WorldWideScience

Sample records for femoral component loosening

  1. Femoral component loosening after hip resurfacing arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zustin, Jozef; Sauter, Guido [University Medical Centre Hamburg-Eppendorf, Institute of Pathology, Hamburg (Germany); Hahn, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); Morlock, Michael M. [TUHH Hamburg University of Technology, Biomechanics Section, Hamburg (Germany); Ruether, Wolfgang [University Medical Centre Hamburg-Eppendorf, Department of Orthopaedics, Hamburg (Germany); Amling, Michael [University Medical Centre Hamburg-Eppendorf, Center for Biomechanics and Skeletal Biology, Hamburg (Germany); University Medical Centre Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany)

    2010-08-15

    Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral

  2. Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening

    Directory of Open Access Journals (Sweden)

    Ashvin Thambyah

    2014-01-01

    Full Text Available Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, the shear reversal effect is discussed and simulated in a finite element knee implant-bone model, to evaluate the possible biomechanical significance of this effect on femoral component loosening of high flexion implants as reported in the literature. The analysis shows that one of the effects of the shear reversal was a switch between large compressive and large tensile principal strains, from knee extension to flexion, respectively, in the region of the anterior flange of the femoral component. Together with the known material limits of cement and bone, this large mismatch in strains as a function of knee position provides new insight into how and why knee implants may fail in patients who perform frequent squatting.

  3. Arthroscopic observation was useful to detect loosening of the femoral component of unicompartmental knee arthroplasty in a recurrent hemoarthrosis

    Directory of Open Access Journals (Sweden)

    Yamakado Kotaro

    2012-02-01

    Full Text Available Abstract A case of recurrent hemarthrosis of the knee after a mobile-bearing unicompartmental knee arthroplasty (UKA; Oxford UKA is described. A 58-year-old man met with a road traffic accident 10 months after UKA. He developed anteromedial pain and hemarthrosis of the knee joint 1 month after the accident, which required multiple aspirations. Physical examination showed no instability. Plain radiograph revealed no signs of loosening. All laboratory data, including bleeding and coagulation times, were within normal limits. Diagnostic arthroscopy demonstrated loosening of the femoral component. Any intraarticular pathology other than nonspecific synovitis was ruled out. The loose femoral component and polyethylene meniscal bearing were revised. Since then, hemarthrosis has not recurred.

  4. Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques

    NARCIS (Netherlands)

    van de Groes, S.A.W.; De Waal Malefijt, M.C.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background: Some follow-up studies of highflexion total knee arthoplasties report disturbingly high incidences of femoral component loosening. Femoral implantfixation is dependant on two interfaces: the cement–implant and the cement–bone interface. The present finite-element model (FEM) is the first

  5. Probability of mechanical loosening of the femoral component in high flexion total knee arthroplasty can be reduced by rather simple surgical techniques

    NARCIS (Netherlands)

    Groes, S.A.W. van de; Waal Malefijt, M.C. de; Verdonschot, N.J.J.

    2014-01-01

    BACKGROUND: Some follow-up studies of high flexion total knee arthoplasties report disturbingly high incidences of femoral component loosening. Femoral implant fixation is dependant on two interfaces: the cement-implant and the cement-bone interface. The present finite-element model (FEM) is the

  6. Arthroscopic observation was useful to detect loosening of the femoral component of unicompartmental knee arthroplasty in a recurrent hemoarthrosis

    OpenAIRE

    Yamakado Kotaro; Arakawa Hitoshi; Hayashi Seigaku

    2012-01-01

    Abstract A case of recurrent hemarthrosis of the knee after a mobile-bearing unicompartmental knee arthroplasty (UKA; Oxford UKA) is described. A 58-year-old man met with a road traffic accident 10 months after UKA. He developed anteromedial pain and hemarthrosis of the knee joint 1 month after the accident, which required multiple aspirations. Physical examination showed no instability. Plain radiograph revealed no signs of loosening. All laboratory data, including bleeding and coagulation t...

  7. Pigmented villonodular synovitis after TKA associated with tibial component loosening.

    Science.gov (United States)

    Chung, Byung June; Park, Yong Bum

    2011-08-08

    There is no known causal link between total knee arthroplasty (TKA) and pigmented villonodular synovitis (PVNS). There also is no known relationship between PVNS and implant loosening after TKA in the literature. This article presents a case of PVNS in a patient undergoing revision TKA for tibial component loosening. A 74-year-old woman who had undergone cemented bilateral TKA 5 years earlier presented with painful swelling in her right knee. At the time of the primary TKA, no abnormal signs were found in the synovial membrane. Routine follow-up radiographs did not indicate implant loosening. At the patient's final follow-up examination before revision surgery, a radiolucent lesion was found below the tibial component. During revision surgery, there was focal proliferation of the synovial tissue with heavy pigmentation around the anteromedial part of the tibial component. The abnormal tissue was removed, and the tibial component was exchanged. The articular surface of the polyethylene was not damaged, and backside wear was not found. For the revision surgery, 5-mm thick medial metal block and extension stem were used. Histological analysis of the resected tissue revealed the typical appearance of PVNS. We present a typical case of PVNS found during revision TKA 5 years after primary TKA. It is hoped this report will encourage surgeons to consider PVNS in the differential diagnosis of patients who present with painful swelling of the knee and to consider PVNS as one of the causes of implant loosening after TKA. Further research about causal factors between PVNS and implant loosening are needed. Copyright 2011, SLACK Incorporated.

  8. Radiotherapy inducing total knee prosthetic component loosening for recurrent pigmented villonodular synovitis following joint replacement

    Directory of Open Access Journals (Sweden)

    Ko-Ta Chen

    2017-01-01

    Full Text Available Pigmented villonodular synovitis (PVNS following total knee arthroplasty (TKA is a rare condition. We reported a case of PVNS following TKA; initially, arthroscopic synovectomy was performed; however, recurrence of PVNS happened. We performed second arthroscopic synovectomy and moderate dose radiotherapy (total dose 44 cGy/22 fractions to posterior fossa, 36 cGy/18 fractions to knee for the patient. Unfortunately, distal femur osteonecrosis with femoral and tibial component loosening happened 2 months after completing the radiotherapy procedure. Revision TKA with Legacy Constrained Condylar Knee was done. Radiotherapy is not recommended for recurrent PVNS after TKA.

  9. Extensively Coated Cementless Femoral Components in Revision Hip Arthroplasty.

    Science.gov (United States)

    Greidanus, Nelson; Antoniou, John; Paprosky, Wayne

    2000-10-01

    A septic loosening and osteolysis can compromise the available host bone in patients requiring revision hip arthroplasty. Secure fixation of revision femoral components may not be possible if reliant only on proximal femoral bone for biologic fixation or cement interdigitation. The challenge for the revision arthroplasty surgeon is to find the best method to secure the implant in a femur with deficient bone proximally that will provide stability for load bearing and motion. In addition to providing stability, the implant must be durable and maintain long-term fixation. With over 16 years of experience with fully porous coated femoral revision implants, we have found that maximizing prosthetic-bone fit in the proximal femoral diaphyseal bone provides reliable long-term fixation in the majority of femoral revision cases.

  10. Postmortem retrieved canine THR: femoral and acetabular component interaction.

    Science.gov (United States)

    Skurla, Carolyn P; James, Susan P

    2004-01-01

    Dogs are the preferred animal model for testing of human total hip replacements (THRs). A postmortem retrieval program for clinical, cemented, canine THR was established to analyze the long-term performance of THRs in dogs and to compare that performance to postmortem retrievals of human THRs. The purpose of the present study was to analyze the interaction between the femoral and acetabular components. Thirty-eight postmortem retrievals from 29 dogs were donated and analyzed. The acetabular components (ACs) were measured for volumetric wear and graded for articulating surface damage. Femoral and acetabular components were mechanically tested for implant stability. Digital image analysis was performed on contact radiographs of transverse femoral slices. Of 14 cases with a firmly implanted femoral component (FC). 6 articulated against loose ACs. Of 24 cases with a loose FC, 16 articulated against loose ACs. Only 4 specimens had both components firmly implanted, and 14 specimens had both components loose. There was a significant positive correlation between AC volumetric wear and FC loosening; however, there was no evidence of osteolysis or wear debris induced osteolysis as seen in human postmortem retrieval studies. There was a significant but weak negative correlation between FC loosening at the cement/bone interface and AC scores reflecting damage to the rim and creep across the entire AC. Although implant-on-implant damage to the AC was expected to positively correlate with FC loosening, this was not found. Researchers need to look at interactions between AC and FC to understand how the failure of one component affects performance of the other.

  11. Femoral revision with impaction allografting and an uncemented femoral component

    DEFF Research Database (Denmark)

    Nickelsen, T N; Erenbjerg, M; Retpen, J B

    2008-01-01

    implants 88% had no pain, 10% had slight pain and only 2% had severe pain. Thirty-eight patients had radiographic signs of remodelling of the graft and/or cortical repair. In cases with a successful outcome, the results have been encouraging in relation to clinical performance, regeneration of bone...... component revision for aseptic loosening was performed on 100 hips. In 14 cases (14%) an intraoperative fracture occurred and 7 patients (7%) had other postoperative complications. Seventeen patients (17%) required further revision, 10 because of aseptic loosening. Of 50 surviving patients with retained...

  12. Influence of a secondary downsizing of the femoral component on the extension gap: a cadaveric study.

    Science.gov (United States)

    Sriphirom, Pornpavit; Raungthong, Nathee; Chutchawan, Pirapon; Thiranon, Chaiyot; Sukandhavesa, Nantawit

    2012-10-01

    The purpose of this study was to evaluate the effect of a secondary reduction of the femoral component size on flexion and extension gaps intraoperatively in posterior-stabilized total knee arthroplasty (PS-TKA) monitored by computer-assisted surgery. The authors hypothesized that cutting additional bone on the posterior femoral condyle may increase the extension gap due to the posterior capsule and soft tissue loosening. Reduction of the femoral component size was performed by additional 4-in-1 cuts after the PS-TKA on 15 cadaveric knees using a ligamentous tension device with the aid of computer-assisted surgery. Measurements of the medial and lateral flexion gaps, as well as the medial and lateral extension gaps, were recorded before and after reducing the femoral component size. Trial components were used from a mobile-bearing total knee system.After reducing the femoral component size, the medial and lateral flexion and extension gaps measured larger than their initial size. The mean increases of the medial extension and flexion gaps and the lateral extension and flexion gaps were 1.3 ± 0.9, 1.0 ± 1.2, 1.1 ± 1.2, and 1.3 ± 1.3 mm, respectively; all 4 differences were significant (P ≤ .05). Surgeons should be aware of the effect of downsizing components intraoperatively because it might lead to an extension laxity. Thus, a downsizing of the femoral component may compromise the postoperative stability of TKA.

  13. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up.

    Science.gov (United States)

    Callaghan, John J; Liu, Steve S; Firestone, Daniel E; Yehyawi, Tameem M; Goetz, Devon D; Sullivan, Jason; Vittetoe, David A; O'Rourke, Michael R; Johnston, Richard C

    2008-02-01

    In the mid- to late 1970s, on the basis of laboratory and finite element data, many surgeons in the United States began using collared matte-finish femoral components and metal-backed acetabular components in their total hip arthroplasties. The purpose of this study was to evaluate the long-term results of the use of one such construct in arthroplasties performed by a single surgeon in a consecutive nonselected patient cohort. Between January 1984 and December 1985, 273 patients underwent a total of 304 consecutive nonselected total hip arthroplasties with cement and use of the Iowa femoral component (which is collared, has a proximal cobra shape, and has a matte finish) and a metal-backed TiBac acetabular component performed by a single surgeon. At nineteen to twenty years postoperatively, only two patients (two hips) were lost to follow-up. For clinical evaluation, we attempted to interview all living patients and the families of the patients who had died to verify the status of the hip prosthesis or any revisions. Radiographic evaluation consisted of analysis for loosening and osteolysis as well as wear of the acetabular component. At the time of the nineteen to twenty-year follow-up, the rate of revision of the arthroplasty for any reason was 10.5% (thirty-two hips) for all patients and 25% (twenty-three hips) for living patients. The rate of revision due to aseptic femoral loosening was 2.6% (eight hips). There was radiographic evidence of loosening of the femoral component in fifteen hips (4.9%), including those that were revised, and femoral osteolysis was seen distal to the trochanters in twenty-two hips (7.2%). The rate of revision due to aseptic loosening of the acetabular component was 7.9% (twenty-four hips), and there was radiographic evidence of acetabular loosening in forty-two hips (13.8%), including those that were revised. This study demonstrates the durability of a cemented matte-finish collared femoral component at twenty years postoperatively

  14. Long-term implant-bone fixation of the femoral component in total knee replacement.

    Science.gov (United States)

    Cristofolini, L; Affatato, S; Erani, P; Leardini, W; Tigani, D; Viceconti, M

    2008-04-01

    Success of total knee replacement (TKR) depends on the prosthetic design. Aseptic loosening of the femoral component is a significant failure mode that has received little attention. Despite the clinical relevance of failures, no protocol is available to test long-term implant-bone fixation of TKR in vitro. The scope of this work was to develop and validate a protocol to assess pre-clinically the fixation of TKR femoral components. An in vitro protocol was designed to apply a simplified but relevant loading profile using a 6-degrees-of-freedom knee simulator for 1,000000 cycles. Implant-bone inducible micromotions and permanent migrations were measured at three locations throughout the test. After test completion, fatigue damage in the cement was quantified. The developed protocol was successfully applied to a commercial TKR. Additional tests were performed to exclude artefacts due to swelling or creep of the composite femur models. The components migrated distally; they tilted towards valgus in the frontal plane and in extension in the sagittal plane. The migration patterns were consistent with clinical roentgen-stereophotogrammetric recordings with TKR. Additional indicators were proposed that could quantify the tendency to loosen/stabilize. The type and amount of damage found in the cement, as well as the migration patterns, were consistent with clinical experience with the specific TKR investigated. The proposed pre-clinical test yielded repeatable results, which were consistent with the clinical literature. Therefore, its relevance and reliability was proved.

  15. Revisões femorais de artroplastias totais do quadril com afrouxamentos assépticos e fraturas periprotéticas: análise de 49 casos tratados com haste de Wagner Femoral revision total hip arthroplasties with aseptic loosening and periprosthetic fractures: analysis of 49 cases treated with Wagner stem

    Directory of Open Access Journals (Sweden)

    Sergio Nogueira Drumond

    2007-07-01

    Full Text Available OBJETIVO: Avaliar 49 quadris em 48 pacientes submetidos a revisão de artroplastia total do quadril usando a haste de Wagner. MÉTODOS: De abril de 1999 a janeiro de 2005, foram tratados 49 quadris em pacientes portadores de afrouxamento femoral (39 quadris ou fratura periprotética do fêmur (10 quadris com revisão da artroplastia com a prótese de Wagner. O seguimento médio foi de 35 meses e a média de idade, de 63,4 anos. As revisões do componente femoral foram realizadas em 49 quadris e, simultaneamente, no componente acetabular em 36 quadris. RESULTADOS: A avaliação dos resultados pelo índice de D'Aubignè-Postel-Charnley apresentou melhora estatisticamente significante no pós-operatório em relação ao pré-operatório (p OBJECTIVE: To evaluate 49 hips in 48 patients submitted to revision total hip arthroplasty using Wagner stem. METHODS: From April 1999 to January 2005, 49 hips were treated in patients with femoral loosening (39 hips or periprosthetic fracture of the femur (10 hips with revision arthroplasty using the Wagner prosthesis. Mean follow-up lasted 35 months and mean age was 63.4 years. Revisions of the femoral component were performed in 49 hips, with concomitant acetabular component revision in 36 hips. RESULTS: Results evaluation according to the D'Aubignè-Postel-Charnley index presented a statistically significant improvement in the post-operative period in comparison to the pre-operative period (p < 0.001. The most important problems seen were the high rate of dislocations (three hips and dislocations associated to the deepening of the stem (two hips. The four unsatisfactory results were due to loosening (two hips, infection (one hip, and acetabular loosening (one hip. All of the unsatisfactory results occurred in the group of aseptic loosening, but this finding was not statistically significant (p = 0.569. Restoration of bone stock (radiographic evaluation was seen consistently in most cases, without correlation

  16. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design...... osteolysis associated with a deep infection, but no signs of proximal loosening. 3 femora had areas of minor proximal osteolysis. 16 acetabular components (14 threaded) had been revised in 13 patients. The average Harris hip score was 91 points at the latest follow-up. We conclude that the uncemented...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  17. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design...... osteolysis associated with a deep infection, but no signs of proximal loosening. 3 femora had areas of minor proximal osteolysis. 16 acetabular components (14 threaded) had been revised in 13 patients. The average Harris hip score was 91 points at the latest follow-up. We conclude that the uncemented...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  18. Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component.

    Science.gov (United States)

    Clauss, Martin; Van Der Straeten, Catherine; Goossens, Marc

    2014-01-01

    Early subsidence >1.5 mm is considered to be a predictive factor for later aseptic loosening of the femoral component following total hip arthroplasty (THA). The aim of this study was to assess five-year subsidence rates of the cementless hydroxyapatite-coated twinSys stem (Mathys Ltd., Bettlach, Switzerland).This prospective single-surgeon series examined consecutive patients receiving a twinSys stem at Maria Middelares Hospital, Belgium. Patients aged >85 years or unable to come to follow-up were excluded. Subsidence was assessed using Ein Bild Roentgen Analyse--Femoral Component Analysis (EBRA-FCA). Additional clinical and radiographic assessments were performed. Follow-ups were prospectively scheduled at two, five, 12, 24, and 60 months.In total, 218 THA (211 patients) were included. At five years, mean subsidence was 0.66 mm (95% CI: 0.43-0.90). Of the 211 patients, 95.2% had an excellent or good Harris Hip Score. There were few radiological changes. Kaplan-Meier analysis indicated five-year stem survival to be 98.4% (95% CI: 97.6-100%).Subsidence levels of the twinSys femoral stem throughout the five years of follow-up were substantially lower than the 1.5 mm level predictive of aseptic loosening. This was reflected in the high five-year survival rate.

  19. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Zhipeng [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Huang, Bingxue; Li, Yiwen [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China); Tian, Meng [Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041 (China); Li, Li [Department of Oncology, the 452 Hospital of Chinese PLA, Chengdu 610021 (China); Yu, Xixun, E-mail: yuxixun@163.com [College of Polymer Science and Engineering, Sichuan University, Chengdu 610065 (China)

    2016-04-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening. - Highlights: • SCPP/UHMWPE composites could enhance biological efficacy of resistance to aseptic loosening. • SCPP would improve biological efficacy with a few sacrifice of wear resistance. • The results might provide a promising wear-resistant material for fabricating acetabular cup.

  20. Early micromovement of the Articular Surface Replacement (ASR) femoral component

    DEFF Research Database (Denmark)

    Penny, J O; Ding, M; Varmarken, J E;

    2012-01-01

    Radiostereometric analysis (RSA) can detect early micromovement in unstable implant designs which are likely subsequently to have a high failure rate. In 2010, the Articular Surface Replacement (ASR) was withdrawn because of a high failure rate. In 19 ASR femoral components, the mean micromovemen...

  1. Analysis of Femoral Components of Cemented Total Hip- Arthroplasty

    CERN Document Server

    Singh, Shantanu

    2014-01-01

    In cemented Total Hip Arthroplasty (THA), material chosen for femoral stem and cross section of stem itself, proved to be critical parameters for, stress distribution in the femoral components, interfacial stresses and micro movements. Titanium alloy (Ti6Al4V), when used as a material for femoral stem, recorded large displacement as compared to Chromium alloy (CoCrMo) stems. This large displacement in case of Ti6Al4V caused the stem to bend inside the cement mantle, thus destroying it. Thus, CoCrMo proved to be a better in cemented THA. Failure in THA may occur at cement-stem or cement-bone interface, thus interfacial stresses and micro movements were analysed in the present study. Comparison between trapezium and circular cross section showed that, femoral stem with trapezium cross section underwent lesser amount of sliding and debonding, at both interfaces, as compared to circular cross section. Moreover, trapezium cross section also generated lower peak stresses in femoral stem and cortical femur. The pres...

  2. Combined use of extensively porous coated femoral components with onlay cortical strut allografts in revision of Vancouver B2 and B3 periprosthetic femoral fractures

    Institute of Scientific and Technical Information of China (English)

    WU Hao-bo; YAN Shi-gui; WU Li-dong; HE Rong-xin; WANG Xiang-hua; DAI Xue-song

    2009-01-01

    Background Periprosthetic femoral fractures following total hip arthroplasty are getting more prevalent.The aim of this study was to evaluate the clinical results of combined use of uncemented extensively porous coated femoral components with onlay cortical strut allografts in revision of Vancouver type B2 and B3 periprosthetic femoral fractures.Methods Thirteen hips after total hip arthroplasty in 13 patients who suffered a Vancouver B2 or B3 periprosthetic fracture were treated with an uncemented extensively porous coated femoral component combined with onlay cortical strut allografts.Each patient was assigned a Harris hip score,and a visual analog scale(VAS)score for pain and satisfaction.Radiographs were examined for component stability,fracture site and allograft-host union and allograft reconstruction.Results At an average of 5.3-year follow-up,no patient required repeat revision.The average Harris hip score was(71.8±6.3)points,the pain VAS score was(16.6±4.3)points,and the patient satisfaction VAS score was(81.5±5.7)points.Radiographic examination showed no detectable loosening of the prostheses,and 12 cases were presented fixation by osseointegration and the other one was stable fibrous ingrown fixation.All fractures united for(5.2±1.4)months in average.And all onlay strut allografts united to host bone for about(11.5±2.6)months.Conclusions Combined use of uncemented,long stemmed,extensively porous coated implant with cortical onlay strut allografts can achieve good clinic results and high rate of union for both fracture site and allograft-host bone junction.This technique could be used routinely to augment fixation and healing of Vancouver B2 and B3 periprosthetic fractures.

  3. Strontium-doped calcium polyphosphate/ultrahigh molecular weight polyethylene composites: A new class of artificial joint components with enhanced biological efficacy to aseptic loosening.

    Science.gov (United States)

    Gu, Zhipeng; Huang, Bingxue; Li, Yiwen; Tian, Meng; Li, Li; Yu, Xixun

    2016-04-01

    To enhance implant stability and prolong the service life of artificial joint component, a new approach was proposed to improve the wear resistance of artificial joint component and endow artificial joint component with the biological efficacy of resistance to aseptic loosening. Strontium calcium polyphosphate (SCPP) were interfused in ultrahigh molecular weight polyethylene (UHMWPE) by a combination of liquid nitrogen ball-milling and flat-panel curing process to prepare the SCPP/UHMWPE composites. The micro-structure, mechanical characterization, tribological characterization and bioactivities of various SCPP/UHMWPE composites were investigated. The results suggested that this method could statistically improve the wear resistance of UHMWPE resulting from a good SCPP particle dispersion. Moreover, it is also observed that the SCPP/UHMWPE composites-wear particles could promote the production of OPG by osteoblasts and decrease the production of RANKL by osteoblasts, and then increase the OPG/RANKL ratio. This indicated that the SCPP/UHMWPE composites had potential efficacy to prevent and treat aseptic loosening. Above all, the SCPP/UHMWPE composites with a suitable SCPP content would be the promising materials for fabricating artificial joint component with ability to resist aseptic loosening.

  4. DLC screw preload. Loosening prevention

    Directory of Open Access Journals (Sweden)

    Ivete Aparecida de Mattias Sartori

    2008-01-01

    Full Text Available The screw loosening is a reason to prosthetic rehabilitation failure. However, the DLC (Diamond-like carbon screw treatment lead thefriction decrease and sliding between the components, which increases the screw preload benefit and decreases the chance of looseningoccurrence. This case shows a clinical indication of the association of the correct preload applied and the DLC screw, which can be considered an optimized protocol to solve screw loosening recidivate of unitary prosthesis in anterior maxillary site.

  5. Effect of surgeon experience on femoral component size selection during total knee arthroplasty.

    Science.gov (United States)

    Nandi, Sumon; Bono, James V; Froimson, Mark; Jones, Morgan; Bershadsky, Boris

    2013-01-01

    Femoral component size selection during total knee arthroplasty should not vary from surgeon to surgeon for patients with the same bone size. This study explored if systematic variations in femoral component size selection exist. Thirteen surgeons' choices of femoral component size (Duracon, n = 1388; Triathlon, n = 740) were analyzed using a generalized linear model with femoral component size as the dependent variable and surgeon identification, years in practice, and adult reconstruction fellowship training as the independent variables. The model adjusted for differences in bone size. It was found that more experienced surgeons implant larger femoral components. New instruments and training protocols may be necessary to adjust for surgeon experience.

  6. The effect of femoral neck osteotomy on femoral component position of a primary cementless total hip arthroplasty.

    Science.gov (United States)

    Dimitriou, Dimitris; Tsai, Tsung-Yuan; Kwon, Young-Min

    2015-12-01

    The aim of this study was to quantify the femoral canal diameter and version at different femoral neck osteotomy locations, and to investigate the effect of the osteotomy plane on femoral component position in total hip arthroplasty (THA). Preoperative and postoperative three-dimensional models were reconstructed in 15 patients (19 hips) who underwent primary cementless THA with tapered non-anatomical femoral stem. On the pre-operative models, the osteotomy plane was simulated at different levels (-5, 0, 5, and 10 mm from the femoral saddle [piriformis fossa]) and angles (30, 40, 50, and 60° from the femoral anatomical axis). Medullary canal version and mediolateral diameter were measured on the osteotomy surfaces. On the postoperative models, the femoral neck osteotomy plane, stem anteversion and alignment were measured. The average canal diameter ranged from 22.8 to 26.3 mm at different osteotomy levels and from 20.8 to 29.0 mm at different osteotomy angles. The average canal version ranged from 11.4 to 23.2° at different resection levels and from 12.8 to 21° at different resection angles. The femoral stem anteversion was correlated with neck osteotomy angle (R = 0.72), whereas stem alignment in frontal plane (varus/valgus) was correlated with neck osteotomy level (R = 0.87). The femoral neck osteotomy plane in THA affects the postoperative stem position due to the complex morphology of the proximal femoral medullary canal, suggesting that both femoral neck resection level and angle should be considered in optimizing femoral component alignment in THA patients.

  7. Topographical analysis of the femoral components of ex vivo total knee replacements.

    Science.gov (United States)

    Scholes, Susan C; Kennard, Emma; Gangadharan, Rajkumar; Weir, David; Holland, Jim; Deehan, David; Joyce, Thomas J

    2013-02-01

    With greater numbers of primary knee replacements now performed in younger patients there is a demand for improved performance. Surface roughness of the femoral component has been proposed as a causative mechanism for premature prosthesis failure. Nineteen retrieved total knee replacements were analysed using a non-contacting profilometer to measure the femoral component surface roughness. The Hood technique was used to analyse the wear and surface damage of the matching ultra-high molecular weight polyethylene (UHMWPE) tibial components. All femoral components were shown to be up to 11× rougher after their time in vivo while 95 % showed a change in skewness, further indicating wear. This increase in roughness occurred relatively soon after implantation (within 1 year) and remained unchanged thereafter. Mostly, this roughness was more apparent on the lateral condyle than the medial. This increased femoral surface roughness likely led to damage of the UHMWPE tibial component and increased Hood scores.

  8. Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty.

    Science.gov (United States)

    Boldt, J G; Stiehl, J B; Hodler, J; Zanetti, M; Munzinger, U

    2006-10-01

    The purpose of this study was to evaluate the femoral component rotation in a small subset of patients who had developed arthrofibrosis after mobile-bearing total knee arthroplasty (TKA). Arthrofibrosis was defined as flexion less than 90 degrees or a flexion contracture greater than 10 degrees following TKA. From a consecutive cohort of 3,058 mobile-bearing TKAs, 49 (1.6%) patients were diagnosed as having arthrofibrosis, of which 38 (86%) could be recruited for clinical assessment. Femoral rotation of a control group of 38 asymptomatic TKA patients matched for age, gender, and body mass index was also evaluated. The surgical epicondylar axis was compared with the posterior condylar axis for the femoral prosthesis. Femoral components in the arthrofibrosis group were significantly internally rotated by a mean of 4.7 degrees (SD 2.2 degrees , range 10 degrees internal to 1 degrees external). In the control group, the femoral component had a mean 0.3 degrees internal rotation (SD 2.3 degrees , range 4 degrees internal to 6 degrees external). Following mobile-bearing TKA, there is a significant correlation between internal femoral component rotation and chronic arthrofibrosis.

  9. Coupling failure between stem and femoral component in a constrained revision total knee arthroplasty.

    LENUS (Irish Health Repository)

    Butt, Ahsan Javed

    2013-02-01

    Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use of a cemented femoral stem, screw fixation and the metaphyseal sleeve of an S-ROM modular hip system (DePuy international Ltd).

  10. Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

    Directory of Open Access Journals (Sweden)

    Nayfeh Jamal F

    2007-09-01

    Full Text Available Abstract Background Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-implant interface design has historically been limited by the surgical tools and cutting guides available; and the cost of fabricating custom-designed implant components has been prohibitive. Methods This paper describes an approach where the custom design is based on a Computed Tomography scan of the patient's joint. The proposed design will customize both the articulating surface and the bone-implant interface to address the most common problems found with conventional knee-implant components. Finite Element Analysis is used to evaluate and compare the proposed design of a custom femoral component with a conventional design. Results The proposed design shows a more even stress distribution on the bone-implant interface surface, which will reduce the uneven bone remodeling that can lead to premature loosening. Conclusion The proposed custom femoral component design has the following advantages compared with a conventional femoral component. (i Since the articulating surface closely mimics the shape of the distal femur, there is no need for resurfacing of the patella or gait change. (ii Owing to the resulting stress distribution, bone remodeling is even and the risk of premature loosening might be reduced. (iii Because the bone-implant interface can accommodate anatomical abnormalities at the distal femur, the need for surgical interventions and fitting of filler components is reduced. (iv Given that the bone-implant interface is customized, about 40% less bone must be removed. The primary disadvantages are the time and cost required for the

  11. The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements

    Energy Technology Data Exchange (ETDEWEB)

    Decking, J. [Dept. of Orthopaedic Surgery, Univ. of Mainz School of Medicine, Mainz (Germany); Schuetz, U.; Decking, R.; Puhl, W. [Orthopaedic Dept., Univ. of Ulm, School of Medicine (Germany)

    2003-09-01

    Objective: To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs. Design and patients: Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery. Results and conclusions: The UMA software measured the subsidence of the stems with an accuracy of {+-}2.5 mm and varus-valgus tilt with an accuracy of {+-}1.8 (95% confidence interval). A good interobserver and intraobserver reliability was calculated with Cronbach's alpha ranging from 0.86 to 0.97. Measuring the subsidence of THR stems within the femur is an important parameter in the diagnosis of implant loosening. Software systems such as UMA improve the accuracy of migration measurements and are easy to use on routinely performed radiographs of operated hip joints. (orig.)

  12. Management of peri-prosthetic fracture of the humerus with severe bone loss and loosening of the humeral component after total shoulder replacement.

    Science.gov (United States)

    Sewell, M D; Kang, S N; Al-Hadithy, N; Higgs, D S; Bayley, I; Falworth, M; Lambert, S M

    2012-10-01

    There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively. There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.

  13. Computer navigation experience in hip resurfacing improves femoral component alignment using a conventional jig

    Directory of Open Access Journals (Sweden)

    Zachary Morison

    2013-01-01

    Full Text Available Background:The use of computer navigation has been shown to improve the accuracy of femoral component placement compared to conventional instrumentation in hip resurfacing. Whether exposure to computer navigation improves accuracy when the procedure is subsequently performed with conventional instrumentation without navigation has not been explored. We examined whether femoral component alignment utilizing a conventional jig improves following experience with the use of imageless computer navigation for hip resurfacing. Materials and Methods:Between December 2004 and December 2008, 213 consecutive hip resurfacings were performed by a single surgeon. The first 17 (Cohort 1 and the last 9 (Cohort 2 hip resurfacings were performed using a conventional guidewire alignment jig. In 187 cases, the femoral component was implanted using the imageless computer navigation. Cohorts 1 and 2 were compared for femoral component alignment accuracy. Results:All components in Cohort 2 achieved the position determined by the preoperative plan. The mean deviation of the stem-shaft angle (SSA from the preoperatively planned target position was 2.2° in Cohort 2 and 5.6° in Cohort 1 ( P = 0.01. Four implants in Cohort 1 were positioned at least 10° varus compared to the target SSA position and another four were retroverted. Conclusions: Femoral component placement utilizing conventional instrumentation may be more accurate following experience using imageless computer navigation.

  14. External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty.

    Science.gov (United States)

    Terashima, Takashi; Onodera, Tomohiro; Sawaguchi, Naohiro; Kasahara, Yasuhiko; Majima, Tokifumi

    2015-11-01

    The purpose of this study was to investigate the relationship between patellofemoral (PF) contact stress in vivo and the alignment of the femoral component in patients after total knee arthroplasty (TKA). Thirty knees with medial compartment osteoarthritis that underwent mobile-bearing TKA with modified gap technique were evaluated. Surgery was performed using a subvastus approach to eliminate the effect of the approach to muscle balance, with a computed tomography-based navigation system (Vector Vision 1.61; Brain Lab, Heimstetten, Germany). PF contact stress was measured by a Flexiforce pressure sensor (Nitta Co., Ltd., Osaka, Japan) intraoperatively, and the results were compared with the alignment of the femoral component after TKA. The PF contact stress was not correlated with sagittal and coronal alignment of the femoral component and patellar tracking, whereas rotational alignment of the femoral component was negatively correlated with PF contact stress (r = -0.718, p correlated with PF contact stress. PF contact stress decreased more as the femoral component rotated more externally. Case control study, Level III.

  15. The influence of malrotation and femoral component material on patellofemoral wear during gait.

    Science.gov (United States)

    Vanbiervliet, J; Bellemans, J; Verlinden, C; Luyckx, J P; Labey, L; Innocenti, B; Vandenneucker, H

    2011-10-01

    Complications involving the patellofemoral joint, caused by malrotation of the femoral component during total knee replacement, are an important cause of persistent pain and failure leading to revision surgery. The aim of this study was to determine and quantify the influence of femoral component malrotation on patellofemoral wear, and to determine whether or not there is a difference in the rate of wear of the patellar component when articulated against oxidised zirconium (OxZr) and cobalt-chrome (CoCr) components. An in vitro method was used to simulate patellar maltracking for both materials. Both rates of wear and changes in height on the patellar articular surface were measured. The mean rates of wear measured were very small compared to standard tibiofemoral wear rates. When data for each femoral component material were pooled, the mean rate of wear was 0.19 mm3/Mcycle (sd 0.21) for OxZr and 0.34 mm3/Mcycle (sd 0.335) for CoCr. The largest change in height on each patella varied from -0.05 mm to -0.33 mm over the different configurations. The results suggest that patellar maltracking due to an internally rotated femoral component leads to an increased mean patellar wear. Although not statistically significant, the mean wear production may be lower for OxZr than for CoCr components.

  16. Improved femoral component rotation in TKA using patient-specific instrumentation.

    Science.gov (United States)

    Heyse, Thomas J; Tibesku, Carsten O

    2014-01-01

    Patient-specific instrumentation (PSI) was introduced in an attempt to reduce positional outliers of components in total knee arthroplasty (TKA). It was hypothesized that PSI could help with the positioning of femoral components in optimal rotational alignment. A magnetic resonance imaging (MRI) analysis of 94 patients following TKA was conducted. Of these, 46 operations were performed using PSI and 48 using conventional instrumentation. The rotation of the femoral components was determined in the MRI and deviations>3° were considered outliers. Data were analyzed for positional outliers, observer reliability, and a variance comparison between implant groups. There was excellent inter- and intraobserver reliability with low standard deviations for the determination of femoral component rotation. There were significantly more outliers in the conventional (22.9%) group than in the PSI group (2.2%, p=0.003). In this setup, PSI was effective in significantly reducing outliers of optimal rotational femoral component alignment during TKA. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Do Rerevision Rates Differ After First-time Revision of Primary THA With a Cemented and Cementless Femoral Component?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Pedersen, Alma B; Overgaard, Søren

    2015-01-01

    the results of future revision procedures; however, this has not been documented. The purpose of this study was to compare (1) the risk for rerevision of first revision THA; (2) the patterns of femoral bone loss at the time of first revision of primary THA; (3) the reasons for first revision of primary THA......; and (4) the time to first revision of primary THA between primary cementless and cemented femoral components. Primary THAs with cemented (n = 1791) and uncemented (n = 805) femoral components that subsequently sustained first revision of the femoral component were identified from the Danish Hip...... Arthroplasty Registry (DHR). As of 2012, 120,988 primary THAs and 19,282 revisions were registered in the DHR with completeness of 97% and 90% for primary and revision THA, respectively. Median followup for revisions of primary THA with cemented and cementless femoral component was 4 years (range, 0-17 years...

  18. Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

    Science.gov (United States)

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Howie, Donald W

    2016-06-30

    A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

  19. Reduced UHMWPE wear using magnesia-stabilized zirconia instead of CoCr femoral components in a knee simulator.

    Science.gov (United States)

    Roy, Marcel E; Whiteside, Leo A; Tilden, David S; Noel, Oscar F

    2015-03-01

    Magnesia-stabilized zirconia (Mg-PSZ) is stable and maintains a scratch-resistant surface in hip replacement, but is untested in knees. We assessed whether using Mg-PSZ instead of cobalt-chromium (CoCr) femoral components resulted in less tibial insert wear, and evaluated changes in topography and roughness of the femoral components. Inserts bearing against CoCr or Mg-PSZ were tested using standard (9 Mc) and aggressive (6 Mc) waveforms. Femoral component surface topography and roughness were evaluated before and after testing by optical profilometry. When bearing against Mg-PSZ, UHMWPE wear rate decreased by 73% (standard) and by 59% (aggressive conditions). After 15 Mc, CoCr components featured deep scratches, and roughness increased five-fold, while Mg-PSZ components were unchanged. Mg-PSZ femoral components may be indicated for high-demand patients and those with metal sensitivity.

  20. Pain syndrome in patient after hip replacement with a dual-modular femoral component (case report

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2014-01-01

    Full Text Available Total hip replacements with dualmodular femoral components (stemneck interface allow optimization of hip joint biomechanics via selective restoration of femoral anteversion, offset, and limb length theoretically improving muscle function and stability. Potential disadvantages are the additional stemneck interface and the possible generation of metal ions and debris by fretting and crevice corrosion. The authors reported a case of patient with dualmodular stem presenting with pain and decreased function. Earlyonset adverse inflammatory tissue reactions developed as a result of corrosion at the stemneck interface of a dualmodular implant, requiring subsequent revision of wellfixed components with an extended trochanteric osteotomy. Additional examinations excluded infection. We consider that patients with a modular stem and neck junction and presenting with pain should be suspected on corrosion at the stemneck interface and adverse inflammatory tissue reaction after infection exclusion.

  1. Analysis of {sup 18} F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Cremerius, U.; Niethard, F.U. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Klinik fuer Nuklearmedizin; Mumme, T.; Reinartz, P.; Wirtz, D. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Orthopaedische Klinik; Buell, U.

    2003-12-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [German] Ziel: Identifikation von Befundmustern in der Positronenemissionstomographie (PET) mit {sup 18}F

  2. Survivorship and Complications of Revision Total Hip Arthroplasty with a Mid-Modular Femoral Stem.

    Science.gov (United States)

    Riesgo, Aldo M; Hochfelder, Jason P; Adler, Edward M; Slover, James D; Specht, Lawrence M; Iorio, Richard

    2015-12-01

    We retrospectively reviewed 161 revision THAs with diaphyseal fitting, mid-modular femoral components performed by ten surgeons at two academic medical centers. The average follow-up was 6.1 years. At final follow-up, 4 patients required re-revision for failure of the femoral component; 3 (2%) for aseptic loosening and 1 for mechanical failure of stem in setting of periprosthetic fracture. There were a total of 24 (14.9%) revisions for any reason, with the most common reason being septic failure (10 of 24). To our knowledge, this is the largest reported series of mid-term survivorship and complications of revision THA with mid-modular femoral components. Our results show that these stems have a low rate of aseptic loosening, subsidence, and mechanical failure.

  3. Tissue response to the components of a hydroxyapatite-coated composite femoral implant.

    Science.gov (United States)

    Hacking, S A; Pauyo, T; Lim, L; Legoux, J G; Bureau, M N

    2010-09-01

    Bone loss around femoral implants used for THA is a persistent clinical concern. It may be caused by stress shielding, generally attributed to a mismatch in stiffness between the implants and host bone. In this regard, a fatigue resistant, carbon fiber (CF) composite femoral implant with bone-matching stiffness has been developed. This study evaluated the tissue response to the three material components of this implant in normal and textured (blasted with 24 grit alumina) surfaces: the hydroxyapatite (HA) coating, the CF composite and the intermediate crystalline HA particulate composite layer to bond to the HA coating (blended). Sprague-Dawley rats underwent bilateral femoral implantation each receiving two rod-like implants. Bone apposition to the HA (37%) and textured Ti (41%) implants was not significantly different. Bone apposition to the untextured CF (14%) and blended (19%) implants and polished Ti (8%) implants was significantly lower. Bone apposition to the textured CF (9%) and blended (11%) implants was lower (but not statistically from the as received or untextured counterparts). Nearly all sections from femurs containing CF implants presented CF debris. There was no evidence of localized bone loss or any strong immune response associated with any of the implant materials. All materials were well tolerated with minimal inflammation despite the presence of particulate debris. The high degree of bone apposition to the HA-coated composite implants and the lack of short-term inflammation and adverse tissue response to the three material implant component support continued evaluation of this composite technology for use in THA.

  4. The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty.

    Science.gov (United States)

    Merican, A M; Ghosh, K M; Iranpour, F; Deehan, D J; Amis, Andrew A

    2011-09-01

    Complications after total knee arthroplasty (TKA) often involve the patellofemoral joint, and problems with patellar maltracking or lateral instability have sometimes been addressed by external rotation of the femoral component. This work sought to measure the changes of knee kinematics caused by TKA and then to optimise the restoration of both the patellofemoral and tibiofemoral joint kinematics, by variation of femoral component internal-external rotation. The kinematics of the patella and tibia were measured in eight cadaveric knees during active extension motion. This was repeated with the knee intact, with a Genesis II TKA in the standard position (3° of external rotation) and with the femoral component at ±5° rotation from there. Both patellar and tibial motions were significantly different from normal with the standard TKA rotation, with 3° tibial abduction at 90° flexion and reversal of the screw-home from 5° external rotation to 6° internal rotation. The patella was shifted medially 6 mm in flexion and tilted 7° more laterally near extension. Femoral rotation to address one abnormality caused increased abnormality in other degrees of freedom. Internal and then external rotation of 5° caused tibial abduction and then adduction of 5° at 90° flexion. These femoral rotations also caused increased patellar lateral tilt of 4° with femoral external rotation and decreased tilt by 4° with internal rotation. Thus, correction of tibial abduction in flexion, by external rotation of the femoral component, worsened the patellar lateral tilt near extension. It was concluded that femoral rotation alone could not restore all aspects of both patellar and tibial kinematics to normal with this specific implant. The clinical relevance of this is that it appears to be inadvisable to reposition the femoral component, in an attempt to improve patellar tracking, if that repositioning may then cause abnormal tibiofemoral kinematics. Further, the pattern of patellar

  5. Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival: Review Article.

    Science.gov (United States)

    Civinini, Roberto; Matassi, Fabrizio; Carulli, Christian; Sirleo, Luigi; Lepri, Andrea Cozzi; Innocenti, Massimo

    2017-02-01

    Oxidized zirconium (OxZr) femoral component for total knee arthroplasty (TKA) have been introduced in an attempt to reduce polyethylene wear and secondary osteolysis and improve longevity of implants. We reviewed clinical studies in literature evaluating OxZr femoral component for TKA. The aim of this review was to evaluate the clinical outcome and survival rate of TKA with an OxZr femoral component. A review of the existing literature was undertaken to collect data on the OxZr femoral component in order to provide a better understanding of its performance. Of 34 studies published in the literature, 8 met the eligibility criteria and were included in the final analysis. Findings indicated that the mean Knee Society knee score improved in all series from preoperative to postoperative evaluation. The postoperative Knee Society knee score reported range from 84 to 95 and mean postoperative Knee Society functional score range from 74 to 90. The revision rate with this implant is low with up to 12.6 years of follow-up, with three revisions in total. The survival rate ranged from 100-98.7% at 5-7 years to 97.8% at 10 years. Excellent clinical outcome and high survival rate has been demonstrated for OxZr femoral component in TKA. No adverse reaction has been described for this new material.

  6. Clinical and radiographic evaluation of long-stem femoral components following revision total hip arthroplasty.

    Science.gov (United States)

    Meding, J B; Ritter, M A; Keating, E M; Faris, P M

    1994-08-01

    Fifty-four consecutive, long-stem revision hip arthroplasties were performed in 53 patients. In order to evaluate periprosthetic femoral changes, all cases utilizing cement, requiring bone-grafts for prosthetic stability, or with a follow-up period of less than 2 years were omitted. Thus, 32 long-stem revision hip arthroplasties in 32 patients were reviewed. Twenty-three Porous Coated Anatomic (Howmedica, Rutherford, NJ) and nine Bi-Metric (Biomet, Warsaw, IN) stems were implanted, with an average follow-up period of 3.6 years (range, 2-6 years). Prosthetic canal fill averaged 94% proximally and 80% distally. Intraoperative complications included three femoral shaft fractures. Harris hip scores averaged 47.8 points, before surgery and 87.6 points at the final follow-up evaluation, with 81% of patients the pain-free. Only three cases of subsidence and one case of osteolysis were noted. By 1 year, proximal osteopenia (off-load) (P = .005), bony condensation about the porous surface (spot weld) (P = .01), and pedestal formation (P = .004) were observed. The presence of distal cortical hypertrophy, (P = .02) spot weld (P = .001), and pedestal formation (P = .05) correlated significantly with off-load. Pedestal formation and distal cortical hypertrophy were commonly found together (P = .001). Despite significant periprosthetic remodeling, adequate fixation and satisfactory early clinical scores were achieved in this setting. Contrary to similar reviews using extensive bone-grafts, acceptable pain-free clinical results were obtained with these components.

  7. Effect of femoral component design on patellofemoral crepitance and patella clunk syndrome after posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Frye, Benjamin M; Floyd, Mark W; Pham, Dahn C; Feldman, John J; Hamlin, Brian R

    2012-06-01

    The purpose of this study was to determine if recent changes to the femoral component of a particular posterior-stabilized total knee prosthesis would affect the incidence of postoperative patellofemoral crepitance and patella clunk syndrome. One hundred eight total knee arthroplasties were performed with the conventional design; 136 were performed after the femoral component was changed. Complications were compared between the groups with an average follow-up of 17.7 months and 12.4 months, respectively. Thirteen knees with the conventional design (12%) were found to have patellofemoral complications; no complications were noted with the new design (P < .0001). Femoral components with a deep trochlear groove and smooth transition of the intercondylar box appear to better accommodate any peripatellar fibrous nodule that may form after total knee arthroplasty.

  8. [Effect of rotation of the femoral and tibial components on patellofemoral malalignment in knee arthroplasty].

    Science.gov (United States)

    Kienapfel, H; Springorum, H-P; Ziegler, A; Klose, K-J; Georg, C; Griss, P

    2003-04-01

    Patellofemoral complications are among the most common causes for revision surgery in total knee arthroplasty. So far no quantitative assessment has been made of the femoral and tibial malalignment or the positioning of the patellar component and the type of patellofemoral complication or failure. In particular, no comparative studies are available that include patients with and without patellofemoral failure in respect to the above-mentioned parameters when implant material, implant design, and fixation technique were identical. Between 1985 and 1992, 171 MG I total knee arthroplasties were performed. Since 1999, 20% of all the implanted MG I knee arthroplasties (all with metal-backed patellar component) had to be revised. Of those 34 patients, 18 were pair matched with 18 control patients based on the criteria of sex, body mass index, and age. The only difference in the control group was that they did not suffer any malfunction of the patellofemoral mechanism. To assess the patella component localization, conventional AP radiographs, patellar merchant view radiographs in 30 degrees, and CT scans were performed. This study has demonstrated a significant difference for the thickness of the patellar component and a trend regarding the rotational malalignment of the tibial component. Potential causes for the malrotation and guidelines to prevent rotational malalignment are discussed.

  9. Multicriteria Decision Analysis in Improving Quality of Design in Femoral Component of Knee Prostheses: Influence of Interface Geometry and Material

    Directory of Open Access Journals (Sweden)

    Ali Jahan

    2015-01-01

    Full Text Available Knee prostheses as medical products require careful application of quality and design tool to ensure the best performance. Therefore, quality function deployment (QFD was proposed as a quality tool to systematically integrate consumer’s expectation to perceived needs by medical and design team and to explicitly address the translation of customer needs into engineering characteristics. In this study, full factorial design of experiment (DOE method was accompanied by finite element analysis (FEA to evaluate the effect of inner contours of femoral component on mechanical stability of the implant and biomechanical stresses within the implant components and adjacent bone areas with preservation of the outer contours for standard Co-Cr alloy and a promising functionally graded material (FGM. The ANOVA revealed that the inner shape of femoral component influenced the performance measures in which the angle between the distal and anterior cuts and the angle between the distal and posterior cuts were greatly influential. In the final ranking of alternatives, using multicriteria decision analysis (MCDA, the designs with FGM was ranked first over the Co-Cr femoral component, but the original design with Co-Cr material was not the best choice femoral component, among the top ranked design with the same material.

  10. Orientation and depth estimation for femoral components using image sensor, magnetometer and inertial sensors in THR surgeries.

    Science.gov (United States)

    Jiyang Gao; Shaojie Su; Hong Chen; Zhihua Wang

    2015-08-01

    Malposition of the acetabular and femoral component has long been recognized as an important cause of dislocation after total hip replacement (THR) surgeries. In order to help surgeons improve the positioning accuracy of the components, a visual-aided system for THR surgeries that could estimate orientation and depth of femoral component is proposed. The sensors are fixed inside the femoral prosthesis trial and checkerboard patterns are printed on the internal surface of the acetabular prosthesis trial. An extended Kalman filter is designed to fuse the data from inertial sensors and the magnetometer orientation estimation. A novel image processing algorithm for depth estimation is developed. The algorithms have been evaluated under the simulation with rotation quaternion and translation vector and the experimental results shows that the root mean square error (RMSE) of the orientation estimation is less then 0.05 degree and the RMSE for depth estimation is 1mm. Finally, the femoral head is displayed in 3D graphics in real time to help surgeons with the component positioning.

  11. Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty : A study in 10 cadaver femora

    NARCIS (Netherlands)

    Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W.

    2007-01-01

    Use of an intramedullary rod is advised for the alignment of the femoral component of an Oxford phase-III prosthesis. There are users moving toward extramedullary alignment, which is merely an indicator of frustration with accuracy of intramedullary alignment. The results of our study with 10 cadave

  12. Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

    Science.gov (United States)

    Lin, Shih-Jie; Lee, Chien-Ying; Huang, Kuo-Chin; Peng, Kuo-Ti; Huang, Tsan-Wen; Lee, Mel S; Hsu, Robert Wen-Wei; Shen, Wun-Jer

    2015-09-02

    Accurate femoral rotational alignment is of vital importance for successful total knee arthroplasty (TKA). The value of computer-assisted surgery TKA (CAS-TKA) in increasing the accuracy of femoral rotational alignment remains controversial. We hypothesize that outcomes are related to the severity of preoperative varus and valgus deformity and that CAS-TKA may be beneficial under certain circumstances. Between January 2007 and December 2013, patients with osteoarthritis and varus angulation in the mechanical axis (MA) ≥ 15° and valgus angulation in the MA ≥ 10° (based on hip-to-ankle standing radiography) who underwent TKA were divided into four groups. CAS-TKA and conventional TKA outcomes were compared in patients who had preoperative advanced genu varum and advanced genu valgum deformities. The accuracy of component alignment and postoperative limb alignment was determined using radiographic parameters and computed tomography (CT). One hundred and eight patients (144 knees) were included in the analysis. For patients with preoperative advanced genu varum deformity, a significant difference was detected in the sagittal femoral angle (p genu valgum deformity, a significant difference was found in the sagittal femoral angle (p = 0.034). The femoral rotational angle was significantly closer to the proper position in the CAS-TKA group (p genu valgum deformity (p = 0.011). Our data demonstrate that CAS-TKA is beneficial in obtaining proper femoral rotational alignment in patients with advanced genu valgum deformity (preoperative MA ≥ 10° valgus). In patients with advanced genu varum deformity (preoperative MA ≥ 15° varus), CAS-TKA did not improve the femoral rotational alignment.

  13. Evaluation of anterior knee pain in a PS total knee arthroplasty: the role of patella-friendly femoral component and patellar size.

    Science.gov (United States)

    Atzori, F; Sabatini, L; Deledda, D; Schirò, M; Lo Baido, R; Baido, R L; Massè, A

    2015-04-01

    Total knee arthroplasty gives excellent objective results. Nevertheless, the subjective findings do not match the normal knee perception: Often, it depends on patellar pain onset. In this study, we analyzed clinical and radiological items that can affect resurfaced patellar tracking, and role of a patella-friendly femoral component and patellar size on patellar pain onset. Thirty consecutive patients were implanted using the same-cemented posterior-stabilized TKA associated with patella resurfacing. Fifteen patients were implanted using a classical femoral component, while another 15 patients were implanted using a patella-friendly femoral component. The statistical analysis was set to detect a significant difference (p patella-friendly femoral model) reached a higher percentage of 100 points in the clinical and functional KSS, but there was no statistical difference. Also, no statistical differences for Burnett Questionnaire results were recorded. We had one case of patellar clunk syndrome in the standard femoral component group and one poor result in the second group. Postoperative radiographic measurements evidenced no statistical differences in both groups. In group 1 (classical femoral component), better significant result (p patella-friendly" femoral components. With the particular type of implant design utilized in this study, when the classical femoral component is used, bigger patellar implant sizes (38 and 41 mm) showed superior clinical outcome.

  14. Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro

    NARCIS (Netherlands)

    C.L. de Korte (Chris); G. Pasterkamp (Gerard); H.A. Woutman; N. Bom (Klaas); A.F.W. van der Steen (Ton)

    2000-01-01

    textabstractBACKGROUND: The composition of plaque is a major determinant of coronary-related clinical syndromes. Intravascular ultrasound (IVUS) elastography has proven to be a technique capable of reflecting the mechanical properties of phantom material and the femoral arterial

  15. Prevalence and clinical significance of chondromalacia isolated to the anterior margin of the lateral femoral condyle as a component of patellofemoral disease: observations at MR imaging.

    LENUS (Irish Health Repository)

    Chan, V O

    2013-08-01

    To determine the prevalence of chondromalacia isolated to the anterior margin of the lateral femoral condyle as a component of patellofemoral disease in patients with anterior knee pain and to correlate it with patient demographics, patellar shape, and patellofemoral alignment.

  16. 非骨水泥股骨柄假体的中期疗效分析%Medium-term therapeutic evaluation of an uncemented femoral component

    Institute of Scientific and Technical Information of China (English)

    甄建国; 张卫国

    2011-01-01

    Objective :To study the clinical and radiographic results of tatal hip arthroplasty (THA) with an uncemented femoral component after 6 to 10 years follow-up, and to investigate factors effecting their efficacy. Methods: From January 2000 to December 2003,58 patients were treated with primary total hip arthroplasty. Among the patients, 27 patients were male and 31 patients were female ,ranging in age from 25 to 73 years ,with an average of 56 years. The 58 patients were clinically and radiographically followed up including before operation, postoperative 1.5,3,6 and 12 months, and then once a year. Therapeutic evaluation was measured by using Harris scoring system. The incidence of osteolysis around the components in different Gruen zones was radiologically determined. The data were analyzed by SPSS 16.0 software. Results:All the patients were followed up,and the duration ranged from 6 to 10 years,with a mean of 8.2 years. The Harris hip score of the patients improved from preoperative mean of(54.0±7.8 )to (88.3±6.1) at the latest follow-up. There were 32 patients with an excellent result, 22 good, 3 fair and 1 poor. Radiological analysis showed that 48 patients had stable bone in growth, 10 patients got stable fibrous in growth and nobody showed unstable fixation with aseptic loosening. Subsidence (1 to 3 mm) was observed in 4 patients. Osteolysis of the femoral cortex was seen in 4 patients without progressive development, and the latest follow-up radiographs showed a significantly greater incidence of osteolysis in Gruen zone Ⅰ , Ⅵ, Ⅶcompared with others (P=0.031 ). All the patients with low Harris score had received prostheses which were undersized in the intramedullary canal, and these differences were statistically significant. Conclusion:The uncemented femoral component has good medium-term clinical follow-up results because of high stability and no aseptic loosening.%目的:通过对一组行人工全髋关节置换术(THA)随访6~10年的病例

  17. Study of the clinical application of salmon calcitonin in the prevention of aseptic loosening of the prosthesis after artificial femoral head replacement%鲑鱼降钙素在预防人工股骨头置换术后假体无菌性松动的临床应用研究

    Institute of Scientific and Technical Information of China (English)

    陈述祥; 刘彦; 区文欢; 康乐; 丁林坚; 司徒坚; 廖志鹏; 陈丽君

    2014-01-01

    Objective To investigate the clinical efficacy of salmon calcitonin in the prevention of aseptic loosening of the prosthesis after artificial femoral head replacement.Methods One hundred and forty-six patients who received artificial femoral head replacement from January 2010 to January 2011 in the Department of Orthopedics and Traumatology of Wuyi Hospital of Traditional Chinese Medicine were followed up.They were randomly divided into treatment group and control group, with 73 cases in each group.Patients in control group received oral calcium tablets daily (Caltrate D, containing 600mg calcium and 125u vitamin D).Patients in the treatment group received subcutaneous injection of calcitonin salmon (Miacalcic 50U) daily besides calcium tablets.The treatment lasted for 6 months.Bone mineral density ( BMD ) around the prosthesis ( ROI ) in both groups were examined before and 4-, 8-, 12-, and 24-week after the operation.Serum bone metabolic markers osteocalcin ( BGP) and type I collagen peptide ( C end of heterogeneous beta,β-CTX) were deterimined in patients of both groups before and 4-, 12-, and 24-week after the operation.BMD and bone metabolic markers before and after the operation were comparied and analyzed. Results After 24-week of operation, BMD of ROI in the treatment group increased nearly 5%, while BMD of ROI in the control group decreased 6%.The difference between the two groups was significant ( P005).However, these indexes were significantly different comparing to those in the control group (P <0.05 or P <0.01). Conclusion The treatment of salmon calcitonin ( Miacalcic) combined with basic therapy can significantly improve bone mass around the prosthesis, which is one of the effective methods for prevention of aseptic loosening.%目的:探讨鲑鱼降钙素在预防人工股骨头置换术后假体无菌性松动的临床应用效果。方法通过随访江门市五邑中医院骨伤科二区2010年1月至2011年1月146例人工股骨头

  18. Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

    Science.gov (United States)

    Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi

    2017-02-14

    This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.

  19. Isolated acetabular revision with femoral stem retention after bipolar hip arthroplasty.

    Science.gov (United States)

    Kaku, Nobuhiro; Tabata, Tomonori; Tagomori, Hiroaki; Tsumura, Hiroshi

    2017-03-01

    In bipolar hemiarthroplasty, migration of the outer cup component into the acetabular cup, with evidence of severe osteolysis in the acetabulum, commonly occurs without loosening of the femoral component. The merits of retaining the stable femoral component in these cases have been debated. Our study aimed to determine whether revision of the acetabular component in isolation could be successfully performed. The data of 54 patients (61 hips), 44 women, and 10 men, aged 67.7 (range 47-86) years at the time of the index revision, were analyzed. The average time from primary operation to revision surgery was 14.9 (range 1.0-27.0) years, with an average follow-up time after revision of 5.2 (range, 1.0-18.7) years. Indications for acetabular revision included migration of the outer cup component (N = 55), disassembly of the bipolar cup (N = 4), and recurrent dislocation (N = 2). Fixation of the femoral stem was cementless in 49 hips and cemented in 12. Bone grafting for osteolysis of the proximal femur around the stem was performed in six hips. An acetabular reinforcement ring with a cemented cup was used in 31 hips, with cementless cup fixation in 29 hips, and cemented cup in one case. On average, the Harris hip score improved from 57.0 ± 21.6 to 87.4 ± 6.40 points after revision. Two cases of femoral periprosthetic fracture were treated with osteosynthesis 3 year post-revision. There was no evidence of loosening of the femoral stem or subsidence, with a non-progressive radiolucent line acetabular revision can be reliably performed in cases of failed bipolar hemiarthroplasty with a well-fixed femoral component.

  20. Fracture of the femoral component after a lightning strike injury: A case report.

    Science.gov (United States)

    Lizano-Díez, Xavier; Alentorn-Geli, Eduard; León-García, Alfonso; Marqués-López, Fernando

    2017-01-01

    A fracture of the stem in a total hip arthroplasty (THA) is an uncommon complication. We report a case of femoral stem fracture in a 55-year-old male patient after a lightning strike. A revision was conducted using a Wagner osteotomy and a revision prosthesis. Dall-Milles cerclages were used to close the osteotomy. The postoperative evolution was satisfactory, with an immediate partial weight bearing, consolidation of the osteotomy after three months and return to daily activity without pain. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  1. Potent effect of zinc acexamate on bone components in the femoral-metaphyseal tissues of elderly female rats.

    Science.gov (United States)

    Yamaguchi, M; Gao, Y H

    1998-03-01

    1. The effect of zinc compounds on bone components in the femoral-metaphyseal tissues from elderly female rats (50 weeks old) was investigated in vitro. Bone tissues were cultured for 24 hr in Dulbecco's modified Eagle medium containing either vehicle or zinc compounds (10[-7] to 10[-5] M). 2. Zinc content, alkaline phosphatase activity, deoxyribonucleic acid (DNA) and calcium contents in the metaphyseal tissues were significantly increased by the presence of zinc sulfate (10[-6] and 10[-5] M), beta-alanyl-L-histidinato zinc (AHZ; 10[-6] and 10[-5] M) and zinc acexamate (10[-7] to 10[-5] M). At 10[-5] M, the effect of zinc acexamate on the increase of bone components was more potent than that of zinc sulfate or AHZ. 3. The effect of zinc acexamate (10[-5] M) on the increase of alkaline phosphatase activity in the metaphyseal tissues was remarkable as compared with that of insulin (10[-8] M), estrogen (10[-9] M), insulin-like growth factor-I (10[-8] M), transforming growth factor-beta (10[-10] M), sodium fluoride (10[-3] M), dexamethasone (10[-7] M) and vitamin K2 (menaquinone-4; 10[-5] M) with an effective concentration. 4. The stimulatory effect of zinc acexamate (10[-5] M) on alkaline phosphatase activity and calcium content in the metaphyseal tissues was completely blocked by the presence of dipicolinate (10[-3] M), a chelator of zinc ion, and of cycloheximide (10[-6] M), an inhibitor of protein synthesis. 5. The present study demonstrates that zinc acexamate has a potent anabolic effect on bone components in the femoral-metaphyseal tissues from female elderly rats in vitro. The effect of zinc acexamate may be based in part on protein synthesis related to zinc ion in bone cells.

  2. [EFFECTIVENESS OF ANATOMIC FEMORAL COMPONENT PROSTHESIS FOR SEVERE DEVELOPMENTAL DYSPLASIA OF THE HIP IN TOTAL HIP ARTHROPLASTY].

    Science.gov (United States)

    An, Xiao; Dong, Jiyuan; Gong, Ke; Zhang, Qi; Li, Xiang; Song, Wei

    2015-04-01

    To evaluate the effectiveness of anatomic femoral component prosthesis for severe development dysplasia of the hip (DDH) in total hip arthroplasty (THA). Between September 2009 and September 2013, 48 patients (51 hips) with severe DDH underwent THA with cementless anatomic femoral component prosthesis. There were 5 males (5 hips) and 43 females (46 hips) with an average age of 51 years (range, 28-67 years). The left hip was involved in 25 cases, the right hip in 20 cases, and bilateral hips in 3 cases. There were 39 cases (44 hips) of Crowe type III and 9 cases (7 hips) of Crowe type IV. The visual analogue scale (VAS) score was 5.72 +/- 1.84, and Harris score was 41.66 +/- 4.87 at preoperation. All patients had leg discrepancy with a length difference of (4.31 +/- 0.84) cm. The duration of surgery was 59-110 minutes (mean, 78.6 minutes), and the hospitalization days were 6-20 days (mean, 12.3 days). All patients obtained primary healing of incision without wound related complications of swelling, effusion, and infection. Two patients were found to have intramuscular venous thrombosis. All patients were followed up 10-54 months (mean, 29 months). Limp was observed at the early stage after operation in 9 patients and disappeared after 1 year, the other patients had normal gait. The VAS score 1.46?0.47, Harris score 88.66 +/- 3.48, and the leg length difference (1.15 +/- 0.33) cm at last follow-up all showed significant differences when compared with the preoperative values (Phip joint function and limb discrepancy. Short-term effectiveness was satisfactory, but the long-term effectiveness should still be observed in future.

  3. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty; Valutazione con Tomografia Computerizzata della rotazione delle componenti femorale e tibiale nell'artroprotesi totale del ginocchio

    Energy Technology Data Exchange (ETDEWEB)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). Servizio di Diagnostica per Immagini; Trentani, F.; Trentani, P.; Tigani, D. [Istituto Ortopedico Rizzoli, Bologna (Italy). VII Div.; Nigrosoli, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). IV Div.

    2000-06-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteria were prosthesis loosening and severe (equal or superior to 7 degrees) varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  4. Topography of the femoral nerve in relation to components of the iliopsoas muscle in human fetuses.

    Science.gov (United States)

    Jakubowicz, M

    1991-01-01

    Studies were performed on 60 human fetuses of both sexes of 35 to 365 mm C.-R. length (9-40 weeks). The psoas minor muscle was found in 25.8% of cases independently of sex and body side. In 6.45% of cases the muscle continued into psoas major muscle by short, weakly developed tendon. In 97.5% of studied fetuses junctions between tendons of psoas major and iliacus muscles was observed. In 2.5% of cases an independent, short tendon was found in the half of length of the iliacus muscle. In 7.5% of cases connection between the psoas major and iliacus muscles was found. In all cases femoral nerve originated from the lumbar plexus between two layers of the psoas major muscle and it ran in the groove between the psoas major and iliacus muscles towards the muscular lacuna. In 5.0% of cases the nerve divided into crura. In 2.5% of cases the crura embraced anteriorly and posteriorly bundles of the psoas major muscle as well as in 2.5% of cases bundles of the iliacus muscle.

  5. Loosening Psychometric Constraints on Educational Assessments

    Science.gov (United States)

    Kane, Michael T.

    2017-01-01

    In response to an argument by Baird, Andrich, Hopfenbeck and Stobart (2017), Michael Kane states that there needs to be a better fit between educational assessment and learning theory. In line with this goal, Kane will examine how psychometric constraints might be loosened by relaxing some psychometric "rules" in some assessment…

  6. The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures.

    Science.gov (United States)

    O'Shea, K; Quinlan, J F; Kutty, S; Mulcahy, D; Brady, O H

    2005-12-01

    We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. A retrospective clinical and radiographic assessment of 22 patients with a mean follow-up of 33.7 months was performed. The mean time from the index procedure to fracture was 10.8 years. There were 17 patients with a satisfactory result. Complications in four patients included subsidence in two, deep sepsis in one, and delayed union in one. Concomitant acetabular revision was required in 19 patients. Uncemented extensively porous-coated femoral stems incorporate distally allowing stable fixation. We found good early survival rates and a low incidence of nonunion using this implant.

  7. A randomised controlled trial of cemented and cementless femoral components for metal-on-metal hip resurfacing: a bone mineral density study.

    Science.gov (United States)

    Tice, A; Kim, P; Dinh, L; Ryu, J J; Beaulé, P E

    2015-12-01

    The primary purpose of this study of metal-on-metal (MoM) hip resurfacing was to compare the effect of using a cementless or cemented femoral component on the subsequent bone mineral density (BMD) of the femoral neck. This was a single-centre, prospective, double-blinded control trial which randomised 120 patients (105 men and 15 women) with a mean age of 49.4 years (21 to 68) to receive either a cemented or cementless femoral component. Follow-up was to two years. Outcome measures included total and six-point region-of-interest BMD of the femoral neck, radiological measurements of acetabular inclination, neck-shaft and stem-shaft angles, and functional outcome scores including the Harris hip score, the Western Ontario and McMaster Universities Osteoarthritis Index and the University of California at Los Angeles activity scale. In total, 17 patients were lost to follow-up leaving 103 patients at two years. There were no revisions in the cementless group and three revisions (5%) in the cemented group (two because of hip pain and one for pseudotumour). The total BMD was significantly higher in the cementless group at six months (p < 0.001) and one year (p = 0.01) than in the cemented group, although there was a loss of statistical significance in the difference at two years (p = 0.155). All patient outcomes improved significantly: there were no significant differences between the two groups. The results show better preservation of femoral neck BMD with a cementless femoral component after two years of follow-up. Further investigation is needed to establish whether this translates into improved survivorship.

  8. Risk factors for post-operative periprosthetic fractures following primary total hip arthroplasty with a proximally coated double-tapered cementless femoral component

    DEFF Research Database (Denmark)

    Gromov, K; Bersang, A; Nielsen, C S

    2017-01-01

    periprosthetic fractures (3.0%) were identified during the follow-up and median time until fracture was 16 days, (interquartile range 10 to 31.5). Patients with femoral Dorr type C had a 5.2 times increased risk of post-operative periprosthetic fracture compared with type B, while female patients had a near...... significant two times increased risk over time for post-operative fracture. CONCLUSION: Dorr type C is an independent risk factor for early periprosthetic fracture, following THA using a double tapered cementless stem such as the Bi-Metric. Surgeons should take bone morphology into consideration when planning......AIMS: The aim of this study was to identify patient- and surgery-related risk factors for sustaining an early periprosthetic fracture following primary total hip arthroplasty (THA) performed using a double-tapered cementless femoral component (Bi-Metric femoral stem; Biomet Inc., Warsaw, Indiana...

  9. PEEK-OPTIMA(™) as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-11-01

    PEEK-OPTIMA(™) (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA(™) as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA(™) femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm(3)/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm(3)/million cycles and 2.44 ± 0.78 mm(3)/million cycle against cobalt chrome and PEEK-OPTIMA(™) implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm(3)/million cycles and 4.44 ± 2.35 mm(3)/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA(™) femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA(™) femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the

  10. Revision hip arthroplasty in patients with a previous total hip replacement for osteonecrosis of the femoral head.

    Science.gov (United States)

    Park, Youn-Soo; Moon, Young-Wan; Lee, Keun-Ho; Lim, Seung-Jae

    2014-12-01

    Patients with osteonecrosis of the femoral head are typically relatively young and active and often require high rates of revision after primary total hip arthroplasty. However, outcomes of revision hip arthroplasty in this patient population have rarely been reported in the literature. The authors conducted a retrospective review of 72 patients (75 hips) who underwent revision hip arthroplasty with a primary diagnosis of osteonecrosis of the femoral head. Mean age at index revision was 53.3 years (range, 34-76). Components of acetabular revision included a cementless porous-coated cup in 58 hips and an acetabular cage in 3 hips. Components of femoral revision included a fully grit-blasted tapered stem in 30 hips and a proximally porous-coated modular stem in 9 hips. Mean duration of follow-up was 7 years (range, 3-17). Mean Harris Hip Score improved from 49 points preoperatively to 90 points postoperatively. At final follow-up, 11 hips (14.7%) required reoperation because of aseptic loosening (6 hips), infection (2 hips), recurrent dislocation (1 hip), periprosthetic fracture (1 hip), and ceramic fracture (1 hip). Kaplan-Meier survivor-ship with an endpoint of re-revision for any reason was 81% and for mechanical failure was 87.5% for the cup and 100% for the stem at 10 years. Unlike the previous report, the authors' study showed a lower failure rate of the femoral stem after revision hip arthroplasty using modern cementless femoral components in patients with osteonecrosis of the femoral head. Aseptic cup loosening or osteolysis is the most common mechanism of failure at medium-term follow-up. Copyright 2014, SLACK Incorporated.

  11. Is there added risk in resurfacing a femoral head with cysts?

    Directory of Open Access Journals (Sweden)

    Liu Fei

    2011-10-01

    Full Text Available Abstract Background Femoral head cysts have been identified as a risk factor for early femoral failures after metal-on-metal hip resurfacing arthroplasty (HRA based on limited scientific data. However, we routinely performed HRA if less than 1/3 of the femoral head appeared destroyed by cysts on the preoperative radiograph. This study was undertaken to analyze whether there was an added risk of early femoral failures in HRA when femoral head cysts were present. Methods This retrospective case-control study included 939 MOM HRAs operated by a single surgeon with use of the posterior minimally invasive surgical (MIS approach between November 2005 and January 2009. Patients with all diagnoses except osteonecrosis were included. Among them, 117 HRAs had femoral head cysts ≥ 1 cm identified in surgery. All cysts were treated with bone grafting using acetabular reamings packed into the cavitary defect (instead of filling the cysts with cement. The control group, which had no cyst observed at the time of surgery, was randomly selected from our database using computer algorithms to match those cases in the study group for the parameters of surgical date, age, gender, body mass index, diagnosis, femoral fixation method, and the size of the femoral component. Results The minimum follow-up was 24 months for both groups. The early femoral failure rate in the study group was 3/117 (2.6% and 0/117 in the control group; there was no statistical difference between these two groups (P = 0.08. In the study group, there were two femoral neck fractures (revised: both occurred in patients having a cyst size of 1 cm3; and there was one femoral component loosening at 3-year follow up in a patient having a cyst size of 2 cm3. Conclusion Although the risk of early femoral failures among the group with cysts appeared higher than the group without cysts, we could not demonstrate a significant statistical difference between the two groups. It is possible that bone

  12. Circumferential proximal femoral allografts in revision hip arthroplasty: four to 20 years follow-up.

    Science.gov (United States)

    Roos, Bruno Dutra; Roos, Milton Valdomiro; Camisa, Antero

    2013-01-01

    The purpose of this study was to analyze the clinical and radiographic results of revision of loose total hip replacements, using proximal femoral allografts and a cemented implant. We retrospectively reviewed of 28 consecutive patients. Twenty patients were available for study. Each patient was scored using a modified Harris Hip Score. Radiographs were examined for endosteal and periosteal reabsorption, allograft-host union, trochanteric migration, component loosening and heterotrophic calcification. The mean pre-operative Harris hip Score was 34 points. At the latest follow-up, the meanscore was 80 points. Nineteen cases (95%) had combined femoral defects and one patient (5%) had a segmental defect, according to the AAOS classification. Allograft resorption was seen in eight (40%) hips. There were 18 cases (90%) of allograft union, one (5%) of partial union and one (5%) of nonunion. There was one case of trochanteric migration (more than 1 cm). All femoral components were radiographically stable. The reconstruction was considered successful in 18 patients (90%). The use of proximal femoral allografts in femoral revision of loose total hip replacements has high survival and satisfactory clinical results at an average period of eight years postoperatively.

  13. Current concepts in total femoral replacement.

    Science.gov (United States)

    Ramanathan, Deepak; Siqueira, Marcelo Bp; Klika, Alison K; Higuera, Carlos A; Barsoum, Wael K; Joyce, Michael J

    2015-12-18

    Total femoral replacement (TFR) is a salvage arthroplasty procedure used as an alternative to lower limb amputation. Since its initial description in the mid-20(th) century, this procedure has been used in a variety of oncologic and non-oncologic indications. The most compelling advantage of TFR is the achievement of immediate fixation which permits early mobilization. It is anticipated that TFR will be increasingly performed as the rate of revision arthroplasty rises worldwide. The existing literature is mainly composed of a rather heterogeneous mix of retrospective case series and a wide assortment of case reports. Numerous TFR prostheses are currently available and the surgeon must understand the unique implications of each implant design. Long-term functional outcomes are dependent on adherence to proper technique and an appropriate physical therapy program for postoperative rehabilitation. Revision TFR is mainly performed for periprosthetic infection and the severe femoral bone loss associated with aseptic revisions. Depending on the likelihood of attaining infection clearance, it may sometimes be advisable to proceed directly to hip disarticulation without attempting salvage of the TFR. Other reported complications of TFR include hip joint instability, limb length discrepancy, device failure, component loosening, patellar maltracking and delayed wound healing. Further research is needed to better characterize the long-term functional outcomes and complications associated with this complex procedure.

  14. Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions.

    Science.gov (United States)

    Osman, K; Panagiotidou, A P; Khan, M; Blunn, G; Haddad, F S

    2016-05-01

    There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice. Cite this article: Bone Joint J 2016;98-B:579-84.

  15. An investigation of the aseptic loosening of an AISI 316L stainless steel hip prosthesis.

    Science.gov (United States)

    Godec, Matjaz; Kocijan, Aleksandra; Dolinar, Drago; Mandrino, Djordje; Jenko, Monika; Antolic, Vane

    2010-08-01

    The total replacement of joints by the implantation of permanently indwelling prosthetic components has been one of the major successes of modern surgery in terms of relieving pain and correcting deformity. However, the aseptic loosening of a prosthetic-joint component is the most common reason for joint-revision surgery. Furthermore, it is thought that wear particles are one of the major contributors to the development and perpetuation of aseptic loosening. The aim of the present study was to identify the factors related to the aseptic loosening of an AISI 316L stainless steel total hip prosthesis. The stem was evaluated by x-ray photoelectron spectroscopy, with polished and rough regions being analyzed in order to establish the differences in the chemical compositions of both regions. Specific areas were examined using scanning electron microscopy with energy dispersive x-ray spectroscopy and light microscopy.

  16. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    Science.gov (United States)

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-04-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm(3) with the consequent median value for metal-on-metal taper loss being 1.75 mm(3). This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm(3). Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  17. Loosening Xyloglucan Accelerates the Enzymatic Degradation of Cellulose in Wood

    Institute of Scientific and Technical Information of China (English)

    Rumi Kaida; Tomomi Kaku; Kei'ichi Baba; Masafumi Oyadomari; Takashi Watanabe; Koji Nishida; Toshiji Kanaya; Ziv Shani; Oded Shoseyov; Takahisa Hayashi

    2009-01-01

    In order to create trees in which cellulose, the most abundant component in biomass, can be enzymatically hydrolyzed highly for the production of bioethanol, we examined the saccharification of xylem from several transgenic poplars, each overexpressing either xyloglucanase, cellulase, xylanase, or galactanase. The level of cellulose degradation achieved by a cellulase preparation was markedly greater in the xylem overexpressing xyloglucanase and much greater in the xylems overexpressing xylanase and cellulase than in the xylem of the wild-type plant. Although a high degree of degradation occurred in all xylems at all loci, the crystalline region of the cellulose microfibrUs was highly degraded in the xylem overexpressing xyloglucanase. Since the complex between microfibrils and xyloglucans could be one region that is particularly resistant to cellulose degradation, loosening xyloglucan could facilitate the enzymatic hydrolysis of cellulose in wood.

  18. Femoral bowing plane adaptation to femoral anteversion

    Directory of Open Access Journals (Sweden)

    Alp Akman

    2017-01-01

    Full Text Available Background: Femoral bowing plane (FBP is the unattended subject in the literature. More over the femoral shaft with its bowing is neglected in established anteversion determination methods. There is limited information about the relationship between FBP and anteversion. Thus we focused on this subject and hypothesized that there could be an adaptation of FBP to anteversion. Materials and Methods: FBP is determined on three-dimensional solid models derived from the left femoral computerized tomography data of 47 patients which were taken before for another reason and comparatively evaluated with anteversion. There were 20 women and 27 men. The mean age of patients was 56 years (range 21-84 years. Results: The anteversion values were found as the angle between a distal condylar axis (DCA and femoral neck anteversion axis (FNAA along an imaginary longitudinal femoral axis (LFA in the true cranio-caudal view. The FBP was determined as a plane that passes through the centre-points of three pre-determinated sections on the femoral shaft. The angles between DCA, FNAA and FBP were comparatively evaluated. The independent samples t-test was used for statistical analysis. At the end, it was found that FBP lies nearly perpendicular to the anteversion axis for the mean of our sample which is around 89° in females and 93° in males (range 78-102°. On the other hand, FBP does not lie close to the sagittal femoral plane (SFP; instead, there is an average 12.5° external rotation relative to the SFP. FBP is correlated well with anteversion in terms of FBP inclination from SFP and femoral torsion (i.e., angle between FBP and femoral neck anteversion axis (P0 < 0.001; r = 0.680 and r = −0.682, respectively. Combined correlation is perfect (R[2] = 1 as the FBP, SFP, and posterior femoral plane forms a triangle in the cranio-caudal view. Conclusions: We found that FBP adapts to anteversion. As FBP lies close to perpendicularity for the mean, femoral component

  19. Femoral bowing plane adaptation to femoral anteversion

    Science.gov (United States)

    Akman, Alp; Demirkan, Fahir; Sabir, Nuran; Oto, Murat; Yorukoglu, Cagdas; Kiter, Esat

    2017-01-01

    Background: Femoral bowing plane (FBP) is the unattended subject in the literature. More over the femoral shaft with its bowing is neglected in established anteversion determination methods. There is limited information about the relationship between FBP and anteversion. Thus we focused on this subject and hypothesized that there could be an adaptation of FBP to anteversion. Materials and Methods: FBP is determined on three-dimensional solid models derived from the left femoral computerized tomography data of 47 patients which were taken before for another reason and comparatively evaluated with anteversion. There were 20 women and 27 men. The mean age of patients was 56 years (range 21–84 years). Results: The anteversion values were found as the angle between a distal condylar axis (DCA) and femoral neck anteversion axis (FNAA) along an imaginary longitudinal femoral axis (LFA) in the true cranio-caudal view. The FBP was determined as a plane that passes through the centre-points of three pre-determinated sections on the femoral shaft. The angles between DCA, FNAA and FBP were comparatively evaluated. The independent samples t-test was used for statistical analysis. At the end, it was found that FBP lies nearly perpendicular to the anteversion axis for the mean of our sample which is around 89° in females and 93° in males (range 78–102°). On the other hand, FBP does not lie close to the sagittal femoral plane (SFP); instead, there is an average 12.5° external rotation relative to the SFP. FBP is correlated well with anteversion in terms of FBP inclination from SFP and femoral torsion (i.e., angle between FBP and femoral neck anteversion axis (P < 0.001; r = 0.680 and r = −0.682, respectively). Combined correlation is perfect (R2 = 1) as the FBP, SFP, and posterior femoral plane forms a triangle in the cranio-caudal view. Conclusions: We found that FBP adapts to anteversion. As FBP lies close to perpendicularity for the mean, femoral component positioning

  20. Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study.

    Science.gov (United States)

    Kang, Kyoung-Tak; Son, Juhyun; Kim, Ho-Joong; Baek, Changhyun; Kwon, Oh-Ryong; Koh, Yong-Gon

    2017-07-01

    The wear of ultrahigh-molecular weight polyethylene (UHMWPE) tibial inserts in total knee arthroplasty (TKA) remains a major limitation that hinders the longevity of clinically successful devices. Surface properties significantly affect the overall performance of TKA, and surface modification with mechanically and chemically stable materials is an effective method for overcoming the wear of TKA. However, wear tests are not cost-efficient or time-efficient; thus, the effects of geometric, loading, and alignment perturbations are often evaluated via parametric studies. Computational wear prediction using a finite element (FE) model followed by validation through comparison with experimental data is effective for assessing new prosthetic designs or surface change methods prior to functional testing and surgical implementation. The aim of this study was to evaluate the weight loss, wear depth, and kinematics for different surface properties, including nanostructured diamond (NSD), diamond-like carbon (DLC), titanium-nitride (TiN), and oxidized zirconium (OxZr) on femoral components in TKA using FE analysis under gait-cycle loading conditions. Weight loss and wear depth were lowest with OxZr followed by TiN, NSD, and DLC. However, the DLC femoral component did not show any improvement in wear rate compared to an uncoated cobalt-chromium (Co-Cr) femoral component. Not all surface changes applied in this study did lead to improvement in wear performance. However, this study demonstrates the potential of OxZr and TiN for reducing UHMWPE wear and offers new insights into the effects of wear on TKA.

  1. The association of lesion eccentricity with plaque morphology and components in the superficial femoral artery: a high-spatial-resolution, multi-contrast weighted CMR study

    Directory of Open Access Journals (Sweden)

    Zhao Xihai

    2010-07-01

    Full Text Available Abstract Background Atherosclerotic plaque morphology and components are predictors of subsequent cardiovascular events. However, associations of plaque eccentricity with plaque morphology and plaque composition are unclear. This study investigated associations of plaque eccentricity with plaque components and morphology in the proximal superficial femoral artery using cardiovascular magnetic resonance (CMR. Methods Twenty-eight subjects with an ankle-brachial index less than 1.00 were examined with 1.5T high-spatial-resolution, multi-contrast weighted CMR. One hundred and eighty diseased locations of the proximal superficial femoral artery (about 40 mm were analyzed. The eccentric lesion was defined as [(Maximum wall thickness- Minimum wall thickness/Maximum wall thickness] ≥ 0.5. The arterial morphology and plaque components were measured using semi-automatic image analysis software. Results One hundred and fifteen locations were identified as eccentric lesions and sixty-five as concentric lesions. The eccentric lesions had larger wall but similar lumen areas, larger mean and maximum wall thicknesses, and more calcification and lipid rich necrotic core, compared to concentric lesions. For lesions with the same lumen area, the degree of eccentricity was associated with an increased wall area. Eccentricity (dichotomous as eccentric or concentric was independently correlated with the prevalence of calcification (odds ratio 3.78, 95% CI 1.47-9.70 after adjustment for atherosclerotic risk factors and wall area. Conclusions Plaque eccentricity is associated with preserved lumen size and advanced plaque features such as larger plaque burden, more lipid content, and increased calcification in the superficial femoral artery.

  2. Does mismatch of the femoral component aspect ratio influence the range of knee flexion after posterior-stabilized total knee arthroplasty?

    Institute of Scientific and Technical Information of China (English)

    JIA Yu-tao; WANG Lei; ZHANG Yu; ZHAO Cong; SUN Zhen-hui; LIU Jun

    2012-01-01

    Objective: To study whether the range of knee flexion (ROF) is affected by geometrical mismatch of the femoral component and the resultant change in the posterior condylar offset (PCO) after high-flexion posterior-stabilized total knee arthroplasty (TKA).Methods:One hundred osteoarthritic patients (50 males and 50 females) underwent femoral osteotomy by the anterior referencing technique.The PCO for each patient was measured from lateral radiographs before,during and 2 years after TKA.The thickness of the joint cartilage was measured by magnetic resonance imaging before TKA and added onto the radiographic measurement.The relationship between changes in the PCO and improvements in the ROF before,during and 2 years after TKA were statistically analyzed.Results: Compared with the preoperative value,the PCO was reduced by (3.45±3.28) mm after TKA,with a significantly larger reduction observed in female patients than male patients (P<0.05).When examining the subject population as a whole,there was a significant positive correlation between PCO and ROF improvement during TKA (P< 0.05),but this improvement was not maintained 2 years after TKA (P>0.05).However,when male and female patients were analyzed separately,there was a significant positive correlation between PCO change and ROF improvement for both sexes at both time points (all P<0.05).Conclusions: Restoration of PCO plays an important role in the optimization of knee flexion even after posteriorstabilized TKA.Femoral components based on Caucasian anatomic characteristics could not match the native anatomy of distal femurs in Chinese population especially female Chinese.Rotated resection of distal femur with anterior referencing technique usually leads to a decreased PCO and therefore reduces maximal obtainable flexion.

  3. Unique relationship between osteophyte and femoral-tibia component size mismatch in determining polyethylene wear in primary total knee arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Ramappa Manjunath

    2009-02-01

    Full Text Available Abstract Introduction Knee pain is a complex problem that can occur after total knee arthroplasty. One cause of knee pain may be due to a retained osteophyte, but it is not clear if the retained osteophyte is sufficient explanation of the pain, as not all patients with retained osteophytes are symptomatic. In fact, the literature shows that excised osteophytes can also recur over a period of time, without any symptoms. Therefore a retained osteophyte alone is probably not sufficient to cause symptoms. Case presentation We present a case of intermittent medial knee pain occurring post-primary total knee arthroplasty, in a patient who underwent several investigations over a period of 5 years. Radiographs showed an osteophyte in the postero-medial femur along with slight tibial component overhang which was normal for that knee implant design. The symptoms eventually settled with excision of only the osteophyte, without altering the tibial component. Conclusion A retained osteophyte alone, or tibial component overhang alone, did not seem to cause significant symptoms in our patient whose symptoms completely settled with excision of the osteophyte alone, without changing the tibial component. Therefore, it seems that the combination of retained osteophyte and tibial component overhang (tibia-femoral component size mismatch are detrimental and therefore best avoided. This report also emphasises the importance of meticulous osteophyte excision and avoiding tibial component overhang during knee arthroplasty.

  4. A New Computed Tomography-Based Radiographic Method to Detect Early Loosening of Total Wrist Implants

    Energy Technology Data Exchange (ETDEWEB)

    Olivecrona, H.; Noz, M.E.; Maguire, G.Q. Jr; Zeleznik, M.P.; Sollerman, C.; Olivecrona, L. [Dept. of Hand Surgery, Soedersjukhuset, Stockholm (Sweden)

    2007-11-15

    Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.

  5. Trunnion Corrosion and Early Failure in Monolithic Metal-on-Polyethylene TMZF Femoral Components: A Case Series

    Directory of Open Access Journals (Sweden)

    Peter Walker

    2016-09-01

    Full Text Available We describe four patients who were treated with primary total hip arthroplasty (THA at two tertiary academic Australian teaching hospitals that experienced premature failure of head-neck trunnions through dissociation of the head-neck taper junction. This retrospective case series have similar clinical presentations and macroscopic pathology with severe head-neck taper junction loss of material, corrosion and early catastrophic failure. It is proposed that the accelerated wear is related to use of varus offset neck in a proprietary beta titanium alloy (Ti-12Mo-6Zr-2Fe  or TMZFÒ Stryker Osteonics, Mahwah NJ, USA TMZF femoral stem, longer head-neck combination in a relatively active, older, male patient population. In this limited case series presentation was on average 80 months (range 53-92 following index procedure. In three of the four patients, a prodromal period of groin or buttock pain was reported for between 1 week and 2 months prior to acute presentation. Significant metallosis and local tissue damage including gluteal muscle insufficiency was evident. Each stem revised was well fixed. An extended trochanteric osteotomy was required in two of the four cases for stem extraction. We recommend caution and further evaluation on the relationship between TMZF metal alloy and its longevity in higher demand patients with high neck offset, varus stem geometry and large CoCr bearing heads.

  6. Risk factor analysis for early femoral failure in metal-on-metal hip resurfacing arthroplasty: the effect of bone density and body mass index

    Directory of Open Access Journals (Sweden)

    Gross Thomas P

    2012-01-01

    Full Text Available Abstract Background The importance of appropriately selecting patients based on factors such as bone mineral density, body mass index, age, gender, and femoral component size has been demonstrated in many studies as an aid in decreasing the rate of revisions and improving the outcomes for patients after hip resurfacing arthroplasty (HRA; however, there are few published studies quantitatively specifying the potential risk factors that affect early femoral component failures. Therefore, the purpose of this study was to investigate the specific causes of early femoral component failures in hip resurfacing separately and more carefully in order to develop strategies to prevent these failures, rather than excluding groups of patients from this surgical procedure. Methods This retrospective study included 373 metal-on-metal HRAs performed by a single surgeon using the vascular sparing posterior minimally invasive surgical approach. The average length of follow-up was 30 ± 6 months. In order to understand the causes of early femoral failure rate, a multivariable logistic regression model was generated in order to analyze the effects of bone mineral density (T-score, gender, diagnosis, body mass index, femoral implant fixation type, age, and femoral component size. Results The average post-operative Harris hip score was 92 ± 11 points and the average post-operative UCLA score was 7 ± 2 points. There were three revisions due to femoral neck fracture and two for femoral component loosening. These occurred in two female and three male patients. In the multi-variable regression model, only T-score and body mass index showed significant effects on the failure rate of femoral components. Patients with a lower T-score and a higher body mass index had a significantly increased risk of early femoral component failure. Conclusion We recommend that dual energy x-ray absorptiometry scan T-score tests should be routinely performed on all hip resurfacing patients

  7. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10 years followup.

    Science.gov (United States)

    Van Houwelingen, Andrew P; Duncan, Clive P; Masri, Bassam A; Greidanus, Nelson V; Garbuz, Donald S

    2013-02-01

    Currently, the two most commonly used options for the revision of femoral components in North America are: cylindrical, nonmodular, cobalt-chromium stems and tapered, fluted, modular, titanium (TFMT) stems. Previous reports have cited high failure rates with cylindrical cobalt chrome stems in large femoral defects but the longer term survival of the fluted stems is unknown. We examined the 5- to 10-year survival of TFMT stems implanted for severe femoral defects. We reviewed all 65 patients with severe proximal bone defects revised with the TMFT stem between January 2000 and 2006. Ten were lost to followup and seven were dead, leaving 48 patients for followup at 5 to 10 years (mean, 84 months; range, 60-120 months). All patients completed five quality-of-life (QOL) questionnaires. Radiographs were evaluated for loosening, subsidence, and preservation of proximal host bone stock. Implant survivorship was 90%. No patient underwent revision for either subsidence or loosening. Subsidence occurred in seven patients (average, 12.3 mm) but all achieved secondary stability. Five patients underwent revision as a result of fracture of the stem and all had the original standard stem design, which has since been modified. All five implant fractures occurred at the modular stem junction. Mean QOL outcomes were: WOMAC = 81 (pain), Oxford = 75, SF-12 = 54 (mental) and 38 (physical), UCLA Activity = 4, and satisfaction overall = 73. Midterm survivorship of modular titanium stems in large femoral defects is high; however, ongoing surveillance of stem junctional fatigue life is required. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  8. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty?

    Science.gov (United States)

    Müller, M; Abdel, M P; Wassilew, G I; Duda, G; Perka, C

    2015-12-01

    The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck-shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck-shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes. In total, 44 patients (mean age 65.3 years (standard deviation (SD) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (SD 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck-shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes. The mean pre-operative neck-shaft angle was significantly increased by 2.8° from 128° (SD 6.2; 119° to 147°) to 131° (SD 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (SD 8; 7.9 to 39.1) and reduced to 7.4° (SD 7.3; -11.6° to 25.9°) post-operatively (p neck-shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck-shaft angles, but without any impact on clinical outcome.

  9. Spontaneous fracture of the femoral neck in preexisting avascular necrosis of femoral head in sickle cell disease

    Institute of Scientific and Technical Information of China (English)

    Raju Vaishya

    2012-01-01

    Avascular necrosis of the femoral head is a known complication of femoral neck fracture but on the contrary,femoral neck fracture in a case of preexisting avascular necrosis is a very rare phenomenon.We present a case study of a 47 year old Iraqi male who developed spontaneous ipsilateral subcapital femoral neck fracture under the condition of preexisting sickle cell disease and avascular necrosis of the femoral head.The fracture was unnoticed for a few months.The patient was managed successfully by uncemented total hip arthroplasty.Postoperative recovery was uneventful and he was discharged 4 days after surgery.At 1 year's follow-up,the patient had normal gait and hip function,with no sign of loosening or any other complications on radiograph.

  10. [Use of the anatomical cemented femoral stem SAS I: mid-term results].

    Science.gov (United States)

    Mikláš, M; Pink, M; Valoušek, T

    2015-01-01

    is an implant made to fit the proximal femur anatomy. Its highly polished surface allows for optimal fitting with the supporting bone and for even distribution of weight bearing. This results in a low rate of THA failure. In accordance with the relevant literature, the acetabular components is considered to be the weakest element in total hip replacement in terms of aseptic loosening and implant failure. At present, the SAS I stem has no Morse Eurocone taper and this is the chief obstacle hindering its more frequent use in endoprosthetics. CONCLUSIONS The results of our study are in agreement with those of other successfully implanted polished cemented femoral components. Key words: anatomical cemented femoral component, surface adjustment of the femoral stem, complications.

  11. Results of cemented bipolar hemiarthroplasty for fracture of the femoral neck - 10 year study

    Directory of Open Access Journals (Sweden)

    Maini P

    2006-01-01

    Full Text Available Background : One of the most common treatments of displaced fracture of femoral neck in elderly is bipolar hemiarthroplasty. Method : Two hundred and seventy patients of displaced fracture of femoral neck were treated by bipolar hemiarthroplasty. The Mean age of the patients at the time of surgery was 69.80 years. Results : Follow up ranged between 12 months and 120 months. There were 8 cases each of acetabular erosion and protrusion with 10 cases of femoral stem loosening. Eight cases had post operative dislocation requiring open reduction. Eighteen patients got revision surgery to total hip replacement. The overall incidence of DVT/PE was 9.9% which declined after regular use of low molecular weight heparin. Eleven patients had post operative infection. There were 54.2 % excellent results, 21.0 % good results, 10.7 % fair and 3.7% poor results. Conclusion : Elderly patients with displaced fracture of neck femur are able to ambulate early after Cemented bipolar hemi arthroplasty. The complication rate is low, the component survival long and pre injury functional status is restored in majority of patients.

  12. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Science.gov (United States)

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  13. [Loosening of a Calcaneo-Stop Screw after Trampolining].

    Science.gov (United States)

    Trieb, K; Fingernagel, T; Petershofer, A; Hofstaetter, S G

    2015-06-01

    Flexible flatfoot is a common malalignment in the paediatric population. Arthroereisis with a calcaneo-stop screw is an effective surgical procedure for treating juvenile flexible flatfoot after conservative measures have been fully exploited. In the present report, we describe the case of a loosening of a calcaneo-stop screw in a 12-year-old youth after excessive trampolining.

  14. Soil loosening processes in tillage : analysis, systematics and predictability

    NARCIS (Netherlands)

    Koolen, A.J.

    1977-01-01

    The soil movements and the inter-particle forces in the vicinity of an operating tool of a tillage implement may be called a soil tillage process. Examples are the tillage processes of tines, plough-bodies etc. (soil loosening processes) and the influence on the soil of land rollers,

  15. Primary versus secondary distal femoral arthroplasty for treatment of total knee arthroplasty periprosthetic femur fractures.

    Science.gov (United States)

    Chen, Antonia F; Choi, Lisa E; Colman, Matthew W; Goodman, Mark A; Crossett, Lawrence S; Tarkin, Ivan S; McGough, Richard L

    2013-10-01

    Current methods of fixing periprosthetic fractures after total knee arthroplasty (TKA) are variable, and include open reduction and internal fixation (ORIF) via plating, retrograde nailing, or revision using standard revision TKA components or a distal femoral arthroplasty (DFA). The purpose of this study is to compare patients who failed plating techniques requiring subsequent revision to DFA to patients who underwent primary DFA. Of the 13 patients (9.2%) who failed primary ORIF, causes included nonunion (53.8%), infection (30.8%), loosening (7.7%), and refracture (7.7%). There were significantly more surgical procedures for ORIF revision to DFA compared to primary DFA. Complications for patients who underwent primary reconstruction with DFAs included extensor mechanism disruption (8.3%), infection (5.6%), and dislocation (2.8%). Primary reconstruction via ORIF is beneficial for preserving bone stock, but primary DFA may be preferred in osteopenic patients, or those at high risk for nonunion.

  16. Prospective multi-centre study on a composite ceramic femoral component in total knee arthroplasty: Five-year clinical and radiological outcomes.

    Science.gov (United States)

    Bergschmidt, Philipp; Bader, Rainer; Ganzer, Dirk; Hauzeur, Christian; Lohmann, Christoph H; Krüger, Alexander; Rüther, Wolfgang; Tigani, Domenico; Rani, Nicola; Esteve, José Luis; Prats, Fernando Lopez; Zorzi, Claudio; Madonna, Vincenzo; Rigotti, Stefano; Benazzo, Francesco; Rossi, Stefano Marco Paolo; Mittelmeier, Wolfram

    2015-06-01

    Enhanced wear resistance of ceramics in general and improved mechanical characteristics of composite ceramics in terms of strength and resistance meet the demands for application in TKA. The aim of this prospective international multi-centre study was to evaluate the 5-year clinical and radiological outcomes of an unconstrained TKA with a composite ceramic femoral component. A total of 107 patients (109 knees) underwent TKA with the MULTIGEN-PLUS Ceramic Knee at seven centres in three European countries. Clinical and radiological assessments were performed preoperatively and postoperatively at 3, 12, 24 and 60 months, using HSS, WOMAC, SF-36 and standardised radiographs. Mean HSS and WOMAC increased significantly from 55.1±11.5 (21-83) and 48.1±16.6 (3-90) preoperatively to 85.6±9.6 (49-98) and 73.3±20.4 (17-100) at 60 months. Mean SF-36 showed significant improvements in patients' quality of life (49.1±17.6 (12-96) preoperatively versus 67.7±23.1 (12-100) at 60 months). Non-progressive radiolucent lines (ceramic knee is comparable to other metallic and ceramic unconstrained TKA systems. Although the assessment of long-term implant survivorship is still pending, the ceramic implants represent a promising solution for patients with allergies against metallic components and furthermore for the general osteoarthritis population due to enhanced wear resistance. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    NARCIS (Netherlands)

    van der Veen, Hugo; van Jonbergen, H.P.W.; Poolman, R.W.; Bulstra, S.K.; van Raay, J.J.A.M.

    2013-01-01

    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethyle

  18. Aloenxerto circunferencial de fêmur proximal em cirurgias de revisão de artroplastia total de quadril Circumferential proximal femoral allografts in total hip arthroplas ty revision surgery

    Directory of Open Access Journals (Sweden)

    Bruno Dutra Roos

    2012-01-01

    proximal femoral allografts and cemented implants. METHODS: A retrospective study was conducted on 32 patients (33 hips who underwent femoral reconstruction secondary to loosening of total hip arthroplasty, using circumferential proximal femoral allografts and cemented implants. Among these patients, 28 (29 hips fulfilled all the requirements for this study. The mean follow- up was five years and two months. The clinical evaluation was done in accordance with the Harris Hip Score. Radiographically, the patients were assessed regarding reabsorption and consolidation of the allograft, migration of the greater trochanter, stability of the femoral component and heterotypic calcification. RESULTS: The average preoperative Harris Hip Score was 32 points. At the last postoperative follow-up, the average score was 82 points. Allograft resorption of some degree was seen in nine hips (31%. Regarding consolidation, 24 cases (82.8% showed full consolidation, three (10.3% showed partial consolidation and two (6.9% showed pseudarthrosis. All femoral components were stable. According to the criteria established, 27 cases (93.1% were considered to be successful reconstructions after a mean follow-up of five years and two months. CONCLUSIONS: From the results obtained, it was concluded that use of circumferential proximal femoral allografts in selected cases of femoral reconstruction secondary to loosening of arthroplasty presented a high survival rate from the reconstruction over an average follow-up of five years and two months.

  19. Femoral revision surgery with impaction bone grafting

    NARCIS (Netherlands)

    B.L.E.F. ten Have (Bas); R.W. Brouwer (Reinoud); F.C. van Biezen (Frans); J.A.N. Verhaar (Jan)

    2012-01-01

    textabstractThe purpose of this prospective study was to evaluate the long-term clinical and radiological outcomes of revision of the femoral component of a total hip replacement using impaction bone grafting. Femoral revision with an impacted allograft was performed on 29 patients (31 hips). In all

  20. The femoral sulcus in total knee arthroplasty.

    Science.gov (United States)

    Lingaraj, Krishna; Bartlett, John

    2009-05-01

    The position of the femoral sulcus relative to the midline of the distal femoral resection in total knee arthroplasty (TKA) was studied to determine if centralized placement of the femoral component on the distal femur was justified in terms of aligning the prosthetic sulcus with the native femoral sulcus. The location of the femoral sulcus was studied in 112 consecutive patients undergoing TKA. The mean sulcus position was 0.7 mm lateral to the midline of the distal femoral resection (SD 1.4, 95% CI, 0.5-1.0 mm). However, the variation in sulcus positions ranged from 4 mm medial to 4 mm lateral to the midline. The mean sulcus position in valgus knees was 1.0 mm lateral to the midline (SD 1.8), and that in varus knees was 0.7 mm lateral to the midline (SD 1.2) (P = 0.501). It appears prudent to centre the femoral component on the native sulcus rather than the midline of the distal femoral resection, so as to ensure accurate alignment of the prosthetic sulcus with the native sulcus and to encourage normal patella tracking.

  1. Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty.

    Science.gov (United States)

    Hodgson, A; Helmy, N; Masri, B A; Greidanus, N V; Inkpen, K B; Duncan, C P; Garbuz, D S; Anglin, C

    2007-10-01

    The orientation of the femoral component in hip resurfacing arthroplasty affects the likelihood of loosening and fracture. Computer-assisted surgery has been shown to improve significantly the surgeon's ability to achieve a desired position and orientation; nevertheless, both bias and variability in positioning remain and can potentially be improved. The authors recently developed a computer-assisted surgical (CAS) technique to guide the placement of the pin used in femoral head resurfacing arthroplasty and showed that it produced significantly less variation than a typical manual technique in varus/valgus placement relative to a preoperatively determined surgical plan while taking a comparable amount of time. In the present study, the repeatability of both the CAS and manual techniques is evaluated in order to estimate the relative contributions to overall variability of surgical technique (CAS versus manual), surgeon experience (novice versus experienced), and other sources of variability (e.g. across specimens and across surgeons). This will enable further improvements in the accuracy of CAS techniques. Three residents/fellows new to femoral head resurfacing and three experienced hip arthroplasty surgeons performed 20-30 repetitions of each of the CAS and manual techniques on at least one of four cadaveric femur specimens. The CAS system had markedly better repeatability (1.2 degrees) in varus/valgus placement relative to the manual technique (2.8 degrees), slightly worse repeatability in version (4.4 degrees versus 3.2 degrees), markedly better repeatability in mid-neck placement (0.7 mm versus 2.5 mm), no significant dependence on surgeon skill level (in contrast to the manual technique), and took significantly less time (50 s versus 123 s). Proposed improvements to the version measurement process showed potential for reducing the standard deviation by almost two thirds. This study supports the use of CAS for femoral head resurfacing as it is quicker than the

  2. Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem.

    Science.gov (United States)

    Cossetto, David J; Goudar, Anil

    2012-12-01

    To report the mid-term outcome of a modular, cementless, proximally hydroxyapatitecoated, anatomic femoral stem in total hip arthroplasty (THA). 160 consecutive patients aged 42 to 92 (mean, 70) years underwent 185 cementless THAs for primary osteoarthritis or femoral neck fractures. All procedures were performed by a single surgeon using the same modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem, regardless of age and bone quality. Clinical evaluation (pain, range of movement, and ability to walk) was based on the Merle d'Aubigne and Postel scores. Radiological assessment was based on criteria by Engh et al. in the 7 Gruen zones with regard to the presence of radiolucent lines, osteolysis, cancellous condensation, cortical hypertrophy or atrophy, reactive lines, and pedestal formation. Failure of the stem was defined as revision or impending revision because of aseptic loosening or pain. Of the 160 patients, 21 died and none were lost to follow-up. In 3 of the 21 patients, the femoral stems were revised for periprosthetic fractures after a fall at 6 weeks, 10 months, and 3.8 years. 138 patients (162 THAs) completed a mean follow-up of 7.8 (range, 5.5-10.4) years. Their overall mean Merle d'Aubigne and Postel scores increased from 7.09 preoperatively to 16.36 postoperatively. The mean Engh score was 24.9 out of 27, with the mean score for femoral stem fixation 10 out of 10 and 14.9 out of 17 for femoral stem stability. No reactive lines at the bone-stem interfaces and no subsidence or osteolysis were evident in any of the radiographs. There were 5 periprosthetic femoral fractures, 2 deep infections, 3 dislocations, and 2 aseptic loosening (one each for the femoral stem and acetabular socket). Survivorship of the femoral stem at 10 years was 99% when revision secondary to only aseptic loosening of the stem was the endpoint. It was 96% when failures due to all causes (infection, periprosthetic fracture, and aseptic loosening) were the

  3. [Immune competence of human tissue lymphocytes in contact with loosened hip joint prostheses. On the topic of cellular or humoral rejection reaction as the mechanism of loosening].

    Science.gov (United States)

    Peters, K M; Löer, F; Hofstädter, F; Casser, H R

    1991-05-01

    In several investigations rejections were accused of being a possible cause for the loosening of hip endoprostheses. Using immunocytochemical techniques we studied the number and type of lymphocytes in the tissue adjacent to loosened hip endoprostheses. Tissue samples were taken from 18 patients being reoperated for a loosened endoprostheses. Impressive lymphocyte infiltrates were found in 4 of 18 patients (22%). These infiltrates only consisted of T-cells. In the other samples only few lymphocytes were detected belonging to T- and B-lymphocyte population, respectively. In our patients T-cell mediated rejections were of minor importance for the loosening of total hip replacement. B-cell accumulations were detected in none of the samples.

  4. Three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Dept. of Nuclear Medicine, General Hospital of Castelfranco Veneto (Italy); Borsato, N. [Dept. of Nuclear Medicine, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Dept. of Nuclear Medicine, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Dept. of Nuclear Medicine, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Dept. of Nuclear Medicine, General Hospital of Castelfranco Veneto (Italy)

    1995-04-01

    The three-phase bone scintigraphy pattern of loosening in uncemented hip prostheses (UHPs) has not previously been elucidated. We evaluated 28 patients with complicated UHPs who had undergone total hip arthroplasty a very long time previously (range 3-20 years, mean 8.4). All the patients were surgically reviewed: 26 UHPs were found to be loosened and two infected. Nine asymptomatic UHPs were taken as controls. The dynamic phase was invariably negative in both loosened and asymptomatic UHPs while markedly positive in the infected ones. The blood pool phase was positive to various degrees in 16 of the 26 loosened UHPs as well as in the infected UHPs, but was invariably negative in painless replacements. In the bone phase, areas of significantly (discrete to marked) increased uptake were observed in all the loosened prostheses as well as in two-thirds of the asymptomatic ones. However, the regions of the lesser trochanter and/or tip and/or shaft were involved exclusively in the case of the loosened UHPs, and diffuse periprosthetic uptake was found only with loosened or infected implants. Areas of slight methylene diphosphonate (MDP) uptake were found at every periprosthetic site and areas of discrete to marked MDP uptake were commonly found in the acetabulum and/or the greater trochanter with both loosened and painless prostheses and are thus considered to be nonspecific findings. (orig.)

  5. In Vivo Cell Wall Loosening by Hydroxyl Radicals during Cress Seed Germination and Elongation Growth

    NARCIS (Netherlands)

    Muller, K.; Linkies, A.; Vreeburg, R.A.M.; Fry, S.C.; Krieger-Liszkay, A.; Leubner-Metzger, G.

    2009-01-01

    Loosening of cell walls is an important developmental process in key stages of the plant life cycle, including seed germination, elongation growth, and fruit ripening. Here, we report direct in vivo evidence for hydroxyl radical (·OH)-mediated cell wall loosening during plant seed germination and se

  6. Femoral hernia causing pneumoperitoneum.

    OpenAIRE

    King, H. A.; Boulter, P. S.

    1986-01-01

    Richter's hernia, in which only a portion of the circumference of the intestine lies within the sac, is a common complication of femoral hernia. This case report is of 39 year old female who presented with a pneumoperitoneum and was found at laparotomy to have a right femoral Richter's hernia containing a knuckle of perforated small bowel. This is a previously unreported presentation of femoral hernia.

  7. Femoral hernia repair

    Science.gov (United States)

    Femorocele repair; Herniorrhaphy; Hernioplasty - femoral ... During surgery to repair the hernia, the bulging tissue is pushed back in. The weakened area is sewn closed or strengthened. This repair ...

  8. The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs.

    Science.gov (United States)

    Hutt, Jonathan; Hazlerigg, Alexandra; Aneel, Ansari; Epie, Geoffrey; Dabis, Husam; Twyman, Roy; Cobb, Andrew

    2014-06-01

    The optimal design for a cemented femoral stem remains a matter of debate. Over time, the shape, surface finish and collar have all been modified in various ways. A clear consensus has not yet emerged regarding the relative merits of even the most basic design features of the stem. We undertook a prospective randomised trial comparing surface finish and the effect of a collar on cemented femoral component subsidence, survivorship and clinical function. One hundred and sixty three primary total hip replacement patients were recruited prospectively and randomised to one of four groups to receive a cemented femoral stem with either a matt or polished finish, and with or without a collar. At two years, although there was a trend for increased subsidence in the matt collarless group, this was not statistically significant (p = 0.18). At a mean of 10.1 years follow-up, WOMAC scores for the surviving implants were good, (Range of means 89-93) without significant differences. Using revision or radiographic loosening as the endpoint, survivorship of the entire cohort was 93 % at 11 yrs, (CI 87-97 %). There were no significant differences in survivorship between the two groups with polished stems or the two groups with matt stems. A comparison of the two collarless stems demonstrated a statistically significant difference in survivorship between polished (100 %) and matt (88 %) finishes (p = 0.02). In the presence of a collar, surface finish did not significantly affect survivorship or function. Between the two collarless groups a polished surface conferred an improved survivorship.

  9. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral c...

  10. Hemiarthroplasty for Displaced Femoral Neck Fractures in the Elderly Has a Low Conversion Rate.

    Science.gov (United States)

    Grosso, Matthew J; Danoff, Jonathan R; Murtaugh, Taylor S; Trofa, David P; Sawires, Andrew N; Macaulay, William B

    2017-01-01

    Hemiarthroplasty (HA) has been a mainstay treatment for displaced femoral neck fractures for many years. The purpose of this study was to report the conversion rate of HA to total hip arthroplasty (THA) for displaced femoral neck fractures and compare outcomes between implant constructs (bipolar vs unipolar), fixation options (cemented vs cementless stems), and age groups (fractures at our institution between 1999 and 2013 with a minimum of 2-year follow-up. The overall component revision rate, including conversion to THA, revision HA, revision with open reduction internal fixation, and Girdlestone procedure, was 5.6% (39/686). Seventeen patients (2.5%) were converted from HA to THA at an average of 1.9 years after index procedure. A significantly lower conversion rate of 1.4% (7/499 patients) was found in the older patient cohort (≥75 years old) compared to 5.3% (11/187) in the younger cohort. The most common causes for conversion surgery to THA were acetabular wear (5 patients), aseptic loosening (4 patients), and periprosthetic fracture (3 patients). There was a significantly lower rate of periprosthetic fracture (0.4% vs 2.5%, P value .025) in the cemented implant group compared to the cementless group. We observed a higher rate of dislocations in the bipolar vs unipolar group (3.8% vs 1%, P value .02) and no other significant differences between these groups. We observed a low reoperation rate for this cohort of patients, relatively higher conversion rates for the younger population, fewer periprosthetic fractures with the use of cemented stems, and no advantage of bipolar over unipolar prostheses. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Retrograde femoral nailing in elderly patients: outcome and functional results.

    Science.gov (United States)

    Neubauer, Thomas; Krawany, Manfred; Leitner, Lukas; Karlbauer, Alois; Wagner, Michael; Plecko, Michael

    2012-06-01

    Functional outcome after retrograde femoral intramedullary nailing was investigated in 35 patients older than 60 years (mean, 86 years) with 36 fractures, comprising 15 (41.7%) shaft and 21 (58.3%) distal fractures; overall, 7 (19.4%) periprosthetic fractures occured. Twenty-two (62.9%) of 35 patients were evaluated at a mean 16.5-month follow-up with the Lyshom-Gillquist score and the SF-8 questionaire. Primary union rate was 97.8%, with no significant differences in duration of surgery, bone healing, mobilization, and weight bearing among different fracture types; periprosthetic fractures revealed a significantly delayed mobilization (P=.03). Complications occured significantly more often among distal femoral fractures (P=.009), including all revision surgeries. The most frequently encountered complication was loosening of distal locking bolts (n=3). Lysholm score results were mainly influenced by age-related entities and revealed fair results in all fractures (mean in the femoral shaft fracture group, 78.1 vs mean in the distal femoral fracture group, 74.9; P=.69), except in the periprosthetic subgroup, which had good results (mean, 84.8; P=.23). This group also had increased physical parameters according to SF-8 score (P=.026). No correlation existed between SF-8 physical parameters and patient age or surgery delay, whereas a negative correlation existed between patient age and SF-8 mental parameters (P=.012). Retrograde femoral intramedullary nailing is commonly used in elderly patients due to reliable bone healing, minimal soft tissue damage, and immediate full weight bearing. It also offers a valid alternative to antegrade nailing in femoral shaft fractures.

  12. Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips.

    Science.gov (United States)

    Flecher, Xavier; Appy, Benjamin; Parratte, Sébastien; Ollivier, Matthieu; Argenson, Jean-Noel

    2017-05-01

    Recent studies have reported short-term favourable results of tantalum-made components in acetabular revisions with bone loss. However, there is a lack of information regarding the mid to long-term results of such components. The objective of this study was to analyse the outcome and survivorship of acetabular revision hip arthroplasty using tantalum components for loosening associated with bone loss at a minimum of five-year follow-up. We retrospectively reviewed 51 consecutive patients (51 hips) who had an acetabular revision using porous tantalum components at a minimum follow-up of five years. The mean age was 64 years (range, 31-87). There were 27 males and 24 females, 47 right hips and four left hips. Twenty-five (49 %) included a femoral revision. According to Paprosky's classification 18 hips were classified type 2A, 11 type 2B, ten type 2C, seven type 3A and five type 3B. No bone grafting was performed. Sixteen hips (31.3 %) required the use of additional tantalum-made augments stabilized by screws and cement at the cup-augment interface. At a mean followup of 6.8 years (range, 5.1-10 years), the Harris hip score improved from 44 pre- operatively (range, 23-72) to 84 post-operatively (range, 33-98). The mean post-operative hip centre position in relation to the teardrop was 29 mm (range, 20-43 mm) horizontally and 21 mm (range, 8-36 mm) vertically. The mean acetabular inclination was 42° (range, 17-60°). Six hips (11.7 %) required a re-operation without component revision (two for chronic instability, one ossification removal, one haematoma, one deep infection and one periprosthetic femoral fracture). One patient required a cup re-revision for septic loosening. No aseptic loosening occurred. At last followup the radiological analysis showed one evolutive osteolysis and one screw breakage. The global survivorship was 92.3 % at 64 months. If only aseptic loosening was defined as the end-point the survivorship was 100 % at 64 months. When

  13. Outcome and complications of constrained acetabular components.

    Science.gov (United States)

    Yang, Cao; Goodman, Stuart B

    2009-02-01

    Constrained acetabular liners were developed for the surgical treatment of recurrent instability by holding the femoral head captive within the socket. This article summarizes the data describing constrained component designs, indications, outcome, and complications. Different designs accept head sizes of varying diameter and have differing amounts of rim elevation and offset, allowing slight variations in the range of movement allowed. Complications of constrained acetabular components can be divided into three categories. The first category is directly related to the constraining mechanism such as dislocation, head dissociation from the stem, liner dissociation from the acetabular device, and impingement with or without locking ring breakage. The second category is related to increased constraint such as aseptic component loosening and osteolysis and periprosthetic fracture. The third category includes those cases not associated with increased constraint such as infection, deep vein thrombosis, and periprosthetic fracture. This device is effective at achieving hip stability, but the complications related to the constraining mechanism and increased constraint are of concern. These devices should be used as a salvage measure for the treatment of severe instability.

  14. Related Analysis between the Interface Membrane and Loosening Prosthesis of Hip

    Institute of Scientific and Technical Information of China (English)

    Ma Jianbing; Zhang Yuming; Meng Xiangdong; Liu Miao

    2009-01-01

    Objective: To analyze the reason of loosening prosthesis by observing the interface membranes harvested during the hip revision operation. Methods: 28 specimens of interface membrane around the loosening prosthesis were harvested from 28 patients who underwent the revision of total hip replacement. All the specimens were observed by appearance, light microscope and scanning electronic microscope (SEM). Results: All the gap around the loosening prothesis were filled with different thickness of interface membranes. The color of the most interface membranes was madder red, and other one third of membranes was black. The thicker membrane was similar to scar connective tissue, the thinner was similar to fiber membrane. A large number of wear debris, macrophage and foreign-body giant cells were found under light microscope. With SEM observation, a large number of different diameter collagen fibra structures looked like scar tissue arranged disorderly in a great mass, different size of foreign particles and bone debris distributed unevenly, and the fibroblast distributed in the collagen fiber. Conclusion: Wear debris is relevant to inflammatory cells response around the interface membrane of the loosening prosthesis. The wear debris engulfed by macrophage stimulated the interface membrane to release bone resorption factors (such as TNF) which lead to osteolysis, and this was one of the most importment reasons of the prosthesis loosening.

  15. Developing a highly reliable cae analysis model of the mechanisms that cause bolt loosening in automobiles

    Directory of Open Access Journals (Sweden)

    Ken Hashimoto

    2014-10-01

    Full Text Available In this study, we developed a highly reliable CAE analysis model of the mechanisms that cause loosening of bolt fasteners, which has been a bottleneck in automobile development and design, using a technical element model for highly accurate CAE that we had previously developed, and verified its validity. Specifically, drawing on knowledge gained from our clarification of the mechanisms that cause loosening of bolt fasteners using actual machine tests, we conducted an accelerated bench test consisting of a threedimensional vibration load test of the loosening of bolt fasteners used in mounts and rear suspension arms, where interviews with personnel at an automaker indicated loosening was most pronounced, and reproduced actual machine tests with CAE analysis based on a technical element model for highly accurate CAE analysis. Based on these results, we were able to reproduce dynamic behavior in which larger screw pitches (lead angles lead to greater non-uniformity of surface pressure, particularly around the nut seating surface, causing loosening to occur in areas with the lowest surface pressure. Furthermore, we implemented highly accurate CAE analysis with no error (gap compared to actual machine tests.

  16. An experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane

    Directory of Open Access Journals (Sweden)

    Akens Margarete K

    2004-03-01

    . Nitric oxide (NO and PGE2 concentrations were higher in the 8.5 months group (P Conclusion In this study, a primary cement mantle defect of the femoral shaft elicited biomechanical instability and biochemical changes over time in an experimental animal study in sheep, that resembled the changes described at the bone cement-interface in aseptic loosening of total hip prosthesis in humans. The early biochemical changes may well explain the pathologic bone resorption and formation of an interface membrane as is observed in clinical cases. This animal model may aid in future studies aiming at prevention of aseptic loosening of hip prosthesis and reflect some aspects of the pathogenesis involved.

  17. Component

    Directory of Open Access Journals (Sweden)

    Tibor Tot

    2011-01-01

    Full Text Available A unique case of metaplastic breast carcinoma with an epithelial component showing tumoral necrosis and neuroectodermal stromal component is described. The tumor grew rapidly and measured 9 cm at the time of diagnosis. No lymph node metastases were present. The disease progressed rapidly and the patient died two years after the diagnosis from a hemorrhage caused by brain metastases. The morphology and phenotype of the tumor are described in detail and the differential diagnostic options are discussed.

  18. Relationship between GNAS1 T393C polymorphism and aseptic loosening after total hip arthroplasty.

    Science.gov (United States)

    Stelmach, Patrick; Kauther, Max D; Fuest, Lena; Kurscheid, Gina; Gehrke, Thorsten; Klenke, Stefanie; Jäger, Marcus; Wedemeyer, Christian; Bachmann, Hagen S

    2017-08-23

    Aseptic loosening is a main cause for revision surgery after total hip arthroplasty (THA) and there is no reliable marker for the early detection of patients at high risk. This study has been performed to validate association of the T393C polymorphism (rs7121) in the GNAS1 gene, encoding for the alpha-subunit of heterotrimeric G-protein Gs, with risk for and time to aseptic loosening after THA, which has been demonstrated in our previous study. 231 patients with primary THA and 234 patients suffering from aseptic loosening were genotyped for dependency on GNAS1 genotypes and analyzed. Genotyping revealed almost similar minor allele frequencies of 0.49 and 0.46, respectively. Consistently, genotype distributions of both groups were not significantly different (p = 0.572). Neither gender nor GNAS1 genotype showed a statistically significant association with time to loosening (p = 0.501 and p = 0.840). Stratification by gender, as performed in our previous study, was not able to show a significant genotype-dependent difference in time (female p = 0.313; male p = 0.584) as well as median time to aseptic loosening (female p = 0.353; male p = 0.868). This study was not able to confirm the results of our preliminary study. An association of the GNAS1 T393C polymorphisms with risk for and time to aseptic loosening after THA is unlikely.

  19. Diabetes Mellitus and Hyperglycemia and the Risk of Aseptic Loosening in Total Joint Arthroplasty.

    Science.gov (United States)

    Maradit Kremers, Hilal; Schleck, Cathy D; Lewallen, Eric A; Larson, Dirk R; Van Wijnen, Andre J; Lewallen, David G

    2017-09-01

    It is unknown to what extent diabetes mellitus modifies the long-term risk of aseptic loosening in total hip arthroplasty (THA) and total knee arthroplasty (TKA). We examined the association between diabetes mellitus, perioperative hyperglycemia, and the likelihood of revisions for aseptic loosening. We studied 16,085 primary THA and TKA procedures performed at a large tertiary care hospital between 2002 and 2009. All blood glucose values around the time of surgery (within 1 week) were retrieved. Subsequent revision surgeries and the reasons for revision were ascertained through the institutional joint registry. Multivariate Cox models were used to estimate the hazard ratios (HRs) and 95% confidence intervals (CIs) for aseptic loosening associated with diabetes mellitus and hyperglycemia adjusting for age, gender, body mass index, and surgery type. A total of 2911 (18%) surgeries had a diagnosis of diabetes mellitus at the time of surgery. Glucose testing was performed at least once in 7055 (44%) procedures within ±1 week of surgery. Although diabetic patients did not experience a higher risk of revision for aseptic loosening (HR, 0.87; 95% CI, 0.55-1.38), higher preoperative glucose values on the day before surgery were significantly associated with both the overall risk of revisions (HR, 2.80; 95% CI, 1.00-7.85) and revisions for aseptic loosening (HR, 4.95; 95% CI, 1.26-19.54). High preoperative hyperglycemia is a potential risk factor for aseptic loosening in THA and TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Reactivation of a tuberculous coxitis due to loosening of a total hip endoprosthesis.

    Science.gov (United States)

    Fink, B; Casser, H R; Zilkens, K W; Rüther, W

    1995-01-01

    A 45-year-old woman who suffered from juvenile tuberculous coxitis at the age of 4 is presented. Her hip joint replacement lasted for 18 years and then needed replacing. Intraoperatively removed caseous soft tissue and an opalescent secretion histologically resembled a tuberculous focus, and bacteriological culture grew a Mycobacterium tuberculosis strain. Four months after the replacement, the patient suffered from a tuberculosis-induced septic loosening of the newly replaced hip joint endoprosthesis. The tuberculosis relapse was probably due to aseptic loosening of the first hip joint endoprosthesis.

  1. [Subtrochanteric femoral fractures].

    Science.gov (United States)

    Ulmar, B; Simon, S; Eschler, A; Mittlmeier, T

    2013-12-01

    Subtrochanteric femoral fractures are proximal femoral fractures which are located between the trochanter minor and an area of 3 cm below the minor trochanter on the femoral shaft. About 10-15% of all proximal femoral fractures correspond to this fracture site. Elderly or geriatric patients are generally affected and the injury is often the result of a fall in the home, while high-energy trauma is the cause in a small group of generally younger patients. Clinical evaluation of the affected extremity shows disability of axial weight-bearing and pain during compression and rotation of the hip joint. Basic diagnostics include conventional x-rays of the injured femur in the anterior-posterior and lateral planes. These subtrochanteric femoral fractures are almost always treated surgically due to the inherent high degree of instability. The main goals of surgical intervention are to achieve anatomic fracture reduction and primary full weight-bearing stability of the corresponding leg. Intramedullary interlocking nails are used for primary treatment, while extramedullary implants are often used in revision surgery. Early mobilization and intensive respiratory exercises are necessary to prevent early postoperative complications.

  2. Femoral varus: what's the angle

    DEFF Research Database (Denmark)

    Miles, James Edward; Svalastoga, Eiliv Lars; Eriksen, Thomas

    Agreement and reliability of femoral varus measurements: a comparison of four techniques Three different techniques have been described for measuring femoral varus radiographically in the dog, but how the measurements from these techniques compare is unknown. Further, measurement reliability has ...

  3. 全膝人工关节股骨假体屈曲对疗效的影响:1年随访结果%Effect of femoral component flexion in total knee arthroplasty One-year follow-up results One-year follow-up results

    Institute of Scientific and Technical Information of China (English)

    张洪美; 张志强; 孙钢; 赵铁军; 顾力军; 陈卫衡; 尹天; 刘道兵; 张淳; 谢斌

    2008-01-01

    BACKGROUND:The majority of people do not believe that the femoral component flexion in total knee arthroplasty affect or affect little postoperative function and it is the only that the radiographic films is not satisfactory.So it has not caused people's enollgh attention.But the femoral component flexion affects the results of total knee arthroplasty obviously.OnJECTIVE:To investigate the curative effects of femoral component installed in the position of flexion during the operative procedure of total knee arthroplasty(123 knees)on the follow up results in 78 patients.DESIGN:Grouping contrast observation.SETTlNG:First Department of Bone and Joint,Wangjing Hospital of China Academy of Traditional Cllinese Medicine.PARTlCIPANTS:123 knees(78 patients)were given total knee arthroplasty in the First Department of Bone and Joint,Wangjing Hospital of China Academy of Traditional Chinese Medicine from October 2001 to June 2004.Seventeen(13.8%,15 patients)knees were found with femoral component flexion(FCF),in which there were 5 male cases and 10 female cases,aged from 47 to 81 years old.106(63 patients)knees were found without FCF,in which there were 22 male cases and 41 female cases,aged from 47 to 79 years old.METHODS:Total knee arthroplasties about their HSS rating scores,ranges of motion and flexion contractures werecompared in the two groups before operation and after operation,and the degrees of the FCF angle and the distances of femoral component flexion were measured.MAIN OUTCOME MEASURES:①Femoral Drostllesis flexion measurement;②HSS scores and activity:③femoral prosthesis flexion angle and distance buckling;④adverse events and side effects.RESULTS:Follow up lasted for one year above.①The degrees of flexion of femoral components were from 7°to 19°(average 11.3°)and the distance of flexion was from 2 mm to 4 mm(average 2.6 mln)in those 17 knees of total knee arthroplasty.②Differences in HSS rating scores and range of motion were not statistically

  4. Treatment of periprosthetic femoral fractures with modular stems.

    Science.gov (United States)

    Hernandez-Vaquero, Daniel; Fernandez-Lombardia, Jesus; de los Rios, Jimena Llorens; Perez-Coto, Ivan; Iglesias-Fernandez, Susana

    2015-10-01

    The purpose of this study was to analyse the efficacy of modular femoral stems for the treatment of certain post-operative periprosthetic fractures in patients with hip arthroplasty. Of a total series of 61 modular revision stems, 17 were used to address periprosthetic femoral fractures and 12 of these are the object of this study. The average follow-up was 3.7 years (range 1-14 years). The evaluations were performed at three and six months, and then annually using the HHS score and radiographic studies for the assessment of loosening, subsidence and bone integration of the stem. Seven cases had type B2 fractures and five type B3 ones. All patients walked freely, eight of them using canes. HHS improved to a post-operative mean of 78 (range 72-83). Radiographically, fracture healing was observed at three months in nine cases. In six cases stem subsidence of a mean of 3.9 mm (range 2-12 mm) was observed, which stabilized a year following implantation and did not need revision surgery. In two cases a subsequent dislocation (at three and seven months after surgery) occurred, which were treated with constrained acetabular systems. In nine cases hypotrophy of the cortex in the diaphyseal area was noted, which did not alter the patients' clinical course. Modular femoral stems are an acceptable treatment in type B2 and B3 periprosthetic fractures.

  5. Laparoscopic repair of femoral hernia

    OpenAIRE

    Yang, Xue-Fei; Liu, Jia-Lin

    2016-01-01

    Laparoscopic repair of inguinal hernia is mini-invasive and has confirmed effects. Femoral hernia could be repaired through the laparoscopic procedures for inguinal hernia. These procedures have clear anatomic view in the operation and preoperatively undiagnosed femoral hernia could be confirmed and treated. Lower recurrence ratio was reported in laparoscopic procedures compared with open procedures for repair of femoral hernia. The technical details of laparoscopic repair of femoral hernia, ...

  6. Loosening of Total Knee Arthroplasty after Brucellosis Infection: A Case Report

    Science.gov (United States)

    Sazegari, Mohammad Ali; Bahramian, Fateme; Mirzaee, Fateme; Zafarani, Zohreh; Aslani, Hamidreza

    2017-01-01

    In this report we describe a 78-year-old man whose total knee arthroplasty showed the symptoms of infection with brucella with radiographic signs of loosening 5 years after the index surgery. The patient was treated successfully after a 2-stage revision arthroplasty surgery along with using rifampicin and doxycycline for 8 weeks. PMID:28271092

  7. Normal neurodynamic responses of the femoral slump test.

    Science.gov (United States)

    Lai, Weng-Hang; Shih, Yi-Fen; Lin, Pei-Ling; Chen, Wen-Yin; Ma, Hsiao-Li

    2012-04-01

    Femoral slump test is a neurodynamic testing, which could be used to assess the mechanosensitivity of the femoral component of the nervous system. Although Trainor and Pinnington reported the diagnosis accuracy of the femoral slump test, the neurodynamic responses of the femoral slump test have never been studied. The purposes of this study were to evaluate whether maneuvers that changed the nerve tension altered the responses of the femoral slump test and if these responses were influenced by gender and leg dominance; and to identify the correlations between flexibility and measured hip extension angle. Thirty-two asymptomatic subjects (16 males, 16 females) were recruited. The femoral slump test was performed in trunk slump and neutral positions, and cervical extension was used as the structure differential technique. Hip extension angle and visual analog scale (VAS) of thigh pain was measured during the test. Our results showed the decrease of nerve tension significantly increased hip extension ROM (P  0.05). These findings indicated that femoral slump test resulted in normal neurodynamic responses in individuals free of lower extremity problems, and these responses were independent of the influence of muscle flexibility or gender. Future research should emphasize the use of femoral slump test in patient groups such as low back and anterior knee pain.

  8. The Exeter Contemporary flanged cemented acetabular component in primary total hip arthroplasty.

    Science.gov (United States)

    Maggs, J L; Smeatham, A; Whitehouse, S L; Charity, J; Timperley, A J; Gie, G A

    2016-03-01

    We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. Kaplan-Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty. ©2016 The British Editorial Society of Bone & Joint Surgery.

  9. Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement

    DEFF Research Database (Denmark)

    Gallo, Jiri; Vaculova, Jana; Goodman, Stuart B;

    2014-01-01

    Aseptic loosening and osteolysis are the most frequent late complications of total hip arthroplasty (THA) leading to revision of the prosthesis. This review aims to demonstrate how histopathological studies contribute to our understanding of the mechanisms of aseptic loosening/osteolysis developm...

  10. Anthropometric measurements to design best-fit femoral stem for the Indian population.

    Science.gov (United States)

    Rawal, Br; Ribeiro, Rahul; Malhotra, Rajesh; Bhatnagar, Naresh

    2012-01-01

    The standard commercially available marketed prostheses sometimes may not be the best fit to Indian patients because of the large anatomic variation. Orthopedic surgeons always stress the need for a proper implant-patient match in hip joint replacements, in particular, for a cementless femoral stem. The complications of mismatch are aseptic loosening, improper load distribution, and discomfort. The present study was undertaken to compare the differences in dimensions between femurs of elderly Indians and those of populations from other regions in order to solve the problem of a possible geometric mismatch between a selected implant and the hip joint as far as Indian patients are concerned. Measurements were made using computer aided design techniques on computed tomography (CT) scanned images of 98 femurs (56 left and 42 right). The software used to convert the CT images into solid models was MIMICS(®) (Materialize, Inc., Leuven, Belgium). The geometrical parameters, viz., the femoral head offset, femoral head center (HC), femoral head diameter, femoral head relative position, position of shaft isthmus, neck-shaft angle, bow angle, femoral neck length, canal flare index, femoral length, and canal width at various locations, were chosen to design best-fit standard femoral stems for cementless insertion. These data were compared with the published data of other countries. A difference of 16.8% was found in the femoral head offset between Indian and Swiss populations, which can affect soft tissue tension and range of motion. At a distance of 20 mm above the lesser trochanter (LT), the anteroposterior (AP) canal width was found to differ by 45.4%, when compared with a French population which can affect the mechanical stability of femoral stem. Femoral dimensions of Indian male and female subjects have also been compared and differences evaluated. At the LT, the aspect ratio (ratio of mediolateral canal width and AP canal width) in case of males (1.198) is

  11. Deep reclamation loosening of soils: State of the problem, results of research, prospects of application, and degradation changes

    Science.gov (United States)

    Zaidel'man, F. R.

    2016-09-01

    The efficiency of deep reclamation loosening used for soils of different types on the main parent rocks in the Nonchernozemic zone (mantle and moraine loams, Permian and varved loamy clays, and clays) is assessed basing on the results of long-term stationary and analytical investigations. The long-term aftereffect of the deep loosening on the density, porosity, water permeability, and the main elements of the soil water regime and factors limiting the use of deep loosening are considered. Over 6-12 years after the deep loosening, in the area, where active and passive loosening by a plough was made, a zone of elevated water permeability is preserved at the depth of 40-75 cm. Based on this phenomenon, a new technology of deep reclamation loosening, which restores the hydraulic connection between the arable and deeper soil layers, is proposed. The data on active deep rippers that provide soil loosening to the depth of 0.9-1.0 m are presented. Some agroecological aspects related to the duration of deep loosening effects on the soils and their productivity are discussed. Recommendations on the application of passive and active loosening and moling of heavy-textured gleyed soils are suggested for the European part of the Nonchernozemic zone in the Russian Federation. Field and laboratory works on estimating the efficiency of deep loosening continued for 15 years (1976-1990) for heavy-textured soils on the loess-like, fine-stratified varved clays, as well as on acid moraine and calcareous Permian clays and loamy clays in Moscow, Vologda, Novgorod, and Kirov oblasts.

  12. Estimation of pretraumatic femoral antetorsion in bilateral femoral shaft fractures

    Energy Technology Data Exchange (ETDEWEB)

    Citak, Musa; Jagodzinski, Michael; Krettek, Christian; Huefner, Tobias [Hannover Medical School, Trauma Department, Hannover (Germany); Citak, Mustafa [BG-University Hospital Bergmannsheil, Department of Surgery, Bochum (Germany); Kendoff, Daniel; O' Loughlin, Padhraig F. [Hospital for Special Surgery, Orthopaedic Department, New York, NY (United States); Tavassol, Frank [Hannover Medical School, Department of Oral and Maxillofacial Surgery, Hannover (Germany)

    2009-12-15

    To describe a system for measurement of the pretraumatic femoral antetorsion angle post-bilateral femoral shaft fracture with the use of new imaging software which allows segmentation and three dimensional (3D) reconstruction of DICOM (digital imaging and communications in medicine) images. This case involved a 20-year-old patient with bilateral femoral shaft fractures. Following initial clinical examination, CT scans of both femurs were performed. Subsequently, the DICOM datasets were uploaded to the new software tool. Following segmentation and 3D reconstruction, pretraumatic femoral antetorsion angles were determined. Femoral antetorsion was described and assessed in two ways by referring to the intersection of the posterior condylar plane and (1) a line drawn between the center of the femoral head and femoral neck, (2) a line drawn between the centers of the femoral head and greater trochanter. Using these definitions, values for femoral antetorsion were found to be, respectively, 20 at the right fracture site and 19 on the left site, and 33 bilaterally. The investigators describe in this current technical report the use of new imaging software which enables the calculation of femoral AV following reduction of virtual fracture fragments which are created from standard DICOM images. We believe that this 3D reconstruction method of measuring the antetorsion angle can be integrated into a regular treatment algorithm and may potentially optimize clinical outcomes. (orig.)

  13. Femoral impaction bone grafting in revision hip arthroplasty: 705 cases from the originating centre.

    Science.gov (United States)

    Wilson, M J; Hook, S; Whitehouse, S L; Timperley, A J; Gie, G A

    2016-12-01

    Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time. Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died. There were 76 further revisions (10.8%) involving the stem; seven for aseptic loosening, 23 for periprosthetic fracture, 24 for infection, one for malposition, one for fracture of the stem and 19 cement-in-cement exchanges of the stem during acetabular revision. The 20-year survival rate for the entire series was 98.8% (95% confidence interval (CI) 97.8 to 99.8) with aseptic loosening as the endpoint, and 87.7% (95% CI 82.8 to 92.6) for revision for any reason. Survival improved with the evolution of the technique, although this was not statistically significant due to the overall low rate of further revision. This is the largest series of revision total hip arthroplasties with femoral impaction grafting, and the results support the continued use of this technique. Cite this article: Bone Joint J 2016;98-B:1611-19. ©2016 The British Editorial Society of Bone & Joint Surgery.

  14. SIRT1 protects osteoblasts against particle-induced inflammatory responses and apoptosis in aseptic prosthesis loosening.

    Science.gov (United States)

    Deng, Zhantao; Wang, Zhenheng; Jin, Jiewen; Wang, Yong; Bao, Nirong; Gao, Qian; Zhao, Jianning

    2017-02-01

    We hypothesized that SIRT1 downregulation in osteoblasts induced by wear particles was one of the reasons for particle-induced osteolysis (PIO) in total joint arthroplasty failure. In the present study, the expression of SIRT1 was examined in osteoblasts treated with TiAl6V4 particles (TiPs) and CoCrMo particles (CoPs) from materials used in prosthetics and specimens from PIO animal models. To address whether SIRT1 downregulation triggers inflammatory responses and apoptosis in osteoblasts, the effect of a SIRT1 activator, resveratrol on the expression of inflammatory cytokines and apoptosis in particle-treated osteoblasts was tested. The results demonstrated that SIRT1 expression was significantly downregulated in particle-treated osteoblasts and PIO animal models. Both pharmacological activation and overexpression of SIRT1 dramatically reduced the particle-induced expression of inflammatory cytokines and osteoblast apoptosis through NF-κB and p53 signaling, respectively. Furthermore, in PIO animal models, resveratrol significantly reduced the severity of osteolysis. Collectively, the results of the present study indicated that SIRT1 plays a vital role in the pathogenesis of aseptic loosening, and further treatment targeted at SIRT1 possibly lead to novel approaches for prevention of aseptic prosthesis loosening. Aseptic loosening is the most common cause of total hip arthroplasty (THA) and total knee arthroplasty (TKA) failure and revision surgery. However, there is still no effective therapeutic target in the clinical treatment. Besides, the underlying mechanism of aseptic loosening is largely unknown. The result of our study indicated that SIRT1 has the ability to effectively regulate the wear particle-induced inflammatory responses, apoptosis, osteolysis in particle-stimulated osteoblasts and particle-induced osteolysis animal models. Our study provides a potential target for the prevention and treatment of aseptic loosening and further investigated the

  15. Experimental fixation of femoral osteotomies by cerclage with nylon straps.

    Science.gov (United States)

    Rhinelander, F W; Stewart, C L

    1983-10-01

    Following the successful experience of Partridge in the fixation of human femoral fractures by nylon-strap cerclage, this research in 23 mature dogs was performed to compare nylon-strap with wire-loop cerclage for healing periods of up to 12 weeks. Supplemented by intramedullary fixation with Steinmann pins, long oblique femoral osteotomies were fixed in one femur of each dog by nylon straps and in the other femur by wire loops, at separate operations. The nylon straps were all secured at the same tension by a special "gun." The wire loops were all secured at the same tension by the Rhinelander tightener-twister. Half of the nylon straps had "bumps" along the inner surface, which were added by Partridge in an effort to circumvent the microvascular disturbance reported with Parham bands. On examination by microangiography and correlated histology, all of the osteotomies, regardless of the type of fixation, showed good progress toward osseous union. After fixation by wire cerclage no loss of position or disturbance of blood supply was noted. After fixation by nylon straps slight (clinically insignificant) longitudinal displacement, attributed to slight lengthening of the straps, with consequent loosening was noted in all cases. This loosening was considered advantageous because it appeared to be responsible for the unexpected lack of impairment of the vascularization of the underlying cortical bone by any of the straps. The bumps on the undersurface of some of the straps were, thus, of no vascular advantage, and their presence made accurate fixation of the ostectomy fragments more difficult on the small bones. These studies support the value of fixation by plain nylon straps and show their advantage over straps with bumps for fixation of long oblique single osteotomies of bones the size of the canine femur.

  16. Radiation induced femoral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Aranda, B.; Esnault, S.; Brunet, P. (Hopital de la Salpetriere, Paris (France))

    1982-01-01

    We report four cases of femoral palsy due to compressive fibrosis, after pelvic radiation therapy. Three patients had Hodgkin's disease, and one testicular seminoma. Prominent clinical features include major groin induration and underlying swelling. Unlike what is usually seen in tumoral relapse, little or no pain is associated with these neuropathies. The femoral post-radic palsy develops earlier and faster than brachial plexus palsy of same aetiology. In one case, progressive aggravation led to surgical neurolysis which resulted in dramatic and long lasting improvement. The principal preventive and therapeutic management methods are discussed: since compressive fibrosis is related to the use of isolated and massive electron beam therapy, various associations of cobalt and electron beam therapy are designed to best prevent the side effects of each of these methods. The early treatment of developing fibrosis by D. penicillamine is discussed.

  17. Proximal femoral fractures

    DEFF Research Database (Denmark)

    Palm, Henrik; Teixidor, Jordi

    2015-01-01

    BACKGROUND: In hip fracture surgery, the exact choice of implant often remains somewhat unclear for the individual surgeon, but the growing literature consensus has enabled publication of evidence-based surgical treatment pathways. The aim of this article was to review author pathways and national...... guidelines for hip fracture surgery and discuss a method for future pathway/guideline implementation and evaluation. METHODS: By a PubMed search in March 2015 six studies of surgical treatment pathways covering all types of proximal femoral fractures with publication after 1995 were identified. Also we...... searched the homepages of the national heath authorities and national orthopedic societies in West Europe and found 11 national or regional (in case of no national) guidelines including any type of proximal femoral fracture surgery. RESULTS: Pathway consensus is outspread (internal fixation for un...

  18. Proximal Focal Femoral Deficiency

    Directory of Open Access Journals (Sweden)

    Vishal Kalia, Vibhuti

    2008-01-01

    Full Text Available Proximal focal femoral deficiency (PFFD is a developmental disorder of the proximal segment of thefemur and of acetabulum resulting in shortening of the affected limb and impairment of the function. It isa spectrum of congenital osseous anomalies characterized by a deficiency in the structure of the proximalfemur. The diagnosis is often made by radiological evaluation which includes identification and descriptionof PFFD and evaluation of associated limb anomalies by plain radiographs. Contrast arthrography orMagnetic Resonance Imaging is indicated when radiological features are questionable and to disclose thepresence and location of the femoral head and any cartilagenous anlage. The disorder is more commonlyunilateral and is apparent at birth. However, bilateral involvement is rarely seen. Therapy of the disorder isdirected towards satisfactory ambulation and specific treatment depending on the severity of dysplasia.

  19. Tissue reaction around loosened prostheses: a histological, X-ray microanalytic and immunological study.

    Directory of Open Access Journals (Sweden)

    Hayashi,Takashi

    1986-10-01

    Full Text Available Tissue reactions at the cement-bone and artificial implant-bone interface were examined light and electron microscopically in thirty-six patients who underwent revisory operation of hip or knee replacement. The reactions were classified into three types: inert tissue, active tissue with giant cell proliferation, and active tissue with predominant foamy cell proliferation. The third type of reaction was found only in total hip replacement with bone cement. No evidence of allergic reaction to implanted materials was found in any replacement, though active cellular infiltrations were observed around loosened prostheses especially in cemented arthroplasty. The tissue reactions always occurred around instable or loosened prostheses. Thus, the present study shows that mechanical instability is the primary cause of such undesired tissue reactions.

  20. Do nit removal formulations and other treatments loosen head louse eggs and nits from hair?

    Science.gov (United States)

    Burgess, I F

    2010-03-01

    Eggs of the head louse, Pediculus capitis De Geer (Phthiraptera: Pediculidae), are difficult to remove because the female louse fixes them to hairs using a proteinaceous secretion that hardens within seconds. The persistent eggshells are harmless but unsightly and are often mistaken for an active infestation. Combing with a fine comb (nit comb) does not readily remove the eggs or empty eggshells because of the resilience of the fixative and both folk remedies and medical products have claimed to facilitate their removal. Measurement of the force required to initiate sliding of the egg fixative using a slip-peel tester was unable to detect evidence that any of three products which claimed to have egg-loosening properties (Step 2 Nit Removal System, Clear Lice Egg Remover, RID Lice Egg Loosener Gel) had any activity or exerted any effect on the egg fixative beyond the lubricating effects conveyed by water or conventional hair conditioner.

  1. Study on precision piezoelectric rotary step motors with inner anchor/loosen and outer drive

    Institute of Scientific and Technical Information of China (English)

    Jianfang LIU; Zhigang YANG; Ping ZENG; Zunqiang FAN

    2008-01-01

    A new precision rotary piezoelectric(PZT)actuator is proposed to improve its drive performance.Based on piezoelectric technology,the actuator adopts the principle of bionics,with a new method of stator inner anchor/loosen/rotor outer drive and a distortion structure of a thin shelf flexible hinge.This structure improves the stability of the anchor/loosen and step rotary.Its characteristics are evaluated by finite element analysis.The experiment shows that the new rotary PZT actuator works with higher frequency(40 Hz),higher speed (325 μrad/s),wider movement(360°),high resolution (1 μrad/step)and high torque(30 N·cm).The novel actuator can be applied in wide movement and high resolution driving devices such as those for optics engineering,precision positioning and some other micro-manipulation fields.

  2. Proximal Focal Femoral Deficiency

    OpenAIRE

    Vishal Kalia, Vibhuti

    2008-01-01

    Proximal focal femoral deficiency (PFFD) is a developmental disorder of the proximal segment of thefemur and of acetabulum resulting in shortening of the affected limb and impairment of the function. It isa spectrum of congenital osseous anomalies characterized by a deficiency in the structure of the proximalfemur. The diagnosis is often made by radiological evaluation which includes identification and descriptionof PFFD and evaluation of associated limb anomalies by plain radiographs. Contra...

  3. The potential application of a Cobalt Chrome Molybdenum femoral stem with functionally graded orthotropic structures manufactured using Laser Melting technologies.

    Science.gov (United States)

    Hazlehurst, K B; Wang, C J; Stanford, M

    2013-12-01

    The cementless fixation of porous coated femoral stems is a common technique employed for Total Hip Arthroplasty (THA). With the rate of revision surgery appearing to rise and younger more active patients requiring primary surgery it can be thought that alternative methods for increasing implant longevity need to be considered. The stress shielding of periprosthetic bone still remains a contributing factor to implant loosening, caused through a mismatch in stiffness between the implant and the bone. However, the ability to achieve stiffness matching characteristics is being realised through the use of Additive Layer Manufacturing (ALM) technologies and Functionally Graded Materials (FGM). This paper proposes an alternative design methodology for a monoblock Cobalt Chrome Molybdenum (CoCrMo) femoral stem. It hypothesises that a femoral stem suitable for cementless fixation can be manufactured using Laser Melting (LM) technology offering orthotropic functionally graded porous structures with similar mechanical properties to human bone. The structure and mechanical properties of the natural femur have been used as a basis for the design criteria which hypothesises that through a combination of numerical analysis and physical testing, an optimal design can be proposed to provide a lightweight, customised femoral stem that can reduce the risk of implant loosening through stress shielding whilst maintaining bone-implant interface stability.

  4. Densitometric evaluation might prevent failure of knee artroplasty for aseptic loosening

    OpenAIRE

    2016-01-01

    Objectives: To study the correlation between quantitative ultrasound (QUS) expressed as stiffness index (SI) and the risk of aseptic loosening of knee arthroplasty. Methods: An observational retrospective controlled study was performed on 85 female patients (mean age: 73.3 years) divided into 2 groups from January 2007 to March 2015 and carried out at the Orthopedic Rehabilitation Unit, Casa di Cura Eremo, Arco, Trento, Italy. Group A included 42 patients who had undergone a revision of knee ...

  5. Loosening and Sliding Behaviour of Bolt-Nut Fastener under Transverse Loading

    Directory of Open Access Journals (Sweden)

    Naruse T.

    2010-06-01

    Full Text Available The thread joint has been frequently used for the efficient productivity and maintainability as a machine element. However, many troubles such as loosening of bolted joints or fatigue failure of bolt were often experienced. Many attentions must be paid on the improvement of the strength and the reliability of the thread joints [1, 2]. It is generally said that the fastening axial force rapidly decreases by the rotation loosening of nuts if the relative slippage on the interfaces between nuts and fastened body goes beyond a certain critical limit [3]. This critical relative slippage (Scr that prescribes the upper limit for preventing the loosening behaviour has been estimated according to the theoretically obtained equation considering the bending deformation of bolt and the geometrical constraint condition. In this paper, firstly we present the equation for estimating the Scr based on the fundamental cantilever deformation model. Then we present the investigated results of the deformation behaviour of bolt-nut joint under transverse loading condition considering the reaction moment by nut (Mn. Finaly we can confirmed that these estimated results of critical relative slippage coincided well with the experimental results [4, 5].

  6. Stability Analysis for Loosened Rock Slope of Jinyang Grand Buddha in Taiyuan, China

    Science.gov (United States)

    SUN, Jinzhong; TIAN, Xiaofu; GUAN, Xudong; YU, Yonggui; YANG, Xiusheng

    On the basis of the status quo of Jinyang Grand Buddha in Taiyuan, some factors such as topography, geological structures, climate, hydrology, and engineering geology that influence the stability of the Buddha slope are considered, and several working situations of the slope that possibly suffered are presented in this article. The Buddha slope stands upright and the rock masses are composed of thick Permian sandstone, which dips slightly inward to the slope. Affected by both the incision of regional joints and the load relief to the free surface, the rock mass of the Buddha slope has turned into loosened blocks. Numerical stability analysis by FLAC-2D on the basis of the strength reduction method reveals that the localized deformation of the rock masses near the vertical surface of the slope may trigger reversing of rock beddings making the back dip slope convert into a dip slope with the possibility of plane sliding failure. Furthermore, the pseudostatic method for the dynamic process and limit equilibrium method for the static process are applied to different working situations of the Buddha slope. The analytical results illustrate that plane sliding failure will not occur when the slope is affected only by seism. However, water filling in the cracks of the loosened rock mass may greatly contribute to the potential plane sliding failure. When horizontal seism-force and hydrostatic pressure are coupled, the Buddha slope can hardly keep stable. Additionally, the loosened rock masses are prone to block toppling failure when influenced by the seism force.

  7. Prevascular femoral hernia and its relation with inferior epigastric vessels: a rare presentation of the femoral hernia sac.

    Science.gov (United States)

    Boshnaq, Mohamed; Phan, Yih Chyn; Akhtar, Mansoor; Hamade, Ayman

    2016-04-18

    A 61-year-old man presented to the emergency department, with a 2-week history of a painful lump on his right groin. A diagnosis of an irreducible right femoral hernia was made. As such, an urgent operation was carried out on the same day, and the patient was found to have a rare prevascular femoral hernia in which the sac was lying over the femoral vessels and split by the inferior epigastric vessels into 2 components resembling 2 trouser limbs. The hernia sac presented in a different and challenging way that necessitated meticulous dissection and full orientation of the anatomy of the femoral triangle. Complete dissection and control of the inferior epigastric vessels, and complete reduction of the sac followed by repair with a prosthetic mesh plug were performed successfully. The patient was discharged home the next day.

  8. Femoral pseudoaneurysms in drug addicts

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Rørdam, Peter; Jensen, L P

    1997-01-01

    OBJECTIVE: To evaluate the outcome of treatment of femoral pseudoaneurysms in drug addicts. METHODS: The records of eight patients undergoing vascular surgery for femoral pseudoaneurysms from substance abuse identified from a vascular database were reviewed. RESULTS: Were good in four out of five...

  9. Over-expression of p53/BAK in aseptic loosening after total hip replacement.

    Science.gov (United States)

    Landgraeber, Stefan; Toetsch, Martin; Wedemeyer, Christian; Saxler, Guido; Tsokos, Michael; von Knoch, Fabian; Neuhäuser, Markus; Löer, Franz; von Knoch, Marius

    2006-05-01

    Particle-induced osteolysis is a major cause of aseptic loosening after total joint replacement. The possible induction of apoptosis has not been addressed in great detail. Thus far, it has been shown that ceramic and polyethylene particles can induce apoptosis of macrophages in vitro. The purpose of this study was to test the hypothesis that wears debris generated from total hip arthroplasty could induce cellular damage and apoptosis in vivo. We therefore determined by immunohistochemical methods if increased expression of p53, an important transcription factor, and BAK and Bcl-2, two important regulators of apoptosis, can be found in interface membranes and capsules of hips with aseptically loose implants. Strongly positive immunohistochemical staining for p53 and BAK was found in peri-implant tissues from patients with aseptic hip implant loosening. Differentiation of various cell types showed that macrophages stained positive for p53 in all capsule and interface specimens. p53 was frequently detected in giant cells. Positive staining of BAK in macrophages and giant cells was seen in all specimens. Some positive reactions were observed in fibroblasts, only two of 19 cases stained for p53 and three cases for BAK within synovial cells. Positive macrophages and giant cells were localized around polyethylene particles. While T-lymphocytes showed a regular BAK-staining, the other leukocytes were negative. Statistical analyses showed significant positive correlations (p inductor of cell cycle arrest and apoptosis than metal debris. In this study apoptosis of macrophages, giant cells and T-lymphocytes in capsules and interface membranes of patients with aseptic hip implant loosening has been demonstrated in vivo. It is possible that the apoptotic cascade could evolve as a novel therapeutic target to prevent particle-induced osteolysis.

  10. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

    Directory of Open Access Journals (Sweden)

    M Erceg

    2014-01-01

    Full Text Available A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years.To the best of the author′s knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  11. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis.

    Science.gov (United States)

    Erceg, M; Becic, K

    2014-01-01

    A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author's knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  12. Simultaneous proximal femoral rotational and distal femoral varus osteotomies for femoral retroversion and genu valgum.

    Science.gov (United States)

    Wagner, Russell; Barcak, Eric A

    2012-04-01

    Whereas excess femoral anteversion and its related symptoms have been described many times, excess femoral retroversion is less well documented. We report the case of a 30-year-old woman who had a history of chronic bilateral hip and knee pain and evidence of excess femoral retroversion, genu valgum, early-onset lateral and patellofemoral compartment osteoarthritis of both knees, and hip arthritis. She experienced symptomatic relief after undergoing staged bilateral simultaneous proximal femoral rotational and distal femoral lateral opening wedge osteotomies. Although this combination of alignment problems is not an infrequent clinical occurrence, we have found no literature on this condition or treatment. The patient provided written informed consent for print and electronic publication of this case report.

  13. Distal femoral shortening in total hip arthroplasty for complex primary hip reconstruction. A new surgical technique.

    Science.gov (United States)

    Koulouvaris, Panagiotis; Stafylas, Kosmas; Sculco, Thomas; Xenakis, Theodore

    2008-10-01

    Successful total hip arthroplasty (THA) in congenital dislocated hips demands anatomical reduction in the normal center of rotation without overstretching the sciatic nerve and without excessive compression or abnormal forces across the joint. Proximal femoral and subtrochanteric shortening osteotomy has been described for THA for the treatment of dislocated hips. However, these osteotomies are demanding, associated with deformation of femoral canal and nonunion, and may increase the femoral stem stress. This study reports excellent results in 24 patients with a new surgical technique that combines THA with a distal femoral shortening in severely deformed hips using customized components.

  14. In vivo movement of femoral flexion axis of a single-radius total knee arthroplasty.

    Science.gov (United States)

    Shimizu, Norimasa; Tomita, Tetsuya; Yamazaki, Takaharu; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2014-12-01

    The objective of this study was to investigate in vivo femoro-tibial motion using the movement of femoral flexion axis of a single-radius TKA. We examined 20 clinically successful knees with a single-radius posterior stabilized TKA to evaluate the kinematics of deep knee flexion using 2-3-dimensional registration techniques. The mean knee flexion range of motion was 117.8°. The mean rotation of the femoral component was 7.6° external rotation. The mean knee flexion angle at initial post-cam engagement was 55.2°. No paradoxical movement of femoral component was shown until 70° flexion, afterward the femoral component rolled back with flexion. The data showed that the design of this prosthesis might contribute to reduce the paradoxical anterior femoral movement and provide stability in mid-flexion ranges.

  15. [Survival of the T28 femoral stem. Comparison of polished versus roughed-surface finish].

    Science.gov (United States)

    Chaidez Rosales, Pedro; Younger, Alastair; Renán León, Saúl; Poss, Robert

    2008-01-01

    Femoral stem loosening in total hip arthroplasty has a multifactorial etiology. T28 femoral stems have been made both roughed and polished-finish types, and differences in design are of interest in their effect on survival. One hundred and sixty-seven stems (84 polished and 83 roughed-finish) placed between 1975 and 1982 were evaluated. Gruen zones were used to determine loosening and survival was determined by the Kaplan-Meier method. Revision was made in 24.8% of the cases. Twenty-year survival rates were of 85.2% for roughed-finish stems and of 64.2% for polished-finish stems. We were able to confirm our hypothesis concerning the longer survival rate of the roughed-finish implant which was of 87.95% at 17 years of follow-up. The survival-time of the implant was independent of diagnosis, cementation, age and positioning. The survival-time of the T28 cemented implant does not only depend on its texture but it has a multifactorial origin.

  16. Proximal femoral replacement for the treatment of periprosthetic fractures.

    Science.gov (United States)

    Klein, Gregg R; Parvizi, Javad; Rapuri, Venkat; Wolf, Christopher F; Hozack, William J; Sharkey, Peter F; Purtill, James J

    2005-08-01

    A periprosthetic fracture around the femoral component is a rare but potentially problematic complication after total hip arthroplasty. Reconstruction can be challenging, especially when severe bone stock deficiency is encountered. Proximal femoral replacement is one method of treating the severely deficient proximal part of the femur. The present report describes the outcomes of revision total hip arthroplasty with use of a proximal femoral replacement in a cohort of patients who had a Vancouver type-B3 periprosthetic fracture. With use of a computerized institutional database, all patients in whom a Vancouver type-B3 fracture (characterized by severe proximal bone deficiency and a loose femoral stem) had been treated with a proximal femoral replacement were identified. A modular femoral replacement with proximal porous coating had been used in all cases. The twenty-one patients who were identified had had a mean age of 78.3 years (range, fifty-two to ninety years) at the time of the index operation. The clinical and radiographic records of these patients were reviewed. At the time of the latest follow-up (mean, 3.2 years), all but one of the patients were able to walk and had minimal to no pain. Complications included persistent wound drainage that was treated with incision and drainage (two hips), dislocation (two hips), refracture of the femur distal to the stem (one hip), and acetabular cage failure (one hip). Despite a relatively high complication rate, we believe that proximal femoral replacement is a viable option for the treatment of periprosthetic fractures in older patients with severe bone deficiency. If a proximal femoral replacement is used, the stability of the hip must be tested diligently intraoperatively and a constrained acetabular liner should be utilized if instability is encountered. In order to enhance the bone stock, the proximal part of the femur, however poor in quality, should be retained for reapproximation onto the implant.

  17. Focal femoral condyle resurfacing.

    LENUS (Irish Health Repository)

    Brennan, S A

    2013-03-01

    Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed. Cite this article: Bone Joint J 2013;95-B:301-4.

  18. The BCL2 -938C>A Promoter Polymorphism Is Associated with Risk for and Time to Aseptic Loosening of Total Hip Arthroplasty.

    Science.gov (United States)

    Stelmach, Patrick; Wedemeyer, Christian; Fuest, Lena; Kurscheid, Gina; Gehrke, Thorsten; Klenke, Stefanie; Jäger, Marcus; Kauther, Max D; Bachmann, Hagen S

    2016-01-01

    Aseptic loosening is a major cause of revision surgery of total hip arthroplasty (THA). Only few host factors affecting aseptic loosening have been identified until now, although they are urgently needed to identify and possibly treat those patients at higher risk for aseptic loosening. To determine whether the functional single nucleotide polymorphism (SNP) c.-938C>A (rs2279115), located in the promoter region of the BCL2 gene has an impact on aseptic loosening of THA we genotyped and analyzed 234 patients suffering from aseptic loosening and 231 patients after primary THA. The polymorphism is associated with risk for aseptic loosening with the CC genotype at highest risk for aseptic loosening, Odds Ratio CC vs. AA 1.93, 95%CI 1.15-3.25, p = 0.013. In contrast, low risk AA genotype carriers that still developed aseptic loosening showed a significantly shorter time to aseptic loosening than patients carrying the C allele (p = 0.004). These results indicate that the BCL2 -938C>A polymorphism influences the occurrence and course of aseptic loosening and suggests this polymorphism as an interesting candidate for prospective studies and analyses in THA registers.

  19. The BCL2 -938C>A Promoter Polymorphism Is Associated with Risk for and Time to Aseptic Loosening of Total Hip Arthroplasty.

    Directory of Open Access Journals (Sweden)

    Patrick Stelmach

    Full Text Available Aseptic loosening is a major cause of revision surgery of total hip arthroplasty (THA. Only few host factors affecting aseptic loosening have been identified until now, although they are urgently needed to identify and possibly treat those patients at higher risk for aseptic loosening. To determine whether the functional single nucleotide polymorphism (SNP c.-938C>A (rs2279115, located in the promoter region of the BCL2 gene has an impact on aseptic loosening of THA we genotyped and analyzed 234 patients suffering from aseptic loosening and 231 patients after primary THA. The polymorphism is associated with risk for aseptic loosening with the CC genotype at highest risk for aseptic loosening, Odds Ratio CC vs. AA 1.93, 95%CI 1.15-3.25, p = 0.013. In contrast, low risk AA genotype carriers that still developed aseptic loosening showed a significantly shorter time to aseptic loosening than patients carrying the C allele (p = 0.004. These results indicate that the BCL2 -938C>A polymorphism influences the occurrence and course of aseptic loosening and suggests this polymorphism as an interesting candidate for prospective studies and analyses in THA registers.

  20. Xyloglucan antibodies inhibit auxin-induced elongation and cell wall loosening of azuki bean epicotyls but not of oat coleoptiles.

    Science.gov (United States)

    Hoson, T; Masuda, Y; Sone, Y; Misaki, A

    1991-06-01

    Polyclonal antibodies were raised in rabbits against isoprimeverose (Xyl(1)Glc(1)), xyloglucan heptasaccharides (Xyl(3)Glc(4)), and octasaccharides (Gal(1)Xyl(3)Glc(4)). Antibodies specific for hepta- and octasaccharides suppressed auxin-induced elongation of epicotyl segments of azuki bean (Vigna angularis Ohwi and Ohashi cv Takara). These antibodies also inhibited auxin-induced cell wall loosening (decrease in the minimum stress-relaxation time and the relaxation rate of the cell walls) of azuki segments. However, none of the antibodies influenced auxin-induced elongation or cell wall loosening of coleoptile segments of oat (Avena sativa L. cv Victory). Auxin caused a decrease in molecular mass of xyloglucans in the cell walls of azuki epicotyls and oat coleoptiles. The antibodies inhibited such a change in molecular mass of xyloglucans in both species. Preimmune serum exhibited little or no inhibitory effect on auxin-induced elongation, cell wall loosening, or breakdown of xyloglucans. The results support the view that the breakdown of xyloglucans is associated with the cell wall loosening responsible for auxin-induced elongation in dicotyledons. The view does not appear to be applicable to poaceae, because the inhibition of xyloglucan breakdown by the antibodies did not influence auxin-induced elongation or cell wall loosening of oat coleoptiles.

  1. Percutaneous consolidation of loosened spine arthrodesis under CT and fluoroscopy guidance by radiologists: a new useful technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Bertrand, Anne-Sophie; Gallo, Giacomo; Caudal, Amandine; Boileau, Pascal [Centre Hospitalier Universitaire de Nice, Nice (France); Cornelis, Francois; Hauger, Olivier [Centre Hospitalier Universitaire de Bordeaux, Bordeaux (France)

    2015-04-01

    The objective was to evaluate percutaneous computed tomography (CT) and fluoroscopy-guided injection of bone cement for consolidation of loosened posterior arthrodesis performed by radiologists. A single-centre prospective study involving four consecutive patients (three women, one man) suffering from screw loosening (three at the vertebral level, one at the iliac wing level) after Posterior Lumbar Interbody Fusion (PLIF) treatment was done. The average age was 80 years. Surgical treatment was not indicated or not wished for by the patients. Institutional review board approval and informed consent were obtained. Percutaneous consolidation was performed by an interventional radiologist under CT and fluoroscopy guidance. The path of the trocars was made outside loosened screws bilaterally. Follow-up was assessed using the Visual Analog Scale (VAS). In all cases, bone cement was successfully placed around the loosened screw. The mean volume of cement that was injected was 3 ml. No cement leakage was observed. No neurological complication occurred. Using VAS, pain decreased from more than 9/10 preoperatively to less than 2/10 the day after the procedure for all patients (p < 0.05). This study suggests that loosening of spine arthrodesis could be successfully treated by percutaneous injection of bone cement under CT and fluoroscopy guidance. (orig.)

  2. Femoralni trikotnik: The femoral triangle:

    OpenAIRE

    Mlakar, Boštjan; Ravnik, Dean

    1999-01-01

    The topography and structures of the femoral triangle are presented. The femorai triangle lies between the inguinal ligament at the base, the sartoriusmuscle at the lateral border and the long adductor muscle at the medial border. The apex of the femoral triangle is situated at the meeting point of the medial borders of the sartorius and long adductor muscles. The subinguinal space, which is divided into the lacuna musculorum and lacuna vasorum, provides a passageway for the lateral cutaneous...

  3. Evaluation of a patient specific femoral alignment guide for hip resurfacing.

    Science.gov (United States)

    Olsen, Michael; Naudie, Douglas D; Edwards, Max R; Sellan, Michael E; McCalden, Richard W; Schemitsch, Emil H

    2014-03-01

    A novel alternative to conventional instrumentation for femoral component insertion in hip resurfacing is a patient specific, computed tomography based femoral alignment guide. A benchside study using cadaveric femora was performed comparing a custom alignment guide to conventional instrumentation and computer navigation. A clinical series of twenty-five hip resurfacings utilizing a custom alignment guide was conducted by three surgeons experienced in hip resurfacing. Using cadaveric femora, the custom guide was comparable to conventional instrumentation with computer navigation proving superior to both. Clinical femoral component alignment accuracy was 3.7° and measured within ± 5° of plan in 20 of 24 cases. Patient specific femoral alignment guides provide a satisfactory level of accuracy and may be a better alternative to conventional instrumentation for initial femoral guidewire placement in hip resurfacing.

  4. Loosen Couple Workflow Mode of Lean Operator Improvement Based on Positive Feedback

    Directory of Open Access Journals (Sweden)

    Yao Li

    2013-04-01

    Full Text Available In order to promote the core competitive power for telecom operating enterprises to face market fine operation, this article compares the ECTA mode (Extension Case Transmission Mode and the LCA mode (Loosen Couple Mode, both of which are promoted by WfMC. By comparing these two modes, the suitable situations for these two modes are determined. We also carry out empirical analysis based on the customization mode of mobile phones between China telecom and mobile phone manufacturers and to expound the ascension effect of mechanism based on the agile telecom loose coupling workflow with positive feedback to the telecom enterprises. Finally, on the basis of positive feedback system, the task complexity and information transparency of LCA mode are improved, so that the semantics of public flow mode is kept unchanged and the sub workflow is optimized when modifying the sub workflow.

  5. Comparison of the results between polyethylene liners articulated with zirconia ceramic and cobalt-chrome femoral heads in vivo

    Institute of Scientific and Technical Information of China (English)

    Feng Liu; James P. Waddell

    2005-01-01

    Objective: The aseptic loosening of the implants is the main contributor to the long-term failure of hip arthroplasty.One of the alternatives is to choose ceramic head instead of the traditional CoCr head. This study is conducted to determine the clinicalefficacy of a zirconia ceramic head. Methods: Twenty-six cementless total hip arthroplasties in 24 patients were performed using a zirconiahead coupled with polyethylene. All hips were followed for an average of 9 years (range, 6-13 years). A matched group of 26 hips in 26patients using cobalt-chrome heads coupled with polyethylene were also followed for average of 10 years (range, 5-14 years). The twogroups of patients were evaluated clinically and radiographically respectively. Results: The average scores of functional hip according toHarris standard improved from 46 (preoperatively) to 86 (at the final follow-up) in the Zirconia group, and from 50 to 88 in the CrCogroup. The mean liner wear rate of zirconia-polyethylene coupling was 0. 118 mm/year (range, 0. 064-0. 175 mm/year), and the linearwear rate of CrCo-polyethylene was 0.113 mm/year (range, 0.056-0.190 mm/year). There were 10 hips (27%) revised due to looseningor extensive osteolysis of the.cup in the Zirconia group, and only 4 hips (11.5%) in CrCo group. Conclusion: Results of the studysuggest that a zirconia ceramic femoral head has little advantage over a cobalt-chrome head in decreasing polyethylene wear in vivo. Ourstudy demonstrates that although changes in designs and materials may offer theoretical advantages over current components, their effectsremain questionable in vivo.

  6. Risk of dislocation using large- vs. small-diameter femoral heads in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Plate Johannes F

    2012-10-01

    Full Text Available Abstract Background Dislocation remains a difficult problem in total hip arthroplasty. Large-diameter femoral heads may lower the incidence of dislocation by enhancing the jump distance and decreasing impingement, but their performance against small-diameter heads has not been assessed. This study compared the mid-term radiographic and functional outcomes of two matched cohorts of patients undergoing total hip arthroplasty who had a high pre-operative risk for dislocation and who received either small-diameter (26- or 28-millimeters or large-diameter (≥36-millimeters femoral heads. Methods All patients who received large-diameter heads (≥36-millimeter between 2002 and 2005, and who had pre-operative risk factors for dislocation, were identified in the institution’s joint registry. Forty-one patients (52 hips who received large-diameter heads were identified, and these patients were matched to 48 patients (52 hips in the registry who received small-diameter femoral heads. Results At mean final follow-up of 62 months (range, 49 to 101 months, both groups achieved excellent functional outcomes as measured by Harris Hip scores, with slightly better final scores in the large-diameter group (90 vs. 83 points. No patient showed any radiographic signs of loosening. No patient dislocated in the large-diameter femoral head group; the smaller-diameter group had a greater rate of dislocation (3.8%, 2 out of 52. Conclusions Large-diameter femoral head articulations may reduce dislocation rates in patients who have a high pre-operative risk for dislocation while providing the same functional improvements and safety as small-diameter bearings.

  7. A Cannulated Tri-Tapered Femoral Stem for Total Hip Arthroplasty: Clinical and Radiological Results at Ten Years.

    Science.gov (United States)

    Rajakulendran, Karthig; Strambi, Francesco; Ruggeri, Riccardo; Field, Richard E

    2015-10-01

    We report the ten-year clinical and radiological outcomes of a novel cannulated, tri-tapered femoral stem, used in primary total hip arthroplasty (110 stems in 98 patients). At ten years, two Tri-taper stems had been revised for infection and dislocation. The mean Oxford Hip Score improved from 13.46 pre-operatively, to 37.04. Radiological analysis revealed radiolucent lines in 57 cases, but none exceeded 2 mm thickness. Stem subsidence was identified in 63 cases, with mean distal tip migration of 3.8 mm. Survivorship with revision for aseptic loosening as the end point was 100% at 10 years. Stem survival with revision for any cause was 98.2% (95% CI, 92.9% to 99.5%). The ten-year results of the Tri-taper stem are comparable to other polished, tapered femoral stems. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Long-term effects of deep soil loosening on root distribution and soil physical parameters in compacted lignite mine soils

    Science.gov (United States)

    Badorreck, Annika; Krümmelbein, Julia; Raab, Thomas

    2015-04-01

    Soil compaction is a major problem of soils on dumped mining substrates in Lusatia, Germany. Deep ripping and cultivation of deep rooting plant species are considered to be effective ways of agricultural recultivation. Six years after experiment start, we studied the effect of initial deep soil loosening (i.e. down to 65 cm) on root systems of rye (Secale cereale) and alfalfa (Medicago sativa) and on soil physical parameters. We conducted a soil monolith sampling for each treatment (deep loosened and unloosened) and for each plant species (in three replicates, respectively) to determine root diameter, length density and dry mass as well as soil bulk density. Further soil physical analysis comprised water retention, hydraulic conductivity and texture in three depths. The results showed different reactions of the root systems of rye and alfalfa six years after deep ripping. In the loosened soil the root biomass of the rye was lower in depths of 20-40 cm and the root biomass of alfalfa was also decreased in depths of 20-50 cm together with a lower root diameter for both plant species. Moreover, total and fine root length density was higher for alfalfa and vice versa for rye. The soil physical parameters such as bulk density showed fewer differences, despite a higher bulk density in 30-40cm for the deep loosened rye plot which indicates a more pronounced plough pan.

  9. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  10. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  11. Recurrent femoral hernia and associated ovarian pathology.

    Science.gov (United States)

    Gately, Ryan Patrick; Concannon, Elizabeth Sarah; Hogan, A; Ryan, R S; O'Leary, M; Barry, K

    2012-08-27

    The following case describes an ovarian tumour presenting in a highly unusual manner-in the form of a recurrent femoral hernia. Recurrent femoral herniae are unusual and should prompt awareness of underlying pathology causing increased intra-abdominal pressure.

  12. Transverse femoral implant prominence: four cases demonstrating a preventable complication for ACL reconstruction.

    Science.gov (United States)

    Argintar, Evan; Scherer, Benjamin; Jordan, Tom; Klimkiewicz, John

    2010-12-01

    Anterior cruciate ligament (ACL) tear is a commonly occurring injury that often demands surgical reconstruction. Although the utility of this operation is widely accepted, many specific components, including graft fixation technique, remain controversial. Many clinicians favor transverse femoral implant fixation for soft tissue ACL grafts. This technique can be accomplished successfully; however, in a minority of the cases, the femoral implant can be excessively prominent, leading to iatrogenic postoperative iliotibial band syndrome. This article presents 4 patients that developed postoperative iliotibial band syndrome resulting from transverse femoral implant prominence. Despite achievement of knee ligamentous stability, implant prominence compromised final clinical results following ACL reconstruction. Through change in Lysholm value, we reviewed the clinical outcomes of these patients following femoral implant hardware removal for treatment of iliotibial band syndrome. On hardware removal, all patients demonstrated complete symptomatic improvement, mirroring an average Lysholm value increase of 38. We believe transverse femoral implant prominence is avoidable, and subsequent iliotibial band syndrome is a preventable postoperative complication.

  13. Effect of simulated early weight bearing on micromotion and pullout strength of uncemented distal femoral stems.

    Science.gov (United States)

    Barr, Jennifer S; White, Jedediah K; Punt, Stephanie E W; Conrad, Ernest U; Ching, Randal P

    2015-05-01

    The effect of simulated early weight bearing on both micromotion and pullout strength of uncemented distal femoral stems was evaluated in this study. The effect of stem endosteal contact and bone quality on implant pullout strength was also analyzed. A randomized matched-pair study was performed using 8 bilateral pairs of fresh human cadaveric femoral specimens. Each specimen pair was dual-energy x-ray absorptiometry scanned, uniformly implanted, fluoroscopically imaged, and randomly assigned to the cycled or uncycled group. The cycled group received 5000 cycles of axial compressive loading (to 700 N) and the contralateral side was not cycled. Micromotion was monitored during cycling and compared with a failure threshold (150 µm), and all implants underwent direct axial distraction (pullout) testing. During cycling, minimal micromotion was observed with an asymptotic decrease in differential motion between the first and last 50 cycles. Both cycled and uncycled groups demonstrated no statistical difference in average pullout force (4888±2124 N vs 4367±1154 N; P=.43). The percentage of cortical contact for each implant was determined from panoramic fluoroscopy images using digital image analysis software. Contact area for the distal third of the stem showed the highest correlation with pullout force and with predicting pullout force. Bone quality did not correlate with pullout force (r(2)=0.367) or stem contact area (r(2)=0.394). In sum, press-fit uncemented femoral stems did not loosen or demonstrate decreased pullout strength with early weight bearing simulated by cyclical axial compressive loading.

  14. Periprosthetic femoral bone loss in total hip arthroplasty: systematic analysis of the effect of stem design.

    Science.gov (United States)

    Knutsen, Ashleen R; Lau, Nicole; Longjohn, Donald B; Ebramzadeh, Edward; Sangiorgio, Sophia N

    2017-02-21

    Periprosthetic bone loss may lead to major complications in total hip arthroplasty (THA), including loosening, migration, and even fracture. This study analysed the influence of femoral implant designs on periprosthetic bone mineral density (BMD) after THA. The results of all previous published studies reporting periprosthetic femoral BMD following THA were compiled. Using these results, we compared percent changes in bone loss as a function of: femoral stem fixation, material, and geometry. The greatest bone loss was in the calcar region (Gruen Zone 7). Overall, cemented stems had more bone loss distally than noncemented stems, while noncemented stems had more proximal bone loss than cemented stems. Within noncemented stems, cobalt-chromium (CoCr) stems had nearly double the proximal bone loss compared to titanium (Ti) alloy stems. Finally, within noncemented titanium alloy group, straight stems had less bone loss than anatomical, tapered, and press-fit designs. The findings from the present study quantified percent changes in periprosthetic BMD as a function of fixation method, alloy, and stem design. While no one stem type was identified as ideal, we now have a clearer understanding of the influence of stem design on load transfer to the surrounding bone.

  15. Total hip arthroplasty using TRI-LOCK® DePuy bone preservation femoral stem: our experience.

    Science.gov (United States)

    Sperati, G; Ceri, L

    2014-09-24

    In this study we report our 3-years experience (from January 2010 to December 2013) of 101 total hip arthroplasties using Tri-Lock® DePuy bone preservation femoral stem, all performed in our clinic. 101 patients (F54-M47; median age around 69 yrs, range 42-84 yrs). 51 arthroplasties were implanted on the right side whereas 50 on the left side. The average follow-up was 27,3 months. All the arthroplasties were coupled with Pinnacle® polyethylene acetabular cup system; 98 prostheses were implanted cementless whereas cement was used in 3 cases. The Tri-Lock® femoral stem allows both soft tissues and bone stock preservation, leading to greater trochanter maintenance, less spongy bone removal and distal cavity bone tissue conservation. In our experience, we were able to implant the Tri-Lock® femoral stem even in osteoporotic and overweight patients using Gription® porous coating. This allowed for commencing an intensive rehabilitation program with stable load from the following day, without observing any early complications or loosening. According to us, this device is solid and safe, providing remarkable sparing of both soft tissues and bone stock.

  16. Assessment of femoral bone quality using co-occurrence matrices and adaptive regions of interest

    Science.gov (United States)

    Fritscher, Karl David; Schuler, Benedikt; Grünerbl, Agnes; Hänni, Markus; Schwieger, Karsten; Suhm, Norbert; Schubert, Rainer

    2007-03-01

    The surgical treatment of femur fractures, which often result from osteoporosis, is highly dependent on the quality of the femoral bone. Unsatisfying results of surgical interventions like early loosening of implants may be one result of altered bone quality. However, clinical diagnostic techniques to quantify local bone quality are limited and often highly observer dependent. Therefore, the development of tools, which automatically and reproducibly place regions of interest (ROI) and asses the local quality of the femoral bone in these ROIs would be of great help for clinicians. For this purpose, a method to position and deform ROIs automatically and reproducibly depending on the size and shape of the femur will be presented. Moreover, an approach to asses the femur quality, which is based on calculating texture features using co-occurrence matrices and these adaptive regions, will be proposed. For testing purposes, 15 CT-datasets of anatomical specimen of human femora are used. The correlation between the texture features and biomechanical properties of the proximal femoral bone is calculated. First results are very promising and show high correlation between the calculated features and biomechanical properties. Testing the method on a larger data pool and refining the algorithms to further increase its sensitivity for altered bone quality will be the next steps in this project.

  17. Femoral hernia; Clinical significance of radiologic diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Bergenfeldt, M.; Lasson, A. (Lund University (Sweden). Department of Surgery Malmo General Hospital (Sweden)); Ekberg, O.; Kesek, P. (Lund University (Sweden). Department of Radiology Malmo General Hospital (Sweden))

    A retrospective study of 18 patients with femoral hernia assessed by herniography is presented. Although a palpable lump was present in 11 patients (61%), the diagnosis of a femoral hernia was not made before herniography. Surgical exploration was performed in 12 patients and a femoral hernia was found and repaired with beneficial outcome in 9 of them. In conclusion: herniography is of value for the diagnosis of a femoral hernia in patients with obscure groin pain. (author). 14 refs.; 2 figs.

  18. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications].

    Science.gov (United States)

    Pavelka, T; Salášek, M; Weisová, D

    2017-01-01

    PURPOSE OF THE STUDY The study consists of a retroactive evaluation of results of surgical treatment in patients with periprosthetic femoral fracture after total hip replacement and a comparison with results reported in the literature. MATERIAL AND METHODS In the period from 2003 to 2013, a total of 83 patients with periprosthetic femoral fracture after total hip replacement were treated at our clinic, namely 69 women and 14 men. The mean age in the cohort was 74 years (range 47-87). The Vancouver classification was used to grade the fractures. The cohort included 31 patients with type B1 fracture, 25 patients with type B2 fracture, 8 patients with type B3 fracture, and 19 patients with type C fracture. Altogether 80 patients underwent a surgery, 3 patients with non-displaced type B1 fracture were treated conservatively. The mechanism of injury was a simple fall in 75 % of primary endoprostheses and in 56% of revision endoprostheses. The average time to fracture was 7.6 years in primary implant and 3.6 years in revision endoprosthesis. In fractures with a well-fixed stem (type B1 and C) plate osteosynthesis was used. In case of a comminution zone, osteosynthesis was followed by spongioplasty. In patients with a loose stem (type B2 and B3), the fracture was treated with a revision uncemented stem. In two cases a combination of a revision stem and a massive corticocancellous bone graft was used. The evaluation was performed using the Harris Hip Score and the minimum follow-up from the surgery was 3 years. RESULTS In the group of patients with type B1 fracture, 28 patients were treated surgically. An excellent result was achieved in 22 patients (84%), in 4 patients (16%) the result was very good. The remaining 2 patients failed to meet the requirement of the minimum follow-up of 3 years. In the group of patients with type B2 fractures, composed of 25 patients, the femoral component was replaced with a revision uncemented stem with cerclage wires or titanium tapes or

  19. Femoral Reconstruction Using External Fixation

    Directory of Open Access Journals (Sweden)

    Yevgeniy Palatnik

    2011-01-01

    Full Text Available Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD, limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD and lateral distal femoral angle (LDFA for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction.

  20. Wear resistance of the biocompatible phospholipid polymer-grafted highly cross-linked polyethylene liner against larger femoral head.

    Science.gov (United States)

    Moro, Toru; Takatori, Yoshio; Kyomoto, Masayuki; Ishihara, Kazuhiko; Kawaguchi, Hiroshi; Hashimoto, Masami; Tanaka, Takeyuki; Oshima, Hirofumi; Tanaka, Sakae

    2015-07-01

    The use of larger femoral heads to prevent the dislocation of artificial hip joints has recently become more common. However, concerns about the subsequent use of thinner polyethylene liners and their effects on wear rate have arisen. Previously, we prepared and evaluated the biological and mechanical effects of a novel highly cross-linked polyethylene (CLPE) liner with a nanometer-scaled graft layer of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC). Our findings showed that the PMPC-grafted particles were biologically inert and caused no subsequent bone resorptive responses and that the PMPC-grafting markedly decreased wear in a hip joint simulator. However, the metal or ceramic femoral heads used in this previous study had a diameter of 26 mm. Here, we investigated the wear-resistance of the PMPC-grafted CLPE liner with a 40-mm femoral head during 10 × 10(6) cycles of loading in the hip joint simulator. The results provide preliminary evidence that the grafting markedly decreased gravimetric wear rate and the volume of wear particles, even when coupled with larger femoral heads. Thus, we believe the PMPC-grafting will prolong artificial hip joint longevity both by preventing aseptic loosening and by improving the stability of articular surface.

  1. Sustained Release of Vancomycin from Polyurethane Scaffolds Inhibits Infection of Bone Wounds in a Rat Femoral Segmental Defect Model

    Science.gov (United States)

    2010-04-09

    a one shot two component reaction between the triisocyanate and the hardener comprising polyester triol, water, TEGOAMIN33 tertiary amine catalyst ...Sustained release of vancomycin from polyurethane scaffolds inhibits infection of bone wounds in a rat femoral segmental defect model Bing Li a,b...2010 Keywords: Polyurethane Vancomycin Sustained release Infection control Rat femoral segmental defect Bone tissue engineering Infection is a common

  2. [Medium-term effectiveness of total hip arthroplasty with straight tapered rectangular femoral prosthesis].

    Science.gov (United States)

    Liu, Hongwei; Gu, Weidong; Sun, Junying

    2013-05-01

    To investigate the medium-term effectiveness of straight tapered rectangular femoral prosthesis in total hip arthroplasty (THA). Between May 2004 and June 2006, 58 cases (61 hips) of hip joint disease underwent THA with straight tapered rectangular femoral prosthesis and the clinical data of 43 cases (45 hips) followed up more than 6 years were retrospectively analyzed. There were 21 males (23 hips) and 22 females (22 hips) with an average age of 51.6 years (range, 25-75 years), including 12 cases (12 hips) of congenital developmental dysplasia of the hip, 1 case (1 hip) of osteoarthritis secondary to acetabular dysplasia, 1 case (1 hip) of hip deformity after poliomyelitis, 9 cases (9 hips) of femoral neck fractures, 8 cases (8 hips) of avascular necrosis of the femoral head, 8 cases (8 hips) of osteoarthritis of the hip joint, 2 cases (3 hips) of rheumatoid arthritis, and 2 cases (3 hips) of ankylosing spondylitis. Unilateral replacement was performed in 41 cases and bilateral replacement in 2 cases. The Harris score was 41.7 +/-10.4 before operation. X-ray examination was performed to analyze the location of femoral prostheses and evaluate the stability of the prosthesis-bone interface, and Harris score was used to evaluate the hip function. Periprosthetic fracture occurred in 3 hips, and thigh pain in 4 hips after operation. Forty-three cases (45 hips) were followed up 74-99 months (mean, 85 months). Harris score was 87.6 +/- 8.3 at last follow-up, showing significant difference when compared with preoperative score (t=23.14, P=0.00). The X-ray examination showed that 9 hips had heterotopic ossification; bone resorption caused by stress shielding was observed at the proximal femur in 42 hips. But the stability of the prosthesis-bone interface was good; no infection or dislocation occurred; and no revision for aseptic loosening was performed in all cases. The survival rate of the femoral prosthesis was 100% during medium-term follow-up. THA with straight tapered

  3. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation.

    Science.gov (United States)

    Kang, K-T; Koh, Y-G; Son, J; Kwon, O-R; Baek, C; Jung, S H; Park, K K

    2016-11-01

    Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems.Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552-559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. © 2016 Kang et al.

  4. Use of next generation sequencing to detect biofilm bacteria in a patient with pedicle screw loosening after spine surgery

    DEFF Research Database (Denmark)

    Xu, Yijuan; Thomsen, Trine Rolighed; Lorenzen, Jan

    2016-01-01

    2. Center for Microbial Communities, Department of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Denmark 3. Otto-von-Guericke University Magdeburg, Department of Orthopedic Surgery, Magdeburg, Germany 4. Eifelklinik St. Brigida, Simmerath, Germany Aim: ”Hidden deep...... as a possible cause for implant loosening. This case report describes the use of NGS in the diagnostic work-up of a patient with pedicle screw loosening after spine surgery.” Method: ”A 60 y/o male had to undergo revision spine surgery for pedicle screw loosening and adjacent segment disease 3 years after...... identified by MALDI-TOF . For the molecular detection, DNA was extracted using MolYsis complete5 (Molzym, Germany). The V1-3 region of 16S rRNA gene was PCR-amplified with bacterial primers 27F and 534R (30 cycles) and paired-end sequenced on Miseq DNA sequencer (v3 chemistry, 2×300 bp). Paired-end reads...

  5. Quality of life in old patients with proximal femoral fractures

    Directory of Open Access Journals (Sweden)

    T A Raskina

    2012-01-01

    Full Text Available Objective: to study quality of life in Kemerovo old patients with proximal femoral fractures. Patients and methods. Quality of life in osteoporotic fractures was analyzed in 219 patients (173 women and 46 men who had sustained the injury in January 2004 to December 2008. Results. In the patients with hip fractures, the lowest (41.94+31.16 scores values were recorded by the physical functioning scale reflecting the degree to which their health limited the performance of physical exercises (self-service, walking, going upstairs, weight carriage, etc.. The role functioning and life activity scales showed the highest values (50.96+19.04 and 51.44+26.51 scores, respectively. The mean value of the physical component scale was 46.42+28.26 scores. That of the psychological component scale was 49.56+19.55 scores. Conclusion. The patients with proximal femoral fractures were found to have lower scores on all SF-36 dimensions.

  6. Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: comparisons with the effect of polyethylene cross-linking and ceramic femoral heads.

    Science.gov (United States)

    Moro, Toru; Kawaguchi, Hiroshi; Ishihara, Kazuhiko; Kyomoto, Masayuki; Karita, Tatsuro; Ito, Hideya; Nakamura, Kozo; Takatori, Yoshio

    2009-06-01

    Aseptic loosening of artificial hip joints induced by wear particles from the polyethylene (PE) liner remains the ruinous problem limiting their longevity. We reported here that grafting with a polymer, poly(2-methacryloyloxyethyl phosphorylcholine (MPC)) (PMPC), on the PE liner surface dramatically decreased the wear production under a hip joint simulator condition. We examined that the effect of properties of both PE by cross-linking and femoral head by changing the materials on wearing properties of PE. The PMPC grafting on the liners increased hydrophilicity and decreased friction torque, regardless of the cross-linking of the PE liner or the difference in the femoral head materials. During the hip joint simulator experiments (5 x 10(6) cycles of loading), cross-linking caused a decrease of wear amount and a reduction of the particle size, while the femoral head materials did not affect it. The PMPC grafting abrogated the wear production, confirmed by almost no wear of the liner surface, independently of the liner cross-linking or the femoral head material. We concluded that the PMPC grafting on the PE liner surpasses the liner cross-linking or the change of femoral head materials for extending longevity of artificial hip joints.

  7. Hip resurfacing femoral neck fracture influenced by valgus placement.

    Science.gov (United States)

    Anglin, Carolyn; Masri, Bassam A; Tonetti, Jérôme; Hodgson, Antony J; Greidanus, Nelson V

    2007-12-01

    Femoral neck fracture is the most common short-term concern after hip resurfacing arthroplasty. Currently, there is little basis to decide between neutral and valgus placement. We loaded 10 notched cadaveric femur pairs to failure; one side was implanted at 0 degrees relative to the femoral neck and the other at 10 degrees valgus. All 20 were dual-energy X-ray absorptiometry-scanned. Failure load correlated with bone mineral density. Valgus placement increased the fracture load by an average of 28% over neutral for specimens with normal bone mineral density but had no effect on fracture load in specimens with low bone mineral density. For specimens with normal bone mineral density (typical of patients undergoing resurfacing arthroplasty), neutral-valgus placement had a greater effect than bone mineral density, explaining 54% of the fracture load variance. Component placement greater than 10 degrees valgus is likely undesirable because this can lead to an increase in component size and a greater likelihood of notching. To reduce fracture risk, we recommend placing the femoral component in valgus and selecting patients with higher bone mineral density.

  8. Application of proximal femoral shaft splitting at sagittal view in total hip arthroplasty%股骨近段矢状位纵向劈开成形在全髋置换中的应用

    Institute of Scientific and Technical Information of China (English)

    李永旺; 孙俊英; 杨立文; 骆圆; 杨茂伟

    2011-01-01

    Objective To summarize the clinical result of the proximal femoral shaft splitting at sagittal view in primary total hip arthroplasty (THA) in treatment of ultimate hip disease combined with femoral metaphyseal stenosis deformity. Methods A retrospective study was done on 18 patients with proximal femoral deformity (22 hips including 14 patients with unilateral hips and 4 with bilateral hips)treated from January 2000 to December 2009.There were three males and 15 females, at age range of 41-75 years (average 54 years).According to Berry classification system, all patients were indentified as metaphyseal segment abnormality and deformity, including developmental type disease (congenital hip dysplasia) in 17 patients and old tuberculosis of the hip in one.The congenital hip dysplasia was diagnosed as type Ⅳ by using the Crowe classification system.All the patients were treated with the proximal femoral shaft splitting, subtrochanteric shortening with overlapping femoral resection and V-shaped derotational osteotomy.In the meantime, standard biological fixation of the femoral stem prosthesis was performed. Results There found no dislocation, infection, lower extremity nerve stretch injury or uncontrolled proximal femur fractures.X-ray showed that all acetabular cups were placed at the anatomical position and that the initial femoral stem prosthesis fixation was rated as good.All osteotomy areas were healed within 3-6 months.Limb length discrepancy was restored to average 3 cm after surgery.The patients were followed up for 1-10 years (average six years), which showed that the average Harris hip score was improved from preoperative 30 to postoperative 93, with no aseptic loosening or osteolysis or radiolucent line around the femoral component, no prosthesis sinking or varus displacement, or no patients needing revision of the femoral component.Conclusions The proximal femoral shaft splitting at sagittal view and standard biological fixation of the femoral stem

  9. Risk of femoral hernia after inguinal herniorrhaphy

    DEFF Research Database (Denmark)

    Mikkelsen, T; Bay-Nielsen, M; Kehlet, H

    2002-01-01

    BACKGROUND: Small case series have suggested an increased risk of femoral hernia after previous inguinal herniorrhaphy, but no large-scale data with complete follow-up are available. METHODS: Data were extracted from the Danish Hernia Database covering the interval from 1 January 1998 to 1 July...... 2001, and included 34 849 groin hernia repairs. RESULTS: Of 1297 femoral hernia repairs, 71 patients had previously had an operation for inguinal hernia within the observation period. These 71 femoral hernias represented 7.9 per cent of all reoperations for groin hernia recorded in the database....... The median time to reoperation for a 'recurrent' femoral hernia after previous inguinal herniorrhaphy was 7 months, compared with 10 months for inguinal recurrences. The risk of developing a 'recurrent' femoral hernia after previous inguinal herniorrhaphy was 15 times higher than the rate of femoral hernia...

  10. Risk of femoral hernia after inguinal herniorrhaphy

    DEFF Research Database (Denmark)

    Mikkelsen, T; Bay-Nielsen, M; Kehlet, H

    2002-01-01

    BACKGROUND: Small case series have suggested an increased risk of femoral hernia after previous inguinal herniorrhaphy, but no large-scale data with complete follow-up are available. METHODS: Data were extracted from the Danish Hernia Database covering the interval from 1 January 1998 to 1 July...... 2001, and included 34 849 groin hernia repairs. RESULTS: Of 1297 femoral hernia repairs, 71 patients had previously had an operation for inguinal hernia within the observation period. These 71 femoral hernias represented 7.9 per cent of all reoperations for groin hernia recorded in the database....... The median time to reoperation for a 'recurrent' femoral hernia after previous inguinal herniorrhaphy was 7 months, compared with 10 months for inguinal recurrences. The risk of developing a 'recurrent' femoral hernia after previous inguinal herniorrhaphy was 15 times higher than the rate of femoral hernia...

  11. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements

    DEFF Research Database (Denmark)

    Miles, James Edward

    2016-01-01

    Objective: To describe the effects of internal and external femoral rotation on radiographic measurements of the anatomical lateral distal femoral angle (a-LDFA) using two methods for defining the anatomical proximal femoral axis (a-PFA). Methods: Digital radiographs were obtained of 14 right fem...

  12. The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures.

    Science.gov (United States)

    Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Adams, Joanne B; Russell, Jackie H; Groseth, Kari L

    2005-10-01

    Constrained acetabular components can treat or prevent instability after total hip arthroplasty (THA). We examine long-term results of 755 consecutive constrained THA in 720 patients (1986-1993; 62 primary, 59 conversion, 565 revision, 60 reimplantation, and 9 total femur). Eighty-three patients (88 THAs) were lost before 10-year follow-up, leaving 639 patients (667 THAs) available for study. Dislocation occurred in 117 hips (17.5%), in 37 (28.9%) of 128 constrained for recurrent dislocation, and 46 (28.2%) of 163 with dislocation history. Other reoperations were for aseptic loosening (51, 7.6% acetabular; 28, 4.2% stem; 16, 2.4% combined), infection (40, 6.0%), periprosthetic fracture (19, 2.8%), stem breakage (2, 0.3%), cup malposition (1, 0.1%), dissociated insert (1, 0.1%), dissociated femoral head (1, 0.1%), and impingement of 1 broken (0.1%) and 4 (0.6%) dissociated constraining rings. Although constrained acetabular components prevented recurrent dislocation in 71.1%, they should be used cautiously, with a 42.1% long-term failure rate observed in this series. Dislocation was common despite constraint with previous history as a significant risk.

  13. Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis

    Institute of Scientific and Technical Information of China (English)

    Zhao Wenbo; Liu Lei

    2014-01-01

    Objective:To discuss the curative effect of the dynamic hip system blade (DHS-blade) on the treatment of femoral neck fractures in elderly patients with osteoporosis.Methods:A retrospective study was conducted to analyse the clinical data of 60 elderly patients with osteoporosis who had been treated for femoral neck fractures with DHS-blade in our department between September 2012 and February 2014.There were 22 males and 38 females with a mean age of (66.8±3.2) years.According to the Singh Index Classification,all the patients' Singh index was below level 3.The Harris criterion and function recovery after operation were analysed.Results:All patients were followed up for 12-17 months (mean 14 months).No femoral head necrosis,femoral neck shortening,internal fixation loosening or backing out of the nails occurred.Bone nonunion was found in one case and he had a good recovery after total hip arthroplasty.The time for fracture healing ranged from 3-6 months (average 3.5 months).According to Harris criterion,35 cases were rated as excellent,22 good,2 fair and 1 poor.The Harris scale was significantly improved from 28.46±2.35 preoperatively to 91.98±3.26 at 6 months postoperatively (P<0.05).Conclusion:DHS-blade,being minimally invasive,allowing earlier postoperative exercise and avoiding the complications elicited by traditional internal fixation,is advisable for treatment of femoral neck fractured patients with osteoporosis.

  14. Trochanter/calcar preserving reconstruction in tumors involving the femoral head and neck

    Science.gov (United States)

    Cho, Hwan Seong; Lee, Young-Kyun; Ha, Yong-Chan; Koo, Kyung-Hoi

    2016-01-01

    AIM: To evaluate the results of hip reconstruction with extensive excision for tumor confined to the femoral head and neck. METHODS: We designed a resection preserving the greater trochanter and lower portion of calcar femorale, and utilized conventional total hip prosthesis. We retrospectively reviewed 7 patients, who underwent a wide resection and reconstruction using conventional hip prosthesis. There were 3 men and 4 women and their mean age was 42.5 years (22 to 65 years). The histologic diagnosis of each patient was low-grade osteosarcoma, diffuse large B-cell lymphoma, liposclerosing myxofibroma, intraosseous lipoma, chondroblastoma, giant cell tumor and focal intramedullary fibrosis. RESULTS: One patient with lymphoma died due to disease dissemination at 10 mo postoperatively and the remaining 6 patients were followed for a mean of 4.7 years (3 to 6 years). All patients were able to return to their daily activities and no patient had local recurrence. No radiographic signs of loosening, wear, and osteolysis were found at the last follow-up. CONCLUSION: Trochanter/calcar-preserving resection of the proximal femur and reconstruction using conventional total hip prosthesis, is a satisfactory treatment for tumors confined to the femoral head and neck. PMID:27458555

  15. Osteonecrosis of Femoral Head Occurred after Stent Placement of Femoral Artery

    Directory of Open Access Journals (Sweden)

    Akiyoshi Shimatani

    2014-01-01

    Full Text Available We present a case of osteonecrosis of femoral head (ONFH that occurred after stent angiography of femoral artery for the treatment of arteriosclerosis obliterans (ASO of left inferior limb in a 76-year-old woman. No case of late collapse of femoral head as a complication of endovascular procedure such as stent placement has been previously documented. We considered that ONFH occurred after detaining stent at a junction of left deep femoral artery for the treatment of the ischemia of left lateral and medial femoral circumflex artery.

  16. Osteonecrosis of the femoral head: diagnosis and classification systems

    National Research Council Canada - National Science Library

    Choi, Ho-Rim; Steinberg, Marvin E; Y. Cheng, Edward

    2015-01-01

    Osteonecrosis of femoral head is a rare but disabling condition that usually results in progressive femoral head collapse and secondary arthritis necessitating total hip arthroplasty if not treated...

  17. Classification of subtrochanteric femoral fractures.

    Science.gov (United States)

    Loizou, C L; McNamara, I; Ahmed, K; Pryor, G A; Parker, M J

    2010-07-01

    A review of the literature identified 15 different classification methods for subtrochanteric femoral fractures. Only eight of those classifications defined the area of bone, which constituted a subtrochanteric fracture. The actual length of femur defined as the subtrochanteric zone varied from 3 cm up to the level of the femoral isthmus. There was no agreement between the different classifications regarding the proximal and distal border or for those fractures, which traverse anatomical boundaries. In the various classifications, fractures were subdivided into 2-15 subgroups. The majority of the identified studies were unable to find the classifications useful in either determining treatment or predicting the outcome after treatment. We subdivided subtrochanteric fractures into three types based on the degree of fracture comminution. We examined the inter- and intra-observer agreement of our recommended classification. One orthopaedic consultant, one specialist hip fracture surgeon, two trainee registrar orthopaedic surgeons and one specialty trainee in orthopaedics, on two different occasions, 8 weeks apart, independently classified the radiographs of 20 patients with a subtrochanteric fracture. The mean kappa value for inter- and intra-observer variation was 0.71 and 0.79, respectively, with both showing substantial agreement and, therefore, this simpler classification is recommended. Based on the review of previous classification methods, we also recommend that the subtrochanteric zone be defined as the one in which the fracture line crossing the femur is predominantly within the area of bone extending 5 cm below the lower border of the lesser trochanter.

  18. Relaxation response in femoral angiography.

    Science.gov (United States)

    Mandle, C L; Domar, A D; Harrington, D P; Leserman, J; Bozadjian, E M; Friedman, R; Benson, H

    1990-03-01

    Immediately before they underwent femoral angiography, 45 patients were given one of three types of audiotapes: a relaxation response tape recorded for this study, a tape of contemporary instrumental music, or a blank tape. All patients were instructed to listen to their audiotape during the entire angiographic procedure. Each audiotape was played through earphones. Radiologists were not told the group assignment or tape contents. The patients given the audiotape with instructions to elicit the relaxation response (n = 15) experienced significantly less anxiety (P less than .05) and pain (P less than .001) during the procedure, were observed by radiology nurses to exhibit significantly less pain (P less than .001) and anxiety (P less than .001), and requested significantly less fentanyl citrate (P less than .01) and diazepam (P less than .01) than patients given either the music (n = 14) or the blank (n = 16) control audiotapes. Elicitation of the relaxation response is a simple, inexpensive, efficacious, and practical method to reduce pain, anxiety, and medication during femoral angiography and may be useful in other invasive procedures.

  19. Incarcerated Femoral Hernia Containing Ipsilateral Fallopian Tube

    Directory of Open Access Journals (Sweden)

    Stefanos Atmatzidis

    2010-01-01

    Full Text Available Femoral hernias are more common in women and lead to a substantial higher rate for an emergency operation, due to strangulation. Incarcerated femoral hernia with fallopian tube as a content is an extremely rare condition. A 20-year-old woman presented to the emergency department complaining of a 6-day right groin swelling, which became painful and tender to palpation during the last 48 hours. Preoperative ultrasonography detected an oedematous hernia sac, above the femoral vessels, suggesting the presence of an incarcerated femoral hernia. The patient eventually underwent emergency surgery and the diagnosis of a strangulated femoral hernia sac, containing fallopian tube, was established. No resection of the uterine tube was performed and the hernia was repaired with polypropylene plug. The postoperative period was uneventful and the woman was discharged on the second postoperative day.

  20. [ANATOMICAL PLATE COMBINED WITH CORTICAL BONE PLATE ALLOGRAFTS FOR TREATMENT OF COMMINUTED FRACTURES OF FEMORAL CONDYLES].

    Science.gov (United States)

    Guo, Zhimin; Gong, Xingxing; Li, Yanwei; Qiu, Xiaochun; Zhang, Meng; Shangguan, Tiancheng; Ao, Qingfang; Liu, Qiang

    2015-01-01

    To summarize the effectiveness of anatomical plate combined with cortical bone plate allografts in the treatment of comminuted fractures of the femoral condyles. Between January 2008 and December 2012, 18 patients with comminuted fractures of the femoral condyles were treated, including 13 males and 5 females with an average age of 45 years (range, 23-65 years). Fractures were caused by traffic accident in 11 cases, by falling from height in 4 cases, and by the other in 3 cases. The locations were the left side in 7 cases and the right side in 11 cases. Of 18 fractures, 12 were open fractures and 6 were closed fractures. The mean time from injury to operation was 6 days (range, 4-15 days). The fixation was performed by anatomical plate combined with cortical bone plate allografts, and autograft bone or allogeneic bone grafting were used. Superficial local skin necrosis occurred in 1 case, and was cured after skin graft, and other incisions achieved primary healing. All patients were followed up 12-36 months (mean, 23 months). X-ray films showed that bone union was achieved within 3-12 months (5.6 months on average). No related complication occurred, such as fixation loosening, refracture, infection, or immunological rejection. According to Merchan et al. criteria for knee joint function evaluation, the results were excellent in 7 cases, good in 9 cases, fair in 1 case, and poor in 1 case at last follow-up; the excellent and good rate was 88.9%. Anatomical plate combined with cortical bone plate allograft fixation is a good method to treat comminuted fractures of the femoral condyles. This method can effectively achieve complete cortical bone on the inside of the femur as well as provide rigid fixation.

  1. [Cementless total hip arthroplasty after acute femoral neck fracture in active patients. Prospective matched study with a minimum follow-up of 5 years].

    Science.gov (United States)

    Lizaur-Utrilla, A; Sanz-Reig, J; Miralles-Muñoz, F A

    2014-01-01

    To evaluate outcomes of cementless total hip replacement after acute femoral neck fracture in active patients. A prospective matched study was conducted to compare the results between 76 patients with fractures and 76 patients with osteoarthritis. The Harris score, short-WOMAC and SF-12 were used for the clinical assessment. The mean follow-up was 7.3 years (range 5-11). There were no significant differences in medical or surgical complications between the 2 groups. Functional outcomes were similar, but more walking aids were used in fracture group. There were 6 revisions among the fractures group (one dislocation, 2 deep infections, 3 aseptic loosening), and 2 aseptic loosening among controls. There was no significant difference in arthroplasty survival at 10 years (88.7 vs. 96.1%, P=.15). The mortality rates at 2 and 10 years were similar. Cementless total hip replacement for treatment of acute femoral neck fracture showed similar results to those of elective surgery for osteoarthritis in these selected patients. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  2. Variations of femoral condyle shape.

    Science.gov (United States)

    Biscević, Mirza; Hebibović, Mujo; Smrke, Dragica

    2005-12-01

    The aim of this study is to mathematically approximate the shape of the femoral articulating line and compare radiuses of condylar curves within and between males and females. Ten male and ten female participants were included in the study. Radiuses of medial and lateral condylar curves were calculated from the side view knee X-ray by original mathematical equation. Average radiuses of condylar curves were between 4.5 and 1.7 cm medially, and between 3.2 and 1.8 cm laterally, for 0 degrees and 90 degrees flexion contact point respectively. Males had longer curve radiuses of both condyles (p knee geometry, and other ellipsoidal structures in human body, like wrist, scull segments, dental arches, etc.

  3. Tension free femoral hernia repair with plug

    Institute of Scientific and Technical Information of China (English)

    Milivoje Vukovi; Neboja Moljevi; Sinia Crnogorac

    2013-01-01

    Objective: To investigate the conventional technique involves treatment of femoral hernia an approximation inguinal ligament to pectineal ligament. In technique which uses mesh closure for femoral canal without tissue tension. Method: A prospective study from January 01. 2007-May 30. 2009. We analyzed 1 042 patients with inguinal hernia, of which there were 83 patients with 86 femoral hernia. Result: Femoral hernias were present in 7.96% of cases. Males were 13 (15.66%) and 70 women (84.34%). The gender distribution of men: women is 1:5.38. Urgent underwent 69 (83%), and the 14 election (17%) patients. Average age was 63 years, the youngest patient was a 24 and the oldest 86 years. Ratio of right: left hernias was 3.4:1. With bilateral femoral hernias was 3.61% of cases. In 7 patients (8.43%) underwent femoral hernia repair with 9 Prolene plug. Conclusions: The technique of closing the femoral canal with plug a simple. The plug is made from monofilament material and is easily formed. This technique allows the reduction of recurrence and can be used safely, quickly and easily in elective and emergency situations.

  4. Aseptic loosening rate of megaprostheses and related factors%肿瘤型人工关节假体无菌性松动率及相关因素

    Institute of Scientific and Technical Information of China (English)

    肖何; 牛晓辉

    2014-01-01

    With the development of chemotherapy, imaging, surgical techniques and material science, limb-salvage has become a widely accepted concept in the treatment of bone and soft tissue tumors. Prosthetic reconstruction after tumor segment resection has become a common operation method. In the history, there appeared many kinds of materials for the reconstruction after the resection of tumors. The megaprosthesis has a history of more than 60 years, and has become the mainstream now, with many advantages over the other reconstruction materials. The aseptic loosening of megaprotheses is a common postoperative complication and also a prominent cause of prosthesis failure. How high is the aseptic loosening rate? Will the rate be affected by such factors as the patient’s age, gender, disease category, implantation site, reconstruction length, chemotherapy and so on? Will the rate be obviously reduced due to the improvement of megaprotheses? These questions are worth researching. The aseptic loosening rate of megaprostheses and related factors are reviewed in this article based on previous studies. According to previous reports, many factors concerning the patient and the prosthesis have an impact on the aseptic loosening rate. The clear and deifnite related factors included the implantation site, porous coating in the collar, type of articulation, age at the time of surgery and reconstruction length, and the gender and disease category are irrelevant factors. As to the size of intramedullary stem, ifxation mode, modular/custom and chemotherapy, their correlation with the aseptic loosening rate is still unclear.

  5. Transcriptome-Wide High-Density Microarray Analysis Reveals Differential Gene Transcription in Periprosthetic Tissue From Hips With Chronic Periprosthetic Joint Infection vs Aseptic Loosening.

    Science.gov (United States)

    Omar, Mohamed; Klawonn, Frank; Brand, Stephan; Stiesch, Meike; Krettek, Christian; Eberhard, Jörg

    2017-01-01

    Differentiating between periprosthetic hip infection and aseptic hip prosthesis loosening can be challenging, especially in patients with chronic infections. This study used whole-genome microarray analysis to investigate the transcriptomes of periprosthetic hip tissues to identify genes that are differentially transcripted between chronic periprosthetic hip infection and aseptic hip prosthesis loosening. In this pilot study, a total of 24 patients with either chronic periprosthetic hip infection (n = 12) or aseptic hip prosthesis loosening (n = 12) were analyzed. Periprosthetic hip infection was diagnosed based on modified criteria of the Musculoskeletal Infection Society. To evaluate differences in gene transcription, whole-genome microarray analysis was performed on the mRNA of periprosthetic tissue. Microarray analysis revealed differential gene transcription in periprosthetic hip tissue affected by chronic hip infection vs aseptic hip prosthesis loosening. A total of 39 genes had area under the curve values greater than 0.9 for diagnosing chronic periprosthetic hip infection; 5 genes had annotations relevant to infection and metabolism. The 39 genes also included 7 genes that were differentially transcribed but that have no apparent connection to immune response processes plus 27 genes with unknown function. Differences in gene transcription profiles might represent novel diagnostic targets that can be used to differentiate between chronic periprosthetic hip infections and aseptic hip prosthesis loosening. Secondary metabolites of differentially transcripted genes might serve as easily accessible markers for detecting chronic periprosthetic joint infection in future. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. The Effect of Lumbar Lordosis on Screw Loosening in Dynesys Dynamic Stabilization: Four-Year Follow-Up with Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao-Hung Kuo

    2015-01-01

    Full Text Available Introduction. This study aimed to evaluate the effects of Dynesys dynamic stabilization (DDS on clinical and radiographic outcomes, including spinal pelvic alignment. Method. Consecutive patients who underwent 1- or 2-level DDS for lumbar spondylosis, mild degenerative spondylolisthesis, or degenerative disc disease were included. Clinical outcomes were evaluated by Visual Analogue Scale for back and leg pain, Oswestry Disability Index, and the Japanese Orthopedic Association scores. Radiographic outcomes were assessed by radiographs and computed tomography. Pelvic incidence and lumbar lordosis (LL were also compared. Results. In 206 patients with an average follow-up of 51.1 ± 20.8 months, there were 87 screws (8.2% in 42 patients (20.4% that were loose. All clinical outcomes improved at each time point after operation. Patients with loosened screws were 45 years older. Furthermore, there was a higher risk of screw loosening in DDS involving S1, and these patients were more likely to have loosened screws if the LL failed to increase after the operation. Conclusions. The DDS screw loosening rate was overall 8.2% per screw and 20.4% per patient at more than 4 years of follow-up. Older patients, S1 involvement, and those patients who failed to gain LL postoperatively were at higher risk of screw loosening.

  7. The Effect of Lumbar Lordosis on Screw Loosening in Dynesys Dynamic Stabilization: Four-Year Follow-Up with Computed Tomography.

    Science.gov (United States)

    Kuo, Chao-Hung; Chang, Peng-Yuan; Tu, Tsung-Hsi; Fay, Li-Yu; Chang, Hsuan-Kan; Wu, Jau-Ching; Huang, Wen-Cheng; Cheng, Henrich

    2015-01-01

    This study aimed to evaluate the effects of Dynesys dynamic stabilization (DDS) on clinical and radiographic outcomes, including spinal pelvic alignment. Consecutive patients who underwent 1- or 2-level DDS for lumbar spondylosis, mild degenerative spondylolisthesis, or degenerative disc disease were included. Clinical outcomes were evaluated by Visual Analogue Scale for back and leg pain, Oswestry Disability Index, and the Japanese Orthopedic Association scores. Radiographic outcomes were assessed by radiographs and computed tomography. Pelvic incidence and lumbar lordosis (LL) were also compared. In 206 patients with an average follow-up of 51.1 ± 20.8 months, there were 87 screws (8.2%) in 42 patients (20.4%) that were loose. All clinical outcomes improved at each time point after operation. Patients with loosened screws were 45 years older. Furthermore, there was a higher risk of screw loosening in DDS involving S1, and these patients were more likely to have loosened screws if the LL failed to increase after the operation. The DDS screw loosening rate was overall 8.2% per screw and 20.4% per patient at more than 4 years of follow-up. Older patients, S1 involvement, and those patients who failed to gain LL postoperatively were at higher risk of screw loosening.

  8. The metal nanoparticle-induced inflammatory response is regulated by SIRT1 through NF-κB deacetylation in aseptic loosening.

    Science.gov (United States)

    Deng, Zhantao; Jin, Jiewen; Wang, Zhenheng; Wang, Yong; Gao, Qian; Zhao, Jianning

    2017-01-01

    Aseptic loosening is the most common cause of total hip arthroplasty (THA) failure, and osteolysis induced by wear particles plays a major role in aseptic loosening. Various pathways in multiple cell types contribute to the pathogenesis of osteolysis, but the role of Sirtuin 1 (SIRT1), which can regulate inflammatory responses through its deacetylation, has never been investigated. We hypothesized that the downregulation of SIRT1 in macrophages induced by metal nanoparticles was one of the reasons for osteolysis in THA failure. In this study, the expression of SIRT1 was examined in macrophages stimulated with metal nanoparticles from materials used in prosthetics and in specimens from patients suffering from aseptic loosening. To address whether SIRT1 downregulation triggers these inflammatory responses, the effects of the SIRT1 activator resveratrol on the expression of inflammatory cytokines in metal nanoparticle-stimulated macrophages were tested. The results demonstrated that SIRT1 expression was significantly downregulated in metal nanoparticle-stimulated macrophages and clinical specimens of prosthesis loosening. Pharmacological activation of SIRT1 dramatically reduced the particle-induced expression of inflammatory cytokines in vitro and osteolysis in vivo. Furthermore, SIRT1 regulated particle-induced inflammatory responses through nuclear factor kappa B (NF-κB) acetylation. Thus, the results of this study suggest that SIRT1 plays a key role in metal nanoparticle-induced inflammatory responses and that targeting the SIRT1 pathway may lead to novel therapeutic approaches for the treatment of aseptic prosthesis loosening.

  9. Xyloglucan Antibodies Inhibit Auxin-Induced Elongation and Cell Wall Loosening of Azuki Bean Epicotyls but Not of Oat Coleoptiles 1

    Science.gov (United States)

    Hoson, Takayuki; Masuda, Yoshio; Sone, Yoshiaki; Misaki, Akira

    1991-01-01

    Polyclonal antibodies were raised in rabbits against isoprimeverose (Xyl1Glc1), xyloglucan heptasaccharides (Xyl3Glc4), and octasaccharides (Gal1Xyl3Glc4). Antibodies specific for hepta- and octasaccharides suppressed auxin-induced elongation of epicotyl segments of azuki bean (Vigna angularis Ohwi and Ohashi cv Takara). These antibodies also inhibited auxin-induced cell wall loosening (decrease in the minimum stress-relaxation time and the relaxation rate of the cell walls) of azuki segments. However, none of the antibodies influenced auxin-induced elongation or cell wall loosening of coleoptile segments of oat (Avena sativa L. cv Victory). Auxin caused a decrease in molecular mass of xyloglucans in the cell walls of azuki epicotyls and oat coleoptiles. The antibodies inhibited such a change in molecular mass of xyloglucans in both species. Preimmune serum exhibited little or no inhibitory effect on auxin-induced elongation, cell wall loosening, or breakdown of xyloglucans. The results support the view that the breakdown of xyloglucans is associated with the cell wall loosening responsible for auxin-induced elongation in dicotyledons. The view does not appear to be applicable to poaceae, because the inhibition of xyloglucan breakdown by the antibodies did not influence auxin-induced elongation or cell wall loosening of oat coleoptiles. ImagesFigure 1Figure 2 PMID:16668221

  10. Femoral hernia sac laparoscopy: a case report.

    Science.gov (United States)

    Ramirez Valderrama, Alexander; Ruiz, Dan; Malik, Manmeet; Tiszenkel, Howard

    2014-01-01

    We present the case of a 64-year-old female with an incarcerated right femoral hernia, associated with a small bowel obstruction that was successfully treated with an open femoral hernia repair with plug. At the same time we performed a hernia sac laparoscopy to evaluate the viability of the previously reduced small bowel. The hernioscopy was performed with a 0° 5 mm scope with reliable evaluation of the peritoneal cavity. We confirm that hernioscopy is a safe and feasible procedure and provides useful information for the appropriate management of acute incarcerated femoral/inguinal hernias.

  11. Meralgia paresthetica and femoral acetabular impingement: a possible association.

    Science.gov (United States)

    Ahmed, Aiesha

    2010-12-11

    Meralgia paresthetica consists of pain and dysesthesia in the anterolateral thigh. Etiology is divided into spontaneous and iatrogenic causes. To my knowledge this has never been attributed to femoral acetabular impingement. This case highlights the presence of lateral femoral cutaneous neuropathy in the setting of femoral acetabular impingement syndrome thus raising the possibility of an association. Femoral acetabular impingement; Lateral femoral cutaneous nerve; Dysesthesia; Nerve conduction studies.

  12. Statistical time series methods for damage diagnosis in a scale aircraft skeleton structure: loosened bolts damage scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Kopsaftopoulos, Fotis P; Fassois, Spilios D, E-mail: fkopsaf@mech.upatras.gr, E-mail: fassois@mech.upatras.gr [Stochastic Mechanical Systems and Automation (SMSA) Laboratory Department of Mechanical and Aeronautical Engineering University of Patras, GR 265 00 Patras (Greece)

    2011-07-19

    A comparative assessment of several vibration based statistical time series methods for Structural Health Monitoring (SHM) is presented via their application to a scale aircraft skeleton laboratory structure. A brief overview of the methods, which are either scalar or vector type, non-parametric or parametric, and pertain to either the response-only or excitation-response cases, is provided. Damage diagnosis, including both the detection and identification subproblems, is tackled via scalar or vector vibration signals. The methods' effectiveness is assessed via repeated experiments under various damage scenarios, with each scenario corresponding to the loosening of one or more selected bolts. The results of the study confirm the 'global' damage detection capability and effectiveness of statistical time series methods for SHM.

  13. Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening--current concepts.

    Science.gov (United States)

    Cadosch, Dieter; Chan, Erwin; Gautschi, Oliver P; Filgueira, Luis

    2009-12-15

    Metal implants are essential therapeutic tools for the treatment of bone fractures and joint replacements. The metals and metal alloys used in contemporary orthopedic and trauma surgery are well tolerated by the majority of patients. However, complications resulting from inflammatory and immune reactions to metal implants have been well documented. This review briefly discusses the different mechanisms of metal implant corrosion in the human body, which lead to the release of significant levels of metal ions into the peri-implant tissues and the systemic blood circulation. Additionally, this article reviews the effects of the released ions on bone metabolism and the immune system and discusses their involvement in the pathophysiological mechanisms of aseptic loosening and metal hypersensitivity in patients with metal implants.

  14. Mini-mesh repair for femoral hernia

    National Research Council Canada - National Science Library

    Kulacoglu, Hakan

    2014-01-01

    Femoral hernia consists only 4% of all primary groin hernias. It is described as "the Bête Noire of Hernias" because of its nature and anatomy which is difficult to understand for the surgeons and tendency to recurrence...

  15. Radiation-induced femoral head necrosis

    African Journals Online (AJOL)

    2011-03-25

    Mar 25, 2011 ... osteonecrosis of the femoral head, following radiotherapy for a squamous cell .... therapy, alcoholism, gout/hyperuricemia, and idiopathic osteonecrosis. ... 15 pediatric patients treated for cancer in a major pediatric oncology ...

  16. Hydrocoele of a femoral hernia sac.

    Science.gov (United States)

    Mote, D G; Chakravarty, K B

    2009-12-01

    Hydrocoele of a femoral hernia sac is an extremely rare entity. Extensive literature review and Internet searching revealed only a few authentically reported cases. It mostly occurs in females during the fourth to sixth decades of life. The most common clinical presentation is groin swelling. It is diagnosed as an irreducible or incarcerated femoral hernia or subcutaneous lipoma. In almost all of the reported cases, the diagnosis of hydrocoele of a femoral hernia sac has been made only after surgical exploration. The present case is a 40-year-old lady who presented with a painless lump in the right groin and was diagnosed as a case of hydrocoele of a femoral hernia sac only after exploration.

  17. Herniography off femoral, obturator and perineal hernias

    Energy Technology Data Exchange (ETDEWEB)

    Ekberg, O.; Nordblom, I.; Fork, F.T.; Gullmo, A.

    1985-08-01

    Positive contrast herniography was used in the workup of 550 patients with unclear groin pain. The majority of these patients had rather characteristic hernias of indirect, direct or femoral type. However, now and then diagnostic problems arose. A femoral hernia may look like a direct or even obturator hernia. There is also a variety of multilocular femoral hernias and other types. A femoral hernia may be present together with other hernias in the ipsilateral or contralateral groin. Obturator hernias are usually small but are always confined to the obturator canal laterally in the obturator foramen. Abnormalities in the pouch of Douglas may include a deep rectogenital pouch, diverticula and true herniations. These uncommon herniographic findings are described and discussed.

  18. Acute appendicitis in a femoral hernia

    Directory of Open Access Journals (Sweden)

    Zdravković Darko

    2007-01-01

    Full Text Available INTRODUCTION Acute appendicitis in a femoral hernia is an uncommon condition that can be serious. Complications are more frequent if the diagnosis is delayed and surgery is not performed on time. CASE REPORT We present a 71-year-old man with a painful swollen mass. The patient presented with fatigue and loss of appetite, while body temperature was normal. The abdomen was not painful, and peristaltic was normal. All laboratory findings were normal. After anamnesis and physical examination, the presumed diagnosis was incarcerated femoral hernia and the patient was sent to the operating room. Intraoperative findings revealed an incarcerated femoral hernia within a phlegmonous inflammated appendix. Appendectomy and McVay hernioplastics were done. The postoperative course was without complications. CONCLUSION It is very important to bear in mind that right femoral hernia with signs of incarceration and inflammation may contain an acutely inflamed appendix. Delayed diagnosis and misdiagnosis cause greater morbidity and mortality.

  19. Penetration of a metallic femoral head through the acetabular shell.

    Science.gov (United States)

    Sherman, Robert A; Damron, Timothy A

    2009-10-01

    Extensive wear of a metal-on-polyethylene total hip arthroplasty may rarely result in erosion of the metal-backed acetabular shell and penetration of the femoral head. We report on the case of an 85-year-old man who presented to the emergency department with an apparent dislocated total hip. He subsequently was discovered to have a periprosthetic fracture after an attempt at closed reduction of what was only discovered intraoperatively to be an irreducible transacetabular component central dislocation. Recognition of this rare complication may change clinical outcome.

  20. Extended porous femoral stems in hip revisions.

    Directory of Open Access Journals (Sweden)

    Pablo Bruno

    2016-08-01

    Full Text Available Introduction: The porous coated cylindrical  stem are one of the most popular option in the set of hip revison surgery. The poupose of this study is present the clinical and radiographic results of a group of patients treated with this stem. Material and Methods: Between 1997 and 2010, we retrospectively evaluated 150 stem in 148 patients. The indication for revisión was aseptic loosening in 88 cases (58.6%, septic loosening in 41 cases (27.3%, periprosthetic fracture in 14 cases (9.3%, failed hip ostesynthesis in 4 cases (2.6% and stem fracture in 3 cases (2%. We followed the patient on average for 7.7 years. Results: We achived bone-ingrowth fixation in 135 patients (90 %,,  fibrous tissue fixation in 12 (8% and unstable fixation in 3 (2 %. The mean Harris hip score improved to 92 points at last follow-up. Three stem were revised (2%. One patient had revisión becouse of stem loosening. The other two becouse of deep infection required a 2 staged revision.  Three patient (2% had dislocation and was treated succesfully with closed reduction. Conclusion:  The porous coated cylindrical stem is a predictable technique with excellent survival rates  in  the set of  revisión hip surgery.

  1. Quantification of BaSO{sub 4} and polyacetal wear particles in the periprosthetic tissue around loosened isoelastic hip stems by nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Strazar, K. [Department of Orthopaedic Surgery, University Medical Center Ljubljana, Zaloska 9, 1000 Ljubljana (Slovenia); Kavcic, M. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia); Simcic, J. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia); Pelicon, P. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia)]. E-mail: primoz.pelicon@ijs.si; Smit, Z. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia); University of Ljubljana, Faculty of Mathematics and Physics, Jadranska 19, SI-1000 Ljubljana (Slovenia); Kump, P. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia); Jacimovic, R. [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, 1001 Ljubljana (Slovenia); Antolic, V. [Department of Orthopaedic Surgery, University Medical Center Ljubljana, Zaloska 9, 1000 Ljubljana (Slovenia); Coer, A. [Institute for Histology and Embryology, Medical Faculty Ljubljana, Korytkova 2, 1000 Ljubljana (Slovenia)

    2006-08-15

    The aim of this study was to quantify the amount of the biologically active wear particles in the periprosthetic tissue around loosened polyacetal isoelastic stems to find the pattern of their distribution in the periprosthetic tissue and determine their origin. Proton microbeam measurements of thin tissue sections enabled us identification and quantified elemental analysis of individual wear particles in the tissue. The Ba concentration measured on the wear particles matches the Ba concentration measured with in-air PIXE on the polyacetal stem directly proving the origin of the wear particles which suppose to play a decisive biological role in the process of premature aseptic loosening of polyacetal stems.

  2. Femoral nerve entrapment: a new insight.

    Science.gov (United States)

    Vázquez, M T; Murillo, J; Maranillo, E; Parkin, I G; Sanudo, J

    2007-03-01

    Compression of the femoral nerve in the iliac fossa has been reported as a consequence of several pathologies, but never as a result of muscular compression. Aberrant slips of iliacus, however, have occasionally been reported to cover or split the femoral nerve. This study aimed to assess such variations as potential factors in femoral nerve compression. A large and homogeneous sample of 121 embalmed cadavers (242 specimens) was studied. Statistical comparisons were made using the chi-squared test. Muscular slips from iliacus and psoas, piercing or covering the femoral nerve, were found in 19 specimens (7.9%). No significant differences by sex or side were found. The more frequent variation was piercing of the femoral nerve by a muscular slip (17 specimens, 7.0%). The nerve then entered the thigh as one or more branches. The less frequent variation found was a muscular slip or sheet covering the femoral nerve as it lay on iliacus (2 specimens, 0.8%). Each disposition may be a potential risk for nerve entrapment.

  3. 1 case of the femoral perforation with shortening deformity after tumor prosthesis replacement of the knee joint%肿瘤型膝关节置换术后股骨穿孔伴短缩一例

    Institute of Scientific and Technical Information of China (English)

    钱崇升; 蔡林; 任斌; 邓超华; 戢涛

    2012-01-01

    With the increase of the patients with knee tumor and the life extension after prosthetic replacement, the long-term complications of tumor prosthesis of the knee joint increase. It is difficult to deal with the loosening of the prosthesis and prosthetic subsidence and fractures. In 2011, 1 patient who had the femoral perforation with severe shortening deformity of the ipsilateral lower limb after tumor prosthesis replacement of the knee joint 20 years ago was adopted by our hospital. Now the treatment procedure was reported as follows.

  4. Stimulatory effect of zinc acexamate administration on fracture healing of the femoral-diaphyseal tissues in rats.

    Science.gov (United States)

    Igarashi, A; Yamaguchi, M

    1999-04-01

    The effect of zinc acexamate on fracture healing of the femoral-diaphyseal tissues in rats was investigated in vivo. Zinc acexamate (0.3 and 10.0 mg Zn/100 g body weight per day) was orally administered to rats (4 weeks old) surgically fractured the femoral diaphysis for 14 to 28 days. Calcium content and alkaline phosphatase activity in the femoral-diaphyseal tissues were significantly decreased in rats with fracture healing, while bone acid phosphatase activity and protein content were markedly increased. The administration of zinc acexamate (10.0 mg Zn/100 g) for 28 days caused a significant increase in calcium content, alkaline and acid phosphatases activities, protein and deoxyribonucleic acid (DNA) contents in the femoral-diaphyseal tissues of rats with fracture healing. With the lower dose (3.0 mg Zn/100 g), zinc compound had a partial effect on bone components. Femoral mineral density in rats with fracture healing was significantly increased by the administration of zinc acexamate (10.0 mg Zn/100 g) for 28 days. Femoral-diaphyseal zinc content was significantly decreased in rats with fracture healing. This decrease was completely restored by the administration of zinc acexamate (10.0 mg Zn/100 g) for 28 days. The present study suggests that the supplement of zinc compound stimulates fracture healing of the femoral-diaphyseal tissues in rats.

  5. Early follow-up of total hip arthroplasty with Accolade TMZF cementless femoral prosthesis%Accolade TMZF生物型股骨假体用于全髋置换的早期随访

    Institute of Scientific and Technical Information of China (English)

    朱永生; 徐耀增; 朱锋; 吴广鹏; 邵洪国

    2015-01-01

    BACKGROUND:Compared with the fixation of bone cement prosthesis,the fixation of cementless femoral prosthesis does not have the folowing worries,including cement-prosthesis separation,cement sheath rupture,and cement debris-induced osteolysis.Long-term outcomes are good,and the survival rate is high.OBJECTIVE: To observe the preliminary clinical results and complications of total hip arthroplasty with Accolade TMZF cementless femoral stem.METHODS:From February 2010 to July 2012,67 patients (70 hips) underwent primary total hip arthroplasty with cementless femoral stem.Al patients were treated with Accolade TMZF Biological hip prosthesis system.Femoral component was treated with the same Accolade TMZF cementless femoral stem.Acetabular component was treated with Secure-fit HA and Trident PSL HA.The first mortar joint friction surface was treated withceramic-ceramic composite in 49 hips,ceramic-polyethylene composite in 19 hips and metal-polyethylene composite in 2 hips.After replacement,hip imaging data were utilized to assess biological fixation of femoral stem prosthesis,osteolysis surrounding the prosthesis,and prosthesis subsidence,and to observe hip function,thigh pain and complications.RESULTS AND CONCLUSION:Al cases were folowed up for more than 2 years.The mean Harris hip score was (32.7±6.2) preoperatively,and improved to (89.2±5.1) during final folow-up.During final folow-up,four patients (6%) suffered from slight pain.No moderate and severe pain or extremely severe pain occurred.None of the patients needed second operation due to failure for various reasons.X-ray films showed that no prosthesis displacement or loosening.Bone fixation surrounding the prosthesis was visible at the femoral side.Only one hip had subsidence of less than 2 mm,and the remaining did not experience subsidence.No blood vessels or nerve injury appeared during the surgery.During prosthesis placement,femoral calcar cleavage fracture occurred in 4 hips,so wire cerclage was used

  6. Artificial Femoral Head Replacement in Treatment of 36 Patients with Osteoporotic Femoral Intertrochanteric Fracture%人工股骨头置换治疗骨质疏松性股骨粗隆间骨折36例

    Institute of Scientific and Technical Information of China (English)

    桑晓文; 杨利学; 谭龙旺; 孙智平; 张快强

    2014-01-01

    目的观察人工股骨头置换治疗骨质疏松性股骨粗隆间骨折的临床效果。方法对2008年1月-2013年6月收治的36例骨质疏松性股骨粗隆间骨折行加长柄双极骨水泥人工股骨头置换术,术后常规予鲑鱼降钙素联合钙剂抗骨质疏松治疗。结果术后Harris关节功能评分平均88分(68~94分),其中优18例,良13例,可4例,差1例,优良率为86.1%。2例术后活动后出现髋部轻度疼痛,1例下肢深静脉栓塞;本组均无髋关节脱位、假体周围再骨折、假体松动及下陷、大小粗隆骨折不愈合等并发症发生。结论人工股骨头置换术治疗骨质疏松性股骨粗隆间骨折可减少力学及内固定相关风险,且并发症少,效果良好。%Objective To observe the effect of artificial femoral head replacement in treatment of osteoporotic femoral inter-trochanteric fracture. Methods A total of 36 inpatients with osteoporotic femoral intertrochanteric fracture underwent long-stem ce-mented artificial femoral head replacement during January 2008 and June 2013, and routine salmon calcitonin combined with calcium of anti osteoporosis treatment was performed after operations. Results The postoperative Harris hip score was 88 (68-94), which included excellent in 18 cases, good in 13 cases, common in 4 cases and poor in 1 case, and the excellent and good rate was 86.1%. Two patients had postoperative hip mild pain after activity, and one patient had deep vein thrombosis of lower extremity, but there were no complications such as dislocation of hip joint, periprosthetic fracture, prosthesis loosening, subsidence and greater trochanteric fracture nonunion. Conclusion Artificial femoral head replacement in treatment of osteoporotic femoral intertrochanter-ic fracture can reduce the risks of mechanics and internal fixation with fewer complications and better effect.

  7. Mitigation of lake eutrophication: Loosen nitrogen control and focus on phosphorus abatement

    Institute of Scientific and Technical Information of China (English)

    Haijun Wang; Hongzhu Wang

    2009-01-01

    Traditionally, nitrogen control is generally considered an important component of reducing lake eutrophication and cyanobacteria blooms. However, this viewpoint is refuted recently by researchers in China and North America. In the present paper, the traditional viewpoint of nitrogen control is pointed out to lack a scientific basis: the N/P hypothesis is just a subjective assumption; bottle bioassay experiments fail to simulate the natural process of nitrogen fixation. Our multi-year comparative research in more than 40 Yangtze lakes indicates that phosphorus is the key factor determining phytoplankton growth regardless of nitrogen concentrations and that total phytoplankton biomass is determined by total phosphorus and not by total nitrogen concentrations. These results imply that, in the field, nitrogen control will not decrease phytoplankton biomass. This finding is supported by a long-term whole-lake experiment from North America. These outcomes can be generalized in terms that a reduction in nitrogen loading may not decrease the biomass of total phytoplankton as it can stimulate blooms of nitrogen-fixing cyanobacteria. To mitigate eutrophication, it is not nitrogen but phosphorus that should be reduced, unless nitrogen concentrations are too high to induce direct toxic impacts on human beings or other organisms. Finally, details are provided on how to reduce controls on nitrogen and how to mitigate eutrophication.

  8. Aetiology of femoral hernias revisited: bilateral femoral hernia in a young male (two cases).

    Science.gov (United States)

    Kochupapy, R T; Ranganathan, G; Dias, S; Shanahan, D

    2013-01-01

    Bilateral femoral hernias are less common in men than in women and rare in young adults. Only one case of a bilateral femoral hernia in a young man has been reported in the literature before. Three main theories have been postulated for femoral hernias. The theory that they are an acquired disease is the most accepted due to the common occurrence of such hernias in multiparous women but the theory lacks enough evidence. We report two cases in young men. Anatomical variations in the femoral canal could be the primary aetiological factor in these patients. A unilateral femoral hernia in young men with acquired aetiological factors requires a clinical examination of the opposite side.

  9. Evaluation of a pig femoral head osteonecrosis model

    Directory of Open Access Journals (Sweden)

    Kim Harry

    2010-03-01

    Full Text Available Abstract Background A major cause of osteonecrosis of the femoral head is interruption of a blood supply to the proximal femur. In order to evaluate blood circulation and pathogenetic alterations, a pig femoral head osteonecrosis model was examined to address whether ligature of the femoral neck (vasculature deprivation induces a reduction of blood circulation in the femoral head, and whether transphyseal vessels exist for communications between the epiphysis and the metaphysis. We also tested the hypothesis that the vessels surrounding the femoral neck and the ligamentum teres represent the primary source of blood flow to the femoral head. Methods Avascular osteonecrosis of the femoral head was induced in Yorkshire pigs by transecting the ligamentum teres and placing two ligatures around the femoral neck. After heparinized saline infusion and microfil perfusion via the abdominal aorta, blood circulation in the femoral head was evaluated by optical and CT imaging. Results An angiogram of the microfil casted sample allowed identification of the major blood vessels to the proximal femur including the iliac, common femoral, superficial femoral, deep femoral and circumflex arteries. Optical imaging in the femoral neck showed that a microfil stained vessel network was visible in control sections but less noticeable in necrotic sections. CT images showed a lack of microfil staining in the epiphysis. Furthermore, no transphyseal vessels were observed to link the epiphysis to the metaphysis. Conclusion Optical and CT imaging analyses revealed that in this present pig model the ligatures around the femoral neck were the primary cause of induction of avascular osteonecrosis. Since the vessels surrounding the femoral neck are comprised of the branches of the medial and the lateral femoral circumflex vessels, together with the extracapsular arterial ring and the lateral epiphyseal arteries, augmentation of blood circulation in those arteries will improve

  10. Comparison of femoral morphology and bone mineral density between femoral neck fractures and trochanteric fractures.

    Science.gov (United States)

    Maeda, Yuki; Sugano, Nobuhiko; Saito, Masanobu; Yonenobu, Kazuo

    2011-03-01

    Many studies that analyzed bone mineral density (BMD) and skeletal factors of hip fractures were based on uncalibrated radiographs or dual-energy xray absorptiometry (DXA). Spatial accuracy in measuring BMD and morphologic features of the femur with DXA is limited. This study investigated differences in BMD and morphologic features of the femur between two types of hip fractures using quantitative computed tomography (QCT). Forty patients with hip fractures with normal contralateral hips were selected for this study between 2003 and 2007 (trochanteric fracture, n=18; femoral neck fracture, n=22). Each patient underwent QCT of the bilateral femora using a calibration phantom. Using images of the intact contralateral femur, BMD measurements were made at the point of minimum femoral-neck cross-sectional area, middle of the intertrochanteric region, and center of the femoral head. QCT images also were used to measure morphologic features of the hip, including hip axis length, femoral neck axis length, neck-shaft angle, neck width, head offset, anteversion of the femoral neck, and cortical index at the femoral isthmus. No significant differences were found in trabecular BMD between groups in those three regions. Patients with trochanteric fractures showed a smaller neck shaft angle and smaller cortical index at the femoral canal isthmus compared with patients with femoral neck fractures. We conclude that severe osteoporosis with thinner cortical bone of the femoral diaphysis is seen more often in patients with trochanteric fracture than in patients with femoral neck fracture. Level IV, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

  11. Femoral articular geometry and patellofemoral stability.

    Science.gov (United States)

    Iranpour, Farhad; Merican, Azhar M; Teo, Seow Hui; Cobb, Justin P; Amis, Andrew A

    2017-06-01

    Patellofemoral instability is a major cause of anterior knee pain. The aim of this study was to examine how the medial and lateral stability of the patellofemoral joint in the normal knee changes with knee flexion and measure its relationship to differences in femoral trochlear geometry. Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum. The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, pgeometry with knee flexion to patellofemoral stability. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Biphasic threat to femoral head perfusion in abduction: arterial hypoperfusion and venous congestion

    Energy Technology Data Exchange (ETDEWEB)

    Yousefzadeh, David K. [Comer Children' s Hospital, Department of Radiology, Chicago, IL (United States); University of Chicago, Department of Radiology, Chicago, IL (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Johnson, Neil [Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States); Doerger, Kirk [Radiology Associates of Northern Kentucky, Crestview Hills, KY (United States); Sullivan, Christopher [University of Chicago, Department of Surgery, Chicago, IL (United States)

    2010-09-15

    Hip abduction can cause avascular necrosis (AVN) of the femoral head in infants. To compare the US perfusion pattern of femoral head cartilage in neutral position with that in different degrees and duration of abduction, testing the venous congestion theory of post-abduction ischemia. In 20 neonates, the Doppler flow characteristics of the posterosuperior (PS) branch of the femoral head cartilage feeding vessels were evaluated in neutral and at 30 , 45 , and 60 abduction. In three neonates the leg was held in 45-degree abduction and flow was assessed at 5, 10, and 15 min. Male/female ratio was 11/9 with a mean age of 1.86 {+-} 0.7 weeks. The peak systolic velocities (PSV) declined in all three degrees of abduction. After 15 min of 45-degree abduction, the mean PSV declined and showed an absent or reversed diastolic component and undetectable venous return. No perfusion was detected at 60-degree abduction. Abduction-induced femoral head ischemia is biphasic and degree- and duration-dependent. In phase I there is arterial hypoperfusion and in phase II there is venous congestion. A new pathogeneses for femoral head ischemia is offered. (orig.)

  13. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    Directory of Open Access Journals (Sweden)

    Thomas M Randau

    Full Text Available The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  14. Pseudoarthrosis in atypical femoral fracture: case report.

    Science.gov (United States)

    Giannotti, S; Bottai, V; Dell'Osso, G; De Paola, G; Ghilardi, M; Guido, G

    2013-11-01

    Atypical femoral fractures can be subsequent to a long-term biphosphonates treatment; they have a high frequency of delayed healing. The authors describe a femoral pseudoarthrosis of an atypical fracture treated with intramedullary nailing in a female after prolonged alendronate therapy. Atypical femoral fractures can be subsequent to a long-term biphosphonates treatment even if, in the literature, there is no clarity on the exact pathogenetic mechanism. The Task Force of the American Society for Bone and Mineral Research described the major and minor features to define atypical fractures and recommends that all the five major features must be present while minor features are not necessary. Another controversial aspect regarding the atypical femoral fractures is the higher frequency of the delayed healing that can be probably related to a suppressed bone turnover caused by a prolonged period of bisphosphonates treatment. This concept could be corroborated by the Spet Tc exam. In the case of a pseudoarthrosis, there is not a standardization of the treatment. In this report, the authors describe a femoral pseudoarthrosis of an atypical fracture treated with intramedullary nailing in a female after prolonged alendronate therapy; the patient was studied with clinical, bioumoral end SPECT-Tc exam of both femurs. Many studies show the relationship between bisphosphonates and the presence of atypical fractures. These fractures should be monitored more closely due to the risk of nonunion and they require considering an initial treatment with pharmacological augmentation to reduce the complications for the patient and the health care costs.

  15. Developmental dysplasia of the hip, age, BMI, place of residence and tobacco abuse increase the odds of aseptic loosening in Chinese patients.

    Directory of Open Access Journals (Sweden)

    Chuanlong Wu

    Full Text Available PURPOSE: The purpose of this hospital-based case-control study was to evaluate the patient-related risk factors for aseptic loosening after total hip arthroplasty (THA and total knee arthroplasty (TKA in Chinese patients. METHODS: From January 2000 to December 2012, 67 patients undergoing THA and TKA who developed aseptic loosening were detected as case subjects and 336 patients without aseptic loosening, matched by the year of index surgery and type of surgery, were selected as controls. Conditional logistic regression was used to compute odds ratios (ORs and 95% confidence intervals (CIs. RESULTS: The demographic factors and comorbid conditions associated with a risk-adjusted increase in aseptic loosening (in decreasing order of significance were a rural place of residence (OR = 2.28; 95% CI: 1.21-4.30; p = 0.011, body mass index (BMI ≥ 28 kg/m(2 (vs. 18.5-28 kg/m(2 (OR = 2.29; 95% CI: 1.19-4.41; p = 0.013, developmental dysplasia of the hip (DDH (OR = 2.91; 95% CI: 1.11-7.66; p = 0.030, tobacco abuse (OR = 2.88; 95% CI: 1.05-7.89; p = 0.039, and age <45 years (vs. 45-65 years (OR = 2.63; 95% CI: 1.01-6.80; p = 0.047. CONCLUSIONS: Patients aged <45 years and those with a BMI of ≥ 28 kg/m(2, a preoperative diagnosis of DDH, history of tobacco abuse, or living in rural areas are at increased risk for aseptic loosening after THA and TKA in Chinese population. Additional systematic large-scale studies are needed to verify these results.

  16. External fixation of femoral defects in athymic rats: Applications for human stem cell implantation and bone regeneration

    Directory of Open Access Journals (Sweden)

    Terasa Foo

    2013-01-01

    Full Text Available An appropriate animal model is critical for the research of stem/progenitor cell therapy and tissue engineering for bone regeneration in vivo. This study reports the design of an external fixator and its application to critical-sized femoral defects in athymic rats. The external fixator consists of clamps and screws that are readily available from hardware stores as well as Kirschner wires. A total of 35 rats underwent application of the external fixator with creation of a 6-mm bone defect in one femur of each animal. This model had been used in several separate studies, including implantation of collagen gel, umbilical cord blood mesenchymal stem cells, endothelial progenitor cells, or bone morphogenetic protein-2. One rat developed fracture at the proximal pin site and two rats developed deep tissue infection. Pin loosening was found in nine rats, but it only led to the failure of external fixation in two animals. In 8 to 10 weeks, various degrees of bone growth in the femoral defects were observed in different study groups, from full repair of the bone defect with bone morphogenetic protein-2 implantation to fibrous nonunion with collagen gel implantation. The external fixator used in these studies provided sufficient mechanical stability to the bone defects and had a comparable complication rate in athymic rats as in immunocompetent rats. The external fixator does not interfere with the natural environment of a bone defect. This model is particularly valuable for investigation of osteogenesis of human stem/progenitor cells in vivo.

  17. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, J.C. (Univ. of California, San Francisco); Hattner, R.S.; Murray, W.R.; Genant, H.K.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery and seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.

  18. Structural health monitoring for bolt loosening via a non-invasive vibro-haptics human-machine cooperative interface

    Science.gov (United States)

    Pekedis, Mahmut; Mascerañas, David; Turan, Gursoy; Ercan, Emre; Farrar, Charles R.; Yildiz, Hasan

    2015-08-01

    For the last two decades, developments in damage detection algorithms have greatly increased the potential for autonomous decisions about structural health. However, we are still struggling to build autonomous tools that can match the ability of a human to detect and localize the quantity of damage in structures. Therefore, there is a growing interest in merging the computational and cognitive concepts to improve the solution of structural health monitoring (SHM). The main object of this research is to apply the human-machine cooperative approach on a tower structure to detect damage. The cooperation approach includes haptic tools to create an appropriate collaboration between SHM sensor networks, statistical compression techniques and humans. Damage simulation in the structure is conducted by releasing some of the bolt loads. Accelerometers are bonded to various locations of the tower members to acquire the dynamic response of the structure. The obtained accelerometer results are encoded in three different ways to represent them as a haptic stimulus for the human subjects. Then, the participants are subjected to each of these stimuli to detect the bolt loosened damage in the tower. Results obtained from the human-machine cooperation demonstrate that the human subjects were able to recognize the damage with an accuracy of 88 ± 20.21% and response time of 5.87 ± 2.33 s. As a result, it is concluded that the currently developed human-machine cooperation SHM may provide a useful framework to interact with abstract entities such as data from a sensor network.

  19. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

    Directory of Open Access Journals (Sweden)

    Sampat S Dumbre Patil

    2016-01-01

    Full Text Available Background: When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN or surface implants like Dynamic Condylar Screw (DCS are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Materials and Methods: Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years and mean followup period was 52.1 months (range 27-72 months. Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. Results: All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Conclusions: Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.

  20. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

    Science.gov (United States)

    Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S

    2016-01-01

    Background: When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Materials and Methods: Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22–65 years) and mean followup period was 52.1 months (range 27–72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. Results: All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Conclusions: Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion. PMID:27512218

  1. Femoral hernia: a review of 83 cases.

    Science.gov (United States)

    Alimoglu, O; Kaya, B; Okan, I; Dasiran, F; Guzey, D; Bas, G; Sahin, M

    2006-03-01

    We evaluate the factors that affect morbidity and mortality in patients who underwent surgery due to femoral hernia. The medical records of 83 patients who underwent femoral hernia repair between January 1996 and June 2004 were retrospectively analyzed. The femoral hernias were repaired either with McVay or mesh plug hernioplasty. Sex, age, surgical repair technique, presence of incarceration/strangulation, incarcerated/strangulated organs, postoperative complications, duration of hospitalization, recurrence rate, and factors that affect mortality and morbidity were studied. There were 83 patients with femoral hernia in our study. Patients' age ranged from 10 to 75 years (mean age was 46.84) with a predominance of female (71%). Thirty-six patients (40%) underwent emergency surgery with the diagnosis of strangulation or incarceration of femoral hernia. Seventeen patients had strangulation and underwent resection; eleven of these patients had omentum in the hernial sac, whereas six patients had intestines. Four of these patients underwent laparotomy. The remaining 19 patients had incarceration and underwent simple reduction of hernial sac content without resection. Forty-seven (60%) patients underwent elective surgery. McVay technique was used for 79 patients, while the other four patients were treated with mesh-plug. Twelve patients (15%) developed a variety of complications (nine patients (25%) in emergency, three patients (6%) in elective group). There was one mortality. Recurrences occurred in two patients. Femoral hernia is an important surgical pathology with high rates of incarceration/strangulation and intestinal resection. Emergency surgery can increase morbidity and mortality especially in the elderly. Early elective surgery may reduce complication.

  2. Design and fabrication of uncemented femoral prosthesis using CAD/CAM/Robotic integration method%CAD/CAM/Robotic集成方法设计与制作生物型股骨柄假体

    Institute of Scientific and Technical Information of China (English)

    韩文龙; 朱建非; 吴琪; 刘昌华; 王爱民; 席文明

    2014-01-01

    BACKGROUND:In total hip replacements, aseptic loosening of uncemented femoral hip prosthesis is the main reason for the failure of artificial hip replacement, the prerequisite of reducing aseptic loosening of prosthesis is to increase fil ing area of femoral prosthesis in femoral cavity. OBJECTIVE:To obtain the fil ing rate of customized femoral prosthesis in femoral cavity and verify the validity of the methods of CAD/CAM/Robotic integration and the robot grind. METHODIn this paper, the CT data of femur were used to reconstruct three-dimensional model of femoral cavity. According to this model, a custom uncemented femoral hip prosthesis was designed, then the model of this custom prosthesis was imported into the CAD/CAM/Robotic software to generate cut path. After the cut path was imported into the robotic control er, the custom prosthesis can be fabricated, then this custom prosthesis was inserted into the femoral cavity, and the fil ing result of the custom prosthesis in femoral cavity was analyzed. RESULTS AND CONCLUSION:The experiment results showed that the customized prosthesis in femoral cavity achieved good fil ing result, the structure of femoral cavity resisted the rotation of the customized prosthesis in femoral cavity, and the customized prosthesis obtained stable fixation in the femoral cavity.%背景:生物型股骨柄假体无菌松动是全髋关节置换失败的主要因素,减少无菌松动的先决条件是增加股骨柄假体在股骨髓腔中的填充率。  目的:得到定制式股骨柄假体在髓腔中的填充率,验证计算机辅助设计/计算机辅助制造/工业机器人加工(CAD/CAM/Robotic)集成方法和机器人磨削的有效性。  方法:利用 CT 数据重建股骨髓腔三维模型,在此三维模型基础上设计股骨柄假体的柄体,依据标准直柄股骨柄假体近端模型设计股骨柄假体的其余部分。将设计的股骨柄假体模型导入CAD/CAM/Robotic集成系统生成机

  3. Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report.

    Science.gov (United States)

    Hatanaka, Hiroyuki; Motomura, Goro; Ikemura, Satoshi; Sonoda, Kazuhiko; Kubo, Yusuke; Utsunomiya, Takeshi; Yamamoto, Takuaki; Nakashima, Yasuharu

    2017-01-01

    The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. No Difference Between Trabecular Metal Cones and Femoral Head Allografts in Revision TKA: Minimum 5-year Followup.

    Science.gov (United States)

    Sandiford, Nemandra A; Misur, Peter; Garbuz, Donald S; Greidanus, Nelson V; Masri, Bassam A

    2017-01-01

    Encouraging clinical results have been reported with the use of femoral head structural allografts and, more recently, trabecular metal cones for the management of large structural defects of the femur and tibia during revision total knee arthroplasty (TKA). However, to our knowledge, there are no published studies comparing these two techniques. Compared with bulk allografts, do trabecular metal cones result in (1) better validated outcomes scores; (2) a lower risk of loosening or revision at 5 years; and (3) fewer surgical complications when used for the management of bone loss in revision TKA? Between 2002 and 2008, three surgeons performed 450 TKA revisions, 45 (10%) of which were performed using augmentation of host bone; in those, femoral head allograft was used in 30 (75%) and trabecular metal cones in 15 (25%). From 2002 to 2007, femoral head allografts were used in all patients (28 patients); from 2007 to 2008, trabecular metal augments were used in all patients. There was a period of 1 year (16 knees) in which there was some overlap; during that time, femoral head structural allografts were used in cases in which we were unable to fit the defect or achieve adequate stability with trabecular metal cones. Followup was at a mean of 9 years (range, 5-12 years). No patients were lost to followup. Knee function and quality of life were assessed using the Oxford Knee Score, WOMAC, SF-12, and the UCLA activity score. Radiographs were assessed for signs of loosening. Surgical complications included superficial or deep infections, iatrogenic fractures, symptomatic deep venous thromboses or pulmonary emboli, and blood loss requiring transfusion; these were obtained from our database and from review of patients' charts. The mean Oxford Knee Score in the allograft and trabecular metal cone groups was 91 (SD 10) and 91 (SD 14), respectively (95% confidence interval [CI], 88-94; p = 0.29). Mean WOMAC scores were 94 (SD 10) and 92 (SD 14), respectively (95% CI, 80-105; p

  5. Effect of boundary conditions on yield properties of human femoral trabecular bone.

    Science.gov (United States)

    Panyasantisuk, J; Pahr, D H; Zysset, P K

    2016-10-01

    Trabecular bone plays an important mechanical role in bone fractures and implant stability. Homogenized nonlinear finite element (FE) analysis of whole bones can deliver improved fracture risk and implant loosening assessment. Such simulations require the knowledge of mechanical properties such as an appropriate yield behavior and criterion for trabecular bone. Identification of a complete yield surface is extremely difficult experimentally but can be achieved in silico by using micro-FE analysis on cubical trabecular volume elements. Nevertheless, the influence of the boundary conditions (BCs), which are applied to such volume elements, on the obtained yield properties remains unknown. Therefore, this study compared homogenized yield properties along 17 load cases of 126 human femoral trabecular cubic specimens computed with classical kinematic uniform BCs (KUBCs) and a new set of mixed uniform BCs, namely periodicity-compatible mixed uniform BCs (PMUBCs). In stress space, PMUBCs lead to 7-72 % lower yield stresses compared to KUBCs. The yield surfaces obtained with both KUBCs and PMUBCs demonstrate a pressure-sensitive ellipsoidal shape. A volume fraction and fabric-based quadric yield function successfully fitted the yield surfaces of both BCs with a correlation coefficient [Formula: see text]. As expected, yield strains show only a weak dependency on bone volume fraction and fabric. The role of the two BCs in homogenized FE analysis of whole bones will need to be investigated and validated with experimental results at the whole bone level in future studies.

  6. Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss?

    Science.gov (United States)

    Berasi, Carl C; Berend, Keith R; Adams, Joanne B; Ruh, Erin L; Lombardi, Adolph V

    2015-02-01

    's surgeon to determine whether migration, fracture of fixation screws, or continued bone loss had occurred. There have been four subsequent surgical interventions: two failures secondary to sepsis, and one stem revision and one open reduction internal fixation for periprosthetic femoral fracture. There were two minor complications managed nonoperatively, but all of the components were noted to be well-fixed with no obvious migration or loosening observed on the most recent radiographs. Harris hip scores improved from a mean of 42 (SD, ±16) before surgery to 65 (SD, ±18) at latest followup (pacetabular triflange components represent yet another tool in the reconstructive surgeon's armamentarium. These devices can be helpful in situations of catastrophic bone loss. Level IV, therapeutic study.

  7. In Vivo Wear Performance of Cobalt-Chromium Versus Oxidized Zirconium Femoral Total Knee Replacements.

    Science.gov (United States)

    Gascoyne, Trevor C; Teeter, Matthew G; Guenther, Leah E; Burnell, Colin D; Bohm, Eric R; Naudie, Douglas R

    2016-01-01

    This study examines the damage and wear on the polyethylene (PE) inserts from 52 retrieved Genesis II total knee replacements to identify differences in tribological performance between matched pairs of cobalt-chromium (CoCr) and oxidized zirconium (OxZr) femoral components. Observer damage scoring and microcomputed tomography were used to quantify PE damage and wear, respectively. No significant differences were found between CoCr and OxZr groups in terms of PE insert damage, surface penetration, or wear. No severe damage such as cracking or delamination was noted on any of the 52 PE inserts. Observer damage scoring did not correlate with penetrative or volumetric PE wear. The more costly OxZr femoral component does not demonstrate clear tribological benefit over the standard CoCr component in the short term with this total knee replacement design.

  8. Loosening After Acetabular Revision

    DEFF Research Database (Denmark)

    Beckmann, Nicholas A.; Weiss, Stefan; Klotz, Matthias C.M.;

    2014-01-01

    The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years)...

  9. [Femoral venous catheter: an unusual complication].

    Science.gov (United States)

    Garcia, P; Mora, A; Trambert, P; Maler, E; Courant, P

    2000-08-01

    We report an erratic course of a venous femoral catheter which was in the abdominal cavity in a patient with an haemoperitoneum and an hepatic injury. This complication led to an inefficiency of the transfusion and a worsening of the haemoperitoneum.

  10. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Science.gov (United States)

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  11. Postmortem Femoral Blood Concentrations of Risperidone

    DEFF Research Database (Denmark)

    Linnet, Kristian; Johansen, Sys Stybe

    2014-01-01

    Postmortem femoral blood concentrations of the antipsychotic drug risperidone and the active metabolite 9-hydroxyrisperidone were determined by an achiral LC-MS/MS method in 38 cases. The cause of death was classified as unrelated to risperidone in 30 cases, in which the sum of the concentration ...

  12. Inadvertent femoral artery "stripping": surgical management.

    Science.gov (United States)

    Liddicoat, J E; Bekassy, S M; Daniell, M B; De Bakey, M E

    1975-02-01

    Following "vein stripping" for varicosities, two patients were referred to our service for evaluation of arterial insufficiency of the lower extremities. Both patients had had surgical interruption of the femoral arterial system which required reconstruction. This paper emphasizes the importance of understanding surgical anatomy and presents the techniques of successful surgical management of both cases.

  13. Intraoperative arteriography during femoral-popliteal bypass.

    Science.gov (United States)

    Liddicoat, J E; Bekassy, S M; DeBakey, M E

    1975-07-01

    Minor technical errors may jeopardize the patency of femoral-popliteal bypass grafts. In an attempt to detect such errors, intraoperative arteriography has been routinely employed. It allows immediate recognition and correction of the most common abnormal findings: intraluminal debris, intimal dissection, distal thrombosis, arterial spasm, and kinking of the graft.

  14. Radographic changes of the revascularized femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Rindell, K. (Orthopaedic Hospital of the Invalid Foundation, Helsinki (Finland). Department of Orthopeadic Surgery); Tallroth, K. (Orthopaedic Hospital of the Invalid Foundation, Helsinki (Finland). Department of Radiology); Lindholm, T.S. (Tampere University Central Hospital (Finland). Department of Surgery, Section of Orthopaedics and Traumatology)

    Twenty-two nerotic femoral heads in young adults were radiologically followed-up after grafting with vascularized bone by comparing the preoperative and the postoperative state of the hip joint. Three parameters were observed and followed; the flattening of the femoral head: the degree of osteoarthrosis of the joints; and the degree of incorporation of the graft into the recipient bone. The results, expressed by index figures, showed that the femoral head flattened during the first two years postoperatively; that the maximal incorporation occurred during the same period of time; and that the appearance of postoperative osteoarthrosis was slow during the first year and increased subsequently. This numerical characterization of radiological finding allows systematic individual analysis after revascularization of the femoral head with bone grafts. It is also suited for comparisons between patients, between series of patients and of various treatment techniques. Furthermore, this quatification provides a numerical index that seems to correlate with the outcome of the treated hip joint. (author). 12 refs.; 6 figs.; 1 tab.

  15. Prophylactic Nailing of Incomplete Atypical Femoral Fractures

    Directory of Open Access Journals (Sweden)

    Chang-Wug Oh

    2013-01-01

    Full Text Available Introduction. Recent reports have described the occurrence of low-energy subtrochanteric and femoral shaft fractures associated with long-term bisphosphonate use. Although information regarding the surgical treatment of these atypical femoral fractures is increasing, it is unclear if the preventive operation is useful in incomplete fractures. This study examined the results of preventive intramedullary nailing for incomplete atypical femoral fractures. Material and Methods. A retrospective search was conducted for patients older than 50 years receiving bisphosphonate therapy, with incomplete, nondisplaced fractures in either the subtrochanteric or diaphyseal area of the femur. Seventeen patients with a total of 20 incomplete, non-displaced lesions were included. The mean duration of bisphosphonate use was 50.5 months. Eleven of the 17 (64.7% patients had complete or incomplete fractures on the contralateral femur. All were treated with prophylactic fixation of an intramedullary (IM nail. The minimum followup was 12 months. Results. All cases healed with a mean period of 14.3 weeks. Nineteen of the 20 cases healed with the dissolution of incomplete fractures of the lateral aspect. A complete fracture developed at the time of nailing in one patient, but it healed with callus bridging. Conclusion. IM nailing appears to be a reliable way of preventing the progress of incomplete atypical femoral fractures.

  16. Tension free femoral hernia repair with plug

    Directory of Open Access Journals (Sweden)

    Milivoje Vuković

    2013-01-01

    Conclusions: The technique of closing the femoral canal with plug a simple. The plug is made from monofilament material and is easily formed. This technique allows the reduction of recurrence and can be used safely, quickly and easily in elective and emergency situations.

  17. Ipsilateral Acetabular and Femoral Neck and Shaft Fractures

    Directory of Open Access Journals (Sweden)

    Hideto Irifune

    2015-01-01

    Full Text Available Floating hip injuries and ipsilateral femoral neck and shaft fractures are rare. Additionally, the simultaneous occurrence of these injuries is extremely rare, and only one case report of the simultaneous occurrence of these injuries has been published. Here, we report the case of a patient with ipsilateral acetabular and femoral neck and shaft fractures following a suicide attempt. The patient experienced nonunion of the femoral neck and shaft after the initial operation and therefore underwent reconstruction using a femoral head prosthesis with a long stem and interlocking screws. Our procedure may be used in primary and/or secondary reconstruction for ipsilateral acetabular and femoral neck and shaft fractures.

  18. Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels.

    Science.gov (United States)

    Bacchi, Ataís; Paludo, Litiane; Ferraz Mesquita, Marcelo; Schuh, Christian; Federizzi, Leonardo; Oro Spazzin, Aloísio

    2013-04-26

    The aim of this study was to evaluate the effect of the prosthesis material (metal-acrylic resin or metal-ceramic) on loosening torque of the prosthetic screws in an implant-supported mandibular denture under two levels of vertical misfit. Ten frameworks were fabricated with commercially pure titanium, and five of them received acrylic resin and acrylic artificial teeth as veneering material and the other five were veneered with porcelain. Two levels of vertical fit were also created by fabricating 20 cast models to obtain four experimental groups according to the prosthesis material and misfit: Group 1 (metal-acrylic resin prosthesis with a passive fit); Group 2 (metal-acrylic resin prosthesis with a non-passive fit); Group 3 (metal-ceramic prosthesis with a passive fit); and Group 4 (metal-ceramic prosthesis with a non-passive fit). Two hundred prosthetic titanium-alloy screws were divided in 40 sets (five screws per set, n=10). After 24h, the loosening torque of the screws was evaluated using a digital torque meter. The results were submitted to two-way ANOVA analysis of variance followed by a Tukey's test (α=0.05). The mean values and standard deviations for each group were G1=7.05 (1.64), G2=5.52 (0.90), G3=6.46 (1.34), and G4=4.35 (0.99). Overall, the prosthesis material and misfit factors showed a statistically significant influence on the loosening torque (p<0.05). Metal-ceramic prosthesis and misfits decreased the loosening of the torque of the prosthetic screws.

  19. Surgical management of multiple posttraumatic arteriovenous fistulas of femoral vessels.

    Science.gov (United States)

    Pokrovsky, A V; Shubin, A A; Kuntsevich, G I; Subbotin, V V; Suntsov, D S

    2008-01-01

    Presented herein are two case reports concerning surgical management of posttraumatic arteriovenous fistulas of femoral vessels. Case 1. A 45-year-old female patient attended with a history of a shotgun injury wound of her left femur and crus sustained when a girl of eight. She sought medical attention for a progressively deteriorating condition, accompanied by pain, and breathlessness dyspnea at rest. Detected were multiple fistulas between the deep femoral artery and superficial femoral artery and femoral vein. Management consisted in separation of the arteriovenous fistulas, followed by prosthetic repair of the deep femoral artery. Case 2. A 32-year-old male patient after an accidentally inflicted shotgun injury of the his left femur underwent within a time period of 3 year three vascular operations including ligation of the deep femoral artery and femoral vein followed by having later on developed secondary lymphedema of his left lower limb and pronounced manifested chronic venous insufficiency. Management included dissociation of the numerous arteriovenous fistulas between the branches of the deep femoral artery and the common femoral artery, as well as between the superficial femoral artery and femoral vein.

  20. Computerized tomography analysis of aceptic necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Ichioka, Yoshiaki; Masuda, Takeshi; Matsuno, Takeo; Hasegawa, Isao; Sugano, Hiroki; Konno, Takushi.

    1988-03-01

    Computerized tomography (CT) findings of the normal femoral head in 14 patients with unilateral aceptic necrosis of the femoral head (ANF) and in healthy adults were analyzed for early diagnostic significance. CT appearance of the bone trabeculae fell into normal finding, diffuse sclerosis, and mottled sclerosis. The development of necrosis during the process was accompanied by diffuse sclerosis, suggesting that diffuse sclerosis is an early CT appearance in the case of ANF. In a three-dimensional quantification of the necrotic area for 20 patients before rotational osteotomy of the femoral head, deformation of the femoral head after the surgery was found to frequently result from 50 % or more of the necrotic area in the femoral head, irrespective of the size of necrosis on the surface of the femoral head. This suggested the influence of the three-dimensional spread of necrosis on the intensity of the femoral head. (Namekawa, K.).

  1. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The Association of Femoral Neck Stress Fractures with Femoral Acetabular Impingement

    Science.gov (United States)

    Safran, Marc R.; Goldin, Michael; Anderson, Christian; Fredericson, Michael; Stevens, Kathryn J.

    2013-01-01

    Objectives: To determine if there is an increased incidence of femoral acetabular impingement (FAI) in patients presenting with stress fractures of the femoral neck. Methods: After IRB approval, the imaging studies of 25 athletes (22 females, 3 males, mean age 26, range 19 - 39 years) with femoral neck stress injuries were assessed for the presence of features suggesting FAI, including acetabular retroversion, coxa profunda, abnormal femoral head-neck junction, fibrocystic change, os acetabulae, labral tear and chondral injury. All subjects had to have an adequate AP Pelvis radiograph, a lateral radiograph of the affected hip, and an MRI of the affected hip. The alpha angle, anterior offset ratio, and center to edge (CE) angle were measured on radiographs. The grade of stress injury was determined on MR images. All images and measurements were made by a musculoskeletal fellowship trained radiologist, a fellowship trained orthopaedic surgeon, an orthopaedic sports medicine fellow and a physical medicine and rehabilitation resident. Charts were reviewed to determine treatment of the stress fracture, outcome and final follow up, as well as to determine if the patient had any further treatment for their hip. Results: Of the 25 hips (18 right, 7 left) with femoral neck stress reactions, 9 were grade 2 (bone marrow edema), 5 were grade 3 (high T2 and low T1 marrow signal), and 11 were grade 4 (stress fracture). Twenty patients (80%) had coxa profunda - where the floor of the cotyloid fossa touches or extends beyond the ilioischial line (incidence in general population is 15.2% of males, and 19.4% of females). Coxa profunda, defined by the floor of the cotyloid fossa touching or extending beyond the ilioischial line and a center edge angle of more than 35o, was present in 28% of subjects. Acetabular retroversion as assessed by the crossover sign was present in 42% (normal incidence is 5% of population). Center edge angle was greater than 35o in 20% and greater than 40 o

  3. Dislocation and spontaneous reduction of the femoral implant against the femoral neck in an infected metal on metal hip resurfacing with complex collection

    Energy Technology Data Exchange (ETDEWEB)

    Tins, Bernhard, E-mail: Bernhard.Tins@rjah.nhs.uk [Department of Radiology, RJAH Orthopaedic Hospital, Oswestry, Shropshire, SY 107 AG (United Kingdom)

    2011-07-15

    Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections.

  4. Finite element analysis on longitudinal and radial functionally graded femoral prosthesis.

    Science.gov (United States)

    Oshkour, Azim Ataollahi; Abu Osman, N A; Davoodi, M M; Yau, Y H; Tarlochan, F; Wan Abas, W A B; Bayat, M

    2013-12-01

    This study focused on developing a 3D finite element model of functionally graded femoral prostheses to decrease stress shielding and to improve total hip replacement performance. The mechanical properties of the modeled functionally graded femoral prostheses were adjusted in the sagittal and transverse planes by changing the volume fraction gradient exponent. Prostheses with material changes in the sagittal and transverse planes were considered longitudinal and radial prostheses, respectively. The effects of cemented and noncemented implantation methods were also considered in this study. Strain energy and von Mises stresses were determined at the femoral proximal metaphysis and interfaces of the implanted femur components, respectively. Results demonstrated that the strain energy increased proportionally with increasing volume fraction gradient exponent, whereas the interface stresses decreased on the prostheses surfaces. A limited increase was also observed at the surfaces of the bone and cement. The periprosthetic femur with a noncemented prosthesis exhibited higher strain energy than with a cemented prosthesis. Radial prostheses implantation displayed more strain energy than longitudinal prostheses implantation in the femoral proximal part. Functionally graded materials also increased strain energy and exhibited promising potentials as substitutes of conventional materials to decrease stress shielding and to enhance total hip replacement lifespan.

  5. 人工关节假体植入后无菌性松动的发病机制%Pathogenesis of aseptic prosthesis loosening after artificial prosthesis implantation

    Institute of Scientific and Technical Information of China (English)

    马玉超; 田京

    2012-01-01

    BACKGROUND: There are many clinical researches on aseptic loosening of artificial prosthesis, but the exact pathogenesis is still unclear.OBJECTIVE: To review the pathogenesis of prosthesis aseptic loosening after artificial prosthesis implantation.METHODS: A computer-based online search of PubMed and CNKI was performed to search related articles published between 2006 and 2011 with the key words of “artificial prosthesis, aseptic loosening” both in English and Chinese. A total of 77 articles were obtained, and finally 38 articles were included.RESULTS AND CONCLUSION: Aseptic loosening after long-term total hip replacement is one of the main failure reasons. In the recent years, analysis of revision total hip replacement for failed hip arthroplasty showed that aseptic loosening is the chief reason. The mechanism of aseptic loosening mainly includes mechanical mechanisms, biological and other mechanisms. With further research and the improvement of implantation method and prosthetic materials, aseptic loosening will eventually be minimized, so that the service life of prosthesis will be longer.%背景:对于人工关节无菌性松动的基础和临床研究很多,但其确切机制仍不甚明确.目的:综述人工关节假体植入后无菌性松动的发病机制.方法:由第一作者应用计算机检索PubMed和中国期刊全文数据库2006/2011相关文献.在标题、摘要、关键词中以"artificial prosthesis,aseptic loosening"或"人工关节、无菌性松动"为检索词进行检索.共检索到77篇文献,最终纳入符合标准的文献38篇.结果与结论:无菌性松动已成为人工关节置换后远期失败的主要原因之一.近年来对人工全髋关节置换后翻修病例回顾性分析的统计显示,无菌性松动位于翻修原因第1位.关于人工关节无菌性松动的机制主要分为机械机制、生物机制及其他机制,它们的共同结果是造成骨吸收、骨溶解,最终导致假体松动.随着研究

  6. 基于压电主动传感方式的螺栓松动检测实验研究*%Bolt Loosening Detection Based on Piezoelectric Active Sensing Technology*

    Institute of Scientific and Technical Information of China (English)

    王涛; 罗毅; 刘绍鹏; 肖涵; 王志刚; 李友荣

    2013-01-01

    For the measurement of bolt axial force and detection of bolt loosening,the ultrasonic method is studied using the piezoelectric active sensing technique. When the ultrasonic wave generated by a piezoelectric patch propagates across the interface of the components jointed by the bolt,only part of the ultrasonic wave energy passes through it. The transmitted wave energy depends on the true contact area which is decided by the bolt pretension ac-cording to the Classical Hertz contact theory. By measuring the received energy with another piezoelectric patch on the other side of the connected components, the bolt pretension or bolt connection status can be detected. The experiment device is set up and serials experiments were carried out. The experiment results show that the wave energy propagated across the interface has good correlation with the torque level. This method has potential application for the monitoring of bolt loosening in-site.%针对螺栓联接结构中螺栓易松动而引发事故的情况,进行了压电主动传感方式的螺栓松动检测研究。采用压电材料激发超声波,根据透射波通过螺栓联接界面时,透射波携带的能量与界面间实际接触面积相关,而界面实际接触面积与界面压力(即螺栓作用力)成一定关系,通过测量透射波的能量确定螺栓的松紧程度。建立了实验装置,进行了实验研究。实验结果显示,作为传感器的压电材料所接收到的超声波能量与螺栓紧固力具有较好相关性,该方法可作为螺栓联接结构健康监测的一种新方法。

  7. Femoral bifurcation disease: balloon or knife.

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen

    2009-10-01

    Arterial occlusive disease at the level of the femoral bifurcation mostly occurs in combination with inflow and/or outflow lesions. Surgical endarterectomy of the femoral bifurcation is a well-proven low-risk and easy surgical intervention with known durable success, while, although proven to be safe, evidence is lacking about the durability of the endovascular approach. Based on the evidence at hand, the surgical approach should be recommended for the vast majority of patients and the endovascular approach should only be indicated as the first strategy in selected cases presenting with factors that might compromise the outcome of surgery in the groin. If feasible, the hybrid approach with endarterectomy at the level of the bifurcation and endovascular repair of the inflow and outflow lesions is preferred in patients with multilevel disease.

  8. Femoral head fracture without hip dislocation

    Institute of Scientific and Technical Information of China (English)

    Aditya K Aggarwal; Ashwani Soni; Daljeet Singh

    2013-01-01

    Femoral head fractures without dislocation or subluxation are extremely rare injuries.We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high energy trauma due to road traffic accident.He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39.He received cementless total hip replacement.At latest follow-up of 2.3 years,functional outcome was excellent with Harris hip score of 95.Such isolated injuries have been described only once in the literature and have not been classified till now.The purpose of this report is to highlight the extreme rarity,possible mechanism involved and a novel classification system to classify such injuries.

  9. Treatment of subtrochanteric femoral fracture with long proximal femoral nail antirotation

    Institute of Scientific and Technical Information of China (English)

    WANG Wen-yue; YANG Tian-fu; FANG Yue; LEI Ming-ming; WANG Guang-lin; LIU Lei

    2010-01-01

    Objective:Subtrochanteric femoral fractures are severe injuries.Although many treatment methods have been developed,controversy exists regarding the optimal management of these fractures.This study evaluated the clinical outcome of subtrochanteric femoral fractures fixed with long proximal femoral nail antirotation(PFNA-long).Methods:Between October 2006 and February 2008,25 patients with traumatic subtrochanteric fractures of the femur were treated with PFNA-long.Closed reduction and fixation were performed in 20 cases.In the remaining 5 cases,closed reduction was difficult,so limited open reduction was performed,with bone grafting in 4 cases and circumferential wiring in 4 cases.Results:The average follow-up time was 16.1 months.All subtrochanteric femoral fractures healed uneventfully except one case of delayed union.The mean union time was 26.2 weeks.Technical difficulties with nail insertion were encountered in 3 cases.No implant failure was observed.Conclusion:PFNA-long is effective in treatment of subtrochanteric femoral fractures,with a high rate of bone union,minor soft tissue damage,early return to functional exercise and few implant-related complications.

  10. [Avascular necrosis of the femoral head].

    Science.gov (United States)

    Porubský, Peter; Trč, Tomáš; Havlas, Vojtěch; Smetana, Pavel

    Avascular necrosis of the femoral head in adults is not common, but not too rare diseases. In orthopedic practice, it is one of the diseases that are causing implantation of hip replacement at a relatively early age. In the early detection and initiation of therapy can delay the implantation of prosthesis for several years, which is certainly more convenient for the patient and beneficial. This article is intended to acquaint the reader with the basic diagnostic procedures and therapy.

  11. Current concepts in total femoral replacement

    OpenAIRE

    Ramanathan, Deepak; Siqueira, Marcelo BP; Klika, Alison K.; Higuera, Carlos A.; Barsoum, Wael K.; Joyce, Michael J

    2015-01-01

    Total femoral replacement (TFR) is a salvage arthroplasty procedure used as an alternative to lower limb amputation. Since its initial description in the mid-20th century, this procedure has been used in a variety of oncologic and non-oncologic indications. The most compelling advantage of TFR is the achievement of immediate fixation which permits early mobilization. It is anticipated that TFR will be increasingly performed as the rate of revision arthroplasty rises worldwide. The existing li...

  12. Proximal femoral reconstruction with custom mega prosthesis

    OpenAIRE

    2003-01-01

    Seventy-seven patients with proximal femoral tumours underwent limb salvage surgery with custom mega prostheses between July 1989 and January 2002. We describe 44 cases with a mean follow-up of 57.8 months. Forty-one patients presented with malignant neoplasms of which 11 were malignant giant cell tumours, eight were chondrosarcoma and five were metastases. Wide margins were achieved for all malignant tumours, and marginal resection was done for all benign and metastatic lesions. Six patients...

  13. Radiofrequency ablation of two femoral head chondroblastomas

    Energy Technology Data Exchange (ETDEWEB)

    Petsas, Theodore [Department of Radiology, University of Patras (Greece); Megas, Panagiotis [Department of Orthopaedic Surgery, University of Patras (Greece)]. E-mail: panmegas@med.upatras.gr; Papathanassiou, Zafiria [Department of Radiology, University of Patras (Greece)

    2007-07-15

    Chondroblastoma is a rare benign cartilaginous bone tumor. Surgical resection is the treatment of choice for pain relief and prevention of further growth. Open surgical techniques are associated with complications, particularly when the tumors are located in deep anatomical sites. The authors performed RF ablation in two cases of subarticular femoral head chondroblastomas and emphasize its positive impact. The clinical course, the radiological findings and the post treatment results are discussed.

  14. Bisphosphonate-induced atypical subtrochanteric femoral fracture

    OpenAIRE

    2013-01-01

    The use of bisphosphonates (BPs) is universally accepted in the management of osteoporosis. However, a small percentage of patients have been recognised to develop atypical subtrochanteric fractures of the femur with the prolonged use of BPs. We report a rare case of bilateral insufficiency lesions in the proximal femora, where a major subtrochanteric fracture developed with a minor fall. This was successfully treated with internal fixation using proximal femoral nail.

  15. Ipsilateral femoral neck and trochanter fracture

    Directory of Open Access Journals (Sweden)

    Devdatta S Neogi

    2011-01-01

    Full Text Available Ipsilateral fractures in the neck and trochanteric region of the femur are very rare and seen in elderly osteoporotic patients. We present a case of a young man who presented with ipsilateral fracture of the femoral neck and a reverse oblique fracture in the trochanteric region following a motor vehicle accident. A possible mechanism, diagnostic challenge, and awareness required for identifying this injury are discussed.

  16. Fresh-Stored Osteochondral Allograft for Treatment of Osteochondritis Dissecans the Femoral Head

    Science.gov (United States)

    2010-01-01

    Masonis JL. Cementless femoral components in young patients: review and meta-analysis of total hip arthroplasty and hip resurfacing . J Arthroplasty...osteochondral allograft via a trochanteric osteotomy. Case Report A healthy 32-year-old man had worsening left hip pain after jumping off a vehicle from a...height of approximately 4 feet. In the subsequent months, the patient had mechan- ical symptoms of the affected hip , including catching and Each author

  17. Why large-head metal-on-metal hip replacements are painful: the anatomical basis of psoas impingement on the femoral head-neck junction.

    Science.gov (United States)

    Cobb, J P; Davda, K; Ahmad, A; Harris, S J; Masjedi, M; Hart, A J

    2011-07-01

    Large-head metal-on-metal total hip replacement has a failure rate of almost 8% at five years, three times the revision rate of conventional hip replacement. Unexplained pain remains a feature of this type of arthroplasty. All designs of the femoral component of large-head metal-on-metal total hip replacements share a unique characteristic: a subtended angle of 120° defining the proportion of a sphere that the head represents. Using MRI, we measured the contact area of the iliopsoas tendon on the femoral head in sagittal reconstruction of 20 hips of patients with symptomatic femoroacetabular impingement. We also measured the articular extent of the femoral head on 40 normal hips and ten with cam-type deformities. Finally, we performed virtual hip resurfacing on normal and cam-type hips, avoiding overhang of the metal rim inferomedially. The articular surface of the femoral head has a subtended angle of 120° anteriorly and posteriorly, but only 100° medially. Virtual surgery in a normally shaped femoral head showed a 20° skirt of metal protruding medially where iliopsoas articulates. The excessive extent of the large-diameter femoral components may cause iliopsoas impingement independently of the acetabular component. This may be the cause of postoperative pain with these implants.

  18. Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Simon J. M. Parker

    2015-01-01

    Full Text Available Background. Modular total hip arthroplasties are increasingly popular because customisation allows optimal restoration of patient biomechanics. However, the introduction of component interfaces provides greater opportunities for failure. We present a case of late nontraumatic dissociation of the head-neck interface, more than 10 years after insertion. Case Description. A 58-year-old woman had a left metal-on-metal total hip arthroplasty in 2002 for hip dysplasia. Following an uneventful 10-year period, she presented to hospital in severe pain after standing from a seated position, and radiographs demonstrated complete dissociation of the modular femoral head from the stem, with the femoral head remaining in its cup. There was no prior trauma or infection. Mild wear and metallosis were present on the articulating surface between the femoral head and trunnion. Soft tissues were unaffected. Discussion and Conclusions. This is the latest occurrence reported to date for nontraumatic component failure in such an implant by more than 7 years. The majority of cases occur in the context of dislocation and attempted closed reduction. We analyse and discuss possible mechanisms for failure, aiming to raise awareness of this potential complication and encouraging utmost care in component handling and insertion, as well as the long term follow-up of such patients.

  19. Prophylactic pinning for slipped capital femoral epiphysis: does it affect proximal femoral morphology?

    Science.gov (United States)

    Cousins, Gerard R; Campbell, Donald M; Wilson, Neil I L; Maclean, Jamie G B

    2016-05-01

    This study was designed to determine whether prophylactic pinning of the unaffected hip in unilateral slipped capital femoral epiphysis affects the proximal femoral morphology. Twenty-four hips prophylactically pinned were compared with 26 cases observed. The articulotrochanteric distance (ATD) and the trochanteric-trochanteric distance (TTD) were measured. Postoperative radiographs were compared with final follow-up radiographs. The final TTD : ATD ratio was higher (P=0.048) in the pinned group, suggesting relative coxa vara/breva. There was a smaller difference between the two hips in the prophylactically pinned group (0.7) as opposed to those observed (1.47). Prophylactic pinning does not cause growth to stop immediately but alters the proximal femoral morphology.

  20. Hybrid approach to limb salvage in the setting of an infected femoral-femoral bypass graft.

    Science.gov (United States)

    Jones, Douglas W; Meltzer, Andrew J; Schneider, Darren B

    2014-08-01

    Prosthetic vascular graft infection in patients with advanced peripheral arterial disease can lead to multiple additional procedures, including extra-anatomic bypass or even amputation. We report the case of an 88-year-old woman with critical limb ischemia and an infected prosthetic femoral-femoral bypass graft. Using a planned hybrid 2-stage approach, we performed endovascular recanalization of the native left iliac arterial system using remote access via the superficial femoral artery to avoid infected groin wounds. Recanalization of the patient's Trans-Atlantic Inter-Society Consensus II D chronic iliac occlusion allowed for removal of the infected graft and placement of a profunda femoris artery to proximal posterior tibial artery bypass, thereby restoring inflow and avoiding the infected left groin. Newer endovascular techniques coupled with open surgical options may lead to limb salvage in patients with previously unreconstructable peripheral arterial disease.

  1. MR evaluation of femoral neck version and tibial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, James Karl; Dwek, Jerry R. [University of California, San Diego, Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Pring, Maya E. [Rady Children' s Hospital, Department of Pediatric Orthopedic Surgery, San Diego, CA (United States)

    2012-01-15

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  2. Ipsilateral femoral neck and shaft fractures: An overlooked association

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H. (Dept. of Diagnostic Radiology, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA)); Riemer, B.L.; Butterfield, S.L. (Dept. of Orthopedic Surgery, Allegheny General Hospital, Pittsburgh, PA (USA) Medical Coll. of Pennsylvania, Pittsburgh, PA (USA))

    1991-05-01

    A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. (orig./GDG).

  3. Femoral neuropathy and meralgia paresthetica secondary to an iliacus hematoma.

    Science.gov (United States)

    Yi, Tae Im; Yoon, Tae Hee; Kim, Joo Sup; Lee, Ga Eun; Kim, Bo Ra

    2012-04-01

    Compressive femoral and lateral femoral cutaneous neuropathies from an iliacus hematoma are unusual presentation. We report a case of a 16-year-old boy who developed right femoral and lateral femoral cutaneous neuropathies as a complication of traumatic ipsilateral iliacus hematoma formation. The patient complained of numbness in the right thigh and calf as well as right leg weakness, and pain in the right inguinal area. Nerve conduction study and needle electromyography identified the neuropathies. After the electrodiagnostic studies, the pelvic bone MRI revealed a large, 9×5×4.5 cm right iliacus hematoma. As a result, diagnosis of a right iliacus hematoma compressing the femoral and lateral femoral cutaneous nerves was made, and the patient underwent an operation to remove the hematoma. Symptoms and neurological signs showed notable improvement after surgical decompression. Subsequent follow-up electrodiagnostic studies after 11 weeks demonstrated regeneration evidence.

  4. Management of femoral artery pseudoaneurysm due to addictive drug injection

    Institute of Scientific and Technical Information of China (English)

    李建文; 王三明; 陈小东

    2004-01-01

    Objective: To study surgical management for patients with femoral pseudoaneurysm resulting from addictive druginjection.Methods: Clinical data of 34 patients with femoral pseudoaneurysm resulting from addictive drug injection were retrospectively reviewed.Results: Thirteen patients underwent bypass graft ( end to side) of external iliac artery and superficial femoral artery using expanded polytetrafluoroethylene (ePTFE).Three patients who had an autogenous saphenous vein graft in situs, one of whom was then performed an ePTFE graft when rupture and bleeding occurred at the anastomotic site. Color Doppler image showed patent grafted blood vessels in all the patients after operation. Eighteen patients had their femoral arteries ligated. Limbs of all the 34 patients were saved.Conclusions: Ligating femoral artery is an effective way to treat femoral artery pseudoaneurysm if autogenous saphenous vein graft or artificial vessel graft is notapplicable.

  5. Bipolar femoral head replacement for the treatment of femoral neck fractures in elder Parkinson's disease patients%双极人工股骨头治疗老年帕金森患者股骨颈骨折

    Institute of Scientific and Technical Information of China (English)

    庄泽; 曾春; 曾花; 王昆

    2012-01-01

    BACKGROUND: Due to the muscle imbalance outcomes, Parkinson's patients are easy to fall and have a high risk of femoral neck fracture. OBJECTIVE: To explore the treatment outcomes of bipolar femoral head replacement for the femoral neck fractures in elder Parkinson's patients METHODS: A retrospective analysis was carried out on the clinical data of the 14 Parkinson's disease patients of femoral neck fractures, a total of 14 hips, who were treated with bipolar femoral head replacement. The patients were divided into three phases by Hoehn-Yahr classification, 3 cases in I phase, 4 cases in II phase, 5 cases in III phase and 2 cases in IV phase. The average surgery age was 62 to 83 years old. The Harris score, Fugl-Meyer scale and Unified Parkinson's Disease Rating Scale score were used as follow-up judgment. RESULTS AND CONCLUSION: The average follow-up time was 1 to 6 years. Harris score of 14 patients was postoperatively 85.4 better than preoperatively 22.3 (P < 0.05), Fugl-Meyer score was postoperatively 81.6 better than preoperatively 52.5 (P < 0.05). There was no significant difference of Unified Parkinson's Disease Rating Scale score before and after operation, and the Parkinson's disease controlled stable. No prosthesis loosening, dislocation or other complications. Early and mid-term follow-up showed under the effective medical control of the neurology drugs, bipolar femoral head replacement is a safe and effective treatment of femoral neck fracture for Hoehn-Yahr I -IV Parkinson's patient. There is relationship between the hip joint function and the control of the Parkinson's disease after replacement.%背景:帕金森患者由于肌力不平衡等原因更容易跌倒,发生股骨颈骨折的风险高.目的:观察双极人工股骨头置换对老年帕金森病合并股骨颈骨折患者的治疗效果.方法:回顾分析14例帕金森病合并股骨颈骨折行双极人工股骨头置换患者的临床资料,共14髋,Hoehn-Yahr分级Ⅰ期3例,Ⅱ期4

  6. Compartment Syndrome following Open Femoral Fracture with an Isolated Femoral Vein Injury Treated with Acute Repair

    Directory of Open Access Journals (Sweden)

    David Walmsley

    2014-01-01

    Full Text Available Acute compartment syndrome is a surgical emergency and its diagnosis is more difficult in obtunded or insensate patients. We present the case of a 34-year-old woman who sustained a Gustilo-Anderson grade III open midshaft femur fracture with an isolated femoral vein injury treated with direct repair. She developed lower leg compartment syndrome at 48 hours postoperatively, necessitating fasciotomies. She was subsequently found to have a DVT in her femoral vein at the level of the repair and was started on therapeutic anticoagulation. This case highlights the importance of recognition of isolated venous injuries in a trauma setting as a risk factor for developing compartment syndrome.

  7. Distal Femoral Locking Compression Plate Fixation in Distal Femoral Fractures: Early Results

    Directory of Open Access Journals (Sweden)

    EJ Yeap

    2007-05-01

    Full Text Available We conducted a retrospective review on eleven patients who were treated for Type A and C distal femoral fractures (based on AO classification between January 2004 and December 2004. All fractures were fixed with titanium distal femoral locking compression plate. The patient’s ages ranged from 15 to 85 with a mean of 44. Clinical assessment was conducted at least 6 months post-operatively using the Schatzker scoring system. Results showed that four patients had excellent results, four good, two fair and one failure.

  8. Synchronous femoral hernias diagnosed during endoscopic inguinal hernia repair.

    Science.gov (United States)

    Putnis, Soni; Wong, April; Berney, Christophe

    2011-12-01

    During totally extraperitoneal (TEP) endoscopic repair of inguinal hernias, it is possible to see the internal opening of the femoral canal. The aim of our study was to determine the incidence of synchronous femoral hernias found in patients undergoing TEP endoscopic inguinal hernia repair. This was a retrospective review of prospectively collected data on 362 consecutive patients who underwent 484 TEP endoscopic inguinal hernia repairs during a 5-year period, May 2005 to May 2010. During surgery, both inguinal and femoral canal orifices were routinely inspected. The presence of unilateral or bilateral inguinal and femoral hernias was recorded and repaired accordingly. There were a total of 362 patients. More males (343, 95%) underwent a TEP hernia repair than females (19, 5%). There were more cases of unilateral (240/362, 66%) than bilateral (122/362, 34%) inguinal hernias. A total of 18 cases of synchronous femoral hernias were found during operation. There was a higher incidence of femoral hernia in females (7/19, 37%) compared to males (11/343, 3%) (P hernias were clinically detectable preoperatively. Females undergoing elective inguinal hernia repair are more likely to have a synchronous femoral hernia than males. We suggest that all women presenting with an inguinal hernia also have a formal assessment of the femoral canal. TEP endoscopic inguinal hernia repair is an ideal approach as both inguinal and femoral orifices can be assessed and hernias repaired simultaneously during surgery.

  9. Magnetic resonance imaging and histopathology in the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Kokubo, Takashi

    1989-05-01

    To correlate the magnetic resonance (MR) images with the histopathological findings in the femoral head, the histopathology of 24 femoral heads, 15 with osteonecrosis, five with osteoarthritis and four with other hip disorders were subjected to preoperative MR imaging which demonstrated low intensity areas due to long T1 relaxation time in the femoral head. The MR signal was low where fibrovascular tissue, disintegrated fibrovascular tissue, amorphous necrotic material, bone, or cartilagenous tissue occupied the medullary space. From this study, it seems possible to predict the histopathologic changes in the femoral head using MR images. (author).

  10. A rare and frequently unrecognised pathology in children: femoral hernia.

    Science.gov (United States)

    Temiz, A; Akcora, B; Temiz, M; Canbolant, E

    2008-10-01

    A femoral hernia is the protrusion of the abdominal contents through the femoral canal. It accounts for less than 1% of all groin hernias in children and is often confused with inguinal hernia or other inguinal pathologies. Preoperative misdiagnosis has been reported to be between 40 and 75%. We believe that misdiagnosis and mistreatment usually occur due to insufficient physical examination, knowledge and experience about childhood femoral hernias. Here, we report and discuss the clinical appearance and treatment approach of three patients operated with the diagnosis of femoral hernias.

  11. Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures.

    Science.gov (United States)

    Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long

    2015-11-01

    The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.

  12. To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Abhishek, E-mail: abhiortho27@gmail.co [Department of Orthopedics, 513, Thermal Colony, Sector-22, Faridabad 121005, Haryana (India); Sankaran, Balu; Varghese, Mathew [Department of Orthopedics, St Stephen' s Hospital, Tis hazari, Delhi, New Delhi 110054 (India)

    2010-09-15

    Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck fracture are 87%, 88% and 87%, respectively. Type A or Type B curve pattern is a positive factor to successful osteosynthesis with p value <0.0001 (Chi-square test). This is a statistically significant value. From this finding it can be suggested that the reliability of dynamic curves A and B in predicting maintained vascularity of femoral head is high. This investigation can be used to predict the vascularity of femoral head after intracapsular femoral neck fractures. There was a good correlation between the outcomes of fractures and dynamic MRI curves done within 48 h of injury. This signifies the role of dynamic MRI in predicting the vascularity of femoral head as early as 48 h. A treatment algorithm can be suggested on the basis of dynamic MRI curves. The fractures with Type C dynamic curve should be considered as fractures with poor vascularity of femoral head and measures to enhance the vascularity of femoral head along with rigid internal fixation should be undertaken to promote

  13. Persistent knee complaints after retrograde unreamed nailing of femoral shaft fractures

    NARCIS (Netherlands)

    El Moumni, Mostafa; Schraven, Pim; ten Duis, Henk Jan; Wendt, Klaus

    2010-01-01

    Retrograde nailing is an attractive method for stabilisation of femoral shaft fractures in cases of polytrauma, ipsilateral pelvic, acetabular, tibial and femoral neck fractures, bilateral femoral fractures, obese and pregnant patients. However, retrograde nailing may result in complaints about the

  14. Role of Sonography in Clinically Occult Femoral Hernias.

    Science.gov (United States)

    Brandel, David W; Girish, Gandikota; Brandon, Catherine J; Dong, Qian; Yablon, Corrie; Jamadar, David A

    2016-01-01

    The purpose of this article is to evaluate the diagnostic accuracy of sonography in clinically occult femoral hernias and to describe our sonographic technique. The clinical and imaging data for 93 outpatients referred by general surgeons, all of whom underwent sonographic evaluation and surgery, were reviewed retrospectively. Of these, 55 patients who underwent surgical exploration for groin hernias within 3 months of sonography and met all inclusion criteria were included in the study. The sonographic technique involves using the pubic tubercle as an osseous landmark to identify and appropriately visualize the femoral canal. The Valsalva maneuver is then used to differentiate the movement of normal fat (a potential pitfall) from true herniation in the femoral canal. Surgical findings were used as the reference standard by which sonographic results were judged. Two-by-two contingency tables were used to calculate the sensitivity, specificity, positive predictive value, and negative predictive value. In these 55 patients, surgery revealed 15 femoral hernias. Eight femoral hernias occurred in women, and 7 occurred in men. For diagnosing femoral hernias, sonography demonstrated sensitivity of 80%, specificity of 88%, a positive predictive value of 71%, and a negative predictive value of 92%. True-positive cases of femoral hernias have a sonographic appearance of a hypoechoic sac with speckled internal echoes. When examining during the Valsalva maneuver, a femoral hernia passes deep to the inguinal ligament, expands the femoral canal, displacing the normal canal fat, and effaces the femoral vein. Sonography can exclude femoral hernias with high confidence in light of its exceptional negative predictive value. With attention to technique and imaging criteria, the diagnostic accuracy of sonography can be enhanced.

  15. Biogeometry of femoral neck for implant placement

    Directory of Open Access Journals (Sweden)

    Patwa J

    2006-01-01

    Full Text Available Background : Treatment of fracture neck femur with three cannulated cancellous screws in an apex proximal configuration is practised in many parts of the world. Methods : Dimensions of femoral neck at the middle of transcervical neck using CT scan (live neck and vernier caliper (dry cadeveric neck in 20 subjects respectively were measured. Results : Inferior half of the neck is narrower than superior half. Conclusion : Biogeometry of the neck of femur does not accomodate two inferior screws and thus fixation of fracture neck femur with three canulated cancellous screws in an apex distal configuration is recommended.

  16. Eosinophilic granuloma of the capital femoral epiphysis.

    Science.gov (United States)

    Goto, Takahiro; Nemoto, Tetsuo; Ogura, Koichi; Imanishi, Jungo; Hozumi, Takahiro; Funata, Nobuaki

    2011-05-01

    Eosinophilic granuloma occurs almost exclusively in the diaphysis or metaphysis, when tubular bones are affected. The investigators present an extremely rare case of eosinophilic granuloma arising at the epiphysis of the femoral head in an 8-year-old boy. Plain radiographs and computed tomography showed a well-circumscribed radiolucent lesion, suggesting chondroblastoma or Brodie's abscess. However, the findings on magnetic resonance images were different from typical features of chondroblastoma or Brodie's abscess. The lesion was curetted. Histological diagnosis was eosinophilic granuloma. Differential diagnoses of a radiolucent lesion at the epiphysis in a child should include, though quite rare, eosinophilic granuloma.

  17. Wedged tibial components for total knee arthroplasty.

    Science.gov (United States)

    Jeffery, R S; Orton, M A; Denham, R A

    1994-08-01

    Severe coronal deformity of the knee is frequently associated with erosion of one tibial condyle. This can cause problems with fixation and alignment during total knee arthroplasty. If the tibia is cut to the level of the more worn side, valuable bone is sacrificed; if the less worn side is chosen, the deficiency must be filled with bone--graft, cement, or a prosthesis. Tibial components with an integral polyethylene wedge on the undersurface were introduced in 1980 for use in patients with a bony deficit on one tibial condyle. The authors believe that the Denham prosthesis (Biomet, Wales, U.K.) was the first knee arthroplasty to offer such spacers. Twenty-six patients with preoperative varus deformity in whom a wedged component was used were compared with 29 historic control subjects. None of the wedged components loosened after a median follow-up period of 8 years compared with loosening in five of the control subjects (P = .01). In three of the control subjects a fractured triangle of cement was present on the radiographs. Use of the wedges was not accompanied by an improvement in postoperative alignment. The authors conclude that the wedges resulted in improved fixation that was independent of postoperative alignment.

  18. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    WU Li-dong (吴立东); HAHNE H.J.; HASSENPFLUG J.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3 mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface,the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81 mm and the average gap width was only 0.20 mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97 mm and the average gap width was 0.77 mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  19. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    吴立东; HAHNEH.J.; HASSENPFLUGJ.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface, the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81mm and the average gap width was only 0.20mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97mm and the average gap width was 0.77mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  20. fibular osteosynthesis of neglected femoral neck fracture in a young ...

    African Journals Online (AJOL)

    Where there are no facilities for microvascular surgery, non- ... fixation of a neglected femoral neck fracture associated with aseptic necrosis of femoral head in ... After a follow-up of two years, he had a Harris hip ... applied on the fifth postoperative day and patient was ... radiographic features that suggested aseptic necrosis.

  1. Femoral herniorrhaphy and its affect on fibrinogen levels

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... The study consists of 10 patients with features suggestive of femoral hernia ... development of post-operative thrombo embolic complications. ... the blood amongst our patients for femoral herniorrhaphy ... plasma fibrinogen level occur during and after surgery ... spinal anaesthesia has not been studied.

  2. Reference values for local arterial stiffness. Part B : femoral artery

    NARCIS (Netherlands)

    Bossuyt, Jelle; Engelen, Lian; Ferreira, Isabel; Stehouwer, Coen D; Boutouyrie, Pierre; Laurent, Stéphane; Segers, Patrick; Reesink, Koen; Van Bortel, Luc M

    2015-01-01

    OBJECTIVE: Carotid-femoral pulse wave velocity (PWV) is considered the gold standard measure of arterial stiffness, representing mainly aortic stiffness. As compared with the elastic carotid and aorta, the more muscular femoral artery may be differently associated with cardiovascular risk factors (C

  3. Femoral compressive neuropathy from iliopsoas haematoma complicating dengue hemorrhagic fever

    Institute of Scientific and Technical Information of China (English)

    Sneha Ganu; Yesha Mehta

    2013-01-01

    Dengue fever is a debilitating mosquito-borne disease caused by dengue virus. We reported a case of femoral compression neuropathy due to iliopsoas hematoma complicating dengue hemorrhagic fever. Iliopsoas muscle hematoma can cause femoral neuropathy with resultant pain and paralysis. Such manifestations are not well documented in the literature. The pathogenesis of hematoma and compressive neuropathy with its appropriate management is discussed.

  4. STRANGULATED FEMORAL HERNIA IN A MALE PATIENT – DIAGNOSTIC DILEMMA

    Directory of Open Access Journals (Sweden)

    Sapna

    2014-01-01

    Full Text Available Strangulated femoral hernia in a male patient is a very rare clinical presentation. Here we report a case of right inguinal swelling mimicking that of lymphadenopathy , later developing perforation due to strangulation of femoral hernia. Laparotomy with ileostomy was done

  5. SEXUAL DIMORPHISM OF MAXIMUM FEMORAL LENGTH

    Directory of Open Access Journals (Sweden)

    Pandya A M

    2011-04-01

    Full Text Available Sexual identification from the skeletal parts has medico legal and anthropological importance. Present study aims to obtain values of maximum femoral length and to evaluate its possible usefulness in determining correct sexual identification. Study sample consisted of 184 dry, normal, adult, human femora (136 male & 48 female from skeletal collections of Anatomy department, M. P. Shah Medical College, Jamnagar, Gujarat. Maximum length of femur was considered as maximum vertical distance between upper end of head of femur and the lowest point on femoral condyle, measured with the osteometric board. Mean Values obtained were, 451.81 and 417.48 for right male and female, and 453.35 and 420.44 for left male and female respectively. Higher value in male was statistically highly significant (P< 0.001 on both sides. Demarking point (D.P. analysis of the data showed that right femora with maximum length more than 476.70 were definitely male and less than 379.99 were definitely female; while for left bones, femora with maximum length more than 484.49 were definitely male and less than 385.73 were definitely female. Maximum length identified 13.43% of right male femora, 4.35% of right female femora, 7.25% of left male femora and 8% of left female femora. [National J of Med Res 2011; 1(2.000: 67-70

  6. Continuous blood gas monitoring in femoral arteries

    Science.gov (United States)

    Schlain, Les A.; Spar, Steven M.; Dellinger, Bart

    1995-05-01

    Continuous intra-arterial blood gas monitoring is a potentially valuable tool in the surgical and intensive care arenas. Patient oxygenation and acid base status can change rapidly and without warning. The ability to monitor pHa, PaCO2 and PaO2 in arterial blood will be a major medical advance for the anesthesiologist and intensivist. Intra-arterial blood gas sensors are typically placed in radial arteries. In certain patient populations accurate monitoring is not possible in radial arteries due to arterial environmental factors such as hypotension, vasoconstriction and atherosclerotic disease. These same factors can make radial cannulation difficult resulting in traumatic catheter insertion, thereby further compromising flow conditions. In situations where radial artery flow is expected to be compromised, selecting a large vessel for sensor placement is desirable. We report an initial feasibility study of our blood gas monitoring system using the femoral artery as the sensing site. Clinical results are presented as well as potential advantages and disadvantages associated with monitoring in the femoral artery.

  7. Patellar instability treated with distal femoral osteotomy.

    Science.gov (United States)

    Swarup, Ishaan; Elattar, Osama; Rozbruch, S Robert

    2017-06-01

    Patellar instability can cause significant disability in both pediatric and adult patients, and it is associated with several factors including genu valgum. In this study, we describe the role of a lateral opening wedge distal femoral osteotomy (DFO) combined with lateral retinacular release in addressing genu valgum with associated patellar instability. The rationale for this approach is to medialize the patellar tendon insertion and decrease the Q angle with DFO. A consecutive series of patients were studied, and our outcomes of interest included improvements in radiographic measures and patient outcomes. Radiographic improvement was assessed using patella congruency angle (PCA), mechanical axis deviation (MAD), and lateral distal femoral angle (LDFA). Patient outcomes were assessed using Oxford Knee scores, KOOS-PS scores, VAS pain scores, and Kujala scores. We studied eight patients (10 knees) that underwent a lateral opening wedge DFO for genu valgum and patellar instability. Mean follow-up duration was 27 months. PCA improved from 30.4° lateral preoperatively to 5.7° lateral postoperatively (p=0.016). Similarly, MAD improved from 33.1mm lateral to 6.5mm medial, and LDFA improved from 82.4° to 92.7° after surgery (p=0.002). There were significant improvements in VAS pain and Kujala scores after surgery (pgenu valgum. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Distal femoral osteotomy using a novel deformity reduction device.

    Science.gov (United States)

    Panichi, Enrico; Cappellari, Fulvio; Olimpo, Matteo; Piras, Lisa A; Radasch, Robert; Ferretti, Antonio; Peirone, Bruno

    2016-09-20

    Distal femoral osteotomy is a surgical procedure used to correct patellar luxation, secondary to a femoral deformity. A distal femoral osteotomy using the tibial plateau levelling osteotomy-jig to temporarily provide stability of the distal femoral osteotomy, maintaining limb alignment in the frontal and axial planes prior to internal plate fixation of the osteotomy, has been described. This report describes a novel jig named Deformity Reduction Device (DRD). This device was developed with the specific aim of increasing precision and predictability during corrective osteotomy execution in order to be consistent with the preoperative planning. The distal femoral osteotomy DRD-assisted procedure is described in detail, discussing the theoretical and practical principles of the application.

  9. Estimated carotid-femoral pulse wave velocity has similar predictive value as measured carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Greve, Sara V; Blicher, Marie K; Kruger, Ruan;

    2016-01-01

    BACKGROUND: Carotid-femoral pulse wave velocity (cfPWV) adds significantly to traditional cardiovascular risk prediction, but is not widely available. Therefore, it would be helpful if cfPWV could be replaced by an estimated carotid-femoral pulse wave velocity (ePWV) using age and mean blood pres...

  10. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases

    Directory of Open Access Journals (Sweden)

    Korkmaz MF

    2014-04-01

    Full Text Available Mehmet Fatih Korkmaz,1 Mehmet Nuri Erdem,2 Zeliha Disli,3 Engin Burak Selcuk,4 Mustafa Karakaplan,1 Abdullah Gogus5 1Department of Orthopedics and Traumatology, Inonu University School of Medicine, Malatya, Turkey; 2Department of Orthopedics and Traumatology, Nisantasi University School of Medicine, Istanbul, Turkey; 3Department of Anesthesiology, Malatya Government Hospital, Malatya, Turkey; 4Department of Family Medicine, Inonu University School of Medicine, Malatya, Turkey; 5Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul, Turkey Purpose: In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. Materials and methods: One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF classification and the American Society of Anesthesiologists' (ASA physical status classification (ASA grade. Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. Results: The mean age of the patients was 77.66 years (range: 37–98 years, and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range

  11. Late fiber metal shedding of the first and second-generation Harris Galante acetabular component. A report of 5 cases.

    Science.gov (United States)

    Mayman, David J; González Della Valle, Alejandro; Lambert, Edward; Anderson, John; Wright, Timothy; Nestor, Bryan; Sculco, Thomas P; Salvati, Eduardo A

    2007-06-01

    Five patients presented with fiber metal mesh shedding of a Harris Galante II acetabular cup detected between 11 and 15 years after implantation. All patients presented with hip pain and 4 demonstrated gross acetabular loosening and fiber metal separation on preoperative radiographs. The remaining patient underwent revision surgery because of a liner dislodgment and had a radiographically well fixed shell. Loosening and fiber metal separation were detected intraoperatively. Scanning electron microscopy of the retrieved shells demonstrated isolated diffusion bonding marks in the areas where the mesh separated from the substrate and no evidence of corrosion. Progressive osteolysis in the iliac bone was evident in 4 of our cases. Progressive iliac osteolysis may lead to loss of bone support in well-fixed cups and excessive stresses transferred to the interface between the fiber metal mesh and the titanium substrate leading to the separation of the 2 layers. Fiber metal separation may contribute to long-term loosening in the Harris Galante acetabular component.

  12. Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures

    Institute of Scientific and Technical Information of China (English)

    Paritosh Gogna; Reetadyuti Mukhopadhyay; Amanpreet Singh; Ashish Devgan; Sahil Arora; Amit Batra; Sushil Kumar Yadav

    2015-01-01

    Purpose:Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success.However,these implants require precise placement under image intensifier guidance,which exposes the surgeon to substantial amount of radiation.It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available.Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier.Methods:Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and internal fixation with reversed contralateral distal femoral locking plate.The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score.Results:Twenty-one fractures united with the primary procedure,with a mean time of consolidation being 11 weeks (range,9-16 weeks).One patient developed superficial suture line infection,which resolved with oral antibiotics.Another patient had a fall 3 weeks after surgery and broke the plate.Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united.Two cases had nonunion,which went in for union after bone grafting.The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97).Conclusion:The reversed contralateral distal femoral plate is a biomechanically sound implant,which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices.The added advantage of this implant is its usability in the absence of an image intensifier.

  13. Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients

    Directory of Open Access Journals (Sweden)

    Moretti Lorenzo

    2011-02-01

    Full Text Available Abstract Background Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN. The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA: implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads. Methods A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling. Results At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose. Conclusions On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.

  14. [Femoral angioplasty. Long-term results].

    Science.gov (United States)

    Foucart, H; Carlier, C; Baudrillard, J C; Joffre, F; Cécile, J P

    1990-01-01

    A study on the long-term efficacy of femoral-popliteal angioplasty was carried out on 185 angioplasty cases over a 5 year follow-up period. A classification of data according to the type of lesion treated, revealed that results were favorable in case of stenosis (87%), short obstruction (70%) and long obstruction (35%). A special study of the outcome of treatments for stage IV arteritis was carried out. After comparing results with those obtained by other teams, the authors list the complications encountered, hematomas, and thromboses, and show their current tendency for regression. Lastly, the authors stress the advantages of angioscopy, which permits to identify the nature of the treated lesions and to predict possible complications, which are usually underrated by angiography.

  15. Slipped capital femoral epiphysis in down syndrome.

    Science.gov (United States)

    Dietz, Frederick R; Albanese, Stephen A; Katz, Danielle A; Dobbs, Matthew B; Salamon, Peter B; Schoenecker, Perry L; Sussman, Michael D

    2004-01-01

    Slipped capital femoral epiphysis (SCFE) and Down syndrome are both uncommon in the population at large, and rarely are both conditions present in a single individual. Institutional records were searched for both Down syndrome and SCFE. At least 2 years of follow-up was required. Eight patients were identified. At presentation four patients could not walk due to pain and four could walk. Six of eight hips presented with grade III SCFE. Four hips were treated with internal fixation in situ and four were manipulatively reduced in the operating room at the time of fixation with percutaneous screws or pins. Three hips healed uneventfully. Five hips developed aseptic necrosis (three partial, two whole head). This small retrospective study suggests an extremely high rate of complications in adolescents with Down syndrome and SCFE.

  16. Slipped upper femoral epiphysis with hemophilia A

    Directory of Open Access Journals (Sweden)

    Iyer Deepa

    2007-01-01

    Full Text Available A 13-year-old boy who had hemophilia A was reported with pain in the left thigh and hip on walking. He had no history of trauma. Severe hemophilia A is diagnosed with a Factor VIII level of < 1 iu/dl. The presumptive diagnosis was that of a spontaneous bleed into the hip joint. Factor VIII mutational analysis revealed a C to G substitution at nucleotide 6683 which results in a cystine change at codon 2194. However, the symptoms persisted and an X-ray demonstrated the presence of an acute on chronic slip of the upper femoral epiphysis. The patient was transferred to the center treating his hemophilia where the hip was pinned in situ under cover with Factor VIII. This case demonstrates the need to be aware of a possible traumatic diagnosis of hip pain in a hemophiliac child with a longstanding history of spontaneous bleeding into joints.

  17. FEMORAL MONONEUROPATHY: COMPLICATING A DIFFICULT PELVIC URETEROLITHOTOMY

    Directory of Open Access Journals (Sweden)

    D. Mehraban

    1996-07-01

    Full Text Available Femoral mononeuropathy is a complication of gynecological and urological operations. Tlte objective of this citse report is to bring to the attention of fellow urologists the very existence of this complication and offer measures to prevent it. A 48 year old obese worman with a 2 year history of frequent left renal colics, anil a nonfunction left kidney on IVP underwent a retrograde ureterogram study anil a transvaginal ureterolithotomy, in an exaggerated lithotomy position. Postoperatively, a left leg paralysis required 3 weeks of care and encouragement to heal. To prevent this complication, avoid putting too long and too much pressure by retractors on the psoas muscles. During the abdomino-perineal procedures, frequent change of retractor site and monitoring of distal arterial pulses would he helpful. Also, do not use the exaggerated lithotomy position for an extended period of time.

  18. Atypical subtrochanteric and diaphyseal femoral fractures

    DEFF Research Database (Denmark)

    Shane, Elizabeth; Burr, David; Abrahamsen, Bo

    2014-01-01

    Bisphosphonates (BPs) and denosumab reduce the risk of spine and nonspine fractures. Atypical femur fractures (AFFs) located in the subtrochanteric region and diaphysis of the femur have been reported in patients taking BPs and in patients on denosumab, but they also occur in patients...... with no exposure to these drugs. In this report, we review studies on the epidemiology, pathogenesis, and medical management of AFFs, published since 2010. This newer evidence suggests that AFFs are stress or insufficiency fractures. The original case definition was revised to highlight radiographic features...... that distinguish AFFs from ordinary osteoporotic femoral diaphyseal fractures and to provide guidance on the importance of their transverse orientation. The requirement that fractures be noncomminuted was relaxed to include minimal comminution. The periosteal stress reaction at the fracture site was changed from...

  19. Treatment of postcatheterization femoral arteriovenous fistulas with simple prolonged bandaging

    Institute of Scientific and Technical Information of China (English)

    ZHOU Tao; LIU Zhen-jiang; ZHOU Sheng-hua; SHEN Xiang-qian; LIU Qi-ming; FANG Zhen-fei; HU Xin-qun; LI Jiang; L(U) Xiao-lin

    2007-01-01

    Background The methods for the treatment of postcatheterization femoral arteriovenous fistulas (AVF-s) - simple observation, ultrasound guided compression, covered stents implantation and coil embolization have poor outcome.Surgery is the standard method for treatment of femoral AVFs, but it is a traumatic operation. In this study, we report the results of the treatment of postcatheterization femoral AVFs by simple prolonged compressing bandage.Methods To treat iatrogenic femoral AVFs caused by transfemoral catheterization, prolonged binding with elastic or common bandage was applied in 16 cases. Catheterization was performed in 7 cases for radiofrequency current catheter ablation, in 4 for occlusion of congenital heart disease, in 3 for percutaneous coronary intervention, in 1 for coronary angiography and in 1 for right heart catheterization.Results All iatrogenic femoral AVFs were healed after simple binding with elastic or common bandage for 4-46 days (mean (15±10) days). During the period of binding, local skins ulceration occurred at puncture site in two cases and femoral vein thrombus was found in one patient. During 6-24 months (mean (11.8±3.6) months) followup with colour Doppler ultrasonography, no recurrent arteriovenous shunting or other complications were observed.Conclusion The results suggest that simple prolonged bandaging for postcatheterization femoral AVFs is an effective and economical procedure.

  20. Intestinal Obstruction due to Bilateral Strangulated Femoral Hernias

    Directory of Open Access Journals (Sweden)

    Ioannis Nikolopoulos

    2014-01-01

    Full Text Available Introduction. Femoral hernias are at high risk of strangulation due to the narrow femoral canal and femoral ring. This can lead to symptoms of obstruction or strangulation requiring emergency surgery and possible bowel resection. To our knowledge, there is only one previous published report of bilateral strangulated femoral hernia. We present our case of this phenomenon. Case Report. An 86-year-old woman presented with symptoms of small bowel obstruction. Examination revealed two tender lumps in the area of the femoral triangle. CT scan revealed bilateral femoral hernias. Both hernias were repaired and a small bowel resection on the right side was performed with side to side anastomosis. She made an uneventful recovery. Conclusion. Bilateral femoral hernias are a rare occurrence with only one reported case of bilateral strangulation. Our case highlights the importance of meticulous history taking and clinical examination as any delay in diagnosis will increase the risk of mortality and morbidity for the patient. Hernias should always be considered as a cause if one presents with symptoms of abdominal pain or obstruction.

  1. Biomechanical Analysis Of The Proximal Femoral Locking Compression Plate: Do Quality Of Reduction And Screw Orientation Influence Construct Stability?

    Science.gov (United States)

    Zderic, Ivan; Oh, Jong-Keon; Stoffel, Karl; Sommer, Christoph; Helfen, Tobias; Camino, Gaston; Richards, R Geoff; Nork, Sean E; Gueorguiev, Boyko

    2017-08-22

    To investigate biomechanically in a human cadaveric model the failure modes of the Proximal Femoral Locking Compression Plate (PF-LCP) and explore the underlying mechanism. Twenty-four fresh-frozen paired human cadaveric femora with simulated unstable intertrochanteric fractures (AO/OTA 31-A3.3) were assigned to four groups with six specimens each for plating with PF-LCP. The groups differed in the quality of fracture reduction and plating fashion of the first and second proximal screws as follows: 1) anatomical reduction with on-axis screw placement; 2) anatomical reduction with off-axis screw placement; 3) malreduction with on-axis screw placement; 4) malreduction with off-axis screw placement. The specimens were tested until failure using a protocol with combined axial and torsional loading. Mechanical failure was defined as abrupt change in machine load-displacement data. Clinical failure was defined as 5° varus tilting of the femoral head as captured with optical motion tracking. Initial axial stiffness (N/mm) in groups 1 to 4 was 213.6±65.0, 209.5±134.0, 128.3±16.6 and 106.3±47.4, respectively. Numbers of cycles to clinical and mechanical failure were 16642±10468 and 8695±1462 in group 1, 14076±3032 and 7449±5663 in group 2, 8800±8584 and 4497±2336 in group 3 and 9709±3894 and 5279±4119 in group 4. Significantly higher stiffness as well as numbers of cycles to both clinical and mechanical failure were detected in group 1 in comparison to group 3, P≤0.044. Generally, malreduction led to significantly earlier construct failure. The observed failures were cut-out of the proximal screws in the femoral head, followed by either screw bending, screw loosening or screw fracture. Proper placement of the proximal screws in anatomically reduced fractures led to significantly higher construct stability. Our data also indicates that once the screws are placed off-axis (>5 degrees), the benefit of an anatomic reduction is lost.

  2. Our Experience with Patello femoral joint replacement

    Science.gov (United States)

    Ramos, Pablo; Arteaga, Gonzalo; Vargas, Medardo; Naranjo, Juan

    2017-01-01

    Background: Ten to fifteen percent of knee arthritis is reported to be isolated patellofemoral arthritis. Total knee arthroplasty is not recommended for isolated patella femoral arthritis particularly in young patients. We present the retrospective review our series in 7 years. Objectives: The aim of this presentation is to describe our experience in the management of patellofemoral osteoarthritis with the use of the partial patellofemoral arthroplasty, as well as to delineate the pitfalls and causes of revision in our initial series of 153 cases. Methods: between 2009 and 2016, our group performed 157 patellofemoral arthroplasties (PFA) 74% being in women, and 26% in men, the mean age for women was 58 yrs. And 38 yrs. for men, our initial 13 cases were managed with the Avon prosthesis (Stryker Corporation Kalamazoo, Michigan), and then we switched to the Vanguard PF (Zimmer-Biomet Warsaw In), both systems are an On-Lay design that is more flexible for addressing dysplastic trochleas that are more common in our population. Results: We performed a Knee Osteoarthritis Outcome Score (KOOS) for the assessment of the success of the procedure and obtained 87% of patients with excellent results (95 to 100), 10% with fair results (70 to 90) and 3% with poor outcomes (50), we performed a total of 3 revisions due to pain or progress to global arthritis. Conclusion: The PFA is a successful, safe and reproducible surgery that can be used in the group of patients that have isolated patellofemoral osteoarthritis. It requires a thorough knowledge of the patello femoral joint biomechanics, and physiopathology.

  3. Treatment of the femoral neck peudoarthrosis in childhood: Case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2013-01-01

    Full Text Available Introduction. Femoral neck fractures in children and adolescents are rare. However, their complications are frequent - avascular necrosis, femoral neck pseudoarthrosis, premature physeal closure with consequent growth disturbance and coxa vara deformity. Case Outline. A 9.5­year­old boy was injured in a car accident, and femoral neck fracture was diagnosed. Prior to admission at our hospital he was surgically treated several times. He was admitted at our hospital eight months following the accident. On the X­ray transcervical pseudoarthrosis of the femoral neck was found, as well as coxa vara deformity and metaphyseal avascular necrosis. He was operated at our hospital; all previously placed ostefixation material was removed, valgus osteotomy of 30 degrees was done as well as additional local osteoplasty using the commercial osteoindactive agent (Osteovit®. Postoperatively, we applied skin traction, bed rest and physical therapy. At the final follow­up, the patient was recovered completely. He is now painless, the legs are of equal length, range of movements in the left hip is full, life activity is normal. The X­ray shows that the femoral neck pseudoarthrosis is fully healed. Conclusion. This case is presented in order to encourage other colleagues to challenge the problematic situation such as this one. Also, we would like to remind them what one should think about and what should be taken into consideration in the primary treatment of femoral neck fractures in children. Valgus femoral osteotomy, as a part of the primary treatment of femoral neck fracture in children (identically as in the adults can prevent the occurrence of femoral neck pseudoarthrosis.

  4. MORPHOLOGICAL STUDY OF MEDIAL CIRCUMFLEX FEMORAL ARTERY IN HUMAN CADAVERS

    Directory of Open Access Journals (Sweden)

    Brijesh R. Aghera

    2014-10-01

    Full Text Available Background: Medial circumflex femoral artery is an important branch of Profunda femoris artery. It is an important artery in supplying blood to the head and neck of the femur, the adductor muscles and form anastomosis around head of femur. So study of variation of medial circumflex femoral artery great value for surgeon and orthopaedic surgeries. Materials and Methods: The present study includes 102 lower limbs of adult formalin fixed human cadavers used for the routine dissection procedure for under graduate and post graduate students in the department of Anatomy, M.R. Medical College, KBN Medical college and H K E Homeopathic College, Gulbarga (India during 2011-2014.The study was done by dissection method as per Cunningham’s manual of practical Anatomy. Result: In present study, we found that 25 extremities (25.49% medial circumflex femoral artery was originated directly from femoral artery. In 10 extremities (9.80% a common trunk was observed form medial circumflex femoral with femoral artery. Normal study was observed in 66 extremities (64.70%. Conclusion: In present study and other past studies we conclude that knowledge of variation in this artery is very important to preventing injury to vessels during surgical procedures around hip joint and also has important value in plastic surgery operations as the vascular pedicle of grafts such as the transverse upper gracilis (TUG flap, medial thigh flap and medial circumflex femoral (gracilis perforator free flap. During case of selective arteriography in ischaemic necrosis of the femoral head to know the arterial supply of the femoral head it is used.

  5. Bilateral impacted femoral neck fracture in a renal disease patient

    Directory of Open Access Journals (Sweden)

    Pramod Devkota

    2013-01-01

    Full Text Available Spontaneous bilateral femoral neck facture in a renal disease patient is not common. We report a case of 47-year-old female patient with chronic renal failure and on regular hemodialysis for the past 5 years who sustained bilateral impacted femoral neck fracture without history of trauma and injury and refused any surgical intervention. The patient was mobilised on wheel chair one year after the fractures. The cause of the fracture and the literature review of the bilateral femoral neck fracture in renal disease are discussed.

  6. Neurapraxia of the femoral nerve in a modern dancer.

    Science.gov (United States)

    Sammarco, G J; Stephens, M M

    1991-01-01

    We have presented a case of an acute onset femoral nerve neurapraxia in a pure modern dancer. Repeated mild stretching of the femoral nerve during an established dance routine over a period of several months is implicated as the etiology. The thigh muscles quickly weakened, but regained strength within 3 months. Electromyographic evidence of specific femoral nerve injury initially was negative, but was evident 6 weeks following injury. Overuse syndrome in dancers can cause rapid loss of strength. Other conditions such as herniated intervertebral disc, acute hemorrhage, trauma, iliopsoas rupture, and acute stretching must be ruled out. Complete recovery was the natural outcome.

  7. Bilateral nonunited femoral neck fracture in a child with osteopetrosis.

    Science.gov (United States)

    Steinwender, G; Hosny, G A; Koch, S; Grill, F

    1995-01-01

    We report a case of osteopetrosis with bilateral nonunited femoral neck and coxa vara in a 7-year-old boy. There was a history of traumatic transcervical left femoral neck fracture unsuccessfully treated by internal fixation. We performed a bilateral subtrochanteric valgus osteotomy. K-Wire fixation failed on the right side due to hardness of the bone. Finally, internal fixation with an angular plate after predrilling of the femoral neck offered stability. Bone union was achieved on both sides, resulting in full recovery of normal physical activity.

  8. Artificial femoral head replacement for proximal femoral malignant tumors in middle-aged and elderly patients%中老年人股骨上段恶性肿瘤人工股骨头置换治疗效果分析

    Institute of Scientific and Technical Information of China (English)

    赵洪普; 徐秋玉; 吕玉明; 曾勉东; 钟志宏

    2012-01-01

    目的 探讨中老年人股骨上段恶性肿瘤人工股骨头置换治疗的近期疗效.方法 6例原发性骨肿瘤和11例转移性骨肿瘤患者,均接受了瘤段骨切除和人工股骨头置换手术治疗.术后2周开始二膦酸盐类药物口服或静脉治疗,随访中就患者的临床表现、局部影像学、疼痛情况及患侧肢体术后功能进行评定.结果 术后所有患髋疼痛基本缓解,关节活动功能恢复满意,可满足日常行走和负重需要.随访3~40个月,观察期内无假体松动、脱位及近假体骨折等,手术局部无肿瘤复发.术后以髋关节Harris评分,关节功能优良率为88.2%.结论 对中老年人股骨近段骨间室内恶性肿瘤采用人工股骨头重建,可有效缓解疼痛,保留肢体功能,提高生存质量.%Objective To evaluate the short-term effect of artificial femoral head replacement ( AFHR )for proximal femoral malignant tumors in middle-aged and elderly patients. Methods Seventeen patients with proximal femoral malignant tumors,including,6 cases of primary tumors and 11 cases of me-tastatic, were treated with local resection and AFHR. Two weeks later, bisphosphonates were administrated orally or intravenously. Clinical manifestation, pain complaints and limb function were evaluated during the follow-up period. Results In all patients, the hip joint pain was almost relived and the functional recovery was satisfactory, which were sufficient for normal walking and weight-bearing activities. Function and daily life were restored after operation. The hip function was evaluated with Harris s score, AND excellent or good outcomes were obtained by 88. 2%( 15 of 17 cases ). The follow-up period ranged from 3 to 40 months( average,18.7 months ). Prosthesis loosening, prosthesis dislocation, peri-prosthetic fracture and local tumor recurrence were not observed. Conclusion In middle-aged and elderly patients, proximal femoral replacement can provide good pain relief, hip

  9. Estudio radiológico de anteversión femoral

    OpenAIRE

    Oller Asensio, Antonio; Oller Arcas, Javier

    2005-01-01

    La deformidad torso rotacional de las extremidades inferiores es un desorden esquelético frecuente, de gran importancia y es causa de alteración de la marcha. La anteversión femoral corresponde a la inclinación anterior de la cabeza femoral con respecto al eje bicondíleo femoral. El cuello femoral está normalmente en anteversión con respecto al plano bicondilar femoral.

  10. Treatment of osteonecrosis of the femoral head using autologous cultured osteoblasts: a case report

    Directory of Open Access Journals (Sweden)

    Kim Seok-Jung

    2008-02-01

    Full Text Available Abstract Introduction Osteonecrosis of the femoral head is a progressive disease that leads to femoral head collapse and osteoarthritis. Our goal in treating osteonecrosis is to preserve, not to replace, the femoral head. Case presentation We present the case of a patient with bilateral osteonecrosis of the femoral head treated with autologous cultured osteoblast injection. Conclusion Although our experience is limited to one patient, autologous cultured osteoblast transplantation appears to be effective for treating the osteonecrosis of femoral head.

  11. Hip Hemiarthroplasty for Femoral Neck Fractures Using the Modified ...

    African Journals Online (AJOL)

    The patients had good hip abduction postoperatively. In addition ... Key words: Femoral neck fractures, hip hemiarthroplasty, ... the overall blood loss at surgery and morbidity after surgery, ... Their clinical and demographic features were noted.

  12. Management of Bilateral Femoral Fractures in Pregnancy: A Case ...

    African Journals Online (AJOL)

    Management of Bilateral Femoral Fractures in Pregnancy: A Case Report. ... There was no history of loss of consciousness, abdominal pains or vaginal bleeding. ... and manage the pregnancy to the point where the baby is safe for delivery.

  13. Spontaneous Enterocutaneous Fistula: A Rare Presentation of Incarcerated Femoral Hernia

    National Research Council Canada - National Science Library

    Meriç Emre Bostanci; Ilker Özel; Birkan Bozkurt; Sinan Soylu; Mustafa Turan

    2015-01-01

      Although femoral hernias are less commonly seen compared with other types of hernias, they have an inversely proportional importance to its lower frequency because of its higher risk of strangulation...

  14. Cell therapy for avascular osteonecrosis of femoral head

    Directory of Open Access Journals (Sweden)

    Tomoki Aoyama

    2009-04-01

    Full Text Available Avascular osteonecrosis of femoral head causes severe musculoskeletal disability. There is not standard treatment to cure avascular osteonecrosis.? Recently, cell therapy using bone marrow stromal cells has begun for this disease.

  15. Outcome of Femoral Plate Osteosynthesis in a Teaching Hospital in ...

    African Journals Online (AJOL)

    Valued eMachines Customer

    The scope of femoral fracture is wide and generally high energy forces are involved with multi- system trauma in ... concentration and packed cell volumes. One hundred and .... Alternatives include traction with or without cast bracing, plate.

  16. Acute femoral neuropathy secondary to an iliacus muscle hematoma.

    Science.gov (United States)

    Seijo-Martínez, M; Castro del Río, M; Fontoira, E; Fontoira, M

    2003-05-15

    We present a patient with a spontaneous iliacus muscle hematoma, appearing immediately after a minor physical maneuver, presenting with pain and femoral neuropathy initially evidenced by massive quadriceps muscle fasciculations. A magnetic resonance imaging (MRI) study of the pelvic area confirmed the diagnosis, showing a hematoma secondary to a partial muscle tear. The patient was managed conservatively, and the continuous muscle activity ceased in 3 days, with progressive improvement of the pain and weakness. The recovery was complete. Femoral neuropathy is uncommon and usually due to compression from psoas muscle mass lesions of diverse nature, including hematomas. Usually subacute, femoral neuropathy may present acutely in cases of large or strategically placed compressive femoral nerve lesions, and may require surgical evacuation. The case presented herein is remarkable since the muscle hematoma appeared after a nonviolent maneuver, fasciculations were present at onset, and conservative management was sufficient for a full recovery.

  17. Cost of treatment of paediatric femoral shaft fractures: compression ...

    African Journals Online (AJOL)

    Cost of treatment of paediatric femoral shaft fractures: compression plating versus conservative treatment. ... Log in or Register to get access to full text downloads. ... Results: Thirty-one patients who had ORIF and 31 matched controls were ...

  18. The quadratus femoris graft in old transcervical femoral fractures.

    Directory of Open Access Journals (Sweden)

    Delima D

    1989-07-01

    Full Text Available Sixteen patients with an old transcervical femoral fracture were treated with the quadratus femoris muscle pedicle bone graft with supplementary autografting. The result was a good functional hip in 14 cases.

  19. Effectiveness of plate augmentation for femoral shaft nonunion after nailing

    Directory of Open Access Journals (Sweden)

    Chin-Jung Lin

    2012-08-01

    Conclusion: Plate augmentation with retention of the nail with autologous bone grafting may be an effective and reliable alternative in treating nonunion of the femoral shaft fracture after open reduction and internal fixation with intramedullary nail.

  20. Delayed appearance of hypaesthesia and paralysis after femoral nerve block

    Directory of Open Access Journals (Sweden)

    Stefan Landgraeber

    2012-03-01

    Full Text Available We report on a female patient who underwent an arthroscopy of the right knee and was given a continuous femoral nerve block catheter. The postoperative course was initially unremarkable, but when postoperative mobilisation was commenced, 18 hours after removal of the catheter, the patient noticed paralysis and hypaesthesia. Examination confirmed the diagnosis of femoral nerve dysfunction. Colour duplex sonography of the femoral artery and computed tomography of the lumbar spine and pelvis yielded no pathological findings. Overnight the neurological deficits decreased without therapy and were finally no longer detectable. We speculate that during the administration of the local anaesthetic a depot formed, localised in the medial femoral intermuscular septa, which was leaked after first mobilisation. To our knowledge no similar case has been published up to now. We conclude that patients who are treated with a nerve block should be informed and physician should be aware that delayed neurological deficits are possible.

  1. Forum. Femoral neck surgery using a local anaesthetic technique.

    Science.gov (United States)

    Howard, C B; Mackie, I G; Fairclough, J; Austin, T R

    1983-10-01

    Thirty cases of femoral sub-capital fractures, Garden grades 1-4, were reduced and internally fixed with crossed Garden screws using femoral nerve block. In addition, sedation and analgesia was provided by low dose ketamine and diazepam. No deaths or other complications occurred in these patients. In a similar group of patients who received spinal analgesia in the same unit under similar conditions there was one death and two cerebrovascular accidents.

  2. Periprosthetic subtrochanteric femoral fracture in a megaprosthesis of the knee

    Directory of Open Access Journals (Sweden)

    Vaishya Raju

    2013-10-01

    Full Text Available 【Abstract】We report a rare case of periprosthetic posttraumatic fracture of subtrochanteric region of femur after a megaprosthesis of the knee, done for resistant nonunion of distal femur with secondary osteoarthrosis in a 51 years old man. Treatment with a locking femoral plate was able to achieve primary union with a good result. Key words: Periprosthetic fractures; Femur; Femoral fractures; Knee

  3. Brodie's abscess of the femoral neck simulating osteoid osteoma.

    Science.gov (United States)

    Gulati, Yash; Maheshwari, Aditya V

    2007-10-01

    Subacute osteomyelitis (Brodie's abscess) is essentially a problem of diagnosis, and there may be considerable difficulty in distinguishing it from other benign and malignant bone lesions. Though reported in the metaphyseal region of the femur, Brodie's abscess is rarer in the femoral neck. The authors present a case of Brodie's abscess in the femoral neck, which clinico-radiologically simulated an osteoid osteoma. Retrospectively, the presence of a cortical sinus tract should have aroused suspicion.

  4. Femoral Neck Shaft Angle in Men with Fragility Fractures

    Directory of Open Access Journals (Sweden)

    S. P. Tuck

    2011-01-01

    Full Text Available Introduction. Femoral neck shaft angle (NSA has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric, symptomatic vertebral (91, and distal forearm (67 fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm2: lumbar spine, femoral neck, and total femur measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately, nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P=0.001, but larger in those with distal forearm fractures (129.8° versus 128.5°: P=0.01. Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  5. Dominance of pre-analytical over analytical variation for measurement of methadone and its main metabolite in postmortem femoral blood

    DEFF Research Database (Denmark)

    Linnet, Kristian; Johansen, Sys Stybe; Buchard, Anders

    2008-01-01

    On the basis of simultaneously sampled postmortem blood specimens from the left and right femoral veins the pre-analytical variation of methadone measurements was evaluated and compared to the analytical variation. The material consisted of a series of 27 duplicate samples from routine autopsy ca...... interval (+/-2CV(T)) for a postmortem measurement is largely determined by the pre-analytical component of variation. This should be kept in mind when judging on the uncertainty of postmortem measurement results....

  6. Osteoid Osteoma of the Femoral Neck in Athletes: Two Case Reports Differentiating From Femoral Neck Stress Injuries.

    Science.gov (United States)

    Cordova, Christopher B; Dembowski, Scott C; Johnson, Michael R; Combs, John J; Svoboda, Steven J

    2016-01-01

    The diagnosis of an intra-articular osteoid osteoma can be a challenging and lengthy process, with reports of delayed diagnosis of greater than 2 years. In the young, athletic patient with an atraumatic onset of groin pain, an overuse injury or muscle strain is the most likely etiology. However, an overuse injury of femoral neck stress fracture must be identified because of the potentially disastrous outcome of fracture completion. The similar clinical presentation of a femoral neck stress fracture and intra-articular osteoid osteoma of the femoral neck can further delay the diagnosis of the osteoid osteoma. In a patient with these differential diagnoses that do not improve with a period of nonweightbearing activity, a more intensive workup must ensue. The purpose of this case report is to describe the initial presentations, subsequent follow-up, and imaging findings leading to the diagnosis of osteoid osteoma as well as to differentiate an osteoid osteoma from femoral neck stress injuries.

  7. Gait abnormalities following slipped capital femoral epiphysis.

    Science.gov (United States)

    Song, Kit M; Halliday, Suzanne; Reilly, Chris; Keezel, William

    2004-01-01

    The authors evaluated 30 subjects with treated unilateral slipped capital femoral epiphysis and a range of severity from mild to severe to characterize gait and strength abnormalities using instrumented three-dimensional gait analysis and isokinetic muscle testing. For slip angles less than 30 degrees, kinematic, kinetic, and strength variables were not significantly different from age- and weight-matched controls. For moderate to severe slips, as slip angle increased, passive hip flexion, hip abduction, and internal rotation in the flexed and extended positions decreased significantly. Persistent pelvic obliquity, medial lateral trunk sway, and trunk obliquity in stance increased, as did extension, adduction, and external rotation during gait. Gait velocity and step length decreased with increased amount of time spent in double limb stance. Hip abductor moment, hip extension moment, knee flexion moment, and ankle dorsiflexion moment were all decreased on the involved side. Hip and knee strength also decreased with increasing slip severity. All of these changes were present on the affected and to a lesser degree the unaffected side. Body center of mass translation or pelvic obliquity in mid-stance greater than one standard deviation above normal correlated well with the impression of compensated or uncompensated Trendelenburg gait.

  8. THE ENDO-EXO-FEMORAL PROSTHESIS

    Directory of Open Access Journals (Sweden)

    H. Aschoff

    2011-01-01

    Full Text Available Patients with above knee amputation (AKA face many challenges to mobility including difficulty with socket fit and fatigue due to high energy consumption. The aim of the Endo-Exo-Femur Prosthesis (EEFP is to avoid problems at the interface between the sleeve of the socket-prosthesis and the soft tissue coat of the femur stump which often impedes an inconspicuous and harmonic gait. In 1999 we began using a transcutaneous, press-fit distal femoral intramedullary device whose most distal external aspect serves as a hard point for AKA prosthesis attachment. The bone guided prosthesis enables an advanced gait via osseoperception and leads to a decreased oxygen consumption of the patient. Thirty two patients underwent the procedure between 1999 and 2008. Their indication for surgery was persistent AKA prosthesis difficulties with a history of AKA for trauma. The paper presents the patient data regarding the design of the implant, the operative procedure, patient satisfaction, gait analysis and oxygen consumption.

  9. Reconstruction of femoral length from fragmentary femora

    Science.gov (United States)

    Offei, Eric Bekoe; Osabutey, Casmiel Kwabena

    2016-01-01

    The reconstruction of femoral length (FL) from fragmentary femora is an essential step in estimating stature from fragmentary skeletal remains in forensic investigations. While regression formulae for doing this have been suggested for several populations, such formulae have not been established for Ghanaian skeletal remains. This study, therefore, seeks to derive regression formulae for reconstruction of FL from fragmentary femora of skeletal samples obtained from Ghana. Six measurements (vertical head diameter, transverse head diameter, bicondylar breadth, epicondylar breadth, sub-trochanteric anterior-posterior diameter, and sub-trochanteric transverse diameter) were acquired from different anatomical portions of the femur and the relationship between each acquired measurement and FL was analyzed using linear regression. The results indicated significantly moderate-to-high correlations (r=0.580–0.818) between FL and each acquired measurement. The error estimates of the regression formulae were relatively low (i.e., standard error of estimate, 13.66–19.28 mm), suggesting that the discrepancies between actual and estimated stature were relatively low. Compared with other measurements, sub-trochanteric transverse diameter was the best estimate of FL. In the absence of a complete femur, the regression formulae based on the assessed measurements may be used to infer FL, from which stature can be estimated in forensic investigations. PMID:27722014

  10. Computer-assisted femoral head resurfacing.

    Science.gov (United States)

    Hodgson, Antony J; Inkpen, Kevin B; Shekhman, Mark; Anglin, Carolyn; Tonetti, Jerome; Masri, Bassam A; Duncan, Clive P; Garbuz, Donald S; Greidanus, Nelson V

    2005-01-01

    Femoral head resurfacing is re-emerging as a surgical option for younger patients who are not yet candidates for total hip replacement. However, this procedure is more difficult than total hip replacement, and the mechanical jigs typically used to align the implant produce significant variability in implant placement and take a significant amount of time to position properly. We propose that a computer-assisted surgical (CAS) technique could reduce implant variability with little or no increase in operative time. We describe a new CAS technique for this procedure and demonstrate in a cadaver study of five paired femurs that the CAS technique in the hands of a novice surgeon markedly reduced the varus/valgus variability of the implant relative to the pre-operative plan (2 degrees standard deviation for CAS versus 5 degrees for a mechanical jig operated by an expert surgeon). We also show that the mechanical jig resulted in significantly retroverted implant placement. There was no significant difference in operative time between the two techniques.

  11. Distal femoral extension osteotomy and patellar tendon advancement to treat persistent crouch gait in cerebral palsy.

    Science.gov (United States)

    Stout, Jean L; Gage, James R; Schwartz, Michael H; Novacheck, Tom F

    2008-11-01

    Hallmarks of a persistent crouched walking pattern exhibited by individuals with cerebral palsy usually include loss of an adequate plantar flexion/knee extension couple, hamstring and/or psoas tightness, or contracture in conjunction with quadriceps insufficiency. Traditional treatment addresses the muscle-tightness component, but not the contracture or the muscle insufficiency. This study was performed to evaluate the effectiveness of distal femoral extension osteotomy and/or patellar tendon advancement in the treatment of crouch gait in patients with cerebral palsy. A retrospective, nonrandomized, repeated-measures design was used. Individuals with a diagnosis of cerebral palsy were included if they had had (1) a distal femoral extension osteotomy in combination with a distal patellar tendon advancement (thirty-three patients), (2) a distal femoral extension osteotomy without patellar tendon advancement (sixteen), or (3) a distal patellar tendon advancement only (twenty-four). All subjects were evaluated with preoperative and postoperative gait analysis. Gait, radiographic, strength, and functional measures were included in the analysis to assess changes in knee function. Seventy-three individuals met the criteria for inclusion. A single side was chosen for the analysis of each subject. Ninety percent of the subjects had additional, concurrent surgery. Improvements were noted in the index assessing the level of gait pathology and in functional variables across all groups, and pain was consistently decreased. All preoperative stress fractures healed. Strength levels were maintained across all groups. The Koshino index of patellar height improved from 1.4 to -2.3 in the group treated with patellar tendon advancement only and from 1.5 to -2.9 in the group treated with both osteotomy and tendon advancement. The range of knee flexion improved an average of 15 degrees to 20 degrees, and stance-phase knee flexion was restored to the typical range (9 degrees to 10

  12. Aneurisma da veia femoral simulando uma hérnia inguinal Femoral vein aneurysm simulating an inguinal hernia

    Directory of Open Access Journals (Sweden)

    Victor Assad Buffara-Jr

    2009-12-01

    Full Text Available INTRODUÇÃO: Somente seis casos de aneurismas da veia femoral simulando hérnia inguinal foram descritos na literatura. RELATO DO CASO: Um caso de aneurisma da veia femoral comum direita que simulava uma hérnia inguinal é descrito em jovem de 19 anos de idade com uma massa dolorosa de consistência mole na região inguinal direita de seis meses de duração. Durante a consulta médica, o paciente morreu durante em episódio de convulsão generalizada. Na necropsia, tromboembolismo pulmonar maciço e um aneurisma da veia femoral comum de 8x8x7 cm com trombos foram diagnosticados.BACKGROUND: Only six cases of femoral vein aneurysm are related on medical literature. CASE REPORT: A case of a right common femoral vein aneurysm simulating an inguinal hernia in a 19 year-old male. He had a soft and painful mass in the right inguinal area of six months of duration. At medical consultation, the patient died during a generalized convulsive episode. At necropsy, massive pulmonary thromboembolism and an 8x8x7 cm common femoral vein aneurysm with thrombus were recognized.

  13. Policy on use of foreign funds for western development to be loosened further%中国进一步放宽西部开发利用外资的政策

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ China has recently published the 11th Five-Year Plan on Development of the Western Area. A very important condition for continuous and fast progress for western development in China is to raise the opening level to the outside in the region, and the country will further loosen the policy on utilisation of foreign funds.

  14. A CADAVERIC STUDY OF VARIATIONS IN THE ORIGIN OF LATERAL CIRCUMFLEX FEMORAL ARTERY

    Directory of Open Access Journals (Sweden)

    Apurva Pradipkumar Darji

    2015-12-01

    Full Text Available Introduction: The lateral circumflex femoral artery is a branch of the profunda femoris artery, which is the largest branch of femoral artery. The knowledge of origin and branching patterns of the lateral circumflex femoral artery is valuable for various surgeries and clinical procedures. Objectives: To determine mode of origin of lateral circumflex femoral artery and to determine the distance of origin of lateral circumflex femoral artery from the origin of profunda femoris artery and from mid-inguinal point. Materials and Method: 130 femoral triangles were studied and various measurements were noted and analysed from the department of anatomy of various Medical colleges of Gujarat. Result and conclusion: The lateral circumflex femoral artery originated from profunda femoris artery in 119 cases and from femoral artery in 11 cases. In most of the cases, the distance of origin of lateral circumflex femoral artery from the origin of profunda femoris artery was ranging from 11 to 40 mm on both the sides.

  15. Surgical outcome of proximal femoral fractures using proximal femoral - locking compression plate

    Directory of Open Access Journals (Sweden)

    Prakash A. Sasnur

    2015-07-01

    Full Text Available Introduction: Proximal femoral fractures are complex fractures following devastating injuries in young and elderly population. Despite marked improvement in implant design, surgical technique and patient care these fractures are associated with high incidence of implant failure, refracture and varus collapse. Intramedullary nails are technically demanding and associated with high re-operation rates. The study was done to evaluate the outcome of proximal femoral fractures treated with proximal femur locking compression plate (PF-LCP. Methods: This study is conducted at Al Ameen Medical College and Hospital, Bijapur during the period Jan 2012 to March 2014.Pertrochanteric fractures especially unstable intertrochanteric & subtrochanteric fractures were included. Technical difficulties with the implant and operating time were quantified. Union of fracture site and implant related complications were followed up clinically and radiological. The Harris Hip Score was used to evaluate the functional outcome. Results: Thirty-two patients were available for final evaluation with average age of 55.4 years. The average operation time was 1 hour and 35 minutes with mean blood loss of 180ml. Union was achieved in all the cases with an average time of 17 weeks. Complications included one case of delayed union and three cases of varus collapse. Conclusion: PF-LCP achieves anatomical reduction and stable fixation with higher union rate and fewer complications.

  16. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  17. Structural and functional studies of bioobjects prepared from femoral heads

    Energy Technology Data Exchange (ETDEWEB)

    Kirilova, I. A., E-mail: IKirilova@niito.ru; Podorozhnaya, V. T., E-mail: VPodorognaya@niito.ru [Research Institute of Traumatology and Orthopedics n.a. Ya.L. Tsivyan, 17, Frunze, Novosibirsk, 630091 (Russian Federation); Sharkeev, Yu. P., E-mail: sharkeev@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation); National Research Tomsk Polytechnic University, 30, Lenin Avenue, Tomsk, 634050 (Russian Federation); Popova, K. S., E-mail: kseniya@ispms.tsc.ru; Uvarkin, P. V., E-mail: uvarkin@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634021 (Russian Federation)

    2015-11-17

    Results of examination of physicomechanical characteristics of samples of medial femoral head cuts are presented. The samples of medial femoral head cuts resected in 6 patients with coxarthrosis in primary endoprosthetic replacement of a coxofemoral joint have been tested for micro- and nanohardness. Young’s modulus and elemental composition of bone tissue have been investigated. To estimate the architectonics of cancellous tissue of the femoral head, adjacent cuts of the same patient have been analyzed. The porosity of bone tissue was estimated from macroscopic images obtained using macrophotography. The total porosity is calculated as the ratio of the total length of straight line segments overlapping pores to the total length of secants. A three-point bending test of the samples has shown that their strength changed from 0.187 to 1.650 MPa and their elasticity modulus changes from 1.69 to 8.15 MPa. The microhardness of the samples changes in the range 220–265 MPa and the average microhardness of medial femoral head cuts is 240 MPa. The elemental composition of medial femoral head cuts is represented by basic Ca, P, O, Na and Mg elements as well as by Sn, S, Fe, Cr, and C in microamounts. The atomic Ca to P ratio for bone tissue is 1.55. It is revealed that pores of the upper part of the femoral head have a more regular shape and in the lower part they are more elongated along the cut and occupy a larger volume. The lower part of the femoral head has a higher porosity (39 and 33%) than the upper part (34 and 30%). The total porosity of all samples does not exceed 37%.

  18. [Femoral artery pseudoaneurysms encountered in orthopedics and traumatology].

    Science.gov (United States)

    Raherinantenaina, F; Rajaonanahary, T M A; Rakoto Ratsimba, H N

    2015-12-01

    Most published articles regarding orthopedic- and trauma-related femoral artery pseudoaneurysms (FAPs) are case reports in English. Reported cases are often associated with a literature review but actually provide little robust data. We wanted to summarize the current knowledge on diagnostic and therapeutic features of these FAPs. A new case of superficial FAP is described followed by a review of the literature. A bibliographic search was performed online (PubMed, ScinceDirect) from 1964 to 2015 using the descriptors "traumatic femoral pseudoaneurysm, orthopedic surgery, osteochondroma". A total of 64 cases of FAPs was analyzed. There were 50 men with an average age of 40.72±26.45 years old. The most common clinical presentation was painful swelling (34%). Arteriography was the commonest radiological investigation used (63%). The main etiologies were orthopedic injuries (47%), surgery of the upper thigh (30%) and femoral osteochondromas (23%). Arterial injuries included superficial femoral (47%) and profunda femoris artery (50%). The treatment was open surgery (56%) or endovascular repair (36%). Deep femoral artery and its branches were embolized (47%) or ligated (38%). Endovascular stenting was performed in 30% of posttraumatic FAPs. All FAPs relating to osteochondromas were repaired surgically. Postoperative courses were uneventful in 95% of patients. Endovascular embolization is preferred in management of postsurgical FAPs which have usually involved the deep femoral artery. Endovascular stenting graft may be proposed for posttraumatic FAPs, for which the superficial femoral trunk is the most often involved vessel. Surgical repair should be performed when endovascular stenting graft is not feasible. Surgical repair is mandatory for all FAPs secondary to traumatic exostoses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Femoral neck radiography: effect of flexion on visualization

    Energy Technology Data Exchange (ETDEWEB)

    Garry, S.C. [Univ. of Alberta, Dept. of Radiology and Diagnostic Imaging, Walter C Mackenzie Health Sciences Centre, Edmonton, Alberta (Canada); Jhangri, G.S. [Univ. of Alberta, Dept. Public Health Sciences, Edmonton, Alberta (Canada); Lambert, R.G.W. [Univ. of Alberta, Dept.of Radiology and Diagnostic Imaging, Walter C Mackenzie Health Sciences Centre, Edmonton, Alberta (Canada)]. E-mail: rglamber@cha.ab.ca

    2005-06-15

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15{sup o} and flexion in 10{sup o} increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0{sup o} and 20{sup o} flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation ({rho} < 0.05). Visualization of the femoral neck in the extended position progressively deteriorated from 15{sup o} internal rotation to 30{sup o} external rotation ({rho} <0.01). However, when 20{sup o} flexion was applied to bones in external rotation, visualization significantly improved at 15{sup o} ({rho} <0.05) and 30{sup o} ({rho} <0.01). Flexion of the externally rotated femur can bring the femoral neck into horizontal alignment, and a relatively small amount (20{sup o}) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg. (author)

  20. Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Selahattin Ozyurek

    2015-07-01

    Full Text Available Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2 with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative distal femur fracture at a range of time intervals (1,2 intraoperative intra-articular distal femur fracture is a unique entity.However, we believe that some important additional observations seem necessary to be contributed through this study. In this article, the authors stated that, to the best of their knowledge, there is no other case report in the literature introducing a femoral condyle fracture during arthroscopic ACL reconstruction or revision reconstruction. Nevertheless, we would like to call the attention of the readers to the fact that that the literature contains one additional case report re‌porting on intraoperative distal femoral coronal plane (Hoffa fracture during primary ACL reconstruction (2. Werner BC and Miller MD presented of case report of an intraoperative distal femoral coronal plane (Hoffa fracture that occurred during independent femoral tunnel drilling and dilation in a primary ACL reconstruction. As in the their case, this type of fracture can occur with appropriately placed femoral tunnels, but the risk can increase with larger graft diameters in patients with smaller lateral femoral condyles The patient was treated with open reduction and internal fixation, without compromise of graft stability and with good recovery of function. We believe that tailoring graft size to the size of the patient is important to prevent similar adverse events.

  1. Peri-prosthetic femoral fractures of hip or knee arthroplasty. Analysis of 34 cases and a review of Spanish series in the last 20 years.

    Science.gov (United States)

    Gracia-Ochoa, M; Miranda, I; Orenga, S; Hurtado-Oliver, V; Sendra, F; Roselló-Añón, A

    2016-01-01

    To evaluate peri-prosthetic femoral fractures by analysing type of patient, treatment and outcomes, and to compare them with Spanish series published in the last 20 years. A retrospective review of the medical records of patients with peri-prosthetic femoral fractures treated in our hospital from 2010 to 2014, and telephone survey on the current status. A total of 34 peri-prosthetic femoral fractures were analysed, 20 in hip arthroplasty and 14 in knee arthroplasty. The mean age of the patients was 79.9 years, and 91% had previous comorbidity, with up to 36% having at least 3 prior systemic diseases. Mean hospital stay was 8.7 days, and was higher in surgically-treated than in conservative-treated patients. The majority (60.6%) of patients had complications, and mortality was 18%. Functional status was not regained in 61.5% of patients, and pain was higher in hip than in knee arthroplasty. Peri-prosthetic femoral fractures are increasing in frequency. This is due to the increasing number of arthroplasties performed and also to the increasing age of these patients. Treatment of these fractures is complex because of the presence of an arthroplasty component, low bone quality, and comorbidity of the patients. Peri-prosthetic femoral fractures impair quality of life. They need individualised treatment, and have frequent complications and mortality. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Infectious prosthetic hip joint loosening: bacterial species involved in its aetiology and their antibiotic resistance profiles against antibiotics recommended for the therapy of implant-associated infections.

    Science.gov (United States)

    Bogut, Agnieszka; Niedźwiadek, Justyna; Strzelec-Nowak, Dagmara; Blacha, Jan; Mazurkiewicz, Tomasz; Marczyński, Wojciech; Kozioł-Montewka, Maria

    2014-04-01

    Reliable microbiological diagnosis along with surgery and prolonged antibiotic therapy are key elements in the management of prosthetic-joint infections (PJIs). The purpose of this study was to characterize antibiotic resistance profiles of bacteria involved in the aetiology of PJIs. A total of 33 bacterial isolates cultured from 31 patients undergoing exchange of total hip prostheses were analyzed. The diagnostic approach toward isolation of prosthesis- associated microorganisms included sonication of retrieved implants and conventional cultures of periprosthetic tissues and synovial fluid. The in vitro resistance profiles of bacterial isolates were determined in relation to antibiotics recommended for the therapy of PJIs using the disc diffusion method, E-tests(®) and broth microdilution system. Coagulase-negative staphylococci (CNS) were predominant microorganisms followed by Staphylococcus aureus, Enterobacter cloacae, Streptococcus mitis, and Propionibacterium acnes. Twenty out of 30 and 12 out of 30 staphylococcal isolates were methicillin- and multi-drug resistant, respectively. Only two isolates were rifampicinresistant. All staphylococci were susceptible to glycopeptides and linezolid. This paper stresses the pathogenic role of staphylococci in patients suffering from implant loosening and reports high methicillin- and multidrug-resistance rates in these bacteria. Hence, antimicrobial susceptibility tests of individual bacterial isolates must always be performed to guide selection of the optimal therapeutic option.

  3. Treatment of subtrochanteric femoral fractures with proximal femoral nail antirotation%股骨近端防旋髓内钉治疗股骨转子下骨折

    Institute of Scientific and Technical Information of China (English)

    赵海生; 徐耀增; 王贵贤; 李荣群

    2013-01-01

    背景:髓内钉具有优良的力学承载性能,提高了骨与内固定的整体稳定性,减少了骨折畸形愈合和内固定失败的发生率。股骨转子下骨折的内固定治疗对内植物的要求较高,因此在内植物的选择上仍存在很多争议。目的:评价股骨近端防旋髓内钉治疗股骨转子下骨折的临床疗效。  方法:回顾性分析苏州大学附属第一医院2006年6月至2011年11月采用股骨近端防旋髓内钉内固定治疗股骨转子下骨折患者17例的病例资料。其中股骨转子下骨折合并转子间骨折9例(Seinsheimer分型Ⅴ型),股骨转子下骨折(Seinsheimer分型ⅡB 2例,Ⅲ B 1例,Ⅳ4例)累及股骨干骨折7例,Seinsheimer分型Ⅴ型同时累及同侧股骨干骨折1例。受伤原因:高能量损伤16例,低能量损伤1例。记录固定时间、固定时出血量、骨折愈合时间及患肢功能恢复情况。  结果与结论:固定后随访8-24个月,平均16.2个月。固定后X射线片示骨折愈合时间平均5.4个月。固定后X射线片示所有患者骨折复位良好,转子下骨折、转子间及股骨干骨折均愈合,未出现骨折移位、内固定松动及髋内翻畸形,固定时仅有1例患者出现插钉困难。固定后患者Harris髋关节功能评分优良率为88.2%。结果证实,股骨近端防旋髓内钉本身设计合理,其防旋刀片对骨折端具有抗旋转和成角稳定性,疗效较好,安全可靠,是治疗股骨转子下骨折较理想的内固定物。%Postoperative X-ray films showed that the fracture healing time was averagely 5.4 months. Al of the fractures were recovered wel that subtrochanteric fractures, intertrochanteric fractures and femoral shaft fractures were al healed. There was no fracture displacement, internal fixation loosening and varus deformity. Only one case showed difficulties in nail insertion. Excellence rate of Harris hip functional scores was 88

  4. Valgus Slipped Capital Femoral Epiphysis in Patient with Hypopituitarism

    Science.gov (United States)

    Fujiwara, Yasuhiro; Hayashida, Tatsuro; Murakami, Koji; Makio, Satoshi; Shimizu, Yuichi; Oka, Yoshinobu; Kim, Wook-Choel; Ogura, Taku; Kubo, Toshikazu

    2017-01-01

    Slipped capital femoral epiphysis (SCFE) is a common disease of adolescent and the epiphysis is positioned more posteromedially in relation to the femoral neck shaft with varus SCFE; however, posterolateral displacement of the capital epiphysis, valgus SCFE, occurs less frequently. We report a case of valgus SCFE in a 17-year-old boy with hypopituitarism. After falling down, he experienced difficulty in walking. The radiographs were inconclusive; however three-dimensional computed tomography images showed lateral displacement of the epiphysis on the right femoral head. Valgus SCFE was diagnosed. The patient underwent in situ pinning of both sides. In situ pinning on the left side was performed as a prophylactic pinning because of endocrine abnormalities. At the 1-year follow-up, he could walk without any difficulty and there were no signs of pain. The epiphysis is commonly positioned more posteromedially in relation to the femoral neck shaft with most SCFE, but, in this case, the epiphysis slipped laterally. Differential diagnosis included femoral neck fracture (Delbet-Colonna type 1); however, this was less likely due to the absence of other clinical signs. Therefore, we diagnosed the patient as SCFE. When children complain of leg pain and limp, valgus SCFE that may not be visualized on anteroposterior radiographs needs to be considered. PMID:28154765

  5. Valgus Slipped Capital Femoral Epiphysis in Patient with Hypopituitarism

    Directory of Open Access Journals (Sweden)

    Yoshihiro Kotoura

    2017-01-01

    Full Text Available Slipped capital femoral epiphysis (SCFE is a common disease of adolescent and the epiphysis is positioned more posteromedially in relation to the femoral neck shaft with varus SCFE; however, posterolateral displacement of the capital epiphysis, valgus SCFE, occurs less frequently. We report a case of valgus SCFE in a 17-year-old boy with hypopituitarism. After falling down, he experienced difficulty in walking. The radiographs were inconclusive; however three-dimensional computed tomography images showed lateral displacement of the epiphysis on the right femoral head. Valgus SCFE was diagnosed. The patient underwent in situ pinning of both sides. In situ pinning on the left side was performed as a prophylactic pinning because of endocrine abnormalities. At the 1-year follow-up, he could walk without any difficulty and there were no signs of pain. The epiphysis is commonly positioned more posteromedially in relation to the femoral neck shaft with most SCFE, but, in this case, the epiphysis slipped laterally. Differential diagnosis included femoral neck fracture (Delbet-Colonna type 1; however, this was less likely due to the absence of other clinical signs. Therefore, we diagnosed the patient as SCFE. When children complain of leg pain and limp, valgus SCFE that may not be visualized on anteroposterior radiographs needs to be considered.

  6. Avascular necrosis of the femoral head in HIV infected patients

    Directory of Open Access Journals (Sweden)

    Marcos Almeida Matos

    Full Text Available Avascular necrosis (AVN of the femoral head is an emerging complication in HIV infected patients. It has been suggested that the increased incidence of AVN in this population may be caused by an increased prevalence of predisposing factors for osteonecrosis, including protease inhibitors, hyperlipidemia, corticosteroid use, alcohol and intravenous drug abuse. The aim of this study was to assess the risk factors for avascular necrosis developing in the femoral head of HIV infected individuals. This study consisted of meta-analysis of the secondary data extracted from current literature. The selected articles allowed two study groups to be drawn up for comparison. Group 1 comprised 324 individuals infected by the HIV virus, who did not present femoral head AVN. Group 2 comprised 32 HIV positive patients, who presented femoral head AVN. The parameters used for analysis were as follows: age, gender, sexual preference, use of intravenous drugs, time of diagnosis, CD4+ cell count, use of antiretroviral agents and duration, serum cholesterol and serum triglycerides. The present study found a statistically significant association between hypertriglyceridemia, hypercholesterolemia, sexual preference and intravenous drug abuse. The authors concluded that femoral head osteonecrosis is associated with hyperlipidemia (hypercholesterolemia and hypertriglyceridemia and intravenous drug abuse. This study supports the hypothesis that protease inhibitors play a role in the development of osteonecrosis through a tendency to cause hyperlipidemia.

  7. Reconstruction plate fixation of subtrochanteric femoral fractures in children.

    Science.gov (United States)

    El-Sayed, Moustafa; Abulsaad, Mazen; El-Hadidi, Mahmoud; El-Adl, Wael; El-Batouty, Magdy

    2007-08-01

    Pediatric subtrochanteric femoral fractures are rare and have received limited attention in the literature Treatment is controversial. Different treatment options are used: skin traction, 90/90 skeletal traction, spica casting, cast bracing, internal fixation and external fixation. The aim of this study is to present our results with internal fixation of subtrochanteric femoral fractures in children using a reconstruction plate. Between 2000 and 2004, eighteen patients with closed subtrochanteric femoral fractures were treated in the Mansoura Emergency Hospital. The average age at the time of injury was 8.2 years (range 5.3 years to 11.5 years). Pathological fractures and fractures associated with neuromuscular diseases were excluded from this study. Eight patients had head injuries and/or multiple injuries. In all cases a single 4.5 mm contoured reconstruction plate was used and a 6.5 mm cancellous screw was inserted through the plate into the femoral neck. Average follow-up was 38 months (range, 12 to 47 months). All fractures united with anatomical alignment within an average of 8 weeks (range 6 to 12 weeks). There were no deep infections and no significant limb length discrepancies. At the latest follow-up, no patient had any restriction of activities. Internal fixation with a reconstruction plate appears as a good treatment option for children with subtrochanteric femoral fractures.

  8. Avascular necrosis of the femoral head in HIV infected patients

    Directory of Open Access Journals (Sweden)

    Marcos Almeida Matos

    2007-02-01

    Full Text Available Avascular necrosis (AVN of the femoral head is an emerging complication in HIV infected patients. It has been suggested that the increased incidence of AVN in this population may be caused by an increased prevalence of predisposing factors for osteonecrosis, including protease inhibitors, hyperlipidemia, corticosteroid use, alcohol and intravenous drug abuse. The aim of this study was to assess the risk factors for avascular necrosis developing in the femoral head of HIV infected individuals. This study consisted of meta-analysis of the secondary data extracted from current literature. The selected articles allowed two study groups to be drawn up for comparison. Group 1 comprised 324 individuals infected by the HIV virus, who did not present femoral head AVN. Group 2 comprised 32 HIV positive patients, who presented femoral head AVN. The parameters used for analysis were as follows: age, gender, sexual preference, use of intravenous drugs, time of diagnosis, CD4+ cell count, use of antiretroviral agents and duration, serum cholesterol and serum triglycerides. The present study found a statistically significant association between hypertriglyceridemia, hypercholesterolemia, sexual preference and intravenous drug abuse. The authors concluded that femoral head osteonecrosis is associated with hyperlipidemia (hypercholesterolemia and hypertriglyceridemia and intravenous drug abuse. This study supports the hypothesis that protease inhibitors play a role in the development of osteonecrosis through a tendency to cause hyperlipidemia.

  9. Numerical simulation of blood flow in femoral perfusion: comparison between side-armed femoral artery perfusion and direct femoral artery perfusion.

    Science.gov (United States)

    Kitamura, Shingo; Shirota, Minori; Fukuda, Wakako; Inamura, Takao; Fukuda, Ikuo

    2016-12-01

    Computational numerical analysis was performed to elucidate the flow dynamics of femoral artery perfusion. Numerical simulation of blood flow was performed from the right femoral artery in an aortic model. An incompressible Navier-Stokes equation and continuity equation were solved using computed flow dynamics software. Three different perfusion models were analyzed: a 4.0-mm cannula (outer diameter 15 French size), a 5.2-mm cannula (18 French size) and an 8-mm prosthetic graft. The cannula was inserted parallel to the femoral artery, while the graft was anastomosed perpendicular to the femoral artery. Shear stress was highest with the 4-mm cannula (172 Pa) followed by the graft (127 Pa) and the 5.2-mm cannula (99 Pa). The cannula exit velocity was high, even when the 5.2-mm cannula was used. Although side-armed perfusion with an 8-mm graft generated a high shear stress area near the point of anastomosis, flow velocity at the external iliac artery was decreased. The jet speed decreased due to the Coanda effect caused by the recirculation behind sudden expansion of diameter, and the flow velocity maintains a constant speed after the reattachment length of the flow. This study showed that iliac artery shear stress was lower with the 5.2-mm cannula than with the 4-mm cannula when used for femoral perfusion. Side-armed graft perfusion generates a high shear stress area around the anastomotic site, but flow velocity in the iliac artery is slower in the graft model than in the 5.2-mm cannula model.

  10. Microstructural features in fractured high nitrogen stainless steel hip prostheses: a retrieval study of polished, tapered femoral stems.

    Science.gov (United States)

    Swarts, Eric; Kop, Alan; Jones, Noel; Keogh, Cathie; Miller, Susan; Yates, Piers

    2008-03-01

    Six fractured high nitrogen stainless steel (HNSS), polished, tapered hip stems have been reviewed for analysis. Clinical data suggests that poor proximal support (loosening), varus positioning, and canal morphology are implicated in the failure of these stems. Metallurgical assessment reveals a number of microstructural deficiencies contributing to failure. Of significance is poor grain homogeneity and larger grain size near the surface of the fractured stems. It appears some polished, tapered HNSS stems are at risk when combinations of these clinical and metallurgical features occur. As the control of grain size, microstructural uniformity, and inclusion content are critical for optimum mechanical performance, it is important the manufacturers review processing methods to further minimize the risk of component failure.

  11. A Modified Ogata-Goldsand Technique for Simplified Intraoperative Measurement of Femoral Version.

    Science.gov (United States)

    Morris, William Z; Henry, Havalee; Liu, Raymond W; Streit, Jonathan J; Grant, Richard E; Cooperman, Daniel R

    2015-09-01

    Femoral anteversion can be difficult to determine intraoperatively, particularly in cases with complicated deformity. Although biplanar methodology exists for measuring femoral anteversion, the measurements are generally based on the proximal femur, without consideration for the femoral bow. We directly measured femoral version in 70 mature cadaveric femora. Using the standard Ogata-Goldsand approach, femoral version was geometrically calculated after measuring apparent neck-shaft angle and the β-angle, which is the angle between the femoral neck and proximal femoral shaft on a direct lateral view. We then used a modified β-angle, measured between the femoral neck and a line representing the entire femur. Mean anatomic femoral anteversion was 20±11 degrees. Mean calculated femoral version using the standard Ogata-Goldsand technique was 32±13 degrees, whereas mean calculated femoral version using the modified Ogata-Goldsand technique was 22±12 degrees. Repeated measures ANOVA analysis found an overall statistically significant difference between the 3 groups (POgata-Goldsand technique (POgata-Goldsand technique (P=0.76). Standard biplanar imaging techniques do not account for the femoral bow and can significantly overestimate femoral anteversion. If a line is drawn from the posterior femoral condyles to the posterior aspect of the greater trochanter, femoral anteversion is better approximated. Intraoperatively, we obtain this line by positioning a marker over the skin under fluoroscopy. Clinically, if one aims for a modified β-angle of 5 degrees, a postosteotomy anteroposterior radiograph is no longer necessary, given the knowledge that with apparent neck-shaft angles ranging from 115 to 155 degrees, version will lie within a generally accepted range between 2 and 11 degrees. In complex operative cases where imaging is desired to measure intraoperative femoral version, we recommend a modified and simplified lateral view measurement technique, which improves

  12. Clinical and Radiographic Evaluation of a Commercially Pure Cancellous-Structured Titanium Press Fit Total Hip Prosthetic Stem: Ten-Year Followup of the “Natural Hip” Femoral Stem

    Directory of Open Access Journals (Sweden)

    Thomas B. Pace

    2014-01-01

    Full Text Available This study evaluates the outcomes of 92 hip arthroplasties using a press fit, tapered, split tip, proximally porous ingrowth (CSTi femoral stem (Zimmer Natural Hip in consecutive hip arthroplasty patients followed for an average of ten years postoperatively (range 5–16 years. Patients were functionally and radiographically evaluated using Harris Hip Scores and plain radiographs assessing postarthroplasty groin or thigh pain and radiographic signs of stem subsidence, proximal femoral fixation, stress shielding, and related calcar resorption. At followup of 5–10 years, the incidence of groin pain and thigh pain was 9.1% and 3.6%, respectively. This incidence improved over time. Beyond 10 years of followup, groin pain was 2.7% and thigh pain zero. In 89% of cases, there was solid contact between the calcar and the undersurface of the stem collar. Five cases were revised for instability (5.4%. The Harris Hip Scores and the incidence of thigh or groin pain were very favorable compared to other reported press fit total hip arthroplasty stems and not significantly different across a broad age range. There were no cases of stem loosening of failure of bony ingrowth into the stem.

  13. Survivorship Analysis of Eighty Revised Hip Arthroplasties With the Impaction Grafting Technique Using Whole Femoral Head Allografts With the Articular Cartilage.

    Science.gov (United States)

    Fadulelmola, Ahmed; Drampalos, Efstathios; Hodgkinson, John; Hemmady, Mukesh

    2017-06-01

    Acetabular impaction bone grafting aims to restore anatomy in hip revision surgery. This is an effective but expensive and time-consuming technique. Usually, the articular cartilage is removed from the femoral head allograft. We aimed to reproduce the same results retaining the cartilage of the allograft. Eighty acetabular revisions using impacted morselized bone graft retaining the articular cartilage and a cemented cup were studied retrospectively. Six were lost during follow-up. The mean follow-up was 6.5 years (range 1-13). Clinical and radiological assessment was made using the Oxford Hip Score, Hodgkinson's criteria for socket loosening, and the Gie classification for evaluation of allograft incorporation. Sixty-three sockets (85.1%) were considered radiologically stable (type 0, 1, and 2 demarcations), 8 (10.8%) were radiologically loose (type 3), and 3 (4.1%) presented with migration. Fifty-one (68.9%) cases showed good trabecular remodeling (grade 3), 20 (27%) showed trabecular incorporation (grade 2), and 3 (4.1%) showed poor allograft incorporation. Mean preoperative hip score was 43 and postoperative score was 28. Six (8.1%) cases presented heterotopic ossification around the revised implants, 2 patients (2.7%) had periprosthetic fractures, and 4 (5.4%) had dislocations. The Kaplan-Meier survivorship at a mean of 6.5 years with revision of the cup for any reason was 95.9% (95% confidence interval 5.6-7.5). The mid-term results of our technique are promising. Particularly when the supply of fresh-frozen allografts and surgical time is limited, using whole femoral head with articular cartilage is both safe and effective. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Comparison of steady state femoral head penetration rates between two highly cross-linked polyethylenes in total hip arthroplasty.

    Science.gov (United States)

    Whittaker, John-Paul; Charron, Kory D; McCalden, Richard W; Macdonald, Steven J; Bourne, Robert B

    2010-08-01

    Given that the manufacture of highly cross-linked polyethylene (HXLPE) is not standardized, the behavior of these materials may vary. Our study compares minimum 5-year steady state femoral head penetration rates using the Martell method, in 2 HXPLEs produced by different manufacturers. Patients received a primary hip arthroplasty using an uncemented acetabular component with an HXLPE liner and a 28-mm femoral head. Forty-seven patients in group A received an HXLPE liner (Reflection XLPE, Smith and Nephew Inc, Memphis, Tenn), and 36 patients in group B received a different HXLPE liner (Longevity, Zimmer Inc, Warsaw, Ind). Average follow-up was 6.42 years in group A and 7.64 years in group B. The steady state head penetration rates were not significantly (P > .05) different between the HXPLE groups over the midterm with 0.026 mm/y and 0.025 mm/y in groups A and B, respectively.

  15. Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement: two-year results from a randomised study.

    Science.gov (United States)

    Penny, J O; Brixen, K; Varmarken, J E; Ovesen, O; Overgaard, S

    2012-08-01

    It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised into two groups to receive either a resurfacing or a THR and were followed for two years. One patient's resurfacing subsequently failed, leaving 19 patients in each group. Resurfaced replacements maintained proximal femoral BMD and, compared with THR, had an increased bone mineral density in Gruen zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95% confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6% (95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD of the medial femoral neck and increased that in the lateral zones between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6). On the acetabular side, BMD was similar in every zone at each point in time. The mean BMD of all acetabular regions in the resurfaced group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863). A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8 to 9.0) of BMD was found above the acetabular component in W1 and 10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial to the implant in W2 for resurfaced replacements and THRs respectively. Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to 12.7) in W3 but the BMD inferior to the acetabular component was maintained in both groups. These results suggest that the ability of a resurfacing hip replacement to preserve BMD only applies to the femoral side.

  16. A case report of missed femoral neck stress fracture

    Directory of Open Access Journals (Sweden)

    Onibere Oruaro Adebayo

    2015-01-01

    Full Text Available Femoral neck stress fracture (FNSF is an uncommon but potentially serious orthopaedic problem. This is a case report on missed femoral neck stress fracture in a 62-year-old female who was initially treated as early-onset coxarthrosis. She later presented to us with a displaced intra-capsular neck of left femur fracture and underwent total hip replacement. This case illustrates that causes other than osteoarthritis should be taken into consideration in patients presenting with anterior hip pain where symptoms are disproportionate to clinical and radiological findings. More advanced investigations such as MRI scan or regular follow up with plain radiographs should be performed. A delay in diagnosis can lead to secondary displacement of the femoral neck stress fracture.

  17. Femoral arteriographic finding in acute ergotism: Report of A Case

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, H. S.; Lee, K. N.; Cha, S. B. [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1971-10-15

    A case of acute ergotism with angiographic demonstration of bilateral femoral artery involvement is reported. A 27-year-old married woman was admitted because of sudden onset of severe pain in both flanks and lower legs, followed by numbness and coldness of the skin on both legs. The attack occurred after the administration of ergot tartrate as postpartum care. Femoral arteriography was performed on 10th day of illness with the Seldinger technic. The femoral arteries were generally smaller in caliber than normal. There was no definite evidence of occlusive disease. Findings were more or less symmetrical and extended to lower legs where only fine branches were visualized. The final diagnosis was diffuse vasospasm due to acute ergotism with secondary occlusion of the arteries of lower leg bilaterally.

  18. Effect of femoral head size and surgical approach on risk of revision for dislocation after total hip arthroplasty.

    Science.gov (United States)

    Zijlstra, Wierd P; De Hartog, Bas; Van Steenbergen, Liza N; Scheurs, B Willem; Nelissen, Rob G H H

    2017-08-01

    Background and purpose - Recurrent dislocation is the commonest cause of early revision of a total hip arthropasty (THA). We examined the effect of femoral head size and surgical approach on revision rate for dislocation, and for other reasons, after total hip arthroplasty (THA). Patients and methods - We analyzed data on 166,231 primary THAs and 3,754 subsequent revision THAs performed between 2007 and 2015, registered in the Dutch Arthroplasty Register (LROI). Revision rate for dislocation, and for all other causes, were calculated by competing-risk analysis at 6-year follow-up. Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results - Posterolateral approach was associated with higher dislocation revision risk (HR =1) than straight lateral, anterolateral, and anterior approaches (HR =0.5-0.6). However, the risk of revision for all other reasons (especially stem loosening) was higher with anterior and anterolateral approaches (HR =1.2) and lowest with posterolateral approach (HR =1). For all approaches, 32-mm heads reduced the risk of revision for dislocation compared to 22- to 28-mm heads (HR =1 and 1.6, respectively), while the risk of revision for other causes remained unchanged. 36-mm heads increasingly reduced the risk of revision for dislocation but only with the posterolateral approach (HR =0.6), while the risk of revision for other reasons was unchanged. With the anterior approach, 36-mm heads increased the risk of revision for other reasons (HR =1.5). Interpretation - Compared to the posterolateral approach, direct anterior and anterolateral approaches reduce the risk of revision for dislocation, but at the cost of more stem revisions and other revisions. For all approaches, there is benefit in using 32-mm heads instead of 22- to 28-mm heads. For the posterolateral approach, 36-mm heads can safely further reduce the risk of revision for dislocation.

  19. Design and validation of automated femoral bone morphology measurements in cerebral palsy.

    Science.gov (United States)

    Park, Noyeol; Lee, Jehee; Sung, Ki Hyuk; Park, Moon Seok; Koo, Seungbum

    2014-04-01

    Accurate quantification of bone morphology is important for monitoring the progress of bony deformation in patients with cerebral palsy. The purpose of the study was to develop an automatic bone morphology measurement method using one or two radiographs. The study focused on four morphologic measurements-neck-shaft angle, femoral anteversion, shaft bowing angle, and neck length. Fifty-four three-dimensional (3D) geometrical femur models were generated from the computed tomography (CT) of cerebral palsy patients. Principal component analysis was performed on the combined data of geometrical femur models and manual measurements of the four morphologic measurements to generate a statistical femur model. The 3D-2D registration of the statistical femur model for radiography computes four morphological measurements of the femur in the radiographs automatically. The prediction performance was tested here by means of leave-one-out cross-validation and was quantified by the intraclass correlation coefficient (ICC) and by measuring the absolute differences between automatic prediction from two radiographs and manual measurements using original CT images. For the neck-shaft angle, femoral anteversion, shaft bowing angle, and neck length, the ICCs were 0.812, 0.960, 0.834, and 0.750, respectively, and the mean absolute differences were 2.52°, 2.85°, 0.92°, and 1.88 mm, respectively. Four important dimensions of the femur could be predicted from two views with very good agreement with manual measurements from CT and hip radiographs. The proposed method can help young patients avoid instances of large radiation exposure from CT, and their femoral deformities can be quantified robustly and effectively from one or two radiograph(s).

  20. Subchondral bone density distribution in the human femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Wright, David A.; Meguid, Michael; Lubovsky, Omri; Whyne, Cari M. [Sunnybrook Research Institute, Orthopaedic Biomechanics Laboratory, Toronto, Ontario (Canada)

    2012-06-15

    This study aims to quantitatively characterize the distribution of subchondral bone density across the human femoral head using a computed tomography derived measurement of bone density and a common reference coordinate system. Femoral head surfaces were created bilaterally for 30 patients (14 males, 16 females, mean age 67.2 years) through semi-automatic segmentation of reconstructed CT data and used to map bone density, by shrinking them into the subchondral bone and averaging the greyscale values (linearly related to bone density) within 5 mm of the articular surface. Density maps were then oriented with the center of the head at the origin, the femoral mechanical axis (FMA) aligned with the vertical, and the posterior condylar axis (PCA) aligned with the horizontal. Twelve regions were created by dividing the density maps into three concentric rings at increments of 30 from the horizontal, then splitting into four quadrants along the anterior-posterior and medial-lateral axes. Mean values for each region were compared using repeated measures ANOVA and a Bonferroni post hoc test, and side-to-side correlations were analyzed using a Pearson's correlation. The regions representing the medial side of the femoral head's superior portion were found to have significantly higher densities compared to other regions (p < 0.05). Significant side-to-side correlations were found for all regions (r {sup 2} = 0.81 to r {sup 2} = 0.16), with strong correlations for the highest density regions. Side-to-side differences in measured bone density were seen for two regions in the anterio-lateral portion of the femoral head (p < 0.05). The high correlation found between the left and right sides indicates that this tool may be useful for understanding 'normal' density patterns in hips affected by unilateral pathologies such as avascular necrosis, fracture, developmental dysplasia of the hip, Perthes disease, and slipped capital femoral head epiphysis. (orig.)

  1. Open femoral hernia repair: one skin incision for all

    Directory of Open Access Journals (Sweden)

    El-Masry Nabil S

    2009-11-01

    Full Text Available Abstract Background Femoral hernias are relatively uncommon, however they are the most common incarcerated abdominal hernia, with strangulation of a viscus carrying significant mortality. Classically three approaches are described to open femoral hernia repair: Lockwood's infra-inguinal, Lotheissen's trans-inguinal and McEvedy's high approach. Each approach describes a separate skin incision and dissection to access the femoral sac. The decision as to which approach to adopt, predominantly dependent on the suspicion of finding strangulated bowel, is often a difficult one and in our opinion an unnecessary one. Methods We propose a technique for open femoral hernia repair that involves a single skin incision 1 cm above the medial half of the inguinal ligament that allows all of the above approaches to the hernia sac depending on the operative findings. Thus the repair of simple femoral hernias can be performed from below the inguinal ligament. If found, inguinal hernias can be repaired. More importantly, resection of compromised bowel can be achieved by accessing the peritoneal cavity with division of the linea semilunaris 4 cm above the inguinal ligament. This avoids compromise of the inguinal canal, and with medial retraction of the rectus abdominis muscle enables access to the peritoneal cavity and compromised bowel. Discussion This simple technique minimises the preoperative debate as to which incision will allow the best approach to the femoral hernia sac, allow for alteration to a simple inguinal hernia repair if necessary, and more importantly obviate the need for further skin incisions if compromised bowel is encountered that requires resection.

  2. [Angioscopy and angioplasty of the iliac and femoral arteries].

    Science.gov (United States)

    Baudrillard, J C; Cécile, J P; Foucart, H; Carlier, C; Baidj, Z

    1990-01-01

    Angioscopy is a technique of endoscopic investigation of the vascular lumen and its contents, which we have coupled with iliac and femoral angioplasty. The material comprises 3 main elements: the angioscope, the TV-monitoring assembly and the infusion system. No complication was recorded in a series of 94 angioscopies (47 iliac, 44 distal femoral and 3 grafts) performed over a period of 18 months. The technical quality of the images obtained was good in 90% of cases (85/94). Angioscopy revealed lesions that had either been nonvisualized or underrated by angiography, and played a determinant role in 16% of cases (15/94), whereby the therapeutical procedure could be modified accordingly.

  3. Desenvolvimento de um novo conceito de implante patelo-femoral

    OpenAIRE

    Vieira, Eugénio Vítor Caldeira

    2012-01-01

    O joelho é uma das articulações mais importantes do corpo humano, permite a mobilidade e a estabilidade em simultâneo. Algumas patologias como a síndrome patelo-femoral podem conduzir à necessidade da realização da artroplastia patelo-femoral. Vários efeitos comprometem a longevidade desta artroplastia, sendo os mais frequentes o efeito de stress shielding, responsável pela reabsorção óssea localizada, o efeito de fadiga por sobrecarga associado à geração de microfissuras e ...

  4. Risk of pelvic injury from femoral neck guidewires.

    Science.gov (United States)

    Feeney, M; Masterson, E; Keogh, P; Quinlan, W

    1997-01-01

    Many of the devices used in the internal fixation of femoral neck fractures are cannulated and require the initial placement of one or more guidewires for accurate positioning. These wires are occasionally advanced inadvertently through the hip joint and the acetabulum. Pelvic visceral damage may follow. To assess this risk, we inserted three guidewires to a depth of 16 cm into each femoral neck of ten cadavers and explored the pelvis during autopsy. Thirty-two of the 60 guidewires had penetrated a pelvic organ. The literature on intrapelvic injuries associated with hip surgery is reviewed, and suggestions are offered on the avoidance of pelvic penetration during hip fracture fixation.

  5. [Femoral head chondroblastoma and reconstruction with osteochondral allograft. Case report].

    Science.gov (United States)

    Orlando-Díaz, C; Guzmán-Vargas, R; Rincon-Cardozo, D F; Mantilla-León, N; Camacho-Casas, J A

    2014-01-01

    Femoral head chondroblastoma is an infrequent tumor, accounting for approximately 1-2% of benign bone tumors. It occurs more frequently in young male patients. It's most frequent locations include the proximal humerus, proximal femur, distal femur and proximal tibia. The femoral head is the third most frequent site of this tumor. There is no specific treatment for this entity; reported treatments range from acetabular osteotomies and osteochondral grafts, to vascularized fibular grafts, all of them with good results. However, this tumor is clinically unpredictable if left untreated. We report a case managed with osteochondral graft and followed-up for three years after the surgical procedure.

  6. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  7. Medial circumflex femoral artery flap for ischial pressure sore

    Science.gov (United States)

    Palanivelu, S.

    2009-01-01

    A new axial pattern flap based on the terminal branches of the medial circumflex femoral artery is described for coverage of ischial pressure sore. Based on the terminal branches of the transverse branch of medial circumflex femoral artery, which exit through the gap between the quadratus femoris muscle above and the upper border of adductor magnus muscle below, this fascio cutaneous flap is much smaller than the posterior thigh flap but extremely useful to cover ischeal pressure sores. The skin redundancy below the gluteal fold allows a primary closure of the donor defect. It can also be used in combination with biceps femoris muscle flap. PMID:19881020

  8. Automatic quantification of tibio-femoral contact area and congruity

    DEFF Research Database (Denmark)

    Tummala, Sudhakar; Nielsen, Mads; Lillholm, Martin;

    2012-01-01

    We present methods to quantify the medial tibio- femoral (MTF) joint contact area (CA) and congruity index (CI) from low-field magnetic resonance imaging (MRI). Firstly, based on the segmented MTF cartilage compartments, we computed the contact area using the Euclidian distance transformation....... The CA was defined as the area of the tibial superior surface and the femoral inferior surface that are less than a voxel width apart. Furthermore, the CI is computed point-by-point by assessing the first- and second-order general surface features over the contact area. Mathematically, it is the inverse...

  9. Loosening Up the Uptight Student.

    Science.gov (United States)

    Landsman, Julie

    1993-01-01

    Focuses on releasing students' creative impulses, their imaginations, and their memories. Discusses a set of reading and writing activities that have been used with all kinds of students in a wide variety of settings. (RS)

  10. Loosening up the Skyrme model

    CERN Document Server

    Gudnason, Sven Bjarke

    2016-01-01

    We consider the Skyrme model with the addition of extra scalar potentials that decrease the classical binding energies of the Skyrmions to about the 3% level -- without altering the pion mass -- if we insist on keeping platonic symmetries that are usually possessed by Skyrmions. A side effect of the potentials under consideration is the smaller size of the 1-Skyrmion resulting in a smaller moment of inertia and in turn a larger spin contribution to the energy upon semi-classical quantization. After taking into account the quantum contributions we find total binding energies at the 6% level.

  11. Amputated limb by cerclage wire of femoral diaphyseal fracture: a case report.

    Science.gov (United States)

    Won, Yougun; Yang, Kyu-Hyun; Kim, Kwang-Kyoun; Weaver, M J; Allen, Elizabeth M

    2016-12-01

    An entrapment of the femoral artery by cerclage wiring is a rare complication after spiral diaphyseal femoral fractures. We report the case of an 82-year-old female treated by an antegrade intramedullary nailing and multiple cable augmentation, which was then complicated by injury to the femoral artery that resulted in ipsilateral leg necrosis and amputation. The entrapment was caused by direct belting by the cable and resulted in a total obstruction of the femoral artery.

  12. Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study.

    Science.gov (United States)

    Konya, Mehmet Nuri; Verim, Özgür

    2017-09-29

    Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. Biomechanical study. Computed tomography images of patients' right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis.

  13. Two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique that avoids the use of a femoral bridging dialysis catheter.

    Science.gov (United States)

    Yoon, William J; Lorelli, David R

    2015-01-01

    The purpose of this study is to report a novel two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique that avoids the use of a femoral bridging hemodialysis catheter in internal jugular vein (IJV) catheter-dependent patients with contralateral central venous occlusion. The first stage is to implant the ePTFE component and consists of: 1) performing two to three incisions in the upper arm ipsilateral to the preexisting IJV catheter, 2) tunneling the expanded polytetrafluoroethylene (ePTFE) component through these incision sites, and 3) placing the ePTFE component in the subcutaneous tissue without anastomosing it to the target artery. The preexisting IJV catheter is maintained to provide continuous dialysis access. The second stage is initiated in 4 weeks and includes: 1) thrombectomy and anastomosing the ePTFE component arterial end to the target artery, 2) insertion of the venous outflow component using the preexisting IJV catheter access site, and 3) connecting the venous outflow component to the ePTFE component in the standard fashion. The HeRO graft was successfully implanted in two stages without using a femoral bridging catheter. Immediate postimplant cannulatabilty was achieved upon completion of the second stage procedure. This novel two-stage HeRO implantation technique is simple, yet allows immediate cannulation upon completion of the second stage procedure while avoiding the need of a femoral bridging catheter in IJV catheter- dependent patients with contralateral central venous occlusion, and thus lowering the risk of infection related to a femoral bridging catheter.

  14. 肿瘤型假体无菌性松动的治疗现状%Current status of the treatment of aseptic loosening in tumor prostheses

    Institute of Scientific and Technical Information of China (English)

    高明; 张清; 牛晓辉

    2014-01-01

    Aseptic loosening ( AL ) is one of the most common complications in tumor prostheses. Loss of bone quantity and decline of bone quality are the main challenges that orthopedists encounter when they deal with AL. Based on the latest reports, prosthesis revision is the primary choice in the treatment of AL, and it can provide relatively satisfactory outcomes when compared with other methods. While it needs enough bone quantity and good bone quality for prosthetic stability. In some reports, it can get a median Musculoskeletal Tumor Society ( MSTS ) functional score of 96% ( range: 50%-100% ) after an average follow-up of 101 months ( range: 47-155 months ) after the surgery. Besides this, allograft-prosthesis composites ( APCs ) are another choice. Allograft segments are used to construct a certain ifxation arm to get a more stable ifxation. However, its outcomes are not as satisfactory as that of prosthesis revision. According to some reports, after an average follow-up of 59 months after the surgery, it can provide an average MSTS functional score of 62% ( range: 57%-67% ). While we must take account that these patients receiving APCs always have less bone quantity and worse bone quality, when compared with those only receiving prosthetic treatment. In recent years, a new type of prosthesis based on extra-cortical plate ifxation has been used in the revision, which is superior to the conventional intramedullary stem prosthesis. The current results illustrate that it has certain application prospects, but high-quality studies are needed to further demonstrate it. When the loss of bone quantity and decline of bone quality are too serious to perform limb salvage treatment, rotationplasty and amputation may be a choice. However, great attention must be paid to their indications.

  15. Significance of nitric oxide on the pathogenesis of steroid-induced femoral head necrosis

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@Steroid-induced femoral head necrosis is claimed to be an ischemic femoral head disease. But there is no discussion on the role of nitric oxide (NO) in the idiopathic disease. The concentration of NO indirectly in serum with steroid induced avascular necrosis of femoral head (ANFH) and in controls are studied in this article.

  16. Common femoral vein reconstruction using internal jugular vein after blast injury.

    Science.gov (United States)

    Holt, Andrew M; West, Charles A; Davis, James A; Gilani, Ramyar; Askenasy, Eric

    2014-10-01

    Common femoral vein traumatic injuries are rare. Surgical management is controversial and by nature case specific. In this report, we present an unusual case of an isolated common femoral vein injury from a gunshot blast repaired with an interposition internal jugular vein bypass. To our knowledge, this is the first reported case of an isolated common femoral vein reconstructed in this manner.

  17. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral...

  18. APPLICATION ON THE COOPERATION BETWEEN WARP LOOSENING DEVICE AND THE BACK REST FOR AIR JET LOOMS%喷气织机松经机构与后梁配合的应用探讨

    Institute of Scientific and Technical Information of China (English)

    刘忧华

    2015-01-01

    The structure and function of air-jet looms warp loosening device was introduced , and analyzed the function of co-ordination between Warp loosening device and the back rest for Air Jet loom. It can be stable equilibrium in the process of weaving warp tension to reduce the tension fluctuation for wealing.%介绍了喷气织机松经装置的结构及作用,分析了后梁和松经装置的配合使用,可在织造过程中稳定均衡经纱张力,减少张力的波动,以利于织造的进行。

  19. Long-term results of femoral revision with the Wagner Self-Locking stem.

    Science.gov (United States)

    Regis, Dario; Sandri, Andrea; Bonetti, Ingrid

    2013-09-01

    Femoral revision total hip arthroplasty may be a complex procedure due to extensive periprosthetic bone loss. Fluted, tapered stems provide secure axial and rotational stability in the distal femur. We retrospectively evaluated the long-term outcome of the cementless Wagner Self-Locking prosthesis (Sulzer Orthopedics Ltd, Winterthur, Switzerland). From 1992 to 1998, 68 consecutive femoral revisions were performed in 66 patients using the Wagner tapered stem. Twenty-five patients deceased for unrelated causes without additional surgery. The studied group consisted of 41 hips in 41 patients, 12 males and 29 females, aged from 29 to 80 years (mean 61 years). Thirty-five hips (85.4%) included severe deficiency of bone stock. A transfemoral approach was carried out in 32 cases (78%). Bone grafting was never supplemented. Average follow-up was 13.9 years (range 10.4 to 15.8 years). Clinical evaluation was performed using Harris Hip Score (HHS). Osseointegration of the stem and progression of periprosthetic bone remodelling were assessed radiographically. Five stems required rerevision because of deep infection (2), progressive subsidence (2) complicated by hip instability and head-neck disassembly, and old dislocation following acetabular component failure (1). Four hips (9.7%) dislocated, and 8 stems (19.5%) subsided significantly. Average HHS improved from 33 points preoperatively to 75 points at the latest follow-up examination (p risk complications (dislocation, subsidence) should be minimized by the development of modular stems.

  20. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    吴立东; 金礼斌; 严世贵; 杨泉森; 戴雪松; 王祥华

    2004-01-01

    Objective:To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.Methods: Between 1995 and 2002, we implanted 23cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with acementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabuinm and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31%(ranging from 10% to 45%). Eight hips had less than 25%cup coverage and thirteen between 25% and 50%. The average follow-up period was 4.7 years (range, 1-8 years).The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made.Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia.After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1Brooker heterotopic ossification and one developed Grade 2.Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in

  1. [Spontaneous disappearance of herniation pit on the femoral neck].

    Science.gov (United States)

    Lerais, J M; Jacob, D; Thibaud, J C; Fourrer, C; Cercueil, J P; Krause, D; Laredo, J D; Baudrillard, J C

    1995-09-01

    The authors present a case of a 39 years old patient who had a herniation pit of the left femoral neck, 5 years ago. This lesion disappeared spontaneously. To our knowledge, no report of healing of a herniation pit has been previously described.

  2. MR imaging findings of the femoral marrow in myelodysplastic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Osamu; Takagi, Shojiro; Matsuura, Katsuhiko; Ichikawa, Tamaki; Kobayashi, Yasuyuki; Nagai, Jun [Jichi Medical School, Minamikawachi, Tochigi (Japan)

    1995-10-01

    MR imaging of the femoral marrow was performed in 30 patients with myelodysplastic syndrome (MDS), 11 cases of which evolved to acute myeloid leukemia (AML). The MRI appearance was classified into five patterns: fatty marrow; faint signal; nodular pattern; heterogeneous infiltration; and diffuse infiltration. For each type of MDS, MRI patterns of the femoral marrow were evaluated and compared with those in normal subjects as well as in patients with aplastic anemia. Signal intensity alteration, a low signal on T1-weighted SE image and a high signal on STIR image, began in the proximal femoral marrow almost symmetrically in patients with MDS. The area of abnormal signal intensity tended to gradually extend towards the distal portion of the femur as the disease progressed. MRI patterns of the femoral marrow correlated with marrow cellularity, and diffuse marrow infiltration was noted in patients with a more advanced type of MDS or with severe anemia. There were limitations to making an accurate diagnosis of the MDS type on the basis of the MRI pattern. Progression of the MRI appearance in the course of MDS was thought to be a sign suggesting evolution to AML. It was difficult to differentiate hypoplastic MDS from aplastic anemia, although the nodular pattern was commonly seen in the latter disease. (author).

  3. Internal Fixation of Femoral Neck Fractures : Treatment and effects

    NARCIS (Netherlands)

    S.M. Zielinski (Stephanie)

    2015-01-01

    markdownabstract__Abstract__ This thesis consists of three parts. Part 1 described aspects of the organization of trauma related trials. Part 2 analyzed the uniformity of current femoral neck fracture treatment and adherence to the Dutch guideline on hip fracture treatment. The implications of

  4. Pattern of femoral fractures and associated injuries in a Nigerian ...

    African Journals Online (AJOL)

    2014-10-09

    Oct 9, 2014 ... Key words: Associated injuries, femoral fractures, Nigeria, pattern ... Nnewi Campus, Anambra State, 2Plastic Surgery Unit, St. Francis Hospital, Asata, Enugu, Nigeria. Address for .... Follow‑up for patients include physical therapy, early mobilization, counseling and medical therapy, out‑patient visits until ...

  5. Proximal focal femoral deficiency: evaluation by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [National Naval Medical Center, Department of Radiology, Bethesda, MD (United States); Uniformed Services University of Health Sciences, Department of Radiology and Radiological Sciences, Bethesda, MD (United States); Davidson, Richard [The Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Pena, Andres; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2012-01-15

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  6. Low-energy trauma-induced intercondylar femoral fracture

    Science.gov (United States)

    Aeby, Mathias; Wyss, Tobias; Mentrup, Birgit; Kunstmann, Erdmute; Jakob, Franz; Aeberli, Daniel

    2016-01-01

    Summary We present a 44-year-old female patient with recurrent fragility fractures including an intercondylar femoral fracture and with normal planar bone densitometry. Diagnosis of hypophosphatasia was suggested by low volumetric cortical bone mineral density and laboratory findings. DNA sequencing revealed heterozygous mutations in the exons 5, 6 and 9 of the ALPL gene, thus confirming the suspected diagnosis. PMID:27920814

  7. Adductor Canal Block versus Femoral Nerve Block and Quadriceps Strength

    DEFF Research Database (Denmark)

    Jæger, Pia Therese; Nielsen, Zbigniew Jerzy Koscielniak; Henningsen, Lene Marianne;

    2013-01-01

    : The authors hypothesized that the adductor canal block (ACB), a predominant sensory blockade, reduces quadriceps strength compared with placebo (primary endpoint, area under the curve, 0.5-6 h), but less than the femoral nerve block (FNB; secondary endpoint). Other secondary endpoints were...

  8. Outcomes after External Iliac and Femoral Vascular Injuries.

    Science.gov (United States)

    Kim, Jerry J; Alipour, Hamid; Yule, Arthur; Plurad, David S; Koopmann, Matthew; Putnam, Brant; de Virgilio, Christian; Kim, Dennis Y

    2016-05-01

    Vascular injuries occurring at the junction of the trunk and lower extremity are uncommon yet challenging because of their location and potential for associated truncal injuries. The purpose of this study was to examine and compare outcomes among patients sustaining external iliac and femoral vascular injuries. We performed a 13-year retrospective analysis of our level 1 trauma center database to identify and compare patients with external iliac and femoral vessel injuries. Multiple logistic regression analysis was performed to identify independent predictors for mortality. During the study period, 135 patients with a median (interquartile range [IQR]) age of 25 (20-35) years were identified with external iliac (n = 29) and femoral vascular injuries (n = 106). The majority were male (85.9%) with a penetrating mechanism (84.5%), and the median (IQR) Injury Severity Score (ISS) was 16 (11-26). The overall mortality rate was 14.1%. In comparison with patients with femoral vascular injuries, patients with external iliac injuries presented with higher ISS (25 vs. 16, P vascular injuries, external iliac vascular injuries are associated with higher blood loss, more intense resuscitation, higher disability and mortality in patients sustaining junctional groin injuries. Early recognition and application of damage control techniques and resuscitative practices may result in improved outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Femoral nailing in adults : doctor and patient reported outcomes

    NARCIS (Netherlands)

    El Moumni, Mostafa

    2016-01-01

    The treatment of traumatic femoral shaft fractures using an unreamed nail is associated with good results. Both antegrade and retrograde unreamed nailing techniques result in high union rates and low rates of complications, such as non-union, deep infection and septic arthritis. These results are co

  10. Simultaneous post traumatic bilateral cervico-trochanteric femoral ...

    African Journals Online (AJOL)

    Femoral neck fractures in children are usually caused by ... reinforcement and to prevent rotation at the fracture site (Fig. .... arsenic, it is unlikely that this was the cause ofhis disease. ... used to poison some tree species but he denied using it.

  11. Retained portion of latex glove during femoral nailing. Case report.

    Science.gov (United States)

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  12. Periprosthetic subtrochanteric femoral fracture in a megaprosthesis of the knee

    Institute of Scientific and Technical Information of China (English)

    Raju Vaishya; Ajay Pal Singh; Abhishek Vaish

    2013-01-01

    We report a rare case of periprosthetic posttraumatic fracture of subtrochanteric region of femur after a megaprosthesis of the knee,done for resistant nonunion of distal femur with secondary osteoarthrosis in a 51 years old man.Treatment with a locking femoral plate was able to achieve primary union with a good result.

  13. Chondroblastoma of the femoral head: management and outcome.

    Science.gov (United States)

    Strong, D P; Grimer, R J; Carter, S R; Tillman, R M; Abudu, A

    2010-03-01

    Chondroblastoma of the femoral head presents particular problems in treatment because the tumour is surrounded by articular cartilage on one side and epiphyseal plate on the other. Ten patients underwent treatment for a chondroblastoma involving the proximal femoral capital epiphysis. The patients were aged between eight and 19 years and in four the epiphysis was not yet fused. Five had curettage via a drill hole created up the femoral neck, of whom two developed local recurrence. Five had a direct approach to the chondroblastoma through the femoral neck, and there were no local recurrences in this group. Both patients with local recurrence were under 14 years of age-one was cured by a direct approach through the neck of the femur and the other by lifting a trap door of articular cartilage. Apart from one patient with a temporary leg length discrepancy, there were no other complications. We conclude that a direct approach is likely to lead to the best outcome for this rare condition.

  14. Femoral head-neck junction reconstruction, after iatrogenic bone resection.

    Science.gov (United States)

    Guevara-Alvarez, Alberto; Lash, Nicholas; Beck, Martin

    2015-07-01

    Arthroscopic over-resection of the head-neck junction during the treatment of a cam deformity can be a devastating complication and is difficult to treat. Large defects of the femoral head-neck junction (FHNJ) increase the risk of femoral neck fracture and can also affect hip biomechanics. We describe a case of an iatrogenic defect of the FHNJ due to excessive bone resection, and a previously non-described treatment using iliac crest autograft to restore femoral head-neck sphericity and hip joint stability. After protecting the femoral neck with an angled blade plate, the large anterior FHNJ defect was reconstructed using autogenous iliac crest bone graft; sphericity was restored by contouring the graft using spherical templates. Clinical and radiographic follow-up was performed up to 2 years. Results at 2 years showed no residual groin pain and normal range of motion. The Oxford Hip Score was 46/48, rated as excellent. Computed tomography (CT) scanning showed union of bone graft without resorption, and CT arthrogram indicating retained sphericity of the FHNJ without evidence of degenerative changes in the articular surface. This novel surgical technique can be used to restore the structural integrity and contour of the FHNJ that contains a significant anterior defect.

  15. The Femoral Hernia-a rare hernia and its treatment

    Institute of Scientific and Technical Information of China (English)

    Andreas Hoeferlin

    2009-01-01

    @@ Introduction Hernias age protrusions through weak areas of our abdominal wall.The most common hernia is Inguinal Hernia in men.A rather rare hernia is the Femoral Hernia,a protrusion into the femotal canal next to the blood vessels in our groin (Picl).

  16. Arthroscopic Treatment of Medial Femoral Condylar Coronal Fractures and Nonunions

    Science.gov (United States)

    Ercin, Ersin; Bilgili, M. Gokhan; Basaran, S. Hakan; Baca, Emre; Kural, Cemal; Avkan, M. Cevdet

    2013-01-01

    Nonunion of medial femoral condylar coronal fractures are uncommon. In neglected Hoffa fractures despite nonunion, there is a risk of missing accompanying ligamentous and intra-articular injuries. Neither preoperative clinical examination nor magnetic resonance imaging showed these injuries before arthroscopy. Arthroscopy before internal fixation gives additional information and changes the surgical protocol for these fractures and nonunions. PMID:24400191

  17. Residual hip growth after pinning of slipped capital femoral epiphysis.

    Science.gov (United States)

    Breaud, Jean; Rubio, Amandine; Leroux, Julien; Griffet, Jacques

    2009-01-01

    Screwing of slipped capital femoral epiphysis must prevent its further slipping by prematurely fusing the physis. Whichever material is used, persistent femoral growth has been described, thereby increasing the risk of bone deformation. The objective of this study is to evaluate the residual growth after screwing of slipped capital femoral epiphysis. This study concerned 26 children, among which 13 children have been included, and 13 children excluded because of an incomplete clinical or radiological follow-up, or treatment by another technique. The pathological hip was treated with one screw (in eight cases) or two screws (in five cases). The controlateral hip was fixed with one screw. The different measures were taken on anteroposterior radiographs done the days after surgery, and on the first radiograph on which the growth plate had fused. Growth plate fusion was obtained after an average of 20 months. Each patient had presented a residual growth of at least one hip, thus 85% of the 26 fixed screws. Among the four hips, which did not grow, three were pathological, and were fixed by one screw (in one case) or two screws (in two cases), in a central or medial position. There was not any statistical relationship between the growth persistence and the other studied criteria. These results, proving the growth persistency, suggest that the follow-up must be extremely careful, as the number of threads crossing the growth plate will decrease, with the risk of loss of mechanical stability and reappearance of the femoral epiphysis slippage.

  18. Quadratus lumborum block for femoral–femoral bypass graft placement

    Science.gov (United States)

    Watanabe, Kunitaro; Mitsuda, Shingo; Tokumine, Joho; Lefor, Alan Kawarai; Moriyama, Kumi; Yorozu, Tomoko

    2016-01-01

    Abstract Introduction: Atherosclerosis has a complex etiology that leads to arterial obstruction and often results in inadequate perfusion of the distal limbs. Patients with atherosclerosis can have severe complications of this condition, with widespread systemic manifestations, and the operations undertaken are often challenging for anesthesiologists. Case report: A 79-year-old woman with chronic heart failure and respiratory dysfunction presented with bilateral gangrene of the distal lower extremities with obstruction of the left common iliac artery due to atherosclerosis. Femoral–femoral bypass graft and bilateral foot amputations were planned. Spinal anesthesia failed due to severe scoliosis and deformed vertebrae. General anesthesia was induced after performing multiple nerve blocks including quadratus lumborum, sciatic nerve, femoral nerve, lateral femoral cutaneous nerve, and obturator nerve blocks. However, general anesthesia was abandoned because of deterioration in systemic perfusion. The surgery was completed; the patient remained comfortable and awake without the need for further analgesics. Conclusion: Quadratus lumborum block may be a useful anesthetic technique to perform femoral–femoral bypass. PMID:27583851

  19. Scaling in Theropod Dinosaurs: Femoral Bone Strength and Locomotion II

    Science.gov (United States)

    Lee, Scott

    2015-01-01

    In the second paper of this series, the effect of transverse femoral stresses due to locomotion in theropod dinosaurs of different sizes was examined for the case of an unchanging leg geometry. Students are invariably thrilled to learn about theropod dinosaurs, and this activity applies the concepts of torque and stress to the issue of theropod…

  20. Postmortem Femoral Blood Reference Concentrations of Aripiprazole, Chlorprothixene, and Quetiapine

    DEFF Research Database (Denmark)

    Skov, Louise; Johansen, Sys Stybe; Linnet, Kristian

    2015-01-01

    Postmortem femoral blood concentrations of the antipsychotic drugs aripiprazole, chlorprothixene and its metabolite, and quetiapine were determined by LC-MS-MS in 25 cases for aripiprazole and 60 cases each for chlorprothixene and quetiapine. For cases where the cause of death was not related to ...

  1. Cementless bipolar hemiarthroplasty in femoral neck fractures in elderly

    Directory of Open Access Journals (Sweden)

    SKS Marya

    2011-01-01

    Conclusion: Cementless bipolar hemiarthroplasty for femoral neck fractures in the very elderly permits early return to premorbid life and is not associated with any untoward cardiac event in the perioperative period. It can be considered a treatment option in this select group.

  2. Femoral fractures : indications an[d] biomechanics of external fixation

    NARCIS (Netherlands)

    A.H. Broekhuizen (Tom); B. van Linge

    1988-01-01

    textabstractInternal fixation can be carried out in various ways. For femoral shaft fractures, an (interlocking) nail is becoming increasingly popular, instead of open realignment of the fracture. External fixation, which has become a generally accepted method of treating fractures of the lower

  3. Unusual Foreign Bone Fragment in Femoral Open Fracture

    Science.gov (United States)

    Sadoni, Hanon; Arti, Hamidreza

    2016-01-01

    Introduction: Femoral shaft fracture is one of the typical bone fractures due to high energy trauma and may occur as an open fracture. Some foreign materials may enter the fracture site such as sand, cloth particles and so on. Case Presentation: A 28-year-old motorcycle riding military member and his collaborator were received in the hospital because of multiple traumas due to a fall in a hollow during a surveillance mission. His collaborator died because of head trauma and multiple severe open fractures. When fixing the patients femoral fracture, a large femoral butterfly fragment was removed from the patient’s thigh as a foreign segment. The patient’s femur was fixed with a plate and screws. No femoral defect was detected during surgery or post-operative X-rays and CT scan. The removed segment was not a part of the patient’s femur. Conclusions: Surgical and post-surgical findings showed that this segment was not related to the patient’s femur. The foreign segment may have belonged to the other victim of this trauma. PMID:27218050

  4. Progressive slippage after pinning for slipped capital femoral epiphysis.

    Science.gov (United States)

    Sanders, James O; Smith, William J; Stanley, Earl A; Bueche, Matthew J; Karol, Lori A; Chambers, Henry G

    2002-01-01

    The authors retrospectively reviewed seven cases of progressive slipped capital femoral epiphysis after screw fixation. All seven patients initially presented with chronic symptoms, and five had an acute exacerbation of symptoms with the appearance of an acute-on-chronic slip. Of the other two, one had obvious motion at the proximal femoral physis and the other had increased symptoms but did not have an obvious acute slip radiographically. All underwent percutaneous screw fixation. In four patients a single screw was placed, and in three patients two screws were placed. No patient became symptom-free after surgery. Slip progression was noted on average 5 months after treatment. Radiographs in all patients revealed an increase in slip severity and loss of screw purchase in the femoral neck while fixation in the proximal femoral epiphysis remained secure. One patient had hypothyroidism and another Cushing disease, both diagnosed after the slipped epiphysis. Slips occurring in children with underlying endocrinopathies, and unstable slips in children with a history of antecedent knee or hip pain (commonly called an acute-on-chronic slip) may be susceptible to screw fixation failure. In such patients, close radiographic follow-up, particularly in the presence of continued symptoms, is required to document slip progression and fixation failure as soon as possible.

  5. A De Garengeot Hernia masquerading as a strangulated femoral hernia

    Directory of Open Access Journals (Sweden)

    A. Hussain

    2014-01-01

    CONCLUSION: A De Garengeot's hernia should be considered as a differential diagnosis in patients presenting with clinical signs of a strangulated femoral hernia. It is often an incidental finding during an emergency operation. Although mesh repairs in the presence of appendicitis have been reported, the safest approach remains a primary suture repair.

  6. Inflamed appendix in a femoral hernial sac: de Garengeot's hernia.

    Science.gov (United States)

    Rajan, S S; Girn, H R S; Ainslie, W G

    2009-10-01

    Croissant de Garengeot's hernia is defined as the presence of an appendix in the femoral hernial sac. It is rare and occurs mostly in females. We report this hernia in a male patient along with the surgical management and review of literature.

  7. Mechanical properties of femoral trabecular bone in dogs

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2005-03-01

    Full Text Available Abstract Background Studying mechanical properties of canine trabecular bone is important for a better understanding of fracture mechanics or bone disorders and is also needed for numerical simulation of canine femora. No detailed data about elastic moduli and degrees of anisotropy of canine femoral trabecular bone has been published so far, hence the purpose of this study was to measure the elastic modulus of trabecular bone in canine femoral heads by ultrasound testing and to assess whether assuming isotropy of the cancellous bone in femoral heads in dogs is a valid simplification. Methods From 8 euthanized dogs, both femora were obtained and cubic specimens were cut from the centre of the femoral head which were oriented along the main pressure and tension trajectories. The specimens were tested using a 100 MHz ultrasound transducer in all three orthogonal directions. The directional elastic moduli of trabecular bone tissue and degrees of anisotropy were calculated. Results The elastic modulus along principal bone trajectories was found to be 11.2 GPa ± 0.4, 10.5 ± 2.1 GPa and 10.5 ± 1.8 GPa, respectively. The mean density of the specimens was 1.40 ± 0.09 g/cm3. The degrees of anisotropy revealed a significant inverse relationship with specimen densities. No significant differences were found between the elastic moduli in x, y and z directions, suggesting an effective isotropy of trabecular bone tissue in canine femoral heads. Discussion This study presents detailed data about elastic moduli of trabecular bone tissue obtained from canine femoral heads. Limitations of the study are the relatively small number of animals investigated and the measurement of whole specimen densities instead of trabecular bone densities which might lead to an underestimation of Young's moduli. Publications on elastic moduli of trabecular bone tissue present results that are similar to our data. Conclusion This study provides data about directional elastic

  8. Comparative characteristics of osteosynthesis techniques in patients with comminuted diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2013-01-01

    Full Text Available The comparative analysis of the results of the surgical treatment of 130 patients with closed comminuted unilateral diaphyseal femoral fractures, including assessment of anatomic functional outcomes of treatment according to the technique of the standardized investigations in traumatology and orthopedy and determination of quality of life according to SF-36 method is carried out. Osteosynthesis with the help of external fixation devices was performed in 36 patients, intramedullary interlocking osteosynthesis - in 57 patients, compression plating - in 37 patients. Level of anatomic functional rehabilitation of the patients in the early postoperative period made up 69-79 %, 6 months later increased up to 74-92%, and after the expiration of 12 months the level of rehabilitation reached 85-99%. During the treatment quality of life concerning physical component was within the limits from 36,8 up to 55,5 %, and concerning mental component - 54,3-60,8 %. After the expiration of a year increase in the parameters of physical and mental components up to 55,7 - 59,8 % and 57,2-65,8 % is detected respectively. In the group where the transosseous osteosynthesis technique was applied we got 93,7-95 % of positive outcomes, with the average disability period of 212,3±18,1 days. In 47,2 % of cases the following complications are observed: knee contracture - 7; inflammation of the soft tissues located near the transosseous fixators - 5 (13,9%; shortening of the limb less than 5% of its length - 3; false joint formation - 1; fracture union with formation of varus deformity in the femoral bone - 1. When using intramedullary interlocking osteosynthesis we had positive results in 96,5 % of cases, with the average period of disability 176±17,8 days. In 10,5 % cases the following complications are observed: suture sinus - 1(1,75 %; femoral osteomyelitis - 1; break of the design - 1; false joint formation - 1; knee contracture - 1; shortening of the limb less than 5

  9. Study of the anatomical position of the femoral nerve by magnetic resonance imaging in patients with fractured neck of femur: relevance to femoral nerve block.

    LENUS (Irish Health Repository)

    Mehmood, Shehzad

    2012-01-31

    STUDY OBJECTIVE: To determine the anatomical location of the femoral nerve in patients who have sustained fracture of the neck of femur, and its relevance to femoral nerve block technique. DESIGN: Prospective, observational clinical study. SETTING: Orthopedic and Radiology departments of a regional hospital. SUBJECTS: 10 consecutive adult ASA physical status II and III patients (mean age, 78.5 yrs) and 4 adult healthy volunteers. INTERVENTIONS: A T1 magnetic resonance imaging scan was performed of both upper thighs in patients and healthy volunteers successfully. MEASUREMENTS: The distance (mm) between the midpoint of the femoral artery and the midpoint of the femoral nerve, and the distance of the femoral nerve from the skin was measured at the mid-inguinal ligament, the pubic tubercle, and at the mid-inguinal crease. Data are shown as means (SD). Differences between both sides were compared using paired Student\\'s t-tests. P < 0.05 was significant. MAIN RESULTS: In patients the mean distance (mm) between the midpoint of the femoral nerve from the midpoint of femoral artery at the mid-inguinal crease on the fractured and non-fractured sides was 10.7 and 11.0, respectively (P = 0.87). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the mid-inguinal ligament on the fractured and non-fractured sides was 9.64 and 12.5, respectively (P = 0.03). The mean distance (mm) between the midpoint of the femoral nerve from the midpoint of the femoral artery at the pubic tubercle on the fractured and non-fractured sides was 8.74 and 10.49, respectively (P = 0.18). CONCLUSIONS: Blockade of the femoral nerve may be easier to perform at the mid-inguinal crease in patients with fractured neck of femur.

  10. Current concepts on osteonecrosis of the femoral head.

    Science.gov (United States)

    Moya-Angeler, Joaquin; Gianakos, Arianna L; Villa, Jordan C; Ni, Amelia; Lane, Joseph M

    2015-09-18

    It is estimated that 20000 to 30000 new patients are diagnosed with osteonecrosis annually accounting for approximately 10% of the 250000 total hip arthroplasties done annually in the United States. The lack of level 1 evidence in the literature makes it difficult to identify optimal treatment protocols to manage patients with pre-collapse avascular necrosis of the femoral head, and early intervention prior to collapse is critical to successful outcomes in joint preserving procedures. There have been a variety of traumatic and atraumatic factors that have been identified as risk factors for osteonecrosis, but the etiology and pathogenesis still remains unclear. Current osteonecrosis diagnosis is dependent upon plain anteroposterior and frog-leg lateral radiographs of the hip, followed by magnetic resonance imaging (MRI). Generally, the first radiographic changes seen by radiograph will be cystic and sclerotic changes in the femoral head. Although the diagnosis may be made by radiograph, plain radiographs are generally insufficient for early diagnosis, therefore MRI is considered the most accurate benchmark. Treatment options include pharmacologic agents such as bisphosphonates and statins, biophysical treatments, as well as joint-preserving and joint-replacing surgeries. the surgical treatment of osteonecrosis of the femoral head can be divided into two major branches: femoral head sparing procedures (FHSP) and femoral head replacement procedures (FHRP). In general, FHSP are indicated at pre-collapse stages with minimal symptoms whereas FHRP are preferred at post-collapse symptomatic stages. It is difficult to know whether any treatment modality changes the natural history of core decompression since the true natural history of core decompression has not been delineated.

  11. Pentosan reduces osteonecrosis of femoral head in SHRSP.

    Science.gov (United States)

    Miyata, Noriaki; Kumagai, Kenji; Osaki, Makoto; Murata, Masakazu; Tomita, Masato; Hozumi, Akira; Nozaki, Yoshihiro; Niwa, Masami

    2010-01-01

    Increased oxidative stress is considered one of the main causes of steroid-induced osteonecrosis of the femoral head (ONFH). The aim of this study was to evaluate the effects of a steroid hormone and pentosan polysulfate sodium (pentosan), a heparin analog, in stroke-prone spontaneously hypertensive rats (SHRSP) as a model of ONFH. One hundred twenty-three 13-week-old male SHRSP/Izm rats were divided into four groups: a control group (group C), pentosan-administered group (group P), steroid-administered group (group S), and group administered pentosan plus steroid (group PS). Methylprednisolone acetate, as the steroid hormone, at a dose of 4 mg (15 mg/kg) was administered at 15 weeks of age. Pentosan at a dose of 3 mg/day/kg was continuously administered intraperitoneally from 13 weeks of age for 4 weeks. Rats were sacrificed at 17 weeks of age, and heart blood and both femora were collected. Triglyceride levels were significantly lower in group PS than in group S, indicating that pentosan improves lipid metabolism. The incidence of histologic ONFH was significantly lower in group P, at 14.8% (10/71 femoral heads), than in group C, at 30.4% (17/56 femoral heads), and significantly lower in group PS, at 40.8% (29/71 femoral heads), than in group S, at 91.3% (42/46 femoral heads), indicating that pentosan markedly inhibits ONFH. Immunohistochemical staining for oxidative stress showed that the stainability was significantly lower in group PS than in group S. Pentosan seems to reduce the incidence of ONFH in SHRSP by improving lipid metabolism and decreasing oxidative stress.

  12. Groove model of tibia-femoral osteoarthritis in the rat.

    Science.gov (United States)

    de Visser, Huub M; Weinans, Harrie; Coeleveld, Katja; van Rijen, Mattie H P; Lafeber, Floris P J G; Mastbergen, Simon C

    2017-03-01

    Several experimental models of osteoarthritis in rats are used to study the pathophysiology of osteoarthritis. Many mechanically induced models have the limitation that permanent joint instability is induced by, for example, ligament transection or meniscal damage. This permanent instability will counteract the potential beneficial effects of therapy. The groove model of osteoarthritis uses a one-time trigger, surgically induced cartilage damage on the femoral condyles, and has been validated for the canine tibia-femoral compartment. The present study evaluates this model for the rat knee joint. The articular cartilage of the weight bearing surface of both femoral condyles and trochlea were damaged (grooved) without damaging the underlying subchondral bone. Severity of joint degeneration was histologically assessed, in addition to patella cartilage damage, and subchondral bone characteristics by means of (contrast-enhanced) micro-CT. Mild histological degeneration of the surgically untouched tibial plateau cartilage was observed in addition to damage of the femoral condyles, without clear synovial tissue inflammation. Contrast enhanced micro-CT demonstrated proteoglycan loss of the surgically untouched patella cartilage. Besides, a more sclerotic structure of the subchondral bone was observed. The tibia-femoral groove model in a rat results in mild knee joint degeneration, without permanent joint instability and joint inflammation. This makes the rat groove model a useful model to study the onset and progression of post-traumatic non-inflammatory osteoarthritis, creating a relatively sensitive model to study disease modifying osteoarthritic drugs. © 2016 The Authors. Journal of Orthopaedic Research published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 35:496-505, 2017.

  13. Coxa vara with proximal femoral growth arrest in patients who had neonatal extracorporeal membrane oxygenation.

    Science.gov (United States)

    DiFazio, Rachel L; Kocher, Minider S; Berven, Sigurd; Kasser, James

    2003-01-01

    This is a retrospective review of four patients in whom a pattern of coxa vara with proximal femoral growth arrest and metaphyseal irregularities developed. These patients were all treated with neonatal extracorporeal membrane oxygenation and presented with a progressive gait disturbance and pain, leg-length discrepancy, and limited abduction. Imaging revealed coxa vara with proximal femoral growth arrest. Two patients (three hips) underwent proximal femoral valgus osteotomy, one patient underwent fixation of a femoral neck fracture with subsequent greater trochanter transfer, and one patient is being observed. This case series suggests an association between neonatal extracorporeal membrane oxygenation and this unusual pattern of coxa vara with proximal femoral growth arrest.

  14. Are component positioning and prosthesis size associated with hip resurfacing failure?

    Directory of Open Access Journals (Sweden)

    Seyler Thorsten M

    2010-10-01

    Full Text Available Abstract Background Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. Methods We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months. Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. Results Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters. Conclusions These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve.

  15. DUAL MOBILITY ACETABULAR COMPONENT AS A WAY TO PREVENT HEAD DISLOCATION OF THE HIP

    Directory of Open Access Journals (Sweden)

    V. A. Shilnikov

    2016-01-01

    Full Text Available Prevention of femoral head dislocation is becoming one of the most important tasks in view of increased number of total hip replacement procedures throughout the world. The purpose of the present work is to acquaint the surgeons with possibilities and the first experience of dual mobility acetabular component application as the most up-to-date solution to prevent dislocation of the femoral head in primary or revision arthroplasties. The paper is based on the literature data and presents a critical analysis of the causes of femoral head dislocation during hip replacement. The authors considered historical aspects and the first outcomes of dual mobility use in the European and Western countries, as well as own positive clinical experience with dual mobility system during a study of 36 patients with an increased risk of femoral head dislocation.

  16. MULTICENTRIC GIANT CELL TUMOR OF IPSILATERAL ACETABULUM AND FEMORAL HEAD WITH PATHOLOGICAL FRACTURE OF FEMORAL NECK: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Jayant

    2015-02-01

    Full Text Available INTRODUCTION: Multicentric Giant Cell Tumor is extremely rare; here we are presenting a case of pathological neck femur fracture in case of multicentric giant cell tumor involving ipsilateral acetabulum along with femoral head and neck. CASE PRESENTATION: 24 years old male presented with pain in groin region and inability to walk after he fell down while walking. He had pain in left groin on weight bearing for last six months. Radiological examination shows pathological trans - cervical femoral neck fracture with sub - articular lytic lesion in femoral head and neck suggestive of Giant cell tumor. MRI has been done to define the extent of involvement and to rule out soft tissue infiltration. Fine needle aspiration cytology which was done through anterior route was inconclusive. After review of literature, patient has been planned for excisional biopsy and un - cemented total hip arthroplasty. Intra - operatively, frozen section confirms the giant cell tumor and surprisingly acetabulum was found to be involved which was curetted and hydrogen - peroxide treated. Post - operatively, patient was pain - free with good range of movements at hip. CONCLUSION: Giant cell tumor involving femoral head and neck with pathological fracture though uncommon, but may present as multicentric with acetabular involvement.

  17. Transtrochanteric rotational osteotomy for avascular necrosis of the femoral head after unstable slipped capital femoral epiphysis: 10-year clinical results.

    Science.gov (United States)

    Nakashima, Yasuharu; Yamamoto, Takuaki; Fukushi, Jun-Ichi; Motomura, Goro; Hamai, Satoshi; Kohno, Yusuke; Iwamoto, Yukihide

    2016-11-01

    Avascular necrosis of the femoral head (AVN) is the most serious complication after unstable slipped capital femoral epiphysis (SCFE), and is often unsalvageable. We report a minimum 10 years of clinical results for transtrochanteric rotational osteotomy of the femoral head (TRO) for AVN. This study included 7 patients (7 hips) with a mean age at surgery of 13.3 years, and the follow-up period was 15.8 years. All patients had prior treatment via closed reduction and pinning of the unstable SCFE, and showed severely collapsed femoral heads. The direction of rotation was anterior in 3 hips and posterior in 4. The Merle d'Aubigné-Postel score (MDPS) was used for clinical assessment, and joint degeneration was assessed with the Kellgren and Lawrence classification (KL-grade). The spherical intact area of the femoral head was moved to the weight-bearing portion, and subluxation was corrected via rotation combined with intentional varus positioning. The mean MDPS improved from 10.3 points to 15.6 points at 5 years, and it was maintained at 15.0 points by 10 years; 3 hips were excellent, 1 was good, 2 were fair, and 1 showed poor outcomes. No patient experienced re-collapse after TRO or required conversion to hip replacement or arthrodesis. After 10 years, degenerative changes became evident over time, and 2 hips progressed to KL-4 with a decreased MDPS. Although some joint degeneration is inevitable in the long-term, TRO is an effective salvage procedure for treating AVN after unstable SCFE. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  18. Electronic components

    CERN Document Server

    Colwell, Morris A

    1976-01-01

    Electronic Components provides a basic grounding in the practical aspects of using and selecting electronics components. The book describes the basic requirements needed to start practical work on electronic equipment, resistors and potentiometers, capacitance, and inductors and transformers. The text discusses semiconductor devices such as diodes, thyristors and triacs, transistors and heat sinks, logic and linear integrated circuits (I.C.s) and electromechanical devices. Common abbreviations applied to components are provided. Constructors and electronics engineers will find the book useful

  19. Comparison of conforming and nonconforming retrieved glenoid components.

    Science.gov (United States)

    Nho, Shane J; Ala, Owen L; Dodson, Christopher C; Figgie, Mark P; Wright, Timothy M; Craig, Edward V; Warren, Russell F

    2008-01-01

    The purpose of this study was to compare differences in wear performance of conforming and nonconforming glenoid designs, using clinical, radiographic, and retrieved polyethylene glenoid component outcome Sixty-three glenoids met the study criteria, and each glenoid was assigned to the conforming group (if the radii of curvature of the humeral and glenoid components were identical) or the nonconforming group (if a mismatch existed between the radii of curvature). The mean length of implantation was 5.6 +/- 5.5 years in the conforming group and 3.1 +/- 3.1 years for the nonconforming group (P conforming group and 2.4 +/- 1.2 in the nonconforming one (P conforming group had greater abrasion and delamination scores (P conformity contributes to differences observed from retrieved polyethylene glenoid components, which are consistent with differences in performance that may influence loosening.

  20. Fractura por fatiga de un tallo de revisión femoral modular cónico estriado de fijación distal.

    Directory of Open Access Journals (Sweden)

    Martin Buttaro

    2013-03-01

    Full Text Available 1. Engelbrecht E, Heinert K. Klassifikation und Behandlungsrichtlinien von Knochensubsanzverlusten bei Revisionsoperationen am Huftgelenk mittelfrsige Ergebnisse. Primare und Revisionsalloarthroplastik Hrsg-Endo-Klinik, Hamburg: Springer-Verlag, Berlin; 1987:189. 2. Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 1954;36:451. 3. Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mat Res 1983;17:829. 4. Carlsson AS, Gentz CF, Stenport J. Fracture of the femoral prosthesis in total hip replacement according to Charnley. Acta Orthop Scand 1977;48:650-5. 5. Chao EYS, Coventry MB. Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. J Bone Joint Surg Am 1981;63:1078-94. 6. Charnley J. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthop 1975;111:105. 7. Buttaro M, Mayor M, Van Citters D, Piccaluga F. Fracture of a proximally modular, distally fluted uncemented implant with diaphyseal fixation. J Arthroplasty 2007;22(5:780-3. 8. Bohm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg Am 2001;83(7:1023. 9. Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am 1997;79(12:1842.

  1. Correlation between baseline femoral neck marrow status and the development of femoral head osteonecrosis in corticosteroid-treated patients: A longitudinal study by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vande Berg, Bruno C. [Radiology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium)]. E-mail: vandeberg@rdgn.ucl.ac.be; Gilon, Raphael [Radiology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium); Malghem, Jacques [Radiology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium); Lecouvet, Frederic [Radiology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium); Depresseux, Genevieve [Rheumatology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium); Houssiau, Frederic A. [Rheumatology Department, Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium)

    2006-06-15

    Objective: To test the hypothesis that the development of corticosteroid (CS)-associated femoral head osteonecrosis (ON) is influenced by baseline femoral neck marrow status. Patients and methods: The population consisted of 20 untreated patients with a newly diagnosed rheumatic disease in whom a standardized CS regimen was planned. Before CS treatment, baseline femoral neck marrow status was determined by magnetic resonance (MR) imaging on T1-weighted images (proportion of surface area of femoral neck and intertrochanteric area occupied by fatty marrow; index of marrow conversion [IMC]) and on a quantitative MR sequence (bulk T1 values of femoral head and neck). The presence of ON was assessed by coronal T1-weighted MR images of the hips at 6 and 12 months. Results: None of the patients suffered from ON at baseline. Four patients (20%) developed bilateral femoral head ON at 6 months. The mean percentage of fat marrow in the femoral neck before treatment was significantly higher in ON-positive than in ON-negative patients (p = 0.0025). The mean baseline femoral neck IMC value, which parallels the degree of red to yellow marrow conversion, was higher in ON-positive than in ON-negative patients (p = 0.089). The mean baseline bulk T1 value of the femoral neck (but not of the femoral head), which inversely correlates with the amount of fat marrow, was significantly shorter in ON-positive than in ON-negative patients (p = 0.0298). Conclusion: The development of CS-associated femoral head ON is correlated with a high fat content in the proximal femur before CS therapy.

  2. The influence of acetabular inclination angle on the penetration of polyethylene and migration of the acetabular component: a prospective, radiostereometric study on cemented acetabular components.

    Science.gov (United States)

    Kadar, T; Furnes, O; Aamodt, A; Indrekvam, K; Havelin, L I; Haugan, K; Espehaug, B; Hallan, G

    2012-03-01

    In this prospective study we studied the effect of the inclination angle of the acetabular component on polyethylene wear and component migration in cemented acetabular sockets using radiostereometric analysis. A total of 120 patients received either a cemented Reflection All-Poly ultra-high-molecular-weight polyethylene or a cemented Reflection All-Poly highly cross-linked polyethylene acetabular component, combined with either cobalt-chrome or Oxinium femoral heads. Femoral head penetration and migration of the acetabular component were assessed with repeated radiostereometric analysis for two years. The inclination angle was measured on a standard post-operative anteroposterior pelvic radiograph. Linear regression analysis was used to determine the relationship between the inclination angle and femoral head penetration and migration of the acetabular component. We found no relationship between the inclination angle and penetration of the femoral head at two years' follow-up (p = 0.9). Similarly, our data failed to reveal any statistically significant correlation between inclination angle and migration of these cemented acetabular components (p = 0.07 to p = 0.9).

  3. Mechanisms Underlying Enhanced Noradrenaline-Induced Femoral Arterial Contractions of Spontaneously Hypertensive Rats: Involvement of Endothelium-Derived Factors and Cyclooxygenase-Derived Prostanoids.

    Science.gov (United States)

    Matsumoto, Takayuki; Watanabe, Shun; Iguchi, Maika; Ando, Makoto; Oda, Mirai; Nagata, Mako; Yamada, Kosuke; Taguchi, Kumiko; Kobayashi, Tsuneo

    2016-01-01

    We investigated the relationship between noradrenaline (NAd)-induced contractions, endothelial function, and hypertension in femoral arteries isolated from spontaneously hypertensive rats (SHR). In the femoral arteries of SHR, vs. age-matched control Wistar Kyoto (WKY) rats, contractions induced by NAd were increased. These effects were enhanced by endothelial denudation, which abolished the differences between the two groups. NAd-induced contractions were enhanced by nitric oxide (NO) synthase inhibition, and further increased by the blockade of endothelium-derived hyperpolarizing factor (EDHF). Conversely, NAd-induced contractions were inhibited by cyclooxygenase (COX) inhibition. In addition, in SHR arteries, acetylcholine-induced relaxation was reduced, and components of endothelium-derived factors were altered, such as increased COX-derived vasoconstrictor prostanoids, reduced EDHF, and preserved NO-mediated relaxation. In the femoral arteries of SHR, the production of prostanoids [6-keto prostaglandin (PG)F1α (a metabolite of prostacyclin (PGI2), PGE2, and PGF2α] and COX-2 protein were increased compared with that in WKY rats. By contrast, contractions induced by beraprost (a stable PGI2 analogue), PGE2, and U46619 (thromboxane/prostanoid receptor agonist) were similar between the SHR and WKY groups. Thus, NAd-induced femoral arterial contractions are augmented in SHR resulting from endothelial dysfunction and increased COX-derived vasoconstrictor prostanoid levels.

  4. Temporary total hip arthroplasty-like spacer for treating an infected periprosthetic femoral fracture using a long stem: A case report.

    Science.gov (United States)

    Kim, Youngwoo; Katsura, Yoshiaki; Kasahara, Nina; Kasahara, Takashi; Kanamura, Masashi; Kawanabe, Keiichi

    2017-01-01

    Infected periprosthetic femoral fractures are among the most complex and significant complications of total hip arthroplasty (THA). We report the novel use of a temporary THA-like spacer for treating an infected periprosthetic femoral fracture after revision surgery using a long stem. We present a 72-year-old woman sustained a left infected periprosthetic femoral fracture after revi - streptococci in the culture sample. On suspicion of a periprosthetic joint infection, we planned a two-stage procedure. We used a temporary THA-like spacer comprising the removed femoral long stem, which was autoclaved and then reimplanted, and applied a new polyethylene acetabular liner. Both components were cemented in place with antibioticloaded bone cement, without applying strong pressure. Pain control waseasily achieved postoperatively because the fracture had been stabilized early. The THA-like spacer was stable, and allowed a good range of motion without pain. She was allowed to move with a wheelchair and was walk with partial weight bearing without pain. Seven week after the initial THAlike spacer placement, we performed a revision THA after successful control of infection. At the 1-year follow-up, the patient remained free of infection. Temporary antibiotic-loaded cement-coated THA-like spacer using a long stem facilitated the eradication of infection, fracture stabilization, and enables partial weight bearing without pain. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Malformação ílio-femoral

    OpenAIRE

    2006-01-01

    Durante uma dissecção de rotina realizada em um cadáver do sexo masculino com 65 anos de idade foi constatada malformação arterial iliofemoral. A aorta abdominal estava consideravelmente deslocada lateralmente e também bifurcava em nível mais alto. A artéria ilíaca comum dividia-se uma vértebra acima do nível normal e a artéria femoral dava origem à artéria femoral profunda aproximadamente l,2 cm abaixo do ligamento inguinal, o que é consideravelmente proximal ao seu nível normal. Aqui nós ap...

  6. Confronting hip resurfacing and big femoral head replacement gait analysis

    Directory of Open Access Journals (Sweden)

    Panagiotis K. Karampinas

    2014-03-01

    Full Text Available Improved hip kinematics and bone preservation have been reported after resurfacing total hip replacement (THRS. On the other hand, hip kinematics with standard total hip replacement (THR is optimized with large diameter femoral heads (BFH-THR. The purpose of this study is to evaluate the functional outcomes of THRS and BFH-THR and correlate these results to bone preservation or the large femoral heads. Thirty-one patients were included in the study. Gait speed, postural balance, proprioception and overall performance. Our results demonstrated a non-statistically significant improvement in gait, postural balance and proprioception in the THRS confronting to BFH-THR group. THRS provide identical outcomes to traditional BFH-THR. The THRS choice as bone preserving procedure in younger patients is still to be evaluated.

  7. Subchondral insufficiency fracture of the femoral head after liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, Kenyu; Yamamoto, Takuaki; Nakashima, Yasuharu; Mawatari, Taro; Motomura, Goro; Ikemura, Satoshi; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Fukuoka (Japan)

    2009-09-15

    A 53-year-old woman developed a subchondral insufficiency fracture of the right femoral head after undergoing a liver transplantation. Radiographs obtained at her first visit demonstrated a slight subchondral collapse in the superolateral portion of the femoral head. Magnetic resonance imaging (MRI) disclosed an irregular, discontinuous, low-intensity band on the T1-weighted image. After 7 months of conservative treatment, the hip pain and the radiograph abnormalities had both disappeared. On the follow-up T1-weighted MR image obtained 17 months after the onset, the band of low signal intensity was not obvious. A subchondral insufficiency fracture is one of the diagnoses to be considered in patients presenting with hip pain after a liver transplantation. (orig.)

  8. Tibial tubercle osteotomy for patello-femoral joint disorders.

    Science.gov (United States)

    Hall, Matthew J; Mandalia, Vipul I

    2016-03-01

    Tibial tubercle osteotomy has a long history in the management of patella instability and patello-femoral arthritis. This review aims to provide a comprehensive review of the literature describing the biomechanics of the patello-femoral joint and the rationale behind the use of the tibial tubercle osteotomy in modern day practice. Several different tibial tubercle osteotomies are available and we aim to detail the concepts behind their use and the subsequent clinical results. With continued developments of chondrocyte implantation techniques, the potential to fill defects on the chondral surface of either the patella or trochlea in conjunction with a tibial tubercle osteotomy may well become more commonplace in a group that is commonly young and difficult to manage. Level of evidence III.

  9. Femoral anatomy of Aegyptopithecus zeuxis, an early oligocene anthropoid.

    Science.gov (United States)

    Ankel-Simons, F; Fleagle, J G; Chatrath, P S

    1998-08-01

    Three partial femora from Quarries I and M of the early Oligocene Jebel Qatrani Formation in the Fayum of Egypt are attributed to Aegyptopithecus zeuxis on the basis of their appropriate size and anthropoid morphology. Compared with extant catarrhines, Aegyptopithecus is unusual in having a distinct gluteal tuberosity (third trochanter) and a relatively deep distal femoral articulation. In the estimated neck angle, Aegyptopithecus resembles arboreal quadrupeds rather than either leaping or suspensory primates. It seems likely that the femur of this species was relatively robust and short for its body mass. In aspects of its femoral anatomy, Aegyptopithecus is quite different from the parapithecid Apidium and more similar to Catopithecus from late Eocene deposits of the Fayum, and also to small hominoids from the Miocene of East Africa.

  10. A Case of Femoral Fracture in Klippel Trenaunay Syndrome

    Directory of Open Access Journals (Sweden)

    Sam Nahas

    2014-01-01

    Full Text Available We present a case of Klippel Trenaunay syndrome (KTS who presented with severe bilateral knee osteoarthritis (OA. Preoperative planning was commenced for a total knee replacement (TKR. Whilst on the waiting list the patient suffered a fall and sustained a complete femoral diaphysis fracture. Conservative management in the form of skin traction was initially chosen as significant extra- and intramedullary vascular malformations posed an increased risk of perioperative bleeding. This failed to progress to union, and so open reduction and internal fixation was performed. This subsequently resulted in on-going delayed union, which was subsequently managed with low intensity pulsed ultrasound (LIPUS, otherwise known as Exogen (Bioventus. exogen. Secondary exogen, 2012. There are only two previous documented cases of femoral fracture in KTS. This is the first report of a patient with this rare syndrome receiving this treatment. We discuss the management of fracture in this challenging group of patients.

  11. Nonunion of coronal shear fracture of femoral condyle

    Directory of Open Access Journals (Sweden)

    Singh Ajay Pal

    2011-06-01

    Full Text Available 【Abstract】Isolated coronal fractures of femoral condyle are rare in adults and nonunion of Hoffa fracture is reported only a few times in the literature. We analyzed six cases of nonunion of Hoffa fractures over a period of three years. Three patients were treated conservatively and three patients had fixation failures. Delay of presentation was 2 months to one year. Treatment protocol consisted of open reduction, excision of pseudoarthrosis, bone grafting and internal fixation along with knee arthrolysis. Union was achieved in all patients at mean 16 weeks. The treatment of nonunion of Hoffa fractures requires careful preoperative planning and meticulous surgical technique. The literature regarding the controversies in fracture management and surgical technique are reviewed. Key words: Femoral fracture; Fracture fixation, internal; Retrospective studies

  12. Varus distal femoral osteotomy in young adults with valgus knee

    Science.gov (United States)

    Omidi-Kashani, Farzad; Hasankhani, Ibrahim G; Mazlumi, Mahdi; Ebrahimzadeh, Mohamad H

    2009-01-01

    Background Musculoskeletal disorders specially knee osteoarthritis are the most common causes of morbidity in old patients. Disturbance of the mechanical axis of the lower extremity is one of the most important causes in progression of knee osteoarthritis. The purpose of the present study was to analyze the surgical results of distal femoral varus osteotomy in patients with genu valgum. Methods In this study, after recording history and physical examination, appropriate radiographs were taken. We did varus distal femoral osteotomy by standard medial subvastus approach and 90-angle blade plate fixation then followed the patients clinically and radiographically. Results This study was done on 23 knees (16 patients) age 23.3 years (range, 17 to 41 years). The mean duration of following up was 16.3 months (range, 8 to 25 months). Based on paired T test, there were statistically significant difference between pre- and postoperative tibiofemoral and congruence angles (p genu valgum correction, the patella should be stabilized simultaneously. PMID:19435527

  13. Computer assisted measurement of femoral cortex thickening on radiographs

    Science.gov (United States)

    Yao, Jianhua; Liu, Yixun; Chen, Foster; Summers, Ronald M.; Bhattacharyya, Timothy

    2013-03-01

    Radiographic features such as femoral cortex thickening have been frequently observed with atypical subtrochanteric fractures. These features may be a valuable finding to help prevent fractures before they happen. The current practice of manual measurement is often subjective and inconsistent. We developed a semi-automatic tool to consistently measure and monitor the progress of femoral cortex thickening on radiographs. By placing two seed points on each side of the femur, the program automatically extracts the periosteal and endosteal layers of the cortical shell by active contour models and B-spline fitting. Several measurements are taken along the femur shaft, including shaft diameter, cortical thickness, and integral area for medial and lateral cortex. The experiment was conducted on 52 patient datasets. The semi-automatic measurements were validated against manual measurements on 52 patients and demonstrated great improvement in consistency and accuracy (p<0.001).

  14. Femoral lengthening during hip resurfacing arthroplasty: a new surgical procedure.

    Science.gov (United States)

    Vasseur, L; Ayoub, B; Mesnil, P; Pasquier, G; Migaud, H; Girard, J

    2015-04-01

    Correction of leg length discrepancy during hip arthroplasty is a technical challenge. Although resurfacing proposed to young subjects presents a number of advantages (stability, bone stock, etc.), it does not correct leg length discrepancy. We propose an original femoral lengthening technique concomitant to resurfacing performed through the same approach, consisting in a Z-shaped subtrochanteric osteotomy. Resurfacing was performed first and the femoral and acetabular reaming material was used for autografting. The series comprised five cases followed for a mean 42.2 months (range, 33-64 months). The mean surgical time was 100 min (range, 76-124 min). Weightbearing was authorized in all cases at the 8th week. The mean lengthening was 32 mm (range, 25-40 mm). Healing was observed in all cases. This surgical technique, reserved for very young subjects who accept an 8-week postoperative period without weightbearing, can be proposed in cases with substantial preoperative leg length discrepancy.

  15. Femoral approach: an exceptional alternative for permanent pacemaker implantation.

    Science.gov (United States)

    Tereno Valente, Bruno; Conceição, José M; Nogueira da Silva, Manuel; M Oliveira, Mário; S Cunha, Pedro; Lousinha, Ana; Galrinho, Ana; C Ferreira, Rui

    2014-05-01

    The classic transvenous implantation of a permanent pacemaker in a pectoral location may be precluded by obstruction of venous access through the superior vena cava or recent infection at the implant site. When these barriers to the procedure are bilateral and there are also contraindications or technical difficulties to performing a thoracotomy for an epicardial approach, the femoral vein, although rarely used, can be a viable alternative. We describe the case of a patient with occlusion of both subclavian veins and a high risk for mini-thoracotomy or videothoracoscopy, who underwent implantation of a permanent single-chamber pacemaker via the right femoral vein. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  16. Development of Phantom Limb Pain after Femoral Nerve Block

    Directory of Open Access Journals (Sweden)

    Sadiah Siddiqui

    2014-01-01

    Full Text Available Historically, phantom limb pain (PLP develops in 50–80% of amputees and may arise within days following an amputation for reasons presently not well understood. Our case involves a 29-year-old male with previous surgical amputation who develops PLP after the performance of a femoral nerve block. Although there have been documented cases of reactivation of PLP in amputees after neuraxial technique, there have been no reported events associated with femoral nerve blockade. We base our discussion on the theory that symptoms of phantom limb pain are of neuropathic origin and attempt to elaborate the link between regional anesthesia and PLP. Further investigation and understanding of PLP itself will hopefully uncover a relationship between peripheral nerve blocks targeting an affected limb and the subsequent development of this phenomenon, allowing physicians to take appropriate steps in prevention and treatment.

  17. Blood flow and microdialysis in the human femoral head

    DEFF Research Database (Denmark)

    Bøgehøj, Morten; Emmeluth, Claus; Overgaard, Søren

    2007-01-01

    BACKGROUND: If it would be possible to detect lack of flow and/or the development of ischemia in bone, we might have a way of predicting whether a broken bone will heal. We established microdialysis (MD) and laser Doppler (LD) flow measurement in the human femoral head in order to be able to detect...... ischemia and measure changes in blood flow. MATERIAL AND METHODS: In 9 patients undergoing total hip arthroplasty for primary osteoarthrosis, two MD catheters were inserted into the femoral head through two drill holes after the blood flow had been visualized by LD. Then primary samples were collected...... detected within 2 h of cessation of blood flow in most patients....

  18. Coexisting ipsilateral right femoral hernia and incarcerated obturator hernia.

    Science.gov (United States)

    Seppälä, Toni T; Tuuliranta, Mikko

    2015-02-25

    Obturator hernia (OH) is an uncommon cause of bowel obstruction and described in elderly females in the literature. The treatment has traditionally been laparotomy because of an acute nature of the condition. However, because of old age and comorbidities that OH is associated with, general anaesthesia may need to be avoided. In the current case, a transinguinal preperitoneal approach and management are presented after delayed preoperative diagnosis of bowel obstruction caused by a coexisting right incarcerated OH and ipsilateral non-reducible femoral hernia. A 91-year-old woman had a 6-day history of nausea and vomiting. She was referred to surgery because of persisting vomiting, but without any abdominal pain. A CT scan showed a hernia in the right groin area but the diagnosis was delayed. The hernias were repaired using a preperitoneal transinguinal approach. Bowel resection was not needed. The obturator canal and the femoral ring were both covered by a Bard Polysoft patch.

  19. Importance of sagittal MR imaging in nontraumatic femoral head osteonecrosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Alice S. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Wells, Lawrence [Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2008-11-15

    In nontraumatic femoral head osteonecrosis, characterization of femoral head collapse is important in staging disease progression and planning treatment. Few prior studies have quantitatively compared the ability of sagittal and coronal MR images to detect femoral head collapse. We hypothesized that sagittal MR images show a greater degree and angular span of femoral head collapse than coronal images. We reviewed 38 hip MRI scans of nontraumatic femoral head osteonecrosis from 34 pediatric patients. In both sagittal and coronal images, the maximal extent and angular location along with the angular span of the femoral head collapse were measured. Differences were evaluated using a paired t-test. The extent of bone and cartilage loss from the femoral head was evaluated. Sagittal MR images showed 29% maximal femoral head radius collapse, whereas coronal images showed 16% collapse (P<0.001). Sagittal images showed a larger angular span of collapse (115 ) than coronal images (55 , P<0.001). Sagittal images showed greater epiphyseal bone loss in the anterior than in the posterior portion (P<0.001), whereas coronal images did not show a significant difference in bone loss between the medial and lateral portion (P=0.32). Sagittal images show greater femoral head collapse than coronal images in nontraumatic femoral head osteonecrosis. (orig.)

  20. VARIATIONS IN ORIGIN OF FEMORAL NERVE FROM THE LUMBER PLEXUS (A CADAVERIC STUDY

    Directory of Open Access Journals (Sweden)

    Dr. Gurbachan Singh Gindha

    2015-04-01

    Full Text Available The variations in origin of femoral nerve from lumbar plexuses is very much common. The normal root value of origin of femoral nerve is L2, L2 and L4. It can be prefixed or postfixed. Mostly the femoral nerve is used for the nerve block in several surgeries and is vulnerable to compression in tight ilio-psoas compartment. The knowledge of origin and variations of femoral nerve in iliac fossa is important for anatomists, anaesthetists and surgeons to prevent iatrogenic femoral nerve injuries.3 0 embalmed with 10% formal in and fixed cadavers were dissecte donboth sides and 60 lumbar plexuses with their branches formed the mat e r i a l f o r t h e study. The p s oas major muscle was dissected to see the formation of femoral nerve from theroots and to observe the variations in the formation of femoral nerve. The aim of this study was to look for the variations in origin and branching pattern of the femoral nerve in the iliac fossa and proper exposure of the femoral nerve in the femoral triangle.

  1. Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

    Directory of Open Access Journals (Sweden)

    Xiu-yun Su

    2015-01-01

    Full Text Available Purpose. To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D space. Methods. Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium. The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. Results. The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r=0.24, p<0.01 and between the femoral length and the isthmus height (r=0.6, p<0.01. Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. Conclusion. The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

  2. Successful Return to Sport Following Distal Femoral Varus Osteotomy

    Science.gov (United States)

    Voleti, Pramod Babu; Degen, Ryan; Tetreault, Danielle; Krych, Aaron John; Williams, Riley J.

    2016-01-01

    Objectives: Distal femoral varus osteotomy is an effective treatment for unloading valgus knee malalignment; however, there is limited evidence on the ability for patients to return to athletics following this procedure. The purpose of this study is to report the functional outcomes and return to sport for athletic patients that underwent distal femoral varus osteotomy. Methods: A consecutive series of athletic patients that had undergone distal femoral varus osteotomy for symptomatic lateral compartment overload and valgus knee malalignment were prospectively reviewed. All patients had a minimum of 2-year follow-up. Radiographs were assessed to determine pre-operative and post-operative alignment. Details regarding sport of interest, ability to return to sport, and timing of return were obtained from the patients. Prospective institutional registries were utilized to collect pre-operative and post-operative Marx Activity Scale and International Knee Documentation Committee Subjective Knee Evaluation Form (IKDC) scores; these values were compared using paired t-tests with p allografts, 2 partial lateral meniscectomies, 1 lateral meniscus allograft transplantation, and 1 revision anterior cruciate ligament reconstruction. All patients were able to successfully return to their sport of choice (4 soccer, 2 softball, 2 running, 1 football, 1 basketball, 1 ice hockey, 1 volleyball, 1 rowing) at a mean of 11 months (range: 9-13). Furthermore, all 13 patients demonstrated an improvement in both Marx Activity Scale and IKDC scores after surgery. The mean improvement in Marx Activity Scale was 7 (mean pre-op: 4, mean post-op: 11, p ligamentous pathology is addressed. Therefore, distal femoral varus osteotomy should be considered in the athletic population for correction of symptomatic valgus knee malalignment.

  3. Slipped capital femoral epiphysis caused by neurogenic heterotopic ossification.

    Science.gov (United States)

    Chang, Sam Yeol; Yoo, Won Joon; Park, Moon Seok; Chung, Chin Youb; Choi, In Ho; Cho, Tae-Joon

    2013-11-01

    Slipped capital femoral epiphysis (SCFE) is rare in nonambulatory patients, as mechanical factors play important roles in the development of the disease. We report a case of SCFE, which occurred in a 12-year-old girl with a nonambulatory status after cerebral infarction. SCFE occurred after she received passive range of motion exercise and extracorporeal shock wave treatment for neurogenic heterotopic ossification around the hip joint. The patient was successfully managed by a stepwise approach, with radiological and clinical improvements.

  4. Magnetic resonance imaging of idiopathic osteonecrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Yamazoe, Shoichi [Kyoto Prefectural Univ. of Medicine (Japan)

    1995-02-01

    Idiopathic osteonecrosis of the femoral head (IONF) can result in disability due to bone collapse and destruction. Therefore, early diagnosis of IONF and prognosis assessment are essential for treatment planning. This study investigated the early characteristic pattern of IONF on magnetic resonance imaging (MRI) and its correlation to the prognosis of the femoral head. MRI was performed repeatedly on fifty-one patients who had undergone renal transplantation. Three abnormal patterns were found in the T{sub 1}-weighted images: a band-like low-signal pattern (band pattern), an irregular low-signal pattern (mottled pattern), and a homogeneous low-signal area localized in the subchondral region (homogeneous pattern). Abnormal changes were detected in thirteen patients; twenty-three hips (25.5%). Most changes were evident within six months after transplantation. The earliest was found six weeks after transplantation. A band pattern was the initial finding in all hips showing abnormal changes. The band pattern did not spread peripherally as time passed. There was no progression from a mottled or homogeneous pattern to a band pattern either. Band-like patterns were subclassified into four types: MR-A, MR-B, MR-C and MR-D. Each of types according to the size and location of the band in relation to the weight bearing portion of the acetabulum was correlated to the prognosis of the femoral head. Three fourths of femoral heads with MR-C resulted in collapse on roentgenographs. These results show that MRI is useful for the diagnosis and evaluation of prognosis in IONF. (author).

  5. Subchondral insufficiency fracture of the femoral head in younger adults

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Takuaki; Nakashima, Yasuharu; Shuto, Toshihide; Jingushi, Seiya; Iwamoto, Yukihide [Graduate School of Medical Sciences, Kyushu University, Department of Orthopaedic Surgery, Fukuoka (Japan)

    2007-06-15

    We report two cases of subchondral insufficiency fracture of the femoral head observed in younger adults without any history of overexertion. In both cases, MRI revealed an irregular, discontinuous low-intensity band on the T1-weighted images. Both patients were treated operatively, and histological examination confirmed the diagnosis of subchondral fracture. A diagnosis of subchondral insufficiency fracture needs to be put in as one of the diagnoses in younger patients with a hip pain. (orig.)

  6. Does Tranexamic Acid Reduce Bleeding during Femoral Fracture Operation?

    Directory of Open Access Journals (Sweden)

    Mohammad Haghighi

    2017-03-01

    Full Text Available Background:Proximal Femoral shaft fractures are commonly associated with marked blood loss which can lead topostoperative acute anemia and some other complications.Tranexamic acid (TA is an antifibrinolytic medication that reduces intra-and postoperative blood loss and transfusionrequirements during some elective surgeries (1-3.The aim of this study is to evaluate the effect of intravenous Tranexamic acid (TA on intraoperative blood loss and asubsequent need for transfusion in patients who were undergoing surgery for femoral shaft fractures in trauma setting.Methods:Thirty-eight ASA grade I-II patients undergoing proximal femoral shaft fracture surgery with intra medullarynailing were included in this double blind randomized controlled clinical trial. They were allocated into two groups. GroupI, the intervention group with eighteen patients received 15 mg/kg (TA via intravenous infusion before surgical incision.Patients in the placebo group received an identical volume of normal saline.Hemoglobin level was measured four hours before and after the surgeries. Postoperative blood loss and hemoglobinchange as well as transfusion rates and volumes were compared between the two groups.Results:Mean Percentage fall in hemoglobin after surgery were 1.75±0.84 and 2.04±1.9 in the study and placebo groups,respectively (P=0.570. Hemoglobin loss was higher in the placebo group. Transfusion rates was lower in TA group(5.6% compared to the placebo group (30% (P=0.06. No significant difference in The Allowable Blood Loss during thesurgery was found between the two groups (P=0.894.Conclusion:Preoperative treatment with TA reduces postoperative blood loss and the need for blood transfusion duringtraumatic femoral fracture operation.

  7. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  8. Residual stress around the cortical surface in bovine femoral diaphysis.

    Science.gov (United States)

    Yamada, Satoshi; Tadano, Shigeru

    2010-04-01

    Residual stress in living tissue plays an important role in mechanical strength. We have reported that residual stress exists in the bone tissue of a rabbit's tibiofibula. The purpose of this study is to measure the residual stress around the outer cortical region of bovine femoral diaphysis and to discuss the distribution of the stress. This work proposed the sin(2) psi method of X-ray diffraction to the measurement of residual stresses in bone tissue. In this method, residual stress can be estimated from the variation in the interplanar spacings orientated to a number of directions without the lattice strain in the stress direction. Four-point bending tests of strip specimens taken from bovine femoral diaphysis were carried out during X-ray irradiation in advance. In the proximal, middle, and distal sections of bovine femoral diaphyses, the residual stresses at the cortical surface were measured using characteristic Mo-Kalpha X-rays. The bending tests of strip specimens with X-ray irradiation showed that the method could reliably estimate residual stresses in the bone tissue. The residual stress of the bone axial direction was larger than that of the circumferential direction. The stresses in the middle part of five diaphyses along the bone axial direction were tensile. The maximum stress was 162 MPa at the lateral position and the minimum was 78 MPa at the posterior position. The residual stress in the bone axial direction varies around the circumferential region. In addition, the bone axial distributions of residual stresses were different in the proximal, middle, and distal sections of the individual femur. Furthermore, it was confirmed that residual stress in the bone tissue was released by the cutting out of the specimen. The residual stresses in bone tissue could be measured by this method. The results show that residual stress in the bone axial direction at the cortical surface in bovine femoral diaphysis is tensile and varies around the circumferential

  9. Subtrochanteric Femoral Insufficiency Fracture Following Bisphosphonate Therapy for Osseous Metastases

    OpenAIRE

    Bush, Lisabeth A.; Chew, Felix S.

    2015-01-01

    We present the case of an insufficiency fracture of the femoral shaft in a 61-year-old man who had received bisphosphonate therapy to reduce the fracture risk from lytic renal cell carcinoma metastases to the spine. Approximately 1.5 years after beginning monthly intravenous infusions of zoledronic acid (Zometa), the patient complained of persistent thigh pain. Radionuclide bone scan showed mildly increased activity in the lateral subtrochanteric cortex of the right femur, where there was foc...

  10. Genetic predisposition for femoral neck stress fractures in military conscripts

    OpenAIRE

    Barral Sandra; Sahi Timo; Ruohola Juha-Petri; Solovieva Svetlana; Pihlajamäki Harri; Hartikka Heini; Korvala Johanna; Ott Jürg; Ala-Kokko Leena; Männikkö Minna

    2010-01-01

    Abstract Background Stress fractures are a significant problem among athletes and soldiers and may result in devastating complications or even permanent handicap. Genetic factors may increase the risk, but no major susceptibility genes have been identified. The purpose of this study was to search for possible genetic factors predisposing military conscripts to femoral neck stress fractures. Results Eight genes involved in bone metabolism or pathology (COL1A1, COL1A2, OPG, ESR1, VDR, CTR, LRP5...

  11. Femoral prosthesis subsidence in asymptomatic patients. A stereophotogrammetric assessment.

    Science.gov (United States)

    Chafetz, N; Baumrind, S; Murray, W R; Genant, H K

    1984-01-01

    A radiographic stereophotogrammetric technique (SPG) was used to evaluate quantitatively the presence of early femoral prosthesis subsidence after total hip arthroplasty (THA). This paper focuses on the measurement of subsidence in 12 patients who remained asymptomatic during the first two years after surgery. Only one of these had SPG estimated subsidence in excess of one millimeter at any timepoint. These findings are consistent with the conclusion that early postoperative subsidence is not a common finding among asymptomatic THA patients.

  12. Femoral neck non-union treatment by valgus intertrochanteric osteotomy

    Science.gov (United States)

    Schwartsmann, Carlos Roberto; Spinelli, Leandro de Freitas; Yépez, Anthony Kerbes; Boschin, Leonardo Carbonera; Silva, Marcelo Faria

    2015-01-01

    ABSTRACT OBJECTIVE : The purpose of this study was to evaluate the performance of valgus intertrochanteric osteotomy in femoral neck non-union. METHODS : Forty-two patients with femoral neck fractures with non-union treated using Pauwels' intertrochanteric osteotomy were reviewed. Demographics, time elapsed between fracture and surgery, follow--up, osteosynthesis used, Garden's classification, limb shortening, and x-rays were evaluated. RESULTS : Twenty-two men and 20 women were reviewed. The youngest patient was 18 years old and the oldest 65 years old, with a mean age of 42.4 years (±11.2). The minimum follow-up was 2 years, with a mean of 10.2 years. The average time elapsed between initial fracture and osteotomy was 6.5 months. Twel-ve cases were neglected femoral neck fractures. Nineteen patients were classified as Garden III, and 23 patients as Garden IV. After valgus osteotomy, non-union healing was observed in 38 patients (38/42; 90.4%). Healing of thirty-seven cases of pseudoarthrosis were obtained after the first-attempt osteotomy, and one case required two operations for healing. The osteotomy failed in four cases. Conside-ring the healed osteotomies, good to excellent functional results were achieved in 80.9% (34/42) of the patients. Total hip replacement was subsequently performed in 14.2% (6/42) of the patients for unfavoura-ble outcomes (two for cutting out, two for osteonecrosis, and two for osteoarthritis). CONCLUSIONS : Valgus intertrochanteric osteotomy has a high success rate in archiving healing in femoral neck non-union with good functional results. It is a biological and effective method. Level of Evidence IV, Therapeutic Study. PMID:27057146

  13. Pediatric femoral shaft fractures treated by flexible intramedullary nailing

    Institute of Scientific and Technical Information of China (English)

    K.C.Kapil Mani; R.C.Dirgha Raj; Acharya Parimal

    2015-01-01

    Background:Nowadays pediatric femoral fractures are more commonly managed with operative treatment rather than conservative treatment because of more rapid recovery and avoidance of prolonged immobilization.Children between the ages of 5-13 years are treated either by traction plus hip spica and flexible/elastic stable retrograde intramedullary nail,or external fixators in the case of open fractures.The aim of this study is to evaluate the outcome of pediatric femoral shaft fractures treated by stainless steel flexible intramedullary nail in children between 5 and 13 years of age.Methods:There were 32 cases of femoral shaft fractures which were all fixed with stainless steel flexible intramedullary nail under fluoroscopy.Long leg cast was applied at the time of fixation.Partial weight bearing was started 2 weeks after surgery.Patients were evaluated in follow-up study to observe the alignment of fracture,infection,delayed union,nonunion,limb length discrepancy,motion of knee joint,and time to unite the fracture.Results:We were able to follow up 28 out of 32 patients.The patients were 8.14 years of age on average.The mean hospital stay after operation was 4 days and fracture union time was 9.57 weeks.There were 3 cases of varus angulation,2 cases of anterior angulation,and 4 cases of limb lengthening.Conclusion:Patients aged between 5 and 13 years treated with flexible intramedullary nail for closed femoral shaft fracture have rapid union and recovery,short rehabilitation period,less immobilization and psychological impact,and cost-effective.

  14. Muscle strength and knee range of motion after femoral lengthening

    Science.gov (United States)

    Bhave, Anil; Shabtai, Lior; Woelber, Erik; Apelyan, Arman; Paley, Dror; Herzenberg, John E

    2017-01-01

    Background and purpose Femoral lengthening may result in decrease in knee range of motion (ROM) and quadriceps and hamstring muscle weakness. We evaluated preoperative and postoperative knee ROM, hamstring muscle strength, and quadriceps muscle strength in a diverse group of patients undergoing femoral lengthening. We hypothesized that lengthening would not result in a significant change in knee ROM or muscle strength. Patients and methods This prospective study of 48 patients (mean age 27 (9–60) years) compared ROM and muscle strength before and after femoral lengthening. Patient age, amount of lengthening, percent lengthening, level of osteotomy, fixation time, and method of lengthening were also evaluated regarding knee ROM and strength. The average length of follow-up was 2.9 (2.0–4.7) years. Results Mean amount of lengthening was 5.2 (2.4–11.0) cm. The difference between preoperative and final knee flexion ROM was 2° for the overall group. Congenital shortening cases lost an average of 5% or 6° of terminal knee flexion, developmental cases lost an average of 3% or 4°, and posttraumatic cases regained all motion. The difference in quadriceps strength at 45° preoperatively and after lengthening was not statistically or clinically significant (2.7 Nm; p = 0.06). Age, amount of lengthening, percent lengthening, osteotomy level, fixation time, and lengthening method had no statistically significant influence on knee ROM or quadriceps strength at final follow-up. Interpretation Most variables had no effect on ROM or strength, and higher age did not appear to be a limiting factor for femoral lengthening. Patients with congenital causes were most affected in terms of knee flexion. PMID:27892743

  15. Titanium elastic nailing in pediatric femoral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Singh Roop

    2006-01-01

    Full Text Available Background: The need for operative fixation of pediatric femoral fractures is increasingly being recognised in the present decade. The conventional traction and casting method for management of pediatric femoral fractures is giving way for the operative stabilisation of the fracture. Methods : Thirty five pediatric patients in age group 6-14 years with diaphyseal femoral fractures were stabilised with two titanium nails. Patients were followed up clinically and radiologically for two years. The final results were evaluated using the criteria of Flynn et al. Technical problems and complications associated with the procedure were also analysed. Results : Overall results observed were excellent in 25, satisfactory in 8 and poor in 2 patients. Hospital time averaged 12.30 days in the series. All the fractures healed with an average time to union of 9.6 (6-14.4 weeks. Return to school was early with an average of 7.8 weeks. The soft tissue discomfort near the knee produced by the nails ends was the most common problem encountered. Shortening was observed in three cases and restriction of knee flexion in 5 patients. There was no delayed union, infection or refractures. Per operative technical problems included failure of closed reduction in 2 cases and cork screwing of nails in one case. Conclusion : We believe that with proper operative technique and aftercare TENs may prove to be an ideal implant for pediatric femoral fracture fixation. The most of the complication associated with the procedure are infact features of inexact technique and can be eliminated by strictly adhering to the basic principles and technical aspects.

  16. A low morbidity surgical approach to the sheep femoral trochlea

    Directory of Open Access Journals (Sweden)

    Orth Patrick

    2013-01-01

    Full Text Available Abstract Background The ovine stifle joint is an important location for investigations on the repair of articular cartilage defects in preclinical large animals. The classical medial parapatellar approach to the femoral trochlea is hazardous because of the high risk of postoperative patellar luxation. Here, we describe a low morbidity surgical exposure of the ovine trochlea without the necessity for intraoperative patellar luxation. Methods Bilateral surgical exposure of the femoral trochlea of the sheep stifle joint was performed using the classical medial parapatellar approach with intraoperative lateral patellar luxation and transection of the medial patellar retinaculum in 28 ovine stifle joints. A low morbidity approach was performed bilaterally in 116 joints through a mini-arthrotomy without the need to transect the medial patellar retinaculum or the oblique medial vastus muscle nor surgical patellar luxation. Postoperatively, all 72 animals were monitored to exclude patellar luxations and deep wound infections. Results The novel approach could be performed easily in all joints and safely exposed the distal two-thirds of the medial and lateral trochlear facet. No postoperative patellar luxations were observed compared to a postoperative patellar luxation rate of 25% experienced with the classical medial parapatellar approach and a re-luxation rate of 80% following revision surgery. No signs of lameness, wound infections, or empyema were observed for both approaches. Conclusions The mini-arthrotomy presented here yields good exposure of the distal ovine femoral trochlea with a lower postoperative morbidity than the classical medial parapatellar approach. It is therefore suitable to create articular cartilage defects on the femoral trochlea without the risk of postoperative patellar luxation.

  17. The successful use of peripheral nerve blocks for femoral amputation

    DEFF Research Database (Denmark)

    Bech, B.; Melchiors, J.; Borglum, J.

    2009-01-01

    We present a case report of four patients with severe cardiac insufficiency where peripheral nerve blocks guided by either nerve stimulation or ultrasonography were the sole anaesthetic for above-knee amputation. The patients were breathing spontaneously and remained haemodynamically stable during...... surgery. Thus, use of peripheral nerve blocks for femoral amputation in high-risk patients seems to be the technique of choice that can lower perioperative risk....

  18. Complications Associated With Femoral Cannulation During Minimally Invasive Cardiac Surgery.

    Science.gov (United States)

    Lamelas, Joseph; Williams, Roy F; Mawad, Maurice; LaPietra, Angelo

    2017-06-01

    Different types of cannulation techniques are available for minimally invasive cardiac surgery. At our institution, we favor a femoral platform for most minimally invasive cardiac procedures. Here, we review our results utilizing this cannulation approach. We retrospectively reviewed all minimally invasive valve surgeries that were performed at our institution between January 2009 and January 2015. Operative times, lengths of stay, postoperative complications, and mortality were analyzed. We identified 2,645 consecutive patients. The mean age was 69.7 ± 12.77 years, and 1,412 patients (53.4%) were male. Three hundred fifty-eight patients (13.5%) had a history of cerebrovascular accident, 422 (16%) had previous heart surgery, and 276 (10.4%) had a history of peripheral vascular disease. The procedures performed were isolated aortic valve replacements (42.1%), isolated mitral valve operations (40.6%), tricuspid valve repairs (0.57%), double valve surgery (15%), triple valve surgery (0.3%), and ascending aortic aneurysm resection with and without circulatory arrest (5%). Femoral cannulation and central cannulation were utilized in 2,400 patients (90.7%) and 244 patients (9.3%), respectively. The median aortic cross-clamp time and cardiopulmonary bypass time were 81 minutes (interquartile range, 65 to 105) and 113 minutes (interquartile range, 92 to 142), respectively. The median postoperative hospital length of stay was 6 days (interquartile range, 5 to 9). There were 31 cerebrovascular accidents (1.17%), no aortic dissections, two compartment syndromes, two femoral arterial pseudoaneurysms, and 174 (6.65%) groin wound seromas. The overall 30-day mortality was 57 patients (2.15%). Minimally invasive cardiac surgical procedures utilizing femoral cannulation techniques have a low risk of complications. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Redox Status in Patients with Femoral Neck Fractures

    Directory of Open Access Journals (Sweden)

    Pesic Goran

    2016-09-01

    Full Text Available The femur transfers the body weight from the pelvic bone to the shinbone. Femur fractures are a significant cause of morbidity and mortality among the group of locomotor apparatus injuries, especially in the elderly population. Considering that oxidative stress occurs as a result of increased production of free radicals that damage cell function and cause numerous pathological conditions and diseases, the aim of this study was to investigate oxidative stress parameters in older patients with femoral neck fractures. This clinical study included 70 patients, of which 35 had femoral neck fractures (26 males and 9 females, while the other half of the patients formed the matched control group. Markers of oxidative stress (NO2−, TBARS, H2O2 and O2- and anti-oxidative enzymes (SOD, CAT, and GSH were measured. Results showed that the levels of O2- increased, while levels of NO2-, H2O2 and all the antioxidative enzymes decreased in patients with femoral neck fractures. These findings indicate that fractures cause oxidative stress, probably because of the reduced activity of osteoblasts and the increased activity of osteoclasts.

  20. Hip replacement in femoral head osteonecrosis: current concepts.

    Science.gov (United States)

    Scaglione, Michelangelo; Fabbri, Luca; Celli, Fabio; Casella, Francesco; Guido, Giulio

    2015-01-01

    Osteonecrosis of the femoral head is a destructive disease that usually affects young adults with high functional demands and can have devastating effects on hip joint. The treatment depends on extent and location of the necrosis lesion and on patient's factors, that suggest disease progression, collapse probability and also implants survival. Non-idiopathic osteonecrosis patients had the worst outcome. There is not a gold standard treatment and frequently it is necessary a multidisciplinary approach. Preservation procedures of the femoral head are the first choice and can be attempted in younger patients without head collapse. Replacement procedure remains the main treatment after failure of preserving procedures and in the late-stage ONFH, involving collapse of the femoral head and degenerative changes to the acetabulum. Resurfacing procedure still has good results but the patient selection is a critical factor. Total hip arthroplasties had historically poor results in patients with osteonecrosis. More recently, reports have shown excellent results, but implant longevity and following revisions are still outstanding problems.

  1. Radiographic features of teriparatide-induced healing of femoral fractures

    Directory of Open Access Journals (Sweden)

    Youngwoo Kim

    2015-12-01

    Full Text Available Teriparatide is a drug that is used to increase bone remodeling, formation, and density for the treatment of osteoporosis. We present three cases of patients with a femoral insufficiency fracture. The patients were administered teripatatide in an attempt to treat severe osteoporosis and to enhance fracture healing. We found several radiographic features around the femoral fractures during the healing period. 1 Callus formation was found at a very early stage in the treatment. Teriparatide substantially increased the unusually abundant callus formation around the fracture site at 2 weeks. Moreover, this callus formation continued for 8 weeks and led to healing of the fracture. 2 Abundant callus formation was found circumferentially around the cortex with a ‘cloud-like’ appearance. 3 Remodeling of the teriparatide-induced callus formation was found to be part of the normal fracture healing process. After 1 year, normal remodeling was observed on plain radiographs. These findings indicate that teriparatide can be used as an adjuvant therapy in the management of femoral insufficiency fractures.

  2. Custom Knee Device for Knee Contractures After Internal Femoral Lengthening.

    Science.gov (United States)

    Bhave, Anil; Shabtai, Lior; Ong, Peck-Hoon; Standard, Shawn C; Paley, Dror; Herzenberg, John E

    2015-07-01

    The development of knee flexion contractures is among the most common problems and complications associated with lengthening the femur with an internal device or external fixator. Conservative treatment strategies include physical therapy, serial casting, and low-load prolonged stretching with commercially available splinting systems. The authors developed an individually molded, low-cost custom knee device with polyester synthetic conformable casting material to treat knee flexion contractures. The goal of this study was to evaluate the results of treatment with a custom knee device and specialized physical therapy in patients who had knee flexion contracture during femoral lengthening with an intramedullary lengthening femoral nail. This retrospective study included 23 patients (27 limbs) who underwent femoral lengthening with an internal device for the treatment of limb length discrepancy. All patients had a knee flexion contracture raging from 10° to 90° during the lengthening process and were treated with a custom knee device and specialized physical therapy. The average flexion contracture before treatment was 36°. The mean amount of lengthening was 5.4 cm. After an average of 3.8 weeks of use of the custom knee device, only 2 of 27 limbs (7.5%) had not achieved complete resolution of the flexion contracture. The average final extension was 1.4°. Only 7 of 27 limbs (26%) required additional soft tissue release. The custom knee device is an inexpensive and effective method for treating knee flexion contracture after lengthening with an internal device.

  3. Subtrochanteric Femoral Insufficiency Fracture Following Bisphosphonate Therapy for Osseous Metastases.

    Science.gov (United States)

    Bush, Lisabeth A; Chew, Felix S

    2008-01-01

    We present the case of an insufficiency fracture of the femoral shaft in a 61-year-old man who had received bisphosphonate therapy to reduce the fracture risk from lytic renal cell carcinoma metastases to the spine. Approximately 1.5 years after beginning monthly intravenous infusions of zoledronic acid (Zometa), the patient complained of persistent thigh pain. Radionuclide bone scan showed mildly increased activity in the lateral subtrochanteric cortex of the right femur, where there was focally increased T2 signal on MRI and a small, triangular ridge or cortical beak on radiographs. The lesion was initially thought to represent a metastasis, but after the patient returned with a transverse femoral shaft fracture through the ridge following minimal trauma, MRI and biopsy of the lesion failed to show any evidence of tumor. We suggest that this fracture is similar to the low-energy proximal femoral shaft fractures recently reported in postmenopausal women who have received oral bisphosphonates for osteoporosis. Suppression of bone turnover may play a role in the development of these fractures.

  4. Developing a sensation information message for femoral arteriography.

    Science.gov (United States)

    Clark, C R; Gregor, F M

    1988-03-01

    Sensation information is proposed as a way of decreasing the patient's distress during a threatening health care event. A first step in developing a sensation information message is to determine the content of the message. This study, using a systematic theory-based methodology, was conducted to describe and validate the common physical sensations experienced by patients undergoing the diagnostic procedure of femoral arteriography. (A conceptual framework based on how an individual perceives or senses a situation was used.) A three-stage survey design was used including: (1) tool development following observation of the procedure and pilot-testing of the interview schedule, (2) interview of patients who had undergone femoral arteriography about the sensations experienced during the procedure, and (3) validation of the responses. Twenty-one steps in the femoral arteriography procedure of which patients were aware were identified. Nine 'feeling' sensations commonly experienced during the procedure and the sights and sounds associated with the procedure were determined. The sequencing and duration of procedure steps were observed and the environment in which the procedure was performed was described.

  5. Unstable femoral neck fractures in children - A new treatment option

    Directory of Open Access Journals (Sweden)

    Pruthi K

    2006-01-01

    Full Text Available Background : Femoral neck fractures in children are an uncommon but difficult situation. The aim of our study was to evaluate clinical results of closed reduction internal fixation and primary valgus osteotomy fixed with a tension band wire loop in high angled pediatric femoral neck fractures. Methods : In a prospective nonrandomized study conducted at 2 centres, sixteen children and adolescents with a Pauwel type 2/3 fracture neck femur were taken as participants. The femoral neck fractures were stabilized using closed reduction and internal fixation (6.5 mm noncannulated screw and a primary valgus osteotomy fixed with a tension band wire loop preferably within 24-36 hours of injury. Patients were evaluated to determine complications, clinical and radiological outcome. Results : At a mean post operative follow up of 5 years, union was achieved in all cases. Three patients had AVN and one developed coxavara. Results were evaluated using IOWA hip scores. Thirteen patients had an excellent result while 3 patients had a good result. Conclusion : Use of this technique holds promise in treating these difficult unstable fractures. Although results from a larger series are still awaited yet the use of this technique can safely be extended to stable fractures also, to minimize the incidence of complications as nonunion and AVN.

  6. Calculation of pediatric femoral fracture rotation from direct roentgenograms.

    Science.gov (United States)

    Ozel, M S; Ketenci, I E; Kaya, E; Tuna, S; Saygi, B

    2013-12-01

    Radiologic determination of pediatric femoral fracture rotation has been debated. Measuring the antetorsion angle of the fractured femur by computed tomography and comparing it with the opposite side has been the method of choice for this purpose. However, no simple method for direct measurement of femoral fracture rotation exists in the literature. In this study, our aim was to test a mathematical method of measuring the axial plane malrotation from direct roentgenograms. A pediatric femoral shaft fracture model was produced. The bone was secured to a wooden frame that allowed the distal part of the fracture to rotate around an axis. Radiographs were taken at known intervals of rotation ranging from the neutral position to 60° external rotation and to 60° internal rotation in 5° increments of rotation. Five independent, blinded observers measured the radiographs and calculated the fracture rotation according to a standard formula. Calculated rotation values were compared with known rotation values. Calculated rotation values were close to actual rotation values throughout the arc of rotation. The mean absolute error of five observers for all measurements of external and internal rotation was 3.97° (±0.83). The correlation coefficient between calculated and actual rotation values was 0.9927. The interobserver intraclass correlation coefficient for calculated rotation was 0.997. Absolute error and correlation coefficient values indicate that this method is accurate and reliable in determining the fracture rotation.

  7. The surgical treatment of ilio-femoral venous obstruction.

    Science.gov (United States)

    Illuminati, G; Caliò, F G; D'Urso, A; Mancini, P; Papaspyropoulos, V; Ceccanei, G; Lorusso, R; Vietri, F

    2004-01-01

    A series of 9 patients of a mean age of 48 years, operated on for compression of the ilio-femoral venous axis is reported. The cause of obstruction was external compression in 3 cases, a retroperitoneal sarcoma in 1 case, and an infrarenal aortic aneurysm in 2. Two patients presented with a Cockett's syndrome, 3 with a chronic ilio-femoral thrombosis, and one with a post-traumatic segmentary stenosis. Treatment consisted in a resection/Dacron grafting of 2 infrarenal aortic aneurysms, one femoro-caval bypass graft, 2 transpositions of the right common iliac artery in the left hypogastric artery for Cockett's syndrome, 3 Palma's operations for chronic thrombosis, and one internal jugular vein interposition for segmentary stenosis. There were no postoperative deaths and no early thromboses of venous reconstructions performed. All the patients were relieved of symptoms during the follow-up period, whose mean length was 38 months. The cause of venous obstruction and the presence of symptoms which are resistant to medical treatment are the main indications to ilio-femoral venous revascularization. The choice of the optimal treatment in each single case yields satisfactory results.

  8. A Case of Bilateral Aseptic Necrosis of the Femoral Head

    Science.gov (United States)

    KAMAL, DIANA; TRĂISTARU, RODICA; KAMAL, C.K.; ALEXANDRU, D.O.; MOGOANTĂ, L.; GRECU, D.C.

    2014-01-01

    Aseptic necrosis of the femoral head is a disease whose etiology is not completely elucidated and generally affects young adults aged between 30 and 50 years. In a significant number of patients bilateral disease occurs, which makes detection in its early stages constitute an important objective. We present the case of a male patient, aged 23 years, with the following risk factors: smoking and chronic alcohol consumption, who is diagnosed with aseptic necrosis of the left femoral head, ARCO stage IV, and in just six months after the diagnosis and hip arthroplasty, he suffers an injury which leads to the same diagnosis in the contralateral hip. We want to emphasize that for all patients with a high index of suspicion there should be an MRI examination, because the plane radiographs or CT are most often not relevant in detecting early signs of this condition. Diagnosis of aseptic necrosis of the femoral head in the early stages is a necessity in order to obtain an optimal result of conservative treatment. PMID:26788359

  9. A Case of Bilateral Aseptic Necrosis of the Femoral Head.

    Science.gov (United States)

    Kamal, Diana; Trăistaru, Rodica; Kamal, C K; Alexandru, D O; Mogoantă, L; Grecu, D C

    2014-01-01

    Aseptic necrosis of the femoral head is a disease whose etiology is not completely elucidated and generally affects young adults aged between 30 and 50 years. In a significant number of patients bilateral disease occurs, which makes detection in its early stages constitute an important objective. We present the case of a male patient, aged 23 years, with the following risk factors: smoking and chronic alcohol consumption, who is diagnosed with aseptic necrosis of the left femoral head, ARCO stage IV, and in just six months after the diagnosis and hip arthroplasty, he suffers an injury which leads to the same diagnosis in the contralateral hip. We want to emphasize that for all patients with a high index of suspicion there should be an MRI examination, because the plane radiographs or CT are most often not relevant in detecting early signs of this condition. Diagnosis of aseptic necrosis of the femoral head in the early stages is a necessity in order to obtain an optimal result of conservative treatment.

  10. Magnetic Resonance Imaging of the Femoral Neck Cortex

    Energy Technology Data Exchange (ETDEWEB)

    Sievaenen, H.; Karstila, T.; Apuli, P.; Kannus, P. [Bone Research Group, UKK Inst., Tampere (Finland)

    2007-04-15

    Purpose: To determine the in vivo precision and accuracy of magnetic resonance imaging (MRI) in evaluating the thin (emm) femoral neck cortex. Material and Methods: Hip regions of 30 volunteers were scanned with standard 1.5T MRI twice with repositioning, and the images of the narrow-neck cross-sections were obtained. Two radiologists independently delineated periosteal and endosteal cortical boundaries, and several structural variables were determined. For precision, 95% limits of agreement and coefficients of variation were calculated. Accuracy was determined with phantoms. Results: In vivo precision of the directly delineated measurements varied from 0.9% (periosteal circumference) to 1.6% (total area), while the precision of the calculated variables remained poorer, from 7.3% (cortical to total area ratio) to 15.1% (torsional rigidity). The root-mean-square error of the cortical thickness measurement was 0.15 mm. Conclusion: Thin cortical bone at the narrowest location of the femoral neck can be delineated precisely and accurately with a standard clinical 1.5T MRI device. MRI provides a feasible tool for the assessment of mechanically important cortical bone at the femoral neck and may be of clinical utility in assessing hip fragility. Keywords Bone densitometry, bone fragility, bone strength, osteoporosis, precision.

  11. Evaluation of the Superior Gluteal Nerve During Proximal Femoral Nailing

    Directory of Open Access Journals (Sweden)

    Mehmet Sonmez

    2017-05-01

    Full Text Available Aim: The superior gluteal nerve may be compromised during hip surgery. We retrospectively evaluated the patients who underwent proximal femoral nailing for unstable trochanteric fractures in order to investigate the presence of superior gluteal nerve injury and its clinical findings. Material and Method: Twenty five patients (14 women, 11 men were included in the study who had femoral nailing between January 2004 and March 2010 at Hamidiye Sisli Etfal Training and Research Hospital Department of Orthopaedics. Two different types of nails which have similar designs and surgical techniques were used for fracture fixation. Patients who had a history of cerebrovascular disease, electromyography findings of polyneuropathy, or degenerative vertebral disease were excluded from the study. Patients were evaluated clinically and radiologically. Findings related to acute denervation in the gluteus medius muscle and motor unit action potential changes were accepted as signs of superior gluteal nerve injury. Results: Eight patients were using support during walking and three of these patients had positive Trendelenburg sign, but only one patient had acute denervation signs of the superior gluteal nerve. Discussion: Based on the present study the incidence of iatrogenic nerve injury is a rare complication of proximal femoral nailing. Elderly patients, regardless of whether they have nerve injury, may limp and need to use a walking support.

  12. Varus distal femoral osteotomy in young adults with valgus knee

    Directory of Open Access Journals (Sweden)

    Mazlumi Mahdi

    2009-05-01

    Full Text Available Abstract Background Musculoskeletal disorders specially knee osteoarthritis are the most common causes of morbidity in old patients. Disturbance of the mechanical axis of the lower extremity is one of the most important causes in progression of knee osteoarthritis. The purpose of the present study was to analyze the surgical results of distal femoral varus osteotomy in patients with genu valgum. Methods In this study, after recording history and physical examination, appropriate radiographs were taken. We did varus distal femoral osteotomy by standard medial subvastus approach and 90-angle blade plate fixation then followed the patients clinically and radiographically. Results This study was done on 23 knees (16 patients age 23.3 years (range, 17 to 41 years. The mean duration of following up was 16.3 months (range, 8 to 25 months. Based on paired T test, there were statistically significant difference between pre- and postoperative tibiofemoral and congruence angles (p Conclusion Distal femoral varus osteotomy with blade plate fixation can be a reliable procedure for the treatment of valgus knee deformity. In this procedure, with more tibiofemoral angle correction, more congruence angle correction can be achieved. Therefore, along with genu valgum correction, the patella should be stabilized simultaneously.

  13. [Femoral venous catheterization. Does it really need to be avoided?].

    Science.gov (United States)

    Lorente, L; León, C

    2009-12-01

    The guidelines to prevent central venous catheter related bloodstream infections (CVCBSI) of the Centers for Disease Control and Prevention (CDC) of 2002, Sociedad Española de Medicina Intensiva, Crítica y Unidades Coronarias/ Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEMICYUC/SEIMC) of 2004, and the recently published guidelines of the Society for Healthcare Epidemiology of America/Infectious Diseases Society of America (SHEA(IDSA) of 2008 have recommended using the subclavian vein and avoiding the use of the femoral vein. They also recommend considering the use of antiseptic- or antimicrobial-impregnated CVCs for hospital units or groups of patients with a high incidence of CVCBSI. When implementing these guidelines, two questions could be asked: 1) Could the abuse of the subclavian vein and avoiding the use of the femoral vein imply a decrease in the incidence of CVCBSI, but an increase in the rate of mechanical complications as pneumothorax and/or hemothorax? 2) Couldn't antimicrobial-impregnated CVCs be used to prevent CVCBSI when the femoral venous access is used?

  14. Osteonecrosis of the femoral head after bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Mi; Jun, Jeong Su; Park, Chang Suk; Kim, Yong Sik; Kwon, Soon Yong; Kim, Yoo Jin; Kim, Chun Choo [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2003-07-01

    To retrospectively review findings of osteonecrosis of the femoral head after bone marrow transplantation. We reviewed the clinical and MR findings of osteonecrosis of the femoral head in 23 of 1112 patients who underwent marrow transplantation during a five-year follow-up period lasting from 1996 to 2000. Mean age at the time of diagnosis was 31 (range, 20-47) years, and the mean time from transplant to diagnosis was 17 months. All patients developed variable graft-versus-host disease and seventeen were treated with high-dose prednisolone and/or cysclosporin for severe acute or extensive chronic graft versus host disease. Osteonecrosis was diagnosed by magnetic resonance (MR) imaging, which allowed early detection of disease assessment of its stage. At the time of diagnosis, 15 hips were at stage I, 28 at stage II, two at stage III, and none at stage IV, according to the international ARCO classification system. Osteonecrosis of femoral diaphyses, the lower lumbar spine, or pelvic bones in the MR field was also found to have occurred in 11 patients. Initial treatment was conservative: 21 hips underwent surgery [core decompression (n=10), vascularized fibular bone graft (n=5), and joint replacement (n=6)]. In patients receiving high-dose steroids for the treatment of graft-versus-host disease, MR screening might help detect osteonecrosis at an early stage.

  15. Strangulated Femoral Hernia Turned to Be Peritoneal Cyst

    Directory of Open Access Journals (Sweden)

    Dionysios Dellaportas

    2012-01-01

    Full Text Available Introduction. A peritoneal inclusion cyst is a very rare mesenteric cyst of mesothelial origin usually asymptomatic. A rare case of an 82-year-old white Caucasian female with a femoral hernia containing a large peritoneal inclusion cyst, mimicking strangulated hernia, is presented herein. Case Presentation. The patient was admitted to our hospital suffering from a palpable groin mass on the right, which became painful and caused great discomfort for the last hours. Physical examination revealed a tender and tense, irreducible groin mass. An inguinal operative approach was selected and the mass was found protruding through the femoral ring. After careful dissection it turned out to be a large unilocular cyst, containing serous fluid, probably originating from the peritoneum. McVay procedure was used to reapproximate the femoral ring. Histologic examination showed a peritoneal inclusion cyst. Discussion. Peritoneal inclusion cysts are usually asymptomatic but occasionally present with various, nonspecific symptoms according to their size. Our case highlights that high index of clinical suspicion and careful exploration during repair of a hernia is mandatory in order to reach the correct diagnosis about hernia’s contents.

  16. Distal femoral extension osteotomy and patellar tendon advancement to treat persistent crouch gait in cerebral palsy. Surgical technique.

    Science.gov (United States)

    Novacheck, Tom F; Stout, Jean L; Gage, James R; Schwartz, Michael H

    2009-10-01

    Hallmarks of a persistent crouched walking pattern exhibited by individuals with cerebral palsy usually include loss of an adequate plantar flexion/knee extension couple, hamstring and/or psoas tightness, or contracture in conjunction with quadriceps insufficiency. Traditional treatment addresses the muscle-tightness component, but not the contracture or the muscle insufficiency. This study was performed to evaluate the effectiveness of distal femoral extension osteotomy and/or patellar tendon advancement in the treatment of crouch gait in patients with cerebral palsy. A retrospective, nonrandomized, repeated-measures design was used. Individuals with a diagnosis of cerebral palsy were included if they had had (1) a distal femoral extension osteotomy in combination with a distal patellar tendon advancement (thirty-three patients), (2) a distal femoral extension osteotomy without patellar tendon advancement (sixteen), or (3) a distal patellar tendon advancement only (twenty-four). All subjects were evaluated with preoperative and postoperative gait analysis. Gait, radiographic, strength, and functional measures were included in the analysis to assess changes in knee function. Seventy-three individuals met the criteria for inclusion. A single side was chosen for the analysis of each subject. Ninety percent of the subjects had additional, concurrent surgery. Improvements were noted in the index assessing the level of gait pathology and in functional variables across all groups, and pain was consistently decreased. All preoperative stress fractures healed. Strength levels were maintained across all groups. The Koshino index of patellar height improved from 1.4 to -2.3 in the group treated with patellar tendon advancement only and from 1.5 to -2.9 in the group treated with both osteotomy and tendon advancement. The range of knee flexion improved an average of 15 degrees to 20 degrees , and stance-phase knee flexion was restored to the typical range (9 degrees to 10

  17. Multiple Small Diameter Drillings Increase Femoral Neck Stability Compared with Single Large Diameter Femoral Head Core Decompression Technique for Avascular Necrosis of the Femoral Head.

    Science.gov (United States)

    Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E

    2016-10-26

    Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (pcore decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.

  18. Diagnostic methods in ischemic necrosis of the femoral head. Metodos de diagnostico en la necrosis isquemica de la cabeza femoral

    Energy Technology Data Exchange (ETDEWEB)

    Parra Blanco, J.A.; Pagola Serrano, M.A.; Delgado Macias, M.T. (Hospital Universitario Marques de Valdecilla, Santander (Spain))

    1994-01-01

    Ischemic necrosis of the femoral head (INFH) must be diagnosed at an early stage of development, when therapeutic approaches such as forage biopsy or osteotomy can prevent or slow the normal progression of the disease to arthrosis. In this article, on the basis of the pathological changes that characterize process, we review the advantages and limitations of the principal diagnostic techniques (table I) currently employed in the study of INFH. (Author)

  19. MR evaluation of the articular cartilage of the femoral head during traction. Correlation with resected femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, K. [Osaka Seamens Insurance Hospital (Japan). Dept. of Radiology; Tanaka, H.; Narumi, Y.; Nakamura, H. [Osaka Univ. Medical School (Japan). Dept. of Radiology; Nishii, T.; Masuhara, K. [Osaka Univ. Medical School (Japan). Dept. of Orthopedic Surgery

    1999-01-01

    Objective: The purpose was to evaluate the articular cartilage of the hip joint with MR during traction and compare the findings with the resected specimen or arthroscopic findings. Material and Methods: Eight healthy volunteers, 5 patients with osteonecrosis, 5 with acetabular dysplasia, and 5 with advanced osteoarthrosis underwent MR imaging to evaluate the articular cartilage of the hip joint. Coronal fat-suppressed 3D spoiled gradient-echo (SPGR) images were obtained during traction. Identical imaging was performed of all the resected femoral heads of the osteonecrosis and advanced osteoarthrosis patients, and was correlated with the macroscopic pathological findings. Results: The traction was effective and the femoral articular cartilage was clearly identified in all 8 control subjects, and in all cases of osteonecrosis and acetabular dysplasia. In 4 cases of osteonecrosis, chondral fracture was identified in the boundary between the necrosis and the normal area. In all cases of advanced osteoarthrosis, cartilage was identified only at the medial side. The MR images of osteonecrosis and advanced osteoarthrosis corresponded well with the MR images of the resected femoral heads and the macroscopic findings. (orig.)

  20. Reoperation Rates for Laparoscopic vs Open Repair of Femoral Hernias in Denmark

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Bisgaard, Thue; Kehlet, Henrik

    2014-01-01

    IMPORTANCE: In Denmark approximately 10 000 groin hernias are repaired annually, of which 2% to 4% are femoral hernias. Several methods for repair of femoral hernias are used including sutured repair and different types of mesh repair with either open or laparoscopic techniques. The use of many...... laparoscopic vs open femoral hernia repair, analyzing data from a nationwide database. DESIGN, SETTING, AND PARTICIPANTS: A prospective cohort study was conducted. Data on femoral hernia repairs registered in the Danish Hernia Database from January 1998 until February 2012 were extracted and analyzed. All...... repairs were followed in the database and analyzed for reports of reoperation, which were used as a proxy for recurrence. Femoral hernia recurrence and inguinal hernia occurrence after the index repair were analyzed. EXPOSURE: Repair of a femoral hernia. MAIN OUTCOMES AND MEASURES: Reoperation...