WorldWideScience

Sample records for femoral resection arthroplasty

  1. [PERSONALIZED DISTAL FEMORAL VALGUS RESECTION ANGLE IN PRIMARY TOTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Wang, Xilong; Shang, Xifu; Ll, Guoyuan; He, Rui; Zheng, Jie

    2015-01-01

    To investigate the feasibility and effectiveness of a personalized distal femoral valgus resection angle for improving postoperative coronal alignment of lower limb in total knee arthroplasty (TKA). A retrospective analysis was made on the clinical data of 50 patients who received primary TKA between January 2013 and February 2013. There were 11 male and 39 female patients with degenerative knee osteoarthritis. The patients were divided into 2 groups. In test group (n=25), the resection angle was adjusted to the femoral mechanical anatomical angle (FMA); in control group (n=25), a fixed distal valgus resection angle of 5° was used. There was no significant difference in gender, age, body mass index, disease duration, sides, grade, preoperative FMA, mechanical femorotibial angle (MFT), and preoperative Knee Society Score (KSS) between 2 groups (P > 0.05). Whole long X-ray film was taken to measure FMA and MFT at 3 days after operation, postoperative KSS was used to evaluate the knee function after 6 and 15 months. MFT was (-0.20 ± 1.87)° in test group and was (1.71 ± 3.67)° in control group, showing significant difference between 2 groups (t = 2.32, P = 0.02). The ideal MFT angle (0 ± 3)° was achieved in 22 patients (88%) of test group and in 16 patients (64%) of control group, showing significant difference between 2 groups (χ2 = 2.32, P = 0.02). Primary healing of incision was obtained in all patients of 2 groups. No deep venous thrombosis occurred. The patients of 2 groups were followed up 15 months after operation. There was significant difference in KSS between test and control groups at 6 months (88.23 ± 2.57 vs. 82.92 ± 2.59) (t = 7.26, P = 0.00) and at 15 months (90.76 ± 2.77 vs. 88.65 ± 1.77) (t = 3.20, P = 0.02). No sign of prosthesis loosening was observed by X-ray examination. Compared with using of a fixed distal femoral resection angle, an individual FMA can significantly improve the postoperative MFT and promote early recovery of the knee

  2. Finding the unexpected: pathological examination of surgically resected femoral heads

    Energy Technology Data Exchange (ETDEWEB)

    Fornasier, V.L. [St. Michael' s Hospital, University of Toronto, Department of Laboratory Medicine and Pathobiology, Toronto, Ontario (Canada); Battaglia, D.M. [St. Michael' s Hospital, University of Toronto, Department of Laboratory Medicine and Pathobiology, Toronto, Ontario (Canada); St. Michael' s Hospital, University of Toronto, Division of Pathology, Toronto, Ontario (Canada)

    2005-06-01

    To study the clinically diagnosed disease process but also identify additional, clinically undetected pathologies in femoral heads resected for replacement arthroplasty. A retrospective review was carried out of the pathological findings in 460 surgically resected femoral heads. Serial sections were submitted to low-energy fine-detail radiography, then decalcified sections stained by the WHO method were examined. The preoperative clinical and imaging diagnoses were compared with the pathological findings and special interest was placed on assessing the clinical significance of any unexpected, clinically undetected findings. The most common findings included the presence of bone islands (solitary osteomas) and areas of avascular necrosis in addition to the primary joint disease for which the patient underwent surgery. The preoperative symptomatology did not distinguish between the known primary disease and the additional pathological findings. Some of the clinically unidentified lesions were of a size that fell below the ability of current clinical investigations to detect. However, the finding of lesions by tissue fine-detail radiography indicates that current, more sensitive clinical imaging techniques may identify them. Careful examination of surgically resected femoral heads is important to ensure that all pathologies are identified and assessed for clinical relevance. (orig.)

  3. Finding the unexpected: pathological examination of surgically resected femoral heads

    International Nuclear Information System (INIS)

    Fornasier, V.L.; Battaglia, D.M.

    2005-01-01

    To study the clinically diagnosed disease process but also identify additional, clinically undetected pathologies in femoral heads resected for replacement arthroplasty. A retrospective review was carried out of the pathological findings in 460 surgically resected femoral heads. Serial sections were submitted to low-energy fine-detail radiography, then decalcified sections stained by the WHO method were examined. The preoperative clinical and imaging diagnoses were compared with the pathological findings and special interest was placed on assessing the clinical significance of any unexpected, clinically undetected findings. The most common findings included the presence of bone islands (solitary osteomas) and areas of avascular necrosis in addition to the primary joint disease for which the patient underwent surgery. The preoperative symptomatology did not distinguish between the known primary disease and the additional pathological findings. Some of the clinically unidentified lesions were of a size that fell below the ability of current clinical investigations to detect. However, the finding of lesions by tissue fine-detail radiography indicates that current, more sensitive clinical imaging techniques may identify them. Careful examination of surgically resected femoral heads is important to ensure that all pathologies are identified and assessed for clinical relevance. (orig.)

  4. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    Science.gov (United States)

    Rozkydal, Z; Janíček, P

    2010-08-01

    The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiographic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Six- teen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. The Poldi

  5. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  6. Clinical accuracy of a patient-specific femoral osteotomy guide in minimally-invasive posterior hip arthroplasty.

    Science.gov (United States)

    Schneider, Adrian K; Pierrepont, Jim W; Hawdon, Gabrielle; McMahon, Stephen

    2018-04-01

    Patient specific guides can be a valuable tool in improving the precision of planned femoral neck osteotomies, especially in minimally invasive hip surgery, where bony landmarks are often inaccessible. The aim of our study was to validate the accuracy of a novel patient specific femoral osteotomy guide for THR through a minimally invasive posterior approach, the direct superior approach (DSA). As part of our routine preoperative planning 30 patients underwent low dose CT scans of their arthritic hip. 3D printed patient specific femoral neck osteotomy guides were then produced. Intraoperatively, having cleared all soft tissue from the postero-lateral neck of the enlocated hip, the guide was placed and pinned onto the posterolateral femoral neck. The osteotomy was performed using an oscillating saw and the uncemented hip components were implanted as per routine. Postoperatively, the achieved level of the osteotomy at the medial calcar was compared with the planned level of resection using a 3D/2D matching analysis (Mimics X-ray module, Materialise, Belgium). A total of 30 patients undergoing uncemented Trinity™ acetabular and TriFit TS™ femoral component arthroplasty (Corin, UK) were included in our analysis. All but one of our analysed osteotomies were found to be within 3 mm from the planned height of osteotomy. In one patient the level of osteotomy deviated 5 mm below the planned level of resection. Preoperative planning and the use of patient specific osteotomy guides provides an accurate method of performing femoral neck osteotomies in minimally invasive hip arthroplasty using the direct superior approach. IV (Case series).

  7. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    Science.gov (United States)

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  8. [Total hip endoprosthesis following resection arthroplasty].

    Science.gov (United States)

    Engelbrecht, E; Siegel, A; Kappus, M

    1995-08-01

    From 1976 to December 1994, a total of 347 patients underwent implantation of a hip prosthesis at the ENDO-Klinik for treatment of an unsatisfactory condition following resection arthroplasty. From 1976 to 1987, 143 patients were treated and in 1989 the results obtained in these patients were analysed: 99 of them were available for a follow-up examination in 1989, and 64 for a further examination in 1995. In 130 cases infection had been the reason for joint resection. At the time of the prosthesis operation (1-20 years later) intraoperative biopsy revealed that infection was still present in 41 cases (31.5%). Only 15 of these infections had been detected preoperatively by joint aspiration. This shows that the value of resection arthroplasty as a method of treating periprosthetic infection is limited and lends support to the one-stage exchange operation, which is the method we prefer in cases of infected hip prostheses. The operative technique and preparation for implantation of the prosthesis are described, as are septic and aseptic complications and the measures that can be taken to treat them. In spite of the patients' generally poor initial condition and with due consideration for the further revision operations, the medium-term results finally obtained are poor in only 9%.

  9. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    Science.gov (United States)

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and

  10. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position....

  11. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    Science.gov (United States)

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    Although total hip arthroplasty is one of the most common orthopaedic surgical procedures, it remains unclear whether histopathological examination of the excised femoral head adds to the quality of patient care. We propose that assessment of femoral heads resected during total hip arthroplasty and donated for allograft use may provide a profile of femoral head pathology that benefits total hip arthroplasty patients and bone donors. We retrospectively analyzed the histological findings reported for 6161 femoral heads donated for allograft use between 1993 and 2006. Specimens obtained during total hip arthroplasty and specimens donated at death were reviewed. Follow-up investigations that resulted from abnormal histopathological findings were also reviewed. The Western Australian Cancer Registry was used to determine whether patients with a suspected neoplasm were subsequently diagnosed with such a disease. A retrospective review of the histopathological findings was conducted to evaluate and reclassify all previous observations of abnormalities. One hundred and five femoral heads demonstrated abnormal or reactive histopathological features not reported prior to surgery and were rejected for allograft use. A reactive lymphocytic infiltrate, most likely due to osteoarthritis, was the most commonly identified feature (forty-five cases). Other features observed in twenty-seven cases were also most likely due to the presence of severe osteoarthritis. Ten femoral heads demonstrated plasmacytosis, which may have been related to osteoarthritis. Two patients were diagnosed with Paget's disease, and two, with rheumatoid arthritis. Nineteen patients had a suspected neoplasm. Of these nineteen, eight cases of non-Hodgkin's lymphoma or chronic lymphocytic leukemia and one case of myelodysplastic syndrome were confirmed on further investigation. One subsequently confirmed malignancy was detected per 770 femoral heads examined. Our findings indicate that, even with a detailed

  12. Femoral component loosening after hip resurfacing arthroplasty

    International Nuclear Information System (INIS)

    Zustin, Jozef; Sauter, Guido; Hahn, Michael; Morlock, Michael M.; Ruether, Wolfgang; Amling, Michael

    2010-01-01

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  13. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

    Science.gov (United States)

    Cross, Michael B; Nam, Denis; Mayman, David J

    2012-10-01

    Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed. The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear? A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials. A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data. Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

  14. MR evaluation of the articular cartilage of the femoral head during traction. Correlation with resected femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, K. [Osaka Seamens Insurance Hospital (Japan). Dept. of Radiology; Tanaka, H.; Narumi, Y.; Nakamura, H. [Osaka Univ. Medical School (Japan). Dept. of Radiology; Nishii, T.; Masuhara, K. [Osaka Univ. Medical School (Japan). Dept. of Orthopedic Surgery

    1999-01-01

    Objective: The purpose was to evaluate the articular cartilage of the hip joint with MR during traction and compare the findings with the resected specimen or arthroscopic findings. Material and Methods: Eight healthy volunteers, 5 patients with osteonecrosis, 5 with acetabular dysplasia, and 5 with advanced osteoarthrosis underwent MR imaging to evaluate the articular cartilage of the hip joint. Coronal fat-suppressed 3D spoiled gradient-echo (SPGR) images were obtained during traction. Identical imaging was performed of all the resected femoral heads of the osteonecrosis and advanced osteoarthrosis patients, and was correlated with the macroscopic pathological findings. Results: The traction was effective and the femoral articular cartilage was clearly identified in all 8 control subjects, and in all cases of osteonecrosis and acetabular dysplasia. In 4 cases of osteonecrosis, chondral fracture was identified in the boundary between the necrosis and the normal area. In all cases of advanced osteoarthrosis, cartilage was identified only at the medial side. The MR images of osteonecrosis and advanced osteoarthrosis corresponded well with the MR images of the resected femoral heads and the macroscopic findings. (orig.)

  15. Adductor canal block versus femoral nerve block for analgesia after total knee arthroplasty

    DEFF Research Database (Denmark)

    Jaeger, Pia; Zaric, Dusanka; Fomsgaard, Jonna Storm

    2013-01-01

    Femoral nerve block (FNB), a commonly used postoperative pain treatment after total knee arthroplasty (TKA), reduces quadriceps muscle strength essential for mobilization. In contrast, adductor canal block (ACB) is predominately a sensory nerve block. We hypothesized that ACB preserves quadriceps...

  16. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design i...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  17. Hip resurfacing arthroplasty in treatment of avascular necrosis of the femoral head.

    Science.gov (United States)

    Pyda, Michał; Koczy, Bogdan; Widuchowski, Wojciech; Widuchowska, Małgorzata; Stołtny, Tomasz; Mielnik, Michał; Hermanson, Jacek

    2015-01-25

    Hip resurfacing is a conservative type of total hip arthroplasty but its use is controversial, especially in patients with osteonecrosis. The aim of this study was analysis of the clinical and radiographic outcomes of hip resurfacing in patients with osteonecrosis. Between 2007 and 2008, 30 hip resurfacing arthroplasties were performed due to osteoarthritis secondary to avascular necrosis of femoral head staged as Ficat III and IV. Patients were qualified to resurfacing arthroplasty when the extent of avascular necrosis using Kerboul's method was avascular necrosis and head-neck junction was >20°. All patients were evaluated clinically and radiologically before and 60 months after the operation. The mean Harris Hip Score (HHS) score increased from 47.8 to 94.25 (p<0.05). Physical activity level (University of California, Los Angeles activity score--UCLA activity score) improved from 3.7 to 7.55 (p<0.05). No implant migration was observed. Management of osteonecrosis of the hip with resurfacing arthroplasty seems to be effective in strictly-selected patients.

  18. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  19. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    Science.gov (United States)

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  20. A Case of Acute Prosthesis Migration after Femoral Head Replacement due to Osteomalacia by FGF23-Induced Tumor

    Directory of Open Access Journals (Sweden)

    Shinya Hayashi

    2012-01-01

    Full Text Available Fibroblast growth factor 23 (FGF23 was recently identified as an important factor involved in the development of hypophosphatemic rickets and osteomalacia. We experienced a rare case of acute prosthesis migration after hemihip arthroplasty due to FGF23-induced tumor. The patient underwent femoral head replacement because of femoral neck fracture, but prosthesis migration was occurred at 1 week after operation. The patient took various examinations, and FGF23-induced tumor was found in his right wrist. The tumor was resected, and he underwent total hip arthroplasty 8 month later. Finally, he was able to obtain free gait without pain.

  1. Proximal femoral resection and articulated hip distraction with an external fixator for the treatment of painful spastic hip dislocations in pediatric patients with spastic quadriplegia.

    Science.gov (United States)

    Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R

    2008-01-01

    We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.

  2. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    Science.gov (United States)

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  3. Nontraumatic Fracture of the Femoral Condylar Prosthesis in a Total Knee Arthroplasty Leading to Mechanical Failure

    Directory of Open Access Journals (Sweden)

    Girish N. Swamy

    2014-01-01

    Full Text Available This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA. A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  4. Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure.

    Science.gov (United States)

    Swamy, Girish N; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  5. Resection arthroplasty, external fixation, and negative pressure dressing for first metatarsophalangeal joint ulcers.

    Science.gov (United States)

    Stone, Craig; Smith, Nicholas

    2011-03-01

    A frequent complication for the diabetic patient is neuropathic ulceration on the plantar surface of the first metatarsophalangeal (MTP) joint which can be difficult to manage. Debridement and resection arthroplasty with temporary external fixation and VAC dressing (Kinetic Concepts Inc, San Antonio, TX) is an alternative operative treatment to amputation. This study examined the outcomes of one center's experience with patients who have undergone this procedure. This retrospective cohort study examined patients who underwent the procedure between March 2002 and March 2010. Information was obtained on relevant outcomes including: the initial procedure, secondary procedures on either foot, total time in external fixation, time until amputation, cause of ulceration and co-morbid conditions. During the study period, 16 patients underwent resection arthroplasty with external fixation for first MTP ulceration. Fourteen of these patients had underlying diabetes mellitus, one had Charcot-Marie-Tooth disease and one had neuropathy of unknown cause. All were available for followup at the end of the study period. Median followup was 38 (range, 3 to 96) months. At latest followup, six patients required amputation, either transmetatarsal or transtibial, to treat their recurring ulceration. Resection arthroplasty with temporary external fixation appears to be a safe, effective and possible alternative to amputation for the treatment of neuropathic ulceration of the first MTP.

  6. Arthroscopic sternoclavicular joint resection arthroplasty: a technical note and illustrated case report.

    Science.gov (United States)

    Warth, Ryan J; Lee, Jared T; Campbell, Kevin J; Millett, Peter J

    2014-02-01

    Open resection arthroplasty of the sternoclavicular (SC) joint has historically provided good long-term results in patients with symptomatic osteoarthritis of the SC joint. However, the procedure is rarely performed because of the risk of injury to vital mediastinal structures and concern regarding postoperative joint instability. Arthroscopic decompression of the SC joint has therefore emerged as a potential treatment option because of many recognized advantages including minimal tissue dissection, maintenance of joint stability, avoidance of posterior SC joint dissection, expeditious recovery, and improved cosmesis. There are, however, safety concerns given the proximity of neurovascular structures. In this article we demonstrate a technique for arthroscopic SC joint resection arthroplasty in a 26-year-old active man with bilateral, painful, idiopathic degenerative SC joint osteoarthritis. This case also highlights the pearls and pitfalls of arthroscopic resection arthroplasty for the SC joint. There were no perioperative complications. Four months postoperatively, the patient had returned to full activities, including weightlifting, without pain or evidence of SC joint instability. One year postoperatively, the patient showed substantial improvements in the American Shoulder and Elbow Surgeons score; Single Assessment Numeric Evaluation score; Quick Disabilities of the Arm, Shoulder and Hand score; and Short Form 12 Physical Component Summary score over preoperative baseline values.

  7. Total knee arthroplasty with an oxidised zirconium femoral component: ten-year survivorship analysis.

    Science.gov (United States)

    Ahmed, I; Salmon, L J; Waller, A; Watanabe, H; Roe, J P; Pinczewski, L A

    2016-01-01

    Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome. A total of 303 consecutive TKAs were performed in 278 patients with a mean age of 68 years (45 to 89). The rate of survival ten years post-operatively as assessed using Kaplan-Meier analysis was 97% (95% confidence interval 94 to 99) with revision for any reason as the endpoint. There were no revisions for loosening, osteolysis or failure of the implant. There was a significant improvement in all components of the WOMAC score at final follow-up (p zirconium TKA gives comparable rates of survival with other implants and excellent functional outcomes ten years post-operatively. Total knee arthroplasty with an oxidised zirconium femoral component gives comparable long-term rates of survival and functional outcomes with conventional implants. ©2016 The British Editorial Society of Bone & Joint Surgery.

  8. What is the optimal alignment of the tibial and femoral components in knee arthroplasty?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Korchi, Mounim; Thomsen, Morten G

    2014-01-01

    of positioning on survival and functional outcome was considered. Results - Many definitions exist when evaluating placement of femoral and tibial components. Implant alignment plays a role in both survival and functional outcome following primary TKA, as component malalignment can lead to increased failure......Background - Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature...... describes different definitions of component alignment following primary TKA for (1) tibiofemoral alignment in the AP plane, (2) tibial and femoral component placement in the AP plane, (3) tibial and femoral component placement in the sagittal plane, and (4) rotational alignment of tibial and femoral...

  9. Femoral loosening of high-flexion total knee arthroplasty: The effect of posterior cruciate ligament retention and bone quality reduction

    NARCIS (Netherlands)

    Zelle, J.; van de Groes, S.A.W.; De Waal Malefijt, M.C.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    High-flexion total knee arthroplasty (TKA) may be more sensitive to femoral loosening than conventional TKA as the knee joint force increases during deep flexion. The objective of this study was to evaluate whether the probability of femoral loosening is equal in posterior cruciate ligament (PCL)

  10. Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.

    Science.gov (United States)

    Raman, R; Kamath, R P; Parikh, A; Angus, P D

    2005-08-01

    We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.

  11. Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Robertsson Otto

    2010-08-01

    Full Text Available Abstract Background Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components. Methods We compared the dislocation rate in 56 consecutive patients operated with conventional (single mobility cemented acetabular components to that in 42 consecutive patients operated with dual articulation acetabular components. All the patients were operated via posterior approach and were followed up to one year postoperatively. Results There were 8 dislocations in the 56 patients having conventional components as compared to no dislocations in those 42 having dual articulation components (p = 0.01. The groups were similar with respect to age and gender distribution. Conclusions We conclude that the use of a cemented dual articulation acetabular component significantly reduces the dislocation rates in femoral neck fracture patients operated via posterior approach.

  12. Femoral head and neck excision arthroplasty in a leopard tortoise (Stigmochelys pardalis).

    Science.gov (United States)

    Naylor, Adam D

    2013-12-01

    Cases of femoral head and neck excision arthroplasty are infrequently reported in reptiles, and details of surgical technique and clinical outcome in chelonia are lacking. An adult female leopard tortoise (Stigmochelys pardalis) was presented with chronic non-weight-bearing lameness of the left hind limb. Examination and radiography were consistent with coxofemoral luxation, and as a result of the chronic presentation, surgical intervention was recommended. A cranial approach to the joint via the prefemoral fossa afforded good surgical exposure. A depressed lytic acetabular lesion was noted during the procedure, postulated to be a result of abnormal wear from the luxated femoral head. A fiberglass prop was used during recovery to allow extension of the limb without full weight-bearing. Lameness persisted postoperatively, but limb usage significantly improved.

  13. Outpatient unicompartment knee arthroplasty with indwelling femoral nerve catheter.

    Science.gov (United States)

    Dervin, Geoffrey F; Madden, Susan M; Crawford-Newton, Barbara A; Lane, Alan T; Evans, Holly C

    2012-06-01

    Contemporary multimodal anesthesia regimens allow the performance of unicompartment knee arthroplasty (UKA) on an outpatient basis. Our initial pilot experience is presented using a continuous femoral nerve block as an adjunct for 24 patients classified as American Society of Anesthesiology class 1 (14 men, 10 women; median age, 56 years; range, 46-72 years). After minimally invasive UKA, patients documented their pain and oral medication use while at home for the first 5 days. Adverse events, medication adverse effects, and the amount of infused ropivacaine were recorded. Median pain scores for the first 3 days were 1, 2, and 2 (at rest) and 4, 5, and 3 (during physical therapy). Eighteen patients (75%) required less than 4 mg oral hydromorphone/d. Of the 18, 10 (42%) did not require supplemental oral opioids. The median catheter use was 3 days. Our results suggest that with careful patient selection and adequate teaching, continuous femoral nerve blocks may be used as part of a multimodal pain regimen to assist the delivery of outpatient UKA with high patient satisfaction. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Resection arthroplasty of the hip in paralytic dislocations.

    Science.gov (United States)

    Kalen, V; Gamble, J G

    1984-06-01

    The chronically dislocated paralytic hip causes postural difficulties, nursing and hygiene problems, and pain. Therapeutic options are limited. This study reviews the results of resection arthroplasty on 18 hips of 15 such patients. This procedure has many complications, including hip ankylosis, heterotopic ossification, abduction contracture and bony overgrowth. Despite this, all of the nursing goals were achieved and most patients had relief of pain. The operation is most successful in the skeletally mature patients, and it relies on soft-tissue interposition between the bony fragments and postoperative positioning to ensure optimum posture.

  15. Does exchange arthroplasty of an infected shoulder prosthesis provide better eradication rate and better functional outcome, compared to a permanent spacer or resection arthroplasty? a systematic review.

    Science.gov (United States)

    George, D A; Volpin, A; Scarponi, S; Haddad, F S; Romanò, C L

    2016-02-01

    The best surgical modality for treating chronic periprosthetic shoulder infections has not been established, with a lack of randomised comparative studies. This systematic review compares the infection eradication rate and functional outcomes after single- or two-stage shoulder exchange arthroplasty, to permanent spacer implant or resection arthroplasty. Full-text papers and those with an abstract in English published from January 2000 to June 2014, identified through international databases, such as EMBASE and PubMed, were reviewed. Those reporting the success rate of infection eradication after a single-stage exchange, two-stage exchange, resection arthroplasty or permanent spacer implant, with a minimum follow-up of 6 months and sample size of 5 patients were included. Eight original articles reporting the results after resection arthroplasty (n = 83), 6 on single-stage exchange (n = 75), 13 on two-stage exchange (n = 142) and 8 papers on permanent spacer (n = 68) were included. The average infection eradication rate was 86.7 % at a mean follow-up of 39.8 months (SD 20.8) after resection arthroplasty, 94.7 % at 46.8 months (SD 17.6) after a single-stage exchange, 90.8 % at 37.9 months (SD 12.8) after two-stage exchange, and 95.6 % at 31.0 months (SD 9.8) following a permanent spacer implant. The difference was not statistically significant (p = 0.650). Regarding functional outcome, patients treated with single-stage exchange had statistically significant better postoperative Constant scores (mean 51, SD 13) than patients undergoing a two-stage exchange (mean 44, SD 9), resection arthroplasty (mean 32, SD 7) or a permanent spacer implant (mean 31, SD 9) (p = 0.029). However, when considering studies comparing pre- and post-operative Constant scores, the difference was not statistically significant. This systematic review failed to demonstrate a clear difference in infection eradication and functional improvement between all four

  16. Clinical Outcomes of Gap Balancing vs Measured Resection in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis Involving 2259 Subjects.

    Science.gov (United States)

    Li, Shuxiang; Luo, Xiaomin; Wang, Peng; Sun, Han; Wang, Kun; Sun, Xiaoliang

    2018-03-17

    The argument on the clinical effects between gap balancing (GB) and measured resection (MR) in total knee arthroplasty remains to be resolved. A systematic review and meta-analysis was performed to investigate which technique in total knee arthroplasty has better clinical effect. A total of 20 studies involving 2259 cases were included in the meta-analysis. The primary outcome measure was Knee Society Score (KSS), whereas the secondary outcomes included other function assessment systems (eg, range of motion, Western Ontario and McMaster University Osteoarthritis Index), radiological outcomes (eg, femoral component rotation, total outliers), revision rate, complications (eg, infection, loosening, instability), and surgical time. The GB technique was associated with statistically significant increases in the primary outcomes of KSS-function in 1 year. However, a mean difference of 2.12 points was below the minimal clinically important difference of 6 points. No differences were found in the analyses of KSS-knee and KSS-function in any other follow-up periods. Secondary outcome assessments showed significant decreased surgical time (mean difference, 16.18; P < .00001) for MR. Although statistically significant difference in favor of GB was identified in total outliers (risk ratio, 1.72, P = .0004), the 2 techniques were comparable in range of motion, Western Ontario and McMaster University Osteoarthritis Index, femoral component rotation, complications, and revision rate. We conclude that both techniques can result in equivalent results when done properly, and each surgeon must understand the strengths and weaknesses of each technique. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Femoral sizing in total knee arthroplasty is rotation dependant.

    Science.gov (United States)

    Koninckx, Angelique; Deltour, Arnaud; Thienpont, Emmanuel

    2014-12-01

    The mismatch between the medio-lateral (ML) and the antero-posterior (AP) size of femoral components in total knee arthroplasty (TKA) has been linked to gender, ethnicity, morphotype and height differences in patients. The hypothesis of this study was that the AP size measurement of a femoral component increases with more external rotation in posterior referencing TKA. During a 2-year period, 201 patients were included in this prospective study. The AP distance of the distal femur was measured with an AP sizer of the Vanguard (Biomet, Warsaw, US) knee system. This AP sizer allows to dial in external rotation by 1° increments and to determine the femoral size with an anterior boom. AP size was noted at 0°, 3° and 5° of external rotation and then compared for ML matching. Antero-posterior and corresponding ML sizes match perfectly for the Vanguard at 0° of external rotation and a central boom position on the anterior femoral surface. Then, the anterior boom was positioned on the antero-lateral cortex and the AP size increased a mean (SD) 1 (0.5) mm. With 3° of external rotation, the AP size increased a mean (SD) 2.3 (0.4) mm and for 5° a mean (SD) 3.8 (0.3) mm (P external rotation that is dialled in during surgery. Since these parameters vary case per case, the availability of narrow components offers more surgical options to the surgeon and its importance extends beyond the gender aspect allowing different amounts of external rotation to be used without ML overhang. II.

  18. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  19. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Science.gov (United States)

    Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun

    2015-01-01

    Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634

  20. Bilateral Total Hip Arthroplasty in Femoral Head Avascular Necrosis: Functional Outcomes and Complications

    Directory of Open Access Journals (Sweden)

    Afshin Taheriazam

    2016-06-01

    Full Text Available Total hip arthroplasty (THA is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA offers many benefits. However, there are concerns about the safety of the procedure and higher complications. We aimed to evaluate the complications and outcomes of one-stage BTHA with Hardinge approach for femoral head avascular necrosis patients. A total of 60 patients from April 2009 and May 2013, were underwent one-stage bilateral total hip arthroplasty (BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with femoral head avascular necrosis (AVN performed. We evaluated all patients clinically and radiologically with serial follow-ups. A clinical hip score based upon the modified Harris Hip Score (MHHS was performed preoperatively and again postoperatively. During period of study 44 men (73.3% and 16 women (26.6% with a mean age of 31.40±4.08 years (range 25 to 36 years at the time of presentation were entered. The mean surgical time was 2.6±0.38 hrs. The mean hospital stay was 3 .50±0.72 days. Hemoglobin level decreased significa ntly after operation (P= 0.046. There was no reported patient with perioperative death, deep venous thrombosis, pulmonary embolism, infection, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 47.93±7.33 in patients. MHHS score i mproved to 95.06±3.47 in the last follow-up (P=0.0001.Our results recommend the use of one-stage BTHA through Hardinge approach in femoral head avascular necrosis patients.

  1. [Postoperative analgesia in knee arthroplasty using an anterior sciatic nerve block and a femoral nerve block].

    Science.gov (United States)

    del Fresno Cañiaveras, J; Campos, A; Galiana, M; Navarro-Martínez, J A; Company, R

    2008-11-01

    To evaluate the efficacy of a nerve block as an alternative technique for analgesia after knee arthroplasty and to indicate the usefulness and advantages of the anterior approach to the sciatic nerve block. Between April 2004 and March 2006, we studied a series of consecutive patients undergoing knee arthroplasty in which a subarachnoid block was used as the anesthetic technique and postoperative analgesia was provided by means of a combined peripheral femoral nerve block and an anterior sciatic nerve block. We evaluated the mean length of time free from pain, quality of analgesia, and length of stay in hospital. Seventy-eight patients were included in the study. The mean (SD) length of time free from pain for the group was 42.1 (3.9) hours. Patients reported mild pain after 34.8 (4.1) hours and moderate to severe pain after 42.4 (3.5) hours. By the third day, 62.8% of patients were able to bend the knee to 90 degrees. There were no complications resulting from the technique and the level of patient satisfaction was high. A combined femoral-sciatic nerve block is effective in knee arthroplasty. It controls postoperative pain and allows for early rehabilitation. The anterior approach to the sciatic nerve is relatively simple to perform without removing the pressure bandaging from the thigh after surgery. This approach also makes it unnecessary to move the patient.

  2. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  3. Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients

    Directory of Open Access Journals (Sweden)

    Innocenti Bernardo

    2010-04-01

    Full Text Available Abstract Background The bone mineral density (BMD of the distal femur decreases by 16-36% within one year after total knee arthroplasty (TKA because of the femoral component's stress-shielding effect. The aim of this prospective study was to determine the quantitative change from the baseline BMD in the distal femur 1 year after patellofemoral arthroplasty using dual-energy X-ray absorptiometry (DXA. Methods Between December 2007 and December 2008, 14 patients had patellofemoral arthroplasty for isolated patellofemoral osteoarthritis. Distal femoral BMD was assessed using DXA in 2 regions of interest (ROI on the lateral view 2 weeks before and 12 months after patellofemoral arthroplasty. The contra-lateral knee was used as a control, with BMD measurements performed in identical ROIs. Results The mean change from baseline BMD in the operated knees after 1 year was -0.169 g/cm2 (95% CI: -0.293 to -0.046 g/cm2 behind the anterior flange (-15%, and -0.076 g/cm2 (95% CI: -0.177 to 0.024 g/cm2 in the supracondylar area 1 cm above the prosthesis (-8% (p = 0.01 and p = 0.13, respectively. The mean change from baseline BMD in the non-operated knees after 1 year was 0.016 g/cm2 (95% CI: -0.152 to 0.185 g/cm2 behind the anterior flange (2%, and 0.023 g/cm2 (95% CI: -0.135 to 0.180 g/cm2 in the supracondylar area 1 cm above the prosthesis (2% (p = 0.83, and p = 0.76, respectively. Conclusions Our findings suggest that patellofemoral arthroplasty results in a statistically significant decrease in BMD behind the anterior flange.

  4. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    Science.gov (United States)

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  5. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  6. Ipsilateral femoral autograft reconstruction after resection of a pelvic tumor.

    Science.gov (United States)

    Biau, David J; Thévenin, Fabrice; Dumaine, Valérie; Babinet, Antoine; Tomeno, Bernard; Anract, Philippe

    2009-01-01

    Reconstruction of bone after the resection of a pelvic tumor is challenging. The purpose of the present study was to evaluate the use of the ipsilateral femur as the graft material for reconstruction. We performed a retrospective review of thirteen patients with a malignant pelvic lesion who underwent resection followed by reconstruction with an ipsilateral femoral autograft and insertion of a total hip replacement. The study group included nine men and four women with a median age of fifty-one years at the time of the reconstruction. The diagnosis was chondrosarcoma in eight patients, metastasis in three, and myeloma and radiation-induced malignant disease in one each. The surviving patients were assessed functionally and radiographically; the cumulative probability of revision was estimated while taking into account competing risks. The median duration of follow-up was forty-nine months. At the time of the latest follow-up, seven patients were alive and disease-free and six had died from metastatic disease. Four patients had had revision of the reconstruction, two for the treatment of mechanical complications and two for the treatment of infection. Three other patients had mechanical complications but had not had a revision. The cumulative probability of revision of the reconstruction for mechanical failure was 8% (95% confidence interval, 0% to 23%), 8% (95% confidence interval, 0% to 23%), and 16% (95% confidence interval, 0% to 39%) at one, two, and four years, respectively. Although it has attendant complications consistent with pelvic tumor surgery, an ipsilateral femoral autograft reconstruction may be an option for reconstruction of pelvic discontinuity in a subgroup of patients following tumor resection. This innovative procedure requires longer-term follow-up studies.

  7. Ultrasound and nerve stimulator guided continuous femoral nerve block analgesia after total knee arthroplasty: a multicenter randomized controlled study

    Directory of Open Access Journals (Sweden)

    Fen Wang

    2015-02-01

    Full Text Available BACKGROUND AND OBJECTIVES: Postoperative analgesia is crucial for early functional excise after total knee arthroplasty. To investigate the clinical efficacy of ultrasound and nerve stimulator guided continuous femoral nerve block analgesia after total knee arthroplasty. METHODS: 46 patients with ASA grade I-III who underwent total knee arthroplasty received postoperative analgesia from October 2012 to January 2013. In 22 patients, ultrasound and nerve stimulator guided continuous femoral nerve block were performed for analgesia (CFNB group; in 24 patients, epidural analgesia was done (PCEA group. The analgesic effects, side effects, articular recovery and complications were compared between two groups. RESULTS: At 6 h and 12 h after surgery, the knee pain score (VAS score during functional tests after active exercise and after passive excise in CFNB were significantly reduced when compared with PCEA group. The amount of parecoxib used in CFNB patients was significantly reduced when compared with PCEA group. At 48 h after surgery, the muscle strength grade in CFNB group was significantly higher, and the time to ambulatory activity was shorter than those in PCEA group. The incidence of nausea and vomiting in CFNB patients was significantly reduced when compared with PCEA group. CONCLUSION: Ultrasound and nerve stimulator guided continuous femoral nerve block provide better analgesia at 6 h and 12 h, demonstrated by RVAS and PVAS. The amount of parecoxib also reduces, the incidence of nausea and vomiting decreased, the influence on muscle strength is compromised and patients can perform ambulatory activity under this condition.

  8. [A method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck].

    Science.gov (United States)

    Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang

    2012-03-01

    To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.

  9. Comparison of the Effect of Continuous Femoral Nerve Block and Adductor Canal Block after Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Seo, Seung Suk; Kim, Ok Gul; Seo, Jin Hyeok; Kim, Do Hoon; Kim, Youn Gu; Park, Beyoung Yun

    2017-09-01

    This study aimed to compare the effects of femoral nerve block and adductor canal block on postoperative pain, quadriceps strength, and walking ability after primary total knee arthroplasty. Between November 2014 and February 2015, 60 patients underwent primary total knee arthroplasty. Thirty patients received femoral nerve block and the other 30 received adductor canal block for postoperative pain control. Before spinal anesthesia, the patients received nerve block via a catheter (20 mL 0.75% ropivacaine was administered initially, followed by intermittent bolus injection of 10 mL 0.2% ropivacaine every 6 hours for 3 days). The catheters were maintained in the exact location of nerve block in 24 patients in the femoral nerve block group and in 19 patients in the adductor canal block group. Data collection was carried out from these 43 patients. To evaluate postoperative pain control, the numerical rating scale scores at rest and 45° flexion of the knee were recorded. To evaluate quadriceps strength, manual muscle testing was performed. Walking ability was assessed using the Timed Up and Go test. We also evaluated analgesic consumption and complications of peripheral nerve block. No significant intergroup difference was observed in the numerical rating scale scores at rest and 45° flexion of the knee on postoperative days 1, 2, 3, and 7. The adductor canal block group had significantly greater quadriceps strength than did the femoral nerve block group, as assessed by manual muscle testing on postoperative days 1, 2, and 3. The 2 groups showed no difference in walking ability on postoperative day 1, but on postoperative days 2, 3, walking ability was significantly better in the adductor canal block group than in the femoral nerve block group. No significant intergroup difference was observed in analgesic consumption. The groups showed no difference in postoperative pain control. Adductor canal block was superior to femoral nerve block in preserving quadriceps

  10. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  11. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.

    Science.gov (United States)

    de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico

    2017-11-01

    Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block.

    Science.gov (United States)

    Carvalho Júnior, Lúcio Honório de; Temponi, Eduardo Frois; Paganini, Vinícius Oliveira; Costa, Lincoln Paiva; Soares, Luiz Fernando Machado; Gonçalves, Matheus Braga Jacques

    2015-01-01

    the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  13. Reducing the length of hospital stay after total knee arthroplasty: influence of femoral and sciatic nerve block

    Directory of Open Access Journals (Sweden)

    Lúcio Honório de Carvalho Júnior

    2015-02-01

    Full Text Available Objective: the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. Materials and methods: the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. Results: between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. Conclusion: according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.

  14. Bilateral Simultaneous Femoral Neck Fracture Mimicking Abdominal Pain in a Cerebral Palsy Patient

    Directory of Open Access Journals (Sweden)

    P. Mariani

    2014-01-01

    Full Text Available Simultaneous bilateral femoral neck fractures are unusual lesions, generally associated with an underlying condition which causes impaired bone mineralization, triggered by an increased bone stress. We present a 24-year-old cerebral palsy patient, who was previously evaluated in another institution due to inability to walk, interpreted as abdominal pain. No alteration in blood analysis or abdominal X-rays was found. As no response to treatment was observed, a new abdominal X-ray was taken, which incidentally depicted bilateral medial femoral neck fracture. He was referred to our practice after a resection arthroplasty was offered in another institution. After admission, bilateral one-stage THA was performed. Several reports emphasize bone disease as a major precipitating factor, and there is an increased incidence of hip fractures in chronic epilepsy, renal osteodystrophy, and chronic steroid use. Femoral head resection has been proven to be effective in immobilized patients, whereas this was not a reasonable option in this patient who presented walking ability. Despite the treatment election, primary care physicians should be aware of and alert to the possibility of fractures in patients with neurological disorders and calcium metabolism alterations. Late diagnosis of orthopedic injuries in this type of patients may lead to permanent disability.

  15. Posterior Femoral Single Limb Osteotomy for the Removal of Well-Fixed Modular Femoral Neck Components

    Directory of Open Access Journals (Sweden)

    Keith A Fehring

    2017-07-01

    Full Text Available Modular neck femoral components were introduced to optimize femoral neck anteversion, leg length, offset, and stability in total hip arthroplasty. However, concerns have been raised in recent years regarding early failure of these implants due to corrosion, pseudotumor, as well as fracture of the modular neck. Removing modular neck femoral implants is challenging as removal of the modular femoral neck leaves a proximally coated femoral stem level with the proximal bone of the femoral neck. We describe a posterior femoral single limb osteotomy  (posterior cut of an extended trochanteric osteotomy for the removal of a modular neck femoral component.

  16. Ultrasound-guided Radiofrequency Lesioning of the Articular Branches of the Femoral Nerve for the Treatment of Chronic Post-arthroplasty Hip Pain.

    Science.gov (United States)

    Kim, David J; Shen, Shiqian; Hanna, George M

    2017-02-01

    Total hip arthroplasty (THA) is a common surgical treatment for several conditions of the hip. While the majority of patients obtain satisfactory results, many develop chronic post-arthroplasty hip pain that can be difficult to treat. We evaluate the effectiveness of cooled (60°C) radiofrequency lesioning of the articular branches of the femoral nerve (ABFN) as a minimally invasive treatment for patients suffering from chronic post-arthroplasty hip pain. This treatment has never been described previously in this population. Case report. Center for Pain Medicine, Massachusetts General Hospital, Harvard Medical School. A 59-year-old woman with long-standing osteoarthritis of the right hip who underwent primary total hip arthroplasty and presented with chronic post-arthroplasty hip pain Intervention: Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance Outcome Measure: Functional ability and numeric rating scale (NRS) scores at rest and with activity. Prior to intervention, the patient reported severe disruption in daily activities, sleep, and relationships; NRS scores at rest and with activity were 4/10 and 10/10, respectively. At 4 weeks following intervention, the patient reported significant improvement in functional ability and NRS scores decreased to 1/10 and 2/10, respectively. At 6 months, the patient's NRS scores at rest and with activity were 0/10 and 1/10, respectively. At 24-month follow-up, the patient continued to endorse significant pain relief with NRS scores at rest and with activity of 0 - 1/10 and 1 - 2/10, respectively. There were no side effects or complications including motor weakness, sensory loss, and neuralgias. Although the patient obtained good results from the intervention, the description of the study is from a single case report. Further study is necessary to investigate the widespread use of this technique and its outcomes. Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance is both an

  17. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis.

    Science.gov (United States)

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A M; Fiorentini, Carlo E; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M

    2017-12-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year.

  18. [Dexmedetomidine combined with ropivacaine for continuous femoral nerve block improved postoperative sleep quality in elderly patients after total knee arthroplasty].

    Science.gov (United States)

    Wang, X L; Wang, J; Mu, D L; Wang, D X

    2018-03-13

    Objective: To investigate the effect of dexmedetomidine adding to ropivacaine for continuous femoral nerve block on the improvement of postoperative sleep quality in elderly patients after total knee arthroplasty. Methods: One hundred and sixty patients aged 60 years or older in Jishuitan Hospital scheduled for single total knee arthroplasty between Nov. 2016 and Jun. 2017 were recruited. All patients received spinal anesthesia and were randomized to receive either combined ropivacaine and dexmedetomidine (0.2% ropivacaine 250 ml and 5 μg/kg dexmedetomidine, at a rate of 5 ml/h or 0.1 μg·kg -1 ·h -1 dexmedetomidine, dexmedetomidine group) or only ropivacaine (0.2% ropivacaine, at a rate of 5 ml/h, controlled group) for continuous femoral nerve block as postoperative analgesia after surgery. The severity of postoperative pain was assessed with numeric rating scale at 4, 24, and 48 hours after surgery both at rest and with movement. Subjective sleep quality and delirium were evaluated daily during the first 3 days postoperatively. Results: The subjective sleep quality scores were 2(1-4), 2(1-4) and 4(2-8), 4(2-7) in dexmedetomidine group and controlled group respectively on the 1st and 2nd days after surgery. The scores of dexmedetomidine group were much better than those of controlled group ( Z =-4.597, -4.183, both P quality, postoperative analgesia, and reduce delirium in the elderly after total knee arthroplasty.

  19. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Instability after total hip arthroplasty

    Science.gov (United States)

    Werner, Brian C; Brown, Thomas E

    2012-01-01

    Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Non-operative management is often successful if the components are well-fixed and correctly positioned in the absence of neurocognitive disorders. If conservative management fails, surgical options include revision of malpositioned components; exchange of modular components such as the femoral head and acetabular liner; bipolar arthroplasty; tripolar arthroplasty; use of a larger femoral head; use of a constrained liner; soft tissue reinforcement and advancement of the greater trochanter. PMID:22919568

  1. The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.

    Science.gov (United States)

    Wegrzyn, Julien; Roux, Jean-Paul; Loriau, Charlotte; Bonin, Nicolas; Pibarot, Vincent

    2018-02-22

    Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions. One hundred fifty-one CT scans of adult healthy hips were obtained from 151 male Caucasian patients (mean age = 66 ± 11 years) undergoing lower limb CT scan arteriography. Tridimensional PF reconstructions and parameter measurements were performed using a corrected PF coronal plane-defined by the femoral neck and diaphyseal canal longitudinal axes-to avoid influence of PF helitorsion and femoral neck version on extramedullary PF parameters. Independently of the femoral neck-shaft angle, the PFMV was significantly and positively correlated with the FO, FNL, and FHH (r = 0.407 to 0.420; p < 0.0001). This study emphasized that the tridimensional PF geometry measurement in the corrected coronal plane of the femoral neck can be useful to determine and optimize the design of a non-modular cementless femoral stem. Particularly, continuous homothetic size progression of the intra- and extramedullary PF parameters should be achieved to assure stem fixation and restore anatomic hip biomechanics.

  2. An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty.

    Science.gov (United States)

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi

    2013-05-01

    Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A Huge Capital Drop with Compression of Femoral Vessels Associated with Hip Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Tomoya Takasago

    2015-01-01

    Full Text Available A capital drop is a type of osteophyte at the inferomedial portion of the femoral head commonly observed in hip osteoarthritis (OA, secondary to developmental dysplasia. Capital drop itself is typically asymptomatic; however, symptoms can appear secondary to impinge against the acetabulum or to irritation of the surrounding tissues, such as nerves, vessels, and tendons. We present here a case of unilateral leg edema in a patient with hip OA, caused by a huge bone mass occurring at the inferomedial portion of the femoral head that compressed the femoral vessels. We diagnosed this bone mass as a capital drop secondary to hip OA after confirming that the mass occurred at least after the age of 63 years based on a previous X-ray. We performed early resection and total hip arthroplasty since the patient’s hip pain was due to both advanced hip OA and compression of the femoral vessels; moreover, we aimed to prevent venous thrombosis secondary to vascular compression considering the advanced age and the potent risk of thrombosis in the patient. A large capital drop should be considered as a cause of vascular compression in cases of unilateral leg edema in OA patients.

  4. Liposomal bupivacaine infiltration versus femoral nerve block for pain control in total knee arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Ma, Jianbing; Zhang, Weijie; Yao, Shuxin

    2016-12-01

    Total knee arthroplasty (TKA) usually results in postoperative pain. The objective of this meta-analysis was to compare the effectiveness and safety of liposomal bupivacaine (LB) infiltration and femoral nerve block (FNB) for pain control in total knee arthroplasty. We systemically searched electronic databases, including Embase (1980-2016.7), MEDLINE (1966-2016.7), PubMed (1966-2016.7), ScienceDirect (1985-2016.7), Web of Science (1950-2016.7) and Cochrane Library for potentially relevant articles. All calculations were conducted using Stata 11.0. One randomized controlled trials (RCTs) and five non-RCTs involving 1289 participants met the inclusion criteria. The result of the meta-analysis revealed that there were no significant differences in terms of postoperative pain scores at POD 0 (SMD = -0.047, 95% CI: -0.276 to 0.182, P = 0.688), POD1 (SMD = -0.038, 95% CI: -0.273 to 0.197, P = 0.749) or POD 2 (SMD = -0.043, 95% CI: -0.192 to 0.107, P = 0.575). Significant differences were found between groups in morphine equivalent consumption at POD 1 (SMD = 0.625, 95% CI: 0.068 to 1.183, P = 0.028) and POD 2 (SMD = 0.410, 95% CI: 0.024 to 0.796, P = 0.037) between groups. There were no significant differences regarding the incidence of adverse effects such as nausea (RD = -0.01, 95% CI: -0.04 to -0.075, P = 0.914) or vomiting (RD = 0.006, 95% CI: -0.049 to 0.062, P = 0.821). Liposomal bupivacaine infiltration provides similar postoperative pain relief to femoral nerve block following total knee arthroplasty. In addition, liposomal bupivacaine infiltration could significantly reduce the consumption of morphine equivalents compared to femoral nerve block without an increased risk of adverse events. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  5. The use of interlocking prostheses for both temporary and definitive management of infected periprosthetic femoral fractures.

    Science.gov (United States)

    Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S

    2011-12-01

    Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Zerahn, Bo; Borgwardt, Lotte; Ribel-Madsen, Søren

    2011-01-01

    in all Gruen zones with the largest declines in group D. BMD changes in Gruen zones 1, 2, 3, 6, and 7 correlated with height, and body weight. Advanced age was associated with an increase in bone loss in Gruen zones 1, 2, 3, 6, and 7. A large stem size was associated with a decline in BMD in Gruen zones......Abstract: We performed a study to assess whether different bearing materials have an impact on femoral bone remodeling within the first four years after a hybrid total hip arthroplasty. 205 of 300 patients were available for 4 years follow-up after being randomly allocated to four prosthetic...... 1, 6, and 7.Bone remodeling after total hip arthroplasty may depend on the composition of bearing materials, but age, height, weight, and stem size are also related to changes in BMD....

  7. Osteoarthritis of the patella, lateral femoral condyle and posterior medial femoral condyle correlate with range of motion.

    Science.gov (United States)

    Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki

    2013-11-01

    The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.

  8. Risk factors for post-operative periprosthetic fractures following primary total hip arthroplasty with a proximally coated double-tapered cementless femoral component

    DEFF Research Database (Denmark)

    Gromov, K; Bersang, A; Nielsen, C S

    2017-01-01

    ratio were recorded post-operatively. Periprosthetic fractures were identified and classified according to the Vancouver classification. Regression analysis was performed to identify risk factors for early periprosthetic fracture. RESULTS: The mean follow-up was 713 days (1 to 2058). A total of 48......AIMS: The aim of this study was to identify patient- and surgery-related risk factors for sustaining an early periprosthetic fracture following primary total hip arthroplasty (THA) performed using a double-tapered cementless femoral component (Bi-Metric femoral stem; Biomet Inc., Warsaw, Indiana...... periprosthetic fractures (3.0%) were identified during the follow-up and median time until fracture was 16 days, (interquartile range 10 to 31.5). Patients with femoral Dorr type C had a 5.2 times increased risk of post-operative periprosthetic fracture compared with type B, while female patients had a near...

  9. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study

    NARCIS (Netherlands)

    P.T.P.W. Burgers (Paul); M. Hoogendoorn (Martine); E.A.C. Van Woensel; R.W. Poolman (Rudolf); M. Bhandari (Mohit); P. Patka (Peter); E.M.M. van Lieshout (Esther)

    2016-01-01

    textabstractSummary: The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost

  10. Femoral neck buttressing: a radiographic and histologic analysis

    International Nuclear Information System (INIS)

    Dixon, T.; Benjamin, J.; Lund, P.; Graham, A.; Krupinski, E.

    2000-01-01

    Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture.Conclusion. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing. (orig.)

  11. Effect of medial–lateral malpositioning of the femoral component in total knee arthroplasty on anterior knee pain at greater than 8 years of follow-up

    NARCIS (Netherlands)

    van de Groes, S.A.W.; Koëter, S.; De Waal Malefijt, M.C.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background The trochlea is often medialized after total knee arthroplasty (TKA) resulting in abnormal patellar tracking, which may lead to anterior knee pain. However, due to the difference in shape of the natural trochlea and the patellar groove of the femoral component, a medialization of the

  12. Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

    Science.gov (United States)

    Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi

    2018-05-01

    This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.

  13. Internal-external malalignment of the femoral component in kinematically aligned total knee arthroplasty increases tibial force imbalance but does not change laxities of the tibiofemoral joint.

    Science.gov (United States)

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by  2° and 4° of internal-external (I-E) malalignment of the femoral component in kinematically aligned total knee arthroplasty. Because I-E malalignment would introduce the greatest changes to the articular surfaces near 90° of flexion, the hypotheses were that the tibial force imbalance would be significantly increased near 90° flexion and that primarily varus-valgus laxity would be affected near 90° flexion. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced I-E malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured from 0° to 120° flexion using a custom tibial force sensor. Bidirectional laxities in four degrees of freedom were measured from 0° to 120° flexion using a custom load application system. Tibial force imbalance increased the greatest at 60° flexion where a regression analysis against the degree of I-E malalignment yielded sensitivities (i.e. slopes) of 30 N/° (medial tibial force > lateral tibial force) and 10 N/° (lateral tibial force > medial tibial force) for internal and external malalignments, respectively. Valgus laxity increased significantly with the 4° external component with the greatest increase of 1.5° occurring at 90° flexion (p < 0.0001). With the tibial component correctly aligned, I-E malalignment of the femoral component caused significant increases in tibial force imbalance. Minimizing I-E malalignment lowers the increase in the tibial force imbalance. By keeping

  14. Influences of continuous femoral nerve block on knee function and quality of life in patients following total knee arthroplasty.

    Science.gov (United States)

    Wang, Fen; Zhou, Yingjie; Sun, Jiajun; Yang, Chunxi

    2015-01-01

    Continuous femoral nerve block (CFNB), guided by ultrasound combined nerve stimulations, offers advantages for both sides and provides effective postoperative analgesia after total knee arthroplasty (TKA). The objective of this study was to evaluate the medium-term impact of continuous femoral nerve block on knee function and quality of life in patients following TKA. This was a follow-up study. Total 168 adult patients scheduled for elective TKA were randomly allocated to receive postoperative continuous femoral nerve block guided by ultrasound combined nerve stimulator (group CFNB, n = 82) or patient-controlled epidural analgesia (group PCEA, n = 86). Quality of life, knee function, patient satisfaction, pain medication and associated adverse effects were compared at 1, 3, 6, and 12 months postoperatively. Quality of life was assessed using the Medical Outcomes Study Short Form-36 Health Survey (MOS SF-36), and clinical results were assessed using the Hospital for Special Surgery (HSS) Knee Scoring System. Patient satisfaction scores were divided into four categories. A total of 162 patients completed the 12-month follow-up. The CFNB group patients had significantly improved SF-36 scores and physical function at 1 month postoperatively (P quality of life in patients at one month postoperatively. Continuous femoral nerve block is a good choice for postoperative analgesia after TKA.

  15. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

      Background and purpose: Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type...... was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising...

  16. Urinary retention in unilateral total knee arthroplasty: comparison between continuous epidural analgesia and single-shot femoral nerve block

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, R.I.

    2018-01-01

    To compare the frequency of urinary retention and requirement of bladder catheterization in patients undergoing toatal knee arthroplasty while receiving either continuous epidural analgesia or single-shot femoral nerve block. Study Design: Randomized controlled study. Place and Duration of Study:Operating Rooms of Aga Khan University Hospital, Karachi, from January 2014 to January 2015. Methodology:Patients were randomized in two groups of 30 each, i.e. epidural group (group E) or femoral nerve block group (group F). Baseline parameters were recorded. Postoperatively, patients were followed for upto 24 hours to collect the data regarding urinary retention. Final outcome was taken at 24 hours postoperatively. Data was analyzed to compare the frequency of urinary retention between the two groups. Results:The average age of the patients was 59.58 +-5.85 years. There were 28 (46.7%) male and 32 (53.3%) female patients. Frequency of urinary retention was significantly high in Group E than Group F (46.7% vs. 6.7%; p=0.0005). Conclusion: Single-shot femoral nerve block offers a more favorable profile in terms of postoperative urinary retention when compared to continuous epidural analgesia. (author)

  17. Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Park, Kyung Soon; Diwanji, Sanket R; Kim, Hyung Keun; Song, Eun Kyoo; Yoon, Taek Rim

    2009-08-01

    Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.

  18. Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair

    Directory of Open Access Journals (Sweden)

    Lorenzo Fagotti

    2015-12-01

    Full Text Available ABSTRACT The aim here was to report a case of a young adult patient who evolved with tumor formation in the left thigh, 14 years after revision surgery on hip arthroplasty. Davies in 2005 made the first description of this disease in patients undergoing metal-on-metal hip arthroplasty. Over the last decade, however, pseudotumors around metal-on-polyethylene surfaces have become more prevalent. Our patient presented with increased volume of the left thigh 8 years after hip arthroplasty revision surgery. Two years before the arising of the tumor in the thigh, a nodule in the inguinal region was investigated to rule out a malignant neoplastic process, but the results were inconclusive. The main preoperative complaints were pain, functional limitation and marked reduction in the range of motion of the left hip. Plain radiographs showed loosening of acetabular and femoral, and a large mass between the muscle planes was revealed through magnetic resonance imaging of the left thigh. The surgical procedure consisted of resection of the lesion and removal of the components through lateral approach. In respect of total hip arthroplasty, pseudotumors are benign neoplasms in which the bearing surface consists of metal-on-metal, but they can also occur in different tribological pairs, as presented in this case.

  19. Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

    Science.gov (United States)

    Al-Amiry, Bariq; Mahmood, Sarwar; Krupic, Ferid; Sayed-Noor, Arkan

    2017-09-01

    Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

  20. The Frank Stinchfield Award : Total Hip Arthroplasty for Femoral Neck Fracture Is Not a Typical DRG 470: A Propensity-matched Cohort Study.

    Science.gov (United States)

    Schairer, William W; Lane, Joseph M; Halsey, David A; Iorio, Richard; Padgett, Douglas E; McLawhorn, Alexander S

    2017-02-01

    Hip fractures are a major public health concern. For displaced femoral neck fractures, the needs for medical services during hospitalization and extending beyond hospital discharge after total hip arthroplasty (THA) may be different than the needs after THA performed for osteoarthritis (OA), yet these differences are largely uncharacterized, and the Medicare Severity Diagnosis-Related Groups system does not distinguish between THA performed for fracture and OA. (1) What are the differences in in-hospital and 30-day postoperative clinical outcomes for THA performed for femoral neck fracture versus OA? (2) Is a patient's fracture status, that is whether or not a patient has a femoral neck fracture, associated with differences in in-hospital and 30-day postoperative clinical outcomes after THA? The National Surgical Quality Improvement Program (NSQIP) database, which contains outcomes for surgical patients up to 30 days after discharge, was used to identify patients undergoing THA for OA and femoral neck fracture. OA and fracture cohorts were matched one-to-one using propensity scores based on age, gender, American Society of Anesthesiologists grade, and medical comorbidities. Propensity scores represented the conditional probabilities for each patient having a femoral neck fracture based on their individual characteristics, excluding their actual fracture status. Outcomes of interest included operative time, length of stay (LOS), complications, transfusion, discharge destination, and readmission. There were 42,692 patients identified (41,739 OA; 953 femoral neck fractures) with 953 patients in each group for the matched analysis. For patients with fracture, operative times were slightly longer (98 versus 92 minutes, p = 0.015), they experienced longer LOS (6 versus 4 days, p group (2.0% versus 0.2%, p = 0.002), the frequency of postoperative transfusion was not different between groups (27% versus 24%, p = 0.157). Having a femoral neck fracture versus OA was

  1. Patient-oriented functional results of total femoral endoprosthetic reconstruction following oncologic resection.

    Science.gov (United States)

    Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C

    2011-11-01

    Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.

  2. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    Total knee arthroplasty often results in marked postoperative pain. A recent meta-analysis supports the use of femoral nerve block or alternatively spinal injection of morphine plus local anaesthetic for post-operative analgesia. On the other hand, the use of intrathecal morphine may be associated with a large number of distressing side effects (itching, urinary retention, nausea and vomiting, delayed respiratory depression). The aim of this study was to compare the effectiveness of femoral nerve block and low dose intrathecal morphine in post-operative analgesia after primary unilateral total knee arthroplasty. Fifty-two consecutive patients scheduled for primary unilateral total knee arthroplasty were allocated to the intrathecal morphine group (ITM group) or to the femoral nerve block group (FNB group). In ITM group a subarachnoid puncture was performed at the L3-L4 inter-vertebral space with hyperbaric bupivacaine 15 mg plus 100 mcg of preservative-free morphine. Patients allocated to the FNB group received a single-injection ultrasound-assisted femoral nerve block with ropivacaine 0.75% 25 ml before the spinal injection of hyperbaric bupivacaine 15 mg. All patients received postoperative patient-controlled-analgesia (PCA) morphine, using a 1-mg bolus and a 5-minute lockout period. Data were analyzed using Student t test or two-way analysis of variance (ANOVA) for repeated measures with time and treatment as the 2 factors. Post hoc comparisons were performed by Bonferroni test. Statistical significance for all test was a p value < 0.05. Patient characteristics were similar between the 2 groups. We found a statistically significant differences in postoperative pain between the two groups: ITM group had the lower visual analogic pain score (VAS) values. Morphine consumption was lower in the ITM group: average consumption within the first 6 hours was 0.9 mg in IT group compared to 3.1 mg in FNB group; at 12 h 4.2 mg vs 6.3 mg; at 24 h 6.9 mg vs 10.3 mg; at 48 h 9

  3. Radiology in Gerard uncemented double cup arthroplasty

    International Nuclear Information System (INIS)

    Willems, W.J.; Rozing, P.M.; Obermann, W.R.

    1988-01-01

    A radiological follow-up was performed on 109 Gerard (uncemented) double cup arthroplasties, with special emphasis on shift of the femoral cup and protrusion of the acetabular cup, for which a new formula was introduced. Varus shift or axial collapse of the femoral cup played a major role in the failure of these cups. Fluoroscopic examination with video-tape recording seemed to be most helpful in determining abnormalities in this kind of arthroplasty. This examination revealed one normal and two abnormal types of movement, either between both cups or between acetabular cup and acetabular cavity. Those hips with normal movement showed a significantly better clinical score. 16 refs.; 6 figs

  4. The Effect of Femoral Cutting Guide Design Improvements for Patient-Specific Instruments

    Directory of Open Access Journals (Sweden)

    Oh-Ryong Kwon

    2015-01-01

    Full Text Available Although the application of patient-specific instruments (PSI for total knee arthroplasty (TKA increases the cost of the surgical procedure, PSI may reduce operative time and improve implant alignment, which could reduce the number of revision surgeries. We report our experience with TKA using PSI techniques in 120 patients from March to December 2014. PSI for TKA were created from data provided by computed tomography (CT scans or magnetic resonance imaging (MRI; which imaging technology is more reliable for the PSI technique remains unclear. In the first 20 patients, the accuracy of bone resection and PSI stability were compared between CT and MRI scans with presurgical results as a reference; MRI produced better results. In the second and third groups, each with 50 patients, the results of bone resection and stability were compared in MRI scans with respect to the quality of scanning due to motion artifacts and experienced know-how in PSI design, respectively. The optimized femoral cutting guide design for PSI showed the closest outcomes in bone resection and PSI stability with presurgical data. It is expected that this design could be a reasonable guideline in PSI.

  5. Endotoxins in surgical instruments of hip arthroplasty

    OpenAIRE

    Goveia, Vania Regina; Mendoza, Isabel Yovana Quispe; Guimarães, Gilberto Lima; Ercole, Flavia Falci; Couto, Bráulio Roberto Gonçalves Marinho; Leite, Edna Marilea Meireles; Stoianoff, Maria Aparecida Resende; Ferreira, José Antonio Guimarães

    2016-01-01

    Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60...

  6. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995)

    International Nuclear Information System (INIS)

    Edwards, M.R.; Egger, E.L.; Schwarz, P.D.

    1997-01-01

    Objective-To determine clinical signs, radiographic findings, results of surgical management, and potential causes of aseptic loosening of the femoral implant (ALFI) in dogs that have undergone cemented total hip arthroplasty (THA). Design-Retrospective study. Animals-11 cases of ALFI in 10 dogs. Procedure-Medical records of all dogs undergoing THA revision surgery were reviewed. Only dogs with ALFI were included. The prosthesis and cement were removed by creating a longitudinal osteotomy of the cranial femoral cortex. Postoperative radiographs of all dogs that underwent THA during the study period were reviewed. Results-The most common clinical sign was intermittent, subtle. or non-weight-bearing lameness. On radiographs obtained after THA, contact of the distal stem tip with cortical endosteum was evident in all dogs. Radiographic changes at the time of diagnosis of ALFI included asymmetric periosteal reaction along the femoral diaphysis, radiolucent lines between the prosthesis and cement, altered implant position, and femoral fracture. Surgical revision yielded good or excellent results in 9 cases. In 1 dog. the implant became infected; in another, aseptic loosening recurred. Aseptic loosening was significantly more common in dogs in which there was contact between the distal stem tip and cortical endosteum than in dogs in which there was no contact. Clinical Implications-ALFI is an uncommon, but important, complication of THA, and radiography is warranted in dogs with clinical signs of ALFI. Initial centering of the prosthetic stem within the femoral shaft may reduce the incidence of ALFI

  7. Hip Fractures and the Bundle: A Cost Analysis of Patients Undergoing Hip Arthroplasty for Femoral Neck Fracture vs Degenerative Joint Disease.

    Science.gov (United States)

    Grace, Trevor R; Patterson, Joseph T; Tangtiphaiboontana, Jennifer; Krogue, Justin D; Vail, Thomas P; Ward, Derek T

    2018-06-01

    The purpose of this study is to determine whether episode Target Prices in the Bundled Payment for Care Improvement (BPCI) initiative sufficiently match the complexities and expenses expected for patients undergoing hip arthroplasty for femoral neck fracture (FNF) as compared to hip degenerative joint disease (DJD). Claims data under BPCI Model 2 were collected for patients undergoing hip arthroplasty at a single institution over a 2-year period. Payments from the index hospitalization to 90 days postoperatively were aggregated by Medicare Severity Diagnosis-Related Group (469 or 470), indication (DJD vs FNF), and categorized as index procedure, postacute services, and related hospital readmissions. Actual episode costs and Target Prices were compared in both the FNF and DJD cohorts undergoing hip arthroplasty to gauge the cost discrepancy in each group. A total of 183 patients were analyzed (31 with FNFs, 152 with DJD). In total, the FNF cohort incurred a $415,950 loss under the current episode Target Prices, whereas the DJD cohort incurred a $172,448 gain. Episode Target Prices were significantly higher than actual episode prices for the DJD cohort ($32,573 vs $24,776, P expenses incurred by FNF patients undergoing hip arthroplasty. Better risk-adjusting Target Prices for this fragile population should be considered to avoid disincentives and delays in care. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. [Pelvic reconstructions after bone tumor resection].

    Science.gov (United States)

    Anract, Philippe; Biau, David; Babinet, Antoine; Tomeno, Bernard

    2014-02-01

    The three more frequent primitive malignant bone tumour which concerned the iliac bone are chondrosarcoma, following Ewing sarcoma and osteosarcoma. Wide resection remains the most important part of the treatment associated with chemotherapy for osteosarcoma and the Ewing sarcoma. Iliac wing resections and obdurate ring don't required reconstruction. However, acetabular resections and iliac wing resection with disruption of the pelvic ring required reconstruction to provide acceptable functional result. Acetabular reconstruction remains high technical demanding challenge. After isolated acetabular resection or associated to obdurate ring, our usual method of reconstruction is homolateral proximal femoral autograft and total hip prosthesis but it is possible to also used : saddle prosthesis, Mac Minn prosthesis with auto or allograft, modular prosthesis or custom made prosthesis, massive allograft with or without prosthesis and femoro-ilac arthrodesis. After resection of the iliac wing plus acetabulum, reconstruction can be performed by femoro-obturatrice and femora-sacral arthrodesis, homolateral proximal femoral autograft and prosthesis, femoral medialisation, massive allograft and massive allograft. Carcinological results are lesser than resection for distal limb tumor, local recurrence rate range 17 to 45%. Functional results after Iliac wing and obdurate ring are good. However, acetabular reconstruction provide uncertain functional results. The lesser results arrive after hemipelvic or acetabular and iliac wing resection-reconstruction, especially when gluteus muscles were also resected. The most favourable results arrive after isolated acetabular or acetabular plus obturateur ring resection-reconstruction.

  9. Total knee arthroplasty using patient-specific blocks after prior femoral fracture without hardware removal

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2018-01-01

    Full Text Available Background: The options to perform total knee arthroplasty (TKA with retained hardware in femur are mainly – removal of hardware, use of extramedullary guide, or computer-assisted surgery. Patient-specific blocks (PSBs have been introduced with many potential advantages, but their use in retained hardware has not been adequately explored. The purpose of the present study was to outline and assess the usefulness of the PSBs in performing TKA in patients with retained femoral hardware. Materials and Materials and Methods: Nine patients with retained femoral hardware underwent TKA using PSBs. All the surgeries were performed by the same surgeon using same implants. Nine cases (7 males and 2 females out of total of 120 primary TKA had retained hardware. The average age of the patients was 60.55 years. The retained hardware were 6 patients with nails, 2 with plates and one patient had screws. Out of the nine cases, only one patient needed removal of a screw which was hindering placement of pin for the PSB. Results: All the patients had significant improvement in their Knee Society Score (KSS which improved from 47.0 to postoperative KSS of 86.77 (P < 0.00. The mechanical axis was significantly improved (P < 0.03 after surgery. No patient required blood transfusion and the average tourniquet time was 41 min. Conclusion: TKA using PSBs is useful and can be used in patients with retained hardware with good functional and radiological outcome.

  10. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  11. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. The quality of life after a femoral neck fracture in elderly patients: a comparative study between internal fixation and arthroplasties

    Directory of Open Access Journals (Sweden)

    Dennis Sansanovicz

    2017-01-01

    Full Text Available Introduction: The femoral neck fracture is a frequent pathology in the elderly population, with about of 100,000 cases per year in Brazil. The surgical treatment by internal fixation or arthroplastic hip replacement is advocated today. The non-surgical treatment is reserved for cases of exception. Objective: To compare the quality of patient postoperative life treated for femoral neck fracture by two different techniques: hip arthroplasty and internal fixation. Methods: Through the SF-36 questionnaire, we study the quality of life of 60 patients with more than 65 years, treated between 2004 and 2012 in our service. Half of the patients was submitted to internal fixation and the other half to the arthroplastic replacement. Results: Higher averages in the large majority of the parameters of the questionnaire were obtained by the group which was carried out by internal fixation, but without statistical significance in most of these differences. Some international reports indicate that patients who have suffered a fracture of the femoral neck and were treated with internal fixation may recover the quality of life they had before the fracture. Paradoxically, there is a growing trend among orthopedic surgeons to perform a hip replacement surgery in these cases. Conclusion: Further studies are needed to define which is the best surgical treatment option.

  13. Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.

    Science.gov (United States)

    Saffo, Zaid; Ognjan, Anthony

    2016-01-01

    The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a

  14. Recurrent hemarthrosis after total knee arthroplasty

    NARCIS (Netherlands)

    Rukavina, A.; Kerkhoffs, G.M.M.J.; Schneider, P.; Kuster, M.S.

    2010-01-01

    This report describes a case of spontaneous recurrent hemarthrosis of the knee that presented 4 weeks after total knee arthroplasty. Femoral arteriography showed a false aneurysm of a branch of the inferior lateral geniculate artery. Therapeutic embolization of the arterial branch was performed

  15. Comparison of hip function and quality of life of total hip arthroplasty and resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint at 5 years.

    Science.gov (United States)

    Costa, Matthew L; Achten, Juul; Foguet, Pedro; Parsons, Nicholas R

    2018-03-12

    To compare the medium-term clinical effectiveness of total hip arthroplasty and resurfacing arthroplasty. Single centre, two-arm, parallel group, assessor blinded, randomised controlled trial with 1:1 treatment allocation. A large teaching hospital in England. 122 patients older than 18 years with severe arthritis of the hip joint, suitable for resurfacing arthroplasty of the hip. Patients were excluded if they were considered to be unable to adhere to trial procedures or complete questionnaires. Total hip arthroplasty (replacement of entire femoral head and neck); hip resurfacing arthroplasty (replacement of the articular surface of femoral head only, femoral neck remains intact). Both procedures replaced the articular surface of the acetabulum. The outcome measures were hip function assessed using the Oxford Hip Score (OHS) and health-related quality of life assessed using the EuroQol (EQ-5D). Patients were followed up annually for a minimum of 5 years. Outcome data were modelled using the generalised estimating equation methodology to explore temporal variations during follow-up. 60 patients were randomly assigned to hip resurfacing arthroplasty and 62 to total hip arthroplasty. 95 (78%) of the 122 original study participants provided data at 5 years. There was a small decrease in both hip functions and quality of life in both groups of patients each year during the 5-year follow-up period. However, there was no evidence of a significant difference between treatments group in the OHS (P=0.333) or the EQ-5D (P=0.501). We previously reported no difference in outcome in the first year after surgery. The current medium-term results also show no evidence of a difference in hip function or health-related quality of life in the 5 years following a total hip arthroplasty versus resurfacing arthroplasty. ISRCTN33354155. UKCRN 4093. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use

  16. Comparison of Continuous Femoral Nerve Block with and Without Combined Sciatic Nerve Block after Total Hip Arthroplasty: A Prospective Randomized Study.

    Science.gov (United States)

    Nishio, Shoji; Fukunishi, Shigeo; Fukui, Tomokazu; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Yoshiya, Shinichi

    2017-06-23

    In association with the growing interests in pain management, several modalities to control postoperative pain have been proposed and examined for the efficacy in the recent studies. Various modes of peripheral nerve block have been proposed and the effectiveness and safety have been examined for each of those techniques. We have described our clinical experiences, showing that continuous femoral nerve block could provide a satisfactory analgesic effect after total hip arthroplasty (THA) procedure. In this study, we compared the effectiveness and safety of continuous femoral nerve block with and without sciatic nerve blockade on pain control after THA. Forty patients scheduled for THA were included in the study and randomly divided into 2 groups. Postoperative analgesic measure was continuous femoral nerve block alone, while the identical regimen of continuous femoral nerve block was combined with sciatic nerve block. The amount of postoperative pain was evaluated in the immediate postoperative period, 6 hours, and 12 hours after surgery. Moreover, postoperative complications as well as requirement of supplemental analgesics during the initial 12 hours after surgery were reviewed in the patient record. The obtained study results showed that the supplemental sciatic nerve blockade provided no significant effect on arrival at the postoperative recovery room, while the NRS pain score was significantly reduced by the combined application of sciatic nerve blockade at 6 and 12 hours after surgery. In the investigation of postoperative analgesiarelated complications, no major complication was encountered without significant difference in complication rate between the groups.

  17. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    Science.gov (United States)

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  18. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  19. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  20. OUTCOMES OF PALLIATIVE ORTHOPEDIC SURGERY FOR HIP DISLOCATION IN PATIENTS WITH CEREBRAL PALSY

    OpenAIRE

    R. R. Bidyamshin; S. O. Ryabykh; G. M. Chibirov; D. A. Popkov

    2016-01-01

    Introduction. Hip dislocation is the key problem in patients with severe cerebral palsy (GMFCS IV, V) older than 10 years that affects life quality and limits functional capabilities. In the present study the authors evaluated the efficiency of the proximal femoral resection arthroplasty (pfra) and valgus proximal osteotomy of the femur (VPOF) associated with femoral head resection for pain control, improvement of postural management, hygiene and verticalization with total weight-bearing and ...

  1. Femoral component revision with use of impaction bone-grafting and a cemented polished stem.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2005-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  2. Intraoperative study on anthropometry and gender differences of the proximal tibial plateau at the arthroplasty resection surface.

    Science.gov (United States)

    Yang, Bo; Yu, Jiakuo; Gong, Xi; Chen, Lianxu; Wang, Yongjian; Wang, Jian; Wang, Haijun; Zhang, Jiying

    2014-01-01

    The tibial plateau is asymmetric with a larger medial plateau. We observed from clinical practice that the shape of the tibial plateau does not always present a larger medial plateau. Tibial plateau also showed other shapes. The purpose of this study was to analyze the anthropometric data of the proximal tibia in a large group of Chinese patients undergoing total knee arthroplasty and to investigate the morphology of the resected proximal tibial surface and its gender differences. A total of 822 knees (164 males, 658 females) from the Chinese population were measured intraoperatively for medial anteroposterior (MAP) and lateral anteroposterior (LAP) dimensions of the resected proximal tibial surface. The difference of MAP and LAP (DML) was also calculated as MAP minus LAP. We then classified the data into three groups based on the DML (2 mm) to analyze the morphology of the proximal tibia and its distribution between male and female. The shape of proximal tibial plateau was of three types: larger medial plateau type, symmetric type, and larger lateral plateau type. There were significant differences between males and females in relation to the shape distribution of the proximal tibial plateau (P 2 mm and 120 of 822 (14.6%) tibia having a DMLDMLs to better match the different anthropometry of the resected tibial surface.

  3. CURBSIDE CONSULTATION IN KNEE ARTHROPLASTY: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Craig J. Della Vale

    2008-12-01

    Full Text Available A user- friendly reference for decision making in complicated cases of knee arthroplasty desingned in a question and answers format composed of articles containing current concepts and preferences of experts in total knee replacement surgery, enhanced by several images, diagrams and references and written in the form of a casual advice by Craig J. Della Vale, MD. and his collaborators. PURPOSE By this practical reference of knee arthroplasty, the editor and the contributors have aimed providing straightforward and brief answers, evidence-based advices, their preference and opinions containing current concepts for unanswered questions about complicated cases in total knee replacement surgery which are often controversial and not addressed clearly in traditional knee arthroplasty references. FEATURES There are 49 subjects each written by a different expert designed in 4 sections in a question and answers format including several images and diagrams and also essential references at the end of each article. In the first section preoperative questions is subjected including indications, unicompartmental osteoarthritis of the knee, patient with vascular problems, donating blood, bilateral arthroplasty, patellar resurfacing, range of motion, bearing surface, contraindications, teaching class for patients prior surgery. The second section is about intraoperative questions including skin incision, patella femoral maltracking, femoral component rotation, tibial component rotation, lateral release, femoral component sizing, flexion instability, varus deformity, and valgus deformity, tightness in extension, iatrogenic MCL injury, antibiotic-loaded cement, and perioperative pain. The third section subjects postoperative questions including wound drainage, preventing tromboembolic events, vascular complications, foot drop, manipulation under anesthesia, patella fractures, supracondylar femur fractures, acute extensor mechanism disruptions. In the fourth

  4. What Is the Rerevision Rate After Revising a Hip Resurfacing Arthroplasty? Analysis From the AOANJRR.

    Science.gov (United States)

    Wong, James Min-Leong; Liu, Yen-Liang; Graves, Stephen; de Steiger, Richard

    2015-11-01

    More than 15,000 primary hip resurfacing arthroplasties have been recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) with 884 primary procedures requiring revision for reasons other than infection, a cumulative percent revision rate at 12 years of 11%. However, few studies have reported the survivorship of these revision procedures. (1) What is the cumulative percent rerevision rate for revision procedures for failed hip resurfacings? (2) Is there a difference in rerevision rate among different types of revision or bearing surfaces? The AOANJRR collects data on all primary and revision hip joint arthroplasties performed in Australia and after verification against health department data, checking of unmatched procedures, and subsequent retrieval of unreported procedures is able to obtain an almost complete data set relating to hip arthroplasty in Australia. Revision procedures are linked to the known primary hip arthroplasty. There were 15,360 primary resurfacing hip arthroplasties recorded of which 884 had undergone revision and this was the cohort available to study. The types of revisions were acetabular only, femoral only, or revision of both acetabular and femoral components. With the exception of the acetabular-only revisions, all revisions converted hip resurfacing arthroplasties to conventional (stemmed) total hip arthroplasties (THAs). All initial revisions for infection were excluded. The survivorship of the different types of revisions and that of the different bearing surfaces used were estimated using the Kaplan-Meier method and compared using Cox proportional hazard models. Cumulative percent revision was calculated by determining the complement of the Kaplan-Meier survivorship function at that time multiplied by 100. Of the 884 revisions recorded, 102 underwent further revision, a cumulative percent rerevision at 10 years of 26% (95% confidence interval, 19.6-33.5). There was no difference in the rate of

  5. Total Knee Arthroplasty Designed to Accommodate the Presence or Absence of the Posterior Cruciate Ligament

    Directory of Open Access Journals (Sweden)

    Melinda K. Harman

    2014-01-01

    Full Text Available Evidence for selecting the same total knee arthroplasty prosthesis whether the posterior cruciate ligament (PCL is retained or resected is rarely documented. This study reports prospective midterm clinical, radiographic, and functional outcomes of a fixed-bearing design implanted using two different surgical techniques. The PCL was completely retained in 116 knees and completely resected in 43 knees. For the entire cohort, clinical knee (96±7 and function (92±13 scores and radiographic outcomes were good to excellent for 84% of patients after 5–10 years in vivo. Range of motion averaged 124˚±9˚, with 126 knees exhibiting ≥120° flexion. Small differences in average knee flexion and function scores were noted, with the PCL-resected group exhibiting an average of 5° more flexion but an average function score that was 7 points lower compared to the PCL-retained group. Fluoroscopic analysis of 33 knees revealed stable tibiofemoral translations. This study demonstrates that a TKA articular design with progressive congruency in the lateral compartment can provide for femoral condyle rollback in maximal flexion activities and achieve good clinical and functional performance in patients with PCL-retained and PCL-resected TKA. This TKA design proved suitable for use with either surgical technique, providing surgeons with the choice of maintaining or sacrificing the PCL.

  6. Combination Therapy with Continuous Three-in-One Femoral Nerve Block and Periarticular Multimodal Drug Infiltration after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Tomonori Tetsunaga

    2016-01-01

    Full Text Available Background. Various postoperative pain relief modalities, including continuous femoral nerve block (CFNB, local infiltration analgesia (LIA, and combination therapy, have been reported for total knee arthroplasty. However, no studies have compared CFNB with LIA for total hip arthroplasty (THA. The aim of this study was to compare the efficacy of CFNB versus LIA after THA. Methods. We retrospectively reviewed the postoperative outcomes of 93 THA patients (20 men, 73 women; mean age 69.2 years. Patients were divided into three groups according to postoperative analgesic technique: CFNB, LIA, or combined CFNB+LIA. We measured the following postoperative outcome parameters: visual analog scale (VAS for pain at rest, supplemental analgesia, side effects, mobilization, length of hospital stay, and Harris Hip Score (HHS. Results. The CFNB+LIA group had significantly lower VAS pain scores than the CFNB and LIA groups on postoperative day 1. There were no significant differences among the three groups in use of supplemental analgesia, side effects, mobilization, length of hospital stay, or HHS at 3 months after THA. Conclusions. Although there were no clinically significant differences in outcomes among the three groups, combination therapy with CFNB and LIA provided better pain relief after THA than CFNB or LIA alone, with few side effects.

  7. Cement augmentation in the proximal femur to prevent stem subsidence in revision hip arthroplasty with Paprosky type II/IIIa defects

    Directory of Open Access Journals (Sweden)

    Shang-Wen Tsai

    2018-06-01

    Full Text Available Background: Subsidence remains a common complication after revision hip arthroplasty which may lead to prolonged weight-bearing restrictions, leg-length discrepancies or considerable loss of function. We evaluated the effectiveness of cement augmentation in the proximal femoral metaphysis during a revision of femoral components to prevent post-operative stem subsidence. Methods: Forty patients were enrolled. Follow-up averaged 67.7 months (range: 24–149. Twenty-seven patients had a Paprosky type II defect and 13 had a type IIIa defect. All revision hip arthroplasty used a cementless, cylindrical, non-modular cobalt–chromium stem. The defect in the metaphysis was filled with antibiotic-loaded bone cement. Thirteen patients who had undergone stem revision only was allowed to walk immediately without weight-bearing restrictions. Twenty-seven patients who had undergone revision total hip arthroplasty was allowed partial weight-bearing within 6 weeks after surgery in the consideration of acetabular reconstruction. Results: Three patients (7.5% had post-surgery stem subsidences of three mm, five mm, and 10 mm, respectively, at three, one, and 14 months. There were no acute surgical site infections. There were three femoral stem failures: two delayed infections and one periprosthetic Vancouver B2 fracture. Both five- and 10-year survivorships of the femoral implant were 90.1%. Conclusion: An adequate length of the scratch-fit segment and diaphyseal ingrowth remain of paramount importance when revising femoral components. To fill metaphyseal bone defects with antibiotic-loaded bone cement may be an alternative method in dealing with proximal femoral bone loss during a femoral revision. Keywords: Bone defect, Cement augmentation, Femur, Revision hip arthroplasty, Subsidence

  8. Selective peripheral nerve resection for treatment of persistent pain around the knee joint after total knee arthroplasty.

    Science.gov (United States)

    Zhong, Guangjun; Liang, Zhu; Kan, Jiang; Muheremu, Aikeremujiang

    2018-01-01

    Objective This study was performed to determine the efficacy of selective peripheral nerve resection for treatment of persistent neuropathic pain after total knee arthroplasty (TKA). Methods Patients who underwent TKA in our department from January 2013 to July 2016 and experienced persistent pain around the knee joint after TKA were retrospectively included in the current study. Sixty patients were divided into experimental and control groups according the treatment they received. The treatment effect was evaluated by the Hospital for Special Surgery (HSS) knee score and visual analog scale (VAS) pain score preoperatively and at 1, 2, 3, 6, and 12 months postoperatively. Results The HSS knee scores were higher in both groups after than before the treatment, and HSS knee scores were significantly higher in the experimental group than in the control group. The VAS pain scores were lower in both groups after than before the treatment, and VAS pain scores were significantly lower in the experimental group than in the control group. Conclusions Selective peripheral nerve resection is an effective treatment method for persistent neuropathic pain after TKA.

  9. Femoral component revision with use of impaction bone-grafting and a cemented polished stem. Surgical technique.

    NARCIS (Netherlands)

    Schreurs, B.W.; Arts, J.J.C.; Verdonschot, N.J.J.; Buma, P.; Slooff, T.J.J.H.; Gardeniers, J.W.M.

    2006-01-01

    BACKGROUND: The purpose of this study was to evaluate the clinical and radiographic outcomes of revision of the femoral component of a hip arthroplasty with use of an impaction bone-grafting technique and a cemented polished stem. METHODS: Thirty-three consecutive femoral reconstructions that were

  10. The importance of bony impingement in restricting flexion after total knee arthroplasty: computer simulation model with clinical correlation.

    Science.gov (United States)

    Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D

    2012-10-01

    We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with 125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahmoud Jabalameli

    2016-04-01

    Full Text Available Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. Methods: One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. Results: The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Conclusion: Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be

  12. Factors affecting femoral rotational angle based on the posterior condylar axis in gap-based navigation-assisted total knee arthroplasty for valgus knee.

    Science.gov (United States)

    Lee, Sung-Sahn; Lee, Yong-In; Kim, Dong-Uk; Lee, Dae-Hee; Moon, Young-Wan

    2018-01-01

    Achieving proper rotational alignment of the femoral component in total knee arthroplasty (TKA) for valgus knee is challenging because of lateral condylar hypoplasia and lateral cartilage erosion. Gap-based navigation-assisted TKA enables surgeons to determine the angle of femoral component rotation (FCR) based on the posterior condylar axis. This study evaluated the possible factors that affect the rotational alignment of the femoral component based on the posterior condylar axis. Between 2008 and 2016, 28 knees were enrolled. The dependent variable for this study was FCR based on the posterior condylar axis, which was obtained from the navigation system archives. Multiple regression analysis was conducted to identify factors that might predict FCR, including body mass index (BMI), Kellgren-Lawrence grade (K-L grade), lateral distal femoral angles obtained from the navigation system and radiographs (NaviLDFA, XrayLDFA), hip-knee-ankle (HKA) axis, lateral gap under varus stress (LGVS), medial gap under valgus stress (MGVS), and side-to-side difference (STSD, MGVS - LGVS). The mean FCR was 6.1° ± 2.0°. Of all the potentially predictive factors evaluated in this study, only NaviLDFA (β = -0.668) and XrayLDFA (β = -0.714) predicted significantly FCR. The LDFAs, as determined using radiographs and the navigation system, were both predictive of the rotational alignment of the femoral component based on the posterior condylar axis in gap-based TKA for valgus knee. A 1° increment with NaviLDFA led to a 0.668° decrement in FCR, and a 1° increment with XrayLDFA led to a 0.714° decrement. This suggests that symmetrical lateral condylar hypoplasia of the posterior and distal side occurs in lateral compartment end-stage osteoarthritis with valgus deformity.

  13. Periprosthetic femoral fracture within two years after total hip replacement:

    DEFF Research Database (Denmark)

    Thien, T. M.; Chatziagorou, G.; Garellick, G.

    2014-01-01

    BACKGROUND: We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacement....... METHODS: Included in the study were 325,730 cemented femoral stems and 111,899 uncemented femoral stems inserted from 1995 to 2009. Seven frequently used stems (two cemented stems [Exeter and Lubinus SP II] and five uncemented stems [Bi-Metric, Corail, CLS Spotorno, ABG I, and ABG II]) were specifically...... studied. RESULTS: The incidence of revision at two years was low: 0.47% for uncemented stems and 0.07% for cemented stems. Uncemented stems were much more likely to have this complication (relative risk, 8.72 [95% confidence interval, 7.37 to 10.32]; p

  14. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    Science.gov (United States)

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  15. Femoral nerve block using ropivacaine 0.025%, 0.05% and 0.1%: effects on the rehabilitation programme following total knee arthroplasty: a pilot study.

    Science.gov (United States)

    Paauwe, J J; Thomassen, B J; Weterings, J; van Rossum, E; Ausems, M E

    2008-09-01

    Femoral nerve blockade is recommended for analgesia following total knee arthroplasty. Following implementation of this type of postoperative analgesia in our hospital we found that active mobilization the day after surgery, may be difficult due to insufficient quadriceps muscle strength. We therefore designed a pilot study comparing the effect of ropivacaine 0.1%, 0.05% or 0.025% on the patient's postoperative rehabilitation and analgesia. Three groups of 12 patients received bolus doses of ropivacaine via their femoral nerve catheters for postoperative analgesia. The ability to actively mobilize, quadriceps muscle strength, pain VAS-scores and patient's satisfaction were measured during in the first three postoperative days. There were no significant differences in the patient's ability to actively mobilize and the pain VAS-scores. The overall satisfaction of the patients with the pain treatment was significantly better (p = 0.049) in the 0.1% compared with the 0.025% group. This pilot-study demonstrated no advantage associated with the use of a ropivacaine concentration less than 0.1%.

  16. Endotoxins in surgical instruments of hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vania Regina Goveia

    2016-06-01

    Full Text Available Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested.

  17. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  18. Subchondral insufficiency fractures of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M.; Cassar-Pullicino, V.N. [Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom); Darby, A.J. [Department of Pathology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom)

    2004-02-01

    The aim of this study was to increase awareness of, and to show the variable clinical and radiological features of, subchondral insufficiency fractures of the femoral head. The clinical and radiological findings in 7 patients with subchondral insufficiency fractures of the femoral head were reviewed retrospectively. The diagnosis was confirmed histologically in 4 patients. Radiographs were performed in all patients, MRI in 5 and scintigraphy in 4 patients. Radiographs showed varying degrees of femoral head collapse in 4 patients. In the remaining 3 patients radiographs showed a normal femoral head, regional osteoporosis and focal sclerosis, respectively. Magnetic resonance imaging showed a low-signal band on T1- and T2-weighted images in the subchondral bone adjacent or parallel to the articular surface associated with bone marrow oedema. Scintigraphy showed increased uptake in the femoral head. Insufficiency fractures of the femoral head are easily overlooked or confused with avascular necrosis and, when there is significant joint destruction, osteoarthritis. Unsuspected insufficiency fracture of the femoral head can lead to significant and rapid loss of bone stock in osteoporotic patients waiting for arthroplasty for osteoarthritis. Increased awareness of this condition will hopefully lead to earlier diagnosis and a successful outcome of conservative treatment. (orig.)

  19. Failure of aseptic revision total knee arthroplasties.

    Science.gov (United States)

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-02-01

    In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties.

  20. Avascular necrosis of the femoral head at 2 years after pertrochanteric fracture surgery: Case report.

    Science.gov (United States)

    Deleanu, Bogdan; Prejbeanu, Radu; Vermesan, Dinu; Honcea, Lucian; Mioc, Mihail Lazar; Tsiridis, Eleftherios; Predescu, Vlad

    2016-02-01

    The avascular necrosis of the femoral head represents the death of bone tissue due to the lack of blood supply. The disease has a progressive evolution and left untreated leads to femoral head collapse and severe arthritis. We present a case of a pertrochanteric fracture which has been successfully operated with a dynamic interlocking trochanteric gamma nail on the right hip. At 2 years after surgery the patient developed an incipient avascular necrosis of the femoral head. Despite the good positioning of the implant, we considered that the source of the pain was an intolerance of the implant, and thus we removed it. After implant removal, the patient was kept under observation and conservative treatment, to prevent further damage to the right hip and allow the healing to occur. At 6 months after the gamma nail was removed the X-rays revealed advanced avascular necrosis of the femoral head and secondary osteoarthritis on the right hip. The patient underwent surgery with an uncemented total hip arthroplasty. There are a few discussions regarding the avascular necrosis of the femoral head. These discussions may include the predisposing risk factors, the treatment of choice and the postoperative complications. The avascular necrosis of the femoral head is a complication of pertrochanteric fractures that can not be foreseen or avoided. The optimal treatment in these cases is uncemented total hip arthroplasty.

  1. Adaptive Bone Remodeling of the Femoral Bone After Tumor Resection Arthroplasty With an Uncemented Proximally Hydroxyapatite-Coated Stem

    DEFF Research Database (Denmark)

    Andersen, Mikkel R.; Petersen, Michael M.

    2016-01-01

    -fluted 125-mm uncemented press-fit titanium alloy stem with hydroxyapatite coating of the proximal part of the stem. Measurements of bone mineral density (BMD; g/cm2) were done postoperatively and after 3, 6, and 12 mo in the part of the femur bone containing the Global Modular Replacement System stem using...... of 8%-9% during the first postoperative year was seen along the femoral stem, but in the bone containing the hydroxyapatite-coated part of the stem, the decrease in BMD was 14%, thus indicating that stress shielding of this part of the bone may play a role for the adaptive bone remodeling....

  2. No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

    Science.gov (United States)

    Minoda, Yukihide; Hata, Kanako; Iwaki, Hiroyoshi; Ikebuchi, Mitsuhiko; Hashimoto, Yusuke; Inori, Fumiaki; Nakamura, Hiroaki

    2014-03-01

    Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 μm in the case of oxidized zirconium and 0.6 ± 0.1 μm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. Therapeutic study, Level III.

  3. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  4. Treatment of neglected femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Anil K Jain

    2015-01-01

    Full Text Available Intra-capsular femoral neck fractures are seen commonly in elderly people following a low energy trauma. Femoral neck fracture has a devastating effect on the blood supply of the femoral head, which is directly proportional to the severity of trauma and displacement of the fracture. Various authors have described a wide array of options for treatment of neglected/nonunion (NU femoral neck fracture. There is lack of consensus in general, regarding the best option. This Instructional course article is an analysis of available treatment options used for neglected femoral neck fracture in the literature and attempt to suggest treatment guides for neglected femoral neck fracture. We conducted the "Pubmed" search with the keywords "NU femoral neck fracture and/or neglected femoral neck fracture, muscle-pedicle bone graft in femoral neck fracture, fibular graft in femoral neck fracture and valgus osteotomy in femoral neck fracture." A total of 203 print articles were obtained as the search result. Thirty three articles were included in the analysis and were categorized into four subgroups based on treatment options. (a treated by muscle-pedicle bone grafting (MPBG, (b closed/open reduction internal fixation and fibular grafting (c open reduction and internal fixation with valgus osteotomy, (d miscellaneous procedures. The data was pooled from all groups for mean neglect, the type of study (prospective or retrospective, classification used, procedure performed, mean followup available, outcome, complications, and reoperation if any. The outcome of neglected femoral neck fracture depends on the duration of neglect, as the changes occurring in the fracture area and fracture fragments decides the need and type of biological stimulus required for fracture union. In stage I and stage II (Sandhu′s staging neglected femoral neck fracture osteosynthesis with open reduction and bone grafting with MPBG or Valgus Osteotomy achieves fracture union in almost 90

  5. Avascular necrosis of the femoral head at 2 years after pertrochanteric fracture surgery: Case report

    Directory of Open Access Journals (Sweden)

    Bogdan Deleanu

    2016-02-01

    Conclusion: The avascular necrosis of the femoral head is a complication of pertrochanteric fractures that can not be foreseen or avoided. The optimal treatment in these cases is uncemented total hip arthroplasty.

  6. Accuracy Veriffication of Image-Matching in a Setting Method for the Stem during Total Hip Arthroplasty

    OpenAIRE

    Kubota, Yosuke; Sakamoto, Makoto; Kobayashi, Koichi; Koga, Yoshio; Tanabe, Yuji

    2010-01-01

    Currently, stem insertion during total hip arthroplasty (THA) is not well controlled. The present study investigated a method for improving stem setting in accordance with preoperative planning using a three-dimensional (3-D) computed tomography (CT) model of the femur and RGB images of the excised femoral head. We utilized three femoral heads removed during THA and modeled each head using three spherical acrylic markers. Each femoral head was osteotomized using a parallel jig and three recta...

  7. [Non-cemented self-locking total arthroplasty of the hip. Clinical and radiological results after three years].

    Science.gov (United States)

    Desjardins, A L; Roy, A; Duchesne, R; Béliveau, P; Fallaha, M; Bornais, S

    1993-01-01

    We reviewed 47 patients who had fifty-one (51) primary, cementless biofit total hip arthroplasties (THA) implanted at Maisonneuve-Rosemont Hospital between 1986 and 1990. An independent observer rated the patients on the Harris Hip Score (HHS) by questionnaire, physical examination and radiological assessment. The average follow-up was 40 months. Twenty-two percent (22%) of the femoral components had been revised because of incapacitating pain, limping or a HHS inferior to 60. A little more than 20% of the unrevised prostheses had a mediocre result (HHS inferior to 70). There was no correlation between results and radiological signs of instability. The femoral component of the hip arthroplasty has a poor clinical performance which compares unfavourably with cemented prostheses.

  8. Total hip arthroplasty for femoral neck fractures as an urgent procedure

    Directory of Open Access Journals (Sweden)

    Radoičić Dragan

    2017-01-01

    Full Text Available Background/Aim. Total hip arthroplasty (THA is one of the most widely accepted operative methods for femoral neck fracture (FNF in elderly. However, the data on the early THA for FNF are very limited. The aim of this study to determine if there were differences in postoperative complications and functional outcomes between an urgent and delayed THA following FNF. Methods. This prospective study included a total of 244 patients who had THA following FNF from January 2010 to January 2013. In the first group 41 FNF patients were treated with THA within less than 12 hours of admission. A total of 203 FNF patients were operated in delayed settings, of whom 162 required prolonged preoperative processing and comorbidities correction. The group II consisted of 41 FNF patients who were fit for the early surgery at admission, but the operation was delayed due to institution related reasons. Main outcome measurements included mortality, functional outcome assessement, cardiological and pulmonary complications, pressure ulcers, dislocations, infections, length of hospitalization and revisions. Results. There were no differences in terms of age, gender, type of implants, neither in mortality, nor complications. There were differences in hospital length of stay [t (51.72 = -10.25, p < 0.001]. The patients operated within less than 12 hours of admission, had significantly better scores at all three time points of functional outcome assessment: at discharge t (80 = 2.556, p < 0.012; one month t (80 = 4.731, p < 0.001; three months t (80 = 5.908, p < 0.001. Conclusion. THA for FNF as an urgent procedure is not a widely accepted concept. Our findings indicate that the early operative treatment, does not worsen clinical outcomes, and our results give an advantage to the policy of the early THA for FNF.

  9. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    Science.gov (United States)

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  10. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  11. A multi-modality tracking, navigation and calibration for a flexible robotic drill system for total hip arthroplasty.

    Science.gov (United States)

    Ahmad Fuad, Ahmad Nazmi Bin; Deep, Kamal; Yao, Wei

    2018-02-01

    This paper presents a novel multi-modality tracking and navigation system that provides a unique capability to guild a flexible drill tip inside the bone with accurate curved tunnelling. As the flexible drill tip cannot be tracked optically inside the bone, this research focuses on developing a hybrid tracking and navigation system for tracking a flexible drill tip by using both optical and kinematic tracking. The tracking information is used to guide the THA (total hip arthroplasty) procedure, providing a real-time virtual model of the flexible drill. The flexible and steerable drill tip system is then tested on total hip arthroplasty followed by evaluation of the positioning and orientation of femoral stem placement by femoral milling. Based on this study, we conclude that the tracking and navigation system is able to guide the flexible drill to mill inside femoral canal. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Femoral head vitality after intracapsular hip fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.

    1983-01-01

    Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or 99 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the hook-pin group. This was also clearly demonstrated in a one-year follow-up for the fractures included in the study. Parallel to these investigations, the reliability of the methods of vitality determination was found satisfactory in methodologic studies. For clinical purpose, primary atraumatic osteosynthesis, postoperative prognostic scintimetry and early secondary arthroplasty when indicated, was concluded to be the appropriate approach to femoral neck fracture treatment. (Author)

  13. Bilateral avascular necrosis of the femoral head due to the use of heroin: A case report.

    Science.gov (United States)

    Ozkunt, Okan; Sarıyılmaz, Kerim; Sungur, Mustafa; Ilen, Ferhat; Dikici, Fatih

    2015-01-01

    Femoral head avascular necrosis is caused by disruption of the blood supply of the femoral head, which finally results in hip dysfunction. Non traumatic osteonecrosis may related with corticosteroid use, alcohol abuse, SLE, hemoglobinopathies or exposure to cytotoxic agents. But avascular necrosis of the femoral head (ANFH) due to heroin use is a rare condition. We report a patient with bilateral ANFH due to heroin use treated by simultaneous bilateral hip arthroplasty. 37 year-old male patient presented with bilateral hip pain that had been occurring for four years. The patient had no history of smoking, excessive drinking, using corticosteroid and the other drugs or trauma but used heroin for 10 years. In clinic and radiologic examination indicated advanced degenerative changes on both hip due to femoral head avascular necrosis. The patient was treated with simultaneous bilateral total hip arthroplasty. After 6 months postoperatively the active hip range of motion was painless. Avascular femoral head necrosis caused by the using of heroin is rare. Ultimately, osteonecrosis of the femoral head occurs through one final common pathway, which is decreased blood flow to the femoral head that leads bone ischemia and death. But it is still unknown that heroin's systemic effects. Intravenous drug use more as a serious problem for today. There is a need for comprehensive studies to demonstrate effects of heroin on bone and vascularity metabolism. Heroin use will be important problem for population. That's why is crucial to understand the effect of heroin. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Increased risk of intraoperative and early postoperative periprosthetic femoral fracture with uncemented stems

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer C.; Solgaard, Søren

    2017-01-01

    Background and purpose - The use of uncemented fixation in total hip arthroplasty (THA) is increasing. Registry studies have indicated an increased risk of revision of uncemented implants due to early periprosthetic femoral fracture. In this paper, we describe the incidence and predisposing facto...

  15. A-Frame free Vascularized Fibular Graft and Femoral Lengthening for Osteosarcoma Pediatric Patients.

    Science.gov (United States)

    Cashin, Megan; Coombs, Christopher; Torode, Ian

    2018-02-01

    Pediatric limb reconstruction after resection of a malignant tumor presents specific challenges. Multiple surgical techniques have been used to treat these patients. This paper describes a staged surgical technique for the reconstruction of large distal femoral defects due to tumor resection in skeletally immature patients. Three pediatric patients with osteosarcoma of the distal femur underwent staged reconstruction. Neoadjuvant chemotherapy was followed by en bloc tumor resection and immediate reconstruction of the distal femoral defect with a vascularized free fibular autograft utilizing a unique A-frame construct combined with intramedullary nail fixation. The second stage was a planned gradual lengthening of the healed construct, over a custom-made magnetically driven expandable intramedullary nail. All patients achieved bony union and satisfactory length with minimal complications. The patients all returned to full, unlimited physical activities. The early results confirm that the described technique is a safe and reliable procedure for the reconstruction of large femoral defects in pediatric patients with osteosarcoma. Level IV-therapeutic.

  16. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    Science.gov (United States)

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  17. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    Science.gov (United States)

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and

  18. Comparison of total hip arthroplasty in osteoarthritis of mechanical and rheumatologic causes

    Science.gov (United States)

    Ejnisman, Leandro; Leonhardt, Nathalia Zalc; Fernandes, Laura Fillipini Lorimier; Leonhardt, Marcos de Camargo; Vicente, José Ricardo Negreiros; Croci, Alberto Tesconi

    2014-01-01

    Objective: To compare the use of uncemented implants in total hip arthroplasty in patients with rheumathologic diseases and mechanical osteoarthrosis. Methods: We retrospectively evaluated 196 patients who were operated by the Hip and Arthroplasty Surgery Group of the IOT-HCFMUSP between 2005 and 2009. Patients were divided into two groups: mechanical causes (165 patients) and rheumathologic causes (31 patients). Groups were compared between each other in age, gender and follow-up time. Osseointegration rate and percentage of failure in arthroplasty were evaluated. Results: No statistically significant difference was found in osseointegration rates (in both femoral and acetabular components) in both groups. The rates of revision surgery and implant survival also did not show statistically significant differences. Conclusion: The use of uncemented total hip arthroplasty did not show worse results in rheumathologic patients. Level of Evidence III, Retrospective Case Control Study. PMID:24644419

  19. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty. Precision biased by region of interest and rotation of the hip

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

      Introduction:  Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type of ROI...... the hip was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without...

  20. Dynamics of biochemical and immunological blood markers in patients with pseudoarthrosis of the femoral neck after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    S. E. Bondarenko

    2017-08-01

    Full Text Available The importance of biomarkers to predict recovery following total hip arthroplasty (THA is still unclear to clinicians. To assess the preoperative biomarkers of patients with pseudoarthrosis of the femoral neck and their dynamics in the early postoperative period after THA, 50 patients aged 33 to 82 years old, 18 males and 32 females diagnosed with pseudoarthrosis of the femoral neck after failed internal fixation and failed conservative management were studied. The control group consisted of 30 healthy people aged 27 to 50 years, 13 males, 17 females. Patients’ blood was examined for biochemical markers upon admission, and then on the 7th and 14th days after surgery. Their blood serum content of total protein, albumin, glycoproteins, sialic acids, chondroitin sulfates, haptoglobin, glucose, cholesterol, triglycerides, ALT, AST, alkaline phosphatase, GGT, acid phosphatase, thymol index; interleukins (IL-1, IL-4 and IL-6. and C-reactive protein was measured. The content of glycoproteins in the blood exceeded the norm by 2.3 times, chondroitin sulfate by 4.7 times, sialic acids by 1.5 times, haptoglobin by 55.8%, fibrinogen by 19.1%, globulin by 19,6%, alkaline phosphatase activity by 72.3%, IL-1 by 94.7 and IL-6 by 3 times, C-reactive protein by 2.6 times. After THA there was a gradual decrease in blood biochemical and immunological markers. The most informative laboratory markers were glycoproteins, chondroitin sulfates, sialic acids, haptoglobin, activity of alkaline phosphatase, IL-1, IL-6 and IL-4, and C-reactive protein. Subsequent research is required to validate these dynamics.

  1. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  2. Increases in tibial force imbalance but not changes in tibiofemoral laxities are caused by varus-valgus malalignment of the femoral component in kinematically aligned TKA.

    Science.gov (United States)

    Riley, Jeremy; Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-01-29

    The purposes of this study were to quantify the increase in tibial force imbalance (i.e. magnitude of difference between medial and lateral tibial forces) and changes in laxities caused by 2° and 4° of varus-valgus (V-V) malalignment of the femoral component in kinematically aligned total knee arthroplasty (TKA) and use the results to detemine sensitivities to errors in making the distal femoral resections. Because V-V malalignment would introduce the greatest changes in the alignment of the articular surfaces at 0° flexion, the hypotheses were that the greatest increases in tibial force imbalance would occur at 0° flexion, that primarily V-V laxity would significantly change at this flexion angle, and that the tibial force imbalance would increase and laxities would change in proportion to the degree of V-V malalignment. Kinematically aligned TKA was performed on ten human cadaveric knee specimens using disposable manual instruments without soft tissue release. One 3D-printed reference femoral component, with unmodified geometry, was aligned to restore the native distal and posterior femoral joint lines. Four 3D-printed femoral components, with modified geometry, introduced V-V malalignments of 2° and 4° from the reference component. Medial and lateral tibial forces were measured during passive knee flexion-extension between 0° to 120° using a custom tibial force sensor. Eight laxities were measured from 0° to 120° flexion using a six degree-of-freedom load application system. With the tibial component kinematically aligned, the increase in the tibial force imbalance from that of the reference component at 0° of flexion was sensitive to the degree of V-V malalignment of the femoral component. Sensitivities were 54 N/deg (medial tibial force increasing > lateral tibial force) (p  medial tibial force) (p imbalance to increase significantly, whereas the laxities were relatively unaffected. Because tibial force imbalance has the potential to

  3. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial

    DEFF Research Database (Denmark)

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup...... arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured...... approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; pcup anteversion but less...

  4. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    Science.gov (United States)

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  5. Tranexamic Acid Safely Reduced Blood Loss in Hemi- and Total Hip Arthroplasty for Acute Femoral Neck Fracture: A Randomized Clinical Trial.

    Science.gov (United States)

    Watts, Chad D; Houdek, Matthew T; Sems, S Andrew; Cross, William W; Pagnano, Mark W

    2017-07-01

    We aimed to determine whether (1) tranexamic acid (TXA) reduces the incidence of transfusion (2) TXA reduces the calculated blood loss, and (3) there are any observable differences in 30- and 90-day complications with TXA administration during arthroplasty for femoral neck fracture (FNF). Prospective, double-blinded, randomized controlled trial. Level 1 Academic Trauma Center. One hundred thirty-eight patients who presented with a low-energy, isolated, FNF (AO 31B) treated with either hemi- or total hip arthroplasty within 72 hours of injury were randomized to either the TXA group (69 patients) or placebo group (69 patients). In the TXA group, patients received 2 doses of 15 mg/kg intravenous TXA dissolved in 100 mL of saline, each administered over 10 minutes; 1 dose just before incision, and the second at wound closure. In the placebo group, 100 mL of saline solution was administered in a similar fashion. Perioperative care was otherwise standardized including conservative transfusion criteria. Our primary outcome was to determine the proportion of patients who underwent blood transfusion during hospitalization. Secondary outcomes were calculated blood loss, number of units transfused during hospitalization, and incidence of adverse events at 30 and 90 days including thromboembolic event, wound complications, reoperation, hospital readmission, and all-cause mortality. TXA reduced mean incidence of transfusion by 305 mL (P = 0.0005). There was a trend toward decreased transfusion rate in the TXA group (17% vs. 26%, P = 0.22). TXA was safe with no differences in adverse events at 30 and 90 days. This randomized clinical trial found that TXA administration safely reduced blood loss with a tendency for decreased transfusion rate and total blood product consumption for patients undergoing hip arthroplasty for acute FNF. More studies are needed to further ascertain the role of TXA in the management of patients with FNF. Therapeutic Level I. See Instructions for Authors

  6. Stem cell treatment for avascular necrosis of the femoral head: current perspectives

    Directory of Open Access Journals (Sweden)

    Houdek MT

    2014-04-01

    Full Text Available Matthew T Houdek,1 Cody C Wyles,2 John R Martin,1 Rafael J Sierra11Department of Orthopedic Surgery, 2School of Medicine, Mayo Clinic, Rochester, MN, USAAbstract: Avascular necrosis (AVN of the femoral head is a progressive disease that predominantly affects younger patients. Although the exact pathophysiology of AVN has yet to be elucidated, the disease is characterized by a vascular insult to the blood supply of the femoral head, which can lead to collapse of the femoral head and subsequent degenerative changes. If AVN is diagnosed in the early stages of the disease, it may be possible to attempt surgical procedures which preserve the hip joint, including decompression of the femoral head augmented with concentrated bone marrow. The use of autologous stem cells has shown promise in halting the progression of AVN of the femoral head, and subsequently preventing young patients from undergoing total hip arthroplasty. The purpose of this study was to review the current use of stem cells for the treatment of AVN of the femoral head.Keywords: avascular necrosis, femoral head, osteonecrosis, stem cells, concentrated bone marrow

  7. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    Science.gov (United States)

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  8. Autologous Platelet Concentrates as Treatment for Avascular Necrosis of Femoral Head in a Dog.

    Science.gov (United States)

    Parra, Estefanía; Vergara, Andrea; Silva, Raúl F

    2017-03-01

    Avascular necrosis of the femoral head is a developmental disturbance that generally affects young dogs of small breeds and produces ischemic necrosis of the femoral head resulting in an incongruous and malformed joint. The most common treatment is the excisional arthroplasty of the head and femoral neck. The aim of this study is to describe the treatment of avascular necrosis in a Yorkshire dog using intra-articular injections of autologous platelet concentrate. Evaluations were made at 0, 15, 30, 60, and 120 days of treatment, describing the following parameters: clinical gait analysis, perimetry, goniometry, and radiographic evaluations. The results obtained in this case suggest that the autologous platelet concentrate may be an alternative for the treatment of avascular necrosis of the femoral head in dogs. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial.

    Science.gov (United States)

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; pcup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.

  10. Cost-effectiveness of positive contrast and nuclear arthrography in patients who underwent total hip arthroplasty

    International Nuclear Information System (INIS)

    Swan, J.S.; Braunstein, E.M.; Capello, W.; Wellman, H.

    1989-01-01

    The authors have compared the cost effectiveness of contrast arthrography (CA) and nuclear arthrography (NA), in which In-111 chloride is injected with the contrast material, of total hip arthroplasties. Their series included 48 cases of surgically proved loose femoral components. The cost per true-positive result was obtained by taking the total cost of the examinations in surgically proved cases and dividing by the number of true-position cases. The cost of CA was $297 and the cost of NA was $335. For CA, the cost per true positive was $1,018, and for the NA the cost per true positive was $946. In spite of higher initial cost, NA is more cost effective than CA on a cost per true-positive case basis. NA is cost effective in evaluating hip arthroplasties in which there is suspicion of a loose femoral component

  11. Femoral neck pseudoarthrosis in a polio patient treated with closed reduction and cell therapy

    Directory of Open Access Journals (Sweden)

    M.A. Codesido

    2017-04-01

    Full Text Available Poliomyelitis disease affects the anterior horns cells of the spinal cord and certain motor nuclei of the brain stem. Paralysis type is flaccid and asymmetrical and result in muscular imbalance.Due to this, in case of having a hip muscles involvement, degenerative or posttraumatic, total hip arthroplasty is normally contraindicated because of the excessive risk of hip dislocation. In cases of subcapital femoral neck fractures the femoral head vascularization is a main concern, and in cases of neglected fracture with pseudoarthrosis the vascular status to the head must be investigated prior to further decisions.We report the case of a femoral neck fracture non-union after a missed femoral neck fracture in a polio affected leg treated with cannulated screws and percutaneous autologous injection of processed total nuclear cells (TNC mixed with putty demineralized bone matrix. Keywords: Pseudoarthrosis, Poliomyelitis, Cell therapy, Femoral neck

  12. Arthrography of painful hips following arthroplasty: Digital versus plain film subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, C W; FitzRandolph, R L; Dalrymple, G V [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Radiology John McClellan Memorial Veterans Hospital, Little Rock, AR (USA); Collins, D N [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Orthopedics John McClellan Memorial Veterans Hospital, Little Rock, AR (USA)

    1991-08-01

    Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P < 0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses. (orig./GDG).

  13. ACL status in arthroplasty patients, why not to preserve?

    Directory of Open Access Journals (Sweden)

    Abdelbadie Ahmed

    2018-01-01

    Full Text Available Introduction: Only 70–85% of patients that had total knee arthroplasty (TKA are satisfied with their knees. The need for a near to normal knee kinematics is crucial and maybe the solution to their needs. Addressing the cruciate ligaments during surgery along with the extent of arthrosis may give a solution to this problem. Material and methods: One hundred consecutive patients in whom a total knee arthroplasty was indicated and performed were prospectively documented. During the knee replacement surgery, the condition of the anterior and posterior cruciate ligaments and the degree of osteoarthritis (OA in the medial and lateral compartments as well as in the patello-femoral joint were documented using the Outerbridge classification. The patients’ average age was 72.3 years, with the majority being female. In all patients, a total bi-compartmental knee replacement was indicated. Results: Our results showed that in 78% of all patients the anterior, and in 98% the posterior cruciate ligament was still intact. Seventy-one percent of cases suffered from grade 4 medial osteoarthritis, 19% from grade 3 and 10% from grade 2. Thirty-six of patients suffered from grade 4 lateral osteoarthritis, 36% from grade 3, 24% from grade 2 and 4% from grade 1. Grade 4 patello-femoral osteoarthritis was present in 32% of all patients, grade 3 in 60% and grade 2 in 8% of all patients. Discussion: The goal of arthroplasty is to approximate the function of a normal knee. The retention of the anterior cruciate ligament (ACL allows for better knee, kinematics, improved proprioception, increased flexion and an overall improvement in knee function. The decreased constraint that is possible with retention of both cruciates may decrease implant stresses and improve the implant survivorship. The distribution of OA shows that the medial and patello-femoral compartments of the joint are primarily affected. This could also allow for a more conservative and patient

  14. Can Arthroplasty Stem INfluence Outcome? (CASINO): a randomized controlled equivalence trial of 125 mm versus 150 mm Exeter V40 stems in total hip arthroplasty.

    Science.gov (United States)

    Hamilton, David F; Ohly, Nicholas E; Gaston, Paul

    2018-04-16

    The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.

  15. A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Directory of Open Access Journals (Sweden)

    Clijmans Tim

    2010-07-01

    Full Text Available Abstract Background Hip surface replacement arthroplasty (SRA can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS. Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre. Methods A custom made neck jig device is presented as well as the results of a pilot study. The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned. Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation. Results The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife

  16. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    Science.gov (United States)

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  17. Pigmented Villonodular Synovitis Causing Osteonecrosis of the Femoral Head: A Case Report

    Directory of Open Access Journals (Sweden)

    Tomohiro Mimura

    2013-01-01

    Full Text Available We report a case of a 27-year-old man with pigmented villonodular synovitis of the hip joint with coincident osteonecrosis of the femoral head. According to our review of the English-language literature, no detailed report of osteonecrosis of the femoral head complicated with pigmented villonodular synovitis has been published. Preoperative X-ray images showed joint narrowing and severe multiple bone erosions at the acetabulum and femoral neck. Magnetic resonance imaging revealed a low-intensity band attributable to osteonecrosis of the femoral head and massive diffuse pigmented villonodular synovitis lesions. Comparison of a three-dimensional computed tomographic image of this patient with an angiographic image of a normal individual demonstrated proximity of the pigmented villonodular synovitis-induced bone erosions to the medial and lateral femoral circumflex arteries and retinacular arteries, suggesting likely the compromise of the latter by the former. We propose that the massive pigmented villonodular synovitis may have contributed to the pathogenesis of osteonecrosis of the femoral head in this patient. We performed open synovectomy and total hip arthroplasty. No operative complications occurred, and no recurrence of the pigmented villonodular synovitis was detected for 3 years after the operation.

  18. "Tripolar" hip arthroplasty for failed hip resurfacing: nineteen years follow-up.

    Science.gov (United States)

    Scheerlinck, T; Casteleyn, P P

    2001-10-01

    The authors describe the case of a 37-year-old patient who sustained a subcapital femoral neck fracture six months after ICLH double-cup hip resurfacing. As the polyethylene acetabular resurfacing component was undamaged and well fixed, a standard femoral stem with a bipolar head was inserted. The outer diameter of the bipolar head was chosen to fit the resurfacing socket. The "tripolar" hip arthroplasty has functioned well for 19 years and was revised for aseptic cup loosening. The cemented femoral stem was still well fixed and was not revised. Although the "tripolar" hip has functioned well in our case, we believe it is not indicated for metal on metal bearings. In this case the use of an appropriate modular head with a correct head-socket clearance is preferred.

  19. Postoperative Pain Management After Primary Total Knee Arthroplasty: The Value of Liposomal Bupivacaine.

    Science.gov (United States)

    Sporer, Scott M; Rogers, Thea

    2016-11-01

    Multimodal pain protocols have been proposed to achieve improved long-acting postoperative analgesia. Controlling postoperative pain after joint arthroplasty is especially important as it relates to patient satisfaction and outcomes. The purpose of this study was to compare the postoperative pain, time to ambulation, and overall narcotic usage between patients who received either a femoral nerve block with a periarticular bupivacaine injection or a periarticular bupivacaine and extended-release liposomal bupivacaine injection after primary total knee arthroplasty. A total of 597 consecutive primary total knee arthroplasties performed between September 1, 2012 and August 31, 2014 received preoperative celecoxib, oxycodone, and transdermal scopolamine. Intraoperatively, patients either received a single-dose bupivacaine femoral nerve block along with 30-mL 0.25% bupivacaine periarticular injection (group A) or a 60-mL periarticular injection alone (20-mL liposomal bupivacaine, 30-mL 0.25% bupivacaine, and 10-mL saline; group B). The postoperative pain scores, narcotic usage, and time to ambulation were retrospectively collected from the electronic medical record. These outcomes were compared between treatment groups. There were 325 patients in group A compared with 272 in group B during the time frame. There was no difference among age, gender, race, and body mass index between the groups. Group B demonstrated a decreased need for breakthrough pain medication (16.9% vs 36.3% P bupivacaine resulted in a decrease need for breakthrough pain medication, improved pain scores at 12 hours, and an earlier time to ambulation compared to a combined femoral nerve block and periarticular bupivacaine injection. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Focal femoral condyle resurfacing.

    LENUS (Irish Health Repository)

    Brennan, S A

    2013-03-01

    Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed. Cite this article: Bone Joint J 2013;95-B:301-4.

  1. Total femur arthroplasty for revision hip failure in osteogenesis imperfecta: limits of biology

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz, PhD, MD

    2017-09-01

    Full Text Available Osteogenesis imperfecta (OI is a rare congenital disease characterized by alterations in bone quality, with susceptibility to fractures, instability, deformities, and osteoarthrosis. Prosthetic surgery in these patients is associated with an abnormally high rate of implant failures. On the other hand, abnormal bone fragility adds to the complexity of revision surgery in such individuals—thus representing a genuine challenge for the orthopaedic surgeon. We present a case of femoral reconstruction in a patient with OI and prosthetic loosening after reconstruction secondary to femoral septic pseudoarthrosis. Intramedullary total femoral reconstruction was carried out after exceeding the biological reconstruction limits. This is the first reported instance of the use of an intramedullary total femur arthroplasty as salvage technique in an OI patient. This technique should be considered when we have exceeded biological limits for femoral fixation.

  2. Subchondral Insufficiency Fracture of the Femoral Head in a Pregnant Woman with Pre-existing Anorexia Nervosa.

    Science.gov (United States)

    Kasahara, Kyoko; Mimura, Tomohiro; Moritani, Suzuko; Kawasaki, Taku; Imai, Shinji; Tsuji, Shunichiro; Kimura, Fuminori; Murakami, Takashi

    2018-05-01

    Subchondral insufficiency fracture (SIF) is a fragility fracture secondary to osteoporosis that leads to collapse of the femoral head with no evidence of osteonecrosis. SIF of the femoral head has been reported in adults of varying ages and both sexes, but it has never been reported to occur in pregnant women. Herein, we describe a 40-year-old primiparous patient with pre-existing anorexia nervosa who developed SIF of the femoral head in the third trimester. At 29 weeks of gestation, the patient complained of sudden pain on walking in both hips. Despite the bed rest, her hip pain increased; consequently, cesarean section was performed at 36 weeks. After delivery, plain radiographs showed that the left femoral head was collapsed. Dual-energy X-ray absorptiometry indicated that the patient was osteoporotic. The magnetic resonance imaging (MRI) of her hips showed the findings that were compatible with SIF. Her left hip pain worsened during follow-up, and a radiograph showed progressive collapse of the left femoral head. The patient then underwent left bipolar hip arthroplasty 18 months after delivery, and she was diagnosed with SIF histopathologically. This is the first report of SIF in a pregnant woman that may reflect pregnancy-associated osteoporosis. SIF in pregnancy might be overlooked or misdiagnosed because the MRI findings have several overlaps with those of other hip disorders. Precise diagnosis of SIF in pregnancy may contribute to a better outcome by avoiding early arthroplasty in young women and appropriate evaluation of the osteopenic status of the patient.

  3. Femoral head fracture without hip dislocation

    Directory of Open Access Journals (Sweden)

    Aggarwal Aditya K

    2013-10-01

    Full Text Available 【Abstract】Femoral head fractures without dislocation or subluxation are extremely rare injuries. We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high en- ergy trauma due to road traffic accident. He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39. He received cementless total hip replacement. At latest follow-up of 2.3 years, functional outcome was excellent with Harris hip score of 95. Such isolated injuries have been described only once in the literature and have not been classified till now. The purpose of this report is to highlight the extreme rarity, possible mechanism involved and a novel classification system to classify such injuries. Key words: Femur head; Hip dislocation; Classification; Arthroplasty, replacement, hip

  4. Bone density in relation to failure in patients with osteosynthesized femoral neck fractures

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Lauritsen, Jens

    2011-01-01

    Background The treatment of femoral neck fracture with internal fixation (IF) is recommended in younger patients and has compared to arthroplasty the advantage of retaining the femoral head. A big problem with osteosynthesis is though failure. Finding predictors for fixation failure is still......,2 (75,4-79,0). Failure is defined as revision surgery or new fracture. Results 69 patients had a t-score (total hip) below -2,5 SD as defined for osteoporosis. At 1 year the overall (dislocated) failure rate was 34,5 % (44,7 %), at 2 years 45,4 % (60,0 %) and at end of follow-up 49,6 % (62...

  5. The value of FDG-PET in patients with painful total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Stumpe, Katrin D.M.; Schulthess, Gustav K. von; Strobel, Klaus [University Hospital, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Romero, Jose [Orthopaedic University Hospital Balgrist, Orthopaedic Surgery, Zurich (Switzerland); Center for Joint Diseases at Hirslanden Clinic, EndoClinic Zurich, Zurich (Switzerland); Ziegler, Oliver [Orthopaedic University Hospital Balgrist, Orthopaedic Surgery, Zurich (Switzerland); Ortho Zentrum Rosenheim, Rosenheim (Germany); Kamel, Ehab M. [University Hospital, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV), Division of Nuclear Medicine, Lausanne (Switzerland); Hodler, Juerg [Orthopaedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland)

    2006-10-15

    The purpose of this study was to evaluate{sup 18}F-fluorodeoxyglucose (FDG) uptake in patients with painful total knee arthroplasty and to relate FDG uptake to the location of soft tissue pain. Twenty-eight patients with painful total knee arthroplasty had a clinical examination, standard radiographs, CT measurement of rotation of the femoral component and FDG-PET (18 PET/CT, 10 PET). The diagnosis of infection was based on microbiological examinations of surgical specimens (n=12) or clinical follow-up for at least 6 months (n=16),{sup 99m}Tc-labelled monoclonal antibody scintigraphy and joint aspiration. Twenty-seven of 28 patients presented with diffuse synovial FDG uptake. Additional focal extrasynovial FDG uptake was observed in 19 knees. Twenty-four of the 28 patients had a diagnosis of internal femoral malrotation. The remaining four patients showed no rotation (0 ) and 3 , 4 and 7 of external rotation, respectively. Three patients presented with the additional diagnosis of an infected total knee replacement. Pain was described as diffuse (n=10) or focal (n=18). In two knees a relationship between pain location and FDG uptake was observed. Of ten patients with a severe internal femoral component rotation (>6 ), seven had focal uptake, four in the femoral periosteum and three in the tibial periosteum. The difference between knees with severe malrotation and the remaining knees was not significant (p=1.000, Fisher's Exact Test). Diffuse synovial and focal extrasynovial FDG-PET uptake is commonly found in patients with malrotation of the femoral component and is not related to pain location. The information provided by FDG-PET does not contribute to the diagnosis and management of individual patients with persistent pain after total knee replacement. (orig.)

  6. The value of FDG-PET in patients with painful total knee arthroplasty

    International Nuclear Information System (INIS)

    Stumpe, Katrin D.M.; Schulthess, Gustav K. von; Strobel, Klaus; Romero, Jose; Ziegler, Oliver; Kamel, Ehab M.; Hodler, Juerg

    2006-01-01

    The purpose of this study was to evaluate 18 F-fluorodeoxyglucose (FDG) uptake in patients with painful total knee arthroplasty and to relate FDG uptake to the location of soft tissue pain. Twenty-eight patients with painful total knee arthroplasty had a clinical examination, standard radiographs, CT measurement of rotation of the femoral component and FDG-PET (18 PET/CT, 10 PET). The diagnosis of infection was based on microbiological examinations of surgical specimens (n=12) or clinical follow-up for at least 6 months (n=16), 99m Tc-labelled monoclonal antibody scintigraphy and joint aspiration. Twenty-seven of 28 patients presented with diffuse synovial FDG uptake. Additional focal extrasynovial FDG uptake was observed in 19 knees. Twenty-four of the 28 patients had a diagnosis of internal femoral malrotation. The remaining four patients showed no rotation (0 ) and 3 , 4 and 7 of external rotation, respectively. Three patients presented with the additional diagnosis of an infected total knee replacement. Pain was described as diffuse (n=10) or focal (n=18). In two knees a relationship between pain location and FDG uptake was observed. Of ten patients with a severe internal femoral component rotation (>6 ), seven had focal uptake, four in the femoral periosteum and three in the tibial periosteum. The difference between knees with severe malrotation and the remaining knees was not significant (p=1.000, Fisher's Exact Test). Diffuse synovial and focal extrasynovial FDG-PET uptake is commonly found in patients with malrotation of the femoral component and is not related to pain location. The information provided by FDG-PET does not contribute to the diagnosis and management of individual patients with persistent pain after total knee replacement. (orig.)

  7. Hip arthroplasty today and tomorrow.

    Science.gov (United States)

    Amstutz, H C

    1987-12-01

    Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.

  8. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads.

    Science.gov (United States)

    Bragdon, Charles R; Greene, Meridith E; Freiberg, Andrew A; Harris, William H; Malchau, Henrik

    2007-09-01

    This study used radiostereometric analysis (RSA) to compare the femoral head penetration of 28- vs 36-mm-diameter femoral heads into highly cross-linked polyethylene in 2 groups of total hip arthroplasty patients. Thirty patients were enrolled in this RSA study using highly cross-linked polyethylene (Longevity, Zimmer Inc, Warsaw, Idaho) against either 28- or 36-mm-diameter cobalt chrome femoral heads. At 3-year follow-up, there was no significant difference in the total average femoral head penetration, including both creep and wear, using 3 methods of RSA measurement between the 2 groups. Importantly, after bedding-in, there was no further significant increase in the amount of femoral head penetration (ie, wear) with either head size between years 1 and 3. There were no radiographic signs of lysis or radiolucencies at a minimum 3-year follow-up.

  9. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  10. A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint.

    Science.gov (United States)

    Achten, Juul; Parsons, Nick R; Edlin, Richard P; Griffin, Damian R; Costa, Matthew L

    2010-01-14

    Hip replacement (arthroplasty) surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional implants. Hip resurfacing is a relatively new arthroplasty technique. In a recent review of the literature on resurfacing arthroplasty it was concluded that the short-term functional results appear promising but some potential early disadvantages were identified, including the risk of femoral neck fracture and collapse of the head of the femur. The aim of the current study is to assess whether there is a difference in functional hip scores at one year post-operation between Total Hip Arthroplasty and Resurfacing Arthroplasty. Secondary aims include assessment of complication rates for both procedures as well cost effectiveness. All patients medically fit for surgery and deemed suitable for a resurfacing arthroplasty are eligible to take part in this study. A randomisation sequence will be produced and administered independently. After consenting, all patients will be clinically reviewed and hip function, quality of life and physical activity level will be assessed through questionnaires. The allocated surgery will then be performed with the preferred technique of the surgeon. Six weeks post-operation hip function will be assessed and complications recorded. Three, six and 12 months post-operation hip function, quality of life and physical activity level will be assessed. Additional information about patients' out-of-pocket expenses will also be collected. Current Controlled Trials ISRCTN33354155. UKCLRN portfolio ID 4093.

  11. Successful staged hip replacement in septic hip osteoarthritis in osteopetrosis: a case report

    Directory of Open Access Journals (Sweden)

    Manzi Giovanni

    2012-04-01

    Full Text Available Abstract Background Osteopetrosis is a rare, inherited, bone disorder, characterized by osteosclerosis, obliteration of the medullary cavity and calcified cartilage. The autosomal dominant form is compatible with a normal life span, although fractures often result from minimal trauma, due to the pathologic nature of bone. Osteomyelitis is common in patients with osteopetrosis because of a reduced resistance to infection, attributed to the lack of marrow vascularity and impairment of white cell function. Only one case of osteomyelitis of the proximal third of the femur has been previously reported, treated with several repeated debridements and finally with femoral head resection. Here we present for the first time a case of a staged implant of a cementless total hip prosthesis for the treatment of a septic hip in femoral neck nonunion in osteopetrosis. Case presentation A 36-years-old woman, affected by autosomal dominant osteopetrosis was referred to our department because of a septic hip arthritis associated with femoral neck septic non-union, with draining fistulas. The infection occurred early after a plate osteosynthesis for a closed perthrocanteric fracture of the femur and persisted in spite of osteosynthesis removal, surgical debridement and external fixation. In our hospital the patient underwent accurate debridement, femoral head and greater trochanter resection, preparation of the diaphyseal intramedullary canal and implant of an antibiotic-loaded cement spacer. The spacer was exchanged after one month, due to infection recurrence and four months later, a cementless total hip arthroplasty was implanted, with no clinical and laboratory signs of infection recurrence at two years follow-up. Conclusions In case of hip septic arthritis and proximal femur septic non-union, femoral head resection may not be the only option available and staged total hip arthroplasty can be considered.

  12. Coupling failure between stem and femoral component in a constrained revision total knee arthroplasty.

    LENUS (Irish Health Repository)

    Butt, Ahsan Javed

    2013-02-01

    Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use of a cemented femoral stem, screw fixation and the metaphyseal sleeve of an S-ROM modular hip system (DePuy international Ltd).

  13. Clinical study on 44 cases of femoral hernia

    International Nuclear Information System (INIS)

    Yamamoto, Ryo; Shinozaki, Hiroharu; Kase, Kenichi; Kobayashi, Kenji; Sasaki, Junichi

    2012-01-01

    Femoral hernia is a surgical disease that is frequently associated with incarceration and necessitates emergency surgery. However, there are only a few studies referred which have compared emergency and elective surgery for femoral hernias. We retrospectively reviewed the clinical characteristics of patients diagnosed as having femoral hernia between 2005 and 2009 in our institution. The clinical features of emergency repairs were compared with those of elective ones, and diagnostic values of preoperative diagnostic modalities were studied. The mean age of the patients was 73±12 years. Females comprised 68% of the cases, and right femoral hernias comprised 70% of the cases. Incarceration was associated with 66% of the cases (29 patients), and emergency surgery was performed in 52% of the patients (23 patients). Bowel resection was performed in 32% of the cases (14 patients). The mean age, body temperature, white blood cell (WBC) count, and LDH value were higher in the emergency repairs than in the elective one, and most of the hernias were repaired with McVay's procedure. CT scans had a high diagnostic value in detecting femoral hernias (44%) and incarceration (88%). It was confirmed that femoral hernias were frequently associated with incarceration and CT scan has a high diagnostic value in femoral hernias. (author)

  14. Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape.

    Science.gov (United States)

    Kim, Jong-Min; Hong, Soo-Heon; Kim, Jong-Min; Lee, Bum-Sik; Kim, Dong-Eun; Kim, Kyung-Ah; Bin, Seong-Il

    2015-07-01

    The aim of this study was to determine (1) variations in the shape of the proximal, middle, and distal femur in a series of Korean patients who had undergone total knee arthroplasty (TKA), (2) the preoperative relationship between these three parameters and the distal valgus cutting angle referenced off the femoral intramedullary guide, and (3) whether there was any relationship between femoral bowing and variations in the shape of the proximal or distal femur in the coronal plane. The preoperative long-standing anteroposterior radiographs of 316 consecutive osteoarthritis patients who underwent primary TKA from 2009 to 2011 were examined. The femoral neck shaft angle, the femoral shaft bowing angle, and the mechanical lateral distal femoral angle were measured to assess the shape of the proximal, middle, and distal femur, respectively. The valgus cutting angle of the femur was defined as the angle between the distal anatomical and mechanical axes of the femur. The study population showed large variations in femoral shape. The mean femoral intramedullary guide angle was 6.5° ± 1.3° (range: 4°-13°). The femoral shaft bowing angle was the factor that showed the strongest correlation with this angle (P shaft angle showed no correlation (n.s.). The femoral shaft bowing angle showed a weak correlation with the mechanical lateral distal femoral angle (P = 0.001), but was not significantly correlated with the femoral neck shaft angle (n.s.). Apparent femoral bowing (>3° of lateral or medial bowing) was found in 42 (13.3 %) of cases (37 cases of lateral bowing and five of medial bowing). Cases with lateral apparent femoral bowing >3° had a distal cutting angle of 8.6° ± 2.2° relative to the femoral intramedullary guide. The femoral intramedullary guide angle was mainly influenced by femoral shaft bowing among femoral deformities in the coronal plane. Therefore, to increase the accuracy of distal femoral cut during TKA, it is necessary to confirm femoral

  15. Relation between lower extremity alignment and proximal femur anatomy. Parameters during total hip arthroplasty.

    Science.gov (United States)

    Ollivier, M; Parratte, S; Lecoz, L; Flecher, X; Argenson, J-N

    2013-09-01

    Lower extremity alignment correlates with native femoral offset. Eventual impact of the change in femoral offset induced by total hip arthroplasty (THA) on lower extremity alignment has not been documented. THA significantly changes lower extremity alignment, and the change correlates with the change in femoral offset. We conducted a prospective study of 200 patients with primary hip osteoarthritis or avascular femoral head necrosis who underwent cementless THA. Pre-operative computed-tomography templating was performed and the femoral component was then custom-manufactured to replicate the native femoral anatomy. Mean age was 58 years (range, 28-83 years). Before and at least two years after THA, two observers who were not involved in the surgical procedures used standing antero-posterior long-leg radiographs to determine the mechanical axis of the lower-limb (hip-knee-ankle [HKA] angle), femoral offset, neck-shaft angle (NSA), and lower-limb length discrepancy (LLLD). Mean values pre-operatively and at last follow-up were as follows: HKA angle, 179.2° ± 3.9° (range, 170.5° to 190.5°) and 177.7° ± 3.5°(range, 173° to 187°); LLLD, -0.7 mm (range, -30 mm to +25 mm) and +5.1 mm (range, -7 mm to +21 mm); NSA, 134° ± 7.5° (range, 100° to 124°) and 135° ± 4.2° (range, 124° to 146°); and femoral offset, 42 ± 7.8 mm (range, 24 mm to 68 mm) and 49 ± 7.5 mm (range, 33 mm to 70 mm). Although THA significantly altered lower-limb alignment, univariate and multivariate analyses showed no significant association between the change in HKA angle and the change in femoral offset. Lower-limb alignment was significantly affected by THA, although the HKA angle changes were small. The small impact of THA on HKA angle values may be ascribable to efforts aimed at replicating the native femoral offset during arthroplasty, as well as to the limited sample size and to potential measurement errors related to the small size of the changes. Our results suggest that

  16. Primary cemented total hip arthroplasty: 10 years follow-up

    Directory of Open Access Journals (Sweden)

    Nath Rajendra

    2010-01-01

    Full Text Available Background: Primary cemented total hip arthroplasty is a procedure for non-traumatic and traumatic affections of the hip. Long term follow-up is required to assess the longevity of the implant and establish the procedure. Indo-Asian literature on long term result of total hip arthroplasty is sparse. We present a 10-year follow-up of our patients of primary cemented total hip arthroplasty. Materials and Methods: We operated 31 hips in 30 patients with primary cemented total hip arthroplasty. We followed the cases for a minimum period of 10 years with a mean follow-up period of 12.7 years. The mean age of the patients was 60.7 years (range 37-82 yrs male to female ratio was 2:1. The clinical diagnoses included - avascular necrosis of femoral head (n=15, sero positive rheumatoid arthritis (n=5, seronegative spondylo-arthropathy (n=4, neglected femoral neck fractures (n=3, healed tubercular arthritis (n=2 and post traumatic osteoarthritis of hip (n=2. The prostheses used were cemented Charnley′s total hip (n=12 and cemented modular prosthesis (n=19. The results were assessed according to Harris hip score and radiographs taken at yearly intervals. Results: The mean follow-up is 12.7 yrs (range 11-16 yrs Results in all operated patients showed marked improvement in Harris hip score from preoperative mean 29.2 to 79.9 at 10 years or more followup. However, the non-inflammatory group showed more sustained long term improvement as compared to the inflammatory group, as revealed by the Harris hip score. Mean blood loss was 450ml (±3.7 ml, mean transfusion rate was 1.2 units (±.3. The complications were hypotension (n=7, shortening> 1.5 cm (n=9, superficial infection (n=2 and malposition of prosthesis (n=1. Conclusion: The needs of Indian Asian patients, vary from what is discussed in literature. The pain tolerance is greater than western population and financial constraints are high. Thus revision surgery among Indian-Asian patients is less compared

  17. Persistent non-specific FDG uptake on PET imaging following hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Hongming; Chacko, Thomas K.; Hickeson, Marc; Stevenson, Karen; Feng, Qi; Ponzo, Fabio; Alavi, Abass [Division of Nuclear Medicine, Department of Radiology, The Hospital of University of Pennsylvania, 110 Donner Building, 3400 Spruce Street, Philadelphia, PA 19104 (United States); Garino, Jonathan P. [Department of Orthopedic Surgery, The Hospital of University of Pennsylvania, Philadelphia, PA 19802 (United States)

    2002-10-01

    Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean{+-}SD: 80.4{+-}86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the

  18. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Directory of Open Access Journals (Sweden)

    Baldev Dudani

    2015-01-01

    Conclusion: Bipolar hip arthroplasty (BHA using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage.

  19. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  1. PEEK-OPTIMA? as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    OpenAIRE

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components art...

  2. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  3. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    Science.gov (United States)

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  4. Comparison of Outcomes of Total Hip Arthroplasty between Patients with Ankylosing Spondylitis and Avascular Necrosis of the Femoral Head.

    Science.gov (United States)

    Lee, Sun-Ho; Lee, Gun-Woo; Seol, Young-Jun; Park, Kyung-Soon; Yoon, Taek-Rim

    2017-09-01

    The objective of this study was to compare clinical and radiological outcomes of total hip arthroplasty (THA) between ankylosing spondylitis (AS) of the hip joint and avascular necrosis (AVN) of the femoral head. Thirty patients (30 hips) underwent cementless THA for AS between 2003 and 2012. They were compared to 30 patients (30 hips) who underwent the same procedure for AVN of the femoral head. Each group was matched for age and gender, and both groups had similar preoperative demographic characteristics. All cases were followed for minimum 4 postoperative years. Clinical evaluation was based on operation time, intraoperative blood loss, quantity of postoperative drainage, Harris Hip Score (HHS), and range of motion (ROM). Radiological results were evaluated by acetabular cup anteversion and inclination, femoral stem orientation, pre- and postoperative leg length discrepancy, and postoperative complications. The operation time was significantly longer in the AS group (120.2 ± 26.2 min) than in the AVN group (79.5 ± 11.1 min). The volume of postoperative drainage was significantly greater in the AS group (764.5 ± 355.4 mL vs. 510.5 ± 195.6 mL). Preoperative HHS was lower in the AS group (55.6 ± 13.8 vs. 59.2 ± 2.8). Similarly, postoperative HHS was significantly lower in the AS group (92.8 ± 2.7 vs. 97.4 ± 2.6). The arc of ROM was improved from 146.5° ± 13.2° preoperatively to 254.7° ± 17.2° postoperatively in the AS group and from 182.6° ± 15.5° to 260.4° ± 13.7° in the AVN group. Implant position and postoperative leg length discrepancy were not different between the groups. However, three cases of heterotopic ossification was observed in the AS group, whereas only 1 case was found in the AVN group. One deep infection and one aseptic stem loosening were found in the AS group, whereas none was observed in the AVN group. Cementless THA showed satisfactory clinical and radiological results in both groups, despite the longer operation time

  5. The innovation trap: modular neck in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Samo Karel Fokter

    2017-04-01

    Full Text Available Background: Innovations play the key role in the success of orthopaedic surgery. However, even minor modifications in the established concepts and proven designs may result in disasters. The endemic of modular femoral neck fracture (24 cases of about 4000 implanted in fully modular total hip arthroplasty, popular in our country for the last 20 years, seems to challenge us with such an unfortunate consequences. The aim of this report was to analyze the extent and the causes of the problem on the one hand and to propose possible solutions on the other.Methods: Literature search for problems associated with Profemur Z (or earlier versions with the same taper-cone design fully-modular femoral stem made of titanium alloy (Ti6Al4V was performed, and hip arthroplasty registries were searched to evaluate the failure rates of the mentioned design. Mechanisms of failure were studied to get in-depth understanding of this particular hip reconstruction device.Results: Since 2010 onwards, several case reports on catastrophic modular femoral neck fractures of Profemur Z were published. Te frst Slovenian case was described in 2012. The first two larger series with modular femoral neck fractures were published in 2016. Te Australian Joint Replacement Registry was the first to discover increased revision rates due to fractures of this hip reconstruction system. Public Agency of the Republic of Slovenia for Medicinal Products and Medical Devices (JAZMP received frst two reports regarding Profemur Z modular neck complication from abroad in 2010, the first Slovenian report was received in 2012, and altogether 7 reports from Slovenian hospitals were received until December 2016. Corrosion at the neck-taper interface, where two equal or different materials are subject to constant wear in the presence of body fluids, is assumed to be responsible for the unacceptable high failure rate.Conclusions: Manufacturers are responsible to produce and market only safe devices

  6. Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report.

    Science.gov (United States)

    Wroblewski, B M; Siney, P D; Fleming, P A

    2005-09-01

    We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no femoral or acetabular component showed loosening or osteolysis.

  7. Numerical analysis of variations in posterior cruciate ligament properties and balancing techniques on total knee arthroplasty loading.

    NARCIS (Netherlands)

    Zelle, J.; Heesterbeek, P.J.; De Waal Malefijt, M.; Verdonschot, Nicolaas Jacobus Joseph

    2010-01-01

    Total knee arthroplasty (TKA) is a widely used and successful orthopaedic procedure. During TKA, the posterior cruciate ligament (PCL) can either be retained or substituted by a post-cam mechanism. One of the main functions of the PCL is to facilitate femoral rollback during knee flexion. For

  8. MRI-guidance in percutaneous core decompression of osteonecrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kerimaa, Pekka; Vaeaenaenen, Matti; Ojala, Risto; Tervonen, Osmo; Blanco Sequeiros, Roberto [Oulu University Hospital, Department of Radiology (Finland); Hyvoenen, Pekka; Lehenkari, Petri [Oulu University Hospital, Department of Surgery (Finland)

    2016-04-15

    The purpose of this study was to evaluate the usefulness of MRI-guidance for core decompression of avascular necrosis of the femoral head. Twelve MRI-guided core decompressions were performed on patients with different stages of avascular necrosis of the femoral head. The patients were asked to evaluate their pain and their ability to function before and after the procedure and imaging findings were reviewed respectively. Technical success in reaching the target was 100 % without complications. Mean duration of the procedure itself was 54 min. All patients with ARCO stage 1 osteonecrosis experienced clinical benefit and pathological MRI findings were seen to diminish. Patients with more advanced disease gained less, if any, benefit and total hip arthroplasty was eventually performed on four patients. MRI-guidance seems technically feasible, accurate and safe for core decompression of avascular necrosis of the femoral head. Patients with early stage osteonecrosis may benefit from the procedure. (orig.)

  9. MRI-guidance in percutaneous core decompression of osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Kerimaa, Pekka; Vaeaenaenen, Matti; Ojala, Risto; Tervonen, Osmo; Blanco Sequeiros, Roberto; Hyvoenen, Pekka; Lehenkari, Petri

    2016-01-01

    The purpose of this study was to evaluate the usefulness of MRI-guidance for core decompression of avascular necrosis of the femoral head. Twelve MRI-guided core decompressions were performed on patients with different stages of avascular necrosis of the femoral head. The patients were asked to evaluate their pain and their ability to function before and after the procedure and imaging findings were reviewed respectively. Technical success in reaching the target was 100 % without complications. Mean duration of the procedure itself was 54 min. All patients with ARCO stage 1 osteonecrosis experienced clinical benefit and pathological MRI findings were seen to diminish. Patients with more advanced disease gained less, if any, benefit and total hip arthroplasty was eventually performed on four patients. MRI-guidance seems technically feasible, accurate and safe for core decompression of avascular necrosis of the femoral head. Patients with early stage osteonecrosis may benefit from the procedure. (orig.)

  10. Histologic evaluation of the bone-ceramic interface of an alumina ceramic cup arthroplasty retrieved after 25 years in vivo

    Directory of Open Access Journals (Sweden)

    Fuminori Higuchi, MD

    2016-09-01

    Full Text Available A 47-year-old man underwent ceramic cup arthroplasty when he was 22 years old. Revision total hip arthroplasty was performed 25 years later because of limited range of motion without implant loosening. Histologic examination revealed that the femoral head and ceramic implant were well fixed through a thin fibrous membrane. The energy-dispersive X-ray analysis indicated that calcium and phosphorus were detected in the same peak pattern as cancellous bone in the bone-ceramic interface.

  11. Macroscopic and microscopic findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Alexandru, D O; Kamal, C K; Streba, C T; Grecu, D; Mogoantă, L

    2012-01-01

    The avascular necrosis of the femoral head is an illness induced by the cutoff of blood flow to the femoral head and it affects mostly young adults between the ages of 30 and 50 years, raising therapeutic and diagnostic issues. Many risk factors are incriminated in the development of avascular necrosis of the femoral head like: trauma, chronic alcohol consumption, smoking, administration of corticosteroid drugs, most of the cases are considered to be idiopathic. The main goal of our paper is to describe the macroscopic and microscopic variations of the bone structure, which occur in patients with avascular necrosis of the femoral head. The biological material needed for our study was obtained following hip arthroplasty surgery in 26 patients between the ages of 29 and 59 years, which previously were diagnosed with avascular necrosis of the femoral head and admitted in the Orthopedics Department of the Emergency County Hospital of Craiova (Romania) between 2010 and 2011. From a macroscopic point of view, we found well defined areas of necrosis, most of which were neatly demarcated of the adjacent viable tissue by hyperemic areas, loss of shape and contour of the femoral head and transformations of the articular cartilage above the area of necrosis. When examined under the microscope, we found vast areas of fibrosis, narrow bone trabeculae, obstructed blood vessels or blood vessels with clots inside, hypertrophic fat cells, bone sequestration but also small cells and pyknotic nuclei. The microscopic and macroscopic findings on the femoral head sections varied with the patients and the stage of the disease.

  12. Total hip arthroplasty at the rothman institute.

    Science.gov (United States)

    Austin, Matthew S; Higuera, Carlos A; Rothman, Richard H

    2012-07-01

    Total hip arthroplasty (THA) is one of the most successful surgical interventions devised in modern times. Attempts to change the current THA procedure with unproven innovations bring the risk of increased failure rates while trying to improve the benefit of the surgery. This manuscript examines the evolution of THA at the Rothman Institute illustrating the key elements that lead the success of this procedure at this institution. These key elements include femoral stem design, use of highly crossed-linked polyethylene and use of pain and rehabilitation protocols. We attempted to describe the long-term results regarding safety, effectiveness, and durability of specific THA implant designs used at this institution drawing on reported evidence in the literature. The authors performed a review of peer-reviewed articles related to the Rothman Institute's experience with THA. Total hip arthroplasty is an efficient, safe, and durable procedure. It is a highly successful operation to restore function and improve pain. The survivorship of THA procedures at the Rothman Institute is higher than 99% at 10 years based on mechanical failure. The use of collarless, tapered wedge femoral stem, highly crossed-linked polyethylene, and improved pain rehabilitation protocols have contributed to this success. There is a well-documented long-term survivorship after THA. Future innovation in THA should address new challenges with younger and more demanding patients, rather than change current methods that have a proven good survivorship. This innovation depends mainly upon improvements in the bearing surfaces and advances in pain control and rehabilitation.

  13. Radiologic assessment of the outcome of Keller and Brandes arthroplasty for hallux rigidus

    International Nuclear Information System (INIS)

    Breitenseher, M.J.; Toma, C.D.; Gottsauner-Wolf, F.; Imhof, H.

    1996-01-01

    The aim of this study was to evaluate the pre- and postoperative radiographic findings of hallux rigidus treated with Keller and Brandes arthroplasty to determine the radiographic outcome and to identify a prognostic marker. 83 patients with a total of 121 cases of hallux rigidus operated using Keller and Brandes arthroplasty were followed up (mean 9.7 y). A comparison of the pre- and postoperative radiographs, the clinical and subjective findings was predicated on a five point scale: 1. Percentage of proximal phalanx resected ( 50%), 2. joint space, 3. ratio of the length of the first and second metatarsals, 4. first intermetatarsal angle, and 5. hallux valgus angle. In the patient group which had 33-50% of the proximal phalanx excised (n=67. 55%) the highest patient satisfaction was observed (96%). If resection of the proximal phalanx exceeded 50% (n=13. 11%), non physiologic dorsiflexion of the toe occurred and patients were unsatisfied (62%). Excision of less than 33% of the hallux (n=41. 34%) was associated with a recurrent hallux rigidus. No other evaluated radiological parameter proved to be of significance. The most important radiological parameter in the evaluation of the outcome of Keller and Brandes arthroplasty as the percentage of the proximal phalanx which had ben excised. (orig.) [de

  14. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size

    International Nuclear Information System (INIS)

    Davila, Jesse A.; Kransdorf, Mark J.; Duffy, Gavan P.

    2006-01-01

    The purpose of our study was to assess the accuracy of a computer-assisted templating in the surgical planning of patients undergoing total hip arthroplasty utilizing EndoMap software (Siemans AG, Medical Solutions, Erlangen, Germany). Endomap Software is an electronic program that uses DICOM images to analyze standard anteroposterior radiographs for determination of optimal prosthesis component size. We retrospectively reviewed the preoperative radiographs of 36 patients undergoing uncomplicated primary total hip arthroplasty, utilizing EndoMap software, Version VA20. DICOM anteroposterior radiographs were analyzed using standard manufacturer supplied electronic templates to determine acetabular and femoral component sizes. No additional clinical information was reviewed. Acetabular and femoral component sizes were assessed by an orthopedic surgeon and two radiologists. Mean and estimated component size was compared with component size as documented in operative reports. The mean estimated acetabular component size was 53 mm (range 48-60 mm), 1 mm larger than the mean implanted size of 52 mm (range 48-62 mm). Thirty-one of 36 acetabular component sizes (86%) were accurate within one size. The mean calculated femoral component size was 4 (range 2-7), 1 size smaller than the actual mean component size of 5 (range 2-9). Twenty-six of 36 femoral component sizes (72%) were accurate within one size, and accurate within two sizes in all but four cases (94%). EndoMap Software predicted femoral component size well, with 72% within one component size of that used, and 94% within two sizes. Acetabular component size was predicted slightly better with 86% within one component size and 94% within two component sizes. (orig.)

  15. Radiofrequency ablation of two femoral head chondroblastomas

    Energy Technology Data Exchange (ETDEWEB)

    Petsas, Theodore [Department of Radiology, University of Patras (Greece); Megas, Panagiotis [Department of Orthopaedic Surgery, University of Patras (Greece)]. E-mail: panmegas@med.upatras.gr; Papathanassiou, Zafiria [Department of Radiology, University of Patras (Greece)

    2007-07-15

    Chondroblastoma is a rare benign cartilaginous bone tumor. Surgical resection is the treatment of choice for pain relief and prevention of further growth. Open surgical techniques are associated with complications, particularly when the tumors are located in deep anatomical sites. The authors performed RF ablation in two cases of subarticular femoral head chondroblastomas and emphasize its positive impact. The clinical course, the radiological findings and the post treatment results are discussed.

  16. Low friction arthroplasty and dual mobility cup: a new gold standard.

    Science.gov (United States)

    Prudhon, Jean Louis; Verdier, Régis; Caton, Jacques H

    2017-03-01

    Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.

  17. A Three-arm Randomized Clinical Trial Comparing Continuous Femoral Plus Single-injection Sciatic Peripheral Nerve Blocks versus Periarticular Injection with Ropivacaine or Liposomal Bupivacaine for Patients Undergoing Total Knee Arthroplasty.

    Science.gov (United States)

    Amundson, Adam W; Johnson, Rebecca L; Abdel, Matthew P; Mantilla, Carlos B; Panchamia, Jason K; Taunton, Michael J; Kralovec, Michael E; Hebl, James R; Schroeder, Darrell R; Pagnano, Mark W; Kopp, Sandra L

    2017-06-01

    Multimodal analgesia is standard practice for total knee arthroplasty; however, the role of regional techniques in improved perioperative outcomes remains unknown. The authors hypothesized that peripheral nerve blockade would result in lower pain scores and opioid consumption than two competing periarticular injection solutions. This three-arm, nonblinded trial randomized 165 adults undergoing unilateral primary total knee arthroplasty to receive (1) femoral catheter plus sciatic nerve blocks, (2) ropivacaine-based periarticular injection, or (3) liposomal bupivacaine-based periarticular injection. Primary outcome was maximal pain during postoperative day 1 (0 to 10, numerical pain rating scale) in intention-to-treat analysis. Additional outcomes included pain scores and opioid consumption for postoperative days 0 to 2 and 3 months. One hundred fifty-seven study patients received peripheral nerve block (n = 50), ropivacaine (n = 55), or liposomal bupivacaine (n = 52) and reported median maximal pain scores on postoperative day 1 of 3, 4, and 4.5 and on postoperative day 0 of 1, 4, and 5, respectively (average pain scores for postoperative day 0: 0.6, 1.7, and 2.4 and postoperative day 1: 2.5, 3.5, and 3.7). Postoperative day 1 median maximal pain scores were significantly lower for peripheral nerve blockade compared to liposomal bupivacaine-based periarticular injection (P = 0.016; Hodges-Lehmann median difference [95% CI] = -1 [-2 to 0]). After postanesthesia care unit discharge, postoperative day 0 median maximal and average pain scores were significantly lower for peripheral nerve block compared to both periarticular injections (ropivacaine: maximal -2 [-3 to -1]; P bupivacaine: maximal -3 [-4 to -2]; P bupivacaine over ropivacaine in periarticular injections for total knee arthroplasty.

  18. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    , 31-A2) and intertrochanteric (31-A3) fractures is considered an important approach because of their different behaviour at reduction. Pertrochanteric fractures occurred more frequently (81.5%); the patients' age was higher (80 years on the average) and women outnumbered men at a ratio of 3:1. Intertrochanteric fractures were found in significantly younger patients (average, 72 years), with a women-to-men ratio of 1.3:1. Stable pertrochanteric fractures (31-A1) were preferably indicated for DHS surgery. Unstable pertrochanteric (31-A2) and intertrochanteric (31- A3) fractures were treated with a nail. The patients underwent surgery on the day of injury or the next day. In the case of contraindications to an urgent intervention, surgery was performed after the patient's medical condition had stabilised. The number of complications was largely related to technical errors, such as insufficient reduction or an incorrectly inserted implant. Intertrochanteric fractures were associated with a higher occurrence of complications. No implant can compensate for errors due to surgery. Serious complications can be reduced by the correct assessment of fracture type, the use of an appropriate operative technique and early treatment of potential complications. The necessity of restoring continuity in the medial cortex of the femoral neck (Adams' arch) is the requirement that should be observed. Pseudoarthrosis or varus malalignment in a healed hip should be managed by valgus osteotomy. When the femoral head or the acetabulum is damaged, total hip arthroplasty is indicated. A prerequisite for successful surgical outcome is urgently and correctly performed osteosynthesis allowing for early rehabilitation and mobilisation of the patient.

  19. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    Science.gov (United States)

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  20. Patient specific instrumentation in total knee arthroplasty: a state of the art

    Science.gov (United States)

    Mattei, Lorenzo; Pellegrino, Pietro; Bistolfi, Alessandro; Castoldi, Filippo

    2016-01-01

    Patient specific instrumentation (PSI) is a modern technique in total knee arthroplasty (TKA) aiming to facilitate the implant of the prosthesis. The customized cutting blocks of the PSI are generated from pre-operative three-dimensional model, using computed tomography (CT) or magnetic resonance imaging (MRI). A correct surgical plan is mandatory for a good surgical implant. The PSI guide takes into account any slight deformities or osteophytes and applies preoperative planning for bone resection, using the pre-determined implant size, position, and rotation. The apparent benefits of this technology are that neutral postoperative alignment is more reproducible, surgical time is decreased, and the entire procedure results more efficient and cost-effective. The use of PSI is indicated when advanced osteoarthritis, severe pain, and limited function/walking ability are present, such as in a standard instrumentation TKA. In addition to that, PSI finds its indication when intra-medullary guides cannot be used. For example, when there is a post-traumatic femoral deformity. Large debates have taken place about this topic during the last years and, at the moment, there is no consensus in literature regarding the accuracy and reliability of PSI as many studies have shown controversial and inconsistent results. Literature does not suggest PSI techniques as a gold standard in TKA, and therefore it cannot be recommended as a standard technique in standard, not complicated primary TKA. Moreover, literature does not underline any improvement in components alignment, surgical time, blood loss or functional outcomes. Nevertheless, many patients who underwent TKA suffered a previous trauma. In case of deformities, like femoral or tibial fractures healed with a malalignment, preoperative planning may result difficult, and some intra-operative technical difficulties can occur, such as the use of intra-medullar rod. In these selected cases, PSIs may be very useful to avoid errors in

  1. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  2. Comparison of anatomic vs. straight femoral stem design in total hip replacement - femoral canal fill in vivo.

    Science.gov (United States)

    de Boer, Friso A; Sariali, Elhadi

    2017-05-12

    The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.

  3. The mechanical effect of the existing cement mantle on the in-cement femoral revision.

    LENUS (Irish Health Repository)

    Keeling, Parnell

    2012-08-01

    Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct.

  4. THE INFLUENCE OF THE SURGICAL APPROACH CONCERNING DISLOCATION IN TOTAL HIP ARTHROPLASTY.

    Science.gov (United States)

    Vicente, José Ricardo Negreiros; Pires, André Fernandes; Lee, Bruno Takasaki; Leonhardt, Marcos Camargo; Ejnisman, Leandro; Croci, Alberto Tesconi

    2009-01-01

    Our primary aim was to evaluate the occurrence of dislocation of non-cemented total hip arthroplasty, when using the posterior and the direct lateral approaches. We performed a comparative retrospective study with 232 patients submitted to non-cemented total hip arthroplasty, due to the diagnosis of primary or secondary osteoarthritis. The posterior approach was used in 105 patients while direct lateral approach was used in 127 patients. There was only one prosthesis model and the same rehabilitation program and post-operative care was used for all patients. We checked the occurrence of dislocation, the acetabular positioning and also the size of the components. There was only one case of dislocation, treated with closed reduction successfully. This was a 47 year-old female, submitted to direct lateral approach. The mean follow-up time for both groups was 23.7 months, ranging from six to 42 months. The authors conclude that the prevalence of total hip arthroplasty dislocation is similar for both approaches, and educational measures besides the use of a higher femoral offset seem to reduce the risk of this complication.

  5. Arthroplasty of hip resection, handling with external fixation - Experience in the central military hospital

    International Nuclear Information System (INIS)

    Satizabal Azuero, Carlos E; Calderon Uribe, Oscar; Naquira Escobar, Luis F

    2006-01-01

    This is an observational retrospective study series of cases carried out between January 1998 and July 2004 in the central military hospital, 13 patients were treated with Girdlestone arthroplasty with external fixation, with a pursuit average of 53 months. Function, return to the daily activities and associate complications was evaluated. They were as complication; pain in the fixator site, osteitis, and fixator broke. All patients report at the end of the treatment no pain in the hip. Shortening in the patient without lenghting was 3,5 cm and in the group with lenghting was 1.5 cm. the obtained results demonstrate that Girdlestone arthroplasty with external fixation, is option, to improve the patient's pain and function of the hip

  6. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    Science.gov (United States)

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  7. Identification of hip surface arthroplasty failures with TcSC/TcmDP radionuclide imaging

    International Nuclear Information System (INIS)

    Thomas, B.J.; Amstutz, H.C.; Mai, L.L.; Webber, M.M.

    1982-01-01

    The roentgenographic identification of femoral component loosening after hip surface arthroplasty is often impossible because the metallic femoral component obscures the bone-cement interface. The use of combined technetium sulfur colloid and technetium methylene diphosphonate radionuclide imaging has been especially useful in the diagnosis of loosening. In 40 patients, follow-up combined TcSC and TcmDP scans at an average of three, nine, and 27 months postoperation revealed significant differences in the isotope uptakes in patients who had loose prostheses compared with those without complications. Scans were evaluated by first dividing them into eight anatomical regions and then rating the uptake in each region or 'zone' on a five-point scale. Results were compared using the Student's t-test and differences were noted between normal controls and patients who had femoral component loosening. Combining both TcSC and TcmDP studies increased the statistical significance obtained when comparing patients who had complications to those in the control group

  8. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Nina; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head whil...... a matching metal cup is placed in the acetabulum (pelvis socket)....

  9. Fractura por fatiga de un tallo de revisión femoral modular cónico estriado de fijación distal.

    Directory of Open Access Journals (Sweden)

    Martin Buttaro

    2013-03-01

    Full Text Available 1. Engelbrecht E, Heinert K. Klassifikation und Behandlungsrichtlinien von Knochensubsanzverlusten bei Revisionsoperationen am Huftgelenk mittelfrsige Ergebnisse. Primare und Revisionsalloarthroplastik Hrsg-Endo-Klinik, Hamburg: Springer-Verlag, Berlin; 1987:189. 2. Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 1954;36:451. 3. Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mat Res 1983;17:829. 4. Carlsson AS, Gentz CF, Stenport J. Fracture of the femoral prosthesis in total hip replacement according to Charnley. Acta Orthop Scand 1977;48:650-5. 5. Chao EYS, Coventry MB. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg Am 1981;63:1078-94. 6. Charnley J. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthop 1975;111:105. 7. Buttaro M, Mayor M, Van Citters D, Piccaluga F. Fracture of a proximally modular, distally fluted uncemented implant with diaphyseal fixation. J Arthroplasty 2007;22(5:780-3. 8. Bohm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg Am 2001;83(7:1023. 9. Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am 1997;79(12:1842.

  10. [Are Higher Prices for Larger Femoral Heads in Total Hip Arthroplasty Justified from the Perspective of Health Care Economics? An Analysis of Costs and Effects in Germany].

    Science.gov (United States)

    Grunert, R; Schleifenbaum, S; Möbius, R; Sommer, G; Zajonz, D; Hammer, N; Prietzel, T

    2017-02-01

    Background: In total hip arthroplasty (THA), femoral head diameter has not been regarded as a key parameter which should be restored when reconstructing joint biomechanics and geometry. Apart from the controversial discussion on the advantages and disadvantages of using larger diameter heads, their higher cost is another important reason that they have only been used to a limited extent. The goal of this study was to analyse the price structure of prosthetic heads in comparison to other components used in THA. A large group of patients with hip endoprostheses were evaluated with respect to the implanted socket diameter and thus the theoretically attainable head diameter. Materials and Methods: The relative prices of various THA components (cups, inserts, stems and ball heads) distributed by two leading German manufacturers were determined and analysed. Special attention was paid to different sizes and varieties in a series of components. A large patient population treated with THA was evaluated with respect to the implanted cup diameter and therefore the theoretically attainable head diameter. Results: The pricing analysis of the THA components of two manufacturers showed identical prices for cups, inserts and stems in a series. In contrast to this, the prices for prosthetic heads with a diameter of 36-44 mm were 11-50 % higher than for 28 mm heads. Identical prices for larger heads were the exception. The distribution of the head diameter in 2719 THA cases showed significant differences between the actually implanted and the theoretically attainable heads. Conclusion: There are proven advantages in using larger diameter ball heads in THA and the remaining problems can be solved. It is therefore desirable to correct the current pricing practice of charging higher prices for larger components. Instead, identical prices should be charged for all head diameters in a series, as is currently established practice for all other THA components. Thus when

  11. Is There an Inherent Risk to Damage the Popliteus Tendon by Femoral Component With Inbuilt External Rotation? A Pilot Study in Indian Knees.

    Science.gov (United States)

    Chouhan, Dervendra Kumar; Dhillon, Mandeep S

    2016-02-01

    Femoral components with inbuilt rotation require thicker flexion resection of the lateral femoral condyle and could have a potential risk of damaging the popliteus tendon, especially in the smaller Asian knees. We prospectively evaluated 10 patients with bilateral varus osteoarthritis knee to size the cuts and their location in relation to the popliteus tendon. Two different types of implant were used on either side; one side requires resection in 3° external rotation (group A) and the other side requires a femoral component with inbuilt external rotation (group B). We observed the incidence of injury to the popliteus tendon and distance between flexion cut to its attachment over the lateral femoral condyle between both groups. We had popliteus tendon injury in 3 knees all from group B. Risk of damaging the popliteus tendon was found higher in group B, as the distance between flexion cut to popliteus tendon attachment was significantly low. Femoral component with inbuilt external rotation has more risk of injuring the popliteus tendon because flexion cut takes out more bone from the lateral femoral condyle. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty

    NARCIS (Netherlands)

    Marra, Marco A.; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan A.W.; Janssen, Dennis; Koopman, Bart F.J.M.; Verdonschot, Nico; Wymenga, Ate B.

    2018-01-01

    Purpose: When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm,

  13. Early Clinical and Radiographic Results of Minimally Invasive Anterior Approach Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Tamara Alexandrov

    2014-01-01

    consecutive patients with 43 total hip arthroplasties performed through an anterior muscle sparing minimally invasive approach. We found the early complication rates and radiographic outcomes comparable to those reported from arthroplasties performed via traditional approaches. Complications included dislocation (2%, femur fracture (2%, greater trochanteric fracture (12%, postoperative periprosthetic intertrochanteric fracture (2%, femoral nerve palsy (5%, hematoma (2%, and postoperative iliopsoas avulsion (2%. Radiographic analysis revealed average cup anteversion of 19.6°±6.6, average cup abduction angle of 48.4°±7, stem varus of 0.9°±2, and a mean leg length discrepancy of 0.7 mm. The anterior approach to the hip is an attractive alternative to the more traditional approaches. Acceptable component placement with comparable complication rates is possible using a muscle sparing technique which may lead to faster overall recovery.

  14. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty?

    Science.gov (United States)

    Müller, M; Abdel, M P; Wassilew, G I; Duda, G; Perka, C

    2015-12-01

    The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck-shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck-shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes. In total, 44 patients (mean age 65.3 years (standard deviation (SD) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (SD 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck-shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes. The mean pre-operative neck-shaft angle was significantly increased by 2.8° from 128° (SD 6.2; 119° to 147°) to 131° (SD 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (SD 8; 7.9 to 39.1) and reduced to 7.4° (SD 7.3; -11.6° to 25.9°) post-operatively (p shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck-shaft angles, but without any impact on clinical outcome. ©2015 The British Editorial Society of Bone & Joint Surgery.

  15. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  16. Italian experience on use of E.S.W. therapy for avascular necrosis of femoral head.

    Science.gov (United States)

    Russo, Sergio; Sadile, Francesco; Esposito, Roberto; Mosillo, Giuseppe; Aitanti, Emanuele; Busco, Gennaro; Wang, Ching-Jen

    2015-12-01

    Osteonecrosis (avascular necrosis) of the femoral head is a clinical disease due to a severe bone vascular alteration associated with intense pain and loss of joint function, with an incidence of 0.1% and unknown aetiology. Many classifications exist to describe it and in the final stages the patient will need a total hip arthroplasty. In the early stages, ESWT has given excellent responses.
 The Neapolitan school studied more than 600 patients who had very good results in I and II stages of Ficat and Arlet Classification, with an improve of outcomes in VAS and HSS scores. Moreover it has shown a complete restoration of the signal intensity of the femoral head in MRI. Copyright © 2015. Published by Elsevier Ltd.

  17. Fracture of the femoral component after a lightning strike injury: A case report

    Directory of Open Access Journals (Sweden)

    Xavier Lizano-Díez

    2017-01-01

    Full Text Available A fracture of the stem in a total hip arthroplasty (THA is an uncommon complication. We report a case of femoral stem fracture in a 55-year-old male patient after a lightning strike. A revision was conducted using a Wagner osteotomy and a revision prosthesis. Dall-Milles cerclages were used to close the osteotomy. The postoperative evolution was satisfactory, with an immediate partial weight bearing, consolidation of the osteotomy after three months and return to daily activity without pain.

  18. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty; Valutazione con Tomografia Computerizzata della rotazione delle componenti femorale e tibiale nell'artroprotesi totale del ginocchio

    Energy Technology Data Exchange (ETDEWEB)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). Servizio di Diagnostica per Immagini; Trentani, F.; Trentani, P.; Tigani, D. [Istituto Ortopedico Rizzoli, Bologna (Italy). VII Div.; Nigrosoli, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). IV Div.

    2000-06-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteria were prosthesis loosening and severe (equal or superior to 7 degrees) varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  19. Pathological femoral fractures due to osteomalacia associated with adefovir dipivoxil treatment for hepatitis B: a case report

    Directory of Open Access Journals (Sweden)

    Tanaka Motoyuki

    2012-08-01

    Full Text Available Abstract We present a case of a 62-year-old man who underwent total hip arthroplasty for treatment of pathologic femoral neck fracture associated with adefovir dipivoxil-induced osteomalacia. He had a 13-month history of bone pain involving his shoulders, hips, and knee. He received adefovir dipivoxil for treatment of lamivudine-resistant hepatitis B virus infection for 5 years before the occurrence of femoral neck fracture. Orthopedic surgeons should be aware of osteomalacia and pathological hip fracture caused by drug-induced renal dysfunction, which results in Fanconi’s syndrome. Virtual slides The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1600344696739249

  20. Pathological femoral fractures due to osteomalacia associated with adefovir dipivoxil treatment for hepatitis B: a case report

    Science.gov (United States)

    2012-01-01

    We present a case of a 62-year-old man who underwent total hip arthroplasty for treatment of pathologic femoral neck fracture associated with adefovir dipivoxil-induced osteomalacia. He had a 13-month history of bone pain involving his shoulders, hips, and knee. He received adefovir dipivoxil for treatment of lamivudine-resistant hepatitis B virus infection for 5 years before the occurrence of femoral neck fracture. Orthopedic surgeons should be aware of osteomalacia and pathological hip fracture caused by drug-induced renal dysfunction, which results in Fanconi’s syndrome. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1600344696739249 PMID:22906214

  1. Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics : a musculoskeletal simulation study

    NARCIS (Netherlands)

    Marra, Marco Antonio; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan A.W.; Janssen, Dennis W.; Koopman, Bart F.J.M.; Wymenga, Ate B.; Verdonschot, Nico J.J.

    2017-01-01

    Purpose: In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior

  2. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  3. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Science.gov (United States)

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  4. Fracture of the acetabulum with femoral artery injury presenting late: A case report

    Directory of Open Access Journals (Sweden)

    Sivaprasad Kalyanasundaram

    2016-02-01

    Full Text Available This study reports a rare case of both column acetabulum fracture with femoral artery injury that presented late and was managed with arterial reconstruction and fracture fixation.A thirty-one year old man sustained both column acetabular fracture on the left in a motor vehicle accident. On admission there was no obvious neuro-vascular deficit. During surgery for the fracture after 7 days of the injury the femoral artery was found to be severely crushed with no blood flow. The anterior column of the acetabulum was stabilised followed by resection and reconstruction of the femoral artery. The post-operative period was uneventful and he was discharged normally. At 6 months from injury the fractures had united well with excellent limb circulation and good lower limb function.Femoral artery injury with acetabular fracture is rare and late presentations are unreported hitherto. The results of fracture stabilisation and vessel reconstruction seem to be excellent. Literature of similar injuries is reviewed. Keywords: Acetabular fractures, Both column fractures, Anterior column fractures, Vascular injury, Femoral artery injury

  5. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

    Science.gov (United States)

    Price, A J; Short, A; Kellett, C; Beard, D; Gill, H; Pandit, H; Dodd, C A F; Murray, D W

    2005-11-01

    Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

  6. Results of cemented bipolar hemiarthroplasty for fracture of the femoral neck - 10 year study

    Directory of Open Access Journals (Sweden)

    Maini P

    2006-01-01

    Full Text Available Background : One of the most common treatments of displaced fracture of femoral neck in elderly is bipolar hemiarthroplasty. Method : Two hundred and seventy patients of displaced fracture of femoral neck were treated by bipolar hemiarthroplasty. The Mean age of the patients at the time of surgery was 69.80 years. Results : Follow up ranged between 12 months and 120 months. There were 8 cases each of acetabular erosion and protrusion with 10 cases of femoral stem loosening. Eight cases had post operative dislocation requiring open reduction. Eighteen patients got revision surgery to total hip replacement. The overall incidence of DVT/PE was 9.9% which declined after regular use of low molecular weight heparin. Eleven patients had post operative infection. There were 54.2 % excellent results, 21.0 % good results, 10.7 % fair and 3.7% poor results. Conclusion : Elderly patients with displaced fracture of neck femur are able to ambulate early after Cemented bipolar hemi arthroplasty. The complication rate is low, the component survival long and pre injury functional status is restored in majority of patients.

  7. High failure rate after internal fixation and beneficial outcome after arthroplasty in treatment of displaced femoral neck fractures in patients between 55 and 70 years.

    Science.gov (United States)

    Bartels, Stefan; Gjertsen, Jan-Erik; Frihagen, Frede; Rogmark, Cecilia; Utvåg, Stein Erik

    2018-02-01

    Background and purpose - The treatment of patients between 55 and 70 years with displaced intracapsular femoral neck fracture remains controversial. We compared internal fixation (IF), bipolar hemiarthroplasty (HA) and total hip arthroplasty (THA) in terms of mortality, reoperations and patient-reported outcome by using data from the Norwegian Hip Fracture Register. Patients and methods - We included 2,713 patients treated between 2005 and 2012. 1,111 patients were treated with IF, 1,030 with HA and 572 patients with THA. Major reoperations (defined as re-osteosynthesis, secondary arthroplasty, exchange, or removal of prosthesis components and Girdlestone procedure), patient-reported outcome measures (satisfaction, pain, and health-related quality of life (EQ5D) after 4 and 12 months), 1-year mortality, and change in treatment methods over the study period were investigated. Results - Major reoperations occurred in 27% after IF, 3.8% after HA and 2.8% after THA. 549 patients (20% of total study population) answered both questionnaires. Compared with IF, patients treated with THA were more satisfied after 4 and 12 months, reported less pain after 4 months and 12 months, had a higher EQ5D-index score after 4 months and 12 months, and EQ-VAS score after 4 months. Compared with IF, patients treated with HA were more satisfied and reported less pain after 4 months. EQ5D-index and EQ-VAS were similar. Patients treated with HA had higher 1-year mortality and had more comorbidities than both the THA and IF group. All these differences were statistically and clinically significant. Interpretation - This study showed high reoperation rate after IF and better patient-reported outcome after both THA and HA with medium follow-up. Patients selected for HA represented a frailer group than patients treated with THA or IF.

  8. Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty.

    Science.gov (United States)

    Meneghini, R Michael; Lovro, Luke R; Wallace, Joseph M; Ziemba-Davis, Mary

    2016-03-01

    Trunnionosis has reemerged in modern total hip arthroplasty for reasons that remain unclear. Bearing frictional torque transmits forces to the modular head-neck interface, which may contribute to taper corrosion. The purpose of this study is to compare frictional torque of modern bearing couples in total hip arthroplasty. Mechanical testing based on in vivo loading conditions was used to measure frictional torque. All bearing couples were lubricated and tested at 1 Hz for more than 2000 cycles. The bearing couples tested included conventional, highly crosslinked (XLPE) and vitamin E polyethylene, CoCr, and ceramic femoral heads and dual-mobility bearings. Statistical analysis was performed using Student t test for single-variable and analysis of variance for multivariant analysis. P ≤ .05 was considered statistically significant. Large CoCr metal heads (≥36 mm) substantially increased frictional torque against XLPE liners (P = .01), a finding not observed in ceramic heads. Vitamin E polyethylene substantially increased frictional torque compared with XLPE in CoCr and ceramic heads (P = .001), whereas a difference between conventional and XLPE was not observed (P = .69) with the numbers available. Dual-mobility bearing with ceramic inner head demonstrated the lowest mean frictional torque of all bearing couples. In this simulated in vivo model, large-diameter CoCr femoral heads and vitamin E polyethylene liners are associated with increased frictional torque compared with smaller metal heads and XLPE, respectively. The increased frictional torque of vitamin E polyethylene and larger-diameter femoral heads should be considered and further studied, along with reported benefits of these modern bearing couples. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. [SURGICAL HIP DISLOCATION APPROACH FOR TREATMENT OF FEMORAL HEAD FRACTURE].

    Science.gov (United States)

    Tang, Yanfeng; Liu, Youwen; Zhu, Yingjie; Li, Jianming; Li, Wuyin; Li, Qiyi; Jia, Yudong

    2015-11-01

    To discuss the value of surgical hip dislocation approach in the treatment of femoral head fracture. A retrospectively analysis was made on the clinical data of 15 patients with femoral head fractures treated through surgical hip dislocation approach between January 2010 and February 2013. There were 11 men and 4 women with an average age of 30.8 years (range, 15-63 years). The causes included traffic accident injury in 9 cases, falling injury from height in 5 cases, and sports injury in 1 case. According to Pipkin typing, 2 cases were rated as type I, 7 cases as type II, 1 case as type III, and 5 cases as type IV. The interval of injury and operation was 2-10 days (mean, 4.1 days). Reduction was performed in 10 patients within 6 hours after injury, and then bone traction was given for 4-6 weeks except 5 patients who received reduction in the other hospital. Primary healing of incision was obtained in all patients after surgery without complications of dislocation and lower limbs deep venous thrombosis. The mean follow-up time was 29.9 months (range, 25-36 months). During follow-up, there was no infection, breakage of internal fixation, or nonunion of femoral greater trochanter fracture. In 3 patients having necrosis of the femoral head, 2 had no obvious symptoms [staging as IIa and IIb respectively according to Association Research Circulation Osseous (ARCO) staging system], and 1 (stage IIIb) had nonunion of the femoral neck fracture, who underwent total hip arthroplasty (THA). In 4 patients having myositis ossificans (2 cases of grade I, 1 case of grade II, and 1 case of grade III based on Brooker grading), no treatment was given in 3 cases and the focus was removed during THA in 1 case. According to the Thompson-Epstein scale at last follow-up, the results were excellent in 9 cases, good in 3 cases, fair in 1 case, and poor in 2 cases, and the excellent and good rate was 80%. Surgical hip dislocation approach can not only protect the residual vessels of the

  10. The role of acetabulum geometry and femoral head-neck ratio in the development of osteoarthritis in young men

    DEFF Research Database (Denmark)

    Halle, B; Halle, D M; Torfing, T

    2007-01-01

    and the consequence of acetabular retroversion on standardized x-rays. Men aged 26-55 years who earlier had a total hip arthroplasty were included in the case group. This group was compared to a control-group of men treated as trauma patients. The study indicates that acetabular dysplasia and retroversion......We studied the role of acetabulum geometry and head neck ratio in the development of osteoarthritis of the hip in young men. Contrary to previous studies we evaluated the significance of the anterior, posterior and total coverage of the femoral head, the influence of the femoral neck...... and a relative decreased head neck ratio are associated with osteoarthritis of the hip in young men....

  11. Aloenxerto circunferencial de femur proximal em cirurgia de revisäo de artroplastia total de quadril: relato de casos com seguimento mínimo de 20 anos Circumferential proximal femoral allografts in revision surgery on total hip arthroplasty: case reports with a minimum follow-up of 20 years

    Directory of Open Access Journals (Sweden)

    Bruno Dutra Roos

    2012-01-01

    Full Text Available Dentre as opções para reconstrução femoral em cirurgias de revisão de artroplastia total do quadril (RATQ em defeitos circunferenciais extensos está a utilização de aloenxerto de fêmur proximal. O seu uso permite a correção do mecanismo abdutor do quadril e da discrepância de comprimento dos membros inferiores, além de apresentar potencial osteocondutivo. Os autores relatam os achados clínicos e radiográficos de dois casos de RATQ com uso desta técnica, em seguimento mínimo de 20 anos.Among the options for femoral reconstruction in total hip arthroplasty (THA revision procedures, in cases of extensive circumferential defects, is the use of proximal femoral allografts. This technique makes it possible to correct the hip abductor mechanism and the leg length discrepancy, as well as presenting osteoconductive potential. The authors report the clinical and radiographic results from two cases of THA revision using this technique, with a minimum follow-up of 20 years.

  12. Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2013-01-01

    Full Text Available Management of recurrent dislocation of total hip arthroplasty is often a challenging and daunting task. Re-revision of such a total hip prosthesis may not be easy as the removal of a well-fixed, fully coated stem is extremely difficult. We managed to salvage instability in three revision hip cases in which the fully coated stem had subsided by using a bioball universal neck adapter without changing the femoral stem or acetabular cup.

  13. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.

    Science.gov (United States)

    Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H

    2017-05-01

    The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

    Science.gov (United States)

    Bonin, Nicolas; Gedouin, Jean-Emmanuel; Pibarot, Vincent; Bejui-Hughues, Jacques; Bothorel, Hugo; Saffarini, Mo; Batailler, Cécile

    2017-10-03

    Even if the benefits of collars are unclear, they remain widely used, in several femoral stem designs. This study aimed to determine whether collar size should be proportional to hip dimensions and morphology. The hypothesis was that the collar should be larger for greater stem sizes and for varus femoral necks. Computed Tomography scans of 204 healthy hips were digitally analysed and manually templated to determine principle dimensions, appropriate stem size and model, as well as cortical distance at the femoral calcar (ideal collar size). Univariable analysis revealed that cortical distance was moderately correlated with mediolateral offset (r = 0.572; p < 0.0001) and stem model (r = 0.520; p < 0.0001). Cortical distance was weakly correlated with head diameter (r = 0.399; p < 0.0001), stem size (r = 0.200; p = 0.017), and patient gender (r = 0.361; p < 0.0001). Multivariable analysis confirmed that stem model (p < 0.0001) and head diameter (p = 0.0162) are directly correlated to cortical distance. We found that cortical distance along the femoral calcar is directly correlated with the model of the stem implanted ('standard' or 'varus') and with the head diameter. This cortical distance indicates optimal collar size, which would grant maximum calcar coverage without prosthetic overhang. Collar size should be proportional to the size of the operated hip, and should be larger for 'varus' stem models than for 'standard' stem models.

  15. [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

    Science.gov (United States)

    Bonnaire, F; Lein, T; Bula, P

    2011-06-01

    The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by

  16. Risk factors for revision of primary total hip arthroplasty: a systematic review

    Directory of Open Access Journals (Sweden)

    Prokopetz Julian JZ

    2012-12-01

    Full Text Available Abstract Background Numerous papers have been published examining risk factors for revision of primary total hip arthroplasty (THA, but there have been no comprehensive systematic literature reviews that summarize the most recent findings across a broad range of potential predictors. Methods We performed a PubMed search for papers published between January, 2000 and November, 2010 that provided data on risk factors for revision of primary THA. We collected data on revision for any reason, as well as on revision for aseptic loosening, infection, or dislocation. For each risk factor that was examined in at least three papers, we summarize the number and direction of statistically significant associations reported. Results Eighty-six papers were included in our review. Factors found to be associated with revision included younger age, greater comorbidity, a diagnosis of avascular necrosis (AVN as compared to osteoarthritis (OA, low surgeon volume, and larger femoral head size. Male sex was associated with revision due to aseptic loosening and infection. Longer operating time was associated with revision due to infection. Smaller femoral head size was associated with revision due to dislocation. Conclusions This systematic review of literature published between 2000 and 2010 identified a range of demographic, clinical, surgical, implant, and provider variables associated with the risk of revision following primary THA. These findings can inform discussions between surgeons and patients relating to the risks and benefits of undergoing total hip arthroplasty.

  17. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.

  18. The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology: Review Article.

    Science.gov (United States)

    Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio; Lepri, Andrea Cozzi; Sirleo, Luigi; Innocenti, Massimo

    2017-02-01

    Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. We performed a review of national joint registries trying to answer the following questions: "Which is the main factor directly related to revisions rate in TKA?" and "Are there new bearing options better than conventional ones?" A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.

  19. Primary Total Hip Replacement for a Femoral Neck Fracture in a Below-Knee Amputee

    OpenAIRE

    Masmoudi, Karim; Rbai, H?di; Fradj, Ayman Ben; Sa?dena, Jecem; Boughattas, Anouar

    2016-01-01

    Introduction: Femoral neck fracture on amputated limb is an uncommon lesion and challenging to manage. Case Report: We report a case of a displaced neck fracture of the left femur in a 57-year-old female. She underwent at the age of the three a below-knee amputation of the ipsilateral limb for post traumatic ischemia. The fracture was managed by a total hip arthroplasty (THA), as a primary procedure. In this article we describe our experience of this unusual entity. Conclusion: Total hip arth...

  20. Review of a single contemporary femoral neck fracture fixation method in young patients.

    LENUS (Irish Health Repository)

    Henari, Shwan

    2011-03-01

    An intracapsular femoral neck fracture in a young patient is a rare and difficult injury to manage. The occurrence of complications following fixation is multifactorial. Initial displacement and timing and accuracy of reduction are the key factors affecting outcome. The severities of the trauma to the hip and the impact of the intracapsular hematoma also play a role, the importance of which remains poorly understood. The purpose of this study was to evaluate the high incidence of femoral neck fractures treated in our institution over a 7-month period, to record the long-term outcome of these patients, all of whom were treated with contemporary methods of internal fixation, and to highlight the reasons for this injury being termed an "orthopedic emergency" and its differences from the same injury in the elderly population. We performed a retrospective analysis of 12 cases of intracapsular femur neck fracture in patients younger than 50 years treated over 7 months in a regional trauma center. All patients underwent satisfactory reduction and fixation. Nine of the 12 patients had a good outcome at a mean follow-up of 29 months. One patient developed a nonunion of the femoral head requiring total hip arthroplasty, one developed avascular necrosis of the femoral head, and one developed partial avascular necrosis. This compares favorably with other studies.

  1. Structural and functional studies of bioobjects prepared from femoral heads

    Energy Technology Data Exchange (ETDEWEB)

    Kirilova, I. A., E-mail: IKirilova@niito.ru; Podorozhnaya, V. T., E-mail: VPodorognaya@niito.ru [Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan, 17, Frunze, Novosibirsk, 630091 (Russian Federation); Sharkeev, Yu. P., E-mail: sharkeev@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation); National Research Tomsk Polytechnic University, 30, Lenin Avenue, Tomsk, 634050 (Russian Federation); Popova, K. S., E-mail: kseniya@ispms.tsc.ru; Uvarkin, P. V., E-mail: uvarkin@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation)

    2015-11-17

    Results of examination of physicomechanical characteristics of samples of medial femoral head cuts are presented. The samples of medial femoral head cuts resected in 6 patients with coxarthrosis in primary endoprosthetic replacement of a coxofemoral joint have been tested for micro- and nanohardness. Young’s modulus and elemental composition of bone tissue have been investigated. To estimate the architectonics of cancellous tissue of the femoral head, adjacent cuts of the same patient have been analyzed. The porosity of bone tissue was estimated from macroscopic images obtained using macrophotography. The total porosity is calculated as the ratio of the total length of straight line segments overlapping pores to the total length of secants. A three-point bending test of the samples has shown that their strength changed from 0.187 to 1.650 MPa and their elasticity modulus changes from 1.69 to 8.15 MPa. The microhardness of the samples changes in the range 220–265 MPa and the average microhardness of medial femoral head cuts is 240 MPa. The elemental composition of medial femoral head cuts is represented by basic Ca, P, O, Na and Mg elements as well as by Sn, S, Fe, Cr, and C in microamounts. The atomic Ca to P ratio for bone tissue is 1.55. It is revealed that pores of the upper part of the femoral head have a more regular shape and in the lower part they are more elongated along the cut and occupy a larger volume. The lower part of the femoral head has a higher porosity (39 and 33%) than the upper part (34 and 30%). The total porosity of all samples does not exceed 37%.

  2. No effect of fibrin sealant on drain output or functional recovery following simultaneous bilateral total knee arthroplasty

    DEFF Research Database (Denmark)

    Skovgaard, Christian; Holm, Bente; Troelsen, Anders

    2013-01-01

    Background and purpose Blood loss after total knee arthroplasty (TKA) may lead to anemia, blood transfusions, and increased total costs. Also, bleeding into the periarticular tissue may cause swelling and a reduction in quadriceps strength, thus impairing early functional recovery. In this random...... in TKA showed no benefit in reducing drain output or in facilitating early functional recovery when used with a tourniquet, tranexamic acid, and a femoral bone plug....

  3. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    Science.gov (United States)

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty.

    Science.gov (United States)

    Marra, Marco A; Strzelczak, Marta; Heesterbeek, Petra J C; van de Groes, Sebastiaan A W; Janssen, Dennis; Koopman, Bart F J M; Verdonschot, Nico; Wymenga, Ate B

    2018-03-20

    When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to

  5. Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.

    Science.gov (United States)

    Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

  6. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Directory of Open Access Journals (Sweden)

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  7. Does femoral offset recover and affect the functional outcome of patients with displaced femoral neck fracture following hemiarthroplasty?

    Science.gov (United States)

    Ji, Hyung-Min; Won, Seok-Hyung; Han, Jun; Won, Ye-Yeon

    2017-06-01

    Restoring preoperative horizontal femoral offset (FO) promised good functional outcome in patients receiving total hip arthroplasty. However, relatively little was known regarding the clinical relevance of restoring the offset in patients with bipolar hemiarthroplasty to treat displaced femoral neck fracture. Therefore, the objective of this study was to evaluate postoperative FO accurately and verify its relation with functional outcome. One hundred elderly patients who received bipolar hemiarthroplasty to treat displaced femoral neck fracture were identified. Preoperative CT scanning of contralateral hip joint and reconstruction of images led to rotation-free FO. By referencing postoperative implant specification and comparing to measured values in Picture Archive and Communication System, rotation-free postoperative FO and the amount of change were acquired. Postoperative Harris Hip Score (HHS) and Modified Barthel Index (MBI) were evaluated to measure functional outcome at 12-month after the surgery. Patients with significant FO change were identified. Multiple regression analysis was conducted to determine if the FO change might independently affect the outcome regardless of confounding factors. The mean preoperative offset was 37.4±2.5 increased by 12.7±9.6% after the surgery. Only 25.0% of postoperative offset after hemiarthroplasty was changed within ±5% of preoperative offset. A total of 45.0% of postoperative offset changed within ±10% while 77.0% of postoperative offset changed within ±20%. 23% of patients whose FO changed more than 20% showed significantly worse outcome score than the patients whose FO change remained within ±20% of initial value. Mean MBI and HHS were negatively correlated with FO change. After adjusting for confounding factors, significant correlation remained between modification of FO and MBI, but not between FO change and HHS (B=4.576; β=0.235; 95% confidence interval of B: 0.534 to 8.135). FO was not properly restored in 23

  8. Failed Reverse Total Shoulder Arthroplasty Caused by Recurrent Candida glabrata Infection with Prior Serratia marcescens Coinfection

    Directory of Open Access Journals (Sweden)

    John G. Skedros

    2014-01-01

    Full Text Available This report describes a 58-year-old insulin-dependent diabetic male patient who initially sustained a proximal humerus fracture from a fall. The fracture fixation failed and then was converted to a humeral hemiarthroplasty, which became infected with Candida glabrata and Serratia marcescens. After these infections were believed to be cured with antibacterial and antifungal treatments and two-stage irrigation and debridement, he underwent conversion to a reverse total shoulder arthroplasty. Unfortunately, the C. glabrata infection recurred and, nearly 1.5 years after implantation of the reverse total shoulder, he had a resection arthroplasty (removal of all implants and cement. His surgical and pharmacologic treatment concluded with (1 placement of a tobramycin-impregnated cement spacer also loaded with amphotericin B, with no plan for revision arthroplasty (i.e., the spacer was chronically retained, and (2 chronic use of daily oral fluconazole. We located only three reported cases of Candida species causing infection in shoulder arthroplasties (two C. albicans, one C. parapsilosis. To our knowledge, a total shoulder arthroplasty infected with C. glabrata has not been reported, nor has a case of a C. glabrata and S. marcescens periprosthetic coinfection in any joint. In addition, it is well known that S. marcescens infections are uncommon in periprosthetic joint infections.

  9. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Science.gov (United States)

    Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan

    2014-01-01

    The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703

  10. Particulate metallic debris in cemented total hip arthroplasty.

    Science.gov (United States)

    Salvati, E A; Betts, F; Doty, S B

    1993-08-01

    Several studies conducted by the authors in the last six years demonstrate that the generation of metallic debris is more severe with titanium alloy than with cobalt-chrome alloy femoral components in cemented total hip arthroplasty (THA). The debris is generated from the articulating surface, particularly if entrapped acrylic debris produces three-body wear, and from the stem surface when the component loosens and abrades against fragmented cement. In selected cases in which the titanium metallic debris is copious, premature failure and severe progressive bone loss occurs. Electron microscopy demonstrates that the particles of metallic debris can be extremely small (a few hundredths of 1 micron). They are phagocytized by the macrophages and transported to the phagolysosomes. In this highly corrosive environment, the very high surface area of the particles may release toxic concentrations of the constituents of the alloy intracellularly, probably leading to progressive cell degeneration and death, with subsequent release of intracellular enzymes and ingested metallic debris. This cycle most likely repeats itself, leading to tissue necrosis. The results presented do not support the use of titanium alloy femoral components for cemented THA, particularly for the articulating surface.

  11. Three-dimensional analysis of accuracy of patient-matched instrumentation in total knee arthroplasty: Evaluation of intraoperative techniques and postoperative alignment.

    Science.gov (United States)

    Kuwashima, Umito; Mizu-Uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Akasaki, Yukio; Murakami, Koji; Nakashima, Yasuharu

    2017-11-01

    It is questionable that the accuracies of patient-matched instrumentation (PMI) have been controversial, even though many surgeons follow manufacturers' recommendations. The purpose of this study was to evaluate the accuracy of intraoperative procedures and the postoperative alignment of the femoral side using PMI with 3-dimensional (3D) analysis. Eighteen knees that underwent total knee arthroplasty using MRI-based PMI were assessed. Intraoperative alignment and bone resection errors of the femoral side were evaluated with a CT-based navigation system. A conventional adjustable guide was used to compare cartilage data with that derived by PMI intraoperatively. Postoperative alignment was assessed using a 3D coordinate system with a computer-assisted design software. We also measured the postoperative alignments using conventional alignment guides with the 3D evaluation. Intraoperative coronal alignment with PMI was 90.9° ± 1.6°. Seventeen knees (94.4%) were within 3° of the optimal alignment. Intraoperative rotational alignment of the femoral guide position of PMI was 0.2° ± 1.6°compared with the adjustable guide, with 17 knees (94.4%) differing by 3° or less between the two methods. Maximum differences in coronal and rotation alignment before and after bone cutting were 2.0° and 2.8°, respectively. Postoperative coronal and rotational alignments were 89.4° ± 1.8° and -1.1° ± 1.3°, respectively. In both alignments, 94.4% of cases were within 3° of the optimal value. The PMI group had less outliers than conventional group in rotational alignment (p = 0.018). Our 3D analysis provided evidence that PMI system resulted in reasonably satisfactory alignments both intraoperatively and postoperatively. Surgeons should be aware that certain surgical techniques including bone cutting, and the associated errors may affect postoperative alignment despite accurate PMI positioning. Copyright © 2017 The Japanese Orthopaedic Association. Published by

  12. Elevated lip liner positions improving stability in total hip arthroplasty. An experimental study.

    Directory of Open Access Journals (Sweden)

    Suleman Qurashi

    2018-01-01

    Full Text Available Background: The use of elevated lip polyethylene liners with the acetabular component is relatively common in Total Hip Arthroplasty (THA. Elevated lip liners increase stability of the THA by increasing the jump distance in one direction. However, the elevated lip, conversely, also reduces the primary arc in the opposite direction and leads to early impingement of the neck on the elevated lip, potentially causing instability. The aim of the present study is to determine the total range of motion of the femoral head component within the acetabular component with the elevated lip liner in different orientations within the acetabular cup. Methods: We introduce a novel experimental (ex-vivo framework for studying the effects lip liner orientation on the range of motion of the femoral component. For constant acetabular cup orientation, the elevated lip liner was positioned superiorly and inferiorly. The femoral component range of motion in the coronal, sagittal and axial plane was measured. To avoid any confounding influences of out of plane motion, the femoral component was constrained to move in the tested plane. Results: This experimental set up introduces a rigorous framework in which to test the effects of elevated lip liner orientations on the range of motion of the femoral head component in abduction, adduction, flexion, extension and rotation. The movements of this experimental set-up are directly informative of patient’s maximum potential post-operative range of motion. Initial results show that an inferior placement of the elevated lip increases the effective superior lateral range of motion (abduction for the femoral component, whilst the anatomy of the patient (i.e. their other leg prevents the point of femoral component – acetabular lip impingement being reached (in adduction.

  13. Trochantoplasty for Total Hip Arthroplasty in Patients With Coxa Vara Deformity.

    Science.gov (United States)

    Yoo, Jun-Il; Parvizi, Javad; Song, Ji-Ung; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2017-07-01

    In total hip arthroplasty (THA) of hips with coxa vara, the femoral stems might be inserted in a varus alignment. To avoid varus insertion, we designed a technique, which we termed "trochantoplasty." In this procedure, the medial half of the greater trochanter was removed during THA. We evaluated 30 patients (31 hips) who had coxa vara deformity and underwent THA using trochantoplasty at the mean follow-up of 5 years (range, 3-9 years). All stems were inserted in the neutral position. One Vancouver type 1 periprosthetic femoral fracture occurred after a fall at postoperative 2 months. At the latest follow-up, the mean power of abductor was 4.3 (range, 3-5). Four patients had moderate limp whereas 26 patients had slight limp. The abduction at 90° flexion ranged from 15° to 45° (mean, 35°). There was no revision. All prostheses had bone-ingrown stability without any detectable wear or osteolysis. The mean Harris hip score was improved from 66.9 to 89.4 points. Trochantoplasty can be used to avoid varus insertion of the femoral stem while performing THA in patients with coxa vara deformity without compromising the abductor mechanism. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Management of avascular necrosis of femoral head at pre-collapse stage

    Directory of Open Access Journals (Sweden)

    Sen Ramesh

    2009-01-01

    Full Text Available In osteonecrosis the success of interventions that forestall or prevent femoral head collapse and maintain hip function would represent a substantial achievement in the treatment of this disease. A review of recent literature regarding bisphosphonate, anticoagulant, and vasodilators and biophysical modalities have demonstrated efficacy in reducing pain and delaying disease progression in early stage osteonecrosis. Though it has been considered still insufficient, to support their routine use in the treatment or prevention of osteonecrosis of the hip. Core decompression with modification of technique is still one of the safest and most commonly employed procedures with evidence based success in the pre-collapse stage of AVN of femoral head. The additional use of bone morphogenic protein, and bone marrow stem cells may provide the opportunity to enhance the results of core decompression. At present, the use of large vascularised cortical grafts, the other surgical procedure with high success rate is still not common due to technical difficulty in surgery. Likewise osteotomies are also not getting common as arthroplasty is getting more acceptable, so is awaited without any intermediate big surgical interventions.

  15. Rare Case of Large Bowel Injury due to Direct Blunt Trauma to a Preexisting Femoral Hernia

    Directory of Open Access Journals (Sweden)

    C. Tinner

    2017-01-01

    Full Text Available We report a case of an 85-year-old man with a known asymptomatic left femoral hernia who was admitted to the emergency ward a few hours after falling from a bicycle and suffering from blunt trauma of the handlebar to the left inguinal region. The clinical findings and a computed tomography (CT scan detecting free air in the femoral hernia sac suggested bowel perforation. Emergency laparotomy 6 hours after the incident confirmed a tear of the sigmoid colon accompanied by free blood and faeces in the left inguinal region of the abdomen. A segmental sigmoid resection and a primary end-to-end colorectal anastomosis were performed. The postoperative course was complicated by delayed oral feeding, a local infection, and a partial left testicle necrosis that led to secondary resection. The patient was discharged after 32 days of in-hospital care. Three months post trauma, we recorded a restitutio ad integrum. The case exemplifies that blunt trauma to preexisting femoral hernias may cause potentially lethal bowel perforation and that the time interval between time of injury and surgical treatment may be a prognostic factor. CT scans seem most suitable for ruling out bowel perforation. The scarce literature for blunt trauma to hernias is reviewed.

  16. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    Science.gov (United States)

    2006-01-01

    Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a

  17. Rapidly destructive arthrosis of the hip joint in a young adult with systemic lupus erythematosus.

    Science.gov (United States)

    Lee, Yongseung; Motomura, Goro; Yamamoto, Takuaki; Nakashima, Yasuharu; Ohishi, Masanobu; Hamai, Satoshi; Iura, Kunio; Iwamoto, Yukihide

    2015-10-01

    A 37-year-old female had been treated with corticosteroids for systemic lupus erythematosus clinically diagnosed at age 10. She suddenly had right hip pain without any antecedent trauma. Four months after the onset of pain, she visited her primary care physician. On magnetic resonance imaging, joint space narrowing at the weight-bearing area was already seen with bone marrow edematous lesions in both the femoral head and acetabulum. She was treated non-operatively; however, her pain continued to worsen in severity. Thirteen months after the onset of pain, she was referred to our hospital. A plain radiograph showed subluxation of the collapsed femoral head accompanied by destruction of the acetabular rim. Because of her severe intractable pain, she underwent total hip arthroplasty 1 month after her first visit. Histological examination of the resected femoral head revealed pseudogranulomatous lesions along with prominent callus formation, suggesting rapid destruction of the femoral head.

  18. Ipsilateral Femoral Fracture Non-Union and Delayed Union Treated By Hybrid Plate Nail Fixation and Vascularized Fibula Bone Grafting: A Case Report

    Directory of Open Access Journals (Sweden)

    CK Chan

    2013-07-01

    Full Text Available Non-union is a well recognized complication of femoral neck fractures. The decision whether to attempt fracture fixation or to resort to hip replacement is particularly difficult in patients in the borderline age group in whom complex attempts at gaining union may fail and later present a difficult revision. On the other hand the patient may be young enough that arthroplasty best be avoided . Besides, presence of ipsilateral femoral shaft fracture with delayed union in addition to the femoral neck non-union will pose major problems at operation. We share our experience in treating a femoral neck fracture non-union with ipsilateral femoral shaft delayed union in the shaft and in the distal femur in a fifty years old patient. The fracture was treated with an angle blade plate and supracondylar nail supplemented with a free vascularised fibular bone grafting and autologous cancellous graft. There was radiological union at fourth month. At sixth months, the patient was free of pain and able to walk without support. Thus, we would like to suggest that vascularised fibula bone grafting with supracondylar nailing is a viable option for this pattern of fracture.

  19. Perioperative management of an elderly patient of hypertrophic obstructive cardiomyopathy for knee arthroplasty and the role of peripheral nerve blocks

    Directory of Open Access Journals (Sweden)

    Sunny Rupal

    2013-01-01

    Full Text Available This case report exemplifies how the anaesthetic technique of general anesthesia with continuous bilateral femoral nerve block for bilateral knee arthroplasty was well chosen for the management of perioperative complications in an elderly patient with hypertrophic obstructive cardiomyopathy (HOCM. A 69-year-old female patient of HOCM was scheduled for bilateral total knee replacement. Echocardiography revealed severe left ventricular outflow tract obstruction with peak systolic gradient of 56 mmHg. The surgery was conducted under general anaesthesia with invasive monitoring and bilateral continuous femoral nerve blocks for postoperative analgesia. Postoperatively, she developed pulmonary oedema due to the liberal administration of fluids. This complication was successfully managed without interrupting the management of pain. Management of patients with HOCM for noncardiac surgery requires knowledge of variable presentation of two forms of disease. Also, this case report highlights the practical advantage of continuous femoral nerve block (CFNBs over epidural anaesthesia.

  20. Trombose aguda de aneurisma de artéria femoral isolado: relato de caso Acute thrombosis of isolated femoral artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    André Hideo Motoki

    2008-12-01

    Full Text Available Aneurismas de artéria femoral são raros, porém são o segundo tipo mais freqüente de aneurismas periféricos, sendo o aneurisma de artéria poplítea o mais comum. Normalmente, são de etiologia aterosclerótica. As complicações deste aneurisma são representadas por embolia, trombose e, mais raramente, a rotura. O objetivo deste trabalho é relatar um caso de um paciente com 59 anos, masculino, com queixa de dor súbita em membro inferior esquerdo associado à frialdade, palidez e ausência de pulsos. O ecocolordoppler evidenciou a presença de aneurisma trombosado da artéria femoral comum. O paciente foi submetido, com sucesso, à ressecção do aneurisma, com reconstrução do leito arterial.Common femoral artery aneurysms are rare; however, they are the second most frequent type of peripheral aneurysm, popliteal artery aneurysms being the most common. They usually have atherosclerotic ethiology. The complications of this aneurysm are thromboembolism and, more rarely, rupture. This article aimed at reporting the case of a 59-year-old male patient with complaint of sudden pain in his left leg associated with coldness, paleness and absence of pulses. Color Doppler ultrasound showed a thrombosed aneurysm of the common femoral artery. The patient was successfully submitted to aneurysm resection with reconstruction of the arterial bed.

  1. Hip Dislocation Increases Roughness of Oxidized Zirconium Femoral Heads in Total Hip Arthroplasty: An Analysis of 59 Retrievals

    Science.gov (United States)

    Moussa, Mohamed E.; Esposito, Christina I.; Elpers, Marcella E.; Wright, Timothy M.; Padgett, Douglas E.

    2014-01-01

    The aims of this study were to assess damage on the surface of retrieved oxidized zirconium metal (OxZr) femoral heads, to measure surface roughness of scratches, and to evaluate the extent of surface effacement using scanning electron microscopy (SEM). Ceramic zirconia-toughened alumina (ZTA) heads were analyzed for comparison. OxZr femoral heads explanted for recurrent dislocation had the most severe damage (p<0.001). The median surface roughness of damaged OxZr femoral heads was 1.49μm, compared to 0.084μm for damaged ZTA heads and 0.052μm for undamaged OxZr (p<0.001). This may be of clinical concern because increased surface roughness has the potential to increase the wear of polyethylene liners articulating against these OxZr heads in THA. PMID:25443362

  2. Arthroplasty for Unreconstructable Acute Fractures and Failed Fracture Fixation About the Hip and Knee in the Active Elderly: A New Paradigm.

    Science.gov (United States)

    Kyle, Richard F; Duwelius, Paul J; Haidukewych, George J; Schmidt, Andrew H

    2017-02-15

    The techniques, materials, and designs for total joint arthroplasty underwent major improvements in the past 30 years. During this time, trauma surgeons classified the severity of fractures as well as identified certain articular fractures that do not have good outcomes and have a high rate of failure after internal fixation. Advanced improvements in arthroplasty have increased its reliability and longevity. Total joint arthroplasty is becoming a standard of care for some acute articular fractures, particularly displaced femoral neck fractures in the active elderly. Total joint arthroplasty also has become the standard of care after failed internal fixation in patients who have very complicated fractures about the knee, hip, and shoulder. As the population ages, fractures worldwide continue to rapidly increase. Elderly patients have a high risk for fractures that result from falls because of their poor bone quality. The current active elderly population participates in higher risk activities than previous elderly populations, which places them at risk for more injuries. This has become both a worldwide healthcare problem and an economic problem. Surgeons need to manage fractures in the active elderly with the latest advancements in technology and patient selection to ensure rapid recovery and the reduction of complications.

  3. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin [Asan Mecical Center, Seoul (Korea, Republic of)

    1997-07-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  4. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    International Nuclear Information System (INIS)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin

    1997-01-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  5. Transfracture abduction osteotomy: A solution for nonunion of femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Jairamchander Pingle

    2014-01-01

    femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO. Materials and Methods: Over a period of 35 years (1974-2008, 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008, All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years. Results were analyzed in terms of radiological union at six months. Average followup was five years and six months. Results: Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°. Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore′s pins. These were reopened and cancellous screws were inserted in the same tracks. Conclusions: Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks.

  6. Endotoxins in surgical instruments of hip arthroplasty.

    Science.gov (United States)

    Goveia, Vania Regina; Mendoza, Isabel Yovana Quispe; Guimarães, Gilberto Lima; Ercole, Flavia Falci; Couto, Bráulio Roberto Gonçalves Marinho; Leite, Edna Marilea Meireles; Stoianoff, Maria Aparecida Resende; Ferreira, José Antonio Guimarães

    2016-01-01

    To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method) was used. There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested. Investigar endotoxinas em instrumentais cirúrgicos esterilizados empregados em artroplastias do quadril. Estudo exploratório, descritivo, desenvolvido em um hospital público de ensino. Foram selecionados seis tipos de instrumentais, a saber: raspa acetabular, raspa femural, saca-cabeça de fêmur, formão box, fresa de fêmur e cabeça de prova de fêmur. A seleção foi feita a partir da análise da dificuldade para a remoção de resíduos de sangue e osso durante a limpeza. A amostra foi constituída por 60 instrumentais cirúrgicos, que foram testados para endotoxinas em três momentos distintos. Foi utilizado o método de gel-clot pelo Limulus Amebócito Lisado (LAL) Endosafe(tm). Houve formação de gel consistente com análise positiva em oito instrumentais, o que corresponde a 13,3%, sendo quatro raspas de fêmur e quatro fresas de fêmur. Foram detectadas endotoxinas em quantidade ≥0,125 UE/mL em 13,3% dos instrumentais testados.

  7. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Fırat Ozan

    2014-01-01

    Full Text Available The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA. Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%, good in 17 patients (53.1%, average in 5 patients (15.6%, and poor in 1 patient (9.3%. Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%, fibrous union in 12 (37.5%, and no union in 6 (18.7%. FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery.

  8. Limb shortening osteotomy in a patient with achondroplasia and leg length difference after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Christian L. Galata

    2013-07-01

    Full Text Available Introduction: Achondroplasia is the most common reason for disproportionate short stature. Normally, orthopedic limb lengthening procedures must be discussed in the course of this genetic disorder and have been successful in numerous achondroplastic patients in the past. In some cases, the disease may lead to leg length differences with need for surgical correction. Case Report: We report a case of achondroplastic dysplastic coxarthrosis with symptomatic leg length difference after bilateral total hip arthroplasty in a 52-year-old female patient, in which a distal femoral shortening osteotomy was successfully performed. Conclusion: Femoral shortening osteotomy is very uncommon in patients with achondroplasia. We conclude, however, that in rare cases it can be indicated and provide the advantage of shorter operation time, less perioperative complications and faster recovery compared to leg lengthening procedures. Keywords: Achondroplasia, dysplastic coxarthrosis, limb shortening, distal femur osteotomy.

  9. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...... system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential......., free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper...

  10. Indirect lateral surgical approach modified in hip arthroplasty

    International Nuclear Information System (INIS)

    Sanchez, Pedro Antonio; Arbelaez, William Rafael

    2006-01-01

    The authors show an another option to the surgical approach to the hip, a lateral indirect modified (ALIM) for the partial or total arthroplasty of primary hip replacement and for revision (RTC), in a retrospective study, series of cases, with average was 7,75 years of follow up (range 6 months-10 years); quick access, easy technically, provide a good orientation of the components of the placement of implants, and allow an excellent exhibition for the complex problems of the reconstruction of the acetabular and the femur. Leaves intact the greater trochanter, improving the rotational stability that is needed in its femoral implant, doesn't injured the gluteus medius and doesn't produces his deficit, reduce the time for the deambulation. This approach is designed for primary cases and complex cases of revision using the mini-incision, with better exposition and less morbid-mortality associated to the surgical technique due to the less bleeding, less incidence of dislocation, thromboembolism and infection because of the little damage and better control of the surrounding soft tissue; better stability, no paralysis or lesion of the sciatic or femoral nerve without incidence of heterotopic ossifications with a better range of external rotation in extension of the hip that with traditional approach of Hardinge, and greater versatility in its indications

  11. Risk factors of avascular necrosis of the femoral head and fixation failure in patients with valgus angulated femoral neck fractures over the age of 50 years.

    Science.gov (United States)

    Song, Hyung Keun; Choi, Ho June; Yang, Kyu Hyun

    2016-12-01

    The aim of our study was to identify the risk factors for avascular necrosis of the femoral head (AVN) and fixation failure (FF) after screw osteosynthesis in patients with valgus angulated femoral neck fractures. We conducted a retrospective study of 308 patients (mean age, 72.5 years, range, 50-97 years), with a mean follow-up of 21.4 months (range, 12-64 months). The risk for failure in treatment (FIT) associated with patient- and fracture-related factors was evaluated by logistic regression analyses. FIT was identified in 32 cases (10.3%): 22 cases (7.1%) of AVN and 10 cases (3.2%) of FF. Initial valgus tilt>15° (p=0.023), posterior tilt>15° (p=0.012), and screw sliding distance (p=0.037) were significantly associated with FIT. FIT occurred in 7 patients (5.2%) with B1.2.1 fractures and 17 patients (48.6%) with B1.1.2 fractures (p15° (B1.1.2) compared to patients with 15° are reasonable candidates for primary arthroplasty due to high risk of FIT. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Preliminary results of a randomized trial comparing 400 cGy vs 700 cGy as an adjuvant to prevent heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Nguyen, Cam; Gupta-Burt, Shalina; Silverton, Craig; Cummings, Marilyn; Galante, Jorge O.

    1997-01-01

    Purpose/Objective: We report our preliminary results of a randomized trial comparing one single dose of 400 cGy versus 700 cGy given postoperatively in an attempt to prevent heterotopic ossification after total hip arthroplasty. Materials and Methods: From 09/1993 and 05/1996, over 800 total hip replacements were performed at our hospital. From this group of patients, 120 hips in 114 high-risk patients (14%) were enrolled in a randomized trial to determine if 400 cGy (Group A) is as efficacious as 700 cGy (Group B) in preventing heterotopic ossification. In Group A, there were 42 males (46 hips) and 12 females (12 hips) with a mean age of 60 (range 41-79); with 18 primary cementless femoral components (33%), 30 primary cemented stems (55%) and 10 revisions. In Group B, there were 30 males (32 hips) and 30 females (31 hips) with a median age of 59 (range 41-85); with 12 primary cementless femoral components (20%), 44 primary cemented stems (73%) and 6 revisions. All acetabular components were of the cementless type. Patients were randomized to receive either 400 cGy or 700 cGy in one fraction. Radiotherapy is given within 48 hours post-operatively using paired anterior and posterior fields, with blocking of the cementless acetabular component and the femoral component. Results: All 114 patients were available for a minimum follow-up of 6 months (range 6-30 months). None of the arthroplasties has failed at the latest follow-up. There were no radiation therapy complications noted. Statistical analysis revealed no difference in the distribution of patients in either group according to age, sex, primary or revision arthroplasty, cemented or cementless femoral component fixation, preoperative heterotopic ossification risk, or surgical approach. Of the 58 hips in Group A, heterotopic ossification was graded as Grade 0 in 24 hips, Grade I in 10 hips, Grade II in 18 hips, Grade III in 6 hips, with no cases of Grade IV. Of the 63 hips in Group B, heterotopic ossification was

  13. Polymethylmethacrylate extrusion into the femoral nutrient vessel during arthroplasty: A phenomenon to be aware of

    Directory of Open Access Journals (Sweden)

    Steve Eastaugh-Waring

    2009-01-01

    Full Text Available Third generation cementing technique is now commonly used for total hip arthroplasty. The aim of this technique is to sufficiently pressurise the cement and allow maximal penetration of the cement into any remaining trabecular bone to provide a stable fixation of the prosthesis. We report a case where this pressurisation resulted in Polymethylmethacrylate retrograde filling of the nutrient vessel and we discuss the controversial diagnosis and current literature surrounding this rare phenomenon.

  14. Low infection rate after tumor hip arthroplasty for metastatic bone disease in a cohort treated with extended antibiotic prophylaxis

    DEFF Research Database (Denmark)

    Hettwer, Werner H; Horstmann, Peter Frederik; Hovgaard, Thea Bechmann

    2015-01-01

    tumor resection for metastatic bone disease during a 4-year period from 2010 to 2013 (n = 105 patients). Results. Intravenous antibiotic prophylaxis was administrated for an extended duration of a mean of 7.4 days. The overall infection rate was 3.6% (4/111 implants), infection free survival was 96...... suggest that extended postoperative antibiotic prophylaxis may reduce the risk of PJI in patients undergoing tumor resection and endoprosthetic replacement for metastatic bone disease associated impending or de facto pathologic fractures of the proximal femur.......Background. Compared to conventional hip arthroplasty, endoprosthetic reconstruction after tumor resection is associated with a substantially increased risk of periprosthetic joint infection (PJI), with reported rates of around 10% in a recent systematic review. The optimal duration of antibiotic...

  15. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  16. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head.

    Science.gov (United States)

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure. A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13 th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

  17. Rolamento posterior do fêmur na artroplastia total do joelho: comparação entre as próteses com preservação e com sacrifício do ligamento cruzado posterior Femoral roll back in total knee arthroplasty: comparison between prostheses that preserve and sacrifice the posterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Lúcio Honório de Carvalho Júnior

    2011-01-01

    Full Text Available OBJETIVO: Comparar a posteriorização do ponto de contato entre o componente femoral e o polietileno tibial à medida em que o joelho é fletido em dois tipos de artroplastia total do joelho, uma com sacrifício e outra com preservação do ligamento cruzado posterior (LCP. MÉTODOS: Foram analisados, sob fluoroscopia, 36 joelhos de 32 pacientes submetidos a artroplastia total do joelho. Analisando as imagens em perfil, foi medido o ponto de contato do fêmur com o polietileno tibial com o joelho em extensão completa e em 90 graus de flexão, mensurando-se o percentual de "rolamento" posterior do fêmur nas artroplastias em que o ligamento cruzado posterior (LCP foi sacrificado e naquelas nas quais esse foi preservado. RESULTADOS: O percentual médio de posteriorização do fêmur foi de 13,24% nos casos em que o LCP foi sacrificado e de 5,75% nos casos em que esse foi preservado. A diferença entre essas medidas foi estatisticamente significativa, com p = 0,026615. CONCLUSÃO: Na artroplastia total do joelho, sacrificar o LCP aumenta a translação posterior do ponto de contato entre o fêmur e a tíbia à medida em que o joelho é flexionado até 90 graus.OBJECTIVE: To compare the rollback of the contact point between the femoral component and the tibial polyethylene as the knee is flexed, in two types of total knee arthroplasty: one that sacrifices and the other that preserves the posterior cruciate ligament (PCL. METHODS: Under fluoroscopy, 36 knees from 32 patients who underwent total knee arthroplasty were evaluated. Using lateral images, the contact points between the femur and the tibial polyethylene with the knee in complete extension and at 90° of flexion were measured, thereby measuring the percentage rollback of the femur in arthroplasties in which the PCL was sacrificed and in those in which it was preserved. RESULTS: The mean percentage rollback of the femur was 13.24% in the cases in which the PCL was sacrificed and 5.75% in

  18. Still no single gold standard for using cementless femoral stems routinely in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Joseph T. Moskal, MD

    2016-12-01

    Conclusions: Using evidence-based data should be better guidance in selecting the most reliable implants for THA. Although cementless femoral fixation for THA has evolved to the “new standard,” it has not been proven to be the “gold standard” for all patients.

  19. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.

    Science.gov (United States)

    Urish, Kenneth L; Hamlin, Brian R; Plakseychuk, Anton Y; Levison, Timothy J; Higgs, Genymphas B; Kurtz, Steven M; DiGioia, Anthony M

    2017-09-01

    Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. We report on 28 patients (30 implants) with either GTF (n = 18) or head-neck taper corrosion (n = 12) of the LFIT CoCr femoral head and the Accolade titanium-molybdenum-zirconium-iron alloy femoral stems. All these cases were associated with adverse local tissue reactions requiring revision of the THA. In our series, a conservative estimate of the incidence of failure was 4.7% (n = 636 total implanted) at 8.0 ± 1.4 years from the index procedure. Failures were associated with a high-offset 127° femoral stem neck angle and increased neck lengths; 43.3% (13 of 30) of the observed failures included implant sizes outside the voluntary recall (27.8% [5 of 18] of the GTF and 75.0% [8 of 12] of the taper corrosion cases). Serum cobalt and chromium levels were elevated (cobalt: 8.4 ± 7.0 μg/mL; chromium: 3.4 ± 3.3 μ/L; cobalt/chromium ratio: 3.7). The metal artifact reduction sequence magnetic resonance imaging demonstrated large cystic fluid collections typical with adverse local tissue reactions. During revision, a pseudotumor was observed in all cases. Pathology suggested a chronic inflammatory response. Impending GTF could be diagnosed based on aspiration of black synovial fluid and an oblique femoral head as compared with the neck taper on radiographs. In our series of the recalled LFIT CoCr femoral head, the risk of impending GTF or head-neck taper corrosion should be considered as a potential diagnosis in a painful LFIT femoral head and Accolade titanium-molybdenum-zirconium-iron alloy THA with unknown etiology. Almost half of the failures we observed included sizes outside of the

  20. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait

    NARCIS (Netherlands)

    Ruiter, L. de; Janssen, D.W.; Briscoe, A.; Verdonschot, N.J.

    2017-01-01

    BACKGROUND: Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE

  1. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait

    NARCIS (Netherlands)

    de Ruiter, Lennert; Janssen, Dennis W.; Briscoe, Adam; Verdonschot, Nico

    2017-01-01

    Background Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE tibial

  2. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  3. [Measurements of tibio-femoral contact area after experimental partial and subtotal meniscectomie (author's transl)].

    Science.gov (United States)

    Hehne, H J; Riede, U N; Hauschild, G; Schlageter, M

    1981-02-01

    By means of section material, 24 partial and 58 subtotal meniscectomies were performed and the loss of tibio-femoral contact was evaluated by the Touchier-method planimetrically. In cases of partial resection this loss was 12% only, where as in subtotal resection 46%, where by the remaining contact zones lay in the central-, anyway meniscusfree area. The diagram of the chondral splitting lines showed a maximum of compression here, consecutively the remaining contact zone is reduced to the in earlier times most affected cartilage areas. The result correlates to the appearance of chondromalacies of the central tibial plateau in our own section cases and of postoperative osteoarthritis after subtotal meniscectomies in literature. Subtotal meniscectomies lead to incongruence and increased pressure. a pseudo-regeneration seems not to compensate the meniscus function sufficiently. A result for the clinic one should, when possible, resect menisci only partially.

  4. Complications of fixed infrared emitters in computer-assisted total knee arthroplasties

    Directory of Open Access Journals (Sweden)

    Suárez-Vázquez Abelardo

    2007-07-01

    Full Text Available Abstract Background The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock with percutaneous fixation pins was employed in the remaining 39. Results Technical problems related to the fixing of the trackers appeared in nine cases (2.5%. The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2–7, and 5 minutes in the case of the femoral pin (range: 4–11, although with the new tool it was only three minutes (range 2–4 (p Conclusion The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.

  5. Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty

    DEFF Research Database (Denmark)

    Johanson, Per-Erik; Furnes, Ove; Ivar Havelin, Leif

    2017-01-01

    assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups). Results - The CPE version of the ZCA cup had a risk of revision for any...... for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We...

  6. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

    Science.gov (United States)

    2006-01-01

    The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large

  7. The Relationship between Osteoporosis and Osteoarthritis of the Knee: A Report of 2 Cases with Suspected Osteonecrosis

    Directory of Open Access Journals (Sweden)

    Akira Horikawa

    2014-01-01

    Full Text Available Knee specimens of two osteoporotic patients who underwent unilateral knee arthroplasty for suspected osteonecrosis of the knee were examined histologically. Preoperative findings of magnetic resonance images in both patients were consistent with the diagnosis of osteonecrosis of the medial femoral condyles, although plain X-rays showed minimal degenerative changes. In both patients, preoperative bone mineral densities of the femoral condyle and proximal tibia of the affected side were lower than those of the unaffected side. Pathological examination of the resected femoral condyle and proximal tibia showed almost intact joint cartilage, healing of the collapsed subchondral bone, and significant trabecular bone loss. Histologically, no evidence of osteonecrosis, including empty lacunae of the trabecular bone, was observed. These findings indicated that subchondral bone collapse caused by osteoporosis, but not osteonecrosis, initiated the osteoarthritic change of the affected knee. This report emphasizes that there may be cases of progressive local osteoarthritis caused by fracture of subchondral bone because of osteoporosis.

  8. Bilateral Distal Femoral Flexion Deformity After Total Knee Arthroplasty in a Patient with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Jimmy Chan Chun-Ming

    2013-12-01

    Full Text Available Rheumatoid arthritis is an autoimmune systemic disease with predominant peripheral polyarthritis, often leading to severe joint destruction. This is a case report of an 81-year-old woman with long-standing severe rheumatoid arthritis requiring multiple orthopaedic operations for joint destruction since 2000. These operated joints improved her functional mobility until recently, when she found that her knees were fixed at around 70° of flexion with limited motion. There was chronic progressive flexion deformity of bilateral distal femurs, which was an extremely rare complication of total knee arthroplasty.

  9. Femoral head osteonecrosis: Volumetric MRI assessment and outcome

    International Nuclear Information System (INIS)

    Bassounas, Athanasios E.; Karantanas, Apostolos H.; Fotiadis, Dimitrios I.; Malizos, Konstantinos N.

    2007-01-01

    Effective treatment of femoral head osteonecrosis (FHON) requires early diagnosis and accurate assessment of the disease severity. The ability to predict in the early stages the risk of collapse is important for selecting a joint salvage procedure. The aim of the present study was to evaluate the outcome in patients treated with vascularized fibular grafts in relation to preoperative MR imaging volumetry. We studied 58 patients (87 hips) with FHON. A semi-automated octant-based lesion measurement method, previously described, was performed on the T1-w MR images. The mean time of postoperative follow-up was 7.8 years. Sixty-three hips were successful and 24 failed and converted to total hip arthroplasty within a period of 2-4 years after the initial operation. The rate of failures for hips of male patients was higher than in female patients. The mean lesion size was 28% of the sphere equivalent of the femoral head, 24 ± 12% for the successful hips and 37 ± 9% for the failed (p < 0.001). The most affected octants were antero-supero-medial (58 ± 26%) and postero-supero-medial (54 ± 31%). All but postero-infero-medial and postero-infero-lateral octants, showed statistically significant differences in the lesion size between patients with successful and failed hips. In conclusion, the volumetric analysis of preoperative MRI provides useful information with regard to a successful outcome in patients treated with vascularized fibular grafts

  10. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    Science.gov (United States)

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and

  11. Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study.

    Science.gov (United States)

    Jones, Christopher; Aqil, Adeel; Clarke, Susannah; Cobb, Justin P

    2015-09-01

    Short femoral stems for uncemented total hip arthroplasty have been introduced as a safe alternative to traditional longer stem designs. However, there has been little biomechanical examination of the effects of stem length on complications of surgery. This study aims to examine the effect of femoral stem length on torsional resistance to peri-prosthetic fracture. We tested 16 synthetic and two paired cadaveric femora. Specimens were implanted and then rapidly rotated until fracture to simulate internal rotation on a planted foot, as might occur during stumbling. 3D planning software and custom-printed 3D cutting guides were used to enhance the accuracy and consistency of our stem insertion technique. Synthetic femora implanted with short stems fractured at a significantly higher torque (27.1 vs. 24.2 Nm, p = 0.03) and angle (30.3° vs. 22.3°, p = 0.002) than those implanted with long stems. Fracture patterns of the two groups were different, but showed remarkable consistency within each group. These characteristic fracture patterns were closely replicated in the pair of cadaveric femora. This new short-stemmed press-fit femoral component allows more femoral flexibility and confers a higher resistance to peri-prosthetic fracture from torsional forces than long stems.

  12. The influence of early radiolucent lines appearing on femoral head penetration into HXLPE cemented sockets.

    Science.gov (United States)

    Morita, Daigo; Seki, Taisuke; Higuchi, Yoshitoshi; Takegami, Yasuhiko; Amano, Takafumi; Ishiguro, Naoki

    2018-04-01

    This study investigates differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets both with and without radiolucent lines (RLLs) in the early postoperative phase and at 5 years follow-up. There were 35 patients (37 hips), mean age of 66.8 years, who underwent total hip arthroplasty (THA) using highly HXLPE cemented sockets. They were divided into 2 groups based on postoperative the early appearance of RLLs. Femoral head penetrations on both anteroposterior- and Lauenstein-view radiographs were evaluated, and the mean polyethylene (PE) wear rate was calculated based on femoral head penetrations between 2 and 5 years. Femoral head penetrations in the proximal direction were 0.075 mm and 0.150 mm in the RLL and non-RLL groups at 1 year postoperatively ( p = 0.019). At 5 years measured penetration was 0.107 mm and 0.125 mm in the RLL and non-RLL groups, respectively ( p = 0.320). The mean PE wear rates in anteroposterior-view were 0.008 mm/year and 0.003 mm/year in the RLL and non-RLL groups ( p = 0.390) and those in Lauenstein-view were 0.010 mm/year and 0.005 mm/year, respectively ( p = 0.239). In the RLL group, the PE bedding-in was less compared with those in the non-RLL group. Additionally, the mean PE wear rate in the RLL group tended to be higher than that in the non-RLL group. The distribution of stress loading through the cement may differ according to whether early RLLs appear.

  13. Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners.

    Science.gov (United States)

    Morita, Daigo; Seki, Taisuke; Higuchi, Yoshitoshi; Takegami, Yasuhiko; Ishiguro, Naoki

    2017-12-01

    This study aimed at investigating differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets and uncemented liners during 5 years postoperatively. Ninety-six patients (106 hips) with a mean age of 64.4 (range, 35-83) years underwent total hip arthroplasty using a HXLPE cemented socket or liner and were respectively divided into cemented (35 patients [37 hips]) and uncemented (61 patients [69 hips]) groups. Femoral head penetrations were evaluated on both anteroposterior (AP)-view and Lauenstein-view radiographs, and mean polyethylene (PE) wear rates were calculated based on femoral head penetration from 2 to 5 years. Multivariate analyses were performed to assess risk factors for PE wear. At 5 years postoperatively, the cemented and uncemented groups exhibited proximal direction femoral head penetrations of 0.103 mm and 0.124 mm (P = .226) and anterior direction penetrations of 0.090 mm and 0.151 mm (P = .002), respectively. The corresponding mean PE wear rates were 0.004 mm/y and 0.009 mm/y in the AP-view (P = .286) and 0.005 mm/y and 0.012 mm/y in the Lauenstein-view (P = .168), respectively. Left-side operation and high activity were independent risk factors for PE wear on AP-view. When HXLPE was used, all mean PE wear rates were very low and those of cemented sockets and uncemented liners were very similar. PE particle theory suggests that the occurrence of osteolysis and related aseptic loosening might consequently decrease. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. The usefulness of 3D quantitative analysis with using MRI for measuring osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Park, Youn Soo

    2006-01-01

    We wanted to evaluate the usefulness of MRI 3D quantitative analysis for measuring osteonecrosis of the femoral head in comparison with MRI 2D quantitative analysis and quantitative analysis of the specimen. For 3 months at our hospital, 14 femoral head specimens with osteonecrosis were obtained after total hip arthroplasty. The patients preoperative MRIs were retrospectively reviewed for quantitative analysis of the size of the necrosis. Each necrotic fraction of the femoral head was measured by 2D quantitative analysis with using mid-coronal and mid-sagittal MRIs, and by 3D quantitative analysis with using serial continuous coronal MRIs and 3D reconstruction software. The necrotic fraction of the specimen was physically measured by the fluid displacement method. The necrotic fraction according to MRI 2D or 3D quantitative analysis was compared with that of the specimen by using Spearman's correlation test. On the correlative analysis, the necrotic fraction by MRI 2D quantitative analysis and quantitative analysis of the specimen showed moderate correlation (r = 0.657); on the other hand, the necrotic fraction by MRI 3D quantitative analysis and quantitative analysis of the specimen demonstrated a strong correlation (r = 0.952) (ρ < 0.05). MRI 3D quantitative analysis was more accurate than 2D quantitative analysis using MRI for measuring osteonecrosis of the femoral head. Therefore, it may be useful for predicting the clinical outcome and deciding the proper treatment option

  15. Antibiotic impregnated total femur spacers: a technical tip

    Directory of Open Access Journals (Sweden)

    Colin D. Canham, MD

    2018-03-01

    Full Text Available Simultaneous prosthetic joint infection of ipsilateral hip and knee arthroplasties is often accompanied by significant bone loss and presents a challenging reconstructive problem. Two-stage reconstruction is favored and requires the placement of a total femur spacer, which is not a commercially available device. We describe a surgical technique, reporting on 2 cases in which a customized total femur antibiotic impregnated spacer was created by combining an articulating knee spacer and an articulating hip spacer with a reinforced cement dowel construct connecting the 2 spacers. Custom total femoral spacers are useful in the management of infected femoral megaprostheses and cases with ipsilateral injected hip and knee arthroplasties and severe femoral bone loss. Keywords: total femur spacer, revision arthroplasty, total hip arthroplasty, total knee arthroplasty, prosthetic joint infection

  16. Failure of Emperion modular femoral stem with implant analysis

    Directory of Open Access Journals (Sweden)

    Benjamin M. Stronach, MD, MS

    2016-03-01

    Full Text Available Modularity in total hip arthroplasty provides multiple benefits to the surgeon in restoring the appropriate alignment and position to a previously damaged hip joint. The vast majority of modern implants incorporate modularity into their design with some implants having multiple modular interfaces. There is the potential for failure at modular junctions because of fretting and crevice corrosion in combination with mechanical loading. This case report details the failure of an Emperion (Smith and Nephew, Memphis, TN femoral stem in a 67-year-old male patient 6 years after total hip replacement. Analysis of the implant revealed mechanically assisted crevice corrosion that likely accelerated fatigue crack initiation in the hip stem. The benefits of modularity come with the potential drawback of a combination of fretting and crevice corrosion at the modular junction, which may accelerate fatigue, crack initiation and ultimately reduce the hip longevity.

  17. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head.

    Science.gov (United States)

    Meier, Reinhard; Kraus, Tobias M; Schaeffeler, Christoph; Torka, Sebastian; Schlitter, Anna Melissa; Specht, Katja; Haller, Bernhard; Waldt, Simone; Rechl, Hans; Rummeny, Ernst J; Woertler, Klaus

    2014-09-01

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53% women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51%) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49%) cases were classified as ARCO stage 2. However, in all 37/37 (100%) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. BME on MRI in AVN of femoral head indicates a subchondral fracture. BME in AVN of the femoral head represents ARCO stage 3/4 disease. CT identifies subchondral fractures and femoral head collapse better than MR imaging. This knowledge helps to avoid understaging and to trigger adequate treatment.

  18. Single shot “3-in-1” femoral nerve blockade with 0.25% or 0.375% levobupivacaine provides similar postoperative analgesia for total knee replacement

    OpenAIRE

    APAN, Alpaslan; SARI, Filiz; EKMEKÇİ, Alp Burak

    2010-01-01

    To compare postoperative analgesia provided by single shot "3-in-1" femoral nerve blockade using 0.25% or 0.375% levobupivacaine in preceding with spinal anesthesia for unilateral total knee replacement surgery. Materials and methods: Forty consenting patients undergoing unilateral total knee arthroplasty were included in this prospective randomized study. Spinal anesthesia was achieved with 15 mg plain bupivacaine at the L3-4 or L4-5 interspace. After resolution of the sp...

  19. Effect of zoledronic acid on reducing femoral bone mineral density loss following total hip arthroplasty: A meta-analysis from randomized controlled trails.

    Science.gov (United States)

    Gao, Jian; Gao, Chong; Li, Hui; Wang, Guo-Sheng; Xu, Chang; Ran, Jian

    2017-11-01

    This meta-analysis aimed to assess the efficiency of intravenous administration of zoledronic acid on reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty (THA). A systematic search was performed in Medline (1966-2017.07.31), PubMed (1966-2017.07.31), Embase (1980-2017.07.31), ScienceDirect (1985-2017.07.31) and the Cochrane Library (1966-2017.07.31). Fixed/random effect model was used according to the heterogeneity tested by I 2 statistic. Sensitivity analysis was conducted and publication bias was assessed. Meta-analysis was performed using Stata 11.0 software. Four studies including 185 patients met the inclusion criteria. The present meta-analysis indicated that there were significant differences between groups in terms of periprosthetic bone mineral density in Gruen zone 1 (SMD = 0.752, 95% CI: 0.454 to 1.051, P = 0.000), 2 (SMD = 0.524, 95% CI: 0.230 to 0.819, P = 0.000), 4 (SMD = 0.400, 95% CI: 0.107 to 0.693, P = 0.008), 6 (SMD = 0.893, 95% CI: 0.588 to 1.198, P = 0.000) and 7 (SMD = 0.988, 95% CI: 0.677 to 1.300, P = 0.000). Intravenous administration of zoledronic acid could significantly reduce periprosthetic bone mineral density loss (Gruen zone 1, 2, 4, 6 and 7) after THA. In addition, no severe adverse events were identified. High-quality RCTs with large sample size were still required. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    Science.gov (United States)

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  1. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Takaharu E-mail: yamazaki@image.med.osaka-u.ac.jp; Watanabe, Tetsu; Nakajima, Yoshikazu; Sugamoto, Kazuomi; Tomita, Tetsuya; Maeda, Daisuke; Sahara, Wataru; Yoshikawa, Hideki; Tamura, Shinichi

    2005-01-01

    The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

  2. Measuring the migration of the components and polyethylene wear after total hip arthroplasty: beads and specialised radiographs are not necessary.

    Science.gov (United States)

    Devane, P A; Horne, J G; Foley, G; Stanley, J

    2017-10-01

    This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient's bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA). Models of the patient's acetabular and femoral component obtained from the manufacturer and models of the patient's pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients. Migration of the acetabular and femoral components can be measured with limits of agreement (LOA) of 0.37 mm and 0.33 mm, respectively. Penetration of the femoral head can be measured with LOA of 0.161 mm. The migration of components and polyethylene wear can be measured without needing specialised radiographs. Accurate measurement may allow earlier prediction of failure after THA. Cite this article: Bone Joint J 2017;99-B:1290-7. ©2017 The British Editorial Society of Bone & Joint Surgery.

  3. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral...... and externally by 5° and 10° using plastic wedges. Accuracy of rotation was within +1°. Digital radiographs were obtained at each position. Varus angles were measured using ImageJ, employing two definitions of PFLA. Mean varus angles increased with 10° of either internal or external rotation with both PFLA...... rotation angles. The effect of rotation on varus angle measurements in these femoral specimens contradicts a previous report using CT. The most probable explanation is the difference in femoral positioning: the CT study used a slightly elevated position compared to that in this study, resulting in better...

  4. Treatment of a femoral shaft fracture in a patient with congenital hip disease: a case report

    Directory of Open Access Journals (Sweden)

    Koutsostathis Stefanos D

    2010-07-01

    Full Text Available Abstract Introduction We present a rare case of two concomitant morbidities treated in one operation. To our knowledge, this is the first report of its kind in the literature. Case presentation A 57-year-old Greek woman was admitted to the emergency department having sustained a spiral mid-shaft femoral fracture. She also suffered from an ipsilateral hip congenital dysplasia with ankylosed hip joint due to severe arthritis. She was treated with a total hip arthroplasty using a long stem performing as an intramedullary nail. Conclusion We undertook a complex operative treatment of both co-morbidities in a one stage procedure with a satisfactory clinical result.

  5. Comparison of Hemodynamic Changes during General Anesthesia with Low-dose Isoflurane or Propofol in Elderly Patients Undergoing Upper Femoral Surgery

    Directory of Open Access Journals (Sweden)

    Mir Mohammad Taghi Mortazavi

    2016-01-01

    Full Text Available Background & objectives: Surgery of upper part of femor in elderly patients can be due to the fracture of femoral neck, shaft and arthroplasty. Hemodynamic changes and complications of the anesthesia are among the major concerns. The aim of this study was to compare the hemodynamic changes in low dose isoflurane with propofol in upper femoral surgeries in elderly patients. Methods: This prospective clinical trial study was done on 60 patients over 65 year-old elderly patients with ASA physical status of I and II that were candidate for upper femoral surgery in two groups (inhalational: isoflurane 0.5-0.6 MAC and (total intravenous anesthesia with propofol 50-100 mic/kg/min. Hemodynamic changes were compared in these groups with the same anesthetic depth (HR-SBP-DBP-MBP-SaO₂. Results: There was no significant difference in heart rate, age or sex between two groups. In isoflurane group SBP on 20 and 25th minutes and DBP and MBP on 20, 25 and 35th minutes were significantly higher than propofol group. In propofol group SaO₂ was significantly more than isoflurane group on induction, start of surgery and on 5, 25, 35 and 45th minutes of surgery. Conclusion: In anesthesia with the same Bi-Spectral Index, isoflurane provides more stable hemodynamic parameters than propofol.

  6. Imaging of hip joint arthroplasty; Bildgebung bei Hueftgelenkendoprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C. [Univ.-Klinik fuer Radiodiagnostik, Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Wien (Austria)

    2009-05-15

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [German] Dem Hueftgelenk als groesstem Gelenk des menschlichen Koerpers kommt eine besondere Bedeutung in der muskuloskelettalen Radiologie zu. Entsprechend wichtig ist auch die radiologische Beurteilung von Hueftgelenkendoprothesen, die z. B. infolge degenerativer Gelenkerkrankungen, einer Hueftkopfnekrose oder einer Fraktur eingesetzt werden. Die Projektionsradiographie ist weiterhin die primaere Modalitaet zur Beurteilung von Hueftgelenkendoprothesen, direkt postoperativ und zur laengerfristigen Verlaufskontrolle. Diese Methode erlaubt in der Mehrzahl der Faelle eine suffiziente Antwort auf die Frage nach Lockerung, periprothetischer Fraktur oder Prothesenmaterialbruch, Luxation, Infektion und Weichteilkalzifikation

  7. [Sports participation after joint arthroplasty].

    Science.gov (United States)

    Dauty, M; Letenneur, J

    2007-12-01

    To recommand sports activities after joint arthroplasty from the literature analysis, the French surgeon's opinion and wish patients. From the Medline data base interrogation according to keywords: Sports, Arthroplasty, Athletics, Physical training, two different readers, an orthopedic surgeon and a Physical Medicine and Rehabilitation physician selected articles in French or English language according to the level of proofs of the french classification of the Accreditation and Health Evaluation National Agency (Anaes). Professional practices were estimated by the interrogation of 30 orthopedic surgeons members of the french West Orthopaedics Society (SOO). The demand of sports practice was studied with patients recently operated for a primary total knee arthroplasty (TKA) after gonarthrosis. Twenty-two articles were selected from 305 articles obtained by the search according to keywords. Ten literature reviews are limited by the absence of prospective randomized study. A level II study and eleven level IV articles are reported. According to the subjective orthropedic surgeon's opinion, the objective results based on the joint load studied and the percentage of arthroplasty revision, sport is beneficial for the individual health but perhaps not for the arthroplasty survey. However, aerobic and leisure activities are recommended (walking, swimming, cycling) in agreement with the demand of the patients recently operated with a TKA. TKA differs from Total Hip Arthroplasty for jogging because of knee joint constraints during the knee flexion. A single study reports sports possibilities after shoulder arthroplasty and ankle arthroplasty and no study reports results after elbow arthroplasty.

  8. Patient - implant dimension mismatch in total knee arthroplasty: Is it worth worrying? An Indian scenario

    Directory of Open Access Journals (Sweden)

    Jai Thilak

    2016-01-01

    Full Text Available Background: The correct sizing of the components in both anteroposterior and mediolateral (ML dimensions is crucial for the success of a total knee arthroplasty (TKA. The size of the implants selected is based on the intraoperative measurements. The currently used TKA implants available to us are based on morphometric measurements obtained from a Western/Caucasian population. Hence, the risk of component ML mismatch is more common in Asian sub-population, as they are of a smaller built and stature. This study aims to look into the following aspects agnitude of the ML mismatch between the femoral component and the patient′s anatomical dimension, evaluation of gender variations in distal femur dimensions, and gender-wise and implant-wise correlation of ML mismatch. Materials and Methods: Intraoperatively, the distal femoral dimensions were measured using sterile calipers after removing the osteophytes and compared with the ML dimension of the implant used. ML mismatch length thus obtained is correlated with the various parameters. Results: Males showed larger distal femoral dimensions when compared to females. Males had larger ML mismatch. None of the implants used perfectly matched the patient′s anatomical dimensions. Patients with larger mismatch had lower scorings at 2 years postoperative followup. Conclusion: Implant manufacturers need to design more options of femoral implants for a better fit in our subset of patients. The exact magnitude of mismatch which can cause functional implications need to be made out. The mismatch being one of the important factors for the success of the surgery, we should focus more on this aspect.

  9. Dual mobility total hip arthroplasty in hemiplegic patients

    Directory of Open Access Journals (Sweden)

    Henawy Ayman T.

    2017-01-01

    Full Text Available Introduction: The rate of cerebrovascular insults is increasing, currently leaving many patients with difficulties to maintain their balance due to muscular weakness and/or poor central control. Those patients are at risk of dislocation when total hip arthroplasty (THA is planned. Instability remains the most significant issue after primary THA especially in such groups of patients. The risk is more pronounced when other factors are added such as, older age, femoral neck fractures, avascular necrosis and/or hip osteoarthritis. Dual mobility cup (DMC is considered as a prosthesis with higher inherent stability that may help in such situation. In this patient series, we aimed to evaluate stability, clinical and radiological results of dual mobility THA done on the weak limb of hemiplegic patients. Methods: Twenty-four consecutive hemiplegic patients have undergone DMC with a mean age of 68 years. The indication for surgery was hip osteoarthritis in one third of the patients and femoral neck fractures in the remaining patients. Those patients were capable of walking prior to hospital admission despite weakness. Those patients were observed postoperatively for at least one year. Clinical results and complications were recorded. Results: After a minimum of one year, 91.6% of the patients have satisfactory results. No cases of hip or intraprosthetic dislocation were observed. Discussion: Dual mobility THA in the hemiplegic patients provides both efficacy and stability with good functional results.

  10. OUTCOMES OF PALLIATIVE ORTHOPEDIC SURGERY FOR HIP DISLOCATION IN PATIENTS WITH CEREBRAL PALSY

    Directory of Open Access Journals (Sweden)

    R. R. Bidyamshin

    2016-01-01

    Full Text Available Introduction. Hip dislocation is the key problem in patients with severe cerebral palsy (GMFCS IV, V older than 10 years that affects life quality and limits functional capabilities. In the present study the authors evaluated the efficiency of the proximal femoral resection arthroplasty (pfra and valgus proximal osteotomy of the femur (VPOF associated with femoral head resection for pain control, improvement of postural management, hygiene and verticalization with total weight-bearing and correction of accompanying orthopaedic deformities. Material and мethods. A retrospective study compared two groups of patients where PFRA (7 cases, 13 hips or VPOF (14 patients, 23 hips were performed. Level V of GMFCS was reported in 10 patients, and level IV of GMFCS – in 11 patients. The mean age at time of surgery was 15.3±3.9 y.o. PFRA was performed in 7 cases (13 joints and VPOF – in 14 patients (23 joints. Results. The authors did not observe any difference between the methods in respect of pain control, postural management, comfortable sitting position and hygiene. The verticalization with total weight-bearing and life quality improvement was achieved only after PVOF with femoral head resection associated with simultaneous knee and foot deformity correction performed according to the principles of Single-Event Multilevel Orthopedic Surgery. Conclusion. Both palliative methods allow to control pain syndrome, to achieve satisfactory postural management, comfortable sitting position and hygiene. But only VPOF with simultaneous knee and foot deformity correction provides possibility to verticalize the patient with weight-bearing using different orthopedic devices.

  11. Unicompartmental knee arthroplasty

    NARCIS (Netherlands)

    Kort, Nanne Pieter

    2007-01-01

    This thesis concerns technical aspects of unicompartmental knee arthroplasty. Recent years have witnessed a resurgence of interest in unicompartmental arthroplasty, particularly with the introduction of the minimally invasive technique. In the light of the excellent long-term results of the total

  12. Relationships between post operative pain management and short term functional mobility in total knee arthroplasty patients with a femoral nerve catheter: A preliminary study

    Directory of Open Access Journals (Sweden)

    Ward Sarah

    2011-02-01

    Full Text Available Abstract Background Effective pain management following total knee arthroplasty (TKA is fundamental in achieving positive rehabilitation outcomes. The purpose of our study was to investigate post operative pain management in relation to short term functional mobility in an intervention group receiving concomitant use of an IV narcotic PCA and a continuous infusion of local anaesthetic via a femoral nerve catheter (CFNC, compared to a group receiving narcotic PCA alone. This was a preliminary study conducted to establish an appropriate design for a larger investigative study. Methods A prospective design was used to measure the effect of a CFNC on post operative pain management and functional mobility prior to hospital discharge. The amount of fentanyl used, pain and nausea scores, timed up and go (TUG tests and active range of knee movement (AROM were used to compare a CFNC and supplemental narcotic patient controlled analgesia (PCA group (n = 27 with a PCA only group (n = 25. Results The CFNC group used significantly less fentanyl than the PCA only group (p s = .505 p s = .529 p s = .328, p = .034 Conclusions In this small preliminary study improved TUG performance at Day 4 post op was not influenced by the use of a CFNC but was positively correlated with male gender, preoperative performance, time elapsed since last oral analgesia and pain score. However AROM was decreased in the CFNC group suggesting further research on the relationship between CFNCs, local anaesthetic concentration and quadriceps strength should be incorporated in the follow up study's design.

  13. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty

    International Nuclear Information System (INIS)

    White, S.P.; Blom, A.W.; Lee, M.; Smith, E.J.

    2005-01-01

    To study whether there was a common pattern of clinical symptoms, signs and radiographic features for the dissociation of the polyethylene liner from an acetabular component and to postulate reasons for these features. Retrospective study of notes and radiographs of cases of revision hip arthroplasty for polyethylene liner dissociation of the cementless Harris-Galante I porous-coated acetabular component (Zimmer Inc, Warsaw, IN) at the Avon Orthopaedic Centre, Bristol, UK and St. Mary's Hospital, Bristol, UK between 1995 and 2004. Patients were contacted to confirm preoperative symptoms. Nine cases of late polyethylene liner dissociation of this prosthesis have been revised in these institutions. All patients presented with a reduction in mobility, groin pain and limp. Eight patients reported an audible noise on hip movement. In all cases, radiographs showed radiolucency medial to the femoral neck in association with an eccentrically placed femoral head showing contact with the acetabular metal shell, which we have termed the ''crescent sign.'' There is a typical clinical presentation in this study. The diagnosis can be made from a single anteroposterior pelvic radiograph without the need for previous films for comparison, or the need for arthrography. Clinicians should look specifically for the crescent sign when an eccentrically placed femoral head has been noted, in order to differentiate the more unusual diagnosis of dissociation from that of polyethylene wear. Early revision surgery can prevent damage to the femoral head and metal acetabular shell, thus reducing the complexity of revision surgery. (orig.)

  14. Removal of well-fixed components in femoral revision arthroplasty with controlled segmentation of the proximal femur.

    Science.gov (United States)

    Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis

    2014-12-31

    The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.

  15. Effects of total knee arthroplasty on ankle alignment in patients with varus gonarthrosis: Do we sacrifice ankle to the knee?

    Science.gov (United States)

    Gursu, Sarper; Sofu, Hakan; Verdonk, Peter; Sahin, Vedat

    2016-08-01

    Total knee arthroplasty is one of the most commonly preferred surgical methods in the treatment of patients with varus gonarthrosis. In this study, we aimed to evaluate the radiological changes observed in the ankles after total knee arthroplasty. Between May 2012 and June 2013, 80 knees of 78 patients with varus deformity over 10° underwent total knee arthroplasty. For each patient, full-leg standing radiographs were obtained pre- and post-operatively. Mechanical and anatomical axes (HKA and AA), lateral distal femoral angle, medial proximal tibial angle, lateral distal tibial angle (LDTA), ankle joint line orientation angle (AJOA), tibial plafond talus angle (PTA) and talar shift were measured for each patient both pre- and post-operatively. Pre-operatively, the mean HKA was 16.6° and the mean AA was 10.41°, both in favour of varus alignment. Post-operatively, the mean HKA decreased to 3.6° and the mean AA to -2.1. The mean LDTA was 87.3°. Before the operation, the mean AJOA was -7.6°, opening to the medial aspect of the ankle, and it was 0.04° after the operation and opening to the lateral aspect (p < 0.05). Our study reveals the changes occurring in the ankle after acute correction of long-standing varus deformity of the knee using total knee arthroplasty. In cases undergoing knee arthroplasty, effect of the acute change in the alignment of the knee on the ankle should be taken into consideration and the amount of correction should be calculated carefully in order not to damage the alignment of the ankle. IV.

  16. A new topical hemostatic agent TT-173 reduces blood loss in a sheep model of total knee arthroplasty.

    Science.gov (United States)

    Centeno, Alberto; Rojas, Santiago; Arias, Belén; Miquel, Ignasi; Sánchez, Pilar; Ureta, Claudia; Rincón, Esther; López, Ramón; Murat, Jesús

    2017-12-01

    Total knee arthroplasty is associated with blood loss during the intervention and may require allogenic blood transfusion. Treatments such as tranexamic acid and fibrin sealants improved the bleeding control in several clinical trials, but the hemorrhage associated with the intervention is still significant. Thus far, very few studies have evaluated hemostatic treatments in animal models of total knee arthroplasty. This work describes a sheep model of bleeding associated with total knee arthroplasty and investigates a new class of hemostatic treatment based on recombinant tissue factor. Sheep were treated with the anticoagulant heparin, and the joint was accessed by a paramedial incision. Ligaments and menisci were eliminated and femoral condyles and tibia plateau were sectioned exposing the trabecular bone. An intra-articular drain was used to recover and quantify the blood loss during the 90-min period after treatment. The efficacy of one milligram and three milligrams of TT-173 was evaluated and compared with tranexamic acid. The occurrence of analytical alterations and systemic absorption was also investigated. Treatment with TT-173 reduced the blood loss in comparison with control or tranexamic acid. No significant differences were observed between the two doses evaluated. Moreover, a dose of six milligrams of TT-173 did not induce any clinical or analytical alteration, and significant systemic absorption was not observed. Data obtained strongly suggest that TT-173 could be useful in reducing the blood loss associated with total knee arthroplasty and without safety concerns derived from the systemic absorption of the product. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Treatment of periprosthetic femoral fractures of the knee.

    Science.gov (United States)

    Ehlinger, Matthieu; Adam, Philippe; Abane, Lamine; Rahme, Michel; Moor, Beat Kaspar; Arlettaz, Yvan; Bonnomet, François

    2011-09-01

    We report a continuous series of periprosthetic femoral fractures after knee arthroplasty treated with a locking plate. We hypothesize that minimally invasive surgery and immediate weight-bearing improve functional recovery. From June 2002 to December 2008, 15 patients with 16 fractures were treated. Median age was 81 years. The autonomy level according to the mobility score of Parker and Palmer showed a median of 5 (0-9). Osteosynthesis was performed mainly through a minimally invasive approach using a locking compression plate. The rehabilitation protocol consisted of immediate mobilization and, whenever possible, immediate unrestricted weight-bearing. Five patients died during follow-up, more than 1 year after osteosynthesis. Their results were included. Autonomy and mobility were preserved with a median postoperative score of 4 (0-9) according to Parker and Palmer. The consolidation rate was 93.8%, which was obtained within 10 weeks. There were no mechanical or infectious complications. Fourteen cases were treated with minimally invasive surgery without fracture exposition; the remaining 2 required a slightly more extended approach. Full weight-bearing occurred 10 times; 20-kg partial weight-bearing was advised twice; and on 4 occasions, no weight-bearing was allowed for 6 weeks. Osteosynthesis with a minimally invasive bridge-plating technique is effective in the treatment of periprosthetic, distal femoral fractures without component loosening. Immediate full weight-bearing is possible if certain rules are respected. The surgical management presented herein is beneficial for these challenging fractures, and it may help reduce the complication rate and improve functional outcome.

  18. Co-expression of DKK-1 and Sclerostin in Subchondral Bone of the Proximal Femoral Heads from Osteoarthritic Hips.

    Science.gov (United States)

    Zarei, Allahdad; Hulley, Philippa A; Sabokbar, Afsie; Javaid, M Kassim

    2017-06-01

    Osteoarthritis (OA) is a progressively degenerative joint disease influenced by structural and metabolic factors. There is growing evidence that subchondral bone is involved in both symptomatic and structural progression in OA. The Wnt pathway has been implicated in the progression of OA but the expression and function of the Wnt inhibitors, Dikkopf (DKK-1) and sclerostin (SOST), are unclear. We examined the regional distribution of DKK-1 and SOST in subchondral bone of the femoral head using resection specimens following arthroplasty in patients presenting with end-stage OA. Cylindrical cores for immunohistochemistry were taken through midpoint of full thickness cartilage defect, partial cartilage defect, through base of osteophyte and through macroscopically normal cartilage. Subchondral bone was thickest in cores taken from regions with full cartilage defect and thinnest in cores taken from osteophyte regions. In subchondral bone, expression of both DKK-1 and SOST was observed exclusively in osteocytes. Expression was highest in subchondral bone in cores taken from regions with partial but not full thickness cartilage defects. DKK-1 but not SOST was expressed by chondrocytes in cores with macroscopically normal cartilage. The current study describes the regional cellular distribution of SOST and DKK-1 in hip OA. Expression was highest in the osteocytes in bone underlying partial thickness cartilage defects. It is however not clear if this is a cause or a consequence of alterations in the overlying cartilage. However, it is suggestive of an active remodeling process which might be targeted by disease-modifying agents.

  19. Reverse-total shoulder arthroplasty cost-effectiveness: A quality-adjusted life years comparison with total hip arthroplasty.

    Science.gov (United States)

    Bachman, Daniel; Nyland, John; Krupp, Ryan

    2016-02-18

    To compare reverse-total shoulder arthroplasty (RSA) cost-effectiveness with total hip arthroplasty cost-effectiveness. This study used a stochastic model and decision-making algorithm to compare the cost-effectiveness of RSA and total hip arthroplasty. Fifteen patients underwent pre-operative, and 3, 6, and 12 mo post-operative clinical examinations and Short Form-36 Health Survey completion. Short form-36 Health Survey subscale scores were converted to EuroQual Group Five Dimension Health Outcome scores and compared with historical data from age-matched patients who had undergone total hip arthroplasty. Quality-adjusted life year (QALY) improvements based on life expectancies were calculated. The cost/QALY was $3900 for total hip arthroplasty and $11100 for RSA. After adjusting the model to only include shoulder-specific physical function subscale items, the RSA QALY improved to 2.8 years, and its cost/QALY decreased to $8100. Based on industry accepted standards, cost/QALY estimates supported both RSA and total hip arthroplasty cost-effectiveness. Although total hip arthroplasty remains the quality of life improvement "gold standard" among arthroplasty procedures, cost/QALY estimates identified in this study support the growing use of RSA to improve patient quality of life.

  20. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    Science.gov (United States)

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  1. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Reinhard; Schaeffeler, Christoph; Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Kraus, Tobias M. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany); Berufsgenossenschaftliche Unfallklinik Tuebingen, Department of Trauma and Orthopaedics, Tuebingen (Germany); Torka, Sebastian [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany); Berufsgenossenschaftliche Unfallklinik Murnau, Department of Trauma and Orthopaedics, Murnau (Germany); Schlitter, Anna Melissa; Specht, Katja [Klinikum rechts der Isar, Technische Universitaet Muenchen, Institute of Pathology, Munich (Germany); Haller, Bernhard [Klinikum rechts der Isar, Technische Universitaet Muenchen, Institute of Medical Statistics and Epidemiology, Munich (Germany); Rechl, Hans [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Orthopaedics, Munich (Germany)

    2014-09-15

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53 % women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51 %) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49 %) cases were classified as ARCO stage 2. However, in all 37/37 (100 %) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P < 0.05). Histopathological analysis confirmed bone necrosis and subchondral fractures. In patients with AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. circle BME on MRI in AVN of femoral head indicates a subchondral fracture. (orig.)

  2. Bone marrow oedema on MR imaging indicates ARCO stage 3 disease in patients with AVN of the femoral head

    International Nuclear Information System (INIS)

    Meier, Reinhard; Schaeffeler, Christoph; Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus; Kraus, Tobias M.; Torka, Sebastian; Schlitter, Anna Melissa; Specht, Katja; Haller, Bernhard; Rechl, Hans

    2014-01-01

    To test the hypothesis that bone marrow oedema (BME) observed on MRI in patients with avascular necrosis (AVN) of the femoral head represents an indicator of subchondral fracture. Thirty-seven symptomatic hips of 27 consecutive patients (53 % women, mean age 49.2) with AVN of the femoral head and associated BME on magnetic resonance (MR) imaging were included. MR findings were correlated with computed tomography (CT) of the hip and confirmed by histopathological examination of the resected femoral head. Imaging studies were analysed by two radiologists with use of the ARCO classification. On MR imaging a fracture line could be identified in 19/37 (51 %) cases, which were classified as ARCO stage 3 (n = 15) and stage 4 (n = 4). The remaining 18/37 (49 %) cases were classified as ARCO stage 2. However, in all 37/37 (100 %) cases a subchondral fracture was identified on CT, indicating ARCO stage 3/4 disease. The extent of subchondral fractures and the femoral head collapse was graded higher on CT as compared to MRI (P < 0.05). Histopathological analysis confirmed bone necrosis and subchondral fractures. In patients with AVN, BME of the femoral head represents a secondary sign of subchondral fracture and thus indicates ARCO stage 3 disease. circle BME on MRI in AVN of femoral head indicates a subchondral fracture. (orig.)

  3. Oxidized zirconium versus cobalt-chromium against the native patella in total knee arthroplasty: Patellofemoral outcomes.

    Science.gov (United States)

    Matassi, Fabrizio; Paoli, Tommaso; Civinini, Roberto; Carulli, Christian; Innocenti, Massimo

    2017-10-01

    Oxidized zirconium (OxZr) has demonstrated excellent mechanical properties in vitro when used against articular cartilage; less coefficient of friction and less chondral damage have been found when compared with cobalt-chromium (CoCr) implants. However, controversy exists as to whether implants with a zirconium femoral component articulate safely with a native patella in total knee arthroplasty (TKA). To answer this question, the clinical and radiographic results were analysed from a group of patients who underwent a TKA with patella retention; the OxZr versus CoCr femoral components were compared. The present study prospectively evaluated 83 knees of 74 patients from 2009 to 2010. Each patient was evaluated clinically (visual analogue scale, Knee Society score, patellar score) and radiographically (long leg standing radiograph, anterior-posterior and latero-lateral projections, axial view of the patella) pre-operatively and postoperatively with a mean follow-up of 4.47years. The patellar tilt and shift, and progression of patellofemoral osteoarthritis were calculated with the axial view. There were no patient reported adverse reactions and none of the evaluated prostheses failed. Both the clinical and radiographic evaluations showed no statistically significant between-group differences. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component associated with patellar retention in TKA. Published by Elsevier B.V.

  4. Availability of Additional Mediolateral Implant Option During Total Knee Arthroplasty Improves Femoral Component Fit Across Ethnicities

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma, MS(Orth

    2017-06-01

    Conclusions:. The shape of the distal part of the femur varies not only among ethnicities but also within ethnic groups, leading to a high prevalence of overhang when only standard prostheses are available. The additional availability of a femoral component with a reduced mediolateral dimension for the same anteroposterior size can reduce overhang and improve component fit across ethnicities.

  5. The Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Varnum, Claus; Pedersen, Alma Becic

    2016-01-01

    AIM OF DATABASE: The aim of the Danish Hip Arthroplasty Register (DHR) is to continuously monitor and improve the quality of treatment of primary and revision total hip arthroplasty (THA) in Denmark. STUDY POPULATION: The DHR is a Danish nationwide arthroplasty register established in January 1995...

  6. Early Rehabilitation in Elderly after Arthroplasty versus Internal Fixation for Unstable Intertrochanteric Fractures of Femur: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Yoo, Jun Il; Ha, Yong Chan; Lim, Jae Young; Kang, Hyun; Yoon, Byung Ho; Kim, Hyunho

    2017-05-01

    The purpose of this study was to compare the outcomes focusing on the functional outcome and clinical results of replacement arthroplasty (AP) vs. internal fixation (IF) for the treatment of unstable intertrochanteric femoral fracture in elderly. Systematic review and meta-analysis were performed on 10 available clinical studies (2 randomized controlled trials and 8 comparative studies). Subgroup analysis was performed by type of methodological quality. Partial weight bearing time in AP group was earlier than that in IF group (SMD = -0.86; 95% CI = -0.42, 1.29; P = 0.050). The overall outcomes such as mortality, reoperation rate, and complication showed no significant diffrence between the 2 groups (AP vs. IF). Therefore, this systematic review demonstrates that AP provides superior functional outcomes especially earlier mobilization, as compared to IF in elderly patients with an unstable intertrochanteric femoral fracture. © 2017 The Korean Academy of Medical Sciences.

  7. Reoperations following proximal interphalangeal joint nonconstrained arthroplasties.

    Science.gov (United States)

    Pritsch, Tamir; Rizzo, Marco

    2011-09-01

    To retrospectively analyze the reasons for reoperations following primary nonconstrained proximal interphalangeal (PIP) joint arthroplasty and review clinical outcomes in this group of patients with 1 or more reoperations. Between 2001 and 2009, 294 nonconstrained (203 pyrocarbon and 91 metal-plastic) PIP joint replacements were performed in our institution. A total of 76 fingers (59 patients) required reoperation (50 pyrocarbon and 26 metal-plastic). There were 40 women and 19 men with an average age of 51 years (range, 19-83 y). Primary diagnoses included osteoarthritis in 35, posttraumatic arthritis in 24, and inflammatory arthritis in 17 patients. There were 21 index, 27 middle, 18 ring, and 10 small fingers. The average number of reoperations per PIP joint was 1.6 (range, 1-4). A total of 45 joints had 1 reoperation, 19 had 2, 11 had 3, and 1 had 4. Extensor mechanism dysfunction was the most common reason for reoperation; it involved 51 of 76 fingers and was associated with Chamay or tendon-reflecting surgical approaches. Additional etiologies included component loosening in 17, collateral ligament failure in 10, and volar plate contracture in 8 cases. Inflammatory arthritis was associated with collateral ligament failure. Six fingers were eventually amputated, 9 had PIP joint arthrodeses, and 2 had resection arthroplasties. The arthrodesis and amputation rates correlated with the increased number of reoperations per finger. Clinically, most patients had no or mild pain at the most recent follow-up, and the PIP joint range-of-motion was not significantly different from preoperative values. Pain levels improved with longer follow-up. Reoperations following primary nonconstrained PIP joint arthroplasties are common. Extensor mechanism dysfunction was the most common reason for reoperation. The average reoperation rate was 1.6, and arthrodesis and amputation are associated with an increasing number of operations. Overall clinical outcomes demonstrated no

  8. [Early results of proximal femoral fractures treated with FENIX modular hemiarthroplasty].

    Science.gov (United States)

    Görski, Radosław; Górecki, Andrzej; Olszewski, Paweł; Biedrzycki, Jerzy; Skowronek, Paweł

    2010-01-01

    The article discusses preliminary clinical results in patients with proximal femoral fractures treated with hemiarthroplasty using a FENIX implant. The study group comprised 41 subjects aged 69 to 97 (median age 82.3 year). The follow-up study provided data on 26 subjects (63.4%), among which 15 attended the check-up, 5 subjects refused to visit at the Department and 6 subjects were reported as deceased. Median follow-up period amounted to 6.8 month (1 to 22 months). General hospitalization-related complications occurred in 8 patients (19.5%). During hospitalization no deaths occurred, in the deceased group 3 patients died within 12 months after surgery, while another 3 died after the twelve-month postoperative period (median of 13.3%). According to Merle d'Aubigne-Postel score favorable long-term results were observed in 9 patients (59.9%), 13 patients regained the level of motor function similar to the functional ability prior to fracture. The need to postpone the surgery due to general health status and impaired pre-operative motor function are significant negative prognostic factors. The results obtained were compared with previous efficacy studies on femoral fracture treatment using an Austin-Moore implant. Functional ability and self-reliance was higher in the FENIX group. FENIX arthroplasty effectively helps patients regain self-reliance and motor function thanks to its modular characteristics and anatmoical construction.

  9. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  10. Intraoperative joint gaps and mediolateral balance affect postoperative knee kinematics in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Muneta, Takeshi; Sekiya, Ichiro; Banks, Scott A

    2015-12-01

    Adjusting joint gaps and establishing mediolateral (ML) soft tissue balance are considered essential interventions for better outcomes in total knee arthroplasty (TKA). However, the relationship between intraoperative laxity measurements and weightbearing knee kinematics has not been well explored. This study aimed to quantify the effect of intraoperative joint gaps and ML soft tissue balance on postoperative knee kinematics in posterior-stabilized (PS)-TKA. We investigated 44 knees in 34 patients who underwent primary PS-TKA by a single surgeon. The central joint gaps and ML tilting angles at 0°, 10°, 30°, 60°, 90°, 120° and 135° flexion were measured during surgery. At a minimum of two year follow-up, we analyzed in vivo kinematics of these knees and examined the influence of intraoperative measurements on postoperative kinematics. Gap difference of knee flexion at 135° minus 0° was correlated with the total posterior translation of lateral femoral condyle (r=0.336, p=0.042) and femoral external rotation (r=0.488, p=0.002) during squatting, anteroposterior position of lateral femoral condyle (r=-0.510, p=0.001) and maximum knee flexion (r=0.355, p=0.031) in kneeling. Similar correlations were observed between deep flexion gap differences with respect to the 90° reference and postoperative knee kinematics. Well-balanced knees showed less anterior translation of medial femoral condyle in mid- to deep flexion, consistent femoral external rotation, and the most neutral valgus/varus rotation compared with unbalanced knees. These findings indicate the importance of adequate intraoperative joint gaps in deep flexion and ML soft tissue balance throughout the range of motion. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Lumbar spine degenerative disease : effect on bone mineral density measurements in the lumbar spine and femoral neck

    International Nuclear Information System (INIS)

    Juhng, Seon Kwan; Koplyay, Peter; Jeffrey Carr, J.; Lenchik, Leon

    2001-01-01

    To determine the effect of degenerative disease of the lumbar spine on bone mineral density in the lumbar spine and femoral neck. We reviewed radiographs and dual energy x-ray absorptiometry scans of the lumbar spine and hip in 305 Caucasian women with suspected osteoporosis. One hundred and eight-six patient remained after excluding women less than 40 years of age (n=18) and those with hip osteoarthritis, scoliosis, lumbar spine fractures, lumbar spinal instrumentation, hip arthroplasty, metabolic bone disease other than osteoporosis, or medications known to influence bone metabolism (n=101). On the basis of lumbar spine radiographs, those with absent/mild degenerative disease were assigned to the control group and those with moderate/severe degenerative disease to the degenerative group. Spine radiographs were evaluated for degenerative disease by two radiologists working independently; discrepant evaluations were resolved by consensus. Lumbar spine and femoral neck bone mineral density was compared between the two groups. Forty-five (24%) of 186 women were assigned to the degenerative group and 141 (76%) to the control group. IN the degenerative group, mean bone mineral density measured 1.075g/cm? in the spine and 0.788g/cm 2 in the femoral neck, while for controls the corresponding figures were 0.989g/cm 2 and 0.765g/cm 2 . Adjusted for age, weight and height by means of analysis of variance, degenerative disease of the lumbar spine was a significant predictor of increased bone mineral density in the spine (p=0.0001) and femoral neck (p=0.0287). Our results indicate a positive relationship between degenerative disease of the lumbar spine and bone mineral density in the lumbar spine and femoral neck, and suggest that degenerative disease in that region, which leads to an intrinsic increase in bone mineral density in the femoral neck, may be a good negative predictor of osteoporotic hip fractures

  12. Increased Dickkopf-1 expression accelerates bone cell apoptosis in femoral head osteonecrosis.

    Science.gov (United States)

    Ko, Jih-Yang; Wang, Feng-Sheng; Wang, Ching-Jen; Wong, To; Chou, Wen-Yi; Tseng, Shin-Ling

    2010-03-01

    Intensive bone cell apoptosis contributes to osteonecrosis of femoral head (ONFH). Dickkopf-1 (DKK1) reportedly mediates various types of skeletal disorders. This study investigated whether DKK1 was linked to the occurrence of ONFH. Thirty-nine patients with various stages of ONFH were recruited. Bone specimens were harvested from 34 ONFH patients underwent hip arthroplasty, and from 10 femoral neck fracture patients. Bad, Bcl2 TNFalpha, DKK1, Wnt3a, LRP5, and Axin1 expressions were analyzed by quantitative RT-PCR and ELISA. Apoptotic cells were assayed using terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate-biotin nick end-labelling (TUNEL). Primary bone-marrow mesenchymal cells were treated with DKK1 RNA interference and recombinant DKK1 protein. ONFH patients with the histories of being administrated corticosteroids and excessive alcohol consumption had significantly higher Bad and DKK1 mRNA expressions in bone tissue and DKK1 abundances in serum than femoral neck fracture patients. Bone cells adjacent to osteonecrotic bone displayed strong DKK1 immunoreactivity and TUNEL staining. Increased DKK1 expression in bone tissue and serum correlated with Bad expression and TUNEL staining. Serum DKK1 abundance correlated with the severity of ONFH. The DKK1 RNA interference and recombinant DKK1 protein regulated Bad expression and apoptosis of primary bone-marrow mesenchymal cells. Knock down of DKK1 reduced dexamethasone-induced apoptosis of mesenchymal cells. Taken together, promoted DKK1 expression was associated with bone cell apoptosis in the occurrence of ONFH patients with the histories of corticosteroid and alcohol intake and progression of ONFH. DKK1 expression in injured tissue provides new insight into ONFH pathogenesis.

  13. Staged lengthening arthroplasty for pediatric osteosarcoma around the knee.

    Science.gov (United States)

    Kong, Chang-Bae; Lee, Soo-Yong; Jeon, Dae-Geun

    2010-06-01

    Orthopaedic oncologists often must address leg-length discrepancy after resection of tumors in growing patients with osteosarcoma. There are various alternatives to address this problem. We describe a three-stage procedure: (1) temporary arthrodesis, (2) lengthening by Ilizarov apparatus, and (3) tumor prosthesis. We asked (1) to what extent are affected limbs actually lengthened; (2) how many of the patients who undergo a lengthening procedure eventually achieve joint arthroplasty; and (3) can the three-stage procedure give patients a functioning joint with equalization of limb length? We reviewed 56 patients (younger than 14 years) with osteosarcoma who had staged lengthening arthroplasty between 1991 and 2004. Thirty-five of the 56 patients (63%) underwent soft tissue lengthening, and of these 35, 28 (50% of the original group of 56) had implantation of a mobile joint. Three of the 28 prostheses were later removed owing to infection after arthroplasty. The overall average length gained was 7.8 cm (range, 4-14 cm), and 25 (71%) of the 35 patients had a mobile joint at final followup. The average Musculoskeletal Tumor Society functional score was 23.2 (range, 15-28) and limb-length discrepancy at final followup was 2.6 cm (range, 0-6.5 cm). Although most mobile joints had an acceptable ROM (average, 74.2 degrees ; range, 35 degrees -110 degrees ), extension lag was frequent. Our approach is one option for skeletally immature patients, especially in situations where an expandable prosthesis is not available. However, this technique requires multiple stages and would be inappropriate for patients who cannot accept prolonged functional deficit owing to a limited lifespan or other reasons. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  14. The Warwick patellofemoral arthroplasty trial: a randomised clinical trial of total knee arthroplasty versus patellofemoral arthroplasty in patients with severe arthritis of the patellofemoral joint

    Directory of Open Access Journals (Sweden)

    Odumenya Michelle

    2011-11-01

    Full Text Available Abstract Background Severe arthritis of the knee is a disabling condition, with over 50,000 knee replacements performed each year in the UK. Isolated patellofemoral joint arthritis occurs in over 10% of these patients with the treatment options being patellofemoral arthroplasty or total knee arthroplasty. Whilst many surgeons believe total knee arthroplasty is the 'gold standard' treatment for severe knee arthritis, patellofemoral arthroplasty has certain potential advantages. Primarily, because this operation allows the patient to keep the majority of their own knee joint; preserving bone-stock and the patients' own ligaments. Patellofemoral arthroplasty has also been recognised as a less 'invasive' operation than primary total knee arthroplasty, facilitating a more rapid recovery. There are currently no published results of randomised clinical trials comparing the two arthroplasty techniques. The primary objective of the current study is to assess whether there is a difference in functional knee scores and quality of life outcome assessments at one year post-operation between patellofemoral arthroplasty and total knee arthroplasty. The secondary objective is to assess the complication rates for both procedures. Methods/design Patients who are deemed suitable, by an Orthopaedic Consultant, for patellofemoral arthroplasty and medically fit for surgery are eligible to take part in this trial. The consenting patients will be randomised in a 1:1 allocation to a total knee or patellofemoral arthroplasty. The randomisation sequence will be computer generated and administered by a central independent randomisation service. Following consent, all participants will have their knee function, quality of life and physical activity level assessed through questionnaires. The assigned surgery will then be performed using the preferred technique and implant of the operating surgeon. The first post-operative assessments will take place at six weeks, followed by

  15. Displays mounted on cutting blocks reduce the learning curve in navigated total knee arthroplasty.

    Science.gov (United States)

    Schnurr, Christoph; Eysel, Peer; König, Dietmar Pierre

    2011-01-01

    The use of computer navigation in total knee arthroplasty (TKA) improves the implant alignment but increases the operation time. Studies have shown that the operation time is further prolonged due to the surgeon's learning curve, and longer operation times have been associated with higher morbidity risks. It has been our hypothesis that an improvement in the human-machine interface might reduce the time required during the learning curve. Accordingly, we asked whether the use of navigation devices with a display fixed on the surgical instruments would reduce the operation time in navigated TKAs performed by navigation beginners. Thirty medical students were randomized and used two navigation devices in rotation: these were the Kolibri® device with an external display and the Dash® device with a display that was fixed on the cutting blocks. The time for adjustment of the tibial and femoral cutting blocks on knee models while using these devices was measured. A significant time reduction was demonstration when the Dash® device was used: The time reduction was 21% for the tibial block (p = 0.007), 40% for the femoral block (p learning curve may be diminished.

  16. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

    Science.gov (United States)

    Cooper, H John; Urban, Robert M; Wixson, Richard L; Meneghini, R Michael; Jacobs, Joshua J

    2013-05-15

    Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. This was a multicenter retrospective case series of twelve hips (eleven patients) with adverse local tissue reactions secondary to corrosion at the modular neck-body junction. The cohort included eight women and three men who together had an average age of 60.1 years (range, forty-three to seventy-seven years); all hips were implanted with a titanium-alloy stem and cobalt-chromium-alloy neck. Patients presented with new-onset and increasing pain at a mean of 7.9 months (range, five to thirteen months) following total hip arthroplasty. After serum metal-ion studies and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) revealed abnormal results, the patients underwent hip revision at a mean of 15.2 months (range, ten to twenty-three months). Tissue specimens were examined by a single histopathologist, and the retrieved implants were studied with use of light and scanning electron microscopy. Serum metal levels demonstrated greater elevation of cobalt (mean, 6.0 ng/mL) than chromium (mean, 0.6 ng/mL) or titanium (mean, 3.4 ng/mL). MRI with use of MARS demonstrated adverse tissue reactions in eight of nine patients in which it was performed. All hips showed large soft-tissue masses and surrounding tissue damage with visible corrosion at the modular femoral neck-body junction. Available histology demonstrated large areas of tissue necrosis in seven of ten cases, while remaining viable capsular tissue showed a dense lymphocytic infiltrate. Microscopic analysis was consistent with fretting and crevice corrosion at the modular neck-body interface. Corrosion at the modular neck-body junction in dual-tapered stems with a modular

  17. Estudo do tratamento das fraturas da cabeça do fêmur Study of the treatment of femoral head fractures

    Directory of Open Access Journals (Sweden)

    Rodrigo Pereira Guimarães

    2010-01-01

    Full Text Available OBJETIVO: Estabelecer diretrizes para o tratamento das fraturas da cabeça femoral e determinar a melhor via de acesso nos casos tratados cirurgicamente. MÉTODOS: Avaliamos os resultados clínicos e radiográficos de 13 pacientes (13 fraturas tratados cirurgicamente entre maio de 1986 e julho de 1996 no Departamento de Ortopedia e Traumatologia da Santa Casa de Misericórdia de São Paulo (SCMSP, Pavilhão "Fernandinho Simonsen". RESULTADOS: Entre as seis fraturas Pipkin 1, cinco foram submetidas à ressecção do fragmento, o que nos levou a quatro resultados excelentes e um bom, sendo este com fixação do fragmento. Três pacientes apresentaram fraturas Pipkin 2 e todas foram fixadas, observados dois excelentes resultados e um regular. Dois pacientes Pipkin 3 foram submetidos à artroplastia primária. Dos dois pacientes com lesão Pipkin 4, um foi tratado com redução e osteossíntese da fratura do acetábulo, sem abordar o fragmento da cabeça que estava bem reduzido e resultou em artrose precoce, e o outro foi submetido à artroplastia total como tratamento primário. CONCLUSÃO: Concluímos após comparação da revisão da literatura com a análise dos nossos casos, que o tratamento da fratura da cabeça femoral deve ser cirúrgico e a escolha da via de acesso vai depender do tipo de fratura.OBJECTIVE: To establish guidelines for the treatment of femoral head fractures and to determine the best form of access in cases treated surgically. METHODS: We evaluated the clinical and radiological results of 13 patients (13 fractures treated surgically, between May 1986 and July 1996, at the Department of Orthopedics and Traumatology at the Santa Casa de Misericórdia de São Paulo (SCMSP, Fernandinho Simonsen Pavillion. RESULTS: Among six Pipkin 1 fractures, five had resection of the fragment, resulting in four excellent and one good result. The good result had fixation of the fragment. All three Pipkin 2 fractures had fixation of the fragment

  18. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    Science.gov (United States)

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing

  19. Subchondral insufficiency fracture of the femoral head in a patient with alkaptonuria

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Takahiro; Shida, Jun-ichi; Inokuchi, Akihiko; Arizono, Takeshi [Kyushu Central Hospital, Department of Orthopaedic Surgery, Fukuoka-city (Japan); Yamamoto, Takuaki [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Fukuoka-city (Japan)

    2014-06-15

    We report a patient with alkaptonuria accompanied by bilateral rapidly destructive arthrosis of the hip. The destruction of the left hip joint with its severe functional impairment necessitated total hip arthroplasty (THA). The outcome was satisfactory. Both magnetic resonance imaging (MRI) and pathologic findings were compatible with a subchondral insufficiency fracture. A year and half later, during a follow-up visit, the patient complained of right coxalgia. Radiography showed that the right femoral head had already disappeared, requiring THA of the right hip. Although there have been a few reports of rapid destructive hip osteoarthritis associated with ochronotic arthropathy, the pathogenesis of the destructive change is not clear. Subchondral insufficiency fracture was diagnosed on MR imaging and pathologically confirmed in our patient with alkaptonuria, suggesting that subchondral insufficiency fracture is one of the causes of ochronotic hip destruction. (orig.)

  20. Subchondral insufficiency fracture of the femoral head in a patient with alkaptonuria

    International Nuclear Information System (INIS)

    Hamada, Takahiro; Shida, Jun-ichi; Inokuchi, Akihiko; Arizono, Takeshi; Yamamoto, Takuaki

    2014-01-01

    We report a patient with alkaptonuria accompanied by bilateral rapidly destructive arthrosis of the hip. The destruction of the left hip joint with its severe functional impairment necessitated total hip arthroplasty (THA). The outcome was satisfactory. Both magnetic resonance imaging (MRI) and pathologic findings were compatible with a subchondral insufficiency fracture. A year and half later, during a follow-up visit, the patient complained of right coxalgia. Radiography showed that the right femoral head had already disappeared, requiring THA of the right hip. Although there have been a few reports of rapid destructive hip osteoarthritis associated with ochronotic arthropathy, the pathogenesis of the destructive change is not clear. Subchondral insufficiency fracture was diagnosed on MR imaging and pathologically confirmed in our patient with alkaptonuria, suggesting that subchondral insufficiency fracture is one of the causes of ochronotic hip destruction. (orig.)

  1. Subchondral insufficiency fracture of the femoral head in a patient with alkaptonuria.

    Science.gov (United States)

    Hamada, Takahiro; Yamamoto, Takuaki; Shida, Jun-ichi; Inokuchi, Akihiko; Arizono, Takeshi

    2014-06-01

    We report a patient with alkaptonuria accompanied by bilateral rapidly destructive arthrosis of the hip. The destruction of the left hip joint with its severe functional impairment necessitated total hip arthroplasty (THA). The outcome was satisfactory. Both magnetic resonance imaging (MRI) and pathologic findings were compatible with a subchondral insufficiency fracture. A year and half later, during a follow-up visit, the patient complained of right coxalgia. Radiography showed that the right femoral head had already disappeared, requiring THA of the right hip. Although there have been a few reports of rapid destructive hip osteoarthritis associated with ochronotic arthropathy, the pathogenesis of the destructive change is not clear. Subchondral insufficiency fracture was diagnosed on MR imaging and pathologically confirmed in our patient with alkaptonuria, suggesting that subchondral insufficiency fracture is one of the causes of ochronotic hip destruction.

  2. Iatrogenic popliteal artery injury in non arthroplasty knee surgery.

    Science.gov (United States)

    Bernhoff, K; Björck, M

    2015-02-01

    We have investigated iatrogenic popliteal artery injuries (PAI) during non arthroplasty knee surgery regarding mechanism of injury, treatment and outcomes, and to identify successful strategies when injury occurs. In all, 21 iatrogenic popliteal artery injuries in 21 patients during knee surgery other than knee arthroplasty were identified from the Swedish Vascular Registry (Swedvasc) between 1987 and 2011. Prospective registry data were supplemented with case-records, including long-term follow-up. In total, 13 patients suffered PAI during elective surgery and eight during urgent surgery such as fracture fixation or tumour resection. Nine injuries were detected intra-operatively, five within 12 to 48 hours and seven > 48 hours post-operatively (two days to 23 years). There were 19 open vascular and two endovascular surgical repairs. Two patients died within six months of surgery. One patient required amputation. Only six patients had a complete recovery of whom had the vascular injury detected at time of injury and repaired by a vascular surgeon. Patients sustaining vascular injury during elective procedures are more likely to litigate (p = 0.029). We conclude that outcomes are poorer when there is a delay of diagnosis and treatment, and that orthopaedic surgeons should develop strategies to detect PAI early and ensure rapid access to vascular surgical support. ©2015 The British Editorial Society of Bone & Joint Surgery.

  3. BONE GRAFTING ENHANCED BY PLATELET-RICH PLASMA IN TREATMENT OF AVASCULAR NECROSIS OF FEMORAL HEAD

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2018-01-01

    Full Text Available Treatment of avascular necrosis of the femoral head is an issue of current interest while it affects young and employable people. So far there is no well-defined strategy of management which would help to postpone hip arthroplasty and further revision procedure. Hip sparing surgical treatment of avascular necrosis of the femoral head by bone grafting prior to head collapse proved to be a viable option not only during early stages of disease but also at advanced stages. Platelet-rich plasma (PRP addition to treatment plan potentially helps improving bone regeneration in situ.In this article the authors present a case of a 37 years old patient with avascular necrosis of the femoral head at a fragmentation stage (type 4B by ARCO. The authors centrifuged 15 ml of autologous whole blood (1500 RPM obtained by a special double-contoured syringe. During the surgical stage of treatment PRP and morselized bone graft were mixed to introduce and impact into the debrided zone of avascular necrosis. The authors also introduced 0.3–0.4 ml of PRP into the debrided zone of avascular necrosis after bone grafting. At 6 months follow-up CT images of the studied patient demonstrated signs of bone reorganization and no loss of femoral head sphericity. Preoperative Visual Analogue Scale (VAS, Harris Hip Score (HHS and Hip disability and Osteoarthritis Outcome Score (HOOS prior to treatment were 60, 45 and 33 points respectively. Postoperative VAS, HHS and HOOS scores were 10, 78 and 78 respectively. In the authors’ opinion, impaction bone grafting enhanced by PRP helps obtaining good and excellent outcomes not only at early but also at advanced stages of avascular necrosis.

  4. Study of healing process and prognosis of medial femoral neck fracture evaluated by bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K [Yokohama City Univ. (Japan). Faculty of Medicine

    1981-02-01

    As to healing process and prognosis of femoral neck fracture, radionuclide bone scintigraphy using sup(99m)Tc phosphorus compound was performed and the following results were obtained. 1. In cases of osteosynthesis, scintigraphical study showed a certain serial pattern until fracture was uneventfully healed. 2. On the other hand, in cases with non-union or late segmental collapse of the head, scintigraphy revealed defect at superolateral or central area in the head. This finding could be already noted prior to roentgenographical evaluation. 3. In the study of radionuclide uptake count on the femoral head of resected specimen, the higher value was observed in the area along medial fracture edge to medial margin of the head. Histological study showed feature of increased new bone formation at the area of higher radionuclide uptake. Vascular supply through the bone marrow of the neck and superior retinacular artery was thought to play an important role for the new bone formation. 4. From the aforementioned results, sup(99m)Tc phosphorus compound scintigraphy was considered as one of the quite useful methods for early diagnosis of complications after femoral neck fracture.

  5. Combined osteoplasty of metaepiphysial defects in total knee arthroplasty with osteoplastic biomaterial

    Directory of Open Access Journals (Sweden)

    Gavrilov М.А.

    2012-12-01

    Full Text Available The research goal is to study the results of osteoplastic biomaterials application to reach the improvement of primary and long-term secondary stability of fixation. Materials and methods: 62 patients with bone defect of metaepiphy-sis of type 2 according to AORI have been included into the research. Total knee arthroplasty with osteoplasty of the defect has been carried out in all the patients. In the basic group (n=32 combined osteoplasty has been used, and in comparison group (n=30 cement osteoplasty has been applied. In cases with total arthroplasty in the basic group modifying standard resections, structural autograft of laminar form has been received simultaneously. After preparing the floor of the defect its plasty has been carried out: in the basic group the defect has been filled with osteoconductive biomaterial, and in the comparison group — with polymethylmethacrylate to restore the anatomical configuration of condyles. Besides, before cement fixation of the prosthesis in the basic group the received autograft has been put on the restored implant plateau. Results: Assessing the results during the period from 2 to 4 years objective criteria have included the data of X-ray imaging, biomechanical research and WOMAC test. In the postoperative period significant differences have not been revealed. In the follow-up period in the group with application of the combined osteoplasty joint remodulation of autograft and osteoplastic biomaterial with regenerative restoration of bone tissue of the implant plateau has been observed. Conclusion: The described technique may reduce the relative risk of revision arthroplasty.

  6. Instability following total knee arthroplasty.

    Science.gov (United States)

    Rodriguez-Merchan, E Carlos

    2011-10-01

    Background Knee prosthesis instability (KPI) is a frequent cause of failure of total knee arthroplasty. Moreover, the degree of constraint required to achieve immediate and long-term stability in total knee arthroplasty (TKA) is frequently debated. Questions This review aims to define the problem, analyze risk factors, and review strategies for prevention and treatment of KPI. Methods A PubMed (MEDLINE) search of the years 2000 to 2010 was performed using two key words: TKA and instability. One hundred and sixty-five initial articles were identified. The most important (17) articles as judged by the author were selected for this review. The main criteria for selection were that the articles addressed and provided solutions to the diagnosis and treatment of KPI. Results Patient-related risk factors predisposing to post-operative instability include deformity requiring a large surgical correction and aggressive ligament release, general or regional neuromuscular pathology, and hip or foot deformities. KPI can be prevented in most cases with appropriate selection of implants and good surgical technique. When ligament instability is anticipated post-operatively, the need for implants with a greater degree of constraint should be anticipated. In patients without significant varus or valgus malalignment and without significant flexion contracture, the posterior cruciate ligament (PCL) can be retained. However, the PCL should be sacrificed when deformity exists particularly in patients with rheumatoid arthritis, previous patellectomy, previous high tibial osteotomy or distal femoral osteotomy, and posttraumatic osteoarthritis with disruption of the PCL. In most cases, KPI requires revision surgery. Successful outcomes can only be obtained if the cause of KPI is identified and addressed. Conclusions Instability following TKA is a common cause of the need for revision. Typically, knees with deformity, rheumatoid arthritis, previous patellectomy or high tibial osteotomy, and

  7. Femoral nerve damage (image)

    Science.gov (United States)

    The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...

  8. The threshold force required for femoral impaction grafting in revision hip surgery.

    LENUS (Irish Health Repository)

    Flannery, Olivia M

    2010-06-01

    BACKGROUND AND PURPOSE: Femoral impaction grafting requires vigorous impaction to obtain adequate stability without risk of fracture, but the force of impaction has not been determined. We determined this threshold force in a preliminary study using animal femurs. METHODS: Adult sow femurs were used because of their morphological similarity to human femurs in revision hip arthroplasty. 35 sow femurs were impacted with morselized bone chips and an increasing force was applied until the femur fractured. This allowed a threshold force to be established. 5 other femurs were impacted to this force and an Exeter stem was cemented into the neomedullary canal. A 28-mm Exeter head was attached and loaded by direct contact with a hydraulic testing machine. Axial cyclic loading was performed and the position sensor of the hydraulic testing machine measured the prosthetic head subsidence. RESULTS: 29 tests were completed successfully. The threshold force was found to be 4 kN. There was no statistically significant correlation between the load at fracture and the cortex-to-canal ratio or the bone mineral density. Following impaction with a maximum force of 4 kN, the average axial subsidence was 0.28 mm. INTERPRETATION: We achieved a stable construct without fracture. Further studies using human cadaveric femurs should be done to determine the threshold force required for femoral impaction grafting in revision hip surgery.

  9. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements

    DEFF Research Database (Denmark)

    Miles, James Edward

    2016-01-01

    Objective: To describe the effects of internal and external femoral rotation on radiographic measurements of the anatomical lateral distal femoral angle (a-LDFA) using two methods for defining the anatomical proximal femoral axis (a-PFA). Methods: Digital radiographs were obtained of 14 right...... femora at five degree intervals from 10° external rotation to 10° internal rotation. Using freely available software, a-LDFA measurements were made using two different a-PFA by a single observer on one occasion. Results: Mean a-LDFA was significantly greater at 10° external rotation than at any other...... rotation. The response of individual femora to rotation was unpredictable, although fairly stable within ±5° of zero rotation. Mean a-LDFA for the two a-PFA methods differed by 1.5°, but were otherwise similarly affected by femoral rotation. Clinical significance: If zero femoral elevation can be achieved...

  10. Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Greene, M. E.; Laursen, M B

    2017-01-01

    Aims: The objective of this five-year prospective, blinded, randomised controlled trial (RCT) was to compare femoral head penetration into a Vitamin E diffused highly cross-linked polyethylene (HXLPE) liner with penetration into a medium cross-linked polyethylene control liner using......, ArComXL. This is the longest-term RCT comparing the wear performance and clinical outcome of Vitamin E diffused HXLPE with a previous generation of medium cross-linked polyethylene....... radiostereometric analysis. Patients and Methods: Patients scheduled for total hip arthroplasty (THA) were randomised to receive either the study E1 (32 patients) or the control ArComXL polyethylene (35 patients). The median age (range) of the overall cohort was 66 years (40 to 76). Results: The five-year median...

  11. Relevance of infiltration analgesia in pain relief after total knee arthroplasty

    Science.gov (United States)

    Znojek-Tymborowska, Justyna; Kęska, Rafał; Paradowski, Przemysław T.; Witoński, Dariusz

    2013-01-01

    OBJECTIVE: The aim of the study was to assess the effect of different types of anesthesia on pain intensity in early postoperative period. PATIENTS AND METHODS: A total of 87 patients (77 women, 10 men) scheduled for total knee arthroplasty (TKA) were assigned to receive either subarachnoid anesthesia alone or in combination with local soft tissue anesthesia, local soft tissue anesthesia and femoral nerve block and pre-emptive infiltration together with local soft tissue anesthesia. We assessed the pain intensity, opioid consumption, knee joint mobility, and complications of surgery. RESULTS: Subjects with pre-emptive infiltration and local soft tissue anesthesia had lower pain intensity on the first postoperative day compared to those with soft tissue anesthesia and femoral nerve block (P=0.012, effect size 0.68). Subjects who received pre-emptive infiltration and local soft-tissue anesthesia had the greatest range of motion in the operated knee at discharge (mean 90 grades [SD 7], P=0.01 compared to those who received subarachnoid anesthesia alone, and P=0.001 compared to those with subarachnoid together with soft tissue anesthesia). CONCLUSION: Despite the differences in postoperative pain and knee mobility, the results obtained throughout the postoperative period do not enable us to favour neither local nor regional infiltration anesthesia in TKA. Level of Evidence II, Prospective Comparative Study. PMID:24453679

  12. Influence of bone density on the cement fixation of femoral hip resurfacing components.

    Science.gov (United States)

    Bitsch, Rudi G; Jäger, Sebastian; Lürssen, Marcus; Loidolt, Travis; Schmalzried, Thomas P; Clarius, Michael

    2010-08-01

    In clinical outcome studies, small component sizes, female gender, femoral shape, focal bone defects, bad bone quality, and biomechanics have been associated with failures of resurfacing arthroplasties. We used a well-established experimental setup and human bone specimens to analyze the effects of bone density on cement fixation of femoral hip resurfacing components. Thirty-one fresh frozen femora were prepared for resurfacing using the original instruments. ASR resurfacing prostheses were implanted after dual-energy X-ray densitometer scans. Real-time measurements of pressure and temperature during implantation, analyses of cement penetration, and measurements of micro motions under torque application were performed. The associations of bone density and measurement data were examined calculating regression lines and multiple correlation coefficients; acceptability was tested with ANOVA. We found significant relations between bone density and micro motion, cement penetration, cement mantle thickness, cement pressure, and interface temperature. Mean bone density of the femora was 0.82 +/- 0.13 g/cm(2), t-score was -0.7 +/- 1.0, and mean micro motion between bone and femoral resurfacing component was 17.5 +/- 9.1 microm/Nm. The regression line between bone density and micro motion was equal to -56.7 x bone density + 63.8, R = 0.815 (p density scans are most helpful for patient selection in hip resurfacing, and a better bone quality leads to higher initial component stability. A sophisticated cementing technique is recommended to avoid vigorous impaction and incomplete seating, since increasing bone density also results in higher cement pressures, lower cement penetration, lower interface temperatures, and thicker cement mantles. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Low bone mineral density is not related to failure in femoral neck fracture patients treated with internal fixation

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Overgaard, Søren

    2014-01-01

    the importance of low bone mineral density (BMD). Patients and methods - 140 consecutive patients (105 females, median age 80) treated with IF had a dual-energy X-ray absorptiometry (DXA) scan of the hip performed median 80 days after treatment. The patients' radiographs were evaluated for fracture displacement......, implant positioning, and quality of reduction. From a questionnaire completed during admission, 2 variables for comorbidity and walking disability were chosen. Primary outcome was low hip BMD (amount of mineral matter per square centimeter of hip bone) compared to hip failure (resection, arthroplasty...

  14. Stemless shoulder arthroplasty: current status.

    Science.gov (United States)

    Churchill, R Sean

    2014-09-01

    Since the original Neer humeral replacement in the 1950s, the standard primary anatomic total shoulder arthroplasty design has slowly evolved. Most recently, the humeral stem has become progressively shorter to help combat stem-related complications. Currently, there are several companies who have developed and marketed a stemless humeral arthroplasty component. Manufacturers' data for 5 stemless shoulder arthroplasty components currently on the market were analyzed and reviewed. A literature review of short-term results for stemless shoulder arthroplasty was completed. Of the stemless shoulder arthroplasty systems available on the market, 3 are currently undergoing clinical trials in the United States. The Tornier Simpliciti (Tornier, Edina, MN, USA) clinical trial began in 2011. The study with 2-year minimum follow-up results is scheduled for completion in November 2014. The Arthrex Eclipse (Arthrex, Naples, FL, USA) clinical trial was started in January 2013. The tentative study completion date is 2017. The Biomet Nano (Biomet, Warsaw, IN, USA) clinical trial began in October 2013 and also has a tentative completion date of 2017. No other clinical trial is currently under way in the United States. Early results for stemless shoulder arthroplasty indicate clinical results similar to standard stemmed shoulder arthroplasty. Radiographic analysis indicates implant stability without migration or subsidence at 2- to 3-year minimum follow-up.. Several stemless shoulder arthroplasty implants are available outside the United States. Early clinical and radiographic results are promising, but well-designed clinical studies and midterm results are lacking. Three clinical trials are currently under way in the United States with initial availability for use anticipated in 2015. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  15. Pedicle Anterolateral Thigh Flap Reconstruction after Pelvic Tumor Resection: A Case Report

    Directory of Open Access Journals (Sweden)

    Robert M. Whitfield

    2010-01-01

    Full Text Available A 47-year-old female with a locally advanced urologic malignancy previously managed with resection, diversion, and postoperative radiation therapy presented for management of her recurrent cancer that had eroded through the soft tissues of the left inner thigh and vulva. On all staging studies the tumor involved the left common femoral artery, and vein, both above and below the inguinal ligament. The difficulty with such tumors is the availability of tissue to reconstruct the defect. The patient had a history of deep venous thrombosis in the femoral venous system. A local flap was the most logical type of reconstruction. The patient had a right lower quadrant ureterostomy with a large parastomal hernia which further limited the local flap options. An anterolateral thigh flap from the opposite thigh was used to reconstruct the soft tissue deficit in this patient. This resurfaced the defect and provided coverage for the vascular reconstruction.

  16. Arthroplasty register for Germany

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2009-10-01

    Full Text Available Scientific background: The annual number of joint replacement operations in Germany is high. The introduction of an arthroplasty register promises an important contribution to the improvement of the quality of patient’s care. Research questions: The presented report addresses the questions on organization and functioning, benefits and cost-benefits as well as on legal, ethical and social aspects of the arthroplasty registers. Methods: A systematic literature search was conducted in September 2008 in the medical databases MEDLINE, EMBASE etc. and was complemented with a hand search. Documents describing arthroplasty registers and/or their relevance as well as papers on legal, ethical and social aspects of such registers were included in the evaluation. The most important information was extracted and analysed. Results: Data concerning 30 arthroplasty registers in 19 countries as well as one international arthroplasty register were identified. Most of the arthroplasty registers are maintained by national orthopedic societies, others by health authorities or by their cooperation. Mostly, registries are financially supported by governments and rarely by other sources.The participation of the orthopedists in the data collection process of the arthroplasty registry is voluntary in most countries. The consent of the patients is usually required. The unique patient identification is ensured in nearly all registers.Each data set consists of patient and clinic identification numbers, data on diagnosis, the performed intervention, the operation date and implanted prostheses. The use of clinical scores, patient-reported questionnaires and radiological documentation is rare. Methods for data documentation and transfer are paper form, electronic entry as well as scanning of the data using bar codes. The data are mostly being checked for their completeness and validity. Most registers offer results of the data evaluation to the treating orthopedists and

  17. 99mTc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    International Nuclear Information System (INIS)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong

    1985-01-01

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head

  18. Primary total knee arthroplasty assisted by computer (orthopilot)

    International Nuclear Information System (INIS)

    Naquira, Luis Felipe; Restrepo Tello, Fabio; Pineda Acero, Gustavo; Clavijo, Edgar; Buitrago, Mario

    2004-01-01

    Between December 2001 and December 2003, 21 patients suffering from osteoarthrosis of the knee were treated using computer assisted complete primary arthroplasty of the knee (Orthopilot) at the Department of Orthopedics and Traumatology in the Hospital Militar Central. Results were followed up for an average of 18 months. The criteria evaluated were function and mechanical axis, using ortho-radiography, and length of surgery. The average value obtained was 4.3 degrades with a mechanical axis passing through the centre of the knee joint in 95% of cases, confirmed by a mechanical femoral-tibial angle of -2.5 degrades. Length of surgery was increased by an average of 1 hour compared to the conventional technique. Complications were as follows: One patient experienced an infection which required the withdrawal of the prosthesis and in four of the operations technical problems with the navigator made it necessary to proceed using conventional techniques and these patients were excluded from the study. Radiological results ranged from Excellent to Good in 100% of cases

  19. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads.

    Science.gov (United States)

    Yamane, Shihori; Kyomoto, Masayuki; Moro, Toru; Hashimoto, Masami; Takatori, Yoshio; Tanaka, Sakae; Ishihara, Kazuhiko

    2018-04-01

    Younger, active patients who undergo total hip arthroplasty (THA) have increasing needs for wider range of motion and improved stability of the joint. Therefore, bearing materials having not only higher wear resistance but also mechanical strength are required. Carbon fiber-reinforced poly(ether ether ketone) (CFR-PEEK) is known as a super engineering plastic that has great mechanical strength. In this study, we focused on poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted CFR-PEEK and investigated the effects of PMPC grafting and the femoral heads materials on the wear properties of CFR-PEEK liners. Compared with untreated CFR-PEEK, the PMPC-grafted CFR-PEEK surface revealed higher wettability and lower friction properties under aqueous circumstances. In the hip simulator wear test, wear particles generated from the PMPC-grafted CFR-PEEK liners were fewer than those of the untreated CFR-PEEK liners. There were no significant differences in the size and the morphology of the wear particles between the differences of PMPC-grafting and the counter femoral heads. Zirconia-toughened alumina (ZTA) femoral heads had significantly smoother surfaces compared to cobalt-chromium-molybdenum alloy femoral heads after the hip simulator test. Thus, we conclude that the bearing combination of the PMPC-grafted CFR-PEEK liner and ZTA head is expected to be a lifelong bearing interface in THA. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1028-1037, 2018. © 2017 Wiley Periodicals, Inc.

  20. Comparison of peri- and intraarticular analgesia with femoral nerve block after total knee arthroplasty: a randomized clinical trial

    DEFF Research Database (Denmark)

    Toftdahl, Karen; Nikolajsen, Lone; Haraldsted, Viggo

    2007-01-01

    to receive continuous femoral nerve block (group F) or peri- and intraarticular infiltration and injection (group I). Group I received a solution of 300 mg ropivacaine, 30 mg ketorolac, and 0.5 mg epinephrine by infiltration of the knee at the end of surgery, and 2 postoperative injections...

  1. Fate of bulk auto grafts in uncemented total hip arthroplasty: Evaluation by bone scintigraphy

    International Nuclear Information System (INIS)

    Simsek, A.; Cila, E.; Sener, E.; Senkoylu, A.; Sipahioglu, S.; Atasever, T.; Akdemir, Ozgur

    2006-01-01

    Objective was to review short term results of uncemented cup implantation and the fate of bulk femoral head autografts in patients with acetabular bone deficiency due to dysplasia of the hip. We used bone scintigraphy to assess the viability of the grafts. We treated 19 hip joints of 17 patients with osteoarthritis due to developmental dysplasia of the hip with uncemented total hip arthroplasty between 1997-2003 in the Department of Orthopedics and Traumatology, Gazi University, Ankara, Turkey. The average age was 49.1 (31-72 years), and the average follow up period was 36 months. We used femoral head autografts to reconstruct superolateral segmental deficiencies of the acetabuli. We evaluated the patients clinically and radiologically to assess acetabular loosening, and we used three-phase bone scintigraphy to evaluate the viability of the autograft.There was no acetabular component revision throughout the follow up period. There was no radiological evidence of graft resorption or graft displacement in any of the patients. In bone scintigraphy, we observed hyperemia in the blood pool phase, and the osteoblastic activity of the bone graft was at the level of the neighboring iliac bone. The application of a non-cemented acetabular component with femoral autograft in superolateral acetabulum deficiency increases the stability of the implant and increases the bone stock. It is not easy to evaluate the viability of the graft by the use of radiological methods. Bone scintigraphy gives sufficient information about the viability of the graft as a non-invasive method. (author)

  2. Management of osteonecrosis of the femoral head: A novel technique

    Directory of Open Access Journals (Sweden)

    Ahmed M Samy

    2016-01-01

    Full Text Available Background: Osteonecrosis of the femoral head (ONFH is a debilitating disease in orthopedics, frequently progressing to femoral head collapse and osteoarthritis. It is thought to be a multifactorial disease. ONFH ultimately results in femoral head collapse in 75-85% of untreated patients. Total hip arthroplasty (THA yields satisfactory results in the treatment of the end stage of the disease. However, disease typically affects males between the ages of 20 and 40 years and joint replacement is not the ideal option for younger patients. Recently, mesenchymal stem cells and platelet rich plasma (PRP have been used as an adjunct to core decompression to improve clinical success in the treatment of precollapse hips. Materials and Methods: A prospective study of 40 hips in 30 patients was done. There were 19 males and 11 females with a mean age 36.7 ± 6.93 years. The indication for the operation was restricted primarily to modified Ficat stages IIb and III. 16 hips (40% had stage IIb and 24 hips (60% had stage III ONFH. The period of follow up ranged between 36-50 months with a mean 41.4 ± 3.53 months. All patients were assessed clinically during pre- and post-operative period according to the Harris Hip Score (HHS, Visual Analog Score (VAS and radiologically by X-rays. Magnetic resonance imaging (MRI was done preoperatively to confirm the diagnosis and every 6 months postoperatively for assessment of healing. The operative procedure include removal of necrotic area with drilling then the cavity was filled with a composite of bone graft mixed with PRP. Results: The mean HHS improved from 46.0 ± 7.8 preoperatively to 90.28 ± 19 at the end of followup ( P < 0.0001. The mean values of VAS were 78 ± 21 and 35 ± 19 at preoperatively period and final followup, respectively, with an average reduction of 43 points. Conclusion: We found that the use of PRP with collagen sheet can increase the reparable capacity after drilling of necrotic segment in stage

  3. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur

    Directory of Open Access Journals (Sweden)

    Sung-Yen Lin

    2014-08-01

    Full Text Available Total knee arthroplasty (TKA in patients with knee arthritis and retained implants in the ipsilateral femur is a challenge for knee surgeons. Use of a conventional intramedullary femoral cutting guide is not practical because of the obstruction of the medullary canal by implants. Previous studies have shown that computer-assisted surgery (CAS can help restore alignment in conventional TKA for patients with knee arthritis with retained femoral implants or extra-articular deformity, without the need for implant removal or osteotomy. However, little has been published regarding outcomes with the use of navigation in minimally invasive surgery (MIS-TKA for patients with this complex knee arthritis. MIS has been proven to provide less postoperative pain and faster recovery than conventional TKA, but MIS-TKA in patients with retained femoral implants poses a greater risk in limb malalignment. The purpose of this study is to report the outcome of CAS-MIS-TKA in patients with knee arthritis and retained femoral implants. Between April 2006 and March 2008, eight patients with knee arthritis and retained femoral implants who underwent the CAS-MIS-TKA were retrospectively reviewed. Three of the eight patients had extra-articular deformity, including two femur bones and one tibia bone, in the preoperative examination. The anteroposterior, lateral, and long-leg weight-bearing radiographs carried out at 3-month follow-up was used to determine the mechanical axis of lower limb and the position of components. The mean preoperative femorotibial angle in patients without extra-articular deformity was 3.8° of varus and was corrected to 4.6° of valgus. With the use of navigation in MIS-TKA, the two patients in this study with extra-articular femoral deformity also obtained an ideal postoperative mechanical axis within 2° of normal alignment. Overall, there was a good restoration of postoperative mechanical alignment in all cases, with a mean angle of 0.4° of

  4. Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration

    Directory of Open Access Journals (Sweden)

    Pei-Hui Wu

    2016-01-01

    Conclusions: Using conventional surgical instruments, preoperative measurement of resection thickness of the tibial plateau on radiographs could improve the accuracy of conventional surgical techniques.

  5. Imaging and histopathological evaluation of a cystlike formation in subchondral insufficiency fracture of the femoral head: A case report and literature review.

    Science.gov (United States)

    Fukui, Kiyokazu; Kaneuji, Ayumi; Fukushima, Mana; Matsumoto, Tadami

    2014-01-01

    In the majority of subchondral insufficiency fractures (SIFs) of the femoral head, T1-weighted magnetic resonance imaging shows an irregular, serpiginous, low-intensity band that is convex to the articular surface. We report a case of a cystlike formation in SIF of the femoral head in an elderly woman. A 71-year-old woman reported right hip pain without any history of antecedent trauma. The initial radiograph showed a slight narrowing of the joint space in the right hip. The patient was treated with conservative therapy for 2 months. Radiographs obtained 3 months after the onset of pain showed non-progressive joint-space narrowing. T1-weighted magnetic resonance images obtained 2 months after pain onset revealed a round, cystlike, low-intensity area just beneath the articular cartilage. The patient underwent total hip arthroplasty. Histopathological examination showed fracture callus and granulation tissue in the subchondral area, surrounded by vascular-rich granulation tissue and fibrous tissue, which corresponded to the round, low-intensity band observed on the T1-weighted image. This case was a rare SIF of the femoral head which had a cystlike formation with a low signal intensity on T1-weighted images and a very high signal intensity on STIR sequences in the superolateral portion of the femoral head, surrounded by a pattern of edema in the bone marrow. To our knowledge, no similar cases were cited in the literature. It is important for surgeons to keep in mind that sometimes SIFs of the femoral head can appear as a round cystlike formation. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty.

    Science.gov (United States)

    Sato, Taishi; Nakashima, Yasuharu; Akiyama, Mio; Yamamoto, Takuaki; Mawatari, Taro; Itokawa, Takashi; Ohishi, Masanobu; Motomura, Goro; Hirata, Masanobu; Iwamoto, Yukihide

    2012-12-01

    The purpose of this study was to examine the effects of ceramic femoral head material, size, and implantation periods on the wear of annealed, cross-linked ultra-high molecular weight polyethylene (UHMWPE) (XLPE) in total hip arthroplasty compared to non-cross-linked conventional UHMWPE (CPE). XLPE was fabricated by cross-linking with 60 kGy irradiation and annealing. Femoral heads made from zirconia and alumina ceramics and cobalt-chrome (CoCr) of 22 or 26 mm diameter were used. In this retrospective cohort study, the femoral head penetration into the cup was measured digitally on radiographs of 367 hips with XLPE and 64 hips with CPE. The average follow-up periods were 6.3 and 11.9 years, respectively. Both XLPE creep and wear rates were significantly lower than those of CPE (0.19 mm vs. 0.44 mm, 0.0001 mm/year vs. 0.09 mm/year, respectively). Zirconia displayed increased wear rates compared to alumina in CPE; however, there was no difference among head materials in XLPE (0.0008, 0.00007, and -0.009 mm/year for zirconia, alumina, and CoCr, respectively). Neither head size or implantation period impacted XLPE wear. In contrast to CPE, XLPE displayed low wear rates surpassing the effects of varying femoral head material, size, implantation period, and patient demographics. Further follow-up is required to determine the long-term clinical performance of the annealed XLPE. Copyright © 2012 Orthopaedic Research Society.

  7. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

    Science.gov (United States)

    Howell, Stephen M; Hodapp, Esther E; Vernace, Joseph V; Hull, Maury L; Meade, Thomas D

    2013-10-01

    Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.

  8. The efficiency of risedronate in reducing bone resorption after total hip arthroplasty: a meta-analysis of randomized control trials at a minimum of 6 months' follow-up.

    Science.gov (United States)

    Yang, Liqing

    2018-04-17

    Recently risedronate is suggested to be effective for the prevention and treatment of for osteoporosis in total hip arthroplasty. This meta-analysis aimes to evaluate the efficacy of risedronate in reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty. A systematic search was performed in Medline (1966-31 October 2017), PubMed (1966-31 October 2017), Embase (1980-31 October 2017), ScienceDirect (1985-31 October 2017) and the Cochrane Library. Only randomized controlled trial (RCT) were included. Fixed/random effect model was used according to the heterogeneity tested by I2 statistic. Meta-analysis was performed using Stata 11.0 software. The outcome measures included periprosthetic bone mineral density, length of stay and adverse effects. Four RCTs including 198 patients met the inclusion criteria. The present meta-analysis showed that there were significant differences between treatment groups in terms of periprosthetic bone mineral density in Gruen zones 1 (standard mean difference (SMD) = 0.758, 95% CI 0.469 to 1.047, P = 0.000), 2 (SMD = 0.814, 95% CI 0.523 to 1.106, P = 0.000), 3 (SMD = 0.340, 95% CI 0.059 to 0.622, P = 0.018), 6 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000), and 7 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000). Oral risedronate could significantly reduce periprosthetic bone resorption around an uncemented femoral stem (Gruen zones 1, 2, 3, 6, and 7) up to 6 months after THA. In addition, no severe adverse events were identified. Future trials of risedronate treatment after THA should focus on clinically relevant end points such as the risks of fracture and revision arthroplasty.

  9. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

    Science.gov (United States)

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. Concerning the use of porous

  10. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  11. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  12. Bone mineral density after implantation of a femoral neck hip prosthesis--a prospective 5 year follow-up.

    Science.gov (United States)

    Steens, Wolfram; Boettner, Friedrich; Bader, Rainer; Skripitz, Ralf; Schneeberger, Alberto

    2015-08-12

    Bone resorption in the proximal femur due to stress shielding has been observed in a number of conventional cementless implants used in total hip arthroplasty. Short femoral-neck implants are claiming less interference with the biomechanics of the proximal femur. The goal of this study was to prospectively investigate the in vivo changes of bone-mineral density as a parameter of bone remodeling around a short, femoral neck prosthesis over the first 5 years following implantation. The secondary goal was to report on its clinical outcome. We are reporting on the changes of bone mineral density of the proximal femur and the clinical outcome up to five years after implantation of a short femoral neck prosthesis. Bone mineral density was determined using dual energy x-ray absorptiometry, performed 10 days, three, 12 and 60 months after surgery. 20 patients with a mean age of 47 years (range 17 to 65) were clinically assessed using the Harris Hip Score. The WOMAC was used as a patient-relevant outcome-measure. In contrast to conventional implants DEXA-scans overall revealed a slight increase of bone mineral density in the proximal femur in the 12 months following the implantation. The Harris Hip Score improved from an average preoperative score of 46 to a postoperative score at 12 months of 91 points and 95 points at 60 months, the global WOMAC index from 5.3 preoperatively to 0.8 at 12 months and 0.6 at 60 months postoperatively. At 60 months after implantation of a short femoral neck prosthesis, all regions except one (region of interest #5) showed no significant changes in BMD compared to baseline measurements at 10 days which is less to the changes in bone mineral density seen in conventional implants.

  13. Partial-limb salvage after persistent infection in the distal femoral prosthesis: straight-plasty - a novel technique

    International Nuclear Information System (INIS)

    Kundu, Z. S.; Gupta, V.; Gogna, P.

    2014-01-01

    A 35 years old female had giant cell tumour (GCT) of the distal femur for which wide resection and distal femoral endoprosthetic replacement was performed. Massive infection of prosthesis required removal and replacement of the prosthesis with nail antibiotic cement spacer, which also proved to be futile. Ultimately the whole of the infected thigh had to be excised. The limb could be preserved partially using straight-plasty instead of amputation. Patient is well rehabilitated and doing well at a follow-up of 3 years. (author)

  14. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Satoshi; Ishido, Yasuhiro [Saiseikai Sendai Hospital, Kagoshima (Japan); Okano, Toshihiro [Ibusuki National Hospital, Kagoshima (Japan); Komiya, Setsuro [Kagoshima Univ. (Japan). Faculty of Medicine

    2002-09-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  15. Evaluation of perfusion of the femoral head after femoral neck fracture using bone scintigraphy

    International Nuclear Information System (INIS)

    Yamaguchi, Satoshi; Ishido, Yasuhiro; Okano, Toshihiro; Komiya, Setsuro

    2002-01-01

    We treated 13 patients for femoral neck fracture. They consisted of 2 males and 11 females, and were classified according to Garden stage classification; Stage I, 3 cases; Stage II, 2 cases; Stage III, 2 cases; Stage IV, 4 cases. Two trochanteric fracture cases were used by control. We evaluated perfusion of the femoral head after femoral neck fracture using bone scintigraphy, which is considered useful for evaluation of perfusion of the femoral neck before operation. (author)

  16. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Virulsri, Chanyaphan; Tangpornprasert, Pairat; Romtrairat, Parineak

    2015-01-01

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  17. Low-Energy Traumatic Obturator Hip Dislocation with Ipsilateral Femoral Shaft Fracture in a Patient with Omolateral Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    G. Gazzotti

    2016-01-01

    Full Text Available Ipsilateral obturator hip dislocation and femoral shaft fracture are rare. We report such a case in an older woman after a low-energy injury. She had a knee prostheses in the same limb. The patient was treated by open manipulative reduction of the luxation without opening joint and open reduction and internal fixation of the femur with angular stability plate and screws. We could not find a similar case in the literature. An early diagnosis of the dislocation is crucial in order to obtain good results. Great awareness and radiologic examination are fundamental to achieve precocious diagnosis of both these rare combined injuries, as treatment in these cases is considered an emergency. The first step was an attempt to reduce the dislocation by closed means but it failed. Then we performed a short approach at the trochanteric region and used Lambotte forceps to manoeuvre the proximal femur without opening the joint achieving reduction. Thereafter the femoral shaft fracture underwent open reduction and internal fixation with an angular stable plate. After a 2-year follow-up the outcome was very good.

  18. Comparison of femoral morphology and bone mineral density between femoral neck fractures and trochanteric fractures.

    Science.gov (United States)

    Maeda, Yuki; Sugano, Nobuhiko; Saito, Masanobu; Yonenobu, Kazuo

    2011-03-01

    Many studies that analyzed bone mineral density (BMD) and skeletal factors of hip fractures were based on uncalibrated radiographs or dual-energy xray absorptiometry (DXA). Spatial accuracy in measuring BMD and morphologic features of the femur with DXA is limited. This study investigated differences in BMD and morphologic features of the femur between two types of hip fractures using quantitative computed tomography (QCT). Forty patients with hip fractures with normal contralateral hips were selected for this study between 2003 and 2007 (trochanteric fracture, n=18; femoral neck fracture, n=22). Each patient underwent QCT of the bilateral femora using a calibration phantom. Using images of the intact contralateral femur, BMD measurements were made at the point of minimum femoral-neck cross-sectional area, middle of the intertrochanteric region, and center of the femoral head. QCT images also were used to measure morphologic features of the hip, including hip axis length, femoral neck axis length, neck-shaft angle, neck width, head offset, anteversion of the femoral neck, and cortical index at the femoral isthmus. No significant differences were found in trabecular BMD between groups in those three regions. Patients with trochanteric fractures showed a smaller neck shaft angle and smaller cortical index at the femoral canal isthmus compared with patients with femoral neck fractures. We conclude that severe osteoporosis with thinner cortical bone of the femoral diaphysis is seen more often in patients with trochanteric fracture than in patients with femoral neck fracture. Level IV, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

  19. {sup 99m}Tc-MDP scintigraphy of femoral head necrosis following femoral neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soon Jin; Lee, Jun Hyung; Kim, Eun Kyung; Lee, Sun Wha; Kim, Soon Yong [Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in 9 cases (75%) and radiography showed decreased density in 9 cases (75%). 3. 99mTc-MDP scintigraphy was an excellent and useful method for assessing bone vitality of femoral head.

  20. Advances in Patellofemoral Arthroplasty.

    Science.gov (United States)

    Strickland, Sabrina M; Bird, Mackenzie L; Christ, Alexander B

    2018-06-01

    To describe current indications, implants, economic benefits, comparison to TKA, and functional and patient-reported outcomes of patellofemoral arthroplasty. Modern onlay implants and improved patient selection have allowed for recent improvements in short- and long-term outcomes after patellofemoral joint replacement surgery. Patellofemoral arthroplasty has become an increasingly utilized technique for the successful treatment of isolated patellofemoral arthritis. Advances in patient selection, implant design, and surgical technique have resulted in improved performance and longevity of these implants. Although short- and mid-term data for modern patellofemoral arthroplasties appear promising, further long-term clinical studies are needed to evaluate how new designs and technologies will affect patient outcomes and long-term implant performance.

  1. Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy.

    Science.gov (United States)

    Zeller, Ian M; Sharma, Adrija; Kurtz, William B; Anderle, Mathew R; Komistek, Richard D

    2017-04-01

    Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function. Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence. Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIM TKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects. The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years.

    Science.gov (United States)

    Kadar, Thomas; Hallan, Geir; Aamodt, Arild; Indrekvam, Kari; Badawy, Mona; Havelin, Leif Ivar; Stokke, Terje; Haugan, Kristin; Espehaug, Birgitte; Furnes, Ove

    2011-10-01

    We performed a randomized study to determine the migration patterns of the Spectron EF femoral stem and to compare them with those of the Charnley stem, which is regarded by many as the gold standard for comparison of implants due to its extensive documentation. 150 patients with a mean age of 70 years were randomized, single-blinded, to receive either a cemented Charnley flanged 40 monoblock, stainless steel, vaquasheen surface femoral stem with a 22.2-mm head (n = 30) or a cemented Spectron EF modular, matte, straight, collared, cobalt-chrome femoral stem with a 28-mm femoral head and a roughened proximal third of the stem (n = 120). The patients were followed with repeated radiostereometric analysis for 2 years to assess migration. At 2 years, stem retroversion was 2.3° and 0.7° (p < 0.001) and posterior translation was 0.44 mm and 0.17 mm (p = 0.002) for the Charnley group (n = 26) and the Spectron EF group (n = 74), respectively. Subsidence was 0.26 mm for the Charnley and 0.20 mm for the Spectron EF (p = 0.5). The Spectron EF femoral stem was more stable than the Charnley flanged 40 stem in our study when evaluated at 2 years. In a report from the Norwegian arthroplasty register, the Spectron EF stem had a higher revision rate due to aseptic loosening beyond 5 years than the Charnley. Initial stability is not invariably related to good long-term results. Our results emphasize the importance of prospective long-term follow-up of prosthetic implants in clinical trials and national registries and a stepwise introduction of implants.

  3. Factors affecting the aluminium content of human femoral head and neck.

    Science.gov (United States)

    Zioła-Frankowska, Anetta; Dąbrowski, Mikołaj; Kubaszewski, Łukasz; Rogala, Piotr; Frankowski, Marcin

    2015-11-01

    Tissues for the study were obtained intraoperatively during hip replacement procedures from 96 patients. In all the cases, the indication for this treatment was primary or secondary degenerative changes in the hip joint. The subject of the study was the head and neck of the femur, resected in situ. Aluminium concentrations measured in femoral head and neck samples from patients aged between 25 and 91 were varied. Statistical methods were applied to determine the variations in relation to the parameters from the background survey. Significant differences in the aluminium content of femoral head samples were observed between patients under and over 60 years of age. Based on the results, it was confirmed that the aluminium accumulates in bones over a lifetime. The study showed that the content of aluminium in the head and neck of the femur depends on the factors such as: type of medicines taken, contact with chemicals at work, differences in body anatomy and sex. The study on the levels of aluminium in bones and the factors affecting its concentration is a valuable source of information for further research on the role of aluminium in bone diseases. Based on the investigations, it was found that the GF-AAS technique is the best analytical tool for routine analysis of aluminium in complex matrix samples. The use of femoral heads in the investigations was approved by the Bioethics Committee of the University of Medical Sciences in Poznań (Poland). Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Total resection of any segment of the lateral meniscus may cause early cartilage degeneration: Evaluation by magnetic resonance imaging using T2 mapping.

    Science.gov (United States)

    Murakami, Koji; Arai, Yuji; Ikoma, Kazuya; Kato, Kammei; Inoue, Hiroaki; Nakagawa, Shuji; Fujii, Yuta; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2018-06-01

    The aim of this study was to perform quantitative evaluation of degeneration of joint cartilage using T2 mapping in magnetic resonance imaging (MRI) after arthroscopic partial resection of the lateral meniscus.The subjects were 21 patients (23 knees) treated with arthroscopic partial resection of the lateral meniscus. MRI was performed for all knees before surgery and 6 months after surgery to evaluate the center of the lateral condyle of the femur in sagittal images for T2 mapping. Ten regions of interest (ROIs) on the articular cartilage were established at 10-degree intervals, from the point at which the femur shaft crossed the lateral femoral condyle joint to the articular cartilage 90° relative to the femur shaft. Preoperative and postoperative T2 values were evaluated at each ROI. Age, sex, body mass index, femorotibial angle, Tegner score, and amount of meniscal resection were evaluated when the T2 value increased more than 6% at 30°.T2 values at approximately 10 °, 20 °, 30 °, 40 °, 50 °, and 60 ° degrees relative to the anatomical axis of the femur were significantly greater postoperatively (3.1, 3.6, 5.5, 4.4, 5.0, 6.4%, respectively) than preoperatively. A >6% increase at 30° was associated with total resection of any segment of the meniscus.Degeneration of the articular cartilage, as shown by the disorganization of collagen arrays at positions approximately 10 °, 20 °, 30 °, 40 °, 50 °, and 60 ° relative to the anatomical axis of the femur, may start soon after arthroscopic lateral meniscectomy. Total resection of any segment of the lateral meniscus may cause T2 elevation of articular cartilage of lateral femoral condyle.

  5. Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions.

    Science.gov (United States)

    Osman, K; Panagiotidou, A P; Khan, M; Blunn, G; Haddad, F S

    2016-05-01

    There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice. Cite this article: Bone Joint J 2016;98-B:579-84. ©2016 The British Editorial Society of Bone & Joint Surgery.

  6. Bilateral stress fractures of femoral neck in non-athletes: a report of four cases

    Directory of Open Access Journals (Sweden)

    Naik Monappa A

    2013-04-01

    Full Text Available 【Abstract】Femoral neck stress fractures (FNSFs are rare, constituting only 5% of all stress fractures in young adults. These fractures are usually seen in athletes, military recruits and patients with underlying metabolic diseases. The treatment of FNSFs is still controversial because of the inherent complications associated with the treatment procedure. We came across 4 cases of bilateral FNSFs in non-athletic individuals who were manual labourers with-out underlying bony disorders. Two patients with FNSFs and coxa vara deformity on both sides were managed by subtrochanteric valgus osteotomy and dynamic hip screw fixation. One of the remaining two patients was treated by cannulated cancellous screw fixation on one side and sub-trochanteric valgus osteotomy on the other side. The fourth patient received subtrochanteric valgus osteotomy on one side and bipolar hemiarthroplasty on the other side after failed cannulated screw fixation. All the fractures healed without any complications. No evidence of avascular ne-crosis or arthritis was noted in our series. Subtrochanteric valgus osteotomy restores normal neck-shaft angle in pa-tients suffering from FNSFs combined with coxa vara deformity. Moreover, it helps to bring the forces acting around the hip to normal biomechanical levels, leading to fracture union and better results. Replacement arthroplasty is recommended to patients who fail to achieve bony union after fixation. Key words: Fractures, stress; Femoral neck fractures; Coxa vara; Osteotomy

  7. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  8. A numerical investigation into the influence of the properties of cobalt chrome cellular structures on the load transfer to the periprosthetic femur following total hip arthroplasty.

    Science.gov (United States)

    Hazlehurst, Kevin Brian; Wang, Chang Jiang; Stanford, Mark

    2014-04-01

    Stress shielding of the periprosthetic femur following total hip arthroplasty is a problem that can promote the premature loosening of femoral stems. In order to reduce the need for revision surgery it is thought that more flexible implant designs need to be considered. In this work, the mechanical properties of laser melted square pore cobalt chrome molybdenum cellular structures have been incorporated into the design of a traditional monoblock femoral stem. The influence of incorporating the properties of cellular structures on the load transfer to the periprosthetic femur was investigated using a three dimensional finite element model. Eleven different stiffness configurations were investigated by using fully porous and functionally graded approaches. This investigation confirms that the periprosthetic stress values depend on the stiffness configuration of the stem. The numerical results showed that stress shielding is reduced in the periprosthetic Gruen zones when the mechanical properties of cobalt chrome molybdenum cellular structures are used. This work identifies that monoblock femoral stems manufactured using a laser melting process, which are designed for reduced stiffness, have the potential to contribute towards reducing stress shielding. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

    Science.gov (United States)

    Hambright, D; Hellman, M; Barrack, R

    2018-01-01

    The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36-43. ©2018 The British Editorial Society of Bone & Joint Surgery.

  10. [Effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early osteonecrosis of the femoral head].

    Science.gov (United States)

    Li, Ji; Li, Zhongli; Su, Xiangzheng; Liu, Chunhui; Zhang, Hao; Wang, Ketao

    2017-09-01

    To evaluate the effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early oeteonecrosis of the femoral head (ONFH). Between March 2010 and December 2013, 91 patients with early ONFH were treated with the operation of multiple small-diameter drilling decompression combined with hip arthroscopy in 39 cases (53 hips, group A) or with drilling decompression alone in 52 cases (74 hips, group B). The patients in 2 groups had obvious hip pain and limited motion before operation. There was no significant difference in gender, age, etiology, effected side, stage of osteonecrosis, and preoperative Harris score between 2 groups ( P >0.05). All operations succeeded and all incisions healed by first intention. The operation time was significantly longer in group A [(73.3±10.6) minutes] than in group B [(41.5±7.2) minutes] ( t =8.726, P =0.000). Temporary of sciatic nerve apraxia after operation occurred in 2 patients of group A, and no complication occurred in other patients. Patients were followed up 24-52 months (mean, 39.3 months) in group A and 24-48 months (mean, 34.6 months) in group B. At last follow-up, the Harris scores were 83.34±8.76 in group A and 76.61±9.22 in group B, showing significant differences when compared between 2 groups ( t =-4.247, P =0.029) and when compared with preoperative values in 2 groups ( t =-10.327, P =0.001; t =-8.216, P =0.008). X-ray films showed that the collapse of the femoral head was observed in 6 hips (1 hip at stage Ⅰand 5 hips at stage Ⅱ) in group A, and in 16 hips (4 hips at stageⅠand 12 hips at stage Ⅱ) in group B; and hip arthroplasty was performed. The total effective rates were 88.68% (47/53) in group A and 78.38% (58/74) in group B, respectively; showing significant difference between 2 groups ( χ 2 =5.241, P =0.041). Multiple small-diameter drilling decompression combined with hip arthroscopy is effective in pain relief, improvement of hip function, slowing-down the

  11. Correlation of ultrasound appearance, gross anatomy, and histology of the femoral nerve at the femoral triangle.

    Science.gov (United States)

    Lonchena, Tiffany K; McFadden, Kathryn; Orebaugh, Steven L

    2016-01-01

    Correlation between ultrasound appearance, gross anatomic characteristics, and histologic structure of the femoral nerve (FN) is lacking. Utilizing cadavers, we sought to characterize the anatomy of the FN, and provide a quantitative measure of its branching. We hypothesize that at the femoral crease, the FN exists as a group of nerve branches, rather than a single nerve structure, and secondarily, that this transition into many branches is apparent on ultrasonography. Nineteen preserved cadavers were investigated. Ultrasonography was sufficient to evaluate the femoral nerve in nine specimens; gross dissection was utilized in all 19. Anatomic characteristics were recorded, including distances from the inguinal ligament to femoral crease, first nerve branch, and complete arborization of the nerve. The nerves from nine specimens were excised for histologic analysis. On ultrasound, the nerve became more flattened, widened, and less discrete as it coursed distally. Branching of the nerve was apparent in 12 of 18 images, with mean distance from inguinal ligament of 3.9 (1.0) cm. However, upon dissection, major branching of the femoral nerve occurred at 3.1 (1.0) cm distal to the inguinal ligament, well proximal to the femoral crease. Histologic analysis was consistent with findings at dissection. The femoral nerve arborizes into multiple branches between the inguinal ligament and the femoral crease. Initial branching is often high in the femoral triangle. As hypothesized, the FN exists as a closely associated group of nerve branches at the level of the femoral crease; however, the termination of the nerve into multiple branches is not consistently apparent on ultrasonography.

  12. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.

    Science.gov (United States)

    Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L

    2016-10-01

    The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Subtrochanteric femoral fracture during trochanteric nailing for the treatment of femoral shaft fracture.

    Science.gov (United States)

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-09-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nailing for femoral shaft fractures to improve its application and prevent implant-derived complications.

  14. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    Science.gov (United States)

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (Pcup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Hemoglobin to Hematocrit Ratio: The Strongest Predictor of Femoral Head Osteonecrosis in Children With Sickle Cell Disease.

    Science.gov (United States)

    Worrall, Douglas; Smith-Whitley, Kim; Wells, Lawrence

    2016-03-01

    Femoral head osteonecrosis (ON) secondary to sickle cell disease (SCD) often progresses to femoral head collapse, requiring total hip arthroplasty. However, this treatment has a limited durability and patients with SCD have higher rates of complications, requiring multiple revision operations. Identifying risk factors linked to ON in SCD can facilitate earlier precollapse diagnosis and surgical treatment aimed at preservation of the native hip joint. Fifty-nine children treated at our institution between January 2001 and April 2012 with SCD and ON, as diagnosed by magnetic resonance imaging or radiographic imaging, were compared with age-matched and sickle cell phenotype-matched (SS, SC, Sβ, Sβ) controls with no evidence of ON. Two sided t-tests assuming unequal variances determined statistically risk factors and threshold values were assigned to calculate odds ratios. Systolic blood pressure (P=1.2×10, OR=3.68), diastolic blood pressure (P=0.0084, OR=1.41), weight in the SCD-SS population (P=0.04, OR=1.85), and hemoglobin (Hb) in the SCD-SS population (P=0.036, OR=2.56) were elevated in cases. Curiously, dividing the Hb by the hematocrit to serve as a clinical proxy for the mean corpuscular Hb concentration (MCHC) produced an excellent predictor of ON (P=2.06×10, OR=5.17), which was especially pronounced in the SCD-SS subpopulation (P=2.28×10, OR=8.65). Among children with SCD, the overall prevalence of ON was 9% (59/658) and the phenotype with the highest prevalence of ON was Sβ thalassemia with an ON prevalence of 11.1%. There was no observed correlation between ON and height, body mass index, cholesterol, mean corpuscular volume, hematocrit, or glucocorticoid use. These data support a novel clinical marker, the MCHC proxy, as the strongest predictor of ON in children with SCD. High-risk children should receive hip magnetic resonance imaging to diagnose early ON and facilitate interventions focused on hip preservation, forestalling, or possibly preventing

  16. Transfemoral amputation after failure of knee arthroplasty

    DEFF Research Database (Denmark)

    Gottfriedsen, Tinne B; Morville Schrøder, Henrik; Odgaard, Anders

    2016-01-01

    BACKGROUND: Transfemoral amputation is considered the last treatment option for failed knee arthroplasty. The extent to which this procedure is performed is not well known. The purpose of this study was to identify the incidence and causes of amputation following failure of knee arthroplasty...... were followed by amputation. Hospital records of all identified cases were reviewed. A competing-risk model was used to estimate the cumulative incidence of amputation. Differences in cumulative incidences were analyzed with use of the Gray test. RESULTS: A total of 115 amputations were performed...... for causes related to failed knee arthroplasty. The 15-year cumulative incidence of amputation was 0.32% (95% confidence interval [CI], 0.23% to 0.48%). The annual incidence of amputation following arthroplasties performed from 1997 to 2002 was 0.025% compared with 0.018% following arthroplasties performed...

  17. Knee Arthrodesis After Failure of Knee Arthroplasty

    DEFF Research Database (Denmark)

    Gottfriedsen, Tinne B; Morville Schrøder, Henrik; Odgaard, Anders

    2016-01-01

    BACKGROUND: Arthrodesis is considered a salvage procedure after failure of a knee arthroplasty. Data on the use of this procedure are limited. The purpose of this study was to identify the incidence, causes, surgical techniques, and outcomes of arthrodesis after failed knee arthroplasty...... in a nationwide population. METHODS: Data were extracted from the Danish Civil Registration System, the Danish National Patient Register, and the Danish Knee Arthroplasty Register. A total of 92,785 primary knee arthroplasties performed in Denmark from 1997 to 2013 were identified by linking the data using....... Differences in cumulative incidence were compared with the Gray test. RESULTS: A total of 164 of the 165 arthrodeses were performed for causes related to failed knee arthroplasty. The 15-year cumulative incidence of arthrodesis was 0.26% (95% confidence interval, 0.21% to 0.31%). The 5-year cumulative...

  18. Return to sports after shoulder arthroplasty

    Science.gov (United States)

    Johnson, Christine C; Johnson, Daniel J; Liu, Joseph N; Dines, Joshua S; Dines, David M; Gulotta, Lawrence V; Garcia, Grant H

    2016-01-01

    Many patients prioritize the ability to return to sports following shoulder replacement surgeries, including total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA), and hemiarthroplasty (HA). While activity levels after hip and knee replacements have been well-established in the literature, studies on this topic in the field of shoulder arthroplasty are relatively limited. A review of the literature regarding athletic activity after shoulder arthroplasty was performed using the PubMed database. All studies relevant to shoulder arthroplasty and return to sport were included. The majority of patients returned to their prior level of activity within six months following TSA, RTSA, and shoulder HA. Noncontact, low demand activities are permitted by most surgeons postoperatively and generally have higher return rates than contact sports or high-demand activities. In some series, patients reported an improvement in their ability to participate in sports following the arthroplasty procedure. The rates of return to sports following TSA (75%-100%) are slightly higher than those reported for HA (67%-76%) and RTSA (75%-85%). Patients undergoing TSA, RTSA, and shoulder HA should be counseled that there is a high probability that they will be able to return to their preoperative activity level within six months postoperatively. TSA has been associated with higher rates of return to sports than RTSA and HA, although this may reflect differences in patient population or surgical indication. PMID:27672564

  19. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  20. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    Science.gov (United States)

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-11-01

    PEEK-OPTIMA ™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA ™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA ™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm 3 /million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm 3 /million cycles and 2.44 ± 0.78 mm 3 /million cycle against cobalt chrome and PEEK-OPTIMA ™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm 3 /million cycles and 4.44 ± 2.35 mm 3 /million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA ™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA ™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of

  2. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These

  3. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  4. Clinical outcome after treatment of infected primary total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jensen, Tim Toftgaard

    2002-01-01

    Twenty-six consecutive cases of infected primary total knee arthroplasties were treated at our institution from 1989 through 2000. Eleven patients had debridement and irrigation performed within 2 months of index arthroplasty or hematogenous spread; only one infection was eradicated. Twenty......-five patients had their prostheses removed; 17 had two-stage revision arthroplasty, following which infection was eradicated in 15; one had a permanent spacer, 7 had arthrodesis (following failed revision arthroplasty in one) and 2 had a femur amputation (following failed revision arthroplasty in one) at follow......-up of mean 24 months. Infections were cured equally well with revision arthroplasty and arthrodesis. Among the 15 patients who ended up with revision arthroplasty, 11 had a better range of motion compared to the index arthroplasty, but 8 had daily pain. We present our treatment protocol, which eradicated 15...

  5. One-stage versus two-stage exchange arthroplasty for infected total knee arthroplasty: a systematic review.

    Science.gov (United States)

    Nagra, Navraj S; Hamilton, Thomas W; Ganatra, Sameer; Murray, David W; Pandit, Hemant

    2016-10-01

    Infection complicating total knee arthroplasty (TKA) has serious implications. Traditionally the debate on whether one- or two-stage exchange arthroplasty is the optimum management of infected TKA has favoured two-stage procedures; however, a paradigm shift in opinion is emerging. This study aimed to establish whether current evidence supports one-stage revision for managing infected TKA based on reinfection rates and functional outcomes post-surgery. MEDLINE/PubMed and CENTRAL databases were reviewed for studies that compared one- and two-stage exchange arthroplasty TKA in more than ten patients with a minimum 2-year follow-up. From an initial sample of 796, five cohort studies with a total of 231 patients (46 single-stage/185 two-stage; median patient age 66 years, range 61-71 years) met inclusion criteria. Overall, there were no significant differences in risk of reinfection following one- or two-stage exchange arthroplasty (OR -0.06, 95 % confidence interval -0.13, 0.01). Subgroup analysis revealed that in studies published since 2000, one-stage procedures have a significantly lower reinfection rate. One study investigated functional outcomes and reported that one-stage surgery was associated with superior functional outcomes. Scarcity of data, inconsistent study designs, surgical technique and antibiotic regime disparities limit recommendations that can be made. Recent studies suggest one-stage exchange arthroplasty may provide superior outcomes, including lower reinfection rates and superior function, in select patients. Clinically, for some patients, one-stage exchange arthroplasty may represent optimum treatment; however, patient selection criteria and key components of surgical and post-operative anti-microbial management remain to be defined. III.

  6. Early results of metal on metal articulation total hip arthroplasty in young patients.

    Science.gov (United States)

    Mohamad, J A; Kwan, M K; Merican, A M; Abbas, A A; Kamari, Z H; Hisa, M K; Ismail, Z; Idrus, R M

    2004-12-01

    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.

  7. Self-designed femoral neck guide pin locator for femoral neck fractures.

    Science.gov (United States)

    Xia, Shengli; Wang, Ziping; Wang, Minghui; Wu, Zuming; Wang, Xiuhui

    2014-01-01

    Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

  8. The use of allograft bone during the course of femoral reconstruction in hip revision arthroplasty

    International Nuclear Information System (INIS)

    David, A.; Morgan, F.; Imran Ilyas

    1999-01-01

    We have studied 61 patients who underwent femoral revision surgery requiring allograft reconstruction of the skeleton between 1987 and 1995. The group had a mean age of 68 years with a mean follow-up of 5.1 years. The preoperative Harris hip score was increased from 30 points to a postoperative score of 69 points. A rerevision rate of 20% was noted. Segmental anomalies were classified according to the American Academy of Orthopaedic Surgeons system. Subgroups were analysed according to the classification and relative indications for the use of impaction allografting, corticocancellous strut grafting, anatomic specific allografts and calcar allografts were devised. This paper details the results of those subgroups and outlines pitfalls and problems associated with complex surgery of this type

  9. Robotics in Arthroplasty: A Comprehensive Review.

    Science.gov (United States)

    Jacofsky, David J; Allen, Mark

    2016-10-01

    Robotic-assisted orthopedic surgery has been available clinically in some form for over 2 decades, claiming to improve total joint arthroplasty by enhancing the surgeon's ability to reproduce alignment and therefore better restore normal kinematics. Various current systems include a robotic arm, robotic-guided cutting jigs, and robotic milling systems with a diversity of different navigation strategies using active, semiactive, or passive control systems. Semiactive systems have become dominant, providing a haptic window through which the surgeon is able to consistently prepare an arthroplasty based on preoperative planning. A review of previous designs and clinical studies demonstrate that these robotic systems decrease variability and increase precision, primarily focusing on component positioning and alignment. Some early clinical results indicate decreased revision rates and improved patient satisfaction with robotic-assisted arthroplasty. The future design objectives include precise planning and even further improved consistent intraoperative execution. Despite this cautious optimism, many still wonder whether robotics will ultimately increase cost and operative time without objectively improving outcomes. Over the long term, every industry that has seen robotic technology be introduced, ultimately has shown an increase in production capacity, improved accuracy and precision, and lower cost. A new generation of robotic systems is now being introduced into the arthroplasty arena, and early results with unicompartmental knee arthroplasty and total hip arthroplasty have demonstrated improved accuracy of placement, improved satisfaction, and reduced complications. Further studies are needed to confirm the cost effectiveness of these technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Prediction of traumatic avascular necrosis of the femoral head by single photon emission computerized tomography and computerized tomography: an experimental study in dogs

    Directory of Open Access Journals (Sweden)

    SHEN Feng

    2012-02-01

    Full Text Available 【Abstract】 Objective: To evaluate the femoral head perfusion and to predict the traumatic avascular necrosis (AVN of the femoral head by single photon emission computerized tomography and computerized tomography (SPECT/CT. Methods: Totally 18 adult beagle dogs were divided randomly into three equal-sized (n=6 groups. Subsequently different degrees of ischemia model were developed by destroying blood vessels of the femoral head. The left hip received sham operation as normal control and the right hip underwent blood interruption. In Group A, the ligamentum teres was cut off. In Group B, the marrow cavity of the right femoral neck was destroyed while in Group C, the soft tissues at the base of the femoral neck were stripped in addition to the resection of the ligamentum teres and destruction of the marrow cavity. Three hours after surgery, SPECT/CT was performed. Laser Doppler Flowmetry (LDF measurements were also obtained at three different time points (before operation, immediately and three hours after operation in order to assess the change process of blood supply to the femoral head. Results: SPECT/CT showed no significant difference in the radionuclide uptake between the right and left femoral heads in Group A (t=-0.09, P=0.94 and Group B (t= 0.52, P=0.62. However, in Group C, it was 261±62 for the right femoral head, only 12% of that in the left femoral head. LDF measurements indicated that the femoral head perfusion was decreased from (45.0±3.3 PU to (39.1±3.7 PU in Group A, from (44.0±2.7 PU to (34.3±2.6 PU in Group B, and from (47.3±2.1 PU to (4.96±0.6 PU in Group C immediately after operation. However, the perfusion was restored and returned to normal values three hours after operation except in Group C. Conclusion: SPECT/CT could assess the perfusion of the femoral head semiquantitatively, which might be useful in predicting the development of traumatic AVN. Key words: Femur head necrosis; Femoral head; Tomography, emission

  11. Imaging of knee arthroplasty

    International Nuclear Information System (INIS)

    Miller, Theodore T.

    2005-01-01

    Knee replacement surgery, either with unicompartmental or total systems, is common. The purpose of this manuscript is to review the appearance of normal knee arthroplasty and the appearances of complications such as infection, polyethylene wear, aseptic loosening and particle-induced osteolysis, patellofemoral abnormalities, axial instability, and periprosthetic and component fracture. Knowledge of the potential complications and their imaging appearances will help the radiologist in the diagnostic evaluation of the patient with a painful knee arthroplasty

  12. Imaging of knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T. [Department of Radiology, North Shore University Hospital, 825 Northern Blvd., Great Neck, NY 11021 (United States)]. E-mail: TMiller@NSHS.edu

    2005-05-01

    Knee replacement surgery, either with unicompartmental or total systems, is common. The purpose of this manuscript is to review the appearance of normal knee arthroplasty and the appearances of complications such as infection, polyethylene wear, aseptic loosening and particle-induced osteolysis, patellofemoral abnormalities, axial instability, and periprosthetic and component fracture. Knowledge of the potential complications and their imaging appearances will help the radiologist in the diagnostic evaluation of the patient with a painful knee arthroplasty.

  13. Effect of limb rotation on radiographic alignment in total knee arthroplasties.

    Science.gov (United States)

    Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven

    2010-04-01

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic alignment after TKA and to establish a re-calculation of this rotation by using existing radiographic landmarks. Synthetic femur and tibia (Sawbones), Inc. Vashon Island, WA) were used to create a TKA of the Triathlon knee prosthesis system (Stryker), Limerick, Ireland). The femoral alignment was 6.5 degrees valgus. The model was fixed in an upright stand. Five series of nine anteroposterior (AP) long leg radiographs were taken on a 30 cm x 120 cm plates in full extension with the limb rotated, in 5 degrees increments, from 20 degrees external rotation to 20 degrees internal rotation. After digitizing each radiograph (Scanner Hewlett Packard XJ 527), an observer measured the anatomic mechanical angle of the femur [AMA ( degrees )], the mechanical lateral proximal femur angle [mLPFA ( degrees )], the mechanical lateral distal femur angle [mLDFA ( degrees )], the mechanical medial proximal tibia angle [mMPTA ( degrees )] and the mechanical lateral distal tibia angle [mLDTA ( degrees )] using a digital measurement software (MediCAD, Hectec, Altfraunhofen, Germany). Besides, the observer measured the geometrical distances of the femoral component figured on the long leg radiograph. A ratio of one distance to another was measured (called femoral component distance ratio). The average radiographic anatomic alignment ranged from 6.827 degrees AMA (SD = 0.22 degrees ) in 20 degrees internal rotation to 4.627 degrees AMA (SD = 0.22 degrees ) in 20 degrees external rotation. Average mLPFA ( degrees ) ranged from 101.63 degrees (SD = 0.63) in 20 degrees internal rotation to 93.60 degrees (SD = 0.74 degrees ) in 20 degrees external rotation. Average mLDFA ( degrees ) ranged from 90.59 degrees

  14. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  15. Comparison of Radial Access, Guided Femoral Access, and Non-Guided Femoral Access Among Women Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Koshy, Linda M; Aberle, Laura H; Krucoff, Mitchell W; Hess, Connie N; Mazzaferri, Ernest; Jolly, Sanjit S; Jacobs, Alice; Gibson, C Michael; Mehran, Roxana; Gilchrist, Ian C; Rao, Sunil V

    2018-01-01

    This study was conducted to determine the association between radial access, guided femoral access, and non-guided femoral access on postprocedural bleeding and vascular complications after percutaneous coronary intervention (PCI). Bleeding events and major vascular complications after PCI are associated with increased morbidity, mortality, and cost. While the radial approach has been shown to be superior to the femoral approach in reducing bleeding and vascular complications, whether the use of micropuncture, fluoroscopy, or ultrasound mitigates these differences is unknown. We conducted a post hoc analysis of women in the SAFE-PCI for Women trial who underwent PCI and had the access method identified (n = 643). The primary endpoint of postprocedure bleeding or vascular complications occurring within 72 hours or at discharge was adjudicated by an independent clinical events committee and was compared based on three categories of access technique: radial, guided femoral (fluoroscopy, micropuncture, ultrasound), or non-guided femoral (none of the aforementioned). Differences between the groups were determined using multivariate logistic regression using radial access as the reference. Of the PCI population, 330 underwent radial access, 228 underwent guided femoral access, and 85 underwent non-guided femoral access. There was a statistically significant lower incidence of the primary endpoint with radial access vs non-guided femoral access; however, there was no significant difference between radial approach and femoral access guided by fluoroscopy, micropuncture, or ultrasound. This post hoc analysis demonstrates that while radial access is safer than non-guided femoral access, guided femoral access appears to be associated with similar bleeding events or vascular complications as radial access.

  16. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review.

    Science.gov (United States)

    Yan, Shuang G; Weber, Patrick; Steinbrück, Arnd; Hua, Xingyi; Jansson, Volkmar; Schmidutz, Florian

    2017-11-27

    Short-stem hip arthroplasty (SHA) was designed to preserve bone stock and provide an improved load transfer. To gain more evidence regarding the load transfer, this review analysed the periprosthetic bone remodelling of SHA in comparison to standard hip arthroplasty (THA). PubMed and ScienceDirect were screened to extract dual-energy X-ray absorptiometry (DXA) studies evaluating the periprosthetic bone remodelling of SHA and two proven THA designs. From the studies included, the postoperative change in periprosthetic bone mineral density (BMD) after one year and the trend over two years was determined. Fifteen studies with four SHAs (CFP, Metha, Nanos, Fitmore) and two THAs (CLS and Bicontact) designs were included. All SHA and THA stems revealed an initial decrease at the calcar and major trochanter (Gruen 1 and 7) with the Metha, Nanos and Fitmore showing a smaller and more balanced remodelling compared to THA. The pattern after one year and the trend over two years argue for a methaphyseal anchorage of the Metha and Nanos, whereas the Fitmore and CFP seem to anchor metha-diaphyseal. Clearly different pattern of bone remodelling were observed between all four SHAs. Periprosthetic bone remodelling is also present in SHA, with the main bone reduction observed proximally. However, certain SHA stems show a more balanced remodelling compared to THA, arguing for a favourable load transfer. Also, the femoral length where bone remodelling occurs is clearly shorter in SHA. As distinctively different pattern between the SHA designs were observed, they should not be judged as a single implant group.

  17. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  18. Hip arthroplasty in failed intertrochanteric fractures in elderly

    Directory of Open Access Journals (Sweden)

    Javahir A Pachore

    2013-01-01

    Full Text Available Background: Failed intertrochanteric fractures in elderly patients are surgical challenge with limited options. Hip arthroplasty is a good salvage procedure even though it involves technical issues such as implant removal, bone loss, poor bone quality, trochanteric nonunion and difficulty of surgical exposure. Materials and Methods: 30 patients of failed intertrochanteric fractures where hip arthroplasty was done between May 2008 and December 2011 were included in study. 13 were males and 17 were females with average age of 67.3 years. There were 2 cemented bipolar arthroplasties, 19 uncemented bipolar, 4 cemented total hip arthroplasty and 5 uncemented total hip arthroplasties. 16 patients had a trochanteric nonunion, which was treated by tension band principles. Total hip was considered where there was acetabular damage due to the penetration of implant. Results: The average followup was 20 months (range 6-48 months. Patients were followed up from 6 to 48 months with average followup of 20 months. None of the patients were lost to followup. There was no dislocation. All patients were ambulatory at the final followup. Conclusion: A predictable functional outcome can be achieved by hip arthroplasty in elderly patients with failed intertrochanteric fractures. Though technically demanding, properly performed hip arthroplasty can be a good salvage option for this patient group.

  19. Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process

    Directory of Open Access Journals (Sweden)

    Robert P. Runner, MD

    2017-06-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.

  20. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rolfson, Ola; Rubash, Harry E

    2016-01-01

    BACKGROUND: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS: Forty-seven patients (51 hips...... year remain stable at 5 years. RSA was the most sensitive method of detection for stems at greater risk for potential future failure. This report adds contributions to the positive results associated with this type of fixation. The results at 5 years showed excellent midterm survivorship in this cohort...

  1. Treatment of osteonecrosis of the femoral head by free vascularized fibular grafting: an analysis of surgical outcome and patient health status

    Science.gov (United States)

    Louie, Brian E.; McKee, Michael D.; Richards, Robin R.; Mahoney, James L.; Waddell, James P.; Beaton, Dorcas E.; Schemitsch, Emil H.; Yoo, Daniel J.

    1999-01-01

    Objective To evaluate the limb-specific outcome and general health status of patients with osteonecrosis of the femoral head treated with vascularized fibular grafting. Design A retrospective review. Setting A single tertiary care centre. Patients Fifty-five consecutive patients with osteonecrosis of the femoral head who underwent fibular grafting (8 bilaterally). Intervention Vascularized fibular grafting. Outcome measures Limb-specific scores (Harris Hip Score, St. Michael’s Hospital Hip Score), general health status (Nottingham Health Profile, SF-36 health status survey) and radiographic outcome measures (Steinberg stage). Results Patients were young (mean age 34 years, range from 18 to 52 years) and 80% had advanced osteonecrosis (Steinberg stages IV and V). Fifty-nine hips were followed up for an average of 50 months (range from 24 to 117 months) after vascularized fibular grafting. Sixteen hips (27%) were converted to total hip arthroplasty (THA). To date, 73% of hips treated with vascularized fibular grafting have required no further surgery. Preoperative and postoperative Harris Hip Scores were 57.3 and 83.6 respectively (p < 0.001). As measured by patient-oriented health status questionnaires (SF-36, Nottingham Health Profile) and compared with population controls, patients had normal mental health scores and only slight decreases in physical component scores. Conclusions Free vascularized fibular grafting for osteonecrosis of the femoral head provides satisfactory pain relief, functional improvement and general health status and halts the progression of symptomatic disease. PMID:10459327

  2. Long-term outcomes of patellofemoral arthroplasty.

    NARCIS (Netherlands)

    Jonbergen, J.P.W. van; Werkman, D.M.; Barnaart, L.F.; Kampen, A. van

    2010-01-01

    The purpose of this study was to correlate the long-term survival of patellofemoral arthroplasty with primary diagnosis, age, sex, and body mass index. One hundred eighty-five consecutive Richards type II patellofemoral arthroplasties were performed in 161 patients with isolated patellofemoral

  3. Evaluation of a pig femoral head osteonecrosis model

    Directory of Open Access Journals (Sweden)

    Kim Harry

    2010-03-01

    Full Text Available Abstract Background A major cause of osteonecrosis of the femoral head is interruption of a blood supply to the proximal femur. In order to evaluate blood circulation and pathogenetic alterations, a pig femoral head osteonecrosis model was examined to address whether ligature of the femoral neck (vasculature deprivation induces a reduction of blood circulation in the femoral head, and whether transphyseal vessels exist for communications between the epiphysis and the metaphysis. We also tested the hypothesis that the vessels surrounding the femoral neck and the ligamentum teres represent the primary source of blood flow to the femoral head. Methods Avascular osteonecrosis of the femoral head was induced in Yorkshire pigs by transecting the ligamentum teres and placing two ligatures around the femoral neck. After heparinized saline infusion and microfil perfusion via the abdominal aorta, blood circulation in the femoral head was evaluated by optical and CT imaging. Results An angiogram of the microfil casted sample allowed identification of the major blood vessels to the proximal femur including the iliac, common femoral, superficial femoral, deep femoral and circumflex arteries. Optical imaging in the femoral neck showed that a microfil stained vessel network was visible in control sections but less noticeable in necrotic sections. CT images showed a lack of microfil staining in the epiphysis. Furthermore, no transphyseal vessels were observed to link the epiphysis to the metaphysis. Conclusion Optical and CT imaging analyses revealed that in this present pig model the ligatures around the femoral neck were the primary cause of induction of avascular osteonecrosis. Since the vessels surrounding the femoral neck are comprised of the branches of the medial and the lateral femoral circumflex vessels, together with the extracapsular arterial ring and the lateral epiphyseal arteries, augmentation of blood circulation in those arteries will improve

  4. A protocol avoiding allogeneic transfusion in joint arthroplasties.

    Science.gov (United States)

    Suh, You-Sung; Nho, Jae-Hwi; Choi, Hyung-Suk; Ha, Yong-Chan; Park, Jong-Seok; Koo, Kyung-Hoi

    2016-09-01

    Arthroplasties of hip and knee are associated with blood loss, which may lead to adverse patient outcome. Performing arthroplasties in Jehovah's Witness patients who do not accept transfusion has been a matter of concern. We developed a protocol, which avoids transfusion in arthroplasties of Jehovah's Witness patients, and evaluated the feasibility and safety of the protocol. The target of preoperative hemoglobin was more than 10 g/dL. When preoperative hemoglobin was lower than 10 g/dL, 4000 U erythropoietin (3 times a week) and 100 mg iron supplement (every day) were administered until the hemoglobin reached 10 g/dL. When the preoperative hemoglobin was higher than 10 g/dL, 4000 U erythropoietin and 100 mg iron supplement were administered once, before operation. During the operation, cell saver was used. Postoperatively, erythropoietin and iron supplements were administered until the hemoglobin reached 10 g/dL, similar to the preoperative protocol. We evaluated the feasibility of our protocol, perioperative complications and hematologic changes. From 2002 to 2014, 186 Witness patients visited our department. In 179 patients (96.2 %), 77 total knee arthroplasties, 69 bipolar hemiarthroplasties and 33 total hip arthroplasties were performed. The mean hemoglobin level was 12.3 g/dL preoperatively, 9.4 g/dL on postoperative day 3 and 10.3 g/dL on postoperative day 7. One patient died immediately after the arthroplasty and the remaining 178 patients survived. Total joint arthroplasty could be done without transfusion using this protocol in most of our patients. The rates of infection and mortality were similar with known infection and mortality rates of arthroplasties. In patients who do not want allogeneic transfusions, our protocol is a safe alternative to perform joint arthroplasties.

  5. Cervical disc arthroplasty: Pros and cons.

    Science.gov (United States)

    Moatz, Bradley; Tortolani, P Justin

    2012-01-01

    Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing.

  6. Cryotherapy on postoperative rehabilitation of joint arthroplasty.

    Science.gov (United States)

    Ni, Sheng-Hui; Jiang, Wen-Tong; Guo, Lei; Jin, Yu-Heng; Jiang, Tian-Long; Zhao, Yuyan; Zhao, Jie

    2015-11-01

    The effectiveness of cryotherapy on joint arthroplasty recovery remains controversial. This systematic review was conducted to assess the effectiveness of cryotherapy in patients after joint arthroplasty. Comprehensive literature searches of several databases including Cochrane Library (2013), MEDLINE (1950-2013), and Embase (1980-2013) were performed. We sought randomised controlled trials that compared the experimental group received any form of cryotherapy with any control group after joint arthroplasty. The main outcomes were postoperative blood loss, adverse events, and pain. Analyses were performed with Revman 5.0. Results were shown as mean differences (MD) and standard deviations or as risk difference and 95 % confidence intervals (CIs). Ten trials comprised 660 total knee arthroplastys and three trials comprised 122 total hip arthroplastys (THAs) met the inclusion criteria. Blood loss was significantly decreased by cryotherapy (MD = -109.68; 95 % CI -210.92 to -8.44; P = 0.03). Cryotherapy did not increase the risk of adverse effect (n.s.). Cryotherapy decreased pain at the second day of postoperative (MD = -1.32; 95 % CI -2.37 to -0.27; P = 0.0003), but did not decreased pain at the first and third day of postoperative (n.s.). Cryotherapy appears effective in these selected patients after joint arthroplasty. The benefits of cryotherapy on blood loss after joint arthroplasty were obvious. However, the subgroup analysis indicated that cryotherapy did not decreased blood loss after THA. Cryotherapy did not increase the risk of adverse effect. Cryotherapy decreased pain at the second day of postoperative, but did not decreased pain at the first and third day of postoperative. II.

  7. Histopathological approach for diagnosis of intravascular leiomyosarcoma of the femoral vein

    Directory of Open Access Journals (Sweden)

    Gaurav Singal

    2016-04-01

    Full Text Available Malignant tumors arising from venous walls in the lower extremities are uncommon and intravascular leiomyosarcoma represents only a small proportion and rare of soft tissue leiomyosarcoma. All publications in the literature are of small clinical series or case reports. We present a case of primary leiomyosarcoma of the femoral vein in a 40 year old man; which is a rare lesion with less than 40 cases reported. The patient presented with swelling and localized leg pain. The diagnosis was made histopathologically, the tumor was resected, vascular reconstruction was performed, and for postoperative radiation therapy and chemotherapy patient was referred to the oncologist. Primary leiomyosarcoma of a major peripheral artery is extremely rare, and this report share the clinical presentation, histopathological findings, treatment, and prognosis in these patients

  8. Femoral Component External Rotation Affects Knee Biomechanics: A Computational Model of Posterior-stabilized TKA.

    Science.gov (United States)

    Kia, Mohammad; Wright, Timothy M; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Sculco, Peter K; Westrich, Geoffrey H; Imhauser, Carl W

    2018-01-01

    The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees? We incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and

  9. Lateral femoral traction pin entry: risk to the femoral artery and other medial neurovascular structures

    Directory of Open Access Journals (Sweden)

    Appleton Paul

    2010-01-01

    Full Text Available Abstract Background Femoral skeletal traction assists in the reduction and transient stabilization of pelvic, acetabular, hip, and femoral fractures when splinting is ineffective. Traditional teaching has recommended a medial entry site for insertion of the traction pin in order to minimize injury to the femoral artery as it passes through Hunter's canal. The present anatomical study evaluates the risk to the femoral artery and other medial neurovascular structures using a lateral entry approach. Methods Six embalmed cadavers (twelve femurs were obtained for dissection. Steinman pins were drilled from lateral to medial at the level of the superior pole of the patella, at 2 cm, and at 4 cm proximal to this point. Medial superficial dissection was then performed to identify the saphenous nerve, the superior medial geniculate artery, the adductor hiatus, the tendinous insertion of the adductor magnus and the femoral artery. Measurements localizing these anatomic structures relative to the pins were obtained. Results The femoral artery was relatively safe and was no closer than 29.6 mm (mean from any of the three Steinman pins. The superior medial geniculate artery was the medial structure at most risk. Conclusions Lateral femoral traction pin entry is a safe procedure with minimal risk to the saphenous nerve and femoral artery. Of the structures examined, only the superior medial geniculate artery is at a risk of iatrogenic injury due to its position. The incidence of such injury in clinical practice and its clinical significance is not known. Lateral insertion facilitates traction pin placement since it minimizes the need to move the contralateral extremity out of the way of the drilling equipment or the need to elevate or externally rotate the injured extremity relative to the contralateral extremity.

  10. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie

    2012-01-01

    Background The results of primary total hip arthroplasties (THAs) after pediatric hip diseases such as developmental dysplasia of the hip (DDH), slipped capital femoral epiphysis (SCFE), or Perthes' disease have been reported to be inferior to the results after primary osteoarthritis of the hip (OA.......9%) were operated due to pediatric hip diseases (3.1% for Denmark, 8.8% for Norway, and 1.9% for Sweden) and 288,435 THAs (77.8%) were operated due to OA. Unadjusted 10-year Kaplan-Meier survival of THAs after pediatric hip diseases (94.7% survival) was inferior to that after OA (96.6% survival......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...

  11. “Table-less” and “Assistant-less” Direct Anterior Approach to Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Daniel C Allison

    2015-10-01

    Full Text Available In recent years, specialized, non-sterile, traction table systems have facilitated Direct Anterior Approach (DAA hip arthroplasty. To combat the potential downsides of these traction systems, a sterile, intra-operative retractor option has emerged as a means to access the surgical site more easily, minimize soft-tissue trauma, and reduce the degree of required human assistance. This chapter describes the setup, surgical approach, and early results of a retractor system (the Phantom MIS Anterior Hip Retractor system [TeDan Surgical Innovations, Inc. {TSI}, Houston, Texas, US Patent # 8,808,176 B2], which uses a standard operating table, allows preparation of both lower extremities free in the surgical field, is compatible with fluoroscopy, and aids in both acetabular and femoral exposure, preparation, and implantation. Early outcome data indicates that this system significantly minimizes the need for surgical assistance, while allowing for safe and effective DAA performance, facilitating the procedure for high-volume surgeons and shortening the learning curve for surgeons new to the procedure.

  12. Nonunion of the femoral neck: Possibilities and limitations of the various treatment modalities

    Directory of Open Access Journals (Sweden)

    Raaymakers Ernst

    2008-01-01

    Full Text Available Nowadays in cases of nonunions of the femoral neck, the surgeon is tempted to perform prosthetic replacement of the hip, more so if there is also evidence of avascular necrosis of the head of femur. This provides rapid pain relief and allows early mobilization. However, long-term results of hip arthroplasties, especially in younger people and in the presence of osteopenia, are not always as expected; and a less radical approach is worth considering. The intertrochanteric valgization osteotomy, described by Pauwels, is an excellent alternative for healthy patients up to 65 years of age with a nonunion of the femoral neck. A union rate of 80-90% of the nonunion is described by most authors. Leg length inequallity, rotational and angular deformities can be corrected at the same time. During the period 1973-1995, we performed valgization osteotomy according to Pauwels in 66 patients of, 18-72 years old (mean 49.5 years. 24 (37% of our patients died 4 months to 24 years (mean: 9.5 years after the operation. Union of the femoral neck was achieved in 58 (88% of the 66 patients; union of the osteotomy in 65 patients (99%. A good or excellent result was achieved in 62% (23 uneventful and 13 with healed, necrosis/arthrosis without need for further treatment of our patients. However, the method has its limits. We feel if there is too little bone stock inside the femoral head, a valgization osteotomy does not give good result. The radiographic signs of avascular necrosis in patients over 30 years of age is considered a contraindication for an osteotomy. However our results show that it is worthwhile trying to save the joint of young patients even in case of a segmental collapse. In the race between revascularization and collapse, often revascularization is the winner. We deliberately give nature its chance and don′t rely on the result of bleeding from drill holes in the head, nuclear scans and other methods to estimate vascularity. A secondary total hip

  13. Shoulder arthroplasty for sequelae of poliomyelitis.

    Science.gov (United States)

    Werthel, Jean-David; Schoch, Bradley; Sperling, John W; Cofield, Robert; Elhassan, Bassem T

    2016-05-01

    Polio infection can often lead to orthopedic complications such as arthritis, osteoporosis, muscle weakness, skeletal deformation, and chronic instability of the joints. The purpose of this study was to assess the outcomes and associated complications of arthroplasty in shoulders with sequelae of poliomyelitis. Seven patients (average age, 70 years) were treated between 1976 and 2013 with shoulder arthroplasty for the sequelae of polio. One patient underwent reverse shoulder arthroplasty, 2 had a hemiarthroplasty, and 4 had total shoulder arthroplasty. Average follow-up was 87 months. Outcome measures included pain, range of motion, and postoperative modified Neer ratings. Overall pain scores improved from 5 to 1.6 points (on a 5-point scale) after shoulder arthroplasty. Six shoulders had no or mild pain at latest follow-up, and 6 shoulders rated the result as much better or better. Mean shoulder elevation improved from 72° to 129°, and external rotation improved from 11° to 56°. Average strength in elevation decreased from 3.9 to 3.4 postoperatively, and external rotation strength decreased from 3.9 to 3.3. This, however, did not reach significance. Evidence of muscle imbalance with radiographic instability was found in 4 shoulders that demonstrated superior subluxation, anterior subluxation, or both. This remained asymptomatic. No shoulder required revision or reoperation. Shoulder arthroplasty provides significant pain relief and improved motion in patients with sequelae of poliomyelitis. Muscle weakness may be responsible for postoperative instability, and careful selection of the patient with good upper extremity muscles must be made. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Varus femoral osteotomy improves sphericity of the femoral head in older children with severe form of Legg-Calvé-Perthes disease.

    Science.gov (United States)

    Terjesen, Terje; Wiig, Ola; Svenningsen, Svein

    2012-09-01

    In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.

  15. Radiological aspects of Arthroplasties

    International Nuclear Information System (INIS)

    Garcia, Sara Eugenia; Barragan, John Henry; Narvaez, Jorge Andres

    2008-01-01

    The development of new surgical techniques, of new prosthetic materials, and the increase in life expectancy with greater coverage of health services has ugmented the performance of hip replacements in our country. The radiologist should be familiar with the different surgical techniques and prosthetic devices, the evaluation of its components and associated complications. The most frequently performed arthroplasties are: shoulder, elbow, hip and knee replacement. This article reviews the most frequent prosthetic devices used, the radiological aspects of arthroplasties and their most common complications.

  16. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  17. Total ankle arthroplasty: An imaging overview

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Da Rae; Choi, Yun Sun; Chun, Ka Young; Jung, Yoon Young; Kim, Jin Su; Young, Ki Won [Eulji Hospital, Eulji University, Seoul (Korea, Republic of); Potter, Hollis G.; Li, Angela E. [Dept. of Radiology and Imaging, Hospital for Special Surgery, New York (United States)

    2016-06-15

    With advances in implant technology, total ankle arthroplasty (TAA) has become an increasingly popular alternative to arthrodesis for the management of end-stage ankle arthritis. However, reports in the literature do not focus on the imaging features of TAA. Through a literature review, we demonstrate basic design features of the current ankle arthroplasty system, and the normal and abnormal postoperative imaging features associated with such devices. Pre- and postoperative evaluations of ankle arthroplasty mainly include radiography; in addition, computed tomography and magnetic resonance imaging provide further characterization of imaging abnormalities. Familiarization with multimodal imaging features of frequent procedural complications at various postoperative intervals is important in radiological practice.

  18. [Case-control study on effect of rivaroxaban on the risk of hidden bleeding after total hip arthroplasty].

    Science.gov (United States)

    Li, Jun; Jing, Jue-Hua; Shi, Zhan-Jun; Zhou, Yun

    2014-01-01

    To investigate the risk of hidden blood loss about applying rivaroxaban after total hip arthroplasty. From October 2009 to May 2012,88 patients with femoral head necrosis were treated with primary total hip arthroplasty. All the patients were divided into Rivaroxaban group(44 cases)and control group(44 cases). There were 25 males and 19 females in the Rivaroxaban group, with an average age of (58.48 +/- 15.19) years old; in the control group,24 patients were male and 20 patients were female, with an average age of (61.11 +/- 13.54) years old. The patients in the Rivaroxaban group took Rivaroxaban orally from the first day after operation with a dose of 10 mg each day, and treatment course was 14 days. The patients in the control group took placebo orally at the same time. Dominant blood loss and transfusion were recorded, blood routine examinations were taken before operation and at 3 days after operation. The total blood loss and hidden blood loss were calculated according to the formula. The mean total blood loss was (1509.56 +/- 325.23) ml and the hidden blood loss was(581.47 +/- 215.01) ml, accounting for (37.88 +/- 10.42)% in the Rivaroxaban group. The mean total blood loss was (1262.30 +/- 397.95) ml and the hidden blood loss was (395.59 +/- 97.33) ml, accounting for (30.62 +/- 0.20)% in the control group. The total blood loss, hidden blood loss and transfusion in the Rivaroxaban group was significantly more than those in control group,b ut there was no significant difference on dominant blood loss between two groups. Rivaroxaban increased the overall bleeding risk of total hip arthroplasty, especially hidden bleeding risk, which should be careful used.

  19. Preoperative Optimization of Total Joint Arthroplasty Surgical Risk: Obesity.

    Science.gov (United States)

    Fournier, Matthew N; Hallock, Justin; Mihalko, William M

    2016-08-01

    Obesity is a problem that is increasing in prevalence in the United States and in other countries, and it is a common comorbidity in patients seeking total joint arthroplasty for degenerative musculoskeletal diseases. Obesity, as well as commonly associated comorbidities such as diabetes mellitus, cardiovascular disease, and those contributing to the diagnosis of metabolic syndrome, have been shown to have detrimental effects on total joint arthroplasty outcomes. Although there are effective surgical and nonsurgical interventions which can result in weight loss in these patients, concomitant benefit on arthroplasty outcomes is not clear. Preoperative optimization of surgical risk in obese total joint arthroplasty patients is an important point of intervention to improve arthroplasty outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. TOTAL HIP ARTHROPLASTY IN CHILDREN WHO HAVE UNDERGONE ARTHROPLASTY WITH DEMINERALIZED BONE-CARTILAGE ALLOCUPS

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  1. Total hip arthroplasty in children who have undergone arthroplasty with demineralized bone-cartilage allocups

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  2. Risk factors for blood transfusion after shoulder arthroplasty.

    Science.gov (United States)

    Padegimas, E M; Clyde, C T; Zmistowski, B M; Restrepo, C; Williams, G R; Namdari, S

    2016-02-01

    Currently, there is little information about the need for peri-operative blood transfusion in patients undergoing shoulder arthroplasty. The purpose of this study was to identify the rate of transfusion and its predisposing factors, and to establish a blood conservation strategy. We identified all patients who had undergone shoulder arthroplasty at our hospital between 1 January 2011 and 31 December 2013. The rate of transfusion was determined from the patient's records. While there were exceptions, patients typically underwent transfusion if they had a level of haemoglobin of transfusion. High- and low-risk cohorts for transfusion were identified from a receiver operating characteristic (ROC) curve. Of 1174 shoulder arthroplasties performed on 1081 patients, 53 cases (4.5%) required transfusion post-operatively. Predictors of blood transfusion were a lower pre-operative haematocrit (p transfusion. In total 48 of the 436 (11%) shoulder arthroplasties with a pre-operative haematocrit transfusion compared with five of the 738 (0.70%) shoulder arthroplasties with a haematocrit above this level. We found that transfusion was needed less frequently than previously described for shoulder arthroplasty. Patients with a pre-operative haematocrit blood transfusion, while those with a haematocrit above this level are unlikely to require transfusion. The rate of transfusion after shoulder arthroplasty is under 5%, and those with a pre-operative haematocrit greater than or equal to 39.6% have a very low likelihood (transfusion. ©2016 The British Editorial Society of Bone & Joint Surgery.

  3. Digital versus analogue preoperative planning of total hip arthroplasties - A randomized clinical trial of 210 total hip arthroplasties

    NARCIS (Netherlands)

    The, Bertram; Verdonschot, Nico; van Horn, Jim R.; van Ooijen, Peter M. A.; Diercks, Ron L.

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized

  4. Mating of a PROSTALAC spacer with an intramedullary nail for reconstruction of an infected interprosthetic femoral shaft fracture: a case report.

    Science.gov (United States)

    Kamath, Atul F; Austin, Daniel; Lee, Gwo-Chin

    2012-08-01

    Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer mated with an intramedullary nail. The acetabulum was then exposed and the necrotic cartilage was removed and curetted. The acetabulum was reamed to accept a PROSTALAC acetabular shell. The shell was cemented into the acetabulum with antibiotic cement. The custom-made spacer was then inserted distally first into the tibia. The distal end of the intramedullary nail was interlocked with a bicortical bolt to minimise nail rotation. Antibiotic-impregnated cement was moulded around the nail and spacer. The proximal end of the spacer was then reduced into the acetabular socket, and the joint was irrigated and the wound closed. A customised abduction brace was fitted, and partial weight bearing was allowed. Sufficient leg length, soft-tissue tension, and range of hip motion were restored, and a total femur and constrained liner was re-implanted 4 months later. Mating of an intramedullary nail with a PROSTALAC spacer is a viable reconstructive option.

  5. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek, E-mail: abhiortho27@gmail.co [Department of Orthopedics, 513, Thermal Colony, Sector-22, Faridabad 121005, Haryana (India); Sankaran, Balu; Varghese, Mathew [Department of Orthopedics, St Stephen' s Hospital, Tis hazari, Delhi, New Delhi 110054 (India)

    2010-09-15

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  6. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    International Nuclear Information System (INIS)

    Kaushik, Abhishek; Sankaran, Balu; Varghese, Mathew

    2010-01-01

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  7. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  8. Femoral revision with impaction allografting and an uncemented femoral component

    DEFF Research Database (Denmark)

    Nickelsen, T N; Erenbjerg, M; Retpen, J B

    2008-01-01

    A technique for uncemented revision of the femoral component which combines impaction allografting and the use of a long-stemmed proximally coated titanium prostheses (Bimetric, Biomet Inc.) is described. The results after a mean follow-up of 112 months are reported. From 1991 to 1995 femoral...... implants 88% had no pain, 10% had slight pain and only 2% had severe pain. Thirty-eight patients had radiographic signs of remodelling of the graft and/or cortical repair. In cases with a successful outcome, the results have been encouraging in relation to clinical performance, regeneration of bone...

  9. the choice of arthroplasty implants in a developing country

    African Journals Online (AJOL)

    The use of arthroplasty in end stage arthritis in Kenya is now established. Arthroplasty is now carried out in a number of the main city hospitals, particularly in the private sector and in some mission hospitals. Some patients travel out of the country, particularly to India in search of arthroplasty. There is, also, an increasing.

  10. CT and MRI of hip arthroplasty

    International Nuclear Information System (INIS)

    Cahir, J.G.; Toms, A.P.; Marshall, T.J.; Wimhurst, J.; Nolan, J.

    2007-01-01

    Plain films are the initial imaging method of choice for evaluation of hip arthroplasty. Recent advances in technology and imaging techniques have largely overcome the problems of beam hardening in computed tomography (CT) and magnetic susceptibility artefact in magnetic resonance imaging (MRI). CT and MRI have now become useful imaging techniques in the assessment of hip arthroplasty

  11. Evaluation of interference fit and bone damage of an uncemented femoral knee implant.

    Science.gov (United States)

    Berahmani, Sanaz; Hendriks, Maartje; de Jong, Joost J A; van den Bergh, Joop P W; Maal, Thomas; Janssen, Dennis; Verdonschot, Nico

    2018-01-01

    During implantation of an uncemented femoral knee implant, press-fit interference fit provides the primary stability. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much press-fit interference fit is eventually achieved. Five cadaveric femora were prepared and implantation was performed by an experienced surgeon. Micro-CT- and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. Additionally, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions. By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. Our analysis showed an average cutting error of 0.67mm (SD 0.17mm), which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48mm (SD 0.27mm), which was close to the nominal value of 1.5mm. We observed combinations of bone damage and elastic deformation in all bone specimens, which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation. The results of the current study indicate different factors that interact while implanting an uncemented femoral knee component. This knowledge can be used to fine-tune design criteria of femoral components to achieve adequate primary stability for all patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  13. Avascular Necrosis Is Associated With Increased Transfusions and Readmission Following Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Lovecchio, Francis C; Manalo, John Paul; Demzik, Alysen; Sahota, Shawn; Beal, Matthew; Manning, David

    2017-05-01

    Avascular necrosis (AVN) may confer an increased risk of complications and readmission following total hip arthroplasty (THA). However, current risk-adjustment models do not account for AVN. A total of 1706 patients who underwent THA for AVN from 2011 to 2013 were selected from the American College of Surgeon's National Surgical Quality Improvement Program database and matched 1:1 to controls using a predetermined propensity score algorithm. Rates of 30-day medical and surgical complications, readmissions, and reoperations were compared between cohorts. Propensity-score logistic regression was used to determine independent associations between AVN and outcomes of interest. Patients with AVN had a higher rate of medical complications than those without AVN (20.3% vs 15.3%, respectively; PAvascular necrosis of the femoral head is an independent risk factor for transfusion up to 72 hours postoperatively and readmission up to 30 days following total hip replacement. [Orthopedics. 2017; 40(3):171-176.]. Copyright 2017, SLACK Incorporated.

  14. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  15. A Morphological Insight of the Femoral Vein

    Directory of Open Access Journals (Sweden)

    Ferreira AH

    2015-10-01

    Full Text Available A total of 13 cadavers (12 men and 1 women of different age group were used for the study with the purpose to determine the prevalence of femoral vein duplication. Lower limb regions (26 sides were carefully dissected as per the standard dissection procedure. Femoral vein (unitruncular was found in 96.15% of specimen. Bitruncular configurations (total bifidity was found in a male cadaver of 75 years of age (3.85%. In the right lower limb, 6.5 cms below the inguinal ligament the femoral vein - lateral ramus received the lateral circumflex femoral vein, and the medial circumflex femoral vein, and the lateral and medial ramii formed a common venous trunk. Knowledge of the truncular venous variations is important to recognize and avoid potential errors in diagnosis of deep venous thrombosis of the femoral vein, in the case of an occluded duplicated trunk.

  16. Extensive Bone Reaction From Catastrophic Oxidized Zirconium Wear.

    Science.gov (United States)

    Cassar-Gheiti, Adrian J; Collins, Dennis; McCarthy, Tom

    2016-01-01

    The use of alternative bearing surfaces for total hip arthroplasty has become popular to minimize wear and increase longevity, especially in young patients. Oxidized zirconium (Oxinium; Smith & Nephew, Memphis, Tennessee) femoral heads were introduced in the past decade for use in total hip arthroplasty. The advantages of oxidized zirconium include less risk of fracture compared with traditional ceramic heads. This case report describes a patient with a history of bilateral avascular necrosis of the femoral head after chemotherapy for acute lymphoblastic leukemia. Nonoperative management of avascular necrosis failed, and the patient was treated with bilateral total hip arthroplasty. The patient was followed at regular intervals and had slow eccentric polyethylene wear during a 10-year period. After 10 years, the patient had accelerated wear, with femoral and acetabular bone changes as a result of Oxinium and ultrahigh-molecular-weight polyethylene wear during a 6-month period. This article highlights the unusual accelerated bone changes that occurred as a result of Oxinium wear particles. Copyright 2016, SLACK Incorporated.

  17. Is the lateral radiograph necessary for the management of intra-capsular proximal femoral fractures?

    International Nuclear Information System (INIS)

    Korim, Muhammad Tawfiq; Mohan Reddy, Venthurla Ram; Gibbs, David; Wildin, Clare

    2012-01-01

    Aims: To investigate if a lateral hip radiograph is always needed in the management of intra-capsular proximal femoral fractures. Furthermore, we sought to evaluate if a radiographer could accurately identify cases in which the lateral radiograph is not required. Methods: All patients who underwent surgical management of an intra-capsular proximal femoral fracture over a 3 month period at our unit were identified. Radiographs were reviewed by 6 observers: 2 consultant orthopaedic surgeons, 2 registrars, and 2 radiographers. Initially the observers viewed the AP radiographs alone and classified the fractures into displaced, undisplaced, or unclear categories. They were then shown the lateral view and asked for a diagnosis and management plan. Comparison of diagnosis and management based on AP views alone, and AP in-combination with a lateral view was made. Results: 90 patients were included; the mean age was 80.8 years with a range of 42–100 years. 73 underwent arthroplasty and 17 had internal fixation. All observers, including the radiographer were able to make a surgical decision in 90% of the cases based on AP views alone. Lateral radiographs improved the diagnostic accuracy by 6%. The availability of the lateral view did not alter the management in patients where the AP clearly demonstrated a displaced fracture. Conclusion: Elderly patients with a displaced intra-capsular fracture identifiable on the AP do not require a lateral radiograph. Such patients can be accurately identified by the radiographer. Patient discomfort experienced during positioning for the lateral view would be avoided, and a financial saving made.

  18. TOTAL HIP ARTHROPLASTY IN OSTEOPETROSIS – REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    Zmago Krajnc

    2004-04-01

    Full Text Available Background. Authors introduced a case of a 27-year men with osteopetrosis with hip arthrosis. He has an autosomal – dominant form of disease and he needed total hip arthroplasty. There are seven cases described in literature with developed hip arthrosis by osteopetrosis.Methods. TEP implantation represents the greates surgical challenge in this patients, especially creation of intramedullary canal in femur and implantation of the femoral stem because of the very dense and brittle bones. This article describes the operative technique used in the case involved. It proved to be a very good solution.Results. The patient was released from the hospital ten days after implantation of total hip endoprosthesis. Three months after the operation the patient started to walk without aid of canes, he had non pain, and his range of motion was almost normal.Conclusions. Severe coxarthrosis is a rare complication of osteopetrosis. Great care must be taken with implantation of total hip endoprosthesis, especially with preparation of medular canal. It was recommended hand drilling under x-rays to exercise maximal control because reaming can cause false root of stem and greater probability of fracture.

  19. Congenital cheek teratoma with temporo-mandibular joint ankylosis managed with ultra-thin silicone sheet interpositional arthroplasty.

    Science.gov (United States)

    Bhatnagar, Ankur; Verma, Vinay Kumar; Purohit, Vishal

    2013-01-01

    Primary cheek teratomas are rare with joint ankylosis (TMJA). The fundamental aim in the treatment of TMJA is the successful surgical resection of ankylotic bone, prevention of recurrence, and aesthetic improvement by ensuring functional occlusion. Early treatment is necessary to promote proper growth and function of mandible and to facilitate the positive psychological development of child. Inter-positional arthroplasty with ultra-thin silicone sheet was performed. Advantages include short operative time, less foreign material in the joint space leading to negligible foreign body reactions and least chances of implant extrusion. Instead of excising a large bony segment, a thin silicone sheet was interposed and then sutured ensuring preservation of mandibular height. Aggressive post-operative physiotherapy with custom made dynamic jaw exerciser was used to prevent recurrence.

  20. Pelvic X-ray examinations in follow-up of hip arthroplasty or femoral osteosynthesis – Dose reduction and quality criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten, E-mail: jost.kloth@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Rickert, Markus, E-mail: markus.rickert@ortho.med.uni-giessen.de [Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Klinikstrasse 33, D-35392 Giessen (Germany); Gotterbarm, Tobias, E-mail: tobias.gotterbarm@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Stiller, Wolfram, E-mail: wolfram.stiller@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Burkholder, Iris, E-mail: stabil@burkholder.de [Department of Nursing and Health, University of Applied Sciences of the Saarland, Goebenstrasse 40, D-66117 Saarbruecken (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Ewerbeck, Volker, E-mail: volker.ewerbeck@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Weber, Marc-André, E-mail: marcandre.weber@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany)

    2015-05-15

    Highlights: • Pelvic radiographs with speed class 400 and 800 in follow-up of hip arthroplasty were compared. • Radiographs with reduced dose (800) were not inferior to those with standard dose (400). • We recommend speed class 800 as new reference parameter in these examinations. - Abstract: Objective: Digital plain radiographs of the pelvis are frequently performed in follow-up examinations of patients who received total hip arthroplasty (THA) or osteosynthesis (OS). Thus, the purpose was to reduce the radiation dose and to determine objective quality control criteria to ensure accurate assessment. Materials and methods: Institutional review board approval was obtained. In this prospective randomized study, 289 patients underwent X-ray examination of the pelvis as follow up after receiving THA or OS with standard and reduced dose. The evaluation of the plain radiographs was conducted using the following criteria: bone–implant interface, implant–implant discrimination, implant–surface character and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more or more than 2 criteria with 2 points, the radiograph was scored as “not assessable“. The study was designed as non-inferiority-trial. Results: Seven (2.4%) examined X-rays were scored as not assessable. There was no statistical inferiority between the examinations with standard (0.365 mSv) or reduced dose (0.211 mSv). Reduced dose only led to limitations in the evaluation of ceramic components with low clinical impact in most scenarios. Conclusion: Plain radiography of the pelvis in patients with THA or OS can be performed with a dose reduction of about 42% without a loss of important information. The obtained quality control criteria were clinically applicable.

  1. Biological Reconstruction Following the Resection of Malignant Bone Tumors of the Pelvis

    Directory of Open Access Journals (Sweden)

    Frank Traub

    2013-01-01

    Full Text Available Background. Surgical treatment of malignant pelvic bone tumors can be very challenging. The objective of this retrospective study was to evaluate the oncological as well as the clinical and functional outcome after limb salvage surgery and biological reconstruction. Methods. The files of 27 patients with malignant pelvic bone tumors, who underwent surgical resection at our department between 2000 and 2011, were retrospectively analyzed (9 Ewing's sarcoma, 8 chondrosarcoma, 4 osteosarcoma, 1 synovial sarcoma, 1 malignant fibrous histiocytoma, and 4 carcinoma metastases. Results. After internal hemipelvectomy reconstruction was performed by hip transposition (, using autologous nonvascularised fibular graft ( or autologous iliac crest bone graft (. In one patient a proximal femor prothetis and in three patients a total hip prosthesis was implanted at the time of resection. The median follow-up was 33 months. Two- and five-year disease-specific survival rates of all patients were 86.1% and 57.7%, respectively. The mean functional MSTS score was 16.5 (~55% for all patients. Conclusion. On the basis of the oncological as well as the clinical and functional outcome, biological reconstruction after internal hemipelvectomy seems to be a reliable technique for treating patients with a malignant pelvic bone tumor.

  2. [Repeat hepatic resections].

    Science.gov (United States)

    Popescu, I; Ciurea, S; Braşoveanu, V; Pietrăreanu, D; Tulbure, D; Georgescu, S; Stănescu, D; Herlea, V

    1998-01-01

    Five cases of iterative liver resections are presented, out of a total of 150 hepatectomies performed between 1.01.1995-1.01.1998. The resections were carried out for recurrent adenoma (one case), cholangiocarcinoma (two cases), hepatocellular carcinoma (one case), colo-rectal cancer metastasis (one case). Only cases with at least one major hepatic resection were included. Re-resections were more difficult than the primary resection due, first of all, to the modified vascular anatomy. Intraoperative ultrasound permitted localization of intrahepatic recurrences. Iterative liver resection appears to be the best therapeutical choice for patients with recurrent liver tumors.

  3. Imaging patellar complications after knee arthroplasty

    International Nuclear Information System (INIS)

    Melloni, Pietro; Valls, Rafael; Veintemillas, Maite

    2008-01-01

    The purpose of this study is to describe complications affecting the patella in patients with total or partial knee arthroplasty. We respectively analysed plain-film radiographs, as well as ultrasound images when acquired, in a consecutive series of 1272 patients. The mean interval from knee replacement to patellar complications was 5 years and 7 months (range, 5 months to 14 years). The complications described include fracture, instability, dislocation or luxation, necrosis of the patella, infection of the patella, erosion of the patella, patellar impingement on the prosthesis and patellar or quadricipital tendon tear. We discuss the pathological imaging findings in the patella and their differential diagnosis after knee arthroplasty. Patellar complications after knee arthroplasty are uncommon but often potentially serious

  4. Imaging patellar complications after knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Melloni, Pietro [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)], E-mail: pmelloni@cspt.es; Valls, Rafael; Veintemillas, Maite [Unitat de Imatge d' Alta Tecnologia, Centre Diagnostic, Corporacio Parc Tauli, Universitat Autonoma de Barcelona, Sabadell (Barcelona) (Spain)

    2008-03-15

    The purpose of this study is to describe complications affecting the patella in patients with total or partial knee arthroplasty. We respectively analysed plain-film radiographs, as well as ultrasound images when acquired, in a consecutive series of 1272 patients. The mean interval from knee replacement to patellar complications was 5 years and 7 months (range, 5 months to 14 years). The complications described include fracture, instability, dislocation or luxation, necrosis of the patella, infection of the patella, erosion of the patella, patellar impingement on the prosthesis and patellar or quadricipital tendon tear. We discuss the pathological imaging findings in the patella and their differential diagnosis after knee arthroplasty. Patellar complications after knee arthroplasty are uncommon but often potentially serious.

  5. Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture

    OpenAIRE

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-01-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nai...

  6. Eradication of multidrug-resistant Acinetobacter baumannii in a female patient with total hip arthroplasty, with debridement and retention: a case report

    Directory of Open Access Journals (Sweden)

    Beieler Alison M

    2009-02-01

    Full Text Available Abstract Introduction Multidrug-resistant Acinetobacter baumannii has become a significant cause of healthcare-associated infections, but few reports have addressed Acinetobacter baumannii infections associated with orthopedic devices. The current recommended treatment for complicated infections due to orthopedic devices, including resistant gram-negative rods, consists of antimicrobial therapy with debridement and removal of implants. Case presentation The patient, a 47-year-old woman, had previously had a prior total hip arthroplasty at 16 years of age for a complex femoral neck fracture, and multiple subsequent revisions. This time, she underwent a fifth revision secondary to pain. Surgery was complicated by hypotension resulting in transfer to the intensive care unit and prolonged respiratory failure. She received peri-operative cefazolin but postoperatively developed surgical wound drainage requiring debridement of a hematoma. Cultures of this grew ampicillin-sensitive Enterococcus and Acinetobacter baumannii (sensitive only to amikacin and imipenem. The patient was started on imipenem. Removal of the total hip arthroplasty was not recommended because of the recent surgical complications, and the patient was eventually discharged home. She was seen weekly for laboratory tests and examinations and, after 4 months of therapy, the imipenem was discontinued. She did well clinically for 7 months before recurrent pain led to removal of the total hip arthroplasty. Intra-operative cultures grew ampicillin-sensitive Enterococcus and coagulase-negative Staphylococcus but no multidrug-resistant Acinetobacter baumannii. The patient received ampicillin for 8 weeks and had not had recurrent infection at the time of writing, 37 months after discontinuing imipenem. Conclusion We describe the successful treatment of an acute infection from multidrug-resistant Acinetobacter baumannii with debridement and retention of the total hip arthroplasty, using

  7. [Laparoscopic liver resection: lessons learned after 132 resections].

    Science.gov (United States)

    Robles Campos, Ricardo; Marín Hernández, Caridad; Lopez-Conesa, Asunción; Olivares Ripoll, Vicente; Paredes Quiles, Miriam; Parrilla Paricio, Pascual

    2013-10-01

    After 20 years of experience in laparoscopic liver surgery there is still no clear definition of the best approach (totally laparoscopic [TLS] or hand-assisted [HAS]), the indications for surgery, position, instrumentation, immediate and long-term postoperative results, etc. To report our experience in laparoscopic liver resections (LLRs). Over a period of 10 years we performed 132 LLRs in 129 patients: 112 malignant tumours (90 hepatic metastases; 22 primary malignant tumours) and 20 benign lesions (18 benign tumours; 2 hydatid cysts). Twenty-eight cases received TLS and 104 had HAS. 6 right hepatectomies (2 as the second stage of a two-stage liver resection); 6 left hepatectomies; 9 resections of 3 segments; 42 resections of 2 segments; 64 resections of one segment; and 5 cases of local resections. There was no perioperative mortality, and morbidity was 3%. With TLS the resection was completed in 23/28 cases, whereas with HAS it was completed in all 104 cases. Transfusion: 4,5%; operating time: 150min; and mean length of stay: 3,5 days. The 1-, 3- and 5-year survival rates for the primary malignant tumours were 100, 86 and 62%, and for colorectal metastases 92, 82 and 52%, respectively. LLR via both TLS and HAS in selected cases are similar to the results of open surgery (similar 5-year morbidity, mortality and survival rates) but with the advantages of minimally invasive surgery. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  8. Current Role of Computer Navigation in Total Knee Arthroplasty.

    Science.gov (United States)

    Jones, Christopher W; Jerabek, Seth A

    2018-01-31

    Computer-assisted surgical (CAS) navigation has been developed with the aim of improving the accuracy and precision of total knee arthroplasty (TKA) component positioning and therefore overall limb alignment. The historical goal of knee arthroplasty has been to restore the mechanical alignment of the lower limb by aligning the femoral and tibial components perpendicular to the mechanical axis of the femur and tibia. Despite over 4 decades of TKA component development and nearly 2 decades of interest in CAS, the fundamental question remains; does the alignment goal and/or the method of achieving that goal affect the outcome of the TKA in terms of patient-reported outcome measures and/or overall survivorship? The quest for reliable and reproducible achievement of the intraoperative alignment goal has been the primary motivator for the introduction, development, and refinement of CAS navigation. Numerous proprietary systems now exist, and rapid technological advancements in computer processing power are stimulating further development of robotic surgical systems. Three categories of CAS can be defined: image-based large-console navigation; imageless large-console navigation, and more recently, accelerometer-based handheld navigation systems have been developed. A review of the current literature demonstrates that there are enough well-designed studies to conclude that both large-console CAS and handheld navigation systems improve the accuracy and precision of component alignment in TKA. However, missing from the evidence base, other than the subgroup analysis provided by the Australian Orthopaedic Association National Joint Replacement Registry, are any conclusive demonstrations of a clinical superiority in terms of improved patient-reported outcome measures and/or decreased cumulative revision rates in the long term. Few authors would argue that accuracy of alignment is a goal to ignore; therefore, in the absence of clinical evidence, many of the arguments against

  9. Femoral shaft fractures

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C. II

    1985-01-01

    The femur is the longest, largest, and strongest bone in the body. Because of its length, width, and role as primary weight-bearing bone, it must tolerate the extremes of axial loading and angulatory stresses. Massive musculature envelopes the femur. This masculature provides abundant blood supply to the bone, which also allows great potential for healing. Thus, the most significant problem relating to femoral shaft fractures is not healing, but restoration of bone length and alignment so that the femoral shaft will tolerate the functional stresses demanded of it

  10. Confirming Sterility of an Autoclaved Infected Femoral Component for Use in an Articulated Antibiotic Knee Spacer: A Pilot Study.

    Science.gov (United States)

    Lyons, Steven T; Wright, Coy A; Krute, Christina N; Rivera, Frances E; Carroll, Ronan K; Shaw, Lindsey N

    2016-01-01

    Antibiotic spacer designs have proven effective at eradicating infection during a two-stage revision arthroplasty. Temporary reuse of the steam-sterilized femoral component and a new all poly tibia component has been described as an effective articulating antibiotic spacer, but sterility concerns persist. Six explanted cobalt chrome femurs from patients with grossly infected TKA's and six stock femurs inoculated with different bacterial species were confirmed to be bacteria-free after autoclaving under a standard gravity-displacement cycle. The effect of steam sterilization on cobalt chrome fragments contaminated with MRSA biofilm was analyzed microscopically to quantify remaining biofilm. The autoclave significantly reduced the biofilm burden on the cobalt chrome fragments. This study confirmed sterility of the femur after a standard gravity-displacement cycle (132°C, 27 PSIG, 10 minutes). Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Management of osteonecrosis of the femoral head in children with sickle cell disease: results of conservative and operative treatments at skeletal maturity.

    Science.gov (United States)

    Mallet, C; Abitan, A; Vidal, C; Holvoet, L; Mazda, K; Simon, A-L; Ilharreborde, B

    2018-02-01

    Sickle cell disease (SCD) is the most common cause of femoral head osteonecrosis (ONFH) during childhood with an overall prevalence of 10%. In children, spontaneous revascularization can occur, as in Legg-Calve-Perthes disease. Consequently, the aim of treatment is to restore proper hip containment to prevent joint arthritis. This is the first study reporting long-term results at skeletal maturity of non-operative and surgical treatments for ONFH in SCD children. All children with ONFH due to SCD were retrospectively reviewed. At initial evaluation, extension of osteonecrosis was radiographically defined using Catterall, lateral pillar Herring and Ficat classifications. Subluxation of the femoral head with Reimers migration index > 30% required surgical treatment including femoral varus osteotomy and/or pelvic osteotomies. Conservative treatment including non-weight bearing and physiotherapy was performed in the remaining cases. Outcomes were assessed at skeletal maturity using the Harris Hip Score (HHS) and the Stulberg classification. Total hip arthroplasty and Stulberg 5 were defined as failures. A total of 25 hips in 17 patients were included (mean follow-up 7.5 years SD 3.4). Mean age at diagnosis was 11.4 years SD 2.9. In all, 15 hips (60%) were classified Catterall 3 and 4 and Herring B and C. A total of 13 patients (52%) underwent surgical treatment. At skeletal maturity, mean HHS was good (81 SD 17), 12 hips (48%) were classified Stulberg 1 and 2, seven hips (28%) were classified Stulberg 3 and 4. Both treatments led to good functional results with 75% of congruent hips at skeletal maturity. IV.

  12. Femoral condyle insufficiency fractures: associated clinical and morphological findings and impact on outcome

    Energy Technology Data Exchange (ETDEWEB)

    Plett, Sara K.; Hackney, Lauren A.; Heilmeier, Ursula; Nardo, Lorenzo; Zhang, Chiyuan A.; Link, Thomas M. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA (United States); Yu, Aihong [Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA (United States); 4th Medical College of Peking University, Department of Radiology, Beijing Jishuitan Hospital, Beijing (China)

    2015-12-15

    To determine the characteristics of femoral condyle insufficiency fracture (FCIF) lesions and their relative associations with the risk of clinical progression. This HIPAA-compliant retrospective study was approved by our Institutional Review Board. Seventy-three patients (age range, 19-95) were included after excluding patients with post-traumatic fractures, bone marrow infarct, osteochondritis dissecans, or underlying tumor. Two board-certified musculoskeletal radiologists classified morphologic findings including lesion diameter, associated bone marrow edema pattern, and associated cartilage/meniscus damage. Electronic medical charts were evaluated for symptoms, risk factors, and longitudinal outcomes, including total knee arthroplasty (TKA). Imaging characteristics were correlated with clinical findings, and comparison of outcome groups was performed using a regression model adjusted for age. The majority of patients with FCIF were women (64.4 %, 47/73), on average 10 years older than men (66.28 ± 15.86 years vs. 56.54 ± 10.39 years, p = 0.005). The most common location for FCIF was the central weight-bearing surface of the medial femoral condyle; overlying full thickness cartilage loss (75.7 %, 53/70) and ipsilateral meniscal injury (94.1 %, 64/68) were frequently associated. Clinical outcomes were variable, with 23.9 % (11/46) requiring TKA. Cartilage WORMS score, adjacent cartilage loss, and contralateral meniscal injury, in addition to decreased knee range of motion at presentation, were significantly associated with progression to TKA (p < 0.05). FCIF are frequently associated with overlying cartilage loss and ipsilateral meniscal injury. The extent of cartilage loss and meniscal damage, in addition to loss of knee range of motion at the time of presentation, are significantly associated with clinical progression. (orig.)

  13. Advances in Proximal Interphalangeal Joint Arthroplasty: Biomechanics and Biomaterials.

    Science.gov (United States)

    Zhu, Andy F; Rahgozar, Paymon; Chung, Kevin C

    2018-05-01

    Proximal interphalangeal (PIP) joint arthritis is a debilitating condition. The complexity of the joint makes management particularly challenging. Treatment of PIP arthritis requires an understanding of the biomechanics of the joint. PIP joint arthroplasty is one treatment option that has evolved over time. Advances in biomaterials have improved and expanded arthroplasty design. This article reviews biomechanics and arthroplasty design of the PIP joint. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Physical activity of elderly patients after total hip arthroplasty.

    Science.gov (United States)

    Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna

    2007-01-01

    Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.

  15. Traumatic Migration of the Bryan Cervical Disc Arthroplasty.

    Science.gov (United States)

    Wagner, Scott C; Kang, Daniel G; Helgeson, Melvin D

    2016-02-01

    Study Design Case study. Objective To describe a case of dislodgment and migration of the Bryan Cervical Disc (Medtronic Sofamor Danek, Memphis, Tennessee, United States) arthroplasty more than 6 months after implantation secondary to low-energy trauma. Methods The inpatient, outpatient, and radiographic medical records of a patient with traumatic migration of the Bryan Cervical Disc arthroplasty were reviewed. The authors have no relevant disclosures to report. Results A 36-year-old man with chronic left upper extremity radiculopathy underwent uncomplicated Bryan Cervical Disc arthroplasty at C5-C6, with complete resolution of his symptoms. Approximately 6 months after his index procedure, he sustained low-energy trauma to the posterior cervical spine, after being struck by a book falling from a shelf. The injury forced his neck into flexion, and though he did not have recurrence of his radiculopathy symptoms, radiographs demonstrated anterior migration of the arthroplasty device. He underwent revision to anterior cervical diskectomy and fusion. Conclusions Although extremely rare, it is imperative that surgeons consider the potential for failure of osseous integration in patients undergoing cervical disk arthroplasty, even beyond 3 to 6 months postoperatively. This concern is especially relevant to press-fit or milled devices like the Bryan Cervical Disc arthroplasty, which lack direct fixation into adjacent vertebral bodies. We are considering modification of our postoperative protocol to improve protection of the device after implantation, even beyond 3 months postoperatively.

  16. Total knee arthroplasty in patients with a previous patellectomy.

    Science.gov (United States)

    Maslow, Jed; Zuckerman, Joseph D; Immerman, Igor

    2013-01-01

    Post-patellectomy patients represent a specific subgroup of patients that may develop arthritis and persistent knee pain and potentially require treatment with total knee arthroplasty. This article reviews the treatment and functional outcomes following total knee arthroplasty in patients with prior patellectomy. A case report is presented as an example of the clinical management of a post-patellectomy patient with significant knee pain and disability treated with total knee arthroplasty. Emphasis will be placed in decision- making, specifically with the use of a posterior stabilized implant. In addition, postoperative strengthening of the quadriceps is essential to compensate for the lack of the patella and increase the success of total knee arthroplasty in this subgroup of patients.

  17. Two-staged Bilateral, Femoral Alignment Osteotomy with Concomitant Total Knee Arthroplasty in an Achondroplasia Patient - A Case Report

    Science.gov (United States)

    Walter, Sebastian G; Schwering, Tobias; Preiss, Stefan

    2017-01-01

    Introduction: Achondroplasia is the most common form of dwarfism in humans and is orthopedically characterized by shortened extremities and an exaggerated lumbar lordosis. The surgical challenges are maintenance of axial alignment during limb lengthening as well as joint preservation and alignment restoration. Case Report: We present a 46-year-old female suffering from achondroplasia with severe pain in both knees. Severe varus deformities of both femurs and degeneration of both knee joints became apparent on clinical and radiological examination. On each femur, we performed one-staged, lateral closed-wedge osteotomy, and total knee arthroplasty (TKA). Subsequently, the patient was relieved of knee joint pain and gained a greater range of motion. Conclusion: One-staged valgization osteotomy and concomitant TKA represents a challenging, yet reasonable, surgical solution in axially severe malaligned and joint degenerated patients. PMID:28819598

  18. Can an arthroplasty risk score predict bundled care events after total joint arthroplasty?

    Directory of Open Access Journals (Sweden)

    Blair S. Ashley, MD

    2018-03-01

    Full Text Available Background: The validated Arthroplasty Risk Score (ARS predicts the need for postoperative triage to an intensive care setting. We hypothesized that the ARS may also predict hospital length of stay (LOS, discharge disposition, and episode-of-care cost (EOCC. Methods: We retrospectively reviewed a series of 704 patients undergoing primary total hip and knee arthroplasty over 17 months. Patient characteristics, 90-day EOCC, LOS, and readmission rates were compared before and after ARS implementation. Results: ARS implementation was associated with fewer patients going to a skilled nursing or rehabilitation facility after discharge (63% vs 74%, P = .002. There was no difference in LOS, EOCC, readmission rates, or complications. While the adoption of the ARS did not change the mean EOCC, ARS >3 was predictive of high EOCC outlier (odds ratio 2.65, 95% confidence interval 1.40-5.01, P = .003. Increased ARS correlated with increased EOCC (P = .003. Conclusions: Implementation of the ARS was associated with increased disposition to home. It was predictive of high EOCC and should be considered in risk adjustment variables in alternative payment models. Keywords: Bundled payments, Risk stratification, Arthroplasty

  19. Oxidised zirconium versus cobalt alloy bearing surfaces in total knee arthroplasty: 3D laser scanning of retrieved polyethylene inserts.

    Science.gov (United States)

    Anderson, F L; Koch, C N; Elpers, M E; Wright, T M; Haas, S B; Heyse, T J

    2017-06-01

    We sought to establish whether an oxidised zirconium (OxZr) femoral component causes less loss of polyethylene volume than a cobalt alloy (CoCr) femoral component in total knee arthroplasty. A total of 20 retrieved tibial inserts that had articulated with OxZr components were matched with 20 inserts from CoCr articulations for patient age, body mass index, length of implantation, and revision diagnosis. Changes in dimensions of the articular surfaces were compared with those of pristine inserts using laser scanning. The differences in volume between the retrieved and pristine surfaces of the two groups were calculated and compared. The loss of polyethylene volume was 122 mm 3 (standard deviation (sd) 87) in the OxZr group and 170 mm 3 (sd 96) in the CoCr group (p = 0.033). The volume loss in the OxZr group was also lower in the medial (72 mm 3 (sd 67) versus 92 mm 3 (sd 60); p = 0.096) and lateral (49 mm 3 (sd 36) versus 79 mm 3 (sd 61); p = 0.096) compartments separately, but these differences were not significant. Our results corroborate earlier findings from in vitro testing and visual retrieval analysis which suggest that polyethylene volume loss is lower with OxZr femoral components. Since both OxZr and CoCr are hard surfaces that would be expected to create comparable amounts of polyethylene creep, the differences in volume loss may reflect differences in the in vivo wear of these inserts. Cite this article: Bone Joint J 2017;99-B:793-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  20. Case report: AVN of the femoral head five year follow-up of the combination of ipsilateral femoral neck and sub-trochanteric fracture.

    Science.gov (United States)

    Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng

    2016-04-01

    To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.

  1. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  2. Slipped capital femoral epiphysis: A modern treatment protocol

    Directory of Open Access Journals (Sweden)

    Slavković Nemanja

    2009-01-01

    Full Text Available The treatment of a patient with slipped capital femoral epiphysis begins with an early diagnosis and accurate classification. On the basis of symptom duration, clinical findings and radiographs, slipped capital femoral epiphysis is classified as pre-slip, acute, acute-on-chronic and chronic. The long-term outcome of slipped capital femoral epiphysis is directly related to severity and the presence or absence of avascular necrosis and/or chondrolysis. Therefore, the first priority in the treatment of slipped capital femoral epiphysis is to avoid complications while securing the epiphysis from further slippage. Medical treatment of patients with acute and acute-on-chronic slipped capital femoral epiphysis, as well as those presented in pre-slip stage, is the safest, although time-consuming. Manipulations, especially forced and repeated, are not recommended due to higher avascular necrosis risk. The use of intraoperative fluoroscopy to assist in the placement of internal fixation devices has markedly increased the success of surgical treatment. Controversy remains as to whether the proximal femoral epiphysis in severe, chronic slipped capital femoral epiphysis should be realigned by extracapsular osteotomies or just fixed in situ. The management protocol for slipped capital femoral epiphysis depends on the experience of the surgeon, motivation of the patient and technical facilities.

  3. Fast-track revision knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Otte, Niels Kristian Stahl; Kristensen, Billy B

    2011-01-01

    Abstract Background and purpose Fast-track surgery has reduced the length of hospital stay (LOS), morbidity, and convalescence in primary hip and knee arthroplasty (TKA). We assessed whether patients undergoing revision TKA for non-septic indications might also benefit from fast-track surgery....... Methods 29 patients were operated with 30 revision arthroplasties. Median age was 67 (34-84) years. All patients followed a standardized fast-track set-up designed for primary TKA. We determined the outcome regarding LOS, morbidity, mortality, and satisfaction. Results Median LOS was 2 (1-4) days...

  4. A STUDY ON FEMORAL ANTEVERSION IN ADULT DRY FEMORA OF SOUTH INDIAN POPULATION

    Directory of Open Access Journals (Sweden)

    Sushma Korukonda

    2017-01-01

    Full Text Available BACKGROUND Femoral Neck Anteversion (FNA is an important parameter for diagnosis of gait abnormality in children, risk of various congenital and acquired orthopaedic disorders as well as corrective osteotomy and hip arthroplasty. Femoral anteversion is the lateral rotation of the neck of the femur to the long axis of its shaft. Variability in FNA has been reported and is due to torsional forces applied on femur during development. The aim of this study was to estimate the angle of anteversion of femur in both genders on both sides. The present study was an attempt to provide baseline data of FNA in South Indian population, in particular, Andhra Pradesh. MATERIALS AND METHODS The study was conducted mechanically on 70 dried adult unpaired human femora, i.e. 48 male and 22 female bones. The Kingsley Olmsted 1 method was used for the study and the data was analysed. Statistical analysis - Statistical analysis was done using student unpaired ‘t’ test. The data was analysed using GraphPad Prism 5.0 (Free Trial Version. RESULTS Out of the 70 femora undertaken, mean value of FNA obtained in male is 15.95, 14.1 on right and 17.8 on left sides and in female it is 19.2, 21.8 on right and 16.6 on left side. Statistical analysis revealed significant (p < 0.05 greater average anteversion in female bones and right-left variations being greater on the left side. CONCLUSION In the present study, the mean FNA was 17.8 deg. There was a gender variation for the FNA values in the population studied with females showing higher value than the male with a statistically significant difference. The reason for the difference obtained could be the small sample size of female femora due to the rarity of the donated female bodies. The value was higher on the left side than the right; 50% of the femora had the range of 16 - 25 deg of FNA. The overall mean of femoral anteversion determined is very much different from the studies in various regions in India.

  5. Frequency of ipsilateral femoral neck fractures in patients with ...

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft fractures. Objective: To establish the frequency of ipsilateral femoral neck fractures amongst all patients presenting with femoral shaft fractures in Mulago Hospital. Methodology: This was a descriptive ...

  6. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  7. Patient-reported outcome after fast-track knee arthroplasty

    DEFF Research Database (Denmark)

    Larsen, Kristian; Hansen, Torben B; Søballe, Kjeld

    2012-01-01

    PURPOSE: The purpose of this study was to describe patient-related functional outcomes after fast-track total knee arthroplasty and unicompartmental knee arthroplasty. Furthermore, we wanted to assess physical areas where an additional need for rehabilitation could be identified, and finally, we...

  8. Hip resurfacing arthroplasty: current status and future perspectives

    Directory of Open Access Journals (Sweden)

    K Corten

    2011-03-01

    Full Text Available Hip resurfacing arthroplasty (HRA is a concept of hip replacement that allows treating young active patients with a femoral bone preserving procedure. The proposed advantages of resuming an active lifestyle with increased frequency and duration of sports activities have been shown to be realistic. The 30-year cost-effectiveness in young male patients has been shown to be higher in resurfacing compared to conventional total hip replacement (THA. However, prognosticators of an inferior outcome have also been identified. The most important patient related factors are secondary osteoarthritis as the indication for surgery such as post-childhood hip disorders or AVN, female gender, smaller component sizes and older age (>65 years for males and >55 years for females. In addition, surgical technique (approach and cementing technique and component design are also important determinant factors for the risk of failure. Moreover, concerns have surfaced with respect to high metal ion concentrations and metal ion hypersensitivities. In addition, the presumed ease of revising HRA has not reflected in improved or equal survivorship in comparison to a primary THA. This highlights the importance of identifying patient-, surgery-, and implant-related prognosticators for success or failure of HRA. Rather than vilifying the concept of hip resurfacing, detailed in depth analysis should be used to specify indications and improve implant design and surgical techniques.

  9. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    Science.gov (United States)

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was 125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA 125 degrees and caution is advocated when using this device in such cases.

  10. [Sport activity after hip and knee arthroplasty].

    Science.gov (United States)

    Keren, Amit; Berkovich, Yaron; Berkovitch, Yaron; Soudry, Michael

    2013-11-01

    Joint arthroplasty is one of the commonest surgical procedures in orthopedic surgery. In recent years there was an increase in the number of procedures, patient satisfaction and implant survival. Originally, these operations were designed for old patients in order to relieve pain and to enable ambulation. Over the past few years, these operations have become common in younger patients which desire to return to activity, including sports activities. The importance of physical activity is a well known fact. In recent years it became clear that with the proper physical activity the outcomes of the operations are better. There are several types of arthroplasty. Many factors influence the outcome of the operation apart from the post-surgery physical activity. These factors include patient factors, surgical technique and type of arthroplasty. This review summarizes the recommendations for sports activities after hip and knee arthroplasties. These activities are evaluated according to surgeons' recommendations, stress applied on the implant and long term outcomes. The recommended sports activities after joint arthroplasties are walking, swimming and cycling. Soccer, basketball and jogging are not advised. Tennis, downhill skiing and horse riding are recommended with previous experience. There are many more sports activities that patients can participate in, and it is important that the patient discuss the different options prior to the operation. Since these operations are so common, many non-orthopedic physicians encounter these patients in their practice. They should be acquainted with the recommendations for sports activities and encourage them.

  11. Clinicodemographic aspect of resectable pancreatic cancer and prognostic factors for resectable cancer

    Directory of Open Access Journals (Sweden)

    Chiang Kun-Chun

    2012-05-01

    Full Text Available Abstract Background Pancreatic adenocarcinoma (PCA is one of the most lethal human malignancies, and radical surgery remains the cornerstone of treatment. After resection, the overall 5-year survival rate is only 10% to 29%. At the time of presentation, however, about 40% of patients generally have distant metastases and another 40% are usually diagnosed with locally advanced cancers. The remaining 20% of patients are indicated for surgery on the basis of the results of preoperative imaging studies; however, about half of these patients are found to be unsuitable for resection during surgical exploration. In the current study, we aimed to determine the clinicopathological characteristics that predict the resectability of PCA and to conduct a prognostic analysis of PCA after resection to identify favorable survival factors. Methods We retrospectively reviewed the medical files of 688 patients (422 men and 266 women who had undergone surgery for histopathologically proven PCA in the Department of Surgery at Chang Gung Memorial Hospital in Taiwan from 1981 to 2006. We compared the clinical characteristics of patients who underwent resection and patients who did not undergo resection in order to identify the predictive factors for successful resectability of PCA, and we conducted prognostic analysis for PCA after resection. Results A carbohydrate antigen 19–9 (CA 19–9 level of 37 U/ml or greater and a tumor size of 3 cm or more independently predicted resectability of PCA. In terms of survival after resection, PCA patients with better nutritional status (measured as having an albumin level greater than 3.5 g/dl, radical resection, early tumor stage and better-differentiated tumors were associated with favorable survival. Conclusions Besides traditional imaging studies, preoperative CA 19–9 levels and tumor size can also be used to determine the resectability of PCA. Better nutritional status, curative resection, early tumor stage and well

  12. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty

    Science.gov (United States)

    Eaton, M. J.; Nutton, R. W.; Wade, F. A.; Evans, S. L.; Pankaj, P.

    2017-01-01

    Objectives Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). Materials and Methods A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed. Results Experimental AE data and the FEM volume of cancellous bone with compressive strain < -3000 µε correlated strongly: R = 0.947, R2 = 0.847, percentage error 12.5% (p < 0.001). DIC and FEM data correlated: R = 0.838, R2 = 0.702, percentage error 4.5% (p < 0.001). FEM strain patterns included MB lateral edge concentrations; AP concentrations at keel, peg and at the region of load application. Cancellous strains were higher in AP implants at all loads: 2.2- (10 mm) to 3.2-times (6 mm) the volume of cancellous bone compressively strained < -7000 µε. Conclusion AP tibial components display greater volumes of pathologically overstrained cancellous bone than MB implants of the same geometry. Increasing AP thickness does not overcome these pathological forces and comes at the cost of greater bone resection. Cite this article: C. E. H. Scott, M. J. Eaton, R. W. Nutton, F. A. Wade, S. L. Evans, P. Pankaj. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model. Bone Joint Res 2017;6:22–30. DOI:10

  13. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    Science.gov (United States)

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  14. Articulation of Native Cartilage Against Different Femoral Component Materials. Oxidized Zirconium Damages Cartilage Less Than Cobalt-Chrome.

    Science.gov (United States)

    Vanlommel, Jan; De Corte, Ronny; Luyckx, Jean Philippe; Anderson, Melissa; Labey, Luc; Bellemans, Johan

    2017-01-01

    Oxidized zirconium (OxZr) is produced by thermally driven oxidization creating an oxidized surface with the properties of a ceramic at the top of the Zr metal substrate. OxZr is much harder and has a lower coefficient of friction than cobalt-chrome (CoCr), both leading to better wear characteristics. We evaluated and compared damage to the cartilage of porcine patella plugs, articulating against OxZr vs CoCr. Our hypothesis was that, owing to its better wear properties, OxZr would damage cartilage less than CoCr. If this is true, OxZr might be a better material for the femoral component during total knee arthroplasty if the patella is not resurfaced. Twenty-one plugs from porcine patellae were prepared and tested in a reciprocating pin-on-disk machine while lubricated with bovine serum and under a constant load. Three different configurations were tested: cartilage-cartilage as the control group, cartilage-OxZr, and cartilage-CoCr. Macroscopic appearance, cartilage thickness, and the modified Mankin score were evaluated after 400,000 wear cycles. The control group showed statistically significant less damage than plugs articulating against both other materials. Cartilage plugs articulating against OxZr were statistically significantly less damaged than those articulating against CoCr. Although replacing cartilage by an implant always leads to deterioration of the cartilage counterface, OxZr results in less damage than CoCr. The use of OxZr might thus be preferable to CoCr in case of total knee arthroplasty without patella resurfacing. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. [Stress analysis of femoral stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer].

    Science.gov (United States)

    Oomori, H; Imura, S; Gesso, H

    1992-04-01

    To develop stem design achieving primary fixation of stems and effective load transfer to the femur, we studied stress analysis of stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer in stem-bone interface. The results of analyses of stem-bone interface stresses and von Mises stresses at the cortical bones indicated that ideal stem design features would be as follows: 1) Sufficient length, with the distal end extending beyond the isthmus region. 2) Maximum possible width, to contact the cortical bones in the isthmus region. 3) No collars but a lateral shoulder at the proximal portion. 4) A distal tip, to contact the cortical bones at the distal portion.

  16. Postoperative effects of neuromuscular exercise prior to hip or knee arthroplasty

    DEFF Research Database (Denmark)

    Villadsen, Allan; Overgaard, Søren; Holsgaard-Larsen, Anders

    2014-01-01

    neuromuscular exercise prior to total joint arthroplasty (TJA) of the hip or knee did not confer additional benefits 3 months postoperatively compared with TJA alone. However, the intervention group experienced a statistically significant short-term benefit in ADL and pain, suggesting an earlier onset......OBJECTIVE: To investigate the postoperative efficacy of a supervised programme of neuromuscular exercise prior to hip or knee arthroplasty. METHODS: In this assessor-blinded randomised controlled trial, we included 165 patients scheduled for hip or knee arthroplasty due to severe osteoarthritis (OA......). An 8-week preoperative neuromuscular supervised exercise programme was delivered twice a week for 1 h as adjunct treatment to the standard arthroplasty procedure and compared with the standard arthroplasty procedure alone. The primary outcome was self-reported physical function measured...

  17. Bone marrow aspirate concentrate in combination with intravenous iloprost increases bone healing in patients with avascular necrosis of the femoral head: a matched pair analysis

    Directory of Open Access Journals (Sweden)

    Hakan Pilge

    2017-01-01

    Full Text Available With disease progression, avascular necrosis (AVN of the femoral head may lead to a collapse of the articular surface. The exact pathophysiology of AVN remains unclear, although several conditions are known that can result in spontaneous cell death, leading to a reduction of trabecular bone and the development of AVN. Hip AVN treatment is stage-dependent in which two main stages of the disease can be distinguished: pre-collapse (ARCO 0-II and post-collapse stage (ARCO III-IV, crescent sign. In the pre-collapse phase, core decompression (CD, with or without the addition of bone marrow (e.g. bone marrow aspirate concentrate, BMAC or bone graft, is a common treatment alternative. In the postcollapse phase, THA (total hip arthroplasty must be performed in most of the patients. In addition to surgical treatment, the intravenous application of Iloprost has been shown to have a curative potential and analgesic effect. From October 2009 to October 2014, 49 patients with AVN (stages I-III were treated with core decompression at our institution. All patients were divided into group A (CD + BMAC and group B (CD alone. Of these patients, 20 were included in a matched pair analysis. The patients were matched to age, gender, ARCO-stage, Kerboul combined necrotic angle, the cause of AVN, and whether Iloprost-therapy was performed. The Merle d’Aubigné Score and the Kerboul combined necrotic angle in a-p and lateral radiographs were evaluated pre- and postoperatively. The primary endpoint was a total hip arthroplasty. In group A, two patients needed THA while in group B four patients were treated with THA. In group A, the Merle d’Aubigné Score improved from 13.5 (pre-operatively to 15.3 (postoperatively. In group B there was no difference between the pre- (14.3 and postoperative (14.1 assessment. The mean of the Kerboul angle showed no difference in both groups compared pre- to postoperatively (group A: pre-op 212°, postop 220°, group B: pre-op 213

  18. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1991-07-15

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side.

  19. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    International Nuclear Information System (INIS)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon

    1991-01-01

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side

  20. Humeral windows in revision total elbow arthroplasty.

    Science.gov (United States)

    Peach, Chris A; Salama, Amir; Stanley, David

    2016-04-01

    The use of cortical windows for revision elbow arthroplasty has not previously been widely reported. Their use aids safe revision of a well fixed humeral prosthesis and can be used in the setting of dislocation, periprosthetic fracture or aseptic loosening of the ulnar component. We describe our technique and results of cortical windows in the distal humerus for revision elbow arthroplasty surgery.