  1. REFLECTANCE PULSE OXIMETRY IN FETAL LAMBS

    NARCIS (Netherlands)

    DASSEL, AC; GRAAFF, R; AARNOUDSE, JG; ELSTRODT, JM; HEIDA, P; KOELINK, MH; DEMUL, FF; GREVE, J

    1992-01-01

    Transmission pulse oximetry is used for monitoring in many clinical settings. However, for fetal monitoring during labor and in situations with poor peripheral perfusion, transmission pulse oximetry cannot be used. Therefore, we developed a reflectance pulse oximeter, which uses the relative intensi

  2. Adjustable fetal phantom for pulse oximetry

    Science.gov (United States)

    Stubán, Norbert; Niwayama, Masatsugu

    2009-05-01

    As the measuring head of a fetal pulse oximeter must be attached to the head of the fetus inside the mother's uterus during labor, testing, and developing of fetal pulse oximeters in real environment have several difficulties. A fetal phantom could enable evaluation of pulse oximeters in a simulated environment without the restrictions and difficultness of medical experiments in the labor room. Based on anatomic data we developed an adjustable fetal head phantom with three different tissue layers and artificial arteries. The phantom consisted of two arteries with an inner diameter of 0.2 and 0.4 mm. An electronically controlled pump produced pulse waves in the arteries. With the phantom we investigated the sensitivity of a custom-designed wireless pulse oximeter at different pulsation intensity and artery diameters. The results showed that the oximeter was capable of identifying 4% and 2% changes in diameter between the diastolic and systolic point in arteries of over 0.2 and 0.4 mm inner diameter, respectively. As the structure of the phantom is based on reported anatomic values, the results predict that the investigated custom-designed wireless pulse oximeter has sufficient sensitivity to detect the pulse waves and to calculate the R rate on the fetal head.

  3. Evaluation of non-reassuring fetal heart rate patterns with fetal pulse oximetry combined with vibratory acoustic stimulation.

    Science.gov (United States)

    Salamalekis, E; Vitoratos, N; Loghis, C; Kassanos, D; Salloum, I; Batalias, L; Creatsas, G

    2003-02-01

    To determine the value of fetal pulse oximetry and vibratory acoustic stimulation in the presence of non-reassuring fetal heart rate patterns during labor. Prospective study in women monitored by cardiotocography and fetal pulse oximetry during labor. During a period of 18 months, 907 consecutive parturients in labor were monitored by cardiotocography. Out of these women, 63 were selected on the basis of a non-reassuring fetal heart rate tracing during the first stage of labor. In these cases, fetal pulse oximetry was applied. Vibratory acoustic stimulation was applied in fetuses without spontaneous reactivity in order to evaluate the fetal status. Our cases were classified into three groups, according to the lower fetal oxygen saturation levels, from the time of oximetry application until delivery. Group A consisted of 29 cases where fetal oxygen saturation levels were > or = 41%, group B (20 cases) with fetal oxygen saturation of 31-40% and group C (14 cases) with levels of fetal oxygen saturation levels. The mean umbilical artery pH levels were 7.29 +/- 0.051 in group A, 7.21 +/- 0.057 in group B and 7.04 +/- 0.05 in group C. Fetal pulse oximetry should be indicated not only in fetuses without any reactivity but also in those with induced reactivity, after the application of vibratory acoustic stimulation.

  4. Principle study on the signal connection at transabdominal fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2016-09-01

    Full Text Available Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling.

  5. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Møller, Ann Merete; Hovhannisyan, Karen

    2009-01-01

    Pulse oximetry is extensively used in the perioperative period and might improve patient outcomes by enabling an early diagnosis and, consequently, correction of perioperative events that might cause postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry...

  6. Pulse oximetry for perioperative monitoring

    DEFF Research Database (Denmark)

    Pedersen, Tom; Nicholson, Amanda; Hovhannisyan, Karen

    2014-01-01

    . Results indicated that hypoxaemia was reduced in the pulse oximetry group, both in the operating theatre and in the recovery room. During observation in the recovery room, the incidence of hypoxaemia in the pulse oximetry group was 1.5 to three times less. Postoperative cognitive function was independent...... postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry during anaesthesia and in the recovery room have been performed that describe perioperative hypoxaemic events, postoperative cardiopulmonary complications and cognitive dysfunction. OBJECTIVES: To study the use...... checked the reference lists of trials and review articles. The original search was performed in January 2005, and a previous update was performed in May 2009. SELECTION CRITERIA: We included all controlled trials that randomly assigned participants to pulse oximetry or no pulse oximetry during...

  7. Pulse oximetry in severe anaemia

    DEFF Research Database (Denmark)

    Ramsing, T; Rosenberg, J

    1992-01-01

    Measurement of arterial oxygen saturation by pulse oximetry was performed in two patients with acute and chronic anaemia (haemoglobin concentrations: 2.9 mmol/l (4.7 g/dl) and 1.9 mmol/l (3.0 g/dl), respectively) using a Radiometer OXI and a Nellcor N-200 pulse oximeter. The two oximeters read...... alternating different values in the two patients. In conclusion, pulse oximeters are able to give a value for oxygen saturation even at extreme anaemia, and when a high value is given, it possibly reflects arterial oxygen saturation. The value of pulse oximetry in severe anaemia is discussed....

  8. Reflectance pulse oximetry at the forehead of newborns : The influence of varying pressure on the probe

    NARCIS (Netherlands)

    Dassel, ACM; Graaff, R; Zijlstra, WG; Aarnoudse, JG

    1996-01-01

    Objective: Transmission pulse oximetry (TPO) is not a practical method of intrapartum fetal monitoring of arterial oxygen saturation. Reflectance pulse oximetry (RPO) requires a sensor applied to the skin of the fetal head and may be a useful technique. During labor, various degrees of pressure will

  9. Reflectance pulse oximetry at the forehead of newborns : The influence of varying pressure on the probe

    NARCIS (Netherlands)

    Dassel, ACM; Graaff, R; Zijlstra, WG; Aarnoudse, JG

    1996-01-01

    Objective: Transmission pulse oximetry (TPO) is not a practical method of intrapartum fetal monitoring of arterial oxygen saturation. Reflectance pulse oximetry (RPO) requires a sensor applied to the skin of the fetal head and may be a useful technique. During labor, various degrees of pressure will

  10. Nasal pulse oximetry overestimates oxygen saturation

    DEFF Research Database (Denmark)

    Rosenberg, J; Pedersen, M H

    1990-01-01

    Ten surgical patients were monitored with nasal and finger pulse oximetry (Nellcor N-200) for five study periods with alternating mouth and nasal breathing and switching of cables and sensors. Nasal pulse oximetry was found to overestimate arterial oxygen saturation by 4.7 (SD 1.4%) (bias...

  11. [Noninvasive fetal pulse oximetry sub partu. Experiences with the Ohmeda Biox 3700 and the Baxter Asat 1000 Pulse Oximeter].

    Science.gov (United States)

    Golaszewski, T; Frigo, P; Ulm, M; Lee, A; Gruber, W; Rafolt, D; Heger, G; Golaszewski, S

    1993-01-01

    In this study oxygen saturation was measured at the presenting part of the fetus during labour. We used two different reflectance sensors together with two different pulse oximeters. The Baxter Asat 100 displayed a 25% lower functional oxygen saturation of haemoglobin (SaO2) compared to the Ohmeda Biox 3700 pulse oximeter. The mean duration of application using the Ohmeda Biox 3700 together with an adapted finger sensor was 36 min (SD +/- 17 min), an effective measurement was achieved for 15 min (SD +/- 9 min). The mean duration of application using the Baxter Asat 100 together with a commercial Baxter reflex sensor was 88 min (SD +/- 96 min), an effective measurement was attained for 73 min (SD +/- 77 min).

  12. Examiner's finger-mounted fetal tissue oximetry

    Science.gov (United States)

    Kanayama, Naohiro; Niwayama, Masatsugu

    2014-06-01

    The best way to assess fetal condition is to observe the oxygen status of the fetus (as well as to assess the condition of infants, children, and adults). Previously, several fetal oximeters have been developed; however, no instrument has been utilized in clinical practice because of the low-capturing rate of the fetal oxygen saturation. To overcome the problem, we developed a doctor's finger-mounted fetal tissue oximeter, whose sensor volume is one hundredth of the conventional one. Additionally, we prepared transparent gloves. The calculation algorithm of the hemoglobin concentration was derived from the light propagation analysis based on the transport theory. We measured neonatal and fetal oxygen saturation (StO2) with the new tissue oximeter. Neonatal StO was measured at any position of the head regardless of amount of hair. Neonatal StO was found to be around 77%. Fetal StO was detected in every position of the fetal head during labor regardless of the presence of labor pain. Fetal StO without labor pain was around 70% in the first stage of labor and around 60% in the second stage of labor. We concluded that our new concept of fetal tissue oximetry would be useful for detecting fetal StO in any condition of the fetus.

  13. Pulse oximetry: fundamentals and technology update

    Directory of Open Access Journals (Sweden)

    Nitzan M

    2014-07-01

    Full Text Available Meir Nitzan,1 Ayal Romem,2 Robert Koppel31Department of Physics/Electro-Optics, Jerusalem College of Technology, Jerusalem, Israel; 2Pulmonary Institute, Shaare Zedek Medical Center, Jerusalem, Israel; 3Neonatal/Perinatal Medicine, Cohen Children's Medical Center of New York/North Shore-LIJ Health System, New Hyde Park, NY, United StatesAbstract: Oxygen saturation in the arterial blood (SaO2 provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oximeter sensor, utilizing in vitro measurement of SaO2 in extracted arterial blood by means of co-oximetry. Due to the discrepancy between the measurement of SaO2 by pulse oximetry and the invasive technique, the former is denoted as SpO2. Manufacturers of pulse oximeters generally claim an accuracy of 2%, evaluated by the standard deviation (SD of the differences between SpO2 and SaO2, measured simultaneously in healthy subjects. However, an SD of 2% reflects an expected error of 4% (two SDs or more in 5% of the examinations, which is in accordance with an error of 3%–4%, reported in clinical studies. This level of accuracy is sufficient for the detection of a significant decline in respiratory function in patients, and pulse oximetry has been accepted as a reliable technique for that purpose. The accuracy of SpO2 measurement is insufficient in several situations, such as critically ill patients receiving supplemental oxygen, and can be hazardous if it leads to elevated values of oxygen partial pressure in blood. In particular, preterm newborns are vulnerable to retinopathy of prematurity induced by high oxygen concentration in the blood. The low accuracy of SpO2 measurement in critically ill patients and newborns

  14. Pulse oximetry in bronchiolitis: is it needed?

    Directory of Open Access Journals (Sweden)

    Hendaus MA

    2015-10-01

    Full Text Available Mohamed A Hendaus,1,2 Fatima A Jomha,3 Ahmed H Alhammadi,1,2 1Department of Pediatrics, General Pediatrics Division, Hamad Medical Corporation, 2Weill-Cornell Medical College, Doha, Qatar; 3School of Pharmacy, Lebanese International University, Khiara, Lebanon Abstract: Infants admitted to health-care centers with acute bronchiolitis are frequently monitored with a pulse oximeter, a noninvasive method commonly used for measuring oxygen saturation. The decision to hospitalize children with bronchiolitis has been largely influenced by pulse oximetry, despite its questionable diagnostic value in delineating the severity of the illness. Many health-care providers lack the appropriate clinical fundamentals and limitations of pulse oximetry. This deficiency in knowledge might have been linked to changes in the management of bronchiolitis. The aim of this paper is to provide the current evidence on the role of pulse oximetry in bronchiolitis. We discuss the history, fundamentals of operation, and limitations of the apparatus. A search of the Google Scholar, Embase, Medline, and PubMed databases was carried out for published articles covering the use of pulse oximetry in bronchiolitis. Keywords: bronchiolitis, children, monitor, oxygen

  15. Continuous pulse oximetry in acute hemiparetic stroke

    NARCIS (Netherlands)

    Elting, JW; Stewart, R; den Arend, A; De Keyser, J; Sulter, G.

    2000-01-01

    Background and purpose: Hypoxemia can adversely affect ischemic brain tissue in laboratory animals. The aim of this study was to assess the Value of early continuous monitoring with pulse oximetry in detecting arterial oxygen desaturations in patients with acute hemiparetic stroke, and the effects

  16. Optimal filter bandwidth for pulse oximetry

    Science.gov (United States)

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.

  17. Pulsioximetría fetal. Nuevo método de control fetal intraparto: Estudio comparativo con técnicas invasivas acerca del bienestar fetal Fetal pulse oximetry. Intrapartum foetal hipoxia evaluation: Comparative study with invasive techniques concerning foetal welfare

    Directory of Open Access Journals (Sweden)

    I. Fernández Andrés

    2004-08-01

    Full Text Available Fundamento. La pulsioximetría, técnica que mide de forma continua la saturación de oxígeno en sangre (%SpO2, se ha convertido en un método de monitorización estándar en anestesia, cuidados intensivos, neonatología, etc., pudiendo llegar a ser útil a los obstetras en la monitorización del bienestar fetal durante el parto. Tiene la ventaja de ser mínimamente invasiva y fácil de usar. La saturación de hemoglobina fetal oxigenada es un buen parámetro para medir el contenido-déficit fetal de oxígeno. Una saturación menor del 30% durante un periodo de tiempo superior a 10 minutos se correlaciona con una pHmetría de micromuestra de cuero cabelludo fetal Pulse oximetry is a technique that continuously measures the blood oxygen saturation (%SpO2; it has become a standard monitoring method in Anaesthesia, Intensive Care, Neonatology, etc; and it can be helpful in Obstetrics during delivery to monitor foetal welfare. Its advantages are that it is minimally invasive and easy to use. Moreover, SpO2 is a good parameter for measuring oxygen carriage. A saturation below 30% during a time period over 10 minutes is correlated with an acid-base equilibrium (ABE of foetal scalp blood sample below 7.20, and it is predictive of worse perinatal outcomes. The objectives are: 1. The combined use of both techniques (foetal pulse oximetry and ABE, provides equivalent perinatal outcomes but decreases the Caesarean Intrapartum Rate due to suspicion of a loss of foetal welfare. 2. A correlation was found between foetal pulse oximetry and acid-base equilibrium data such as pH, pO2 and EB. Subjects and methods. Data was gathered on two groups of eighty patients. In the first group we carried out a follow up of delivery under serialized pH-metry, and in the other group, control of the foetuses was carried out in a combined form with pHmetry and pulse oximetry. Results. Statistically significant results were obtained concerning delivery in the comparative study

  18. Pulse Oximetry as a Medical Physics Practical on School Trips

    Science.gov (United States)

    Gibson, Adam P.; Chandra, Elizabeth; Chandra, Manik

    2009-01-01

    We have measured blood oxygenation levels in a group of 14 people (8 young people and 6 adults) on a physically demanding expedition to Mt Kenya. Blood oxygenation was measured at 11 different altitudes between 1910 and 4985 m using pulse oximetry. We found that pulse oximetry was suitable for use on a youth expedition and we were able to show…

  19. Advanced Pulse Oximetry System for Remote Monitoring and Management

    Directory of Open Access Journals (Sweden)

    Ju Geon Pak

    2012-01-01

    Full Text Available Pulse oximetry data such as saturation of peripheral oxygen (SpO2 and pulse rate are vital signals for early diagnosis of heart disease. Therefore, various pulse oximeters have been developed continuously. However, some of the existing pulse oximeters are not equipped with communication capabilities, and consequently, the continuous monitoring of patient health is restricted. Moreover, even though certain oximeters have been built as network models, they focus on exchanging only pulse oximetry data, and they do not provide sufficient device management functions. In this paper, we propose an advanced pulse oximetry system for remote monitoring and management. The system consists of a networked pulse oximeter and a personal monitoring server. The proposed pulse oximeter measures a patient’s pulse oximetry data and transmits the data to the personal monitoring server. The personal monitoring server then analyzes the received data and displays the results to the patient. Furthermore, for device management purposes, operational errors that occur in the pulse oximeter are reported to the personal monitoring server, and the system configurations of the pulse oximeter, such as thresholds and measurement targets, are modified by the server. We verify that the proposed pulse oximetry system operates efficiently and that it is appropriate for monitoring and managing a pulse oximeter in real time.

  20. Variations in physician interpretation of overnight pulse oximetry monitoring.

    Science.gov (United States)

    Ramsey, Rory; Mehra, Reena; Strohl, Kingman P

    2007-09-01

    Overnight pulse oximetry is commonly used for hypoxemia evaluation in patients with COPD and sleep-disordered breathing. There is little information regarding its impact on physician decision making, and therefore an important measure of its clinical utility is untested and unknown. The aim of this study was to describe physician interpretation, use, and opinions regarding overnight pulse oximetry. Forty-one pulmonary physicians and fellows participated in structured interviews consisting of three oximetry record interpretations, oral responses to a standard question set, and a questionnaire. Qualitative data were analyzed using an open coding process. Quantitative data were assessed for distributions. Four measures were consistently used by the majority of physicians in record interpretation: background information, arterial oxygen saturation measured by pulse oximetry (Spo(2)) waveform and pattern, and time spent with Spo(2) 60% consensus. There was a wide range of opinions on important matters related to this test, including test utility, indications, variables considered most important for interpretation, and criteria for nocturnal oxygen prescription. Forty-one physicians provided 35 different opinions on when nocturnal supplemental oxygen should be initiated. The variation in physician interpretation, use, and opinions regarding overnight pulse oximetry calls into question its clinical utility and underscores a need for standardization of presentation, training, and interpretation.

  1. Digital pressure ulcer after pulse oximetry [Digitales Druckulkus nach Pulsoxymetrie

    Directory of Open Access Journals (Sweden)

    Zeplin, Philip H.

    2013-06-01

    Full Text Available [english] In emergency medical service, in intensive care unit and anaesthesia oxygenation is monitored with pulse oximetry apparatus. Pulse oximetry probe is usually attached to the finger, toe or earlobe. To the best of our knowledge this is the first case report describing the occurrence of a pressure ulcer after finger pulse oximetry measurement.[german] Sowohl in der Notfall- und Intensivmedizin als auch in der Anästhesie wird die Sauerstoffsättigung des Blutes mit Pulsoxymetern ermittelt. Diese Pulsoxymeter werden üblicherweise an den Fingern, den Zehen oder dem Ohrläppchen angebracht. Wir beschreiben einen Fall, bei dem es nach Anlage eines Fingerclip-Pulsoxymeters zur Ausbildung eines operationsbedürftigen Druckulkus kam.

  2. Feasibility and accuracy of nasal alar pulse oximetry.

    Science.gov (United States)

    Morey, T E; Rice, M J; Vasilopoulos, T; Dennis, D M; Melker, R J

    2014-06-01

    The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve oxyhaemoglobin saturations of 70-100% measured by traditional co-oximetry from radial artery samples. Concurrent alar and finger pulse oximetry values were measured using probes designed for these sites. Data were analysed using the Bland-Altman method for multiple observations per subject. Bias, precision, and accuracy root mean square error (ARMS) over a range of 70-100% were significantly better for the alar probe compared with a standard finger probe. The mean bias for the alar and finger probes was 0.73% and 1.90% (Palar and finger probes, respectively. The within/between-subject variation for the alar and finger probes were 1.14/1.57% and 1.87/1.47%, respectively. The limits of agreement were 3.96/-2.50% and 5.48/-1.68% for the alar and finger probes, respectively. Nasal alar pulse oximetry is feasible and demonstrates accurate pulse oximetry values over a range of 70-100%. The alar probe demonstrated greater accuracy compared with a conventional finger pulse oximeter. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Pulse oximetry : technology to reduce child mortality in developing countries

    NARCIS (Netherlands)

    Duke, T.; Subhi, R.; Peel, D.; Frey, B.

    2009-01-01

    The causes of hypoxaemia in children include the commonest causes of childhood illness: pneumonia and other acute respiratory infections, and neonatal illness, particularly sepsis, low birthweight, birth asphyxia and aspiration syndromes. The systematic use of pulse oximetry to monitor and treat chi

  4. Finger blood content, light transmission, and pulse oximetry errors.

    Science.gov (United States)

    Craft, T M; Lawson, R A; Young, J D

    1992-01-01

    The changes in light emitting diode current necessary to maintain a constant level of light incident upon a photodetector were measured in 20 volunteers at the two wavelengths employed by pulse oximeters. Three states of finger blood content were assessed; exsanguinated, hyperaemic, and normal. The changes in light emitting diode current with changes in finger blood content were small and are not thought to represent a significant source of error in saturation as measured by pulse oximetry.

  5. Knowledge of pulse oximetry among medical and nursing staff

    Directory of Open Access Journals (Sweden)

    Dimitrios Kosmidis

    2007-04-01

    Full Text Available The pulse oximetry is a widely used non invasive method for monitoring the arterial oxygenation. The doctors and the nurses are persons which are in charge for right interpretation of measurements, receiving suitable interventions for the management of patients. Aim: To assess nurses' and doctors' knowledge of pulse oximetry and identify training needs. Material and method: Participants in this study were 376 doctors and nurses from critical and general care settings in seven hospitals in Greece. The data collection was done through a self-administered questionnaire. Frequency of use, critical care experience, and opinions about education needs were included in demographic data. The knowledge test consisted of a 15 item, multiple-choice questionnaire, designed by researchers based on international bibliography. Results: A 70,7% of participants, use pulse oximeter often and 66,3% consider that is very useful in daily clinical practice. 83,7% didn't have some type of past education while more than 81,4% believes that they need further education. The average score for all (on a 15-point scale was 8,5. Ιn particular, the average score for each team had as follows: 10,5±2,7 for the specialized doctors, 9,6±3,1 for residents, 7,8±3,3 for the nurses and 7,4±3,4 for the nurse assistants. Low percentages of right answers were observed mainly in the questions about principles on which the pulse oximetry are based, clinical application and limitations, as well as normal ranges. Conclusion: The comprehension of pulse oximetry is insufficient, mainly in the nursing staff while totally is observed the need for further education.

  6. LED power reduction trade-offs for ambulatory pulse oximetry.

    Science.gov (United States)

    Peláez, Eduardo Aguilar; Villegas, Esther Rodríguez

    2007-01-01

    The development of ambulatory arterial pulse oximetry is key to longer term monitoring and treatment of cardiovascular and respiratory conditions. The investigation presented in this paper will assist the designer of an ambulatory pulse oximetry monitor in minimizing the overall LED power consumption (P LED,TOT) levels by analyzing the lowest achievable limit as constrained by the optical components, circuitry implementation and final SpO2 reading accuracy required. LED duty cycle (D LED) reduction and light power (P LED,ON) minimization are proposed as methods to reduce P LED,TOT. Bandwidth and signal quality calculations are carried out in order to determine the required P LED,TOT as a function of the different noise sources.

  7. EVALUATION OF CONDITION OF THE PULP BY PULSE OXIMETRY.

    Directory of Open Access Journals (Sweden)

    Dimitar Kosturkov

    2015-12-01

    Full Text Available Purpose: To conduct pulse oximetry (PO and electric pulp test (EPT on intact frontal teeth in clinically healthy patients aged between 18 and 25 years who do not have periodontal disease. Material/Methods: To achieve the aim 1058 teeth of 31 patients were studied. The following inclusion criteria for the study were set: 1. Age – 18-25 years. 2. Clinically healthy patient, who does not have any systemic diseases, do not take any medicine systematically. 3. Intact frontal teeth – without carious lesions, restorations or root canal treatment. 4. Lack of periodontal disease. Research was conducted with a pulse oximeter Contec™ - CMS60D and a custom made probe holder. Results: Average values obtained by pulse oximetry in upper jaw vary between 83% and 85%. In lower jaw – between 82% and 85%. 99% is the maximum and 48% is the minimum registered value. The average value of the measurement of all the teeth is 84%. The average saturation measured on the small finger of the right hand of the patient is 98%. The average value of EPT for all teeth is 4 μA. The maximum measured value is 20 μA, and the minimum - 1 μA. Conclusions: 1. Adequate study of the pulp includes two complementary methods – electric pulp test (evaluation of innervation and pulse oximetry (assessment of pulp microcirculation. 2. Teeth that are larger in size have larger values of PO and EPT, which is in direct relation to the size of their pulp chamber. 3. The total saturation, measured in the little finger of the right hand is greater than the one of the teeth.

  8. The Impact of Reduced Pulse Oximetry Use on Alarm Frequency.

    Science.gov (United States)

    Schondelmeyer, Amanda C; Brady, Patrick W; Sucharew, Heidi; Huang, Guixia; Hofacer, Kelsey E; Simmons, Jeffrey M

    2016-04-01

    Concerns about alarm fatigue prompted The Joint Commission to issue a Sentinel Event Alert urging hospitals to minimize alarms. We previously conducted a quality improvement project on a single unit that reduced time on continuous pulse oximetry, a common source of physiologic monitor alarms, for patients with wheezing (ie, asthma and bronchiolitis, wheezing-associated respiratory infections). To study the impact of our improvement work on overall physiologic monitor alarm frequency for these patients. This was a retrospective cohort study at a freestanding children's hospital over an 8-week period. We compared alarm count, including respiratory, cardiac, and pulse oximetry alarms, for patients admitted to the intervention unit with the alarm count for similar patients on a control unit by using the Wilcoxon rank sum test. We used negative binomial regression to evaluate differences in alarm count between the units, adjusting for age, medical comorbidity, and length of stay. There were 101 patients on the intervention unit and 46 patients on the control unit. The percentage of patients with medical comorbidities was significantly higher on the intervention unit (P=.01). Median alarm count per day for patients on the intervention unit was lower; however, this difference was not statistically significant (71 vs 76 alarms per patient-day, P=.29). The multivariable model estimated a nonsignificant 6.4-count decrease in alarms for patients on the intervention unit. Reducing continuous pulse oximetry use alone may not make substantial reductions in overall alarm counts. Even on our intervention unit, alarm burden remained quite high. Copyright © 2016 by the American Academy of Pediatrics.

  9. Assessment of the calibration curve for transmittance pulse-oximetry

    Science.gov (United States)

    Doronin, A.; Fine, I.; Meglinski, I.

    2011-11-01

    Optical/laser modalities provide a broad variety of practical solutions for clinical diagnostics and therapy in a range from imaging of single cells and molecules to non-invasive biopsy of specific biological tissues and organs tomography. Near-infrared transmittance pulse oximetry with laser diodes is the accepted standard in current clinical practice and widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. Conceptual design of practical pulse oximetry systems requires careful selection of various technical parameters, including intensity, wavelength, beam size and profile of incident laser radiation, size, numerical aperture of the detector, as well as a clear understanding of how the spatial and temporal structural alterations in biological tissues can be linked with and can be distinguished by variations of these parameters. In current letter utilizing state-of-the-art NVIDEA CUDA technology, a new object oriented programming paradigm and on-line solutions we introduce a computational tool applied for human finger transmittance spectra simulation and assessment of calibration curve for near-infrared transmitted pulseoximetry.

  10. Intrauterine Methylene Blue Injection Influences the Accuracy of Pulse Oximetry Readings

    Directory of Open Access Journals (Sweden)

    Fuh-Cheng Yeh

    2005-12-01

    Conclusions: Intraoperative administration of methylene blue may induce false low readings on pulse oximetry. The patient was not hypoxemic. If there is any doubt, arterial blood gas analysis should be done to ensure that the patient is well oxygenated.

  11. The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.

    Science.gov (United States)

    Foglia, Elizabeth E; Whyte, Robin K; Chaudhary, Aasma; Mott, Antonio; Chen, Jodi; Propert, Kathleen J; Schmidt, Barbara

    2017-03-01

    To compare pulse oximetry measurement bias between infants with hypoxemia with either dark skin or light skin with Masimo Radical 7 and Nellcor Oximax. There was no significant difference in systematic bias based on skin pigment for either oximeter.

  12. Neonatal pulse oximetry screening improves detecting of critical congenital heart disease

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-jing; HUANG Guo-ying

    2013-01-01

    Objective Life-threatening critical congenital heart disease (cCHD) is often not detected in the neonatal period.Unrecognized cCHD results in high morbidity and mortality rates.As a non-invasive,convenient,quick and accurate measuring method,pulse oximetry is considered to be a promising strategy to screen for cCHD in neonates.This article is a review on the neonatal pulse oximetry screening for cCHD.Data sources Articles on neonatal pulse oximetry screening for cCHD were accessed from PubMed,using keywords including congenital heart defects,neonatal screening and oximetry.Study selection Original articles and critical reviews selected were relevant to the review's theme.Results The factors in the course of implementation,including threshold for positive pulse-oximetry screening results,the pulse oximeters used,timing of the screening,and the measuring position,influence the accuracy of the screening.It is recommended that the screening is completed on the second day of life,before hospital discharge.Motion-tolerant pulse oximeters,which can also be applied to measure the saturation in low-perfusion conditions,should be used.The probe should be put on both the right hand and on one foot.Thresholds of <95% in either limb or a difference of >3% between the limbs as a positive result may be appropriate.It should be emphasized that pulse-oximetry screening cannot be used as the only way to detect cCHD,clinical examination is also important in this situation.Cost-benefit analysis in the United Kingdom revealed it was plausible to use pulse oximetry as an adjunct to clinical examination.However,it is still controversial as to whether pulse oximetry can be used as a routine screening method for cCHD in neonates.Conclusions Neonatal pulse oximetry screening improves detection of cCHD.Further studies should be carried out before it becomes one of the routine newborn screening programs.

  13. Diagnosis of PLMD from increased pulse rate variability on overnight oximetry.

    Science.gov (United States)

    Krishnaswamy, Uma M; Higgins, Sean E; Kosky, Christopher A; Delacy, Simone; Williams, Adrian J

    2010-01-01

    This study was undertaken in a group of patients with periodic limb movement disorder (PLMD) to assess whether the presence of increased pulse rate variability (PRV) without desaturation on overnight oximetry was suggestive of the occurrence of periodic limb movements (PLMs). Seventy sleepy patients with a polysomnographic diagnosis of PLMD and 25 controls with obstructive sleep apnea were included in this retrospective study. All patients had undergone initial domiciliary oximetry and subsequent polysomnography (PSG). The oximetry tracings were independently interpreted by five sleep unit personnel for the presence of increased PRV. Further, the association between increased PRV and PLMs was evaluated in the summary graph of the PSG. Fifty seven (81.4%) patients had definite evidence of increased PRV without episodes of desaturation on initial oximetry, which was later confirmed to be due to PLMs on PSG. 13 (18.6%) patients had no PRV on oximetry and PSG but had PLMD. The inter-interpreter concurrence in suspecting a diagnosis of PLMD based on oximetry alone was more than 80% in 64 (91%) patients. The presence of isolated increased PRV on overnight oximetry is a valuable tool in suspecting nonsleep apnea disorders like PLMD.

  14. An Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry

    DEFF Research Database (Denmark)

    Haahr, Rasmus Grønbek; Duun, Sune Bro; Toft, Mette H.;

    2012-01-01

    We report the development of an Electronic Patch for wearable health monitoring. The Electronic Patch is a new health monitoring system incorporating biomedical sensors, microelectronics, radio frequency (RF) communication, and a battery embedded in a 3-dimensional hydrocolloid polymer...... photodiode to enable low power consumption by the light emitting components. The Electronic Patch has a disposable part of soft adhesive hydrocolloid polymer and a reusable part of hard polylaurinlactam. The disposable part contains the battery. The reusable part contains the reflectance pulse oximetry....... In this paper the Electronic Patch is demonstrated with a new optical biomedical sensor for reflectance pulse oximetry so that the Electronic Patch in this case can measure the pulse and the oxygen saturation. The reflectance pulse oximetry solution is based on a recently developed annular backside silicon...

  15. Pulse oximetry for screening critical congenital heart disease in newborns

    Institute of Scientific and Technical Information of China (English)

    CHEN Cui-ying; WU Shu-yan; YOU Ke-li; CHEN Guan-di; LI Zhi-gang

    2016-01-01

    Background Pulse oximetry screening (POS) has been proposed as an effective,noninvasive,inexpensive tool allowing earlier diagnosis of critical congenital heart disease (CCHD).However,most neonates are discharged from the hospital without this evaluation in China.This study aimed at assessing the feasibility of POS for newborns in detecting CCHD in the department of obstetrics and neonatal intensive care unit (NICU).Methods POS was performed in 355 neonates born in the department of obstetrics or admitted to the NICU between January 2015 and June 2015.These neonates were divided into normal group,mild congenital heart disease group (MCHD) and CCHD group,according to the result of echocardiography or computerized tomography (CT).The gestational age,birth weight and arterial oxygen saturation (SpO2) were compared among the three groups.The SpO2 value and diagnosis time of the CCHD cases were classified and analyzed.Results The premature birth and low birth weight were the high risk factors of mild congenital heart disease.There was no difference (P > 0.05) in SpO2 between the MCHD group and the normal group.Significant difference in the SpO2 appeared between the CCHD group and the normal group (P < 0.05).Combination of POS and clinical examination can reduce the missing diagnosis rate in screening for CCHD.Conclusions POS incurs very low cost and risk of harm and is not required for special gaining,therefore,an effective way to identify CCHD in neonates.

  16. RANCANG BANGUN PULSE OXIMETRY MENGGUNAKAN ARDUINO SEBAGAI DETEKSI KEJENUHAN OKSIGEN DALAM DARAH

    Directory of Open Access Journals (Sweden)

    Umi Salamah

    2016-12-01

    Full Text Available Kekurangan atau kelebihan oksigen dalam darah akan menimbulkan penyakit dan gangguan kerja tubuh. Pada tingkat tertentu, penyakit tersebut dapat meninbulkan resiko kematian. Oleh karena itu, informasi tentang kejenuhan oksigen dalam darah menjadi hal yang penting untuk dideteksi. Salah satu insturmentasi yang digunakan untuk memantau kejenuhan oksigen dalam darah adalah dengan pulse oximetry. Dalam penelitian ini dirancang bangun pulse oximetry berbasis personal computer menggunakan LED merah dan inframerah sebagai sumber cahaya sedang sensor cahaya yang digunakan adalah fotodioda. Pulse oximetry yang dirancang adalah instrumentasi non invasive yang mana driver LED diletakkan pada ujung jari. Cahaya LED yang terserap jari akan menjadi sinyal yang diumpankan ke fotodioda yang selanjutnya sinyal tersebut akan diubah menjadi sinyal digital oleh Arduino dan diproses lebih lanjut oleh personal computer untuk menampilkan grafik pulse oximetry tersebut. Perangkat lunak untuk mengolah data keluaran Arduino menggunakan Delphi 7, Microsoft Exel dan Mat Lab sebagai perangkat lunaknya. Hasil penelitian ini diperoleh sinyal Photopletysmography (PPG Ujung Jari yang representatif  dengan sinyal PPG referensi. Pengujian pulse oximetry yang telah dirancang adalah 16 dengan sampel uji random. Dari sampel tersebut, diperoleh 13 sampel uji berada pada prosentase kejenuhan oksigen normal dan 3 sampel uji berada pada prosentase kejenuhan oksigen tidak normal.

  17. Evaluating the impact of pulse oximetry on childhood pneumonia mortality in resource-poor settings.

    Science.gov (United States)

    Floyd, Jessica; Wu, Lindsey; Hay Burgess, Deborah; Izadnegahdar, Rasa; Mukanga, David; Ghani, Azra C

    2015-12-01

    It is estimated that pneumonia is responsible for 15% of childhood deaths worldwide. Recent research has shown that hypoxia and malnutrition are strong predictors of mortality in children hospitalized for pneumonia. It is estimated that 15% of children under 5 who are hospitalized for pneumonia have hypoxaemia and that around 1.5 million children with severe pneumonia require oxygen treatment each year. We developed a deterministic compartmental model that links the care pathway to disease progression to assess the impact of introducing pulse oximetry as a prognostic tool to distinguish severe from non-severe pneumonia in under-5 year olds across 15 countries with the highest burden worldwide. We estimate that, assuming access to supplemental oxygen, pulse oximetry has the potential to avert up to 148,000 deaths if implemented across the 15 countries. By contrast, integrated management of childhood illness alone has a relatively small impact on mortality owing to its low sensitivity. Pulse oximetry can significantly increase the incidence of correctly treated severe cases as well as reduce the incidence of incorrect treatment with antibiotics. We also found that the combination of pulse oximetry with integrated management of childhood illness is highly cost-effective, with median estimates ranging from US$2.97 to $52.92 per disability-adjusted life year averted in the 15 countries analysed. This combination of substantial burden reduction and favourable cost-effectiveness makes pulse oximetry a promising candidate for improving the prognosis for children with pneumonia in resource-poor settings.

  18. Pulse Oximetry in the Physics Lab: A Colorful Alternative to Traditional Optics Curricula

    Science.gov (United States)

    Kutschera, Ellynne; Dunlap, Justin C.; Byrd, Misti; Norlin, Casey; Widenhorn, Ralf

    2013-11-01

    We designed a physics laboratory exercise around pulse oximetry, a noninvasive medical technique used to assess a patient's blood oxygen saturation. An alternative to a traditional optics and light lab, this exercise teaches the principles of light absorption, spectroscopy, and the properties of light, while simultaneously studying a common medical device. Pulse oximeters are ubiquitous in clinical environments; many people who have undergone surgery or visited a hospital environment have experienced the use of this device, making it a good candidate for an investigative lab. The experiment elicits the creative process of device development from students as they conduct measurements using a blood analog that reconstructs the principles of pulse oximetry.

  19. High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors

    DEFF Research Database (Denmark)

    Duun, Sune Bro; Haahr, Rasmus Grønbek; Hansen, Ole;

    2010-01-01

    The development of annular photodiodes for use in a reflectance pulse oximetry sensor is presented. Wearable and wireless body sensor systems for long-term monitoring require sensors that minimize power consumption. We have fabricated large area 2D ring-shaped silicon photodiodes optimized....../2) cm(-1) are achieved. The photodiodes are incorporated into a wireless pulse oximetry sensor system embedded in an adhesive patch presented elsewhere as 'The Electronic Patch'. The annular photodiodes are fabricated using two masked diffusions of first boron and subsequently phosphor. The surface...

  20. EARLY DETECTION OF CRITICAL CONGENITAL HEART DISEASE IN NEW BORNS USING PULSE OXIMETRY SCREENING

    Directory of Open Access Journals (Sweden)

    ShahForum,Chatterjee Rajib, PatelPrashant C, Kunkulol Rahul R

    2015-01-01

    Full Text Available Background: Congenital heart diseases which are dependent on the ductusarteriosus to maintain adequate oxygenation or systemic blood flow are termed as a critical congenital heart disease (CCHD. Delay in the diagnosis of CCHD is the major cause leading to morbidity and mortality in newborn infants. Clinical evaluation is likely to miss the diagnosis in first few hours of hospital stay after birth due to absence of signs and symptoms of CCHD. In the absence of clinical findings during early neonatal period, the best parameter that can be assessed is the detection of hypoxemia by pulse oximetry screening. Objectives: To record the value of Pulse Oximetry within 24 hours of birth and evaluate Pulse Oximetry as screening tool for early diagnosis of CCHD. &Methods: Longitudinal descriptive study was conducted on total 700 intramural neonates, satisfying the inclusion and exclusion criteria, who were evaluated within 24 hours of birth with currently available pulse oximeter, after the Institutional Ethical Committee approval. The study was conducted over a period of 4 months. Part-A: Neonatal Case Record, Part-B: Pulse Oximetry Screening Record, Part-C: Clinical Examination Record, Part-D: Echocardiography Record. Results and Conclusion: Total 700 neonates were screened by pulse oximeter with consecutive sampling method. 4 (0.57% subjects were detected to have positive screen and the diagnosis was confirmed by echocardiography. Study revealed that Pulse Oximetry Screening can be an important primary screening tool in routine neonatal care for early detection of Critical Congenital Heart Diseases particularly in rural setup

  1. An analysis on the theory of pulse oximetry by Monte Carlo simulation

    Science.gov (United States)

    Fan, Shangchun; Cai, Rui; Xing, Weiwei; Liu, Changting; Chen, Guangfei; Wang, Junfeng

    2008-10-01

    The pulse oximetry is a kind of electronic instrument that measures the oxygen saturation of arterial blood and pulse rate by non-invasive techniques. It enables prompt recognition of hypoxemia. In a conventional transmittance type pulse oximeter, the absorption of light by oxygenated and reduced hemoglobin is measured at two wavelength 660nm and 940nm. But the accuracy and measuring range of the pulse oximeter can not meet the requirement of clinical application. There are limitations in the theory of pulse oximetry, which is proved by Monte Carlo method. The mean paths are calculated in the Monte Carlo simulation. The results prove that the mean paths are not the same between the different wavelengths.

  2. Pulse Oximetry in the Physics Lab: A Colorful Alternative to Traditional Optics Curricula

    Science.gov (United States)

    Kutschera, Ellynne; Dunlap, Justin C.; Byrd, Misti; Norlin, Casey; Widenhorn, Ralf

    2013-01-01

    We designed a physics laboratory exercise around pulse oximetry, a noninvasive medical technique used to assess a patient's blood oxygen saturation. An alternative to a traditional optics and light lab, this exercise teaches the principles of light absorption, spectroscopy, and the properties of light, while simultaneously studying a common…

  3. Feasibility of pulse oximetry in the initial prehospital management of victims of drowning : A preliminary study

    NARCIS (Netherlands)

    Montenij, Leonard J.; de Vries, Wiebe; Schwarte, Lothar; Bierens, Joost J. L. M.

    2011-01-01

    Aim: Immediate delivery of oxygen is the most important treatment for victims of drowning at the rescue site. Monitoring oxygen saturation with pulse oximetry is potentially useful, but its use may be limited by poor peripheral perfusion due to hypothermia. This preliminary study explores the feasib

  4. REFLECTANCE PULSE OXIMETRY AT THE FOREHEAD IMPROVES BY PRESSURE ON THE PROBE

    NARCIS (Netherlands)

    DASSEL, ACM; GRAAFF, R; SIKKEMA, M; ZIJLSTRA, WG; AARNOUDSE, JG

    1995-01-01

    In this study, we investigated the possibility of improving reflectance (back-scatter) pulse oximetry measurements by pressure applied to the probe. Optimal signal detection, with the probe applied to an easily accessible location, is important to prevent erroneous oxygen saturation readouts. At the

  5. A Novel Photodiode for Reflectance Pulse Oximetry in low-power applications

    DEFF Research Database (Denmark)

    Haahr, Rasmus Grønbek; Duun, Sune; Birkelund, Karen;

    2007-01-01

    The amount of light collected is crucial for low-power applications of pulse oximetry. In this work a novel ring-shaped backside photodiode has been developed for a wearable reflectance pulse oximeter. The photodiode is proven to work with a dual LED with wavelengths of 660 nm and 940 nm. For the......The amount of light collected is crucial for low-power applications of pulse oximetry. In this work a novel ring-shaped backside photodiode has been developed for a wearable reflectance pulse oximeter. The photodiode is proven to work with a dual LED with wavelengths of 660 nm and 940 nm....... For the purpose of continuously monitoring vital signs of a human, a temperature sensor is integrated onto the chip containing the photodiode. This biomedical multisensor chip is made for integration into "the electronic patch", an autonomous monitoring system for humans....

  6. Next-generation pulse oximetry. Focusing on Masimo's signal extraction technology.

    Science.gov (United States)

    2000-10-01

    Pulse oximeters are used to determine trends in patients' blood oxygen saturation and to warn of dangerous saturation levels. But conventional pulse oximetry has some inherent limitations. For example, it has difficulty monitoring patients who are moving or who have poor perfusion; it is also subject to interference from certain visible and infrared light sources. Over the past several years, a number of companies have developed advanced signal-processing techniques that allow pulse oximeters to overcome many of these limitations. We refer to such new technologies as next-generation pulse oximetry. In this Evaluation, we focus on the first next-generation technology to have reached the market: Masimo Corporation's Signal Extraction Technology (SET). We designed our study of Masimo SET to address the main question that needs to be asked of any next-generation technology: How well does it compare to conventional pulse oximetry? Specifically, how well does it perform when a patient is moving or being moved, when a patient is poorly perfused, or when certain types of light strike the sensor while it is attached to or detached from the patient? We also examined one type of sensor used with this product, comparing it to conventional tape-on sensors for comfort and durability. Several other next-generation pulse-oximeter products have become available since we began this study. We are currently evaluating these products and will publish our findings in the near future. A list of the products, including a brief description of each, is included in this article. Pulse oximeters are used to determine trends in patients' blood oxygen saturation and to warn against dangerous saturation levels. These monitors are often vital in helping to ensure patient safety, especially for critically ill patients, pediatric patients, and neonates. But conventional pulse oximetry has some inherent limitations--most significantly, it has difficulty monitoring patients who are moving or who have

  7. The Comparison of Pulse Oximetry and Cardiac Catheterization in Managing the Treatment of Children with Congenital Heart Disease

    Directory of Open Access Journals (Sweden)

    R Abbasi

    2015-03-01

    Full Text Available Bachground & aim: Pulse oximetry and cardiac catheterization are concerned in the treatment of children with congenital heart disease. Diagnosis of arterial oxygen saturation in patients with congenital heart disease (CHD can be used to assess and manage their effecacy. The purpose of this study was to compare pulse oximetry and cardiac catheterizations in treatment manage of children with congenital heart disease. Methods: In the present cross sectional study, 110 patients with cyanic and non syani heart disease were studied undergoing right and left heart catheterization by pulse oximetry of index finger and simultaneously, oxygen saturation was measured by cardiac catheterization. Data were analyzed with SPSS software by using Pearson correlation and linear regression. Results: A significant correlation was seen between arterial oxygen saturation measured by pulse oximetry and arterial oxygen saturation (p<0.0001 as well as heart rate, electrocardiogram and pulse oximetry (p<0.0001 respectively. Furthermore, the presence of cyanosis (p=0.001, digital clubbing of the fingers ((p=0.001, low oxygen saturation in the superior vena cava and right atrium (p=0.002 can reduce the accuracy of pulse oximetry for detection of arterial oxygen saturation. The mean right atrial pressure can effect on accuracy of pulse oximetry to detect heartbeat (p=0.034. Maximum sensitivity and specificity for detection of pulse oximetry oxygen saturation was 88 % and 88 heart rate per minute. Conclusion: Pulse oximetric is a useful tool for estimating the arterial oxygen saturation and heart rate in children with congenital heart disease (CHD and is a non-invasive method in comparison with cardiac catheterization. Key words: Pulse oximeter, Congenital Heart Disease, Cardiac Catheterization

  8. Lung cancer symptoms and pulse oximetry in the prognostic assessment of patients with lung cancer

    Directory of Open Access Journals (Sweden)

    Harada Cecilia M

    2005-07-01

    Full Text Available Abstract Background Medical oncologists continue to use performance status as a proxy for quality of life (QOL measures, as completion of QOL instruments is perceived as time consuming, may measure aspects of QOL not affected by cancer therapy, and interpretation may be unclear. The pulse oximeter is widely used in clinical practice to predict cardiopulmonary morbidity after lung resection in cancer patients, but little is known on its role outside the surgical setting. We evaluated whether the Lung Cancer Symptom Scale and pulse oximetry may contribute to the evaluation of lung cancer patients who received standard anticancer therapy. Methods We enrolled forty-one consecutive, newly diagnosed, patients with locally advanced or metastatic lung cancer in this study. We developed a survival model with the variables gender, age, histology, clinical stage, Karnofsky performance status, wasting, LCSS symptom scores, average symptom burden index, and pulse oximetry (SpO2. Results Patient and observer-rated scores were correlated, except for the fatigue subscale. The median SpO2 was 95% (range: 86 to 98, was unrelated to symptom scores, and was weakly correlated with observer cough scores. In a multivariate survival model, SpO2 > 90% and patient scores on the LCSS appetite and fatigue subscales were independent predictors of survival. Conclusion LCSS fatigue and appetite rating, and pulse oximetry should be studied further as prognostic factors in lung cancer patients.

  9. Screening of Obstructive Sleep Apnea with Empirical Mode Decomposition of Pulse Oximetry

    CERN Document Server

    Schlotthauer, Gastón; Larrateguy, Luis D; Milone, Diego H

    2014-01-01

    Detection of desaturations on the pulse oximetry signal is of great importance for the diagnosis of sleep apneas. Using the counting of desaturations, an index can be built to help in the diagnosis of severe cases of obstructive sleep apnea-hypopnea syndrome. It is important to have automatic detection methods that allows the screening for this syndrome, reducing the need of the expensive polysomnography based studies. In this paper a novel recognition method based on the empirical mode decomposition of the pulse oximetry signal is proposed. The desaturations produce a very specific wave pattern that is extracted in the modes of the decomposition. Using this information, a detector based on properly selected thresholds and a set of simple rules is built. The oxygen desaturation index constructed from these detections produces a detector for obstructive sleep apnea-hypopnea syndrome with high sensitivity ($0.838$) and specificity ($0.855$) and yields better results than standard desaturation detection approach...

  10. The use of pulse oximetry as a screening assessment for paediatric neurogenic dysphagia.

    Science.gov (United States)

    Morgan, A T; Omahoney, R; Francis, H

    2008-01-01

    Early screening and intervention for dysphagia is crucial to offset potential outcomes such as compromised nutrition or reduced respiratory function. Current paediatric dysphagia screening tests are subjective with poor sensitivity and specificity. The present study examined whether an objective method, pulse oximetry (measuring oxygen saturation (SpO2) levels), could differentiate between children with and without dysphagia, in relation to (1) Average pre-feeding baseline SpO2 levels; (2) Average feeding SpO2 levels; (3) Average post-feeding SpO2 levels; and (4) The number of events of oxygen desaturation pre-, during and after feeding. Nine participants with chronic neurological disability (CND) (7 F, 2 M) (9; 7-15; 11 years) and nine control participants matched for age (9; 5-16; 0 years) and sex were assessed using a clinical bedside evaluation (CBE) and pulse oximetry. A statistically significant difference was found in SpO2 levels between the two groups (p dysphagia experienced 'events' of SpO2 desaturation during feeding. Pulse oximetry may provide a useful adjunct to the CBE for dysphagia screening, with average SpO2 levels during feeding predicting those with and without dysphagia with moderate levels of sensitivity and specificity. The finding of individual variation in desaturation 'events', however, warrants the provision of further data on large homogenous populations to provide definitive criterion for pathological SpO2 levels associated with dysphagia during oral feeding.

  11. High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors

    Science.gov (United States)

    Duun, Sune; Haahr, Rasmus G.; Hansen, Ole; Birkelund, Karen; Thomsen, Erik V.

    2010-07-01

    The development of annular photodiodes for use in a reflectance pulse oximetry sensor is presented. Wearable and wireless body sensor systems for long-term monitoring require sensors that minimize power consumption. We have fabricated large area 2D ring-shaped silicon photodiodes optimized for minimizing the optical power needed in reflectance pulse oximetry. To simplify packaging, backside photodiodes are made which are compatible with assembly using surface mounting technology without pre-packaging. Quantum efficiencies up to 95% and area-specific noise equivalent powers down to 30 fW Hz-1/2 cm-1 are achieved. The photodiodes are incorporated into a wireless pulse oximetry sensor system embedded in an adhesive patch presented elsewhere as 'The Electronic Patch'. The annular photodiodes are fabricated using two masked diffusions of first boron and subsequently phosphor. The surface is passivated with a layer of silicon nitride also serving as an optical filter. As the final process, after metallization, a hole in the center of the photodiode is etched using deep reactive ion etch.

  12. Improving detection of obstructive sleep apnoea by overnight oximetry in children using pulse rate parameters.

    Science.gov (United States)

    Sahadan, Dg Zuraini; Davey, Margot J; Horne, Rosemary S C; Nixon, Gillian M

    2015-12-01

    Overnight oximetry is a simple tool for investigation of obstructive sleep apnoea (OSA) in children, but only severe cases will be detected, and children with obstructive events resulting in arousal, but not desaturation, will have a normal (inconclusive) result. We hypothesised that pulse rate rises using pulse rate indices per hour (PRI) and pulse rate standard deviation (PR-SD) automatically calculated from commercially available software would improve oximetry as a diagnostic tool. Children having home overnight oximetry for suspected OSA were identified over 12 months, and those with a normal result who went on to have polysomnography (PSG) were included. Oximetry, including PR-SD and PRI (rises of 8, 10 and 15 beats/min per hour), was analyzed using commercially available software. PR parameters were compared between those with OSA (obstructive apnoea-hypopnoea index (OAHI) >1 event/h) and those without OSA. One hundred sixteen children had normal oximetry, of whom 93 (median age 4.5 years; 55 % M) had PSG. Fifty-seven of 93 (61 %) children had OSA (median OAHI 4.5 events/h, range 1.1-24). PR-SD was not different between the OSA and non-OSA groups (p = 0.87). PRI tended to be higher in those with OSA, but there was considerable overlap between the groups: PRI-8 (mean ± SD 58.5 ± 29.0/h in OSA group vs 48.6 ± 20.2/h in non-OSA group, p = 0.07), PRI-10 (45.1 ± 25.0 vs 36.2 ± 16.7, p = 0.06) and PRI-15 (24.4 ± 14.5 vs 18.9 ± 9.0, p = 0.04). A PRI-15 threshold of >35/h had specificity of 97 % for OSA. The PRI-15 shows promise as an indicator of OSA in children with normal oximetry.

  13. The use of overnight pulse oximetry and phoniatrics parameters in the screening protocol of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Yassin Soliman Bahgat

    2012-10-01

    Conclusions: Polysomnography is the current golden standard test for diagnosis and evaluation of degree of OSA. Overnight pulse oximetry offers an inexpensive method of screening for and diagnosing OSAHS. Oximetry alone allowed confident recognition of moderate and severe cases of OSAHS. Acoustic analysis of snoring sounds and voice in patients with snoring and/or OSAHS is useful as a screening or supportive method with other investigations to diagnose the site of upper airway obstruction during sleep.

  14. Clinical evaluation of pulse oximetry monitors on critically ill patients.

    Science.gov (United States)

    De Pauw, C; Poelaert, J; Rolly, G; Colardyn, F

    1990-01-01

    Four pulse oximeters and two pulse oximeter-capnographs were evaluated on accuracy of measuring oxygen saturation and heartrate for the former and oxygen saturation, heartrate, respiratory rate and capnography for the latter. In the first part of the study four pulse oximeters (Criticare Systems Model 501 +, Ohmeda Biox 3700 Pulse Oximeter, Nellcor Model N 100 and Datex Satlite) were simultaneously studied on 10 ventilated ICU patients. Fifty simultaneous measurements were done for heartrate and oxygen saturation and compared to arterial saturations and ECG heartrates. Mean differences from pulse oximeter values versus control arterial and ECG values were within two percent for the four instruments. In the second part two oxicaps (Ohmeda 4700 and Nellcor N 1000) were evaluated with the same control parameters. Thirty measurements on 3 patients were done. As in the first part of the study all results were accurate within two percent of control values. From those data we can conclude that all examined monitors were fairly accurate compared to simultaneous arterial blood gas analysis and ECG monitoring. The oxicap monitors have the advantage of giving continuous information on two very important parameters of patient monitoring: CO2 and saturation.

  15. Detection of pulpal blood flow in vivo with pulse oximetry in dogs

    Directory of Open Access Journals (Sweden)

    Jessica eRiehl

    2016-05-01

    Full Text Available Objective: The aim of the present study was to investigate the ability of pulse oximetry to detect blood flow within the canine tooth of dogs. Materials and methods: Dogs aged 18-138 months presenting for oral treatment and meeting the inclusion criteria underwent pulse oximetry evaluation of at least one canine tooth. Oxygen saturation (SpO2 and pulse rate values were acquired from vital canine teeth of 38 clinical patients (representing 40 total teeth with a hand-held pulse oximeter and compared to a control area. SpO2 values from the tooth and control area were recorded every 5 seconds for three 60-second intervals. The sensors were repositioned after each 60-second interval. Results: The vital teeth consistently recorded SpO2 values significantly lower than the control area. The mean vital tooth SpO2 was 85.9% (median = 87%; SD = 8.6 and the mean control area SpO2 was 97.7% (median = 98%; SD = 1.8. An age-related significant difference was noted in vital tooth SpO2 values.Conclusions: In conclusion, the present data supports the possible use of pulse oximetry to detect blood flow in canine teeth. However, there was no significant correlation between SpO2 values in the vital tooth and in the control areas. Additionally, the results were not definitive and validation of the modality with additional studies of non-vital canine teeth is needed before clinical use can be recommended.

  16. Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

    Energy Technology Data Exchange (ETDEWEB)

    Hickey, M; Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom)

    2007-10-15

    Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO{sub 2}). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO{sub 2} in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO{sub 2} in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO{sub 2} in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO{sub 2}) in

  17. Continuous pulse oximetry in the general surgical ward: Nellcor N-200 versus Nellcor N-3000

    DEFF Research Database (Denmark)

    Christensen, M; Lie, C; Rosenberg, J

    1999-01-01

    New measurement principles in pulse oximetry have been introduced to decrease the incidence of false movement alarms. Experimental studies have shown that the new Nellcor Symphony N-3000 may reduce the incidence of false alarms when monitoring during different activities. We compared the Nellcor...... working principles of the two generations of oximeters were reflected in the present results derived from a clinical setting. The Nellcor Symphony N-3000 may offer an advantage compared with the Nellcor N-200, because of the reduced frequency of alarms and total time in alarm when monitoring patients...

  18. Domiciliary pulse-oximetry at exacerbation of chronic obstructive pulmonary disease: prospective pilot study

    Directory of Open Access Journals (Sweden)

    Goldring James JP

    2010-10-01

    Full Text Available Abstract Background The ability to objectively differentiate exacerbations of chronic obstructive pulmonary disease (COPD from day-to-day symptom variations would be an important development in clinical practice and research. We assessed the ability of domiciliary pulse oximetry to achieve this. Methods 40 patients with moderate-severe COPD collected daily data on changes in symptoms, heart-rate (HR, oxygen saturation (SpO2 and peak-expiratory flow (PEF over a total of 2705 days. 31 patients had data suitable for baseline analysis, and 13 patients experienced an exacerbation. Data were expressed as multiples of the standard deviation (SD observed from each patient when stable. Results In stable COPD, the SD for HR, SpO2 and PEF were approximately 5 min-1, 1% and 10l min-1. There were detectable changes in all three variables just prior to exacerbation onset, greatest 2-3 days following symptom onset. A composite Oximetry Score (mean magnitude of SpO2 fall and HR rise distinguished exacerbation onset from symptom variation (area under receiver-operating characteristic curve, AUC = 0.832, 95%CI 0.735-0.929, p = 0.003. In the presence of symptoms, a change in Score of ≥1 (average of ≥1SD change in both HR and SpO2 was 71% sensitive and 74% specific for exacerbation onset. Conclusion We have defined normal variation of pulse oximetry variables in a small sample of patients with COPD. A composite HR and SpO2 score distinguished exacerbation onset from symptom variation, potentially facilitating prompt therapy and providing validation of such events in clinical trials.

  19. The Feasibility and Validity of a Remote Pulse Oximetry System for Pulmonary Rehabilitation: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Jonathan Tang

    2012-01-01

    Full Text Available Pulmonary rehabilitation is an effective treatment for people with chronic obstructive pulmonary disease. However, access to these services is limited especially in rural and remote areas. Telerehabilitation has the potential to deliver pulmonary rehabilitation programs to these communities. The aim of this study was threefold: to establish the technical feasibility of transmitting real-time pulse oximetry data, determine the validity of remote measurements compared to conventional face-to-face measures, and evaluate the participants’ perception of the usability of the technology. Thirty-seven healthy individuals participated in a single remote pulmonary rehabilitation exercise session, conducted using the eHAB telerehabilitation system. Validity was assessed by comparing the participant's oxygen saturation and heart rate with the data set received at the therapist’s remote location. There was an 80% exact agreement between participant and therapist data sets. The mean absolute difference and Bland and Altman’s limits of agreement fell within the minimum clinically important difference for both oxygen saturation and heart rate values. Participants found the system easy to use and felt confident that they would be able to use it at home. Remote measurement of pulse oximetry data for a pulmonary rehabilitation exercise session was feasible and valid when compared to conventional face-to-face methods.

  20. Development and initial testing of a pulse oximetry prototype for measuring dental pulp vitality

    Science.gov (United States)

    Cerqueira, M.; Ferreira, M.; Caramelo, F.

    2015-05-01

    The guiding principle of endodontic treatment is to preserve teeth while maintaining its aesthetic and functional roles. To accomplish this goal the assessment of teeth pulp vitality is very important since it will determine the procedures that should be adopted and define the therapy strategy. Currently, the most commonly tests for determining dental pulp state are the thermal and the electrical tests, which are based on nerve response and, because of that, have a relatively high rate of false positives and false negatives cases. In this work we present a simple test to be used in the clinical setting for evaluating noninvasively the existence of blood perfusion in dental pulp. This test is based on pulse oximetry principle that was devised to indirectly measure the amount of oxygen in blood. Although pulse oximetry has already demonstrated its usefulness in clinical environment its usage for the determination of dental pulp vitality has been frustrated by several factors, notably the absence of a suitable sensor to the complex shape of the various coronary teeth. We developed a suitable sensor and present the first trials with promising results, regarding the ability for distinguish teeth with and without blood perfusion.

  1. Evaluation of oxygen saturation by pulse-oximetry in mouth breathing patients.

    Science.gov (United States)

    Niaki, Esfandiar Akhavan; Chalipa, Javad; Taghipoor, Elahe

    2010-01-01

    Mouth breathing might not always result in hypoxia, but can contribute to it. The aim of the present study was to determine the effect of mouth breathing on hypoxia. Based on a pilot study, 323 patients with mouth breathing were selected. Assessment of mouth breathing was based on clinical examination and questionnaires filled out by patients and their companions. The patients were also examined for further oral findings that could be attributable to mouth breathing. Oxygen saturation of each case was measured by means of a pulse oximetry device. The level of 95% saturation was set as the limit, under which the patient was considered hypoxemic. Acquired data was analyzed for descriptive data and frequency and also by means of the Chi-square and Spearman's correlation coefficient tests. 34.6% of the cases had normal O2 saturation. 65.4% of cases were hypoxemic (saturation level was below 95% in 42.8% and 95% in 22.6%). Most of the mouth breathing patients were male who were also more hypoxemic. A weak inverse relationship existed between the age of the patients and Oxygen saturation. Deep palatal vaults (29.4%) and gingival hyperplasia (29.2%) were the most frequent intraoral findings. Concerning the effects of hypoxia on body systems, the use of pulse oximetry in suspected mouth breathing patients could be recommended in routine oral and dental examinations.

  2. Evaluation of Oxygen Saturation by Pulse-Oximetry in Mouth Breathing Patients

    Directory of Open Access Journals (Sweden)

    Esfandiar Akhavan Niaki

    2010-02-01

    Full Text Available Mouth breathing might not always result in hypoxia, but can contribute to it. The aim of the present study was to determine the effect of mouth breathing on hypoxia. Based on a pilot study, 323 patients with mouth breathing were selected. Assessment of mouth breathing was based on clinical examination and questionnaires filled out by patients and their companions. The patients were also examined for further oral findings that could be attributable to mouth breathing. Oxygen saturation of each case was measured by means of a pulse oximetry device. The level of 95% saturation was set as the limit, under which the patient was considered hypoxemic. Acquired data was analyzed for descriptive data and frequency and also by means of the Chi-square and Spearman’s correlation coefficient tests.  34.6% of the cases had normal O2 saturation. 65.4% of cases were hypoxemic (saturation level was below 95% in 42.8% and 95% in 22.6%. Most of the mouth breathing patients were male who were also more hypoxemic.  A weak inverse relationship existed between the age of the patients and Oxygen saturation. Deep palatal vaults (29.4% and gingival hyperplasia (29.2% were the most frequent intraoral findings. Concerning the effects of hypoxia on body systems, the use of pulse oximetry in suspected mouth breathing patients could be recommended in routine oral and dental examinations.

  3. Combined heart rate variability and pulse oximetry biofeedback for chronic obstructive pulmonary disease: preliminary findings.

    Science.gov (United States)

    Giardino, Nicholas D; Chan, Leighton; Borson, Soo

    2004-06-01

    The purpose of this study was to examine the feasibility of an intervention that included heart rate variability (HRV) biofeedback and walking with pulse oximetry feedback to improve functioning and quality of life for patients with chronic obstructive pulmonary disease (COPD). Twenty patients with COPD participated in 5 weekly sessions of HRV biofeedback and 4 weekly sessions of walking practice with oximetry feedback, with instructions for daily home practice. Primary outcomes measures were the distance walked in 6 min (6MWD) and overall quality of life, as measured by the St. George's Respiratory Questionnaire (SGRQ). Secondary outcomes included measures of self-efficacy, self-reported disability, anxiety, depression, dyspnea before and after the 6MWD, and HRV at the frequency of respiration during spontaneous and paced breathing. After 10 weeks of training, participants showed statistically and clinically significant improvements in 6MWD and quality of life. Significant changes were also seen in self-efficacy, disability, dyspnea before and after the 6MWD, and HRV amplitude during spontaneous breathing. We conclude that our intervention is feasible for patients with COPD and that further research using a randomized controlled design is warranted.

  4. Pulse oximetry and supplemental oxygen during gastrointestinal endoscopy: a critical review

    DEFF Research Database (Denmark)

    Holm, C; Rosenberg, J

    1996-01-01

    A high proportion of the mortality and morbidity associated with endoscopic procedures may be of cardiopulmonary origin. For this reason, the appropriate degree of monitoring and prophylactic measures to be used in the sedated patient undergoing endoscopy has become a topic of discussion during...... recent years. The development of myocardial ischaemia during gastrointestinal endoscopy has traditionally been considered to be due to the simultaneous arterial hypoxaemia; however, recent investigations have suggested that tachycardia may be a more important pathogenic factor. No study has ever shown...... that pulse oximetry monitoring or supplemental oxygen will reduce the morbidity or mortality during gastrointestinal endoscopy. The current guidelines for monitoring and oxygen therapy are therefore not supported by scientific data. There is a need for further studies on the pathogenic mechanisms...

  5. Is Pulse Oximetry Useful for Screening Neonates for Critical Congenital Heart Disease at High Altitudes?

    Science.gov (United States)

    Hoffman, Julien I E

    2016-06-01

    Now that pulse oximetry is used widely to screen for critical congenital heart disease, it is time to consider whether this screening method is applicable to those who live at high altitudes. Consideration of basic physical principles and reports from the literature indicate that not only is the 95 % cutoff point for arterial oxygen saturation incorrect at high altitudes, but the lower saturations are accompanied by greater variability and therefore there is the possibility of a greater percentage of false-positive screening tests at high altitudes. Because of ethnic differences in response to high altitudes, normative data will have to be collected separately in different countries and perhaps for different ethnic groups.

  6. Diagnostic accuracy of a mathematical model to predict apnea-hypopnea index using nighttime pulse oximetry

    Science.gov (United States)

    Ebben, Matthew R.; Krieger, Ana C.

    2016-03-01

    The intent of this study is to develop a predictive model to convert an oxygen desaturation index (ODI) to an apnea-hypopnea index (AHI). This model will then be compared to actual AHI to determine its precision. One thousand four hundred and sixty-seven subjects given polysomnograms with concurrent pulse oximetry between April 14, 2010, and February 7, 2012, were divided into model development (n=733) and verification groups (n=734) in order to develop a predictive model of AHI using ODI. Quadratic regression was used for model development. The coefficient of determination (r2) between the actual AHI and the predicted AHI (PredAHI) was 0.80 (r=0.90), which was significant at a papnea.

  7. Pulse oximetry in the newborn: Is the left hand pre- or post-ductal?

    Directory of Open Access Journals (Sweden)

    Bucher Hans

    2010-05-01

    Full Text Available Abstract Background Over the past few years, great efforts have been made to screen duct-dependent congenital heart diseases in the newborn. Arterial pulse oximetry screening (foot and/or right hand has been put forth as the most useful strategy to prevent circulatory collapse. The left hand, however, has always been ignored, as it was unclear if the ductus arteriosus influences left-hand arterial perfusion. The objective of our study was to evaluate the impact of the arterial duct on neonatal pulse oximetry saturation (POS on the left hand. Methods In this observational study, arterial oxygen saturation on both hands and on one foot was measured within the first 4 hours of life. Results Two hundred fifty-one newborns were studied: 53% males and 47% were delivered by caesarean section. The median gestational age was 38 4/7 weeks (90% CI, 32 6/7 - 41 2/7 weeks, the median birth weight was 3140 g (90% CI, 1655 - 4110 g and the median age at recording was 60 minutes (90% CI, 15 - 210 minutes. The mean POS for the overall study population was 95.7% (90% CI, 90 - 100% on the right hand, 95.7% (90% CI, 90 - 100% on the left hand, and 94.9% (90% CI, 86 - 100% on the foot. Four subgroups (preterm infants, babies with respiratory disorders, neonates delivered by caesarean section, and newborns ≤15 minutes of age were formed and analysed separately. None of the subgroups showed a statistically significant difference between the right and left hands. Additionally, multivariate logistic regression did not identify any associated factors influencing the POS on the left hand. Conclusions With the exception of some children with complex or duct dependent congenital heart defects and some children with persistent pulmonary hypertension, POS on both hands can be considered equally pre-ductal.

  8. Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution

    Directory of Open Access Journals (Sweden)

    Zhang Yuan-ting

    2005-03-01

    Full Text Available Abstract Background The pulse oximeter, a medical device capable of measuring blood oxygen saturation (SpO2, has been shown to be a valuable device for monitoring patients in critical conditions. In order to incorporate the technique into a wearable device which can be used in ambulatory settings, the influence of motion artifacts on the estimated SpO2 must be reduced. This study investigates the use of the smoothed psuedo Wigner-Ville distribution (SPWVD for the reduction of motion artifacts affecting pulse oximetry. Methods The SPWVD approach is compared with two techniques currently used in this field, i.e. the weighted moving average (WMA and the fast Fourier transform (FFT approaches. SpO2 and pulse rate were estimated from a photoplethysmographic (PPG signal recorded when subject is in a resting position as well as in the act of performing four types of motions: horizontal and vertical movements of the hand, and bending and pressing motions of the finger. For each condition, 24 sets of PPG signals collected from 6 subjects, each of 30 seconds, were studied with reference to the PPG signal recorded simultaneously from the subject's other hand, which was stationary at all times. Results and Discussion The SPWVD approach shows significant improvement (p Conclusion The results suggested that the SPWVD approach could potentially be used to reduce motion artifact on wearable pulse oximeters.

  9. Pulmonary ultrasound and pulse oximetry versus chest radiography and arterial blood gas analysis for the diagnosis of acute respiratory distress syndrome: a pilot study

    OpenAIRE

    Bass, Cameron M.; Sajed, Dana R.; Adedipe, Adeyinka A.; West, T Eoin

    2015-01-01

    Introduction In low-resource settings it is not always possible to acquire the information required to diagnose acute respiratory distress syndrome (ARDS). Ultrasound and pulse oximetry, however, may be available in these settings. This study was designed to test whether pulmonary ultrasound and pulse oximetry could be used in place of traditional radiographic and oxygenation evaluation for ARDS. Methods This study was a prospective, single-center study in the ICU of Harborview Medical Center...

  10. Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

    Science.gov (United States)

    Niknafs, Pedram; Norouzi, Elahe; Bahman Bijari, Bahareh; Baneshi, Mohammad Reza

    2015-05-01

    Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia.

  11. Monitoring respiration in wheezy preschool children by pulse oximetry plethysmogram analysis.

    Science.gov (United States)

    Wertheim, David; Olden, Cathy; Symes, Liz; Rabe, Heike; Seddon, Paul

    2013-09-01

    The aim of this study was to investigate whether respiratory information can be derived from pulse oximetry plethysmogram (pleth) recordings in acutely wheezy preschool children. A digital pulse oximeter was connected via 'Bluetooth' to a notebook computer in order to acquire pleth data. Low pass filtering and frequency analysis were used to derive respiratory rate from the pleth trace; the ratio of heart rate to respiratory rate (HR/RR) was also calculated. Recordings were obtained during acute wheezy episodes in 18 children of median age 31 months and follow-up recordings from 16 of the children were obtained when they were wheeze-free. For the acutely wheezy children, frequency analysis of the pleth waveform was within 10 breaths/min of clinical assessment in 25 of 29 recordings in 15 children. For the follow-up measurements, frequency analysis of the pleth waveform showed similarly good agreement in recordings on 15 of the 16 children. Respiratory rate was higher (p < 0.001), and HR/RR ratio was lower (p = 0.03) during acute wheeze than at follow-up. This study suggests that respiratory rate can be derived from pleth traces in wheezy preschool children.

  12. Oxygen and pulse oximetry in childhood pneumonia: a survey of healthcare providers in resource-limited settings.

    Science.gov (United States)

    Ginsburg, Amy Sarah; Van Cleve, William C; Thompson, Mary I W; English, Mike

    2012-10-01

    Globally, pneumonia is the leading cause of death in children provider perceptions and practices regarding their role in childhood pneumonia, we conducted a survey using a convenience sampling strategy targeting clinicians working in resource-limited countries. Most respondents were physicians from public district and provincial hospitals with access to oxygen and pulse oximetry; however, reported therapeutic use for childhood pneumonia was low. Common barriers included insufficient supply, competition for use, lack of policies, guidelines and training and perceived high cost. Despite the frequency of hypoxemia, the inaccuracy of clinical predictors, the poor outcome hypoxemia portends and the effectiveness of pulse oximetry and oxygen in childhood pneumonia, our data indicate that these tools may be underused in resource-limited settings.

  13. Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block

    Directory of Open Access Journals (Sweden)

    Yamazaki H

    2012-03-01

    Full Text Available Hajime Yamazaki, Junichi Nishiyama, Toshiyasu SuzukiDepartment of Anesthesiology, Surgical Science, Tokai University School of Medicine, Kanagawa, JapanBackground: Stellate ganglion block (SGB is a widely used procedure for treatment of pain in the head and upper body, but the clinical signs used to verify the effectiveness of SGB can be ambiguous or variable in some patients. We observed the chronological changes in perfusion index (PI from pulse oximetry to determine if these changes correlated with the clinical signs associated with an effective SGB. We hypothesized that PI could provide an easy method to assess the effectiveness of SGB.Method: We compared the chronologies in PI on the treated and untreated sides of 21 patients in whom treatment by SGB was found to be effective. The SGB was performed by administering 6 mL of 1% mepivacaine. The effectiveness of the SGB was confirmed on the basis of clinical signs. Additionally, in two patients we tested whether increased PI on the treatment side correlated with increased microcirculation as measured by laser-Doppler blood flowmetry.Results: On the side treated by SGB, PI increased 61.4% in the earlobe and 60.5% from baseline values in the upper limbs, at 5 minutes after initiation of the procedure. Differences in PI before and after treatment were significant at both sites. No time-course increases in PI were found on the untreated side at either site. Following SGB, increases in PI correlated with increases in blood flow as measured by laser-Doppler flowmetry.Conclusion: PI increased in the earlobe and upper limbs on the treated side of 21 patients who received an effective SGB but not on the untreated side. The positive correlations between changes in PI and both presence of clinical signs and changes in blood flow in the skin microcirculation indicate a sympatholytic effect, suggesting that the PI could be useful in determination of the efficacy of SGB.Keywords: stellate ganglion block

  14. Examination of Pulse Oximetry Tracings to Detect Obstructive Sleep Apnea in Patients with Advanced Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Adrienne S Scott

    2014-01-01

    Full Text Available Nocturnal hypoxemia and obstructive sleep apnea (OSA are common comorbidities in patients with chronic obstructive pulmonary disease (COPD. The authors sought to develop a strategy to interpret nocturnal pulse oximetry and assess its capacity for detection of OSA in patients with stage 3 to stage 4 COPD. A review of consecutive patients with COPD who were clinically prescribed oximetry and polysomnography was conducted. OSA was diagnosed if the polysomnographic apnea-hypopnea index was >15 events/h. Comprehensive criteria were developed for interpretation of pulse oximetry tracings through iterative validation and interscorer concordance of ≥80%. Criteria consisted of visually identified desaturation ‘events’ (sustained desaturation ≥4%, 1 h time scale, ‘patterns’ (≥3 similar desaturation/saturation cycles, 15 min time scale and the automated oxygen desaturation index. The area under the curve (AUC, sensitivity, specificity and accuracy were calculated. Of 59 patients (27 male, 31 had OSA (53%. The mean forced expiratory volume in 1 s was 46% of predicted (range 21% to 74% of predicted and 52% of patients were on long-term oxygen therapy. Among 59 patients, 35 were correctly identified as having OSA or not having OSA, corresponding to an accuracy of 59%, with a sensitivity and specificity of 59% and 60%, respectively. The AUC was 0.57 (95% CI 0.55 to 0.59. Using software-computed desaturation events (hypoxemia ≥4% for ≥10 s indexed at ≥15 events/h of sleep as diagnostic criteria, sensitivity was 60%, specificity was 63% and the AUC was 0.64 (95%CI 0.62 to 0.66. No single criterion demonstrated important diagnostic utility. Pulse oximetry tracing interpretation had a modest diagnostic value in identifying OSA in patients with moderate to severe COPD.

  15. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

  16. Neural networks and wavelet analysis in the computer interpretation of pulse oximetry data

    Energy Technology Data Exchange (ETDEWEB)

    Dowla, F.U.; Skokowski, P.G.; Leach, R.R. Jr.

    1996-03-01

    Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. The sensor consists of red and infrared light sources and photodetectors. A method based on neural networks and wavelet analysis is developed for improved saturation estimation in the presence of sensor motion. Spectral and correlation functions of the dual channel oximetry data are used by a backpropagation neural network to characterize the type of motion. Amplitude ratios of red to infrared signals as a function of time scale are obtained from the multiresolution wavelet decomposition of the two-channel data. Motion class and amplitude ratios are then combined to obtain a short-time estimate of the oxygen saturation level. A final estimate of oxygen saturation is obtained by applying a 15 s smoothing filter on the short-time measurements based on 3.5 s windows sampled every 1.75 s. The design employs two backpropagation neural networks. The first neural network determines the motion characteristics and the second network determines the saturation estimate. Our approach utilizes waveform analysis in contrast to the standard algorithms that are based on the successful detection of peaks and troughs in the signal. The proposed algorithm is numerically efficient and has stable characteristics with a reduced false alarm rate with a small loss in detection. The method can be rapidly developed on a digital signal processing platform.

  17. Feasibility of pulse oximetry for assessment of infants born in community based midwifery care.

    Science.gov (United States)

    Smit, Marrit; Ganzeboom, Angelina; Dawson, Jennifer A; Walther, Frans J; Bustraan, Jacqueline; van Roosmalen, Jos J M; te Pas, Arjan B

    2014-05-01

    to evaluate the feasibility of using pulse oximetry (PO) for evaluating infants born in community-based midwifery care. a prospective, observational study of infants born after midwifery supervised (home) births. 27 midwives from seven practices providing primary care in (home) births used PO at birth or the early puerperal period over a ten-month period. Data were obtained on the effect of PO on outcome, interventions and decision-making. Midwives were surveyed about applicability and usefulness of PO. 153 infants born in primary midwifery care. all births were uncomplicated except for one infant receiving supplemental oxygen and another was mask ventilated. In 138/153 (90%) infants PO was successfully used and 88% of midwives found PO easy to use. In 148/153 (97%) infants PO did not influence midwives' clinical judgment and referral policy. In 5/153 (3%) infants, midwives were uncertain of the infant's condition, but PO measurements were reassuring. In case of suboptimal neonatal condition or resuscitation, 100% of midwives declared they would use PO again. it is feasible to use PO in community based midwifery care, but not considered an important contribution to routine evaluation of infants. Midwives would like to have PO available during suboptimal neonatal condition or when resuscitation is required. PO can be applied in community based midwifery care; it does not lead to insecurity or extra referral. Further research on a larger group of infants must show the effect of PO on neonatal outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Assessment of Arterial Oxygen Saturation by Pulse Oximetry Before, During and After Electroconvulsive Therapy

    Directory of Open Access Journals (Sweden)

    SH Tarig

    2006-07-01

    Full Text Available Introduction & Objective: Electroconvulsive therapy (ECT is used widely in psychiatric practice. The goal of anesthesia for ECT is the prevention of complications such as discomfort, fractures, aspiration of gastric contents and hypoxia. However, general anesthesia can cause some adverse effects as hypoxia. Prevention and treatment of hypoxia is important due to its undesirable effects on seizure duration and cardiovascular system. This study was designed to detect the incidence and probable times of desaturation in patients receiving ECT. Materials & Methods: This prospective randomized clinical trial was carried out on 100 patients (18-50 y/o with ASA I or II who were scheduled for ECT. After pre-oxygenation and similar anesthesia induction the patients received ECT. The patients were ventilated by oxygen and face masked until the return of their spontaneous respiration with adequate tidal volume and respiratory rate. Then they were transferred to recovery room where there was no oxygen supplementation. Oxygen saturation was measured by a Nell core pulse oximeter and was recorded at six stages: before and after anesthesia induction, during ECT, after ECT, 5 minutes after entering recovery room and before leaving there. The data were analyzed by standard statistical tests using SPSS software Results: Data analysis revealed that desaturation was not noticed at any stage except for the 5th stage (5 minutes after entering recovery room, when 13% of patients developed Sao2% less than 90%. Also there was a significant difference between Sao2% of patients between this stage (5th and other stages (p<0.001. Conclusion: According to our findings, appropriate oxygen supplementation and pulse oximetry monitoring during recovery period after ECT can be recommend

  19. Hepatopulmonary syndrome in patients with chronic liver disease: role of pulse oximetry

    Directory of Open Access Journals (Sweden)

    Olschewski Manfred

    2006-04-01

    Full Text Available Abstract Background Hepatopulmonary syndrome (HPS is a rare complication of liver diseases of different etiologies and may indicate a poor prognosis. Therefore, a simple non-invasive screening method to detect HPS would be highly desirable. In this study pulse oximetry was evaluated to identify patients with HPS. Methods In 316 consecutive patients with liver cirrhosis (n = 245, chronic hepatitis (n = 69 or non-cirrhotic portal hypertension (n = 2 arterial oxygen saturation (SaO2 was determined using a pulse oximeter. In patients with SaO2 ≤92% in supine position and/or a decrease of ≥4% after change from supine to upright position further diagnostic procedures were performed, including contrast-enhanced echocardiography and perfusion lung scan. Results Seventeen patients (5.4% had a pathological SaO2. Four patients (1.3% had HPS. HPS patients had a significant lower mean SaO2 in supine (89.7%, SD 5.4 vs. 96.0%, SD 2.3; p = 0.003 and upright position (84.3%, SD 5.0 vs. 96.0%, SD 2.4; p = 0.001 and had a lower mean PaO2 (56.2 mm Hg, SD 15.2 vs. 71.2 mm Hg, SD 20.2; p = 0.02 as compared to patients without HPS. The mean ΔSaO2 (difference between supine and upright position was 5.50 (SD 7 in HPS patients compared to non-HPS patients who showed no change (p = 0.001. There was a strong correlation between shunt volume and the SaO2 values (R = -0.94. Conclusion Arterial SaO2 determination in supine and upright position is a useful non-invasive screening test for HPS and correlates well with the intrapulmonary shunt volume.

  20. Estimating changes in Stroke Volume by non-invasive pulse-oximetry Pulse Transit Time Measurements

    NARCIS (Netherlands)

    ten Bokkel-Andela, J.; Poterman, Marieke; Scheeren, Thomas; Kalmar, A.F.

    2015-01-01

    Background and Goal of Study:  Pulse wave transit time (PTT), the interval between the R-wave peak on an electrocardiogram (ECG) and arrival of the pulse waves in the periphery (e.g. the finger), is reported to be a reliable estimate for stroke volume[1,2]. In this study, the PTT based on ECG and th

  1. Timing of Newborn Pulse Oximetry Screenings for Critical Congenital Heart Defects Before Discharge.

    Science.gov (United States)

    Crouch, Lynn; Speroni, Karen Gabel; Jones, Ruth Ann; MacDougall, Eileen P; Daniel, Marlon G

    2016-01-01

    To determine if there would be positive results from a second pulse oximetry screening (POS) completed for newborns at discharge at 28 to 48 hours of age in addition to the newborn POS completed at 24 to 25 hours of age. Prospective descriptive research study. Rural, mid-Atlantic, 13-bed, level I hospital. Newborns (N = 1,002) at 35 weeks' gestation or older discharged from the newborn nursery. Registered nurses (RNs) performed POS at 24 to 25 hours of age (POS 1) and at discharge but less than 48 hours of age (POS 2). Data related to critical congenital heart defects were collected. There were no positive POS results (O2 saturation ≤ 90%) at POS 1 or POS 2, and no additional diagnostic tests were ordered as a result of POS. Although one full-term newborn had negative results at POS 1 and POS 2, the RN identified a murmur, and a subsequent echocardiogram was used to detect tetralogy of Fallot and pulmonary atresia. The RNs detected concerning conditions in 14 newborns that resulted in 28 additional tests, including echocardiograms (9), chest x-ray imaging (8), laboratory testing (7), electrocardiograms (3), and ultrasound imaging (1). The POS-positive result rate was 0 for newborns at POS 1 and POS 2. Therefore, our study findings supported Maryland's mandate of one POS completed within 24 to 48 hours of birth. Nurses must continue to be vigilant about assessing newborns, including screening for critical congenital heart defects and congenital heart defects. Copyright © 2016 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses. Published by Elsevier Inc. All rights reserved.

  2. Canadian Cardiovascular Society/Canadian Pediatric Cardiology Association Position Statement on Pulse Oximetry Screening in Newborns to Enhance Detection of Critical Congenital Heart Disease.

    Science.gov (United States)

    Wong, Kenny K; Fournier, Anne; Fruitman, Deborah S; Graves, Lisa; Human, Derek G; Narvey, Michael; Russell, Jennifer L

    2017-02-01

    Congenital heart disease is the most common congenital malformation and approximately 3 in 1000 newborns have critical congenital heart disease (CCHD). Timely diagnosis affects morbidity, mortality, and disability, and newborn pulse oximetry screening has been studied to enhance detection of CCHD. In this position statement we present an evaluation of the literature for pulse oximetry screening. Current detection strategies including prenatal ultrasound examination and newborn physical examination are limited by low diagnostic sensitivity. Pulse oximetry screening is safe, noninvasive, easy to perform, and widely available with a high specificity (99.9%) and moderately high sensitivity (76.5%). When an abnormal saturation is obtained, the likelihood of having CCHD is 5.5 times greater than when a normal result is obtained. The use of pulse oximetry combined with current strategies has shown sensitivities of up to 92% for detecting CCHD. False positive results can be minimized by screening after 24 hours, and testing the right hand and either foot might further increase sensitivity. Newborns with abnormal screening results should undergo a comprehensive assessment and echocardiography performed if a cardiac cause cannot be excluded. Screening has been studied to be cost neutral to cost effective. We recommend that pulse oximetry screening should be routinely performed in all healthy newborns to enhance the detection of CCHD in Canada. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

    Directory of Open Access Journals (Sweden)

    Pedram Niknafs

    2015-05-01

    Full Text Available Neonates with respiratory distress syndrome (RDS, who are treated according to INSURE protocol; require arterial blood gas (ABG analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia.

  4. The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Lord Jason A

    2010-05-01

    Full Text Available Abstract Background Pulse oximetry is routinely used to continuously and noninvasively monitor arterial oxygen saturation (SaO2 in critically ill patients. Although pulse oximeter oxygen saturation (SpO2 has been studied in several patient populations, including the critically ill, its accuracy has never been studied in emergency department (ED patients with severe sepsis and septic shock. Sepsis results in characteristic microcirculatory derangements that could theoretically affect pulse oximeter accuracy. The purposes of the present study were twofold: 1 to determine the accuracy of pulse oximetry relative to SaO2 obtained from ABG in ED patients with severe sepsis and septic shock, and 2 to assess the impact of specific physiologic factors on this accuracy. Methods This analysis consisted of a retrospective cohort of 88 consecutive ED patients with severe sepsis who had a simultaneous arterial blood gas and an SpO2 value recorded. Adult ICU patients that were admitted from any Calgary Health Region adult ED with a pre-specified, sepsis-related admission diagnosis between October 1, 2005 and September 30, 2006, were identified. Accuracy (SpO2 - SaO2 was analyzed by the method of Bland and Altman. The effects of hypoxemia, acidosis, hyperlactatemia, anemia, and the use of vasoactive drugs on bias were determined. Results The cohort consisted of 88 subjects, with a mean age of 57 years (19 - 89. The mean difference (SpO2 - SaO2 was 2.75% and the standard deviation of the differences was 3.1%. Subgroup analysis demonstrated that hypoxemia (SaO2 2 was in the 90-93% range the SaO2 was Conclusions Pulse oximetry overestimates ABG-determined SaO2 by a mean of 2.75% in emergency department patients with severe sepsis and septic shock. This overestimation is exacerbated by the presence of hypoxemia. When SaO2 needs to be determined with a high degree of accuracy arterial blood gases are recommended.

  5. Beyond Critical Congenital Heart Disease: Newborn Screening Using Pulse Oximetry for Neonatal Sepsis and Respiratory Diseases in a Middle-Income Country.

    Science.gov (United States)

    Jawin, Vida; Ang, Hak-Lee; Omar, Asma; Thong, Meow-Keong

    2015-01-01

    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country. In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively. Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low

  6. Utility of the Pediatric Sleep Questionnaire and Pulse Oximetry as Screening Tools in Pediatric Patients with Suspected Obstructive Sleep Apnea Syndrome

    Directory of Open Access Journals (Sweden)

    Jose A. Peña-Zarza

    2012-01-01

    Full Text Available Objective. To assess the screening tools in snoring patients. Material and Methods. A retrospective review of data was conducted from children between 2 and 15 years old who were referred on suspicion of obstructive sleep apnea-hypopnea (OSAH between June 2008 and June 2011. We excluded patients with significant comorbidities. Pediatric Sleep Questionnaire (PSQ, physical exam (PE, and pulse-oximetry data were collected and correlated with the results of the nightly polygraph at home. Results. We selected 98 patients. The 22-item version of the PSQ had sensitivity of 96% and specificity of 36.8%. The overall value of the clinic predictor of OSAH (PSQ and PE together exhibited an increased specificity 57.6% with 94.6% of sensitivity. The nocturnal home oximetry method used alone was very specific, 92.1%, but had a lower sensitivity, 77.1%. The set of clinical assessment tools used together with pulse-oximetry screening provided excellent specificity 98.1% and a positive predictive value 94.1% globally. The performance of this screening tool is related with the severity of OSAH and accuracy is better in moderate and severe cases. Conclusion. The combination of clinical assessment and pulse-oximetry screening can provide a sufficient diagnostic approach for pediatric patients with suspected OSAH at least in moderate and severe cases.

  7. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography

    Science.gov (United States)

    Bergese, Sergio D.; Kelley, Scott D.; McIntyre, Robert; Uribe, Alberto A.; Sethi, Rakesh; Watson, James N.; Addison, Paul S.

    2017-01-01

    .78 [95% limits of agreement: –1.16; +1.90] breaths per minute; hospitalized patients: 0.07 ± 1.99 [95% limits of agreement: –3.84; +3.97] breaths per minute). The root mean square deviation was 1.35 breaths per minute (healthy volunteers: 0.81; hospitalized patients: 1.60). CONCLUSIONS: These data demonstrate the performance of the Medtronic Nellcor Respiration Rate Software in healthy subjects and patients hospitalized in a low-acuity care setting when compared with clinician-reviewed capnography. The observed performance of this technology suggests that it may be a useful adjunct to continuous pulse oximetry monitoring by providing continuous respiratory rate measurements. The potential patient safety benefit of using combined continuous pulse oximetry and respiratory rate monitoring warrants assessment. PMID:28099286

  8. The effect of nail polish and acrylic nails on pulse oximetry reading using the Lifebox oximeter in Nigeria.

    Science.gov (United States)

    Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O

    2013-12-01

    AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (ppolish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.

  9. Measuring arterial oxygenation in a high altitude field environment: comparing portable pulse oximetry with blood gas analysis.

    Science.gov (United States)

    Ross, Elliot M; Matteucci, Michael J; Shepherd, Matthew; Barker, Matthew; Orr, Lance

    2013-06-01

    High altitude environments present unique medical treatment challenges. Medical providers often use small portable pulse oximetry devices to help guide their clinical decision making. A significant body of high altitude research is based on the use of these devices to monitor hypoxia, yet there is a paucity of evidence that these devices are accurate in these environments. We studied whether these devices perform accurately and reliably under true mountain conditions. Healthy unacclimatized active-duty military volunteers participating in mountain warfare training at 2100 m (6900 feet) above sea level were evaluated with several different pulse oximetry devices while in a cold weather, high altitude field environment and then had arterial blood gases (ABG) drawn using an i-STAT for comparison. The pulse oximeter readings were compared with the gold standard ABG readings. A total of 49 individuals completed the study. There was no statistically significant difference between any of the devices and the gold standard of ABG. The best performing device was the PalmSAT (PS) 8000SM finger probe with a mean difference of 2.17% and SD of 2.56 (95% CI, 1.42% to 2.92%). In decreasing order of performance were the PS 8000AA finger probe (mean ± SD, 2.54% ± 2.68%; 95% CI, 1.76% to 3.32%), the PS 8000Q ear probe (2.47% ± 4.36%; 95% CI, 1.21% to 3.75%), the Nonin Onyx 9500 (3.29% ± 3.12%; 95% CI, 2.39% to 4.20%), and finally the PS 8000R forehead reflectance sensor (5.15% ± 2.97%; 95% CI, 4.28% to 6.01%). Based on the results of this study, results of the newer portable pulse oximeters appear to be closely correlated to that of the ABG measurements when tested in true mountain conditions. Copyright © 2013 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  10. Oxygen Saturation Reference Value by Percutaneous Pulse Oximetry in Asymptomatic Newborn Babies in Nigeria: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Obumneme Ezeanosike

    2016-08-01

    Full Text Available About 1/4 of all neonatal deaths in Nigeria are caused by birth asphyxia. Normal values of oxygen saturation vary according to regional altitudes. They are important for the screening of cyanotic congenital heart diseases and during newborn resuscitation. There is a dearth of such information in Nigeria. We determined reference values for oxygen saturation by pulse oximetry (SpO2 in asymptomatic newborns aged ≤7 days in Enugu at an altitude of 180 m. The study was cross-sectional. Neonates weighing ≥1500 g at birth were enrolled consecutively. Pre-and post-ductal oxygen saturation was measured using a Datex-Ohmeda Tuffsat® pulse oximeter with neonatal probes. Five hundred and fourteen babies comprising of 24 (4.4% preterm and 490 (95.3% term neonates were studied. The mean pre-ductal SpO2 of all babies was 96.1% ± 1.4% and higher than mean post-ductal SpO2 of 95.9% ± 1.4% (p = 0.022. The mean pre-ductal SpO2 were 96.1% ± 1.5% and 96.1% ± 1.3%, (p = 1.000 for males and females, respectively. The mean pre-ductal SpO2 values were higher than the mean post-ductal SpO2 for the corresponding post-natal ages.

  11. A comparison of pulse oximetry and cerebral oxygenation in children with severe sleep apnea-hypopnea syndrome: a pilot study.

    Science.gov (United States)

    Olmo Arroyo, Jorge; Khirani, Sonia; Amaddeo, Alessandro; Griffon, Lucie; De Sanctis, Livio; Pouard, Philippe; Fauroux, Brigitte

    2017-05-31

    Near infrared spectroscopy (NIRS) has been used to assess the impact of obstructive sleep apnea-hypopnea syndrome (OSAHS) on cerebral oxygenation. However, the relationship between the variations in the cerebral tissue oxygen saturation (ΔTOI) and pulse oximetry (ΔSpO2 ) has not been assessed in children with OSAHS. Consecutive clinically stable children with severe OSAHS [apnea-hypopnea index (AHI) >15 events h(-1) ] diagnosed during a night-time polygraphy with simultaneous recording of cerebral oxygenation with NIRS (NIRO-200NX, Hamamatsu Photonics KK) were included between September 2015 and June 2016. Maximal ΔSpO2 (SpO2 drop from the value preceding desaturation to nadir) and concomitant variations in transcutaneous carbon dioxide (ΔPtcCO2 ), maximal ΔTOI and maximal variations in cerebral oxygenated (O2 Hb) and deoxygenated (HHb) haemoglobin were reported. The relationships between ΔSpO2 , ΔPtcCO2 and ΔTOI, ΔO2 Hb and ΔHHb were investigated. The data from five children (three boys, aged 9.6 ± 6.7 years, AHI 16-91 events h(-1) ) were analysed. Strong correlations were found between ΔSpO2 and ΔTOI (r = 0.887, P < 0.001), but also with ΔO2 Hb and ΔHHb with a particular pattern in the youngest child with a dark skin pigmentation. Mean ΔSpO2 was 20 ± 17% and mean ΔTOI was 8 ± 7%. Maximal ΔSpO2 of approximately 70% were coupled with ΔTOI of no more than 35%. ΔPtcCO2 correlated only weakly with the cerebral oxygenation indexes. This pilot study shows a strong relationship between pulse oximetry and cerebral oxygenation in children with OSAHS, with lower changes in TOI compared to SpO2 . Future studies should address the clinical impact of respiratory events on cerebral oxygenation and its consequences. © 2017 European Sleep Research Society.

  12. A review of signal processing used in the implementation of the pulse oximetry photoplethysmographic fluid responsiveness parameter.

    Science.gov (United States)

    Addison, Paul S

    2014-12-01

    ΔPOP is a physiological parameter derived from the respiration-induced change in the pulse oximetry plethysmographic (POP) waveform or "pleth." It has been proposed as a proxy for pulse pressure variation used in the determination of the response to intravascular volume expansion in hypovolemic patients. Many studies have now reported on the parameter, and many research groups have constructed algorithms for its computation from the first principles where the implementation details have been described. This review focuses on the signal processing aspects of ΔPOP, as reported in the literature, and aims to provide a comprehensive summary of the wide-ranging algorithmic strategies that have been attempted in its computation. A search was conducted for articles concerning the use of ΔPOP as a fluid responsiveness parameter. In particular, articles concerning the correlation between ΔPOP and pulse pressure variation were targeted. Comments and replies to comments by the authors in which signal processing aspects were discussed were also included in the review. The parameter is first defined, and a history of the early work surrounding pleth-based fluid responsiveness parameters is presented. This is followed by an overview of the signal processing methods used in the reported studies, including details of exclusion criteria, manual filtering (preprocessing), gain change issues, acquisition details, selection of registration periods, averaging methods, physiological influences on the pleth, and comments by the investigators themselves. It is concluded that to develop a robust, fully automated ΔPOP algorithm for use in the clinical environment, more rigorous signal processing is required. Specifically, signals should be evaluated over significant periods of time, with emphasis on the quality and temporal relevance of the information.

  13. A Novel Ring Shaped Photodiode for Reflectance Pulse Oximetry in Wireless Applications

    DEFF Research Database (Denmark)

    Duun, Sune; Haahr, Rasmus Grønbek; Birkelund, Karen;

    2007-01-01

    We present a pulse oximeter for use in home-care applications in a sticking patch with integrated electronics. The core in the pulse oximeter is a large ring shaped backside silicon pn photodiode placed around a Ledtronics dual LED with wavelengths of 660 nm and 940 nm. The concentric photodiode...

  14. Pulse oximetry-derived pleth variability index can predict dexmedetomidine-induced changes in blood pressure in spontaneously breathing patients.

    Science.gov (United States)

    Sato, Makoto; Kunisawa, Takayuki; Kurosawa, Atsushi; Sasakawa, Tomoki

    2016-11-01

    Hypertension or hypotension in patients receiving continuous infusions of dexmedetomidine (DEX) is often due to changes in vascular resistance caused by α2 receptor stimulation. We investigated whether baseline perfusion index (PI) and pleth variability index (PVI), derived from pulse oximetry readings, could predict DEX-induced changes in the hemodynamic status in spontaneously breathing patients. Observational study. Operating room. Patients (American Society of Anesthesiologists performance status 1 or 2) scheduled to undergo lower extremity or abdominal procedures under regional anesthesia were approached. The PI and PVI were set as baseline upon arrival in theater and were then measured at 2.5-minute intervals. Upon attaining stable hemodynamic status under spontaneous breathing, intravenous administration of DEX was initiated at 6 μg kg(-1) h(-1) for 10minutes, followed by continuous infusion at 0.6 μg kg(-1) h(-1). Blood pressure, heart rate, PI, and PVI were measured. Hypertension was defined as an increase in systolic blood pressure (SBP) >15% and hypotension as a decrease in SBP PVI correlated with the degree of change in SBP. The maximum percentage increase as well as the maximum percentage of decrease in SBP from baseline correlated with baseline PI (r=0.418 [P=.005] and r=0.507 [PPVI (r=-0.658 [PPVI PVI >16 identified DEX-induced hypotension (sensitivity 83%, specificity 64%). PVI may predict DEX-induced changes in blood pressure in spontaneously breathing patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Validation of pulse oximetry for monitoring of hypoxaemic episodes in the late postoperative period

    DEFF Research Database (Denmark)

    Stausholm, K; Rosenberg-Adamsen, S; Edvardsen, L;

    1997-01-01

    We monitored 12 patients undergoing major abdominal surgery using a pulse oximeter (Nellcor N-200) and a transcutaneous oxygen tension monitor (TINA, Radiometer A/S) on the second or third night after operation. Of the shortest hypoxaemic episodes measured with the pulse oximeter (... duration), 78% also occurred in the transcutaneous oxygen tension measurement. Episodes of longer duration (> or = 1 min duration on the pulse oximeter) were, in 95% of cases, reflected in the transcutaneous oxygen tension measurement also. Thus postoperative episodic desaturations lasting > or = 1 min...

  16. Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device.

    Science.gov (United States)

    Høiseth, Lars Øivind; Hoff, Ingrid Elise; Hagen, Ove Andreas; Kirkebøen, Knut Arvid; Landsverk, Svein Aslak

    2016-06-01

    Respiratory variations in the photoplethysmographic waveform amplitude predict fluid responsiveness under certain conditions. Processing of the photoplethysmographic signal may vary between different devices, and may affect respiratory amplitude variations calculated by the standard formula. The aim of the present analysis was to explore agreement between respiratory amplitude variations calculated using photoplethysmographic waveforms available from two different pulse oximeters. Analysis of registrations before and after fluid loads performed before and after open-heart surgery (aortic valve replacement and/or coronary artery bypass grafting) with patients on controlled mechanical ventilation. Photoplethysmographic (Nellcor and Masimo pulse oximeters) and arterial pressure waveforms were recorded. Amplitude variations induced by ventilation were calculated and averaged over ten respiratory cycles. Agreements for absolute values are presented in scatterplots (with least median square regression through the origin, LMSO) and Bland-Altman plots. Agreement for trending presented in a four-quadrant plot. Agreement between respiratory photoplethysmographic amplitude variations from the two pulse oximeters was poor with LMSO ΔPOPNellc = 1.5 × ΔPOPMas and bias ± limits of agreement 7.4 ± 23 %. Concordance rate with a fluid load was 91 %. Agreement between respiratory variations in the photoplethysmographic waveform amplitude calculated from the available signals output by two different pulse oximeters was poor, both evaluated by LMSO and Bland-Altman plot. Respiratory amplitude variations from the available signals output by these two pulse oximeters are not interchangeable.

  17. Continuous pulse oximetry in the general surgical ward: Nellcor N-200 versus Nellcor N-3000

    DEFF Research Database (Denmark)

    Christensen, M; Lie, C; Rosenberg, J

    1999-01-01

    Symphony N-3000 with the Nellcor N-200 pulse oximeter, when monitoring patients in the general surgical ward. Twenty-two patients were monitored during unrestricted ward activities for a total of 275 h with a N-3000 and a N-200 pulse oximeter simultaneously. Data were analysed for lack of concordance...... between the two pulse oximeters with respect to frequency of registered hypoxaemic episodes and thus the amount of time spent in the alarm state. The median number of desaturation episodes with the N-200 was 18 (range 0-511) compared with four (range 0-476) with the N-3000 (p ... of drop-outs (loss of signal) was 13 (range 1-46) with the N-200 compared with nine (2-41) with the N-3000 (p = 0.06). The N-200 registered saturation values of 85% or below for 23% of the observation time compared with 6% of the observation time with the N-3000 pulse oximeter (p

  18. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry

    NARCIS (Netherlands)

    Nijland, R.; Jongsma, H.W.; Nijhuis, J.G.; Oeseburg, Berend; Zijlstra, Willem

    1995-01-01

    Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible

  19. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry

    NARCIS (Netherlands)

    Nijland, Rick; Jongsma, H.W.; Nijhuis, J.G.; Oeseburg, Berend; Zijlstra, Willem

    1995-01-01

    Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influen

  20. Respiratory rate and pulse oximetry derived information as predictors of hospital admission in young children in Bangladesh: a prospective observational study

    Science.gov (United States)

    Garde, Ainara; Zhou, Guohai; Raihana, Shahreen; Dunsmuir, Dustin; Karlen, Walter; Dekhordi, Parastoo; Huda, Tanvir; Arifeen, Shams El; Larson, Charles; Kissoon, Niranjan; Dumont, Guy A; Ansermino, J Mark

    2016-01-01

    Objective Hypoxaemia is a strong predictor of mortality in children. Early detection of deteriorating condition is vital to timely intervention. We hypothesise that measures of pulse oximetry dynamics may identify children requiring hospitalisation. Our aim was to develop a predictive tool using only objective data derived from pulse oximetry and observed respiratory rate to identify children at increased risk of hospital admission. Setting Tertiary-level hospital emergency department in Bangladesh. Participants Children under 5 years (n=3374) presenting at the facility (October 2012–April 2013) without documented chronic diseases were recruited. 1-minute segments of pulse oximetry (photoplethysmogram (PPG), blood oxygen saturation (SpO2) and heart rate (HR)) and respiratory rate were collected with a mobile app. Primary outcome The need for hospitalisation based on expert physician review and follow-up. Methods Pulse rate variability (PRV) using pulse peak intervals of the PPG signal and features extracted from the SpO2 signal, all derived from pulse oximetry recordings, were studied. A univariate age-adjusted logistic regression was applied to evaluate differences between admitted and non-admitted children. A multivariate logistic regression model was developed using a stepwise selection of predictors and was internally validated using bootstrapping. Results Children admitted to hospital showed significantly (p<0.01) decreased PRV and higher SpO2 variability compared to non-admitted children. The strongest predictors of hospitalisation were reduced PRV-power in the low frequency band (OR associated with a 0.01 unit increase, 0.93; 95% CI 0.89 to 0.98), greater time spent below an SpO2 of 98% and 94% (OR associated with 10 s increase, 1.4; 95% CI 1.3 to 1.4 and 1.5; 95% CI 1.4 to 1.6, respectively), high respiratory rate, high HR, low SpO2, young age and male sex. These variables provided a bootstrap-corrected AUC of the receiver operating characteristic

  1. Pulse oximetry recorded from the Phone Oximeter for detection of obstructive sleep apnea events with and without oxygen desaturation in children.

    Science.gov (United States)

    Garde, Ainara; Dehkordi, Parastoo; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2015-01-01

    Obstructive sleep apnea (OSA) disrupts normal ventilation during sleep and can lead to serious health problems in children if left untreated. Polysomnography, the gold standard for OSA diagnosis, is resource intensive and requires a specialized laboratory. Thus, we proposed to use the Phone Oximeter™, a portable device integrating pulse oximetry with a smartphone, to detect OSA events. As a proportion of OSA events occur without oxygen desaturation (defined as SpO2 decreases ≥ 3%), we suggest combining SpO2 and pulse rate variability (PRV) analysis to identify all OSA events and provide a more detailed sleep analysis. We recruited 160 children and recorded pulse oximetry consisting of SpO2 and plethysmography (PPG) using the Phone Oximeter™, alongside standard polysomnography. A sleep technician visually scored all OSA events with and without oxygen desaturation from polysomnography. We divided pulse oximetry signals into 1-min signal segments and extracted several features from SpO2 and PPG analysis in the time and frequency domain. Segments with OSA, especially the ones with oxygen desaturation, presented greater SpO2 variability and modulation reflected in the spectral domain than segments without OSA. Segments with OSA also showed higher heart rate and sympathetic activity through the PRV analysis relative to segments without OSA. PRV analysis was more sensitive than SpO2 analysis for identification of OSA events without oxygen desaturation. Combining SpO2 and PRV analysis enhanced OSA event detection through a multiple logistic regression model. The area under the ROC curve increased from 81% to 87%. Thus, the Phone Oximeter™ might be useful to monitor sleep and identify OSA events with and without oxygen desaturation at home.

  2. Cerebral oximetry in preterm infants

    DEFF Research Database (Denmark)

    Greisen, Gorm; Andresen, Bjørn; Plomgaard, Anne Mette

    2016-01-01

    Preterm birth constitutes a major cause of death before 5 years of age and it is a major cause of neurodevelopmental impairment across the world. Preterm infants are most unstable during the transition between fetal and newborn life during the first days of life and most brain damage occurs...... in this period. The brain of the preterm infant is accessible for tissue oximetry by near-infrared spectroscopy. Cerebral oximetry has the potential to improve the long-term outcome by helping to tailor the support of respiration and circulation to the individual infant's needs, but the evidence is still lacking...

  3. Utility of overnight pulse oximetry and heart rate variability analysis to screen for sleep-disordered breathing in chronic heart failure.

    Science.gov (United States)

    Ward, Neil R; Cowie, Martin R; Rosen, Stuart D; Roldao, Vitor; De Villa, Manuel; McDonagh, Theresa A; Simonds, Anita; Morrell, Mary J

    2012-11-01

    Sleep-disordered breathing (SDB) is under diagnosed in chronic heart failure (CHF). Screening with simple monitors may increase detection of SDB in a cardiology setting. This study aimed to evaluate the accuracy of heart rate variability analysis and overnight pulse oximetry for diagnosis of SDB in patients with CHF. 180 patients with CHF underwent simultaneous polysomnography, ambulatory electrocardiography and wrist-worn overnight pulse oximetry. SDB was defined as an apnoea-hypopnoea index ≥15/h. To identify SDB from the screening tests, the per cent very low frequency increment (%VLFI) component of heart rate variability was measured with a pre-specified cutoff ≥2.23%, and the 3% oxygen desaturation index was measured with a pre-specified cutoff >7.5 desaturations/h. 173 patients with CHF had adequate sleep study data; SDB occurred in 77 (45%) patients. Heart rate variability was measurable in 78 (45%) patients with area under the %VLFI receiver operating characteristic curve of 0.50. At the ≥2.23% cutoff, %VLFI sensitivity was 58% and specificity was 48%. The 3% oxygen desaturation index was measurable in 171 (99%) patients with area under the curve of 0.92. At the pre-specified cutoff of >7.5 desaturations/h, the 3% oxygen desaturation index had a sensitivity of 97%, specificity of 32%, negative likelihood ratio of 0.08 and positive likelihood ratio of 1.42. Diagnostic accuracy was increased using a cutoff of 12.5 desaturations/h, with sensitivity of 93% and specificity of 73%. The high sensitivity and low negative likelihood ratio of the 3% oxygen desaturation index indicates that pulse oximetry would be of use as a simple screening test to rule out SDB in patients with CHF in a cardiology setting. The %VLFI component of heart rate variability is not suitable for detection of SDB in CHF.

  4. A History of Mild Traumatic Brain Injury affects Peripheral Pulse Oximetry during Normobaric Hypoxia

    Directory of Open Access Journals (Sweden)

    Leonard Temme

    2016-09-01

    Full Text Available Introduction: Physiological and emotional stressors increase symptoms of concussion in recently injured individuals and both forms of stress induce symptoms in people recovering from mild traumatic brain injury (mTBI but who are asymptomatic when not stressed or are at rest. Methods: Healthy asymptomatic adults (25.0 ± 5.1 years with a history of mTBI (n = 36 and matched healthy controls (n = 36 with no mTBI history were exposed to three levels of normobaric hypoxic stress generated with the Reduced Oxygen Breathing Device (ROBD (Environics, Inc., Tollande, CT, which reduced the percent oxygen by mixing sea level air with nitrogen. The ROBD reduced the percent oxygen in the breathable air from the normal 21% to 15.5% O2, 14% O2, and 13% O2. Under these conditions: (a a standard pulse oximeter recorded peripheral oxygen saturation (SpO2 and pulse rate (beats per minute, and (b the FIT (PMI, Inc., Rockville, MD recorded saccadic velocity and pupillary response dynamics to a brief light flash. Results: For all three hypoxic stress conditions the mTBI group had significantly higher SpO2 during the final minute of exposure than did the controls F(2.17,151.8 = 5.29, p < .001, η2 = .852 and the rate of SpO2 change over time was significantly shallower for the mTBI than for the controls F(2.3,161.3 = 2.863, p < .001, η2 = .569, Greenhouse-Geisser corrected. Overall, mTBI had lower pulse rate but the difference was only significant for the 14% O2 condition. FIT oculomotor measures were not sensitive to group differences. When exposed to mild or moderate normobaric hypoxic stress (15% O2: (1 SpO2 differences emerged between the mTBI and matched healthy controls, (2 heart rate trended lower in the mTBI group, and (3 FIT measures were not sensitive to group differences. Conclusion: A relatively minor hypoxic challenge can reveal measurable differences in SpO2 and heart rate in otherwise asymptomatic individuals with a history of mTBI.

  5. Pulmonary ultrasound and pulse oximetry versus chest radiography and arterial blood gas analysis for the diagnosis of acute respiratory distress syndrome: a pilot study.

    Science.gov (United States)

    Bass, Cameron M; Sajed, Dana R; Adedipe, Adeyinka A; West, T Eoin

    2015-07-21

    In low-resource settings it is not always possible to acquire the information required to diagnose acute respiratory distress syndrome (ARDS). Ultrasound and pulse oximetry, however, may be available in these settings. This study was designed to test whether pulmonary ultrasound and pulse oximetry could be used in place of traditional radiographic and oxygenation evaluation for ARDS. This study was a prospective, single-center study in the ICU of Harborview Medical Center, a referral hospital in Seattle, Washington, USA. Bedside pulmonary ultrasound was performed on ICU patients receiving invasive mechanical ventilation. Pulse oximetric oxygen saturation (SpO2), partial pressure of oxygen (PaO2), fraction of inspired oxygen (FiO2), provider diagnoses, and chest radiograph closest to time of ultrasound were recorded or interpreted. One hundred and twenty three ultrasound assessments were performed on 77 consecutively enrolled patients with respiratory failure. Oxygenation and radiographic criteria for ARDS were met in 35 assessments. Where SpO2 ≤ 97%, the Spearman rank correlation coefficient between SpO2/FiO2 and PaO2/FiO2 was 0.83, p arterial blood gas testing and chest radiography are not readily available.

  6. [Evaluation of circulatory state using pulse oximeter: 2. Measurement of total hemoglobin employing pulse CO-oximetry (Masimo Radical-7)].

    Science.gov (United States)

    Miyoshi, Hiroshi; Sumikawa, Koji

    2009-07-01

    Development of pulse oximeter technology has made it possible to measure total hemoglobin noninvasively. The use of Radical-7 would improve patient care in emergency medicine and chronic internal medicine as well as perioperative medicine, and could reduce the burden of the patient.

  7. Correlation of Venous Blood Gas and Pulse Oximetry With Arterial Blood Gas in the Undifferentiated Critically Ill Patient.

    Science.gov (United States)

    Zeserson, Eli; Goodgame, Ben; Hess, J Daniel; Schultz, Kristine; Hoon, Cynthia; Lamb, Keith; Maheshwari, Vinay; Johnson, Steven; Papas, Mia; Reed, James; Breyer, Michael

    2016-06-09

    Blood gas analysis is often used to assess acid-base, ventilation, and oxygenation status in critically ill patients. Although arterial blood gas (ABG) analysis remains the gold standard, venous blood gas (VBG) analysis has been shown to correlate with ABG analysis and has been proposed as a safer less invasive alternative to ABG analysis. The purpose of this study was to evaluate the correlation of VBG analysis plus pulse oximetry (SpO2) with ABG analysis. We performed a prospective cohort study of patients in the emergency department (ED) and intensive care unit (ICU) at a single academic tertiary referral center. Patients were eligible for enrollment if the treating physician ordered an ABG. Statistical analysis of VBG, SpO2, and ABG data was done using paired t test, Pearson χ(2), and Pearson correlation. There were 156 patients enrolled, and 129 patients completed the study. Of the patients completing the study, 53 (41.1%) were in the ED, 41 (31.8%) were in the medical ICU, and 35 (27.1%) were in the surgical ICU. The mean difference for pH between VBG and ABG was 0.03 (95% confidence interval: 0.03-0.04) with a Pearson correlation of 0.94. The mean difference for pCO2 between VBG and ABG was 4.8 mm Hg (95% confidence interval: 3.7-6.0 mm Hg) with a Pearson correlation of 0.93. The SpO2 correlated well with PaO2 (the partial pressure of oxygen in arterial blood) as predicted by the standard oxygen-hemoglobin dissociation curve. In this population of undifferentiated critically ill patients, pH and pCO2 on VBG analysis correlated with pH and pCO2 on ABG analysis. The SpO2 correlated well with pO2 on ABG analysis. The combination of VBG analysis plus SpO2 provided accurate information on acid-base, ventilation, and oxygenation status for undifferentiated critically ill patients in the ED and ICU. © The Author(s) 2016.

  8. A PC-Based Pulse Oximetry Monitor for Four Patients%微机化多床位脉搏血氧饱和度监测仪

    Institute of Scientific and Technical Information of China (English)

    刘国忠; 李萍

    2001-01-01

    微机多床位脉搏血氧饱和度监测仪具有系统结构简单、灵活、存储容量大、功能强、性能价格比高等特点,且易实现多机通讯。介绍了监测仪的硬件系统组成原理及软件模块功能。%Pulse oximeters are used in many departments of a hospital. The pc-based pulse oximetry monitor for many patients has the features of simplicity, flexbility, large memory,powerful function, high ratio of performance to price, and it is easy to communicate with mul-timonitors. The principles of hardware system and the function of software block of the monitor are introduced too in this paper.

  9. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy La capnografía es superior a la pulsioximetría en la detección de depresión respiratoria durante las colonoscopias

    Directory of Open Access Journals (Sweden)

    G. Cacho

    2010-02-01

    Full Text Available Background: pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide. Objective: we aimed at prospectively examining the advantages of capnography over the standard pulse oximetry monitoring during sedated colonoscopies. Patients and methods:fifty patients undergoing colonoscopy were simultaneously monitored with pulse oximetry and capnography by using two different devices in each patient. Several sedation regimens were administered. Episodes of apnea or hypoventilation detected by capnography were compared with the occurrence of hypoxemia. Results: twenty-nine episodes of disordered respiration occurred in 16 patients (mean duration 54.4 seconds. Only 38% of apnea or hypoventilation episodes were detected by pulse oximetry. A mean delay of 38.6 seconds was observed in the events detected by pulse oximetry (two episodes of disturbed ventilation were simultaneously detected by capnography and pulse oximetry. Conclusions: apnea or hypoventilation commonly occurs during colonoscopy with sedation. Capnography is more reliable than pulse oximetry in early detection of respiratory depression in this setting.

  10. Arterial input function of an optical tracer for dynamic contrast enhanced imaging can be determined from pulse oximetry oxygen saturation measurements

    Science.gov (United States)

    Elliott, Jonathan T.; Wright, Eric A.; Tichauer, Kenneth M.; Diop, Mamadou; Morrison, Laura B.; Pogue, Brian W.; Lee, Ting-Yim; St. Lawrence, Keith

    2012-12-01

    In many cases, kinetic modeling requires that the arterial input function (AIF)—the time-dependent arterial concentration of a tracer—be characterized. A straightforward method to measure the AIF of red and near-infrared optical dyes (e.g., indocyanine green) using a pulse oximeter is presented. The method is motivated by the ubiquity of pulse oximeters used in both preclinical and clinical applications, as well as the gap in currently available technologies to measure AIFs in small animals. The method is based on quantifying the interference that is observed in the derived arterial oxygen saturation (SaO2) following a bolus injection of a light-absorbing dye. In other words, the change in SaO2 can be converted into dye concentration knowing the chromophore-specific extinction coefficients, the true arterial oxygen saturation, and total hemoglobin concentration. A simple error analysis was performed to highlight potential limitations of the approach, and a validation of the method was conducted in rabbits by comparing the pulse oximetry method with the AIF acquired using a pulse dye densitometer. Considering that determining the AIF is required for performing quantitative tracer kinetics, this method provides a flexible tool for measuring the arterial dye concentration that could be used in a variety of applications.

  11. Sustainability and long-term effectiveness of the WHO surgical safety checklist combined with pulse oximetry in a resource-limited setting: two-year update from Moldova.

    Science.gov (United States)

    Kim, Rebecca Y; Kwakye, Gifty; Kwok, Alvin C; Baltaga, Ruslan; Ciobanu, Gheorghe; Merry, Alan F; Funk, Luke M; Lipsitz, Stuart R; Gawande, Atul A; Berry, William R; Haynes, Alex B

    2015-05-01

    Little is known about the sustainability and long-term effect of surgical safety checklists when implemented in resource-limited settings. A previous study demonstrated the marked, short-term effect of a structured hospital-wide implementation of a surgical safety checklist in Moldova, a lower-middle-income country, as have studies in other low-resource settings. To assess the long-term reduction in perioperative harm following the introduction of a checklist-based surgical quality improvement program in a resource-limited setting and to understand the long-term effects of such programs. Twenty months after the initial implementation of a surgical safety checklist and the provision of pulse oximetry at a referral hospital in Moldova, a lower-middle-income, resource-limited country in Eastern Europe, we conducted a prospective study of perioperative care and outcomes of 637 consecutive patients undergoing noncardiac surgery (the long-term follow-up group), and we compared the findings with those from 2106 patients who underwent surgery shortly after implementation (the short-term follow-up group). Preintervention data were collected from March to July 2010. Data collection during the short-term follow-up period was performed from October 2010 to January 2011, beginning 1 month after the implementation of the launch period. Data collection during the long-term follow-up period took place from May 25 to July 6, 2012, beginning 20 months after the initial intervention. The primary end points of interest were surgical morbidity (ie, the complication rate), adherence to safety process measures, and frequency of hypoxemia. Between the short- and long-term follow-up groups, the complication rate decreased 30.7% (P = .03). Surgical site infections decreased 40.4% (P = .05). The mean (SD) rate of completion of the checklist items increased from 88% (14%) in the short-term follow-up group to 92% (11%) in the long-term follow-up group (P rate of hypoxemic events

  12. [Outcome measures in perinatal medicine--pO2 and SO2. With remarks on pulse oximetry].

    Science.gov (United States)

    Roemer, V M

    2005-10-01

    Due to the outstanding pioneer work of Ronald E. Myers (Bethesda, Maryland) using term rhesus monkey fetuses we know for sure that hypoxia is the leading cause for brain damage and death when exposure occurs perinatally. He defined threshold values for oxygen content and time variables leading to death or cerebral injury. Years later pulsoximetry was developed for measuring fetal oxygen saturation (%) continuously. In this context the obstetrician wants to know: 1) what is the diagnostic potential of pO(2) (mmHg), SO(2) (%) and oxygen content (vol%) in umbilical blood? and 2) using these data could we ascertain fetal pulsoximetry which in addition uses the factor time. In a sample of 7814 term fetuses, delivered in cephalic presentation by the vaginal route, actual blood gases and the variables of the fetal acid-base balance were determined in umbilical blood using equipments (BMS up to ABL 3) from RADIOMETER, Copenhagen. Measurements were done immediately post-partum by trained medical personal. Fetal oxygen saturation (%) for HbF was computed using the algorithm of Ruiz et al. Oxygen content (vol%) was determined according to Severinghaus using Hb values (g%) in each case. The median pO(2) in blood of the umbilical artery (UA) was 17.9 (mean: 18.8 +/- 8.3) mm Hg and in the umbilical vein (UV) 28.5 (mean: 29.3 +/- 9.2) mmHg, respectively. The median oxygen saturation (%) amounted to 24.8 (UA) and 60.9 (UV) using pO(2), pH and pCO(2) for computation in each case. The oxygen variable pO(2) showed no clinically important correlation neither with actual pH (r = 0.032, P = 0.005) nor with base excess (r = 0.047, P values of 6.9 are associated with 10 % oxygen saturation only in UA. P (50) values change dramatically with lowering pH values, i. e., acidosis. Oxygen content (vol %) offers no diagnostic advantages over oxygen saturation. Separation of the whole sample (N = 7814) according to the boundary of 30 % saturation in UA/UV blood leads necessarily to a big

  13. Continuous non-invasive measurement of total hemoglobin concentration during major liver resection by pulse co-oximetry

    NARCIS (Netherlands)

    Vos, Jaap Jan; Scheeren, Thomas; Struys, Michel; Hendriks, H.G.D.

    2011-01-01

    Background and Goal of Study: The Masimo Radical 7 (V7.6.0.1, Masimo Corp, Irvine, USA) pulse co-oximeter® uses multi-wave length spectrophotometric analysis (sensor R2-25) to calculate total hemoglobin concentration (SpHb). SpHb is monitored continuously and non-invasively, which may reveal advanta

  14. A Ring-shaped photodiode designed for use in a reflectance pulse oximetry sensor in wireless health monitoring applications

    DEFF Research Database (Denmark)

    Duun, Sune; Haahr, Rasmus Grønbek; Birkelund, Karen

    2010-01-01

    We report a photodiode for use in a reflectance pulse oximeter for use in autonomous and low-power homecare applications. The novelty of the reflectance pulse oximeter is a large ring shaped backside silicon pn photodiode. The ring-shaped photodiode gives optimal gathering of light and thereby en...... is demonstrated to work in a laboratory setup with a Ledtronics dual LED with wavelengths of 660 and 940 nm. Using this setup photoplethysmograms which clearly show the cardiovascular cycle have been recorded. The sensor is shown to work very well with low currents of less than 10 mA....... a radius of 3.68 mm and a width of 0.78 mm giving an area of 18 mm2. The capacitance of the photodiode is measured to 34.5 nF. The quantum efficiency of the photodiode is measured to 55% and 62% at 660 nm and 940 nm, respectively. It is acceptable for this prototype but can be improved. The sensor also has...

  15. New hybrid reflectance optical pulse oximetry sensor for lower oxygen saturation measurement and for broader clinical application

    Science.gov (United States)

    Nogawa, Masamichi; Ching, Chong Thong; Ida, Takeyuki; Itakura, Keiko; Takatani, Setsuo

    1997-06-01

    A new reflectance pulse oximeter sensor for lower arterial oxygen saturation (Sa)2) measurement has been designed and evaluated in animals prior to clinical trials. The new sensor incorporates ten light emitting diode chips for each wavelength of 730 and 880 nm mounted symmetrically and at the radial separation distance of 7 mm around a photodiode chip. The separation distance of 7 mm was chosen to maximize the ratio of the pulsatile to the average plethysmographic signal level at each wavelength. The 730 and 880 wavelength combination was determined to obtain a linear relationship between the reflectance ratio of the 730 and 880 nm wavelengths and Sa)2. In addition to these features of the sensor, the Fast Fourier Transform method was employed to compute the pulsatile and average signal level at each wavelength. The performance of the new reflectance pulse oximeter sensor was evaluated in dogs in comparison to the 665/910 nm sensor. As predicted by the theoretical simulation based on a 3D photon diffusion theory, the 730/880 nm sensor demonstrated an excellent linearity over the SaO2 range from 100 to 30 percent. For the SaO2 range between 100 and 70 percent, the 665/910 and 730/880 sensors showed the standard error of around 3.5 percent and 2.1 percent, respectively, in comparison to the blood samples. For the range between 70 and 30 percent, the standard error of the 730/880 nm sensor was only 2.7 percent, while that of the 665/910 nm sensor was 9.5 percent. The 730/880 sensor showed improved accuracy for a wide range of SaO2 particularly over the range between 70 and 30 percent. This new reflectance sensor can provide noninvasive measurement of SaO2 accurately over the wide saturation range from 100 to 30 percent.

  16. 基于扩散理论的脉搏血氧测量系统%A Pulse Oximetry System Based on Diffusion Theory

    Institute of Scientific and Technical Information of China (English)

    高峰; 陈玮婷; 周晓青; 刘明; 张书颖; 赵会娟

    2013-01-01

    为了对低血氧饱和度进行准确测量,采用光子扩散方程模型替代传统的朗伯-比尔定律模型来推导血氧饱和度与特征值R之间的关系,并得到相应的定标曲线,从而克服了朗伯-比尔定律模型所固有的忽略散射效应这一问题及其所导致的较低的测量精度;在此基础上搭建了以数字信号处理器为核心处理设备的脉博血氧测量系统,并进行了手指阻断定性实验和低血氧饱和度水平下的仿体定量实验.实验结果表明,基于光子扩散方程模型的测量系统能够有效地反映出组织体血氧饱和度值的变化趋势;在低血氧饱和度情况下,采用扩散方程模型求得的结果较传统的朗伯-比尔定律模型获得的结果准确性提高了20%以上.该方法有望应用于低血氧饱和度的准确测量.%In order to overcome the inherent drawbacks of Lambert-Beer's Law, which ignores the scattering effect and thus leads to a poor measurement precision, especially for low oxygen saturation, a study on the accurate measurement of low oxygen saturation was conducted in this paper. The photon diffusion theory was employed to achieve the calibration curve between oxygen saturation and the eigenvalue R rather than Lambert-Beer's Law. A pulse oximetry system using digital signal processer as core device was set up based on the above theory. A finger blocking-up qualitative experiment and a series of quantitative phantom experiments were performed under low oxygen saturation. The results demonstrate that the measurement system based on photon diffusion theory can effectively provide the variation trends of oxygen saturation in tissue, and that there is an improvement of 20% in accuracy compared with Lambert-Beer's Law theory when low oxygen saturation is measured. The approach proposed in this paper offers a promising tool for the accurate measurement of low oxygen saturation.

  17. Oximetry in obese children with sleep-disordered breathing

    OpenAIRE

    Evangelisti, Melania; Shafiek, Hanaa; Rabasco, Jole; Forlani, Martina; Montesano, Marilisa; Barreto, Mario; Verhulst, Stijn; Villa, Maria Pia

    2016-01-01

    Abstract: Background: Obesity is an important risk factor for obstructive sleep apnea syndrome (OSAS), and obese children with OSAS have frequently shown oxygen desaturations when compared with normal-weight children. The aim of our study was to investigate the oximetry characteristics in children with obesity and sleep-disordered breathing (SDB). Methods: Children referred for suspected OSAS were enrolled in the study. All children underwent sleep clinical record (SCR), pulse oximetry, and p...

  18. 脉搏碳氧-血氧仪监测肝硬化患者血红蛋白浓度的精确性%Measurement of total hemoglobin in cirrhosis patients by pulse CO-Oximetry

    Institute of Scientific and Technical Information of China (English)

    张月宁; 单晶; 范春蕾; 董桂芳; 刘静

    2016-01-01

    Objective To evaluate the application of noninvasive pulse CO-Oximetry in continuous measurement of hemoglobin (Hb) in cirrhosis patients. Methods The level of hemoglobin was continuously measured using pulse CO-Oximetry, while samples of venous blood were collected to undergo routine testing. Results A total of 273 patients were enrolled in the current study. According to laboratory results, the concentration of Hb was between 33.6-129.8 g/L, with a mean value of (75.1 ± 4.9) g/L, in contrast with the readings between 42.3-140.8 g/L provided by pulse CO-Oximetry, with a mean value of (81.4±9.6) g/L (P<0.05). The regression equation of these two methods was y=1.56+0.857x, r=0.816, P=0.000. Bland-Altman analysis showed that the mean value of D-value between those two methods was 12.1g/L (95%CI 16-25 g/L), the mean value of M-value was 78.3 g/L and the ratio of D-value to M-value was 15.5%. Conclusions Masimo Radical-7 pulse CO-Oximetry tends to provide a higher reading than laboratory results. However, its readings show acceptable precision and accuracy and can reflect the trend of changes in hemoglobin level. With respect to its characteristics of non-incision and continuity, this method is worthy of promotion in clinical setting.%目的:评价无创脉搏碳氧-血氧仪连续监测肝硬化患者血红蛋白浓度的精确性。方法住院肝硬化患者用脉搏碳氧-血氧仪连续监测血红蛋白浓度,同时送静脉血至实验室进行血常规检测。结果共检测273例肝硬化患者,实验室测得血红蛋白浓度在33.6~129.8 g/L,均值(75.1±4.9)g/L;仪器检测血红蛋白在42.3~140.8 g/L,均值(81.4±9.6)g/L,P<0.05。两种检测结果的回归方程为y=1.56+0.957x,相关系数r=0.816,P=0.000。Bland-Altman一致性分析,两种检测方法差值的平均值为12.1g/L(95%CI为16~25 g/L),均值的平均值为78.3 g/L,差值占均值比为15.5%。结论Masimo Radical-7脉搏碳氧-血氧仪对于

  19. Jugular venous oximetry

    Directory of Open Access Journals (Sweden)

    Avanish Bhardwaj

    2015-01-01

    Full Text Available The measurement of saturation of venous blood as it drains out of brain by sampling it from the jugular bulb provides us with an estimate of cerebral oxygenation, cerebral blood flow and cerebral metabolic requirement. Arterio-jugular venous difference of the oxygen content (AVDO 2 and jugular venous oxygen saturation (SjVO 2 values per se helps clinicians in identifying the impairment of cerebral oxygenation due to various factors thereby prompting implementation of corrective measures and the prevention of secondary injury to the brain due to ischaemia. SjVO 2 values are also used for prognostication of patients after traumatic brain injury and in other clinical situations. Sampling and measuring SjVO 2 intermittently or continuously using fibreoptic oximetry requires the tip of the catheter to be placed in the jugular bulb, which is a relatively simple bedside procedure. In the review below we have discussed the relevant anatomy, physiology, techniques, clinical applications and pitfalls of performing jugular venous oximetry as a tool for measurement of cerebral oxygenation.

  20. Stairs climbing test with pulse oximetry as predictor of early postoperative complications in functionally impaired patients with lung cancer and elective lung surgery: prospective trial of consecutive series of patients.

    Science.gov (United States)

    Nikolić, Igor; Majerić-Kogler, Visnja; Plavec, Davor; Maloca, Ivana; Slobodnjak, Zoran

    2008-02-01

    To test the predictive value of stairs climbing test for the development of postoperative complications in lung cancer patients with forced expiratory volume in one second (FEV1)stairs climbing with pulse oximetry before the operation with the number of steps climbed and the time to complete the test recorded. Oxygen saturation and pulse rate were measured every 20 steps. Data on postoperative complications including oxygen use, prolonged mechanical ventilation, and early postoperative mortality were collected. Eighty-seven of 101 patients (86%) had at least one postoperative complication. The type of surgery was significantly associated with postoperative complications (25.5% patients with lobectomy had no early postoperative complications), while age, gender, smoking status, postoperative oxygenation, and artificial ventilation were not. There were more postoperative complications in more extensive and serious types of surgery (Pstairs climbing test produced a significant decrease in oxygen saturation (-1%) and increase in pulse rate (by 10/min) for every 20 steps climbed. The stairs climbing test was predictive for postoperative complications only in lobectomy group, with the best predictive parameter being the quotient of oxygen saturation after 40 steps and test duration (positive likelihood ratio [LR], 2.4; 95% confidence interval [CI], 1.71-3.38; negative LR, 0.53; 95% CI, 0.38-0.76). In patients with other types of surgery the only significant predictive parameter for incident severe postoperative complications was the number of days on artificial ventilation (P=0.006). Stairs climbing test should be done in routine clinical practice as a standard test for risk assessment and prediction of the development of postoperative complications in lung cancer patients selected for elective surgery (lobectomy). Comparative to spirometry, it detects serious disorders in oxygen transport that are a baseline for a later development of cardiopulmonary postoperative

  1. Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?

    Directory of Open Access Journals (Sweden)

    Carlos A. Nigro

    2011-01-01

    Full Text Available Objective. To assess the diagnostic ability of WristOx 3100 using its three different recording settings in patients with suspected obstructive sleep apnea syndrome (OSAS. Methods. All participants (135 performed the oximetry (three oximeters WristOx 3100 and polysomnography (PSG simultaneously in the sleep laboratory. Both recordings were interpreted blindly. Each oximeter was set to one of three different recording settings (memory capabilities 0.25, 0.5, and 1 Hz. The software (nVision 5.1 calculated the adjusted O2 desaturation index-mean number of O2 desaturation per hour of analyzed recording ≥2, 3, and 4% (ADI2, 3, and 4. The ADI2, 3, and 4 cutoff points that better discriminated between subjects with or without OSAS arose from the receiver-operator characteristics (ROCs curve analysis. OSAS was defined as a respiratory disturbance index (RDI ≥ 5. Results. 101 patients were included (77 men, mean age 52, median RDI 22.6, median BMI 27.4 kg/m2. The area under the ROCs curves (AUC-ROCs of ADI2, 3, and 4 with different data storage rates were similar (AUC-ROCs with data storage rates of 0.25/0.5/1 Hz: ADI2: 0.958/0.948/0.965, ADI3: 0.961/0.95/0.966, and ADI4: 0.957/0.949/0.963, P NS. Conclusions. The ability of WristOx 3100 to detect patients with OSAS was not affected by the data storage rate of the oxygen saturation signal. Both memory capacity of 0.25, 0.5, or 1 Hz showed a similar performance for the diagnosis of OSAS.

  2. Wearable Oximetry for Harsh Environments

    Science.gov (United States)

    2017-04-26

    to this, commercial oximetry sensors (e.g., from Masimo, BSX Insight, Cercacor) are now being marketed for enhancing performance of elite athletes...considerable re-packaging and integration. The green wavelength is well known to provide a strong modulation for measuring HR [8], as evidenced by nearly...every consumer PPG-based HR monitor using green LEDs. However, for oximetry, red and IR wavelengths are the standard choices, in order to

  3. Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery

    NARCIS (Netherlands)

    Vos, J. J.; Kalmar, A. F.; Struys, M. M. R. F.; Porte, R. J.; Wietasch, J. K. G.; Scheeren, T. W. L.; Hendriks, H. G. D.

    2012-01-01

    Background: The Masimo Radical 7 (Masimo Corp., Irvine, CA, USA) pulse co-oximeter calculates haemoglobin concentration (SpHb) non-invasively using transcutaneous spectrophotometry. We compared SpHb with invasive satellite-lab haemoglobin monitoring (Hb(satlab)) during major hepatic resections both

  4. Design of an Anti-Noise Wearable Pulse Oximetry%一种抗干扰穿戴式血氧饱和度监测仪的研制

    Institute of Scientific and Technical Information of China (English)

    龚渝顺; 吴宝明; 高丹丹; 闫庆广; 冯正权

    2012-01-01

    为实现动态环境下人体血氧饱和度的实时监测,研制了一种穿戴式血氧监测仪.采用D/A数模转换控制LED双光源交替发光,以光频转换接收头作为传感器,将光强信号转换为频率信号,直接送入单片机采集;根据反射式原理计算得到结果,通过无线方式发送数据.针对动态环境下获取的光电容积脉搏波中掺杂的运动干扰,提出了血氧干扰分离自适应对消算法,以消除运动干扰对计算结果的影响.设计实现了设备的小型化,提高了其可穿戴性,具有抗运动干扰的能力,能准确的获取血氧信息,适合在日常动态环境下的实时监测.%A wearable pulse oximetry was designed for real time measuring of oxygen saturation in motion condition. Digital-to-Analog converter was used to control LED which gives out light of different color alternately. The light reflected from body was collected by Optical-to-Frequency converter whose output was sent to MCU directly, and then the calculation result was transmitted wirelessly. An algorithm aiming at removing motion artifact mixed in PPG signal was designed to get accurate result. This device is suitable for real time monitoring in daily motion condition for its miniature design and anti-motion artifact ability.

  5. Spectrophotometric retinal oximetry in pigs

    DEFF Research Database (Denmark)

    Traustason, Sindri; Kiilgaard, Jens Folke; Karlsson, Robert

    2013-01-01

    PURPOSE: To assess the validity of spectrophotometric retinal oximetry, by comparison to blood gas analysis and intra-vitreal measurements of partial pressure of oxygen (pO2). METHODS: Female domestic pigs were used for all experiments (n=8). Oxygen fraction in inspired air was changed using...... a mixture of room air, pure oxygen and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry was performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1 (Oxymap ehf......, Reykjavik, Iceland). The device simultaneously acquires images at two wavelengths (570 nm and 600 nm) and specialized software automatically detects retinal blood vessels. In three pigs, invasive pO2-measurements were performed after the initial non-invasive measurements. RESULTS: Comparison of femoral...

  6. Design and Implementation of photoelectric pulse oximetry%光电脉搏血氧仪的设计与实现

    Institute of Scientific and Technical Information of China (English)

    刘俊微; 庞春颖; 徐伯鸾

    2014-01-01

    血氧饱和度作为供氧状态的一个重要指标,是医护人员对疾病进行预防、诊治的重要依据之一。针对当前脉搏血氧仪功耗大、稳定性差、成本与仪器精度不可兼得等缺陷,设计中给出了一种性价比高、低功耗、可进行无线传输的光电脉搏血氧仪设计方案。系统采用指夹式光电血氧探头对血氧信号进行采集,以S TM32芯片为控制核心,对采集到的信号进行分析、处理与结果显示,实现了对血氧饱和度便携、实时、连续的检测。最终设计通过使用Fluke公司生产的Index2型血氧模拟仪进行多次测试,结果表明当血氧饱和度处于60%~80%时精度为2%,80%~99%时精度为1%,脉率检测误差为±1 bpm,达到了医疗仪器的标准要求,使得本设计具有较好的使用价值。%Oxygen saturation as an important indicator of the state of oxygen is a significant basis to the health care workers on disease prevention,diagnosis and treatment.Due to the defects of the current pulse oximeter such as power consumption,poor stability,the balance between price and instrument accuracy,a cost-effective,low-power and wire-less transmission photoelectric pulse oximeter is designed.The system used oximeter finger clip to acquire the oxygen signal and took the STM32 chip as its CPU,then the collected signal is analyzed,processed and displayed on the screen,the detection of blood oxygen saturation portable real-time continuous is realized.After repeating the experi-ment under different conditions by Fluck Index2 oximeter simulator,the extensive experimental results demonstrate that the accuracy is 2%when oxygen saturation is between 60%to 80%and the accuracy is 1%when oxygen satura-tion is between 80%to 99%,the pulse rate error is less than 1 bpm.The results show that the design has reached the standard requirements for medical equipment,which makes the design has good value in use.

  7. Wearable oximetry for harsh environments

    Science.gov (United States)

    2017-02-23

    a wearable monitor is required. Related to this, commercial oximetry sensors (e.g., from Masimo, BSX Insight, Cercacor) are now being marketed for...Schmid, C. Fulco, S. Muza, “Predictive models of acute mountain sickness after rapid ascent to various altitudes,” Med & Sci in Sports & Exercise, 792

  8. Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients.

    Science.gov (United States)

    Baulig, Werner; Seifert, Burkhardt; Spahn, Donat R; Theusinger, Oliver M

    2017-02-01

    The Masimo Radical-7 Pulse CO-Oximeter (Masimo Corp., USA) non-invasively computes hemoglobin concentration (SpHb). SpHb was compared to Co-Oximeter readings (CoOxHb) of arterial samples in surgery patients of the emergency department. Forty-six patients were enrolled. The Masimo R1 25L (revision F and G) adult adhesive sensor was attached to the ring finger of the arterially cannulated hand. Before start, every 30 min during surgery and in the case of severe bleeding SpHb and CoOxHb values were documented. SpHb and post hoc adjusted SpHb (AdSpHb) values were analyzed. Linear regression analysis and Bland-Altman plot for agreement were performed. The detection failure rate of SpHb was 24.5 %. CoOxHb and SpHb showed a strong correlation (r = +0.81), but agreement was moderate [bias (LOA) of -0.6 (-3.0; +1.9)] g/dl. Positive and negative predicted value was 0.49 and 0.69. Exclusion of changes of CoOxHb values ≤1 g/dl resulted in a positive and negative predictive value of 0.66 and 1.00. Post hoc adjustment of the SpHb (AdSpHb) improved linear correlation of CoOxHb and AdSpHb [r = +0.90 (p values and predicted decreases of CoOxHb only if changes of SpHb ≤ 1.0 g/dl were excluded. The detection failure rate of SpHb was high. At present, additional refinements of the current technology are necessary to further improve performance of non-invasive hemoglobin measurement in the clinical setting.

  9. Increased blood glycohemoglobin A1c levels lead to overestimation of arterial oxygen saturation by pulse oximetry in patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Pu Li

    2012-09-01

    Full Text Available Abstract Background Non-enzymatic glycation increases hemoglobin-oxygen affinity and reduces oxygen delivery to tissues by altering the structure and function of hemoglobin. Objectives We investigated whether an elevated blood concentration of glycosylated hemoglobin (HbA1c could induce falsely high pulse oximeter oxygen saturation (SpO2 in type 2 diabetic patients during mechanical ventilation or oxygen therapy. Methods Arterial oxygen saturation (SaO2 and partial pressure of oxygen (PO2 were determined with simultaneous monitoring of SpO2 in 261 type 2 diabetic patients during ventilation or oxygen inhalation. Results Blood concentration of HbA1c was >7% in 114 patients and ≤ 7% in 147 patients. Both SaO2 (96.2 ± 2.9%, 95% confidence interval [CI] 95.7-96.7% vs. 95.1 ± 2.8%, 95% CI 94.7-95.6% and SpO2 (98.0 ± 2.6%, 95% CI 97.6-98.5% vs. 95.3 ± 2.8%, 95% CI 94.9-95.8% were significantly higher in patients with HbA1c >7% than in those with HbA1c ≤ 7% (Data are mean ± SD, all p 2 did not significantly differ between the two groups. Bland-Altman analysis demonstrated a significant bias between SpO2 and SaO2 (1.83 ±0.55%, 95% CI 1.73% -1.94% and limits of agreement (0.76% and 2.92% in patients with HbA1c >7%. The differences between SpO2 and SaO2 correlated closely with blood HbA1c levels (Pearson’s r = 0.307, p  Conclusions Elevated blood HbA1c levels lead to an overestimation of SaO2 by SpO2, suggesting that arterial blood gas analysis may be needed for type 2 diabetic patients with poor glycemic control during the treatment of hypoxemia.

  10. The impact of increasing oximetry usage in India: A pilot study

    Directory of Open Access Journals (Sweden)

    Gretl A McHugh

    2011-01-01

    Full Text Available The overall goal of the global oximetry (GO project was to increase patient safety during anaesthesia and surgery in low and middle income countries by decreasing oximetry costs and increasing oximetry utilisation. Results from the overall project have been previously published. This paper reports specifically on pilot work undertaken in four hospitals in one Indian State. The aim of this work was to assess the impact of increasing oximetry provision in terms of benefits to anaesthetists and in the identification of patient problems during anaesthesia, to identify training needs and to explore perceptions regarding barriers to more comprehensive oximetry coverage. Data collection was by interview with hospital staff, use of a log-book to capture data on desaturation episodes and a follow-up questionnaire at 10 months after the introduction of additional oximeters. Increasing oximetry utilisation in the four hospitals was viewed positively by the anaesthetic staff and enabled improvement in monitoring patients. Of the 939 monitored patients studied, 214 patients (23% experienced a total of 397 desaturation episodes. For nearly half of the patients undergoing caesarean section under regional anaesthesia following a desaturation event supplementary oxygen was required. In 53 of the 379 female sterilisations (14% desaturation episodes occurred and in eight patients, there were 17 episodes of desaturation due to obstruction. In the recovery room, 91 of the 939 patients were monitored using the oximeters with 12 patients (13% requiring oxygen. This study has highlighted that pulse oximetry must be used even in patients having surgical procedures or caesarean section under regional or local anaesthesia as these procedures are associated with hypoxic episodes. Anaesthetists must ensure they are complying with the Indian Society of Anaesthesiologists monitoring standards for anaesthesia and ensure patients are monitored by pulse oximetry.

  11. Interferência da coloração de esmaltes de unha e do tempo na oximetria de pulso em voluntários sadios Interference of nail polish colors and time on pulse oximetry in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Mara Harumi Miyake

    2003-12-01

    Full Text Available INTRODUÇÃO: A oximetria de pulso é um método não invasivo de mensuração da saturação periférica da oxiemoglobina (SpO2. É freqüentemente utilizado em unidades de emergência, de terapia intensiva e em centro cirúrgico. A leitura da oximetria de pulso tem acurácia limitada na presença de metaemoglobina, carboxiemoglobina, anemia, vasoconstrição periférica, esmalte de unha, luz fluorescente e movimentação. OBJETIVO: Avaliar a interferência da coloração de esmalte de unha e do tempo sobre a SpO2 em indivíduos sadios. MÉTODO: Participaram do estudo 61 voluntárias sadias, com idades entre 18 e 32 anos. Foi avaliada SpO2 nas seguintes colorações de esmaltes: base (dedo mínimo, rosa claro (dedo anular, rosa claro com cintilante (dedo médio e vermelha (polegar. O indicador não recebeu esmalte. Foi analisado o tempo para cada coloração de esmalte, a cada minuto até completar cinco minutos. RESULTADOS: Quando comparadas as medidas da SpO2 com o controle, as colorações base (p = 0,56, rosa claro (p = 0,56 e rosa claro com cintilante (p = 0,37 não apresentaram diferença estatisticamente significante. A SpO2 apresentou variação significante na cor vermelha (p BACKGROUND: Pulse oximetry is a noninvasive method to measure the saturation of peripheral oxyhaemoglobin (SpO2. It's usually used in emergency, intensive care and operating room units. Pulse oximeter readings have limited accuracy in the presence of methemoglobin, carboxyhemoglobin, anaemia, peripheral vasoconstriction, nail polish, fluorescent light, and motion. OBJECTIVES: To evaluate the interferences of the color of nail polishes and time on SpO2 in healthy individuals. METHODS: Sixty-one healthy female volunteers, ages ranging from 18 to 32 years. The nail polish colors used to evaluate SpO2 were: base coat on the little finger, light pink on the ring finger, sparkling light pink on the medium finger and red on the thumb. The index finger was used as control

  12. Accuracy of pulse oximetry in pigmented patients

    African Journals Online (AJOL)

    Reflectance was measured at nine wavelengths. Results. The degree of pigmentation as measured by ... adversely affected by skin pigmentation, and it remains a ... the inner surface of the upper arm and the volar aspect of ..... Ph.D. mesis.

  13. Free flap pulse oximetry utilizing reflectance photoplethysmography

    OpenAIRE

    Zaman, T.; Kyriacou, P. A.; Pal, S.

    2013-01-01

    The successful salvage of a free flap is dependent on the continuous monitoring of perfusion. To date there is no widely accepted and readily available post-operative monitoring technique to reliably assess the viability of free flaps by continuously monitoring free flap blood oxygen saturation. In an attempt to overcome the limitations of the current techniques a reflectance photoplethysmographic (PPG) processing system has been developed with the capability of real-time estimation of arteri...

  14. Cerebral oximetry in cardiac anesthesia

    Science.gov (United States)

    Vretzakis, George; Georgopoulou, Stauroula; Stamoulis, Konstantinos; Stamatiou, Georgia; Tsakiridis, Kosmas; Katsikogianis, Nikolaos; Kougioumtzi, Ioanna; Machairiotis, Nikolaos; Tsiouda, Theodora; Mpakas, Andreas; Beleveslis, Thomas; Koletas, Alexander; Siminelakis, Stavros N.; Zarogoulidis, Konstantinos

    2014-01-01

    Cerebral oximetry based on near-infrared spectroscopy (NIRS) is increasingly used during the perioperative period of cardiovascular operations. It is a noninvasive technology that can monitor the regional oxygen saturation of the frontal cortex. Current literature indicates that it can stratify patients preoperatively according their risk. Intraoperatively, it provides continuous information about brain oxygenation and allows the use of brain as sentinel organ indexing overall organ perfusion and injury. This review focuses on the clinical validity and applicability of this monitor for cardiac surgical patients. PMID:24672700

  15. Blood flow in the human fetal descending aorta : a pulsed Doppler study

    OpenAIRE

    Pijpers, Leendert

    1985-01-01

    textabstractIn 1628 William Harvey introduced his concept ofthe human circulation. Although a lot of studies concerning the fetal circulation were done before it was not until the 1930s that Barcroft (1934, 1939) and associates performed radiograpbic studies on the feta! goal and lamb to establish the feta! circulation. Later in 1964 Lind, Stern and Wegelius used cine-angiographic studies to describe the human fetal circulation. Volume flow measurements were already carried out in 1884 by Coh...

  16. The Study on the Adaptive Filtering Method for Eliminating the Motion Artifact in Pulse Oximetry Measurement%脉搏血氧饱和度检测中自适应滤波消除 运动伪差的方法研究

    Institute of Scientific and Technical Information of China (English)

    张虹; 孙卫新; 金捷

    2001-01-01

    Objective  The method of eliminating the motion artif ac t in the pulse oximetry measurement was studied in order to improve the performa nce character of the pulse oximeter. Methods  The noise paramete r was constructed by using light beat in the pulse oximetry system and the LMS(Lea st Mean Square) adaptive filter was used to eliminate the effect of motion artif act. Results  The algorithm of eliminating the motion artifact i n the pulse oximeter was developed. It can successfully extract the normal Photopl ethysmographic signal from the motion artifact in calculating oxygen saturation. Conclusion  This calculating method is simple and can be proces se d in real time, and its result is reliable. It establishes the fundament for fur ther decreasing the noise of pulse oximeter.%目的 研究脉搏血氧饱和度检测系统中运动伪差的消除方法, 以提高脉搏血氧仪检测性能。方法 通过脉搏血氧仪中的双光束构造噪声 参考信号,利用最小均方自适应滤波法消除运动伪差干扰的影响。结果  建立了脉搏血氧饱和度检测中消除运动伪差的计算方法,可成功地从运动伪差中提取正常光 电容积脉搏波信号作为计算氧饱和度的依据。结论 该计算方法简单,可 用于实时处理,且测量结果可靠,为进一步抑制脉搏血氧仪噪声奠定了基础。

  17. Blood flow in the human fetal descending aorta : a pulsed Doppler study

    NARCIS (Netherlands)

    L. Pijpers (Leendert)

    1985-01-01

    textabstractIn 1628 William Harvey introduced his concept ofthe human circulation. Although a lot of studies concerning the fetal circulation were done before it was not until the 1930s that Barcroft (1934, 1939) and associates performed radiograpbic studies on the feta! goal and lamb to establish t

  18. Biosynthesis of the D2 cell adhesion molecule: pulse-chase studies in cultured fetal rat neuronal cells

    DEFF Research Database (Denmark)

    Lyles, J M; Norrild, B; Bock, E

    1984-01-01

    D2 is a membrane glycoprotein that is believed to function as a cell adhesion molecule (CAM) in neural cells. We have examined its biosynthesis in cultured fetal rat brain neurones. We found D2-CAM to be synthesized initially as two polypeptides: Mr 186,000 (A) and Mr 136,000 (B). With increasing...... chase times the Mr of both molecules increased to 187,000-201,000 (A) and 137,000-158,000 (B). These were similar to the sizes of D2-CAM labeled with [14C]glucosamine, [3H]fucose and [14C]mannosamine, indicating that the higher Mr species are glycoproteins. In the presence of tunicamycin, which...... pulse or chase times, showing that these molecules are not interconverted. Thus, our data indicate that the neuronal D2-CAM glycoproteins are derived from two mRNAs....

  19. Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Eliasdottir, Thorunn Scheving; Bragason, David; Hardarson, Sveinn Hakon; Vacchiano, Charles; Gislason, Thorarinn; Kristjansdottir, Jona Valgerdur; Kristjansdottir, Gudrun; Stefánsson, Einar

    2017-01-01

    Determination of the blood oxyhemoglobin saturation in the retinal vessels of the eye can be achieved through spectrophotometric retinal oximetry which provides access to the state of oxyhemoglobin saturation in the central nervous system circulation. The purpose of this study was to test the capability of the Oxymap T1 oximeter to detect systemic hypoxemia and the effect of supplemental oxygen on retinal vessel oxyhemoglobin saturation. Oxygen saturation of hemoglobin in retinal arterioles and venules was measured in 11 subjects with severe chronic obstructive pulmonary disease (COPD) on long term oxygen therapy. Measurements were made with and without their daily supplemental oxygen. Eleven healthy age and gender matched subjects were measured during ambient air breathing for comparison of oxyhemoglobin saturation in retinal arterioles and venules. Retinal arteriolar oxyhemoglobin saturation in COPD subjects inspiring ambient air was compared with finger pulse oximetry and blood samples from radial artery. COPD subjects had significantly lower oxyhemoglobin saturation during ambient air breathing than healthy controls in both retinal arterioles (87.2%±4.9% vs. 93.4%±4.3%, p = 0.02; n = 11) and venules (45.0%±10.3% vs. 55.2%±5.5%, p = 0.01). Administration of their prescribed supplemental oxygen increased oxyhemoglobin saturation in retinal arterioles (87.2%±4.9% to 89.5%±6.0%, p = 0.02) but not in venules (45.0%±10.3% to 46.7%±12.8%, p = 0.3). Retinal oximetry values were slightly lower than radial artery blood values (mean percentage points difference = -5.0±5.4, 95% CI: -15.68 to 5.67) and finger pulse oximetry values (-3.1±5.5, 95% CI: -14.05 to 7.84). The noninvasive Oxymap T1 retinal oximetry detects hypoxemia in central nervous system vessels in patients with severe COPD compared with healthy controls. The instrument is sensitive to changes in oxygen breathing but displays slightly lower measures than finger pulse oximetry or radial artery

  20. Evaluation of Clinical Diagnosis of Fetal Distress and Perinatal Outcome in a Low Resource Nigerian Setting.

    Science.gov (United States)

    Ajah, Leonard Ogbonna; Ibekwe, Perpetus Chudi; Onu, Fidelis Agwu; Onwe, Ogah Emeka; Ezeonu, Thecla Chinonyelum; Omeje, Innocent

    2016-04-01

    Fetal distress has been shown to contribute to the increasing caesarean section rate. There has been controversy on the usefulness of clinical diagnosis of fetal distress using only the intermittent counting of the fetal heart rate and/or passage of meconium-stained liquor. To evaluate the clinical diagnosis of fetal distress and the perinatal outcome. This was a retrospective study in which the case records of the patients, who were diagnosed of fetal distress at Federal Teaching Hospital, Abakaliki, Nigeria, from January 1, 2008 to December 31, 2014, were collated. The statistical analysis was done using the Statistical Package for Social Sciences version 17 software (SPSS Inc., Chicago IL, USA). Out of the 15,640 deliveries carried out within the study period, 3,761 (24.05%) deliveries were through caesarean section. A total of 326 (8.9%) of the 3,761 caesarean sections were due to fetal distress within the study period. More so, a total of 227 (70.9%) babies were born with ≥ 7 Apgar score at the 1(st) minute of delivery. The perinatal mortality rate was 31.25 per 1000 deliveries. Though birth asphyxia was recorded more on babies of mothers that had fresh meconium-stained liquor and whose decision-intervention interval was more than 30 minutes when compared with those without any of the two conditions, there was no statistical significant difference between them. The clinical diagnosis of fetal distress is accurate in 29.1% of the cases. However, it has led to an unnecessary caesarean section in the remaining 70.9% of the parturients. In order to reduce this high trend of unnecessary caesarean sections due to clinical diagnosis of fetal distress in this environment, antepartum fetal assessment with non-stress test or biophysical profile and intrapartum use of continuous electronic fetal monitoring should be used to confirm or refute the fetal distress before any surgical intervention. Fetal blood sampling and fetal pulse oximetry should be performed in event

  1. A flexible infrared sensor for tissue oximetry

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Thyssen, Anders; Engholm, Mathias

    2013-01-01

    We present a flexible infrared sensor for use in tissue oximetry with the aim of treating prematurely born infants. The sensor will detect the oxygen saturation in brain tissue through near infrared spectroscopy. The sensor itself consists of several individual silicon photo detectors fully...... integrated in a flexible array. The flexibility is achieved by combining silicon with Polydimethylsiloxane and polyimide using standard IC manufacturing. This ensures that the electrical interconnects on the sensor can withstand being bent in order for the sensor to confine to the curved surface of the head...

  2. Review of splanchnic oximetry in clinical medicine

    Science.gov (United States)

    Bailey, Sean M.; Mally, Pradeep V.

    2016-09-01

    Global tissue perfusion and oxygenation are important indicators of physiologic function in humans. The monitoring of splanchnic oximetry through the use of near-infrared spectroscopy (NIRS) is an emerging method used to assess tissue oxygenation status. Splanchnic tissue oxygenation (SrS) is thought to be potentially of high value in critically ill patients because gastrointestinal organs can often be the first to suffer ischemic injury. During conditions of hypovolemia, cardiac dysfunction, or decreased oxygen-carrying capacity, blood flow is diverted toward vital organs, such as the brain and the heart at the expense of the splanchnic circulation. While monitoring SrS has great potential benefit, there are limitations to the technology and techniques. SrS has been found to have a relatively high degree of variability that can potentially make it difficult to interpret. In addition, because splanchnic organs only lie near the skin surface in children and infants, and energy from currently available sensors only penetrates a few centimeters deep, it can be difficult to use clinically in a noninvasive manner in adults. Research thus far is showing that splanchnic oximetry holds great promise in the ability to monitor patient oxygenation status and detect disease states in humans, especially in pediatric populations.

  3. Pulse

    Science.gov (United States)

    ... resting for at least 10 minutes. Take the exercise heart rate while you are exercising. ... pulse rate can help determine if the person's heart is pumping. Pulse ... rate gives information about your fitness level and health.

  4. Cerebral near infrared spectroscopy oximetry in extremely preterm infants

    DEFF Research Database (Denmark)

    Hyttel-Sorensen, Simon; Pellicer, Adelina; Alderliesten, Thomas

    2015-01-01

    OBJECTIVE: To determine if it is possible to stabilise the cerebral oxygenation of extremely preterm infants monitored by cerebral near infrared spectroscopy (NIRS) oximetry. DESIGN: Phase II randomised, single blinded, parallel clinical trial. SETTING: Eight tertiary neonatal intensive care units...

  5. Cerebral near infrared spectroscopy oximetry in extremely preterm infants

    DEFF Research Database (Denmark)

    Hyttel-Sorensen, Simon; Pellicer, Adelina; Alderliesten, Thomas;

    2015-01-01

    OBJECTIVE: To determine if it is possible to stabilise the cerebral oxygenation of extremely preterm infants monitored by cerebral near infrared spectroscopy (NIRS) oximetry. DESIGN: Phase II randomised, single blinded, parallel clinical trial. SETTING: Eight tertiary neonatal intensive care units...

  6. Development of a luminous textile for reflective pulse oximetry measurements

    Science.gov (United States)

    Krehel, Marek; Wolf, Martin; Boesel, Luciano F.; Rossi, René M.; Bona, Gian-Luca; Scherer, Lukas J.

    2014-01-01

    In this paper, a textile-based sensing principle for long term photopletysmography (PPG) monitoring is presented. Optical fibers were embroidered into textiles such that out-coupling and in-coupling of light was possible. The “light-in light-out” properties of the textile enabled the spectroscopic characterization of human tissue. For the optimization of the textile sensor, three different carrier fabrics and different fiber modifications were compared. The sample with best light coupling efficiency was successfully used to measure heart rate and SpO2 values of a subject. The latter was determined by using a modified Beer-Lambert law and measuring the light attenuation at two different wavelengths (632 nm and 894 nm). Moreover, the system was adapted to work in reflection mode which makes the sensor more versatile. The measurements were additionally compared with commercially available system and showed good correlation. PMID:25136484

  7. Development of a luminous textile for reflective pulse oximetry measurements.

    Science.gov (United States)

    Krehel, Marek; Wolf, Martin; Boesel, Luciano F; Rossi, René M; Bona, Gian-Luca; Scherer, Lukas J

    2014-08-01

    In this paper, a textile-based sensing principle for long term photopletysmography (PPG) monitoring is presented. Optical fibers were embroidered into textiles such that out-coupling and in-coupling of light was possible. The "light-in light-out" properties of the textile enabled the spectroscopic characterization of human tissue. For the optimization of the textile sensor, three different carrier fabrics and different fiber modifications were compared. The sample with best light coupling efficiency was successfully used to measure heart rate and SpO2 values of a subject. The latter was determined by using a modified Beer-Lambert law and measuring the light attenuation at two different wavelengths (632 nm and 894 nm). Moreover, the system was adapted to work in reflection mode which makes the sensor more versatile. The measurements were additionally compared with commercially available system and showed good correlation.

  8. Avaliação das medidas de oximetria de pulso em indivíduos sadios com esmalte de unha Evaluación de las medidas de oximetría de pulso en individuos sanos con esmalte de uña Evaluation of pulse oximetry measurements in healthy subjects with nail polish

    Directory of Open Access Journals (Sweden)

    Solange Diccini

    2011-01-01

    Full Text Available OBJETIVO: Avaliar as alterações nas medidas da oximetria de pulso em indivíduos sadios com esmaltes de unha. MÉTODOS: Estudo transversal com 80 voluntárias sadias. As cores de esmalte utilizadas para avaliar a saturação periférica de oxigênio (SpO2 foram: café com leite, café, chocolate, vermelho e ameixa. Estas cores foram distribuídas entre as unhas dos dedos da mão esquerda. Os dedos da mão direita foram os controles. RESULTADOS: As cores vermelha (p=0,047 e café (p=0,024 mostraram valores menores na SpO2 quando comparados ao controle. As outras cores não alteraram a medida da SpO2. CONCLUSÃO: As cores vermelha e café causaram redução na medida da SpO2, porém a relevância clínica deste achado é questionável, pois os valores estavam dentro do intervalo de normalidade.OBJETIVO: Evaluar las alteraciones en las medidas de la oximetría de pulso en individuos sanos con esmalte de uña. MÉTODOS: Estudio transversal realizado con 80 voluntarias sanas. Los colores de esmalte utilizados para evaluar la saturación periférica de oxígeno (SpO2 fueron: café con leche, café, chocolate, rojo y ciruela. Estos colores fueron distribuidos entre las uñas de los dedos de la mano izquierda. Los dedos de la mano derecha fueron los controles. RESULTADOS: Los colores rojo (p=0,047 y café (p=0,024 mostraron valores menores en la SpO2 cuando fueron comparados al control. Los otros colores no alteraron la medida del SpO2. CONCLUSIÓN: Los colores rojo y café causaron reducción en la medida del SpO2, sin embargo la relevancia clínica de este hallazgo es cuestionable, pues los valores estaban dentro del intervalo de normalidad.OBJECTIVE: To evaluate the changes in measurements of pulse oximetry in healthy individuals with nail polish. METHODS: Cross sectional study with 80 healthy volunteers. The colors of enamel used to assess oxygen saturation (SpO2 were: coffee with milk, coffee, chocolate, red and plum. These colors were

  9. Application of ESR spin label oximetry in food science.

    Science.gov (United States)

    Zhou, Yu-Ting; Yin, Jun-Jie; Lo, Y Martin

    2011-12-01

    Lipid oxidation attributed to the presence of oxygen has long been a focal area for food science research due in early years mainly to its broad impact on the quality and shelf stability. The need to effectively strategize interventions to detect and eventually eliminate lipid oxidation in food remains as evidence on nutritional and health implications continue to accumulate. Electron spin resonance (ESR) spin label oximetry has been shown capable of detecting dissolved oxygen concentration in both liquid and gaseous phases based on the collision between oxygen and stable free radicals. This review aimed to summarize not just the principles and rationale of ESR spin label oximetry but also the wide spectrum of ESR spin label oximetry applications to date. The feasibility to identify in very early stage oxygen generation and consumption offers a promising tool for controlling lipid oxidation in food and biological systems.

  10. Fetal Circulation

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Circulation Updated:Oct 18,2016 click to enlarge The ... fetal heart. These two bypass pathways in the fetal circulation make it possible for most fetuses to survive ...

  11. [Wavelength selection of the oximetry based on test analysis of variance].

    Science.gov (United States)

    Lin, Ling; Li, Wei; Zeng, Rui-Li; Liu, Rui-An; Li, Gang; Wu, Xiao-Rong

    2014-07-01

    In order to improve the precision and reliability of the spectral measurement of blood oxygen saturation, and enhance the validity of the measurement, the method of test analysis of variance was employed. Preferred wavelength combination was selected by the analysis of the distribution of the coefficient of oximetry at different wavelength combinations and rational use of statistical theory. Calculated by different combinations of wavelengths (660 and 940 nm, 660 and 805 nm and 805 and 940 nm) through the clinical data under different oxygen saturation, the single factor test analysis of variance model of the oxygen saturation coefficient was established, the relative preferabe wavelength combination can be selected by comparative analysis of different combinations of wavelengths from the photoelectric volume pulse to provide a reliable intermediate data for further modeling. The experiment results showed that the wavelength combination of 660 and 805 nm responded more significantly to the changes in blood oxygen saturation and the introduced noise and method error were relatively smaller of this combination than other wavelength combination, which could improve the measurement accuracy of oximetry. The study applied the test variance analysis to the selection of wavelength combination in the blood oxygen result measurement, and the result was significant. The study provided a new idea for the blood oxygen measurements and other related spectroscopy quantitative analysis. The method of test analysis of variance can help extract the valid information which represents the measured values from the spectrum.

  12. Pulse Oxigraphy: And other new in-depth perspectives through the near infrared window

    NARCIS (Netherlands)

    F.P. Wieringa

    2007-01-01

    textabstractThe aim of this thesis was to investigate the feasability of contactless imaging pulse oximetry (proposed term: pulse oxigraphy). The patent disclosed in chapter 2 claims that such pulse oxigraphy can be achieved with camera-derived photoplethysmographic pulse waves at three wavelengt

  13. Effects of manual chest compression and descompression maneuver on lung volumes, capnography and pulse oximetry in patients receiving mechanical ventilation Efeitos da manobra de compressão e descompressão torácica nos volumes pulmonares, capnografia e oximetria de pulso em pacientes submetidos à ventilação mecânica

    Directory of Open Access Journals (Sweden)

    Fabiana Della Via

    2012-10-01

    Full Text Available OBJECTIVES: The aims of this study were to evaluate whether there are changes in lung volumes, capnography, pulse oximetry and hemodynamic parameters associated with manual chest compression-decompression maneuver (MCCD in patients undergoing mechanical ventilation (MV. Method: A prospective study of 65 patients undergoing to MV after 24 hours. All patients received bronchial hygiene maneuvers and after 30 minutes they were submitted to ten repetitions of the MCCD during 10 consecutive respiratory cycles in the right hemithorax and than in the left hemithorax. The data were collected before the application of the maneuver and after 1, 5, 10, 15, 20, 25, 30, 35 and 40 minutes following application of the maneuver. RESULTS: There were statistical significant (pOBJETIVOS: Avaliar a presença de alterações nos volumes pulmonares, oximetria de pulso, capnografia e alterações hemodinâmicas associadas à intervenção da manobra de compressão e descompressão torácica (MCDT nos pacientes submetidos à ventilação mecânica (VM. Método: Tratou-se de um estudo prospectivo em que foram incluídos 65 pacientes em VM há mais de 24 horas. O protocolo consistiu na aplicação de manobras de higiene brônquica e, após 30 minutos, os pacientes eram submetidos a dez repetições da MCDT em dez respirações consecutivas no hemitórax direito e, posteriormente, no hemitórax esquerdo, coletando os dados antes e após a aplicação da manobra nos tempos 1, 5, 10, 15, 20, 25, 30, 35 e 40 minutos. RESULTADOS: Constatou-se aumento significante (p<0,001 do volume corrente inspiratório (pré: 458,2±132,1 ml; pós 1 minuto: 557,3±139,1; pós 40 minutos: 574,4±151, volume minuto corrente (pré: 7,0±2,7 L/min; pós 1 minuto: 8,7±3,3; pós 40 minutos: 8,8±3,8 e oximetria de pulso (pré: 97,4±2,2%; pós 1 minuto: 97,9±1,8; pós 40 minutos: 98,2±1,6; p<0,05. Ocorreu redução no CO2 expirado (pré: 35,1±9,0 mmHg; pós 1 minuto: 31,5±8,2; pós 40

  14. Fetal Research

    Science.gov (United States)

    Hansen, John T.; Sladek, John R.

    1989-11-01

    This article reviews some of the significant contributions of fetal research and fetal tissue research over the past 20 years. The benefits of fetal research include the development of vaccines, advances in prenatal diagnosis, detection of malformations, assessment of safe and effective medications, and the development of in utero surgical therapies. Fetal tissue research benefits vaccine development, assessment of risk factors and toxicity levels in drug production, development of cell lines, and provides a source of fetal cells for ongoing transplantation trials. Together, fetal research and fetal tissue research offer tremendous potential for the treatment of the fetus, neonate, and adult.

  15. Parameters from preoperative overnight oximetry predict postoperative adverse events.

    Science.gov (United States)

    Chung, F; Zhou, L; Liao, P

    2014-10-01

    Continuous home monitoring of oxygen saturation has become a reliable and feasible practice. The objective of this study was to investigate the role of preoperative overnight oximetry in predicting postoperative adverse events. Following research ethics board approval, consented patients underwent a preoperative overnight monitoring of oxygen saturation with a portable oximeter. Parameters from the oximetry data were extracted and their predictive performance for postoperative adverse events was evaluated. A total of 573 patients were studied with age: 60±12 years and 45% male. Oxygen desaturation index (ODI), cumulative time percentage with SpO2 3.0 events/h, >9.2 events/h and > 28.5 events/h; CT90: >0.1%, >1.1% and >7.2%; mean SpO2: rate of postoperative adverse events. For ODI >28.5 vs. ODI ⋝28.5 events/h, the odds ratio adjusted with age, gender, body mass index and American Society of Anesthesiologists physical status was 2.2 (95% CI: 1.3-3.9). Patients with mean preoperative overnight SpO2 28.5 events/h or CT90 >7.2% are at higher risk for postoperative adverse events. Overnight oximetry could be a useful tool to stratify patients for the risk of postoperative adverse events.

  16. Retinal oximeter for the blue-green oximetry technique

    Science.gov (United States)

    Denninghoff, Kurt R.; Sieluzycka, Katarzyna B.; Hendryx, Jennifer K.; Ririe, Tyson J.; Deluca, Lawrence; Chipman, Russell A.

    2011-10-01

    Retinal oximetry offers potential for noninvasive assessment of central venous oxyhemoglobin saturation (SO2) via the retinal vessels but requires a calibrated accuracy of +/-3% saturation in order to be clinically useful. Prior oximeter designs have been hampered by poor saturation calibration accuracy. We demonstrate that the blue-green oximetry (BGO) technique can provide accuracy within +/-3% in swine when multiply scattered light from blood within a retinal vessel is isolated. A noninvasive on-axis scanning retinal oximeter (ROx-3) is constructed that generates a multiwavelength image in the range required for BGO. A field stop in the detection pathway is used in conjunction with an anticonfocal bisecting wire to remove specular vessel reflections and isolate multiply backscattered light from the blood column within a retinal vessel. This design is tested on an enucleated swine eye vessel and a retinal vein in a human volunteer with retinal SO2 measurements of ~1 and ~65%, respectively. These saturations, calculated using the calibration line from earlier work, are internally consistent with a standard error of the mean of +/-2% SO2. The absolute measures are well within the expected saturation range for the site (-1 and 63%). This is the first demonstration of noninvasive on-axis BGO retinal oximetry.

  17. ROx3: Retinal oximetry utilizing the blue-green oximetry method

    Science.gov (United States)

    Parsons, Jennifer Kathleen Hendryx

    The ROx is a retinal oximeter under development with the purpose of non-invasively and accurately measuring oxygen saturation (SO2) in vivo. It is novel in that it utilizes the blue-green oximetry technique with on-axis illumination. ROx calibration tests were performed by inducing hypoxia in live anesthetized swine and comparing ROx measurements to SO 2 values measured by a CO-Oximeter. Calibration was not achieved to the precision required for clinical use, but limiting factors were identified and improved. The ROx was used in a set of sepsis experiments on live pigs with the intention of tracking retinal SO2 during the development of sepsis. Though conclusions are qualitative due to insufficient calibration of the device, retinal venous SO2 is shown to trend generally with central venous SO2 as sepsis develops. The novel sepsis model developed in these experiments is also described. The method of cecal ligation and perforation with additional soiling of the abdomen consistently produced controllable severe sepsis/septic shock in a matter of hours. In addition, the ROx was used to collect retinal images from a healthy human volunteer. These experiments served as a bench test for several of the additions/modifications made to the ROx. This set of experiments specifically served to illuminate problems with various light paths and image acquisition. The analysis procedure for the ROx is under development, particularly automating the process for consistency, accuracy, and time efficiency. The current stage of automation is explained, including data acquisition processes and the automated vessel fit routine. Suggestions for the next generation of device minimization are also described.

  18. Vigilancia Fetal

    OpenAIRE

    SAONA UGARTE, Pedro

    2013-01-01

    La percepción de la actividad fetal por la madre es la técnica más antigua y menos costosa de controlar el bienestar fetal. Tradicionalmente se ha considerado la disminución o ausencia de movimientos fetales percibidos por la madre, como una señal de alarma, en especial cuando existe insuficiencia útero placentaria. Varios investigadores han descrito el valor del registro diario de movimientos fetales como un método para identificar el feto en peligrote morir. El poder discernir si el feto se...

  19. {sup 19}F MRI oximetry: simulation of perfluorocarbon distribution impact

    Energy Technology Data Exchange (ETDEWEB)

    Baete, S H; Vandecasteele, J; De Deene, Y, E-mail: steven.baete@ugent.be [Department of Radiation Oncology and Experimental Cancer Research, Ghent University, De Pintelaan 185, 9000 Gent (Belgium)

    2011-04-21

    In {sup 19}F MRI oximetry, a method used to image tumour hypoxia, perfluorocarbons serve as oxygenation markers. The goal of this study is to evaluate the impact of perfluorocarbon distribution and concentration in {sup 19}F MRI oximetry through a computer simulation. The simulation studies the correspondence between {sup 19}F measured (pO{sup FNMR}{sub 2}) and actual tissue oxygen tension (pO{sub 2}) for several tissue perfluorocarbon distributions. For this, a Krogh tissue model is implemented which incorporates the presence of perfluorocarbons in blood and tissue. That is, in tissue the perfluorocarbons are distributed homogeneously according to Gaussian diffusion profiles, or the perfluorocarbons are concentrated in the capillary wall. Using these distributions, the oxygen tension in the simulation volume is calculated. The simulated mean oxygen tension is then compared with pO{sup FNMR}{sub 2}, the {sup 19}F MRI-based measure of pO{sub 2} and with pO{sup 0}{sub 2}, pO{sub 2} in the absence of perfluorocarbons. The agreement between pO{sup FNMR}{sub 2} and actual pO{sub 2} is influenced by vascular density and perfluorocarbon distribution. The presence of perfluorocarbons generally gives rise to a pO{sub 2} increase in tissue. This effect is enhanced when perfluorocarbons are also present in blood. Only the homogeneous perfluorocarbon distribution in tissue with no perfluorocarbons in blood guarantees small deviations of pO{sup FNMR}{sub 2} from pO{sub 2}. Hence, perfluorocarbon distribution in tissue and blood has a serious impact on the reliability of {sup 19}F MRI-based measures of oxygen tension. In addition, the presence of perfluorocarbons influences the actual oxygen tension. This finding may be of great importance for further development of {sup 19}F MRI oximetry.

  20. 19F MRI oximetry: simulation of perfluorocarbon distribution impact

    Science.gov (United States)

    Baete, S. H.; Vandecasteele, J.; De Deene, Y.

    2011-04-01

    In 19F MRI oximetry, a method used to image tumour hypoxia, perfluorocarbons serve as oxygenation markers. The goal of this study is to evaluate the impact of perfluorocarbon distribution and concentration in 19F MRI oximetry through a computer simulation. The simulation studies the correspondence between 19F measured (pOFNMR2) and actual tissue oxygen tension (pO2) for several tissue perfluorocarbon distributions. For this, a Krogh tissue model is implemented which incorporates the presence of perfluorocarbons in blood and tissue. That is, in tissue the perfluorocarbons are distributed homogeneously according to Gaussian diffusion profiles, or the perfluorocarbons are concentrated in the capillary wall. Using these distributions, the oxygen tension in the simulation volume is calculated. The simulated mean oxygen tension is then compared with pOFNMR2, the 19F MRI-based measure of pO2 and with pO02, pO2 in the absence of perfluorocarbons. The agreement between pOFNMR2 and actual pO2 is influenced by vascular density and perfluorocarbon distribution. The presence of perfluorocarbons generally gives rise to a pO2 increase in tissue. This effect is enhanced when perfluorocarbons are also present in blood. Only the homogeneous perfluorocarbon distribution in tissue with no perfluorocarbons in blood guarantees small deviations of pOFNMR2 from pO2. Hence, perfluorocarbon distribution in tissue and blood has a serious impact on the reliability of 19F MRI-based measures of oxygen tension. In addition, the presence of perfluorocarbons influences the actual oxygen tension. This finding may be of great importance for further development of 19F MRI oximetry.

  1. Green Light Pulse Oximeter

    Energy Technology Data Exchange (ETDEWEB)

    Scharf, John Edward (Oldsmar, FL)

    1998-11-03

    A reflectance pulse oximeter that determines oxygen saturation of hemoglobin using two sources of electromagnetic radiation in the green optical region, which provides the maximum reflectance pulsation spectrum. The use of green light allows placement of an oximetry probe at central body sites (e.g., wrist, thigh, abdomen, forehead, scalp, and back). Preferably, the two green light sources alternately emit light at 560 nm and 577 nm, respectively, which gives the biggest difference in hemoglobin extinction coefficients between deoxyhemoglobin, RHb, and oxyhemoglobin, HbO.sub.2.

  2. Assessing diabetic foot ulcer development risk with hyperspectral tissue oximetry

    Science.gov (United States)

    Yudovsky, Dmitry; Nouvong, Aksone; Schomacker, Kevin; Pilon, Laurent

    2011-02-01

    Foot ulceration remains a serious health concern for diabetic patients and has a major impact on the cost of diabetes treatment. Early detection and preventive care, such as offloading or improved hygiene, can greatly reduce the risk of further complications. We aim to assess the use of hyperspectral tissue oximetry in predicting the risk of diabetic foot ulcer formation. Tissue oximetry measurements are performed during several visits with hyperspectral imaging of the feet in type 1 and 2 diabetes mellitus subjects that are at risk for foot ulceration. The data are retrospectively analyzed at 21 sites that ulcerated during the course of our study and an ulceration prediction index is developed. Then, an image processing algorithm based on this index is implemented. This algorithm is able to predict tissue at risk of ulceration with a sensitivity and specificity of 95 and 80%, respectively, for images taken, on average, 58 days before tissue damage is apparent to the naked eye. Receiver operating characteristic analysis is also performed to give a range of sensitivity/specificity values resulting in a Q-value of 89%.

  3. Oximetry Signal Processing Identifies REM Sleep-Related Vulnerability Trait in Asthmatic Children

    Science.gov (United States)

    Perez, Geovanny F.; Gutierrez, Maria J.; Huseni, Shehlanoor; Pancham, Khrisna; Rodriguez-Martinez, Carlos E.; Nino, Cesar L.; Nino, Gustavo

    2013-01-01

    Rationale. The sleep-related factors that modulate the nocturnal worsening of asthma in children are poorly understood. This study addressed the hypothesis that asthmatic children have a REM sleep-related vulnerability trait that is independent of OSA. Methods. We conducted a retrospective cross-sectional analysis of pulse-oximetry signals obtained during REM and NREM sleep in control and asthmatic children (n = 134). Asthma classification was based on preestablished clinical criteria. Multivariate linear regression model was built to control for potential confounders (significance level P ≤ 0.05). Results. Our data demonstrated that (1) baseline nocturnal respiratory parameters were not significantly different in asthmatic versus control children, (2) the maximal % of SaO2 desaturation during REM, but not during NREM, was significantly higher in asthmatic children, and (3) multivariate analysis revealed that the association between asthma and REM-related maximal % SaO2 desaturation was independent of demographic variables. Conclusion. These results demonstrate that children with asthma have a REM-related vulnerability trait that impacts oxygenation independently of OSA. Further research is needed to delineate the REM sleep neurobiological mechanisms that modulate the phenotypical expression of nocturnal asthma in children. PMID:24288619

  4. Oximetry Signal Processing Identifies REM Sleep-Related Vulnerability Trait in Asthmatic Children

    Directory of Open Access Journals (Sweden)

    Geovanny F. Perez

    2013-01-01

    Full Text Available Rationale. The sleep-related factors that modulate the nocturnal worsening of asthma in children are poorly understood. This study addressed the hypothesis that asthmatic children have a REM sleep-related vulnerability trait that is independent of OSA. Methods. We conducted a retrospective cross-sectional analysis of pulse-oximetry signals obtained during REM and NREM sleep in control and asthmatic children (n=134. Asthma classification was based on preestablished clinical criteria. Multivariate linear regression model was built to control for potential confounders (significance level P≤0.05. Results. Our data demonstrated that (1 baseline nocturnal respiratory parameters were not significantly different in asthmatic versus control children, (2 the maximal % of SaO2 desaturation during REM, but not during NREM, was significantly higher in asthmatic children, and (3 multivariate analysis revealed that the association between asthma and REM-related maximal % SaO2 desaturation was independent of demographic variables. Conclusion. These results demonstrate that children with asthma have a REM-related vulnerability trait that impacts oxygenation independently of OSA. Further research is needed to delineate the REM sleep neurobiological mechanisms that modulate the phenotypical expression of nocturnal asthma in children.

  5. Fetal Macrosomia

    Science.gov (United States)

    ... might need special care in the hospital's neonatal intensive care unit. Keep in mind that your baby might ... References Copel JA, et al. Fetal macrosomia. In: Obstetric Imaging. Philadelphia, Pa.: Saunders Elsevier; 2012. http://www. ...

  6. Fetal Ultrasound

    Science.gov (United States)

    ... needle placement during certain prenatal tests, such as amniocentesis or chorionic villus sampling. Determine fetal position before ... home. Accessed Aug. 11, 2015. Ghidini A. Diagnostic amniocentesis. http://www.uptodate.com/home. Accessed Aug. 11, ...

  7. Fetal blood flow measurements in severe rhesus isoimmunization. A case report.

    Science.gov (United States)

    Stiller, R J; Ashmead, G G; Paul, D; Weiner, S

    1987-06-01

    Maternal isoimmunization can result in fetal anemia. Current management of isoimmunized pregnancies involves amniocentesis and spectrophotometry. Pulsed Doppler ultrasound can provide fetal blood flow determinations from the fetal umbilical vein. A pregnancy complicated by severe rhesus isoimmunization was studied with Doppler ultrasound. Increased fetal umbilical blood flow was associated with increased fetal hemolysis. Umbilical vein blood flow decreased after intrauterine transfusion. Doppler ultrasound assessment of fetal blood flow is a useful noninvasive adjunct in isoimmunized pregnancies.

  8. Fetal pain

    OpenAIRE

    Adama van Scheltema, Phebe

    2011-01-01

    Recent studies have suggested that the fetus is capable of exhibiting a stress response to intrauterine needling, resulting in alterations in fetal stress hormone levels. Intrauterine transfusions are performed by inserting a needle either in the umbilical cord root at the placental surface (PCI), or in the intrahepatic portion of the umbilical vein (IHV). Aim of our study was to test the hypothesis that fetal hormonal changes during intrauterine transfusion are more pronounced when the needl...

  9. [Fetal magnetocardiography].

    Science.gov (United States)

    van Leeuwen, P

    1997-09-01

    Fetal magnetocardiography is a new, alternative method for prenatal surveillance. The fetal magnetocardiogram (FMCG) registers the magnetic field produced by conduction currents in the fetal heart. Compared to the fetal electrocardiogram, the propagation of magnetic fields is relatively undisturbed by surrounding tissue. The FMCG thus has the advantage of a higher signal-to-noise ratio and can be acquired earlier pregnancy. Also, the high temporal resolution of the signal permits a significantly more precise determination of fetal heart rate parameters than fetal ultrasound. FMCG registration using a biomagnetometer is noninvasive and can be performed as of the second trimeter. It can be used to examine signal morphology, cardiac time intervals, heart rate variability as well as cardiac magnetic fields. To date, arrhythmic activity has been observed in the form of supraventricular and ventricular ectopies as well as atrial flutter, atrio-ventricular block, atrial tachycardia and Torsades de Pointes tachycardia. We also report here on the presence of short episodes of bradycardia in the second trimester of normal pregnancy. Measurement of the magnetic field strength at various locations above the abdomen has allowed the reconstruction of the fetal cardiac magnetic field and the determination of its relation to the position of the fetus. Signal averaging has permitted the precise examination of signal amplitude and cardiac time intervals and has shown that they increase in the course of pregnancy. Heart rate variability could be quantified in the time and frequency domain as well as using parameters of nonlinear dynamics. The results demonstrated an increase of variability and complexity over gestational age. Furthermore spectral analysis of fetal heart arte data could be associated with sympathetic and parasympathetic activity as well as, with respiration. Although the studies presenting these results have involved only limited numbers of observations, they

  10. Pulse oximeter accuracy and precision at five different sensor locations in infants and children with cyanotic heart disease

    Directory of Open Access Journals (Sweden)

    Jyotirmoy Das

    2010-01-01

    Full Text Available Since the invention of pulse oximetry by Takuo Aoyagi in the early 1970s, its use has expanded beyond the perioperative care into neonatal, paediatric and adult intensive care units (ICUs. Pulse oximetry is one of the most important advances in respiratory monitoring as its readings (SpO 2 are used clinically as an indirect estimation of arterial oxygen saturation (SaO 2 . Sensors were placed frequently on the sole, palm, ear lobe or toes in addition to finger. On performing an extensive Medline search using the terms "accuracy of pulse oximetry" and "precision of pulse oximetry", limited data were found in congenital heart disease patients in the immediate post-corrective stage. Also, there are no reports and comparative data of the reliability and precision of pulse oximetry when readings from five different sensor locations (viz. finger, palm, toe, sole and ear are analysed simultaneously. To fill these lacunae of knowledge, we undertook the present study in 50 infants and children with cyanotic heart disease in the immediate post-corrective stage.

  11. A finger-free wrist-worn pulse oximeter for the monitoring of chronic obstructive pulmonary disease

    Science.gov (United States)

    Chu, Chang-Sheng; Chuang, Shuang-Chao; Lee, Yeh Wen; Fan, Chih-Hsun; Chung, Lung Pin; Li, Yu-Tang; Chen, Jyh-Chern

    2016-03-01

    Herein, a finger-free wrist-worn pulse oximeter is presented. This device allows patients to measure blood oxygen level and pulse rate without hindering their normal finger movement. This wrist-worn pulse oximeter is built with a reflectance oximetry sensor, which consists of light emitting diodes and photodiode light detectors located side by side. This reflectance oximetry sensor is covered with an optical element with micro structured surface. This micro structured optical element is designed to modulate photon propagation beneath the skin tissue so that the photoplethysmogram signals of reflected lights or backscattered lights detected by the photodetector are therefore enhanced.

  12. Fetal pain

    NARCIS (Netherlands)

    Adama van Scheltema, Phebe

    2011-01-01

    Recent studies have suggested that the fetus is capable of exhibiting a stress response to intrauterine needling, resulting in alterations in fetal stress hormone levels. Intrauterine transfusions are performed by inserting a needle either in the umbilical cord root at the placental surface (PCI), o

  13. Visible light optical coherence tomography for microvascular oximetry in ocular circulation (Conference Presentation)

    Science.gov (United States)

    Chen, Siyu; Yi, Ji; Zhang, Hao F.

    2016-03-01

    Visible light optical coherence tomography (vis-OCT) is intrinsically capable of optical determination of blood oxygen saturation (sO2). Thanks to its 3D sectioning ability, confounding factors that plaque multi-wavelength fundus photography can be avoided. We further supplemented it with motion-enhanced angiography (vis-OCTA), which allowed us to resolve retinal micro vessels without losing spectral information. As a result, spectroscopic vis-OCTA can extract microvascular sO2 which are generally inaccessible. Here we extend the theoretical formulation of vis-OCTA oximetry to include optical attenuation, scattering and motion contrast. The model allows robust estimation of sO2, while also promising reduction of illuminating power to 1/3 of current value of ~1 mW. To demonstrate the capability of our approach, we performed oxygen challenge while taking vis-OCTA measurements on rat ocular circulation in vivo. We supplied the experiment animal with the following gas mixture: normal air, 5% CO2 air, pure O2 and 10% O2 air. For each inhalation gas, the OCTA measurements were compared with peripheral capillary sO2 (spO2) provided by a pulse oximeter. The retinal artery sO2 measurements corresponded well with spO2 reading as expected (R2 = 0.87). We found that both retinal and choroidal circulation sO2 moderately increased when we supplied 5% CO2 air. 100% O2 inhalation significantly increased both artery and vein oxygenation. On the contrary, 10% O2 air could deplete the oxygen reservoir in the circulation and lead to low sO2 readings.

  14. Percutaneous nocturnal oximetry in amyotrophic lateral sclerosis: periodic desaturation.

    Science.gov (United States)

    de Carvalho, Mamede; Costa, João; Pinto, Susana; Pinto, Anabela

    2009-06-01

    Percutaneous nocturnal oximetry (PNO) is useful to screen respiratory function in amyotrophic lateral sclerosis (ALS). PNO recordings of some patients disclose a periodical pattern of O(2) desaturation (PP), whose significance is unknown. We aimed to characterize PP pattern, and we used a prospective study enrolling 261 consecutive ALS patients. Clinical, pulmonary and neurophysiological tests performed included: ALS functional rating scale, forced vital capacity (FVC), maximal inspiratory pressure (PImax), mouth occlusion pressure (MOP), phrenic nerve motor response, needle electromyography of the diaphragm, PNO, and sleep study. A total of 837 PNO recordings were analysed (3.2 recordings/patient) and 45 patients showed typical PP (17.2%). Four were excluded, 13 had normal diaphragm (group 1, G1), and in 28 the diaphragm was abnormal (G2). The two groups were comparable, apart from respiratory score, FVC and PImax which were lower in G2. In G1, REM sleep was absent and hypoventilation occurred at slow-wave sleep. Five patients in G1 were very spastic, had low MOP/FVC and a short survival. This study identified a subgroup of ALS patients (G1) with marked signs of upper motor neuron lesion, strong respiratory muscles, PP, low MOP/FVC ratio and poor prognosis. We speculate that they have a central respiratory dysfunction and deserve special care.

  15. The use of pulsed-wave Doppler in prenatal diagnosis. An update

    OpenAIRE

    DEGANI, S.

    2007-01-01

    Pulsed wave Doppler ultrasound of fetal vessels confirms the similarity of human fetal circulation to the experimental animal physiology, The result of a multitude of research articles in this field is the clinical use of various components of fetal circulation in perinatal medicine. Umbilical, uterine and fetal cerebral arteries as well as the fetal venous circulation show the potential of Doppler ultrasonography.

  16. Oximetry: a reflective tool for the detection of physiological expression of emotions in a science education classroom

    Science.gov (United States)

    Calderón, Olga

    2016-09-01

    The pulse oximeter is a device that measures the oxygen concentration (or oxygen saturation—SpO2); heart rate, and heartbeat of a person at any given time. This instrument is commonly used in medical and aerospace fields to monitor physiological outputs of a patient according to health conditions or physiological yields of a flying pilot according to changes in altitude and oxygen availability in the atmosphere. Nonetheless, the uses for pulse oximetry may expand to other fields where there is human interaction and where physiological outputs reflect fluctuations mediated by arising emotions. A classroom, for instance is filled with a plethora of emotions, but very often participants in this space are unaware of others' or their own sentiments as these arise as a result of interactions and responses to class discussions. In this paper I describe part of a larger study-taking place at Brooklyn College of the City University of New York. The focus is on the exploration of emotions and mindfulness in the science classroom. The oximeter is used in this study as a reflexive tool to detect emotions emerging among participants of a graduate History and Philosophy of Science Education course offered in the spring of 2012. Important physiological information of class participants provided by the oximeter is used to analyze the role of emotions in the classroom as sensitive and controversial topics in science education are discussed every week.

  17. Combined pulse-oximeter-NIRS system for biotissue diagnostics

    Science.gov (United States)

    Hovhannisyan, Vladimir A.

    2005-08-01

    Multi-wavelength (670, 805, 848 and 905 nm), multi-detector device for non-invasive measurement of biochemical components concentration in human or animal tissues, combining the methods of conventional pulse-oximetry and near infrared spectroscopy, is developed. The portable and clinically applicable system allows to measure heart pulse rate, oxygen saturation of arterial hemoglobin (pulse-oximetry method) and local absolute concentration of oxyhemoglobin, deoxyhemoglobin and oxidized cytochrome aa3 or other IR absorbed compounds (NIRS method). The system can be applied in monitoring of oxygen availability and utilization by the brain in neonatal and adults, neuro- traumatology, intensive care medicine, transplantation and plastic surgery, in sport, high-altitude and aviation medicine.

  18. Categorization of Fetal Heart Rate Decelerations in American and European Practice: Importance and Imperative of Avoiding Framing and Confirmation Biases.

    Science.gov (United States)

    Sholapurkar, Shashikant L

    2015-09-01

    contractions alone irrespective of shape or descent time as indeed proposed by pioneers like Hon and Caldeyro-Barcia. Such meaningful categorization, apart from being a scientific necessity, could improve the practical performance of three-tier FHR interpretation systems and possibly application of dependent complementary techniques like fetal ECG/pulse oximetry/computer-aided analysis, thus facilitating future progress in the field of intrapartum fetal monitoring.

  19. Normative database of retinal oximetry in Asian Indian eyes.

    Directory of Open Access Journals (Sweden)

    Ashwin Mohan

    Full Text Available To study the oxygen saturation profile in normal Asian Indian eyes.A cross sectional prospective study.Ninety eight consecutive patients presenting to our hospital with best corrected distance visual acuity (BCVA of 20/20 and a normal ophthalmic examination were included in the study. Patients having any ocular or systemic disease were excluded from the study.Oximetry was performed on all subjects with the Oxymap T1 retinal oximeter (Oxymap hf, Reykjavik, Iceland.The images were analysed for oxygen saturation and diameter.The mean age was 33 years (Range: 18-63; SD: 12.4. The average arteriolar saturation was 90.3 ± 6.6% and the venous saturation was 56.9% ± 6.3. The average A-V (arterio-venous difference was 33.2% ± 5.2. There was an increase in arteriolar (R2 = 0.264; p=0.001 and venous saturation (R2 = 0.151; p=0.001 with age. There was no significant change in the arterio-venous saturation difference (AVSD. The inferotemporal quadrant had the lowest saturations. Age correlated positively with ocular perfusion pressure (OPP(R2 = 0.07; p=0.007. OPP correlated positively with global arteriolar saturation (R2=0.057, p=0.018.This study provides the normative database for an Indian population and is comparable to previous studies. Age, vessel diameter and OPP were the significant factors that influenced the saturation. Arteriolar and venous saturations increased with age while the AVSD did not change significantly.

  20. Fetal syringomyelia.

    Science.gov (United States)

    Guo, Anne; Chitayat, David; Blaser, Susan; Keating, Sarah; Shannon, Patrick

    2014-08-06

    We explored the prevalence of syringomyelia in a series of 113 cases of fetal dysraphism and hindbrain crowding, of gestational age ranging from 17.5 to 34 weeks with the vast majority less than 26 weeks gestational age. We found syringomyelia in 13 cases of Chiari II malformations, 5 cases of Omphalocele/Exostrophy/Imperforate anus/Spinal abnormality (OEIS), 2 cases of Meckel Gruber syndrome and in a single pair of pyopagus conjoined twins. Secondary injury was not uncommon, with vernicomyelia in Chiari malformations, infarct like histology, or old hemorrhage in 8 cases of syringomyelia. Vernicomyelia did not occur in the absence of syrinx formation. The syringes extended from the sites of dysraphism, in ascending or descending patterns. The syringes were usually in a major proportion anatomically distinct from a dilated or denuded central canal and tended to be dorsal and paramedian or median. We suggest that fetal syringomyelia in Chiari II malformation and other dysraphic states is often established prior to midgestation, has contributions from the primary malformation as well as from secondary in utero injury and is anatomically and pathophysiologically distinct from post natal syringomyelia secondary to hindbrain crowding.

  1. Medio ambiente fetal Fetal environment

    Directory of Open Access Journals (Sweden)

    César Bernardo Ospina Arcila

    1996-04-01

    Full Text Available Con base en el artículo clásico "Monte Everest in utero" se hace un análisis de la situación que afronta el feto con respecto a la disponibilidad de oxígeno; para una mejor comprensión del sufrimiento fetal se revisan los siguientes conceptos: presión barométrica, presión parcial del oxígeno atmosférico, presión parcial del oxígeno inspirado, presión barométrica intranasal, ecuación del gas alveolar y difusión de gases a través de la membrana alvéolo capilar. Based on the classical paper by Eastman "Mount Everest in utero" an analysis is made of the situation faced by the fetus with respect to the availability of oxygen; for a better under. standing of fetal distress the following concepts are reviewed: barometric pressure, partial pressure of atmosferic oxygen, partial pressure of inspired oxygen, barometric intranasal pressure, alveolar gas equation and gas diffusion through alveolo-capilar membrane.

  2. Clinical use of cerebral oximetry in extremely preterm infants is feasible

    DEFF Research Database (Denmark)

    Hyttel-Sørensen, Simon; Austin, Topun; van Bel, Frank

    2013-01-01

    The research programme Safeguarding the Brains of our smallest Children (SafeBoosC) aims to test the benefits and harms of cerebral near-infrared spectroscopy (NIRS) oximetry in infants born before 28 weeks of gestation. In a phase II trial, infants will be randomised to visible cerebral NIRS...

  3. Desaturation Patterns Detected by Oximetry in a Large Population of Athletes

    Science.gov (United States)

    Garrido-Chamorro, Raul P.; Gonzalez-Lorenzo, Marta; Sirvent-Belando, Jose; Blasco-Lafarga, Cristina; Roche, Enrique

    2009-01-01

    Optimal exercise performance in well trained athletes can be affected by arterial oxygen saturation failure. Noninvasive detection of this phenomenon when performing a routine ergometric test can be a valuable tool for subsequent planning of the athlete's training, recovery, and nutrition. Oximetry has been used to this end. The authors studied…

  4. Desaturation Patterns Detected by Oximetry in a Large Population of Athletes

    Science.gov (United States)

    Garrido-Chamorro, Raul P.; Gonzalez-Lorenzo, Marta; Sirvent-Belando, Jose; Blasco-Lafarga, Cristina; Roche, Enrique

    2009-01-01

    Optimal exercise performance in well trained athletes can be affected by arterial oxygen saturation failure. Noninvasive detection of this phenomenon when performing a routine ergometric test can be a valuable tool for subsequent planning of the athlete's training, recovery, and nutrition. Oximetry has been used to this end. The authors studied…

  5. Improvement of Infrared Detectors for Tissue Oximetry using Black Silicon Nanostructures

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Davidsen, Rasmus Schmidt; Alcala, Lucia R.;

    2014-01-01

    We present a nanostructured surface, made of dry etched black silicon, which lowers the reflectance for light incident at all angles. This surface is fabricated on infrared detectors used for tissue oximetry, where the detection of weak diffuse light signals is important. Monte Carlo simulations...

  6. Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry

    DEFF Research Database (Denmark)

    Clarkson, R B; Odintsov, B M; Ceroke, P J

    1998-01-01

    ; they can be calibrated and used for oximetry. Biological stability and low toxicity make chars good sensors for in vivo measurements. Scalar and dipolar interactions of water protons at the surfaces of chars may be utilized to produce dynamic nuclear polarization (DNP) of the nuclear spin population...

  7. Cost analysis of near-infrared spectroscopy tissue oximetry for monitoring autologous free tissue breast reconstruction.

    Science.gov (United States)

    Pelletier, Aaron; Tseng, Charles; Agarwal, Shailesh; Park, Julie; Song, David

    2011-10-01

    Free flap monitoring typically requires specialized nursing that can increase medical costs. This study uses near-infrared spectroscopy (NIRS) tissue oximetry to monitor free tissue breast reconstruction. We hypothesize this practice will reduce medical costs by eliminating the need for specialized nursing. From August 2006 to January 2010, women undergoing unilateral free tissue breast reconstruction were enrolled and admitted postoperatively to either the surgical intensive care unit (ICU) or floor. Each underwent continuous monitoring using NIRS tissue oximetry and intermittent clinical examination with surface Doppler ultrasonography. Patient demographics, comorbidities, perioperative details, and financial data were recorded. There were 50 patients studied, all with abdominal-based flaps (25 per group). There were no statistically significant differences in patient demographics, comorbidities, mean flap weight, ischemia time, or length of stay between the ICU and floor groups. Four flaps had vascular complications, all detected by NIRS tissue oximetry. Comparison of hospital costs showed an average reduction of $1937 per patient when monitored on the surgical floor (P = 0.036). NIRS tissue oximetry is a sensitive and reliable monitoring tool, eliminating the need for specialized nursing care. The effect is decreased cost structure and increased hospital contribution margin for autologous free tissue breast reconstruction.

  8. Fetal pain.

    Science.gov (United States)

    Rokyta, Richard

    2008-12-01

    The fetus reacts to nociceptive stimulations through different motor, autonomic, vegetative, hormonal, and metabolic changes relatively early in the gestation period. With respect to the fact that the modulatory system does not yet exist, the first reactions are purely reflexive and without connection to the type of stimulus. While the fetal nervous system is able to react through protective reflexes to potentially harmful stimuli, there is no accurate evidence concerning pain sensations in this early period. Cortical processes occur only after thalamocortical connections and pathways have been completed at the 26th gestational week. Harmful (painful) stimuli, especially in fetuses have an adverse effect on the development of humans regardless of the processes in brain. Moreover, pain activates a number of subcortical mechanisms and a wide spectrum of stress responses influence the maturation of thalamocortical pathways and other cortical activation which are very important in pain processing.

  9. Critical Congenital Heart Disease Screening by Pulse Oximetry in a Neonatal Intensive Care Unit

    Science.gov (United States)

    Manja, Veena; Mathew, Bobby; Carrion, Vivien; Lakshminrusimha, Satyan

    2014-01-01

    Critical congenital heart disease (CCHD) screening is effective in asymptomatic late preterm and term newborn infants with a low false positive rate (0.035%). Objective (1) To compare 2817 NICU discharges before and after implementation of CCHD screening; and (2) to evaluate CCHD screening at < 35 weeks gestation. Methods collection of results of CCHD screening including preductal and postductal SpO2 values. Results During the pre-CCHD screen period, 1247 infants were discharged from the NICU and one case of CCHD was missed. After 3/1/12, 1508 CCHD screens were performed among 1570 discharges and no CCHDs were missed. The preductal and postductal SpO2 values were 98.8±1.4% and 99±1.3% respectively in preterm and 98.9±1.3% and 98.9±1.4% in term infants. Ten infants had false positive screens (10/1508=0.66%). Conclusions Performing universal screening in the NICU is feasible but is associated with a higher false positive rate compared to asymptomatic newborn infants. PMID:25058746

  10. Design and implementation of a sigma delta technology based pulse oximeter's acquisition stage

    Science.gov (United States)

    Rossi, E. E.; Peñalva, A.; Schaumburg, F.

    2011-12-01

    Pulse oximetry is a widely used tool in medical practice for estimating patient's fraction of hemoglobin bonded to oxygen. Conventional oximetry presents limitations when changes in the baseline, or low amplitude of signals involved occur. The aim of this paper is to simultaneously solve these constraints and to simplify the circuitry needed, by using ΣΔ technology. For this purpose, a board for the acquisition of the needed signals was developed, together with a PC managed software which controls it, and displays and processes in real time the information acquired. Also laboratory and field tests where designed and executed to verify the performance of this equipment in adverse situations. A simple, robust and economic instrument was achieved, capable of obtaining signals even in situations where conventional oximetry fails.

  11. Fetal pain?

    Science.gov (United States)

    Vanhatalo, S; van Nieuwenhuizen, O

    2000-05-01

    During the last few years a vivid debate, both scientifically and emotionally, has risen in the medical literature as to whether a fetus is able to feel pain during abortion or intrauterine surgery. This debate has mainly been inspired by the demonstration of various hormonal or motor reactions to noxious stimuli at very early stages of fetal development. The aims of this paper are to review the literature on development of the pain system in the fetus, and to speculate about the relationship between "sensing" as opposed to "feeling" pain and the number of reactions associated with painful stimuli. While a cortical processing of pain theoretically becomes possible after development of the thalamo-cortical connections in the 26th week of gestation, noxious stimuli may trigger complex reflex reactions much earlier. However, more important than possible painfulness is the fact that the noxious stimuli, by triggering stress responses, most likely affect the development of an individual at very early stages. Hence, it is not reasonable to speculate on the possible emotional experiences of pain in fetuses or premature babies. A clinically relevant aim is rather to avoid and/or treat any possibly noxious stimuli, and thereby prevent their potential adverse effects on the subsequent development.

  12. Where do pulse oximeter probes break?

    Science.gov (United States)

    Crede, S; Van der Merwe, G; Hutchinson, J; Woods, D; Karlen, W; Lawn, J

    2014-06-01

    Pulse oximetry, a non-invasive method for accurate assessment of blood oxygen saturation (SPO2), is an important monitoring tool in health care facilities. However, it is often not available in many low-resource settings, due to expense, overly sophisticated design, a lack of organised procurement systems and inadequate medical device management and maintenance structures. Furthermore medical devices are often fragile and not designed to withstand the conditions of low-resource settings. In order to design a probe, better suited to the needs of health care facilities in low-resource settings this study aimed to document the site and nature of pulse oximeter probe breakages in a range of different probe designs in a low to middle income country. A retrospective review of job cards relating to the assessment and repair of damaged or faulty pulse oximeter probes was conducted at a medical device repair company based in Cape Town, South Africa, specializing in pulse oximeter probe repairs. 1,840 job cards relating to the assessment and repair of pulse oximeter probes were reviewed. 60.2 % of probes sent for assessment were finger-clip probes. For all probes, excluding the neonatal wrap probes, the most common point of failure was the probe wiring (>50 %). The neonatal wrap most commonly failed at the strap (51.5 %). The total cost for quoting on the broken pulse oximeter probes and for the subsequent repair of devices, excluding replacement components, amounted to an estimated ZAR 738,810 (USD $98,508). Improving the probe wiring would increase the life span of pulse oximeter probes. Increasing the life span of probes will make pulse oximetry more affordable and accessible. This is of high priority in low-resource settings where frequent repair or replacement of probes is unaffordable or impossible.

  13. Clinical relevance of fetal hemodynamic monitoring: Perinatal implications.

    Science.gov (United States)

    Pruetz, Jay D; Votava-Smith, Jodie; Miller, David A

    2015-08-01

    Comprehensive assessment of fetal wellbeing involves monitoring of fetal growth, placental function, central venous pressure, and cardiac function. Ultrasound evaluation of the fetus using 2D, color Doppler, and pulse-wave Doppler techniques form the foundation of antenatal diagnosis of structural anomalies, rhythm abnormalities and altered fetal circulation. Accurate and timely prenatal identification of the fetus at risk is critical for appropriate parental counseling, antenatal diagnostic testing, consideration for fetal intervention, perinatal planning, and coordination of postnatal care delivery. Fetal hemodynamic monitoring and serial assessment are vital to ensuring fetal wellbeing, particularly in the setting of complex congenital anomalies. A complete hemodynamic evaluation of the fetus gives important information on the likelihood of a smooth postnatal transition and contributes to ensuring the best possible outcome for the neonate.

  14. Challenge of Fetal Mortality

    Science.gov (United States)

    ... Reports from the National Medical Care Utilization and Expenditure Survey Clearinghouse on Health Indexes Statistical Notes for ... Fetal mortality is a major, but often overlooked, public health problem. Fetal mortality refers to spontaneous intrauterine ...

  15. A unique case of pulmonary artery catheter bleeding from the oximetry connection port

    Directory of Open Access Journals (Sweden)

    Suman Rajagopalan

    2014-12-01

    Full Text Available Pulmonary artery catheter is an invasive monitor usually placed in high-risk cardiac surgical patients to optimize the cardiac functions. We present this case of blood oozing from the oximetry connection port of the pulmonary artery catheter that resulted in the inability to monitor continuous cardiac output requiring replacement of the catheter. The cause of this abnormal bleeding was later confirmed to be due to a manufacturing defect.

  16. Transcutaneous oximetry monitoring in patients with type 2 diabetes mellitus and critical limb ischemia

    Directory of Open Access Journals (Sweden)

    O N Bondarenko

    2013-03-01

    Full Text Available Aims. To evaluate transcutaneous oximetry as a method for diagnostics and monitoring in patients with diabetes mellitus (DM and critical limb ischemia (CLI after percutaneous transluminal balloon angioplasty (PTBA.Materials and Methods. We enrolled 126 patients with DM and CLI for participation in this study (148 limbs in total. 22 patients underwent PTBA on both lower limbs, and 104 – on single limb. Transcutaneous oximetry and duplex ultrasonography of lower limb arteries was performed prior to PTBA with subsequent examinations on 5-7th days, 1st, 3rd and 6th month after intervention. Transcu- taneous oxygen tension (TcpO2 was measured by Radiometer (Copenhagen oximeter system. Duplex ultrasonography was performed on Voluson 730® Expert system (GE Medical Systems Kretztechnik GmbH&Co OHG, Austria.Results. Multiple factor analysis suggests that results of TcpO2 monitoring prior to and after PTBA are influenced by presence of ischemic heart disease, severe lower limb infections, serum creatinine, arterial hypertension and lower limb reperfusion edema. We observed a strong correlation of TcpO2 with the degree of anterior tibial artery and dorsal pedis artery occlusion.Conclusion. Transcutaneous oximetry allows evaluation of CLI severity and efficiency of PTBA in the majority oа patients with DM and CLI. Certain comorbidities impose limitations on this technique. Efficiency of endovascular intervention should be evaluated based on complex non-invasive examination, clinical data and signs of CLI.

  17. Evaluation of cerebral oximetry during endovascular treatment of carotid-cavernous fistula

    Science.gov (United States)

    Dujovny, Manuel; Misra, Mukesh; Alp, M. Serdar; Debrun, Gerard; Charbel, F. T.; Aletich, Victor; Ausman, James I.

    1997-08-01

    Endovascular treatment of carotid cavernous fistula is done routinely in our institution. We have been monitoring these patients with transcranial cerebral oximetry. The transcranial cerebral oximeter is a reliable, low-cost, non-invasive device that provides real-time evaluation of regional brain oxygen saturation during and after endovascular treatment of cerebrovascular diseases. We used the INVOS 3100A (Somanetics, Troy, MI) in our study. We discuss seven patients with carotid-cavernous fistulas treated by endovascular balloon occlusion, each monitored continuously before, during, and after the procedure with transcranial cerebral oximetry. The cerebral oxygen saturation depicted was directly related to the side of the venous drainage of the fistula, with the brain oxygen saturation 15 - 20% higher on the side of the venous drainage. Following endovascular occlusion of the fistula, oxygen saturation gradually became equal on both sides. In our patients treated for carotid-cavernous fistula, we evaluated the sensitivity and usefulness of cerebral oximetry as an important non-invasive monitoring tool for the endovascular treatment of carotid-cavernous fistula.

  18. Fetal behavioral teratology

    NARCIS (Netherlands)

    Visser, Gerard H. A.; Mulder, Eduard J. H.; Ververs, F. F. Tessa

    2010-01-01

    Ultrasound studies of fetal motor behavior provide direct - in vivo - insight in the functioning of the motor component of the fetal central nervous system. In this article, studies are reviewed showing changes in the first timetable of appearance of fetal movements, changes in quality and/or quanti

  19. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality...... a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, an anthropomorfized archive of a past intimacy and an all-encompassing immersive environment modulating continuously in real space-time....

  20. A confocal scanning laser ophthalmoscope for retinal vessel oximetry

    Science.gov (United States)

    Lompado, Arthur

    Measurement of a person's blood oxygen saturation has long been recognized as a useful metric for the characterizing ailments ranging from chronic respiratory disorders to acute, potentially life threatening, traumas. The ubiquity of oxygen saturation monitors in the medical field, including portable pulse oximeters and laboratory based CO-oximeters, is a testament to the importance of this technique. The work presented here documents the design, fabrication and development of a unique type of oxygen saturation monitor, a confocal scanning retinal vessel oximeter, with the potential to expand the usefulness of the present devices. A large part of the knowledge base required to construct the instrument comes from the consideration of light scattering by red blood cells in a blood vessel. Therefore, a substantial portion of this work is devoted to the process of light scattering by whole human blood and its effects on the development of a more accurate oximeter. This light scattering effect has been both measured and modeled stochastically to determine its contribution to the measured oximeter signal. It is shown that, although well accepted in the published literature, the model only correlates marginally to the measurements due to inherent limitations imposed by the model assumptions. Nonetheless, enough material has been learned about the scattering to allow development of a mathematical model for the interaction of light with blood in a vessel, and this knowledge has been applied to the data reduction of the present oximeter. This data reduction technique has been tested in a controlled experiment employing a model eye with a blood filled mock retinal vessel. It will be shown that the presently developed technique exhibited strong correlation between the known blood oxygen saturation and that calculated by the new system.

  1. Using India Ink as a Sensor for Oximetry: Evidence of its Safety as a Medical Device.

    Science.gov (United States)

    Flood, Ann Barry; Wood, Victoria A; Swartz, Harold M

    2017-01-01

    Clinical EPR spectroscopy is emerging as an important modality, with the potential to be used in standard clinical practice to determine the extent of hypoxia in tissues and whether hypoxic tissues respond to breathing enriched oxygen during therapy. Oximetry can provide important information useful for prognosis and to improve patient outcomes. EPR oximetry has many potential advantages over other ways to measure oxygen in tissues, including directly measuring oxygen in tissues and being particularly sensitive to low oxygen, repeatable, and non-invasive after an initial injection of the EPR-sensing material is placed in the tumor. The most immediately available oxygen sensor is India ink, where two classes of carbon (carbon black and charcoal) have been identified as having acceptable paramagnetic properties for oximetry. While India ink has a long history of safe use in tattoos, a systematic research search regarding its safety for marking tissues for medical uses and an examination of the evidence that differentiates between ink based on charcoal or carbon black has not been conducted. Using systematic literature search techniques, we searched the PubMed and Food and Drug Administration databases, finding ~1000 publications reporting on adverse events associated with India/carbon based inks. The detailed review of outcomes was based on studies involving >16 patients, where the ink was identifiable as carbon black or charcoal. Fifty-six studies met these criteria. There were few reports of complications other than transient and usually mild discomfort and bleeding at injection, and there was no difference in charcoal vs. carbon black India ink. India ink was generally well tolerated by patients and physicians reported that it was easy to use in practice and used few resources. The risk is low enough to justify its use as an oxygen sensor in clinical practice.

  2. Fetal Health and Development

    Science.gov (United States)

    ... specific prenatal tests to monitor both the mother's health and fetal health during each trimester. With modern technology, health professionals can Detect birth defects Identify problems that ...

  3. ASCITIS FETAL AISLADA

    OpenAIRE

    2003-01-01

    La ascitis fetal aislada es una entidad asociada a múltiples patologías, el diagnostico se realiza usualmente cuando fueron descartados las otras causas de ascitis fetal. Se describe el diagnóstico prenatal de un paciente con ascitis fetal aislada compatible con atresia ileal y peritonitis meconial secundaria a perforación de ileon distal. La ascitis fetal se resolvió posterior a la cirugía al segundo día de vida. Este caso tiene un buen pronostico debido al control tanto prenatal como intra ...

  4. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality......“Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... of the visitor’s beating heart to the blink of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the blinking light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant...

  5. Accounting for Fetal Origins

    DEFF Research Database (Denmark)

    Dalgaard, Carl-Johan Lars; Hansen, Casper Worm; Strulik, Holger

    2017-01-01

    The Fetal Origins hypothesis has received considerable empirical support, both within epidemiology and economics. The present study compares the ability of two rival theoretical frameworks in accounting for the kind of path dependence implied by the Fetal Origins Hypothesis. We argue that while...

  6. Fetal Alcohol Spectrum Disorder

    Science.gov (United States)

    Caley, Linda M.; Kramer, Charlotte; Robinson, Luther K.

    2005-01-01

    Fetal alcohol spectrum disorder (FASD) is a serious and widespread problem in this country. Positioned within the community with links to children, families, and healthcare systems, school nurses are a critical element in the prevention and treatment of those affected by fetal alcohol spectrum disorder. Although most school nurses are familiar…

  7. Fetal scalp pH testing

    Science.gov (United States)

    Fetal scalp blood; Scalp pH testing; Fetal blood testing - scalp; Fetal distress - fetal scalp testing; Labor - fetal scalp testing ... a baby. In these cases, testing the scalp pH can help the doctor decide whether the fetus ...

  8. Visualization of oxygen transportation in microcirculation by sidestream dark-field oximetry

    Science.gov (United States)

    Kurata, Tomohiro; Takahashi, Minori; Oda, Shigeto; Kawahira, Hiroshi; Ohnishi, Takashi; Haneishi, Hideaki

    2017-02-01

    The sidestream dark-field (SDF) imaging allows direct visualization of red blood cells in microvessels near tissue surfaces. We have developed an image-based oximetry method using two-band images obtained by SDF imaging (SDF oximetry) and a trial SDF device with light-emitting diodes to obtain band images. In this study, we propose a technique of producing oxygen saturation (SO2) maps from SDF images and perform animal experiments in vivo. To produce SO2 maps, we use spectral analysis using two band images obtained with our SDF device. As an image processing, the combination of both the Hessian-based and pixel value-based techniques as blood vessel extraction from an SDF image is used. From the experiment with the surface of rat small intestines, we can produce SO2 maps and find that the map represents arterioles and venules those were determined based on the blood ow from SDF images. Moreover, we find the variation of SO2 along a blood vessel running direction.

  9. Hydroxocobalamin and cyanocobalamin interference on co-oximetry based hemoglobin measurements.

    Science.gov (United States)

    Pamidi, Prasad V A; DeAbreu, Marlene; Kim, Donghak; Mansouri, Sohrab

    2009-03-01

    Hydroxocobalamin (OHCbl) and cyanocobalamin (CNCbl) are dark-red colored analogs of vitamin B-12. OHCbl is used as an alternate antidote for cyanide poisoning. Due to the strong red color, if uncorrected, these cobalamins interfere with hemoglobin measurements and can introduce errors in spectrophotometric assay on co-oximeters. The impact of cobalamins on commonly used co-oximetry systems was compared to evaluate the accuracy of hemoglobin measurements and to further assess the ability of the instruments to detect and flag cobalamin interference. Blood samples spiked with varying concentrations of hydroxocobalamin or cyanocobalamin (0-2 g/l), were measured on 3 GEM Premier 4000 s, 3 IL 682 CO-Oximeter, 1 Radiometer ABL 735 and 1 Siemens Rapidpoint 405 analyzer. The effect of OHCbl or CNCbl interference on total hemoglobin and hemoglobin derivatives is evaluated using the measured difference between the control sample and the spiked sample. Spectral measurements, blood measurements and delta spectral data confirmed that hemoglobin measurement accuracy is affected by the presence of OHCbl or CNCbl and that the source of interference is from errors in measurement algorithms, and not due to cobalamin induced hemoglobin changes. Among the 4 co-oximeters tested in this evaluation, GEM Premier 4000 and Rapidpoint 405 analyzer showed minimal impact for hydroxocobalamin concentrations around 0.5 g/l. Cyanocobalamin displayed similar interference effect on co-oximetry measurements as OHCbl. The error detection system in the GEM Premier 4000 appropriately detected and flagged interferences on sample measurements.

  10. TELEMOLD project: oximetry and exercise telemonitoring to improve long-term oxygen therapy.

    Science.gov (United States)

    Faria, Inês; Gaspar, Carina; Zamith, Manuela; Matias, Isabel; das Neves, Rui César; Rodrigues, Fátima; Bárbara, Cristina

    2014-07-01

    Standard assessment of long-term oxygen therapy (LTOT) prescription involves hospital-based clinical tests. However, there is some evidence suggesting that oxygen demand during daily activities may not be correctly estimated by such tests, when compared with continuous ambulatory oximetry. The authors describe the results of a study aiming to evaluate the clinical relevance of a home telemonitoring system in LTOT optimization. Thirty-five chronic respiratory failure patients were monitored in real time with an oximeter sensor and an accelerometer. Signals were sent via Bluetooth(®) (Bluetooth SIG, Kirkland, WA) to a mobile phone and then via 3G or general packet radio service to a server. Continuous and secure access to data was established through an Internet site. Each patient was monitored an average of 7.6 ± 4.5 days (total, 83 ± 67 h). Valid records were on average 65 ± 24%. Records of rest, activity, and sleep time per patient were, on average, 28 ± 21%, 7 ± 6%, and 59 ± 25%, respectively. Significant desaturation during rest, activity, and sleep was found in 2, 26, and 9 patients, respectively. Patients' ratings of the user-friendliness of the equipments, assessed by questionnaire, were fairly good (76% reported it as easy/very easy). Our study suggests that a telemonitoring system combining oximetry and physical activity evaluation might contribute to a more adequate oxygen prescription, mainly during daily activities.

  11. A paramagnetic implant containing lithium naphthalocyanine microcrystals for high-resolution biological oximetry.

    Science.gov (United States)

    Meenakshisundaram, Guruguhan; Pandian, Ramasamy P; Eteshola, Edward; Lee, Stephen C; Kuppusamy, Periannan

    2010-03-01

    Lithium naphthalocyanine (LiNc) is a microcrystalline EPR oximetry probe with high sensitivity to oxygen [R.P. Pandian, M. Dolgos, C. Marginean, P.M. Woodward, P.C. Hammel, P.T. Manoharan, P. Kuppusamy, Molecular packing and magnetic properties of lithium naphthalocyanine crystal: hollow channels enabling permeability and paramagnetic sensitivity to molecular oxygen J. Mater. Chem. 19 (2009) 4138-4147]. However, direct implantation of the crystals in the tissue for in vivo oxygen measurements may be hindered by concerns associated with their direct contact with the tissue/cells and loss of EPR signal due to particle migration in the tissue. In order to address these concerns, we have developed encapsulations (chips) of LiNc microcrystals in polydimethyl siloxane (PDMS), an oxygen-permeable, bioinert polymer. Oximetry evaluation of the fabricated chips revealed that the oxygen sensitivity of the crystals was unaffected by encapsulation in PDMS. Chips were stable against sterilization procedures or treatment with common biological oxidoreductants. In vivo oxygen measurements established the ability of the chips to provide reliable and repeated measurements of tissue oxygenation. This study establishes PDMS-encapsulated LiNc as a potential probe for long-term and repeated measurements of tissue oxygenation. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  12. Cerebral oximetry and cerebral blood flow monitoring in 2 pediatric survivors with out-of-hospital cardiac arrest.

    Science.gov (United States)

    Abramo, Thomas; Aggarwal, Nitin; Kane, Ian; Crossman, Kristen; Meredith, Mark

    2014-04-01

    In pediatric out-of-hospital cardiac arrest (POHCA), cardiovascular monitoring tools have improved resuscitative endeavors and cardiovascular outcomes but with still poor neurologic outcomes. Regarding cardiac arrest in patients with congenital heart disease during surgery, the application of cerebral oximetry with blood volume index (BVI) during the resuscitation has shown significant results and prognostic significance. We present 2 POHCA patients who had cerebral oximetry with BVI monitoring during their arrest and postarrest phase in the emergency department and its potential prognostic aspect.Basic procedures include left and right cerebral oximetry with BVI monitoring at every 5-second interval during cardiac arrest, resuscitation, and postarrest in 2 POHCA patients in the pediatric emergency department.Regional cerebral tissue oxygen saturation (rSo2) with BVI readings in these 2 POHCA survivors demonstrated interesting cerebral physiology, blood flow, and potential prognostic outcome. In 1 patient, the reference range of cerebral rSo2 with positive blood flow during arrest and postarrest phases consistently occurred. This neurologic monitoring had its significance when the resuscitation effectiveness was used and end-tidal CO2 changes were lost. The other patient's cerebral rSo2 with simultaneous BVI readings and trending showed the effectiveness of the emergency medical services (EMS) resuscitation.Cerebral oximetry with cerebral blood flow index monitoring in these POHCA survivors demonstrates compelling periarrest and postarrest cerebral physiology information and prognostication. Cerebral oximetry with cerebral BVI monitoring during these arrest phases has potential as a neurologic monitor for the resuscitative intervention's effectiveness and its possible neurologic prognostic application in the pediatric OCHA patients.

  13. EFFECT OF DIGITAL BLOCK ON SPAO2, LAG TIME AND HEIGHT OF PLETHYSMOGRAPHIC WAYE OF PULSE OXIMETER BY SIMULATED SHOCK

    Directory of Open Access Journals (Sweden)

    K TAVAKKOL

    2002-06-01

    Full Text Available Introduction. Pulse oximetry is impaired by hypotention and peripheral vasoconstriction. Digital block may cause to increase tissue perfusion and improve the parameters of pulse oximetry. The purpose of this study was to investigate the effect of digital block on SPa02, lag time and height of plethysmographic wave of pulse oximeter by simulated shock in upper extrimity. Methods. In an experimental study, 34 Paitents under general anesthesia and elective surgery were selected. Lag time and height of pletysmographic wave and SPa02 had been measured in two fingers shocked by cooling, elevation of hand and inflation of cuff; then, compared to opposite middle finger as control. shocked Middle finger were blocked by lidocaine 2% and these parameters were measured in the 15th and 20th minutes after digital block. Data analysis was performed by SPSS using ANOVA. Results. Mean height of plethysmographic wave in blocked finger was signihcontly taller than shocked and control fingers in the 15th minute (respectively, 16.9±6, 10.8 ± 4. 3,10.7 ± 4.3, P < 0.05 and the 20th minute afters digital block (21.1 ± 5.8, 11.8 ± 4.3, 11.2 ± 3.9, P < 0.05. There were not significalt differences between three fingers in lag time and SPa02. Discussion. This study documents effect of digital block, undergoing shock condition in improving the parameters of pulse oximetry.

  14. Fetal and neonatal thyrotoxicosis

    Directory of Open Access Journals (Sweden)

    Chandar Mohan Batra

    2013-01-01

    Full Text Available Fetal thyrotoxicosis is a rare disease occurring in 1 out of 70 pregnancies with Grave′s disease or in 1 out of 4000-50,000 deliveries. The mortality is 12-20%, usually from heart failure, but other complications are tracheal compression, infections and thrombocytopenia. It results from transfer of thyroid stimulating immunoglobulins from mother to fetus through the placenta. This transplacental transfer begins around 20 th week of pregnancy and reaches its maximum by 30 th week. These autoantibodies bind to the fetal thyroid stimulating hormone (TSH receptors and increase the secretion of the thyroid hormones. The mother has an active autoimmune thyroid disease or has been treated for it in the past. She may be absolutely euthyroid due to past treatment by drugs, surgery or radioiodine ablation, but still have active TSH receptor stimulating autoantibodies, which can cause fetal thyrotoxicosis. The other features of this disease are fetal tachycardia, fetal goiter and history of spontaneous abortions and findings of goiter, ascites, craniosyntosis, fetal growth retardation, maceration and hydrops at fetal autopsy. If untreated, this disease can result in intrauterine death. The treatment for this disease consists of giving carbimazole to the mother, which is transferred through the placenta to the fetus. The dose of carbimazole is titrated with the fetal heart rate. If the mother becomes hypothyroid due to carbimazole, thyroxine is added taking advantage of the fact that very little of thyroxine is transferred across the placenta. Neonatal thyrotoxicosis patients are very sick and require emergency treatment. The goal of the treatment is to normalize thyroid functions as quickly as possible, to avoid iatrogenic hypothyroidism while providing management and supportive therapy for the infant′s specific signs and symptoms.

  15. The evaluation of cerebral oxygenation by oximetry in patients with ischaemic stroke.

    Directory of Open Access Journals (Sweden)

    Demet G

    2000-04-01

    Full Text Available AIMS: To evaluate the clinical significance of estimation of the regional cerebral oxygen saturation (rSO2 in the patients with ischaemic stroke by the cerebral oximetry during acute, sub-acute and chronic phases. SUBJECTS AND METHODS: In this prospective study, 24 patients with ischaemic stroke in the middle cerebral artery territory were included. A detailed clinical examination and appropriate laboratory investigations were carried out. The rSO2 was determined by oximetery (INVOS 3100-SD bilaterally on the first, third, seventh, and fifteenth days. The blood pressure, the peripheral capillary oxygen saturation and the arterial blood gas values were noted too. the changes were evaluated along with Glasgow coma scale (GCS using unpaired student t-test and one way ANOVA test. RESULTS: There were significant differences between the rSO2 values in acute, subacute and chronic phases on the side of the lesion (p value < 0.05. The values of oxygen saturation gradually increased throughout the chronic phase. These values showed a positive correlation with GCS, but the results were not significant statistically. The rSO2 values were also significantly higher on the non-lesional side than those on the lesion side in the acute phase (p= 0.0034, the discrepancy disappeared during the sub-acute and chronic phases. CONCLUSION: Cerebral oximetry can be used as a measure to evaluate the cerebral oxygenation during the various phases of ischaemic stroke. It has a potential to serve as a useful marker for detection of cerebral oxygenation imbalances, to judge the effectiveness of the management and for the follow-up of patients with ischaemic stroke.

  16. Magnesium and fetal growth

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, K.

    1988-01-01

    Fetal growth retardation and premature labor are major problems in perinatal medicine today and account for a great deal of the observed fetal morbidity. While the neonatal death rate has steadily declined over the past decade, there has been a lack of concommitant decrease in these two leading problems. Magnesium (Mg/sup ++/) plays a major role in both of these areas of concern. The fact that it is used as a treatment for premature labor has led investigators to look at low Mg/sup ++/ as a possible cause of this poorly understood phenomenon. The second major cause of small for gestational age infants is intrauterine growth retardation, a condition which may be of either fetal or maternal origin. In either case, Mg/sup ++/ may be implicated since it exerts a strong influence on the underlying pathophysiology of placental failure and maternal hypertension. Both of these conditions are mediated by vascular and platelet hyperactivity as well as by and increase in the ration of thromboxane to prostacyclin. Studies in both the human and animal species are beginning to show how Mg/sup ++/ interacts in these conditions to produce such a damaging fetal outcome. The recent use of Doppler velocimetry of the developing fetus has shown reduced fetal vascular and maternal uterine vascular compliance as early as 14 weeks of gestation in those who would be so affected.

  17. Fetal Biophysical Profile Scoring

    Directory of Open Access Journals (Sweden)

    H.R. HaghighatKhah

    2009-01-01

    Full Text Available   "nFetal biophysical profile scoring is a sonographic-based method of fetal assessment first described by Manning and Platt in 1980. "nThe biophysical profile score was developed as a method to integrate real-time observations of the fetus and his/her intrauterine environment in order to more comprehensively assess the fetal condition. These findings must be evaluated in the context of maternal/fetal history (i.e., chronic hypertension, post-dates, intrauterine growth restriction, etc, fetal structural integrity (presence or absence of congenital anomalies, and the functionality of fetal support structures (placental and umbilical cord. For example, acute asphyxia due to placental abruption may result in an absence of the acute variables of the biophysical profile score (fetal breathing movements, fetal movement, fetal tone, and fetal heart rate reactivity with a normal amniotic fluid volume. With post maturity the asphyxial event may be intermittent and chronic resulting in a decrease in amniotic fluid volume, but with the acute variables remaining normal. "nWhile the 5 components of the biophysical profile score have remained unchanged since 1980 (Manning, 1980, the definitions of a normal and abnormal parameter have evolved with increasing experience. "nIn 1984 the definition of oligohydramnios was increased from < 1cm pocket of fluid to < 2.0 x 1.0 cm pocket. Oligohydramnios is now defined as a pocket of amniotic fluid < 2.0 x 2.0 cm (Manning, 1995a "nIf the four ultrasound variables are normal, the accuracy of the biophysical profile score was not found to be significantly improved by adding the non-stress test. As a result, in 1987 the profile score was modified to incorporate the non-stress test only when one of the ultrasound variables was abnormal (Manning 1987. Table 1 outlines the current definitions for quantifying a variable as present or absent. "nEach of the 5 components of the biophysical profile score does not have equal

  18. A Comparison of Pulse-Oximetry, Near-Infrared Spectroscopy (NIRS), and Gas Sensors for In-Cockpit Hypoxia Detection

    Science.gov (United States)

    2012-08-29

    conditions that would preclude them from participating in a hypoxia experiment, including: a previous or current diagnosis of anemia , asthma, heart...enrolled, or reported being claustrophobic. Female subjects were given a urine pregnancy test and excluded if they tested positive for human

  19. Blood gases and oximetry: calibration-free new dry-chemistry and optical technology for near-patient testing.

    Science.gov (United States)

    Boalth, N; Wandrup, J; Larsson, L; Frischauf, P A; Lundsgaard, F C; Andersen, W L; Jensen, N; Singer, R; Troldborg, C P; Lunding, G

    2001-05-01

    The first calibration-free Near-Patient-Testing instrument (NPT7) for blood gases, pH and oximetry has been developed. With cartridges of 30 single-use cuvettes, the NPT7 needs no preparation prior to sample aspiration, no manual calibration, and no maintenance apart from paper and cartridge changes and regulatory quality control. Each cuvette measures pCO2, pO2, pH, total hemoglobin (ctHb), oxygen saturation (sO2), fractions of carboxyhemoglobin (FCOHb) and methemoglobin (FMetHb) on 95 microl whole blood with a 110-s measuring cycle. The measurement principles are as follows: pCO2-three-wavelength infrared spectroscopy of dissolved CO2; pO2-measurement of O2-induced changes in the decay time of phosphorescence; pH-the absorbance spectra change of an azo-dye color indicator; and oximetry is performed with a 128-wavelength spectrophotometer. We determined the within and between instrument variations with tonometered whole blood on seven prototype instruments, using between one and five control levels per analyte. The 95% analytical performance limits: +/-(/Bias/ +2 xS(T)) in the NPT7 instrument matched the analytical performance criteria for the measured quantities as defined by AACC guidelines. The application of these optical measuring methods for blood gases, pH and oximetry in single-use devices introduces a new concept into point-of-care testing (POCT), where preanalytical activities otherwise associated with instrument preparation are eliminated.

  20. Plasticity of fetal cartilaginous cells

    OpenAIRE

    Quintin, Aurelie; Schizas, Constantin; Scaletta, Corinne; Jaccoud, Sandra; Applegate, Lee Ann; Pioletti, Dominique P.

    2010-01-01

    Tissue-specific stem cells found in adult tissues can participate to the repair process following injury. However adult tissues, such as articular cartilage and intervertebral disc, have low regeneration capacity, whereas fetal tissues, such as articular cartilage, show high regeneration ability. The presence of fetal stem cells in fetal cartilaginous tissues and their involvement in the regeneration of fetal cartilage is unknown. The aim of the study was to assess the chondrogenic differenti...

  1. Fetal fluid and protein dynamics

    NARCIS (Netherlands)

    Pasman, Suzanne

    2010-01-01

    In this thesis fetal fluid and protein dynamics are investigated to gain insight in fetal (patho-)physiology. Studies were performed in fetuses with severe anemia and/or hydrops fetalis. Measurements were performed in fetal blood or amniotic fluid, obtained before or during intrauterine transfusion.

  2. [Accuracy of a pulse oximeter during hypoxia].

    Science.gov (United States)

    Tachibana, C; Fukada, T; Hasegawa, R; Satoh, K; Furuya, Y; Ohe, Y

    1996-04-01

    The accuracy of the pulse oximeter was examined in hypoxic patients. We studied 11 cyanotic congenital heart disease patients during surgery, and compared the arterial oxygen saturation determined by both the simultaneous blood gas analysis (CIBA-CORNING 288 BLOOD GAS SYSTEM, SaO2) and by the pulse oximeter (DATEX SATELITE, with finger probe, SpO2). Ninty sets of data on SpO2 and SaO2 were obtained. The bias (SpO2-SaO2) was 1.7 +/- 6.9 (mean +/- SD) %. In cyanotic congenital heart disease patients, SpO2 values were significantly higher than SaO2. Although the reason is unknown, in constantly hypoxic patients, SpO2 values are possibly over-estimated. In particular, pulse oximetry at low levels of saturation (SaO2 below 80%) was not as accurate as at a higher saturation level (SaO2 over 80%). There was a positive correlation between SpO2 and SaO2 (linear regression analysis yields the equation y = 0.68x + 26.0, r = 0.93). In conclusion, the pulse oximeter is useful to monitor oxygen saturation in constantly hypoxic patients, but the values thus obtained should be compared with the values measured directly when hypoxemia is severe.

  3. In vivo evidence of methamphetamine induced attenuation of brain tissue oxygenation as measured by EPR oximetry

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, John, E-mail: jmweaver@salud.unm.edu [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Yang, Yirong [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Purvis, Rebecca [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Neurology, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Weatherwax, Theodore [Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Rosen, Gerald M. [Center for Biomedical Engineering and Technology, University of Maryland, Baltimore, MD 21201 (United States); Center for EPR Imaging In Vivo Physiology, University of Maryland, Baltimore, MD 21201 (United States); Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD 21201 (United States); Liu, Ke Jian [Center of Biomedical Research Excellence, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Pharmaceutical Sciences, College of Pharmacy, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States); Department of Neurology, University of New Mexico Health Sciences Center, Albuquerque, NM 87131 (United States)

    2014-03-01

    Abuse of methamphetamine (METH) is a major and significant societal problem in the US, as a number of studies have suggested that METH is associated with increased cerebrovascular events, hemorrhage or vasospasm. Although cellular and molecular mechanisms involved in METH-induced toxicity are not completely understood, changes in brain O{sub 2} may play an important role and contribute to METH-induced neurotoxicity including dopaminergic receptor degradation. Given that O{sub 2} is the terminal electron acceptor for many enzymes that are important in brain function, the impact of METH on brain tissue pO{sub 2}in vivo remains largely uncharacterized. This study investigated striatal tissue pO{sub 2} changes in male C57BL/6 mice (16–20 g) following METH administration using EPR oximetry, a highly sensitive modality to measure pO{sub 2}in vivo, in situ and in real time. We demonstrate that 20 min after a single injection of METH (8 mg/kg i.v.), the striatal pO{sub 2} was reduced to 81% of the pretreatment level and exposure to METH for 3 consecutive days further attenuated striatal pO{sub 2} to 64%. More importantly, pO{sub 2} did not recover fully to control levels even 24 h after administration of a single dose of METH and continual exposure to METH exacerbates the condition. We also show a reduction in cerebral blood flow associated with a decreased brain pO{sub 2} indicating an ischemic condition. Our findings suggests that administration of METH can attenuate brain tissue pO{sub 2}, which may lead to hypoxic insult, thus a risk factor for METH-induced brain injury and the development of stroke in young adults. - Highlights: • Explored striatal tissue pO{sub 2}in vivo after METH administration by EPR oximetry. • pO{sub 2} was reduced by 81% after a single dose and 64% after 3 consecutive daily doses. • pO{sub 2} did not recover fully to control levels even 24 h after a single dose. • Decrease in brain tissue pO{sub 2} may be associated with a decrease in

  4. Cerebral Oximetry in Ugandan Children With Severe Anemia: Clinical Categories and Response to Transfusion.

    Science.gov (United States)

    Dhabangi, Aggrey; Ainomugisha, Brenda; Cserti-Gazdewich, Christine; Ddungu, Henry; Kyeyune, Dorothy; Musisi, Ezra; Opoka, Robert; Stowell, Christopher P; Dzik, Walter H

    2016-10-01

    Severe anemia, defined as a hemoglobin level of less than 5.0 g/dL, affects millions of children worldwide. The brain has a high basal demand for oxygen and is especially vulnerable to hypoxemia. Previous studies have documented neurocognitive impairment in children with severe anemia. Data on cerebral tissue oxygenation in children with severe anemia and their response to blood transfusion are limited. To measure hemoglobin saturation in cerebral tissue (cerebral tissue oxygen saturation [tSo2]) before, during, and after blood transfusion in a cohort of children presenting to hospital with severe anemia. This was a prospective, observational cohort study conducted from February 2013 through May 2015 and analyzed in July 2015 at a university hospital pediatric acute care facility in Kampala, Uganda, of 128 children, ages 6 to 60 months who were enrolled in a larger clinical trial, with a presenting hemoglobin level of less than 5.0 g/dL and a blood lactate level greater than 5mM. Most children had either malaria or sickle cell disease. Red blood cell (RBC) transfusion given as 10 mL/kg over 120 minutes. Clinical and laboratory characteristics of children with pretransfusion cerebral tSo2 levels less than 65%, 65% to 75%, and greater than 75%. Change in cerebral tSo2 as a result of transfusion. Of 128 children included in the study, oximetry results in 8 cases were excluded owing to motion artifacts; thus, 120 were included in this analysis. Cerebral tSo2 values prior to transfusion ranged from 34% to 87% (median, 72%; interquartile range [IQR], 65%-76%). Eighty-one children (67%) demonstrated an initial cerebral tSo2 level (≤75%) corresponding to an oxygen extraction ratio greater than 0.36. Patients with sickle cell disease (n = 17) and malaria (n = 15) contributed in nearly equal numbers to the subgroup with an initial cerebral tSo2 (children failed to achieve a tSo2 level greater than 75%. Severe anemia in children is frequently associated with low

  5. Micronutrients and fetal growth.

    Science.gov (United States)

    Fall, Caroline H D; Yajnik, Chittaranjan S; Rao, Shobha; Davies, Anna A; Brown, Nick; Farrant, Hannah J W

    2003-05-01

    Fetal undernutrition affects large numbers of infants in developing countries, with adverse consequences for their immediate survival and lifelong health. It manifests as intrauterine growth retardation (IUGR), defined as birth weight fetus is nourished by a complex supply line that includes the mother's diet and absorption, endocrine status and metabolism, cardiovascular adaptations to pregnancy and placental function. Micronutrients are essential for growth, and maternal micronutrient deficiency, frequently multiple in developing countries, may be an important cause of IUGR. Supplementation of undernourished mothers with micronutrients has several benefits but there is little hard evidence of improved fetal growth. However, this has been inadequately tested. Most trials have only used single micronutrients and many were inconclusive because of methodological problems. Several food-based studies (some uncontrolled) suggest benefits from improving maternal dietary quality with micronutrient-dense foods. One trial of a multivitamin supplement (HIV-positive mothers, Tanzania) showed increased birth weight and fewer fetal deaths. Well-conducted randomized controlled trials of adequate sample size and including measures of effectiveness are needed in populations at high risk of micronutrient deficiency and IUGR and should include food-based interventions and better measurements of fetal growth, maternal metabolism, and long-term outcomes in the offspring.

  6. MRI of the Fetal Brain.

    Science.gov (United States)

    Weisstanner, C; Kasprian, G; Gruber, G M; Brugger, P C; Prayer, D

    2015-10-01

    The purpose of this article is to provide an overview of the possibilities for fetal magnetic resonance imaging (MRI) in the evaluation of the fetal brain. For brain pathologies, fetal MRI is usually performed when an abnormality is detected by previous prenatal ultrasound, and is, therefore, an important adjunct to ultrasound. The most commonly suspected brain pathologies referred to fetal MRI for further evaluation are ventriculomegaly, missing corpus callosum, and abnormalities of the posterior fossa. We will briefly discuss the most common indications for fetal brain MRI, as well as recent advances.

  7. Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering

    Energy Technology Data Exchange (ETDEWEB)

    Yamamura, Jin; Frisch, Michael; Ecker, Hannes; Adam, Gerhard; Wedegaertner, Ulrike [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Graessner, Joachim [Siemens AG, Healthcare, Hamburg (Germany); Hecher, Kurt [University Medical Center Hamburg-Eppendorf, Department of Obstetrics and Fetal Medicine, Hamburg (Germany)

    2011-01-15

    To investigate the self-gating technique for MR imaging of the fetal heart in a sheep model. MR images of 6 fetal sheep heart were obtained at 1.5T. For self-gating MRI of the fetal heart a cine SSFP in short axis, two and four chamber view was used. Self-gated images were compared with real cardiac triggered MR images (pulse-wave triggering). MRI of the fetal heart was performed using both techniques simultaneously. Image quality was assessed and the left ventricular volume and function were measured and compared. Compared with pulse-wave triggering, the self-gating technique produced slightly inferior images with artifacts. Especially the atrial septum could not be so clearly depicted. The contraction of the fetal heart was shown in cine sequences in both techniques. The average blood volumes could be measured with both techniques with no significant difference: at end-systole 3.1 ml (SD{+-} 0.2), at end-diastole 4.9 ml ({+-}0.2), with ejection fractions at 38.6%, respectively 39%. Both self-gating and pulse-wave triggered cardiac MRI of the fetal heart allowed the evaluation of anatomical structures and functional information. Images obtained by self-gating technique were slightly inferior than the pulse-wave triggered MRI. (orig.)

  8. Stillbirth and fetal growth restriction.

    Science.gov (United States)

    Bukowski, Radek

    2010-09-01

    The association between stillbirth and fetal growth restriction is strong and supported by a large body of evidence and clinically employed for the stillbirth prediction. However, although assessment of fetal growth is a basis of clinical practice, it is not trivial. Essentially, fetal growth is a result of the genetic growth potential of the fetus and placental function. The growth potential is the driving force of fetal growth, whereas the placenta as the sole source of nutrients and oxygen might become the rate limiting element of fetal growth if its function is impaired. Thus, placental dysfunction may prevent the fetus from reaching its full genetically determined growth potential. In this sense fetal growth and its aberration provides an insight into placental function. Fetal growth is a proxy for the test of the effectiveness of placenta, whose function is otherwise obscured during pregnancy.

  9. Correction method for influence of tissue scattering for sidestream dark-field oximetry using multicolor LEDs

    Science.gov (United States)

    Kurata, Tomohiro; Oda, Shigeto; Kawahira, Hiroshi; Haneishi, Hideaki

    2016-10-01

    We have previously proposed an estimation method of intravascular oxygen saturation (SO_2) from the images obtained by sidestream dark-field (SDF) imaging (we call it SDF oximetry) and we investigated its fundamental characteristics by Monte Carlo simulation. In this paper, we propose a correction method for scattering by the tissue and performed experiments with turbid phantoms as well as Monte Carlo simulation experiments to investigate the influence of the tissue scattering in the SDF imaging. In the estimation method, we used modified extinction coefficients of hemoglobin called average extinction coefficients (AECs) to correct the influence from the bandwidth of the illumination sources, the imaging camera characteristics, and the tissue scattering. We estimate the scattering coefficient of the tissue from the maximum slope of pixel value profile along a line perpendicular to the blood vessel running direction in an SDF image and correct AECs using the scattering coefficient. To evaluate the proposed method, we developed a trial SDF probe to obtain three-band images by switching multicolor light-emitting diodes and obtained the image of turbid phantoms comprised of agar powder, fat emulsion, and bovine blood-filled glass tubes. As a result, we found that the increase of scattering by the phantom body brought about the decrease of the AECs. The experimental results showed that the use of suitable values for AECs led to more accurate SO_2 estimation. We also confirmed the validity of the proposed correction method to improve the accuracy of the SO_2 estimation.

  10. Correction method for influence of tissue scattering for sidestream dark-field oximetry using multicolor LEDs

    Science.gov (United States)

    Kurata, Tomohiro; Oda, Shigeto; Kawahira, Hiroshi; Haneishi, Hideaki

    2016-12-01

    We have previously proposed an estimation method of intravascular oxygen saturation (SO_2) from the images obtained by sidestream dark-field (SDF) imaging (we call it SDF oximetry) and we investigated its fundamental characteristics by Monte Carlo simulation. In this paper, we propose a correction method for scattering by the tissue and performed experiments with turbid phantoms as well as Monte Carlo simulation experiments to investigate the influence of the tissue scattering in the SDF imaging. In the estimation method, we used modified extinction coefficients of hemoglobin called average extinction coefficients (AECs) to correct the influence from the bandwidth of the illumination sources, the imaging camera characteristics, and the tissue scattering. We estimate the scattering coefficient of the tissue from the maximum slope of pixel value profile along a line perpendicular to the blood vessel running direction in an SDF image and correct AECs using the scattering coefficient. To evaluate the proposed method, we developed a trial SDF probe to obtain three-band images by switching multicolor light-emitting diodes and obtained the image of turbid phantoms comprised of agar powder, fat emulsion, and bovine blood-filled glass tubes. As a result, we found that the increase of scattering by the phantom body brought about the decrease of the AECs. The experimental results showed that the use of suitable values for AECs led to more accurate SO_2 estimation. We also confirmed the validity of the proposed correction method to improve the accuracy of the SO_2 estimation.

  11. Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue.

    Science.gov (United States)

    Svalestad, J; Hellem, S; Vaagbø, G; Irgens, A; Thorsen, E

    2010-01-01

    Laser Doppler flowmetry (LDF) and transcutaneous oximetry (TcPO(2)) are non-invasive techniques, widely used in the clinical setting, for assessing microvascular blood flow and tissue oxygen tension, e.g. recording vascular changes after radiotherapy and hyperbaric oxygen therapy. With standardized procedures and improved reproducibility, these methods might also be applicable in longitudinal studies. The aim of this study was to evaluate the reproducibility of facial skin and gingival LDF and facial skin TcPO(2). The subjects comprised ten healthy volunteers, 5 men, aged 31-68 years. Gingival perfusion was recorded with the LDF probe fixed to a custom made, tooth-supported acrylic splint. Skin perfusion was recorded on the cheek. TcPO(2) was recorded on the forehead and cheek and in the second intercostal space. The reproducibility of LDF measurements taken after vasodilation by heat provocation was greater than for basal flow in both facial skin and mandibular gingiva. Pronounced intraday variations were observed. Interweek reproducibility assessed by intraclass correlation coefficient ranged from 0.74 to 0.96 for LDF and from 0.44 to 0.75 for TcPO(2). The results confirm acceptable reproducibility of LDF and TcPO(2) in longitudinal studies in a vascular laboratory where subjects serve as their own controls. The use of thermoprobes is recommended. Repeat measurements should be taken at the same time of day.

  12. Fetal congenital lobar emphysema.

    Science.gov (United States)

    Chia, Chun-Chieh; Huang, Soon-Cen; Liu, Min-Chang; Se, Tung-Yi

    2007-03-01

    To report a rare fetal congenital lung anomaly characterized by over inflation of a pulmonary lobe. A 28-year-old systemic lupus erythematous mother, gravida 1 para 0, who had normal prenatal care in our department, was admitted for labor pain and an abnormal fetal heart location was noted incidentally during labor. The baby showed rib retraction in room air but no obvious cyanotic change after delivery. Both the fetus chest X-ray and ultrasound showed a hyperechogenic tumor in the left thoracic cavity with a right-side-shifted heart and trachea. Computed tomography showed a hypodense and multiseptal tumor in the left thoracic cavity with right-sided shift of the heart and trachea. It was a soft, solid tumor in the parenchyma of the left lung and the histopathology confirmed it to be benign congenital lobar emphysema. The favorable outcome in both asymptomatic and mildly symptomatic children suggests that a nonsurgical approach should be considered for these patients.

  13. The fetal circulation.

    Science.gov (United States)

    Kiserud, Torvid; Acharya, Ganesh

    2004-12-30

    Accumulating data on the human fetal circulation shows the similarity to the experimental animal physiology, but with important differences. The human fetus seems to circulate less blood through the placenta, shunt less through the ductus venosus and foramen ovale, but direct more blood through the lungs than the fetal sheep. However, there are substantial individual variations and the pattern changes with gestational age. The normalised umbilical blood flow decreases with gestational age, and, at 28 to 32 weeks, a new level of development seems to be reached. At this stage, the shunting through the ductus venosus and the foramen ovale reaches a minimum, and the flow through the lungs a maximum. The ductus venosus and foramen ovale are functionally closely related and represent an important distributional unit for the venous return. The left portal branch represents a venous watershed, and, similarly, the isthmus aorta an arterial watershed. Thus, the fetal central circulation is a very flexible and adaptive circulatory system. The responses to increased afterload, hypoxaemia and acidaemia in the human fetus are equivalent to those found in animal studies: increased ductus venosus and foramen ovale shunting, increased impedance in the lungs, reduced impedance in the brain, increasingly reversed flow in the aortic isthmus and a more prominent coronary blood flow.

  14. Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers.

    Science.gov (United States)

    Dubowitz, G; Breyer, K; Lipnick, M; Sall, J W; Feiner, J; Ikeda, K; MacLeod, D B; Bickler, P E

    2013-12-01

    Pulse oximetry is a standard of care during anaesthesia in high-income countries. However, 70% of operating environments in low- and middle-income countries have no pulse oximeter. The 'Lifebox' oximetry project set out to bridge this gap with an inexpensive oximeter meeting CE (European Conformity) and ISO (International Organization for Standardization) standards. To date, there are no performance-specific accuracy data on this instrument. The aim of this study was to establish whether the Lifebox pulse oximeter provides clinically reliable haemoglobin oxygen saturation (Sp O2 ) readings meeting USA Food and Drug Administration 510(k) standards. Using healthy volunteers, inspired oxygen fraction was adjusted to produce arterial haemoglobin oxygen saturation (Sa O2 ) readings between 71% and 100% measured with a multi-wavelength oximeter. Lifebox accuracy was expressed using bias (Sp O2 - Sa O2 ), precision (SD of the bias) and the root mean square error (Arms). Simultaneous readings of Sa O2 and Sp O2 in 57 subjects showed a mean (SD) bias of -0.41% (2.28%) and Arms 2.31%. The Lifebox pulse oximeter meets current USA Food and Drug Administration standards for accuracy, thus representing an inexpensive solution for patient monitoring without compromising standards.

  15. Fetal vibroacoustic stimulation for facilitation of tests of fetal wellbeing.

    Science.gov (United States)

    Tan, Kelvin H; Smyth, Rebecca M D; Wei, Xing

    2013-12-07

    Acoustic stimulation of the fetus has been suggested to improve the efficiency of antepartum fetal heart rate testing. To assess the advantages and disadvantages of the use of fetal vibroacoustic stimulation in conjunction with tests of fetal wellbeing. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2013). All published and unpublished randomised controlled trials assessing the merits of the use of fetal vibroacoustic stimulation in conjunction with tests of fetal wellbeing. All review authors independently extracted data and assessed trial quality. Authors of published and unpublished trials were contacted for further information. Altogether 12 trials with a total of 6822 participants were included. Fetal vibroacoustic stimulation reduced the incidence of non-reactive antenatal cardiotocography test (nine trials; average risk ratio (RR) 0.62, 95% confidence interval (CI) 0.48 to 0.81). Vibroacoustic stimulation compared with mock stimulation evoked significantly more fetal movements when used in conjunction with fetal heart rate testing (one trial, RR 0.23, 95% CI 0.18 to 0.29). Vibroacoustic stimulation offers benefits by decreasing the incidence of non-reactive cardiotocography and reducing the testing time. Further randomised trials should be encouraged to determine not only the optimum intensity, frequency, duration and position of the vibroacoustic stimulation, but also to evaluate the efficacy, predictive reliability, safety and perinatal outcome of these stimuli with cardiotocography and other tests of fetal wellbeing.

  16. Cirugía fetal

    Directory of Open Access Journals (Sweden)

    DR. B. Juan Luis Leiva

    2014-11-01

    Full Text Available El campo de la cirugía fetal es de reciente comienzo y rápida evolución. Con el avance en las herramientas de diagnóstico antenatal, la capacidad de diagnóstico de condiciones fetales susceptibles de ser tratadas in utero ha dado paso a una serie de procedimientos destinados a dar solución a situaciones que, de no ser por estas intervenciones, terminarían en un resultado adverso perinatal. Las técnicas descritas para la terapia fetal incluyen procedimientos percutáneos guiados por ultrasonido, cirugía fetal abierta y cirugía mínimamente invasiva. En este artículo se presentan las diversas condiciones fetales tributarias de cirugía fetal y se discuten las opciones terapéuticas actuales para cada una.

  17. Nutritional regulation of fetal growth.

    Science.gov (United States)

    Bloomfield, Frank H; Jaquiery, Anne L; Oliver, Mark H

    2013-01-01

    Fetal growth is largely regulated by nutritional supply. The placenta is responsible for fetal nutrient supply for much of pregnancy, but in early pregnancy nutrition is histiotrophic. Both placental size and efficiency, and fetal growth, may be affected by maternal nutritional state before and during very early pregnancy. In contrast, manipulating maternal nutrition during later stages of pregnancy has a smaller than expected effect on fetal growth. Maternal nutrition before and during early pregnancy also has a greater effect on gestation length than maternal nutrition later in pregnancy, suggesting that nutritional status may regulate both fetal growth trajectory and gestation length and that these two outcomes may be linked. Thus, determination of the nutritional factors regulating fetal growth, and potentially postnatal growth and body phenotype, may lie with the maternal nutritional status even before conception.

  18. MRI of the fetal spine

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Erin M. [Departement of Radiology, Children' s Hospital of Philadelphia, PA (United States)

    2004-09-01

    Magnetic resonance imaging of the fetal spine is a vital complement to fetal sonographic examination. Assessing the wide spectrum of spinal dysraphism, as well as spinal neoplasia, allows for more correct prenatal diagnoses, patient care planning, and patient counselling. Proper appraisal of the value of experimental procedures, such as fetal myelomeningocoele repair, requires a high level of diagnostic accuracy for the selection and follow-up of appropriate candidates. (orig.)

  19. Evaluation of Maternal and Fetal Outcomes in the Adolescents Pregnancy

    Directory of Open Access Journals (Sweden)

    Elif Ağaçayak

    2016-06-01

    Full Text Available Objective: In this study, our aim is to compare discussing maternal and fetal problems non-adolescent pregnancy with maternal and fetal problems in adolescent pregnancy that seen in hospital. Methods: 15-19 years of age (50 patients and 20-23 years (96 patients who gave birth at the Gynaecologi­cal and Obstetric Clinic under the Faculty of Medicine of Dicle University between January 2015-October 2015 were retrospectively evaluated. Age at birth, parity, blood pressure, pulse, gestational age, complications at birth, cesarean section indications, maternal biochemical pa­rameters, patients with preeclampsia and preterm birth, maternal and fetal complications were recorded. Results: Total number of births between January 2015- October 2015 were 1715 patients in our clinic. 62 of them (3.6% were observed in the adolescent group. Maternal blood transfusion needs were found to be significantly higher in the adolescent group (p=0.004. Fetal abnor­malities and fetal intensive care needs were found to be significantly higher in the adolescent group (p=0.014, p=0.018. Conclusion: Adolescent pregnancies were high-risk pregnancies in terms of maternal anemia and blood transfusion requirements and because of adverse perina­tal outcomes. Therefore, to reduce the adolescent preg­nancy and to minimize perinatal complications should be done more extensive studies.

  20. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.

    Directory of Open Access Journals (Sweden)

    Tomoki Kohyama

    Full Text Available Pulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2. When oxygen saturation by pulse oximeter (SpO2 overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH who spent their daily lives in a poor oxygen state.This prospective observational study recruited 32 patients with CTEPH undergoing elective cardiac catheterization. As we collected arterial blood samples in the catheter laboratory, SpO2 values were simultaneously recorded. Three pulse oximeters were used on each patient, and SpO2 values were compared with oximetry readings using a blood gas analyzer. To determine the optimal SpO2 value by which to detect hypoxemia (SaO2≦90%, we generated receiver operating characteristic (ROC curves for each pulse oximeter.The root mean square of each pulse oximeter was 1.79 (OLV-3100, 1.64 (N-BS, and 2.50 (Masimo Radical. The mean bias (SpO2 - SaO2 for the 90%-95% saturation range was significantly higher for Masimo Radical (0.19 +/- 1.78% [OLV-3100], 0.18 +/- 1.63% [N-BS], and 1.61 +/- 1.91% [Masimo Radical]; p<0.0001. The optimal SpO2 value to detect hypoxemia (SaO2≦90% was 89% for OLV-3100, 90% for N-BS, and 92% for Masimo Radical.We found that the biases and precision with which to detect hypoxemia differed among the three pulse oximeters. To avoid hypoxemia, the optimal SpO2 should be determined for each pulse oximeter.

  1. Ovine fetal necrobacillosis

    DEFF Research Database (Denmark)

    Agerholm, J.S.; Boye, Mette; Aalbæk, B.

    2007-01-01

    were found in several tissues. Histologically, placental lesions were characterized by locally diffuse infiltration of neutrophils, closely associated with abundant small Gram-negative and FISH-positive rods, thrombosis and necrosis. Lesions in the fetal-maternal interface were multifocal and consisted...... of villous necrosis and suppurative inflammation. Spread to the fetus from the placenta appeared to occur in two ways. Some fetuses had multifocal necrotizing hepatitis consistent with haematogenous spread through the umbilical vein; further dissemination to other organs occurred. Transplacental spread...

  2. Fetal cardiovascular physiology.

    Science.gov (United States)

    Rychik, J

    2004-01-01

    The cardiovascular system of the fetus is physiologically different than the adult, mature system. Unique characteristics of the myocardium and specific channels of blood flow differentitate the physiology of the fetus from the newborn. Conditions of increased preload and afterload in the fetus, such as sacrococcygeal teratoma and twin-twin transfusion syndrome, result in unique and complex pathophysiological states. Echocardiography has improved our understanding of human fetal cadiovasvular physiology in the normal and diseased states, and has expanded our capability to more effectively treat these disease processes.

  3. HEPATITIS ALOINMUNE FETAL

    Directory of Open Access Journals (Sweden)

    Fernando Álvarez C., Dr.

    2015-07-01

    Full Text Available La hepatitis aloinmune fetal, conocida anteriormente como hemocromatosis neonatal, ha demostrado en los últimos años ser una enfermedad completamente distinta a la hemocromatosis del adulto, tanto en su etiología como en su la fisiopatología. Este conocimiento abre nuevas perspectivas tanto en la prevención de la enfermedad en futuros embarazos, así como en el tratamiento con inmunoglobulina endovenosa en la madre durante el embarazo y eventualmente el tratamiento postnatal, en el que el trasplante de hígado juega un rol primordial.

  4. Clinical implications of fetal magnetocardiography

    NARCIS (Netherlands)

    Quartero, H.W.P.; Stinstra, J.G.; Golbach, E.G.M.; Meijboom, E.J.; Peters, M.J.

    2002-01-01

    Objectives To test the usefulness and reliability of fetal magnetocardiography as a diagnostic or screening tool, both for fetuses with arrhythmias as well as for fetuses with a congenital heart defect. Methods We describe 21 women with either a fetal arrhythmia or a congenital heart defect disc

  5. Restrictive dermopathy and fetal behaviour

    NARCIS (Netherlands)

    Mulder, EJH; Beemer, FA; Stoutenbeek, P

    2001-01-01

    We report three siblings from consecutive pregnancies affected with restrictive dermopathy (RD). During the second pregnancy, fetal behavioural development and growth were studied extensively using ultrasound at 1-4 week intervals. Dramatic and sudden changes occurred in fetal body movements and gro

  6. Feto-fetal transfusion syndrome

    Science.gov (United States)

    Galea, P; Scott, J M; Goel, K M

    1982-01-01

    Out of 42 pairs of liveborn monochorial twins there were 32 pairs with vascular anastomoses. Of these, 11 pairs had feto-fetal transfusion syndrome. There were another 8 pairs of stillborn twin fetuses with vascular communications and in these chronic feto-fetal transfusion syndrome might have resulted in intrauterine death. PMID:6890328

  7. Hormonal Control of Fetal Growth.

    Science.gov (United States)

    Cooke, Paul S.; Nicoll, Charles S.

    1983-01-01

    Summarizes recent research on hormonal control of fetal growth, presenting data obtained using a new method for studying the area. Effects of endocrine ablations and congenital deficiencies, studies of hormone/receptor levels, in-vitro techniques, hormones implicated in promoting fetal growth, problems with existing methodologies, and growth of…

  8. Impact of fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Simpson John

    2009-01-01

    Full Text Available Prenatal diagnosis of congenital heart disease is now well established for a wide range of cardiac anomalies. Diagnosis of congenital heart disease during fetal life not only identifies the cardiac lesion but may also lead to detection of associated abnormalities. This information allows a detailed discussion of the prognosis with parents. For continuing pregnancies, appropriate preparation can be made to optimize the postnatal outcome. Reduced morbidity and mortality, following antenatal diagnosis, has been reported for coarctation of the aorta, hypoplastic left heart syndrome, and transposition of the great arteries. With regard to screening policy, most affected fetuses are in the "low risk" population, emphasizing the importance of appropriate training for those who undertake such obstetric anomaly scans. As a minimum, the four chamber view of the fetal heart should be incorporated into midtrimester anomaly scans, and where feasible, views of the outflow tracts should also be included, to increase the diagnostic yield. Newer screening techniques, such as measurement of nuchal translucency, may contribute to identification of fetuses at high risk for congenital heart disease and prompt referral for detailed cardiac assessment.

  9. Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry.

    Directory of Open Access Journals (Sweden)

    Laura M Langan

    Full Text Available Advanced in vitro culture from tissues of different origin includes three-dimensional (3D organoid micro structures that may mimic conditions in vivo. One example of simple 3D culture is spheroids; ball shaped structures typically used as liver and tumour models. Oxygen is critically important in physiological processes, but is difficult to quantify in 3D culture: and the question arises, how small does a spheroid have to be to have minimal micro-environment formation? This question is of particular importance in the growing field of 3D based models for toxicological assessment. Here, we describe a simple non-invasive approach modified for the quantitative measurement and subsequent evaluation of oxygen gradients in spheroids developed from a non-malignant fish cell line (i.e. RTG-2 cells using Electron Paramagnetic Resonance (EPR oximetry. Sonication of the paramagnetic probe Lithium phthalocyanine (LiPc allows for incorporation of probe particulates into spheroid during its formation. Spectra signal strength after incorporation of probe into spheroid indicated that a volume of 20 μl of probe (stock solution: 0.10 mg/mL is sufficient to provide a strong spectra across a range of spheroid sizes. The addition of non-toxic probes (that do not produce or consume oxygen report on oxygen diffusion throughout the spheroid as a function of size. We provide evidence supporting the use of this model over a range of initial cell seeding densities and spheroid sizes with the production of oxygen distribution as a function of these parameters. In our spheroid model, lower cell seeding densities (∼2,500 cells/spheroid and absolute size (118±32 μm allow control of factors such as pre-existing stresses (e.g. ∼ 2% normoxic/hypoxic interface for more accurate measurement of treatment response. The applied methodology provides an elegant, widely applicable approach to directly characterize spheroid (and other organoid cultures in biomedical and

  10. A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection

    Directory of Open Access Journals (Sweden)

    Diwei He

    2015-07-01

    Full Text Available Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimentally measured AC and DC characteristics of individual circuits including the DC output voltage of the transimpedance amplifier, transimpedance gain of the transimpedance amplifier, and the central frequency and bandwidth of the analogue band-pass filters, show a good match (within 1% with the circuit simulations. With modulated light source and integrated lock-in detection the sensor effectively suppresses the interference from ambient light and 1/f noise. In a breath hold and release experiment the single chip sensor demonstrates consistent and comparable performance to commercial pulse oximetry devices with a mean of 1.2% difference. The single-chip sensor enables a compact and robust design solution that offers a route towards wearable devices for health monitoring.

  11. Fetal and Maternal Outcomes in Pregnancies Complicated with Fetal Macrosomia

    Science.gov (United States)

    Alsammani, Mohamed Alkahatim; Ahmed, Salah Roshdy

    2012-01-01

    Background: Fetal macrosomia remains a considerable challenge in current obstetrics due to the fetal and maternal complications associated with this condition. Aim: This study was designed to determine the prevalence of fetal macrosomia and associated fetal and maternal morbidity and mortality in the Al Qassim Region of Saudi Arabia. Materials and Methods: This register-based study was conducted from January 1, 2011 through December 30, 2011 at the Maternity and Child Hospital, Qassim, Saudi Arabia. Macrosomia was defined as birth weight of 4 kg or greater. Malformed babies and those born dead were excluded. Results: The total number of babies delivered was 9241; of these, 418 were macrosomic. Thus, the prevalence of fetal macrosomia was 4.5%. The most common maternal complications were postpartum hemorrhage (5 cases, 1.2%), perineal tear (7 cases, 1.7%), cervical lacerations (3 cases, 0.7%), and shoulder dystocia (40 cases, 9.6%) that resulted in 4 cases of Erb's palsy (0.96%), and 6 cases of bone fractures (1.4%). The rate of cesarean section among women delivering macrosomic babies was 47.6% (199), while 52.4% (219) delivered vaginally. Conclusion: Despite extensive efforts to reduce fetal and maternal complications associated with macrosomia, considerable fetal and maternal morbidity remain associated with this condition. PMID:22754881

  12. Fetal and maternal outcomes in pregnancies complicated with fetal macrosomia

    Directory of Open Access Journals (Sweden)

    Mohamed Alkhatim Alsammani

    2012-01-01

    Full Text Available Background: Fetal macrosomia remains a considerable challenge in current obstetrics due to the fetal and maternal complications associated with this condition. Aim: This study was designed to determine the prevalence of fetal macrosomia and associated fetal and maternal morbidity and mortality in the Al Qassim Region of Saudi Arabia. Materials and Methods: This register-based study was conducted from January 1, 2011 through December 30, 2011 at the Maternity and Child Hospital, Qassim, Saudi Arabia. Macrosomia was defined as birth weight of 4 kg or greater. Malformed babies and those born dead were excluded. Results: The total number of babies delivered was 9241; of these, 418 were macrosomic. Thus, the prevalence of fetal macrosomia was 4.5%. The most common maternal complications were postpartum hemorrhage (5 cases, 1.2%, perineal tear (7 cases, 1.7%, cervical lacerations (3 cases, 0.7%, and shoulder dystocia (40 cases, 9.6% that resulted in 4 cases of Erb′s palsy (0.96%, and 6 cases of bone fractures (1.4%. The rate of cesarean section among women delivering macrosomic babies was 47.6% (199, while 52.4% (219 delivered vaginally. Conclusion: Despite extensive efforts to reduce fetal and maternal complications associated with macrosomia, considerable fetal and maternal morbidity remain associated with this condition.

  13. Fetal acoustic stimulation test for early intrapartum fetal monitoring.

    Science.gov (United States)

    Goonewardene, M; Hanwellage, K

    2011-03-01

    The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p fetal well being in early labour. It complements the NST and is better than the NST alone.

  14. MR evaluation of fetal demise

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, Teresa; Chauvin, Nancy Anne; Johnson, Ann M.; Kramer, Sandra Sue; Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Capilla, Elena [Hospital Universitario Clinico San Carlos de Madrid, Madrid (Spain)

    2011-07-15

    Fetal demise is an uncommon event encountered at MR imaging. When it occurs, recognition by the interpreting radiologist is important to initiate appropriate patient management. To identify MR findings of fetal demise. Following IRB approval, a retrospective search of the radiology fetal MR database was conducted searching the words ''fetal demise'' and ''fetal death.'' Fetuses with obvious maceration or no sonographic confirmation of death were excluded. Eleven cases formed the study group. These were matched randomly to live fetuses of similar gestational age. Images were reviewed independently by three pediatric radiologists. The deceased fetus demonstrates decreased MR soft-tissue contrast and definition of tissue planes, including loss of gray-white matter differentiation in the brain. The signal within the cardiac chambers, when visible, is bright on HASTE sequences from the stagnant blood; the heart is small. Pleural effusions and decreased lung volumes may be seen. Interestingly, the fetal orbits lose their anatomical round shape and become smaller and more elliptical; a dark, irregular rim resembling a mask may be seen. Although fetal demise is uncommonly encountered at MR imaging, radiologists should be aware of such imaging findings so prompt management can be instituted. (orig.)

  15. Fetal valproate syndrome

    Directory of Open Access Journals (Sweden)

    Parmarth G Chandane

    2014-01-01

    Full Text Available Antenatal use of anticonvulsant valproic acid can result in a well-recognized cluster of facial dysmorphism, congenital anomalies and neurodevelopmental retardation. In this report, we describe a case with typical features of fetal valproate syndrome (FVS. A 26-year-old female with epilepsy controlled on sodium valproate 800 mg/day since 3 years, gave birth to a male child with characteristic features of FVS. She also had 3 spontaneous first-trimester abortions during those 3 years. Sodium valproate, a widely used anticonvulsant and mood regulator, is a well-recognized teratogen that can result in facial dysmorphism, craniosynostosis, neural tube defects, and neurodevelopmental retardation. Therefore, we strongly recommend avoidance of valproic acid and supplementation of folic acid during pregnancy.

  16. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.

    Science.gov (United States)

    Carter, B G; Carlin, J B; Tibballs, J; Mead, H; Hochmann, M; Osborne, A

    1998-06-01

    To evaluate the performance of two pulse oximeters in the measurement of arterial hemoglobin saturation in hypoxemic children. Prospective, repeated-measures observational study. A 16-bed pediatric intensive care unit in a children's tertiary hospital. Sixty-six patients with arterial saturation of Hewlett-Packard pulse oximeter yielding 155 data points (60 with saturations 75% and -0.8% and 8.0% Hewlett-Packard pulse oximeter were -0.5% and 5.1% >75% and 0.4% and 4.6% Hewlett-Packard. Regression coefficients for predicting change in cooximeter value given a change in the Ohmeda pulse oximeter were 0.59 and 0.71 75%, respectively. Similar coefficients for the Hewlett-Packard pulse oximeter were 0.50 and 0.70, respectively. The performance of the Ohmeda pulse oximeter deteriorated below an SpO2 of 75%. The Hewlett-Packard pulse oximeter performed consistently above and below an SpO2 of 75%. The ability of both pulse oximeters to reliably predict change in SaO2 based on change in pulse oximetry was limited. We recommend measurement of PaO2 or SaO2 for important clinical decisions.

  17. Fetal pain perception and pain management.

    Science.gov (United States)

    Van de Velde, Marc; Jani, Jacques; De Buck, Frederik; Deprest, J

    2006-08-01

    This paper gives an overview of current science related to the concept of fetal pain. We have answered three important questions: (1) does fetal pain exist? (2) does management of fetal pain benefit the unborn child? and (3) which techniques are available to provide good fetal analgesia?

  18. The Danish Fetal Medicine database

    DEFF Research Database (Denmark)

    Ekelund, Charlotte; Kopp, Tine Iskov; Tabor, Ann

    2016-01-01

    trimester ultrasound scan performed at all public hospitals in Denmark are registered in the database. Main variables/descriptive data: Data on maternal characteristics, ultrasonic, and biochemical variables are continuously sent from the fetal medicine units’Astraia databases to the central database via...... analyses are sent to the database. Conclusion: It has been possible to establish a fetal medicine database, which monitors first-trimester screening for chromosomal abnormalities and second-trimester screening for major fetal malformations with the input from already collected data. The database...

  19. Vascular stiffness determined from a nocturnal digital pulse wave signal: association with sleep, sleep-disordered breathing, and hypertension.

    Science.gov (United States)

    Svedmyr, Sven; Zou, Ding; Sommermeyer, Dirk; Ficker, Joachim H; Randerath, Winfried; Fietze, Ingo; Sanner, Bernd; Hedner, Jan; Grote, Ludger

    2016-12-01

    Reflection of the finger pulse wave form is a valid measure of arterial stiffness, which may be continuously assessed during sleep. We investigated the relationships between sleep, sleep-disordered breathing, hypertension, and pulse propagation time (PPT) in patients with suspected sleep apnea. The digital photoplethysmographic signal derived from finger pulse oximetry was recorded during overnight sleep studies in 440 patients (64% men, age 55 ± 12 years, BMI 30 ± 6 kg/m, apnea-hypopnea index 19 ± 19 n/h). PPT, defined as the time interval between the systolic and diastolic peak of the finger pulse wave, was calculated. The influence of sleep stages on PPT were assessed in patients undergoing polysomnography. Generalized linear models were used to study predictors of PPT and hypertension. Mean overnight PPT was independently associated with age (β = -1.34, P PPT was shorter in hypertensive patients compared with normotensive patients (160 ± 33 vs. 177 ± 47 ms, P PPT was influenced by sleep stage (highest PPT during slow wave sleep compared with wake and all other sleep stages, all P PPT by oximetry was strongly associated with factors known to determine daytime vascular stiffness. In addition, PTT provides information on functional and structural vascular properties during sleep. This novel technique offers new opportunities to noninvasively monitor vascular function during the sleeping period.

  20. Fetal and maternal analgesia/anesthesia for fetal procedures.

    Science.gov (United States)

    Van de Velde, Marc; De Buck, Frederik

    2012-01-01

    For many prenatally diagnosed conditions, treatment is possible before birth. These fetal procedures can range from minimal invasive punctions to full open fetal surgery. Providing anesthesia for these procedures is a challenge, where care has to be taken for both mother and fetus. There are specific physiologic changes that occur with pregnancy that have an impact on the anesthetic management of the mother. When providing maternal anesthesia, there is also an impact on the fetus, with concerns for potential negative side effects of the anesthetic regimen used. The question whether the fetus is capable of feeling pain is difficult to answer, but there are indications that nociceptive stimuli have a physiologic reaction. This nociceptive stimulation of the fetus also has the potential for longer-term effects, so there is a need for fetal analgesic treatment. The extent to which a fetus is influenced by the maternal anesthesia depends on the type of anesthesia, with different needs for extra fetal anesthesia or analgesia. When providing fetal anesthesia, the potential negative consequences have to be balanced against the intended benefits of blocking the physiologic fetal responses to nociceptive stimulation.

  1. Fetal laser therapy: applications in the management of fetal pathologies.

    Science.gov (United States)

    Mathis, Jérôme; Raio, Luigi; Baud, David

    2015-07-01

    Fetoscopic coagulation of placental anastomoses is the treatment of choice for severe twin-to-twin transfusion syndrome. In the present day, fetal laser therapy is also used to treat amniotic bands, chorioangiomas, sacrococcygeal teratomas, lower urinary tract obstructions and chest masses, all of which will be reviewed in this article. Amniotic band syndrome can cause limb amputation by impairing downstream blood flow. Large chorioangiomas (>4 cm), sacrococcygeal teratomas or fetal hyperechoic lung lesions can lead to fetal compromise and hydrops by vascular steal phenomenon or compression. Renal damage, bladder dysfunction and lastly death because of pulmonary hypolasia may be the result of megacystis caused by a posterior urethral valve. The prognosis of these pathologies can be dismal, and therapy options are limited, which has brought fetal laser therapy to the forefront. Management options discussed here are laser release of amniotic bands, laser coagulation of the placental or fetal tumor feeding vessels and laser therapy by fetal cystoscopy. This review, largely based on case reports, does not intend to provide a level of evidence supporting laser therapy over other treatment options. Centralized evaluation by specialists using strict selection criteria and long-term follow-up of these rare cases are now needed to prove the value of endoscopic or ultrasound-guided laser therapy.

  2. Fetal MRI: techniques and protocols

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Neuroradiology, University Clinics of Radiodiagnostics, Medical University Vienna, Waehringerguertel 18-10, 1090, Vienna (Austria); Brugger, Peter Christian [Department of Anatomy, Integrative Morphology Group, Medical University Vienna (Austria); Prayer, Lucas [Diagnosezentrum Urania, Vienna (Austria)

    2004-09-01

    The development of ultrafast sequences has led to a significant improvement in fetal MRI. Imaging protocols have to be adjusted to the rapidly developing fetal central nervous system (CNS) and to the clinical question. Sequence parameters must be changed to cope with the respective developmental stage, to produce images free from motion artefacts and to provide optimum visualization of the region and focus of interest. In contrast to postnatal studies, every suspect fetal CNS abnormality requires examination of the whole fetus and the extrafetal intrauterine structures including the uterus. This approach covers both aspects of fetal CNS disorders: isolated and complex malformations and cerebral lesions arising from the impaired integrity of the feto-placental unit. (orig.)

  3. Fetal-maternal erythrocyte distribution

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003407.htm Fetal-maternal erythrocyte distribution To use the sharing features ... unborn baby is leaking into the mother's blood circulation. The more of the baby's cells there are, ...

  4. The Danish Fetal Medicine Database

    DEFF Research Database (Denmark)

    Ekelund, Charlotte K; Petersen, Olav Bjørn; Jørgensen, Finn S

    2015-01-01

    OBJECTIVE: To describe the establishment and organization of the Danish Fetal Medicine Database and to report national results of first-trimester combined screening for trisomy 21 in the 5-year period 2008-2012. DESIGN: National register study using prospectively collected first-trimester screening...... data from the Danish Fetal Medicine Database. POPULATION: Pregnant women in Denmark undergoing first-trimester screening for trisomy 21. METHODS: Data on maternal characteristics, biochemical and ultrasonic markers are continuously sent electronically from local fetal medicine databases (Astraia Gmbh......%. The national screen-positive rate increased from 3.6% in 2008 to 4.7% in 2012. The national detection rate of trisomy 21 was reported to be between 82 and 90% in the 5-year period. CONCLUSION: A national fetal medicine database has been successfully established in Denmark. Results from the database have shown...

  5. Fetal ocular measurements by MRI.

    Science.gov (United States)

    Li, Xiao Bing; Kasprian, Gregor; Hodge, Jacqueline C; Jiang, Xiao Li; Bettelheim, Dieter; Brugger, Peter C; Prayer, Daniela

    2010-11-01

    To present fetal magnetic resonance imaging (MRI) ocular measurement ranges by gestational age (GA) in normal and growth-restricted fetuses. A total of 298 pregnant women from the 18th to the 39th week of gestation were imaged using MRI. Ocular measurements including binocular distance (BOD), interocular distance (IOD), transverse ocular diameter (OD) and anterior-posterior (AP) OD were measured. The curve estimation analyses for linear, logarithmic and quadratic models were performed. The ocular measurements of the fetuses with intrauterine growth restriction (IUGR) were compared with that of the normal fetuses. The fetal eye resembles an ellipsoid with significantly longer OD and shorter AP (t = - 22.07, p < 0.001). The quadratic model was the best model in predicting growth of the fetal BOD, IOD, OD and AP. The ocular measurements of the fetuses with IUGR were significantly different from that of the normal fetuses (BOD: t = 3.58, p < 0.001; IOD: t = 5.73, p < 0.001; OD: t = 3.52, p < 0.001; AP: t = 2.19, p < 0.05). Fetal ocular growth can be readily assessed by fetal MRI. Using the normative data provided in this study, fetal ocular anomalies may be detected. Ocular size is frequently reduced in the condition of IUGR, with potential pathologic impact on postnatal vision.

  6. Pulse Voltammetry.

    Science.gov (United States)

    Osteryoung, Janet

    1983-01-01

    Discusses the nature of pulse voltammetry, indicating that its widespread use arises from good sensitivity and detection limits and from ease of application and low cost. Provides analytical and mechanistic applications of the procedure. (JN)

  7. The cell-free fetal DNA fraction in maternal blood decreases after physical activity

    DEFF Research Database (Denmark)

    Schlütter, Jacob Mørup; Hatt, Lotte; Bach, Cathrine;

    2014-01-01

    of cycling with a pulse-rate of 150 beats per minute. The concentrations of cffDNA (DYS14) and cfDNA (RASSF1A) were assessed using quantitative real-time polymerase chain reaction. RESULTS: The fetal fraction decreased significantly in all participants after physical activity (p 

  8. Hemorrhage Near Fetal Rat Bone: Preliminary Results

    Science.gov (United States)

    Bigelow, Timothy A.; Miller, Rita J.; Blue, James P.; O'Brien, William D.

    2006-05-01

    High-intensity ultrasound has shown potential in treating many ailments requiring noninvasive tissue necrosis. However, little work has been done on using ultrasound to ablate pathologies on or near the developing fetus. For example, Congenital Cystic Adenomatoid Malformation (cyst on lungs), Sacrococcygeal Teratoma (benign tumor on tail bone), and Twin-Twin Transfusion Syndrome (one twin pumps blood to other twin) are selected problems that will potentially benefit from noninvasive ultrasound treatments. Before these applications can be explored, potential ultrasound-induced bioeffects should be understood. Specifically, ultrasound-induced hemorrhage near the fetal rat skull was investigated. An f/1 spherically focused transducer (5.1-cm focal length) was used to expose the skull of 18- to 19-day-gestation exteriorized rat fetuses. The ultrasound pulse had a center frequency of 0.92 MHz and pulse duration of 9.6 μs. The fetuses were exposed to 1 of 4 exposure conditions (denoted A, B, C, and D) in addition to a sham exposure. Three of the exposures consisted of a peak compressional pressure of 10 MPa, a peak rarefactional pressure of 6.7 MPa, and pulse repetition frequencies of 100 Hz (A), 250 Hz (B), and 500 Hz (C), corresponding to time-average intensities of 1.9 W/cm2, 4.7 W/cm2, and 9.4 W/cm2, respectively. Exposure D consisted of a peak compressional pressure of 6.7 MPa, a peak rarefactional pressure of 5.0 MPa, and a PRF of 500 Hz corresponding to a time-average intensity of 4.6 W/cm2. Hemorrhage occurrence increased slightly with increasing time-average intensity (i.e., 11% for A, 28% for B, 31% for C, and 19% for D with a 9% occurrence when the fetuses were not exposed). The low overall occurrence of hemorrhaging may be attributed to fetal motion (observed in over half of the fetuses from the backscattered echo during the exposure). The mean hemorrhage sizes were 3.1 mm2 for A, 2.5 mm2 for B, 2.7 mm2 for C, and 5.1 mm2 for D. The larger lesions at D may

  9. CLINICAL SIGNIFICANCE AND PROGNOSIS OF FETAL ARRHYTHMIAS

    Institute of Scientific and Technical Information of China (English)

    Qing-bo Fan; Ming-ying Gai; Jian-qiu Yang; Fei-fei Xing

    2004-01-01

    Objective To explore fetal arrhythmia clinical significance and its correlation with fetal prognosis.Methods Twenty-six cases of fetal arrhythmia detected among 12 799 pregnant women recorded over a ten-year period in Peking Uinon Medical College (PUMC) Hospital were reviewed retrospectively. Fetal arrhythmia was diagnosed by fetal auscultation, ultrasonography, electric fetal heart monitoring, and fetal echocardiography.Results Twenty-six fetuses were documented with fetal arrhythmia (3 tachycardia, 4 bradycardia, 19 normal heart rate with irregular fetal cardiac rhythm). The incidence of fetal arrhythmia in our hospital was 0.2%. They were diagnosed at the average of 35 weeks' gestation (15 to 41 weeks). Twenty-two cases were diagnosed by antenatal fetal auscultation, 1 case was diagnosed by ultrasonography, and 3 cases were diagnosed by electric fetal heart monitoring. Fetal echocardiograms were performed on 17 fetuses, 6 cases (35.3%) of which showed that ventricular premature beats with normal structure of fetal heart.All neonates survived postnatally and 24 of them (92.3%) were followed up. Echocardiograms were performed for 16 neonates and 2 of them were identified as atrial septal defects with normal heart rhythms. The results of follow-up showed that the two patients had no apparent clinical manifestation. The echocardiogram showed that atrial septal defect obliterated already.Conclusion The prognosis is well for most of the fetuses with arrhythmias, with low incidence of heart deformation.

  10. Design and Evaluation of a Low-Cost Smartphone Pulse Oximeter

    Directory of Open Access Journals (Sweden)

    Christian L. Petersen

    2013-12-01

    Full Text Available Infectious diseases such as pneumonia take the lives of millions of children in low- and middle-income countries every year. Many of these deaths could be prevented with the availability of robust and low-cost diagnostic tools using integrated sensor technology. Pulse oximetry in particular, offers a unique non-invasive and specific test for an increase in the severity of many infectious diseases such as pneumonia. If pulse oximetry could be delivered on widely available mobile phones, it could become a compelling solution to global health challenges. Many lives could be saved if this technology was disseminated effectively in the affected regions of the world to rescue patients from the fatal consequences of these infectious diseases. We describe the implementation of such an oximeter that interfaces a conventional clinical oximeter finger sensor with a smartphone through the headset jack audio interface, and present a simulator-based systematic verification system to be used for automated validation of the sensor interface on different smartphones and media players. An excellent agreement was found between the simulator and the audio oximeter for both oxygen saturation and heart rate over a wide range of optical transmission levels on 4th and 5th generations of the iPod TouchTM and iPhoneTM devices.

  11. Fetal privacy and confidentiality.

    Science.gov (United States)

    Botkin, J R

    1995-01-01

    With the advent of new and better contraceptive methods and the ability to facilitate and manipulate fertilization and gestation, couples will gain greater control over their fertility. Once a pregnancy has been established or an in vitro embryo created, the ability to evaluate the embryo and fetus will increase dramatically with progress in human genetic research. Preconception and preimplantation genetic testing and screening are now possible, and the technology to perform prenatal screening early in gestation is advancing rapidly. Nonsurgical methods facilitate induced abortion with a relatively lower degree of trauma upon the woman undergoing the procedure. These capabilities may all be used to enable and even encourage the genetic selection of future children. Despite the ethical concerns associated with prenatal testing and abortion, these services will continue to be an integral aspect of reproductive medicine. As technology advances, however, it will be possible to test and screen for conditions which do not produce serious defects. Genetic conditions which produce relatively mild impacts upon health will be identifiable in the embryo or fetus, while late-onset conditions and genetic factors which have only a probability of affecting health will also be located in the fetal genome. Prospective parents may therefore soon have the capability of selecting their most desirable embryo in vitro, or terminating all undesirable fetuses in vivo until the preferred child is delivered. The medical profession must take some responsibility for establishing guidelines on the use of reproductive technology. The standards of practice for the medical profession must reflect the results of a broad social debate over competing moral values. The author develops an argument for legal and ethical limitations on the application of prenatal testing and screening technology, suggesting that for some medical conditions, respect for the privacy and confidentiality of the fetus

  12. Fetal electrocardiogram (ECG) for fetal monitoring during labour.

    Science.gov (United States)

    Neilson, James P

    2015-12-21

    Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average

  13. Human fetal mesenchymal stem cells.

    Science.gov (United States)

    O'Donoghue, Keelin; Chan, Jerry

    2006-09-01

    Stem cells have been isolated at all stages of development from the early developing embryo to the post-reproductive adult organism. However, the fetal environment is unique as it is the only time in ontogeny that there is migration of stem cells in large numbers into different organ compartments. While fetal neural and haemopoietic stem cells (HSC) have been well characterised, only recently have mesenchymal stem cells from the human fetus been isolated and evaluated. Our group have characterised in human fetal blood, liver and bone marrow a population of non-haemopoietic, non-endothelial cells with an immunophenotype similar to adult bone marrow-derived mesenchymal stem cells (MSC). These cells, human fetal mesenchymal stem cells (hfMSC), are true multipotent stem cells with greater self-renewal and differentiation capacity than their adult counterparts. They circulate in first trimester fetal blood and have been found to traffic into the maternal circulation, engrafting in bone marrow, where they remain microchimeric for decades after pregnancy. Though fetal microchimerism has been implicated in the pathogenesis of autoimmune disease, the biological role of hfMSC microchimerism is unknown. Potential downstream applications of hfMSC include their use as a target cell for non-invasive pre-natal diagnosis from maternal blood, and for fetal cellular and gene therapy. Using hfMSC in fetal therapy offers the theoretical advantages of avoidance of immune rejection, increased engraftment, and treatment before disease pathology sets in. Aside from allogeneic hfMSC in utero transplantation, the use of autologous hfMSC has been brought a step forward with the development of early blood sampling techniques, efficient viral transduction and clonal expansion. Work is ongoing to determine hfMSC fate post-transplantation in murine models of genetic disease. In this review we will examine what is known about hfMSC biology, as well as discussing areas for future research. The

  14. Two cases of fetal goiter

    Directory of Open Access Journals (Sweden)

    Ashish Saini

    2012-01-01

    Full Text Available Introduction: Anterior fetal neck masses are rarely encountered. Careful routine ultrasound screening can reveal intrauterine fetal goiters (FGs. The incidence of goitrous hypothyroidism is 1 in 30,000-50,000 live births. The consequences of both FG and impaired thyroid function are serious. Aims and Objectives: To emphasize role of ultrasound in both invasive and non-invasive management of FG. Materials and Methods: Two pregnant patients, during second trimester, underwent routine antenatal ultrasound revealing FG, were investigated and managed. Results: Case 1: Revealed FG with fetal hypothyroidism. Intra-amniotic injection l-thyroxine given. Follow-up ultrasound confirmed the reduction of the goiter size. At birth, thyroid dyshormogenesis was suspected and neonate discharged on 50 mcg levothyroxine/day with normal growth and development so far. Case 2: Hypothyroid mother with twin pregnancy revealed FG, in twin 1, confirmed on magnetic resonance imaging (1.5 × 1.63 cm. The other twin had no thyroid swelling. Cordocentesis confirmed hypothyroidism in twin 1. Maternal thyroxine dose increased as per biochemical parameters leading to reduction in FG size. Mother delivered preterm and none of the twins had thyroid swelling. Fetal euthyroidism was confirmed on biochemical screening. Conclusion: FG during pregnancy should be thoroughly evaluated, diagnosed and immediately treated; although in utero options for fetal hypothyroidism management are available, emphasis should be laid on non-invasive procedures. Newer and better resolution techniques in ultrasonography are more specific and at the same time are less harmful.

  15. Fetal Programming and Cardiovascular Pathology

    Science.gov (United States)

    Alexander, Barbara T.; Dasinger, John Henry; Intapad, Suttira

    2016-01-01

    Low birth weight serves as a crude proxy for impaired growth during fetal life and indicates a failure for the fetus to achieve its full growth potential. Low birth weight can occur in response to numerous etiologies that include complications during pregnancy, poor prenatal care, parental smoking, maternal alcohol consumption or stress. Numerous epidemiological and experimental studies demonstrate that birth weight is inversely associated with blood pressure and coronary heart disease. Sex and age impact the developmental programming of hypertension. In addition, impaired growth during fetal life also programs enhanced vulnerability to a secondary insult. Macrosomia, which occurs in response to maternal obesity, diabetes and excessive weight gain during gestation, is also associated with increased cardiovascular risk. Yet, the exact mechanisms that permanently change the structure, physiology and endocrine health of an individual across their lifespan following altered growth during fetal life are not entirely clear. Transmission of increased risk from one generation to the next in the absence of an additional prenatal insult indicates an important role for epigenetic processes. Experimental studies also indicate that the sympathetic nervous system, the renin angiotensin system, increased production of oxidative stress and increased endothelin play an important role in the developmental programming of blood pressure in later life. Thus, this review will highlight how adverse influences during fetal life and early development program an increased risk for cardiovascular disease including high blood pressure and provide an overview of the underlying mechanisms that contribute to the fetal origins of cardiovascular pathology. PMID:25880521

  16. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  17. A Comparative Analysis of the Universal Elements of Music and the Fetal Environment

    Science.gov (United States)

    Teie, David

    2016-01-01

    Although the idea that pulse in music may be related to human pulse is ancient and has recently been promoted by researchers (Parncutt, 2006; Snowdon and Teie, 2010), there has been no ordered delineation of the characteristics of music that are based on the sounds of the womb. I describe features of music that are based on sounds that are present in the womb: tempo of pulse (pulse is understood as the regular, underlying beat that defines the meter), amplitude contour of pulse, meter, musical notes, melodic frequency range, continuity, syllabic contour, melodic rhythm, melodic accents, phrase length, and phrase contour. There are a number of features of prenatal development that allow for the formation of long-term memories of the sounds of the womb in the areas of the brain that are responsible for emotions. Taken together, these features and the similarities between the sounds of the womb and the elemental building blocks of music allow for a postulation that the fetal acoustic environment may provide the bases for the fundamental musical elements that are found in the music of all cultures. This hypothesis is supported by a one-to-one matching of the universal features of music with the sounds of the womb: (1) all of the regularly heard sounds that are present in the fetal environment are represented in the music of every culture, and (2) all of the features of music that are present in the music of all cultures can be traced to the fetal environment. PMID:27555828

  18. Multiresolution Approach for Noncontact Measurements of Arterial Pulse Using Thermal Imaging

    Science.gov (United States)

    Chekmenev, Sergey Y.; Farag, Aly A.; Miller, William M.; Essock, Edward A.; Bhatnagar, Aruni

    This chapter presents a novel computer vision methodology for noncontact and nonintrusive measurements of arterial pulse. This is the only investigation that links the knowledge of human physiology and anatomy, advances in thermal infrared (IR) imaging and computer vision to produce noncontact and nonintrusive measurements of the arterial pulse in both time and frequency domains. The proposed approach has a physical and physiological basis and as such is of a fundamental nature. A thermal IR camera was used to capture the heat pattern from superficial arteries, and a blood vessel model was proposed to describe the pulsatile nature of the blood flow. A multiresolution wavelet-based signal analysis approach was applied to extract the arterial pulse waveform, which lends itself to various physiological measurements. We validated our results using a traditional contact vital signs monitor as a ground truth. Eight people of different age, race and gender have been tested in our study consistent with Health Insurance Portability and Accountability Act (HIPAA) regulations and internal review board approval. The resultant arterial pulse waveforms exactly matched the ground truth oximetry readings. The essence of our approach is the automatic detection of region of measurement (ROM) of the arterial pulse, from which the arterial pulse waveform is extracted. To the best of our knowledge, the correspondence between noncontact thermal IR imaging-based measurements of the arterial pulse in the time domain and traditional contact approaches has never been reported in the literature.

  19. Physiology of the fetal circulation.

    Science.gov (United States)

    Kiserud, Torvid

    2005-12-01

    Our understanding of fetal circulatory physiology is based on experimental animal data, and this continues to be an important source of new insight into developmental mechanisms. A growing number of human studies have investigated the human physiology, with results that are similar but not identical to those from animal studies. It is time to appreciate these differences and base more of our clinical approach on human physiology. Accordingly, the present review focuses on distributional patterns and adaptational mechanisms that were mainly discovered by human studies. These include cardiac output, pulmonary and placental circulation, fetal brain and liver, venous return to the heart, and the fetal shunts (ductus venosus, foramen ovale and ductus arteriosus). Placental compromise induces a set of adaptational and compensational mechanisms reflecting the plasticity of the developing circulation, with both short- and long-term implications. Some of these aspects have become part of the clinical physiology of today with consequences for surveillance and treatment.

  20. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester

    Science.gov (United States)

    Sood, PB; Sharma, Arun; Madan, Manish; Shahi, Nishat; Gandhi, Geetanjali

    2015-01-01

    ABSTRACT Aim and objective: The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. Materials and methods: The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars in group III. Fifty children needing endodontics treatment formed test group IV. The readings were recorded as true positive (TP), false positive (FP), true negative (TN), false negative (FN). Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The results were statistically analyzed using Chi-square test. Results: On comparing pulse oximetry with electric pulp test ‘p-value’ was found to be 0.487 and 1.00 for groups 1 and 2 respectively and was statistically not significant. Whereas ‘p-value’ for groups 3 and 4 was < 0.0001 and 0.003 respectively and was statistically highly significant. Conclusion: The present study indicates that pulse oximetry can be used as a routine method for assessing the pulp vitality in primary, young permanent and mature permanent teeth. How to cite this article: Shahi P, Sood PB, Sharma A, Madan M, Shahi N, Gandhi G. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent 2015;8(2):94-98. PMID:26379374

  1. 3D ultrasound in fetal spina bifida.

    Science.gov (United States)

    Schramm, T; Gloning, K-P; Minderer, S; Tutschek, B

    2008-12-01

    3D ultrasound can be used to study the fetal spine, but skeletal mode can be inconclusive for the diagnosis of fetal spina bifida. We illustrate a diagnostic approach using 2D and 3D ultrasound and indicate possible pitfalls.

  2. CORD PROLAPSE, ASSOCIATED FACTORS AND FETAL OUTCOME

    African Journals Online (AJOL)

    We conducted this study to determine profile of pregnancy ... Several factors predispose to cord prolapse, amongst which are breech ... no fetal heart tones and only 31.8% of the babies were alive after ... Fetal death was, more common with.

  3. Births and deaths including fetal deaths

    Data.gov (United States)

    U.S. Department of Health & Human Services — Access to a variety of United States birth and death files including fetal deaths: Birth Files, 1968-2009; 1995-2005; Fetal death file, 1982-2005; Mortality files,...

  4. Macrosomia - maternal and fetal risk factors

    African Journals Online (AJOL)

    group; 3 cases of second-degree perineal laceration. ,,; 160 cm ... In order to make the diagnosis of fetal macrosomia antenatally ... real-time ultrasonography gives the best estimate of fetal .... Oats IN, Abell OA, Seischer NA, Broomhart GR.

  5. Fetal scalp blood sampling during labor

    DEFF Research Database (Denmark)

    Chandraharan, Edwin; Wiberg, Nana

    2014-01-01

    and Clinical Excellence guideline considers that fetal scalp blood sampling decreases instrumental delivery without differences in other outcome variables. The fetal scalp is supplied by vessels outside the skull below the level of the cranial vault, which is likely to be compressed during contractions......Fetal cardiotocography is characterized by low specificity; therefore, in an attempt to ensure fetal well-being, fetal scalp blood sampling has been recommended by most obstetric societies in the case of a non-reassuring cardiotocography. The scientific agreement on the evidence for using fetal...... scalp blood sampling to decrease the rate of operative delivery for fetal distress is ambiguous. Based on the same studies, a Cochrane review states that fetal scalp blood sampling increases the rate of instrumental delivery while decreasing neonatal acidosis, whereas the National Institute of Health...

  6. Fetal/neonatal alloimmune thrombocytopenia.

    Science.gov (United States)

    Sachs, Ulrich J

    2013-01-01

    In fetal/neonatal alloimmune thrombocytopenia (FNAIT), antibodies against paternal antigens present on fetal platelets are produced by the mother. These antibodies will cross the placenta and can cause thrombocytopenia of the unborn. One severe consequence of thrombocytopenia is intracranial bleeding which may lead to death or severe sequelae. FNAIT index cases in one family are usually detected at birth only since antenatal screening programmes have not been installed so far. Subsequent pregnancies of immunized mothers may require special diagnostic and prophylactic interventions, and interdisciplinary counselling and treatment involving obstetricians, pediatricians and immunohematologists may prove useful for optimized care. This short review covers pathogenesis, clinical presentation, diagnostic, and therapeutic options in FNAIT.

  7. Fetal epigenetic programming of adipokines.

    Science.gov (United States)

    Houde, Andrée-Anne; Hivert, Marie-France; Bouchard, Luigi

    2013-01-01

    Epigenetics generates a considerable interest in the field of research on complex traits, including obesity and diabetes. Recently, we reported a number of epipolymorphisms in the placental leptin and adiponectin genes associated with maternal hyperglycemia during pregnancy. Our results suggest that DNA methylation could partly explain the link between early exposure to a detrimental fetal environment and an increased risk to develop obesity and diabetes later in life. This brief report discusses the potential importance of adipokine epigenetic changes in fetal metabolic programming. Additionally, preliminary data showing similarities between methylation variations of different tissues and cell types will be presented along with the challenges and future perspectives of this emerging field of research.

  8. Prediction of fetal acidemia in placental abruption

    OpenAIRE

    MATSUDA, Yoshio; OGAWA, Masaki; KONNO, Jun; MITANI, Minoru; MATSUI, Hideo

    2013-01-01

    Background To determine the major predictive factors for fetal acidemia in placental abruption. Methods A retrospective review of pregnancies with placental abruption was performed using a logistic regression model. Fetal acidemia was defined as a pH of less than 7.0 in umbilical artery. The severe abruption score, which was derived from a linear discriminant function, was calculated to determine the probability of fetal acidemia. Results Fetal acidemia was seen in 43 survivors (43/222, 19%)....

  9. Practice Bulletin No. 173: Fetal Macrosomia.

    Science.gov (United States)

    2016-11-01

    Suspected fetal macrosomia is encountered commonly in obstetric practice. As birth weight increases, the likelihood of labor abnormalities, shoulder dystocia, birth trauma, and permanent injury to the neonate increases. The purpose of this document is to quantify those risks, address the accuracy and limitations of methods for estimating fetal weight, and suggest clinical management for a pregnancy with suspected fetal macrosomia.

  10. Unilateral Huge Hydronephrosis Necessitating Fetal Interventions

    Directory of Open Access Journals (Sweden)

    Ayşenur Cerrah Celayir

    2013-04-01

    Full Text Available Fetal intervention for obstructive uropathy was first performed at the University of California, San Francisco in 1981. Since then diagnostic criteria for fetal intervention have been laid down to assist in proper patient selection. Unilateral fetal hydronephrosis doesn’t require prenatal intervention; but prenatal intervention might be required in selected cases, especially when hydronephrosis compresses adjacent organs.

  11. Miniaturized pulse oximeter sensor for continuous vital parameter monitoring

    Science.gov (United States)

    Fiala, Jens; Reichelt, Stephan; Werber, Armin; Bingger, Philipp; Zappe, Hans; Förster, Katharina; Klemm, Rolf; Heilmann, Claudia; Beyersdorf, Friedhelm

    2007-07-01

    A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cu. which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.

  12. Fetal onset of general movements

    NARCIS (Netherlands)

    Luechinger, Annemarie B.; Hadders-Algra, Mijna; Van Kan, Colette M.; de Vries, JIP

    2008-01-01

    Perinatal qualitative assessment of general movements (GMs) is a tool to evaluate the integrity of the young nervous system. The aim of this investigation was to study the emergence of GMs. Fetal onset of GMs was studied sonographically in 18 fetuses during the first trimester of uncomplicated in vi

  13. The Fetal Modified Myocardial Performance Index: Is Automation the Future?

    Directory of Open Access Journals (Sweden)

    Priya Maheshwari

    2015-01-01

    Full Text Available The fetal modified myocardial performance index (Mod-MPI is a noninvasive, pulsed-wave Doppler-derived measure of global myocardial function. This review assesses the progress in technical refinements of its measurement and the potential for automation to be the crucial next step. The Mod-MPI is a ratio of isovolumetric to ejection time cardiac time intervals, and the potential for the left ventricular Mod-MPI as a tool to clinically assess fetal cardiac function is well-established. However, there are wide variations in published reference ranges, as (1 a standardised method of selecting cardiac time intervals used in Mod-MPI calculation has not been established; (2 cardiac time interval measurement currently requires manual, inherently subjective placement of callipers on Doppler ultrasound waveforms; and (3 ultrasound machine settings and ultrasound system type have been found to affect Mod-MPI measurement. Collectively these factors create potential for significant inter- and intraobserver measurement variability. Automated measurement of the Mod-MPI may be the next key development which propels the Mod-MPI into routine clinical use. A novel automated system of Mod-MPI measurement is briefly presented and its implications for the future of the Mod-MPI in fetal cardiology are discussed.

  14. Pulsed thermoelectricity

    Science.gov (United States)

    Apostol, M.; Nedelcu, M.

    2010-07-01

    A special mechanism of thermoelectric transport is described, consisting of pulses of charge carriers which "fly" periodically through the external circuit from the hot end of the sample to the cold end, with a determined duration of the "on" and "off" times of the electric contacts, while maintaining continuously the thermal contacts. It is shown that such a "resonant" ideal thermogenerator may work cyclically, with the same efficiency quotient as the ideal efficiency quotient of the thermoelectric devices operated in the usual stationary transport regime but the electric flow and power are increased, as a consequence of the concentration of the charge carriers on pulses of small spatial extent. The process is reversible, in the sense that it can be operated either as a thermoelectric generator or as an electrothermal cooler.

  15. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  16. Unsupervised fetal cortical surface parcellation

    Science.gov (United States)

    Dahdouh, Sonia; Limperopoulos, Catherine

    2016-03-01

    At the core of many neuro-imaging studies, atlas-based brain parcellations are used for example to study normal brain evolution across the lifespan. These atlases rely on the assumption that the same anatomical features are present on all subjects to be studied and that these features are stable enough to allow meaningful comparisons between different brain surfaces and structures These methods, however, often fail when applied to fetal MRI data, due to the lack of consistent anatomical features present across gestation. This paper presents a novel surface-based fetal cortical parcellation framework which attempts to circumvent the lack of consistent anatomical features by proposing a brain parcellation scheme that is based solely on learned geometrical features. A mesh signature incorporating both extrinsic and intrinsic geometrical features is proposed and used in a clustering scheme to define a parcellation of the fetal brain. This parcellation is then learned using a Random Forest (RF) based learning approach and then further refined in an alpha-expansion graph-cut scheme. Based on the votes obtained by the RF inference procedure, a probability map is computed and used as a data term in the graph-cut procedure. The smoothness term is defined by learning a transition matrix based on the dihedral angles of the faces. Qualitative and quantitative results on a cohort of both healthy and high-risk fetuses are presented. Both visual and quantitative assessments show good results demonstrating a reliable method for fetal brain data and the possibility of obtaining a parcellation of the fetal cortical surfaces using only geometrical features.

  17. Higher temporal resolution is necessary for continuous-wave near -infrared spectrophotometric monitors in both cerebral and muscular tissue oximetry

    Science.gov (United States)

    Chihara, Eiichi; Shiga, Toshikazu; Tanabe, Kazuhisa; Tanaka, Yoshifumi

    1998-01-01

    Conventional near infrared spectrophotometric monitors have temporal resolution of less than about 1 Hz. However, physiological Hb signals such as pulsation and muscle contraction have higher frequency than 1 Hz. Insufficient sampling rates inevitably lead aliasing of the recorded signals in tissue oximetry for both brain and muscle. Cerebral Hb signals (57 y.o. female artificially ventilated under general anesthesia) and thigh muscle (22 y.o. male with 20 W - 240 W exercise at 1 Hz cycling in semirecumbent ergometer) were measured with NIRS monitor with temporal resolution of 10 Hz (OMRON Co. Ltd., Japan). The detail of physiological fluctuations such as pulsation, ventilation, and muscle pumping was clearly recognized with a 10 Hz sampling. The comparison with recalculated waveforms at slower sampling rate (0.5 Hz, 1 Hz, 2 Hz) revealed that with slower sampling than 1 Hz cerebral respiratory waves were deformed by pulsation, and that magnitudes of muscle pumping could not be properly evaluated in dynamic exercise. In both pulsatile and muscle contractile cycle a phase delay between oxygenated component and deoxygenated one was also detected, which has been overlooked by conventional NIRS monitoring.

  18. Antithyroid drug-induced fetal goitrous hypothyroidism

    DEFF Research Database (Denmark)

    Rasmussen, Ase Krogh; Sundberg, Karin; Brocks, Vibeke

    2011-01-01

    Maternal overtreatment with antithyroid drugs can induce fetal goitrous hypothyroidism. This condition can have a critical effect on pregnancy outcome, as well as on fetal growth and neurological development. The purpose of this Review is to clarify if and how fetal goitrous hypothyroidism can...... be prevented, and how to react when prevention has failed. Understanding the importance of pregnancy-related changes in maternal thyroid status when treating a pregnant woman is crucial to preventing fetal goitrous hypothyroidism. Maternal levels of free T(4) are the most consistent indication of maternal...... and fetal thyroid status. In patients with fetal goitrous hypothyroidism, intra-amniotic levothyroxine injections improve fetal outcome. The best way to avoid maternal overtreatment with antithyroid drugs is to monitor closely the maternal thyroid status, especially estimates of free T(4) levels....

  19. THE MATERNAL-FETAL MEDICINE: AN UPDATE

    Directory of Open Access Journals (Sweden)

    Vincenzo Berghella

    2013-12-01

    Full Text Available The development of Maternal-Fetal Medicine is contributing to an improvement of maternal well-being and of neonatal health, introducing a number of new and useful technologies. Advances in genomics in the field of prenatal screening and diagnosis allowed the discovery of fragments of cell-free fetal DNA in the maternal circulation and the use of chromosomal microarrays, which can test for microdeletions and microduplications in addition to aneuploidies. Color Doppler applications during pregnancy are expanding exponentially and Doppler flow velocity waveforms indices have provided important information from maternal, placental and fetal circulation with clinical implications. Ultrasound monitoring of fetal growth represents a fundamental tool to evaluate fetal wellbeing and several methods have been developed to improve fetal weight estimation accuracy. The combination of new biophysical and biochemical markers is enriching Maternal-Fetal Medicine and more research will allow to improve pregnancy outcome.

  20. Ex vivo culture of human fetal gonads

    DEFF Research Database (Denmark)

    Jørgensen, A; Nielsen, J.E.; Perlman, S

    2015-01-01

    STUDY QUESTION: What are the effects of experimentally manipulating meiosis signalling by addition of retinoic acid (RA) in cultured human fetal gonads? SUMMARY ANSWER: RA-treatment accelerated meiotic entry in cultured fetal ovary samples, while addition of RA resulted in a dysgenetic gonadal...... phenotype in fetal testis cultures. WHAT IS KNOWN ALREADY: One of the first manifestations of sex differentiation is the initiation of meiosis in fetal ovaries. In contrast, meiotic entry is actively prevented in the fetal testis at this developmental time-point. It has previously been shown that RA......-treatment mediates initiation of meiosis in human fetal ovary ex vivo. STUDY DESIGN, SIZE, DURATION: This was a controlled ex vivo study of human fetal gonads treated with RA in 'hanging-drop' tissue cultures. The applied experimental set-up preserves germ cell-somatic niche interactions and the investigated...

  1. Management of fetal pain during invasive fetal procedures. A review.

    Science.gov (United States)

    Huang, W; Deprest, J; Missant, C; Van de Velde, M

    2004-01-01

    In recent years, fetal stress and analgesia draw more and more attention. Evidence that fetuses show a significant endocrinological and hemodynamical response to invasive stimuli, and that these responses can be blocked by analgesia, suggests that fetuses experience a stress response, even if this does not signify they experience "pain". Moreover, it is becoming increasingly clear that experiences of pain of a fetus will be "remembered" by the developing nervous system, perhaps for the entire life of the individual, which can probably lead to abnormal behavioural patterns or altered nociception. But up to now, the entire mechanism of fetal stress response and the optimal analgesic drug, dose and route of administration is not so clear.

  2. Prenatal diagnosis of congenital fetal heart abnormalities and clinical analysis*

    OpenAIRE

    Li,Hui; Wei, Jun; Ma, Ying; Shang, Tao

    2005-01-01

    Objective: To study the value of detecting fetal congenital heart disease (CHD) using the five transverse planes technique of fetal echocardiography. Methods: Nine hundred and eighty-two high-risk pregnancies for fetal CHD were included in this study, the fetal heart was scanned with the five transverse planes technique of fetal echocardiography described by Yagel, autopsy was conducted when pregnancy was terminated. Blood from fetal heart was collected for fetal chromosome analysis. A close ...

  3. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  4. Fetal evaluation of spine dysraphism

    Energy Technology Data Exchange (ETDEWEB)

    Bulas, Dorothy [George Washington University Medical Center, Division of Diagnostic Imaging and Radiology, Children' s National Medical Center, Washington, DC (United States)

    2010-06-15

    Spinal dysraphism or neural tube defects (NTD) encompass a heterogeneous group of congenital spinal anomalies that result from the defective closure of the neural tube early in gestation with anomalous development of the caudal cell mass. Advances in ultrasound and MRI have dramatically improved the diagnosis and therapy of spinal dysraphism and caudal spinal anomalies both prenatally and postnatally. Advances in prenatal US including high frequency linear transducers and three dimensional imaging can provide detailed information concerning spinal anomalies. MR imaging is a complementary tool that can further elucidate spine abnormalities as well as associated central nervous system and non-CNS anomalies. Recent studies have suggested that 3-D CT can help further assess fetal spine anomalies in the third trimester. With the advent of fetal therapy including surgery, accurate prenatal diagnosis of open and closed spinal dysraphism becomes critical in appropriate counselling and perinatal management. (orig.)

  5. Fetal origin of vascular aging

    Directory of Open Access Journals (Sweden)

    Shailesh Pitale

    2011-01-01

    Full Text Available Aging is increasingly regarded as an independent risk factor for development of cardiovascular diseases such as atherosclerosis and hypertension and their complications (e.g. MI and Stroke. It is well known that vascular disease evolve over decades with progressive accumulation of cellular and extracellular materials and many inflammatory processes. Metabolic syndrome, obesity and diabetes are conventionally recognized as risk factors for development of coronary vascular disease (CVD. These conditions are known to accelerate ageing process in general and vascular ageing in particular. Adverse events during intrauterine life may programme organ growth and favour disease later in life, popularly known as, ′Barker′s Hypothesis′. The notion of fetal programming implies that during critical periods of prenatal growth, changes in the hormonal and nutritional milieu of the conceptus may alter the full expression of the fetal genome, leading to permanent effects on a range of physiological.

  6. Fetal growth and developmental programming.

    Science.gov (United States)

    Galjaard, Sander; Devlieger, Roland; Van Assche, Frans A

    2013-01-01

    The environment in utero and in early neonatal life may induce a permanent response in the fetus and the newborn, leading to enhanced susceptibility to later diseases. This review concentrates on the role and mechanisms of events during the antenatal and immediate postnatal period resulting in later life diseases, concentrating on abnormal growth patterns of the fetus. Fetal overgrowth is related to exposure to a diabetic intra uterine environment, increasing the vulnerability to transgenerational obesity and hence an increased sensitivity to more diabetic mothers. This effect has been supported by animal data. Fetal growth restriction is complex due to malnutrition in utero, catch up growth due to a high caloric intake and low physical activity in later life. Metabolic changes and a transgenerational effect of intra uterine malnutrition has been supported by animal data. In recent years the discovery of alterations of the genome due to different influences during embryonic life, called epigenetics, has led to the phenomenon of fetal programming resulting in changing transgenerational metabolic effects.

  7. Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin.

    Science.gov (United States)

    Colquhoun, Douglas A; Forkin, Katherine T; Durieux, Marcel E; Thiele, Robert H

    2012-04-01

    The decision to administer blood products is complex and multifactorial. Accurate assessment of the concentration of hemoglobin [Hgb] is a key component of this evaluation. Recently a noninvasive method of continuously measuring hemoglobin (SpHb) has become available with multi-wavelength Pulse CO-Oximetry. The accuracy of this device is well documented, but the trending ability of this monitor has not been previously described. Twenty patients undergoing major thoracic and lumbar spine surgery were recruited. All patients received radial arterial lines. On the contralateral index finger, a R1 25 sensor (Rev E) was applied and connected to a Radical-7 Pulse CO-Oximeter (both Masimo Corp, Irvine, CA). Blood samples were drawn intermittently at the anesthesia provider's discretion and were analyzed by the operating room satellite laboratory CO-Oximeter. The value of Hgb and SpHb at that time point was compared. Trend analysis was performed by the four quadrant plot technique, testing directionality of change, and Critchley's polar plot method testing both directionality and magnitude of the change in values. Eighty-eight samples recorded at times of sufficient signal quality were available for analysis. Four quadrant plot analysis revealed 94% of data within the quadrants associated with the correct direction change, and 90% of data points lay within the analysis bounds proposed by Critchley. Pulse CO-Oximetry offers an acceptable trend monitor in patients undergoing major spine surgery. Future work should explore the ability of this device to detect large changes in hemoglobin, as well as its applicability in additional surgical and non-surgical patient populations.

  8. Fetal magnetic resonance: technique applications and normal fetal anatomy; Resonance magnetica fetal: tecnica aplicaciones y anatomia normal del feto

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.; Darnell, A.; Duran, C.; Mellado, F.; Corona, M [Corporacio Sanitaria del Parc Tauli. Sabadell (Spain)

    2003-07-01

    Ultrasonography is the preferred diagnostic imaging technique for intrauterine fetal examination. Nevertheless, circumstances sometimes dictate the use of other techniques in order to analyze fetal structures. The advent of ultra rapid magnetic resonance (MR) sequencing has led to the possibility of doing MR fetal studies, since images are obtained in an extradordiarily short time and are not affected by either maternal or fetal movements. It does not employ ionizing radiations, it provides high-contrast images and it can obtain such images in any plane of space without being influenced by either the child bearer's physical characteristics of fetal position. MR provides good quality images of most fetal organs. It is extremely useful in analysing distinct structures, as well as permitting an evaluation of cervical structures, lungs, diaphragms, intra-abdominal and retroperitoneal structures, and fetal extremities. It can also provide useful information regarding the placenta,umbilical cord, amniotic fluid and uterus. The objective of this work is to describe MR technique as applied to intrauterine fetal examination, and to illustrate normal fetal anatomy as manifested by MR and its applications. (Author) 42 refs.

  9. Fetal Behavior and Heart Rate in Twin Pregnancy : A Review

    NARCIS (Netherlands)

    Tendais, Iva; Visser, Gerard H. A.; Figueiredo, Barbara; Montenegro, Nuno; Mulder, Eduard J. H.

    2013-01-01

    Fetal movements and fetal heart rate (FHR) are well-established markers of fetal well-being and maturation of the fetal central nervous system. The purpose of this paper is to review and discuss the available knowledge on fetal movements and heart rate patterns in twin pregnancies. There is some evi

  10. Maternal psychological impact of fetal echocardiography.

    Science.gov (United States)

    Sklansky, Mark; Tang, Alvin; Levy, Denis; Grossfeld, Paul; Kashani, Iraj; Shaughnessy, Robin; Rothman, Abraham

    2002-02-01

    The maternal psychological impact of fetal echocardiography may be deleterious in the face of newly diagnosed congenital heart disease. This questionnaire-based study prospectively examined the psychological impact of both normal and abnormal fetal echocardiography. Normal fetal echocardiography decreased maternal anxiety, increased happiness, and increased the closeness women felt toward their unborn children. In contrast, when fetal echocardiography detected congenital heart disease, maternal anxiety typically increased, and mothers commonly felt less happy about being pregnant. However, among women who had recently delivered infants with congenital heart disease, those who had had fetal echocardiography during the pregnancy felt less responsible for their infants' defects and tended to have improved their relationships with the infants' fathers after the prenatal diagnosis of congenital heart disease. Further study of the psychological and medical impact of fetal echocardiography will be necessary to define and optimize the clinical value of this powerful diagnostic tool.

  11. Successful delivery of fetus with fetal inherited thrombophilia after two fetal deaths.

    Science.gov (United States)

    Juras, Josip; Ivanisević, Marina; Oresković, Slavko; Mihaljević, Slobodan; Vujić, Goran; Delmis, Josip

    2013-12-01

    A pregnant woman with inherited thrombophilia (factor II mutation--20210A) had two late pregnancy losses. The first pregnancy was not well documented, but the second pregnancy was complicated by fetal thrombophilia and umbilical artery thrombosis, proven after fetal death. During the third pregnancy enoxaparine was introduced in the therapy and early amniocentesis was performed. Fetal thrombophilia was proven again. Early delivery was induced and performed with no complications, resulting in a live healthy infant. A history of miscarriages or recurrent fetal loss should raise suspicion of thrombophilia as a potential cause. It is debatable whether amniocentesis in pursuit of fetal thrombophilia should be performed and whether this will lead to a better perinatal outcome. When fetal thrombophilia is diagnosed, an earlier induction of delivery should be considered, taking into account the fetal extrauterine viability. The aforementioned approach of early delivery in cases of inherited fetal thrombophilia could be a possible solution for better perinatal outcomes.

  12. Fetal macrosomia as an important indicator of fetal malformation syndrome: ultrasonic findings of two cases

    NARCIS (Netherlands)

    PA de Jong; MD E.J.M. Wouters; EA Pley

    1989-01-01

    Two extraordinary cases of fetal macrosomia are presented. It is discussed that extreme fetal growth should raise the suspicion of a malformation syndrome and deserves thorough antenatal ultrasonographic examination.

  13. A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypoperfusion in volunteers.

    Science.gov (United States)

    Kawagishi, Toshiya; Kanaya, Noriaki; Nakayama, Masayasu; Kurosawa, Saori; Namiki, Akiyoshi

    2004-09-01

    Important information may not be obtained if the pulse oximetry signal is lost during inflation of a cuff for blood pressure measurement, particularly in patients with hemodynamic instability. In the present study, we compared the failure times of pulse oximeters during cuff-induced hypoperfusion in volunteers. A pulse oximeter sensor was attached to the index finger, and a blood pressure cuff was attached to the same arm of each volunteer. MasimoSET Radical (Masimo), Nellcor N-395 (N-395), Nellcor N-20PA, and Nellcor D-25 were tested. To evaluate the failure time of each pulse oximeter, time to peak of cuff pressure, time to loss of signal, time to recovery of signal, and failure interval were measured. All measurements were performed three times for each pulse oximeter and were averaged. There were no differences in hemodynamic measurements among the groups. Time to loss of signal was longer in Masimo than the other pulse oximeters. Masimo and N-395 showed significantly shorter times to recovery of signal than those of the other two pulse oximeters. Failure interval was in the order of Masimo Masimo did not lose a signal as rapidly as the other oximeters studied. Masimo was similar in performance to the N-395 at providing useful data sooner than conventional technology after a loss of the signal. These observations suggest that data will be more available with fewer false-positive alarms when using the Masimo oximeter followed by the N-395 when compared with conventional oximeters.

  14. Altered fetal growth, placental abnormalities, and stillbirth.

    Science.gov (United States)

    Bukowski, Radek; Hansen, Nellie I; Pinar, Halit; Willinger, Marian; Reddy, Uma M; Parker, Corette B; Silver, Robert M; Dudley, Donald J; Stoll, Barbara J; Saade, George R; Koch, Matthew A; Hogue, Carol; Varner, Michael W; Conway, Deborah L; Coustan, Donald; Goldenberg, Robert L

    2017-01-01

    Worldwide, stillbirth is one of the leading causes of death. Altered fetal growth and placental abnormalities are the strongest and most prevalent known risk factors for stillbirth. The aim of this study was to identify patterns of association between placental abnormalities, fetal growth, and stillbirth. Population-based case-control study of all stillbirths and a representative sample of live births in 59 hospitals in 5 geographic areas in the U.S. Fetal growth abnormalities were categorized as small (90th percentile) for gestational age at death (stillbirth) or delivery (live birth) using a published algorithm. Placental examination by perinatal pathologists was performed using a standardized protocol. Data were weighted to account for the sampling design. Among 319 singleton stillbirths and 1119 singleton live births at ≥24 weeks at death or delivery respectively, 25 placental findings were investigated. Fifteen findings were significantly associated with stillbirth. Ten of the 15 were also associated with fetal growth abnormalities (single umbilical artery; velamentous insertion; terminal villous immaturity; retroplacental hematoma; parenchymal infarction; intraparenchymal thrombus; avascular villi; placental edema; placental weight; ratio birth weight/placental weight) while 5 of the 15 associated with stillbirth were not associated with fetal growth abnormalities (acute chorioamnionitis of placental membranes; acute chorioamionitis of chorionic plate; chorionic plate vascular degenerative changes; perivillous, intervillous fibrin, fibrinoid deposition; fetal vascular thrombi in the chorionic plate). Five patterns were observed: placental findings associated with (1) stillbirth but not fetal growth abnormalities; (2) fetal growth abnormalities in stillbirths only; (3) fetal growth abnormalities in live births only; (4) fetal growth abnormalities in stillbirths and live births in a similar manner; (5) a different pattern of fetal growth abnormalities in

  15. Normobaric Hypoxia as a Cognitive Stress Test for Mild Traumatic Brain Injury: Oculometrics, Pulse Oximetry, and the Self Report of Symptom Severity

    Science.gov (United States)

    2011-06-20

    ongoing medical problems; current or past neurological problems such as seizures , epilepsy or dementia; post-traumatic headache; current concentration...vision, sensitivity to light, hearing difficulties/loss, sensitivity to noise, seizure , transient neurological abnormalities, and numbness tingling...p < .001), the degrees of freedom (df) for the interaction ANOVA were corrected using Greenhouse-Geisser estimates (ε = .410) to produce F

  16. Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2) - a comparative study

    DEFF Research Database (Denmark)

    Jensen, Thomas; Duun, Sune Bro; Larsen, Jan

    2009-01-01

    ), and Mean Field ICA (ICAMF). The signal processing includes pre-processing bandpass filtering to eliminate noise, and post-processing by calculating the SpO2. The algorithms are compared to the commercial state-of-the-art algorithm Discrete Saturation Transform (DST) by Masimo Corporation...

  17. Isolated Fetal Ascite Associated with Cardiac Diseases

    Directory of Open Access Journals (Sweden)

    Vehbi Doğan

    2014-12-01

    Full Text Available Fetal ascite is defined as fluid accumulation in peritoneal cavity. It can be seen as isolated disease or an early sign of hydrops fetalis. Once fetal ascite is detected, a careful examination for hydops fetalis and possible underlying disease is necessary, since its prognosis and treatment depends mostly on the cause. Non-immunologic fetal ascite is an uncommon problem occurring for many reasons, such as urinary tract obstruction, congenital infections, genetic and metabolic diseases, gastrointestinal diseases and cardiovascular diseases. Here in this report we present two isolated fetal ascite that occurred secondary to cardiac diseases.

  18. MR imaging of the fetal brain

    Energy Technology Data Exchange (ETDEWEB)

    Glenn, Orit A. [University of California, San Francisco, Department of Radiology, Neuroradiology Section, San Francisco, CA (United States)

    2010-01-15

    Fetal MRI is clinically performed to evaluate the brain in cases where an abnormality is detected by prenatal sonography. These most commonly include ventriculomegaly, abnormalities of the corpus callosum, and abnormalities of the posterior fossa. Fetal MRI is also increasingly performed to evaluate fetuses who have normal brain findings on prenatal sonogram but who are at increased risk for neurodevelopmental abnormalities, such as complicated monochorionic twin pregnancies. This paper will briefly discuss the common clinical conditions imaged by fetal MRI as well as recent advances in fetal MRI research. (orig.)

  19. Magnetic resonance methods in fetal neurology.

    Science.gov (United States)

    Mailath-Pokorny, M; Kasprian, G; Mitter, C; Schöpf, V; Nemec, U; Prayer, D

    2012-10-01

    Fetal magnetic resonance imaging (MRI) has become an established clinical adjunct for the in-vivo evaluation of human brain development. Normal fetal brain maturation can be studied with MRI from the 18th week of gestation to term and relies primarily on T2-weighted sequences. Recently diffusion-weighted sequences have gained importance in the structural assessment of the fetal brain. Diffusion-weighted imaging provides quantitative information about water motion and tissue microstructure and has applications for both developmental and destructive brain processes. Advanced magnetic resonance techniques, such as spectroscopy, might be used to demonstrate metabolites that are involved in brain maturation, though their development is still in the early stages. Using fetal MRI in addition to prenatal ultrasound, morphological, metabolic, and functional assessment of the fetus can be achieved. The latter is not only based on observation of fetal movements as an indirect sign of activity of the fetal brain but also on direct visualization of fetal brain activity, adding a new component to fetal neurology. This article provides an overview of the MRI methods used for fetal neurologic evaluation, focusing on normal and abnormal early brain development. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Sindrome de respuesta inflamatoria fetal : adaptacion cardiovascular

    National Research Council Canada - National Science Library

    Arreaza-Graterol, Mortimer; Rojas-Barrera, Juan Diego; Molina-Giraldo, Saulo

    2011-01-01

    Introduccion: el sindrome de respuesta inflamatoria fetal es una condicion caracterizada por reaccion inflamatoria sistemica acompanada de alteraciones bioquimicas como la elevacion de la interleucina 6 (IL-6...

  1. Fetal Alcohol Syndrome a Global Problem

    Science.gov (United States)

    ... https://medlineplus.gov/news/fullstory_163096.html Fetal Alcohol Syndrome a Global Problem: Report Countries with highest alcohol use during pregnancy include Belarus, Britain, Denmark, Ireland ...

  2. Placental fetal vascular thrombosis lesions and maternal thrombophilia

    NARCIS (Netherlands)

    Beeksma, F. A.; Erwich, J. J. H. M.; Khong, T. Y.

    Aims: Following intrauterine fetal death (IUFD), the placental fetal vessels undergo regressive changes. These changes are virtually indistinguishable from lesions that are the result of fetal vascular thrombosis (FVT). This study investigated the relation between these lesions and maternal

  3. Is there a relationship between fetal brain function and the fetal behavioral state? A fetal MEG-study.

    Science.gov (United States)

    Kiefer-Schmidt, Isabelle; Raufer, Julia; Brändle, Johanna; Münßinger, Jana; Abele, Harald; Wallwiener, Diethelm; Eswaran, Hari; Preissl, Hubert

    2013-09-01

    Fetal magnetography enables the recording of biomagnetic fetal signals, including fetal heart and fetal brain signals. These signals allow the determination of fetal behavioral states and functional brain signals with auditory evoked responses (AER). In the current study, we investigated how the behavioral state influences the AER and how stimulation affects fetal state. One hundred and four fetuses in three age groups (28-31 weeks, 32-35 weeks and 36-41 weeks) were recorded with and without auditory stimulation. Both sessions were scored for fetal states. The AER latency was determined for each state separately. Forty-five additional subjects were recorded with two sessions of 10 min without stimulation to investigate a possible time effect on state changes. The state distribution was significantly different between stimulation and no stimulation conditions. The AER latencies were significantly shorter in active sleep (P=0.013) and active wakefulness (P=0.004) compared to quiet sleep. Auditory stimulation has an effect on fetal states. The state information should be taken into account for the analysis of AER latencies.

  4. Fetal cardiac rhabdomyoma: case report

    Directory of Open Access Journals (Sweden)

    Seyed Mostafa Ghavami

    2016-07-01

    Full Text Available Background: The primary manifestation of cardiac tumors in embryonic period is a very rare condition. Cardiac rhabdomyomas most frequently arise in the ventricular myocardium, they may also occur in the atria and the epicardial surface. In spite of its benign nature, the critical location of the tumor inside the heart can lead to lethal arrhythmias and chamber obstruction. Multiple rhabdomyomas are strongly associated with tuberous sclerosis which is associated with mental retardation and epilepsy of variable severity. Ultrasonography as a part of routine prenatal screening, is the best method for the diagnosis of cardiac rhabdomyomas. In the review of articles published in Iran, fetal cardiac rhabdomyoma was not reported. Case presentation: We report a case of cardiac rhabdomyoma on a 24-year-old gravid 1, referred to Day Medical Imaging Center for routine evaluation of fetal abnormalities at 31 weeks of her gestational age. Ultrasonographic examination displayed a homogenous echogenic mass (13×9mm, originating from the left ventricle of the fetal heart. It was a normal pregnancy without any specific complications. Other organs of the fetus were found normal and no cardiac abnormalities were appeared. No Pericardial fluid effusion was found. The parents did not have consanguineous marriage. They did not also have any specific disease such as tuberous sclerosis. Conclusion: The clinical features of cardiac rhabdomyomas vary widely, depending on the location, size, and number of tumors in the heart. Although cardiac rhabdomyoma is a benign tumor in many affected fetuses, an early prenatal diagnosis of the tumor is of great significance in making efficient planning and providing adequate follow up visits of the patients and the complications such as, heart failure and outlet obstruction of cardiac chambers.

  5. Excimer Laser Pulse Compress With Pulse Feedback

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>To attain a shorter laser pulse, a compressing technique called pulse feedback was developed from the saturation gain switch applied to the amplification in a discharge pumping excimer laser cavity. It can

  6. Fetal thermal effects of diagnostic ultrasound.

    Science.gov (United States)

    Abramowicz, Jacques S; Barnett, Stanley B; Duck, Francis A; Edmonds, Peter D; Hynynen, Kullervo H; Ziskin, Marvin C

    2008-04-01

    Processes that can produce a biological effect with some degree of heating (ie, about 1 degrees C above the physiologic temperature) act via a thermal mechanism. Investigations with laboratory animals have documented that pulsed ultrasound can produce elevations of temperature and damage in biological tissues in vivo, particularly in the presence of bone (intracranial temperature elevation). Acoustic outputs used to induce these adverse bioeffects are within the diagnostic range, although exposure times are usually considerably longer than in clinical practice. Conditions present in early pregnancy, such as lack of perfusion, may favor bioeffects. Thermally induced teratogenesis has been shown in many animal studies, as well as several controlled human studies; however, human studies have not shown a causal relationship between diagnostic ultrasound exposure during pregnancy and adverse biological effects to the fetus. All human epidemiologic studies, however, were conducted with commercially available devices predating 1992, that is, with acoustic outputs not exceeding a spatial-peak temporal-average intensity of 94 mW/cm2. Current limits in the United States allow a spatial-peak temporal-average intensity of 720 mW/cm2 for fetal applications. The synergistic effect of a raised body temperature (febrile status) and ultrasound insonation has not been examined in depth. Available evidence, experimental or epidemiologic, is insufficient to conclude that there is a causal relationship between obstetric diagnostic ultrasound exposure and obvious adverse thermal effects to the fetus. However, very subtle effects cannot be ruled out and indicate a need for further research, although research in humans may be extremely difficult to realize.

  7. Pulsed Optics

    Science.gov (United States)

    Hirlimann, C.

    Optics is the field of physics which comprises knowledge on the interaction between light and matter. When the superposition principle can be applied to electromagnetic waves or when the properties of matter do not depend on the intensity of light, one speaks of linear optics. This situation occurs with regular light sources such as light bulbs, low-intensity light-emitting diodes and the sun. With such low-intensity sources the reaction of matter to light can be characterized by a set of parameters such as the index of refraction, the absorption and reflection coefficients and the orientation of the medium with respect to the polarization of the light. These parameters depend only on the nature of the medium. The situation changed dramatically after the development of lasers in the early sixties, which allowed the generation of light intensities larger than a kilowatt per square centimeter. Actual large-scale short-pulse lasers can generate peak powers in the petawatt regime. In that large-intensity regime the optical parameters of a material become functions of the intensity of the impinging light. In 1818 Fresnel wrote a letter to the French Academy of Sciences in which he noted that the proportionality between the vibration of the light and the subsequent vibration of matter was only true because no high intensities were available. The intensity dependence of the material response is what usually defines nonlinear optics.

  8. Characteristics of children whose siblings have fetal alcohol syndrome or incomplete fetal alcohol syndrome.

    Science.gov (United States)

    Kvigne, Valborg L; Leonardson, Gary R; Borzelleca, Joseph; Neff-Smith, Martha; Welty, Thomas K

    2009-03-01

    To describe the clinical features of American Indian children born just before and just after a sibling with fetal alcohol syndrome or incomplete fetal alcohol syndrome. Two retrospective case-control studies were conducted of Northern Plains American Indian children with fetal alcohol syndrome or incomplete fetal alcohol syndrome identified from 1981 to 1993 by using International Classification of Diseases, Ninth Revision, Clinical Modification code 760.71. Compared with the controls, the 39 siblings born just before children with fetal alcohol syndrome (study 1) and 30 siblings born just before children with incomplete fetal alcohol syndrome (study 2) had more facial dysmorphology (23.1% and 16.7%, respectively), growth delay (38.5% and 10.0%), and central nervous system impairment (48.7% and 33.3%). The 20 siblings born just after children with fetal alcohol syndrome (study 1) and 22 siblings born just after children with incomplete fetal alcohol syndrome (study 2) had more facial dysmorphology (20.0% and 9.1%, respectively), growth delay (45.0% and 22.7%), and central nervous system impairment (50.0% and 31.8%) than the control siblings. The "before" siblings had characteristics of fetal alcohol syndrome that could have predicted that the next child was at risk for fetal alcohol syndrome. The "after" siblings had better outcomes than the previous siblings with fetal alcohol syndrome, a finding that was associated with a decrease in maternal alcohol consumption during the after-sibling pregnancy.

  9. Fetal deaths in Brazil: a systematic review

    Science.gov (United States)

    Barbeiro, Fernanda Morena dos Santos; Fonseca, Sandra Costa; Tauffer, Mariana Girão; Ferreira, Mariana de Souza Santos; da Silva, Fagner Paulo; Ventura, Patrícia Mendonça; Quadros, Jesirée Iglesias

    2015-01-01

    OBJECTIVE To review the frequency of and factors associated with fetal death in the Brazilian scientific literature. METHODS A systematic review of Brazilian studies on fetal deaths published between 2003 and 2013 was conducted. In total, 27 studies were analyzed; of these, 4 studies addressed the quality of data, 12 were descriptive studies, and 11 studies evaluated the factors associated with fetal death. The databases searched were PubMed and Lilacs, and data extraction and synthesis were independently performed by two or more examiners. RESULTS The level of completeness of fetal death certificates was deficient, both in the completion of variables, particularly sociodemographic variables, and in defining the underlying causes of death. Fetal deaths have decreased in Brazil; however, inequalities persist. Analysis of the causes of death indicated maternal morbidities that could be prevented and treated. The main factors associated with fetal deaths were absent or inadequate prenatal care, low education level, maternal morbidity, and adverse reproductive history. CONCLUSIONS Prenatal care should prioritize women that are most vulnerable (considering their social environment or their reproductive history and morbidities) with the aim of decreasing the fetal mortality rate in Brazil. Adequate completion of death certificates and investment in the committees that investigate fetal and infant deaths are necessary. PMID:25902565

  10. Fetal Pain, Abortion, Viability and the Constitution

    OpenAIRE

    Cohen, I. Glenn; Sayeed, Sadath Ali

    2011-01-01

    In early 2010, the Nebraska state legislature passed a new abortion restricting law asserting a new, compelling state interest in preventing fetal pain. In this article, we review existing constitutional abortion doctrine and note difficulties presented by persistent legal attention to a socially derived viability construct. We then offer a substantive biological, ethical, and legal critique of the new fetal pain rationale.

  11. Fetal pain, abortion, viability, and the Constitution.

    Science.gov (United States)

    Cohen, I Glenn; Sayeed, Sadath

    2011-01-01

    In early 2010, the Nebraska state legislature passed a new abortion restricting law asserting a new, compelling state interest in preventing fetal pain. In this article, we review existing constitutional abortion doctrine and note difficulties presented by persistent legal attention to a socially derived viability construct. We then offer a substantive biological, ethical, and legal critique of the new fetal pain rationale.

  12. Fetal Pain: Life in Troubled Waters

    OpenAIRE

    Johnson, Johnnye S.

    2007-01-01

    Maternal well-being is the key to fetal well-being. A fetus is highly vulnerable and sensitive to pain and stress, and exposure has the potential for negative developmental consequences. Childbirth educators can help raise parental awareness about the importance of the maternal environment for best outcomes in fetal development.

  13. Fetal behavior in normal dichorionic twin pregnancy

    NARCIS (Netherlands)

    Mulder, E. J. H.; Derks, J. B.; de Laat, M. W. M.; Visser, G. H. A.

    2012-01-01

    Objectives: A prospective study was performed to compare fetal behavioral development in healthy dichorionic twins and singletons, and identify twin intra-pair associations (synchrony) of fetal movements and rest-activity cycles using different criteria to define synchrony. Subjects and methods: Twe

  14. Fetal deaths in Brazil: a systematic review

    Directory of Open Access Journals (Sweden)

    Fernanda Morena dos Santos Barbeiro

    2015-01-01

    Full Text Available OBJECTIVE To review the frequency of and factors associated with fetal death in the Brazilian scientific literature. METHODS A systematic review of Brazilian studies on fetal deaths published between 2003 and 2013 was conducted. In total, 27 studies were analyzed; of these, 4 studies addressed the quality of data, 12 were descriptive studies, and 11 studies evaluated the factors associated with fetal death. The databases searched were PubMed and Lilacs, and data extraction and synthesis were independently performed by two or more examiners. RESULTS The level of completeness of fetal death certificates was deficient, both in the completion of variables, particularly sociodemographic variables, and in defining the underlying causes of death. Fetal deaths have decreased in Brazil; however, inequalities persist. Analysis of the causes of death indicated maternal morbidities that could be prevented and treated. The main factors associated with fetal deaths were absent or inadequate prenatal care, low education level, maternal morbidity, and adverse reproductive history. CONCLUSIONS Prenatal care should prioritize women that are most vulnerable (considering their social environment or their reproductive history and morbidities with the aim of decreasing the fetal mortality rate in Brazil. Adequate completion of death certificates and investment in the committees that investigate fetal and infant deaths are necessary.

  15. Fetal tissue transplant research: ethical dilemmas.

    Science.gov (United States)

    Farnam, C R

    1996-01-01

    The transplant of cells from fetal tissue shows promise as a therapy for certain diseases. The use and research of fetal tissue, and methods of obtaining the tissue, have raised ethical dilemmas. Consideration must be given concerning the mother, the fetus, and the tissue recipient.

  16. Expert systems for fetal assessment in labour

    NARCIS (Netherlands)

    Lutomski, J.E.; Meaney, S.; Greene, R.A.; Ryan, A.C.; Devane, D.

    2015-01-01

    BACKGROUND: Cardiotocography (CTG) records the fetal heart rate in relation to maternal uterine contractions and is one of the most common forms of fetal assessment during labour. Despite guidelines for CTG interpretation, substantial inter- and intra-observer variation in interpretation has been re

  17. Fetal stress hormone changes during intrauterine transfusions

    NARCIS (Netherlands)

    Adama van Scheltema, P.N.; Pasman, S.A.; Wolterbeek, R..; Deprest, J.A.; Oepkes, D.; Buck, F. De; Velde, M van de; Vandenbussche, F.P.H.A.

    2011-01-01

    OBJECTIVE: To document fetal stress hormone and Doppler changes after intrauterine transfusions (IUTs) in either the intrahepatic portion of the umbilical vein (IHV) or the placental cord insertion (PCI). METHOD: Pregnant women scheduled for IUT for fetal anemia (N = 25) were included prospectively.

  18. Fetal stress hormone changes during intrauterine transfusions

    NARCIS (Netherlands)

    Adama van Scheltema, P.N.; Pasman, S.A.; Wolterbeek, R..; Deprest, J.A.; Oepkes, D.; Buck, F. De; Velde, M van de; Vandenbussche, F.P.H.A.

    2011-01-01

    OBJECTIVE: To document fetal stress hormone and Doppler changes after intrauterine transfusions (IUTs) in either the intrahepatic portion of the umbilical vein (IHV) or the placental cord insertion (PCI). METHOD: Pregnant women scheduled for IUT for fetal anemia (N = 25) were included prospectively.

  19. Maternal diabetes and the fetal heart

    OpenAIRE

    Hornberger, L K

    2006-01-01

    Maternal diabetes mellitus significantly affects the fetal heart and fetal–placental circulation in both structure and function. The influence of pre‐conceptional diabetes begins during embryonic development in the first trimester, with altered cardiac morphogenesis and placental development. It continues to have an influence on the fetal circulation through the second and third trimesters and into the perinatal and neonatal period

  20. Fetal trauma from motor vehicle collisions.

    Science.gov (United States)

    Friese, Greg; Wojciehoski, Randal F

    2005-07-01

    To summarize: The best fetal protection is proper maternal use of seat belt restraints. All pregnant occupants in a motor vehicle crash require physician evaluation. Focus on maternal assessment. Maternal stability is the best indicator of fetal stability. Key treatments are high-flow oxygen, i.v. fluid loading and immobilizing in left lateral position. Evaluate the fetus after maternal stabilization.

  1. Aspects of Fetal Learning and Memory

    Science.gov (United States)

    Dirix, Chantal E. H.; Nijhuis, Jan G.; Jongsma, Henk W.; Hornstra, Gerard

    2009-01-01

    Ninety-three pregnant women were recruited to assess fetal learning and memory, based on habituation to repeated vibroacoustic stimulation of fetuses of 30-38 weeks gestational age (GA). Each habituation test was repeated 10 min later to estimate the fetal short-term memory. For Groups 30-36, both measurements were replicated in a second session…

  2. Digital atlas of fetal brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Teresa; Weinberger, E. [Department of Radiology, Seattle Children' s Hospital, Seattle, WA (United States); Matesan, Manuela [University of Washington, Department of Radiology, Seattle, WA (United States); Bulas, Dorothy I. [Division of Diagnostic Imaging and Radiology, Children' s National Medical Center, Washington, DC (United States)

    2010-02-15

    Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C, permits linked scrolling and resizing the images. Simultaneous comparison of varying gestational ages is permissible. Fetal brain images across gestational ages 18 to 37 weeks are provided as an interactive digital atlas and are available for free download. Improved interpretation of fetal brain abnormalities can be facilitated by the use of digital atlas cataloging of the normal changes throughout fetal development. Here we provide a description of the atlas and a discussion of normal fetal brain development. (orig.)

  3. Expert systems for fetal assessment in labour

    NARCIS (Netherlands)

    Lutomski, J.E.; Meaney, S.; Greene, R.A.; Ryan, A.C.; Devane, D.

    2015-01-01

    BACKGROUND: Cardiotocography (CTG) records the fetal heart rate in relation to maternal uterine contractions and is one of the most common forms of fetal assessment during labour. Despite guidelines for CTG interpretation, substantial inter- and intra-observer variation in interpretation has been

  4. The World Health Organization Fetal Growth Charts

    DEFF Research Database (Denmark)

    Kiserud, Torvid; Piaggio, Gilda; Carroli, Guillermo

    2017-01-01

    BACKGROUND: Perinatal mortality and morbidity continue to be major global health challenges strongly associated with prematurity and reduced fetal growth, an issue of further interest given the mounting evidence that fetal growth in general is linked to degrees of risk of common noncommunicable d...

  5. Fetal goiter and bilateral ovarian cysts

    DEFF Research Database (Denmark)

    Lassen, Pernille; Sundberg, Karin; Juul, Anders

    2008-01-01

    A unique case of fetal goiter accompanied by bilateral ovarian cysts in a mother treated with methimazole for Graves'disease is reported. The abnormal findings were detected by ultrasound at 31 weeks of gestation. Umbilical fetal blood sampling revealed elevated serum TSH, normal concentrations o...

  6. Fetal sex and preterm birth.

    Science.gov (United States)

    Challis, J; Newnham, J; Petraglia, F; Yeganegi, M; Bocking, A

    2013-02-01

    Rates of preterm birth vary between different populations and ethnic groups. Epidemiologic studies have suggested that the incidence of preterm birth is also higher in pregnancies carrying a male fetus; the male:female difference is greater in earlier preterm pregnancy. Placental or chorion trophoblast cells from pregnancies with a male fetus produced more pro-inflammatory TNFα in response to LPS stimulation and less anti-inflammatory IL-10 and granulocyte colony stimulating factor (G-CSF) than cells from pregnancies with a female fetus, more prostaglandin synthase (PTGS-2) and less prostaglandin dehydrogenase (PGDH). These results suggest that in the presence of a male fetus the trophoblast has the potential to generate a more pro-inflammatory environment. Maturation of the fetal hypothalamic-pituitary-adrenal axis and expression of placental genes, particularly 11β hydroxysteroid dehydrogenase-2 are also expressed in a sex dependent manner, consistent with the sex-biasing influences on gene networks. Sex differences in these activities may affect clinical outcomes of pre- and post-dates pregnancies and fetal/newborn wellbeing. These factors need consideration in studies of placental function and in the development of personalized strategies for the diagnosis of preterm labor and postnatal health. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Inter-eye comparison of retinal oximetry and vessel caliber between eyes with asymmetrical glaucoma severity in different glaucoma subtypes

    Directory of Open Access Journals (Sweden)

    Cheng CS

    2016-07-01

    differences in oximetric parameters or vessel calibers between the worse and the better eyes in POAG and NTG groups. Conclusion: Eyes with PACG showed increased arteriolar oxygen saturation and increased AV difference. This was not observed in POAG and NTG eyes. Arteriolar diameter in PACG and venular diameter in all three glaucoma groups were reduced. The difference observed in PACG eyes may be due to an increased metabolic demand in the disease process compared to open-angle glaucoma. Keywords: glaucoma, oximetry, retinal vessels, imaging

  8. Propofol Pharmacokinetics and Estimation of Fetal Propofol Exposure during Mid-Gestational Fetal Surgery: A Maternal-Fetal Sheep Model

    Science.gov (United States)

    Niu, Jing; Venkatasubramanian, Raja; Vinks, Alexander A.; Sadhasivam, Senthilkumar

    2016-01-01

    Background Measuring fetal drug concentrations is extremely difficult in humans. We conducted a study in pregnant sheep to simultaneously describe maternal and fetal concentrations of propofol, a common intravenous anesthetic agent used in humans. Compared to inhalational anesthesia, propofol supplemented anesthesia lowered the dose of desflurane required to provide adequate uterine relaxation during open fetal surgery. This resulted in better intraoperative fetal cardiac outcome. This study describes maternal and fetal propofol pharmacokinetics (PK) using a chronically instrumented maternal-fetal sheep model. Methods Fetal and maternal blood samples were simultaneously collected from eight mid-gestational pregnant ewes during general anesthesia with propofol, remifentanil and desflurane. Nonlinear mixed-effects modeling was performed by using NONMEM software. Total body weight, gestational age and hemodynamic parameters were tested in the covariate analysis. The final model was validated by bootstrapping and visual predictive check. Results A total of 160 propofol samples were collected. A 2-compartment maternal PK model with a third fetal compartment appropriately described the data. Mean population parameter estimates for maternal propofol clearance and central volume of distribution were 4.17 L/min and 37.7 L, respectively, in a typical ewe with a median heart rate of 135 beats/min. Increase in maternal heart rate significantly correlated with increase in propofol clearance. The estimated population maternal-fetal inter-compartment clearance was 0.0138 L/min and the volume of distribution of propofol in the fetus was 0.144 L. Fetal propofol clearance was found to be almost negligible compared to maternal clearance and could not be robustly estimated. Conclusions For the first time, a maternal-fetal PK model of propofol in pregnant ewes was successfully developed. This study narrows the gap in our knowledge in maternal-fetal PK model in human. Our study confirms

  9. Propofol Pharmacokinetics and Estimation of Fetal Propofol Exposure during Mid-Gestational Fetal Surgery: A Maternal-Fetal Sheep Model.

    Directory of Open Access Journals (Sweden)

    Pornswan Ngamprasertwong

    Full Text Available Measuring fetal drug concentrations is extremely difficult in humans. We conducted a study in pregnant sheep to simultaneously describe maternal and fetal concentrations of propofol, a common intravenous anesthetic agent used in humans. Compared to inhalational anesthesia, propofol supplemented anesthesia lowered the dose of desflurane required to provide adequate uterine relaxation during open fetal surgery. This resulted in better intraoperative fetal cardiac outcome. This study describes maternal and fetal propofol pharmacokinetics (PK using a chronically instrumented maternal-fetal sheep model.Fetal and maternal blood samples were simultaneously collected from eight mid-gestational pregnant ewes during general anesthesia with propofol, remifentanil and desflurane. Nonlinear mixed-effects modeling was performed by using NONMEM software. Total body weight, gestational age and hemodynamic parameters were tested in the covariate analysis. The final model was validated by bootstrapping and visual predictive check.A total of 160 propofol samples were collected. A 2-compartment maternal PK model with a third fetal compartment appropriately described the data. Mean population parameter estimates for maternal propofol clearance and central volume of distribution were 4.17 L/min and 37.7 L, respectively, in a typical ewe with a median heart rate of 135 beats/min. Increase in maternal heart rate significantly correlated with increase in propofol clearance. The estimated population maternal-fetal inter-compartment clearance was 0.0138 L/min and the volume of distribution of propofol in the fetus was 0.144 L. Fetal propofol clearance was found to be almost negligible compared to maternal clearance and could not be robustly estimated.For the first time, a maternal-fetal PK model of propofol in pregnant ewes was successfully developed. This study narrows the gap in our knowledge in maternal-fetal PK model in human. Our study confirms that maternal heart

  10. Invasive versus noninvasive hemoglobin measurement by pulse CO-Oximeter in neonates admitted to NICU

    Directory of Open Access Journals (Sweden)

    Hetal Vora

    2014-01-01

    Full Text Available Background Total haemoglobin measurement (tHb is one of the most commonly performed laboratory tests in patients admitted to the neonatal intensive care unit (NICU. Non invasive haemoglobin measurement is possible. In neonates this method can reduce iatrogenic blood loss. Studies performed in adults to compare haemoglobin (Hb obtained with the use of non-invasive Hb monitor and laboratory method has shown a clinically acceptable accuracy of non-invasive Hb measurements.(1 Masimo Rainbow SET, Pulse CO‐oximetry developed by Masimo Corporation leverages 7 wavelengths and advanced signal processing technique to measure total haemoglobin (SpHb values. The haemoglobin values measured through monitor is displayed continuously. This improves quality of care in babies by non invasive way. The monitor measures both pulse oximetry and SpHb with single probe which makes it advantageous (2 Objective. To compare transcutaneously spectroscopically measured hemoglobin values with venous hemoglobin values in neonates admitted to NICU. Study Design Prospective study in healthy preterm and term infants who were hemodynamically stable. Results Recordings were obtained from 76 stable infants (median gestational age at measurement: 36 weeks [range: 34–43 weeks]; median body weight: 1890 g [range: 1095–4360 g]. The spectroscopic haemoglobin values were corrected for inhomogeneous distribution of haemoglobin in the tissue. The venous and spectroscopic haemoglobin values were then compared by using the Bland- Altman method, which gave an error of <5%. Conclusions This is a good relation between the 2 methods for measuring haemoglobin. Larger studies are required to validate this non invasive method in those with conditions that affects the perfusion.

  11. Cerebral haemodynamic response to somatosensory stimulation in near-term fetal sheep.

    Science.gov (United States)

    Nakamura, S; Walker, D W; Wong, F Y

    2017-02-15

    Cerebral haemodynamic response to neural stimulation has been extensively investigated in animal and clinical studies, in both adult and paediatric populations, but little is known about cerebral haemodynamic functional response in the fetal brain. The present study describes the cerebral haemodynamic response measured by near-infrared spectroscopy to somatosensory stimulation in fetal sheep. The cerebral haemodynamic response in the fetal sheep brain changes from a positive (increase in oxyhaemoglobin (oxyHb)) response pattern to a negative or biphasic response pattern when the duration of somatosensory stimulation is increased, probably due to cerebral vasoconstriction with prolonged stimulations. In contrast to adult studies, we have found that changes in fetal cerebral blood flow and oxyHb are positively increased in response to somatosensory stimulation during hypercapnia. We propose this is related to reduced vascular resistance and recruitment of cerebral vasculature in the fetal brain during hypercapnia. Functional hyperaemia induced by a localised increase in neuronal activity has been suggested to occur in the fetal brain owing to a positive blood oxygen level-dependent (BOLD) signal recorded by functional magnetic resonance imaging following acoustic stimulation. To study the effect of somatosensory input on local cerebral perfusion we used near-infrared spectroscopy (NIRS) in anaesthetised, partially exteriorised fetal sheep where the median nerve was stimulated with trains of pulses (2 ms, 3.3 Hz) for durations of 1.8, 4.8 and 7.8 s. Signal averaging of cerebral NIRS responses to 20 stimulus trains repeated every 60 s revealed that a short duration of stimulation (1.8 s) increased oxyhaemoglobin in the contralateral cortex consistent with a positive functional response, whereas longer durations of stimulation (4.8, 7.8 s) produced more variable oxyhaemoglobin responses including positive, negative and biphasic patterns of change. Mean arterial

  12. Programmable pulse generator

    CERN Document Server

    Xue Zhi Hua; Duan Xiao Hui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  13. MRI of fetal acquired brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Radiodiagnostics, Medical University of Vienna (Austria)]. E-mail: daniela.prayer@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna (Austria); Kasprian, Gregor [Department of Radiodiagnostics, Medical University of Vienna (Austria); Witzani, Linde [Department of Radiodiagnostics, Medical University of Vienna (Austria); Helmer, Hanns [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria); Dietrich, Wolfgang [Department of Neurosurgery, Medical University of Vienna (Austria); Eppel, Wolfgang [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria); Langer, Martin [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria)

    2006-02-15

    Acquired fetal brain damage is suspected in cases of destruction of previously normally formed tissue, the primary cause of which is hypoxia. Fetal brain damage may occur as a consequence of acute or chronic maternal diseases, with acute diseases causing impairment of oxygen delivery to the fetal brain, and chronic diseases interfering with normal, placental development. Infections, metabolic diseases, feto-fetal transfusion syndrome, toxic agents, mechanical traumatic events, iatrogenic accidents, and space-occupying lesions may also qualify as pathologic conditions that initiate intrauterine brain damage. MR manifestations of acute fetal brain injury (such as hemorrhage or acute ischemic lesions) can easily be recognized, as they are hardly different from postnatal lesions. The availability of diffusion-weighted sequences enhances the sensitivity in recognizing acute ischemic lesions. Recent hemorrhages are usually readily depicted on T2 (*) sequences, where they display hypointense signals. Chronic fetal brain injury may be characterized by nonspecific changes that must be attributable to the presence of an acquired cerebral pathology. The workup in suspected acquired fetal brain injury also includes the assessment of extra-CNS organs that may be affected by an underlying pathology. Finally, the placenta, as the organ that mediates oxygen delivery from the maternal circulation to the fetus, must be examined on MR images.

  14. MRI of fetal acquired brain lesions.

    Science.gov (United States)

    Prayer, Daniela; Brugger, Peter C; Kasprian, Gregor; Witzani, Linde; Helmer, Hanns; Dietrich, Wolfgang; Eppel, Wolfgang; Langer, Martin

    2006-02-01

    Acquired fetal brain damage is suspected in cases of destruction of previously normally formed tissue, the primary cause of which is hypoxia. Fetal brain damage may occur as a consequence of acute or chronic maternal diseases, with acute diseases causing impairment of oxygen delivery to the fetal brain, and chronic diseases interfering with normal, placental development. Infections, metabolic diseases, feto-fetal transfusion syndrome, toxic agents, mechanical traumatic events, iatrogenic accidents, and space-occupying lesions may also qualify as pathologic conditions that initiate intrauterine brain damage. MR manifestations of acute fetal brain injury (such as hemorrhage or acute ischemic lesions) can easily be recognized, as they are hardly different from postnatal lesions. The availability of diffusion-weighted sequences enhances the sensitivity in recognizing acute ischemic lesions. Recent hemorrhages are usually readily depicted on T2 (*) sequences, where they display hypointense signals. Chronic fetal brain injury may be characterized by nonspecific changes that must be attributable to the presence of an acquired cerebral pathology. The workup in suspected acquired fetal brain injury also includes the assessment of extra-CNS organs that may be affected by an underlying pathology. Finally, the placenta, as the organ that mediates oxygen delivery from the maternal circulation to the fetus, must be examined on MR images.

  15. Fetal Primary Cardiac Tumors During Perinatal Period

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2017-06-01

    Full Text Available Fetal primary cardiac tumors are rare, but they may cause complications, which are sometimes life threatening, including arrhythmias, hydrops fetalis, ventricular outflow/inflow obstruction, cardiac failure, and even sudden death. Among fetal primary cardiac tumors, rhabdomyomas are most common, followed by teratomas, fibromas, hemangiomas, and myxomas. Everolimus, a mammalian target of rapamycin inhibitor, has been reported to be an effective drug to cause tumor remission in three neonates with multiple cardiac rhabdomyomas. Neonatal cardiac surgery for the resection of primary cardiac tumors found by fetal echocardiography has been reported sporadically. However, open fetal surgery for pericardial teratoma resection, which was performed successfully via a fetal median sternotomy in one case report, could be a promising intervention to rescue these patients with large pericardial effusions. These recent achievements undoubtedly encourage further development in early management of fetal cardiac tumors. Owing to the rarity of fetal primary cardiac tumors, relevant information in terms of prenatal diagnosis, treatment, and prognosis remains to be clarified.

  16. Fetal pain: an infantile debate.

    Science.gov (United States)

    Derbyshire, S W G

    2001-02-01

    The question of whether a fetus can experience pain is an immense challenge. The issue demands consideration of the physical and psychological basis of being and the relation between the two. At the center of this debate is the question of how it is that we are conscious, a question that has inspired the writing of some of our most brilliant contemporary philosophers and scientists, with one commentary suggesting surrender. In my earlier review I attempted to draw together the various strands of thinking that had attacked the question of fetal pain and relate them back to the bigger question of consciousness. In their vituperative response, Benatar and Benatar bite off my finger before looking to where I am pointing. I will examine each of their criticisms.

  17. Neurodevelopment after fetal growth restriction.

    Science.gov (United States)

    Baschat, Ahmet A

    2014-01-01

    Fetal growth restriction (FGR) can emerge as a complication of placental dysfunction and increases the risk for neurodevelopmental delay. Marked elevations of umbilical artery (UA) Doppler resistance that set the stage for cardiovascular and biophysical deterioration with subsequent preterm birth characterize early-onset FGR. Minimal, or absent UA Doppler abnormalities and isolated cerebral Doppler changes with subtle deterioration and a high risk for unanticipated term stillbirth are characteristic for late-onset FGR. Nutritional deficiency manifested in lagging head growth is the most powerful predictor of developmental delay in all forms of FGR. Extremes of blood flow resistance and cardiovascular deterioration, prematurity and intracranial hemorrhage increase the risks for psychomotor delay and cerebral palsy. In late-onset FGR, regional cerebral vascular redistribution correlates with abnormal behavioral domains. Irrespective of the phenotype of FGR, prenatal tests that provide precise and independent stratification of risks for adverse neurodevelopment have yet to be determined.

  18. Fetal alcohol syndrome: neuropsychiatric phenomics.

    Science.gov (United States)

    Burd, Larry; Klug, Marilyn G; Martsolf, John T; Kerbeshian, Jacob

    2003-01-01

    Fetal alcohol syndrome (FAS) is a common developmental disorder with impairments in multiple neuropsychiatric spheres of varying severity. Few population-derived studies of the behavioral phenotype are available. The purpose of this study was to estimate the prevalence of neuropsychiatric disorders in three groups: subjects who met criteria for FAS (n=152); subjects who met criteria for partial FAS/ARND (n=150); and referred subjects who did not meet criteria for either FAS or partial FAS/ARND (n=86). Each subject had a standardized evaluation by a medical geneticist. All subjects were from North Dakota. We found increases in the prevalence rates of neuropsychiatric disorders in subjects with FAS compared to subjects with partial FAS/ARND and the lowest rates in the group that did not meet criteria for either FAS or partial FAS/ARND. Comorbid attention deficit hyperactivity disorder occurred in 73% of cases with FAS, in 72% cases with partial FAS/ARND, and in 36% subjects who did not meet criteria for either. For other neuropsychiatric disorders, a similar distribution of comorbidity was found. This study supports the concept of a continuum of impairment resulting from prenatal alcohol exposure. The presence of complex cognitive, behavioral, and physical symptomatology in the affected subjects with prenatal alcohol exposure would seem to fit well under the diagnostic rubric of fetal alcohol spectrum disorder (FASD). Diagnosis and long-term management will require increasing access to multidisciplinary child development teams including mental health professionals who treat children and adolescents. Adults will require care primarily from teams with expertise in mental health and developmental disabilities.

  19. [Advanced MRI techniques of the fetal brain].

    Science.gov (United States)

    Schöpf, V; Dittrich, E; Berger-Kulemann, V; Kasprian, G; Kollndorfer, K; Prayer, D

    2013-02-01

    Evaluation of the normal and pathological fetal brain. Magnetic resonance imaging (MRI). Advanced MRI of the fetal brain. Diffusion tensor imaging (DTI) is used in clinical practice, all other methods are used at a research level. Serving as standard methods in the future. Combined structural and functional data for all gestational ages will allow more specific insight into the developmental processes of the fetal brain. This gain of information will help provide a common understanding of complex spatial and temporal procedures of early morphological features and their impact on cognitive and sensory abilities.

  20. Peripheral tissue oximetry

    DEFF Research Database (Denmark)

    Hyttel-Sorensen, Simon; Hessel, Trine Witzner; Greisen, Gorm

    2014-01-01

    , and response to changing oxygenation by the down slope of rStO2 during vascular occlusion in the respective arm. 10 healthy adults, 21-29 years old, with double skinfolds on the forearm less than 10 mm participated. The median rStO2 was 70.7% (interquartile range (IQR) 7.7%), 68.4% (IQR 8.4%), and 64.6% (IQR 4...

  1. Software method for extracting photoplethysmography in pulse oximeter%脉搏血氧仪中光电容积脉搏波的软件检出方法

    Institute of Scientific and Technical Information of China (English)

    张虹; 孙卫新; 金捷

    2001-01-01

    脉搏血氧仪中光电容积脉搏波的正确提取和检出是完成氧饱和度测量任务的主要环节之一. 为了克服传统设计中采用硬件电路完成脉搏波提取和检出时所带来的系统整体设计复杂,稳定性和重复性差等缺点,作者研究了光电容积脉搏波的软件提取和检出方法,为脉搏血氧饱和度检测系统的数字化设计奠定了基础.%Correct extraction of the photoplethysmography is one of the primary procedures to measure the oxygen saturation in the pulse oximeter. In order to overcome the problems of complex system design, instability and bad repetition which are brought about by analog circuits for completing the photoplethysmography extraction in conventional pulse oximetry systems, the author studied the software method to extract the photoplethysmography which will be the basis for digitizing the design of the pulse oximetry systems.

  2. Decreased fetal movements at home were recorded by a newly developed fetal movement recorder in a case of a non-reassuring fetal status.

    Science.gov (United States)

    Ryo, Eiji; Kamata, Hideo; Seto, Michiharu

    2014-10-01

    A fetal movement acceleration measurement (FMAM) recorder was developed for home monitoring of fetal movements. We provided a 32-year-old pregnant woman with the FMAM recorder to home monitor fetal movements, thereby self-recording decreased fetal movements at 30 weeks' gestation. On routine checkup, a non-stress test revealed scant fetal heart rate accelerations. At 31 weeks' gestation, the woman underwent an emergent caesarean delivery because of a non-reassuring fetal heart rate pattern, and delivered a female neonate weighing 1312 g, whose umbilical cord was slightly narrowed at the umbilicus. Our experience with the present case suggests the usefulness of the FMAM recorder.

  3. Normalized spectral power of fetal heart rate variability is associated with fetal scalp blood pH

    NARCIS (Netherlands)

    van Laar, J. O.; Peters, C. H. L.; Houterman, S.; Wijn, P. F. F.; Kwee, A.; Oei, S. G.

    Background: Spectral power of fetal heart rate variability is related to fetal condition. Previous studies found an increased normalized low frequency power in case of severe fetal acidosis. Aims: To analyze whether absolute or normalized low or high frequency power of fetal heart rate variability

  4. Fetal magnetic resonance imaging: methods and techniques; Fetale Magnetresonanztomographie: Methoden und Technik

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.C. [Zentrum fuer Anatomie und Zellbiologie, Medizinische Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie; Stuhr, F.; Lindner, C.; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    Since the introduction of fetal magnetic resonance imaging (MRI) into prenatal diagnostics, advances in coil technology and development of ultrafast sequences have further enhanced this technique. At present numerous sequences are available to visualize the whole fetus with high resolution and image quality, even in late stages of pregnancy. Taking into consideration the special circumstances of examination and adjusting sequence parameters to gestational age, fetal anatomy can be accurately depicted. The variety of sequences also allows further characterization of fetal tissues and pathologies. Fetal MRI not only supplies additional information to routine ultrasound studies, but also reveals fetal morphology and pathology in a way hitherto not possible. (orig.) [German] Seit Einfuehrung der fetalen Magnetresonanztomographie (MRT) in die praenatale Diagnostik wurde das Verfahren durch neue Spulentechniken und die Entwicklung ultraschneller Sequenzen kontinuierlich weiter entwickelt. Gegenwaertig steht eine Vielzahl von Sequenzen zur Verfuegung, die es erlauben, mit hoher Bildqualitaet und raeumlicher Aufloesung selbst in fortgeschrittenen Schwangerschaftsstadien den gesamten Feten darzustellen. Unter Beruecksichtigung der speziellen Untersuchungsbedingungen und des Schwangerschaftsalters kann so die fetale Anatomie genau abgebildet werden. Die Vielfalt an Sequenzen und deren gezielter Einsatz ermoeglichen es weiter, fetale Gewebe und Pathologien naeher zu charakterisierten. Auf diese Weise liefert die fetale MRT nicht nur Zusatzinformationen zur Routineultraschalluntersuchung, sie gibt auch Aufschluss ueber bestimmte fetale Morphologien und Pathologien, die bisher nicht darstellbar waren. (orig.)

  5. Contribution of Fetal, but Not Adult, Pulmonary Mesothelium to Mesenchymal Lineages in Lung Homeostasis and Fibrosis.

    Science.gov (United States)

    von Gise, Alexander; Stevens, Sean M; Honor, Leah B; Oh, Jin Hee; Gao, Chi; Zhou, Bin; Pu, William T

    2016-02-01

    The lung is enveloped by a layer of specialized epithelium, the pulmonary mesothelium. In other organs, mesothelial cells undergo epithelial-mesenchymal transition and contribute to organ stromal cells. The contribution of pulmonary mesothelial cells (PMCs) to the developing lung has been evaluated with differing conclusions. PMCs have also been indirectly implicated in lung fibrosis in the progressive, fatal lung disease idiopathic pulmonary fibrosis. We used fetal or postnatal genetic pulse labeling of PMCs to assess their fate in murine development, normal lung homeostasis, and models of pulmonary fibrosis. We found that most fetal PMC-derived mesenchymal cells (PMCDCs) expressed markers of pericytes and fibroblasts, only a small minority expressed smooth muscle markers, and none expressed endothelial cell markers. Postnatal PMCs did not contribute to lung mesenchyme during normal lung homeostasis or in models of lung fibrosis. However, fetal PMCDCs were abundant and actively proliferating within fibrotic regions in lung fibrosis models, suggesting that they actively participate in the fibrotic process. These data clarify the role of fetal and postnatal PMCDCs in lung development and disease.

  6. Fetal bowel anomalies - US and MR assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rubesova, Erika [Stanford University, Department of Radiology, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2012-01-15

    The technical quality of prenatal US and fetal MRI has significantly improved during the last decade and allows an accurate diagnosis of bowel pathology prenatally. Accurate diagnosis of bowel pathology in utero is important for parental counseling and postnatal management. It is essential to recognize the US presentation of bowel pathology in the fetus in order to refer the patient for further evaluation or follow-up. Fetal MRI has been shown to offer some advantages over US for specific bowel abnormalities. In this paper, we review the normal appearance of the fetal bowel on US and MRI as well as the typical presentations of bowel pathologies. We discuss more specifically the importance of recognizing on fetal MRI the abnormalities of size and T1-weighted signal of the meconium-filled distal bowel. (orig.)

  7. Changing patterns of fetal lung maturity testing

    National Research Council Canada - National Science Library

    McGinnis, K T; Brown, J A; Morrison, J C

    2008-01-01

    In our laboratory, a decrease in fetal lung maturity (FLM) testing on amniotic fluid occurred over a 10-year period, and we desired to determine if this was a national phenomenon and, if present, ascertain possible etiologies...

  8. Practice Bulletin No. 173: Fetal Macrosomia

    National Research Council Canada - National Science Library

    2016-01-01

    Suspected fetal macrosomia is encountered commonly in obstetric practice. As birth weight increases, the likelihood of labor abnormalities, shoulder dystocia, birth trauma, and permanent injury to the neonate increases...

  9. Practice Bulletin No. 173 Summary: Fetal Macrosomia

    National Research Council Canada - National Science Library

    2016-01-01

    Suspected fetal macrosomia is encountered commonly in obstetric practice. As birth weight increases, the likelihood of labor abnormalities, shoulder dystocia, birth trauma, and permanent injury to the neonate increases...

  10. Fetal diffusion imaging: pearls and solutions.

    Science.gov (United States)

    Kasprian, Gregor; Del Río, Maria; Prayer, Daniela

    2010-12-01

    Recently, diffusion-weighted (DWI) magnetic resonance imaging of the fetus has evolved from a basic research application to an important diagnostic imaging tool in fetal magnetic resonance imaging. Although technically challenging and still plagued with several sources of artifacts, DWI can add clinically important information, which cannot be provided by any other prenatal imaging modality. Its potential to noninvasively probe tissue structures on the basis of Brownian molecular motion enables the detection of early changes associated with acute fetal diseases, as well as structural alterations of functionally diverse compartments of different fetal organs. In this article, the current clinical applications of fetal brain and body DWI are outlined, as well as its current limitations.

  11. Diagnostic pitfalls in fetal brain MRI.

    Science.gov (United States)

    Al-Mukhtar, Ali; Kasprian, Gregor; Schmook, Maria T; Brugger, Peter C; Prayer, Daniela

    2009-08-01

    Recent technological advances in fetal magnetic resonance imaging (MRI) and increased reliability of MRI in depicting abnormalities and lesions, especially in the central nervous system, are increasingly bringing up challenging issues with regard to accurate diagnosis. There are also pitfalls not only attributable to image acquisition but also in clinical interpretation. The misinterpretation of findings because of insufficient knowledge about fetal brain development as visualized by MRI may also be regarded as an important limitation of fetal MRI. We provide an overview of the most common pitfalls experienced in fetal MRI in routine practice, demonstrate how to identify some of the factors that lead to imaging misinterpretation, and suggest ways to tackle these problems, with an emphasis on MR techniques and image calibration.

  12. [Effect of music on fetal behaviour].

    Science.gov (United States)

    Malinova, M; Malinova, M

    2004-01-01

    Antenatal music stimulation shown to elicit fetal heart rate and body movement responses, indicating that prenatal experience with music influences auditory functional development. The slower tempo resulted in less movement variation.

  13. Fetal magnetocardiography: Methods for rapid data reduction

    Science.gov (United States)

    Mosher, John C.; Flynn, Edward R.; Quinn, A.; Weir, A.; Shahani, U.; Bain, R. J. P.; Maas, P.; Donaldson, G. B.

    1997-03-01

    Fetal magnetocardigraphy (fMCG) provides a unique method for noninvasive observations of the fetal heart. Electrical currents generated by excitable tissues within the fetal heart yield measurable external magnetic fields. Measurements are performed with superconducting quantum interference devices inductively coupled to magnetometer or gradiometer coils, and the resulting signals are converted to digital form in the data acquisition system. The measured fields are usually contaminated by fetal and maternal movements (usually respiration), other physiological fields such as skeletal muscle contraction, the maternal cardiac signal, and environmental electromagnetic fields. Sensitivity to relatively distant sources, both physiological and environmental, is substantially reduced by the use of magnetic gradiometers. Other contaminants may be removed by proper signal conditioning which may be automatically applied using "black box" algorithms that are transparent to the user and highly efficient. These procedures can rapidly reduce the complex signal plus noise waveforms to the desired fMCG with minimal operator interference.

  14. Piracetam for fetal distress in labour.

    Science.gov (United States)

    Hofmeyr, G Justus; Kulier, Regina

    2012-06-13

    Piracetam is thought to promote the metabolism of brain cells when they are hypoxic. It has been used to prevent adverse effects of fetal distress. The objective of this review was to assess the effects of piracetam for suspected fetal distress in labour on method of delivery and perinatal morbidity. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (15 February 2012). Randomised trials of piracetam compared with placebo or no treatment for suspected fetal distress in labour. Both review authors assessed eligibility and trial quality. One study of 96 women was included. Piracetam compared with placebo was associated with a trend to reduced need for caesarean section (risk ratio 0.57, 95% confidence interval 0.32 to 1.03). There were no statistically significant differences between the piracetam and placebo group for neonatal morbidity (measured by neonatal respiratory distress) or Apgar score. There is not enough evidence to evaluate the use of piracetam for fetal distress in labour.

  15. Oximetry: A Reflective Tool for the Detection of Physiological Expression of Emotions in a Science Education Classroom

    Science.gov (United States)

    Calderón, Olga

    2016-01-01

    The pulse oximeter is a device that measures the oxygen concentration (or oxygen saturation--SpO[subscript 2]); heart rate, and heartbeat of a person at any given time. This instrument is commonly used in medical and aerospace fields to monitor physiological outputs of a patient according to health conditions or physiological yields of a flying…

  16. Erythropoietin elevation in the chronically hyperglycemic fetal lamb

    Energy Technology Data Exchange (ETDEWEB)

    Philipps, A.F. (Univ. of Connecticut Health Center, Farmington) Widness, J.A.; Garcia, J.F.; Raye, J.R.; Swartz, R.

    1982-05-01

    The effects of chronic fetal glucose infusion upon fetal oxygenation and endogenous erythropoietin (Ep) production were studied using the chronically catheterized fetal lamb. Fetal glucose infusion at rates between 5 and 20 mg/kg/min resulted in sustained fetal hyperglycemia. During glucose infusion (maximal glucose concentration achieved = 55.4 +/- 3.7 mg/dl) fetal arterial oxygen contents fell from 5.8 +/- 0.9 to 4.2 +/- 1.0 ml/dl while no changes were observed in simultaneously sampled, noninfused twins. Although plasma insulin concentration rose in the infused fetuses, the elevations were inconstant and no relationship between fetal plasma insulin concentration and decrement in fetal oxygen content was evident. The changes in plasma Ep concentration were noted prior to any significant fetal metabolic acidosis (as evidence of tissue hypoxia) and no changes in plasma Ep concentration were observed in simultaneously sampled noninfused twins. No relationship was apparent between fetal arterial plasma insulin and Ep concentrations. Since neither fetal anemia nor hemodilution occurred in these preparations, glucose-induced fetal hyposemia is the likely mechanism behind elevated fetal Ep concentrations in these experiments. Similarities between this animal model and human fetuses and infants of diabetic mothers suggest that chronic in utero hypoxemia may be a common feature responsible for such diverse abnomalities as polycythemia, hyperbilirubinemia, and late fetal demise. The mechanism behind the glucose-induced fetal hypoxemia is not known.

  17. Fetal MR imaging of Kniest dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Zeynep [Uludag University, Faculty of Medicine, Department of Radiology, Gorukle (Turkey); Kline-Fath, Beth M.; Laor, Tal [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Tinkle, Bradley T. [Cincinnati Children' s Hospital Medical Center, Division of Human Genetics, Cincinnati, OH (United States)

    2010-03-15

    We present a case of Kniest dysplasia, a rare form of the type II collagenopathies, with prenatal MRI. Sonography revealed only short limbs in the fetus. Fetal MRI findings included enlarged hyaline cartilaginous structures with abnormally high T2 signal intensity, delayed ossification of the pubic and ischial bones, and platyspondyly. By delineating the cartilaginous abnormalities, fetal MRI can contribute to the prenatal diagnosis of chondrodysplasias. (orig.)

  18. Impact of Oxidative Stress in Fetal Programming

    Directory of Open Access Journals (Sweden)

    Loren P. Thompson

    2012-01-01

    Full Text Available Intrauterine stress induces increased risk of adult disease through fetal programming mechanisms. Oxidative stress can be generated by several conditions, such as, prenatal hypoxia, maternal under- and overnutrition, and excessive glucocorticoid exposure. The role of oxidant molecules as signaling factors in fetal programming via epigenetic mechanisms is discussed. By linking oxidative stress with dysregulation of specific target genes, we may be able to develop therapeutic strategies that protect against organ dysfunction in the programmed offspring.

  19. Biomedical Instruments for Fetal and Neonatal Surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Rolfe, P [Oxford BioHorizons Ltd. (United Kingdom); Scopesi, F [Gaslini Institute, University of Genoa (Italy); Serra, G [Gaslini Institute, University of Genoa (Italy)

    2006-10-15

    Specialised instruments have been developed to aid the care of the fetus and the newborn baby. Miniature sensors using optical, electrical, chemical, mechanical and magnetic principles have been produced for capturing key measurands. These include temperature, pressure, flow and dimension, as well as several specific molecules such as glucose, oxygen and carbon dioxide. During pregnancy ultrasound imaging and blood flow techniques provide valuable information concerning fetal abnormalities, fetal growth, fetal breathing and fetal heart rate. Signal processing and pattern recognition can be useful for deriving indicators of fetal distress and clinical status, based on biopotentials as well as ultrasound signals. Fetal pH measurement is a critical requirement during labour and delivery. The intensive care of ill preterm babies involves provision of an optimal thermal environment and respiratory support. Monitoring of blood gas and acid-base status is essential, and this involves both blood sampling for in vitro analysis as well as the use of invasive or non-invasive sensors. For the future it will be vital that the technologies used are subjected to controlled trials to establish benefit or otherwise.

  20. The Use of Fetal Noninvasive Electrocardiography.

    Science.gov (United States)

    Lakhno, Igor

    2016-01-01

    Preeclampsia (PE) is one of the severe complications of pregnancy that leads to fetal deterioration. The aim was to survey the validity of fetal distress diagnostics in case of Doppler ultrasonic umbilical vein and arteries blood flow velocity investigation and ECG parameters analysis obtained from maternal abdominal signal before labor in preeclamptic patients. Fetal noninvasive ECG and umbilical arterial and venous Doppler investigation were performed in 120 patients at 34-40 weeks of gestation. And 30 of them had physiological gestation and were involved in Group I. In Group II 52 pregnant women with mild-moderate PE were observed. 38 patients with severe PE were monitored in Group III. The most considerable negative correlation was determined in pair Apgar score 1 versus T/QRS (R = -0.50; p < 0.05). So the increased T/QRS ratio was the most evident marker of fetal distress. Fetal noninvasive ECG showed sensitivity of 96.6% and specificity of 98.4% and, therefore, was determined as more accurate method for fetal monitoring.

  1. Fetal ventriculomegaly: Diagnosis, treatment, and future directions.

    Science.gov (United States)

    Pisapia, Jared M; Sinha, Saurabh; Zarnow, Deborah M; Johnson, Mark P; Heuer, Gregory G

    2017-07-01

    Fetal ventriculomegaly (VM) refers to the enlargement of the cerebral ventricles in utero. It is associated with the postnatal diagnosis of hydrocephalus. VM is clinically diagnosed on ultrasound and is defined as an atrial diameter greater than 10 mm. Because of the anatomic detailed seen with advanced imaging, VM is often further characterized by fetal magnetic resonance imaging (MRI). Fetal VM is a heterogeneous condition with various etiologies and a wide range of neurodevelopmental outcomes. These outcomes are heavily dependent on the presence or absence of associated anomalies and the direct cause of the ventriculomegaly rather than on the absolute degree of VM. In this review article, we discuss diagnosis, work-up, counseling, and management strategies as they relate to fetal VM. We then describe imaging-based research efforts aimed at using prenatal data to predict postnatal outcome. Finally, we review the early experience with fetal therapy such as in utero shunting, as well as the advances in prenatal diagnosis and fetal surgery that may begin to address the limitations of previous therapeutic efforts.

  2. Fetal growth potential and pregnancy outcome.

    Science.gov (United States)

    Bukowski, Radek

    2004-02-01

    Although the association of fetal growth restriction and adverse pregnancy outcomes is well known, lack of sensitivity limits its clinical value. To a large extent, this limitation is a result of traditionally used method to define growth restriction by comparing fetal or birth weight to population norms. The use of population norms, by virtue of their inability to fully consider individual variation, results in high false positive and negative rates. An alternative, calculating fetal individually optimal growth potential, based on physiological determinants of individual growth, is superior in predicting adverse outcomes of pregnancy. Impairment of fetal growth potential identifes some adverse pregnancy outcomes that are not associated with growth restrction defined by population norms. When compared with traditional population-based norms, fetal growth potential is a better predictor of several important adverse outcomes of pregnancy which include: stillbirth, neonatal mortality and morbidity, and long-term adverse neonatal outcomes like neonatal encephalopathy, cerebral palsy and cognitive abilities. Impairment of individual growth potential is also strongly associated with spontaneous preterm delivery. Although definitive interventional trials have not been conducted as yet to validate the clinical value of fetal growth potential, many observational studies, conducted in various populations, indicate its significant promise in this respect.

  3. The Use of Fetal Noninvasive Electrocardiography

    Directory of Open Access Journals (Sweden)

    Igor Lakhno

    2016-01-01

    Full Text Available Preeclampsia (PE is one of the severe complications of pregnancy that leads to fetal deterioration. The aim was to survey the validity of fetal distress diagnostics in case of Doppler ultrasonic umbilical vein and arteries blood flow velocity investigation and ECG parameters analysis obtained from maternal abdominal signal before labor in preeclamptic patients. Fetal noninvasive ECG and umbilical arterial and venous Doppler investigation were performed in 120 patients at 34–40 weeks of gestation. And 30 of them had physiological gestation and were involved in Group I. In Group II 52 pregnant women with mild-moderate PE were observed. 38 patients with severe PE were monitored in Group III. The most considerable negative correlation was determined in pair Apgar score 1 versus T/QRS (R=-0.50; p<0.05. So the increased T/QRS ratio was the most evident marker of fetal distress. Fetal noninvasive ECG showed sensitivity of 96.6% and specificity of 98.4% and, therefore, was determined as more accurate method for fetal monitoring.

  4. Maternal feeding controls fetal biological clock.

    Directory of Open Access Journals (Sweden)

    Hidenobu Ohta

    Full Text Available BACKGROUND: It is widely accepted that circadian physiological rhythms of the fetus are affected by oscillators in the maternal brain that are coupled to the environmental light-dark (LD cycle. METHODOLOGY/PRINCIPAL FINDINGS: To study the link between fetal and maternal biological clocks, we investigated the effects of cycles of maternal food availability on the rhythms of Per1 gene expression in the fetal suprachiasmatic nucleus (SCN and liver using a transgenic rat model whose tissues express luciferase in vitro. Although the maternal SCN remained phase-locked to the LD cycle, maternal restricted feeding phase-advanced the fetal SCN and liver by 5 and 7 hours respectively within the 22-day pregnancy. CONCLUSIONS/SIGNIFICANCE: Our results demonstrate that maternal feeding entrains the fetal SCN and liver independently of both the maternal SCN and the LD cycle. This indicates that maternal-feeding signals can be more influential for the fetal SCN and particular organ oscillators than hormonal signals controlled by the maternal SCN, suggesting the importance of a regular maternal feeding schedule for appropriate fetal molecular clockwork during pregnancy.

  5. Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.

    Science.gov (United States)

    Workie, Fegegta A; Rais-Bahrami, K; Short, Billie L

    2005-10-01

    Continuous monitoring by pulse oximetry is a common practice for preterm and critically ill newborns. A new generation of motion-tolerant pulse oximeters have been designed for improved clinical performance with a substantial reduction in alarm frequency. However, little is known about the differences among these new-generation pulse oximeters in the neonatal intensive care unit (NICU). The purpose of this study is to assess the clinical performance of two new-generation pulse oximeters in the NICU. Two new-generation pulse oximeters were used simultaneously to monitor 36 patients in the NICU. The two devices studied were the Philips FAST and the Masimo SET. Patients were randomly assigned for their digit selection and data were collected only when waveforms were of good quality and/or the pulse oximeter's pulse rate (PR) correlated with the electrocardiogram heart rate (HR). The data for oxygen saturation measurements, number of true and false alarms, and number of dropouts as well as the duration of dropouts for each pulse oximeter were recorded by the primary investigator at 5-minute intervals for a period of 2 hours on each patient. Dropouts are instances when the pulse oximeter alarm sounds due to its inability to identify the arterial pulse and provide an oxygen saturation reading. The mean gestational age for the study group was 32 weeks (rang, 24 to 42 weeks). Repeated-measures analysis of variance indicated no difference between the two devices across all time measurements (p=0.357). In addition, paired t-tests for true alarms and false alarms were not significant, with p-values of 0.151 and 0.869, respectively. There was a difference in the number of data dropouts (pMasimo 38). The duration of dropouts was also significant; the Philips device had three times longer duration of dropouts. Physiologic monitoring in the critical care setting requires accurate data measurements. The two new-generation pulse oximeters, the Philips FAST and Masimo SET, are

  6. Bloqueio AV total congênito: novo modelo experimental para avaliação do marcapasso fetal Fetal heart block: a new experimental model to assess fetal pacing

    Directory of Open Access Journals (Sweden)

    Renato S Assad

    1994-09-01

    . The acute stimulation thresholds were consistently low for both the leads, with lower values for the screw-in lead at pulse duration below 0.9 ms (p 0.20 were found in R-wave amplitude between the two electrodes. Slew rates were significantly higher with the screw-in group than with the stitch-on group (1.40 ± 0.2 versus 0.62 ± 0.2 V/s, p=0.04. This model of CHB is a simple and reproducible method to assess fetal pacing. We find the screw-in electrode a better option when fetal pacing is indicated.

  7. High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus

    Energy Technology Data Exchange (ETDEWEB)

    Yamamura, Jin; Frisch, Michael; Adam, Gerhard; Wedegaertner, Ulrike [University Hospital Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schnackenburg, Bernhard; Kooijmann, Hendrik [Philips Medical Systems, Hamburg (Germany); Hecher, Kurt [University Hospital Hamburg-Eppendorf, Department of Obstetrics and Fetal Medicine, Hamburg (Germany)

    2009-10-15

    The aim of this study was to perform fetal cardiac magnetic resonance imaging (MRI) with triggering of the fetal heart beat in utero in a sheep model. All experimental protocols were reviewed and the usage of ewes and fetuses was approved by the local animal protection authorities. Images of the hearts of six pregnant ewes were obtained by using a 1.5-T MR system (Philips Medical Systems, Best, Netherlands). The fetuses were chronically instrumented with a carotid catheter to measure the fetal heart frequency for the cardiac triggering. Pulse wave triggered, breath-hold cine-MRI with steady-state free precession (SSFP) was achieved in short axis, two-, four- and three-chamber views. The left ventricular volume and thus the function were measured from the short axis. The fetal heart frequencies ranged between 130 and 160 bpm. The mitral, tricuspid, aortic, and pulmonary valves could be clearly observed. The foramen ovale could be visualized. Myocardial contraction was shown in cine sequences. The average blood volume at the end systole was 3.4{+-}0.2 ml ({+-} SD). The average volume at end diastole was 5.2{+-}0.2 ml; thus the stroke volumes of the left ventricle in the systole were between 1.7 and 1.9 ml with ejection fractions of 38.6% and 39%, respectively. The pulse wave triggered cardiac MRI of the fetal heart allowed evaluation of anatomical structures and functional information. This feasibility study demonstrates the applicability of MRI for future evaluation of fetuses with complex congenital heart defects, once a noninvasive method has been developed to perform fetal cardiac triggering. (orig.)

  8. Neurodevelopmental changes of fetal pain.

    Science.gov (United States)

    Lowery, Curtis L; Hardman, Mary P; Manning, Nirvana; Hall, R Whit; Anand, K J S; Clancy, Barbara

    2007-10-01

    Pain in the developing fetus is controversial because of the difficulty in measuring and interpreting pain during gestation. It has received increased attention lately because of recently introduced legislation that would require consideration of fetal pain during intentional termination of pregnancy. During development, sensory fibers are abundant by 20 weeks; a functional spinal reflex is present by 19 weeks; connections to the thalamus are present by 20 weeks; and connections to subplate neurons are present by 17 weeks with intensive differentiation by 25 weeks. These cells are important developmentally, but decline as a result of natural apoptosis. Mature thalamocortical projections are not present until 29 to 30 weeks, which has led many to believe the fetus does not experience emotional "pain" until then. Pain requires both nociception and emotional reaction or interpretation. Nociception causes physiologic stress, which in turn causes increases in catecholamines, cortisol, and other stress hormones. Physiological stress is different from the emotional pain felt by the more mature fetus or infant, and this stress is mitigated by pain medication such as opiates. The plasticity of the developing brain makes it vulnerable to the stressors that cause long-term developmental changes, ultimately leading to adverse neurological outcomes. Whereas evidence for conscious pain perception is indirect, evidence for the subconscious incorporation of pain into neurological development and plasticity is incontrovertible. Scientific data, not religious or political conviction, should guide the desperately needed research in this field. In the meantime, it seems prudent to avoid pain during gestation.

  9. Fetal and neonatal endocrine disruptors.

    Science.gov (United States)

    Unüvar, Tolga; Büyükgebiz, Atilla

    2012-06-01

    Endocrine disruptors are substances commonly encountered in every setting and condition in the modern world. It is virtually impossible to avoid the contact with these chemical compounds in our daily life. Molecules defined as endocrine disruptors constitute an extremely heterogeneous group and include synthetic chemicals used as industrial solvents/lubricants and their by-products. Natural chemicals found in human and animal food (phytoestrogens) also act as endocrine disruptors. Different from adults, children are not exposed only to chemical toxins in the environment but may also be exposed during their intrauterine life. Hundreds of toxic substances, which include neuro-immune and endocrine toxic chemical components that may influence the critical steps of hormonal, neurological and immunological development, may affect the fetus via the placental cord and these substances may be excreted in the meconium. Children and especially newborns are more sensitive to environmental toxins compared to adults. Metabolic pathways are immature, especially in the first months of life. The ability of the newborn to metabolize, detoxify and eliminate many toxins is different from that of the adults. Although exposures occur during fetal or neonatal period, their effects may sometimes be observed in later years. Further studies are needed to clarify the effects of these substances on the endocrine system and to provide evidence for preventive measures.

  10. Fetal echocardiography in ectopia cordis.

    Science.gov (United States)

    Repondek-Liberska, M; Janiak, K; Wloch, A

    2000-01-01

    Ectopia cordis is an extremely rare congenital abnormality occurring in 5.5 to 7.9 per 1 million live births with high lethality. Between January 1995 and October 1997 eight cases of ectopia cordis were diagnosed at our institute before birth. On the basis of echocardiography the fetal heart anatomy was categorized as either normal heart anatomy (NHA; n = 3) or congenital heart defect (CHD; n = 5). In the majority of cases (seven of eight) other abnormalities were present. Some reports have described ectopia cordis being diagnosed in the first trimester of pregnancy. In our study group the average gestational age at diagnosis was 26 weeks. The prenatal diagnosis of isolated ectopia cordis is easy; counseling the patient, the perinatal management including term, place, and method of delivery, and optimal care of the newborn are more difficult. Ectopia cordis is a malformation that pediatricians rarely encounter, even at pediatric cardiology centers. Much more frequently it is a problem for sonographers and obstetricians; however, pediatric cardiologists should be aware of diagnostic algorithm for such cases, especially when additional abnormalities are present.

  11. Radial pulse (image)

    Science.gov (United States)

    ... heart. The arteries are the vessels with the "pulse", a rhythmic pushing of the blood in the ... a refilling of the heart chamber. To determine heart rate, one feels the beats at a pulse point ...

  12. Wrist pulse (image)

    Science.gov (United States)

    To measure the pulse at the wrist, place the index and middle finger over the underside of the opposite wrist, below the base ... firmly with flat fingers until you feel the pulse in the radial artery.

  13. Masimo Rad-57 Pulse CO-Oximeter for noninvasive carboxyhemoglobin measurement.

    Science.gov (United States)

    Suner, Selim; McMurdy, John

    2009-03-01

    Noninvasive methods of body fluid chemical measurement have been expanding. New technologies are enabling the quantification of different compounds in the blood and interstitial tissues. One example of this is the pulse oximeter, which has facilitated the measurement of oxyhemoglobin rapidly and reliably without the requirement of blood-draws. The Masimo Rad-57 Pulse CO-Oximeter expanded the capabilities of pulse-oximetry to include measurements of carboxyhemoglobin and methemoglobin. This innovation has revolutionized the paradigm for detection of patients with CO poisoning. Previously, clinicians relied on historical information and patient signs and symptoms pointing to the possibility of CO exposure or toxicity. Only then would a blood test be ordered to measure carboxyhemoglobin levels. Since the presentation of CO poisoning is nonspecific and overlaps with many other conditions, and since the presence of environmental CO is often unknown, the detection of this condition was only possible in cases where the presence of CO was obvious or where the symptoms were severe. We now know, from studies conducted using the Rad-57, the only US FDA-approved device for noninvasive measurement of SpCO, that there are a significant number of patients who experience CO exposure but are nonsymptomatic. The Rad-57 provides a clinical justification for screening in the healthcare setting to identify patients with significant CO exposure who would otherwise be undetected.

  14. Pulse-Width Jitter Measurement for Laser Diode Pulses

    Institute of Scientific and Technical Information of China (English)

    TANG Jun-Hua; WANG Yun-Cai

    2006-01-01

    @@ Theoretical analysis and experimental measurement of pulse-width jitter of diode laser pulses are presented. The expression of pulse power spectra with all amplitude jitter, timing jitter and pulse-width jitter is deduced.

  15. Continuous fetal tissue pH measurement in labor.

    Science.gov (United States)

    Young, B K; Noumoff, J; Klein, S A; Katz, M

    1978-11-01

    Fifty-one women in labor had continuous monitoring of fetal scalp tissue pH, fetal heart rate by ECG, and uterine contractions. A miniature pH electrode secured by a double spiral fetal ECG electrode was used for measurement of fetal pH every 15 seconds. The results were correlated with fetal scalp blood pH values obtained simultaneously. Fetal scalp sampling is intermittent, requires repeated scalp incisions, is subject to errors due to air mixing and coagulation of the blood sample, and is uncomfortable for the parturient. Placement of the tissue pH electrode allows continuous data recording with the minimum discomfort to the patient and the least number of fetal scalp incisions. Clinical use of the tissue pH electrode might be a practical alternative to fetal scalp samples, if the data obtained accurately reflect fetal status.

  16. Role of fetal monitoring in high risk pregnancy by fetal electrocardiogram

    Directory of Open Access Journals (Sweden)

    Somya Girish Goyal

    2014-08-01

    Full Text Available Background: Non-stress test is an external monitoring of fetal heart rate by electrocardiograph. Although intermittent auscultation of fetal heart rate is equivalent to continuous electronic fetal monitoring in detecting fetal compromise1 but continuous electronic fetal monitoring is indicated in high risk patients women whose foetuses are at high risk for neonatal encephalopathy or cerebral palsy.2 Objective of current study was to study the efficacy and diagnostic value of non-stress Test for surveillance and its usefulness to detect fetal distress at early stage which help to decide further management in mode of delivery. Methods: Design: prospective study. NST was done in 50 high risk patients for minimum of 20 minutes and in patients with non-reactive non stress test it was continued for 40 minutes. Maternal age, parity, complications during labour, and delivery, mode of delivery, indications of caesarean section and perinatal outcome were noted. Results: Out of total 50 cases studied patient delivered vaginally were 24 and Caesarean was done in 26 cases. Most LSCS were performed due to PIH (35% and related complications like IUGR, eclampsia (10%, fetal distress, previous caesarean pregnancy, IUGR, oligohydraminos and meconium stained liquor. 52% patients were delivered by caesarean and 48% by normal delivery. Conclusions: Routine use of electronic fetal heart monitoring helped in reduction of neonatal morbidity and mortality with increased rate of caesarean section. [Int J Reprod Contracept Obstet Gynecol 2014; 3(4.000: 893-897

  17. Evaluation of the fetal QT interval using non-invasive fetal ECG technology.

    Science.gov (United States)

    Behar, Joachim; Zhu, Tingting; Oster, Julien; Niksch, Alisa; Mah, Douglas Y; Chun, Terrence; Greenberg, James; Tanner, Cassandre; Harrop, Jessica; Sameni, Reza; Ward, Jay; Wolfberg, Adam J; Clifford, Gari D

    2016-09-01

    Non-invasive fetal electrocardiography (NI-FECG) is a promising alternative continuous fetal monitoring method that has the potential to allow morphological analysis of the FECG. However, there are a number of challenges associated with the evaluation of morphological parameters from the NI-FECG, including low signal to noise ratio of the NI-FECG and methodological challenges for getting reference annotations and evaluating the accuracy of segmentation algorithms. This work aims to validate the measurement of the fetal QT interval in term laboring women using a NI-FECG electrocardiogram monitor. Fetal electrocardiogram data were recorded from 22 laboring women at term using the NI-FECG and an invasive fetal scalp electrode simultaneously. A total of 105 one-minute epochs were selected for analysis. Three pediatric electrophysiologists independently annotated individual waveforms and averaged waveforms from each epoch. The intervals measured on the averaged cycles taken from the NI-FECG and the fetal scalp electrode showed a close agreement; the root mean square error between all corresponding averaged NI-FECG and fetal scalp electrode beats was 13.6 ms, which is lower than the lowest adult root mean square error of 16.1 ms observed in related adult QT studies. These results provide evidence that NI-FECG technology enables accurate extraction of the fetal QT interval.

  18. The number of fetal cells in maternal blood is associated to exercise and fetal gender

    DEFF Research Database (Denmark)

    Schlütter, Jacob Mørup; Kirkegaard, Ida; Christensen, Connie Britta;

    were then stained with a cocktail of fetal cell-specific antibodies, identified and counted. Results: Participants carrying male fetuses had higher median number of fcmbs per 30 mL blood than those carrying female fetuses (5 vs. 3, p=0.004). Exercise within 3 hours (1.5 vs. 4, p=0.02) and 24 hours (2......Introduction: We have established a robust method to specifically identify and isolate a placental fetal cell in maternal blood (fcmbs) at a gestational age of 12 weeks. The concentration of these cells, however, varies considerably among pregnant women (median 3 fcmbs/30 mL blood, range 0...... activity was obtained by a questionnaire and a structured interview. The number of fcmbs was assessed in 30 mL blood processed by a proprietary method developed in-house. Fetal cells in the blood, binding to fetal cell specific antibodies, were initially isolated by magnetic cell sorting. The fetal cells...

  19. FETAL ECHOCARDIOGRAPHY: A STUDY OF CLINICAL OUTCOME

    Directory of Open Access Journals (Sweden)

    Rajanish

    2014-01-01

    Full Text Available BACKGROUND : S tructural abnormalities of the heart and great vessels are fairly common congenital lab normalities with the incidenceof8 in 1000 live births. With the advent of real time scanners fetal cardia can atomy can be analyze d echocardiographically. The earlier diagnosis will make an impact on clinical management of fetus with congenital heart disease. It helps intimely triage and optimal management of specific congenital heart disease either structural , functional orarrhythmia . OBJECTIVES : This study was conducted to note the spectrum of congenital heart diseases detected on fetal echo in pregnant mothers referred with high risk for CHD sand to assess the outcome of prenatally detected congenital heart diseases. MATERIAL S AND METHODS : T he study is aprospective descriptive study conducted in a tertiary care pediatric hospital in Mumbai over period of one year . P regnant mothers were referred for fetal echo , where pregnancy was considered as high risk for CHDs due to maternal , fetalfactorsorabnormallevel 1 scan.Fetal echowas performed by a trained pediatric cardiologistat 18 to 20 week of gestation using HP sonos 2000 echocardiographicmachinewith3/3.5 Hz transducer. Cardiac lesionsandoutcome of pregnancy was noted by postnatal follow - up of patients. RESULTS : A total of 170 patients underwent fetal echo , 13 patients have not delivered and 48 were lost to follow - up. Fetal echo was normal in 130(76.4% and abnormalities were detected in 40(23.5%.Structural anomalies were seen in 24(14.1% , arrhythmia in 5(2.9% and functional abnormalities in 11(6.4%.On outcome analysis84 (77.1% arealive , IUD /terminationof pregnancyoccurred in 18(16.5% , neonatal death in 6 (5.5% , infant death in 1 (0.9%. CONCLUSIONS : All ranges of CHDs can be diagnosed by fetal echocardiography . O utcome of prenatally detected complex congenital heart disease is poor ; nonetheless earlier detection provides a n opportunity for early interventions and

  20. [Biomechanical characteristics of human fetal membranes. Preterm fetal membranes are stronger than term fetal membranes].

    Science.gov (United States)

    Rangaswamy, N; Abdelrahim, A; Moore, R M; Uyen, L; Mercer, B M; Mansour, J M; Kumar, D; Sawady, J; Moore, J J

    2011-06-01

    The purpose of this study was to determine the biomechanical characteristics of human fetal membranes (FM) throughout gestation. Biomechanical properties were determined for 115 FM of 23-41 weeks gestation using our previously described methodology. The areas of membrane immediately adjacent to the strongest and weakest tested spots were sampled for histomorphometric analysis. Clinical data on the patients whose FM were examined were also collected. FM less than 28 weeks gestation were associated with higher incidence of abruption and chorioamnionitis. Topographically FM at all gestations had heterogeneous biomechanical characteristics over their surfaces with distinct weak areas. The most premature membranes were the strongest. FM strength represented by rupture force and work to rupture decreased with increasing gestation in both weak and strong regions of FM. This decrease in FM strength was most dramatic at more than 38 weeks gestation. The FM component amnion-chorion sublayers were thinner in the weak areas compared to strong areas. Compared to term FM, preterm FM are stronger but have similar heterogeneous weak and strong areas. Following a gradual increase in FM weakness with increasing gestation, there is a major drop-off at term 38 weeks gestation. The FM weak areas are thinner than the stronger areas. Whether the difference in thickness is enough to account for the strength differences is unknown.

  1. Boy or Girl? Maternal Psychological Correlates of Knowing Fetal Sex.

    Science.gov (United States)

    Kotila, Letitia E; Schoppe-Sullivan, Sarah J; Kamp Dush, Claire M

    2014-10-01

    Ultrasound provides a reliable, convenient way to determine fetal sex, but not all expectant mothers pursue this knowledge. We used logistic regression to investigate whether maternal personality, parenting perfectionism, and gender role beliefs were associated with knowing fetal sex in a recent sample of first-time expectant mothers. We also tested whether conscientiousness and extraversion moderated the association between gender role beliefs and knowing fetal sex. Mothers who were more open to experience were less likely to know fetal sex, whereas mothers high in parenting perfectionism were more likely to know fetal sex. Conscientious mothers who espoused more egalitarian gender role beliefs were less likely to know fetal sex.

  2. Occupational lifting, fetal death and preterm birth

    DEFF Research Database (Denmark)

    Mocevic, Emina; Svendsen, Susanne Wulff; Jørgensen, Kristian Tore

    2014-01-01

    OBJECTIVE: We examined the association between occupational lifting during pregnancy and risk of fetal death and preterm birth using a job exposure matrix (JEM). METHODS: For 68,086 occupationally active women in the Danish National Birth Cohort, interview information on occupational lifting...... the JEM. We used Cox regression models with gestational age as underlying time variable and adjustment for covariates. RESULTS: We observed 2,717 fetal deaths and 3,128 preterm births within the study cohort. No exposure-response relation was observed for fetal death, but for women with a prior fetal...... death, we found a hazard ratio (HR) of 2.87 (95% CI 1.37, 6.01) for stillbirth (fetal death ≥22 completed gestational weeks) among those who lifted >200 kg/day. For preterm birth, we found an exposure-response relation for primigravid women, reaching a HR of 1.43 (95% CI 1.13, 1.80) for total loads >200...

  3. Recent advances in fetal gene therapy.

    Science.gov (United States)

    Buckley, Suzanne M K; Rahim, Ahad A; Chan, Jerry K Y; David, Anna L; Peebles, Donald M; Coutelle, Charles; Waddingtont, Simon N

    2011-04-01

    Over the first decade of this new millennium gene therapy has demonstrated clear clinical benefits in several diseases for which conventional medicine offers no treatment. Clinical trials of gene therapy for single gene disorders have recruited predominantly young patients since older subjects may have suffered irrevocablepathological changes or may not be available because the disease is lethal relatively early in life. The concept of fetal gene therapy is an extension of this principle in that diseases in which irreversible changes occur at or beforebirth can be prevented by gene supplementation or repair in the fetus or associated maternal tissues. This article ccnsiders the enthusiasm and skepticism held for fetal gene therapy and its potential for clinical application. It coversa spectrum of candidate diseases for fetal gene therapy including Pompe disease, Gaucher disease, thalassemia, congenital protein C deficiency and cystic fibrosis. It outlines successful and not-so-successful examples of fetal gene therapy in animal models. Finally the application and potential of fetal gene transfer as a fundamental research tool for developmental biology and generation of somatic transgenic animals is surveyed.

  4. Magnetocardiography in the diagnosis of fetal arrhythmia.

    Science.gov (United States)

    van Leeuwen, P; Hailer, B; Bader, W; Geissler, J; Trowitzsch, E; Grönemeyer, D H

    1999-11-01

    To examine the possible use of magnetocardiography in the diagnosis of fetal arrhythmias. Investigation of routinely examined pregnant women, as well as women referred because of arrhythmias or other reasons. Sixty-three women between the 13th and 42nd week of pregnancy. Recording of 189 fetal magnetocardiograms, of which 173 traces (92%) demonstrated sufficient fetal signal strength to permit evaluation. After digital subtraction of the maternal artefact, all fetal complexes were identified and the recording was examined for arrhythmic events. Short bradycardic episodes, not associated with any pathological condition, were found in 26% of all recordings, usually in mid-pregnancy. In 12 cases, isolated extrasystoles of no clinical importance could be identified. There were nine traces which revealed multiple arrhythmias including ventricular and supraventricular ectopic beats, bigeminy and trigeminy, sino-atrial block and atrio-ventricular conduction disturbances. Furthermore, two cases with tachycardia were found. Magnetocardiography offers a simple noninvasive method for examination of the fetal cardiac electrophysiological signal. It may thus be useful in the identification and classification of clinically relevant arrhythmia and aid in decisions concerning treatment.

  5. Automatic real-time tracking of fetal mouth in fetoscopic video sequence for supporting fetal surgeries

    Science.gov (United States)

    Xu, Rong; Xie, Tianliang; Ohya, Jun; Zhang, Bo; Sato, Yoshinobu; Fujie, Masakatsu G.

    2013-03-01

    Recently, a minimally invasive surgery (MIS) called fetoscopic tracheal occlusion (FETO) was developed to treat severe congenital diaphragmatic hernia (CDH) via fetoscopy, by which a detachable balloon is placed into the fetal trachea for preventing pulmonary hypoplasia through increasing the pressure of the chest cavity. This surgery is so dangerous that a supporting system for navigating surgeries is deemed necessary. In this paper, to guide a surgical tool to be inserted into the fetal trachea, an automatic approach is proposed to detect and track the fetal face and mouth via fetoscopic video sequencing. More specifically, the AdaBoost algorithm is utilized as a classifier to detect the fetal face based on Haarlike features, which calculate the difference between the sums of the pixel intensities in each adjacent region at a specific location in a detection window. Then, the CamShift algorithm based on an iterative search in a color histogram is applied to track the fetal face, and the fetal mouth is fitted by an ellipse detected via an improved iterative randomized Hough transform approach. The experimental results demonstrate that the proposed automatic approach can accurately detect and track the fetal face and mouth in real-time in a fetoscopic video sequence, as well as provide an effective and timely feedback to the robot control system of the surgical tool for FETO surgeries.

  6. The relationship between maternal and fetal vitamin D, insulin resistance, and fetal growth.

    LENUS (Irish Health Repository)

    Walsh, Jennifer M

    2013-05-01

    Evidence for a role of vitamin D in maintaining normal glucose homeostasis is inconclusive. We sought to clarify the relationship between maternal and fetal insulin resistance and vitamin D status. This is a prospective cohort study of 60 caucasian pregnant women. Concentrations of 25-hydroxyvitamin D (25-OHD), glucose, insulin, and leptin were measured in early pregnancy and at 28 weeks. Ultrasound at 34 weeks assessed fetal anthropometry including abdominal wall width, a marker of fetal adiposity. At delivery birth weight was recorded and fetal 25-OHD, glucose, C-peptide, and leptin measured in cord blood. Insulin resistance was calculated using the Homeostasis Model Assessment (HOMA) equation. We found that those with lower 25-OHD in early pregnancy had higher HOMA indices at 28 weeks, (r = -.32, P = .02). No significant relationship existed between maternal or fetal leptin and 25-OHD, or between maternal or fetal 25-OHD and fetal anthropometry or birth weight. The incidence of vitamin D deficiency was high at each time point (15%-45%). These findings lend support to routine antenatal supplementation with vitamin D in at risk populations.

  7. New advances in fetal MR neuroimaging

    Energy Technology Data Exchange (ETDEWEB)

    Garel, Catherine [Hopital Robert Debre, Department of Paediatric Imaging, Paris (France)

    2006-07-15

    MR is now routinely and widely used in fetal neuroimaging and has proven to be valuable in the detection of many cerebral lesions, either genetically determined or acquired in utero. However, its efficiency has certain limits in the detection of diffuse white-matter abnormalities, the evaluation of fibre development and the demonstration of metabolic disorders. Moreover, conventional fetal MR imaging provides only a morphological approach to the fetal brain. New techniques such as diffusion-weighted imaging, diffusion tensor imaging, proton MR spectroscopy and functional MR imaging are developing. The majority of these are not used routinely. The principles, aims, technical problems and possible applications of these techniques for imaging the fetus are discussed. (orig.)

  8. Mechanisms of Fetal Programming in Hypertension

    Directory of Open Access Journals (Sweden)

    John Edward Jones

    2012-01-01

    Full Text Available Events that occur in the early fetal environment have been linked to long-term health and lifespan consequences in the adult. Intrauterine growth restriction (IUGR, which may occur as a result of nutrient insufficiency, exposure to hormones, or disruptions in placental structure or function, may induce the fetus to alter its developmental program in order to adapt to the new conditions. IUGR may result in a decrease in the expression of genes that are responsible for nephrogenesis as nutrients are rerouted to the development of more essential organs. Fetal survival under these conditions often results in low birth weight and a deficit in nephron endowment, which are associated with hypertension in adults. Interestingly, male IUGR offspring appear to be more severely affected than females, suggesting that sex hormones may be involved. The processes of fetal programming of hypertension are complex, and we are only beginning to understand the underlying mechanisms.

  9. Rapidly Regressive Unilateral Fetal Pleural Effusion

    Directory of Open Access Journals (Sweden)

    Tuncay Yuce

    2015-03-01

    Full Text Available Intrauterine pleural effusion of fetal lungs rarely regresses without intervention. In our case we treated a women at 32th weeks of gestation. Her pregnancy was complicated with fetal pleural effusion and polyhydramniosis. A therapeutic thoracocentesis was planned and she received two courses of betamethasone prior to procedure. On the day of planned procedure, a substantial regression of pleural effusion was observed and procedure was postponed. During her antenatal follow-up a complete regression of pleural effusion was observed. After delivery pleural effusion did not relapse. These findings hint there may be a role of antenatal steroids in treatment of fetal pleural effusion, which is known to be resistant to treatment modalities both during antenatal and postnatal period. [Cukurova Med J 2015; 40(Suppl 1: 25-28

  10. Physiology of the fetal and transitional circulation.

    Science.gov (United States)

    Finnemore, Anna; Groves, Alan

    2015-08-01

    The fetal circulation is an entirely transient event, not replicated at any point in later life, and functionally distinct from the pediatric and adult circulations. Understanding of the physiology of the fetal circulation is vital for accurate interpretation of hemodynamic assessments in utero, but also for management of circulatory compromise in premature infants, who begin extrauterine life before the fetal circulation has finished its maturation. This review summarizes the key classical components of circulatory physiology, as well as some of the newer concepts of physiology that have been appreciated in recent years. The immature circulation has significantly altered function in all aspects of circulatory physiology. The mechanisms and significance of these differences are also discussed, as is the impact of these alterations on the circulatory transition of infants born prematurely.

  11. Effect of Placenta Previa on Fetal Growth

    Science.gov (United States)

    HARPER, Lorie M.; ODIBO, Anthony O.; MACONES, George A.; CRANE, James P.; CAHILL, Alison G.

    2011-01-01

    Objective To estimate the association between placenta previa and abnormal fetal growth. Study Design Retrospective cohort study of consecutive women undergoing ultrasound between 15–22 weeks. Groups were defined by the presence or absence of complete or partial placenta previa. The primary outcome was intrauterine growth restriction (IUGR), defined as a birth weight placenta previa on fetal growth restriction. Results Of 59,149 women, 724 (1.2%) were diagnosed with a complete or partial previa. After adjusting for significant confounding factors (black race, gestational diabetes, preeclampsia, and single umbilical artery,), the risk of IUGR remained similar (adjusted odds ratio 1.1, 95% CI 0.9–1.5). The presence of bleeding did not impact the risk of growth restriction. Conclusion Placenta previa is not associated with fetal growth restriction. Serial growth ultrasounds are not indicated in patients with placenta previa. PMID:20599185

  12. Role of fetal surgery in spinal dysraphism

    Directory of Open Access Journals (Sweden)

    A Martina Messing-Jünger

    2013-01-01

    Full Text Available Open spinal dysraphism is a common and clinically challenging organo-genetic malformation. Due to the well-known multi-organ affection with significant implication on the lives of patients and their families, abortion after prenatal diagnosis became reality in most parts of the world. After publication of the Management of Myelomeningocele Study (MOMS results fetal surgery seems to be a new option and a broad discussion arose regarding advantages and risks of in utero treatment of spina bifida. This paper tries to evaluate objectively the actual state of knowledge and experience. This review article gives a historical overview as well as the experimental and pathophysiological background of fetal surgery in open spinal dysraphism. Additionally clinical follow-up experience of foetoscopically treated patients are presented and discussed. After carefully outweighing all available information on fetal surgery for spina bifida, one has to conclude, in accordance with the MOMS investigators, that in utero surgery cannot be considered a standard option at present time. But there is clear evidence of the hypothesis that early closure of the spinal canal has a positive influence on spinal cord function and severity of Chiari malformation type II, has been proven. A persisting problem is the fetal risk of prematurity and the maternal risk of uterus damage. There is also evidence that due to technical restrictions, fetal closure of the spinal canal bears unsolved problems leading to a higher postnatal incidence of complication surgery. Finally, missing long-term results make a definite evaluation impossible so far. At the moment, fetal surgery in open spinal dysraphism is not a standard of care despite promising results regarding central nervous system protection due to early spinal canal closure. Many technical problems need to be solved in the future in order to make this option a safe and standard one.

  13. Fetal control of parturition in marsupials.

    Science.gov (United States)

    Shaw, G; Renfree, M B

    2001-01-01

    Among marsupials, the control of birth is best understood in the tammar wallaby. The young is tiny relative to the mother and is highly altricial. Adult female tammar wallabies weigh 5 kg, whereas the neonate weighs about 400 mg. However, despite this small size, there is clear evidence that the fetus provides the signal that sets the timing of birth through several mechanisms. A fetal signal activates a nitric oxide-guanylate cyclase system in the myometrium that may maintain myometrial inactivity, and this is down-regulated at term. There is also up-regulation of prostaglandin (PG) production in the gravid endometrium during the last two days of gestation that parallels increased placental PG synthesis, and a pregnancy-specific up-regulation of oxytocin receptors in the gravid myometrium that increases the responsiveness of the gravid uterus to mesotocin. These changes facilitate parturition, but an acute fetus-derived signal appears to trigger parturition. The fetal signal is probably related to glucocorticoid production. The fetal adrenal matures and is able to synthesize cortisol by Day 22 of the 26-day gestation. The fetal adrenals double in size between Day 24 and term, and their cortisol content increases over 10-fold. The pituitary of the neonate contains presumptive corticotrophs, and the adrenals increase cortisol production in response to adrenocorticotrophin. Prostaglandin E2, which is produced by the placenta, is also a potent stimulant of fetal adrenal cortisol synthesis. Treatment of tammars in late gestation with the cortisol agonist, dexamethasone, triggers birth around 23 h later. There is thus a strong case that fetal adrenal cortisol plays a key role in the preparation for birth and the timing of it. Further studies are in progress to more clearly define the mechanisms behind these actions of cortisol.

  14. Rheology of fetal and maternal blood.

    Science.gov (United States)

    Reinhart, W H; Danoff, S J; King, R G; Chien, S

    1985-01-01

    Rheological parameters were measured in 10 pairs of mothers and newborns. Whole blood viscosity was similar despite a higher fetal hematocrit (47.0 +/- 5.1 versus 35.5 +/- 12.0%, mean +/- SD, p less than 0.05). When the hematocrit of the suspension of red cells in plasma was adjusted to 45%, the viscosity was significantly lower in the fetal blood over a wide range of shear rates (0.52-208 S-1). The main reason for the lower viscosity in the fetal blood was the lower plasma viscosity as compared to the maternal blood (1.08 +/- 0.05 versus 1.37 +/- 0.08 centipoise, p less than 0.05); this in turn was attributable to a lower total plasma protein concentration (4.74 +/- 0.71 versus 6.47 +/- 0.64 g/dl, p less than 0.05). All protein fractions were lower in the fetal plasma. The assessment of red cell deformability by filtration through polycarbonate sieves revealed that the resistance of a fetal red cell was three times higher than that of a maternal red cell in a 2.6-micron pore, but there was no significant difference in resistance for these red cells in 6.9-micron pores. This higher filtration resistance of fetal red cells through the small pores was mainly due to their large volume (115.4 +/- 10.8 versus 93.5 +/- 5.9 fl, p less than 0.001). Measurements on membrane-free hemoglobin solutions indicated that the internal viscosity of these two types of red cells was not different.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. ACMG statement on noninvasive prenatal screening for fetal aneuploidy.

    Science.gov (United States)

    Gregg, Anthony R; Gross, S J; Best, R G; Monaghan, K G; Bajaj, K; Skotko, B G; Thompson, B H; Watson, M S

    2013-05-01

    Noninvasive assessment of the fetal genome is now possible using next-generation sequencing technologies. The isolation of fetal DNA fragments from maternal circulation in sufficient quantity and sizes, together with proprietary bioinformatics tools, now allows patients the option of noninvasive fetal aneuploidy screening. However, obstetric care providers must become familiar with the advantages and disadvantages of the utilization of this approach as analysis of cell-free fetal DNA moves into clinical practice. Once informed, clinicians can provide efficient pretest and posttest counseling with the goal of avoiding patient harm. It is in the public's best interest that test results contain key elements and that laboratories adhere to established quality control and proficiency testing standards. The analysis of cell-free fetal DNA in maternal circulation for fetal aneuploidy screening is likely the first of major steps toward the eventual application of whole fetal genome/whole fetal exome sequencing.

  16. Scientific and ethical perspectives of perinatal and fetal medicine

    National Research Council Canada - National Science Library

    Valdés R, Enrique; Soto-Chacón, Emiliano; Castillo T, Silvia

    2008-01-01

    ..., called Perinatal and Fetal Medicine. We discuss the possible role of fetal cells and DNA in the diagnosis and treatment of diseases in the intrauterine environment The associated bioethical issues associated to these medical actions...

  17. Fetal responses to induced maternal relaxation during pregnancy

    Science.gov (United States)

    DiPietro, Janet A.; Costigan, Kathleen A.; Nelson, Priscilla; Gurewitsch, Edith D.; Laudenslager, Mark L.

    2008-01-01

    Fetal responses to induced maternal relaxation during the 32nd week of pregnancy were recorded in 100 maternal-fetal pairs using a digitized data collection system. The 18-minute guided imagery relaxation manipulation generated significant changes in maternal heart rate, skin conductance, respiration period, and respiratory sinus arrhythmia. Significant alterations in fetal neurobehavior were observed, including decreased fetal heart rate (FHR), increased FHR variability, suppression of fetal motor activity (FM), and increased FM-FHR coupling. Attribution of the two fetal cardiac responses to the guided imagery procedure itself, as opposed to simple rest or recumbency, is tempered by the observed pattern of response. Evaluation of correspondence between changes within individual maternal-fetal pairs revealed significant associations between maternal autonomic measures and fetal cardiac patterns, lower umbilical and uterine artery resistance and increased FHR variability, and declining salivary cortisol and FM activity. Potential mechanisms that may mediate the observed results are discussed. PMID:17919804

  18. In utero MRI diagnosis of fetal malformations in oligohydramnios

    Directory of Open Access Journals (Sweden)

    Ahmed Hesham Said

    2016-12-01

    Conclusion: MRI is valuable in evaluating suspected fetal malformations especially those related to brain and urinary system when ultrasound is inconclusive owing to oligohydramnios. Fetal MRI can add findings that may modify prenatal diagnosis.

  19. [Fetal pain: immediate and long term consequences].

    Science.gov (United States)

    Houfflin Debarge, Véronique; Dutriez, Isabelle; Pusniak, Benoit; Delarue, Eléonore; Storme, Laurent

    2010-06-01

    Several situations are potentially painful for fetuses, such as malformations and invasive procedures. Nociceptive pathways are known to be functional at 26 weeks. Even if it is not possible to evaluate the fetal experience of pain, it is essential to examine its immediate and long-term consequences. As early as the beginning of the second trimester, hemodynamic and hormonal responses are observed following fetal nociceptive stimulation, In experimental studies, long-term changes have been noted in the corticotrop axis, subsequent responses to pain, and behavior after perinatal nociceptive stimulation.

  20. Tumours of the fetal body: a review

    Energy Technology Data Exchange (ETDEWEB)

    Avni, Fred E.; Massez, Anne; Cassart, Marie [University Clinics of Brussels - Erasme Hospital, Department of Medical Imaging, Brussels (Belgium)

    2009-11-15

    Tumours of the fetal body are rare, but lesions have been reported in all spaces, especially in the mediastinum, the pericardial space, the adrenals, the kidney, and the liver. Lymphangioma and teratoma are the commonest histological types encountered, followed by cardiac rhabdomyoma. Adrenal neuroblastoma is the commonest malignant tumour. Imaging plays an essential role in the detection and work-up of these tumours. In addition to assisting clinicians it also helps in counselling parents. Most tumours are detected by antenatal US, but fetal MRI is increasingly used as it brings significant additional information in terms of tumour extent, composition and complications. (orig.)

  1. Pontomedullary disconnection: fetal and neonatal considerations

    Energy Technology Data Exchange (ETDEWEB)

    McCann, Emma; Sweeney, Elizabeth [Royal Liverpool Children' s Hospital, Department of Clinical Genetics, Liverpool (United Kingdom); Pilling, David [Royal Liverpool Children' s Hospital, Department of Paediatric Radiology, Liverpool (United Kingdom); Hesseling, Markus; Subhedar, Nim [Liverpool Women' s Hospital, Department of Neonatology, Liverpool (United Kingdom); Roberts, Devender [Liverpool Women' s Hospital, Department of Fetal Medicine, Liverpool (United Kingdom)

    2005-08-01

    The cerebellar and pontocerebellar hypoplasias present a unique challenge when detected in the developing fetus. A diverse aetiology and prognosis make counselling of these families difficult. Advances in fetal imaging allow for more accurate diagnosis and counselling, but postnatal MRI is still required. A case is presented in which cerebellar hypoplasia was detected at 20 weeks gestation. Later fetal imaging provided further information, but a diagnosis of pontomedullary disconnection was not made until the postnatal MRI scan. The clinical findings and possible causes of such pontocerebellar abnormalities are discussed. (orig.)

  2. Sonographic Findings in Fetal Renal Vein Thrombosis.

    Science.gov (United States)

    Gerber, Rebecca E; Bromley, Bryann; Benson, Carol B; Frates, Mary C

    2015-08-01

    We present the sonographic findings of fetal renal vein thrombosis in a series of 6 patients. The mean gestational age at diagnosis was 31.2 weeks. Four cases were unilateral, and 2 were bilateral. The most common findings were renal enlargement and intrarenal vascular calcifications, followed by increased renal parenchymal echogenicity. Inferior vena cava thrombosis was found in 4 patients and common iliac vein thrombosis in 2. Fetal renal vein thrombosis is an uncommon diagnosis with characteristic sonographic findings. The presence of these findings should prompt Doppler interrogation of the renal vein and inferior vena cava to confirm the diagnosis.

  3. New treatment of early fetal chylothorax

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Sundberg, Karin; Nielsen, Henriette Svarre

    2007-01-01

    OBJECTIVE: To evaluate OK-432, a preparation of Streptococcus pyogenes, in the treatment of early fetal chylothorax. METHODS: A prospective study of all fetuses (n=7) with persistent early chylothorax (gestational ages 16-21 weeks) referred to the tertiary center of fetal medicine in Denmark in 2...... effusions, lung hypoplasia, or hydrops. CONCLUSION: Persistent early chylothorax is a condition with a high mortality rate and no established treatment option. Use of OK-432 is a promising therapy for selected fetuses with persistent chylothorax early in the second trimester....

  4. [Diagnosis of fetal malformations with ultrasound--state of development].

    Science.gov (United States)

    Fendel, M; Fendel, H

    1983-01-01

    Ultrasonography is of great importance for the prenatal diagnosis of fetal malformations and abnormalities. An early diagnosis in the second trimester is of great interest for an intrauterine or an extrauterine therapy planning (the choice of the time and mode of delivery). Defects of the neural tube including hydrocephalus, malformations of the extremities, the gastrointestinal tract, omphaloceles, the urogenital and cardiac system are described. Four cases of fetal malformations are presented: fetal myelomeningocele, hydrocephalus, bilateral hydronephrosis and lymphangioma with fetal ascites.

  5. Fetal Ascites and Second Trimester Maternal Hepatitis C Virus Infection

    Directory of Open Access Journals (Sweden)

    Pei-Ying Ling

    2006-09-01

    Conclusion: Second trimester perinatal HCV infection with possible CMV coinfection associated with fetal ascites is a rare event. Fetal therapy resulting in a successful outcome has not been reported. Prompt fetal therapy with paracentesis in this case led to the delivery of a healthy term liveborn baby with anti-HCV seropositivity.

  6. Agonist mediated fetal muscle-type nicotinic acetylcholine receptor desensitization

    Science.gov (United States)

    The exposure of a developing embryo or fetus to teratogenic alkaloids from plants has the potential to cause developmental defects in livestock due to the inhibition of fetal movement by alkaloids. The mechanism behind the inhibition of fetal movement is the desensitization of fetal muscle-type nico...

  7. Longitudinal study of computerized cardiotocography in early fetal growth restriction

    NARCIS (Netherlands)

    Wolf, H.; Arabin, B.; Lees, C. C.; Oepkes, D.; Prefumo, F.; Thilaganathan, B.; Todros, T.; Visser, G. H. A.; Bilardo, C. M.; Derks, J. B.; Diemert, A.; Duvekot, J. J.; Ferrazzi, E.; Frusca, T.; Hecher, K.; Marlow, N.; Martinelli, P.; Ostermayer, E.; Papageorghiou, A. T.; Scheepers, H. C. J.; Schlembach, D.; Schneider, K. T. M.; Valcamonico, A.; Van Wassenaer-Leemhuis, A.; Ganzevoort, W.

    Objectives: To explore whether, in early fetal growth restriction (FGR), the longitudinal pattern of fetal heart rate (FHR) short-term variation (STV) can be used to identify imminent fetal distress and whether abnormalities of FHR recordings are associated with 2-year infant outcome. Methods: The

  8. Oxidative Stress in Fetal Distress: Potential Prospects for Diagnosis

    Directory of Open Access Journals (Sweden)

    Saša Raicevic

    2010-01-01

    Full Text Available Our aim was to investigate the relation between fetal distress and oxidative stress. Fetal distress was associated with increased concentration of superoxide in the fetal blood and with significant increase of the level of H2O2 in both maternal and fetal blood. The activity of superoxide dismutase was increased roughly sixfold (p < 0.01 in the maternal [7330 ± 2240 U/g of hemoglobin in controls (C and 36811 ± 16862 U/g in fetal distress (FD] and fetal blood (C: 5930 ± 2641 U/g; FD: 41912 ± 17133 U/g. In contrast, fetal distress was related to a considerable decrease of catalase activity in both maternal (C: 26011 ± 8811 U/g; FD: 7212 ± 1270 U/g and fetal blood (C: 37194 ± 9191 U/g; FD: 6173 ± 1965 U/g. From this we concluded that in fetal distress, the maternal and fetal bloods are exposed to superoxide- and H2O2-mediated oxidative stress, which could be initiated by hypoxic conditions in the fetal blood and placenta. A tremendous increase/decrease of the activities of superoxide dismutase/catalase in the blood of women bearing a distressed fetus in comparison to healthy subjects implies that the assessment of superoxide dismutase/catalase activity could be of use for establishing a timely and accurate ante- or intrapartum diagnosis of fetal distress.

  9. Perspectives of fetal dystocia in cattle and buffalo

    Directory of Open Access Journals (Sweden)

    Govind Narayan Purohit

    2012-04-01

    Full Text Available We review the causes of fetal dystocia in cows and buffalo. Two fetal causes are distinct fetal oversize and fetal abnormalities. Fetal oversize is common in heifers, cows of beef cattle breeds, prolonged gestations, increased calf birth weight, male calves and perinatal fetal death with resultant emphysema. Fetal abnormalities include monsters, fetal diseases and fetal maldispositions, and it is difficult to deliver such fetuses because of their altered shape. Although monsters are rare in cattle, a large number of monstrosities have been reported in river buffalo; yet also here, overall incidence is low. Diseases of the fetus resulting in dystocia include hydrocephalus, ascites, anasarca and hydrothorax. The most common cause of dystocia in cattle seems to be fetal maldispositions, of which limb flexion and head deviation appear to be the most frequent. We provide a brief description of the management of dystocia from different causes in cattle and buffalo. A case analysis of 192 and 112 dystocia in cattle and buffalo, respectively, at our referral center revealed that dystocia is significantly higher (P<0.05 in first and second parity cows and buffalo, and that dystocia of fetal origin is common in cows (65.62% but less frequent (40.17% in buffalo. In buffalo, the single biggest cause of dystocia was uterine torsion (53.57%. Fetal survival was significantly (P<0.05 higher both in cows and buffalo when delivery was completed within 12 h of second stage of labor.

  10. 21 CFR 864.7455 - Fetal hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... hemoglobin present. The assay may be used to detect fetal red cells in the maternal circulation or to detect... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7455 Fetal...

  11. PulseSoar

    Energy Technology Data Exchange (ETDEWEB)

    Carter, P.; Peglow, S.

    1992-07-21

    This paper is an introduction to the PulseSoar concept. PulseSoar is a hypervelocity airplane that uses existing airport facilities and current technologies to fly at the very edge of space. It will be shown that PulseSoar can fly between any two points on the globe in less than two hours with fuel efficiency exceeding current state of the art commercial airliners. In addition, it will be shown that PulseSoar avoids environmental issues concerning the ozone layer and sonic booms because of its unique flight profile. All of this can be achieved with current technology. PulseSoar does not require the development of enabling technology. It is a concept which can be demonstrated today. The importance of this idea goes beyond the technical significance`s of PulseSoar in terms of feasibility and performance. PulseSoar could provide a crucial economic advantage to America`s largest export market: commercial aircraft. PulseSoar is a breakthrough concept for addressing the emerging markets of long range and high speed aircraft. Application of PulseSoar to commercial transport could provide the US Aerospace industry a substantial lead in offering high speed/long range aircraft to the world`s airlines. The rapid emergence of a US developed high speed aircraft could also be important to our competitiveness in the Pacific Rim and South American economies. A quick and inexpensive demonstration vehicle is proposed to bang the concept to reality within two years. This discussion will address all the major technical subjects encompassed by PulseSoar and identifies several near-term, and low risk, applications which may be further explored with the initial demonstration vehicle. What is PulseSoar? PulseSoar could enable high speed, high altitude and long range flight without many of the difficulties encountered by traditional hypersonic vehicles.

  12. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  13. Ultrashort Laser Pulse Phenomena

    CERN Document Server

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  14. Prenatal diagnosis of a placental infarction hematoma associated with fetal growth restriction, preeclampsia and fetal death: clinicopathological correlation.

    Science.gov (United States)

    Aurioles-Garibay, Alma; Hernandez-Andrade, Edgar; Romero, Roberto; Qureshi, Faisal; Ahn, Hyunyoung; Jacques, Suzanne M; Garcia, Maynor; Yeo, Lami; Hassan, Sonia S

    2014-01-01

    The lesion termed 'placental infarction hematoma' is associated with fetal death and adverse perinatal outcome. Such a lesion has been associated with a high risk of fetal death and abruption placentae. The fetal and placental hemodynamic changes associated with placental infarction hematoma have not been reported. This paper describes a case of early and severe growth restriction with preeclampsia, and progressive deterioration of the fetal and placental Doppler parameters in the presence of a placental infarction hematoma.

  15. MRI evaluation of fetal vitality and maturity; Avaliacao da vitalidade e maturidade fetal pela ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Rego, Salete J.F. [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil); Secaf, Eduardo [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina; Magalhaes, Alvaro Cebrian A. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina, Dept. de Radiologia

    1995-05-01

    Assessment of fetal vitality is an essential part of feto-maternal medicine. In clinical practice, this is carried out by investigation of the fetal growth pattern and biochemical or biophysical tests of fetal heath. MRI has the ability of characterizing different soft tissues and is the only technique that can display in the uterus the process of physiological myelinization and may well present a noninvasive method to determine lung maturity. MRI is more powerful technique allowing more detailed visualization of the fetal brain, better images can be obtained of areas such as posterior fossa. The major advantage of MRI over imaging modalities is the potential for biochemical and metabolic studies and it will make an important contribution to obstetric research. (author)., 10 refs., 7 figs p.

  16. Fetal subjects and maternal objects: reproductive technology and the new fetal/maternal relation.

    Science.gov (United States)

    Squier, S

    1996-10-01

    This essay examines three tendencies nurtured in the practices of reproductive technology - tendencies with profoundly disturbing implications for us as individuals and as social beings. They are: 1) the increasing subjectification of the fetus (that is, the increasing tendency to posit a fetal subject), 2) the increasing objectification of the gestating woman, leading to her representation as interchangeable object rather than unique subject, and 3) the increasing tendency to conceive of the fetus and the mother as social, medical, and legal antagonists. Considering the construction of fetus, mother, and the fetal/maternal relation in earlier (Western) historical periods, a contemporary work of literature, a government report, and the popular press, I argue that as the fetus is increasingly being understood as a subject, the mother is increasingly being reduced to an antagonist, an obstacle to fetal health, and an object. The essay concludes by offering some tentative conclusions about the general process of fetal subjectification in the United States and Europe.

  17. [Prenatal imaging of the fetal brain--indications and developmental implications of fetal MRI].

    Science.gov (United States)

    Ben Sira, Liat; Garel, Catherine; Leitner, Yael; Gross-Tsur, Varda

    2008-01-01

    Cerebral anomalies at birth account for approximately 9% of all isolated anomalies and are present in 15.9% of babies with multiple malformations and, thereby, warrant concern in antenatal diagnosis. Ultrasonography is the basic screening examination for the pregnant woman due to its efficiency, availability, low cost and real time capability. Many of the major anomalies can be diagnosed by ultrasound during the first trimester of pregnancy. However subtle abnormalities can be missed by ultrasonography or detected only in later stages of pregnancy. Fetal MRI has proved itself to be an effective adjuvant imaging tool and is indicated whenever there is a diagnostic query on ultrasound or a need to define a suspected brain anomaly. The information obtained from fetal MRI has significant implications for parental counseling regarding both the type of malformation as well as the neurological and developmental prognosis. Current indications for fetal MRI, focusing on various common fetal cerebral pathologies, will be addressed in this review.

  18. Fetal bladder wall regeneration with a collagen biomatrix and histological evaluation of bladder exstrophy in a fetal sheep model

    NARCIS (Netherlands)

    Roelofs, Luc A. J.; Eggink, Alex J.; de Kaa, Christina A. Hulsbergen-van; Wijnen, Rene M. H.; van Kuppevelt, Toin H.; van Moerkerk, Herman T. B.; Crevels, A. Jane; Hanssen, Alex; Lotgering, Fred K.; van den Berg, Paul P.; Feitz, Wout F. J.

    2008-01-01

    Objectives: To evaluate histological changes in an animal model for bladder exstrophy and fetal repair of the bladder defect with a molecular-defined dual-layer collagen biomatrix to induce fetal bladder wall regeneration. Methods: In 12 fetal lambs the abdominal wall and bladder were opened by a mi

  19. Fetal goiter and bilateral ovarian cysts

    DEFF Research Database (Denmark)

    Lassen, Pernille; Sundberg, Karin; Juul, Anders

    2008-01-01

    by each injection and followed by a gradual reduction of fetal goiter as well as the left ovarian cyst. The right cyst ruptured spontaneously. At 36 weeks + 4 days, the patient underwent elective caesarean section and gave birth to a female, weighing 2,880 g with 1- and 5-min Apgar scores of 10...

  20. Reduced fetal telomere length in gestational diabetes.

    Directory of Open Access Journals (Sweden)

    Jian Xu

    Full Text Available Gestational diabetes mellitus (GDM is an important complication of pregnancy that poses significant threats to women and their offspring. Telomere length shortens as cellular damage increases and is associated with metabolic diseases. Telomere length in fetal leucocytes was determined in 82 infants of women with GDM (N = 82 and 65 normal pregnant women (N = 65. Women with preeclampsia (N = 45 and gestational hypertension (N = 23 were also studied. In the GDM group, telomere length was significantly shorter than normal pregnancy (P = 0.028, but there were no significant differences in fetal telomere length between preeclampsia and normal pregnancy (P = 0.841 and between gestational hypertension and normal pregnancy (P = 0.561. Regression analysis revealed that fetal telomere length was significantly associated with intrauterine exposure to GDM (P = 0.027 after adjustment for maternal age, gestational age at delivery, birth weight and fetal gender. Shortened telomere length may increase the risk of metabolic diseases in adulthood of GDM offspring.

  1. Special Tests for Monitoring Fetal Health

    Science.gov (United States)

    ... growth problems, Rh sensitization , or high blood pressure • Decreased movement of the fetus • Pregnancy that goes past ... on how far along you are in your pregnancy, you may have another BPP within the next ... BPP performed? The fetal heart rate is monitored in the same way it is ...

  2. Ultrasound assessment of fetal cardiac function

    Science.gov (United States)

    Crispi, Fàtima; Valenzuela‐Alcaraz, Brenda; Cruz‐Lemini, Monica

    2015-01-01

    Abstract Introduction: Fetal heart evaluation with US is feasible and reproducible, although challenging due to the smallness of the heart, the high heart rate and limited access to the fetus. However, some cardiac parameters have already shown a strong correlation with outcomes and may soon be incorporated into clinical practice. Materials and Methods: Cardiac function assessment has proven utility in the differential diagnosis of cardiomyopathies or prediction of perinatal mortality in congenital heart disease. In addition, some cardiac parameters with high sensitivity such as MPI or annular peak velocities have shown promising results in monitoring and predicting outcome in intrauterine growth restriction or congenital diaphragmatic hernia. Conclusion: Cardiac function can be adequately evaluated in most fetuses when appropriate expertise, equipment and time are available. Fetal cardiac function assessment is a promising tool that may soon be incorporated into clinical practice to diagnose, monitor or predict outcome in some fetal conditions. Thus, more research is warranted to further define specific protocols for each fetal condition that may affect cardiac function. PMID:28191192

  3. MATERNO-FETAL IMMUNOTOLERANCE: AN EVOLUTIONARY VIEW

    Directory of Open Access Journals (Sweden)

    Luana Paulesu

    2013-12-01

    Full Text Available Since Medawar (1953, much attention has been given to the immunological paradox of the survival and growth of the semi-allogeneic fetus in the maternal uterus. Numerous studies, mainly on the human placenta, have established fundamental mechanisms of this phenomenon; however, many aspects are still unclear and the complex process has yet to be completely defined. One of the accepted principles is that the secretion and action of mediators, i.e. cytokines, at the materno-fetal interface have a central role. Focusing on the cytokine Interleukin-1 (IL-1 the review highlights the importance of a physiological approach based on evolutionary studies in animals using similar or different reproductive strategies. Data on IL-1 in viviparity and oviparity, two reproductive strategies in which female reproductive tissues have to deal with paternal-derived antigens on sperm, fertilized eggs, and embryo, will be presented and discussed in the light of materno-fetal immuntolerance. Ovuliparity, a reproductive modality in which the eggs are released from the female reproductive tract and fertilization and embryonic development take place in the external environment will also be extensively reported as a negative control in the studies on materno-fetal immunotolerance. The evidence shown reveals that non-mammalian vertebrates with different reproductive strategies represent a good model to understand biological mechanisms allowing fetal acceptance and growth in the maternal tissues.

  4. Imaging of the fetal central nervous system

    NARCIS (Netherlands)

    Pistorius, L.R.

    2008-01-01

    Introduction : Ultrasound and MR imaging of the fetal central nervous system (CNS) develop at an ever-increasing rate. Theoretically, the two modalities should be synergistic, but a literature review revealed the difficulties of determining the merit of either technique and revealed gaps in our know

  5. Anestesia para cirugía fetal

    National Research Council Canada - National Science Library

    Vasco Ramírez, Mauricio

    2012-01-01

    ...). El objetivo de este articulo es realizar una revision narrativa de la anestesia para la cirugia fetal. Metodologia Se realizo una busqueda no sistematica de publicaciones en bases de datos medicas que incluyeron MEDLINE, SciELO y EMBASE, utilizando los terminos > y restringida a los siguientes tipo...

  6. Fetal Alcohol Syndrome: A Behavioral Teratology.

    Science.gov (United States)

    Kavale, Kenneth A.; Karge, Belinda D.

    1986-01-01

    The review examines the literature on the behaviorally teratogenic aspects of Fetal Alcohol Syndrome, including: (1) prevalence of alcohol abuse among women, (2) acute and chronic effects of alcohol on the fetus, (3) genetic susceptibility, (4) neuropathology, (5) correlative conditions, and (6) animal studies. (Author/DB)

  7. Fetal programming of appetite and obesity.

    Science.gov (United States)

    Breier, B H; Vickers, M H; Ikenasio, B A; Chan, K Y; Wong, W P

    2001-12-20

    Obesity and related metabolic disorders are prevalent health issues in modern society and are commonly attributed to lifestyle and dietary factors. However, the mechanisms by which environmental factors modulate the physiological systems that control weight regulation and the aetiology of metabolic disorders, which manifest in adult life, may have their roots before birth. The 'fetal origins' or 'fetal programming' paradigm is based on the observation that environmental changes can reset the developmental path during intrauterine development leading to obesity and cardiovascular and metabolic disorders later in life. The pathogenesis is not based on genetic defects but on altered genetic expression as a consequence of an adaptation to environmental changes during fetal development. While many endocrine systems can be affected by fetal programming recent experimental studies suggest that leptin and insulin resistance are critical endocrine defects in the pathogenesis of programming-induced obesity and metabolic disorders. However, it remains to be determined whether postnatal obesity is a consequence of programming of appetite regulation and whether hyperphagia is the main underlying cause of the increased adiposity and the development of metabolic disorders.

  8. Neuroimaging and Fetal Alcohol Spectrum Disorders

    Science.gov (United States)

    Norman, Andria L.; Crocker, Nicole; Mattson, Sarah N.; Riley, Edward P.

    2009-01-01

    The detrimental effects of prenatal alcohol exposure on the developing brain include structural brain anomalies as well as cognitive and behavioral deficits. Initial neuroimaging studies of fetal alcohol spectrum disorders (FASD) using magnetic resonance imaging (MRI) confirmed previous autopsy reports of overall reduction in brain volume and…

  9. Fetal hydantoin syndrome: A case report

    National Research Council Canada - National Science Library

    Singh, A; Bhatia, HP; Mohan, A; Sharma, N

    2016-01-01

    ... it becomes mandatory to take anticonvulsants on regular basis during pregnancy. Fetal hydantoin syndrome (FHS) is a fetopathy likely to occur when a pregnant women takes hydantoin for epileptic seizures. Hanson and Smith in 1975 coined the term FHS. [4] Its classical features include growth and developmental delay, craniofacial anomalies, varying ...

  10. Jaundice during pregnancy: maternal and fetal outcome

    Directory of Open Access Journals (Sweden)

    Jayanthi Krishnamoorthy

    2016-08-01

    Conclusions: Jaundice in pregnancy has adverse fetomaternal outcome. Improvement in health awareness, education and regular antenatal checkups, early referrals result in early diagnosis and treatment of jaundice during pregnancy thus reducing maternal and fetal mortality and morbidity. [Int J Reprod Contracept Obstet Gynecol 2016; 5(8.000: 2541-2545

  11. Noninvasive fetal RhD genotyping

    DEFF Research Database (Denmark)

    Clausen, Frederik Banch; Damkjær, Merete Berthu; Dziegiel, Morten Hanefeld

    2014-01-01

    Immunization against RhD is the major cause of hemolytic disease of the fetus and newborn (HDFN), which causes fetal or neonatal death. The introduction of postnatal immune prophylaxis in the 1960s drastically reduced immunization incidents in pregnant, D-negative women. In several countries...

  12. Possible fetal determinants of male infertility

    DEFF Research Database (Denmark)

    Juul, Anders; Almstrup, Kristian; Andersson, Anna-Maria

    2014-01-01

    Although common reproductive problems, such as male infertility and testicular cancer, present in adult life, strong evidence exists that these reproductive disorders might have a fetal origin. The evidence is derived not only from large epidemiological studies that show birth-cohort effects...

  13. Fetal movements and placental lactogen levels for fetal-placental evaluation. A preliminary report.

    Science.gov (United States)

    Spellacy, W N; Cruz, A C; Gelman, S R; Buhi, W C

    1977-01-01

    Fetal movements were measured by 37 pregnant women during a 10-minute period while they were lying on their left side at various times during the day with the highest rates in the evening. Preliminary assessments of fetal movement and serum hPL levels in pregnant women suggest that the two tests might complement each other in providing more information about the status of the placenta and fetus.

  14. Fetal cardiac time intervals in healthy pregnancies - an observational study by fetal ECG (Monica Healthcare System).

    Science.gov (United States)

    Wacker-Gussmann, Annette; Plankl, Cordula; Sewald, Maria; Schneider, Karl-Theo Maria; Oberhoffer, Renate; Lobmaier, Silvia M

    2017-04-28

    Fetal electrocardiogram (fECG) can detect QRS signals in fetuses from as early as 17 weeks' gestation; however, the technique is limited by the minute size of the fetal signal relative to noise ratio. The aim of this study was to evaluate precise fetal cardiac time intervals (fCTIs) with the help of a newly developed fetal ECG device (Monica Healthcare System). In a prospective manner we included 15-18 healthy fetuses per gestational week from 32 weeks onwards. The small and wearable Monica AN24 monitoring system uses standard ECG electrodes placed on the maternal abdomen to monitor fECG, maternal ECG and uterine electromyogram (EMG). Fetal CTIs were estimated on 1000 averaged fetal heart beats. Detection was deemed successful if there was a global signal loss of less than 30% and an analysis loss of the Monica AN24 signal separation analysis of less than 50%. Fetal CTIs were determined visually by three independent measurements. A total of 149 fECGs were performed. After applying the requirements 117 fECGs remained for CTI analysis. While the onset and termination of P-wave and QRS-complex could be easily identified in most ECG patterns (97% for P-wave, PQ and PR interval and 100% for QRS-complex), the T-wave was detectable in only 41% of the datasets. The CTI results were comparable to other available methods such as fetal magnetocardiography (fMCG). Although limited and preclinical in its use, fECG (Monica Healthcare System) could be an additional useful tool to detect precise fCTIs from 32 weeks' gestational age onwards.

  15. Fetal Intracranial Hemorrhage (Fetal Stroke: Report of Four Antenatally Diagnosed Casesand Review of the Literature

    Directory of Open Access Journals (Sweden)

    Ying-Fen Huang

    2006-06-01

    Conclusion: This small series demonstrate that an antenatal diagnosis of fetal stroke with intraventricular hemorrhage Grades III and IV or with brain parenchymal involvement appears to be associated with poor neurologic outcome. Due to the significant neonatal neurologic impairment and potential medicolegal implications of antepartum fetal ICH, it follows that obstetricians and sonographers should be familiar with predisposing factors and typical diagnostic imaging findings of rare in utero ICH events.

  16. Development of quantitative Doppler indices for uteroplacental and fetal blood flow during the third trimester.

    Science.gov (United States)

    Joern, H; Funk, A; Goetz, M; Kuehlwein, H; Klein, A; Fendel, H

    1996-01-01

    The aim of our study was to describe the development of uteroplacental and fetal blood flow during the third trimester. Doppler examination was carried out on 393 uncomplicated pregnancies with uncomplicated term delivery. Using a pulsed color Doppler, we calculated the maximum systolic, mean and maximum end-diastolic velocity after correcting the angle of insonation. Patients under tocolysis or other medication influencing blood flow parameters were excluded from this cross-sectional study. Summarizing the results gained by Doppler ultrasound investigation of the uteroplacental and fetal blood vessels, we created quantiles as quantitative Doppler indices for the maximum systolic, mean (TAMX = time averaged maximum velocity) and maximum end-diastolic velocity. The following conclusions could be drawn: (1) resistance to the blood flow in the maternal portion of the placenta does not change during the third trimester; (2) resistance to the blood flow on the fetal side of the placenta decreases up to week 42 of gestation; (3) cerebral vascular resistance decreases constantly up to gestational week 42; and (4) vascular resistance to the blood flow of the kidney decreases only slightly during the third trimester. This study offers clinically important values for quantitative Doppler flow velocimetry for the first time. We hope that our findings improve the usefulness of Doppler ultrasound as a diagnostic tool in obstetrical management.

  17. The "Fetal Reserve Index": Re-Engineering the Interpretation and Responses to Fetal Heart Rate Patterns.

    Science.gov (United States)

    Eden, Robert D; Evans, Mark I; Evans, Shara M; Schifrin, Barry S

    2017-06-08

    Electronic fetal monitoring (EFM) correlates poorly with neonatal outcome. We present a new metric: the "Fetal Reserve Index" (FRI), formally incorporating EFM with maternal, obstetrical, fetal risk factors, and excessive uterine activity for assessment of risk for cerebral palsy (CP). We performed a retrospective, case-control series of 50 term CP cases with apparent intrapartum neurological injury and 200 controls. All were deemed neurologically normal on admission. We compared the FRI against ACOG Category (I-III) system and long-term outcome parameters against ACOG monograph (NEACP) requirements for labor-induced fetal neurological injury. Abnormal FRI's identified 100% of CP cases and did so hours before injury. ACOG Category III identified only 44% and much later. Retrospective ACOG monograph criteria were found in at most 30% of intrapartum-acquired CP patients; only 27% had umbilical or neonatal pH <7.0. In this initial, retrospective trial, an abnormal FRI identified all cases of labor-related neurological injury more reliably and earlier than Category III, which may allow fetal therapy by intrauterine resuscitation. The combination of traditional EFM with maternal, obstetrical, and fetal risk factors creating the FRI performed much better as a screening test than EFM alone. Our quantified screening system needs further evaluation in prospective trials. © 2017 S. Karger AG, Basel.

  18. Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.

    Science.gov (United States)

    Foo, Jong Yong A; Wilson, Stephen J; Dakin, Carolyn; Williams, Gordon; Harris, Margaret-Anne; Cooper, David

    2005-08-01

    Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in phase delay of the PPG signals. Masimo SET Rad-9 and Novametrix Oxypleth oximeters were investigated for their PPG phase characteristics on nine healthy adults. To facilitate comparison, PPG signals were acquired from fingers on the same hand in a random fashion. Results showed that mean PTT variations acquired from the Masimo oximeter (37.89 ms) were much greater than the Novametrix (5.66 ms). Documented evidence suggests that 1 ms variation in PTT is equivalent to 1 mmHg change in blood pressure. Moreover, the PTT trend derived from the Masimo oximeter can be mistaken as obstructive sleep apnoeas based on the known criteria. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG). Novametrix differed from ECG by 0.71+/-0.58% (pMasimo differed by 4.51+/-3.66% (p>0.05). Modern oximeters can be attractive for their improved SaO2 measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.

  19. Transcutaneous oximetry but not arterial toe blood pressure or ankle-brachial index is related to macular thickness in patients with chronic diabetic foot ulcers

    Directory of Open Access Journals (Sweden)

    Per Katzman

    2013-04-01

    Full Text Available Objectives: Diabetes related vascular complications of the lower extremity could be classified as micro- and macrovascular. Ankle-brachial index (ABI and toe blood pressure (TBP measurements evaluate macro-circulation, whereas transcutaneous oximetry (TcPO2 is considered to be a composite measure of vascular function, thereby also reflecting microcirculation. Microvascular disease in the eye involves abnormal capillary permeability and possibly thereby increased macular thickness. The aim of the present clinical study was to evaluate if microvascular disease in the eye was related to measures of foot ischemia in patients with diabetes mellitus. Methods: Twenty consecutive patients with diabetes and chronic full-thickness foot ulcers were included. Peripheral ischemia was diagnosed using TcPO2, TBP and ABI. Macular thickness was measured with optical coherence tomography technique. Results: Based on TcPO2, TBP and ABI measurements 14, 13 and 13 patients, respectively, were classified as ischemic. Patients with ischemic TcPO2 levels at the dorsum of the foot had significantly higher macular thicknesses. This was not the case in patients with ischemic TBP or ABI levels. Conclusion: TcPO2, unlike TBP and ABI, seems to be a clinically relevant measure of peripheral microvascular disease in patients with diabetes mellitus and may, if low, indicate an increased risk of macular edema. [J Exp Integr Med 2013; 3(2.000: 81-85

  20. Detection of fetal QRS-complexes by external methods.

    Science.gov (United States)

    Ahopelto, J; Hukkinen, K; Katila, T E; Laine, H; Kariniemi, V

    1975-01-01

    A new method is presented for detection of the QRS complexes and the fetal heart rate from the fetal magnetocardiogram and from the fetal electrocardiogram. In the method, the amplitude, the polarity and the shape of the QRS complex are tested. By using the described equipment it is possible to detect all consecutive heart beat intervals from a fetal electrocardiogram with less than 1% error in timing. When an external fetal electrocardiogram was used for testing, generally slightly over 10% of the QRS complexes were lost since they were simultaneous with the maternal complexes. In addition, complexes were also lost due to noise.

  1. Fetal eye movements on magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Ramona Woitek

    Full Text Available OBJECTIVES: Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. METHODS: Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]. Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981: Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. RESULTS: In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%. Significant differences between the age groups were found for Type I (p = 0.03, Type Ia (p = 0.031, and Type IV eye movements (p = 0.033. Consistently parallel bulbs were found in 27.3-45%. CONCLUSIONS: In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  2. Fetal eye movements on magnetic resonance imaging.

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  3. MRI of normal fetal brain development.

    Science.gov (United States)

    Prayer, Daniela; Kasprian, Gregor; Krampl, Elisabeth; Ulm, Barbara; Witzani, Linde; Prayer, Lucas; Brugger, Peter C

    2006-02-01

    Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a symmetrical or asymmetrical environment, leading to structural differences that may be demonstrated by DW-anisotropy; (3) changes in non-structural qualities, such as the onset of a membrane potential in premyelinating axons. The latter process also influences the appearance of a structure on DW sequences. Thus, we will review the in vivo MR appearance of different maturational states of the fetal brain and relate these maturational states to anatomical, histological, and in vitro MRI data. Then, the development of the cerebral cortex, white matter, temporal lobe, and cerebellum will be reviewed, and the MR appearance of transient structures of the fetal brain will be shown. Emphasis will be placed on the appearance of the different structures with the various sequences. In addition, the possible utility of dynamic fetal sequences in assessing spontaneous fetal movements is discussed.

  4. MRI of normal fetal brain development

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria)]. E-mail: Daniela.prayer@meduniwien.ac.at; Kasprian, Gregor [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria); Krampl, Elisabeth [Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna (Austria); Ulm, Barbara [Department of Prenatal Diagnosis, Medical University of Vienna, Vienna (Austria); Witzani, Linde [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria); Prayer, Lucas [Diagnosezentrum Urania, Vienna (Austria); Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna, Vienna (Austria)

    2006-02-15

    Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a symmetrical or asymmetrical environment, leading to structural differences that may be demonstrated by DW-anisotropy; (3) changes in non-structural qualities, such as the onset of a membrane potential in premyelinating axons. The latter process also influences the appearance of a structure on DW sequences. Thus, we will review the in vivo MR appearance of different maturational states of the fetal brain and relate these maturational states to anatomical, histological, and in vitro MRI data. Then, the development of the cerebral cortex, white matter, temporal lobe, and cerebellum will be reviewed, and the MR appearance of transient structures of the fetal brain will be shown. Emphasis will be placed on the appearance of the different structures with the various sequences. In addition, the possible utility of dynamic fetal sequences in assessing spontaneous fetal movements is discussed.

  5. Fetal Eye Movements on Magnetic Resonance Imaging

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  6. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  7. PULSE AMPLITUDE DISTRIBUTION RECORDER

    Science.gov (United States)

    Cowper, G.

    1958-08-12

    A device is described for automatica1ly recording pulse annplitude distribution received from a counter. The novelty of the device consists of the over-all arrangement of conventional circuit elements to provide an easy to read permanent record of the pulse amplitude distribution during a certain time period. In the device a pulse analyzer separates the pulses according to annplitude into several channels. A scaler in each channel counts the pulses and operates a pen marker positioned over a drivable recorder sheet. Since the scalers in each channel have the sanne capacity, the control circuitry permits counting of the incoming pulses until one scaler reaches capacity, whereupon the input is removed and an internal oscillator supplies the necessary pulses to fill up the other scalers. Movement of the chart sheet is initiated wben the first scaler reaches capacity to thereby give a series of marks at spacings proportional to the time required to fill the remaining scalers, and accessory equipment marks calibration points on the recorder sheet to facilitate direct reading of the number of external pulses supplied to each scaler.

  8. Fetal Growth and Timing of Parturition in Humans

    Science.gov (United States)

    Sundaram, Rajeshwari; Sun, Wenyu; Troendle, James

    2008-01-01

    Animal studies indicate that either the fetus or the intrauterine environment, both of which set the pattern for fetal growth, may affect the timing of parturition. The authors examined the association between fetal growth and timing of spontaneous onset of labor in humans among low-risk white US women with singleton pregnancies (1987–1991). They restricted the data to pregnancies which had a reliable date of the last menstrual period, normal fetal growth in the first half of pregnancy, and no history of or current pregnancy complications that might have impaired fetal growth (n = 3,360). Subjects received ultrasound examinations at 15–22 and 31–35 weeks’ gestation. Fetal growth was adjusted for parity, fetal sex, and maternal prepregnancy weight and height. Results showed that slower or faster fetal growth in the second half of pregnancy resulted in substantially lower or higher birth weight, respectively. However, fetal growth in the second half of pregnancy, even at extremes (2 standard deviations below or above the mean), did not have a meaningful impact on the timing of parturition; neither did fetal growth acceleration or deceleration in late pregnancy. Thus, in low-risk pregnancies where fetal growth is normal in early gestation, fetal growth in the second half of pregnancy does not affect the timing of normal parturition. PMID:18775925

  9. Fetal growth and timing of parturition in humans.

    Science.gov (United States)

    Zhang, Jun; Sundaram, Rajeshwari; Sun, Wenyu; Troendle, James

    2008-10-15

    Animal studies indicate that either the fetus or the intrauterine environment, both of which set the pattern for fetal growth, may affect the timing of parturition. The authors examined the association between fetal growth and timing of spontaneous onset of labor in humans among low-risk white US women with singleton pregnancies (1987-1991). They restricted the data to pregnancies which had a reliable date of the last menstrual period, normal fetal growth in the first half of pregnancy, and no history of or current pregnancy complications that might have impaired fetal growth (n = 3,360). Subjects received ultrasound examinations at 15-22 and 31-35 weeks' gestation. Fetal growth was adjusted for parity, fetal sex, and maternal prepregnancy weight and height. Results showed that slower or faster fetal growth in the second half of pregnancy resulted in substantially lower or higher birth weight, respectively. However, fetal growth in the second half of pregnancy, even at extremes (2 standard deviations below or above the mean), did not have a meaningful impact on the timing of parturition; neither did fetal growth acceleration or deceleration in late pregnancy. Thus, in low-risk pregnancies where fetal growth is normal in early gestation, fetal growth in the second half of pregnancy does not affect the timing of normal parturition.

  10. Identification of circulating fetal cell markers by microarray analysis

    DEFF Research Database (Denmark)

    Brinch, Marie; Hatt, Lotte; Singh, Ripudaman

    2012-01-01

    identified by XY fluorescence in situ hybridization and confirmed by reverse-color fluorescence in situ hybridization were shot off microscope slides by laser capture microdissection. The expression pattern of a subset of expressed genes was compared between fetal cells and maternal blood cells using stem......OBJECTIVE: Different fetal cell types have been found in the maternal blood during pregnancy in the past, but fetal cells are scarce, and the proportions of the different cell types are unclear. The objective of the present study was to identify specific fetal cell markers from fetal cells found...... in the maternal blood circulation at the end of the first trimester. METHOD: Twenty-three fetal cells were isolated from maternal blood by removing the red blood cells by lysis or combining this with removal of large proportions of maternal white blood cells by magnetic-activated cell sorting. Fetal cells...

  11. Recent advances in fetal near-infrared spectroscopy

    Science.gov (United States)

    D'Antona, Donato; Aldrich, Clive J.; O'Brien, Patrick; Lawrence, Sally; Delpy, David T.; Wyatt, John S.

    1997-01-01

    Fetal brain injury resulting from hypoxia and ischemia during labor remains an important cause of death and long- term disability. However, little is known about fetal brain oxygenation and hemodynamics. There are currently no satisfactory clinical techniques for fetal monitoring and there remains a need for a new method to assess brain oxygenation. Fetal near infrared spectroscopy (NIRS) is a new technique that allows noninvasive observation of changes in the cerebral concentrations of oxyhemoglobin and deoxyhemoglobin to be made during labor. A specially designed optical probe is inserted through the dilated cervix and placed against the fetal head. It is then possible to compare changes in NIRS data with other observations of fetal conditions, such as fetal heart rate and acid-base status.

  12. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    Florida State University is investigating the concept of pulsed electron beams for fly ash precipitation. This report describes the results and data on three of the subtasks of this project and preliminary work only on the remaining five subtasks. Described are the modification of precharger for pulsed and DC energization of anode; installation of the Q/A measurement system; and modification and installation of pulsed power supply to provide both pulsed and DC energization of the anode. The other tasks include: measurement of the removal efficiency for monodisperse simulated fly ash particles; measurement of particle charge; optimization of pulse energization schedule for maximum removal efficiency; practical assessment of results; and measurement of the removal efficiency for polydisperse test particles. 15 figs., 1 tab. (CK)

  13. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation.......Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  14. Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

    Science.gov (United States)

    Abdallah, Omar; Stork, Wilhelm; Muller-Glaser, Klaus

    2004-06-01

    The deficiencies of the currently used pulse oximeter are discussed in diverse literature. A hazardous pitfalls of this method is that the pulse oximeter will not detect carboxyhemoglobin (COHb) and methemoglobin (metHb) concentrations. This leads to incorrect measurement of oxygen saturation by carbon monoxide poisoning and methemoglobinemia. Also the total hemoglobin concentration will not be considered and can only be measured in-vitro up to now. A second pitfall of the standard pulse oximetry is that it will not be able to show a result by low perfusion of tissues. This case is available inter alia when the patient is under shock or has a low blood pressure. The new non-invasive system we designed measures the actual (fractional) oxygen saturation and hemoglobin concentration. It will enable us also to measure COHb and metHb. The measurement can be applied at better perfused body central parts. Four or more light emitting diodes (LEDs) or laser diodes (LDs) and five photodiodes (PDs) are used. The reflected light signal detected by photodiodes is processed using a modified Lambert-Beer law (I=I0×e-α.d ). According to this law, when a non scattering probe is irradiated with light having the incident intensity I0, the intensity of transmitted light I decays exponentially with the absorption coefficient a of that probe and its thickness d. Modifications of this law have been performed following the theoretical developed models in literature, Monte Carlo simulation and experimental measurement.

  15. The effects of pre-pregnancy obesity on fetal cardiac functions.

    Science.gov (United States)

    Ece, Ibrahim; Uner, Abdurrahman; Balli, Sevket; Kibar, Ayse Esin; Oflaz, Mehmet Burhan; Kurdoglu, Mertihan

    2014-06-01

    Obesity is a substantial public health problem with a rapidly increasing prevalence in numerous industrialized nations. The objective of this study was to evaluate the effects of maternal pre-pregnancy obesity on fetal cardiac functions. We studied 55 fetuses of obese mothers and 44 fetuses of healthy mothers at 26-38 weeks of gestation. Cardiac functions were evaluated by M-mode, pulsed-wave, and tissue Doppler echocardiography. The two groups were similar in terms of maternal age, gravidity, parity, gestational age, estimated birth weight, serum lipids, and systolic-diastolic blood pressure. Fetal heart rate, diameters of the aortic and pulmonary valve annulus, aortic and pulmonary peak systolic velocities, ventricular systolic function, and cardiothoracic ratio were similar in the two groups. Pulsed-wave Doppler-derived E/A ratios in the mitral and tricuspid valves were similar in the two groups. The deceleration time of early mitral inflow was prolonged in the fetuses of the obese mothers. In the interventricular septum, left ventricle posterior wall, and right ventricle free wall, the E a and A a were higher, and E a/A a ratios were significantly lower in the study group than in the control group. The E/E a ratio was higher in the obese group than in the control group. The isovolumic relaxation time and the right and left ventricle myocardial performance indices were higher in the fetuses of the obese mothers than in the fetuses of the healthy mothers. We believe that maternal obesity has an important influence on fetal cardiac diastolic functions.

  16. Online Detection of Fetal Acidemia during Labour by Testing Synchronization of EEG and Heart Rate: A Prospective Study in Fetal Sheep

    OpenAIRE

    2014-01-01

    Severe fetal acidemia during labour can result in life-lasting neurological deficits, but the timely detection of this condition is often not possible. This is because the positive predictive value (PPV) of fetal heart rate (FHR) monitoring, the mainstay of fetal health surveillance during labour, to detect concerning fetal acidemia is around 50%. In fetal sheep model of human labour, we reported that severe fetal acidemia (pH

  17. Cell-free fetal DNA and cell-free total DNA levels in spontaneous abortion with fetal chromosomal aneuploidy.

    Directory of Open Access Journals (Sweden)

    Ji Hyae Lim

    Full Text Available BACKGROUND: Cell-free fetal DNA and cell-free total DNA in maternal circulation have been proposed as potential markers for noninvasive monitoring of the placental condition during the pregnancy. However, the correlation of and change in cell-free fetal DNA and cell-free total DNA in spontaneous abortion (SA with fetal chromosomal aneuploidy have not yet been reported. Therefore, we investigated cell-free fetal DNA and cell-free total DNA levels in SA women with fetal chromosomal aneuploidy. METHODOLOGY/PRINCIPAL FINDINGS: A nested case-control study was conducted with maternal plasma collected from 268 women in their first trimester of pregnancy. Subjects included 41 SA with normal fetal karyotype, 26 SA with fetal chromosomal aneuploidy, and 201 normal controls. The unmethylated PDE9A gene was used to measure the maternal plasma levels of cell-free fetal DNA. The GAPDH gene was used to measure the maternal plasma levels of cell-free total DNA. The diagnostic accuracy was measured using receiver-operating characteristic (ROC curves. Levels of cell-free fetal DNA and cell-free total DNA were significantly higher in both SA women with normal fetal karyotype and SA women with fetal chromosomal aneuploidy in comparison with the normal controls (P<0.001 in both. The correlation between cell-free fetal DNA and cell-free total DNA levels was stronger in the normal controls (r = 0.843, P<0.001 than in SA women with normal karyotype (r = 0.465, P = 0.002 and SA women with fetal chromosomal aneuploidy (r = 0.412, P = 0.037. The area under the ROC curve for cell-free fetal DNA and cell-free total DNA was 0.898 (95% CI, 0.852-0.945 and 0.939 (95% CI, 0.903-0.975, respectively. CONCLUSIONS: Significantly high levels of cell-free fetal DNA and cell-free total DNA were found in SA women with fetal chromosomal aneuploidy. Our findings suggest that cell-free fetal DNA and cell-free total DNA may be useful biomarkers for the prediction of SA

  18. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  19. Efficient Pulsed Quadrupole

    CERN Document Server

    Petzenhauser, I.; Spiller, P.; Tenholt, C.

    2016-01-01

    In order to raise the focusing gradient in case of bunched beam lines, a pulsed quadrupole was designed. The transfer channels between synchrotrons as well as the final focusing for the target line are possible applications. The quadrupole is running in a pulsed mode, which means an immense saving of energy by avoiding standby operation. Still the high gradients demand high currents. Hence a circuit had to be developed which is able to recover a significant amount of the pulsing energy for following shots. The basic design of the electrical circuit of the quadrupole is introduced. Furthermore more energy efficient circuits are presented and the limits of adaptability are considered.

  20. Pulse joining cartridges

    Energy Technology Data Exchange (ETDEWEB)

    Golovashchenko, Sergey Fedorovich; Bonnen, John Joseph Francis

    2016-08-23

    A pulsed joining tool includes a tool body that defines a cavity that receives an inner tubular member and an outer tubular member and a pulse joining cartridge. The tubular members are nested together with the cartridge being disposed around the outer tubular member. The cartridge includes a conductor, such as a wire or foil, that extends around the outer tubular member and is insulated to separate a supply segment from a return segment. A source of stored electrical energy is discharged through the conductor to join the tubular members with an electromagnetic force pulse.

  1. DogPulse

    DEFF Research Database (Denmark)

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo;

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  2. Hormonal and metabolic responses of fetal lamb during cardiopulmonary bypass

    Institute of Scientific and Technical Information of China (English)

    苏肇伉; 周成斌; 张海波; 祝忠群

    2003-01-01

    Objective To study the hormonal and metabolic responses of fetal lamb during cardiopulmonary bypass.Methods Six pregnant ewes underwent fetal cardiopulmonary bypasses with artificial oxygenators and roller pumps for 30 minutes, which maintained the blood gas value at the fetal physiological level. The fetal blood pressure, heart rate, pH value and blood lactate levels were monitored. The levels of catecholamine, cortisol and insulin were measured pre-bypass and then again 30 minutes later. The blood glucose and free fatty acid levels were monitored continuously during the bypass. Fetal hepatic PAS staining was also carried out.Results There were no changes before and during the bypass in fetal blood pressure, heart rate and blood gas. However, pH values decreased and blood lactate levels increased (P<0.05). The fetal catecholamine and cortisol levels increased significantly (P<0.01), while the levels of insulin did not change. The blood glucose and free fatty acid levels increased at the beginning of the bypass (P<0.01), and then gradually slowed down during the bypass. The fetal hepatic PAS staining showed that hepatic glycogen was consumed in large amounts. After 30 minutes of bypass, the fetal lamb would not survive more than 1 hour.Conclusion The fetal lamb has a strong negative reaction to cardiopulmonary bypass.

  3. Impaired fetal adrenal function in intrahepatic cholestasis of pregnancy

    Science.gov (United States)

    Wang, Chunfang; Chen, Xiaojun; Zhou, Shu-Feng; Li, Xiaotian

    2011-01-01

    Summary Background Intrahepatic cholestasis of pregnancy (ICP) is a pregnancy-associated liver disease of unknown etiology. The aim of this study was to investigate the change in maternal and fetal adrenal function in clinical and experimental ICP. Material/Methods The maternal and fetal serum levels of cortisol and dehydroepiandrosterone sulfate (DHEAS) were determined in 14 women with ICP and in pregnant rats with estrogen-induced intrahepatic cholestasis. Results In women with ICP, the fetal serum cortisol and DHEAS levels were significantly higher than those in women with normal pregnancy, after correcting the impact of gestational age at delivery. The relationship between fetal cortisol and maternal cholic acid levels was bidirectional; the fetal cortisol tended to increase in mild ICP, while it decreased in severe ICP. In pregnant rats with estrogen-induced cholestasis, the fetal cortisol level was significantly lower in the group with oxytocin injection, compared with the group without oxytocin injection (191.92±18.86 vs. 272.71±31.83 ng/ml, P<0.05). In contrast, the fetal cortisol concentration was increased after oxytocin injection in normal control rats. Conclusions The data indicate that fetal stress-responsive system is stimulated in mild ICP, but it is suppressed in severe ICP, which might contribute to the occurrence of unpredictable sudden fetal death. Further studies are warranted to explore the role of impaired fetal adrenal function in the pathogenesis of ICP and the clinical implications. PMID:21525808

  4. Fetal Axillary Cystic Hygroma; a case report and review

    Directory of Open Access Journals (Sweden)

    Ecmel Isık

    2011-10-01

    Full Text Available The Cystic Hygroma (CH is a lymphatic malformation occurring different parts of fetal body, typically in the region of the fetal neck and axillary, abdominal wall, mediastinal, inguinal and retroperitoneal areas. CH has been associated with fetal aneuploidy, hydrops fetalis, structural malformations and intrauterine fetal death. A 24-years-old gravida 1, para 1 was admitted to our hospital at 28 weeks of gestation. Ultrasonographic examination determined 28 weeks of gestation, singleton, alive fetus who had a mass derived from the right axillary region which was extending to the anterior and posterior thoracic wall with fluid-filled cavities about 12 cm in size. There was no evidence of intrathorasic or intraabdominal extension of mass. Cordocentesis was performed and karyotype examination was normal 46 XY. The fetal demise was found after the first visit. The patient was delivered vaginally after labor induction with oxytocin infusion. The fetal autopsy confirmed the diagnosis of CH. The fetal CH carries high risk of aneuploidy and fetal malformations. Patients that have been diagnosed with CH in antenatal follow-ups should be assessed in terms of other anomalies. Fetal karyotyping should be done and the patient should be monitored for fetal hydrops. The birth should be planned in a multidisciplinary hospital and as neonatal resuscitation could be needed, pediatricians should be consulted.

  5. Metabolomics Application in Maternal-Fetal Medicine

    Directory of Open Access Journals (Sweden)

    Vassilios Fanos

    2013-01-01

    Full Text Available Metabolomics in maternal-fetal medicine is still an “embryonic” science. However, there is already an increasing interest in metabolome of normal and complicated pregnancies, and neonatal outcomes. Tissues used for metabolomics interrogations of pregnant women, fetuses and newborns are amniotic fluid, blood, plasma, cord blood, placenta, urine, and vaginal secretions. All published papers highlight the strong correlation between biomarkers found in these tissues and fetal malformations, preterm delivery, premature rupture of membranes, gestational diabetes mellitus, preeclampsia, neonatal asphyxia, and hypoxic-ischemic encephalopathy. The aim of this review is to summarize and comment on original data available in relevant published works in order to emphasize the clinical potential of metabolomics in obstetrics in the immediate future.

  6. Infertility, infertility treatment, and fetal growth restriction

    DEFF Research Database (Denmark)

    Zhu, Jin Liang; Obel, Carsten; Hammer Bech, Bodil

    2007-01-01

    OBJECTIVE: To examine the association between infertility, with or without treatment, and fetal growth, as well as perinatal and infant mortality. METHODS: From the Danish National Birth Cohort (1997-2003), we identified 51,041 singletons born of fertile couples (time to pregnancy 12 months or less......), 5,787 born of infertile couples conceiving naturally (time to pregnancy more than 12 months), and 4,317 born after treatment. We defined small for gestational age (SGA) as the lowest 5% of birth weight by sex and gestational age. RESULTS: Crude estimates suggested an increased risk of perinatal...... effect on fetal growth. A small-to-moderate increased risk of perinatal mortality in infertile couples cannot be ruled out due to the small number of cases. LEVEL OF EVIDENCE: II. Udgivelsesdato: 2007-Dec...

  7. Fetal microchimerism in breast and colon cancer

    DEFF Research Database (Denmark)

    Kamper-Jørgensen, M; Biggar, R J; Stamper, Casey L

    2011-01-01

    . DNA from repository buffy coat specimens was tested for male FMc with quantitative PCR targeting the DYS14gene on the Y chromosome. For this analysis, 89 women who developed breast cancer and 67 women who developed colon cancer were evaluable for FMc. Results were compared to 272 women who remained......1574 Background: Cells acquired by a woman from her baby that durably persist in her blood and tissues is known as fetal microchimerism (FMc). In women with breast cancer, frequency and quantity of FMc in blood and breast tissue is reduced compared to healthy women. Whether the absence of fetal...... microchimerism predicts risk for developing breast cancer is unknown. FMc was evaluated in buffy coat cells from presumed healthy women who later developed breast cancer or colon cancer, a cancer in which prior pregnancy appears protective but has different associations with endocrine risk factors. METHODS...

  8. Metabolomics application in maternal-fetal medicine.

    Science.gov (United States)

    Fanos, Vassilios; Atzori, Luigi; Makarenko, Karina; Melis, Gian Benedetto; Ferrazzi, Enrico

    2013-01-01

    Metabolomics in maternal-fetal medicine is still an "embryonic" science. However, there is already an increasing interest in metabolome of normal and complicated pregnancies, and neonatal outcomes. Tissues used for metabolomics interrogations of pregnant women, fetuses and newborns are amniotic fluid, blood, plasma, cord blood, placenta, urine, and vaginal secretions. All published papers highlight the strong correlation between biomarkers found in these tissues and fetal malformations, preterm delivery, premature rupture of membranes, gestational diabetes mellitus, preeclampsia, neonatal asphyxia, and hypoxic-ischemic encephalopathy. The aim of this review is to summarize and comment on original data available in relevant published works in order to emphasize the clinical potential of metabolomics in obstetrics in the immediate future.

  9. Fetal chromosome analysis: screening for chromosome disease?

    DEFF Research Database (Denmark)

    Philip, J; Tabor, Ann; Bang, J

    1983-01-01

    The aim of the study was to investigate the rationale of the current indications for fetal chromosome analysis. 5372 women had 5423 amniocentesis performed, this group constituting a consecutive sample at the chromosome laboratory, Rigshospitalet, Copenhagen from March 1973 to September 1980 (Group...... to women having amniocentesis, although considered not to have any increased risk of fetal chromosome abnormality (1390 pregnancies, group B). They were also compared with 750 consecutive pregnancies in women 25-34 years of age, in whom all heritable diseases were excluded (group C). The risk of unbalanced...... with women without elevated risk. Spontaneous abortion rate and prematurity rate did not differ from rates expected without amniocentesis. It is concluded that current indications may be characterized as a mixture of evident high risk factors and factors with only a minor influence on risk. Indications...

  10. Octreotide therapy and restricted fetal growth

    DEFF Research Database (Denmark)

    Geilswijk, Marianne; Andersen, Lise Lotte Torvin; Frost, Morten

    2017-01-01

    growth velocity was normal. We conclude that octreotide treatment during pregnancy may pose a risk of fetal growth restriction and warrants careful consideration. In some cases of familial hyperinsulinemic hypoglycemia, blood glucose levels can be successfully managed through diet only, also during......SUMMARY: Hypoglycemia during pregnancy can have serious health implications for both mother and fetus. Although not generally recommended in pregnancy, synthetic somatostatin analogues are used for the management of blood glucose levels in expectant hyperinsulinemic mothers. Recent reports suggest...... that octreotide treatment in pregnancy, as well as hypoglycemia in itself, may pose a risk of fetal growth restriction. During pregnancy, management of blood glucose levels in familial hyperinsulinemic hypoglycemia thus forms a medical dilemma. We report on pregnancy outcomes in a woman with symptomatic familial...

  11. Value of fetal skeletal radiographs in the diagnosis of fetal death

    Energy Technology Data Exchange (ETDEWEB)

    Bourliere-Najean, B.; Russel, A.S.; Petit, P.; Devred, P. [Department of Pediatric Radiology, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France); Panuel, M. [Department of Radiology, Hopital Nord, chemin Bourrelys, 13915 Marseille cedex 20 (France); Piercecchi-Marti, M.D.; Fredouille, C. [Department of Pathology, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France); Sigaudy, S.; Philip, N. [Department of Genetics, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France)

    2003-05-01

    The aim of this study was to assess the value of fetal skeletal radiographs in determining the etiology of fetal death. A total of 1193 post-mortem fetal skeletal radiographs were analysed. Fetuses were classified into one of three groups (group I: abnormality diagnosed during pregnancy; group II: maternal pathology; group III: spontaneous abortion of pregnancy, IIIa before 26 weeks of gestation (WG), IIIb after 26 weeks of gestation). Face, supine and lateral skeletal views were performed. Skeletal abnormalities were detected in 33.9% of the fetuses, including 22.7% with minor abnormalities (abnormal rib number, no nasal bone ossification, amesophalangia or P2 hypoplasia of the fifth digit) and 14.5% with major abnormalities (other skeletal abnormalities). Among the fetuses with major abnormalities, 98.8% came from group I, 2.9% came from group II, 2.3% came from group IIIa and none came from group IIIb. Fetal skeletal radiographs are not useful in fetuses arising from spontaneous abortion of pregnancy without abnormality on ultrasound screening, abnormality clinical examination or in fetuses with prenatal diagnosis of chromosomal abnormality. This practice is valuable only if there is a multidisciplinary team, with all the participants (pathologists, radiologists, geneticists) knowledgeable about fetal pathology. In the absence of this multidisciplinary approach, it is easier to X-ray all fetuses to avoid misdiagnosis and the important consequences for genetic counselling. (orig.)

  12. Placental adaptations to the maternal-fetal environment: implications for fetal growth and developmental programming.

    Science.gov (United States)

    Sandovici, Ionel; Hoelle, Katharina; Angiolini, Emily; Constância, Miguel

    2012-07-01

    The placenta is a transient organ found in eutherian mammals that evolved primarily to provide nutrients for the developing fetus. The placenta exchanges a wide array of nutrients, endocrine signals, cytokines and growth factors with the mother and the fetus, thereby regulating intrauterine development. Recent studies show that the placenta is not just a passive organ mediating maternal-fetal exchange. It can adapt its capacity to supply nutrients in response to intrinsic and extrinsic variations in the maternal-fetal environment. These dynamic adaptations are thought to occur to maximize fetal growth and viability at birth in the prevailing conditions in utero. However, some of these adaptations may also affect the development of individual fetal tissues, with patho-physiological consequences long after birth. Here, this review summarizes current knowledge on the causes, possible mechanisms and consequences of placental adaptive responses, with a focus on the regulation of transporter-mediated processes for nutrients. This review also highlights the emerging roles that imprinted genes and epigenetic mechanisms of gene regulation may play in placental adaptations to the maternal-fetal environment. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Can postmortem fetal MR imaging replace autopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jeong Yeon; Song, Mi Jin [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Kim, Seoung Hyup [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-02-01

    The purposes of this study were to compare postmortem fetal MRI findings with autopsy findings and to assess whether postmortem MRI can replace autopsy. The study group consisted of 13 stillborn fetuses, seven that died immediately after birth, and five terminated because of anomalies seen on prenatal sonograms. A total 17 were male, and eight were female, and their gestational ages were from 20 to 41 (average;28.2) weeks. Spin-echo T1-and T2-weighted axial, sagittal, and coronal MR images were obtained, and autopsy findings were divided into major and minor. A major finding was defined as an anomaly or syndrome which caused fetal death or termination of the pregnancy: minor findings were classified, on the basis of gross inspection, as internal or external. MR images were retrospectively analyzed by two radiologists unaware of the autopsy findings, and by comparison with these, the postmortem MRI detection rates for major and minor findings was then determined. In seven of 25 fetuses, MR imaging revealed major findings, a dietction rate of 100%. There were two cases of anencephaly, two of trisomy-18, and one each of hydrops fetalis with large cystic hygroma, diaphragmatic hernia, and Dandy-Walker malformation. Twenty-three of 60 minor findings (38.3%) were detected by MRI. The detection rates for external and internal findings were 29.6%(8/27) and 45.5%(15/33), respectively. Although a limitation of our study is the low detection rate for minor findings, postmortem fetal MRI may help diagnose the major cause of fetal death.

  14. Induction of fetal demise before abortion.

    Science.gov (United States)

    Diedrich, Justin; Drey, Eleanor

    2010-06-01

    For decades, the induction of fetal demise has been used before both surgical and medical second-trimester abortion. Intracardiac potassium chloride and intrafetal or intra-amniotic digoxin injections are the pharmacologic agents used most often to induce fetal demise. In the last several years, induction of fetal demise has become more common before second-trimester abortion. The only randomized, placebo-controlled trial of induced fetal demise before surgical abortion used a 1 mg injection of intra-amniotic digoxin before surgical abortion at 20-23 weeks' gestation and found no difference in procedure duration, difficulty, estimated blood loss, pain scores or complications between groups. Inducing demise before induction terminations at near viable gestational ages to avoid signs of life at delivery is practiced widely. The role of inducing demise before dilation and evacuation (D&E) remains unclear, except for legal considerations in the United States when an intact delivery is intended. There is a discrepancy between the one published randomized trial that used 1 mg intra-amniotic digoxin that showed no improvement in D&E outcomes and observational studies using different routes, doses and pre-abortion intervals that have made claims for its use. Additional randomized trials might provide clearer evidence upon which to make further recommendations about any role of inducing demise before surgical abortion. At the current time, the Society of Family Planning recommends that pharmacokinetic studies followed by randomized controlled trials be conducted to assess the safety and efficacy of feticidal agents to improve abortion safety.

  15. Fetal hydantoin syndrome: A case report

    Directory of Open Access Journals (Sweden)

    A Singh

    2016-01-01

    Full Text Available Fetal hydantoin syndrome (FHS is a spectrum of defects caused to the developing fetus by exposure to the teratogenic effects of antiepileptic drug (AED phenytoin during pregnancy. Its clinical manifestations include limb abnormalities, ocular defects, central nervous system anomalies, intrauterine growth restriction, and hand and phalangeal anomalies. This case report presents an 8-year-old child born to an epileptic mother with a history of AED therapy, with features suggestive of FHS.

  16. Maturation of Fetal Responses to Music

    Science.gov (United States)

    Kisilevsky, B. S.; Hains, S. M. J.; Jacquet, A.-Y.; Granier-Deferre, C.; Lecanuet, J. P.

    2004-01-01

    Maturation of fetal response to music was characterized over the last trimester of pregnancy using a 5-minute piano recording of Brahms' Lullaby, played at an average of 95, 100, 105 or 110 dB (A). Within 30 seconds of the onset of the music, the youngest fetuses (28-32 weeks GA) showed a heart rate increase limited to the two highest dB levels;…

  17. Fetal MR imaging diagnosis of pulmonary agenesis.

    Science.gov (United States)

    Kuwashima, Shigeko; Kaji, Yasushi

    2010-01-01

    A woman was referred to our institution with an ultrasound (US) suggestive of right-sided heart in fetus at 34 weeks' gestation. Magnetic resonance (MR) imaging revealed right-sided heart, small right hemithorax, and completely absent right main bronchus and right pulmonary artery. From our experience with this case, we point out 5 important MR imaging findings needed for prenatal diagnosis of pulmonary agenesis. Fetal MR imaging also provided information about anomalies of other organs.

  18. Normal renal development investigated with fetal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Witzani, Linde [Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)]. E-mail: linde.witzani@aon.at; Brugger, Peter Christian [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, A-1090 Vienna (Austria); Hoermann, Marcus [Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kasprian, Gregor [Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Csapone-Balassy, Csilla [Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2006-02-15

    Objective: To evaluate age-dependent changes in fetal kidney measurements with MRI. Patients and methods: Fetal MRI examinations were used to study the kidney length (218 fetuses), signal intensities of renal tissue, renal pelvis, and liver tissue on T2-weighted images (223 fetuses), and the whole-kidney apparent diffusion coefficient (107 fetuses). A 1.5 T superconducting unit with a phased array coil was used in patients from 16 to 39 weeks' gestation. The imaging protocol included T2-weighted single-shot fast spin-echo, T2-weighted balanced angiography and diffusion-weighted sequences. Slice thickness ranged from 3 to 5 mm. Results: Fetal kidney length as a function of gestational age was expressed by the linear regression: kidney length (mm) = 0.190 x gestational age (d) - 8.034 (R {sup 2} 0.883, p < 0.001). Paired t-test analysis showed a highly statistically significant difference between the ratio of renal tissue signal intensity to renal pelvis signal intensity and the ratio of liver signal intensity to renal pelvis signal intensity on T2-weighted images (t = -50.963, d.f. = 162, p < 0.001), with renal tissue hyperintense to liver tissue. The apparent diffusion coefficient in relation to gestational age was described by the equation: ADC ({mu}m{sup 2}/s) = 0.0302 x square (gestational age (d)) - 14.202 x gestational age (d) + 2728.6 (R {sup 2} = 0.225, p < 0.001). Conclusion: The length, signal intensity on T2-weighted images, and apparent diffusion coefficient of the fetal kidney change significantly with gestational age. The presented data may help in the prenatal diagnosis of renal anomalies.

  19. Normal renal development investigated with fetal MRI.

    Science.gov (United States)

    Witzani, Linde; Brugger, Peter Christian; Hörmann, Marcus; Kasprian, Gregor; Csapone-Balassy, Csilla; Prayer, Daniela

    2006-02-01

    To evaluate age-dependent changes in fetal kidney measurements with MRI. Fetal MRI examinations were used to study the kidney length (218 fetuses), signal intensities of renal tissue, renal pelvis, and liver tissue on T2-weighted images (223 fetuses), and the whole-kidney apparent diffusion coefficient (107 fetuses). A 1.5 T superconducting unit with a phased array coil was used in patients from 16 to 39 weeks' gestation. The imaging protocol included T2-weighted single-shot fast spin-echo, T2-weighted balanced angiography and diffusion-weighted sequences. Slice thickness ranged from 3 to 5mm. Fetal kidney length as a function of gestational age was expressed by the linear regression: kidney length (mm)=0.190 x gestational age (d) -8.034 (R(2) = 0.883, p < 0.001). Paired t-test analysis showed a highly statistically significant difference between the ratio of renal tissue signal intensity to renal pelvis signal intensity and the ratio of liver signal intensity to renal pelvis signal intensity on T2-weighted images (t = -50.963, d.f. = 162, p < 0.001), with renal tissue hyperintense to liver tissue. The apparent diffusion coefficient in relation to gestational age was described by the equation: ADC (microm(2)/s) = 0.0302 x square (gestational age (d)) -14.202 x gestational age (d) +2,728.6 (R(2) = 0.225, p < 0.001). The length, signal intensity on T2-weighted images, and apparent diffusion coefficient of the fetal kidney change significantly with gestational age. The presented data may help in the prenatal diagnosis of renal anomalies.

  20. Umbilical Cord Segmental Hemorrhage and Fetal Distress

    Science.gov (United States)

    Larciprete, Giovanni; Romanini, Maria Elisabetta; Arduini, Domenico; Cirese, Elio; Slowikowska-Hilczer, Jolanta; Kula, Krzysztof

    2006-01-01

    We describe an unexplained case of umbilical cord segmental hemorrhage linked with meconium-stained amniotic fluid. A severely asphyxiated infant was delivered at term by Caesarean section. There were poor prognostic signs on fetal cardiotocography with rupture of membranes with meconium-stained amniotic fluid. The pathophysiologic mechanism in this case is still unknown, even if we argued a possible role of the umbilical cord shortness. PMID:23674981