Results. After two years marginal discoloration as well as the change of the colour occured in 3.3% of inlays. There was neither detectable secondary caries, nor the symtoms of pulpal damage. The requirements to be fulfilled concerning the composite materials in order that they can be implemented for this purpose, were also discussed. Conclusion. From the clinical point of view, purpouse inlays from Herculite XRV lab C8B in combination with Opti Bond System and composite cement Porcelite Dual Cure showed high functional and esthetic values in the observational period of two years.

  9. Defect-induced mix experiment for NIF

    Directory of Open Access Journals (Sweden)

    Schmitt M.J.

    2013-11-01

    Full Text Available The Defect Induced Mix Experiment (DIME-II will measure the implosion and mix characteristics of CH capsules filled with 5 atmospheres of DT by incorporating mid-Z dopant layers of Ge and Ga. This polar direct drive (PDD experiment also will demonstrate the filling of a CH capsule at target chamber center using a fill tube. Diagnostics for these experiments include areal x-ray backlighting to obtain early time images of the implosion trajectory and a multiple-monochromatic imager (MMI to collect spectrally-resolved images of the capsule dopant line emission near bangtime. The inclusion of two (or more thin dopant layers at separate depths within the capsule shell facilitates spatial correlation of mix between the layers and the hot gas core on a single shot. The dopant layers are typically 2 μm thick and contain dopant concentrations of 1.5%. Three dimensional Hydra simulations have been performed to assess the effects of PDD asymmetry on capsule performance.

  10. Buckling of ZnS-filled single-walled carbon nanotubes – The influence of aspect ratio

    KAUST Repository

    Monteiro, André O.

    2014-08-16

    The mechanical response of single-walled carbon nanotubes (SWCNT) filled with crystalline zinc sulphide (ZnS) nanowires under uniaxial compression is studied using classical molecular dynamics. These simulations were used to analyse the behaviour of SWCNT, with and without ZnS filling, in terms of critical force and critical strain. Force versus strain curves have been computed for hollow and filled systems, the latter clearly showing an improvement of the mechanical behaviour caused by the ZnS nanowire. The same simulations were repeated for a large range of dimensions in order to evaluate the influence of the aspect ratio on the mechanical response of the tubes.

  11. Stability of a laminar flame front propagating within a tube

    Energy Technology Data Exchange (ETDEWEB)

    Salamandra, G.D.; Maiorov, N.I.

    1983-01-01

    This study examines the deformation of a flame propagating in a semi-closed horizontal tube under the action of perturbations artifically created on the flame surface by brief action of a transverse electrical field on the combustion zone. The experiments were performed in a tube with square section 36 x 36 mm, with electrodes on the upper and lower walls for application of an electric field to the combustion zone. A high negative voltage was applied to the upper electrode for a regulated time interval, with the lower electrode grounded. Concludes that development of artificially created perturbations on the surface of a flame propagating in a semiclosed horizontal tube has been observed; the magnitude of the perturbations increases by an exponential law; fine scale perturbations on the flame surface are suppressed by coarse scale perturbations; and the stable curved form of the flame front in the tube is ensured by the stabilizing action of the tube walls.

  12. Vortex Tube Modeling Using the System Identification Method

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jaeyoung; Jeong, Jiwoong; Yu, Sangseok [Chungnam Nat’l Univ., Daejeon (Korea, Republic of); Im, Seokyeon [Tongmyong Univ., Busan (Korea, Republic of)

    2017-05-15

    In this study, vortex tube system model is developed to predict the temperature of the hot and the cold sides. The vortex tube model is developed based on the system identification method, and the model utilized in this work to design the vortex tube is ARX type (Auto-Regressive with eXtra inputs). The derived polynomial model is validated against experimental data to verify the overall model accuracy. It is also shown that the derived model passes the stability test. It is confirmed that the derived model closely mimics the physical behavior of the vortex tube from both the static and dynamic numerical experiments by changing the angles of the low-temperature side throttle valve, clearly showing temperature separation. These results imply that the system identification based modeling can be a promising approach for the prediction of complex physical systems, including the vortex tube.

  13. Shock Tube as an Impulsive Application Device

    Directory of Open Access Journals (Sweden)

    Soumya Ranjan Nanda

    2017-01-01

    Full Text Available Current investigations solely focus on application of an impulse facility in diverse area of high-speed aerodynamics and structural mechanics. Shock tube, the fundamental impulse facility, is specially designed and calibrated for present objectives. Force measurement experiments are performed on a hemispherical test model integrated with the stress wave force balance. Similar test model is considered for heat transfer measurements using coaxial thermocouple. Force and heat transfer experiments demonstrated that the strain gauge and thermocouple have lag time of 11.5 and 9 microseconds, respectively. Response time of these sensors in measuring the peak load is also measured successfully using shock tube facility. As an outcome, these sensors are found to be suitable for impulse testing. Lastly, the response of aluminum plates subjected to impulsive loading is analyzed by measuring the in-plane strain produced during deformation. Thus, possibility of forming tests in shock is also confirmed.

  14. PROSPECTS OF ESTABLISHING EARTHQUAKE RESISTANT BUILDINGS FROM TUBE CONCRETE CONSTRUCTIONS

    Directory of Open Access Journals (Sweden)

    Abdujafar I. Akaev

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the research is to find optimal design solutions for the erection of buildings that will ensure their reliability and durability, compliance with environmental requirements, fire resistance and earthquake resistance. In this regard, the task is to determine the advantages and prospects of erecting earthquake resistant buildings from tube concrete constructions, since they are distinct in constructive, technological and economic efficiency when are used as vertical load-bearing struts of high-rise buildings. Method The technique for calculating the strength of normal sections of eccentrically-compressed tube concrete elements uses a nonlinear deformation model, taking into account the joint operation of the steel shell and the concrete core under the conditions of triaxial compression. Results In the article the review of the newest world experience of using tube concrete as vertical load-bearing structures for public facilities from the standpoint of earthquake resistant construction is given. The international practices of public facility construction ranging in height from 100 to 600 m with the use of tube concrete technology, including regions with dangerous natural and man-made conditions, have been studied. The structural, operational and technological advantages and disadvantages of tube concrete technology are analysed. Methods for calculating the strength of concrete tube elements in the case of central compression are considered: according to the so-called deformation theory, the state of total destruction of both concrete and tube fluidity attained at maximum pressure are indicated by the beginning of "tube flow on the longitudinal axis". The advantages and disadvantages of both methods are shown. Factors constraining the introduction and wider application of tube concrete constructions in Russia are considered. Conclusion While the advantages of concrete tube constructions in their extensive

  15. Digital imaging with a pressurized Xenon filled MWPC working at a high data rate

    International Nuclear Information System (INIS)

    Bellazzini, R.; Brez, A.; Del Guerra, A.; Massai, M.M.; Torquati, M.R.; Franchi, M.; Perri, G.

    1984-01-01

    A multiwire proportional chamber based detection system for medical imaging is presented. The system consists of a pressurized xenon filled MWPC and of a monochromatic fluorescent, X-ray source using a conventional diagnostic tube with various target filter combinations. The main performance of the system are: 10% efficiency, 30% energy resolution 500 micro m spatial resolution, +-5 uniformity. The preliminary results of the application of this system to bone densitometry are presented

  16. Explosively Bonded Gun Tube Liner Development

    Science.gov (United States)

    2015-04-01

    that waterjet cutting will be the best approach to rifling the tube due to cost considerations. This technology can be rated at an MRL of 3. If the...WA), which had experience cutting grooves in both metallic and ceramic materials, was awarded a Phase 1 SBIR to investigate the use of waterjet ... cutting to rifle the liner. Waterjet uses a stream of abrasive particles entrained in water to cut through many types of materials. The primary question

  17. Mekong Floods Fill Tonle Sap

    Science.gov (United States)

    2002-01-01

    The monsoon season in Southeast Asia brings recurring, often devastating floods to countries in the region, but these floods also play a necessary role in the region's water cycle. These MODIS images centered on Cambodia reveal extensive flooding of the Mekong River, which comes in from Laos in the north, to the right of center in the images, and flows south through Cambodia and southeast through Vietnam to empty into the South China Sea. The true-color image shows the brownish, sediment-laden floodwaters filling the Mekong Delta in southern Cambodia and Vietnam on September 15, 2001. The false color image above has been enhanced to bring out the contrast between the floodwaters and the lands, with sediment-carrying floodwaters in purple. Sediment can be seen flowing into the South China Sea as well. This year's floods have affected over a million people, and 100 people have been killed in Vietnam alone. The monsoon floods bring not only devastation, but renewal. The large body of water just left of center in Cambodia is the Tonle Sap. This shallow lake plays a changing role in the regional water cycle. During the dry season, the stream-fed Tonle Sap drains via the Tonle Sab River into the Mekong River. During the wet season (June-November), flooding of the Mekong reverses the course of the Tonle Sab, roughly tripling the lake's size from about 3000 km2 to about 10,000. When the dry season returns, the lake once again begins to drain into the Mekong Delta, where it provides a flow of fresh water that balances the intrusion of salty seawater into the delta's agricultural lands. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  18. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  19. YouTube and Video Quizzes

    Directory of Open Access Journals (Sweden)

    Kevin YEE

    2010-04-01

    Full Text Available The Internet sensation YouTube (http://www.youtube.com has become such a force online that it was estimated in 2006 to account for a full tenth of the bandwidth by the entire Internet in the United States (WebProNews, 2007, and to use as much bandwidth in 2007 as the entire Internet had done in 2000 (Carter, 2008. Like many technological tools created with entertainment or profit in mind, YouTube can now be easily and usefully adopted by instructors for educational purposes, and indeed many professors use YouTube in their classroom teaching already (Brooks, 2000. This is especially true for passive uses of YouTube; watching videos that are already online and using them in the classroom experience to support a concept and provide another mechanism for students to connect with the topics. It is fruitful to consider Bloom's Taxonomy of Educational Objectives (Bloom & Krathwohl, 1956 when employing video or any media in the classroom to maximize the intentionality of teaching and learning. The use of video for demonstration or modeling corresponds well to Blooms levels of Knowledge, Comprehension, and Application; while case studies offer a chance to demonstrate Analysis and Synthesis, and perhaps even Evaluation, when comparing a video to information from a text book or other content.

  20. Hydrogen tube vehicle for supersonic transport: 2. Speed and energy

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Arnold R. [Vehicle Projects Inc and Supersonic Tubevehicle LLC, 200 Violet St, Suite 100, Golden, CO 80401 (United States)

    2010-06-15

    The central concept of a new idea in high-speed transport is that operation of a vehicle in a hydrogen atmosphere, because of the low density of hydrogen, would increase sonic speed by a factor of 3.8 and decrease drag by 15 relative to air. A hydrogen atmosphere requires that the vehicle operate within a hydrogen-filled tube or pipeline, which serves as a phase separator. The supersonic tube vehicle (STV) can be supersonic with respect to air outside the tube while remaining subsonic inside. It breathes hydrogen fuel for its propulsion fuel cells from the tube itself. This paper, second in a series on the scientific foundations of the supersonic tube vehicle, tests the hypothesis that the STV will be simultaneously fast and energy efficient by comparing its predicted speed and energy consumption with that of four long-haul passenger transport modes: road, rail, maglev, and air. The study establishes the speed ranking STV >> airplane > maglev > train > coach (intercity bus) and the normalized energy consumption ranking Airplane >> coach > maglev > train > STV. Consistent with the hypothesis, the concept vehicle is both the fastest and lowest energy consuming mode. In theory, the vehicle can cruise at Mach 2.8 while consuming less than half the energy per passenger of a Boeing 747 at a cruise speed of Mach 0.81. (author)

  1. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  2. Failure analysis of boiler tube

    International Nuclear Information System (INIS)

    Mehmood, K.; Siddiqui, A.R.

    2007-01-01

    Boiler tubes are energy conversion components where heat energy is used to convert water into high pressure superheated steam, which is then delivered to a turbine for electric power generation in thermal power plants or to run plant and machineries in a process or manufacturing industry. It was reported that one of the tubes of a fire-tube boiler used in a local industry had leakage after the formation of pits at the external surface of the tube. The inner side of the fire tube was working with hot flue gasses with a pressure of 10 Kg/cm/sup 2/ and temperature 225 degree C. The outside of the tube was surrounded by feed water. The purpose of this study was to determine the cause of pits developed at the external surface of the failed boiler tube sample. In the present work boiler tube samples of steel grade ASTM AI61/ASTM A192 were analyzed using metallographic analysis, chemical analysis, and mechanical testing. It was concluded that the appearance of defects on the boiler tube sample indicates cavitation type corrosion failure. Cavitation damage superficially resembled pitting, but surface appeared considerably rougher and had many closely spaced pits. (author)

  3. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  4. Microleakage of Cavit temporary filling material in endodontic access cavities in monkey teeth.

    Science.gov (United States)

    Lamers, A C; Simon, M; van Mullem, P J

    1980-06-01

    Sealing properties of Cavit-W temporary filling material were tested in vivo in the control group of a usage experiment in which root canal disinfectants were studied. Histologic examination (Brown and Brenn staining) of the root canals showed a statistical significance in the occurrence of microorganisms with increase in time. Microleakage past the filling material was considered to be responsible.

  5. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  6. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  7. Comparison of the performance of concrete-filled steel tubular and hollow steel diagrid buildings

    Science.gov (United States)

    Peter, Minu Ann; S, Sajith A.; Nagarajan, Praveen

    2018-03-01

    In the recent construction scenario, diagrid structures are becoming a popular high-rise building structural system. Diagrid structures consist of diagonals in the perimeter and an interior core. The corner and interior vertical columns are not required due to the structural efficiency of diagrid structural systems. Steel and concrete are commonly used material for diagrid. An alternate material for diagrid is concrete-filled steel tube (CFST). CFST incorporates the advantages of both steel and concrete. In CFST, the inward buckling of the steel tube is effectively prevented by the filled concrete. The compressive strength of concrete increases due to the tri-axial state of stress in concrete induced by the steel tube. The longitudinal as well as lateral reinforcement to the concrete core is also provided by the steel tube. This paper compares the performance of CFST and steel diagrid buildings using linear static analysis. For this purpose, a 12 storey and 36 storey building are analysed using finite element method and CFST diagrid building is found to perform better.

  8. Quick Detection of Contaminants Leaching from Polypropylene Centrifuge Tube with Surface Enhanced Raman Spectroscopy and Ultra Violet Absorption Spectroscopy

    OpenAIRE

    Xu, Zhida; Liu, Logan

    2014-01-01

    Anomalous surface enhanced Raman scattering (SERS) peaks are identified for liquid sample stored in polypropylene centrifuge tubes (PP tube) for months. We observed the unexpected Raman peaks during experiments for Thiamine Hydrochloride aqueous solution stored in PP tube for two months. In order to identify the contaminants we have performed SERS experiments for de-ionized water (DI water) stored in polypropylene centrifuge tube for two months and compared them with fresh DI water sample. We...

  9. Thermodynamic and fluid mechanic analysis of rapid pressurization in a dead-end tube

    Science.gov (United States)

    Leslie, Ian H.

    1989-01-01

    Three models have been applied to very rapid compression of oxygen in a dead-ended tube. Pressures as high as 41 MPa (6000 psi) leading to peak temperatures of 1400 K are predicted. These temperatures are well in excess of the autoignition temperature (750 K) of teflon, a frequently used material for lining hoses employed in oxygen service. These findings are in accord with experiments that have resulted in ignition and combustion of the teflon, leading to the combustion of the stainless steel braiding and catastrophic failure. The system analyzed was representative of a capped off-high-pressure oxygen line, which could be part of a larger system. Pressurization of the larger system would lead to compression in the dead-end line, and possible ignition of the teflon liner. The model consists of a large plenum containing oxygen at the desired pressure (500 to 6000 psi). The plenum is connected via a fast acting valve to a stainless steel tube 2 cm inside diameter. Opening times are on the order of 15 ms. Downstream of the valve is an orifice sized to increase filling times to around 100 ms. The total length from the valve to the dead-end is 150 cm. The distance from the valve to the orifice is 95 cm. The models describe the fluid mechanics and thermodynamics of the flow, and do not include any combustion phenomena. A purely thermodynamic model assumes filling to be complete upstream of the orifice before any gas passes through the orifice. This simplification is reasonable based on experiment and computer modeling. Results show that peak temperatures as high as 4800 K can result from recompression of the gas after expanding through the orifice. An approximate transient model without an orifice was developed assuming an isentropic compression process. An analytical solution was obtained. Results indicated that fill times can be considerably shorter than valve opening times. The third model was a finite difference, 1-D transient compressible flow model. Results from

  10. The pulse tube engine: A numerical and experimental approach on its design, performance, and operating conditions

    International Nuclear Information System (INIS)

    Moldenhauer, Stefan; Stark, Tilman; Holtmann, Christoph; Thess, André

    2013-01-01

    The pulse tube engine is a simple heat engine based on the pulse tube process. Due to its simplicity it has a high potential to be applicable in waste heat usage and energy harvesting purposes. In this work, mathematical and experimental design tools are developed to study a pressurized laboratory scale pulse tube engine. The mathematical model is based on the transient numerical solution of the governing differential equations for mass, momentum and energy. The Modelica environment of SimulationX is used to solve the equations numerically and the model is employed to design the experimental test engine with helium as working fluid. The transient behavior of the pulse tube engine's underlying thermodynamic properties is studied numerically and experimentally under different design parameters as well as for different heat input temperatures, filling pressures and operating frequencies. The measured engine characteristics are compared with the calculated predictions. Internal and external power losses are quantified. Design studies for a further development of the pulse tube engine are performed experimentally. The developed numerical tool provides a rational framework for up-scaling the current laboratory model to industrial scale. - Highlights: • We developed a mathematical model and an experimental test engine to study the pulse tube engine. • The experimental test engine is able to operate with pressurized helium of up to 12 bar filling pressure. • We characterized and compared the engine's behavior under different design features and operating conditions. • Design studies for a further development of the pulse tube engine are performed experimentally

  11. Correlation Between Endotracheal Tube Cuff Pressure and Tracheal Wall Pressure Using Air and Saline Filled Cuffs

    Science.gov (United States)

    2017-01-31

    sell any patented invention that may relate to them. Qualified requestors may obtain copies of this report from the Defense Technical Information...been the assumption that the pressure measured at the pilot balloon is equal to the pressure exerted on the TW. We evaluated ETTs at sea level and...Pressure Profile Systems, Los Angeles, CA) and the ETT pilot balloon via a data logger (Sparx Engineering, Manvel, TX). Figure 1

  12. Numerical Study on the Behaviour of Reduced Beam Section Presence in Rectangular Concrete Filled Tubes Connection

    Science.gov (United States)

    Amalia, A. R.; Suswanto, B.; Kristijanto, H.; Irawan, D.

    2018-01-01

    This paper discusses about the behaviour of two types of RCFT column connections with steel beams due to cyclic loads using software based on finite element method ABAQUS 6.14. This comparison involves modelling RCFT connections with rigid connection that do not allow any deformation and rotation in the joint. There are two types of model to be compared: BB and BRBS which include RCFT connections to ordinary beam without RBS (BB) and to Reduce Beam Section Beam (BRBS). The models behaviour can be discussed in this study are stress value, von misses stress pattern and rotational degree of each model. From the von misses stress pattern value, it found that the highest regions of stress occurs in vicinity of beam flange near column face for connection without RBS (BB). For earthquake resistant building, that behaviour needs to be avoided because sudden collapse often happen in that joint connection. Moreover, the connection with the presence of RBS (BRBS), the highest regions of stress occurs in reduced beam section of the beam, it means that the failure might be happen as proposed plan. The ultimate force that can be restrained by BB model (402 kN) is higher than BRBS model (257,18 kN) because of reducing of flange area. BRBS model has higher rotation angle (0,057 rad) than BB model (0,045 rad). The analysis results also observed that cyclic performances of the moment connection with RBS (BRBS) were more ductile than the connection with ordinary beam (BB).

  13. How to Fill a Narrow 27 km Long Tube with a Huge Number of Accelerator Components?

    CERN Document Server

    Muttoni, Yvon; Valbuena, Roger

    2005-01-01

    As in large scale industrial projects, research projects, such as giant and complex particle accelerators, require intensive spatial integration studies using 3D CAD models, from the design to the installation phases. The future management of the LHC machine configuration during its operation will rely on the quality of the information, produced during these studies.This paper presents the powerful data-processing tools used in the project to ensure the spatial integration of several thousand different components in the limited space available.It describes how the documentation and information generated have been made available to a great number of users through a dedicated Web site and how installation nonconformities were handled.

  14. How to fill a narrow 27 KM long tube with a huge number of accelerator components?

    CERN Document Server

    Muttoni, Y; Valbuena, R

    2005-01-01

    As in large scale industrial projects, research projects, such as giant and complex particle accelerators, require intensive spatial integration studies using 3D CAD models, from the design to the installation phases. The future management of the LHC machine configuration during its operation will rely on the quality of the information, produced during these studies. This paper presents the powerful data-processing tools used in the project to ensure the spatial integration of several thousand different components in the limited space available. It describes how the documentation and information generated have been made available to a great number of users through a dedicated Web site and how installation nonconformities were handled.

  15. Transfer coefficients for plate fin and elliptical tube heat exchangers

    International Nuclear Information System (INIS)

    Saboya, S.M.; Saboya, F.E.M.

    1981-01-01

    In order to determine transfer coefficients for plate fin and elliptical tube exchangers, mass transfer experiments have been performed using the naphthalene sublimation technique. By means of the heat-mass transfer analogy, the results can be converted to heat transfer results. The transfer coefficients were compared with those for circular tube exchangers and the comparison revealed no major differences. This is a positive outcome, since the use of elliptical tubes may reduce substantially the pressure drop, without affecting the transfer characteristics.(Author) [pt

  16. Equilibrium Conformations of Concentric-tube Continuum Robots.

    Science.gov (United States)

    Rucker, D Caleb; Webster, Robert J; Chirikjian, Gregory S; Cowan, Noah J

    2010-09-01

    Robots consisting of several concentric, preshaped, elastic tubes can work dexterously in narrow, constrained, and/or winding spaces, as are commonly found in minimally invasive surgery. Previous models of these "active cannulas" assume piecewise constant precurvature of component tubes and neglect torsion in curved sections of the device. In this paper we develop a new coordinate-free energy formulation that accounts for general preshaping of an arbitrary number of component tubes, and which explicitly includes both bending and torsion throughout the device. We show that previously reported models are special cases of our formulation, and then explore in detail the implications of torsional flexibility for the special case of two tubes. Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models; it reduces model prediction error by 82% over the calibrated bending-only model, and 17% over the calibrated transmissional torsion model in a set of experiments.

  17. 7 CFR 58.730 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.730 Section 58.730 Agriculture... Procedures § 58.730 Filling containers. Hot fluid cheese from the cookers may be held in hotwells or hoppers... shall effectively measure the desired amount of product into the pouch or container in a sanitary manner...

  18. Influence of template fill in graphoepitaxy DSA

    Science.gov (United States)

    Doise, Jan; Bekaert, Joost; Chan, Boon Teik; Hong, SungEun; Lin, Guanyang; Gronheid, Roel

    2016-03-01

    Directed self-assembly (DSA) of block copolymers (BCP) is considered a promising patterning approach for the 7 nm node and beyond. Specifically, a grapho-epitaxy process using a cylindrical phase BCP may offer an efficient solution for patterning randomly distributed contact holes with sub-resolution pitches, such as found in via and cut mask levels. In any grapho-epitaxy process, the pattern density impacts the template fill (local BCP thickness inside the template) and may cause defects due to respectively over- or underfilling of the template. In order to tackle this issue thoroughly, the parameters that determine template fill and the influence of template fill on the resulting pattern should be investigated. In this work, using three process flow variations (with different template surface energy), template fill is experimentally characterized as a function of pattern density and film thickness. The impact of these parameters on template fill is highly dependent on the process flow, and thus pre-pattern surface energy. Template fill has a considerable effect on the pattern transfer of the DSA contact holes into the underlying layer. Higher fill levels give rise to smaller contact holes and worse critical dimension uniformity. These results are important towards DSA-aware design and show that fill is a crucial parameter in grapho-epitaxy DSA.

  19. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  20. Nasogastric tube syndrome induced by an indwelling long intestinal tube.

    Science.gov (United States)

    Sano, Naoki; Yamamoto, Masayoshi; Nagai, Kentaro; Yamada, Keiichi; Ohkohchi, Nobuhiro

    2016-04-21

    The nasogastric tube (NGT) has become a frequently used device to alleviate gastrointestinal symptoms. Nasogastric tube syndrome (NTS) is an uncommon but potentially life-threatening complication of an indwelling NGT. NTS is characterized by acute upper airway obstruction due to bilateral vocal cord paralysis. We report a case of a 76-year-old man with NTS, induced by an indwelling long intestinal tube. He was admitted to our hospital for treatment of sigmoid colon cancer. He underwent sigmoidectomy to release a bowel obstruction, and had a long intestinal tube inserted to decompress the intestinal tract. He presented acute dyspnea following prolonged intestinal intubation, and bronchoscopy showed bilateral vocal cord paralysis. The NGT was removed immediately, and tracheotomy was performed. The patient was finally discharged in a fully recovered state. NTS be considered in patients complaining of acute upper airway obstruction, not only with a NGT inserted but also with a long intestinal tube.

  1. Piezoelectric Rotary Tube Motor

    Science.gov (United States)

    Fisher, Charles D.; Badescu, Mircea; Braun, David F.; Culhane, Robert

    2011-01-01

    A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

  2. Pressure tube reactor

    International Nuclear Information System (INIS)

    Matsumoto, Tomoyuki; Fujino, Michihira.

    1980-01-01

    Purpose: To equalize heavy water flow distribution by providing a nozzle for externally injecting heavy water from a vibration preventive plate to the upper portion to feed the heavy water in a pressure tube reactor and swallowing up heavy water in a calandria tank to supply the heavy water to the reactor core above the vibration preventive plate. Constitution: A moderator injection nozzle is mounted on the inner wall of a calandria tank. Heavy water is externally injected above the vibration preventive plate, and heavy water in the calandria tank is swallowed up to supply the heavy water to the core reactor above the vibration preventive plate. Therefore, the heavy water flow distribution can be equalized over the entire reactor core, and the distribution of neutron absorber dissolved in the heavy water is equalized. (Yoshihara, H.)

  3. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  4. The long pollen tube journey and in vitro pollen germination of Phalaenopsis orchids.

    Science.gov (United States)

    Chen, Jhun-Chen; Fang, Su-Chiung

    2016-06-01

    Pollen biology in P. aphrodite. Orchids have a distinct reproductive program. Pollination triggers ovule development and differentiation within flowers, and fertilization occurs days to months after pollination. It is unclear how pollen tubes travel through the developing ovaries during ovule development and when pollen tubes arrive at the mature embryo sac to achieve fertilization. Here, we report a robust staining protocol to image and record the timing of pollen germination, progressive growth of pollen tubes in ovaries, and arrival of pollen tubes at embryo sacs in Phalaenopsis aphrodite. The pollen germinated and pollen tubes entered the ovary 3 days after pollination. Pollen tubes continued to grow and filled the entire cavity of the ovary as the ovary elongated and ovules developed. Pollen tubes were found to enter the matured embryo sacs at approximately 60-65 days after pollination in an acropetal manner. Moreover, these temporal changes in developmental events such as growth of pollen tubes and fertilization were associated with expression of molecular markers. In addition, we developed an in vitro pollen germination protocol, which is valuable to enable studies on pollen tube guidance and tip growth regulation in Phalaenopsis orchids and possibly in other orchid species.

  5. Dynamic Behavior of Hybrid APM (Advanced Pore Morphology Foam and Aluminum Foam Filled Structures

    Directory of Open Access Journals (Sweden)

    Joerg Weise

    2012-06-01

    Full Text Available The aim of this work is to evaluate the effect of different densities of hybrid aluminum polymer foam on the frequency behavior of a foam filled steel structure with different ratios between steel and foam masses. The foam filled structure is composed of three steel tubes with a welded flange at both ends bolted together to form a portal grounded by its free ends. Structure, internal and ground constraints have been designed and manufactured in order to minimize nonlinear effects and to guarantee optimal constraint conditions. Mode shapes and frequencies were verified with finite elements models (FEM to be in the range of experimental modal analysis, considering the frequency measurement range limits for instrumented hammer and accelerometer. Selected modes have been identified with suitable modal parameters extraction techniques. Each structure has been tested before and after filling, in order to compute the percentage variation of modal parameters. Two different densities of hybrid aluminum polymer foam have been tested and compared with structures filled with aluminum foams produced using the powder compact melting technique. All the foam fillings were able to suppress high frequency membrane modes which results in a reduction of environmental noise and an increase in performance of the components. Low frequency modes show an increase in damping ratio only when small thickness steel frames are filled with either Hybrid APM or Alulight foam.

  6. Hydraulic design considerations for a multi-tube sodium economizer

    International Nuclear Information System (INIS)

    Hassberger, J.A.; McConnell, P.M.; Olson, W.H.

    1975-01-01

    Operating experience gained from tests shows that flow distribution effects can severely affect the thermal performance of high effectiveness, low pressure drop sodium heat exchangers. It has been shown that design efforts for such devices must include proper consideration of potential causes of flow maldistribution within the tube bundle. Furthermore, it has been demonstrated that fairly simple design features can be capable of eliminating detrimental flow fields in the tube bundle

  7. Optimization strategies of in-tube extraction (ITEX) methods

    OpenAIRE

    Laaks, Jens; Jochmann, Maik A.; Schilling, Beat; Schmidt, Torsten C.

    2015-01-01

    Microextraction techniques, especially dynamic techniques like in-tube extraction (ITEX), can require an extensive method optimization procedure. This work summarizes the experiences from several methods and gives recommendations for the setting of proper extraction conditions to minimize experimental effort. Therefore, the governing parameters of the extraction and injection stages are discussed. This includes the relative extraction efficiencies of 11 kinds of sorbent tubes, either commerci...

  8. Effects of plasma physics on capsule implosions in gas-filled hohlraums

    Energy Technology Data Exchange (ETDEWEB)

    Lindman, E.L.; Delamater, N.D.; Magelssen, G.R.; Hauer, A.

    1994-10-01

    Initial experiments on capsule implosions in gas-filled hohlraums have been carried out on the NOVA Laser at Lawrence Livermore National Laboratory. Observed capsule shapes from preliminary experiments are more oblate than predicted. Improvements in modeling required to calculate these experiments and additional experiments are being pursued.

  9. Essential Characteristics of Plasma Antennas Filled with He-Ar Penning Gases

    International Nuclear Information System (INIS)

    Sun Naifeng; Li Wenzhong; Wang Shiqing; Li Jian; Ci Jiaxiang

    2012-01-01

    Based on the essential theory of Penning gases, the discharge characteristics of He-Ar Penning gases in insulating tubes were analyzed qualitatively. The relation between the effective length of an antenna column filled with He-Ar Penning gases and the applied radio frequency (RF) power was investigated both theoretically and experimentally. The distribution of the plasma density along the antenna column in different conditions was studied. The receiving characteristics of local frequency modulated (FM) electromagnetic waves by the plasma antenna filled with He-Ar Penning gases were compared with those by an aluminum antenna with the same dimensions. Results show that it is feasible to take plasma antennas filled with He-Ar Penning gases as receiving antennas.

  10. [Creep of amalgam fillings under clasp rests].

    Science.gov (United States)

    Borchers, L; Jung, T; West, M

    1989-10-01

    A clinically realistic experiment was set up to obtain information on the amount of vertical settling of clasp rests in amalgam restorations under functional loading. Mesioocclusal cavities were prepared in 16 lower molar specimens cast in brass. The cavities were filled with amalgam and provided with a mesial rest seat. A constant load of 100 N was applied via a simplified (experimental) saddle to a cobalt-chromium E-clasp cast to the saddle. The duration of the load corresponded to 160 days of clinical function. The chronological course of vertical displacement was analyzed mathematically. According to this result the process can be divided into three components: settling immediately upon load initiation (mean value 96 microns, transition creep (mean value 25 microns) and creep ata constant rate (mean value 15 microns). The mean overall vertical displacement of the rests was 136 microns, the maximum value 287 microns. These findings suggest that vertical settling of a clasp rest into its seat in an amalgam restoration may eventually result in significant changes in occlusion and may almost completely exhaust gingival resilience.

  11. Paramecium swimming in a capillary tube

    Science.gov (United States)

    Jana, Saikat; Jung, Sunghwan

    2010-03-01

    Micro-organisms exhibit different strategies for swimming in complex environments. Many micro-swimmers such as paramecium congregate and tend to live near wall. We investigate how paramecium moves in a confined space as compared to its motion in an unbounded fluid. A new theoretical model based on Taylor's sheet is developed, to study such boundary effects. In experiments, paramecia are put inside capillary tubes and their swimming behavior is observed. The data obtained from experiments is used to test the validity of our theoretical model and understand how the cilia influence the locomotion of paramecia in confined geometries.

  12. Characterization of tube support alloys

    International Nuclear Information System (INIS)

    Vaia, A.R.

    1985-01-01

    The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions

  13. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  14. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia NEI Home Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  15. 27 CFR 40.352 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 40.352... OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Manufacture of Cigarette Papers and Tubes Taxes § 40.352 Cigarette tubes. Cigarette tubes...

  16. Filling the vacuum at LHCb

    CERN Multimedia

    Katarina Anthony

    2013-01-01

    Last month, the Vacuum, Surfaces and Coatings (VSC) group was tasked with an unusually delicate operation in the LHCb experiment cavern: removing the LHC beam pipe while keeping the sensitive Vertex Locator vacuum vessel (VELO) completely isolated from the action.   The VSC group seal off the VELO beam pipe with a flange. Image: Gloria Corti. LHCb’s VELO detector is one of the crown jewels of the experiment. With detector elements surrounded by a vacuum, it gets as close as 5 cm from the beam. Fantastic for physics, but difficult for all-important access. “Because of the sensitivity of the VELO detector and its proximity to the beam, the collaboration decided not to bake (see box) its portion of the beam pipe,” says Giulia Lanza (TE-VSC-LBV), the expert in charge of the beam vacuum operation. “Our group was therefore asked to remove the rest of the LHC beam pipe while keeping the VELO portion of the pipe completely isolated. This work...

  17. Clean Industrial Room for Drift Tube Assembling

    CERN Document Server

    Glonti, GL; Evtoukhovitch, P G; Kroa, G; Manz, A; Potrap, I N; Rihter, P; Stoletov, G D; Tskhadadze, E G; Chepurnov, V F; Chirkov, A V; Shelkov, G A

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has been confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volum (\\sim 190 m^3), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2 %). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer.

  18. Quenching behaviour of hot zircaloy tube

    International Nuclear Information System (INIS)

    Chinchole, A.S.; Kulkarni, P.P.; Nayak, A.K.; Vijayan, P.K.

    2015-01-01

    The quenching process plays a very important role in case of safety of nuclear reactors. During large break Loss of Coolant Accident in a nuclear reactor, the cooling water from the system is lost. Under this condition, cold water is injected from emergency core cooling system. Quenching behaviour of such heated rod bundle is really complex. It is well known that nanofluids have better heat removal capability and high heat transfer coefficient owing to enhanced thermal properties. Alumina nano-particles result in better cooling abilities compared with the traditionally used quenching media. In this paper, the authors have carried out experiments on quenching behaviour of hot zircaloy tube with demineralized water and nanofluids. It was observed that, the tube got quenched within few seconds even with the presence of decay heat and shows slightly reduced quenching time compared with DM water. (author)

  19. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  20. Compact water depth sensor with LPFG using the photoelastic effect and heat-shrinkable tube

    Science.gov (United States)

    Takama, Shinya; Kudomi, Takamasa; Ohashi, Masaharu; Miyoshi, Yuji

    2011-12-01

    We propose a compact water depth sensor with a long period fiber grating (LPFG) using a heat-shrinkable tube. The pressure property of the LPFG is investigated experimentally to confirm the feasibility of the water depth sensor. Moreover, the water depth in the 2m long water-filled pipe is successfully estimated by the proposed water sensors.