WorldWideScience

Sample records for fault tree conditioning

  1. Fault trees for diagnosis of system fault conditions

    International Nuclear Information System (INIS)

    Lambert, H.E.; Yadigaroglu, G.

    1977-01-01

    Methods for generating repair checklists on the basis of fault tree logic and probabilistic importance are presented. A one-step-ahead optimization procedure, based on the concept of component criticality, minimizing the expected time to diagnose system failure is outlined. Options available to the operator of a nuclear power plant when system fault conditions occur are addressed. A low-pressure emergency core cooling injection system, a standby safeguard system of a pressurized water reactor power plant, is chosen as an example illustrating the methods presented

  2. Fault tree handbook

    International Nuclear Information System (INIS)

    Haasl, D.F.; Roberts, N.H.; Vesely, W.E.; Goldberg, F.F.

    1981-01-01

    This handbook describes a methodology for reliability analysis of complex systems such as those which comprise the engineered safety features of nuclear power generating stations. After an initial overview of the available system analysis approaches, the handbook focuses on a description of the deductive method known as fault tree analysis. The following aspects of fault tree analysis are covered: basic concepts for fault tree analysis; basic elements of a fault tree; fault tree construction; probability, statistics, and Boolean algebra for the fault tree analyst; qualitative and quantitative fault tree evaluation techniques; and computer codes for fault tree evaluation. Also discussed are several example problems illustrating the basic concepts of fault tree construction and evaluation

  3. Two Trees: Migrating Fault Trees to Decision Trees for Real Time Fault Detection on International Space Station

    Science.gov (United States)

    Lee, Charles; Alena, Richard L.; Robinson, Peter

    2004-01-01

    We started from ISS fault trees example to migrate to decision trees, presented a method to convert fault trees to decision trees. The method shows that the visualizations of root cause of fault are easier and the tree manipulating becomes more programmatic via available decision tree programs. The visualization of decision trees for the diagnostic shows a format of straight forward and easy understands. For ISS real time fault diagnostic, the status of the systems could be shown by mining the signals through the trees and see where it stops at. The other advantage to use decision trees is that the trees can learn the fault patterns and predict the future fault from the historic data. The learning is not only on the static data sets but also can be online, through accumulating the real time data sets, the decision trees can gain and store faults patterns in the trees and recognize them when they come.

  4. Condition-based fault tree analysis (CBFTA): A new method for improved fault tree analysis (FTA), reliability and safety calculations

    International Nuclear Information System (INIS)

    Shalev, Dan M.; Tiran, Joseph

    2007-01-01

    Condition-based maintenance methods have changed systems reliability in general and individual systems in particular. Yet, this change does not affect system reliability analysis. System fault tree analysis (FTA) is performed during the design phase. It uses components failure rates derived from available sources as handbooks, etc. Condition-based fault tree analysis (CBFTA) starts with the known FTA. Condition monitoring (CM) methods applied to systems (e.g. vibration analysis, oil analysis, electric current analysis, bearing CM, electric motor CM, and so forth) are used to determine updated failure rate values of sensitive components. The CBFTA method accepts updated failure rates and applies them to the FTA. The CBFTA recalculates periodically the top event (TE) failure rate (λ TE ) thus determining the probability of system failure and the probability of successful system operation-i.e. the system's reliability. FTA is a tool for enhancing system reliability during the design stages. But, it has disadvantages, mainly it does not relate to a specific system undergoing maintenance. CBFTA is tool for updating reliability values of a specific system and for calculating the residual life according to the system's monitored conditions. Using CBFTA, the original FTA is ameliorated to a practical tool for use during the system's field life phase, not just during system design phase. This paper describes the CBFTA method and its advantages are demonstrated by an example

  5. Summary: beyond fault trees to fault graphs

    International Nuclear Information System (INIS)

    Alesso, H.P.; Prassinos, P.; Smith, C.F.

    1984-09-01

    Fault Graphs are the natural evolutionary step over a traditional fault-tree model. A Fault Graph is a failure-oriented directed graph with logic connectives that allows cycles. We intentionally construct the Fault Graph to trace the piping and instrumentation drawing (P and ID) of the system, but with logical AND and OR conditions added. Then we evaluate the Fault Graph with computer codes based on graph-theoretic methods. Fault Graph computer codes are based on graph concepts, such as path set (a set of nodes traveled on a path from one node to another) and reachability (the complete set of all possible paths between any two nodes). These codes are used to find the cut-sets (any minimal set of component failures that will fail the system) and to evaluate the system reliability

  6. Introduction to fault tree analysis

    International Nuclear Information System (INIS)

    Barlow, R.E.; Lambert, H.E.

    1975-01-01

    An elementary, engineering oriented introduction to fault tree analysis is presented. The basic concepts, techniques and applications of fault tree analysis, FTA, are described. The two major steps of FTA are identified as (1) the construction of the fault tree and (2) its evaluation. The evaluation of the fault tree can be qualitative or quantitative depending upon the scope, extensiveness and use of the analysis. The advantages, limitations and usefulness of FTA are discussed

  7. Fault tree graphics

    International Nuclear Information System (INIS)

    Bass, L.; Wynholds, H.W.; Porterfield, W.R.

    1975-01-01

    Described is an operational system that enables the user, through an intelligent graphics terminal, to construct, modify, analyze, and store fault trees. With this system, complex engineering designs can be analyzed. This paper discusses the system and its capabilities. Included is a brief discussion of fault tree analysis, which represents an aspect of reliability and safety modeling

  8. Computer-oriented approach to fault-tree construction

    International Nuclear Information System (INIS)

    Salem, S.L.; Apostolakis, G.E.; Okrent, D.

    1976-11-01

    A methodology for systematically constructing fault trees for general complex systems is developed and applied, via the Computer Automated Tree (CAT) program, to several systems. A means of representing component behavior by decision tables is presented. The method developed allows the modeling of components with various combinations of electrical, fluid and mechanical inputs and outputs. Each component can have multiple internal failure mechanisms which combine with the states of the inputs to produce the appropriate output states. The generality of this approach allows not only the modeling of hardware, but human actions and interactions as well. A procedure for constructing and editing fault trees, either manually or by computer, is described. The techniques employed result in a complete fault tree, in standard form, suitable for analysis by current computer codes. Methods of describing the system, defining boundary conditions and specifying complex TOP events are developed in order to set up the initial configuration for which the fault tree is to be constructed. The approach used allows rapid modifications of the decision tables and systems to facilitate the analysis and comparison of various refinements and changes in the system configuration and component modeling

  9. Computer aided construction of fault tree

    International Nuclear Information System (INIS)

    Kovacs, Z.

    1982-01-01

    Computer code CAT for the automatic construction of the fault tree is briefly described. Code CAT makes possible simple modelling of components using decision tables, it accelerates the fault tree construction process, constructs fault trees of different complexity, and is capable of harmonized co-operation with programs PREPandKITT 1,2 for fault tree analysis. The efficiency of program CAT and thus the accuracy and completeness of fault trees constructed significantly depends on the compilation and sophistication of decision tables. Currently, program CAT is used in co-operation with programs PREPandKITT 1,2 in reliability analyses of nuclear power plant systems. (B.S.)

  10. Integrating cyber attacks within fault trees

    International Nuclear Information System (INIS)

    Nai Fovino, Igor; Masera, Marcelo; De Cian, Alessio

    2009-01-01

    In this paper, a new method for quantitative security risk assessment of complex systems is presented, combining fault-tree analysis, traditionally used in reliability analysis, with the recently introduced Attack-tree analysis, proposed for the study of malicious attack patterns. The combined use of fault trees and attack trees helps the analyst to effectively face the security challenges posed by the introduction of modern ICT technologies in the control systems of critical infrastructures. The proposed approach allows considering the interaction of malicious deliberate acts with random failures. Formal definitions of fault tree and attack tree are provided and a mathematical model for the calculation of system fault probabilities is presented.

  11. Integrating cyber attacks within fault trees

    Energy Technology Data Exchange (ETDEWEB)

    Nai Fovino, Igor [Joint Research Centre - EC, Institute for the Protection and Security of the Citizen, Ispra, VA (Italy)], E-mail: igor.nai@jrc.it; Masera, Marcelo [Joint Research Centre - EC, Institute for the Protection and Security of the Citizen, Ispra, VA (Italy); De Cian, Alessio [Department of Electrical Engineering, University di Genova, Genoa (Italy)

    2009-09-15

    In this paper, a new method for quantitative security risk assessment of complex systems is presented, combining fault-tree analysis, traditionally used in reliability analysis, with the recently introduced Attack-tree analysis, proposed for the study of malicious attack patterns. The combined use of fault trees and attack trees helps the analyst to effectively face the security challenges posed by the introduction of modern ICT technologies in the control systems of critical infrastructures. The proposed approach allows considering the interaction of malicious deliberate acts with random failures. Formal definitions of fault tree and attack tree are provided and a mathematical model for the calculation of system fault probabilities is presented.

  12. Fault tree analysis

    International Nuclear Information System (INIS)

    1981-09-01

    Suggestion are made concerning the method of the fault tree analysis, the use of certain symbols in the examination of system failures. This purpose of the fault free analysis is to find logical connections of component or subsystem failures leading to undesirable occurrances. The results of these examinations are part of the system assessment concerning operation and safety. The objectives of the analysis are: systematical identification of all possible failure combinations (causes) leading to a specific undesirable occurrance, finding of reliability parameters such as frequency of failure combinations, frequency of the undesirable occurrance or non-availability of the system when required. The fault tree analysis provides a near and reconstructable documentation of the examination. (orig./HP) [de

  13. FAULT TREE ANALYSIS FOR EXPOSURE TO REFRIGERANTS USED FOR AUTOMOTIVE AIR CONDITIONING IN THE U.S.

    Science.gov (United States)

    A fault tree analysis was used to estimate the number of refrigerant exposures of automotive service technicians and vehicle occupants in the United States. Exposures of service technicians can occur when service equipment or automotive air-conditioning systems leak during servic...

  14. Fault tree analysis. Implementation of the WAM-codes

    International Nuclear Information System (INIS)

    Bento, J.P.; Poern, K.

    1979-07-01

    The report describes work going on at Studsvik at the implementation of the WAM code package for fault tree analysis. These codes originally developed under EPRI contract by Sciences Applications Inc, allow, in contrast with other fault tree codes, all Boolean operations, thus allowing modeling of ''NOT'' conditions and dependent components. To concretize the implementation of these codes, the auxiliary feed-water system of the Swedish BWR Oskarshamn 2 was chosen for the reliability analysis. For this system, both the mean unavailability and the probability density function of the top event - undesired event - of the system fault tree were calculated, the latter using a Monte-Carlo simulation technique. The present study is the first part of a work performed under contract with the Swedish Nuclear Power Inspectorate. (author)

  15. TREDRA, Minimal Cut Sets Fault Tree Plot Program

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1983-01-01

    1 - Description of problem or function: TREDRA is a computer program for drafting report-quality fault trees. The input to TREDRA is similar to input for standard computer programs that find minimal cut sets from fault trees. Output includes fault tree plots containing all standard fault tree logic and event symbols, gate and event labels, and an output description for each event in the fault tree. TREDRA contains the following features: a variety of program options that allow flexibility in the program output; capability for automatic pagination of the output fault tree, when necessary; input groups which allow labeling of gates, events, and their output descriptions; a symbol library which includes standard fault tree symbols plus several less frequently used symbols; user control of character size and overall plot size; and extensive input error checking and diagnostic oriented output. 2 - Method of solution: Fault trees are generated by user-supplied control parameters and a coded description of the fault tree structure consisting of the name of each gate, the gate type, the number of inputs to the gate, and the names of these inputs. 3 - Restrictions on the complexity of the problem: TREDRA can produce fault trees with a minimum of 3 and a maximum of 56 levels. The width of each level may range from 3 to 37. A total of 50 transfers is allowed during pagination

  16. Modular representation and analysis of fault trees

    Energy Technology Data Exchange (ETDEWEB)

    Olmos, J; Wolf, L [Massachusetts Inst. of Tech., Cambridge (USA). Dept. of Nuclear Engineering

    1978-08-01

    An analytical method to describe fault tree diagrams in terms of their modular compositions is developed. Fault tree structures are characterized by recursively relating the top tree event to all its basic component inputs through a set of equations defining each of the modulus for the fault tree. It is shown that such a modular description is an extremely valuable tool for making a quantitative analysis of fault trees. The modularization methodology has been implemented into the PL-MOD computer code, written in PL/1 language, which is capable of modularizing fault trees containing replicated components and replicated modular gates. PL-MOD in addition can handle mutually exclusive inputs and explicit higher order symmetric (k-out-of-n) gates. The step-by-step modularization of fault trees performed by PL-MOD is demonstrated and it is shown how this procedure is only made possible through an extensive use of the list processing tools available in PL/1. A number of nuclear reactor safety system fault trees were analyzed. PL-MOD performed the modularization and evaluation of the modular occurrence probabilities and Vesely-Fussell importance measures for these systems very efficiently. In particular its execution time for the modularization of a PWR High Pressure Injection System reduced fault tree was 25 times faster than that necessary to generate its equivalent minimal cut-set description using MOCUS, a code considered to be fast by present standards.

  17. Computer-aided Fault Tree Analysis

    International Nuclear Information System (INIS)

    Willie, R.R.

    1978-08-01

    A computer-oriented methodology for deriving minimal cut and path set families associated with arbitrary fault trees is discussed first. Then the use of the Fault Tree Analysis Program (FTAP), an extensive FORTRAN computer package that implements the methodology is described. An input fault tree to FTAP may specify the system state as any logical function of subsystem or component state variables or complements of these variables. When fault tree logical relations involve complements of state variables, the analyst may instruct FTAP to produce a family of prime implicants, a generalization of the minimal cut set concept. FTAP can also identify certain subsystems associated with the tree as system modules and provide a collection of minimal cut set families that essentially expresses the state of the system as a function of these module state variables. Another FTAP feature allows a subfamily to be obtained when the family of minimal cut sets or prime implicants is too large to be found in its entirety; this subfamily consists only of sets that are interesting to the analyst in a special sense

  18. Users' manual for the FTDRAW (Fault Tree Draw) code

    International Nuclear Information System (INIS)

    Oikawa, Tetsukuni; Hikawa, Michihiro; Tanabe, Syuichi; Nakamura, Norihiro

    1985-02-01

    This report provides the information needed to use the FTDRAW (Fault Tree Draw) code, which is designed for drawing a fault tree. The FTDRAW code has several optional functions, such as the overview of a fault tree output, fault tree output in English description, fault tree output in Japanese description and summary tree output. Inputs for the FTDRAW code are component failure rate information and gate information which are filed out by a execution of the FTA-J (Fault Tree Analysis-JAERI) code system and option control data. Using the FTDRAW code, we can get drawings of fault trees which is easy to see, efficiently. (author)

  19. Report on AECB consultative document C-70: The use of fault trees in licensing submissions

    International Nuclear Information System (INIS)

    1984-01-01

    The Atomic Energy Control Board (AECB) has issued Consultative Document C-70, 'The Use of Fault Trees in Licensing Submissions', for public comment. The Advisory Committee on Nuclear Safety (ACNS) has examined this document and ACNS members have met with AECB staff and representatives of the nuclear industry to discuss it. The ACNS presents its comments and recommendations in this report. The consultative document defines a fault tree as a hierarchically-structured graphical representation of system failures and their potential causes. The document then states certain basic characteristics or attributes which fault trees should possess, and certain conditions affecting the use of fault trees. It defines fault tree fundamentals, sets criteria for the application of fault trees to systems and defines ground rules for a fault tree format. Finally, in two appendices, it includes specific rules for fault tree symbols and fault tree description files for computer use. The appendices are referred to in the text as 'acceptable' standards or methods

  20. Cafts: computer aided fault tree analysis

    International Nuclear Information System (INIS)

    Poucet, A.

    1985-01-01

    The fault tree technique has become a standard tool for the analysis of safety and reliability of complex system. In spite of the costs, which may be high for a complete and detailed analysis of a complex plant, the fault tree technique is popular and its benefits are fully recognized. Due to this applications of these codes have mostly been restricted to simple academic examples and rarely concern complex, real world systems. In this paper an interactive approach to fault tree construction is presented. The aim is not to replace the analyst, but to offer him an intelligent tool which can assist him in modeling complex systems. Using the CAFTS-method, the analyst interactively constructs a fault tree in two phases: (1) In a first phase he generates an overall failure logic structure of the system; the macrofault tree. In this phase, CAFTS features an expert system approach to assist the analyst. It makes use of a knowledge base containing generic rules on the behavior of subsystems and components; (2) In a second phase the macrofault tree is further refined and transformed in a fully detailed and quantified fault tree. In this phase a library of plant-specific component failure models is used

  1. Software development to assist in fault tree construction

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1992-01-01

    This paper reviews and classifies fault tree construction methods developed for system safety and reliability. We have outlined two generally different approaches: automatic and interactive fault tree construction. Automatic fault tree approach is no jet enough developed to covering various uses in practice. Interactive approach is intending to be support to the analyst (not vice verse like in automatic approach). The aim is not so high as automatic one but it is accessible. We have favored interactive approach as well because to our opinion the process of fault tree construction is very important for better system understanding. We have described our example of interactive fault tree construction approach. Computer code GIFFT (Graphical Interactive Fault Tree Tool) is in phase of intensive testing and final developing. (author) [hr

  2. FTAP, Minimal Cut Sets of Arbitrary Fault Trees. FRTPLT, Fault Tree Structure and Logical Gates Plot for Program FTAP. FRTGEN, Fault Trees by Sub-tree Generator from Parent Tree for Program FTAP

    International Nuclear Information System (INIS)

    Willie, Randall R.; Rabien, U.

    1997-01-01

    1 - Description of problem or function: FTAP is a general-purpose program for deriving minimal reliability cut and path set families from the fault tree for a complex system. The program has a number of useful features that make it well-suited to nearly all fault tree applications. An input fault tree may specify the system state as any logical function of subsystem or component state variables or complements of these variables; thus, for instance, 'exclusive-or' type relations may be formed. When fault tree logical relations involve complements of state variables, the analyst may instruct FTAP to produce a family of prime implicants, a generalization of the minimal cut set concept. The program offers the flexibility of several distinct methods of generating cut set families. FTAP can also identify certain subsystems as system modules and provide a collection of minimal cut set families that essentially expresses the system state as a function of these module state variables. Another feature allows a useful subfamily to be obtained when the family of minimal cut sets or prime implicants is too large to be found in its entirety; this subfamily may consist of only those sets not containing more than some fixed number of elements or only those sets 'interesting' to the analyst in some special sense. Finally, the analyst can modify the input fault tree in various ways by declaring state variables identically true or false. 2 - Method of solution: Fault tree methods are based on the observation that the system state, either working or failed, can usually be expressed as a Boolean relation between states of several large, readily identifiable subsystems. The state of each subsystem in turn depends on states of simpler subsystems and components which compose it, so that the state of the system itself is determined by a hierarchy of logical relationships between states of subsystems. A fault tree is a graphical representation of these relationships. 3 - Restrictions on the

  3. Efficient fault tree handling - the Asea-Atom approach

    International Nuclear Information System (INIS)

    Ericsson, G.; Knochenhauer, M.; Mills, R.

    1985-01-01

    In recent years there has been a trend in Swedish Probabilistic Safety Analysis (PSA) work towards coordination of the tools and methods used, in order to facilitate exchange of information and review. Thus, standardized methods for fault tree drawing and basic event coding have been developed as well as a number of computer codes for fault tree handling. The computer code used by Asea-Atom is called SUPER-TREE. As indicated by the name, the key feature is the concept of one super tree containing all the information necessary in the fault tree analysis, i.e. system fault trees, sequence fault trees and component data base. The code has proved to allow great flexibility in the choice of level of detail in the analysis

  4. Integrated fault tree development environment

    International Nuclear Information System (INIS)

    Dixon, B.W.

    1986-01-01

    Probabilistic Risk Assessment (PRA) techniques are utilized in the nuclear industry to perform safety analyses of complex defense-in-depth systems. A major effort in PRA development is fault tree construction. The Integrated Fault Tree Environment (IFTREE) is an interactive, graphics-based tool for fault tree design. IFTREE provides integrated building, editing, and analysis features on a personal workstation. The design philosophy of IFTREE is presented, and the interface is described. IFTREE utilizes a unique rule-based solution algorithm founded in artificial intelligence (AI) techniques. The impact of the AI approach on the program design is stressed. IFTREE has been developed to handle the design and maintenance of full-size living PRAs and is currently in use

  5. Time-dependent methodology for fault tree evaluation

    International Nuclear Information System (INIS)

    Vesely, W.B.

    1976-01-01

    Any fault tree may be evaluated applying the method called the kinetic theory of fault trees. The basic feature of this method as presented here is in that any information on primary failure, type failure or peak failure is derived from three characteristics: probability of existence, failure intensity and failure density. The determination of the said three characteristics for a given phenomenon yields the remaining probabilistic information on the individual aspects of the failure and on their totality for the whole observed period. The probabilistic characteristics are determined by applying the analysis of phenomenon probability. The total time dependent information on the peak failure is obtained by using the type failures (critical paths) of the fault tree. By applying the said process the total time dependent information is obtained for every primary failure and type failure of the fault tree. In the application of the method of the kinetic theory of fault trees represented by the PREP and KITT programmes, the type failures are first obtained using the deterministic testing method or using the Monte Carlo simulation (PREP programme). The respective characteristics are then determined using the kinetic theory of fault trees (KITT programmes). (Oy)

  6. Advanced features of the fault tree solver FTREX

    International Nuclear Information System (INIS)

    Jung, Woo Sik; Han, Sang Hoon; Ha, Jae Joo

    2005-01-01

    This paper presents advanced features of a fault tree solver FTREX (Fault Tree Reliability Evaluation eXpert). Fault tree analysis is one of the most commonly used methods for the safety analysis of industrial systems especially for the probabilistic safety analysis (PSA) of nuclear power plants. Fault trees are solved by the classical Boolean algebra, conventional Binary Decision Diagram (BDD) algorithm, coherent BDD algorithm, and Bayesian networks. FTREX could optionally solve fault trees by the conventional BDD algorithm or the coherent BDD algorithm and could convert the fault trees into the form of the Bayesian networks. The algorithm based on the classical Boolean algebra solves a fault tree and generates MCSs. The conventional BDD algorithm generates a BDD structure of the top event and calculates the exact top event probability. The BDD structure is a factorized form of the prime implicants. The MCSs of the top event could be extracted by reducing the prime implicants in the BDD structure. The coherent BDD algorithm is developed to overcome the shortcomings of the conventional BDD algorithm such as the huge memory requirements and a long run time

  7. Study on reliability analysis based on multilevel flow models and fault tree method

    International Nuclear Information System (INIS)

    Chen Qiang; Yang Ming

    2014-01-01

    Multilevel flow models (MFM) and fault tree method describe the system knowledge in different forms, so the two methods express an equivalent logic of the system reliability under the same boundary conditions and assumptions. Based on this and combined with the characteristics of MFM, a method mapping MFM to fault tree was put forward, thus providing a way to establish fault tree rapidly and realizing qualitative reliability analysis based on MFM. Taking the safety injection system of pressurized water reactor nuclear power plant as an example, its MFM was established and its reliability was analyzed qualitatively. The analysis result shows that the logic of mapping MFM to fault tree is correct. The MFM is easily understood, created and modified. Compared with the traditional fault tree analysis, the workload is greatly reduced and the modeling time is saved. (authors)

  8. Fault diagnostics of dynamic system operation using a fault tree based method

    International Nuclear Information System (INIS)

    Hurdle, E.E.; Bartlett, L.M.; Andrews, J.D.

    2009-01-01

    For conventional systems, their availability can be considerably improved by reducing the time taken to restore the system to the working state when faults occur. Fault identification can be a significant proportion of the time taken in the repair process. Having diagnosed the problem the restoration of the system back to its fully functioning condition can then take place. This paper expands the capability of previous approaches to fault detection and identification using fault trees for application to dynamically changing systems. The technique has two phases. The first phase is modelling and preparation carried out offline. This gathers information on the effects that sub-system failure will have on the system performance. Causes of the sub-system failures are developed in the form of fault trees. The second phase is application. Sensors are installed on the system to provide information about current system performance from which the potential causes can be deduced. A simple system example is used to demonstrate the features of the method. To illustrate the potential for the method to deal with additional system complexity and redundancy, a section from an aircraft fuel system is used. A discussion of the results is provided.

  9. Computer aided fault tree construction for electrical systems

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1975-01-01

    A technique is presented for automated construction of the Boolean failure logic diagram, called the fault tree, for electrical systems. The method is a technique for synthesizing a fault tree from system-independent component characteristics. Terminology is defined and heuristic examples are given for all phases of the model. The computer constructed fault trees are in conventional format, use conventional symbols, and are deductively constructed from the main failure of interest to the individual component failures. The synthesis technique is generally applicable to automated fault tree construction for other types of systems

  10. Failure diagnosis and fault tree analysis

    International Nuclear Information System (INIS)

    Weber, G.

    1982-07-01

    In this report a methodology of failure diagnosis for complex systems is presented. Systems which can be represented by fault trees are considered. This methodology is based on switching algebra, failure diagnosis of digital circuits and fault tree analysis. Relations between these disciplines are shown. These relations are due to Boolean algebra and Boolean functions used throughout. It will be shown on this basis that techniques of failure diagnosis and fault tree analysis are useful to solve the following problems: 1. describe an efficient search of all failed components if the system is failed. 2. Describe an efficient search of all states which are close to a system failure if the system is still operating. The first technique will improve the availability, the second the reliability and safety. For these problems, the relation to methods of failure diagnosis for combinational circuits is required. Moreover, the techniques are demonstrated for a number of systems which can be represented by fault trees. (orig./RW) [de

  11. Decision table development and application to the construction of fault trees

    International Nuclear Information System (INIS)

    Salem, S.L.; Wu, J.S.; Apostolakis, G.

    1979-01-01

    A systematic methodology for the construction of fault trees based on the use of decision tables has been developed. These tables are used to describe each possible output state of a component as a set of combinations of states of inputs and internal operational or T states. Two methods for modeling component behavior via decision tables have been developed, one inductive and one deductive. These methods are useful for creating decision tables that realistically model the operational and failure modes of electrical, mechanical, and hydraulic components as well as human interactions inhibit conditions and common-cause events. A computer code CAT (Computer Automated Tree) has been developed to automatically produce fault trees from decision tables. A simple electrical system was chosen to illustrate the basic features of the decision table approach and to provide an example of an actual fault tree produced by this code. This example demonstrates the potential utility of such an automated approach to fault tree construction once a basic set of general decision tables has been developed

  12. Analysis of large fault trees based on functional decomposition

    International Nuclear Information System (INIS)

    Contini, Sergio; Matuzas, Vaidas

    2011-01-01

    With the advent of the Binary Decision Diagrams (BDD) approach in fault tree analysis, a significant enhancement has been achieved with respect to previous approaches, both in terms of efficiency and accuracy of the overall outcome of the analysis. However, the exponential increase of the number of nodes with the complexity of the fault tree may prevent the construction of the BDD. In these cases, the only way to complete the analysis is to reduce the complexity of the BDD by applying the truncation technique, which nevertheless implies the problem of estimating the truncation error or upper and lower bounds of the top-event unavailability. This paper describes a new method to analyze large coherent fault trees which can be advantageously applied when the working memory is not sufficient to construct the BDD. It is based on the decomposition of the fault tree into simpler disjoint fault trees containing a lower number of variables. The analysis of each simple fault tree is performed by using all the computational resources. The results from the analysis of all simpler fault trees are re-combined to obtain the results for the original fault tree. Two decomposition methods are herewith described: the first aims at determining the minimal cut sets (MCS) and the upper and lower bounds of the top-event unavailability; the second can be applied to determine the exact value of the top-event unavailability. Potentialities, limitations and possible variations of these methods will be discussed with reference to the results of their application to some complex fault trees.

  13. Analysis of large fault trees based on functional decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Contini, Sergio, E-mail: sergio.contini@jrc.i [European Commission, Joint Research Centre, Institute for the Protection and Security of the Citizen, 21020 Ispra (Italy); Matuzas, Vaidas [European Commission, Joint Research Centre, Institute for the Protection and Security of the Citizen, 21020 Ispra (Italy)

    2011-03-15

    With the advent of the Binary Decision Diagrams (BDD) approach in fault tree analysis, a significant enhancement has been achieved with respect to previous approaches, both in terms of efficiency and accuracy of the overall outcome of the analysis. However, the exponential increase of the number of nodes with the complexity of the fault tree may prevent the construction of the BDD. In these cases, the only way to complete the analysis is to reduce the complexity of the BDD by applying the truncation technique, which nevertheless implies the problem of estimating the truncation error or upper and lower bounds of the top-event unavailability. This paper describes a new method to analyze large coherent fault trees which can be advantageously applied when the working memory is not sufficient to construct the BDD. It is based on the decomposition of the fault tree into simpler disjoint fault trees containing a lower number of variables. The analysis of each simple fault tree is performed by using all the computational resources. The results from the analysis of all simpler fault trees are re-combined to obtain the results for the original fault tree. Two decomposition methods are herewith described: the first aims at determining the minimal cut sets (MCS) and the upper and lower bounds of the top-event unavailability; the second can be applied to determine the exact value of the top-event unavailability. Potentialities, limitations and possible variations of these methods will be discussed with reference to the results of their application to some complex fault trees.

  14. Study of fault diagnosis software design for complex system based on fault tree

    International Nuclear Information System (INIS)

    Yuan Run; Li Yazhou; Wang Jianye; Hu Liqin; Wang Jiaqun; Wu Yican

    2012-01-01

    Complex systems always have high-level reliability and safety requirements, and same does their diagnosis work. As a great deal of fault tree models have been acquired during the design and operation phases, a fault diagnosis method which combines fault tree analysis with knowledge-based technology has been proposed. The prototype of fault diagnosis software has been realized and applied to mobile LIDAR system. (authors)

  15. A compendium of computer codes in fault tree analysis

    International Nuclear Information System (INIS)

    Lydell, B.

    1981-03-01

    In the past ten years principles and methods for a unified system reliability and safety analysis have been developed. Fault tree techniques serve as a central feature of unified system analysis, and there exists a specific discipline within system reliability concerned with the theoretical aspects of fault tree evaluation. Ever since the fault tree concept was established, computer codes have been developed for qualitative and quantitative analyses. In particular the presentation of the kinetic tree theory and the PREP-KITT code package has influenced the present use of fault trees and the development of new computer codes. This report is a compilation of some of the better known fault tree codes in use in system reliability. Numerous codes are available and new codes are continuously being developed. The report is designed to address the specific characteristics of each code listed. A review of the theoretical aspects of fault tree evaluation is presented in an introductory chapter, the purpose of which is to give a framework for the validity of the different codes. (Auth.)

  16. Algorithmic fault tree construction by component-based system modeling

    International Nuclear Information System (INIS)

    Majdara, Aref; Wakabayashi, Toshio

    2008-01-01

    Computer-aided fault tree generation can be easier, faster and less vulnerable to errors than the conventional manual fault tree construction. In this paper, a new approach for algorithmic fault tree generation is presented. The method mainly consists of a component-based system modeling procedure an a trace-back algorithm for fault tree synthesis. Components, as the building blocks of systems, are modeled using function tables and state transition tables. The proposed method can be used for a wide range of systems with various kinds of components, if an inclusive component database is developed. (author)

  17. AFTC Code for Automatic Fault Tree Construction: Users Manual

    International Nuclear Information System (INIS)

    Gopika Vinod; Saraf, R.K.; Babar, A.K.

    1999-04-01

    Fault Trees perform a predominant role in reliability and safety analysis of system. Manual construction of fault tree is a very time consuming task and moreover, it won't give a formalized result, since it relies highly on analysts experience and heuristics. This necessitates a computerised fault tree construction, which is still attracting interest of reliability analysts. AFTC software is a user friendly software model for constructing fault trees based on decision tables. Software is equipped with libraries of decision tables for components commonly used in various Nuclear Power Plant (NPP) systems. User is expected to make a nodal diagram of the system, for which fault tree is to be constructed, from the flow sheets available. The text nodal diagram goes as the sole input defining the system flow chart. AFTC software is a rule based expert system which draws the fault tree from the system flow chart and component decision tables. AFTC software gives fault tree in both text and graphic format. Help is provided as how to enter system flow chart and component decision tables. The software is developed in 'C' language. Software is verified with simplified version of the fire water system of an Indian PHWR. Code conversion will be undertaken to create a window based version. (author)

  18. Fault tree analysis: concepts and techniques

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1976-01-01

    Concepts and techniques of fault tree analysis have been developed over the past decade and now predictions from this type analysis are important considerations in the design of many systems such as aircraft, ships and their electronic systems, missiles, and nuclear reactor systems. Routine, hardware-oriented fault tree construction can be automated; however, considerable effort is needed in this area to get the methodology into production status. When this status is achieved, the entire analysis of hardware systems will be automated except for the system definition step. Automated analysis is not undesirable; to the contrary, when verified on adequately complex systems, automated analysis could well become a routine analysis. It could also provide an excellent start for a more in-depth fault tree analysis that includes environmental effects, common mode failure, and human errors. The automated analysis is extremely fast and frees the analyst from the routine hardware-oriented fault tree construction, as well as eliminates logic errors and errors of oversight in this part of the analysis. Automated analysis then affords the analyst a powerful tool to allow his prime efforts to be devoted to unearthing more subtle aspects of the modes of failure of the system

  19. Breaking the fault tree circular logic

    International Nuclear Information System (INIS)

    Lankin, M.

    2000-01-01

    Event tree - fault tree approach to model failures of nuclear plants as well as of other complex facilities is noticeably dominant now. This approach implies modeling an object in form of unidirectional logical graph - tree, i.e. graph without circular logic. However, genuine nuclear plants intrinsically demonstrate quite a few logical loops (circular logic), especially where electrical systems are involved. This paper shows the incorrectness of existing practice of circular logic breaking by elimination of part of logical dependencies and puts forward a formal algorithm, which enables the analyst to correctly model the failure of complex object, which involves logical dependencies between system and components, in form of fault tree. (author)

  20. [The Application of the Fault Tree Analysis Method in Medical Equipment Maintenance].

    Science.gov (United States)

    Liu, Hongbin

    2015-11-01

    In this paper, the traditional fault tree analysis method is presented, detailed instructions for its application characteristics in medical instrument maintenance is made. It is made significant changes when the traditional fault tree analysis method is introduced into the medical instrument maintenance: gave up the logic symbolic, logic analysis and calculation, gave up its complicated programs, and only keep its image and practical fault tree diagram, and the fault tree diagram there are also differences: the fault tree is no longer a logical tree but the thinking tree in troubleshooting, the definition of the fault tree's nodes is different, the composition of the fault tree's branches is also different.

  1. Efficient reduction and modularization for large fault trees stored by pages

    International Nuclear Information System (INIS)

    Chen, Shanqi; Wang, Jin; Wang, Jiaqun; Wang, Fang; Hu, Liqin

    2016-01-01

    Highlights: • New fault tree pre-processing methods used in RiskA are presented. • Including the fault tree paging storage, simplification and modularization. • For getting MCS for fault trees containing more than 10,000 gates and events. • Reduce computer resources needs (RAM) and improve computation speed. - Abstract: Fault Tree Analysis (FTA), an indispensable tool used in Probabilistic Risk Assessment (PRA), has been used throughout the commercial nuclear power industry for safety and reliability analyses. However, large fault tree analysis, such as those used in nuclear power plant requires significant computer resources, which makes the analysis of PRA model inefficient and time consuming. This paper describes a fault tree pre-processing method used in the reliability and probabilistic safety assessment program RiskA that is capable of generating minimal cutsets for fault trees containing more than 10,000 gates and basic events. The novel feature of this method is not only that Boolean reduction rules are used but also that a new objective of simplification is proposed. Moreover, since the method aims to find more fault tree modules by the linear-time algorithm, it can optimize fault tree modularization, which further reduces the computational time of large fault tree analysis.

  2. A fault tree analysis strategy using binary decision diagrams

    International Nuclear Information System (INIS)

    Reay, Karen A.; Andrews, John D.

    2002-01-01

    The use of binary decision diagrams (BDDs) in fault tree analysis provides both an accurate and efficient means of analysing a system. There is a problem, however, with the conversion process of the fault tree to the BDD. The variable ordering scheme chosen for the construction of the BDD has a crucial effect on its resulting size and previous research has failed to identify any scheme that is capable of producing BDDs for all fault trees. This paper proposes an analysis strategy aimed at increasing the likelihood of obtaining a BDD for any given fault tree, by ensuring the associated calculations are as efficient as possible. The method implements simplification techniques, which are applied to the fault tree to obtain a set of 'minimal' subtrees, equivalent to the original fault tree structure. BDDs are constructed for each, using ordering schemes most suited to their particular characteristics. Quantitative analysis is performed simultaneously on the set of BDDs to obtain the top event probability, the system unconditional failure intensity and the criticality of the basic events

  3. Posbist fault tree analysis of coherent systems

    International Nuclear Information System (INIS)

    Huang, H.-Z.; Tong Xin; Zuo, Ming J.

    2004-01-01

    When the failure probability of a system is extremely small or necessary statistical data from the system is scarce, it is very difficult or impossible to evaluate its reliability and safety with conventional fault tree analysis (FTA) techniques. New techniques are needed to predict and diagnose such a system's failures and evaluate its reliability and safety. In this paper, we first provide a concise overview of FTA. Then, based on the posbist reliability theory, event failure behavior is characterized in the context of possibility measures and the structure function of the posbist fault tree of a coherent system is defined. In addition, we define the AND operator and the OR operator based on the minimal cut of a posbist fault tree. Finally, a model of posbist fault tree analysis (posbist FTA) of coherent systems is presented. The use of the model for quantitative analysis is demonstrated with a real-life safety system

  4. Research on Fault Diagnosis for Pumping Station Based on T-S Fuzzy Fault Tree and Bayesian Network

    Directory of Open Access Journals (Sweden)

    Zhuqing Bi

    2017-01-01

    Full Text Available According to the characteristics of fault diagnosis for pumping station, such as the complex structure, multiple mappings, and numerous uncertainties, a new approach combining T-S fuzzy gate fault tree and Bayesian network (BN is proposed. On the one hand, traditional fault tree method needs the logical relationship between events and probability value of events and can only represent the events with two states. T-S fuzzy gate fault tree method can solve these disadvantages but still has weaknesses in complex reasoning and only one-way reasoning. On the other hand, the BN is suitable for fault diagnosis of pumping station because of its powerful ability to deal with uncertain information. However, it is difficult to determine the structure and conditional probability tables of the BN. Therefore, the proposed method integrates the advantages of the two methods. Finally, the feasibility of the method is verified through a fault diagnosis model of the rotor in the pumping unit, the accuracy of the method is verified by comparing with the methods based on traditional Bayesian network and BP neural network, respectively, when the historical data is sufficient, and the results are more superior to the above two when the historical data is insufficient.

  5. Fault tree analysis for vital area identification

    International Nuclear Information System (INIS)

    Varnado, G.B.; Ortiz, N.R.

    1978-01-01

    This paper discusses the use of fault tree analysis to identify those areas of nuclear fuel cycle facilities which must be protected to prevent acts of sabotage that could lead to sifnificant release of radioactive material. By proper manipulation of the fault trees for a plant, an analyst can identify vital areas in a manner consistent with regulatory definitions. This paper discusses the general procedures used in the analysis of any nuclear facility. In addition, a structured, generic approach to the development of the fault trees for nuclear power reactors is presented along with selected results of the application of the generic approach to several plants

  6. A new methodology for the computer-aided construction of fault trees

    International Nuclear Information System (INIS)

    Salem, S.L.; Apostolakis, G.E.; Okrent, D.

    1977-01-01

    A methodology for systematically constructing fault trees for general complex systems is developed. A means of modeling component behaviour via decision tables is presented, and a procedure, and a procedure for constructing and editing fault trees, either manually or by computer, is developed. The techniques employed result in a complete fault tree in standard form. In order to demonstrate the methodology, the computer program CAT was developed and is used to construct trees for a nuclear system. By analyzing and comparing these fault trees, several conclusions are reached. First, such an approach can be used to produce fault trees that accurately describe system behaviour. Second, multiple trees can be rapidly produced by defining various TOP events, including system success. Finally, the accuracy and utility of such trees is shown to depend upon the careful development of the decision table models by the analyst, and of the overall system definition itself. Thus the method is seen to be a tool for assisting in the work of fault tree construction rather than a replacement for the careful work of the fault tree analyst. (author)

  7. Object-oriented fault tree evaluation program for quantitative analyses

    Science.gov (United States)

    Patterson-Hine, F. A.; Koen, B. V.

    1988-01-01

    Object-oriented programming can be combined with fault free techniques to give a significantly improved environment for evaluating the safety and reliability of large complex systems for space missions. Deep knowledge about system components and interactions, available from reliability studies and other sources, can be described using objects that make up a knowledge base. This knowledge base can be interrogated throughout the design process, during system testing, and during operation, and can be easily modified to reflect design changes in order to maintain a consistent information source. An object-oriented environment for reliability assessment has been developed on a Texas Instrument (TI) Explorer LISP workstation. The program, which directly evaluates system fault trees, utilizes the object-oriented extension to LISP called Flavors that is available on the Explorer. The object representation of a fault tree facilitates the storage and retrieval of information associated with each event in the tree, including tree structural information and intermediate results obtained during the tree reduction process. Reliability data associated with each basic event are stored in the fault tree objects. The object-oriented environment on the Explorer also includes a graphical tree editor which was modified to display and edit the fault trees.

  8. Fuzzy probability based fault tree analysis to propagate and quantify epistemic uncertainty

    International Nuclear Information System (INIS)

    Purba, Julwan Hendry; Sony Tjahyani, D.T.; Ekariansyah, Andi Sofrany; Tjahjono, Hendro

    2015-01-01

    Highlights: • Fuzzy probability based fault tree analysis is to evaluate epistemic uncertainty in fuzzy fault tree analysis. • Fuzzy probabilities represent likelihood occurrences of all events in a fault tree. • A fuzzy multiplication rule quantifies epistemic uncertainty of minimal cut sets. • A fuzzy complement rule estimate epistemic uncertainty of the top event. • The proposed FPFTA has successfully evaluated the U.S. Combustion Engineering RPS. - Abstract: A number of fuzzy fault tree analysis approaches, which integrate fuzzy concepts into the quantitative phase of conventional fault tree analysis, have been proposed to study reliabilities of engineering systems. Those new approaches apply expert judgments to overcome the limitation of the conventional fault tree analysis when basic events do not have probability distributions. Since expert judgments might come with epistemic uncertainty, it is important to quantify the overall uncertainties of the fuzzy fault tree analysis. Monte Carlo simulation is commonly used to quantify the overall uncertainties of conventional fault tree analysis. However, since Monte Carlo simulation is based on probability distribution, this technique is not appropriate for fuzzy fault tree analysis, which is based on fuzzy probabilities. The objective of this study is to develop a fuzzy probability based fault tree analysis to overcome the limitation of fuzzy fault tree analysis. To demonstrate the applicability of the proposed approach, a case study is performed and its results are then compared to the results analyzed by a conventional fault tree analysis. The results confirm that the proposed fuzzy probability based fault tree analysis is feasible to propagate and quantify epistemic uncertainties in fault tree analysis

  9. Fault tree analysis of a research reactor

    International Nuclear Information System (INIS)

    Hall, J.A.; O'Dacre, D.F.; Chenier, R.J.; Arbique, G.M.

    1986-08-01

    Fault Tree Analysis Techniques have been used to assess the safety system of the ZED-2 Research Reactor at the Chalk River Nuclear Laboratories. This turned out to be a strong test of the techniques involved. The resulting fault tree was large and because of inter-links in the system structure the tree was not modularized. In addition, comprehensive documentation was required. After a brief overview of the reactor and the analysis, this paper concentrates on the computer tools that made the job work. Two types of tools were needed; text editing and forms management capability for large volumes of component and system data, and the fault tree codes themselves. The solutions (and failures) are discussed along with the tools we are already developing for the next analysis

  10. Naive Fault Tree : formulation of the approach

    NARCIS (Netherlands)

    Rajabalinejad, M

    2017-01-01

    Naive Fault Tree (NFT) accepts a single value or a range of values for each basic event and returns values for the top event. This accommodates the need of commonly used Fault Trees (FT) for precise data making them prone to data concerns and limiting their area of application. This paper extends

  11. A knowledge-based approach to the evaluation of fault trees

    International Nuclear Information System (INIS)

    Hwang, Yann-Jong; Chow, Louis R.; Huang, Henry C.

    1996-01-01

    A list of critical components is useful for determining the potential problems of a complex system. However, to find this list through evaluating the fault trees is expensive and time consuming. This paper intends to propose an integrated software program which consists of a fault tree constructor, a knowledge base, and an efficient algorithm for evaluating minimal cut sets of a large fault tree. The proposed algorithm uses the approaches of top-down heuristic searching and the probability-based truncation. That makes the evaluation of fault trees obviously efficient and provides critical components for solving the potential problems in complex systems. Finally, some practical fault trees are included to illustrate the results

  12. Automatic fault tree generation in the EPR PSA project

    International Nuclear Information System (INIS)

    Villatte, N; Nonclercq, P.; Taupy, S.

    2012-01-01

    Tools (KB3 and Atelier EPS) have been developed at EDF to assist the analysts in building fault trees for PSA (Probabilistic Safety Assessment) and importing them into RiskSpectrum (RiskSpectrum is a Swedish code used at EDF for PSA). System modelling is performed using KB3 software with a knowledge base describing generic classes of components with their behaviour and failure modes. Using these classes of components, the analyst can describe (using a graphical system editor): a simplified system diagram from the mechanical system drawings and functional descriptions, the missions of the studied system (in a form of high level fault trees) and its different configurations for the missions. He can also add specific knowledge about the system. Then, the analyst chooses missions and configurations to specify and launch fault trees generations. From the system description, KB3 produces by backward-chaining on rules, detailed system fault trees. These fault trees are finally imported into RiskSpectrum (they are converted by Atelier EPS into a format readable by RiskSpectrum). KB3 and Atelier EPS have been used to create the majority of the fault trees for the EDF EPR Probabilistic Safety Analysis conducted from November 2009 to March 2010. 25 systems were modelled, and 127 fault trees were automatically generated in a rather short time by different analysts with the help of these tools. A feedback shows a lot of advantages to use KB3 and Atelier EPS: homogeneity and consistency between the different generated fault trees, traceability of modelling, control of modelling and last but not least: the automation of detailed fault tree creation relieves the human analyst of this tedious task so that he can focus his attention on more important tasks: modelling the failure of a function. This industrial application has also helped us gather an interesting feedback from the analysts that should help us improve the handling of the tools. We propose in this paper indeed some

  13. Accident Fault Trees for Defense Waste Processing Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sarrack, A.G.

    1999-06-22

    The purpose of this report is to document fault tree analyses which have been completed for the Defense Waste Processing Facility (DWPF) safety analysis. Logic models for equipment failures and human error combinations that could lead to flammable gas explosions in various process tanks, or failure of critical support systems were developed for internal initiating events and for earthquakes. These fault trees provide frequency estimates for support systems failures and accidents that could lead to radioactive and hazardous chemical releases both on-site and off-site. Top event frequency results from these fault trees will be used in further APET analyses to calculate accident risk associated with DWPF facility operations. This report lists and explains important underlying assumptions, provides references for failure data sources, and briefly describes the fault tree method used. Specific commitments from DWPF to provide new procedural/administrative controls or system design changes are listed in the ''Facility Commitments'' section. The purpose of the ''Assumptions'' section is to clarify the basis for fault tree modeling, and is not necessarily a list of items required to be protected by Technical Safety Requirements (TSRs).

  14. A practical method for accurate quantification of large fault trees

    International Nuclear Information System (INIS)

    Choi, Jong Soo; Cho, Nam Zin

    2007-01-01

    This paper describes a practical method to accurately quantify top event probability and importance measures from incomplete minimal cut sets (MCS) of a large fault tree. The MCS-based fault tree method is extensively used in probabilistic safety assessments. Several sources of uncertainties exist in MCS-based fault tree analysis. The paper is focused on quantification of the following two sources of uncertainties: (1) the truncation neglecting low-probability cut sets and (2) the approximation in quantifying MCSs. The method proposed in this paper is based on a Monte Carlo simulation technique to estimate probability of the discarded MCSs and the sum of disjoint products (SDP) approach complemented by the correction factor approach (CFA). The method provides capability to accurately quantify the two uncertainties and estimate the top event probability and importance measures of large coherent fault trees. The proposed fault tree quantification method has been implemented in the CUTREE code package and is tested on the two example fault trees

  15. New algorithm to detect modules in a fault tree for a PSA

    International Nuclear Information System (INIS)

    Jung, Woo Sik

    2015-01-01

    A module or independent subtree is a part of a fault tree whose child gates or basic events are not repeated in the remaining part of the fault tree. Modules are necessarily employed in order to reduce the computational costs of fault tree quantification. This paper presents a new linear time algorithm to detect modules of large fault trees. The size of cut sets can be substantially reduced by replacing independent subtrees in a fault tree with super-components. Chatterjee and Birnbaum developed properties of modules, and demonstrated their use in the fault tree analysis. Locks expanded the concept of modules to non-coherent fault trees. Independent subtrees were manually identified while coding a fault tree for computer analysis. However, nowadays, the independent subtrees are automatically identified by the fault tree solver. A Dutuit and Rauzy (DR) algorithm to detect modules of a fault tree for coherent or non-coherent fault tree was proposed in 1996. It has been well known that this algorithm quickly detects modules since it is a linear time algorithm. The new algorithm minimizes computational memory and quickly detects modules. Furthermore, it can be easily implemented into industry fault tree solvers that are based on traditional Boolean algebra, binary decision diagrams (BDDs), or Zero-suppressed BDDs. The new algorithm employs only two scalar variables in Eqs. to that are volatile information. After finishing the traversal and module detection of each node, the volatile information is destroyed. Thus, the new algorithm does not employ any other additional computational memory and operations. It is recommended that this method be implemented into fault tree solvers for efficient probabilistic safety assessment (PSA) of nuclear power plants

  16. New algorithm to detect modules in a fault tree for a PSA

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Woo Sik [Sejong University, Seoul (Korea, Republic of)

    2015-05-15

    A module or independent subtree is a part of a fault tree whose child gates or basic events are not repeated in the remaining part of the fault tree. Modules are necessarily employed in order to reduce the computational costs of fault tree quantification. This paper presents a new linear time algorithm to detect modules of large fault trees. The size of cut sets can be substantially reduced by replacing independent subtrees in a fault tree with super-components. Chatterjee and Birnbaum developed properties of modules, and demonstrated their use in the fault tree analysis. Locks expanded the concept of modules to non-coherent fault trees. Independent subtrees were manually identified while coding a fault tree for computer analysis. However, nowadays, the independent subtrees are automatically identified by the fault tree solver. A Dutuit and Rauzy (DR) algorithm to detect modules of a fault tree for coherent or non-coherent fault tree was proposed in 1996. It has been well known that this algorithm quickly detects modules since it is a linear time algorithm. The new algorithm minimizes computational memory and quickly detects modules. Furthermore, it can be easily implemented into industry fault tree solvers that are based on traditional Boolean algebra, binary decision diagrams (BDDs), or Zero-suppressed BDDs. The new algorithm employs only two scalar variables in Eqs. to that are volatile information. After finishing the traversal and module detection of each node, the volatile information is destroyed. Thus, the new algorithm does not employ any other additional computational memory and operations. It is recommended that this method be implemented into fault tree solvers for efficient probabilistic safety assessment (PSA) of nuclear power plants.

  17. KCUT, code to generate minimal cut sets for fault trees

    International Nuclear Information System (INIS)

    Han, Sang Hoon

    2008-01-01

    1 - Description of program or function: KCUT is a software to generate minimal cut sets for fault trees. 2 - Methods: Expand a fault tree into cut sets and delete non minimal cut sets. 3 - Restrictions on the complexity of the problem: Size and complexity of the fault tree

  18. Application Research of Fault Tree Analysis in Grid Communication System Corrective Maintenance

    Science.gov (United States)

    Wang, Jian; Yang, Zhenwei; Kang, Mei

    2018-01-01

    This paper attempts to apply the fault tree analysis method to the corrective maintenance field of grid communication system. Through the establishment of the fault tree model of typical system and the engineering experience, the fault tree analysis theory is used to analyze the fault tree model, which contains the field of structural function, probability importance and so on. The results show that the fault tree analysis can realize fast positioning and well repairing of the system. Meanwhile, it finds that the analysis method of fault tree has some guiding significance to the reliability researching and upgrading f the system.

  19. Methods of fault tree analysis and their limits

    International Nuclear Information System (INIS)

    Weber, G.G.

    1984-12-01

    Some recent methodological developments of fault tree analysis are discussed and limits of fault tree analysis and a criterion for admissibility of structure functions are given. It is shown that there are interesting relations to switching theory and to stochastic processes. (orig./HP) [de

  20. Systematic evaluation of fault trees using real-time model checker UPPAAL

    International Nuclear Information System (INIS)

    Cha, Sungdeok; Son, Hanseong; Yoo, Junbeom; Jee, Eunkyung; Seong, Poong Hyun

    2003-01-01

    Fault tree analysis, the most widely used safety analysis technique in industry, is often applied manually. Although techniques such as cutset analysis or probabilistic analysis can be applied on the fault tree to derive further insights, they are inadequate in locating flaws when failure modes in fault tree nodes are incorrectly identified or when causal relationships among failure modes are inaccurately specified. In this paper, we demonstrate that model checking technique is a powerful tool that can formally validate the accuracy of fault trees. We used a real-time model checker UPPAAL because the system we used as the case study, nuclear power emergency shutdown software named Wolsong SDS2, has real-time requirements. By translating functional requirements written in SCR-style tabular notation into timed automata, two types of properties were verified: (1) if failure mode described in a fault tree node is consistent with the system's behavioral model; and (2) whether or not a fault tree node has been accurately decomposed. A group of domain engineers with detailed technical knowledge of Wolsong SDS2 and safety analysis techniques developed fault tree used in the case study. However, model checking technique detected subtle ambiguities present in the fault tree

  1. Guideliness for system modeling: fault tree [analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hwan; Yang, Joon Eon; Kang, Dae Il; Hwang, Mee Jeong

    2004-07-01

    This document, the guidelines for system modeling related to Fault Tree Analysis(FTA), is intended to provide the guidelines with the analyzer to construct the fault trees in the level of the capability category II of ASME PRA standard. Especially, they are to provide the essential and basic guidelines and the related contents to be used in support of revising the Ulchin 3 and 4 PSA model for risk monitor within the capability category II of ASME PRA standard. Normally the main objective of system analysis is to assess the reliability of system modeled by Event Tree Analysis (ETA). A variety of analytical techniques can be used for the system analysis, however, FTA method is used in this procedures guide. FTA is the method used for representing the failure logic of plant systems deductively using AND, OR or NOT gates. The fault tree should reflect all possible failure modes that may contribute to the system unavailability. This should include contributions due to the mechanical failures of the components, Common Cause Failures (CCFs), human errors and outages for testing and maintenance. This document identifies and describes the definitions and the general procedures of FTA and the essential and basic guidelines for reving the fault trees. Accordingly, the guidelines for FTA will be capable to guide the FTA to the level of the capability category II of ASME PRA standard.

  2. Guideliness for system modeling: fault tree [analysis

    International Nuclear Information System (INIS)

    Lee, Yoon Hwan; Yang, Joon Eon; Kang, Dae Il; Hwang, Mee Jeong

    2004-07-01

    This document, the guidelines for system modeling related to Fault Tree Analysis(FTA), is intended to provide the guidelines with the analyzer to construct the fault trees in the level of the capability category II of ASME PRA standard. Especially, they are to provide the essential and basic guidelines and the related contents to be used in support of revising the Ulchin 3 and 4 PSA model for risk monitor within the capability category II of ASME PRA standard. Normally the main objective of system analysis is to assess the reliability of system modeled by Event Tree Analysis (ETA). A variety of analytical techniques can be used for the system analysis, however, FTA method is used in this procedures guide. FTA is the method used for representing the failure logic of plant systems deductively using AND, OR or NOT gates. The fault tree should reflect all possible failure modes that may contribute to the system unavailability. This should include contributions due to the mechanical failures of the components, Common Cause Failures (CCFs), human errors and outages for testing and maintenance. This document identifies and describes the definitions and the general procedures of FTA and the essential and basic guidelines for reving the fault trees. Accordingly, the guidelines for FTA will be capable to guide the FTA to the level of the capability category II of ASME PRA standard

  3. An HVAC [heating, ventilation, and air-conditioning] fault-tree analysis for WIPP [Waste Isolation Pilot Plant] integrated risk assessment

    International Nuclear Information System (INIS)

    Kirby, P.N.; Iacovino, J.M.

    1990-01-01

    In order to evaluate the public health risk of potential radioactive releases from operation of the Waste Isolation Pilot Plant (WIPP), a probabilistic risk assessment of waste-handling operations was conducted. One major aspect of this risk assessment involved fault-tree analysis of the plant heating, ventilation, and air-conditioning (HVAC) systems, which constitute the final barrier between waste-handling operations and the environment. The WIPP site is designed to receive and store two types of waste: contact-handled transuranic (CH TRU) wastes to be shipped in 208-ell drums and remote-handled (RH) TRU wastes to be shipped in shielded casks. The identification of accident sequences for CH waste operations revealed no identified accidents that could release significant radioactive particulates to the environment without a failure in the HVAC systems. When the HVAC fault-tree results were combined with other critical system fault trees and the analysis of waste-handling accident sequences, the approximation of the overall WIPP plant risk due to airborne releases was determined to be 2.6 x 10 -7 fatalities per year for the population within a 50-mile radius of the WIPP site. This risk was demonstrated to be well below the risk of fatality from other voluntary and involuntary activities for the population within the vicinity of the WIPP

  4. Use of fault and decision tree analyses to protect against industrial sabotage

    International Nuclear Information System (INIS)

    Fullwood, R.R.; Erdmann, R.C.

    1975-01-01

    Fault tree and decision tree analyses provide systematic bases for evaluation of safety systems and procedures. Heuristically, this paper shows applications of these methods for industrial sabotage analysis at a reprocessing plant. Fault trees constructed by ''leak path'' analysis for completeness through path inventory. The escape fault tree is readily developed by this method and using the reciprocal character of the trees, the attack fault tree is constructed. After construction, the events on the fault tree are corrected for their nonreciprocal character. The fault trees are algebraically solved and the protection that is afforded is ranked by the number of barriers that must be penetrated. No attempt is made to assess the barrier penetration probabilities or penetration time duration. Event trees are useful for dynamic plant protection analysis through their time-sequencing character. To illustrate their usefulness, a simple attack scenario is devised and event-tree analyzed. Two saboteur success paths and 21 failure paths are found. This example clearly shows the event tree usefulness for concisely presenting the time sequencing of key decision points. However, event trees have the disadvantage of being scenario dependent, therefore requiring a separate event tree for each scenario

  5. Reset Tree-Based Optical Fault Detection

    Directory of Open Access Journals (Sweden)

    Howon Kim

    2013-05-01

    Full Text Available In this paper, we present a new reset tree-based scheme to protect cryptographic hardware against optical fault injection attacks. As one of the most powerful invasive attacks on cryptographic hardware, optical fault attacks cause semiconductors to misbehave by injecting high-energy light into a decapped integrated circuit. The contaminated result from the affected chip is then used to reveal secret information, such as a key, from the cryptographic hardware. Since the advent of such attacks, various countermeasures have been proposed. Although most of these countermeasures are strong, there is still the possibility of attack. In this paper, we present a novel optical fault detection scheme that utilizes the buffers on a circuit’s reset signal tree as a fault detection sensor. To evaluate our proposal, we model radiation-induced currents into circuit components and perform a SPICE simulation. The proposed scheme is expected to be used as a supplemental security tool.

  6. MFAULT: a computer program for analyzing fault trees

    International Nuclear Information System (INIS)

    Pelto, P.J.; Purcell, W.L.

    1977-11-01

    A description and user instructions are presented for MFAULT, a FORTRAN computer program for fault tree analysis. MFAULT identifies the cut sets of a fault tree, calculates their probabilities, and screens the cut sets on the basis of specified cut-offs on probability and/or cut set length. MFAULT is based on an efficient upward-working algorithm for cut set identification. The probability calculations are based on the assumption of small probabilities and constant hazard rates (i.e., exponential failure distributions). Cut sets consisting of repairable components (basic events) only, non-repairable components only, or mixtures of both types can be evaluated. Components can be on-line or standby. Unavailability contributions from pre-existing failures, failures on demand, and testing and maintenance down-time can be handled. MFAULT can analyze fault trees with AND gates, OR gates, inhibit gates, on switches (houses) and off switches. The code is presently capable of finding up to ten event cut sets from a fault tree with up to 512 basic events and 400 gates. It is operational on the CONTROL DATA CYBER 74 computer. 11 figures

  7. New approaches to evaluating fault trees

    International Nuclear Information System (INIS)

    Sinnamon, R.M.; Andrews, J.D.

    1997-01-01

    Fault Tree Analysis is now a widely accepted technique to assess the probability and frequency of system failure in many industries. For complex systems an analysis may produce hundreds of thousands of combinations of events which can cause system failure (minimal cut sets). The determination of these cut sets can be a very time consuming process even on modern high speed digital computers. Computerised methods, such as bottom-up or top-down approaches, to conduct this analysis are now so well developed that further refinement is unlikely to result in vast reductions in computer time. It is felt that substantial improvement in computer utilisation will only result from a completely new approach. This paper describes the use of a Binary Decision Diagram for Fault Tree Analysis and some ways in which it can be efficiently implemented on a computer. In particular, attention is given to the production of a minimum form of the Binary Decision Diagram by considering the ordering that has to be given to the basic events of the fault tree

  8. System assessment using modular logic fault tree methodology

    International Nuclear Information System (INIS)

    Troncoso Fleitas, M.

    1996-01-01

    In the process of a Probabilistic Safety analysis (PSA) study a large number of fault trees are generated by different specialist. Modular Logic Fault Tree Methodology pave the way the way to systematize the procedures and to unify the criteria in the process of systems modulation. An example of of the application of this methodology is shown

  9. Sequence Algebra, Sequence Decision Diagrams and Dynamic Fault Trees

    International Nuclear Information System (INIS)

    Rauzy, Antoine B.

    2011-01-01

    A large attention has been focused on the Dynamic Fault Trees in the past few years. By adding new gates to static (regular) Fault Trees, Dynamic Fault Trees aim to take into account dependencies among events. Merle et al. proposed recently an algebraic framework to give a formal interpretation to these gates. In this article, we extend Merle et al.'s work by adopting a slightly different perspective. We introduce Sequence Algebras that can be seen as Algebras of Basic Events, representing failures of non-repairable components. We show how to interpret Dynamic Fault Trees within this framework. Finally, we propose a new data structure to encode sets of sequences of Basic Events: Sequence Decision Diagrams. Sequence Decision Diagrams are very much inspired from Minato's Zero-Suppressed Binary Decision Diagrams. We show that all operations of Sequence Algebras can be performed on this data structure.

  10. Commercial application of fault tree analysis

    International Nuclear Information System (INIS)

    Crosetti, P.A.; Bruce, R.A.

    1970-01-01

    The potential for general application of Fault Tree Analysis to commercial products appears attractive based not only on the successful extension from the aerospace safety technology to the nuclear reactor reliability and availability technology, but also because combinatorial hazards are common to commercial operations and therefore lend themselves readily to evaluation by Fault Tree Analysis. It appears reasonable to conclude that the technique has application within the commercial industrial community where the occurrence of a specified consequence or final event would be of sufficient concern to management to justify such a rigorous analysis as an aid to decision making. (U.S.)

  11. Transforming incomplete fault tree to Ishikawa diagram as an alternative method for technology transfer

    Science.gov (United States)

    Batzias, Dimitris F.

    2012-12-01

    Fault Tree Analysis (FTA) can be used for technology transfer when the relevant problem (called 'top even' in FTA) is solved in a technology centre and the results are diffused to interested parties (usually Small Medium Enterprises - SMEs) that have not the proper equipment and the required know-how to solve the problem by their own. Nevertheless, there is a significant drawback in this procedure: the information usually provided by the SMEs to the technology centre, about production conditions and corresponding quality characteristics of the product, and (sometimes) the relevant expertise in the Knowledge Base of this centre may be inadequate to form a complete fault tree. Since such cases are quite frequent in practice, we have developed a methodology for transforming incomplete fault tree to Ishikawa diagram, which is more flexible and less strict in establishing causal chains, because it uses a surface phenomenological level with a limited number of categories of faults. On the other hand, such an Ishikawa diagram can be extended to simulate a fault tree as relevant knowledge increases. An implementation of this transformation, referring to anodization of aluminium, is presented.

  12. Lognormal Approximations of Fault Tree Uncertainty Distributions.

    Science.gov (United States)

    El-Shanawany, Ashraf Ben; Ardron, Keith H; Walker, Simon P

    2018-01-26

    Fault trees are used in reliability modeling to create logical models of fault combinations that can lead to undesirable events. The output of a fault tree analysis (the top event probability) is expressed in terms of the failure probabilities of basic events that are input to the model. Typically, the basic event probabilities are not known exactly, but are modeled as probability distributions: therefore, the top event probability is also represented as an uncertainty distribution. Monte Carlo methods are generally used for evaluating the uncertainty distribution, but such calculations are computationally intensive and do not readily reveal the dominant contributors to the uncertainty. In this article, a closed-form approximation for the fault tree top event uncertainty distribution is developed, which is applicable when the uncertainties in the basic events of the model are lognormally distributed. The results of the approximate method are compared with results from two sampling-based methods: namely, the Monte Carlo method and the Wilks method based on order statistics. It is shown that the closed-form expression can provide a reasonable approximation to results obtained by Monte Carlo sampling, without incurring the computational expense. The Wilks method is found to be a useful means of providing an upper bound for the percentiles of the uncertainty distribution while being computationally inexpensive compared with full Monte Carlo sampling. The lognormal approximation method and Wilks's method appear attractive, practical alternatives for the evaluation of uncertainty in the output of fault trees and similar multilinear models. © 2018 Society for Risk Analysis.

  13. PL-MOD: a computer code for modular fault tree analysis and evaluation

    International Nuclear Information System (INIS)

    Olmos, J.; Wolf, L.

    1978-01-01

    The computer code PL-MOD has been developed to implement the modular methodology to fault tree analysis. In the modular approach, fault tree structures are characterized by recursively relating the top tree event to all basic event inputs through a set of equations, each defining an independent modular event for the tree. The advantages of tree modularization lie in that it is a more compact representation than the minimal cut-set description and in that it is well suited for fault tree quantification because of its recursive form. In its present version, PL-MOD modularizes fault trees and evaluates top and intermediate event failure probabilities, as well as basic component and modular event importance measures, in a very efficient way. Thus, its execution time for the modularization and quantification of a PWR High Pressure Injection System reduced fault tree was 25 times faster than that necessary to generate its equivalent minimal cut-set description using the computer code MOCUS

  14. Fault tree technique: advances in probabilistic and logical analysis

    International Nuclear Information System (INIS)

    Clarotti, C.A.; Amendola, A.; Contini, S.; Squellati, G.

    1982-01-01

    Fault tree reliability analysis is used for assessing the risk associated to systems of increasing complexity (phased mission systems, systems with multistate components, systems with non-monotonic structure functions). Much care must be taken to make sure that fault tree technique is not used beyond its correct validity range. To this end a critical review of mathematical foundations of reliability fault tree analysis is carried out. Limitations are enlightened and potential solutions to open problems are suggested. Moreover an overview is given on the most recent developments in the implementation of an integrated software (SALP-MP, SALP-NOT, SALP-CAFT Codes) for the analysis of a wide class of systems

  15. Plotting and analysis of fault trees in safety evaluation of nuclear power plants

    International Nuclear Information System (INIS)

    Wild, A.

    1979-12-01

    Fault tree analysis is a useful tool in determining the safety and reliability of nuclear power plants. The main strength of the fault tree method, its ability to detect cross-links between systems, can be used only if fault trees are constructed for complete nuclear generating stations. Such trees are large and have to be handled by computers. A system is described for handling fault trees using small computers such as the HP-1000 with disc drive, graphics terminal and x-y plotter

  16. Microcomputer applications of, and modifications to, the modular fault trees

    International Nuclear Information System (INIS)

    Zimmerman, T.L.; Graves, N.L.; Payne, A.C. Jr.; Whitehead, D.W.

    1994-10-01

    The LaSalle Probabilistic Risk Assessment was the first major application of the modular logic fault trees after the IREP program. In the process of performing the analysis, many errors were discovered in the fault tree modules that led to difficulties in combining the modules to form the final system fault trees. These errors are corrected in the revised modules listed in this report. In addition, the application of the modules in terms of editing them and forming them into the system fault trees was inefficient. Originally, the editing had to be done line by line and no error checking was performed by the computer. This led to many typos and other logic errors in the construction of the modular fault tree files. Two programs were written to help alleviate this problem: (1) MODEDIT - This program allows an operator to retrieve a file for editing, edit the file for the plant specific application, perform some general error checking while the file is being modified, and store the file for later use, and (2) INDEX - This program checks that the modules that are supposed to form one fault tree all link up appropriately before the files are,loaded onto the mainframe computer. Lastly, the modules were not designed for relay type logic common in BWR designs but for solid state type logic. Some additional modules were defined for modeling relay logic, and an explanation and example of their use are included in this report

  17. MAPLE-II. A program for plotting fault trees

    International Nuclear Information System (INIS)

    Poucet, A.; Van Den Muyzenberg, C.L.

    1987-01-01

    The MAPLE II code is an improved version of the MAPLE program for plotting fault trees. MAPLE II has added features which make it a versatile tool for drawing large and complex logic trees. The code is developed as part of a package for computer aided fault tree construction and analysis in which it is integrated and used as a documentation tool. However the MAPLE II code can be used as a separate program which uses as input a structure function of a tree and a description of the events and gates which make up the tree. This report includes a short description of the code and of its features. Moreover it contains the how-to-use and some indications for implementing the code and for adapting it to different graphics systems

  18. Fault trees for decision making in systems analysis

    International Nuclear Information System (INIS)

    Lambert, H.E.

    1975-01-01

    The application of fault tree analysis (FTA) to system safety and reliability is presented within the framework of system safety analysis. The concepts and techniques involved in manual and automated fault tree construction are described and their differences noted. The theory of mathematical reliability pertinent to FTA is presented with emphasis on engineering applications. An outline of the quantitative reliability techniques of the Reactor Safety Study is given. Concepts of probabilistic importance are presented within the fault tree framework and applied to the areas of system design, diagnosis and simulation. The computer code IMPORTANCE ranks basic events and cut sets according to a sensitivity analysis. A useful feature of the IMPORTANCE code is that it can accept relative failure data as input. The output of the IMPORTANCE code can assist an analyst in finding weaknesses in system design and operation, suggest the most optimal course of system upgrade, and determine the optimal location of sensors within a system. A general simulation model of system failure in terms of fault tree logic is described. The model is intended for efficient diagnosis of the causes of system failure in the event of a system breakdown. It can also be used to assist an operator in making decisions under a time constraint regarding the future course of operations. The model is well suited for computer implementation. New results incorporated in the simulation model include an algorithm to generate repair checklists on the basis of fault tree logic and a one-step-ahead optimization procedure that minimizes the expected time to diagnose system failure. (80 figures, 20 tables)

  19. Using Fault Trees to Advance Understanding of Diagnostic Errors.

    Science.gov (United States)

    Rogith, Deevakar; Iyengar, M Sriram; Singh, Hardeep

    2017-11-01

    Diagnostic errors annually affect at least 5% of adults in the outpatient setting in the United States. Formal analytic techniques are only infrequently used to understand them, in part because of the complexity of diagnostic processes and clinical work flows involved. In this article, diagnostic errors were modeled using fault tree analysis (FTA), a form of root cause analysis that has been successfully used in other high-complexity, high-risk contexts. How factors contributing to diagnostic errors can be systematically modeled by FTA to inform error understanding and error prevention is demonstrated. A team of three experts reviewed 10 published cases of diagnostic error and constructed fault trees. The fault trees were modeled according to currently available conceptual frameworks characterizing diagnostic error. The 10 trees were then synthesized into a single fault tree to identify common contributing factors and pathways leading to diagnostic error. FTA is a visual, structured, deductive approach that depicts the temporal sequence of events and their interactions in a formal logical hierarchy. The visual FTA enables easier understanding of causative processes and cognitive and system factors, as well as rapid identification of common pathways and interactions in a unified fashion. In addition, it enables calculation of empirical estimates for causative pathways. Thus, fault trees might provide a useful framework for both quantitative and qualitative analysis of diagnostic errors. Future directions include establishing validity and reliability by modeling a wider range of error cases, conducting quantitative evaluations, and undertaking deeper exploration of other FTA capabilities. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  20. Verification of Fault Tree Models with RBDGG Methodology

    International Nuclear Information System (INIS)

    Kim, Man Cheol

    2010-01-01

    Currently, fault tree analysis is widely used in the field of probabilistic safety assessment (PSA) of nuclear power plants (NPPs). To guarantee the correctness of fault tree models, which are usually manually constructed by analysts, a review by other analysts is widely used for verifying constructed fault tree models. Recently, an extension of the reliability block diagram was developed, which is named as RBDGG (reliability block diagram with general gates). The advantage of the RBDGG methodology is that the structure of a RBDGG model is very similar to the actual structure of the analyzed system and, therefore, the modeling of a system for a system reliability and unavailability analysis becomes very intuitive and easy. The main idea of the development of the RBDGG methodology is similar to that of the development of the RGGG (Reliability Graph with General Gates) methodology. The difference between the RBDGG methodology and RGGG methodology is that the RBDGG methodology focuses on the block failures while the RGGG methodology focuses on the connection line failures. But, it is also known that an RGGG model can be converted to an RBDGG model and vice versa. In this paper, a new method for the verification of the constructed fault tree models using the RBDGG methodology is proposed and demonstrated

  1. A Method to Quantify Plant Availability and Initiating Event Frequency Using a Large Event Tree, Small Fault Tree Model

    International Nuclear Information System (INIS)

    Kee, Ernest J.; Sun, Alice; Rodgers, Shawn; Popova, ElmiraV; Nelson, Paul; Moiseytseva, Vera; Wang, Eric

    2006-01-01

    South Texas Project uses a large fault tree to produce scenarios (minimal cut sets) used in quantification of plant availability and event frequency predictions. On the other hand, the South Texas Project probabilistic risk assessment model uses a large event tree, small fault tree for quantifying core damage and radioactive release frequency predictions. The South Texas Project is converting its availability and event frequency model to use a large event tree, small fault in an effort to streamline application support and to provide additional detail in results. The availability and event frequency model as well as the applications it supports (maintenance and operational risk management, system engineering health assessment, preventive maintenance optimization, and RIAM) are briefly described. A methodology to perform availability modeling in a large event tree, small fault tree framework is described in detail. How the methodology can be used to support South Texas Project maintenance and operations risk management is described in detail. Differences with other fault tree methods and other recently proposed methods are discussed in detail. While the methods described are novel to the South Texas Project Risk Management program and to large event tree, small fault tree models, concepts in the area of application support and availability modeling have wider applicability to the industry. (authors)

  2. Fault diagnosis of power transformer based on fault-tree analysis (FTA)

    Science.gov (United States)

    Wang, Yongliang; Li, Xiaoqiang; Ma, Jianwei; Li, SuoYu

    2017-05-01

    Power transformers is an important equipment in power plants and substations, power distribution transmission link is made an important hub of power systems. Its performance directly affects the quality and health of the power system reliability and stability. This paper summarizes the five parts according to the fault type power transformers, then from the time dimension divided into three stages of power transformer fault, use DGA routine analysis and infrared diagnostics criterion set power transformer running state, finally, according to the needs of power transformer fault diagnosis, by the general to the section by stepwise refinement of dendritic tree constructed power transformer fault

  3. A computer-oriented approach to fault-tree construction. Topical report No. 1

    International Nuclear Information System (INIS)

    Chu, B.B.

    1976-11-01

    Fault Tree Analysis is one of the major tools for the safety and reliability analysis of large systems. A methodology for systematically constructing fault trees for general complex systems is developed and applied, via the computer program CAT, to several systems. First, a means of representing component behavior by decision tables is presented. In order to use these tables, a procedure for constructing and editing fault trees, either manually or by computer, is described. In order to verify the methodology the computer program CAT has been developed and used to construct fault trees for two systems

  4. FTREX Testing Report (Fault Tree Reliability Evaluation eXpert) Version 1.5

    International Nuclear Information System (INIS)

    Jung, Woo Sik

    2009-07-01

    In order to verify FTREX functions and to confirm the correctness of FTREX 1.5, various tests were performed 1.fault trees with negates 2.fault trees with house events 3.fault trees with multiple tops 4.fault trees with logical loops 5.fault trees with initiators, house events, negates, logical loops, and flag events By using the automated cutest propagation test, the FTREX 1.5 functions are verified. FTREX version 1.3 and later versions have capability to perform bottom-up cutset-propagation test in order check cutest status. FTREX 1.5 always generates the proper minimal cut sets. All the output cutsets of the tested problems are MCSs (Minimal Cut Sets) and have no non-minimal cutsets and improper cutsets. The improper cutsets are those that have no effect to top, have multiple initiators, or have disjoint events A * -A

  5. A Weibull-based compositional approach for hierarchical dynamic fault trees

    International Nuclear Information System (INIS)

    Chiacchio, F.; Cacioppo, M.; D'Urso, D.; Manno, G.; Trapani, N.; Compagno, L.

    2013-01-01

    The solution of a dynamic fault tree (DFT) for the reliability assessment can be achieved using a wide variety of techniques. These techniques have a strong theoretical foundation as both the analytical and the simulation methods have been extensively developed. Nevertheless, they all present the same limits that appear with the increasing of the size of the fault trees (i.e., state space explosion, time-consuming simulations), compromising the resolution. We have tested the feasibility of a composition algorithm based on a Weibull distribution, addressed to the resolution of a general class of dynamic fault trees characterized by non-repairable basic events and generally distributed failure times. The proposed composition algorithm is used to generalize the traditional hierarchical technique that, as previous literature have extensively confirmed, is able to reduce the computational effort of a large DFT through the modularization of independent parts of the tree. The results of this study are achieved both through simulation and analytical techniques, thus confirming the capability to solve a quite general class of dynamic fault trees and overcome the limits of traditional techniques.

  6. A comparison between fault tree analysis and reliability graph with general gates

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Seong, Poong Hyun; Jung, Woo Sik

    2004-01-01

    Currently, level-1 probabilistic safety assessment (PSA) is performed on the basis of event tree analysis and fault tree analysis. Kim and Seong developed a new method for system reliability analysis named reliability graph with general gates (RGGG). The RGGG is an extension of conventional reliability graph, and it utilizes the transformation of system structures to equivalent Bayesian networks for quantitative calculation. The RGGG is considered to be intuitive and easy-to-use while as powerful as fault tree analysis. As an example, Kim and Seong already showed that the Bayesian network model for digital plant protection system (DPPS), which is transformed from the RGGG model for DPPS, can be shown in 1 page, while the fault tree model for DPPS consists of 64 pages of fault trees. Kim and Seong also insisted that Bayesian network model for DPPS is more intuitive because the one-to-one matching between each node in the Bayesian network model and an actual component of DPPS is possible. In this paper, we are going to give a comparison between fault tree analysis and the RGGG method with two example systems. The two example systems are the recirculation of in Korean standard nuclear power plants (KSNP) and the fault tree model developed by Rauzy

  7. Component-based modeling of systems for automated fault tree generation

    International Nuclear Information System (INIS)

    Majdara, Aref; Wakabayashi, Toshio

    2009-01-01

    One of the challenges in the field of automated fault tree construction is to find an efficient modeling approach that can support modeling of different types of systems without ignoring any necessary details. In this paper, we are going to represent a new system of modeling approach for computer-aided fault tree generation. In this method, every system model is composed of some components and different types of flows propagating through them. Each component has a function table that describes its input-output relations. For the components having different operational states, there is also a state transition table. Each component can communicate with other components in the system only through its inputs and outputs. A trace-back algorithm is proposed that can be applied to the system model to generate the required fault trees. The system modeling approach and the fault tree construction algorithm are applied to a fire sprinkler system and the results are presented

  8. Treatment of complementary events in event trees in constructing linked fault trees for level 1 and level 2 PRA

    International Nuclear Information System (INIS)

    Jo, Y. G.

    2008-01-01

    Complementary events in the event trees for a PRA model should be treated properly in order to evaluate plant risk correctly. In this study, the characteristics of the following three different cut-set generation methods were investigated first in order to find the best practical way for treating complementary events: 1) exact method which treats complementary events logically, 2) no-delete term method which does not treat complementary events at all, and 3) delete term method which treats complementary events by deleting nonsense cut-sets which are generated as a result of ignoring complementary events. Then, practical methods for treating complementary events in constructing linked fault trees for level 1 and level 2 PRA in EPRI R and R workstation software environment, where CAFTA is the fault tree editor and FORTE is the cut-set engine, were suggested and demonstrated. The suggested methods deal with the following selected four typical cases: Case 1: an event tree event (E) is represented by a fault tree gate whose inputs consist of only fault tree gates, Case 2: E is represented by a single basic event, Case 3: E is represented by an OR fault tree gate which has a single basic event and a fault tree gate as inputs, and Case 4: E is represented by an AND fault tree gate which has a single basic event and a fault tree gate as inputs. In the suggested methods, first the high level logic structures of event tree events are examined and restructured, if needed. Then, the delete term method, the exact method, and the combination of the two methods are applied to Case 1, Case 2, and Cases 3 and 4, respectively. Also, it is recommended to treat complementary events, using the suggested methods, before level 1 and level 2 PRA fault trees are coupled. It should be noted that the selected four typical cases may not cover all different cases encountered in level 1 and level 2 PRA modeling. However, a process similar to the one suggested in this study may be used to find

  9. Utilization of fault tree analysis techniques in fire protection work

    International Nuclear Information System (INIS)

    Crass, E.R.

    1986-01-01

    This paper describes the development of a fault tree model for a typical pressurized water reactor (PWR), and the subsequent use of this model to perform a safe shutdown analysis and determine conformance with Section IIIG of 10 CFR 50, Appendix R. The paper describes the rationale for choosing this analytical tool, the development of the fault tree model, the analysis of the model using the PREP code, disposition of the results, and finally, application of the results to determine the need for plant modifications. It concludes with a review of the strengths and weaknesses of the use of Fault Tree Methodology for this application

  10. An ordering heuristic for building Binary Decision Diagrams for fault-trees

    International Nuclear Information System (INIS)

    Bouissou, M.

    1997-01-01

    Binary Decision Diagrams (BDD) have recently made a noticeable entry in the RAMS field. This kind of representation for boolean functions makes possible the assessment of complex fault-trees, both qualitatively (minimal cut-sets search) and quantitatively (exact calculation of top event probability). The object of the paper is to present a pre-processing of the fault-tree which ensures that the results given by different heuristics on the 'optimized' fault-tree are not too sensitive to the way the tree is written. This property is based on a theoretical proof. In contrast with some well known heuristics, the method proposed is not based only on intuition and practical experiments. (author)

  11. Fault tree synthesis for software design analysis of PLC based safety-critical systems

    International Nuclear Information System (INIS)

    Koo, S. R.; Cho, C. H.; Seong, P. H.

    2006-01-01

    As a software verification and validation should be performed for the development of PLC based safety-critical systems, a software safety analysis is also considered in line with entire software life cycle. In this paper, we propose a technique of software safety analysis in the design phase. Among various software hazard analysis techniques, fault tree analysis is most widely used for the safety analysis of nuclear power plant systems. Fault tree analysis also has the most intuitive notation and makes both qualitative and quantitative analyses possible. To analyze the design phase more effectively, we propose a technique of fault tree synthesis, along with a universal fault tree template for the architecture modules of nuclear software. Consequently, we can analyze the safety of software on the basis of fault tree synthesis. (authors)

  12. Identification of independent modules in fault trees which contain dependent basic events

    International Nuclear Information System (INIS)

    Sun, H.; Andrews, J.D.

    2004-01-01

    The reliability performance of a system is frequently a function of component failures of which some are independent whilst others are interdependent. It is possible to represent the system failure logic in a fault tree diagram, however only the sections containing independent events can be assessed using the conventional fault tree analysis methodology. The analysis of the dependent sections will require a Markov analysis. Since the efficiency of the Markov analysis largely depends on the size of the established Markov model, the key is to extract from the fault tree the smallest sections which contain dependencies. This paper proposes a method aimed at establishing the smallest Markov model for the dependencies contained within the fault tree

  13. Automated fault tree analysis: the GRAFTER system

    International Nuclear Information System (INIS)

    Sancaktar, S.; Sharp, D.R.

    1985-01-01

    An inherent part of probabilistic risk assessment (PRA) is the construction and analysis of detailed fault trees. For this purpose, a fault tree computer graphics code named GRAFTER has been developed. The code system centers around the GRAFTER code. This code is used interactively to construct, store, update and print fault trees of small or large sizes. The SIMON code is used to provide data for the basic event probabilities. ENCODE is used to process the GRAFTER files to prepare input for the WAMCUT code. WAMCUT is used to quantify the top event probability and to identify the cutsets. This code system has been extensively used in various PRA projects. It has resulted in reduced manpower costs, increased QA capability, ease of documentation and it has simplified sensitivity analyses. Because of its automated nature, it is also suitable for LIVING PRA Studies which require updating and modifications during the lifetime of the plant. Brief descriptions and capabilities of the GRAFTER, SIMON and ENCODE codes are provided; an application of the GRAFTER system is outlined; and conclusions and comments on the code system are given

  14. FTA, Fault Tree Analysis for Minimal Cut Sets, Graphics for CALCOMP

    International Nuclear Information System (INIS)

    Van Slyke, W.J.; Griffing, D.E.; Diven, J.

    1978-01-01

    1 - Description of problem or function: The FTA (Fault Tree Analysis) system was designed to predict probabilities of the modes of failure for complex systems and to graphically present the structure of systems. There are three programs in the system. Program ALLCUTS performs the calculations. Program KILMER constructs a CalComp plot file of the system fault tree. Program BRANCH builds a cross-reference list of the system fault tree. 2 - Method of solution: ALLCUTS employs a top-down set expansion algorithm to find fault tree cut-sets and then optionally calculates their probability using a currently accepted cut-set quantification method. The methodology is adapted from that in WASH-1400 (draft), August 1974. 3 - Restrictions on the complexity of the problem: Maxima of: 175 basic events, 425 rate events. ALLCUTS may be expanded to solve larger problems depending on available core memory

  15. A computer code for fault tree calculations: PATREC

    International Nuclear Information System (INIS)

    Blin, A.; Carnino, A.; Koen, B.V.; Duchemin, B.; Lanore, J.M.; Kalli, H.

    1978-01-01

    A computer code for evaluating the reliability of complex system by fault tree is described in this paper. It uses pattern recognition approach and programming techniques from IBM PL1 language. It can take account of many of the present day problems: multi-dependencies treatment, dispersion in the reliability data parameters, influence of common mode failures. The code is running currently since two years now in Commissariat a l'Energie Atomique Saclay center and shall be used in a future extension for automatic fault trees construction

  16. Review: Evaluation of Foot-and-Mouth Disease Control Using Fault Tree Analysis.

    Science.gov (United States)

    Isoda, N; Kadohira, M; Sekiguchi, S; Schuppers, M; Stärk, K D C

    2015-06-01

    An outbreak of foot-and-mouth disease (FMD) causes huge economic losses and animal welfare problems. Although much can be learnt from past FMD outbreaks, several countries are not satisfied with their degree of contingency planning and aiming at more assurance that their control measures will be effective. The purpose of the present article was to develop a generic fault tree framework for the control of an FMD outbreak as a basis for systematic improvement and refinement of control activities and general preparedness. Fault trees are typically used in engineering to document pathways that can lead to an undesired event, that is, ineffective FMD control. The fault tree method allows risk managers to identify immature parts of the control system and to analyse the events or steps that will most probably delay rapid and effective disease control during a real outbreak. The present developed fault tree is generic and can be tailored to fit the specific needs of countries. For instance, the specific fault tree for the 2001 FMD outbreak in the UK was refined based on control weaknesses discussed in peer-reviewed articles. Furthermore, the specific fault tree based on the 2001 outbreak was applied to the subsequent FMD outbreak in 2007 to assess the refinement of control measures following the earlier, major outbreak. The FMD fault tree can assist risk managers to develop more refined and adequate control activities against FMD outbreaks and to find optimum strategies for rapid control. Further application using the current tree will be one of the basic measures for FMD control worldwide. © 2013 Blackwell Verlag GmbH.

  17. Modularization of fault trees: a method to reduce the cost of analysis

    International Nuclear Information System (INIS)

    Chatterjee, P.

    1975-01-01

    The problem of analyzing large fault trees is considered. The concept of the finest modular representation of a fault tree is introduced and an algorithm is presented for finding this representation. The algorithm will also identify trees which cannot be modularized. Applications of such modularizations are discussed

  18. An ordering heuristic for building Binary Decision Diagrams for fault-trees

    Energy Technology Data Exchange (ETDEWEB)

    Bouissou, M. [Electricite de France (EDF), 75 - Paris (France)

    1997-12-31

    Binary Decision Diagrams (BDD) have recently made a noticeable entry in the RAMS field. This kind of representation for boolean functions makes possible the assessment of complex fault-trees, both qualitatively (minimal cut-sets search) and quantitatively (exact calculation of top event probability). The object of the paper is to present a pre-processing of the fault-tree which ensures that the results given by different heuristics on the `optimized` fault-tree are not too sensitive to the way the tree is written. This property is based on a theoretical proof. In contrast with some well known heuristics, the method proposed is not based only on intuition and practical experiments. (author) 12 refs.

  19. HVAC fault tree analysis for WIPP integrated risk assessment

    International Nuclear Information System (INIS)

    Kirby, P.; Iacovino, J.

    1990-01-01

    In order to evaluate the public health risk from operation of the Waste Isolation Pilot Plant (WIPP) due to potential radioactive releases, a probabilistic risk assessment of waste handling operations was conducted. One major aspect of this risk assessment involved fault tree analysis of the plant heating, ventilation, and air conditioning (HVAC) systems, which comprise the final barrier between waste handling operations and the environment. 1 refs., 1 tab

  20. An enhanced component connection method for conversion of fault trees to binary decision diagrams

    International Nuclear Information System (INIS)

    Remenyte-Prescott, R.; Andrews, J.D.

    2008-01-01

    Fault tree analysis (FTA) is widely applied to assess the failure probability of industrial systems. Many computer packages are available, which are based on conventional kinetic tree theory methods. When dealing with large (possibly non-coherent) fault trees, the limitations of the technique in terms of accuracy of the solutions and the efficiency of the processing time become apparent. Over recent years, the binary decision diagram (BDD) method has been developed that solves fault trees and overcomes the disadvantages of the conventional FTA approach. First of all, a fault tree for a particular system failure mode is constructed and then converted to a BDD for analysis. This paper analyses alternative methods for the fault tree to BDD conversion process. For most fault tree to BDD conversion approaches, the basic events of the fault tree are placed in an ordering. This can dramatically affect the size of the final BDD and the success of qualitative and quantitative analyses of the system. A set of rules is then applied to each gate in the fault tree to generate the BDD. An alternative approach can also be used, where BDD constructs for each of the gate types are first built and then merged to represent a parent gate. A powerful and efficient property, sub-node sharing, is also incorporated in the enhanced method proposed in this paper. Finally, a combined approach is developed taking the best features of the alternative methods. The efficiency of the techniques is analysed and discussed

  1. NuFTA: A CASE Tool for Automatic Software Fault Tree Analysis

    International Nuclear Information System (INIS)

    Yun, Sang Hyun; Lee, Dong Ah; Yoo, Jun Beom

    2010-01-01

    Software fault tree analysis (SFTA) is widely used for analyzing software requiring high-reliability. In SFTA, experts predict failures of system through HA-ZOP (Hazard and Operability study) or FMEA (Failure Mode and Effects Analysis) and draw software fault trees about the failures. Quality and cost of the software fault tree, therefore, depend on knowledge and experience of the experts. This paper proposes a CASE tool NuFTA in order to assist experts of safety analysis. The NuFTA automatically generate software fault trees from NuSCR formal requirements specification. NuSCR is a formal specification language used for specifying software requirements of KNICS RPS (Reactor Protection System) in Korea. We used the SFTA templates proposed by in order to generate SFTA automatically. The NuFTA also generates logical formulae summarizing the failure's cause, and we have a plan to use the formulae usefully through formal verification techniques

  2. Process plant alarm diagnosis using synthesised fault tree knowledge

    International Nuclear Information System (INIS)

    Trenchard, A.J.

    1990-01-01

    The development of computer based tools, to assist process plant operators in their task of fault/alarm diagnosis, has received much attention over the last twenty five years. More recently, with the emergence of Artificial Intelligence (AI) technology, the research activity in this subject area has heightened. As a result, there are a great variety of fault diagnosis methodologies, using many different approaches to represent the fault propagation behaviour of process plant. These range in complexity from steady state quantitative models to more abstract definitions of the relationships between process alarms. Unfortunately, very few of the techniques have been tried and tested on process plant and even fewer have been judged to be commercial successes. One of the outstanding problems still remains the time and effort required to understand and model the fault propagation behaviour of each considered process. This thesis describes the development of an experimental knowledge based system (KBS) to diagnose process plant faults, as indicated by process variable alarms. In an attempt to minimise the modelling effort, the KBS has been designed to infer diagnoses using a fault tree representation of the process behaviour, generated using an existing fault tree synthesis package (FAULTFINDER). The process is described to FAULTFINDER as a configuration of unit models, derived from a standard model library or by tailoring existing models. The resultant alarm diagnosis methodology appears to work well for hard (non-rectifying) faults, but is likely to be less robust when attempting to diagnose intermittent faults and transient behaviour. The synthesised fault trees were found to contain the bulk of the information required for the diagnostic task, however, this needed to be augmented with extra information in certain circumstances. (author)

  3. DG TO FT - AUTOMATIC TRANSLATION OF DIGRAPH TO FAULT TREE MODELS

    Science.gov (United States)

    Iverson, D. L.

    1994-01-01

    Fault tree and digraph models are frequently used for system failure analysis. Both types of models represent a failure space view of the system using AND and OR nodes in a directed graph structure. Each model has its advantages. While digraphs can be derived in a fairly straightforward manner from system schematics and knowledge about component failure modes and system design, fault tree structure allows for fast processing using efficient techniques developed for tree data structures. The similarities between digraphs and fault trees permits the information encoded in the digraph to be translated into a logically equivalent fault tree. The DG TO FT translation tool will automatically translate digraph models, including those with loops or cycles, into fault tree models that have the same minimum cut set solutions as the input digraph. This tool could be useful, for example, if some parts of a system have been modeled using digraphs and others using fault trees. The digraphs could be translated and incorporated into the fault trees, allowing them to be analyzed using a number of powerful fault tree processing codes, such as cut set and quantitative solution codes. A cut set for a given node is a group of failure events that will cause the failure of the node. A minimum cut set for a node is any cut set that, if any of the failures in the set were to be removed, the occurrence of the other failures in the set will not cause the failure of the event represented by the node. Cut sets calculations can be used to find dependencies, weak links, and vital system components whose failures would cause serious systems failure. The DG TO FT translation system reads in a digraph with each node listed as a separate object in the input file. The user specifies a terminal node for the digraph that will be used as the top node of the resulting fault tree. A fault tree basic event node representing the failure of that digraph node is created and becomes a child of the terminal

  4. PREP KITT, System Reliability by Fault Tree Analysis. PREP, Min Path Set and Min Cut Set for Fault Tree Analysis, Monte-Carlo Method. KITT, Component and System Reliability Information from Kinetic Fault Tree Theory

    International Nuclear Information System (INIS)

    Vesely, W.E.; Narum, R.E.

    1997-01-01

    1 - Description of problem or function: The PREP/KITT computer program package obtains system reliability information from a system fault tree. The PREP program finds the minimal cut sets and/or the minimal path sets of the system fault tree. (A minimal cut set is a smallest set of components such that if all the components are simultaneously failed the system is failed. A minimal path set is a smallest set of components such that if all of the components are simultaneously functioning the system is functioning.) The KITT programs determine reliability information for the components of each minimal cut or path set, for each minimal cut or path set, and for the system. Exact, time-dependent reliability information is determined for each component and for each minimal cut set or path set. For the system, reliability results are obtained by upper bound approximations or by a bracketing procedure in which various upper and lower bounds may be obtained as close to one another as desired. The KITT programs can handle independent components which are non-repairable or which have a constant repair time. Any assortment of non-repairable components and components having constant repair times can be considered. Any inhibit conditions having constant probabilities of occurrence can be handled. The failure intensity of each component is assumed to be constant with respect to time. The KITT2 program can also handle components which during different time intervals, called phases, may have different reliability properties. 2 - Method of solution: The PREP program obtains minimal cut sets by either direct deterministic testing or by an efficient Monte Carlo algorithm. The minimal path sets are obtained using the Monte Carlo algorithm. The reliability information is obtained by the KITT programs from numerical solution of the simple integral balance equations of kinetic tree theory. 3 - Restrictions on the complexity of the problem: The PREP program will obtain the minimal cut and

  5. Interim reliability evaluation program, Browns Ferry fault trees

    International Nuclear Information System (INIS)

    Stewart, M.E.

    1981-01-01

    An abbreviated fault tree method is used to evaluate and model Browns Ferry systems in the Interim Reliability Evaluation programs, simplifying the recording and displaying of events, yet maintaining the system of identifying faults. The level of investigation is not changed. The analytical thought process inherent in the conventional method is not compromised. But the abbreviated method takes less time, and the fault modes are much more visible

  6. Generalized fault tree analysis combined with state analysis

    International Nuclear Information System (INIS)

    Caldarola, L.

    1980-02-01

    An analytical theory has been developed which allows one to calculate the occurrence probability of the top event of a fault tree with multistate (two or more than two states) components. It is shown that, in order to correctly describe a system with multistate components, a special type of boolean algebra is required. This is called 'boolean algebra with restrictions on variables' and its basic rules are the same as those of the traditional boolean algebra with some additional restrictions on the variables. These restrictions are extensively discussed in the paper. It is also shown that the boolean algebra with restrictions on variables facilitates the task of formally combining fault tree analysis with state analysis. The computer program MUSTAFA 1 based on the above theory has been developed. It can analyse fault trees of system containing statistically independent as well as dependent components with two or more than two states. MUSTAFA 1 can handle coherent as well as non coherent boolean functions. (orig.) 891 HP/orig. 892 MB [de

  7. Fuzzy Uncertainty Evaluation for Fault Tree Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Beom; Shim, Hyung Jin [Seoul National University, Seoul (Korea, Republic of); Jae, Moo Sung [Hanyang University, Seoul (Korea, Republic of)

    2015-05-15

    This traditional probabilistic approach can calculate relatively accurate results. However it requires a long time because of repetitive computation due to the MC method. In addition, when informative data for statistical analysis are not sufficient or some events are mainly caused by human error, the probabilistic approach may not be possible because uncertainties of these events are difficult to be expressed by probabilistic distributions. In order to reduce the computation time and quantify uncertainties of top events when basic events whose uncertainties are difficult to be expressed by probabilistic distributions exist, the fuzzy uncertainty propagation based on fuzzy set theory can be applied. In this paper, we develop a fuzzy uncertainty propagation code and apply the fault tree of the core damage accident after the large loss of coolant accident (LLOCA). The fuzzy uncertainty propagation code is implemented and tested for the fault tree of the radiation release accident. We apply this code to the fault tree of the core damage accident after the LLOCA in three cases and compare the results with those computed by the probabilistic uncertainty propagation using the MC method. The results obtained by the fuzzy uncertainty propagation can be calculated in relatively short time, covering the results obtained by the probabilistic uncertainty propagation.

  8. Modular techniques for dynamic fault-tree analysis

    Science.gov (United States)

    Patterson-Hine, F. A.; Dugan, Joanne B.

    1992-01-01

    It is noted that current approaches used to assess the dependability of complex systems such as Space Station Freedom and the Air Traffic Control System are incapable of handling the size and complexity of these highly integrated designs. A novel technique for modeling such systems which is built upon current techniques in Markov theory and combinatorial analysis is described. It enables the development of a hierarchical representation of system behavior which is more flexible than either technique alone. A solution strategy which is based on an object-oriented approach to model representation and evaluation is discussed. The technique is virtually transparent to the user since the fault tree models can be built graphically and the objects defined automatically. The tree modularization procedure allows the two model types, Markov and combinatoric, to coexist and does not require that the entire fault tree be translated to a Markov chain for evaluation. This effectively reduces the size of the Markov chain required and enables solutions with less truncation, making analysis of longer mission times possible. Using the fault-tolerant parallel processor as an example, a model is built and solved for a specific mission scenario and the solution approach is illustrated in detail.

  9. On the use of non-coherent fault trees in safety and security studies

    International Nuclear Information System (INIS)

    Contini, S.; Cojazzi, G.G.M.; Renda, G.

    2008-01-01

    This paper gives some insights on the usefulness of non-coherent fault trees in system modelling from both the point of view of safety and security. A safety-related system can evolve from the working states to failed states through degraded states, i.e. working state, but in a degraded mode. In practical applications the degraded states may be of particular interest due e.g. to the associated risk increase or the different types of consequent actions. The top events definitions of such states contain the working conditions of some sub-systems/components. How the use of non-coherent fault trees can greatly simplify both the modelling and quantification of these states is shown in this paper. Some considerations about the interpretation of the importance indexes of negated basic events are also briefly described. When dealing with security applications, there is a need to cope not only with stochastic events, such as component failures and human errors, but also with deliberate intentional actions, whose successes might be characterised by high probability values. Different mutually exclusive attack scenarios may be envisaged for a given system. Hence, the essential feature of a fault tree analyser is the capability to determine the exact value of the top event probability containing mutually exclusive events. It is also shown that in these cases the use of non-coherent fault trees allows solving the problem with limited effort

  10. Computer aided fault tree synthesis

    International Nuclear Information System (INIS)

    Poucet, A.

    1983-01-01

    Nuclear as well as non-nuclear organisations are showing during the past few years a growing interest in the field of reliability analysis. This urges for the development of powerful, state of the art methods and computer codes for performing such analysis on complex systems. In this report an interactive, computer aided approach is discussed, based on the well known fault tree technique. The time consuming and difficut task of manually constructing a system model (one or more fault trees) is replaced by an efficient interactive procedure in which the flexibility and the learning process inherent to the manual approach are combined with the accuracy in the modelling and the speed of the fully automatical approach. The method presented is based upon the use of a library containing component models. The possibility of setting up a standard library of models of general use and the link with a data collection system are discussed. The method has been implemented in the CAFTS-SALP software package which is described shortly in the report

  11. Probabilistic risk assessment course documentation. Volume 4. System reliability and analysis techniques sessions B/C - event trees/fault trees

    International Nuclear Information System (INIS)

    Haasl, D.; Young, J.

    1985-08-01

    This course will employ a combination of lecture material and practical problem solving in order to develop competence and understanding of th principles and techniques of event tree and fault tree analysis. The role of these techniques in the overall context of PRA will be described. The emphasis of this course will be on the basic, traditional methods of event tree and fault tree analysis

  12. Study on the scope of fault tree method applicability

    International Nuclear Information System (INIS)

    Ito, Taiju

    1980-03-01

    In fault tree analysis of the reliability of nuclear safety system, including reliability analysis of nuclear protection system, there seem to be some documents in which application of the fault tree method is unreasonable. In fault tree method, the addition rule and the multiplication rule are usually used. The addition rule and the multiplication rule must hold exactly or at least practically. The addition rule has no problem but the multiplication rule has occasionally some problem. For unreliability, mean unavailability and instantaneous unavailability of the elements, holding or not of the multiplication rule has been studied comprehensively. Between the unreliability of each element without maintenance, the multiplication rule holds. Between the instantaneous unavailability of each element, with maintenance or not, the multiplication rule also holds. Between the unreliability of each subsystem with maintenance, however, the multiplication rule does not hold, because the product value is larger than the value of unreliability for a parallel system consisting of the two subsystems with maintenance. Between the mean unavailability of each element without maintenance, the multiplication rule also does not hold, because the product value is smaller than the value of mean unavailability for a parallel system consisting of the two elements without maintenance. In these cases, therefore, the fault tree method may not be applied by rote for reliability analysis of the system. (author)

  13. Application of Fault Tree Analysis and Fuzzy Neural Networks to Fault Diagnosis in the Internet of Things (IoT) for Aquaculture.

    Science.gov (United States)

    Chen, Yingyi; Zhen, Zhumi; Yu, Huihui; Xu, Jing

    2017-01-14

    In the Internet of Things (IoT) equipment used for aquaculture is often deployed in outdoor ponds located in remote areas. Faults occur frequently in these tough environments and the staff generally lack professional knowledge and pay a low degree of attention in these areas. Once faults happen, expert personnel must carry out maintenance outdoors. Therefore, this study presents an intelligent method for fault diagnosis based on fault tree analysis and a fuzzy neural network. In the proposed method, first, the fault tree presents a logic structure of fault symptoms and faults. Second, rules extracted from the fault trees avoid duplicate and redundancy. Third, the fuzzy neural network is applied to train the relationship mapping between fault symptoms and faults. In the aquaculture IoT, one fault can cause various fault symptoms, and one symptom can be caused by a variety of faults. Four fault relationships are obtained. Results show that one symptom-to-one fault, two symptoms-to-two faults, and two symptoms-to-one fault relationships can be rapidly diagnosed with high precision, while one symptom-to-two faults patterns perform not so well, but are still worth researching. This model implements diagnosis for most kinds of faults in the aquaculture IoT.

  14. Application of Fault Tree Analysis and Fuzzy Neural Networks to Fault Diagnosis in the Internet of Things (IoT for Aquaculture

    Directory of Open Access Journals (Sweden)

    Yingyi Chen

    2017-01-01

    Full Text Available In the Internet of Things (IoT equipment used for aquaculture is often deployed in outdoor ponds located in remote areas. Faults occur frequently in these tough environments and the staff generally lack professional knowledge and pay a low degree of attention in these areas. Once faults happen, expert personnel must carry out maintenance outdoors. Therefore, this study presents an intelligent method for fault diagnosis based on fault tree analysis and a fuzzy neural network. In the proposed method, first, the fault tree presents a logic structure of fault symptoms and faults. Second, rules extracted from the fault trees avoid duplicate and redundancy. Third, the fuzzy neural network is applied to train the relationship mapping between fault symptoms and faults. In the aquaculture IoT, one fault can cause various fault symptoms, and one symptom can be caused by a variety of faults. Four fault relationships are obtained. Results show that one symptom-to-one fault, two symptoms-to-two faults, and two symptoms-to-one fault relationships can be rapidly diagnosed with high precision, while one symptom-to-two faults patterns perform not so well, but are still worth researching. This model implements diagnosis for most kinds of faults in the aquaculture IoT.

  15. Approximate dynamic fault tree calculations for modelling water supply risks

    International Nuclear Information System (INIS)

    Lindhe, Andreas; Norberg, Tommy; Rosén, Lars

    2012-01-01

    Traditional fault tree analysis is not always sufficient when analysing complex systems. To overcome the limitations dynamic fault tree (DFT) analysis is suggested in the literature as well as different approaches for how to solve DFTs. For added value in fault tree analysis, approximate DFT calculations based on a Markovian approach are presented and evaluated here. The approximate DFT calculations are performed using standard Monte Carlo simulations and do not require simulations of the full Markov models, which simplifies model building and in particular calculations. It is shown how to extend the calculations of the traditional OR- and AND-gates, so that information is available on the failure probability, the failure rate and the mean downtime at all levels in the fault tree. Two additional logic gates are presented that make it possible to model a system's ability to compensate for failures. This work was initiated to enable correct analyses of water supply risks. Drinking water systems are typically complex with an inherent ability to compensate for failures that is not easily modelled using traditional logic gates. The approximate DFT calculations are compared to results from simulations of the corresponding Markov models for three water supply examples. For the traditional OR- and AND-gates, and one gate modelling compensation, the errors in the results are small. For the other gate modelling compensation, the error increases with the number of compensating components. The errors are, however, in most cases acceptable with respect to uncertainties in input data. The approximate DFT calculations improve the capabilities of fault tree analysis of drinking water systems since they provide additional and important information and are simple and practically applicable.

  16. The boolean algebra with restricted variables as a tool for fault tree modularization

    International Nuclear Information System (INIS)

    Caldarola, L.; Wickenhaeuser, A.

    1981-08-01

    The number of minimal cut sets (m.c.s.) of very complex and highly interconnected fault trees can become extremely large (e.g. more than 10 7 ). In this case the usual analytical approach of dissecting the fault tree TOP variable into m.c.s. is not only computationally prohibitively expensive, but also meaningless because it does not offer any synthetic overview of system behavior. The method proposed in this paper overcomes the deficiencies of the analytical method. It is shown that, by applying boolean algebra with restricted variables (b.a.w.r.v.), the concept of fault tree modularization can be straightforwardly extended from a single gate to a set of gates. Thus, large fault trees are divided into smaller fault trees (modules), which are connected to each other according to a simple scheme. This scheme is represented by a block diagram in which each block is a module. The modules are analyzed separately by the m.c.s. method, and the results are combined according of the TOP event. The method allows the calculation of very large fault trees in a short time and offers a synthetic overview of systems behavior through the block diagram. Numerical examples are also included. Calculations have been carried out by using the computer code MUSTAMO, which is based on the theory developed in this paper. (orig.) [de

  17. Fault tree analysis for reactor systems

    International Nuclear Information System (INIS)

    Crosetti, P.A.

    1971-01-01

    Reliability analysis is playing an increasingly important role in quantitative assessment of system performance for assuring nuclear safety, improving plant performance and plant life, and reducing plant operating costs. The complexity of today's nuclear plants warrant the use of techniques which will provide a comprehensive evaluation of systems in their total context. In particular, fault tree analysis with probability evaluation can play a key role in assuring nuclear safety, in improving plant performance and plant life, and in reducing plant operating costs. The technique provides an all inclusive, versatile mathematical tool for analyzing complex systems. Its application can include a complete plant as well as any of the systems and subsystems. Fault tree analysis provides an objective basis for analyzing system design, performing trade-off studies, analyzing common mode failures, demonstrating compliance with AEC requirements, and justifying system changes or additions. The logic of the approach makes it readily understandable and, therefore, it serves as an effective visibility tool for both engineering and management. (U.S.)

  18. An investigation of the relations between fault tree analysis and cause consequence analysis with special reference to a photometry and conductimetry system

    International Nuclear Information System (INIS)

    Weber, G.

    1980-02-01

    For an automated photometry and conductimetry system, the relations between cause consequence analysis and fault tree analysis have been investigated. It has been shown how failure combinations of a cause consequence diagram and minimal cuts of a fault tree can be identified. This procedure allows a mutual control of fault tree analysis and cause consequence analysis. From a representation of all failure combinations of the system by means of a matrix we obtain a control of our analysis. Moreover, heuristic rules improving and simplifying the cause consequence analysis can be found. Necessary assumptions for the validity of these rules are discussed. Methodologically, the relation of a fault tree and a cause consequence diagram can be represented (under certain conditions) as a relation of a Boolean function and a binary decision tree. (orig.) 891 HP/orig. 892 MKO [de

  19. Treatment of complementary events in constructing the linked Level 1 and Level 2 fault trees

    International Nuclear Information System (INIS)

    Jo, Young G.; Ahn, Kwang-Il

    2009-01-01

    Complementary events in the event trees for a PRA model should be treated properly in order to evaluate plant risk correctly. In this paper, the characteristics of the following three different cutset generation methods were investigated first in order to find the best practical way for treating complementary events: (1) exact method which treats complementary events logically, (2) no-delete term method which does not treat complementary events at all, and (3) delete term method which treats complementary events by deleting nonsense cutsets which are generated as a result of ignoring complementary events. Then, practical methods for treating complementary events in constructing linked fault trees for Level 1 and Level 2 PRA were suggested and demonstrated. The suggested methods deal with the following selected four typical cases: (1) Case 1-an event tree event (E) is represented by a fault tree gate whose inputs consist of only fault tree gates, (2) Case 2-E is represented by a single basic event, (3) Case 3-E is represented by an OR fault tree gate which has a single basic event and a fault tree gate as inputs, and (4) Case 4-E is represented by an AND fault tree gate which has a single basic event and a fault tree gate as inputs. In the suggested methods, first the high level logic structures of event tree events are examined and restructured, if needed. Then, the delete term method, the exact method, and the combination of the two methods are applied to through Case 1 to Case 4, respectively. As a result, it is recommended to treat complementary events, using the suggested methods, before Level 1 and Level 2 PRA fault trees are coupled

  20. An Algorithm for Fault-Tree Construction

    DEFF Research Database (Denmark)

    Taylor, J. R.

    1982-01-01

    An algorithm for performing certain parts of the fault tree construction process is described. Its input is a flow sheet of the plant, a piping and instrumentation diagram, or a wiring diagram of the circuits, to be analysed, together with a standard library of component functional and failure...

  1. Improvement of testing and maintenance based on fault tree analysis

    International Nuclear Information System (INIS)

    Cepin, M.

    2000-01-01

    Testing and maintenance of safety equipment is an important issue, which significantly contributes to safe and efficient operation of a nuclear power plant. In this paper a method, which extends the classical fault tree with time, is presented. Its mathematical model is represented by a set of equations, which include time requirements defined in the house event matrix. House events matrix is a representation of house events switched on and off through the discrete points of time. It includes house events, which timely switch on and off parts of the fault tree in accordance with the status of the plant configuration. Time dependent top event probability is calculated by the fault tree evaluations. Arrangement of components outages is determined on base of minimization of mean system unavailability. The results show that application of the method may improve the time placement of testing and maintenance activities of safety equipment. (author)

  2. Fault tree analysis for urban flooding

    NARCIS (Netherlands)

    Ten Veldhuis, J.A.E.; Clemens, F.H.L.R.; Van Gelder, P.H.A.J.M.

    2008-01-01

    Traditional methods to evaluate flood risk mostly focus on storm events as the main cause of flooding. Fault tree analysis is a technique that is able to model all potential causes of flooding and to quantify both the overall probability of flooding and the contributions of all causes of flooding to

  3. Bayesian updating of reliability of civil infrastructure facilities based on condition-state data and fault-tree model

    International Nuclear Information System (INIS)

    Ching Jianye; Leu, S.-S.

    2009-01-01

    This paper considers a difficult but practical circumstance of civil infrastructure management-deterioration/failure data of the infrastructure system are absent while only condition-state data of its components are available. The goal is to develop a framework for estimating time-varying reliabilities of civil infrastructure facilities under such a circumstance. A novel method of analyzing time-varying condition-state data that only reports operational/non-operational status of the components is proposed to update the reliabilities of civil infrastructure facilities. The proposed method assumes that the degradation arrivals can be modeled as a Poisson process with unknown time-varying arrival rate and damage impact and that the target system can be represented as a fault-tree model. To accommodate large uncertainties, a Bayesian algorithm is proposed, and the reliability of the infrastructure system can be quickly updated based on the condition-state data. Use of the new method is demonstrated with a real-world example of hydraulic spillway gate system.

  4. Algorithms and programs for consequence diagram and fault tree construction

    International Nuclear Information System (INIS)

    Hollo, E.; Taylor, J.R.

    1976-12-01

    A presentation of algorithms and programs for consequence diagram and sequential fault tree construction that are intended for reliability and disturbance analysis of large systems. The system to be analyzed must be given as a block diagram formed by mini fault trees of individual system components. The programs were written in LISP programming language and run on a PDP8 computer with 8k words of storage. A description is given of the methods used and of the program construction and working. (author)

  5. Realization of multi-parameter and multi-state in fault tree computer-aided building software

    International Nuclear Information System (INIS)

    Guo Xiaoli; Tong Jiejuan; Xue Dazhi

    2004-01-01

    More than one parameter and more than one failed state of a parameter are often involved in building fault tree, so it is necessary for fault tree computer-aided building software to deal with multi-parameter and multi-state. Fault Tree Expert System (FTES) has the target of aiding the FT-building work of hydraulic systems. This paper expatiates on how to realize multi-parameter and multi-state in FTES with focus on Knowledge Base and Illation Engine. (author)

  6. Seismic Margin Assessment for Research Reactor using Fragility based Fault Tree Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwag, Shinyoung; Oh, Jinho; Lee, Jong-Min; Ryu, Jeong-Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The research reactor has been often subjected to external hazards during the design lifetime. Especially, a seismic event can be one of significant threats to the failure of structure system of the research reactor. This failure is possibly extended to the direct core damage of the reactor. For this purpose, the fault tree for structural system failure leading to the core damage under an earthquake accident is developed. The failure probabilities of basic events are evaluated as fragility curves of log-normal distributions. Finally, the plant-level seismic margin is investigated by the fault tree analysis combining with fragility data and the critical path is identified. The plant-level probabilistic seismic margin assessment using the fragility based fault tree analysis was performed for quantifying the safety of research reactor to a seismic hazard. For this, the fault tree for structural system failure leading to the core damage of the reactor under a seismic accident was developed. The failure probabilities of basic events were evaluated as fragility curves of log-normal distributions.

  7. Fault tree analysis with multistate components

    International Nuclear Information System (INIS)

    Caldarola, L.

    1979-02-01

    A general analytical theory has been developed which allows one to calculate the occurence probability of the top event of a fault tree with multistate (more than states) components. It is shown that, in order to correctly describe a system with multistate components, a special type of Boolean algebra is required. This is called 'Boolean algebra with restrictions on varibales' and its basic rules are the same as those of the traditional Boolean algebra with some additional restrictions on the variables. These restrictions are extensively discussed in the paper. Important features of the method are the identification of the complete base and of the smallest irredundant base of a Boolean function which does not necessarily need to be coherent. It is shown that the identification of the complete base of a Boolean function requires the application of some algorithms which are not used in today's computer programmes for fault tree analysis. The problem of statistical dependence among primary components is discussed. The paper includes a small demonstrative example to illustrate the method. The example includes also statistical dependent components. (orig.) [de

  8. Workflow Fault Tree Generation Through Model Checking

    DEFF Research Database (Denmark)

    Herbert, Luke Thomas; Sharp, Robin

    2014-01-01

    We present a framework for the automated generation of fault trees from models of realworld process workflows, expressed in a formalised subset of the popular Business Process Modelling and Notation (BPMN) language. To capture uncertainty and unreliability in workflows, we extend this formalism...

  9. ANCON: A code for the evaluation of complex fault trees in personal computers

    International Nuclear Information System (INIS)

    Napoles, J.G.; Salomon, J.; Rivero, J.

    1990-01-01

    Performing probabilistic safety analysis has been recognized worldwide as one of the more effective ways for further enhancing safety of Nuclear Power Plants. The evaluation of fault trees plays a fundamental role in these analysis. Some existing limitations in RAM and execution speed of personal computers (PC) has restricted so far their use in the analysis of complex fault trees. Starting from new approaches in the data structure and other possibilities the ANCON code can evaluate complex fault trees in a PC, allowing the user to do a more comprehensive analysis of the considered system in reduced computing time

  10. Rare event simulation for dynamic fault trees

    NARCIS (Netherlands)

    Ruijters, Enno Jozef Johannes; Reijsbergen, D.P.; de Boer, Pieter-Tjerk; Stoelinga, Mariëlle Ida Antoinette

    2017-01-01

    Fault trees (FT) are a popular industrial method for reliability engineering, for which Monte Carlo simulation is an important technique to estimate common dependability metrics, such as the system reliability and availability. A severe drawback of Monte Carlo simulation is that the number of

  11. Rare Event Simulation for Dynamic Fault Trees

    NARCIS (Netherlands)

    Ruijters, Enno Jozef Johannes; Reijsbergen, D.P.; de Boer, Pieter-Tjerk; Stoelinga, Mariëlle Ida Antoinette; Tonetta, Stefano; Schoitsch, Erwin; Bitsch, Friedemann

    2017-01-01

    Fault trees (FT) are a popular industrial method for reliability engineering, for which Monte Carlo simulation is an important technique to estimate common dependability metrics, such as the system reliability and availability. A severe drawback of Monte Carlo simulation is that the number of

  12. Integrated system fault diagnostics utilising digraph and fault tree-based approaches

    International Nuclear Information System (INIS)

    Bartlett, L.M.; Hurdle, E.E.; Kelly, E.M.

    2009-01-01

    With the growing intolerance to failures within systems, the issue of fault diagnosis has become ever prevalent. Information concerning these possible failures can help to minimise the disruption to the functionality of the system by allowing quick rectification. Traditional approaches to fault diagnosis within engineering systems have focused on sequential testing procedures and real-time mechanisms. Both methods have been predominantly limited to single fault causes. Latest approaches also consider the issue of multiple faults in reflection to the characteristics of modern day systems designed for high reliability. In addition, a diagnostic capability is required in real time and for changeable system functionality. This paper focuses on two approaches which have been developed to cater for the demands of diagnosis within current engineering systems, namely application of the fault tree analysis technique and the method of digraphs. Both use a comparative approach to consider differences between actual system behaviour and that expected. The procedural guidelines are discussed for each method, with an experimental aircraft fuel system used to test and demonstrate the features of the techniques. The effectiveness of the approaches is compared and their future potential highlighted

  13. Fault Tree Analysis for an Inspection Robot in a Nuclear Power Plant

    Science.gov (United States)

    Ferguson, Thomas A.; Lu, Lixuan

    2017-09-01

    The life extension of current nuclear reactors has led to an increasing demand on inspection and maintenance of critical reactor components that are too expensive to replace. To reduce the exposure dosage to workers, robotics have become an attractive alternative as a preventative safety tool in nuclear power plants. It is crucial to understand the reliability of these robots in order to increase the veracity and confidence of their results. This study presents the Fault Tree (FT) analysis to a coolant outlet piper snake-arm inspection robot in a nuclear power plant. Fault trees were constructed for a qualitative analysis to determine the reliability of the robot. Insight on the applicability of fault tree methods for inspection robotics in the nuclear industry is gained through this investigation.

  14. Reliability Analysis of Operation for Cableways by FTA (Fault Tree Analysis Method

    Directory of Open Access Journals (Sweden)

    Sergej Težak

    2010-05-01

    Full Text Available This paper examines the reliability of the operation of cableway systems in Slovenia, which has major impact on the quality of service in the mountain tourism, mainly in wintertime. Different types of cableway installations in Slovenia were captured in a sample and fault tree analysis (FTA was made on the basis of the obtained data. The paper presents the results of the analysis. With these results it is possible to determine the probability of faults of different types of cableways, which types of faults have the greatest impact on the termination of operation, which components of cableways fail most, what is the impact of age of cableways on the occurrence of the faults. Finally, an attempt was made to find if occurrence of faults on individual cableway installation has also impact on traffic on this cableway due to reduced quality of service. KEYWORDS: cableways, aerial ropeways, chairlifts, ski-tows, quality, faults, fault tree analysis, reliability, service quality, winter tourism, mountain tourist centre

  15. Fault-Tree Modeling of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hun; Kang, Hyun Gook [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    To achieve technical self-reliance for nuclear I and C systems in Korea, the Advanced Power Reactor 1400 (APR-1400) man-machine interface system (MMIS) architecture was developed by the Korea Atomic Energy Research Institute (KAERI). As one of the systems in the developed MMIS architecture, the Engineered Safety Feature-Component Control System (ESF-CCS) employs a network communication system for the transmission of safety-critical information from group controllers (GCs) to loop controllers (LCs) to effectively accommodate the vast number of field controllers. The developed fault-tree model was then applied to several case studies. As an example of the development of a fault-tree model for ESF-CCS signal failure, the fault-tree model of ESF-CCS signal failure for CS pump PP01A in the CSAS condition was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. The quantitative results for four case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributes up to 1.88% of the probability of ESF-CCS signal failure for the CS pump considered in the case studies.

  16. Systems analysis approach to probabilistic modeling of fault trees

    International Nuclear Information System (INIS)

    Bartholomew, R.J.; Qualls, C.R.

    1985-01-01

    A method of probabilistic modeling of fault tree logic combined with stochastic process theory (Markov modeling) has been developed. Systems are then quantitatively analyzed probabilistically in terms of their failure mechanisms including common cause/common mode effects and time dependent failure and/or repair rate effects that include synergistic and propagational mechanisms. The modeling procedure results in a state vector set of first order, linear, inhomogeneous, differential equations describing the time dependent probabilities of failure described by the fault tree. The solutions of this Failure Mode State Variable (FMSV) model are cumulative probability distribution functions of the system. A method of appropriate synthesis of subsystems to form larger systems is developed and applied to practical nuclear power safety systems

  17. System Analysis by Mapping a Fault-tree into a Bayesian-network

    Science.gov (United States)

    Sheng, B.; Deng, C.; Wang, Y. H.; Tang, L. H.

    2018-05-01

    In view of the limitations of fault tree analysis in reliability assessment, Bayesian Network (BN) has been studied as an alternative technology. After a brief introduction to the method for mapping a Fault Tree (FT) into an equivalent BN, equations used to calculate the structure importance degree, the probability importance degree and the critical importance degree are presented. Furthermore, the correctness of these equations is proved mathematically. Combining with an aircraft landing gear’s FT, an equivalent BN is developed and analysed. The results show that richer and more accurate information have been achieved through the BN method than the FT, which demonstrates that the BN is a superior technique in both reliability assessment and fault diagnosis.

  18. Mode automata and their compilation into fault trees

    International Nuclear Information System (INIS)

    Rauzy, Antoine

    2002-01-01

    In this article, we advocate the use of mode automata as a high level representation language for reliability studies. Mode automata are states/transitions based representations with the additional notion of flow. They can be seen as a generalization of both finite capacity Petri nets and block diagrams. They can be assembled into hierarchies by means of composition operations. The contribution of this article is twofold. First, we introduce mode automata and we discuss their relationship with other formalisms. Second, we propose an algorithm to compile mode automata into Boolean equations (fault trees). Such a compilation is of interest for two reasons. First, assessment tools for Boolean models are much more efficient than those for states/transitions models. Second, the automated generation of fault trees from higher level representations makes easier their maintenance through the life cycle of systems under study

  19. Diagnosis of Constant Faults in Read-Once Contact Networks over Finite Bases using Decision Trees

    KAUST Repository

    Busbait, Monther I.

    2014-05-01

    We study the depth of decision trees for diagnosis of constant faults in read-once contact networks over finite bases. This includes diagnosis of 0-1 faults, 0 faults and 1 faults. For any finite basis, we prove a linear upper bound on the minimum depth of decision tree for diagnosis of constant faults depending on the number of edges in a contact network over that basis. Also, we obtain asymptotic bounds on the depth of decision trees for diagnosis of each type of constant faults depending on the number of edges in contact networks in the worst case per basis. We study the set of indecomposable contact networks with up to 10 edges and obtain sharp coefficients for the linear upper bound for diagnosis of constant faults in contact networks over bases of these indecomposable contact networks. We use a set of algorithms, including one that we create, to obtain the sharp coefficients.

  20. Structural system reliability calculation using a probabilistic fault tree analysis method

    Science.gov (United States)

    Torng, T. Y.; Wu, Y.-T.; Millwater, H. R.

    1992-01-01

    The development of a new probabilistic fault tree analysis (PFTA) method for calculating structural system reliability is summarized. The proposed PFTA procedure includes: developing a fault tree to represent the complex structural system, constructing an approximation function for each bottom event, determining a dominant sampling sequence for all bottom events, and calculating the system reliability using an adaptive importance sampling method. PFTA is suitable for complicated structural problems that require computer-intensive computer calculations. A computer program has been developed to implement the PFTA.

  1. Fault tree analysis of the manufacturing process of nuclear fuel containers

    International Nuclear Information System (INIS)

    Liao Weixian; Men Dechun; Sui Yuxue

    1998-08-01

    The nuclear fuel container consists of barrel body, bottom, cover, locking ring, rubber seal ring, and so on. It should be kept sealed in transportation and storage, so keeps the fuel contained from leakage. Its manufacturing process includes blanking, forming, seam welding, assembling, derusting and painting. The seam welding and assembling of barrel body and bottom are two key procedures, and the slope grinding, barrel body flaring and deep drawing of the bottom are important procedures. Faults in the manufacturing process of the nuclear fuel containers are investigated in details as for its quality requirements. A fault tree is established with products being unqualified as the top event. Five causes resulting in process faults are classified and analysed, and some measures are suggested for controlling different failures in manufacturing. More research work should be conducted in rules how to set up fault trees for manufacturing process

  2. Fault tree analysis of KNICS RPS software

    International Nuclear Information System (INIS)

    Park, Gee Yong; Kwon, Kee Choon; Koh, Kwang Yong; Jee, Eun Kyoung; Seong, Poong Hyun; Lee, Dae Hyung

    2008-01-01

    This paper describes the application of a software Fault Tree Analysis (FTA) as one of the analysis techniques for a Software Safety Analysis (SSA) at the design phase and its analysis results for the safety-critical software of a digital reactor protection system, which is called the KNICS RPS, being developed in the KNICS (Korea Nuclear Instrumentation and Control Systems) project. The software modules in the design description were represented by Function Blocks (FBs), and the software FTA was performed based on the well-defined fault tree templates for the FBs. The SSA, which is part of the verification and validation (V and V) activities, was activated at each phase of the software lifecycle for the KNICS RPS. At the design phase, the software HAZOP (Hazard and Operability) and the software FTA were employed in the SSA in such a way that the software HAZOP was performed first and then the software FTA was applied. The software FTA was applied to some critical modules selected from the software HAZOP analysis

  3. Application of subset simulation methods to dynamic fault tree analysis

    International Nuclear Information System (INIS)

    Liu Mengyun; Liu Jingquan; She Ding

    2015-01-01

    Although fault tree analysis has been implemented in the nuclear safety field over the past few decades, it was recently criticized for the inability to model the time-dependent behaviors. Several methods are proposed to overcome this disadvantage, and dynamic fault tree (DFT) has become one of the research highlights. By introducing additional dynamic gates, DFT is able to describe the dynamic behaviors like the replacement of spare components or the priority of failure events. Using Monte Carlo simulation (MCS) approach to solve DFT has obtained rising attention, because it can model the authentic behaviors of systems and avoid the limitations in the analytical method. In this paper, it provides an overview and MCS information for DFT analysis, including the sampling of basic events and the propagation rule for logic gates. When calculating rare-event probability, large amount of simulations in standard MCS are required. To improve the weakness, subset simulation (SS) approach is applied. Using the concept of conditional probability and Markov Chain Monte Carlo (MCMC) technique, the SS method is able to accelerate the efficiency of exploring the failure region. Two cases are tested to illustrate the performance of SS approach, and the numerical results suggest that it gives high efficiency when calculating complicated systems with small failure probabilities. (author)

  4. Fault tree analysis of loss of cooling to a HALW storage tank

    International Nuclear Information System (INIS)

    Nomura, Yasushi

    1992-01-01

    Results of a scenario identification, a fault tree construction and an analysis for a loss of cooling accident in a High Activity Liquid Waste (HALW) tank of a typical model of reprocessing facility, is rendered together with considerations of the system reliability improvement by changing the model design. Model plant data, basic failure frequency data and a fault tree analysis named FTL have been introduced from NUKEM GmbH, Germany. They are throughly reviewed and reevaluated at JAERI, and improved to apply to Japanese facilities. A general systematic method for constructing fault trees is used to avoid missing scenarios, thus all of the 10 conceivable accident scenarios for 'HALW storage tank without cooling, HALW boiling' are identified, and a total failure frequency are calculated to be in the 90 % confidence interval of (1.1 ∼ 5.8) x 10 -6 /yr for the German model plant. (author)

  5. Comparison of event tree, fault tree and Markov methods for probabilistic safety assessment and application to accident mitigation

    International Nuclear Information System (INIS)

    James, H.; Harris, M.J.; Hall, S.F.

    1992-01-01

    Probabilistic safety assessment (PSA) is used extensively in the nuclear industry. The main stages of PSA and the traditional event tree method are described. Focussing on hydrogen explosions, an event tree model is compared to a novel Markov model and a fault tree, and unexpected implication for accident mitigation is revealed. (author)

  6. Improving software requirements specification for safety-related systems using the fault tree developed by an object-based method

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1998-01-01

    A modification of the fault tree analysis is presented. The new fault tree integrates structural and behavioral models of a system. Information on the system structure is captured in the name of each gate and basic event of the fault tree. Information on the system behavior is captured in their description. Behavior is expressed using the axiomatic notation based on first order predicate logic. The new fault tree is a useful model for analysis and improvement of software requirements specification. The benefit of such improvements is reduced probability of failures in specification, which in turn results in increased reliability of the software.(author)

  7. SALP-PC, a computer program for fault tree analysis on personal computers

    International Nuclear Information System (INIS)

    Contini, S.; Poucet, A.

    1987-01-01

    The paper presents the main characteristics of the SALP-PC computer code for fault tree analysis. The program has been developed in Fortran 77 on an Olivetti M24 personal computer (IBM compatible) in order to reach a high degree of portability. It is composed of six processors implementing the different phases of the analysis procedure. This particular structure presents some advantages like, for instance, the restart facility and the possibility to develop an event tree analysis code. The set of allowed logical operators, i.e. AND, OR, NOT, K/N, XOR, INH, together with the possibility to define boundary conditions, make the SALP-PC code a powerful tool for risk assessment. (orig.)

  8. San Onofre/Zion auxiliary feedwater system seismic fault tree modeling

    International Nuclear Information System (INIS)

    Najafi, B.; Eide, S.

    1982-02-01

    As part of the study for the seismic evaluation of the San Onofre Unit 1 Auxiliary Feedwater System (AFWS), a fault tree model was developed capable of handling the effect of structural failure of the plant (in the event of an earthquake) on the availability of the AFWS. A compatible fault tree model was developed for the Zion Unit 1 AFWS in order to compare the results of the two systems. It was concluded that if a single failure of the San Onofre Unit 1 AFWS is to be prevented, some weight existing, locally operated locked open manual valves have to be used for isolation of a rupture in specific parts of the AFWS pipings

  9. Fault tree analysis for vital area identification

    International Nuclear Information System (INIS)

    Varnado, G.B.; Ortiz, N.R.

    1978-01-01

    The use of fault tree analysis techniques to systematically identify (1) the sabotage events which can lead to release of significant quantities of radioactive materials, (2) the areas of the nuclear power plant in which the sabotage events can be accomplished, and (3) the areas of the plant which must be protected to assure that release does not occur are discussed

  10. Probabilistic Risk Assessment of Hydraulic Fracturing in Unconventional Reservoirs by Means of Fault Tree Analysis: An Initial Discussion

    Science.gov (United States)

    Rodak, C. M.; McHugh, R.; Wei, X.

    2016-12-01

    The development and combination of horizontal drilling and hydraulic fracturing has unlocked unconventional hydrocarbon reserves around the globe. These advances have triggered a number of concerns regarding aquifer contamination and over-exploitation, leading to scientific studies investigating potential risks posed by directional hydraulic fracturing activities. These studies, balanced with potential economic benefits of energy production, are a crucial source of information for communities considering the development of unconventional reservoirs. However, probabilistic quantification of the overall risk posed by hydraulic fracturing at the system level are rare. Here we present the concept of fault tree analysis to determine the overall probability of groundwater contamination or over-exploitation, broadly referred to as the probability of failure. The potential utility of fault tree analysis for the quantification and communication of risks is approached with a general application. However, the fault tree design is robust and can handle various combinations of regional-specific data pertaining to relevant spatial scales, geological conditions, and industry practices where available. All available data are grouped into quantity and quality-based impacts and sub-divided based on the stage of the hydraulic fracturing process in which the data is relevant as described by the USEPA. Each stage is broken down into the unique basic events required for failure; for example, to quantify the risk of an on-site spill we must consider the likelihood, magnitude, composition, and subsurface transport of the spill. The structure of the fault tree described above can be used to render a highly complex system of variables into a straightforward equation for risk calculation based on Boolean logic. This project shows the utility of fault tree analysis for the visual communication of the potential risks of hydraulic fracturing activities on groundwater resources.

  11. Failure rate modeling using fault tree analysis and Bayesian network: DEMO pulsed operation turbine study case

    International Nuclear Information System (INIS)

    Dongiovanni, Danilo Nicola; Iesmantas, Tomas

    2016-01-01

    Highlights: • RAMI (Reliability, Availability, Maintainability and Inspectability) assessment of secondary heat transfer loop for a DEMO nuclear fusion plant. • Definition of a fault tree for a nuclear steam turbine operated in pulsed mode. • Turbine failure rate models update by mean of a Bayesian network reflecting the fault tree analysis in the considered scenario. • Sensitivity analysis on system availability performance. - Abstract: Availability will play an important role in the Demonstration Power Plant (DEMO) success from an economic and safety perspective. Availability performance is commonly assessed by Reliability Availability Maintainability Inspectability (RAMI) analysis, strongly relying on the accurate definition of system components failure modes (FM) and failure rates (FR). Little component experience is available in fusion application, therefore requiring the adaptation of literature FR to fusion plant operating conditions, which may differ in several aspects. As a possible solution to this problem, a new methodology to extrapolate/estimate components failure rate under different operating conditions is presented. The DEMO Balance of Plant nuclear steam turbine component operated in pulse mode is considered as study case. The methodology moves from the definition of a fault tree taking into account failure modes possibly enhanced by pulsed operation. The fault tree is then translated into a Bayesian network. A statistical model for the turbine system failure rate in terms of subcomponents’ FR is hence obtained, allowing for sensitivity analyses on the structured mixture of literature and unknown FR data for which plausible value intervals are investigated to assess their impact on the whole turbine system FR. Finally, the impact of resulting turbine system FR on plant availability is assessed exploiting a Reliability Block Diagram (RBD) model for a typical secondary cooling system implementing a Rankine cycle. Mean inherent availability

  12. Failure rate modeling using fault tree analysis and Bayesian network: DEMO pulsed operation turbine study case

    Energy Technology Data Exchange (ETDEWEB)

    Dongiovanni, Danilo Nicola, E-mail: danilo.dongiovanni@enea.it [ENEA, Nuclear Fusion and Safety Technologies Department, via Enrico Fermi 45, Frascati 00040 (Italy); Iesmantas, Tomas [LEI, Breslaujos str. 3 Kaunas (Lithuania)

    2016-11-01

    Highlights: • RAMI (Reliability, Availability, Maintainability and Inspectability) assessment of secondary heat transfer loop for a DEMO nuclear fusion plant. • Definition of a fault tree for a nuclear steam turbine operated in pulsed mode. • Turbine failure rate models update by mean of a Bayesian network reflecting the fault tree analysis in the considered scenario. • Sensitivity analysis on system availability performance. - Abstract: Availability will play an important role in the Demonstration Power Plant (DEMO) success from an economic and safety perspective. Availability performance is commonly assessed by Reliability Availability Maintainability Inspectability (RAMI) analysis, strongly relying on the accurate definition of system components failure modes (FM) and failure rates (FR). Little component experience is available in fusion application, therefore requiring the adaptation of literature FR to fusion plant operating conditions, which may differ in several aspects. As a possible solution to this problem, a new methodology to extrapolate/estimate components failure rate under different operating conditions is presented. The DEMO Balance of Plant nuclear steam turbine component operated in pulse mode is considered as study case. The methodology moves from the definition of a fault tree taking into account failure modes possibly enhanced by pulsed operation. The fault tree is then translated into a Bayesian network. A statistical model for the turbine system failure rate in terms of subcomponents’ FR is hence obtained, allowing for sensitivity analyses on the structured mixture of literature and unknown FR data for which plausible value intervals are investigated to assess their impact on the whole turbine system FR. Finally, the impact of resulting turbine system FR on plant availability is assessed exploiting a Reliability Block Diagram (RBD) model for a typical secondary cooling system implementing a Rankine cycle. Mean inherent availability

  13. RAFT: a computer program for fault tree risk calculations

    International Nuclear Information System (INIS)

    Seybold, G.D.

    1977-11-01

    A description and user instructions are presented for RAFT, a FORTRAN computer code for calculation of a risk measure for fault tree cut sets. RAFT calculates release quantities and a risk measure based on the product of probability and release quantity for cut sets of fault trees modeling the accidental release of radioactive material from a nuclear fuel cycle facility. Cut sets and their probabilities are supplied as input to RAFT from an external fault tree analysis code. Using the total inventory available of radioactive material, along with release fractions for each event in a cut set, the release terms are calculated for each cut set. Each release term is multiplied by the cut set probability to yield the cut set risk measure. RAFT orders the dominant cut sets on the risk measure. The total risk measure of processed cut sets and their fractional contributions are supplied as output. Input options are available to eliminate redundant cut sets, apply threshold values on cut set probability and risk, and control the total number of cut sets output. Hash addressing is used to remove redundant cut sets from the analysis. Computer hardware and software restrictions are given along with a sample problem and cross-reference table of the code. Except for the use of file management utilities, RAFT is written exclusively in FORTRAN language and is operational on a Control Data, CYBER 74-18--series computer system. 4 figures

  14. Fault tree construction of hybrid system requirements using qualitative formal method

    International Nuclear Information System (INIS)

    Lee, Jang-Soo; Cha, Sung-Deok

    2005-01-01

    When specifying requirements for software controlling hybrid systems and conducting safety analysis, engineers experience that requirements are often known only in qualitative terms and that existing fault tree analysis techniques provide little guidance on formulating and evaluating potential failure modes. In this paper, we propose Causal Requirements Safety Analysis (CRSA) as a technique to qualitatively evaluate causal relationship between software faults and physical hazards. This technique, extending qualitative formal method process and utilizing information captured in the state trajectory, provides specific guidelines on how to identify failure modes and relationship among them. Using a simplified electrical power system as an example, we describe step-by-step procedures of conducting CRSA. Our experience of applying CRSA to perform fault tree analysis on requirements for the Wolsong nuclear power plant shutdown system indicates that CRSA is an effective technique in assisting safety engineers

  15. Decision tree and PCA-based fault diagnosis of rotating machinery

    Science.gov (United States)

    Sun, Weixiang; Chen, Jin; Li, Jiaqing

    2007-04-01

    After analysing the flaws of conventional fault diagnosis methods, data mining technology is introduced to fault diagnosis field, and a new method based on C4.5 decision tree and principal component analysis (PCA) is proposed. In this method, PCA is used to reduce features after data collection, preprocessing and feature extraction. Then, C4.5 is trained by using the samples to generate a decision tree model with diagnosis knowledge. At last the tree model is used to make diagnosis analysis. To validate the method proposed, six kinds of running states (normal or without any defect, unbalance, rotor radial rub, oil whirl, shaft crack and a simultaneous state of unbalance and radial rub), are simulated on Bently Rotor Kit RK4 to test C4.5 and PCA-based method and back-propagation neural network (BPNN). The result shows that C4.5 and PCA-based diagnosis method has higher accuracy and needs less training time than BPNN.

  16. TH-EF-BRC-03: Fault Tree Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Thomadsen, B. [University of Wisconsin (United States)

    2016-06-15

    This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

  17. TH-EF-BRC-03: Fault Tree Analysis

    International Nuclear Information System (INIS)

    Thomadsen, B.

    2016-01-01

    This Hands-on Workshop will be focused on providing participants with experience with the principal tools of TG 100 and hence start to build both competence and confidence in the use of risk-based quality management techniques. The three principal tools forming the basis of TG 100’s risk analysis: Process mapping, Failure-Modes and Effects Analysis and fault-tree analysis will be introduced with a 5 minute refresher presentation and each presentation will be followed by a 30 minute small group exercise. An exercise on developing QM from the risk analysis follows. During the exercise periods, participants will apply the principles in 2 different clinical scenarios. At the conclusion of each exercise there will be ample time for participants to discuss with each other and the faculty their experience and any challenges encountered. Learning Objectives: To review the principles of Process Mapping, Failure Modes and Effects Analysis and Fault Tree Analysis. To gain familiarity with these three techniques in a small group setting. To share and discuss experiences with the three techniques with faculty and participants. Director, TreatSafely, LLC. Director, Center for the Assessment of Radiological Sciences. Occasional Consultant to the IAEA and Varian.

  18. Fault isolability conditions for linear systems with additive faults

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Stoustrup, Jakob

    2006-01-01

    In this paper, we shall show that an unlimited number of additive single faults can be isolated under mild conditions if a general isolation scheme is applied. Multiple faults are also covered. The approach is algebraic and is based on a set representation of faults, where all faults within a set...

  19. Fault isolatability conditions for linear systems

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Niemann, Henrik

    2006-01-01

    In this paper, we shall show that an unlimited number of additive single faults can be isolated under mild conditions if a general isolation scheme is applied. Multiple faults are also covered. The approach is algebraic and is based on a set representation of faults, where all faults within a set...... the faults have occurred. The last step is a fault isolation (FI) of the faults occurring in a specific fault set, i.e. equivalent with the standard FI step. A simple example demonstrates how to turn the algebraic necessary and sufficient conditions into explicit algorithms for designing filter banks, which...

  20. Diagnosis of Constant Faults in Read-Once Contact Networks over Finite Bases using Decision Trees

    KAUST Repository

    Busbait, Monther I.

    2014-01-01

    We study the depth of decision trees for diagnosis of constant faults in read-once contact networks over finite bases. This includes diagnosis of 0-1 faults, 0 faults and 1 faults. For any finite basis, we prove a linear upper bound on the minimum

  1. Direct evaluation of fault trees using object-oriented programming techniques

    Science.gov (United States)

    Patterson-Hine, F. A.; Koen, B. V.

    1989-01-01

    Object-oriented programming techniques are used in an algorithm for the direct evaluation of fault trees. The algorithm combines a simple bottom-up procedure for trees without repeated events with a top-down recursive procedure for trees with repeated events. The object-oriented approach results in a dynamic modularization of the tree at each step in the reduction process. The algorithm reduces the number of recursive calls required to solve trees with repeated events and calculates intermediate results as well as the solution of the top event. The intermediate results can be reused if part of the tree is modified. An example is presented in which the results of the algorithm implemented with conventional techniques are compared to those of the object-oriented approach.

  2. Application of Fault Tree Analysis for Estimating Temperature Alarm Circuit Reliability

    International Nuclear Information System (INIS)

    El-Shanshoury, A.I.; El-Shanshoury, G.I.

    2011-01-01

    Fault Tree Analysis (FTA) is one of the most widely-used methods in system reliability analysis. It is a graphical technique that provides a systematic description of the combinations of possible occurrences in a system, which can result in an undesirable outcome. The presented paper deals with the application of FTA method in analyzing temperature alarm circuit. The criticality failure of this circuit comes from failing to alarm when temperature exceeds a certain limit. In order for a circuit to be safe, a detailed analysis of the faults causing circuit failure is performed by configuring fault tree diagram (qualitative analysis). Calculations of circuit quantitative reliability parameters such as Failure Rate (FR) and Mean Time between Failures (MTBF) are also done by using Relex 2009 computer program. Benefits of FTA are assessing system reliability or safety during operation, improving understanding of the system, and identifying root causes of equipment failures

  3. A fast BDD algorithm for large coherent fault trees analysis

    International Nuclear Information System (INIS)

    Jung, Woo Sik; Han, Sang Hoon; Ha, Jaejoo

    2004-01-01

    Although a binary decision diagram (BDD) algorithm has been tried to solve large fault trees until quite recently, they are not efficiently solved in a short time since the size of a BDD structure exponentially increases according to the number of variables. Furthermore, the truncation of If-Then-Else (ITE) connectives by the probability or size limit and the subsuming to delete subsets could not be directly applied to the intermediate BDD structure under construction. This is the motivation for this work. This paper presents an efficient BDD algorithm for large coherent systems (coherent BDD algorithm) by which the truncation and subsuming could be performed in the progress of the construction of the BDD structure. A set of new formulae developed in this study for AND or OR operation between two ITE connectives of a coherent system makes it possible to delete subsets and truncate ITE connectives with a probability or size limit in the intermediate BDD structure under construction. By means of the truncation and subsuming in every step of the calculation, large fault trees for coherent systems (coherent fault trees) are efficiently solved in a short time using less memory. Furthermore, the coherent BDD algorithm from the aspect of the size of a BDD structure is much less sensitive to variable ordering than the conventional BDD algorithm

  4. MOCUS, Minimal Cut Sets and Minimal Path Sets from Fault Tree Analysis

    International Nuclear Information System (INIS)

    Fussell, J.B.; Henry, E.B.; Marshall, N.H.

    1976-01-01

    1 - Description of problem or function: From a description of the Boolean failure logic of a system, called a fault tree, and control parameters specifying the minimal cut set length to be obtained MOCUS determines the system failure modes, or minimal cut sets, and the system success modes, or minimal path sets. 2 - Method of solution: MOCUS uses direct resolution of the fault tree into the cut and path sets. The algorithm used starts with the main failure of interest, the top event, and proceeds to basic independent component failures, called primary events, to resolve the fault tree to obtain the minimal sets. A key point of the algorithm is that an and gate alone always increases the number of path sets; an or gate alone always increases the number of cut sets and increases the size of path sets. Other types of logic gates must be described in terms of and and or logic gates. 3 - Restrictions on the complexity of the problem: Output from MOCUS can include minimal cut and path sets for up to 20 gates

  5. Fault Current Characteristics of the DFIG under Asymmetrical Fault Conditions

    Directory of Open Access Journals (Sweden)

    Fan Xiao

    2015-09-01

    Full Text Available During non-severe fault conditions, crowbar protection is not activated and the rotor windings of a doubly-fed induction generator (DFIG are excited by the AC/DC/AC converter. Meanwhile, under asymmetrical fault conditions, the electrical variables oscillate at twice the grid frequency in synchronous dq frame. In the engineering practice, notch filters are usually used to extract the positive and negative sequence components. In these cases, the dynamic response of a rotor-side converter (RSC and the notch filters have a large influence on the fault current characteristics of the DFIG. In this paper, the influence of the notch filters on the proportional integral (PI parameters is discussed and the simplified calculation models of the rotor current are established. Then, the dynamic performance of the stator flux linkage under asymmetrical fault conditions is also analyzed. Based on this, the fault characteristics of the stator current under asymmetrical fault conditions are studied and the corresponding analytical expressions of the stator fault current are obtained. Finally, digital simulation results validate the analytical results. The research results are helpful to meet the requirements of a practical short-circuit calculation and the construction of a relaying protection system for the power grid with penetration of DFIGs.

  6. Recent advancements in fault tree methodology at Karlsruhe

    International Nuclear Information System (INIS)

    Caldarola, L.; Wickenhaeuser, A.

    1977-01-01

    A very fast analytical computer program for fault tree evaluation has already been developed at the German nuclear research center of Karlsruhe. This program can evaluate coherent systems assuming binary component states. Four different classes of components can be handled by the program: (1) unrepairable components, (2) repairable components with revealed faults, (3) repairable components with faults remaining unrevealed until next demand occurs and (4) repairable components with faults which are detected upon inspection. The program can perform also time dependent calculations. In particular the program can analyse systems characterized by two phases, one following the other in time (two time axis). A new computer program is also being developed. This computer program will be capable to analyse noncoherent systems with multistate components. The mathematical theory supporting the new program is described in the paper. In particular the algorithm for the identification of the prime implicants and the theory for the calculation of the occurrence probability and of the first occurrence probability of the TOP event are discussed

  7. Criteria for evaluating protection from single points of failure for partially expanded fault trees

    International Nuclear Information System (INIS)

    Aswani, D.; Badreddine, B.; Malone, M.; Gauthier, G.; Proietty, J.

    2008-01-01

    Fault tree analysis (FTA) is a technique that describes the combinations of events in a system which result in an undesirable outcome. FTA is used as a tool to quantitatively assess a system's probability for an undesirable outcome. Time constraints from concept to production in modern engineering often limit the opportunity for a thorough statistical analysis of a system. Furthermore, when undesirable outcomes are considered such as hazard to human(s), it becomes difficult to identify strict statistical targets for what is acceptable. Consequently, when hazard to human(s) is concerned a common design target is to protect the system from single points of failure (SPOF) which means that no failure mode caused by a single event, concern, or error has a critical consequence on the system. Such a design target is common with 'by-wire' systems. FTA can be used to verify if a system is protected from SPOF. In this paper, sufficient criteria for evaluating protection from SPOF for partially expanded fault trees are proposed along with proof. The proposed criteria consider potential interactions between the lowest drawn events of a partial fault tree expansion which otherwise easily leads to an overly optimistic analysis of protection from SPOF. The analysis is limited to fault trees that are coherent and static

  8. Quantitative security and safety analysis with attack-fault trees

    NARCIS (Netherlands)

    Kumar, Rajesh; Stoelinga, Mariëlle Ida Antoinette

    2017-01-01

    Cyber physical systems, like power plants, medical devices and data centers have to meet high standards, both in terms of safety (i.e. absence of unintentional failures) and security (i.e. no disruptions due to malicious attacks). This paper presents attack fault trees (AFTs), a formalism that

  9. Reliability database development for use with an object-oriented fault tree evaluation program

    Science.gov (United States)

    Heger, A. Sharif; Harringtton, Robert J.; Koen, Billy V.; Patterson-Hine, F. Ann

    1989-01-01

    A description is given of the development of a fault-tree analysis method using object-oriented programming. In addition, the authors discuss the programs that have been developed or are under development to connect a fault-tree analysis routine to a reliability database. To assess the performance of the routines, a relational database simulating one of the nuclear power industry databases has been constructed. For a realistic assessment of the results of this project, the use of one of existing nuclear power reliability databases is planned.

  10. Event and fault tree model for reliability analysis of the greek research reactor

    International Nuclear Information System (INIS)

    Albuquerque, Tob R.; Guimaraes, Antonio C.F.; Moreira, Maria de Lourdes

    2013-01-01

    Fault trees and event trees are widely used in industry to model and to evaluate the reliability of safety systems. Detailed analyzes in nuclear installations require the combination of these two techniques. This work uses the methods of fault tree (FT) and event tree (ET) to perform the Probabilistic Safety Assessment (PSA) in research reactors. The PSA according to IAEA (International Atomic Energy Agency) is divided into Level 1, Level 2 and level 3. At Level 1, conceptually safety systems act to prevent the accident, at Level 2, the accident occurred and seeks to minimize the consequences, known as stage management of the accident, and at Level 3 are determined consequences. This paper focuses on Level 1 studies, and searches through the acquisition of knowledge consolidation of methodologies for future reliability studies. The Greek Research Reactor, GRR - 1, was used as a case example. The LOCA (Loss of Coolant Accident) was chosen as the initiating event and from there were developed the possible accident sequences, using event tree, which could lead damage to the core. Furthermore, for each of the affected systems, the possible accidents sequences were made fault tree and evaluated the probability of each event top of the FT. The studies were conducted using a commercial computational tool SAPHIRE. The results thus obtained, performance or failure to act of the systems analyzed were considered satisfactory. This work is directed to the Greek Research Reactor due to data availability. (author)

  11. Event and fault tree model for reliability analysis of the greek research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Tob R.; Guimaraes, Antonio C.F.; Moreira, Maria de Lourdes, E-mail: atalbuquerque@ien.gov.br, E-mail: btony@ien.gov.br, E-mail: malu@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    Fault trees and event trees are widely used in industry to model and to evaluate the reliability of safety systems. Detailed analyzes in nuclear installations require the combination of these two techniques. This work uses the methods of fault tree (FT) and event tree (ET) to perform the Probabilistic Safety Assessment (PSA) in research reactors. The PSA according to IAEA (International Atomic Energy Agency) is divided into Level 1, Level 2 and level 3. At Level 1, conceptually safety systems act to prevent the accident, at Level 2, the accident occurred and seeks to minimize the consequences, known as stage management of the accident, and at Level 3 are determined consequences. This paper focuses on Level 1 studies, and searches through the acquisition of knowledge consolidation of methodologies for future reliability studies. The Greek Research Reactor, GRR - 1, was used as a case example. The LOCA (Loss of Coolant Accident) was chosen as the initiating event and from there were developed the possible accident sequences, using event tree, which could lead damage to the core. Furthermore, for each of the affected systems, the possible accidents sequences were made fault tree and evaluated the probability of each event top of the FT. The studies were conducted using a commercial computational tool SAPHIRE. The results thus obtained, performance or failure to act of the systems analyzed were considered satisfactory. This work is directed to the Greek Research Reactor due to data availability. (author)

  12. WAMCUT, a computer code for fault tree evaluation. Final report

    International Nuclear Information System (INIS)

    Erdmann, R.C.

    1978-06-01

    WAMCUT is a code in the WAM family which produces the minimum cut sets (MCS) for a given fault tree. The MCS are useful as they provide a qualitative evaluation of a system, as well as providing a means of determining the probability distribution function for the top of the tree. The program is very efficient and will produce all the MCS in a very short computer time span. 22 figures, 4 tables

  13. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) Version 5.0. Fault tree, event tree, and piping ampersand instrumentation diagram (FEP) editors reference manual: Volume 7

    International Nuclear Information System (INIS)

    McKay, M.K.; Skinner, N.L.; Wood, S.T.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System

  14. CAT: a computer code for the automated construction of fault trees

    International Nuclear Information System (INIS)

    Apostolakis, G.E.; Salem, S.L.; Wu, J.S.

    1978-03-01

    A computer code, CAT (Computer Automated Tree, is presented which applies decision table methods to model the behavior of components for systematic construction of fault trees. The decision tables for some commonly encountered mechanical and electrical components are developed; two nuclear subsystems, a Containment Spray Recirculation System and a Consequence Limiting Control System, are analyzed to demonstrate the applications of CAT code

  15. Algorithms and programs for evaluating fault trees with multi-state components

    International Nuclear Information System (INIS)

    Wickenhaeuser, A.

    1989-07-01

    Part 1 and 2 of the report contain a summary overview of methods and algorithms for the solution of fault tree analysis problems. The following points are treated in detail: Treatment of fault tree components with more than two states. Acceleration of the solution algorithms. Decomposition and modularization of extensive systems. Calculation of the structural function and the exact occurrence probability. Treatment of statistical dependencies. A flexible tool to be employed in solving these problems is the method of forming Boolean variables with restrictions. In this way, components with more than two states can be treated, the possibilities of forming modules expanded, and statistical dependencies treated. Part 3 contains descriptions of the MUSTAFA, MUSTAMO, PASPI, and SIMUST computer programs based on these methods. (orig./HP) [de

  16. Fuzzy set theoretic approach to fault tree analysis | Tyagi ...

    African Journals Online (AJOL)

    This approach can be widely used to improve the reliability and to reduce the operating cost of a system. The proposed techniques are discussed and illustrated by taking an example of a nuclear power plant. Keywords: Fault tree, Triangular and Trapezoidal fuzzy number, Fuzzy importance, Ranking of fuzzy numbers ...

  17. Users' manual for fault tree analysis code: CUT-TD

    International Nuclear Information System (INIS)

    Watanabe, Norio; Kiyota, Mikio.

    1992-06-01

    The CUT-TD code has been developed to find minimal cut sets for a given fault tree and to calculate the occurrence probability of its top event. This code uses an improved top-down algorithm which can enhance the efficiency in deriving minimal cut sets. The features in processing techniques incorporated into CUT-TD are as follows: (1) Consecutive OR gates or consecutive AND gates can be coalesced into a single gate. As a result, this processing directly produces cut sets for the redefined single gate with each gate not being developed. (2) The independent subtrees are automatically identified and their respective cut sets are separately found to enhance the efficiency in processing. (3) The minimal cut sets can be obtained for the top event of a fault tree by combining their respective minimal cut sets for several gates of the fault tree. (4) The user can reduce the computing time for finding minimal cut sets and control the size and significance of cut sets by inputting a minimum probability cut off and/or a maximum order cut off. (5) The user can select events that need not to be further developed in the process of obtaining minimal cut sets. This option can reduce the number of minimal cut sets, save the computing time and assists the user in reviewing the result. (6) Computing time is monitored by the CUT-TD code so that it can prevent the running job from abnormally ending due to excessive CPU time and produce an intermediate result. The CUT-TD code has the ability to restart the calculation with use of the intermediate result. This report provides a users' manual for the CUT-TD code. (author)

  18. An Integrated Approach of Model checking and Temporal Fault Tree for System Safety Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Yong; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2009-10-15

    Digitalization of instruments and control systems in nuclear power plants offers the potential to improve plant safety and reliability through features such as increased hardware reliability and stability, and improved failure detection capability. It however makes the systems and their safety analysis more complex. Originally, safety analysis was applied to hardware system components and formal methods mainly to software. For software-controlled or digitalized systems, it is necessary to integrate both. Fault tree analysis (FTA) which has been one of the most widely used safety analysis technique in nuclear industry suffers from several drawbacks as described in. In this work, to resolve the problems, FTA and model checking are integrated to provide formal, automated and qualitative assistance to informal and/or quantitative safety analysis. Our approach proposes to build a formal model of the system together with fault trees. We introduce several temporal gates based on timed computational tree logic (TCTL) to capture absolute time behaviors of the system and to give concrete semantics to fault tree gates to reduce errors during the analysis, and use model checking technique to automate the reasoning process of FTA.

  19. Reliability Analysis of Core Protection Calculator System by Combining Petri Net and Fault Tree

    International Nuclear Information System (INIS)

    Kim, Hyejin; Kim, Jonghyun

    2013-01-01

    This paper proposes an approach to analyzing the reliability of digital systems by combining Petri net (PN) and Fault tree. The Petri net allows modeling event dependencies and interaction, to represent the time sequence, and to model assumptions for dynamic events. The Petri net model can be straightforwardly transformed to fault tree using the gate. Then, the FT can be integrated into the existing PSA. This paper applies the approach to the reliability analysis of Core Protection Calculator System (CPCS). Digital technology is replacing the analog instrumentation and control (I and C) systems in both new and upgraded nuclear power plants. As digital systems are introduced to nuclear power plants, issues related with reliability analyses of these digital systems are being raised. One of these issues is that static fault tree (FT) and event tree (ET) approach cannot properly account for dynamic interactions in the digital systems, such as multiple top events, logic loops and time delay. Many methods have been proposed to solve the problems, but there is no single method that is universally accepted for the application to the current generation probabilistic safety analysis (PSA)

  20. Reliability Analysis of Core Protection Calculator System by Combining Petri Net and Fault Tree

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyejin; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-10-15

    This paper proposes an approach to analyzing the reliability of digital systems by combining Petri net (PN) and Fault tree. The Petri net allows modeling event dependencies and interaction, to represent the time sequence, and to model assumptions for dynamic events. The Petri net model can be straightforwardly transformed to fault tree using the gate. Then, the FT can be integrated into the existing PSA. This paper applies the approach to the reliability analysis of Core Protection Calculator System (CPCS). Digital technology is replacing the analog instrumentation and control (I and C) systems in both new and upgraded nuclear power plants. As digital systems are introduced to nuclear power plants, issues related with reliability analyses of these digital systems are being raised. One of these issues is that static fault tree (FT) and event tree (ET) approach cannot properly account for dynamic interactions in the digital systems, such as multiple top events, logic loops and time delay. Many methods have been proposed to solve the problems, but there is no single method that is universally accepted for the application to the current generation probabilistic safety analysis (PSA)

  1. Quantile arithmetic methodology for uncertainty propagation in fault trees

    International Nuclear Information System (INIS)

    Abdelhai, M.; Ragheb, M.

    1986-01-01

    A methodology based on quantile arithmetic, the probabilistic analog to interval analysis, is proposed for the computation of uncertainties propagation in fault tree analysis. The basic events' continuous probability density functions (pdf's) are represented by equivalent discrete distributions by dividing them into a number of quantiles N. Quantile arithmetic is then used to performthe binary arithmetical operations corresponding to the logical gates in the Boolean expression of the top event expression of a given fault tree. The computational advantage of the present methodology as compared with the widely used Monte Carlo method was demonstrated for the cases of summation of M normal variables through the efficiency ratio defined as the product of the labor and error ratios. The efficiency ratio values obtained by the suggested methodology for M = 2 were 2279 for N = 5, 445 for N = 25, and 66 for N = 45 when compared with the results for 19,200 Monte Carlo samples at the 40th percentile point. Another advantage of the approach is that the exact analytical value of the median is always obtained for the top event

  2. Methodology for reliability allocation based on fault tree analysis and dualistic contrast

    Institute of Scientific and Technical Information of China (English)

    TONG Lili; CAO Xuewu

    2008-01-01

    Reliability allocation is a difficult multi-objective optimization problem.This paper presents a methodology for reliability allocation that can be applied to determine the reliability characteristics of reactor systems or subsystems.The dualistic contrast,known as one of the most powerful tools for optimization problems,is applied to the reliability allocation model of a typical system in this article.And the fault tree analysis,deemed to be one of the effective methods of reliability analysis,is also adopted.Thus a failure rate allocation model based on the fault tree analysis and dualistic contrast is achieved.An application on the emergency diesel generator in the nuclear power plant is given to illustrate the proposed method.

  3. Uncertainties related to the fault tree reliability data

    International Nuclear Information System (INIS)

    Apostol, Minodora; Nitoi, Mirela; Farcasiu, M.

    2003-01-01

    Uncertainty analyses related to the fault trees evaluate the system variability which appears from the uncertainties of the basic events probabilities. Having a logical model which describes a system, to obtain outcomes means to evaluate it, using estimations for each basic event of the model. If the model has basic events that incorporate uncertainties, then the results of the model should incorporate the uncertainties of the events. Uncertainties estimation in the final result of the fault tree means first the uncertainties evaluation for the basic event probabilities and then combination of these uncertainties, to calculate the top event uncertainty. To calculate the propagating uncertainty, a knowledge of the probability density function as well as the range of possible values of the basic event probabilities is required. The following data are defined, using suitable probability density function: the components failure rates; the human error probabilities; the initiating event frequencies. It was supposed that the possible value distribution of the basic event probabilities is given by the lognormal probability density function. To know the range of possible value of the basic event probabilities, the error factor or the uncertainty factor is required. The aim of this paper is to estimate the error factor for the failure rates and for the human errors probabilities from the reliability data base used in Cernavoda Probabilistic Safety Evaluation. The top event chosen as an example is FEED3, from the Pressure and Inventory Control System. The quantitative evaluation of this top event was made by using EDFT code, developed in Institute for Nuclear Research Pitesti (INR). It was supposed that the error factors for the component failures are the same as for the failure rates. Uncertainty analysis was made with INCERT application, which uses the moment method and Monte Carlo method. The reliability data base used at INR Pitesti does not contain the error factors (ef

  4. Analytical propagation of uncertainties through fault trees

    International Nuclear Information System (INIS)

    Hauptmanns, Ulrich

    2002-01-01

    A method is presented which enables one to propagate uncertainties described by uniform probability density functions through fault trees. The approach is analytical. It is based on calculating the expected value and the variance of the top event probability. These two parameters are then equated with the corresponding ones of a beta-distribution. An example calculation comparing the analytically calculated beta-pdf (probability density function) with the top event pdf obtained using the Monte-Carlo method shows excellent agreement at a much lower expense of computing time

  5. Fault trees based on past accidents. Factorial analysis of events

    International Nuclear Information System (INIS)

    Vaillant, M.

    1977-01-01

    The method of the fault tree is already useful in the qualitative step before any reliability calculation. The construction of the tree becomes even simpler when we just want to describe how the events happened. Differently from screenplays that introduce several possibilities by means of the conjunction OR, you only have here the conjunction AND, which will not be written at all. This method is presented by INRS (1) for the study of industrial injuries; it may also be applied to material damages. (orig.) [de

  6. Comparing Two Different Approaches to the Modeling of the Common Cause Failures in Fault Trees

    International Nuclear Information System (INIS)

    Vukovic, I.; Mikulicic, V.; Vrbanic, I.

    2002-01-01

    The potential for common cause failures in systems that perform critical functions has been recognized as very important contributor to risk associated with operation of nuclear power plants. Consequentially, modeling of common cause failures (CCF) in fault trees has become one among the essential elements in any probabilistic safety assessment (PSA). Detailed and realistic representation of CCF potential in fault tree structure is sometimes very challenging task. This is especially so in the cases where a common cause group involves more than two components. During the last ten years the difficulties associated with this kind of modeling have been overcome to some degree by development of integral PSA tools with high capabilities. Some of them allow for the definition of CCF groups and their automated expanding in the process of Boolean resolution and generation of minimal cutsets. On the other hand, in PSA models developed and run by more traditional tools, CCF-potential had to be modeled in the fault trees explicitly. With explicit CCF modeling, fault trees can grow very large, especially in the cases when they involve CCF groups with 3 or more members, which can become an issue for the management of fault trees and basic events with traditional non-integral PSA models. For these reasons various simplifications had to be made. Speaking in terms of an overall PSA model, there are also some other issues that need to be considered, such as maintainability and accessibility of the model. In this paper a comparison is made between the two approaches to CCF modeling. Analysis is based on a full-scope Level 1 PSA model for internal initiating events that had originally been developed by a traditional PSA tool and later transferred to a new-generation PSA tool with automated CCF modeling capabilities. Related aspects and issues mentioned above are discussed in the paper. (author)

  7. The constant failure rate model for fault tree evaluation as a tool for unit protection reliability assessment

    International Nuclear Information System (INIS)

    Vichev, S.; Bogdanov, D.

    2000-01-01

    The purpose of this paper is to introduce the fault tree analysis method as a tool for unit protection reliability estimation. The constant failure rate model applies for making reliability assessment, and especially availability assessment. For that purpose an example for unit primary equipment structure and fault tree example for simplified unit protection system is presented (author)

  8. Improving reliability of state estimation programming and computing suite based on analyzing a fault tree

    Directory of Open Access Journals (Sweden)

    Kolosok Irina

    2017-01-01

    Full Text Available Reliable information on the current state parameters obtained as a result of processing the measurements from systems of the SCADA and WAMS data acquisition and processing through methods of state estimation (SE is a condition that enables to successfully manage an energy power system (EPS. SCADA and WAMS systems themselves, as any technical systems, are subject to failures and faults that lead to distortion and loss of information. The SE procedure enables to find erroneous measurements, therefore, it is a barrier for the distorted information to penetrate into control problems. At the same time, the programming and computing suite (PCS implementing the SE functions may itself provide a wrong decision due to imperfection of the software algorithms and errors. In this study, we propose to use a fault tree to analyze consequences of failures and faults in SCADA and WAMS and in the very SE procedure. Based on the analysis of the obtained measurement information and on the SE results, we determine the state estimation PCS fault tolerance level featuring its reliability.

  9. TU-AB-BRD-03: Fault Tree Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dunscombe, P. [University of Calgary (Canada)

    2015-06-15

    Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to

  10. TU-AB-BRD-03: Fault Tree Analysis

    International Nuclear Information System (INIS)

    Dunscombe, P.

    2015-01-01

    Current quality assurance and quality management guidelines provided by various professional organizations are prescriptive in nature, focusing principally on performance characteristics of planning and delivery devices. However, published analyses of events in radiation therapy show that most events are often caused by flaws in clinical processes rather than by device failures. This suggests the need for the development of a quality management program that is based on integrated approaches to process and equipment quality assurance. Industrial engineers have developed various risk assessment tools that are used to identify and eliminate potential failures from a system or a process before a failure impacts a customer. These tools include, but are not limited to, process mapping, failure modes and effects analysis, fault tree analysis. Task Group 100 of the American Association of Physicists in Medicine has developed these tools and used them to formulate an example risk-based quality management program for intensity-modulated radiotherapy. This is a prospective risk assessment approach that analyzes potential error pathways inherent in a clinical process and then ranks them according to relative risk, typically before implementation, followed by the design of a new process or modification of the existing process. Appropriate controls are then put in place to ensure that failures are less likely to occur and, if they do, they will more likely be detected before they propagate through the process, compromising treatment outcome and causing harm to the patient. Such a prospective approach forms the basis of the work of Task Group 100 that has recently been approved by the AAPM. This session will be devoted to a discussion of these tools and practical examples of how these tools can be used in a given radiotherapy clinic to develop a risk based quality management program. Learning Objectives: Learn how to design a process map for a radiotherapy process Learn how to

  11. The use of fault tree analysis to minimize research reactor downtime

    International Nuclear Information System (INIS)

    Dodd, B.; Wang, C.H.; Anderson, T.V.

    1984-01-01

    For many reasons it is often highly desirable to maintain a research reactor in a continuously operable state and in the event of any failures to minimize the length of the reactor downtime. In order to keep the length of future downtimes to less than ten days for the sixteen year old OSU TRIGA reactor, a fault tree analysis was performed for all of the systems required to maintain the reactor operational. As a result of this analysis, it was possible to determine the critical parts and key components. By examining the availability and delivery times for each of these items, it was then possible to make reasoned decisions relating to the advance purchase of spare parts. This paper outlines the above process, along with examples of fault trees developed, and a recent history of the efficacy of this technique. (author)

  12. Using SETS to find minimal cut sets in large fault trees

    International Nuclear Information System (INIS)

    Worrell, R.B.; Stack, D.W.

    1978-01-01

    An efficient algebraic algorithm for finding the minimal cut sets for a large fault tree was defined and a new procedure which implements the algorithm was added to the Set Equation Transformation System (SETS). The algorithm includes the identification and separate processing of independent subtrees, the coalescing of consecutive gates of the same kind, the creation of additional independent subtrees, and the derivation of the fault tree stem equation in stages. The computer time required to determine the minimal cut sets using these techniques is shown to be substantially less than the computer time required to determine the minimal cut sets when these techniques are not employed. It is shown for a given example that the execution time required to determine the minimal cut sets can be reduced from 7,686 seconds to 7 seconds when all of these techniques are employed

  13. On the numerical solution of fault trees

    International Nuclear Information System (INIS)

    Demichela, M.; Piccinini, N.; Ciarambino, I.; Contini, S.

    2003-01-01

    In this paper an account will be given of the numerical solution of the logic trees directly extracted from the Recursive Operability Analysis. Particular attention will be devoted to the use of the NOT and INH logic gates for correct logical representation of Fault Trees prior to their quantitative resolution. The NOT gate is needed for correct logical representation of events when both non-intervention and correct intervention of a protective system may lead to a Top Event. The INH gate must be used to correctly represent the time link between two events that are both necessary, but must occur in sequence. Some numerical examples will be employed to show both the correct identification of the events entering the INH gates and how use of the AND gate instead of the INH gate leads to overestimation of the probability of occurrence of a Top Event

  14. The integration of expert-defined importance factors to enrich Bayesian Fault Tree Analysis

    International Nuclear Information System (INIS)

    Darwish, Molham; Almouahed, Shaban; Lamotte, Florent de

    2017-01-01

    This paper proposes an analysis of a hybrid Bayesian-Importance model for system designers to improve the quality of services related to Active Assisted Living Systems. The proposed model is based on two factors: failure probability measure of different service components and, an expert defined degree of importance that each component holds for the success of the corresponding service. The proposed approach advocates the integration of expert-defined importance factors to enrich the Bayesian Fault Tree Analysis (FTA) approach. The evaluation of the proposed approach is conducted using the Fault Tree Analysis formalism where the undesired state of a system is analyzed using Boolean logic mechanisms to combine a series of lower-level events.

  15. Decision-table development for use with the CAT code for the automated fault-tree construction

    International Nuclear Information System (INIS)

    Wu, J.S.; Salem, S.L.; Apostolakis, G.E.

    1977-01-01

    A library of decision tables to be used in connection with the CAT computer code for the automated construction of fault trees is presented. A decision table is constructed for each component type describing the output of the component in terms of its inputs and its internal states. In addition, a modification of the CAT code that couples it with a fault tree analysis code is presented. This report represents one aspect of a study entitled, 'A General Evaluation Approach to Risk-Benefit for Large Technological Systems, and Its Application to Nuclear Power.'

  16. Automatic fault tree construction with RIKKE - a compendium of examples. Vol. 2

    International Nuclear Information System (INIS)

    Taylor, J.R.

    1982-02-01

    This second volume describes the construction of fault trees for systems with loops, including control and safety loops. It also gives a short summary of the event coding scheme used in the FTLIB component model library. (author)

  17. A Rigorous, Compositional, and Extensible Framework for Dynamic Fault Tree Analysis

    NARCIS (Netherlands)

    Boudali, H.; Sandhu, R.; Crouzen, Pepijn; Stoelinga, Mariëlle Ida Antoinette

    Fault trees (FT) are among the most prominent formalisms for reliability analysis of technical systems. Dynamic FTs extend FTs with support for expressing dynamic dependencies among components. The standard analysis vehicle for DFTs is state-based, and treats the model as a CTMC, a continuous-time

  18. GOTRES: an expert system for fault detection and analysis

    International Nuclear Information System (INIS)

    Chung, D.T.; Modarres, M.

    1989-01-01

    This paper describes a deep-knowledge expert system shell for diagnosing faults in process operations. The expert program shell is called GOTRES (GOal TRee Expert System) and uses a goal tree-success tree deep-knowledge structure to model its knowledge-base. To demonstrate GOTRES, we have built an on-line fault diagnosis expert system for an experimental nuclear reactor facility using this shell. The expert system is capable of diagnosing fault conditions using system goal tree as well as utilizing accumulated operating knowledge to predict plant causal and temporal behaviours. The GOTRES shell has also been used for root-cause detection and analysis in a nuclear plant. (author)

  19. A Study on Landslide Risk Management by Applying Fault Tree Logics

    Directory of Open Access Journals (Sweden)

    Kazmi Danish

    2017-01-01

    Full Text Available Slope stability is one of the focal areas of curiosity to geotechnical designers and also appears logical for the application of probabilistic approaches since the analysis lead to a “probability of failure”. Assessment of the existing slopes in relation with risks seems to be more meaningful when concerning with landslides. Probabilistic slope stability analysis (PSSA is the best option in covering the landslides events. The intent here is to bid a probabilistic framework for quantified risk analysis with human uncertainties. In this regard, Fault Tree Analysis is utilized and for prediction of risk levels, consequences of the failures of the reference landslides have been taken. It is concluded that logics of fault trees is best fit, to clinch additional categories of uncertainty; like human, organizational, and knowledge related. In actual, the approach has been used in bringing together engineering and management performances and personnel, to produce reliability in slope engineering practices.

  20. Post Fire Safe Shutdown Analysis Using a Fault Tree Logic Model

    International Nuclear Information System (INIS)

    Yim, Hyun Tae; Park, Jun Hyun

    2005-01-01

    Every nuclear power plant should have its own fire hazard analysis including the fire safe shutdown analysis. A safe shutdown (SSD) analysis is performed to demonstrate the capability of the plant to safely shut down for a fire in any given area. The basic assumption is that there will be fire damage to all cables and equipment located within a common fire area. When evaluating the SSD capabilities of the plant, based on a review of the systems, equipment and cables within each fire area, it should be determined which shutdown paths are either unaffected or least impacted by a postulated fire within the fire area. Instead of seeking a success path for safe shutdown given all cables and equipment damaged by a fire, there can be an alternative approach to determine the SSD capability: fault tree analysis. This paper introduces the methodology for fire SSD analysis using a fault tree logic model

  1. Fault Tree Analysis with Temporal Gates and Model Checking Technique for Qualitative System Safety Analysis

    International Nuclear Information System (INIS)

    Koh, Kwang Yong; Seong, Poong Hyun

    2010-01-01

    Fault tree analysis (FTA) has suffered from several drawbacks such that it uses only static gates and hence can not capture dynamic behaviors of the complex system precisely, and it is in lack of rigorous semantics, and reasoning process which is to check whether basic events really cause top events is done manually and hence very labor-intensive and time-consuming for the complex systems while it has been one of the most widely used safety analysis technique in nuclear industry. Although several attempts have been made to overcome this problem, they can not still do absolute or actual time modeling because they adapt relative time concept and can capture only sequential behaviors of the system. In this work, to resolve the problems, FTA and model checking are integrated to provide formal, automated and qualitative assistance to informal and/or quantitative safety analysis. Our approach proposes to build a formal model of the system together with fault trees. We introduce several temporal gates based on timed computational tree logic (TCTL) to capture absolute time behaviors of the system and to give concrete semantics to fault tree gates to reduce errors during the analysis, and use model checking technique to automate the reasoning process of FTA

  2. SAFTAC, Monte-Carlo Fault Tree Simulation for System Design Performance and Optimization

    International Nuclear Information System (INIS)

    Crosetti, P.A.; Garcia de Viedma, L.

    1976-01-01

    1 - Description of problem or function: SAFTAC is a Monte Carlo fault tree simulation program that provides a systematic approach for analyzing system design, performing trade-off studies, and optimizing system changes or additions. 2 - Method of solution: SAFTAC assumes an exponential failure distribution for basic input events and a choice of either Gaussian distributed or constant repair times. The program views the system represented by the fault tree as a statistical assembly of independent basic input events, each characterized by an exponential failure distribution and, if used, a constant or normal repair distribution. 3 - Restrictions on the complexity of the problem: The program is dimensioned to handle 1100 basic input events and 1100 logical gates. It can be re-dimensioned to handle up to 2000 basic input events and 2000 logical gates within the existing core memory

  3. Application of fault tree methodology to modeling of the AP1000 plant digital reactor protection system

    International Nuclear Information System (INIS)

    Teolis, D.S.; Zarewczynski, S.A.; Detar, H.L.

    2012-01-01

    The reactor trip system (RTS) and engineered safety features actuation system (ESFAS) in nuclear power plants utilizes instrumentation and control (IC) to provide automatic protection against unsafe and improper reactor operation during steady-state and transient power operations. During normal operating conditions, various plant parameters are continuously monitored to assure that the plant is operating in a safe state. In response to deviations of these parameters from pre-determined set points, the protection system will initiate actions required to maintain the reactor in a safe state. These actions may include shutting down the reactor by opening the reactor trip breakers and actuation of safety equipment based on the situation. The RTS and ESFAS are represented in probabilistic risk assessments (PRAs) to reflect the impact of their contribution to core damage frequency (CDF). The reactor protection systems (RPS) in existing nuclear power plants are generally analog based and there is general consensus within the PRA community on fault tree modeling of these systems. In new plants, such as AP1000 plant, the RPS is based on digital technology. Digital systems are more complex combinations of hardware components and software. This combination of complex hardware and software can result in the presence of faults and failure modes unique to a digital RPS. The United States Nuclear Regulatory Commission (NRC) is currently performing research on the development of probabilistic models for digital systems for inclusion in PRAs; however, no consensus methodology exists at this time. Westinghouse is currently updating the AP1000 plant PRA to support initial operation of plants currently under construction in the United States. The digital RPS is modeled using fault tree methodology similar to that used for analog based systems. This paper presents high level descriptions of a typical analog based RPS and of the AP1000 plant digital RPS. Application of current fault

  4. The Combined Application of Fault Trees and Turbine Cycle Simulation in Generation Risk Assessment

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Park, Jin Kyun

    2009-01-01

    The paper describes a few ideas developed for the framework to quantify human errors taking place during the test and maintenance (T and M) in a secondary system of nuclear power plants, which was presented in the previous meeting. GRA-HRE (Generation Risk Assessment for Human Related Events) is composed of four essential components, the human error interpreter, the frequency estimator, the risk estimator, and the derate estimator. The proposed GRA gave emphasis on explicitly considering human errors, performing fault tree analysis including the entire balance-of-plant side, and quantifying electric loss under abnormal plant configurations. In terms of the consideration of human errors, it was hard to distinguish the effects of human errors from other failure modes in the conventional GRA because the human errors were implicitly involved in mechanical failure mode. Since the risk estimator in GRA-HRE separately deals with the basic events representing human error modes such as control failure, wrong object, omission, wrong action, etc., we can recognize their relative importance comparing with other types of mechanical failures. Other specialties in GRA-HRE came from the combined application of fault tree analysis and turbine cycle simulation. The previous study suggested that we would use the fault tree analysis with the top events designated by system's malfunction such as 'feedwater system failure' to develop the risk estimator. However, this approach could not clearly provide the path of propagation of human errors, and it was difficult to present the failure logics in some cases. In order to overcome these bottlenecks, the paper is going to propose the modified idea to setup top events and to explain how to make use of turbine cycle simulation to complete the fault trees in a cooperative manner

  5. Human Factors Reliability Analysis for Assuring Nuclear Safety Using Fuzzy Fault Tree

    International Nuclear Information System (INIS)

    Eisawy, E.A.-F. I.; Sallam, H.

    2016-01-01

    In order to ensure effective prevention of harmful events, the risk assessment process cannot ignore the role of humans in the dynamics of accidental events and thus the seriousness of the consequences that may derive from them. Human reliability analysis (HRA) involves the use of qualitative and quantitative methods to assess the human contribution to risk. HRA techniques have been developed in order to provide human error probability values associated with operators’ tasks to be included within the broader context of system risk assessment, and are aimed at reducing the probability of accidental events. Fault tree analysis (FTA) is a graphical model that displays the various combinations of equipment failures and human errors that can result in the main system failure of interest. FTA is a risk analysis technique to assess likelihood (in a probabilistic context) of an event. The objective data available to estimate the likelihood is often missing, and even if available, is subject to incompleteness and imprecision or vagueness. Without addressing incompleteness and imprecision in the available data, FTA and subsequent risk analysis give a false impression of precision and correctness that undermines the overall credibility of the process. To solve this problem, qualitative justification in the context of failure possibilities can be used as alternative for quantitative justification. In this paper, we introduce the approach of fuzzy reliability as solution for fault tree analysis drawbacks. A new fuzzy fault tree method is proposed for the analysis of human reliability based on fuzzy sets and fuzzy operations t-norms, co-norms, defuzzification, and fuzzy failure probability. (author)

  6. Irregular recurrence of large earthquakes along the san andreas fault: evidence from trees.

    Science.gov (United States)

    Jacoby, G C; Sheppard, P R; Sieh, K E

    1988-07-08

    Old trees growing along the San Andreas fault near Wrightwood, California, record in their annual ring-width patterns the effects of a major earthquake in the fall or winter of 1812 to 1813. Paleoseismic data and historical information indicate that this event was the "San Juan Capistrano" earthquake of 8 December 1812, with a magnitude of 7.5. The discovery that at least 12 kilometers of the Mojave segment of the San Andreas fault ruptured in 1812, only 44 years before the great January 1857 rupture, demonstrates that intervals between large earthquakes on this part of the fault are highly variable. This variability increases the uncertainty of forecasting destructive earthquakes on the basis of past behavior and accentuates the need for a more fundamental knowledge of San Andreas fault dynamics.

  7. Fault condition stress analysis of NET 16 TF coil model

    International Nuclear Information System (INIS)

    Jong, C.T.J.

    1992-04-01

    As part of the design process of the NET/ITER toroidal field coils (TFCs), the mechanical behaviour of the magnetic system under fault conditions has to be analysed in some detail. Under fault conditions, either electrical or mechanical, the magnetic loading of the coils becomes extreme and further mechanical failure of parts of the overall structure might occur (e.g. failure of the coil, gravitational support, intercoil structure). The mechanical behaviour of the magnetic system under fault conditions has been analysed with a finite element model of the complete TFC system. The analysed fault conditions consist of: a thermal fault, electrical faults and mechanical faults. The mechanical faults have been applied simultaneously with an electrical fault. This report described the work carried out to create the finite element model of 16 TFCs and contains an extensive presentation of the results, obtained with this model, of a normal operating condition analysis and 9 fault condition analyses. Chapter 2-5 contains a detailed description of the finite element model, boundary conditions and loading conditions of the analyses made. Chapters 2-4 can be skipped if the reader is only interested in results. To understand the results presented chapter 6 is recommended, which contains a detailed description of all analysed fault conditions. The dimensions and geometry of the model correspond to the status of the NET/ITER TFC design of May 1990. Compared with previous models of the complete magnetic system, the finite element model of 16 TFCs is 'detailed', and can be used for linear elastic analysis with faulted loads. (author). 8 refs.; 204 figs.; 134 tabs

  8. Reliability analysis of the solar array based on Fault Tree Analysis

    International Nuclear Information System (INIS)

    Wu Jianing; Yan Shaoze

    2011-01-01

    The solar array is an important device used in the spacecraft, which influences the quality of in-orbit operation of the spacecraft and even the launches. This paper analyzes the reliability of the mechanical system and certifies the most vital subsystem of the solar array. The fault tree analysis (FTA) model is established according to the operating process of the mechanical system based on DFH-3 satellite; the logical expression of the top event is obtained by Boolean algebra and the reliability of the solar array is calculated. The conclusion shows that the hinges are the most vital links between the solar arrays. By analyzing the structure importance(SI) of the hinge's FTA model, some fatal causes, including faults of the seal, insufficient torque of the locking spring, temperature in space, and friction force, can be identified. Damage is the initial stage of the fault, so limiting damage is significant to prevent faults. Furthermore, recommendations for improving reliability associated with damage limitation are discussed, which can be used for the redesigning of the solar array and the reliability growth planning.

  9. Reliability analysis of the solar array based on Fault Tree Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wu Jianing; Yan Shaoze, E-mail: yansz@mail.tsinghua.edu.cn [State Key Laboratory of Tribology, Department of Precision Instruments and Mechanology, Tsinghua University,Beijing 100084 (China)

    2011-07-19

    The solar array is an important device used in the spacecraft, which influences the quality of in-orbit operation of the spacecraft and even the launches. This paper analyzes the reliability of the mechanical system and certifies the most vital subsystem of the solar array. The fault tree analysis (FTA) model is established according to the operating process of the mechanical system based on DFH-3 satellite; the logical expression of the top event is obtained by Boolean algebra and the reliability of the solar array is calculated. The conclusion shows that the hinges are the most vital links between the solar arrays. By analyzing the structure importance(SI) of the hinge's FTA model, some fatal causes, including faults of the seal, insufficient torque of the locking spring, temperature in space, and friction force, can be identified. Damage is the initial stage of the fault, so limiting damage is significant to prevent faults. Furthermore, recommendations for improving reliability associated with damage limitation are discussed, which can be used for the redesigning of the solar array and the reliability growth planning.

  10. Rolling bearing fault diagnosis using adaptive deep belief network with dual-tree complex wavelet packet.

    Science.gov (United States)

    Shao, Haidong; Jiang, Hongkai; Wang, Fuan; Wang, Yanan

    2017-07-01

    Automatic and accurate identification of rolling bearing fault categories, especially for the fault severities and compound faults, is a challenge in rotating machinery fault diagnosis. For this purpose, a novel method called adaptive deep belief network (DBN) with dual-tree complex wavelet packet (DTCWPT) is developed in this paper. DTCWPT is used to preprocess the vibration signals to refine the fault characteristics information, and an original feature set is designed from each frequency-band signal of DTCWPT. An adaptive DBN is constructed to improve the convergence rate and identification accuracy with multiple stacked adaptive restricted Boltzmann machines (RBMs). The proposed method is applied to the fault diagnosis of rolling bearings. The results confirm that the proposed method is more effective than the existing methods. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Approximate estimation of system reliability via fault trees

    International Nuclear Information System (INIS)

    Dutuit, Y.; Rauzy, A.

    2005-01-01

    In this article, we show how fault tree analysis, carried out by means of binary decision diagrams (BDD), is able to approximate reliability of systems made of independent repairable components with a good accuracy and a good efficiency. We consider four algorithms: the Murchland lower bound, the Barlow-Proschan lower bound, the Vesely full approximation and the Vesely asymptotic approximation. For each of these algorithms, we consider an implementation based on the classical minimal cut sets/rare events approach and another one relying on the BDD technology. We present numerical results obtained with both approaches on various examples

  12. α-Cut method based importance measure for criticality analysis in fuzzy probability – Based fault tree analysis

    International Nuclear Information System (INIS)

    Purba, Julwan Hendry; Sony Tjahyani, D.T.; Widodo, Surip; Tjahjono, Hendro

    2017-01-01

    Highlights: •FPFTA deals with epistemic uncertainty using fuzzy probability. •Criticality analysis is important for reliability improvement. •An α-cut method based importance measure is proposed for criticality analysis in FPFTA. •The α-cut method based importance measure utilises α-cut multiplication, α-cut subtraction, and area defuzzification technique. •Benchmarking confirm that the proposed method is feasible for criticality analysis in FPFTA. -- Abstract: Fuzzy probability – based fault tree analysis (FPFTA) has been recently developed and proposed to deal with the limitations of conventional fault tree analysis. In FPFTA, reliabilities of basic events, intermediate events and top event are characterized by fuzzy probabilities. Furthermore, the quantification of the FPFTA is based on fuzzy multiplication rule and fuzzy complementation rule to propagate uncertainties from basic event to the top event. Since the objective of the fault tree analysis is to improve the reliability of the system being evaluated, it is necessary to find the weakest path in the system. For this purpose, criticality analysis can be implemented. Various importance measures, which are based on conventional probabilities, have been developed and proposed for criticality analysis in fault tree analysis. However, not one of those importance measures can be applied for criticality analysis in FPFTA, which is based on fuzzy probability. To be fully applied in nuclear power plant probabilistic safety assessment, FPFTA needs to have its corresponding importance measure. The objective of this study is to develop an α-cut method based importance measure to evaluate and rank the importance of basic events for criticality analysis in FPFTA. To demonstrate the applicability of the proposed measure, a case study is performed and its results are then benchmarked to the results generated by the four well known importance measures in conventional fault tree analysis. The results

  13. Rich Interfaces for Dependability: Compositional Methods for Dynamic Fault Trees and Arcade models

    NARCIS (Netherlands)

    Boudali, H.; Crouzen, Pepijn; Haverkort, Boudewijn R.H.M.; Kuntz, G.W.M.; Stoelinga, Mariëlle Ida Antoinette

    This paper discusses two behavioural interfaces for reliability analysis: dynamic fault trees, which model the system reliability in terms of the reliability of its components and Arcade, which models the system reliability at an architectural level. For both formalisms, the reliability is analyzed

  14. Quantitative analysis of a fault tree with priority AND gates

    International Nuclear Information System (INIS)

    Yuge, T.; Yanagi, S.

    2008-01-01

    A method for calculating the exact top event probability of a fault tree with priority AND gates and repeated basic events is proposed when the minimal cut sets are given. A priority AND gate is an AND gate where the input events must occur in a prescribed order for the occurrence of the output event. It is known that the top event probability of such a dynamic fault tree is obtained by converting the tree into an equivalent Markov model. However, this method is not realistic for a complex system model because the number of states which should be considered in the Markov analysis increases explosively as the number of basic events increases. To overcome the shortcomings of the Markov model, we propose an alternative method to obtain the top event probability in this paper. We assume that the basic events occur independently, exponentially distributed, and the component whose failure corresponds to the occurrence of the basic event is non-repairable. First, we obtain the probability of occurrence of the output event of a single priority AND gate by Markov analysis. Then, the top event probability is given by a cut set approach and the inclusion-exclusion formula. An efficient procedure to obtain the probabilities corresponding to logical products in the inclusion-exclusion formula is proposed. The logical product which is composed of two or more priority AND gates having at least one common basic event as their inputs is transformed into the sum of disjoint events which are equivalent to a priority AND gate in the procedure. Numerical examples show that our method works well for complex systems

  15. Application fo fault tree methodology in the risk analysis of complex systems

    International Nuclear Information System (INIS)

    Vasconcelos, V. de.

    1984-01-01

    This study intends to describe the fault tree methodology and apply it to risk assessment of complex facilities. In the methodology description, it has been attempted to provide all the pertinent basic information, pointing out its more important aspects like, for instance, fault tree construction, evaluation techniques and their use in risk and reliability assessment of a system. In view of their importance, topics like common mode failures, human errors, data bases used in the calculations, and uncertainty evaluation of the results, will be discussed separately, each one in a chapter. For the purpose of applying the methodology, it was necessary to implement computer codes normally used for this kind of analysis. The computer codes PREP, KITT and SAMPLE, written in FORTRAN IV, were chosen, due to their availability and to the fact that they have been used in important studies of the nuclear area, like Wash-1400. With these codes, the probability of occurence of excessive pressure in the main system of the component test loop - CTC, of CDTN, was evaluated. (Author) [pt

  16. Method of reliability allocation based on fault tree analysis and fuzzy math in nuclear power plants

    International Nuclear Information System (INIS)

    Chen Zhaobing; Deng Jian; Cao Xuewu

    2005-01-01

    Reliability allocation is a kind of a difficult multi-objective optimization problem. It can not only be applied to determine the reliability characteristic of reactor systems, subsystem and main components but also be performed to improve the design, operation and maintenance of nuclear plants. The fuzzy math known as one of the powerful tools for fuzzy optimization and the fault analysis deemed to be one of the effective methods of reliability analysis can be applied to the reliability allocation model so as to work out the problems of fuzzy characteristic of some factors and subsystem's choice respectively in this paper. Thus we develop a failure rate allocation model on the basis of the fault tree analysis and fuzzy math. For the choice of the reliability constraint factors, we choose the six important ones according to practical need for conducting the reliability allocation. The subsystem selected by the top-level fault tree analysis is to avoid allocating reliability for all the equipment and components including the unnecessary parts. During the reliability process, some factors can be calculated or measured quantitatively while others only can be assessed qualitatively by the expert rating method. So we adopt fuzzy decision and dualistic contrast to realize the reliability allocation with the help of fault tree analysis. Finally the example of the emergency diesel generator's reliability allocation is used to illustrate reliability allocation model and improve this model simple and applicable. (authors)

  17. A fuzzy-based reliability approach to evaluate basic events of fault tree analysis for nuclear power plant probabilistic safety assessment

    International Nuclear Information System (INIS)

    Purba, Julwan Hendry

    2014-01-01

    Highlights: • We propose a fuzzy-based reliability approach to evaluate basic event reliabilities. • It implements the concepts of failure possibilities and fuzzy sets. • Experts evaluate basic event failure possibilities using qualitative words. • Triangular fuzzy numbers mathematically represent qualitative failure possibilities. • It is a very good alternative for conventional reliability approach. - Abstract: Fault tree analysis has been widely utilized as a tool for nuclear power plant probabilistic safety assessment. This analysis can be completed only if all basic events of the system fault tree have their quantitative failure rates or failure probabilities. However, it is difficult to obtain those failure data due to insufficient data, environment changing or new components. This study proposes a fuzzy-based reliability approach to evaluate basic events of system fault trees whose failure precise probability distributions of their lifetime to failures are not available. It applies the concept of failure possibilities to qualitatively evaluate basic events and the concept of fuzzy sets to quantitatively represent the corresponding failure possibilities. To demonstrate the feasibility and the effectiveness of the proposed approach, the actual basic event failure probabilities collected from the operational experiences of the David–Besse design of the Babcock and Wilcox reactor protection system fault tree are used to benchmark the failure probabilities generated by the proposed approach. The results confirm that the proposed fuzzy-based reliability approach arises as a suitable alternative for the conventional probabilistic reliability approach when basic events do not have the corresponding quantitative historical failure data for determining their reliability characteristics. Hence, it overcomes the limitation of the conventional fault tree analysis for nuclear power plant probabilistic safety assessment

  18. RADYBAN: A tool for reliability analysis of dynamic fault trees through conversion into dynamic Bayesian networks

    International Nuclear Information System (INIS)

    Montani, S.; Portinale, L.; Bobbio, A.; Codetta-Raiteri, D.

    2008-01-01

    In this paper, we present RADYBAN (Reliability Analysis with DYnamic BAyesian Networks), a software tool which allows to analyze a dynamic fault tree relying on its conversion into a dynamic Bayesian network. The tool implements a modular algorithm for automatically translating a dynamic fault tree into the corresponding dynamic Bayesian network and exploits classical algorithms for the inference on dynamic Bayesian networks, in order to compute reliability measures. After having described the basic features of the tool, we show how it operates on a real world example and we compare the unreliability results it generates with those returned by other methodologies, in order to verify the correctness and the consistency of the results obtained

  19. Power system reliability analysis using fault trees

    International Nuclear Information System (INIS)

    Volkanovski, A.; Cepin, M.; Mavko, B.

    2006-01-01

    The power system reliability analysis method is developed from the aspect of reliable delivery of electrical energy to customers. The method is developed based on the fault tree analysis, which is widely applied in the Probabilistic Safety Assessment (PSA). The method is adapted for the power system reliability analysis. The method is developed in a way that only the basic reliability parameters of the analysed power system are necessary as an input for the calculation of reliability indices of the system. The modeling and analysis was performed on an example power system consisting of eight substations. The results include the level of reliability of current power system configuration, the combinations of component failures resulting in a failed power delivery to loads, and the importance factors for components and subsystems. (author)

  20. Selection the Optimum Suppliers Compound Using a Mixed Model of MADM and Fault Tree Analysis

    Directory of Open Access Journals (Sweden)

    Meysam Azimian

    2017-03-01

    Full Text Available In this paper, an integrated approach of MADM and fault tree analysis (FTA is provided for determining the most reliable combination of suppliers for a strategic product in IUT University. At first, risks of suppliers is estimated by defining the indices for evaluating them, determining their relative status indices and using satisfying and SAW methods. Then, intrinsic risks of utilized equipments in the products are qualified and the final integrated risk for equipments is determined. Finally, through all the different scenarios, the best composition of equipment suppliers is selected by defining the palpable top events and fault tree analysis. The contribution of this paper is about proposing an integrated method of MADM and FTA to determine the most reliable suppliers in order to minimize the final risk of providing a product.

  1. Making systems with mutually exclusive events analysable by standard fault tree analysis tools

    International Nuclear Information System (INIS)

    Vaurio, J.K.

    2001-01-01

    Methods are developed for analysing systems that comprise mutually exclusive events by fault tree techniques that accept only statistically independent basic events. Techniques based on equivalent models and numerical transformations are presented for phased missions and for systems with component-caused system-level common cause failures. Numerical examples illustrate the methods

  2. Support vector machine in machine condition monitoring and fault diagnosis

    Science.gov (United States)

    Widodo, Achmad; Yang, Bo-Suk

    2007-08-01

    Recently, the issue of machine condition monitoring and fault diagnosis as a part of maintenance system became global due to the potential advantages to be gained from reduced maintenance costs, improved productivity and increased machine availability. This paper presents a survey of machine condition monitoring and fault diagnosis using support vector machine (SVM). It attempts to summarize and review the recent research and developments of SVM in machine condition monitoring and diagnosis. Numerous methods have been developed based on intelligent systems such as artificial neural network, fuzzy expert system, condition-based reasoning, random forest, etc. However, the use of SVM for machine condition monitoring and fault diagnosis is still rare. SVM has excellent performance in generalization so it can produce high accuracy in classification for machine condition monitoring and diagnosis. Until 2006, the use of SVM in machine condition monitoring and fault diagnosis is tending to develop towards expertise orientation and problem-oriented domain. Finally, the ability to continually change and obtain a novel idea for machine condition monitoring and fault diagnosis using SVM will be future works.

  3. Fault tolerance of the NIF power conditioning system

    International Nuclear Information System (INIS)

    Larson, D.W.; Anderson, R.; Boyes, J.

    1995-01-01

    The tolerance of the circuit topology proposed for the National Ignition Facility (NIF) power conditioning system to specific fault conditions is investigated. A new pulsed power circuit is proposed for the NIF which is simpler and less expensive than previous ICF systems. The inherent fault modes of the new circuit are different from the conventional approach, and must be understood to ensure adequate NIF system reliability. A test-bed which simulates the NIF capacitor module design was constructed to study the circuit design. Measurements from test-bed experiments with induced faults are compared with results from a detailed circuit model. The model is validated by the measurements and used to predict the behavior of the actual NIF module during faults. The model can be used to optimize fault tolerance of the NIF module through an appropriate distribution of circuit inductance and resistance. The experimental and modeling results are presented, and fault performance is compared with the ratings of pulsed power components. Areas are identified which require additional investigation

  4. The fault tree as a tool in safety analysis in nuclear power plants

    International Nuclear Information System (INIS)

    Waddington, J.G.; Wild, A.

    1981-01-01

    Modern safety analysis must be able to identify realistic failure modes based on realistic operation and system malfunction, demonstrate rigorously that adequate independence exists between a malfunctioning system and those other systems required to mitigate the effects of the malfunction, design adequate reliability into systems important to plant safety and to demonstrate rigorously that the design reliability is met in operation, and identify the realistic actions expected of the operator. Fault trees, which have proved to be a powerful tool to achieve these objectives, are inevitably large and must be computerized. However, the computerized system must be simple, must allow merging of branches developed independently, must provide for easy modification and the processing must be economical and easily accessible. A new system for displaying, plotting and analysing fault trees has been developed and implemented on a small computer at AECB to demonstrate the viability of the approach to designers, and to provide a tool to assess licensee's submissions on failure modes of support systems such as electrical, service water and air, and to assess reliability predictions for special safety systems. (author)

  5. Interactive system design using the complementarity of axiomatic design and fault tree analysis

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Do, Sung Hee; Lee, Tae Sik

    2007-01-01

    To efficiently design safety-critical systems such as nuclear power plants, with requirement of high reliability, methodologies allowing for rigorous interactions between the synthesis and analysis processes have been proposed. This paper attempts to develop a reliability-centered design framework through an interactive process between Axiomatic Design (AD) and Fault Tree Analysis (FTA). Integrating AD and FTA into a single framework appears to be a viable solution, as they compliment each other with their unique advantages. AD provides a systematic synthesis tool while FTA is commonly used as a safety analysis tool. These methodologies build a design process that is less subjective, and they enable designers to develop insights that lead to solutions with improved reliability. Due to the nature of the two methodologies, the information involved in each process is complementary: a success tree versus a fault tree. Thus, at each step a system using AD is synthesized, and its reliability is then quantified using the FT derived from the AD synthesis process. The converted FT provides an opportunity to examine the completeness of the outcome from the synthesis process. This study presents an example of the design of a Containment Heat Removal System (CHRS). A case study illustrates the process of designing the CHRS with an interactive design framework focusing on the conversion of the AD process to FTA

  6. Application of fault tree analysis for customer reliability assessment of a distribution power system

    International Nuclear Information System (INIS)

    Abdul Rahman, Fariz; Varuttamaseni, Athi; Kintner-Meyer, Michael; Lee, John C.

    2013-01-01

    A new method is developed for predicting customer reliability of a distribution power system using the fault tree approach with customer weighted values of component failure frequencies and downtimes. Conventional customer reliability prediction of the electric grid employs the system average (SA) component failure frequency and downtime that are weighted by only the quantity of the components in the system. These SA parameters are then used to calculate the reliability and availability of components in the system, and eventually to find the effect on customer reliability. Although this approach is intuitive, information is lost regarding customer disturbance experiences when customer information is not utilized in the SA parameter calculations, contributing to inaccuracies when predicting customer reliability indices in our study. Hence our new approach directly incorporates customer disturbance information in component failure frequency and downtime calculations by weighting these parameters with information of customer interruptions. This customer weighted (CW) approach significantly improves the prediction of customer reliability indices when applied to our reliability model with fault tree and two-state Markov chain formulations. Our method has been successfully applied to an actual distribution power system that serves over 2.1 million customers. Our results show an improved benchmarking performance on the system average interruption frequency index (SAIFI) by 26% between the SA-based and CW-based reliability calculations. - Highlights: ► We model the reliability of a power system with fault tree and two-state Markov chain. ► We propose using customer weighted component failure frequencies and downtimes. ► Results show customer weighted values perform superior to component average values. ► This method successfully incorporates customer disturbance information into the model.

  7. The completeness of fault tree analysis in the presence of dependencies

    International Nuclear Information System (INIS)

    Hughes, R.P.

    1989-02-01

    Existing standard fault tree assessments of systems do not include an assessment of the effects of dependencies in an integrated fashion, but simply add on a ''common cause cut-off''. To support the values used for this cut-off, cut-sets involving certain groups of components susceptible to dependent failure can be assessed using the Distributed Failure Probability method. These rank one contributions do not cover all the possibilities, however, so there is an outstanding need for an integrated procedure for dependent failure assessment of systems which allows for all ranks of cut-set. The purpose of this note is to provide such a procedure which builds upon the standard approach to fault tree analysis. In this standard approach, only a limited number of cut-sets is found, and they are evaluated assuming independence of their components. So, some cut-sets are neglected which could be important contributors to the system failure probability if their components are not independent of each other. The procedure developed therefore deals with this truncation problem and with dependency together. The result is a practical and efficient method for bounding system failure probabilities. The method is a progressive one, whereby this bound is reduced as necessary by a more refined analysis. A simple example is used to illustrate the procedure. (author)

  8. A systematic fault tree analysis based on multi-level flow modeling

    International Nuclear Information System (INIS)

    Gofuku, Akio; Ohara, Ai

    2010-01-01

    The fault tree analysis (FTA) is widely applied for the safety evaluation of a large-scale and mission-critical system. Because the potential of the FTA, however, strongly depends on human skill of analyzers, problems are pointed out in (1) education and training, (2) unreliable quality, (3) necessity of expertise knowledge, and (4) update of FTA results after the reconstruction of a target system. To get rid of these problems, many techniques to systematize FTA activities by applying computer technologies have been proposed. However, these techniques only use structural information of a target system and do not use functional information that is one of important properties of an artifact. The principle of FTA is to trace comprehensively cause-effect relations from a top undesirable effect to anomaly causes. The tracing is similar to the causality estimation technique that the authors proposed to find plausible counter actions to prevent or to mitigate the undesirable behavior of plants based on the model by a functional modeling technique, Multilevel Flow Modeling (MFM). The authors have extended this systematic technique to construct a fault tree (FT). This paper presents an algorithm of systematic construction of FT based on MFM models and demonstrates the applicability of the extended technique by the FT construction result of a cooling plant of nitric acid. (author)

  9. Fault tree and failure mode and effects analysis of a digital safety function

    International Nuclear Information System (INIS)

    Maskuniitty, M.; Pulkkinen, U.

    1995-01-01

    The principles of fault tree and failure mode and effects analysis (FMEA) for the analysis of digital safety functions of nuclear power plants are discussed. Based on experiences from a case study, a proposal for a full scale analysis is presented. The feasibility and applicability the above mentioned reliability engineering methods are discussed. (author). 13 refs, 1 fig., 2 tabs

  10. Validation of Helicopter Gear Condition Indicators Using Seeded Fault Tests

    Science.gov (United States)

    Dempsey, Paula; Brandon, E. Bruce

    2013-01-01

    A "seeded fault test" in support of a rotorcraft condition based maintenance program (CBM), is an experiment in which a component is tested with a known fault while health monitoring data is collected. These tests are performed at operating conditions comparable to operating conditions the component would be exposed to while installed on the aircraft. Performance of seeded fault tests is one method used to provide evidence that a Health Usage Monitoring System (HUMS) can replace current maintenance practices required for aircraft airworthiness. Actual in-service experience of the HUMS detecting a component fault is another validation method. This paper will discuss a hybrid validation approach that combines in service-data with seeded fault tests. For this approach, existing in-service HUMS flight data from a naturally occurring component fault will be used to define a component seeded fault test. An example, using spiral bevel gears as the targeted component, will be presented. Since the U.S. Army has begun to develop standards for using seeded fault tests for HUMS validation, the hybrid approach will be mapped to the steps defined within their Aeronautical Design Standard Handbook for CBM. This paper will step through their defined processes, and identify additional steps that may be required when using component test rig fault tests to demonstrate helicopter CI performance. The discussion within this paper will provide the reader with a better appreciation for the challenges faced when defining a seeded fault test for HUMS validation.

  11. Fault Tree Analysis for Safety/Security Verification in Aviation Software

    Directory of Open Access Journals (Sweden)

    Andrew J. Kornecki

    2013-01-01

    Full Text Available The Next Generation Air Traffic Management system (NextGen is a blueprint of the future National Airspace System. Supporting NextGen is a nation-wide Aviation Simulation Network (ASN, which allows integration of a variety of real-time simulations to facilitate development and validation of the NextGen software by simulating a wide range of operational scenarios. The ASN system is an environment, including both simulated and human-in-the-loop real-life components (pilots and air traffic controllers. Real Time Distributed Simulation (RTDS developed at Embry Riddle Aeronautical University, a suite of applications providing low and medium fidelity en-route simulation capabilities, is one of the simulations contributing to the ASN. To support the interconnectivity with the ASN, we designed and implemented a dedicated gateway acting as an intermediary, providing logic for two-way communication and transfer messages between RTDS and ASN and storage for the exchanged data. It has been necessary to develop and analyze safety/security requirements for the gateway software based on analysis of system assets, hazards, threats and attacks related to ultimate real-life future implementation. Due to the nature of the system, the focus was placed on communication security and the related safety of the impacted aircraft in the simulation scenario. To support development of safety/security requirements, a well-established fault tree analysis technique was used. This fault tree model-based analysis, supported by a commercial tool, was a foundation to propose mitigations assuring the gateway system safety and security. 

  12. Waste Management Fault Tree Data Bank (WM): 1992 status report

    International Nuclear Information System (INIS)

    Baughman, D.F.; Hang, P.; Townsend, C.S.

    1993-01-01

    The Risk Assessment Methodology Group (RAM) of the Nuclear Process Safety Research Section (NPSR) maintains a compilation of incidents that have occurred in the Waste Management facilities. The Waste Management Fault Tree Data Bank (WM) contains more than 35,000 entries ranging from minor equipment malfunctions to incidents with significant potential for injury or contamination of personnel. This report documents the status of the WM data bank including: availability, training, source of data, search options, and usage, to which these data have been applied. Periodic updates to this memorandum are planned as additional data or applications are acquired

  13. Algorithm for finding minimal cut sets in a fault tree

    International Nuclear Information System (INIS)

    Rosenberg, Ladislav

    1996-01-01

    This paper presents several algorithms that have been used in a computer code for fault-tree analysing by the minimal cut sets method. The main algorithm is the more efficient version of the new CARA algorithm, which finds minimal cut sets with an auxiliary dynamical structure. The presented algorithm for finding the minimal cut sets enables one to do so by defined requirements - according to the order of minimal cut sets, or to the number of minimal cut sets, or both. This algorithm is from three to six times faster when compared with the primary version of the CARA algorithm

  14. Fault tree analysis on BWR core spray system

    International Nuclear Information System (INIS)

    Watanabe, Norio

    1982-06-01

    Fault Trees which describe the failure modes for the Core Spray System function in the Browns Ferry Nuclear Plant (BWR 1065MWe) were developed qualitatively and quantitatively. The unavailability for the Core Spray System was estimated to be 1.2 x 10 - 3 /demand. It was found that the miscalibration of four reactor pressure sensors or the failure to open of the two inboard valves (FCV 75-25 and 75-53) could reduce system reliability significantly. It was recommended that the pressure sensors would be calibrated independently. The introduction of the redundant inboard valves could improve the system reliability. Thus this analysis method was verified useful for system analysis. The detailed test and maintenance manual and the informations on the control logic circuits of each active component are necessary for further analysis. (author)

  15. Safety analyses of potential exposure in medical irradiation plants by Fuzzy Fault Tree

    International Nuclear Information System (INIS)

    Casamirra, Maddalena; Castiglia, Francesco; Giardina, Mariarosa; Tomarchio, Elio

    2008-01-01

    The results of Fuzzy Fault Tree (FFT) analyses of various accidental scenarios, which involve the operators in potential exposures inside an High Dose Rate (HDR) remote after-loading systems for use in brachytherapy, are reported. To carry out fault tree analyses by means of fuzzy probabilities, the TREEZZY2 computer code is used. Moreover, the HEART (Human Error Assessment and Reduction Technique) model, properly modified on the basis of the fuzzy approach, has been employed to assess the impact of performances haping and error-promoting factors in the context of the accidental events. The assessment of potential dose values for some identified accidental scenarios allows to consider, for a particular event, a fuzzy uncertainty range in potential dose estimate. The availability of lower and upper limits allows evaluating the possibility of optimization of the installation from the point of view of radiation protection. The adequacy of the training and information program for staff and patients (and their family members) and the effectiveness of behavioural rules and safety procedures were tested. Some recommendations on procedures and equipment to reduce the risk of radiological exposure are also provided. (author)

  16. Comparison of methods for uncertainty analysis of nuclear-power-plant safety-system fault-tree models

    International Nuclear Information System (INIS)

    Martz, H.F.; Beckman, R.J.; Campbell, K.; Whiteman, D.E.; Booker, J.M.

    1983-04-01

    A comparative evaluation is made of several methods for propagating uncertainties in actual coupled nuclear power plant safety system faults tree models. The methods considered are Monte Carlo simulation, the method of moments, a discrete distribution method, and a bootstrap method. The Monte Carlo method is found to be superior. The sensitivity of the system unavailability distribution to the choice of basic event unavailability distribution is also investigated. The system distribution is also investigated. The system distribution is especially sensitive to the choice of symmetric versus asymmetric basic event distributions. A quick-and dirty method for estimating percentiles of the system unavailability distribution is developed. The method identifies the appropriate basic event distribution percentiles that should be used in evaluating the Boolean system equivalent expression for a given fault tree model to arrive directly at the 5th, 10th, 50th, 90th, and 95th percentiles of the system unavailability distribution

  17. Reliability study of the auxiliary feed-water system of a pressurized water reactor by faults tree and Bayesian Network

    International Nuclear Information System (INIS)

    Lava, Deise Diana; Borges, Diogo da Silva; Guimarães, Antonio Cesar Ferreira; Moreira, Maria de Lourdes

    2017-01-01

    This paper aims to present a study of the reliability of the Auxiliary Feed-water System (AFWS) through the methods of Fault Tree and Bayesian Network. Therefore, the paper consists of a literature review of the history of nuclear energy and the methodologies used. The AFWS is responsible for providing water system to cool the secondary circuit of nuclear reactors of the PWR type when normal feeding water system failure. How this system operates only when the primary system fails, it is expected that the AFWS failure probability is very low. The AFWS failure probability is divided into two cases: the first is the probability of failure in the first eight hours of operation and the second is the probability of failure after eight hours of operation, considering that the system has not failed within the first eight hours. The calculation of the probability of failure of the second case was made through the use of Fault Tree and Bayesian Network, that it was constructed from the Fault Tree. The results of the failure probability obtained were very close, on the order of 10 -3 . (author)

  18. Reliability study of the auxiliary feed-water system of a pressurized water reactor by faults tree and Bayesian Network

    Energy Technology Data Exchange (ETDEWEB)

    Lava, Deise Diana; Borges, Diogo da Silva; Guimarães, Antonio Cesar Ferreira; Moreira, Maria de Lourdes, E-mail: deise_dy@hotmail.com, E-mail: diogosb@outlook.com, E-mail: tony@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    This paper aims to present a study of the reliability of the Auxiliary Feed-water System (AFWS) through the methods of Fault Tree and Bayesian Network. Therefore, the paper consists of a literature review of the history of nuclear energy and the methodologies used. The AFWS is responsible for providing water system to cool the secondary circuit of nuclear reactors of the PWR type when normal feeding water system failure. How this system operates only when the primary system fails, it is expected that the AFWS failure probability is very low. The AFWS failure probability is divided into two cases: the first is the probability of failure in the first eight hours of operation and the second is the probability of failure after eight hours of operation, considering that the system has not failed within the first eight hours. The calculation of the probability of failure of the second case was made through the use of Fault Tree and Bayesian Network, that it was constructed from the Fault Tree. The results of the failure probability obtained were very close, on the order of 10{sup -3}. (author)

  19. Fuzzy fault tree assessment based on improved AHP for fire and explosion accidents for steel oil storage tanks.

    Science.gov (United States)

    Shi, Lei; Shuai, Jian; Xu, Kui

    2014-08-15

    Fire and explosion accidents of steel oil storage tanks (FEASOST) occur occasionally during the petroleum and chemical industry production and storage processes and often have devastating impact on lives, the environment and property. To contribute towards the development of a quantitative approach for assessing the occurrence probability of FEASOST, a fault tree of FEASOST is constructed that identifies various potential causes. Traditional fault tree analysis (FTA) can achieve quantitative evaluation if the failure data of all of the basic events (BEs) are available, which is almost impossible due to the lack of detailed data, as well as other uncertainties. This paper makes an attempt to perform FTA of FEASOST by a hybrid application between an expert elicitation based improved analysis hierarchy process (AHP) and fuzzy set theory, and the occurrence possibility of FEASOST is estimated for an oil depot in China. A comparison between statistical data and calculated data using fuzzy fault tree analysis (FFTA) based on traditional and improved AHP is also made. Sensitivity and importance analysis has been performed to identify the most crucial BEs leading to FEASOST that will provide insights into how managers should focus effective mitigation. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Computer Simulation of Complex Power System Faults under various Operating Conditions

    International Nuclear Information System (INIS)

    Khandelwal, Tanuj; Bowman, Mark

    2015-01-01

    A power system is normally treated as a balanced symmetrical three-phase network. When a fault occurs, the symmetry is normally upset, resulting in unbalanced currents and voltages appearing in the network. For the correct application of protection equipment, it is essential to know the fault current distribution throughout the system and the voltages in different parts of the system due to the fault. There may be situations where protection engineers have to analyze faults that are more complex than simple shunt faults. One type of complex fault is an open phase condition that can result from a fallen conductor or failure of a breaker pole. In the former case, the condition is often accompanied by a fault detectable with normal relaying. In the latter case, the condition may be undetected by standard line relaying. The effect on a generator is dependent on the location of the open phase and the load level. If an open phase occurs between the generator terminals and the high-voltage side of the GSU in the switchyard, and the generator is at full load, damaging negative sequence current can be generated. However, for the same operating condition, an open conductor at the incoming transmission lines located in the switchyard can result in minimal negative sequence current. In 2012, a nuclear power generating station (NPGS) suffered series or open phase fault due to insulator mechanical failure in the 345 kV switchyard. This resulted in both reactor units tripping offline in two separate incidents. Series fault on one of the phases resulted in voltage imbalance that was not detected by the degraded voltage relays. These under-voltage relays did not initiate a start signal to the emergency diesel generators (EDG) because they sensed adequate voltage on the remaining phases exposing a design vulnerability. This paper is intended to help protection engineers calculate complex circuit faults like open phase condition using computer program. The impact of this type of

  1. Extreme hydrothermal conditions at an active plate-bounding fault

    Science.gov (United States)

    Sutherland, Rupert; Townend, John; Toy, Virginia; Upton, Phaedra; Coussens, Jamie; Allen, Michael; Baratin, Laura-May; Barth, Nicolas; Becroft, Leeza; Boese, Carolin; Boles, Austin; Boulton, Carolyn; Broderick, Neil G. R.; Janku-Capova, Lucie; Carpenter, Brett M.; Célérier, Bernard; Chamberlain, Calum; Cooper, Alan; Coutts, Ashley; Cox, Simon; Craw, Lisa; Doan, Mai-Linh; Eccles, Jennifer; Faulkner, Dan; Grieve, Jason; Grochowski, Julia; Gulley, Anton; Hartog, Arthur; Howarth, Jamie; Jacobs, Katrina; Jeppson, Tamara; Kato, Naoki; Keys, Steven; Kirilova, Martina; Kometani, Yusuke; Langridge, Rob; Lin, Weiren; Little, Timothy; Lukacs, Adrienn; Mallyon, Deirdre; Mariani, Elisabetta; Massiot, Cécile; Mathewson, Loren; Melosh, Ben; Menzies, Catriona; Moore, Jo; Morales, Luiz; Morgan, Chance; Mori, Hiroshi; Niemeijer, Andre; Nishikawa, Osamu; Prior, David; Sauer, Katrina; Savage, Martha; Schleicher, Anja; Schmitt, Douglas R.; Shigematsu, Norio; Taylor-Offord, Sam; Teagle, Damon; Tobin, Harold; Valdez, Robert; Weaver, Konrad; Wiersberg, Thomas; Williams, Jack; Woodman, Nick; Zimmer, Martin

    2017-06-01

    Temperature and fluid pressure conditions control rock deformation and mineralization on geological faults, and hence the distribution of earthquakes. Typical intraplate continental crust has hydrostatic fluid pressure and a near-surface thermal gradient of 31 ± 15 degrees Celsius per kilometre. At temperatures above 300-450 degrees Celsius, usually found at depths greater than 10-15 kilometres, the intra-crystalline plasticity of quartz and feldspar relieves stress by aseismic creep and earthquakes are infrequent. Hydrothermal conditions control the stability of mineral phases and hence frictional-mechanical processes associated with earthquake rupture cycles, but there are few temperature and fluid pressure data from active plate-bounding faults. Here we report results from a borehole drilled into the upper part of the Alpine Fault, which is late in its cycle of stress accumulation and expected to rupture in a magnitude 8 earthquake in the coming decades. The borehole (depth 893 metres) revealed a pore fluid pressure gradient exceeding 9 ± 1 per cent above hydrostatic levels and an average geothermal gradient of 125 ± 55 degrees Celsius per kilometre within the hanging wall of the fault. These extreme hydrothermal conditions result from rapid fault movement, which transports rock and heat from depth, and topographically driven fluid movement that concentrates heat into valleys. Shear heating may occur within the fault but is not required to explain our observations. Our data and models show that highly anomalous fluid pressure and temperature gradients in the upper part of the seismogenic zone can be created by positive feedbacks between processes of fault slip, rock fracturing and alteration, and landscape development at plate-bounding faults.

  2. Extreme hydrothermal conditions at an active plate-bounding fault.

    Science.gov (United States)

    Sutherland, Rupert; Townend, John; Toy, Virginia; Upton, Phaedra; Coussens, Jamie; Allen, Michael; Baratin, Laura-May; Barth, Nicolas; Becroft, Leeza; Boese, Carolin; Boles, Austin; Boulton, Carolyn; Broderick, Neil G R; Janku-Capova, Lucie; Carpenter, Brett M; Célérier, Bernard; Chamberlain, Calum; Cooper, Alan; Coutts, Ashley; Cox, Simon; Craw, Lisa; Doan, Mai-Linh; Eccles, Jennifer; Faulkner, Dan; Grieve, Jason; Grochowski, Julia; Gulley, Anton; Hartog, Arthur; Howarth, Jamie; Jacobs, Katrina; Jeppson, Tamara; Kato, Naoki; Keys, Steven; Kirilova, Martina; Kometani, Yusuke; Langridge, Rob; Lin, Weiren; Little, Timothy; Lukacs, Adrienn; Mallyon, Deirdre; Mariani, Elisabetta; Massiot, Cécile; Mathewson, Loren; Melosh, Ben; Menzies, Catriona; Moore, Jo; Morales, Luiz; Morgan, Chance; Mori, Hiroshi; Niemeijer, Andre; Nishikawa, Osamu; Prior, David; Sauer, Katrina; Savage, Martha; Schleicher, Anja; Schmitt, Douglas R; Shigematsu, Norio; Taylor-Offord, Sam; Teagle, Damon; Tobin, Harold; Valdez, Robert; Weaver, Konrad; Wiersberg, Thomas; Williams, Jack; Woodman, Nick; Zimmer, Martin

    2017-06-01

    Temperature and fluid pressure conditions control rock deformation and mineralization on geological faults, and hence the distribution of earthquakes. Typical intraplate continental crust has hydrostatic fluid pressure and a near-surface thermal gradient of 31 ± 15 degrees Celsius per kilometre. At temperatures above 300-450 degrees Celsius, usually found at depths greater than 10-15 kilometres, the intra-crystalline plasticity of quartz and feldspar relieves stress by aseismic creep and earthquakes are infrequent. Hydrothermal conditions control the stability of mineral phases and hence frictional-mechanical processes associated with earthquake rupture cycles, but there are few temperature and fluid pressure data from active plate-bounding faults. Here we report results from a borehole drilled into the upper part of the Alpine Fault, which is late in its cycle of stress accumulation and expected to rupture in a magnitude 8 earthquake in the coming decades. The borehole (depth 893 metres) revealed a pore fluid pressure gradient exceeding 9 ± 1 per cent above hydrostatic levels and an average geothermal gradient of 125 ± 55 degrees Celsius per kilometre within the hanging wall of the fault. These extreme hydrothermal conditions result from rapid fault movement, which transports rock and heat from depth, and topographically driven fluid movement that concentrates heat into valleys. Shear heating may occur within the fault but is not required to explain our observations. Our data and models show that highly anomalous fluid pressure and temperature gradients in the upper part of the seismogenic zone can be created by positive feedbacks between processes of fault slip, rock fracturing and alteration, and landscape development at plate-bounding faults.

  3. Stochastic Model Predictive Fault Tolerant Control Based on Conditional Value at Risk for Wind Energy Conversion System

    Directory of Open Access Journals (Sweden)

    Yun-Tao Shi

    2018-01-01

    Full Text Available Wind energy has been drawing considerable attention in recent years. However, due to the random nature of wind and high failure rate of wind energy conversion systems (WECSs, how to implement fault-tolerant WECS control is becoming a significant issue. This paper addresses the fault-tolerant control problem of a WECS with a probable actuator fault. A new stochastic model predictive control (SMPC fault-tolerant controller with the Conditional Value at Risk (CVaR objective function is proposed in this paper. First, the Markov jump linear model is used to describe the WECS dynamics, which are affected by many stochastic factors, like the wind. The Markov jump linear model can precisely model the random WECS properties. Second, the scenario-based SMPC is used as the controller to address the control problem of the WECS. With this controller, all the possible realizations of the disturbance in prediction horizon are enumerated by scenario trees so that an uncertain SMPC problem can be transformed into a deterministic model predictive control (MPC problem. Finally, the CVaR object function is adopted to improve the fault-tolerant control performance of the SMPC controller. CVaR can provide a balance between the performance and random failure risks of the system. The Min-Max performance index is introduced to compare the fault-tolerant control performance with the proposed controller. The comparison results show that the proposed method has better fault-tolerant control performance.

  4. 42 CFR 411.53 - Basis for conditional Medicare payment in no-fault cases.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Basis for conditional Medicare payment in no-fault... Limitations on Medicare Payment for Services Covered Under Liability or No-Fault Insurance § 411.53 Basis for conditional Medicare payment in no-fault cases. (a) A conditional Medicare payment may be made in no-fault...

  5. Analytical solutions of linked fault tree probabilistic risk assessments using binary decision diagrams with emphasis on nuclear safety applications

    International Nuclear Information System (INIS)

    Nusbaumer, O. P. M.

    2007-01-01

    This study is concerned with the quantification of Probabilistic Risk Assessment (PRA) using linked Fault Tree (FT) models. Probabilistic Risk assessment (PRA) of Nuclear Power Plants (NPPs) complements traditional deterministic analysis; it is widely recognized as a comprehensive and structured approach to identify accident scenarios and to derive numerical estimates of the associated risk levels. PRA models as found in the nuclear industry have evolved rapidly. Increasingly, they have been broadly applied to support numerous applications on various operational and regulatory matters. Regulatory bodies in many countries require that a PRA be performed for licensing purposes. PRA has reached the point where it can considerably influence the design and operation of nuclear power plants. However, most of the tools available for quantifying large PRA models are unable to produce analytically correct results. The algorithms of such quantifiers are designed to neglect sequences when their likelihood decreases below a predefined cutoff limit. In addition, the rare event approximation (e.g. Moivre's equation) is typically implemented for the first order, ignoring the success paths and the possibility that two or more events can occur simultaneously. This is only justified in assessments where the probabilities of the basic events are low. When the events in question are failures, the first order rare event approximation is always conservative, resulting in wrong interpretation of risk importance measures. Advanced NPP PRA models typically include human errors, common cause failure groups, seismic and phenomenological basic events, where the failure probabilities may approach unity, leading to questionable results. It is accepted that current quantification tools have reached their limits, and that new quantification techniques should be investigated. A novel approach using the mathematical concept of Binary Decision Diagram (BDD) is proposed to overcome these deficiencies

  6. Digraph-fault tree methodology for the assessment of material control systems

    International Nuclear Information System (INIS)

    Lambert, H.E.; Lim, J.J.; Gilman, F.M.

    1979-01-01

    The Lawrence Livermore Laboratory, under contract to the United States Nuclear Regulatory Commission, is developing a procedure to assess the effectiveness of material control and accounting systems at nuclear fuel cycle facilities. The purpose of a material control and accounting system is to prevent the theft of special nuclear material such as plutonium or highly enriched uranium. This report presents the use of a directed graph and fault tree analysis methodology in the assessment procedure. This methodology is demonstrated by assessing a simulated material control system design, the Test Bed

  7. Fault tree and reliability relationships for analyzing noncoherent two-state systems

    International Nuclear Information System (INIS)

    Alesso, H.P.; Benson, H.J.

    1980-01-01

    Recently, there has been interest in analyzing the noncoherent interactions that result from adversary theft of special nuclear material from reprocessing facilities. The actions of the adversary, acting in conflict with the reprocessing facility's material control and accounting system, may be viewed as a single noncoherent structure. This paper develops a basis for analyzing noncoherent structures by decomposing them into coherent subsystems. Both reliability and fault tree structure functions are used for this analysis. In addition, a bounding criterion is established for the reliability of statistically dependent noncoherent structures. (orig.)

  8. How to avoid the generation of logic loops in the construction of fault trees

    International Nuclear Information System (INIS)

    Demichela, M.; Piccinini, N.; Ciarambino, I.; Contini, S.

    2004-01-01

    Generation of an infinite series of identical sub-trees may occur during the construction of a Fault Tree (FT) when one item of equipment in a plant is considered several times in the same sub-tree in the course of the tree extraction from a HazOp (Hazard Operability analysis) analysis. Generation of loops in the construction of an FT can be avoided by means of an ad hoc logical analysis in which certain simple rules of syntax are taken into account. A radical solution, however, can be obtained if identification of unwanted events in a process plant is not undertaken with conventional procedures, such as HazOp (Operability Analysis with guide words, failure mode and effect analysis (FMEA) etc.), but with a more modern and structured version, such as Recursive Operability Analysis (ROA), which is both systematic and complete, and allows direct extraction of logic trees, (FT, event trees, etc.) for subsequent quantification. This feature means that, by contrast with conventional operability analysis, the congruence of the ROA itself can be checked. The ROA method is illustrated in this paper with the aid of some simple examples

  9. Study of the Atucha I nuclear power plant's residual heat removal system unavailability through the fault tree analysis and common cause failures

    International Nuclear Information System (INIS)

    Terrado, C.A.

    1991-06-01

    The present essay offers a comprehensive research of the Atucha I nuclear power plant's residual heat removal system unavailability, including Fault Tree Analysis and Common Cause Failures (CCF) treatment. The study is developed within the Event Tree perspective that considers the loss of external electrical power of the initiating event. The event was constructed by the Safety Evaluations Division of the Ezeiza Atomic Center in Argentina. According to the Event Tree, the research includes system demand during plant operation with 132 KV and emergency generation (Diesel motor generators). The system unavailability assessment is approached in two different ways: a) Considering independent failures only. b) Taking into account the existence of Common Cause Events, and modeling dependent failures. The Fault Tree quantification is played using the AIEA PSAPACK Code. The assessment data base is compiled from plant specific records and generic data bases like TECDOC 478. After Fault Tree model logic development, some general procedures used in common cause failures treating are applied to pick up another set of solutions. The results of the study are: a) Four Fault Trees have been developed to model the abovementioned system: 132 KV and emergency generation, both including and excluding CCF. b) The following unavailability values were obtained: 132 KV independent failures only: 7 10 -4 . Emergency generation independent failures only: 1.53 10 -2 . 132 KV dependent and independent failures: 3.6 10 -3 . Emergency generation dependent and independent failures: 1.74 10 -2 . The major conclusions obtained from the precedent results are: a) When using 132 KV system configuration, minimal cut sets involving common cause failures represents 81%from total system unavailability. b) The dependent failures treatment is an important task to be considered in safety assessments in order to reach more realistic values. (Author) [es

  10. Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line

    Science.gov (United States)

    Malla, S. G.; Bhende, C. N.

    2014-10-01

    The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.

  11. Incipient Fault Detection for Rolling Element Bearings under Varying Speed Conditions.

    Science.gov (United States)

    Xue, Lang; Li, Naipeng; Lei, Yaguo; Li, Ningbo

    2017-06-20

    Varying speed conditions bring a huge challenge to incipient fault detection of rolling element bearings because both the change of speed and faults could lead to the amplitude fluctuation of vibration signals. Effective detection methods need to be developed to eliminate the influence of speed variation. This paper proposes an incipient fault detection method for bearings under varying speed conditions. Firstly, relative residual (RR) features are extracted, which are insensitive to the varying speed conditions and are able to reflect the degradation trend of bearings. Then, a health indicator named selected negative log-likelihood probability (SNLLP) is constructed to fuse a feature set including RR features and non-dimensional features. Finally, based on the constructed SNLLP health indicator, a novel alarm trigger mechanism is designed to detect the incipient fault. The proposed method is demonstrated using vibration signals from bearing tests and industrial wind turbines. The results verify the effectiveness of the proposed method for incipient fault detection of rolling element bearings under varying speed conditions.

  12. PC-based support programs coupled with the sets code for large fault tree analysis

    International Nuclear Information System (INIS)

    Hioki, K.; Nakai, R.

    1989-01-01

    Power Reactor and Nuclear Fuel Development Corporation (PNC) has developed four PC programs: IEIQ (Initiating Event Identification and Quantification), MODESTY (Modular Even Description for a Variety of Systems), FAUST (Fault Summary Tables Generation Program) and ETAAS (Event Tree Analysis Assistant System). These programs prepare the input data for the SETS (Set Equation Transformation System) code and construct and quantify event trees (E/Ts) using the output of the SETS code. The capability of these programs is described and some examples of the results are presented in this paper. With these PC programs and the SETS code, PSA can now be performed with more consistency and less manpower

  13. Electric machines modeling, condition monitoring, and fault diagnosis

    CERN Document Server

    Toliyat, Hamid A; Choi, Seungdeog; Meshgin-Kelk, Homayoun

    2012-01-01

    With countless electric motors being used in daily life, in everything from transportation and medical treatment to military operation and communication, unexpected failures can lead to the loss of valuable human life or a costly standstill in industry. To prevent this, it is important to precisely detect or continuously monitor the working condition of a motor. Electric Machines: Modeling, Condition Monitoring, and Fault Diagnosis reviews diagnosis technologies and provides an application guide for readers who want to research, develop, and implement a more effective fault diagnosis and condi

  14. Reactor internals design/analysis for normal, upset, and faulted conditions

    International Nuclear Information System (INIS)

    Burke, F.R.

    1977-06-01

    The analytical procedures used by Babcock and Wilcox to demonstrate the structural integrity of the 205-FA reactor internals are described. Analytical results are presented and compared to ASME Code allowable limits for Normal, Upset, and Faulted conditions. The particular faulted condition considered is a simultaneous loss-of-coolant accident and safe shutdown earthquake. The operating basis earthquake is addressed as an Upset condition

  15. Detection of Partial Demagnetization Fault in PMSMs Operating under Nonstationary Conditions

    DEFF Research Database (Denmark)

    Wang, Chao; Delgado Prieto, Miguel; Romeral, Luis

    2016-01-01

    Demagnetization fault detection of in-service Permanent Magnet Synchronous Machines (PMSMs) is a challenging task because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman F......Demagnetization fault detection of in-service Permanent Magnet Synchronous Machines (PMSMs) is a challenging task because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold......-Kalman Filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. Amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on partial demagnetization online fault...... detection of PMSMs under various speed and load conditions....

  16. Fault tree analysis: A survey of the state-of-the-art in modeling, analysis and tools

    NARCIS (Netherlands)

    Ruijters, Enno Jozef Johannes; Stoelinga, Mariëlle Ida Antoinette

    2015-01-01

    Fault tree analysis (FTA) is a very prominent method to analyze the risks related to safety and economically critical assets, like power plants, airplanes, data centers and web shops. FTA methods comprise of a wide variety of modelling and analysis techniques, supported by a wide range of software

  17. Fault Tree Analysis: A survey of the state-of-the-art in modeling, analysis and tools

    NARCIS (Netherlands)

    Ruijters, Enno Jozef Johannes; Stoelinga, Mariëlle Ida Antoinette

    2014-01-01

    Fault tree analysis (FTA) is a very prominent method to analyze the risks related to safety and economically critical assets, like power plants, airplanes, data centers and web shops. FTA methods comprise of a wide variety of modelling and analysis techniques, supported by a wide range of software

  18. Incipient Fault Detection for Rolling Element Bearings under Varying Speed Conditions

    Directory of Open Access Journals (Sweden)

    Lang Xue

    2017-06-01

    Full Text Available Varying speed conditions bring a huge challenge to incipient fault detection of rolling element bearings because both the change of speed and faults could lead to the amplitude fluctuation of vibration signals. Effective detection methods need to be developed to eliminate the influence of speed variation. This paper proposes an incipient fault detection method for bearings under varying speed conditions. Firstly, relative residual (RR features are extracted, which are insensitive to the varying speed conditions and are able to reflect the degradation trend of bearings. Then, a health indicator named selected negative log-likelihood probability (SNLLP is constructed to fuse a feature set including RR features and non-dimensional features. Finally, based on the constructed SNLLP health indicator, a novel alarm trigger mechanism is designed to detect the incipient fault. The proposed method is demonstrated using vibration signals from bearing tests and industrial wind turbines. The results verify the effectiveness of the proposed method for incipient fault detection of rolling element bearings under varying speed conditions.

  19. Large-coil-test-facility fault-tree analysis

    International Nuclear Information System (INIS)

    1982-01-01

    An operating-safety study is being conducted for the Large Coil Test Facility (LCTF). The purpose of this study is to provide the facility operators and users with added insight into potential problem areas that could affect the safety of personnel or the availability of equipment. This is a preliminary report, on Phase I of that study. A central feature of the study is the incorporation of engineering judgements (by LCTF personnel) into an outside, overall view of the facility. The LCTF was analyzed in terms of 32 subsystems, each of which are subject to failure from any of 15 generic failure initiators. The study identified approximately 40 primary areas of concern which were subjected to a computer analysis as an aid in understanding the complex subsystem interactions that can occur within the facility. The study did not analyze in detail the internal structure of the subsystems at the individual component level. A companion study using traditional fault tree techniques did analyze approximately 20% of the LCTF at the component level. A comparison between these two analysis techniques is included in Section 7

  20. Application of fault tree analysis to fuel cell diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Yousfi Steiner, N.; Mocoteguy, P. [European Institute for Energy Research (EIFER), Karlsruhe (Germany); Hissel, D. [FEMTO-ST/ENISYS/FC LAB, UMR CNRS 6174, University of Franche-Comte, Belfort (France); Candusso, D. [IFSTTAR/FC LAB, Institute of Science and Technology for Transport, Development and Networks, Belfort (France); Marra, D.; Pianese, C.; Sorrentino, M. [Department of Industrial Engineering, University of Salerno, Fisciano (Italy)

    2012-04-15

    Reliability and lifetime are common issues for the development and commercialization of fuel cells technologies'. As a consequence, their improvement is a major challenge and the last decade has experienced a growing interest in activities that aims at understanding the degradation mechanisms and at developing fuel cell systems diagnosis tools. Fault Tree Analysis (FTA) is one of the deductive tools that allow ''linking'' an undesired state to a combination of lower-level events via a ''top-down'' approach which is mainly used in safety and reliability engineering. The objective of this paper is to give an overview of the use and the contribution of FTA to both SOFC and PEFC diagnosis. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. The Development of a Fault Tree Model for Balance of Plant System

    International Nuclear Information System (INIS)

    Hwang, Mee Jeong; Park, Jin Hee; Lim, Ho Gon

    2011-01-01

    In this paper, we propose a fault tree modeling method for BOP (balance of plant) system to develop a combined risk model and trip model, and the application plans of the developed model. Where, the trip means the reactor trip and turbine and generator trip. We have usually modeled the safety-related systems and their supporting systems to assess the risk analysis of a nuclear power plant. However, the BOP system.s condition change induces the risk change. That is, the BOP system.s condition is relevant to plants. performance and affects to the plant risk. The existing model for BOP systems is a simplified system model or SPV (Single-point vulnerability) evaluation model. However, these models are not effective enough to use for the plant's performance evaluation. Also, lately an integrated decision-making framework is required for risk-informed applications. The methods for monitoring the performance of a nuclear power plant differ from the purpose. For example, MSPI (mitigating system performance index) and MR (maintenance rule) use different methods and indexes to monitor the performance. Therefore, for consistent decision-making, it is necessary to develop a risk assessment model including a systems model inducing reactor trip. The system.s model inducing reactor trip and turbine/generator trip is defined as the 'trip model'

  2. Comparison between state graphs and fault trees for sequential and repairable systems

    International Nuclear Information System (INIS)

    Soussan, D.; Saignes, P.

    1996-01-01

    In French PSA (Probabilistic Safety Assessment) 1300 for the 1300 Mwe PWR plants carried out by EDF, sequential and reparable systems are modeled with state graphs. This method is particularly convenient for modeling dynamic systems with long-term missions but induces a bad traceability and understandability of models. In the objective of providing elements for rewriting PSA 1300 with only boolean models, EDF has asked CEA to participate to a methodological study. The aim is to carry out a feasibility study of transposition of state graphs models into fault trees on Component Cooling System and Essential Service Water System (CCS/ESWS) and to draw a methodological guide for transposition. The study realized on CCS/ESWS involves two main axes: quantification of cold source loss (as an accident sequence initiating event, called H1); quantification of the CCS/ESWS missions in accident sequences. The subject of this article is to show that this transformation is applicable with minimum distortions of the results and to determine the hypotheses, the conditions and the limits of application of this conversion. (authors). 2 refs

  3. A general method dealing with correlations in uncertainty propagation in fault trees

    International Nuclear Information System (INIS)

    Qin Zhang

    1989-01-01

    This paper deals with the correlations among the failure probabilities (frequencies) of not only the identical basic events but also other basic events in a fault tree. It presents a general and simple method to include these correlations in uncertainty propagation. Two examples illustrate this method and show that neglecting these correlations results in large underestimation of the top event failure probability (frequency). One is the failure of the primary pump in a chemical reactor cooling system, the other example is an accident to a road transport truck carrying toxic waste. (author)

  4. A fuzzy decision tree method for fault classification in the steam generator of a pressurized water reactor

    International Nuclear Information System (INIS)

    Zio, Enrico; Baraldi, Piero; Popescu, Irina Crenguta

    2009-01-01

    This paper extends a method previously introduced by the authors for building a transparent fault classification algorithm by combining the fuzzy clustering, fuzzy logic and decision trees techniques. The baseline method transforms an opaque, fuzzy clustering-based classification model into a fuzzy logic inference model based on linguistic rules which can be represented by a decision tree formalism. The classification model thereby obtained is transparent in that it allows direct interpretation and inspection of the model. An extension in the procedure for the development of the fuzzy logic inference model is introduced to allow the treatment of more complicated cases, e.g. splitted and overlapping clusters. The corresponding computational tool developed relies on a number of parameters which can be tuned by the user to optimally compromise the level of transparency of the classification process and its efficiency. A numerical application is presented with regards to the fault classification in the Steam Generator of a Pressurized Water Reactor.

  5. Analytical solutions of linked fault tree probabilistic risk assessments using binary decision diagrams with emphasis on nuclear safety applications[Dissertation 17286

    Energy Technology Data Exchange (ETDEWEB)

    Nusbaumer, O. P. M

    2007-07-01

    This study is concerned with the quantification of Probabilistic Risk Assessment (PRA) using linked Fault Tree (FT) models. Probabilistic Risk assessment (PRA) of Nuclear Power Plants (NPPs) complements traditional deterministic analysis; it is widely recognized as a comprehensive and structured approach to identify accident scenarios and to derive numerical estimates of the associated risk levels. PRA models as found in the nuclear industry have evolved rapidly. Increasingly, they have been broadly applied to support numerous applications on various operational and regulatory matters. Regulatory bodies in many countries require that a PRA be performed for licensing purposes. PRA has reached the point where it can considerably influence the design and operation of nuclear power plants. However, most of the tools available for quantifying large PRA models are unable to produce analytically correct results. The algorithms of such quantifiers are designed to neglect sequences when their likelihood decreases below a predefined cutoff limit. In addition, the rare event approximation (e.g. Moivre's equation) is typically implemented for the first order, ignoring the success paths and the possibility that two or more events can occur simultaneously. This is only justified in assessments where the probabilities of the basic events are low. When the events in question are failures, the first order rare event approximation is always conservative, resulting in wrong interpretation of risk importance measures. Advanced NPP PRA models typically include human errors, common cause failure groups, seismic and phenomenological basic events, where the failure probabilities may approach unity, leading to questionable results. It is accepted that current quantification tools have reached their limits, and that new quantification techniques should be investigated. A novel approach using the mathematical concept of Binary Decision Diagram (BDD) is proposed to overcome these

  6. Presentation of common cause failures in fault tree structure of Krsko PSA : an historical overview

    International Nuclear Information System (INIS)

    Vrbanic, I.; Kosutic, I.; Vukovic, I.; Simic, Z.

    2003-01-01

    Failure of multiple components due to a common cause represents one of the most important issues in evaluation of system reliability or unavailability. The frequency of such events has relatively low expectancy, when compared to random failures, which affect individual components. However, in many cases the consequence is a direct loss of safety system or mitigative safety function. For this reason, the modeling of a common cause failure (CCF) and its presentation in fault tree structure is of the uttermost importance in probabilistic safety analyses (PSA). During the past decade, PSA model of Krsko NPP has undergone many small changes and a couple of major ones in fulfilling its basic purpose, which was serving as a tool for providing an appropriate information on the risk associated with actual plant design and operation. All changes to Krsko PSA model were undertaken in order to make it a better tool and / or to make it represent the plant in more accurate manner. The paper provides an overview of changes in CCF modeling in the fault tree structure from the initial PSA model development till present. (author)

  7. Study of the reliability of the Auxiliary Feedwater System of a LWR nuclear power plant through the Fault Tree and Bayesian Network

    International Nuclear Information System (INIS)

    Lava, Deise Diana

    2016-01-01

    This paper aims to present a study of the reliability of the Auxiliary Feedwater System (AFWS) through the methods of Fault Tree and Bayesian Network. Therefore, the paper consists of a literature review of the history of nuclear energy and the methodologies used. The AFWS is responsible for providing water system to cool the secondary circuit of nuclear reactors of the PWR type when normal feeding water system failure. How this system operates only when the primary system fails, it is expected that the AFWS failure probability is very low. The AFWS failure probability is divided into two cases: the first is the probability of failure in the first eight hours of operation and the second is the probability of failure after eight hours of operation, considering that the system has not failed within the first eight hours. The calculation of the probability of failure of the second case was made through the use of Fault Tree and Bayesian Network, that it was constructed from the Fault Tree. The results of the failure probability obtained were very close, on the order of 10 -3 . (author)

  8. Fault diagnosis of air conditioning systems based on qualitative bond graph

    International Nuclear Information System (INIS)

    Ghiaus, C.

    1999-01-01

    The bond graph method represents a unified approach for modeling engineering systems. The main idea is that power transfer bonds the components of a system. The bond graph model is the same for both quantitative representation, in which parameters have numerical values, and qualitative approach, in which they are classified qualitatively. To infer the cause of faults using a qualitative method, a system of qualitative equations must be solved. However, the characteristics of qualitative operators require specific methods for solving systems of equations having qualitative variables. This paper proposes both a method for recursively solving the qualitative system of equations derived from bond graph, and a bond graph model of a direct-expansion, mechanical vapor-compression air conditioning system. Results from diagnosing two faults in a real air conditioning system are presented and discussed. Occasionally, more than one fault candidate is inferred for the same set of qualitative values derived from measurements. In these cases, additional information is required to localize the fault. Fault diagnosis is initiated by a fault detection mechanism which also classifies the quantitative measurements into qualitative values; the fault detection is not presented here. (author)

  9. Efficient algorithms to assess component and gate importance in fault tree analysis

    International Nuclear Information System (INIS)

    Dutuit, Y.; Rauzy, A.

    2001-01-01

    One of the principal activities of risk assessment is either the ranking or the categorization of structures, systems and components with respect to their risk-significance or their safety-significance. Several measures, so-called importance factors, of such a significance have been proposed for the case where the support model is a fault tree. In this article, we show how binary decision diagrams can be use to assess efficiently a number of classical importance factors. This work completes the preliminary results obtained recently by Andrews and Sinnamon, and the authors. It deals also with the concept of joint reliability importance

  10. Study on conditional probability of surface rupture: effect of fault dip and width of seismogenic layer

    Science.gov (United States)

    Inoue, N.

    2017-12-01

    The conditional probability of surface ruptures is affected by various factors, such as shallow material properties, process of earthquakes, ground motions and so on. Toda (2013) pointed out difference of the conditional probability of strike and reverse fault by considering the fault dip and width of seismogenic layer. This study evaluated conditional probability of surface rupture based on following procedures. Fault geometry was determined from the randomly generated magnitude based on The Headquarters for Earthquake Research Promotion (2017) method. If the defined fault plane was not saturated in the assumed width of the seismogenic layer, the fault plane depth was randomly provided within the seismogenic layer. The logistic analysis was performed to two data sets: surface displacement calculated by dislocation methods (Wang et al., 2003) from the defined source fault, the depth of top of the defined source fault. The estimated conditional probability from surface displacement indicated higher probability of reverse faults than that of strike faults, and this result coincides to previous similar studies (i.e. Kagawa et al., 2004; Kataoka and Kusakabe, 2005). On the contrary, the probability estimated from the depth of the source fault indicated higher probability of thrust faults than that of strike and reverse faults, and this trend is similar to the conditional probability of PFDHA results (Youngs et al., 2003; Moss and Ross, 2011). The probability of combined simulated results of thrust and reverse also shows low probability. The worldwide compiled reverse fault data include low fault dip angle earthquake. On the other hand, in the case of Japanese reverse fault, there is possibility that the conditional probability of reverse faults with less low dip angle earthquake shows low probability and indicates similar probability of strike fault (i.e. Takao et al., 2013). In the future, numerical simulation by considering failure condition of surface by the source

  11. Investigating Strain Transfer Along the Southern San Andreas Fault: A Geomorphic and Geodetic Study of Block Rotation in the Eastern Transverse Ranges, Joshua Tree National Park, CA

    Science.gov (United States)

    Guns, K. A.; Bennett, R. A.; Blisniuk, K.

    2017-12-01

    To better evaluate the distribution and transfer of strain and slip along the Southern San Andreas Fault (SSAF) zone in the northern Coachella valley in southern California, we integrate geological and geodetic observations to test whether strain is being transferred away from the SSAF system towards the Eastern California Shear Zone through microblock rotation of the Eastern Transverse Ranges (ETR). The faults of the ETR consist of five east-west trending left lateral strike slip faults that have measured cumulative offsets of up to 20 km and as low as 1 km. Present kinematic and block models present a variety of slip rate estimates, from as low as zero to as high as 7 mm/yr, suggesting a gap in our understanding of what role these faults play in the larger system. To determine whether present-day block rotation along these faults is contributing to strain transfer in the region, we are applying 10Be surface exposure dating methods to observed offset channel and alluvial fan deposits in order to estimate fault slip rates along two faults in the ETR. We present observations of offset geomorphic landforms using field mapping and LiDAR data at three sites along the Blue Cut Fault and one site along the Smoke Tree Wash Fault in Joshua Tree National Park which indicate recent Quaternary fault activity. Initial results of site mapping and clast count analyses reveal at least three stages of offset, including potential Holocene offsets, for one site along the Blue Cut Fault, while preliminary 10Be geochronology is in progress. This geologic slip rate data, combined with our new geodetic surface velocity field derived from updated campaign-based GPS measurements within Joshua Tree National Park will allow us to construct a suite of elastic fault block models to elucidate rates of strain transfer away from the SSAF and how that strain transfer may be affecting the length of the interseismic period along the SSAF.

  12. Failure analysis of storage tank component in LNG regasification unit using fault tree analysis method (FTA)

    Science.gov (United States)

    Mulyana, Cukup; Muhammad, Fajar; Saad, Aswad H.; Mariah, Riveli, Nowo

    2017-03-01

    Storage tank component is the most critical component in LNG regasification terminal. It has the risk of failure and accident which impacts to human health and environment. Risk assessment is conducted to detect and reduce the risk of failure in storage tank. The aim of this research is determining and calculating the probability of failure in regasification unit of LNG. In this case, the failure is caused by Boiling Liquid Expanding Vapor Explosion (BLEVE) and jet fire in LNG storage tank component. The failure probability can be determined by using Fault Tree Analysis (FTA). Besides that, the impact of heat radiation which is generated is calculated. Fault tree for BLEVE and jet fire on storage tank component has been determined and obtained with the value of failure probability for BLEVE of 5.63 × 10-19 and for jet fire of 9.57 × 10-3. The value of failure probability for jet fire is high enough and need to be reduced by customizing PID scheme of regasification LNG unit in pipeline number 1312 and unit 1. The value of failure probability after customization has been obtained of 4.22 × 10-6.

  13. A novel method of fuzzy fault tree analysis combined with VB program to identify and assess the risk of coal dust explosions.

    Directory of Open Access Journals (Sweden)

    Hetang Wang

    Full Text Available Coal dust explosions (CDE are one of the main threats to the occupational safety of coal miners. Aiming to identify and assess the risk of CDE, this paper proposes a novel method of fuzzy fault tree analysis combined with the Visual Basic (VB program. In this methodology, various potential causes of the CDE are identified and a CDE fault tree is constructed. To overcome drawbacks from the lack of exact probability data for the basic events, fuzzy set theory is employed and the probability data of each basic event is treated as intuitionistic trapezoidal fuzzy numbers. In addition, a new approach for calculating the weighting of each expert is also introduced in this paper to reduce the error during the expert elicitation process. Specifically, an in-depth quantitative analysis of the fuzzy fault tree, such as the importance measure of the basic events and the cut sets, and the CDE occurrence probability is given to assess the explosion risk and acquire more details of the CDE. The VB program is applied to simplify the analysis process. A case study and analysis is provided to illustrate the effectiveness of this proposed method, and some suggestions are given to take preventive measures in advance and avoid CDE accidents.

  14. Failure mode analysis using state variables derived from fault trees with application

    International Nuclear Information System (INIS)

    Bartholomew, R.J.

    1982-01-01

    Fault Tree Analysis (FTA) is used extensively to assess both the qualitative and quantitative reliability of engineered nuclear power systems employing many subsystems and components. FTA is very useful, but the method is limited by its inability to account for failure mode rate-of-change interdependencies (coupling) of statistically independent failure modes. The state variable approach (using FTA-derived failure modes as states) overcomes these difficulties and is applied to the determination of the lifetime distribution function for a heat pipe-thermoelectric nuclear power subsystem. Analyses are made using both Monte Carlo and deterministic methods and compared with a Markov model of the same subsystem

  15. Fault Diagnosis for Rolling Bearings under Variable Conditions Based on Visual Cognition.

    Science.gov (United States)

    Cheng, Yujie; Zhou, Bo; Lu, Chen; Yang, Chao

    2017-05-25

    Fault diagnosis for rolling bearings has attracted increasing attention in recent years. However, few studies have focused on fault diagnosis for rolling bearings under variable conditions. This paper introduces a fault diagnosis method for rolling bearings under variable conditions based on visual cognition. The proposed method includes the following steps. First, the vibration signal data are transformed into a recurrence plot (RP), which is a two-dimensional image. Then, inspired by the visual invariance characteristic of the human visual system (HVS), we utilize speed up robust feature to extract fault features from the two-dimensional RP and generate a 64-dimensional feature vector, which is invariant to image translation, rotation, scaling variation, etc. Third, based on the manifold perception characteristic of HVS, isometric mapping, a manifold learning method that can reflect the intrinsic manifold embedded in the high-dimensional space, is employed to obtain a low-dimensional feature vector. Finally, a classical classification method, support vector machine, is utilized to realize fault diagnosis. Verification data were collected from Case Western Reserve University Bearing Data Center, and the experimental result indicates that the proposed fault diagnosis method based on visual cognition is highly effective for rolling bearings under variable conditions, thus providing a promising approach from the cognitive computing field.

  16. Enterprise architecture availability analysis using fault trees and stakeholder interviews

    Science.gov (United States)

    Närman, Per; Franke, Ulrik; König, Johan; Buschle, Markus; Ekstedt, Mathias

    2014-01-01

    The availability of enterprise information systems is a key concern for many organisations. This article describes a method for availability analysis based on Fault Tree Analysis and constructs from the ArchiMate enterprise architecture (EA) language. To test the quality of the method, several case-studies within the banking and electrical utility industries were performed. Input data were collected through stakeholder interviews. The results from the case studies were compared with availability of log data to determine the accuracy of the method's predictions. In the five cases where accurate log data were available, the yearly downtime estimates were within eight hours from the actual downtimes. The cost of performing the analysis was low; no case study required more than 20 man-hours of work, making the method ideal for practitioners with an interest in obtaining rapid availability estimates of their enterprise information systems.

  17. Geological conditions for lateral sealing of active faults and relevant research methods

    Directory of Open Access Journals (Sweden)

    Guang Fu

    2017-01-01

    Full Text Available Many researchers worked a lot on geologic conditions for lateral sealing of faults, but none of their studies took the effect of internal structures of fault zones on the lateral sealing capacity of faults. Therefore, the lateral sealing of active faults has rarely been discussed. In this paper, based on the analysis of the composition and structure characteristics of fault fillings, the geological conditions for lateral sealing of active faults and relevant research method were discussed in reference to the lateral sealing mechanisms of inactive fault rocks. It is shown that, in order to satisfy geologically the lateral sealing of active faults, the faults should be antithetic and the faulted strata should be mainly composed of mudstone, so that the displacement pressure of fault fillings is higher than or equal to that of reservoir rocks in oil and gas migration block. Then, a research method for the lateral sealing of active faults was established by comparing the displacement pressure of fillings in the fault with that of reservoir rocks in oil and gas migration block. This method was applied to three antithetic faults (F1, F2 and F3 in No. 1 structure of the Nanpu Sag, Bohai Bay Basin. As revealed, the fillings of these three active faults were mostly argillaceous at the stage of natural gas accumulation (the late stage of Neogene Minghuazhen Fm sedimentation, and their displacement pressures were higher than that of reservoir rocks in the first member of Paleogene Dongying Fm (F1 and F3 and the Neogene Guantao Fm (F2. Accordingly, they are laterally sealed for natural gas, which is conducive to the accumulation and preservation of natural gas. Industrial gas flow has been produced from the first member of Paleogene Dongying Fm in Well Np101, the Guantao Fm in Well Np1-2 and the first member of Paleogene Dongying Fm in Well Np1, which is in agreement with the analysis result. It is verified that this method is feasible for investigating the

  18. Calculating Nuclear Power Plant Vulnerability Using Integrated Geometry and Event/Fault-Tree Models

    International Nuclear Information System (INIS)

    Peplow, Douglas E.; Sulfredge, C. David; Sanders, Robert L.; Morris, Robert H.; Hann, Todd A.

    2004-01-01

    Since the events of September 11, 2001, the vulnerability of nuclear power plants to terrorist attacks has become a national concern. The results of vulnerability analysis are greatly influenced by the computational approaches used. Standard approximations used in fault-tree analysis are not applicable for attacks, where high component failure probabilities are expected; two methods that do work with high failure probabilities are presented. Different blast modeling approaches can also affect the end results. Modeling the structural details of facility buildings and the geometric layout of components within the buildings is required to yield meaningful results

  19. Material control study: a directed graph and fault tree procedure for adversary event set generation

    International Nuclear Information System (INIS)

    Lambert, H.E.; Lim, J.J.; Gilman, F.M.

    1978-01-01

    In work for the United States Nuclear Regulatory Commission, Lawrence Livermore Laboratory is developing an assessment procedure to evaluate the effectiveness of a potential nuclear facility licensee's material control (MC) system. The purpose of an MC system is to prevent the theft of special nuclear material such as plutonium and highly enriched uranium. The key in the assessment procedure is the generation and analysis of the adversary event sets by a directed graph and fault-tree methodology

  20. Structural analyses of ITER toroidal field coils under fault conditions

    International Nuclear Information System (INIS)

    Jong, C.T.J.

    1992-04-01

    ITER (International Thermonuclear Experimental Reactor) is intended to be an experimental thermonuclear tokamak reactor testing the basic physics performance and technologies essential to future fusion reactors. The magnet system of ITER consists essentially of 4 sub-systems, i.e. toroidal field coils (TFCs), poloidal field coils (PFCs), power supplies, and cryogenic supplies. These subsystems do not contain significant radioactivity inventories, but the large energy inventory is a potential accident initiator. The aim of the structural analyses is to prevent accidents from propagating into vacuum vessel, tritium system and cooling system, which all contain significant amounts of radioactivity. As part of design process 3 conditions are defined for PF and TF coils, at which mechanical behaviour has to be analyzed in some detail, viz: normal operating conditions, upset conditions and fault conditions. This paper describes the work carried out by ECN to create a detailed finite element model of 16 TFCs as well as results of some fault condition analyses made with the model. Due to fault conditions, either electrical or mechanical, magnetic loading of TFCs becomes abnormal and further mechanical failure of parts of the overall structure might occur (e.g. failure of coil, gravitational supports, intercoil structure). The analyses performed consist of linear elastic stress analyses and electro-magneto-structural analyses (coupled field analyses). 8 refs.; 5 figs.; 5 tabs

  1. Testing digital safety system software with a testability measure based on a software fault tree

    International Nuclear Information System (INIS)

    Sohn, Se Do; Hyun Seong, Poong

    2006-01-01

    Using predeveloped software, a digital safety system is designed that meets the quality standards of a safety system. To demonstrate the quality, the design process and operating history of the product are reviewed along with configuration management practices. The application software of the safety system is developed in accordance with the planned life cycle. Testing, which is a major phase that takes a significant time in the overall life cycle, can be optimized if the testability of the software can be evaluated. The proposed testability measure of the software is based on the entropy of the importance of basic statements and the failure probability from a software fault tree. To calculate testability, a fault tree is used in the analysis of a source code. With a quantitative measure of testability, testing can be optimized. The proposed testability can also be used to demonstrate whether the test cases based on uniform partitions, such as branch coverage criteria, result in homogeneous partitions that is known to be more effective than random testing. In this paper, the testability measure is calculated for the modules of a nuclear power plant's safety software. The module testing with branch coverage criteria required fewer test cases if the module has higher testability. The result shows that the testability measure can be used to evaluate whether partitions have homogeneous characteristics

  2. Working Conditions-Aware Fault Injection Technique

    OpenAIRE

    Alouani , Ihsen; Niar , Smail; Jemai , Mohamed; Kuradi , Fadi; Abid , Mohamed

    2012-01-01

    International audience; With new integration rates, the circuits sensitivity to environmental and working conditions has increased dramatically. Thus, presenting reliable, less consuming energy and error resilient architectures is being one of the major problems to deal with. Besides, evaluating robustness and effectiveness of the proposed architectures is also an urgent need. In this paper, we present an extension of SimpleScalar simulation tool having the ability to inject faults in a given...

  3. Fault-tolerant architecture: Evaluation methodology

    International Nuclear Information System (INIS)

    Battle, R.E.; Kisner, R.A.

    1992-08-01

    The design and reliability of four fault-tolerant architectures that may be used in nuclear power plant control systems were evaluated. Two architectures are variations of triple-modular-redundant (TMR) systems, and two are variations of dual redundant systems. The evaluation includes a review of methods of implementing fault-tolerant control, the importance of automatic recovery from failures, methods of self-testing diagnostics, block diagrams of typical fault-tolerant controllers, review of fault-tolerant controllers operating in nuclear power plants, and fault tree reliability analyses of fault-tolerant systems

  4. Conception of Repairable Dynamic Fault Trees and resolution by the use of RAATSS, a Matlab® toolbox based on the ATS formalism

    International Nuclear Information System (INIS)

    Manno, G.; Chiacchio, F.; Compagno, L.; D'Urso, D.; Trapani, N.

    2014-01-01

    Dynamic Fault Tree (DFT) is a well-known stochastic technique for conducting reliability studies of complex systems. At the state of the art, existing tools (both academic and commercial) do not fully support DFT with repairable components and repeated events, lowering the penetration of this powerful technique in real industrial applications (e.g., industrial processes and plants, computer, electronic and network applications). One of the main reasons limiting the attractiveness of DFT is that, originally, DFTs were conceived without repairable components; only recently few related works have started to deal with a formal semantic, which would avoid undefined behavior and misinterpretation of DFT. Other researchers have tackled the problem by introducing extensions of the original Fault Trees (FTs) technique like Boolean Driven Markov Processes (BDMPs) and Generalized Fault Trees (GFTs). However, despite they consider repairable systems and repeated events, we have found that the introduction of a different formalism with more complex features has again limited the penetration of these powerful methods in real applications. The target of this work is the original DFT technique. Starting from the state of the art, a set of standardized rules that frame the behaviors of dynamic gates are designed and a well-defined semantic for repairable-DFT is drawn through the application of a novel formalism, the Adaptive Transitions System (ATS). The proposed theoretical framework is afterward used to code a software tool, RAATSS, for the resolution of extended, repairable-DFT. Moreover, this work introduces some novel concepts regarding the modeling of a system by a DFT and provides a basic hint of the ATS capabilities to describe interdependencies in complex system. - Highlights: • A semantic for Repairable Dynamic Fault Tree (RDFT) was conceived. • Practical motivation for the use of RDFT is presented. • The conception of failure gates for the computation of the

  5. Experience in PSA fault tree modularization at the ASCO NPP

    International Nuclear Information System (INIS)

    Nos Llorens, V.; Frances Urmeneta, M.; Fraig Sureda, J.

    1995-01-01

    Probabilistic Safety Analysis (PSA) is a basic tool in decision-making for the optimization of back fittings, procedures and maintenance practices. ASCO NPP PSA was developed with a high level of detail in the models. This required considerable computer resources (long running time) to carry out the quantification. The quantification time had therefore to be flexible to allow continuous evaluation of the impact on the estimation and reduction of risk in the plant, and also to facilitate post-PSA applications. The most suitable way of achieving this flexibility was by compacting and reducing the detailed fault trees of the project by means of a modularization process. The purpose of the paper is to present the practical experience acquired with modularization carried out in the UTE UNITEC-INYPSA-EMPRESARIOS AGRUPADOS framework and the method applied, the support computer programs devised and their degree of effectiveness. (Author)

  6. Reliability Evaluation Methodologies of Fault Tolerant Techniques of Digital I and C Systems in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Seong, Poong Hyun; Lee, Seung Jun

    2011-01-01

    Since the reactor protection system was replaced from analog to digital, digital reactor protection system has 4 redundant channels and each channel has several modules. It is necessary for various fault tolerant techniques to improve availability and reliability due to using complex components in DPPS. To use the digital system, it is necessary to improve the reliability and availability of a system through fault-tolerant techniques. Several researches make an effort to effects of fault tolerant techniques. However, the effects of fault tolerant techniques have not been properly considered yet in most fault tree models. Various fault-tolerant techniques, which used in digital system in NPPs, should reflect in fault tree analysis for getting lower system unavailability and more reliable PSA. When fault-tolerant techniques are modeled in fault tree, categorizing the module to detect by each fault tolerant techniques, fault coverage, detection period and the fault recovery should be considered. Further work will concentrate on various aspects for fault tree modeling. We will find other important factors, and found a new theory to construct the fault tree model

  7. Bearing Fault Classification Based on Conditional Random Field

    Directory of Open Access Journals (Sweden)

    Guofeng Wang

    2013-01-01

    Full Text Available Condition monitoring of rolling element bearing is paramount for predicting the lifetime and performing effective maintenance of the mechanical equipment. To overcome the drawbacks of the hidden Markov model (HMM and improve the diagnosis accuracy, conditional random field (CRF model based classifier is proposed. In this model, the feature vectors sequences and the fault categories are linked by an undirected graphical model in which their relationship is represented by a global conditional probability distribution. In comparison with the HMM, the main advantage of the CRF model is that it can depict the temporal dynamic information between the observation sequences and state sequences without assuming the independence of the input feature vectors. Therefore, the interrelationship between the adjacent observation vectors can also be depicted and integrated into the model, which makes the classifier more robust and accurate than the HMM. To evaluate the effectiveness of the proposed method, four kinds of bearing vibration signals which correspond to normal, inner race pit, outer race pit and roller pit respectively are collected from the test rig. And the CRF and HMM models are built respectively to perform fault classification by taking the sub band energy features of wavelet packet decomposition (WPD as the observation sequences. Moreover, K-fold cross validation method is adopted to improve the evaluation accuracy of the classifier. The analysis and comparison under different fold times show that the accuracy rate of classification using the CRF model is higher than the HMM. This method brings some new lights on the accurate classification of the bearing faults.

  8. A Novel Method of Fault Diagnosis for Rolling Bearing Based on Dual Tree Complex Wavelet Packet Transform and Improved Multiscale Permutation Entropy

    Directory of Open Access Journals (Sweden)

    Guiji Tang

    2016-01-01

    Full Text Available A novel method of fault diagnosis for rolling bearing, which combines the dual tree complex wavelet packet transform (DTCWPT, the improved multiscale permutation entropy (IMPE, and the linear local tangent space alignment (LLTSA with the extreme learning machine (ELM, is put forward in this paper. In this method, in order to effectively discover the underlying feature information, DTCWPT, which has the attractive properties as nearly shift invariance and reduced aliasing, is firstly utilized to decompose the original signal into a set of subband signals. Then, IMPE, which is designed to reduce the variability of entropy measures, is applied to characterize the properties of each obtained subband signal at different scales. Furthermore, the feature vectors are constructed by combining IMPE of each subband signal. After the feature vectors construction, LLTSA is employed to compress the high dimensional vectors of the training and the testing samples into the low dimensional vectors with better distinguishability. Finally, the ELM classifier is used to automatically accomplish the condition identification with the low dimensional feature vectors. The experimental data analysis results validate the effectiveness of the presented diagnosis method and demonstrate that this method can be applied to distinguish the different fault types and fault degrees of rolling bearings.

  9. Results of a directed graph and fault tree assessment of a MC and A system

    International Nuclear Information System (INIS)

    Gilman, F.M.; Lambert, H.E.; Lim, J.J.

    1978-01-01

    An assessment of the effectiveness of the Material Control and Accounting System (MC and A) in a hypothetical nuclear facility, the TEST BED is presented. The key in assessing the TEST BED is the generation of adversary event sets. The adversary event sets are generated and analyzed by a directed graph (digraph) and fault tree procedure. Although the TEST BED is a system hardened against SNM theft, the assessment of the TEST BED finds several major weaknesses, and also indicates possible modifications to correct these weaknesses

  10. BACFIRE, Minimal Cut Sets Common Cause Failure Fault Tree Analysis

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1983-01-01

    1 - Description of problem or function: BACFIRE, designed to aid in common cause failure analysis, searches among the basic events of a minimal cut set of the system logic model for common potential causes of failure. The potential cause of failure is called a qualitative failure characteristics. The algorithm searches qualitative failure characteristics (that are part of the program input) of the basic events contained in a set to find those characteristics common to all basic events. This search is repeated for all cut sets input to the program. Common cause failure analysis is thereby performed without inclusion of secondary failure in the system logic model. By using BACFIRE, a common cause failure analysis can be added to an existing system safety and reliability analysis. 2 - Method of solution: BACFIRE searches the qualitative failure characteristics of the basic events contained in the fault tree minimal cut set to find those characteristics common to all basic events by either of two criteria. The first criterion can be met if all the basic events in a minimal cut set are associated by a condition which alone may increase the probability of multiple component malfunction. The second criterion is met if all the basic events in a minimal cut set are susceptible to the same secondary failure cause and are located in the same domain for that cause of secondary failure. 3 - Restrictions on the complexity of the problem - Maxima of: 1001 secondary failure maps, 101 basic events, 10 cut sets

  11. Fault diagnosis methods for district heating substations

    Energy Technology Data Exchange (ETDEWEB)

    Pakanen, J.; Hyvaerinen, J.; Kuismin, J.; Ahonen, M. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1996-12-31

    A district heating substation is a demanding process for fault diagnosis. The process is nonlinear, load conditions of the district heating network change unpredictably and standard instrumentation is designed only for control and local monitoring purposes, not for automated diagnosis. Extra instrumentation means additional cost, which is usually not acceptable to consumers. That is why all conventional methods are not applicable in this environment. The paper presents five different approaches to fault diagnosis. While developing the methods, various kinds of pragmatic aspects and robustness had to be considered in order to achieve practical solutions. The presented methods are: classification of faults using performance indexing, static and physical modelling of process equipment, energy balance of the process, interactive fault tree reasoning and statistical tests. The methods are applied to a control valve, a heat excharger, a mud separating device and the whole process. The developed methods are verified in practice using simulation, simulation or field tests. (orig.) (25 refs.)

  12. Probability intervals for the top event unavailability of fault trees

    International Nuclear Information System (INIS)

    Lee, Y.T.; Apostolakis, G.E.

    1976-06-01

    The evaluation of probabilities of rare events is of major importance in the quantitative assessment of the risk from large technological systems. In particular, for nuclear power plants the complexity of the systems, their high reliability and the lack of significant statistical records have led to the extensive use of logic diagrams in the estimation of low probabilities. The estimation of probability intervals for the probability of existence of the top event of a fault tree is examined. Given the uncertainties of the primary input data, a method is described for the evaluation of the first four moments of the top event occurrence probability. These moments are then used to estimate confidence bounds by several approaches which are based on standard inequalities (e.g., Tchebycheff, Cantelli, etc.) or on empirical distributions (the Johnson family). Several examples indicate that the Johnson family of distributions yields results which are in good agreement with those produced by Monte Carlo simulation

  13. Skewed Binary Search Trees

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Moruz, Gabriel

    2006-01-01

    It is well-known that to minimize the number of comparisons a binary search tree should be perfectly balanced. Previous work has shown that a dominating factor over the running time for a search is the number of cache faults performed, and that an appropriate memory layout of a binary search tree...... can reduce the number of cache faults by several hundred percent. Motivated by the fact that during a search branching to the left or right at a node does not necessarily have the same cost, e.g. because of branch prediction schemes, we in this paper study the class of skewed binary search trees....... For all nodes in a skewed binary search tree the ratio between the size of the left subtree and the size of the tree is a fixed constant (a ratio of 1/2 gives perfect balanced trees). In this paper we present an experimental study of various memory layouts of static skewed binary search trees, where each...

  14. Timing analysis of safety properties using fault trees with time dependencies and timed state-charts

    International Nuclear Information System (INIS)

    Magott, Jan; Skrobanek, Pawel

    2012-01-01

    Behavior in time domain is often crucial for safety critical systems. Standard fault trees cannot express time-dependent behavior. In the paper, timing analysis of safety properties using fault trees with time dependencies (FTTDs) and timed state-charts is presented. A new version of timed state-charts (TSCs) is also proposed. These state-charts can model the dynamics of technical systems, e.g. controllers, controlled objects, and people. In TSCs, activity and communication times are represented by time intervals. In the proposed approach the structure of FTTD is fixed by a human. Time properties of events and gates of FTTD are expressed by time intervals, and are calculated using TSCs. The minimal and maximal values of these time intervals of FTTD can be calculated by finding paths with minimal and maximal time lengths in TSCs, which is an NP-hard problem. In order to reduce the practical complexity of computing the FTTD time parameters, some reductions of TSCs are defined in the paper, such as sequential, alternative, loop (iteration), and parallel. Some of the reductions are intuitive, in case of others—theorems are required. Computational complexity of each reduction is not greater than linear in the size of reduced TSC. Therefore, the obtained results enable decreasing of the costs of FTTD time parameters calculation when system dynamics is expressed by TSCs. Case study of a railroad crossing with a controller that controls semaphores, gate, light-audio signal close to the gate will be analyzed.

  15. A phase angle based diagnostic scheme to planetary gear faults diagnostics under non-stationary operational conditions

    Science.gov (United States)

    Feng, Ke; Wang, Kesheng; Ni, Qing; Zuo, Ming J.; Wei, Dongdong

    2017-11-01

    Planetary gearbox is a critical component for rotating machinery. It is widely used in wind turbines, aerospace and transmission systems in heavy industry. Thus, it is important to monitor planetary gearboxes, especially for fault diagnostics, during its operational conditions. However, in practice, operational conditions of planetary gearbox are often characterized by variations of rotational speeds and loads, which may bring difficulties for fault diagnosis through the measured vibrations. In this paper, phase angle data extracted from measured planetary gearbox vibrations is used for fault detection under non-stationary operational conditions. Together with sample entropy, fault diagnosis on planetary gearbox is implemented. The proposed scheme is explained and demonstrated in both simulation and experimental studies. The scheme proves to be effective and features advantages on fault diagnosis of planetary gearboxes under non-stationary operational conditions.

  16. Towards generating ECSS-compliant fault tree analysis results via ConcertoFLA

    Science.gov (United States)

    Gallina, B.; Haider, Z.; Carlsson, A.

    2018-05-01

    Attitude Control Systems (ACSs) maintain the orientation of the satellite in three-dimensional space. ACSs need to be engineered in compliance with ECSS standards and need to ensure a certain degree of dependability. Thus, dependability analysis is conducted at various levels and by using ECSS-compliant techniques. Fault Tree Analysis (FTA) is one of these techniques. FTA is being automated within various Model Driven Engineering (MDE)-based methodologies. The tool-supported CHESS-methodology is one of them. This methodology incorporates ConcertoFLA, a dependability analysis technique enabling failure behavior analysis and thus FTA-results generation. ConcertoFLA, however, similarly to other techniques, still belongs to the academic research niche. To promote this technique within the space industry, we apply it on an ACS and discuss about its multi-faceted potentialities in the context of ECSS-compliant engineering.

  17. The effects of urban warming on herbivore abundance and street tree condition.

    Directory of Open Access Journals (Sweden)

    Adam G Dale

    Full Text Available Trees are essential to urban habitats because they provide services that benefit the environment and improve human health. Unfortunately, urban trees often have more herbivorous insect pests than rural trees but the mechanisms and consequences of these infestations are not well documented. Here, we examine how temperature affects the abundance of a scale insect, Melanaspis tenebricosa (Comstock (Hemiptera: Diaspididae, on one of the most commonly planted street trees in the eastern U.S. Next, we examine how both pest abundance and temperature are associated with water stress, growth, and condition of 26 urban street trees. Although trees in the warmest urban sites grew the most, they were more water stressed and in worse condition than trees in cooler sites. Our analyses indicate that visible declines in tree condition were best explained by scale-insect infestation rather than temperature. To test the broader relevance of these results, we extend our analysis to a database of more than 2700 Raleigh, US street trees. Plotting these trees on a Landsat thermal image of Raleigh, we found that warmer sites had over 70% more trees in poor condition than those in cooler sites. Our results support previous studies linking warmer urban habitats to greater pest abundance and extend this association to show its effect on street tree condition. Our results suggest that street tree condition and ecosystem services may decline as urban expansion and global warming exacerbate the urban heat island effect. Although our non-probability sampling method limits our scope of inference, our results present a gloomy outlook for urban forests and emphasize the need for management tools. Existing urban tree inventories and thermal maps could be used to identify species that would be most suitable for urban conditions.

  18. Fault condition recognition of rolling bearing in bridge crane based on PSO–KPCA

    Directory of Open Access Journals (Sweden)

    He Yan

    2017-01-01

    Full Text Available When the rolling bearing in bridge crane gets out of order and often accompanies with occurrence of nonlinear behaviours, its fault information is weak and it is difficult to extract fault features and to distinguish diverse failure modes. Kernel principal component analysis (KPCA may realize nonlinear mapping to solve nonlinear problems. In the paper the particle swarm optimization (PSO)is applied to optimization of kernel function parameter to reduce its bind set-up. The optimal mathematical model of kernel parameters is constructed by means of thought of fisher discriminate functions .And then it is used to bridge crane rolling bearing simulated faults recognition. The simulation results show that KPCA optimized by PSO can effectively classify fault conditions of rolling bearing. It can be concluded that non-linear mapping capability of KPCA after its function parameter by PSO is greatly improved and the KPCA-PSO is very suit for slight and incipient mechanical fault condition recognition.

  19. Modeling of a Switched Reluctance Motor under Stator Winding Fault Condition

    DEFF Research Database (Denmark)

    Chen, Hao; Han, G.; Yan, Wei

    2016-01-01

    A new method for modeling stator winding fault with one shorted coil in a switched reluctance motor (SRM) is presented in this paper. The method is based on artificial neural network (ANN), incorporated with a simple analytical model in electromagnetic analysis to estimate the flux-linkage charac......A new method for modeling stator winding fault with one shorted coil in a switched reluctance motor (SRM) is presented in this paper. The method is based on artificial neural network (ANN), incorporated with a simple analytical model in electromagnetic analysis to estimate the flux......-linkage characteristics of SRM under the stator winding fault. The magnetic equivalent circuit method with ANN is applied to calculate the nonlinear flux-linkage characteristics under stator winding fault condition. A stator winding fault 12/8 SRM prototype system is developed to verify the effectiveness of the proposed...... method. The results for a stator winding fault with one shorted coil are obtained from the proposed method and from the experimental work on a developed prototype. It is shown that the simulation results are close to the test results....

  20. Public transport risk assessment through fault tree analysis

    Directory of Open Access Journals (Sweden)

    Z. Yaghoubpour

    2016-04-01

    Full Text Available This study focused on the public transport risk assessment in District one of ​​Tehran through Fault Tree Analysis involving the three criteria of human, vehicle and road in Haddon matrix. In fact, it examined the factors contributing to the occurrence of road accidents at several urban black spots within District 1. Relying on road safety checklists and survey of experts, this study made an effort to help urban managers to assess the risks in the public transport and prevent road accidents. Finally, the risk identification and assessment of public transport in District one yielded several results to answer the research questions. The hypotheses analysis suggested that safety issues involved in public transport are concerned by urban managers. The key reactive measures are investigation of accidents, identification of causes and correction of black spots. In addition to high costs, however, the reactive measures give rise to multiple operational problems such as traffic navigation and guaranteeing user safety in every operation. The case study highlighted the same fact. The macro-level management in the metropolis of Tehran is critical. The urban road casualties and losses can be curtailed by preventive measures such as continuous assessment of road safety.

  1. Modeling and Analysis of Component Faults and Reliability

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Ravn, Anders Peter

    2016-01-01

    This chapter presents a process to design and validate models of reactive systems in the form of communicating timed automata. The models are extended with faults associated with probabilities of occurrence. This enables a fault tree analysis of the system using minimal cut sets that are automati......This chapter presents a process to design and validate models of reactive systems in the form of communicating timed automata. The models are extended with faults associated with probabilities of occurrence. This enables a fault tree analysis of the system using minimal cut sets...... that are automatically generated. The stochastic information on the faults is used to estimate the reliability of the fault affected system. The reliability is given with respect to properties of the system state space. We illustrate the process on a concrete example using the Uppaal model checker for validating...... the ideal system model and the fault modeling. Then the statistical version of the tool, UppaalSMC, is used to find reliability estimates....

  2. Assurance of Fault Management: Risk-Significant Adverse Condition Awareness

    Science.gov (United States)

    Fitz, Rhonda

    2016-01-01

    Fault Management (FM) systems are ranked high in risk-based assessment of criticality within flight software, emphasizing the importance of establishing highly competent domain expertise to provide assurance for NASA projects, especially as spaceflight systems continue to increase in complexity. Insight into specific characteristics of FM architectures seen embedded within safety- and mission-critical software systems analyzed by the NASA Independent Verification Validation (IVV) Program has been enhanced with an FM Technical Reference (TR) suite. Benefits are aimed beyond the IVV community to those that seek ways to efficiently and effectively provide software assurance to reduce the FM risk posture of NASA and other space missions. The identification of particular FM architectures, visibility, and associated IVV techniques provides a TR suite that enables greater assurance that critical software systems will adequately protect against faults and respond to adverse conditions. The role FM has with regard to overall asset protection of flight software systems is being addressed with the development of an adverse condition (AC) database encompassing flight software vulnerabilities.Identification of potential off-nominal conditions and analysis to determine how a system responds to these conditions are important aspects of hazard analysis and fault management. Understanding what ACs the mission may face, and ensuring they are prevented or addressed is the responsibility of the assurance team, which necessarily should have insight into ACs beyond those defined by the project itself. Research efforts sponsored by NASAs Office of Safety and Mission Assurance defined terminology, categorized data fields, and designed a baseline repository that centralizes and compiles a comprehensive listing of ACs and correlated data relevant across many NASA missions. This prototype tool helps projects improve analysis by tracking ACs, and allowing queries based on project, mission

  3. Extreme hydrothermal conditions at an active plate-bounding fault

    NARCIS (Netherlands)

    Sutherland, Rupert; Townend, John; Toy, Virginia; Upton, Phaedra; Coussens, Jamie; Allen, Michael; Baratin, Laura May; Barth, Nicolas; Becroft, Leeza; Boese, Carolin; Boles, Austin; Boulton, Carolyn; Broderick, Neil G.R.; Janku-Capova, Lucie; Carpenter, Brett M.; Célérier, Bernard; Chamberlain, Calum; Cooper, Alan; Coutts, Ashley; Cox, Simon; Craw, Lisa; Doan, Mai Linh; Eccles, Jennifer; Faulkner, Dan; Grieve, Jason; Grochowski, Julia; Gulley, Anton; Hartog, Arthur; Howarth, Jamie; Jacobs, Katrina; Jeppson, Tamara; Kato, Naoki; Keys, Steven; Kirilova, Martina; Kometani, Yusuke; Langridge, Rob; Lin, Weiren; Little, Timothy; Lukacs, Adrienn; Mallyon, Deirdre; Mariani, Elisabetta; Massiot, Cécile; Mathewson, Loren; Melosh, Ben; Menzies, Catriona; Moore, Jo; Morales, Luiz; Morgan, Chance; Mori, Hiroshi; Niemeijer, Andre|info:eu-repo/dai/nl/370832132; Nishikawa, Osamu; Prior, David; Sauer, Katrina; Savage, Martha; Schleicher, Anja; Schmitt, Douglas R.; Shigematsu, Norio; Taylor-Offord, Sam; Teagle, Damon; Tobin, Harold; Valdez, Robert; Weaver, Konrad; Wiersberg, Thomas; Williams, Jack; Woodman, Nick; Zimmer, Martin

    2017-01-01

    Temperature and fluid pressure conditions control rock deformation and mineralization on geological faults, and hence the distribution of earthquakes. Typical intraplate continental crust has hydrostatic fluid pressure and a near-surface thermal gradient of 31 ± 15 degrees Celsius per kilometre. At

  4. The impact of excessive cutting on tree condition

    Directory of Open Access Journals (Sweden)

    Henryk Kociel

    2018-04-01

    Full Text Available The research was carried out to verify the impact of incorrect care practices on the value of trees. The research was carried out on a fragment of a lime-tree alley, located on a local road connecting Wólka Świątkowa and Krynka in the Lublin province. One side of the alley has been subjected to abnormal cuts, exceeding 50% of the volume of the crown, while the other remains intact. For this purpose, an analysis of the impact of the applied treatments on the condition of trees on the Rollof scale, analysis of life prognoses using the SULE method and the analysis of tree values and the assessment of tree loss as a result of cuts ensuing from the use of incorrect treatments were conducted. The analyses confirmed that the use of incorrect cuts contributed to the decline in the value of trees. The loss is so large that 1/3 of damaged trees have no chance for long and safe; moreover, these trees have lost 68% of their value.

  5. Urban tree species show the same hydraulic response to vapor pressure deficit across varying tree size and environmental conditions.

    Directory of Open Access Journals (Sweden)

    Lixin Chen

    Full Text Available The functional convergence of tree transpiration has rarely been tested for tree species growing under urban conditions even though it is of significance to elucidate the relationship between functional convergence and species differences of urban trees for establishing sustainable urban forests in the context of forest water relations.We measured sap flux of four urban tree species including Cedrus deodara, Zelkova schneideriana, Euonymus bungeanus and Metasequoia glyptostroboides in an urban park by using thermal dissipation probes (TDP. The concurrent microclimate conditions and soil moisture content were also measured. Our objectives were to examine 1 the influence of tree species and size on transpiration, and 2 the hydraulic control of urban trees under different environmental conditions over the transpiration in response to VPD as represented by canopy conductance. The results showed that the functional convergence between tree diameter at breast height (DBH and tree canopy transpiration amount (E(c was not reliable to predict stand transpiration and there were species differences within same DBH class. Species differed in transpiration patterns to seasonal weather progression and soil water stress as a result of varied sensitivity to water availability. Species differences were also found in their potential maximum transpiration rate and reaction to light. However, a same theoretical hydraulic relationship between G(c at VPD = 1 kPa (G(cref and the G(c sensitivity to VPD (-dG(c/dlnVPD across studied species as well as under contrasting soil water and R(s conditions in the urban area.We concluded that urban trees show the same hydraulic regulation over response to VPD across varying tree size and environmental conditions and thus tree transpiration could be predicted with appropriate assessment of G(cref.

  6. Urban tree species show the same hydraulic response to vapor pressure deficit across varying tree size and environmental conditions.

    Science.gov (United States)

    Chen, Lixin; Zhang, Zhiqiang; Ewers, Brent E

    2012-01-01

    The functional convergence of tree transpiration has rarely been tested for tree species growing under urban conditions even though it is of significance to elucidate the relationship between functional convergence and species differences of urban trees for establishing sustainable urban forests in the context of forest water relations. We measured sap flux of four urban tree species including Cedrus deodara, Zelkova schneideriana, Euonymus bungeanus and Metasequoia glyptostroboides in an urban park by using thermal dissipation probes (TDP). The concurrent microclimate conditions and soil moisture content were also measured. Our objectives were to examine 1) the influence of tree species and size on transpiration, and 2) the hydraulic control of urban trees under different environmental conditions over the transpiration in response to VPD as represented by canopy conductance. The results showed that the functional convergence between tree diameter at breast height (DBH) and tree canopy transpiration amount (E(c)) was not reliable to predict stand transpiration and there were species differences within same DBH class. Species differed in transpiration patterns to seasonal weather progression and soil water stress as a result of varied sensitivity to water availability. Species differences were also found in their potential maximum transpiration rate and reaction to light. However, a same theoretical hydraulic relationship between G(c) at VPD = 1 kPa (G(cref)) and the G(c) sensitivity to VPD (-dG(c)/dlnVPD) across studied species as well as under contrasting soil water and R(s) conditions in the urban area. We concluded that urban trees show the same hydraulic regulation over response to VPD across varying tree size and environmental conditions and thus tree transpiration could be predicted with appropriate assessment of G(cref).

  7. A fault tree analysis (FTA) of hydrogen explosion potentiality on reduction furnace ME-11 in nuclear power fuel element fabrication process

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2012-01-01

    Fault Tree Analysis (FTA) diagrams for the potentiality of hydrogen gas explosion in reduction furnace of ME-11 has been created after modification of its logic control. These FTA diagrams can be used as additional information in designing preventive maintenance program and operational steps of the furnace. The encountering of two conditions, i.e. explosion ignition and the potentially explosive of hydrogen gas, is the search focus of the FTA, and it may be done by breaking and tracing down to any possibility of initial causes for these two conditions to occur coincidently. Two locations of the potentially explosive area were identified: furnace chamber and combustion chamber of the exhaust gas. The possible explosion ignitions for the furnace are only from spark, fire and hot material because the operation of the furnace does not use high-pressure hydrogen. However, these explosion ignitions are part of the on going reduction process, therefore it is important that the hydrogen gas volume composition during the process always be supervised. (author)

  8. Analyses of robot systems using fault and event trees: case studies

    International Nuclear Information System (INIS)

    Khodabandehloo, Koorosh

    1996-01-01

    Safety in the use of robotics outside factories or processing plants has become a matter of great international concern. Domestic robots and those intended to assist nurses and surgeons in hospitals are examples of cases where safety and reliability are considered critical. The safe performance of robot systems depends on many factors, including the integrity of the robot's hardware and software, the way it communicates with sensory and other production equipment, the reliable function of the safety features present and the way the robot interacts with its environment. The use of systematic techniques such as Fault and Event Tree analysis to examine the safety and reliability of a given robotic system is presented. Considerable knowledge is needed before the application of such analysis techniques can be translated into safety specifications or indeed 'fail-safe' design features of robotic systems. The skill and understanding required for the formulation of such specifications is demonstrated here based on a number of case studies

  9. A decision-making framework for protecting process plants from flooding based on fault tree analysis

    International Nuclear Information System (INIS)

    Hauptmanns, Ulrich

    2010-01-01

    The protection of process plants from external events is mandatory in the Seveso Directive. Among these events figures the possibility of inundation of a plant, which may cause a hazard by disabling technical components and obviating operator interventions. A methodological framework for dealing with hazards from potential flooding events is presented. It combines an extension of the fault tree method with generic properties of flooding events in rivers and of dikes, which should be adapted to site-specific characteristics in a concrete case. Thus, a rational basis for deciding whether upgrading is required or not and which of the components should be upgraded is provided. Both the deterministic and the probabilistic approaches are compared. Preference is given to the probabilistic one. The conclusions drawn naturally depend on the scope and detail of the model calculations and the decision criterion adopted. The latter has to be supplied from outside the analysis, e.g. by the analyst himself, the plant operator or the competent authority. It turns out that decision-making is only viable if the boundary conditions for both the procedure of analysis and the decision criterion are clear.

  10. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    OpenAIRE

    Yoo, Cheol-Hee; Chung, Il-Yop; Yoo, Hyun-Jae; Hong, Sung-Soo

    2014-01-01

    Grid codes in many countries require low-voltage ride-through (LVRT) capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (P...

  11. An expert fault diagnosis system for vehicle air conditioning product development

    NARCIS (Netherlands)

    Tan, C.F.; Tee, B.T.; Khalil, S.N.; Chen, W.; Rauterberg, G.W.M.

    2015-01-01

    The paper describes the development of the vehicle air-conditioning fault diagnosis system in automotive industries with expert system shell. The main aim of the research is to diagnose the problem of new vehicle air-conditioning system development process and select the most suitable solution to

  12. Distributed Fault-Tolerant Control of Networked Uncertain Euler-Lagrange Systems Under Actuator Faults.

    Science.gov (United States)

    Chen, Gang; Song, Yongduan; Lewis, Frank L

    2016-05-03

    This paper investigates the distributed fault-tolerant control problem of networked Euler-Lagrange systems with actuator and communication link faults. An adaptive fault-tolerant cooperative control scheme is proposed to achieve the coordinated tracking control of networked uncertain Lagrange systems on a general directed communication topology, which contains a spanning tree with the root node being the active target system. The proposed algorithm is capable of compensating for the actuator bias fault, the partial loss of effectiveness actuation fault, the communication link fault, the model uncertainty, and the external disturbance simultaneously. The control scheme does not use any fault detection and isolation mechanism to detect, separate, and identify the actuator faults online, which largely reduces the online computation and expedites the responsiveness of the controller. To validate the effectiveness of the proposed method, a test-bed of multiple robot-arm cooperative control system is developed for real-time verification. Experiments on the networked robot-arms are conduced and the results confirm the benefits and the effectiveness of the proposed distributed fault-tolerant control algorithms.

  13. Methodology for selection of attributes and operating conditions for SVM-Based fault locator's

    Directory of Open Access Journals (Sweden)

    Debbie Johan Arredondo Arteaga

    2017-01-01

    Full Text Available Context: Energy distribution companies must employ strategies to meet their timely and high quality service, and fault-locating techniques represent and agile alternative for restoring the electric service in the power distribution due to the size of distribution services (generally large and the usual interruptions in the service. However, these techniques are not robust enough and present some limitations in both computational cost and the mathematical description of the models they use. Method: This paper performs an analysis based on a Support Vector Machine for the evaluation of the proper conditions to adjust and validate a fault locator for distribution systems; so that it is possible to determine the minimum number of operating conditions that allow to achieve a good performance with a low computational effort. Results: We tested the proposed methodology in a prototypical distribution circuit, located in a rural area of Colombia. This circuit has a voltage of 34.5 KV and is subdivided in 20 zones. Additionally, the characteristics of the circuit allowed us to obtain a database of 630.000 records of single-phase faults and different operating conditions. As a result, we could determine that the locator showed a performance above 98% with 200 suitable selected operating conditions. Conclusions: It is possible to improve the performance of fault locators based on Support Vector Machine. Specifically, these improvements are achieved by properly selecting optimal operating conditions and attributes, since they directly affect the performance in terms of efficiency and the computational cost.

  14. A fault diagnosis scheme for planetary gearboxes using adaptive multi-scale morphology filter and modified hierarchical permutation entropy

    Science.gov (United States)

    Li, Yongbo; Li, Guoyan; Yang, Yuantao; Liang, Xihui; Xu, Minqiang

    2018-05-01

    The fault diagnosis of planetary gearboxes is crucial to reduce the maintenance costs and economic losses. This paper proposes a novel fault diagnosis method based on adaptive multi-scale morphological filter (AMMF) and modified hierarchical permutation entropy (MHPE) to identify the different health conditions of planetary gearboxes. In this method, AMMF is firstly adopted to remove the fault-unrelated components and enhance the fault characteristics. Second, MHPE is utilized to extract the fault features from the denoised vibration signals. Third, Laplacian score (LS) approach is employed to refine the fault features. In the end, the obtained features are fed into the binary tree support vector machine (BT-SVM) to accomplish the fault pattern identification. The proposed method is numerically and experimentally demonstrated to be able to recognize the different fault categories of planetary gearboxes.

  15. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  16. SALP-3: A computer program for fault-tree analysis. Description and how-to-use. (Sensitivity analysis by list processing)

    International Nuclear Information System (INIS)

    Contini, S.; Astolfi, M.; Muysenberg, C.L. van den; Volta, G.

    1979-01-01

    The main characteristics and the how-to-use of the computer program SALP-3 for the analysis of coherent systems are described. The program is writen in PL/1 for the IBM/370-165. A syntactic analysis is made for the imput (fault-tree and data) and appropriate messages are supplied, should and error take place. The significant minimal cut sets (MCS) are searched by the use of algorithms based on the direct manipulation of the tree. The MCS, of whichever order, are supplied in output in order of importance with reference to a given probability threshold. The computer program SALP-3 represents only the intermediate results of a project whose objective is the implementation of a computer program for the analysis of both coherent and non-coherent structure functions, and, finally, for the automatic event tree analysis. The last part of the report illustrates the developments regarding the improvement in progress

  17. An application of the fault tree analysis for the power system reliability estimation

    International Nuclear Information System (INIS)

    Volkanovski, A.; Cepin, M.; Mavko, B.

    2007-01-01

    The power system is a complex system with its main function to produce, transfer and provide consumers with electrical energy. Combinations of failures of components in the system can result in a failure of power delivery to certain load points and in some cases in a full blackout of power system. The power system reliability directly affects safe and reliable operation of nuclear power plants because the loss of offsite power is a significant contributor to the core damage frequency in probabilistic safety assessments of nuclear power plants. The method, which is based on the integration of the fault tree analysis with the analysis of the power flows in the power system, was developed and implemented for power system reliability assessment. The main contributors to the power system reliability are identified, both quantitatively and qualitatively. (author)

  18. Topic Correlation Analysis for Bearing Fault Diagnosis Under Variable Operating Conditions

    Science.gov (United States)

    Chen, Chao; Shen, Fei; Yan, Ruqiang

    2017-05-01

    This paper presents a Topic Correlation Analysis (TCA) based approach for bearing fault diagnosis. In TCA, Joint Mixture Model (JMM), a model which adapts Probability Latent Semantic Analysis (PLSA), is constructed first. Then, JMM models the shared and domain-specific topics using “fault vocabulary” . After that, the correlations between two kinds of topics are computed and used to build a mapping matrix. Furthermore, a new shared space spanned by the shared and mapped domain-specific topics is set up where the distribution gap between different domains is reduced. Finally, a classifier is trained with mapped features which follow a different distribution and then the trained classifier is tested on target bearing data. Experimental results justify the superiority of the proposed approach over the stat-of-the-art baselines and it can diagnose bearing fault efficiently and effectively under variable operating conditions.

  19. IMPORTANCE, Minimal Cut Sets and System Availability from Fault Tree Analysis

    International Nuclear Information System (INIS)

    Lambert, H. W.

    1987-01-01

    1 - Description of problem or function: IMPORTANCE computes various measures of probabilistic importance of basic events and minimal cut sets to a fault tree or reliability network diagram. The minimal cut sets, the failure rates and the fault duration times (i.e., the repair times) of all basic events contained in the minimal cut sets are supplied as input data. The failure and repair distributions are assumed to be exponential. IMPORTANCE, a quantitative evaluation code, then determines the probability of the top event and computes the importance of minimal cut sets and basic events by a numerical ranking. Two measures are computed. The first describes system behavior at one point in time; the second describes sequences of failures that cause the system to fail in time. All measures are computed assuming statistical independence of basic events. In addition, system unavailability and expected number of system failures are computed by the code. 2 - Method of solution: Seven measures of basic event importance and two measures of cut set importance can be computed. Birnbaum's measure of importance (i.e., the partial derivative) and the probability of the top event are computed using the min cut upper bound. If there are no replicated events in the minimal cut sets, then the min cut upper bound is exact. If basic events are replicated in the minimal cut sets, then based on experience the min cut upper bound is accurate if the probability of the top event is less than 0.1. Simpson's rule is used in computing the time-integrated measures of importance. Newton's method for approximating the roots of an equation is employed in the options where the importance measures are computed as a function of the probability of the top event, and a shell sort puts the output in descending order of importance

  20. RELOSS, Reliability of Safety System by Fault Tree Analysis

    International Nuclear Information System (INIS)

    Allan, R.N.; Rondiris, I.L.; Adraktas, A.

    1981-01-01

    1 - Description of problem or function: Program RELOSS is used in the reliability/safety assessment of any complex system with predetermined operational logic in qualitative and (if required) quantitative terms. The program calculates the possible system outcomes following an abnormal operating condition and the probability of occurrence, if required. Furthermore, the program deduces the minimal cut or tie sets of the system outcomes and identifies the potential common mode failures. 4. Method of solution: The reliability analysis performed by the program is based on the event tree methodology. Using this methodology, the program develops the event tree of a system or a module of that system and relates each path of this tree to its qualitative and/or quantitative impact on specified system or module outcomes. If the system being analysed is subdivided into modules the program assesses each module in turn as described previously and then combines the module information to obtain results for the overall system. Having developed the event tree of a module or a system, the program identifies which paths lead or do not lead to various outcomes depending on whether the cut or the tie sets of the outcomes are required and deduces the corresponding sets. Furthermore the program identifies for a specific system outcome, the potential common mode failures and the cut or tie sets containing potential dependent failures of some components. 5. Restrictions on the complexity of the problem: The present dimensions of the program are as follows. They can however be easily modified: Maximum number of modules (equivalent components): 25; Maximum number of components in a module: 15; Maximum number of levels of parentheses in a logical statement: 10 Maximum number of system outcomes: 3; Maximum number of module outcomes: 2; Maximum number of points in time for which quantitative analysis is required: 5; Maximum order of any cut or tie set: 10; Maximum order of a cut or tie of any

  1. Risk assessment for enterprise resource planning (ERP) system implementations: a fault tree analysis approach

    Science.gov (United States)

    Zeng, Yajun; Skibniewski, Miroslaw J.

    2013-08-01

    Enterprise resource planning (ERP) system implementations are often characterised with large capital outlay, long implementation duration, and high risk of failure. In order to avoid ERP implementation failure and realise the benefits of the system, sound risk management is the key. This paper proposes a probabilistic risk assessment approach for ERP system implementation projects based on fault tree analysis, which models the relationship between ERP system components and specific risk factors. Unlike traditional risk management approaches that have been mostly focused on meeting project budget and schedule objectives, the proposed approach intends to address the risks that may cause ERP system usage failure. The approach can be used to identify the root causes of ERP system implementation usage failure and quantify the impact of critical component failures or critical risk events in the implementation process.

  2. Automated reasoning with dynamic event trees: a real-time, knowledge-based decision aide

    International Nuclear Information System (INIS)

    Touchton, R.A.; Gunter, A.D.; Subramanyan, N.

    1988-01-01

    The models and data contained in a probabilistic risk assessment (PRA) Event Sequence Analysis represent a wealth of information that can be used for dynamic calculation of event sequence likelihood. In this paper we report a new and unique computerization methodology which utilizes these data. This sub-system (referred to as PREDICTOR) has been developed and tested as part of a larger system. PREDICTOR performs a real-time (re)calculation of the estimated likelihood of core-melt as a function of plant status. This methodology uses object-oriented programming techniques from the artificial intelligence discipline that enable one to codify event tree and fault tree logic models and associated probabilities developed in a PRA study. Existence of off-normal conditions is reported to PREDICTOR, which then updates the relevant failure probabilities throughout the event tree and fault tree models by dynamically replacing the off-the-shelf (or prior) probabilities with new probabilities based on the current situation. The new event probabilities are immediately propagated through the models (using 'demons') and an updated core-melt probability is calculated. Along the way, the dominant non-success path of each event tree is determined and highlighted. (author)

  3. Double-layer rotor magnetic shield performance analysis in high temperature superconducting synchronous generators under short circuit fault conditions

    Science.gov (United States)

    Hekmati, Arsalan; Aliahmadi, Mehdi

    2016-12-01

    High temperature superconducting, HTS, synchronous machines benefit from a rotor magnetic shield in order to protect superconducting coils against asynchronous magnetic fields. This magnetic shield, however, suffers from exerted Lorentz forces generated in light of induced eddy currents during transient conditions, e.g. stator windings short-circuit fault. In addition, to the exerted electromagnetic forces, eddy current losses and the associated effects on the cryogenic system are the other consequences of shielding HTS coils. This study aims at investigating the Rotor Magnetic Shield, RMS, performance in HTS synchronous generators under stator winding short-circuit fault conditions. The induced eddy currents in different circumferential positions of the rotor magnetic shield along with associated Joule heating losses would be studied using 2-D time-stepping Finite Element Analysis, FEA. The investigation of Lorentz forces exerted on the magnetic shield during transient conditions has also been performed in this paper. The obtained results show that double line-to-ground fault is of the most importance among different types of short-circuit faults. It was revealed that when it comes to the design of the rotor magnetic shields, in addition to the eddy current distribution and the associated ohmic losses, two phase-to-ground fault should be taken into account since the produced electromagnetic forces in the time of fault conditions are more severe during double line-to-ground fault.

  4. Fungal diseases of tree stands under urbanized conditions of Moscow

    Directory of Open Access Journals (Sweden)

    Smirnova Oksana G.

    2013-01-01

    Full Text Available Phytosanitary and ecological estimation of tree-stands has been con­ducted at the Forest Experimental Station of Moscow Agricultural Academy and parks of Northeast of Moscow in 2007-2011. Fomes fomentarius was proved to be a very serious pathogen of trees under conditions of Moscow, Piptoporus betulinus, Phellinus igniarius, and Fomitopsis pinicola also occurred and caused damage to trees. This rather bad phytosanitary situation depends on alarming ecological situation in Moscow. At the Forest Experimental Station of Moscow Agricultural Academy a number and cover of lichens decreased. In general, all trees in Moscow are in dynamic equilibrium with the urbanized environment. In connection with this, the following classification of tree-stands was proposed for the urbanized environment: 1 - healthy trees, 2 - affected trees which can be managed, 3 - dry woods, 3a - very diseased. Many tree-stands in investigated regions of Moscow are found to belong to the groups 2 and 3c. All tree-stands must be carefully monitored and managed in order to provide a well-timed decision on the support system for preservation of trees as ‘lungs of city’ and avoid unpredictable tree falling which put people and traffic at risk.

  5. High-resolution gravity and seismic-refraction surveys of the Smoke Tree Wash area, Joshua Tree National Park, California

    Science.gov (United States)

    Langenheim, Victoria E.; Rymer, Michael J.; Catchings, Rufus D.; Goldman, Mark R.; Watt, Janet T.; Powell, Robert E.; Matti, Jonathan C.

    2016-03-02

    We describe high-resolution gravity and seismic refraction surveys acquired to determine the thickness of valley-fill deposits and to delineate geologic structures that might influence groundwater flow beneath the Smoke Tree Wash area in Joshua Tree National Park. These surveys identified a sedimentary basin that is fault-controlled. A profile across the Smoke Tree Wash fault zone reveals low gravity values and seismic velocities that coincide with a mapped strand of the Smoke Tree Wash fault. Modeling of the gravity data reveals a basin about 2–2.5 km long and 1 km wide that is roughly centered on this mapped strand, and bounded by inferred faults. According to the gravity model the deepest part of the basin is about 270 m, but this area coincides with low velocities that are not characteristic of typical basement complex rocks. Most likely, the density contrast assumed in the inversion is too high or the uncharacteristically low velocities represent highly fractured or weathered basement rocks, or both. A longer seismic profile extending onto basement outcrops would help differentiate which scenario is more accurate. The seismic velocities also determine the depth to water table along the profile to be about 40–60 m, consistent with water levels measured in water wells near the northern end of the profile.

  6. A New Fault Diagnosis Algorithm for PMSG Wind Turbine Power Converters under Variable Wind Speed Conditions

    Directory of Open Access Journals (Sweden)

    Yingning Qiu

    2016-07-01

    Full Text Available Although Permanent Magnet Synchronous Generator (PMSG wind turbines (WTs mitigate gearbox impacts, they requires high reliability of generators and converters. Statistical analysis shows that the failure rate of direct-drive PMSG wind turbines’ generators and inverters are high. Intelligent fault diagnosis algorithms to detect inverters faults is a premise for the condition monitoring system aimed at improving wind turbines’ reliability and availability. The influences of random wind speed and diversified control strategies lead to challenges for developing intelligent fault diagnosis algorithms for converters. This paper studies open-circuit fault features of wind turbine converters in variable wind speed situations through systematic simulation and experiment. A new fault diagnosis algorithm named Wind Speed Based Normalized Current Trajectory is proposed and used to accurately detect and locate faulted IGBT in the circuit arms. It is compared to direct current monitoring and current vector trajectory pattern approaches. The results show that the proposed method has advantages in the accuracy of fault diagnosis and has superior anti-noise capability in variable wind speed situations. The impact of the control strategy is also identified. Experimental results demonstrate its applicability on practical WT condition monitoring system which is used to improve wind turbine reliability and reduce their maintenance cost.

  7. Simultaneous Fault Detection and Sensor Selection for Condition Monitoring of Wind Turbines

    Directory of Open Access Journals (Sweden)

    Wenna Zhang

    2016-04-01

    Full Text Available Data collected from the supervisory control and data acquisition (SCADA system are used widely in wind farms to obtain operation and performance information about wind turbines. The paper presents a three-way model by means of parallel factor analysis (PARAFAC for wind turbine fault detection and sensor selection, and evaluates the method with SCADA data obtained from an operational farm. The main characteristic of this new approach is that it can be used to simultaneously explore measurement sample profiles and sensors profiles to avoid discarding potentially relevant information for feature extraction. With K-means clustering method, the measurement data indicating normal, fault and alarm conditions of the wind turbines can be identified, and the sensor array can be optimised for effective condition monitoring.

  8. [Spectrum Variance Analysis of Tree Leaves Under the Condition of Different Leaf water Content].

    Science.gov (United States)

    Wu, Jian; Chen, Tai-sheng; Pan, Li-xin

    2015-07-01

    Leaf water content is an important factor affecting tree spectral characteristics. So Exploring the leaf spectral characteristics change rule of the same tree under the condition of different leaf water content and the spectral differences of different tree leaves under the condition of the same leaf water content are not only the keys of hyperspectral vegetation remote sensing information identification but also the theoretical support of research on vegetation spectrum change as the differences in leaf water content. The spectrometer was used to observe six species of tree leaves, and the reflectivity and first order differential spectrum of different leaf water content were obtained. Then, the spectral characteristics of each tree species leaves under the condition of different leaf water content were analyzed, and the spectral differences of different tree species leaves under the condition of the same leaf water content were compared to explore possible bands of the leaf water content identification by hyperspectral remote sensing. Results show that the spectra of each tree leaf have changed a lot with the change of the leaf water content, but the change laws are different. Leaf spectral of different tree species has lager differences in some wavelength range under the condition of same leaf water content, and it provides some possibility for high precision identification of tree species.

  9. Analyzing dynamic fault trees derived from model-based system architectures

    International Nuclear Information System (INIS)

    Dehlinger, Josh; Dugan, Joanne Bechta

    2008-01-01

    Dependability-critical systems, such as digital instrumentation and control systems in nuclear power plants, necessitate engineering techniques and tools to provide assurances of their safety and reliability. Determining system reliability at the architectural design phase is important since it may guide design decisions and provide crucial information for trade-off analysis and estimating system cost. Despite this, reliability and system engineering remain separate disciplines and engineering processes by which the dependability analysis results may not represent the designed system. In this article we provide an overview and application of our approach to build architecture-based, dynamic system models for dependability-critical systems and then automatically generate Dynamic Fault Trees (DFT) for comprehensive, toolsupported reliability analysis. Specifically, we use the Architectural Analysis and Design Language (AADL) to model the structural, behavioral and failure aspects of the system in a composite architecture model. From the AADL model, we seek to derive the DFT(s) and use Galileo's automated reliability analyses to estimate system reliability. This approach alleviates the dependability engineering - systems engineering knowledge expertise gap, integrates the dependability and system engineering design and development processes and enables a more formal, automated and consistent DFT construction. We illustrate this work using an example based on a dynamic digital feed-water control system for a nuclear reactor

  10. Infrared Thermographic Diagnosis Mechanism for Fault Detection of Ball Bearing under Dynamic Loading Conditions

    International Nuclear Information System (INIS)

    Seo, Jin Ju; Yoon, Hanvit; Kim, Dong Yeon; Hong, Dong Pyo; Kim, Won Tae

    2011-01-01

    Fault detection for dynamic loading conditions of rotational machineries was considered from the contactless, non-destructive infrared thermographic method, rather than the traditional diagnosis method. In this paper, by applying a rotating deep-grooved ball bearing, passive thermographic experiment was performed as an alternative way proceeding the traditional fault monitoring. In addition, the thermographic experiments were compared with the vibration spectrum analysis to evaluate the efficiency of the proposed method. Based on the results, it was concluded the temperature characteristics of the ball bearing under dynamic loading conditions were analyzed thoroughly

  11. Failure mode effect analysis and fault tree analysis as a combined methodology in risk management

    Science.gov (United States)

    Wessiani, N. A.; Yoshio, F.

    2018-04-01

    There have been many studies reported the implementation of Failure Mode Effect Analysis (FMEA) and Fault Tree Analysis (FTA) as a method in risk management. However, most of the studies usually only choose one of these two methods in their risk management methodology. On the other side, combining these two methods will reduce the drawbacks of each methods when implemented separately. This paper aims to combine the methodology of FMEA and FTA in assessing risk. A case study in the metal company will illustrate how this methodology can be implemented. In the case study, this combined methodology will assess the internal risks that occur in the production process. Further, those internal risks should be mitigated based on their level of risks.

  12. An Overview of Risk Quantification Issues for Digitalized Nuclear Power Plants using a Static Fault Tree

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Gook; Kim, Man Cheol; Lee, Seung Jun; Lee, Ho Jung; Eom, Heung Seop; Chol, Jong Gyun; Jang, Seung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-08-15

    Risk caused by safety-critical instrumentation and control (I and C) systems considerably affects overall plant risk. As digitalization of safety-critical systems in nuclear power plants progresses, a risk model of a digitalized safety system is required and must be included in a plant safety model in order to assess this risk effect on the plant. Unique features of a digital system cause some challenges in risk modeling. This article aims at providing an overview of the issues related to the development of a static fault-tree-based risk model. We categorize the complicated issues of digital system probabilistic risk assessment (PRA) into four groups based on their characteristics: hardware module issues, software issues, system issues, and safety function issues. Quantification of the effect of these issues dominates the quality of a developed risk model. Recent research activities for addressing various issues, such as the modeling framework of a software-based system, the software failure probability and the fault coverage of a self monitoring mechanism, are discussed. Although these issues are interrelated and affect each other, the categorized and systematic approach suggested here will provide a proper insight for analyzing risk from a digital system

  13. Stress analyses of ITER toroidal field coils under fault conditions

    International Nuclear Information System (INIS)

    Jong, C.T.J.

    1990-02-01

    The International Thermonuclear Experimental Reactor (ITER) is intended as an experimental thermonuclear tokamak reactor for testing the basic physics, performance and technologies essential to future fusion reactors. The ITER design will be based on extensive new design work, supported by new physical and technological results, and on the great body of experience built up over several years from previous national and international reactor studies. Conversely, the ITER design process should provide the fusion community with valuable insights into what key areas need further development or clarification as we move forward towards practical fusion power. As part of the design process of the ITER toroidal field coils the mechanical behaviour of the magnetic system under fault conditions has to be analysed in more detail. This paper describes the work carried out to create a detailed finite element model of two toroidal field coils as well as some results of linear elastic analyses with fault conditions. The analyses have been performed with the finite element code ANSYS. (author). 5 refs.; 8 figs.; 2 tabs

  14. Fault Severity Evaluation and Improvement Design for Mechanical Systems Using the Fault Injection Technique and Gini Concordance Measure

    Directory of Open Access Journals (Sweden)

    Jianing Wu

    2014-01-01

    Full Text Available A new fault injection and Gini concordance based method has been developed for fault severity analysis for multibody mechanical systems concerning their dynamic properties. The fault tree analysis (FTA is employed to roughly identify the faults needed to be considered. According to constitution of the mechanical system, the dynamic properties can be achieved by solving the equations that include many types of faults which are injected by using the fault injection technique. Then, the Gini concordance is used to measure the correspondence between the performance with faults and under normal operation thereby providing useful hints of severity ranking in subsystems for reliability design. One numerical example and a series of experiments are provided to illustrate the application of the new method. The results indicate that the proposed method can accurately model the faults and receive the correct information of fault severity. Some strategies are also proposed for reliability improvement of the spacecraft solar array.

  15. Fault tolerant control for uncertain systems with parametric faults

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad

    2006-01-01

    A fault tolerant control (FTC) architecture based on active fault diagnosis (AFD) and the YJBK (Youla, Jarb, Bongiorno and Kucera)parameterization is applied in this paper. Based on the FTC architecture, fault tolerant control of uncertain systems with slowly varying parametric faults...... is investigated. Conditions are given for closed-loop stability in case of false alarms or missing fault detection/isolation....

  16. Locating hardware faults in a data communications network of a parallel computer

    Science.gov (United States)

    Archer, Charles J.; Megerian, Mark G.; Ratterman, Joseph D.; Smith, Brian E.

    2010-01-12

    Hardware faults location in a data communications network of a parallel computer. Such a parallel computer includes a plurality of compute nodes and a data communications network that couples the compute nodes for data communications and organizes the compute node as a tree. Locating hardware faults includes identifying a next compute node as a parent node and a root of a parent test tree, identifying for each child compute node of the parent node a child test tree having the child compute node as root, running a same test suite on the parent test tree and each child test tree, and identifying the parent compute node as having a defective link connected from the parent compute node to a child compute node if the test suite fails on the parent test tree and succeeds on all the child test trees.

  17. Analisa Penyebab Keterlambatan Proyek Pembangunan Sidoarjo Town Square Menggunakan Metode Fault Tree Analysis (FTA

    Directory of Open Access Journals (Sweden)

    Ridhati Amalia

    2012-09-01

    Full Text Available Setiap proyek konstruksi pada umumnya  mempunyai rencana pelaksanaan dan jadwal  pelaksanaan tertentu, kapan pelaksanaan proyek  tersebut harus dimulai, kapan proyek tersebut harus diselesaikan,  bagaimana proyek tersebut akan dikerjakan, serta  bagaimana penyediaan sumber dayanya. Diharapkan dalam pelaksanaanya tidak terjadi keterlambatan karena keterlambatan yang terjadi akan mengakibatkan meningkatnya biaya proyek. Namun, dalam pelaksanaan proyek pembangunan Sidoarjo Town Square mengalami keterlambatan. Metode yang direncanakan dalam pembahasan untuk mengetahui faktor yang mempengaruhi terjadinya keterlambatan yaitu Metode Fault Tree  Analysis (FTA dan Method Obtain Cut Set (MOCUS. Didapatkan bahwa item pekerjaan yang mengalami keterlambatan yaitu: pekerjaan struktur GWT STP, pekerjaan finishing fasade dan canopy, dan pekerjaan atap. Dari hasil analisa FTA dari ketiga top event, didapatkan bahwa keterlambatan terjadi dikarenakan  perubahan desain serta perijinan, dimana keduanya akibat faktor penyebab keterlambatan dari pihak owner.

  18. Risk-Significant Adverse Condition Awareness Strengthens Assurance of Fault Management Systems

    Science.gov (United States)

    Fitz, Rhonda

    2017-01-01

    As spaceflight systems increase in complexity, Fault Management (FM) systems are ranked high in risk-based assessment of software criticality, emphasizing the importance of establishing highly competent domain expertise to provide assurance. Adverse conditions (ACs) and specific vulnerabilities encountered by safety- and mission-critical software systems have been identified through efforts to reduce the risk posture of software-intensive NASA missions. Acknowledgement of potential off-nominal conditions and analysis to determine software system resiliency are important aspects of hazard analysis and FM. A key component of assuring FM is an assessment of how well software addresses susceptibility to failure through consideration of ACs. Focus on significant risk predicted through experienced analysis conducted at the NASA Independent Verification Validation (IVV) Program enables the scoping of effective assurance strategies with regard to overall asset protection of complex spaceflight as well as ground systems. Research efforts sponsored by NASA's Office of Safety and Mission Assurance defined terminology, categorized data fields, and designed a baseline repository that centralizes and compiles a comprehensive listing of ACs and correlated data relevant across many NASA missions. This prototype tool helps projects improve analysis by tracking ACs and allowing queries based on project, mission type, domaincomponent, causal fault, and other key characteristics. Vulnerability in off-nominal situations, architectural design weaknesses, and unexpected or undesirable system behaviors in reaction to faults are curtailed with the awareness of ACs and risk-significant scenarios modeled for analysts through this database. Integration within the Enterprise Architecture at NASA IVV enables interfacing with other tools and datasets, technical support, and accessibility across the Agency. This paper discusses the development of an improved workflow process utilizing this

  19. Automated Bearing Fault Diagnosis Using 2D Analysis of Vibration Acceleration Signals under Variable Speed Conditions

    Directory of Open Access Journals (Sweden)

    Sheraz Ali Khan

    2016-01-01

    Full Text Available Traditional fault diagnosis methods of bearings detect characteristic defect frequencies in the envelope power spectrum of the vibration signal. These defect frequencies depend upon the inherently nonstationary shaft speed. Time-frequency and subband signal analysis of vibration signals has been used to deal with random variations in speed, whereas design variations require retraining a new instance of the classifier for each operating speed. This paper presents an automated approach for fault diagnosis in bearings based upon the 2D analysis of vibration acceleration signals under variable speed conditions. Images created from the vibration signals exhibit unique textures for each fault, which show minimal variation with shaft speed. Microtexture analysis of these images is used to generate distinctive fault signatures for each fault type, which can be used to detect those faults at different speeds. A k-nearest neighbor classifier trained using fault signatures generated for one operating speed is used to detect faults at all the other operating speeds. The proposed approach is tested on the bearing fault dataset of Case Western Reserve University, and the results are compared with those of a spectrum imaging-based approach.

  20. Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors

    Directory of Open Access Journals (Sweden)

    Mišák Stanislav

    2017-06-01

    Full Text Available This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the above mentioned faults was developed. After having tested its operation, the system has already been implemented to protect mediumvoltage overhead lines built of covered conductors.

  1. Risk management of PPP project in the preparation stage based on Fault Tree Analysis

    Science.gov (United States)

    Xing, Yuanzhi; Guan, Qiuling

    2017-03-01

    The risk management of PPP(Public Private Partnership) project can improve the level of risk control between government departments and private investors, so as to make more beneficial decisions, reduce investment losses and achieve mutual benefit as well. Therefore, this paper takes the PPP project preparation stage venture as the research object to identify and confirm four types of risks. At the same time, fault tree analysis(FTA) is used to evaluate the risk factors that belong to different parts, and quantify the influencing degree of risk impact on the basis of risk identification. In addition, it determines the importance order of risk factors by calculating unit structure importance on PPP project preparation stage. The result shows that accuracy of government decision-making, rationality of private investors funds allocation and instability of market returns are the main factors to generate the shared risk on the project.

  2. Fault tree analysis of Project S-4404, Upgrade Canyon Exhaust System

    International Nuclear Information System (INIS)

    Browne, E.V.; Low, J.M.; Lux, C.R.

    1992-01-01

    Project S-4404, Upgrade Canyon Exhaust Systems, is a $177 million project with the purpose of upgrading the Exhaust Systems for both F and H Canyon Facilities. This upgrade will replace major portions of the F and H-Canyon exhaust systems, downstream of their respective sand filters with higher capacity and more reliable systems. Because of the high cost, DOE requested Program Control ampersand Integration (PC ampersand I) to examine specific deletions to the project. PC ampersand I requested Nuclear Processes Safety Research (NPSR) to perform an analysis to compare failure rates for the existing F ampersand H Canyon exhaust systems with the proposed exhaust system and specific proposed exhaust system alternatives. The objective of this work was to perform an analysis and compare failure rates for the existing F ampersand H Canyon exhaust systems with the proposed project exhaust system and proposed project alternatives. Based on fault tree analysis, two conclusions are made. First, D ampersand D activities can be eliminated from the project with no significant decrease to exhaust system safety. Deletion of D ampersand D activities would result in a cost savings of $29 million. Second, deletion of DOE Order 6430.1A requirements regarding DBAs would decrease exhaust system safety by a factor of 12

  3. Triggered surface slips in the Coachella Valley area associated with the 1992 Joshua Tree and Landers, California, Earthquakes

    Science.gov (United States)

    Rymer, M.J.

    2000-01-01

    The Coachella Valley area was strongly shaken by the 1992 Joshua Tree (23 April) and Landers (28 June) earthquakes, and both events caused triggered slip on active faults within the area. Triggered slip associated with the Joshua Tree earthquake was on a newly recognized fault, the East Wide Canyon fault, near the southwestern edge of the Little San Bernardino Mountains. Slip associated with the Landers earthquake formed along the San Andreas fault in the southeastern Coachella Valley. Surface fractures formed along the East Wide Canyon fault in association with the Joshua Tree earthquake. The fractures extended discontinuously over a 1.5-km stretch of the fault, near its southern end. Sense of slip was consistently right-oblique, west side down, similar to the long-term style of faulting. Measured offset values were small, with right-lateral and vertical components of slip ranging from 1 to 6 mm and 1 to 4 mm, respectively. This is the first documented historic slip on the East Wide Canyon fault, which was first mapped only months before the Joshua Tree earthquake. Surface slip associated with the Joshua Tree earthquake most likely developed as triggered slip given its 5 km distance from the Joshua Tree epicenter and aftershocks. As revealed in a trench investigation, slip formed in an area with only a thin (Salton Trough. A paleoseismic trench study in an area of 1992 surface slip revealed evidence of two and possibly three surface faulting events on the East Wide Canyon fault during the late Quaternary, probably latest Pleistocene (first event) and mid- to late Holocene (second two events). About two months after the Joshua Tree earthquake, the Landers earthquake then triggered slip on many faults, including the San Andreas fault in the southeastern Coachella Valley. Surface fractures associated with this event formed discontinuous breaks over a 54-km-long stretch of the fault, from the Indio Hills southeastward to Durmid Hill. Sense of slip was right

  4. Multi-state system in a fault tree analysis of a nuclear based thermochemical hydrogen plant

    International Nuclear Information System (INIS)

    Zhang, Y.

    2008-01-01

    Nuclear-based hydrogen generation is a promising way to supply hydrogen for this large market in the future. This thesis focuses on one of the most promising methods, a thermochemical Cu-Cl cycle, which is currently under development by UOIT, Atomic Energy of Canada Limited (AECL) and the Argonne National Laboratory (ANL). The safety issues of the Cu-Cl cycle are addressed in this thesis. An investigation of major accident scenarios shows that potential tragedies can be avoided with effective risk analysis and safety management programs. As a powerful and systematic tool, fault tree analysis (FTA) is adapted to the particular needs of the Cu-Cl system. This thesis develops a new method that combines FTA with a reliability analysis tool, multi-state system (MSS), to improve the accuracy of FTA and also improve system reliability. (author)

  5. A simple component-connection method for building binary decision diagrams encoding a fault tree

    International Nuclear Information System (INIS)

    Way, Y.-S.; Hsia, D.-Y.

    2000-01-01

    A simple new method for building binary decision diagrams (BDDs) encoding a fault tree (FT) is provided in this study. We first decompose the FT into FT-components. Each of them is a single descendant (SD) gate-sequence. Following the node-connection rule, the BDD-component encoding an SD FT-component can each be found to be an SD node-sequence. By successively connecting the BDD-components one by one, the BDD for the entire FT is thus obtained. During the node-connection and component-connection, reduction rules might need to be applied. An example FT is used throughout the article to explain the procedure step by step. Our method proposed is a hybrid one for FT analysis. Some algorithms or techniques used in the conventional FT analysis or the newer BDD approach may be applied to our case; our ideas mentioned in the article might be referred by the two methods

  6. Control of power converters in distributed generation applications under grid fault conditions

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Luna, Alvaro; Munoz-Aguilar, Raul

    2011-01-01

    The operation of distributed power generation systems under grid fault conditions is a key issue for the massive integration of renewable energy systems. Several studies have been conducted to improve the response of such distributed generation systems under voltage dips. In spite of being less s...

  7. SCENARIO OF AN ACCIDENT OF SOIL DAMS IN CASE OF WATER SPILL OVER A DAM CREST BY USING FAULT TREE ANALYSIS

    OpenAIRE

    Kuznetsov Dmitriy Viktorovich

    2016-01-01

    The scenario of a hydrodynamic accident of water flow over a crest of a soil dam is considered by the method of fault tree analysis, for which the basic reasons and controlled diagnostic indicators of an accident have been defined. Logical operators “AND”/”OR” were used for creation of a sequence of logically connected events, leading to an undesired event in the scenario of accident. The scenario of the accident was plotted in case of three basic reasons - an excessive settling of a dam cres...

  8. SETS, Boolean Manipulation for Network Analysis and Fault Tree Analysis

    International Nuclear Information System (INIS)

    Worrell, R.B.

    1985-01-01

    Description of problem or function - SETS is used for symbolic manipulation of set (or Boolean) equations, particularly the reduction of set equations by the application of set identities. It is a flexible and efficient tool for performing probabilistic risk analysis (PRA), vital area analysis, and common cause analysis. The equation manipulation capabilities of SETS can also be used to analyze non-coherent fault trees and determine prime implicants of Boolean functions, to verify circuit design implementation, to determine minimum cost fire protection requirements for nuclear reactor plants, to obtain solutions to combinatorial optimization problems with Boolean constraints, and to determine the susceptibility of a facility to unauthorized access through nullification of sensors in its protection system. 4. Method of solution - The SETS program is used to read, interpret, and execute the statements of a SETS user program which is an algorithm that specifies the particular manipulations to be performed and the order in which they are to occur. 5. Restrictions on the complexity of the problem - Any properly formed set equation involving the set operations of union, intersection, and complement is acceptable for processing by the SETS program. Restrictions on the size of a set equation that can be processed are not absolute but rather are related to the number of terms in the disjunctive normal form of the equation, the number of literals in the equation, etc. Nevertheless, set equations involving thousands and even hundreds of thousands of terms can be processed successfully

  9. Research and Application of FTA and Petri Nets in Fault Diagnosis in the Pantograph-Type Current Collector on CRH EMU Trains

    Directory of Open Access Journals (Sweden)

    Long-long Song

    2015-01-01

    Full Text Available A fault tree is established based on structural analysis, working principle analysis, and failure mode and effects analysis (FMEA of the pantograph-type current collector on the Chinese Rail High-Speed Electric Multiple Unit (CRH EMU train. To avoid the deficiencies of fault tree analysis (FTA, Petri nets modelling is used to address the problem of data explosion and carry out dynamic diagnosis. Relational matrix analysis is used to solve the minimal cut set equation of the fault tree. Based on the established state equation of the Petri nets, initial tokens and enable-transfer algorithms are used to express the fault transfer process mathematically and improve the efficiency of fault diagnosis inferences. Finally, using a practical fault diagnosis example for the pantographs on CRH EMU trains, the proposed method is proved to be reasonable and effective.

  10. Gear fault diagnosis under variable conditions with intrinsic time-scale decomposition-singular value decomposition and support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Zhanqiang; Qu, Jianfeng; Chai, Yi; Tang, Qiu; Zhou, Yuming [Chongqing University, Chongqing (China)

    2017-02-15

    The gear vibration signal is nonlinear and non-stationary, gear fault diagnosis under variable conditions has always been unsatisfactory. To solve this problem, an intelligent fault diagnosis method based on Intrinsic time-scale decomposition (ITD)-Singular value decomposition (SVD) and Support vector machine (SVM) is proposed in this paper. The ITD method is adopted to decompose the vibration signal of gearbox into several Proper rotation components (PRCs). Subsequently, the singular value decomposition is proposed to obtain the singular value vectors of the proper rotation components and improve the robustness of feature extraction under variable conditions. Finally, the Support vector machine is applied to classify the fault type of gear. According to the experimental results, the performance of ITD-SVD exceeds those of the time-frequency analysis methods with EMD and WPT combined with SVD for feature extraction, and the classifier of SVM outperforms those for K-nearest neighbors (K-NN) and Back propagation (BP). Moreover, the proposed approach can accurately diagnose and identify different fault types of gear under variable conditions.

  11. Fault diagnosis of sensor networked structures with multiple faults using a virtual beam based approach

    Science.gov (United States)

    Wang, H.; Jing, X. J.

    2017-07-01

    This paper presents a virtual beam based approach suitable for conducting diagnosis of multiple faults in complex structures with limited prior knowledge of the faults involved. The "virtual beam", a recently-proposed concept for fault detection in complex structures, is applied, which consists of a chain of sensors representing a vibration energy transmission path embedded in the complex structure. Statistical tests and adaptive threshold are particularly adopted for fault detection due to limited prior knowledge of normal operational conditions and fault conditions. To isolate the multiple faults within a specific structure or substructure of a more complex one, a 'biased running' strategy is developed and embedded within the bacterial-based optimization method to construct effective virtual beams and thus to improve the accuracy of localization. The proposed method is easy and efficient to implement for multiple fault localization with limited prior knowledge of normal conditions and faults. With extensive experimental results, it is validated that the proposed method can localize both single fault and multiple faults more effectively than the classical trust index subtract on negative add on positive (TI-SNAP) method.

  12. Condition trees as a mechanism for communicating the meaning of uncertainties

    Science.gov (United States)

    Beven, Keith

    2015-04-01

    Uncertainty communication for environmental problems is fraught with difficulty for good epistemic reasons. The fact that most sources of uncertainty are subject to, and often dominated by, epistemic uncertainties means that the unthinking use of probability theory might actually be misleading and lead to false inference (even in some cases where the assumptions of a probabilistic error model might seem to be reasonably valid). This therefore creates problems in communicating the meaning of probabilistic uncertainties of model predictions to potential users (there are many examples in hydrology, hydraulics, climate change and other domains). It is suggested that one way of being more explicit about the meaning of uncertainties is to associate each type of application with a condition tree of assumptions that need to be made in producing an estimate of uncertainty. The condition tree then provides a basis for discussion and communication of assumptions about uncertainties with users. Agreement of assumptions (albeit generally at some institutional level) will provide some buy-in on the part of users, and a basis for commissioning of future studies. Even in some relatively well-defined problems, such as mapping flood risk, such a condition tree can be rather extensive, but by making each step in the tree explicit then an audit trail is established for future reference. This can act to provide focus in the exercise of agreeing more realistic assumptions.

  13. Simulation of tree shade impacts on residential energy use for space conditioning in Sacramento

    Science.gov (United States)

    Simpson, J. R.; McPherson, E. G.

    Tree shade reduces summer air conditioning demand and increases winter heating load by intercepting solar energy that would otherwise heat the shaded structure. We evaluate the magnitude of these effects here for 254 residential properties participating in a utility sponsored tree planting program in Sacramento, California. Tree and building characteristics and typical weather data are used to model hourly shading and energy used for space conditioning for each building for a period of one year. There were an average of 3.1 program trees per property which reduced annual and peak (8 h average from 1 to 9 p.m. Pacific Daylight Time) cooling energy use 153 kWh (7.1%) and 0.08 kW (2.3%) per tree, respectively. Annual heating load increased 0.85 GJ (0.80 MBtu, 1.9%) per tree. Changes in cooling load were smaller, but percentage changes larger, for newer buildings. Averaged over all homes, annual cooling savings of 15.25 per tree were reduced by a heating penalty of 5.25 per tree, for net savings of 10.00 per tree from shade. We estimate an annual cooling penalty of 2.80 per tree and heating savings of 6.80 per tree from reduced wind speed, for a net savings of 4.00 per tree, and total annual savings of 14.00 per tree (43.00 per property). Results are found to be consistent with previous simulations and the limited measurements available.

  14. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  15. Fault Detection and Diagnosis for Gas Turbines Based on a Kernelized Information Entropy Model

    Directory of Open Access Journals (Sweden)

    Weiying Wang

    2014-01-01

    Full Text Available Gas turbines are considered as one kind of the most important devices in power engineering and have been widely used in power generation, airplanes, and naval ships and also in oil drilling platforms. However, they are monitored without man on duty in the most cases. It is highly desirable to develop techniques and systems to remotely monitor their conditions and analyze their faults. In this work, we introduce a remote system for online condition monitoring and fault diagnosis of gas turbine on offshore oil well drilling platforms based on a kernelized information entropy model. Shannon information entropy is generalized for measuring the uniformity of exhaust temperatures, which reflect the overall states of the gas paths of gas turbine. In addition, we also extend the entropy to compute the information quantity of features in kernel spaces, which help to select the informative features for a certain recognition task. Finally, we introduce the information entropy based decision tree algorithm to extract rules from fault samples. The experiments on some real-world data show the effectiveness of the proposed algorithms.

  16. Fault detection and diagnosis for gas turbines based on a kernelized information entropy model.

    Science.gov (United States)

    Wang, Weiying; Xu, Zhiqiang; Tang, Rui; Li, Shuying; Wu, Wei

    2014-01-01

    Gas turbines are considered as one kind of the most important devices in power engineering and have been widely used in power generation, airplanes, and naval ships and also in oil drilling platforms. However, they are monitored without man on duty in the most cases. It is highly desirable to develop techniques and systems to remotely monitor their conditions and analyze their faults. In this work, we introduce a remote system for online condition monitoring and fault diagnosis of gas turbine on offshore oil well drilling platforms based on a kernelized information entropy model. Shannon information entropy is generalized for measuring the uniformity of exhaust temperatures, which reflect the overall states of the gas paths of gas turbine. In addition, we also extend the entropy to compute the information quantity of features in kernel spaces, which help to select the informative features for a certain recognition task. Finally, we introduce the information entropy based decision tree algorithm to extract rules from fault samples. The experiments on some real-world data show the effectiveness of the proposed algorithms.

  17. Machine Learning of Fault Friction

    Science.gov (United States)

    Johnson, P. A.; Rouet-Leduc, B.; Hulbert, C.; Marone, C.; Guyer, R. A.

    2017-12-01

    We are applying machine learning (ML) techniques to continuous acoustic emission (AE) data from laboratory earthquake experiments. Our goal is to apply explicit ML methods to this acoustic datathe AE in order to infer frictional properties of a laboratory fault. The experiment is a double direct shear apparatus comprised of fault blocks surrounding fault gouge comprised of glass beads or quartz powder. Fault characteristics are recorded, including shear stress, applied load (bulk friction = shear stress/normal load) and shear velocity. The raw acoustic signal is continuously recorded. We rely on explicit decision tree approaches (Random Forest and Gradient Boosted Trees) that allow us to identify important features linked to the fault friction. A training procedure that employs both the AE and the recorded shear stress from the experiment is first conducted. Then, testing takes place on data the algorithm has never seen before, using only the continuous AE signal. We find that these methods provide rich information regarding frictional processes during slip (Rouet-Leduc et al., 2017a; Hulbert et al., 2017). In addition, similar machine learning approaches predict failure times, as well as slip magnitudes in some cases. We find that these methods work for both stick slip and slow slip experiments, for periodic slip and for aperiodic slip. We also derive a fundamental relationship between the AE and the friction describing the frictional behavior of any earthquake slip cycle in a given experiment (Rouet-Leduc et al., 2017b). Our goal is to ultimately scale these approaches to Earth geophysical data to probe fault friction. References Rouet-Leduc, B., C. Hulbert, N. Lubbers, K. Barros, C. Humphreys and P. A. Johnson, Machine learning predicts laboratory earthquakes, in review (2017). https://arxiv.org/abs/1702.05774Rouet-LeDuc, B. et al., Friction Laws Derived From the Acoustic Emissions of a Laboratory Fault by Machine Learning (2017), AGU Fall Meeting Session S025

  18. Model-Based Sensor Placement for Component Condition Monitoring and Fault Diagnosis in Fossil Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mobed, Parham [Texas Tech Univ., Lubbock, TX (United States); Pednekar, Pratik [West Virginia Univ., Morgantown, WV (United States); Bhattacharyya, Debangsu [West Virginia Univ., Morgantown, WV (United States); Turton, Richard [West Virginia Univ., Morgantown, WV (United States); Rengaswamy, Raghunathan [Texas Tech Univ., Lubbock, TX (United States)

    2016-01-29

    Design and operation of energy producing, near “zero-emission” coal plants has become a national imperative. This report on model-based sensor placement describes a transformative two-tier approach to identify the optimum placement, number, and type of sensors for condition monitoring and fault diagnosis in fossil energy system operations. The algorithms are tested on a high fidelity model of the integrated gasification combined cycle (IGCC) plant. For a condition monitoring network, whether equipment should be considered at a unit level or a systems level depends upon the criticality of the process equipment, its likeliness to fail, and the level of resolution desired for any specific failure. Because of the presence of a high fidelity model at the unit level, a sensor network can be designed to monitor the spatial profile of the states and estimate fault severity levels. In an IGCC plant, besides the gasifier, the sour water gas shift (WGS) reactor plays an important role. In view of this, condition monitoring of the sour WGS reactor is considered at the unit level, while a detailed plant-wide model of gasification island, including sour WGS reactor and the Selexol process, is considered for fault diagnosis at the system-level. Finally, the developed algorithms unify the two levels and identifies an optimal sensor network that maximizes the effectiveness of the overall system-level fault diagnosis and component-level condition monitoring. This work could have a major impact on the design and operation of future fossil energy plants, particularly at the grassroots level where the sensor network is yet to be identified. In addition, the same algorithms developed in this report can be further enhanced to be used in retrofits, where the objectives could be upgrade (addition of more sensors) and relocation of existing sensors.

  19. Quantitative analysis of dynamic fault trees using improved Sequential Binary Decision Diagrams

    International Nuclear Information System (INIS)

    Ge, Daochuan; Lin, Meng; Yang, Yanhua; Zhang, Ruoxing; Chou, Qiang

    2015-01-01

    Dynamic fault trees (DFTs) are powerful in modeling systems with sequence- and function dependent failure behaviors. The key point lies in how to quantify complex DFTs analytically and efficiently. Unfortunately, the existing methods for analyzing DFTs all have their own disadvantages. They either suffer from the problem of combinatorial explosion or need a long computation time to obtain an accurate solution. Sequential Binary Decision Diagrams (SBDDs) are regarded as novel and efficient approaches to deal with DFTs, but their two apparent shortcomings remain to be handled: That is, SBDDs probably generate invalid nodes when given an unpleasant variable index and the scale of the resultant cut sequences greatly relies on the chosen variable index. An improved SBDD method is proposed in this paper to deal with the two mentioned problems. It uses an improved ite (If-Then-Else) algorithm to avoid generating invalid nodes when building SBDDs, and a heuristic variable index to keep the scale of resultant cut sequences as small as possible. To confirm the applicability and merits of the proposed method, several benchmark examples are demonstrated, and the results indicate this approach is efficient as well as reasonable. - Highlights: • New ITE method. • Linear complexity-based finding algorithm. • Heuristic variable index

  20. Generation Risk Assessment Using Fault Trees and Turbine Cycle Simulation: Case Studies

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Park, Jin Kyun

    2009-01-01

    Since 2007, Korea Atomic Energy Research Institute and Kyung Hee University have collaborated on the development of the framework to quantify human errors broken out during the test and maintenance (T and M) in secondary systems of nuclear power plants (NPPs). The project entitled 'Development of Causality Analyzer for Maintenance/Test Tasks in Nuclear Power Plants' for OPR1000 on the basis of the proposed framework is still on-going, and will come to fruition by 2010. The overall concept of GRA-HRE (Generation Risk Assessment for Human Related Events) which is the designation of the framework, and the quantification methods for evaluating risk and electric loss have introduced in other references. The originality emerged while implementing GRA-HRE could be evaluated in view of (1) recognizing the relative importance of human errors comparing with other types of mechanical and/or electrical failures, (2) providing the top-down path of the propagation of human errors by designating top events in the fault tree model as trip signals, and (3) analyzing electric loss using turbine cycle simulation. Recently, we were successfully to illustrate the applicability of GRA-HRE by simulating several abnormalities. Since the detailed methodologies were released enough to follow up, this paper is going to only exemplify the case studies

  1. Fault tolerant control with torque limitation based on fault mode for ten-phase permanent magnet synchronous motor

    Directory of Open Access Journals (Sweden)

    Guo Hong

    2015-10-01

    Full Text Available This paper proposes a novel fault tolerant control with torque limitation based on the fault mode for the ten-phase permanent magnet synchronous motor (PMSM under various open-circuit and short-circuit fault conditions, which includes the optimal torque control and the torque limitation control based on the fault mode. The optimal torque control is adopted to guarantee the ripple-free electromagnetic torque operation for the ten-phase motor system under the post-fault condition. Furthermore, we systematically analyze the load capacity of the ten-phase motor system under different fault modes. And a torque limitation control approach based on the fault mode is proposed, which was not available earlier. This approach is able to ensure the safety operation of the faulted motor system in long operating time without causing the overheat fault. The simulation result confirms that the proposed fault tolerant control for the ten-phase motor system is able to guarantee the ripple-free electromagnetic torque and the safety operation in long operating time under the normal and fault conditions.

  2. Current Control Method for Distributed Generation Power Generation Plants under Grid Fault Conditions

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Luna, Alvaro; Hermoso, Juan Ramon

    2011-01-01

    The operation of distributed power generation systems under grid fault conditions is a key issue for the massive integration of renewable energy systems. Several studies have been conducted to improve the response of such distributed generation systems under voltage dips. In spite of being less s...

  3. Striation and slickenline development on quartz fault surfaces at crustal conditions : Origin and effect on friction

    NARCIS (Netherlands)

    Toy, Virginia G.; Niemeijer, André; Renard, Francois; Morales, Luiz; Wirth, Richard

    Fragments of optically flat silica discs embedded in synthetic gouge were deformed to examine the relationship between the development of striations and slickenlines, and deformation mechanisms, conditions, and fault rheology. Experiments were performed under hydrothermal conditions in a rotary

  4. Application of reliability-centered maintenance to boiling water reactor emergency core cooling systems fault-tree analysis

    International Nuclear Information System (INIS)

    Choi, Y.A.; Feltus, M.A.

    1995-01-01

    Reliability-centered maintenance (RCM) methods are applied to boiling water reactor plant-specific emergency core cooling system probabilistic risk assessment (PRA) fault trees. The RCM is a technique that is system function-based, for improving a preventive maintenance (PM) program, which is applied on a component basis. Many PM programs are based on time-directed maintenance tasks, while RCM methods focus on component condition-directed maintenance tasks. Stroke time test data for motor-operated valves (MOVs) are used to address three aspects concerning RCM: (a) to determine if MOV stroke time testing was useful as a condition-directed PM task; (b) to determine and compare the plant-specific MOV failure data from a broad RCM philosophy time period compared with a PM period and, also, compared with generic industry MOV failure data; and (c) to determine the effects and impact of the plant-specific MOV failure data on core damage frequency (CDF) and system unavailabilities for these emergency systems. The MOV stroke time test data from four emergency core cooling systems [i.e., high-pressure coolant injection (HPCI), reactor core isolation cooling (RCIC), low-pressure core spray (LPCS), and residual heat removal/low-pressure coolant injection (RHR/LPCI)] were gathered from Philadelphia Electric Company's Peach Bottom Atomic Power Station Units 2 and 3 between 1980 and 1992. The analyses showed that MOV stroke time testing was not a predictor for eminent failure and should be considered as a go/no-go test. The failure data from the broad RCM philosophy showed an improvement compared with the PM-period failure rates in the emergency core cooling system MOVs. Also, the plant-specific MOV failure rates for both maintenance philosophies were shown to be lower than the generic industry estimates

  5. Spectral Kurtosis Entropy and Weighted SaE-ELM for Bogie Fault Diagnosis under Variable Conditions

    Directory of Open Access Journals (Sweden)

    Zhipeng Wang

    2018-05-01

    Full Text Available Bogies are crucial for the safe operation of rail transit systems and usually work under uncertain and variable operating conditions. However, the diagnosis of bogie faults under variable conditions has barely been discussed until now. Thus, it is valuable to develop effective methods to deal with variable conditions. Besides, considering that the normal data for training are much more than the faulty data in practice, there is another problem in that only a small amount of data is available that includes faults. Concerning these issues, this paper proposes two new algorithms: (1 A novel feature parameter named spectral kurtosis entropy (SKE is proposed based on the protrugram. The SKE not only avoids the manual post-processing of the protrugram but also has strong robustness to the operating conditions and parameter configurations, which have been validated by a simulation experiment in this paper. In this paper, the SKE, in conjunction with variational mode decomposition (VMD, is employed for feature extraction under variable conditions. (2 A new learning algorithm named weighted self-adaptive evolutionary extreme learning machine (WSaE-ELM is proposed. WSaE-ELM gives each sample an extra sample weight to rebalance the training data and optimizes these weights along with the parameters of hidden neurons by means of the self-adaptive differential evolution algorithm. Finally, the hybrid method based on VMD, SKE, and WSaE-ELM is verified by using the vibration signals gathered from real bogies with speed variations. It is demonstrated that the proposed method of bogie fault diagnosis outperforms the conventional methods by up to 4.42% and 6.22%, respectively, in percentages of accuracy under variable conditions.

  6. A prototype expert system to support the development of a fault-tree analysis software for nuclear reactor safety

    International Nuclear Information System (INIS)

    Mesko, L.

    1990-01-01

    The project called EMERIS is designed to provide a material testing nuclear reactor and experimental loops with a software for the 'acquisition, evaluation and archivation of measured data during the operation of the experimental facility'. The project which gives job a team has a duration of two years and involves three Vax compatible TPA-type computers and many smaller computers for data digitalization and graphical workstations. The detailed description of the project is not the task of the paper. One of its modules, however, plays an important role in the considerations. Namely the module for distrubance analysis (DA) which is planned to perform a rule based on-line evaluation of numerous predefined fault trees in an expert system like environment

  7. Diagnosis of three types of constant faults in read-once contact networks over finite bases

    KAUST Repository

    Busbait, Monther I.

    2016-03-24

    We study the depth of decision trees for diagnosis of three types of constant faults in read-once contact networks over finite bases containing only indecomposable networks. For each basis and each type of faults, we obtain a linear upper bound on the minimum depth of decision trees depending on the number of edges in networks. For bases containing networks with at most 10 edges, we find sharp coefficients for linear bounds.

  8. Bearing faults identification and resonant band demodulation based on wavelet de-noising methods and envelope analysis

    Science.gov (United States)

    Abdelrhman, Ahmed M.; Sei Kien, Yong; Salman Leong, M.; Meng Hee, Lim; Al-Obaidi, Salah M. Ali

    2017-07-01

    The vibration signals produced by rotating machinery contain useful information for condition monitoring and fault diagnosis. Fault severities assessment is a challenging task. Wavelet Transform (WT) as a multivariate analysis tool is able to compromise between the time and frequency information in the signals and served as a de-noising method. The CWT scaling function gives different resolutions to the discretely signals such as very fine resolution at lower scale but coarser resolution at a higher scale. However, the computational cost increased as it needs to produce different signal resolutions. DWT has better low computation cost as the dilation function allowed the signals to be decomposed through a tree of low and high pass filters and no further analysing the high-frequency components. In this paper, a method for bearing faults identification is presented by combing Continuous Wavelet Transform (CWT) and Discrete Wavelet Transform (DWT) with envelope analysis for bearing fault diagnosis. The experimental data was sampled by Case Western Reserve University. The analysis result showed that the proposed method is effective in bearing faults detection, identify the exact fault’s location and severity assessment especially for the inner race and outer race faults.

  9. Scissoring Fault Rupture Properties along the Median Tectonic Line Fault Zone, Southwest Japan

    Science.gov (United States)

    Ikeda, M.; Nishizaka, N.; Onishi, K.; Sakamoto, J.; Takahashi, K.

    2017-12-01

    The Median Tectonic Line fault zone (hereinafter MTLFZ) is the longest and most active fault zone in Japan. The MTLFZ is a 400-km-long trench parallel right-lateral strike-slip fault accommodating lateral slip components of the Philippine Sea plate oblique subduction beneath the Eurasian plate [Fitch, 1972; Yeats, 1996]. Complex fault geometry evolves along the MTLFZ. The geomorphic and geological characteristics show a remarkable change through the MTLFZ. Extensional step-overs and pull-apart basins and a pop-up structure develop in western and eastern parts of the MTLFZ, respectively. It is like a "scissoring fault properties". We can point out two main factors to form scissoring fault properties along the MTLFZ. One is a regional stress condition, and another is a preexisting fault. The direction of σ1 anticlockwise rotate from N170°E [Famin et al., 2014] in the eastern Shikoku to Kinki areas and N100°E [Research Group for Crustral Stress in Western Japan, 1980] in central Shikoku to N85°E [Onishi et al., 2016] in western Shikoku. According to the rotation of principal stress directions, the western and eastern parts of the MTLFZ are to be a transtension and compression regime, respectively. The MTLFZ formed as a terrain boundary at Cretaceous, and has evolved with a long active history. The fault style has changed variously, such as left-lateral, thrust, normal and right-lateral. Under the structural condition of a preexisting fault being, the rupture does not completely conform to Anderson's theory for a newly formed fault, as the theory would require either purely dip-slip motion on the 45° dipping fault or strike-slip motion on a vertical fault. The fault rupture of the 2013 Barochistan earthquake in Pakistan is a rare example of large strike-slip reactivation on a relatively low angle dipping fault (thrust fault), though many strike-slip faults have vertical plane generally [Avouac et al., 2014]. In this presentation, we, firstly, show deep subsurface

  10. The application of a coupled artificial neural network and fault tree analysis model to predict coal and gas outbursts

    Energy Technology Data Exchange (ETDEWEB)

    Ruilin, Zhang [School of Safety Science and Engineering, Henan Polytechnic University, Jiaozuo, Henan Province, 454003, PR (China); Lowndes, Ian S. [Process and Environmental Research Division, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD (United Kingdom)

    2010-11-01

    This paper proposes the use of a coupled fault tree analysis (FTA) and artificial neural network (ANN) model to improve the prediction of the potential risk of coal and gas outburst events during the underground mining of thick and deep Chinese coal seams. The model developed has been used to investigate the gas emission characteristics and the geological conditions that exist within the Huaibei coal mining region, Anhui province, China. The coal seams in this region exhibit a high incidence of coal and gas outbursts. An analysis of the results obtained from an initial application of an FTA model, identified eight dominant model parameters related to the gas content or geological conditions of the coal seams, which characterize the potential risk of in situ coal and gas outbursts. The eight dominant model parameters identified by the FTA method were subsequently used as input variables to an ANN model. The results produced by the ANN model were used to develop a qualitative risk index to characterize the potential risk level of occurrence of coal and gas outburst events. Four different potential risk alarm levels were defined: SAFE, POTENTIAL, HIGH and STRONG. Solutions to the prediction model were obtained using a combination of quantitative and qualitative data including the gas content or gas pressure and the geological and geotechnical conditions of coal seams. The application of this combined solution method identified more explicit and accurate model relationships between the in situ geological conditions and the potential risk of coal and gas outbursts. An analysis of the model solutions concluded that the coupled FTA and ANN model may offer a reliable alternative method to forecast the potential risk of coal and gas outbursts. (author)

  11. Decision tree based knowledge acquisition and failure diagnosis using a PWR loop vibration model

    International Nuclear Information System (INIS)

    Bauernfeind, V.; Ding, Y.

    1993-01-01

    An analytical vibration model of the primary system of a 1300 MW PWR was used for simulating mechanical faults. Deviations in the calculated power density spectra and coherence functions are determined and classified. The decision tree technique is then used for a personal computer supported knowledge presentation and for optimizing the logical relationships between the simulated faults and the observed symptoms. The optimized decision tree forms the knowledge base and can be used to diagnose known cases as well as to include new data into the knowledge base if new faults occur. (author)

  12. Dependencies in event trees analyzed by Petri nets

    International Nuclear Information System (INIS)

    Nývlt, Ondřej; Rausand, Marvin

    2012-01-01

    This paper discusses how non-marked Petri nets can be used to model and analyze event trees where the pivotal (branching) events are dependent and modeled by fault trees. The dependencies may, for example, be caused by shared utilities, shared components, or general common cause failures that are modeled by beta-factor models. These dependencies are cumbersome to take into account when using standard event-/fault tree modeling techniques, and may lead to significant errors in the calculated end-state probabilities of the event tree if they are not properly analyzed. A new approach is proposed in this paper, where the whole event tree is modeled by a non-marked Petri net and where P-invariants, representing the structural properties of the Petri net, are used to obtain the frequency of each end-state of the event tree with dependencies. The new approach is applied to a real example of an event tree analysis of the Strahov highway tunnel in Prague, Czech Republic, including two types of dependencies (shared Programmable Logic Controllers and Common Cause Failures). - Highlights: ► In this paper, we model and analyze event trees (ET) using Petri nets. ► The pivotal events of the modeled event trees are dependent (e.g., shared PLCs, CCF). ► A new method based on P-invariants to obtain probabilities of end states is proposed. ► Method is shown in the case study of the Stahov tunnel in the Czech Republic.

  13. SAP FLOW RESPONSE OF CHERRY TREES TO WEATHER CONDITION

    Directory of Open Access Journals (Sweden)

    Á. JUHÁSZ

    2011-03-01

    Full Text Available Sap flow response of cherry trees to weather condition. Themain goal of our study is to measure water-demand of cherry trees budded ontodifferent rootstocks by sapflow equipment and to study the sap flow response to themeteorological factors. The investigations are carried out in Soroksár in Hungary at‘Rita’ sweet cherry orchard. The pattern of sapflow was analyzed in relation ofsolar radiation, vapour pressure deficit and air temperature. Between solar radiationand sap flow was found a parabolic relation, daily pattern of sapflow is in closerelation (cubic also to vapour pressure deficit. No significant relationship existedbetween sapflow and air temperature. The sapflow performance of sweet cherrytrees on different rootstocks showed typical daily characters.

  14. A Novel Method for Detection and Classification of Covered Conductor Faults

    Directory of Open Access Journals (Sweden)

    Stanislav Misak

    2016-01-01

    Full Text Available Medium-Voltage (MV overhead lines with Covered Conductors (CCs are increasingly being used around the world primarily in forested or dissected terrain areas or in urban areas where it is not possible to utilize MV cable lines. The CC is specific in high operational reliability provided by the conductor core insulation compared to Aluminium-Conductor Steel-Reinforced (ACSR overhead lines. The only disadvantage of the CC is rather the problematic detection of faults compared to the ACSR. In this work, we consider the following faults: the contact of a tree branch with a CC and the fall of a conductor on the ground. The standard protection relays are unable to detect the faults and so the faults pose a risk for individuals in the vicinity of the conductor as well as it compromises the overall safety and reliability of the MV distribution system. In this article, we continue with our previous work aimed at the method enabling detection of the faults and we introduce a method enabling a classification of the fault type. Such a classification is especially important for an operator of an MV distribution system to plan the optimal maintenance or repair the faulty conductors since the fall of a tree branch can be solved later whereas the breakdown of a conductor means an immediate action of the operator.

  15. Tree condition and mortality following defoliation by the gypsy moth

    Science.gov (United States)

    Robert W. Campbell; Harry T. Valentine; Harry T. Valentine

    1972-01-01

    Relationships between expected defoliation and the subsequent condition and mortality rate among the defoliated trees are almost always important factors in deciding if, when, and where to take control action against a defoliator such as the gypsy moth, Porthetria dispar (L. )

  16. Descriptive statistics of tree crown condition in the Northeastern United States

    Science.gov (United States)

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Connecticut, Delaware, Maine, Maryland, Massachusetts, New...

  17. Methods for locating ground faults and insulation degradation condition in energy conversion systems

    Science.gov (United States)

    Agamy, Mohamed; Elasser, Ahmed; Galbraith, Anthony William; Harfman Todorovic, Maja

    2015-08-11

    Methods for determining a ground fault or insulation degradation condition within energy conversion systems are described. A method for determining a ground fault within an energy conversion system may include, in part, a comparison of baseline waveform of differential current to a waveform of differential current during operation for a plurality of DC current carrying conductors in an energy conversion system. A method for determining insulation degradation within an energy conversion system may include, in part, a comparison of baseline frequency spectra of differential current to a frequency spectra of differential current transient at start-up for a plurality of DC current carrying conductors in an energy conversion system. In one embodiment, the energy conversion system may be a photovoltaic system.

  18. Passive fault current limiting device

    Science.gov (United States)

    Evans, Daniel J.; Cha, Yung S.

    1999-01-01

    A passive current limiting device and isolator is particularly adapted for use at high power levels for limiting excessive currents in a circuit in a fault condition such as an electrical short. The current limiting device comprises a magnetic core wound with two magnetically opposed, parallel connected coils of copper, a high temperature superconductor or other electrically conducting material, and a fault element connected in series with one of the coils. Under normal operating conditions, the magnetic flux density produced by the two coils cancel each other. Under a fault condition, the fault element is triggered to cause an imbalance in the magnetic flux density between the two coils which results in an increase in the impedance in the coils. While the fault element may be a separate current limiter, switch, fuse, bimetal strip or the like, it preferably is a superconductor current limiter conducting one-half of the current load compared to the same limiter wired to carry the total current of the circuit. The major voltage during a fault condition is in the coils wound on the common core in a preferred embodiment.

  19. Increased water-use efficiency does not lead to enhanced tree growth under xeric and mesic conditions

    NARCIS (Netherlands)

    Lévesque, M.; Siegwolf, R.; Saurer, M.; Eilmann, B.; Rigling, A.

    2014-01-01

    Higher atmospheric CO2 concentrations (ca ) can under certain conditions increase tree growth by enhancing photosynthesis, resulting in an increase of intrinsic water-use efficiency (i WUE) in trees. However, the magnitude of these effects and their interactions with changing climatic conditions are

  20. Learning from examples - Generation and evaluation of decision trees for software resource analysis

    Science.gov (United States)

    Selby, Richard W.; Porter, Adam A.

    1988-01-01

    A general solution method for the automatic generation of decision (or classification) trees is investigated. The approach is to provide insights through in-depth empirical characterization and evaluation of decision trees for software resource data analysis. The trees identify classes of objects (software modules) that had high development effort. Sixteen software systems ranging from 3,000 to 112,000 source lines were selected for analysis from a NASA production environment. The collection and analysis of 74 attributes (or metrics), for over 4,700 objects, captured information about the development effort, faults, changes, design style, and implementation style. A total of 9,600 decision trees were automatically generated and evaluated. The trees correctly identified 79.3 percent of the software modules that had high development effort or faults, and the trees generated from the best parameter combinations correctly identified 88.4 percent of the modules on the average.

  1. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  2. Condition monitoring and fault diagnosis of motor bearings using undersampled vibration signals from a wireless sensor network

    Science.gov (United States)

    Lu, Siliang; Zhou, Peng; Wang, Xiaoxian; Liu, Yongbin; Liu, Fang; Zhao, Jiwen

    2018-02-01

    Wireless sensor networks (WSNs) which consist of miscellaneous sensors are used frequently in monitoring vital equipment. Benefiting from the development of data mining technologies, the massive data generated by sensors facilitate condition monitoring and fault diagnosis. However, too much data increase storage space, energy consumption, and computing resource, which can be considered fatal weaknesses for a WSN with limited resources. This study investigates a new method for motor bearings condition monitoring and fault diagnosis using the undersampled vibration signals acquired from a WSN. The proposed method, which is a fusion of the kurtogram, analog domain bandpass filtering, bandpass sampling, and demodulated resonance technique, can reduce the sampled data length while retaining the monitoring and diagnosis performance. A WSN prototype was designed, and simulations and experiments were conducted to evaluate the effectiveness and efficiency of the proposed method. Experimental results indicated that the sampled data length and transmission time of the proposed method result in a decrease of over 80% in comparison with that of the traditional method. Therefore, the proposed method indicates potential applications on condition monitoring and fault diagnosis of motor bearings installed in remote areas, such as wind farms and offshore platforms.

  3. Thinning of Tree Stands in the Arctic Zone of Krasnoyarsk Territory With Different Ecological Conditions

    Directory of Open Access Journals (Sweden)

    V. I. Polyakov

    2014-10-01

    Full Text Available In 2001 six permanent sample plots (PSP were established in forest stands differing in degrees of damage by pollution from the Norilsk industrial region. In 2004 the second forest inventory was carried out at these PSP for evaluation of pollutant impacts on stand condition changes. During both inventory procedures the vigor state of every tree was visually categorized according to 6-points scale of «Forest health regulations in Russian Federation». The changeover of tree into fall was also taken into account. Two types of Markov’s models simulating thinning process in tree stands within different ecological conditions has been developed: 1 based on assessment for probability of tree survival during three years; 2 in terms of evaluation of matrix for probability on change of vigor state category in the same period. The reconstruction of tree mortality from 1979 after industrial complex «Nadezda» setting into operation was realized on the basis of probability estimation of dead standing trees conservation during three years observed. The forecast of situation was carried out up to 2030. Using logistic regression the probability of tree survival was established depending on four factors: degree of tree damage by pollutants, tree species, stand location in relief and tree age. The acquired results make it possible to single out an impact of pollutants to tree stands’ resistance from other factors. There was revealed the percent of tree fall, resulted by pollution. The evaluation scale of SO2 gas resistance of tree species was constructed: birch, spruce, larch. Larch showed the highest percent of fall because of pollution.

  4. Fault-tolerant cooperative output regulation for multi-vehicle systems with sensor faults

    Science.gov (United States)

    Qin, Liguo; He, Xiao; Zhou, D. H.

    2017-10-01

    This paper presents a unified framework of fault diagnosis and fault-tolerant cooperative output regulation (FTCOR) for a linear discrete-time multi-vehicle system with sensor faults. The FTCOR control law is designed through three steps. A cooperative output regulation (COR) controller is designed based on the internal mode principle when there are no sensor faults. A sufficient condition on the existence of the COR controller is given based on the discrete-time algebraic Riccati equation (DARE). Then, a decentralised fault diagnosis scheme is designed to cope with sensor faults occurring in followers. A residual generator is developed to detect sensor faults of each follower, and a bank of fault-matching estimators are proposed to isolate and estimate sensor faults of each follower. Unlike the current distributed fault diagnosis for multi-vehicle systems, the presented decentralised fault diagnosis scheme in each vehicle reduces the communication and computation load by only using the information of the vehicle. By combing the sensor fault estimation and the COR control law, an FTCOR controller is proposed. Finally, the simulation results demonstrate the effectiveness of the FTCOR controller.

  5. Verification of the machinery condition monitoring technology by fault simulation tests

    International Nuclear Information System (INIS)

    Maehara, Takafumi; Watanabe, Yukio; Osaki, Kenji; Higuma, Koji; Nakano, Tomohito

    2009-01-01

    This paper shows the test items and equipments introduced by Japan Nuclear Energy Safety Organization to establish the monitoring technique for machinery conditions. From the result of vertical pump simulation tests, it was confirmed that fault analysis was impossible by measuring the accelerations on both motor and pump column pipes, however, was possible by measuring of pump shaft vibrations. Because hydraulic whirls by bearing wear had significant influences over bearing misalignments and flow rates, the monitoring trends must be done under the same condition (on bearing alignments and flow rates). We have confirmed that malfunctions of vertical pumps can be diagnosed using measured shaft vibration by ultrasonic sensors from outer surface of pump casing on the floor. (author)

  6. Fault locator of an allyl chloride plant

    Directory of Open Access Journals (Sweden)

    Savković-Stevanović Jelenka B.

    2004-01-01

    Full Text Available Process safety analysis, which includes qualitative fault event identification, the relative frequency and event probability functions, as well as consequence analysis, was performed on an allye chloride plant. An event tree for fault diagnosis and cognitive reliability analysis, as well as a troubleshooting system, were developed. Fuzzy inductive reasoning illustrated the advantages compared to crisp inductive reasoning. A qualitative model forecast the future behavior of the system in the case of accident detection and then compared it with the actual measured data. A cognitive model including qualitative and quantitative information by fuzzy logic of the incident scenario was derived as a fault locator for an ally! chloride plant. The obtained results showed the successful application of cognitive dispersion modeling to process safety analysis. A fuzzy inductive reasoner illustrated good performance to discriminate between different types of malfunctions. This fault locator allowed risk analysis and the construction of a fault tolerant system. This study is the first report in the literature showing the cognitive reliability analysis method.

  7. Diagnosis of three types of constant faults in read-once contact networks over finite bases

    KAUST Repository

    Busbait, Monther I.; Moshkov, Mikhail

    2016-01-01

    We study the depth of decision trees for diagnosis of three types of constant faults in read-once contact networks over finite bases containing only indecomposable networks. For each basis and each type of faults, we obtain a linear upper bound

  8. Methodology for Designing Fault-Protection Software

    Science.gov (United States)

    Barltrop, Kevin; Levison, Jeffrey; Kan, Edwin

    2006-01-01

    A document describes a methodology for designing fault-protection (FP) software for autonomous spacecraft. The methodology embodies and extends established engineering practices in the technical discipline of Fault Detection, Diagnosis, Mitigation, and Recovery; and has been successfully implemented in the Deep Impact Spacecraft, a NASA Discovery mission. Based on established concepts of Fault Monitors and Responses, this FP methodology extends the notion of Opinion, Symptom, Alarm (aka Fault), and Response with numerous new notions, sub-notions, software constructs, and logic and timing gates. For example, Monitor generates a RawOpinion, which graduates into Opinion, categorized into no-opinion, acceptable, or unacceptable opinion. RaiseSymptom, ForceSymptom, and ClearSymptom govern the establishment and then mapping to an Alarm (aka Fault). Local Response is distinguished from FP System Response. A 1-to-n and n-to- 1 mapping is established among Monitors, Symptoms, and Responses. Responses are categorized by device versus by function. Responses operate in tiers, where the early tiers attempt to resolve the Fault in a localized step-by-step fashion, relegating more system-level response to later tier(s). Recovery actions are gated by epoch recovery timing, enabling strategy, urgency, MaxRetry gate, hardware availability, hazardous versus ordinary fault, and many other priority gates. This methodology is systematic, logical, and uses multiple linked tables, parameter files, and recovery command sequences. The credibility of the FP design is proven via a fault-tree analysis "top-down" approach, and a functional fault-mode-effects-and-analysis via "bottoms-up" approach. Via this process, the mitigation and recovery strategy(s) per Fault Containment Region scope (width versus depth) the FP architecture.

  9. SCENARIO OF AN ACCIDENT OF SOIL DAMS IN CASE OF WATER SPILL OVER A DAM CREST BY USING FAULT TREE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Kuznetsov Dmitriy Viktorovich

    2016-04-01

    Full Text Available The scenario of a hydrodynamic accident of water flow over a crest of a soil dam is considered by the method of fault tree analysis, for which the basic reasons and controlled diagnostic indicators of an accident have been defined. Logical operators “AND”/”OR” were used for creation of a sequence of logically connected events, leading to an undesired event in the scenario of accident. The scenario of the accident was plotted in case of three basic reasons - an excessive settling of a dam crest, an excess flood, an inoperable spillway, taking into account the sequence of the events’ development and with observance of the necessary conditions leading to an accident. “Technical” reasons were observed in the present scenario, force majeure events were not considered. The provided scenario of the accident consists of two branches of events’ development: the left one that depends on an upstream level, and the right one that depends on settling of a dam crest. In each of the considered events an accident “the water spill over a crest of a soil dam” is possible only in case of execution of two different conditions at the same time, i.e. in case of an appropriate upstream level and the appropriate mark of a crest of a soil dam. The conditions of the accident are defined by diagnostic indices - the upstream level and settling of a dam crest, which at the same time are safety criteria of the hydraulic structure for soil dams. They allow defining the technical condition of the construction. Four possible technical conditions are suggested for the definition of technical statuses - normative, operable, limited operable, abnormal. Criteria of safety are the boundaries of the state: for loading and impact - it is the upstream level, for geometrical compliance of the construction - it is a dam crest mark.

  10. Probabilistic risk analysis and fault trees: Initial discussion of application to identification of risk at a wellhead

    Science.gov (United States)

    Rodak, C.; Silliman, S.

    2012-02-01

    Wellhead protection is of critical importance for managing groundwater resources. While a number of previous authors have addressed questions related to uncertainties in advective capture zones, methods for addressing wellhead protection in the presence of uncertainty in the chemistry of groundwater contaminants, the relationship between land-use and contaminant sources, and the impact on health of the receiving population are limited. It is herein suggested that probabilistic risk analysis (PRA) combined with fault trees (FT) provides a structure whereby chemical transport can be combined with uncertainties in source, chemistry, and health impact to assess the probability of negative health outcomes in the population. As such, PRA-FT provides a new strategy for the identification of areas of probabilistically high human health risk. Application of this approach is demonstrated through a simplified case study involving flow to a well in an unconfined aquifer with heterogeneity in aquifer properties and contaminant sources.

  11. Design of a real-time fault diagnosis expert system for the EAST cryoplant

    International Nuclear Information System (INIS)

    Zhou Zhiwei; Zhuang Ming; Lu Xiaofei; Hu Liangbing; Xia Genhai

    2012-01-01

    Highlights: ► An expert system of real-time fault diagnosis for EAST cryoplant is designed. ► Knowledge base is built via fault tree analysis based on our fault experience. ► It can make up the deficiency of safety monitoring in cryogenic DCS. ► It can help operators to find the fault causes and give operation suggestion. ► It plays a role of operators training in certain degree. - Abstract: The EAST cryoplant consists of a 2 kW/4 K helium refrigerator and a helium distribution system. It is a complex process system which involves many process variables and cryogenic equipments. Each potential fault or abnormal event may influence stability and safety of the cryogenic system, thereby disturbing the fusion experiment. The cryogenic control system can monitor the process data and detect process alarms, but it is difficult to effectively diagnose the fault causes and provide operation suggestions to operators when anomalies occur. Therefore, a real-time fault diagnosis expert system is essential for a safe and steady operation of EAST cryogenic system. After a brief description of the EAST cryoplant and its control system, the structure design of the cryogenic fault diagnosis expert system is proposed. Based on the empirical knowledge, the fault diagnosis model is built adopting fault tree analysis method which considers the uncertainty. The knowledge base and the inference machine are presented in detail. A cross-platform integrated development environment Qt Creator and MySQL database have been used to develop the system. The proposed expert system has a fine graphic user interface for monitoring and operation. Preliminary test was conducted and the results found to be satisfactory.

  12. Study on Practical Application of Turboprop Engine Condition Monitoring and Fault Diagnostic System Using Fuzzy-Neuro Algorithms

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong; Kim, Keunwoo

    2013-03-01

    The Neural Networks is mostly used to engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measuring performance data, and proposes a fault diagnostic system using the base performance model and artificial intelligent methods such as Fuzzy and Neural Networks. Each real engine performance model, which is named as the base performance model that can simulate a new engine performance, is inversely made using its performance test data. Therefore the condition monitoring of each engine can be more precisely carried out through comparison with measuring performance data. The proposed diagnostic system identifies firstly the faulted components using Fuzzy Logic, and then quantifies faults of the identified components using Neural Networks leaned by fault learning data base obtained from the developed base performance model. In leaning the measuring performance data of the faulted components, the FFBP (Feed Forward Back Propagation) is used. In order to user's friendly purpose, the proposed diagnostic program is coded by the GUI type using MATLAB.

  13. Determination of minimum sample size for fault diagnosis of automobile hydraulic brake system using power analysis

    Directory of Open Access Journals (Sweden)

    V. Indira

    2015-03-01

    Full Text Available Hydraulic brake in automobile engineering is considered to be one of the important components. Condition monitoring and fault diagnosis of such a component is very essential for safety of passengers, vehicles and to minimize the unexpected maintenance time. Vibration based machine learning approach for condition monitoring of hydraulic brake system is gaining momentum. Training and testing the classifier are two important activities in the process of feature classification. This study proposes a systematic statistical method called power analysis to find the minimum number of samples required to train the classifier with statistical stability so as to get good classification accuracy. Descriptive statistical features have been used and the more contributing features have been selected by using C4.5 decision tree algorithm. The results of power analysis have also been verified using a decision tree algorithm namely, C4.5.

  14. A Bypass-Ring Scheme for a Fault Tolerant Multicast

    Directory of Open Access Journals (Sweden)

    V. Dynda

    2003-01-01

    Full Text Available We present a fault tolerant scheme for recovery from single or multiple node failures in multi-directional multicast trees. The scheme is based on cyclic structures providing alternative paths to eliminate faulty nodes and reroute the traffic. Our scheme is independent of message source and direction in the tree, provides a basis for on-the-fly repair and can be used as a platform for various strategies for reconnecting tree partitions. It only requires an underlying infrastructure to provide a reliable routing service. Although it is described in the context of a message multicast, the scheme can be used universally in all systems using tree-based overlay networks for communication among components.

  15. Passive Fault-tolerant Control of Discrete-time Piecewise Affine Systems against Actuator Faults

    DEFF Research Database (Denmark)

    Tabatabaeipour, Seyed Mojtaba; Izadi-Zamanabadi, Roozbeh; Bak, Thomas

    2012-01-01

    In this paper, we propose a new method for passive fault-tolerant control of discrete time piecewise affine systems. Actuator faults are considered. A reliable piecewise linear quadratic regulator (LQR) state feedback is designed such that it can tolerate actuator faults. A sufficient condition f...... is illustrated on a numerical example and a two degree of freedom helicopter....

  16. Fault-tree analysis for probabilistic assessment of radioactive-waste segregation: an application to a plastic clay formation at a specific site

    International Nuclear Information System (INIS)

    D'Alessandro, M.; Bonne, A.

    1982-01-01

    This study concerns a probabilistic safety analysis of potential nuclear-waste repository which may be mined into a Tertiary clay formation underlying the Nuclear Research Centre at Mol (Belgium). The value of the geological barrier has been analyzed in probabilistic terms through the application of the Fault-Tree Analysis (FTA) which can answer two main questions: how can the barrier fail (query) and what is the failure probability (query). FTA has been applied to conceptual radioactive-waste disposal systems. In this paper this methodology has been applied to a specific clay formation, to test the applicability of the procedure to a potential site. With this aim, release probabilities to three different receptors (groundwater, land surface, and atmosphere) were estimated for four different time periods. Because of obvious uncertainties in geology predictive capabilities, a probability band has been obtained. Faulting phenomena are among the main mechanisms having the potential to cause release to groundwater, whereas direct releases to land surface may be linked to various glacial phenomena; on short term, different types of human actions may be important. The overall failure probabilities seem to be sufficiently low to offer a good safety margin. (author)

  17. A LIDAR-Based Tree Canopy Characterization under Simulated Uneven Road Condition: Advance in Tree Orchard Canopy Profile Measurement

    Directory of Open Access Journals (Sweden)

    Yue Shen

    2017-01-01

    Full Text Available In real outdoor canopy profile detection, the accuracy of a LIDAR scanner to measure canopy structure is affected by a potentially uneven road condition. The level of error associated with attitude angles from undulations in the ground surface can be reduced by developing appropriate correction algorithm. This paper proposes an offline attitude angle offset correction algorithm based on a 3D affine coordinate transformation. The validity of the correction algorithm is verified by conducting an indoor experiment. The experiment was conducted on an especially designed canopy profile measurement platform. During the experiment, an artificial tree and a tree-shaped carved board were continuously scanned at constant laser scanner travel speed and detection distances under simulated bumpy road conditions. Acquired LIDAR laser scanner raw data was processed offline by exceptionally developed MATLAB program. The obtained results before and after correction method show that the single attitude angle offset correction method is able to correct the distorted data points in tree-shaped carved board profile measurement, with a relative error of 5%, while the compound attitude angle offset correction method is effective to reduce the error associated with compound attitude angle deviation from the ideal scanner pose, with relative error of 7%.

  18. The morphology of strike-slip faults - Examples from the San Andreas Fault, California

    Science.gov (United States)

    Bilham, Roger; King, Geoffrey

    1989-01-01

    The dilatational strains associated with vertical faults embedded in a horizontal plate are examined in the framework of fault kinematics and simple displacement boundary conditions. Using boundary element methods, a sequence of examples of dilatational strain fields associated with commonly occurring strike-slip fault zone features (bends, offsets, finite rupture lengths, and nonuniform slip distributions) is derived. The combinations of these strain fields are then used to examine the Parkfield region of the San Andreas fault system in central California.

  19. Design of a real-time fault diagnosis expert system for the EAST cryoplant

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Zhiwei, E-mail: zzw@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Zhuang Ming, E-mail: zhm@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Lu Xiaofei, E-mail: luxf1212@mail.ustc.edu.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Hu Liangbing, E-mail: huliangbing@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Xia Genhai, E-mail: xgh@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer An expert system of real-time fault diagnosis for EAST cryoplant is designed. Black-Right-Pointing-Pointer Knowledge base is built via fault tree analysis based on our fault experience. Black-Right-Pointing-Pointer It can make up the deficiency of safety monitoring in cryogenic DCS. Black-Right-Pointing-Pointer It can help operators to find the fault causes and give operation suggestion. Black-Right-Pointing-Pointer It plays a role of operators training in certain degree. - Abstract: The EAST cryoplant consists of a 2 kW/4 K helium refrigerator and a helium distribution system. It is a complex process system which involves many process variables and cryogenic equipments. Each potential fault or abnormal event may influence stability and safety of the cryogenic system, thereby disturbing the fusion experiment. The cryogenic control system can monitor the process data and detect process alarms, but it is difficult to effectively diagnose the fault causes and provide operation suggestions to operators when anomalies occur. Therefore, a real-time fault diagnosis expert system is essential for a safe and steady operation of EAST cryogenic system. After a brief description of the EAST cryoplant and its control system, the structure design of the cryogenic fault diagnosis expert system is proposed. Based on the empirical knowledge, the fault diagnosis model is built adopting fault tree analysis method which considers the uncertainty. The knowledge base and the inference machine are presented in detail. A cross-platform integrated development environment Qt Creator and MySQL database have been used to develop the system. The proposed expert system has a fine graphic user interface for monitoring and operation. Preliminary test was conducted and the results found to be satisfactory.

  20. [Prediction of the total Japanese cedar pollen counts based on male flower-setting conditions of standard trees].

    Science.gov (United States)

    Yuta, Atsushi; Ukai, Kotaro; Sakakura, Yasuo; Tani, Hideshi; Matsuda, Fukiko; Yang, Tian-qun; Majima, Yuichi

    2002-07-01

    We made a prediction of the Japanese cedar (Cryptomeria japonica) pollen counts at Tsu city based on male flower-setting conditions of standard trees. The 69 standard trees from 23 kinds of clones, planted at Mie Prefecture Science and Technology Promotion Center (Hakusan, Mie) in 1964, were selected. Male flower-setting conditions for 276 faces (69 trees x 4 points of the compass) were scored from 0 to 3. The average of scores and total pollen counts from 1988 to 2000 was analyzed. As the results, the average scores from standard trees and total pollen counts except two mass pollen-scattered years in 1995 and 2000 had a positive correlation (r = 0.914) by linear function. On the mass pollen-scattered years, pollen counts were influenced from the previous year. Therefore, the score of the present year minus that of the previous year were used for analysis. The average scores from male flower-setting conditions and pollen counts had a strong positive correlation (r = 0.994) when positive scores by taking account of the previous year were analyzed. We conclude that prediction of pollen counts are possible based on the male flower-setting conditions of standard trees.

  1. Descriptive statistics of tree crown condition in the North Central United States

    Science.gov (United States)

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Illinois, Indiana, Michigan, Minnesota, Missouri, and Wisconsin...

  2. Responses of Tree Growths to Tree Size, Competition, and Topographic Conditions in Sierra Nevada Forests Using Bi-temporal Airborne LiDAR Data

    Science.gov (United States)

    Ma, Q.; Su, Y.; Tao, S.; Guo, Q.

    2016-12-01

    Trees in the Sierra Nevada (SN) forests are experiencing rapid changes due to human disturbances and climatic changes. An improved monitoring of tree growth and understanding of how tree growth responses to different impact factors, such as tree competition, forest density, topographic and hydrologic conditions, are urgently needed in tree growth modeling. Traditional tree growth modeling mainly relied on field survey, which was highly time-consuming and labor-intensive. Airborne Light detection and ranging System (ALS) is increasingly used in forest survey, due to its high efficiency and accuracy in three-dimensional tree structure delineation and terrain characterization. This study successfully detected individual tree growth in height (ΔH), crown area (ΔA), and crown volume (ΔV) over a five-year period (2007-2012) using bi-temporal ALS data in two conifer forest areas in SN. We further analyzed their responses to original tree size, competition indices, forest structure indices, and topographic environmental parameters at individual tree and forest stand scales. Our results indicated ΔH was strongly sensitive to topographic wetness index; whereas ΔA and ΔV were highly responsive to forest density and original tree sizes. These ALS based findings in ΔH were consistent with field measurements. Our study demonstrated the promising potential of using bi-temporal ALS data in forest growth measurements and analysis. A more comprehensive study over a longer temporal period and a wider range of forest stands would give better insights into tree growth in the SN, and provide useful guides for forest growth monitoring, modeling, and management.

  3. Analysis and implementation of power management and control strategy for six-phase multilevel ac drive system in fault condition

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2016-03-01

    Full Text Available This research article exploits the power management algorithm in post-fault conditions for a six-phase (quad multilevel inverter. The drive circuit consists of four 2-level, three-phase voltage source inverter (VSI supplying a six-phase open-end windings motor or/impedance load, with circumstantial failure of one VSI investigated. A simplified level-shifted pulse-width modulation (PWM algorithm is developed to modulate each couple of three-phase VSI as 3-level output voltage generators in normal operation. The total power of the whole ac drive is shared equally among the four isolated DC sources. The developed post-fault algorithm is applied when there is a fault by one VSI and the load is fed from the remaining three healthy VSIs. In faulty conditions the multilevel outputs are reduced from 3-level to 2-level, but still the system propagates with degraded power. Numerical simulation modelling and experimental tests have been carried out with proposed post-fault control algorithm with three-phase open-end (asymmetrical induction motor/R-L impedance load. A complete set of simulation and experimental results provided in this paper shows close agreement with the developed theoretical background.

  4. Analysis and implementation of power managment and control strategy for six-phase multilevel ac drive system in fault condition

    DEFF Research Database (Denmark)

    Sanjeevikumar, P.; Grandi, Gabriele; Blaabjerg, Frede

    2016-01-01

    sources. The developed post-fault algorithm is applied when there is a fault by one VSI and the load is fed from the remaining three healthy VSIs. In faulty conditions the multilevel outputs are reduced from 3-level to 2-level, but still the system propagates with degraded power. Numerical simulation......This research article exploits the power management algorithm in post-fault conditions for a six-phase (quad) multilevel inverter. The drive circuit consists of four 2-level, three-phase voltage source inverter (VSI) supplying a six-phase open-end windings motor or/impedance load......, with circumstantial failure of one VSI investigated. A simplified level-shifted pulse-width modulation (PWM) algorithm is developed to modulate each couple of three-phase VSI as 3-level output voltage generators in normal operation. The total power of the whole ac drive is shared equally among the four isolated DC...

  5. Application of an expert system for real time diagnosis of the limiting conditions for operation in nuclear power plants

    International Nuclear Information System (INIS)

    Paiva, Gustavo Varanda; Schirru, Roberto

    2015-01-01

    In the history of nuclear power plants operation safety is an important factor to be considered and for this, the use of resistant materials and the application of redundant systems are used to make a plant with high reliability. Through the acquisition of experience with time and accidents that happened in the area, it was observed that the importance of creating methods that simplify the operator work in making decisions in accidents scenarios is an important factor in ensuring the safety of nuclear power plants. This work aims to create a program made with the Python language, which with the use of an expert systems be able to apply, in real time, the rules contained in the Limiting Conditions for Operation (LCO) and tell to the operator the occurrence of any limiting conditions and the occurrence of failure to perform the require actions in the time to completion. The generic structure used to represent the knowledge of the expert system was a fault tree where the events of this tree are objects in program. To test the accuracy of the program a simplified model of a fault tree was used that represents the LCO of the nuclear power station named Central Nuclear Almirante Alvaro Alberto 1. With the results obtained in the analysis of the simplified model it was observed a significant reduction in the time to identify the LCO, showing that the implementation of this program to more complex models of fault tree would be viable.(author)

  6. Application of an expert system for real time diagnosis of the limiting conditions for operation in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Gustavo Varanda; Schirru, Roberto, E-mail: gustavopaiva@poli.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (brazil). Programa de Engenharia Nuclear

    2015-07-01

    In the history of nuclear power plants operation safety is an important factor to be considered and for this, the use of resistant materials and the application of redundant systems are used to make a plant with high reliability. Through the acquisition of experience with time and accidents that happened in the area, it was observed that the importance of creating methods that simplify the operator work in making decisions in accidents scenarios is an important factor in ensuring the safety of nuclear power plants. This work aims to create a program made with the Python language, which with the use of an expert systems be able to apply, in real time, the rules contained in the Limiting Conditions for Operation (LCO) and tell to the operator the occurrence of any limiting conditions and the occurrence of failure to perform the require actions in the time to completion. The generic structure used to represent the knowledge of the expert system was a fault tree where the events of this tree are objects in program. To test the accuracy of the program a simplified model of a fault tree was used that represents the LCO of the nuclear power station named Central Nuclear Almirante Alvaro Alberto 1. With the results obtained in the analysis of the simplified model it was observed a significant reduction in the time to identify the LCO, showing that the implementation of this program to more complex models of fault tree would be viable.(author)

  7. Descriptive statistics of tree crown condition in the United States Interior West

    Science.gov (United States)

    KaDonna C. Randolph; Mike T. Thompson

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Colorado, Idaho, Nevada, Utah, and Wyoming between 1996 and...

  8. The integration methods of fuzzy fault mode and effect analysis and fault tree analysis for risk analysis of yogurt production

    Science.gov (United States)

    Aprilia, Ayu Rizky; Santoso, Imam; Ekasari, Dhita Murita

    2017-05-01

    Yogurt is a product based on milk, which has beneficial effects for health. The process for the production of yogurt is very susceptible to failure because it involves bacteria and fermentation. For an industry, the risks may cause harm and have a negative impact. In order for a product to be successful and profitable, it requires the analysis of risks that may occur during the production process. Risk analysis can identify the risks in detail and prevent as well as determine its handling, so that the risks can be minimized. Therefore, this study will analyze the risks of the production process with a case study in CV.XYZ. The method used in this research is the Fuzzy Failure Mode and Effect Analysis (fuzzy FMEA) and Fault Tree Analysis (FTA). The results showed that there are 6 risks from equipment variables, raw material variables, and process variables. Those risks include the critical risk, which is the risk of a lack of an aseptic process, more specifically if starter yogurt is damaged due to contamination by fungus or other bacteria and a lack of sanitation equipment. The results of quantitative analysis of FTA showed that the highest probability is the probability of the lack of an aseptic process, with a risk of 3.902%. The recommendations for improvement include establishing SOPs (Standard Operating Procedures), which include the process, workers, and environment, controlling the starter of yogurt and improving the production planning and sanitation equipment using hot water immersion.

  9. French Contribution to the Specialists' Meeting on Demonstration of Structural Integrity under Normal and Fault Conditions

    International Nuclear Information System (INIS)

    Soulat, P.; Tavassoli, A.

    1981-01-01

    The following is a summary of a few selected programmes in France on the structural integrity of fast reactor components under normal and faulted conditions. The scope of the programmes selected is limited to that suggested by the specialists Meeting organisers

  10. An Intelligent Gear Fault Diagnosis Methodology Using a Complex Wavelet Enhanced Convolutional Neural Network.

    Science.gov (United States)

    Sun, Weifang; Yao, Bin; Zeng, Nianyin; Chen, Binqiang; He, Yuchao; Cao, Xincheng; He, Wangpeng

    2017-07-12

    As a typical example of large and complex mechanical systems, rotating machinery is prone to diversified sorts of mechanical faults. Among these faults, one of the prominent causes of malfunction is generated in gear transmission chains. Although they can be collected via vibration signals, the fault signatures are always submerged in overwhelming interfering contents. Therefore, identifying the critical fault's characteristic signal is far from an easy task. In order to improve the recognition accuracy of a fault's characteristic signal, a novel intelligent fault diagnosis method is presented. In this method, a dual-tree complex wavelet transform (DTCWT) is employed to acquire the multiscale signal's features. In addition, a convolutional neural network (CNN) approach is utilized to automatically recognise a fault feature from the multiscale signal features. The experiment results of the recognition for gear faults show the feasibility and effectiveness of the proposed method, especially in the gear's weak fault features.

  11. Habitat conditions and phenological tree traits overrule the influence of tree genotype in the needle mycobiome-Picea glauca system at an arctic treeline ecotone.

    Science.gov (United States)

    Eusemann, Pascal; Schnittler, Martin; Nilsson, R Henrik; Jumpponen, Ari; Dahl, Mathilde B; Würth, David G; Buras, Allan; Wilmking, Martin; Unterseher, Martin

    2016-09-01

    Plant-associated mycobiomes in extreme habitats are understudied and poorly understood. We analysed Illumina-generated ITS1 sequences from the needle mycobiome of white spruce (Picea glauca) at the northern treeline in Alaska (USA). Sequences were obtained from the same DNA that was used for tree genotyping. In the present study, fungal metabarcoding and tree microsatellite data were compared for the first time. In general, neighbouring trees shared more fungal taxa with each other than trees growing in further distance. Mycobiomes correlated strongly with phenological host traits and local habitat characteristics contrasting a dense forest stand with an open treeline site. Genetic similarity between trees did not influence fungal composition and no significant correlation existed between needle mycobiome and tree genotype. Our results suggest the pronounced influence of local habitat conditions and phenotypic tree traits on needle-inhabiting fungi. By contrast, the tree genetic identity cannot be benchmarked as a dominant driver for needle-inhabiting mycobiomes, at least not for white spruce in this extreme environment. © 2016 The Authors. New Phytologist © 2016 New Phytologist Trust.

  12. Joint High-Order Synchrosqueezing Transform and Multi-Taper Empirical Wavelet Transform for Fault Diagnosis of Wind Turbine Planetary Gearbox under Nonstationary Conditions

    Directory of Open Access Journals (Sweden)

    Yue Hu

    2018-01-01

    Full Text Available Wind turbines usually operate under nonstationary conditions, such as wide-range speed fluctuation and time-varying load. Its critical component, the planetary gearbox, is prone to malfunction or failure, which leads to downtime and repair costs. Therefore, fault diagnosis and condition monitoring for the planetary gearbox in wind turbines is a vital research topic. Meanwhile, the signals measured by the vibration sensors mounted in the gearbox exhibit time-varying and nonstationary features. In this study, a novel time-frequency method based on high-order synchrosqueezing transform (SST and multi-taper empirical wavelet transform (MTEWT is proposed for the wind turbine planetary gearbox under nonstationary conditions. The high-order SST uses accurate instantaneous frequency approximations to obtain a sharper time-frequency representation (TFR. As the acquired signal consists of many components, like the meshing and rotating components of the gear and bearing, the fault component may be masked by other unrelated components. The MTEWT is used to separate the fault feature from the masking components. A variety of experimental signals of the wind turbine planetary gearbox under nonstationary conditions have been analyzed to demonstrate the effectiveness and robustness of the proposed method. Results show that the proposed method is effective in diagnosing both gear and bearing faults.

  13. Joint High-Order Synchrosqueezing Transform and Multi-Taper Empirical Wavelet Transform for Fault Diagnosis of Wind Turbine Planetary Gearbox under Nonstationary Conditions.

    Science.gov (United States)

    Hu, Yue; Tu, Xiaotong; Li, Fucai; Meng, Guang

    2018-01-07

    Wind turbines usually operate under nonstationary conditions, such as wide-range speed fluctuation and time-varying load. Its critical component, the planetary gearbox, is prone to malfunction or failure, which leads to downtime and repair costs. Therefore, fault diagnosis and condition monitoring for the planetary gearbox in wind turbines is a vital research topic. Meanwhile, the signals measured by the vibration sensors mounted in the gearbox exhibit time-varying and nonstationary features. In this study, a novel time-frequency method based on high-order synchrosqueezing transform (SST) and multi-taper empirical wavelet transform (MTEWT) is proposed for the wind turbine planetary gearbox under nonstationary conditions. The high-order SST uses accurate instantaneous frequency approximations to obtain a sharper time-frequency representation (TFR). As the acquired signal consists of many components, like the meshing and rotating components of the gear and bearing, the fault component may be masked by other unrelated components. The MTEWT is used to separate the fault feature from the masking components. A variety of experimental signals of the wind turbine planetary gearbox under nonstationary conditions have been analyzed to demonstrate the effectiveness and robustness of the proposed method. Results show that the proposed method is effective in diagnosing both gear and bearing faults.

  14. Study of the reliability of the Auxiliary Feedwater System of a LWR nuclear power plant through the Fault Tree and Bayesian Network; Estudo de confiabilidade do Sistema Auxiliar de Agua de Alimentacao de uma central nuclear a agua leve por arvore de falhas e rede Bayesiana

    Energy Technology Data Exchange (ETDEWEB)

    Lava, Deise Diana

    2016-10-01

    This paper aims to present a study of the reliability of the Auxiliary Feedwater System (AFWS) through the methods of Fault Tree and Bayesian Network. Therefore, the paper consists of a literature review of the history of nuclear energy and the methodologies used. The AFWS is responsible for providing water system to cool the secondary circuit of nuclear reactors of the PWR type when normal feeding water system failure. How this system operates only when the primary system fails, it is expected that the AFWS failure probability is very low. The AFWS failure probability is divided into two cases: the first is the probability of failure in the first eight hours of operation and the second is the probability of failure after eight hours of operation, considering that the system has not failed within the first eight hours. The calculation of the probability of failure of the second case was made through the use of Fault Tree and Bayesian Network, that it was constructed from the Fault Tree. The results of the failure probability obtained were very close, on the order of 10{sup -3}. (author)

  15. SOFT TREE: Fault Tree Technique as Applied to Software. Revision.

    Science.gov (United States)

    1983-10-01

    13 12 - 16 03 - 18 09 - 19 01 - 19 02 - 19 03 - 19 05 18. Con’t Non- Nuclear Munition, Non- Nuclear Munition Safety, Fuze Safety, Microprocessor...costucin the’ V’Y wvSoft Tree be ver fam-’il~. iar-a’--. that te persnns conihhsutnge thoftd refec be very familia wthipeetino microprocessosor atd idotwee h...ro 7- qSf" fart~b -To WA0 IFu t TOC6Lf e aF ’t9 q-EN rNz Al fC1~ATOk -1- 1AP6AG $ LA ? To.~ Yujiif’ ToA4. IWOv~:EAii CI~t~J~13Lf ToP5M A~E F CAP Avrif

  16. Fault detection and fault tolerant control of a smart base isolation system with magneto-rheological damper

    International Nuclear Information System (INIS)

    Wang, Han; Song, Gangbing

    2011-01-01

    Fault detection and isolation (FDI) in real-time systems can provide early warnings for faulty sensors and actuator signals to prevent events that lead to catastrophic failures. The main objective of this paper is to develop FDI and fault tolerant control techniques for base isolation systems with magneto-rheological (MR) dampers. Thus, this paper presents a fixed-order FDI filter design procedure based on linear matrix inequalities (LMI). The necessary and sufficient conditions for the existence of a solution for detecting and isolating faults using the H ∞ formulation is provided in the proposed filter design. Furthermore, an FDI-filter-based fuzzy fault tolerant controller (FFTC) for a base isolation structure model was designed to preserve the pre-specified performance of the system in the presence of various unknown faults. Simulation and experimental results demonstrated that the designed filter can successfully detect and isolate faults from displacement sensors and accelerometers while maintaining excellent performance of the base isolation technology under faulty conditions

  17. Effect Analysis of Digital I and C Systems on Plant Safety based on Fault-Tree Analysis

    International Nuclear Information System (INIS)

    Lee, Seung Jun; Jung, Wondea

    2014-01-01

    Deterioration and an inadequate supply of components of analog I and C systems have led to inefficient and costly maintenance. Moreover, since the fast evolution of digital technology has enabled more reliable functions to be designed for NPP safety, the transition from analog to digital has been accelerated. Owing to the distinguishable characteristics of digital I and C systems, a reliability analysis of digital systems has become an important element of a probabilistic safety assessment (PSA). Digital I and C systems have unique characteristics such as fault-tolerant techniques and software. However, these features have not been properly considered yet in most NPP PSA models. The effect of digital I and C systems should be evaluated by comparing them to that of analog I and C systems. Before installing a digital I and C system, even though it is expected that the plant safety can be improved through the advantageous features of digital I and C systems, it should be validated whether the total NPP safety is better than analog systems or is the same at least. In this work, the fault-tree (FT) technique, which is most widely used in a PSA, was used to compare the effects of analog and digital I and C systems. From a case study, the results of plant safety were compared. In this work, the effect of a digital RPS was evaluated by comparing it to that of an analog RPS based on the FT models. In the evaluation results, it was observed that digital RPS has a positive effect on reducing the system unavailability. The analysis results can be used for the development of a guide for evaluating digital I and C systems and reliability requirements

  18. Fault size classification of rotating machinery using support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. S.; Lee, D. H.; Park, S. K. [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2012-03-15

    Studies on fault diagnosis of rotating machinery have been carried out to obtain a machinery condition in two ways. First is a classical approach based on signal processing and analysis using vibration and acoustic signals. Second is to use artificial intelligence techniques to classify machinery conditions into normal or one of the pre-determined fault conditions. Support Vector Machine (SVM) is well known as intelligent classifier with robust generalization ability. In this study, a two-step approach is proposed to predict fault types and fault sizes of rotating machinery in nuclear power plants using multi-class SVM technique. The model firstly classifies normal and 12 fault types and then identifies their sizes in case of predicting any faults. The time and frequency domain features are extracted from the measured vibration signals and used as input to SVM. A test rig is used to simulate normal and the well-know 12 artificial fault conditions with three to six fault sizes of rotating machinery. The application results to the test data show that the present method can estimate fault types as well as fault sizes with high accuracy for bearing an shaft-related faults and misalignment. Further research, however, is required to identify fault size in case of unbalance, rubbing, looseness, and coupling-related faults.

  19. Fault size classification of rotating machinery using support vector machine

    International Nuclear Information System (INIS)

    Kim, Y. S.; Lee, D. H.; Park, S. K.

    2012-01-01

    Studies on fault diagnosis of rotating machinery have been carried out to obtain a machinery condition in two ways. First is a classical approach based on signal processing and analysis using vibration and acoustic signals. Second is to use artificial intelligence techniques to classify machinery conditions into normal or one of the pre-determined fault conditions. Support Vector Machine (SVM) is well known as intelligent classifier with robust generalization ability. In this study, a two-step approach is proposed to predict fault types and fault sizes of rotating machinery in nuclear power plants using multi-class SVM technique. The model firstly classifies normal and 12 fault types and then identifies their sizes in case of predicting any faults. The time and frequency domain features are extracted from the measured vibration signals and used as input to SVM. A test rig is used to simulate normal and the well-know 12 artificial fault conditions with three to six fault sizes of rotating machinery. The application results to the test data show that the present method can estimate fault types as well as fault sizes with high accuracy for bearing an shaft-related faults and misalignment. Further research, however, is required to identify fault size in case of unbalance, rubbing, looseness, and coupling-related faults

  20. Groundwater decline and tree change in floodplain landscapes: Identifying non-linear threshold responses in canopy condition

    Directory of Open Access Journals (Sweden)

    J. Kath

    2014-12-01

    Full Text Available Groundwater decline is widespread, yet its implications for natural systems are poorly understood. Previous research has revealed links between groundwater depth and tree condition; however, critical thresholds which might indicate ecological ‘tipping points’ associated with rapid and potentially irreversible change have been difficult to quantify. This study collated data for two dominant floodplain species, Eucalyptus camaldulensis (river red gum and E. populnea (poplar box from 118 sites in eastern Australia where significant groundwater decline has occurred. Boosted regression trees, quantile regression and Threshold Indicator Taxa Analysis were used to investigate the relationship between tree condition and groundwater depth. Distinct non-linear responses were found, with groundwater depth thresholds identified in the range from 12.1 m to 22.6 m for E. camaldulensis and 12.6 m to 26.6 m for E. populnea beyond which canopy condition declined abruptly. Non-linear threshold responses in canopy condition in these species may be linked to rooting depth, with chronic groundwater decline decoupling trees from deep soil moisture resources. The quantification of groundwater depth thresholds is likely to be critical for management aimed at conserving groundwater dependent biodiversity. Identifying thresholds will be important in regions where water extraction and drying climates may contribute to further groundwater decline. Keywords: Canopy condition, Dieback, Drought, Tipping point, Ecological threshold, Groundwater dependent ecosystems

  1. An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2016-04-01

    Full Text Available In recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. In order to improve the fault-tolerance and dynamic response capability under asymmetrical grid fault conditions, an optimal integrated control scheme for the grid-side voltage-source converter (VSC of direct-driven permanent magnet synchronous generator (PMSG-based wind turbine systems is proposed in this paper. The optimal control strategy includes a main controller and an additional controller. In the main controller, a double-loop controller based on differential flatness-based theory is designed for grid-side VSC. Two parts are involved in the design process of the flatness-based controller: the reference trajectories generation of flatness output and the implementation of the controller. In the additional control aspect, an auxiliary second harmonic compensation control loop based on an improved calculation method for grid-side instantaneous transmission power is designed by the quasi proportional resonant (Quasi-PR control principle, which is able to simultaneously restrain the second harmonic components in active power and reactive power injected into the grid without the respective calculation for current control references. Moreover, to reduce the DC-link overvoltage during grid faults, the mathematical model of DC-link voltage is analyzed and a feedforward modified control factor is added to the traditional DC voltage control loop in grid-side VSC. The effectiveness of the optimal control scheme is verified in PSCAD/EMTDC simulation software.

  2. Identifiability of Additive Actuator and Sensor Faults by State Augmentation

    Science.gov (United States)

    Joshi, Suresh; Gonzalez, Oscar R.; Upchurch, Jason M.

    2014-01-01

    A class of fault detection and identification (FDI) methods for bias-type actuator and sensor faults is explored in detail from the point of view of fault identifiability. The methods use state augmentation along with banks of Kalman-Bucy filters for fault detection, fault pattern determination, and fault value estimation. A complete characterization of conditions for identifiability of bias-type actuator faults, sensor faults, and simultaneous actuator and sensor faults is presented. It is shown that FDI of simultaneous actuator and sensor faults is not possible using these methods when all sensors have unknown biases. The fault identifiability conditions are demonstrated via numerical examples. The analytical and numerical results indicate that caution must be exercised to ensure fault identifiability for different fault patterns when using such methods.

  3. Assessing the damage importance rank in acoustic diagnostics of technical conditions of the internal combustion engine with multi-valued logical decision trees

    Directory of Open Access Journals (Sweden)

    Deptuła Adam

    2017-01-01

    Full Text Available This paper presents possible applications of acoustic diagnostics in inspecting the technical condition of an internal combustion engine with autoignition on the example of the Fiat drive unit with the common rail system. As a result of measuring the sound pressure level for specific faults and comparing the noise generated by the motor running smoothly, the detailed maps of changes in the acoustic spectrum may be generated. These results may be helpful in future diagnostics of internal combustion engines. In the paper, we present the results from the scientific works in the area of research, design and operation of internal combustion engines, conducted at the Department of Automotive Engineering, in cooperation with the Laboratory of Hydraulic Drives & Vibroacoustics of Machines at the Wroclaw University of Technology. The broader study has so far allowed us to develop an authoritative method of identifying the type of engine damage using gametree structures. The present works assess the possibility of using multi-valued logic trees.

  4. What controls stemflow? A LiDAR-based investigation of individual tree canopy structure, neighborhood conditions, and meteorological factors

    Science.gov (United States)

    Yankine, S. A.; Van Stan, J. T., II; Mesta, D. C.; Côté, J. F.; Hildebrandt, A.; Friesen, J.; Maldonado, G.

    2017-12-01

    Stemflow is a pointed hydrologic flux at the base of tree stems that has been linked to a host of biogeochemical processes in vegetated landscapes. Much work has been done to examine controls over stemflow water yield, finding three major factors: individual tree canopy structure, meteorological variables, and neighborhood conditions. However, the authors are unaware of any study to directly quantify all factors using a combination of terrestrial LiDAR and micrometeorological monitoring methods. This study directly quantifies individual Pinus palustris tree canopy characteristics (trunk volume and angle, branch volume and angle from 1st-to-3rd order, bark roughness, and height), 10-m radius neighborhood properties (number of trees, mean diameter and height, mean distance from study tree, and canopy overlap), and above-canopy storm conditions (magnitude, intensity, mean/max wind speed, and vapor pressure deficit) directly at the site. Stemflow production was 1% of rainfall, ranging from 0.3-59 L per storm from individual trees. Preliminary findings from storms (5-176 mm in magnitude) indicate that all individual tree characteristics, besides bark roughness, have little influence on stemflow generation. Bark roughness altered stemflow generation by affecting trunk water storage (0.1-0.7 mm) and wet trunk evaporation rates (0.005-0.03 mm/h). The strongest influence over stemflow generation from individual trees was the interaction between neighborhood characteristics and meteorological conditions (primarily rainfall amount and, secondarily, rainfall intensity).

  5. Synthesis of Fault-Tolerant Embedded Systems

    DEFF Research Database (Denmark)

    Eles, Petru; Izosimov, Viacheslav; Pop, Paul

    2008-01-01

    This work addresses the issue of design optimization for fault- tolerant hard real-time systems. In particular, our focus is on the handling of transient faults using both checkpointing with rollback recovery and active replication. Fault tolerant schedules are generated based on a conditional...... process graph representation. The formulated system synthesis approaches decide the assignment of fault-tolerance policies to processes, the optimal placement of checkpoints and the mapping of processes to processors, such that multiple transient faults are tolerated, transparency requirements...

  6. Fault Current Distribution and Pole Earth Potential Rise (EPR) Under Substation Fault

    Science.gov (United States)

    Nnassereddine, M.; Rizk, J.; Hellany, A.; Nagrial, M.

    2013-09-01

    New high-voltage (HV) substations are fed by transmission lines. The position of these lines necessitates earthing design to ensure safety compliance of the system. Conductive structures such as steel or concrete poles are widely used in HV transmission mains. The earth potential rise (EPR) generated by a fault at the substation could result in an unsafe condition. This article discusses EPR based on substation fault. The pole EPR assessment under substation fault is assessed with and without mutual impedance consideration. Split factor determination with and without the mutual impedance of the line is also discussed. Furthermore, a simplified formula to compute the pole grid current under substation fault is included. Also, it includes the introduction of the n factor which determines the number of poles that required earthing assessments under substation fault. A case study is shown.

  7. High-Intensity Radiated Field Fault-Injection Experiment for a Fault-Tolerant Distributed Communication System

    Science.gov (United States)

    Yates, Amy M.; Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Gonzalez, Oscar R.; Gray, W. Steven

    2010-01-01

    Safety-critical distributed flight control systems require robustness in the presence of faults. In general, these systems consist of a number of input/output (I/O) and computation nodes interacting through a fault-tolerant data communication system. The communication system transfers sensor data and control commands and can handle most faults under typical operating conditions. However, the performance of the closed-loop system can be adversely affected as a result of operating in harsh environments. In particular, High-Intensity Radiated Field (HIRF) environments have the potential to cause random fault manifestations in individual avionic components and to generate simultaneous system-wide communication faults that overwhelm existing fault management mechanisms. This paper presents the design of an experiment conducted at the NASA Langley Research Center's HIRF Laboratory to statistically characterize the faults that a HIRF environment can trigger on a single node of a distributed flight control system.

  8. Descriptive statistics of tree crown condition in the Southern United States and impacts on data analysis and interpretation

    Science.gov (United States)

    KaDonna C. Randolph

    2006-01-01

    The U.S. Department of Agriculture Forest Service, Forest Inventory and Analysis Program (FIA) utilizes visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes and discusses distributions of three FIA crown condition indicators (crown density, crown dieback, and foliage transparency) for trees in the Southern...

  9. Variable coupling between sap-flow and transpiration in pine trees under drought conditions

    Science.gov (United States)

    Preisler, Yakir; Tatarinov, Fyodor; Rohatyn, Shani; Rotenberg, Eyal; Grunzweig, Jose M.; Yakir, Dan

    2016-04-01

    Changes in diurnal patterns in water transport and physiological activities in response to changes in environmental conditions are important adjustments of trees to drought. The rate of sap flow (SF) in trees is expected to be in agreement with the rate of tree-scale transpiration (T) and provides a powerful measure of water transport in the soil-plant-atmosphere system. The aim of this five-years study was to investigate the temporal links between SF and T in Pinus halepensis exposed to extreme seasonal drought in the Yatir forest in Israel. We continuously measured SF (20 trees), the daily variations in stem diameter (ΔDBH, determined with high precision dendrometers; 8 trees), and ecosystem evapotranspiration (ET; eddy covariance), which were complemented with short-term campaigns of leaf-scale measurements of H2O and CO2 gas exchange, water potentials, and hydraulic conductivity. During the rainy season, tree SF was well synchronized with ecosystem ET, reaching maximum rates during midday in all trees. However, during the dry season, the daily SF trends greatly varied among trees, allowing a classification of trees into three classes: 1) Trees that remain with SF maximum at midday, 2) trees that advanced their SF peak to early morning, and 3) trees that delayed their SF peak to late afternoon hours. This classification remained valid for the entire study period (2010-2015), and strongly correlated with tree height and DBH, and to a lower degree with crown size and competition index. In the dry season, class 3 trees (large) tended to delay the timing of SF maximum to the afternoon, and to advance their maximum diurnal DBH to early morning, while class 2 trees (smaller) advanced their SF maximum to early morning and had maximum daily DBH during midday and afternoon. Leaf-scale transpiration (T), measurements showed a typical morning peak in all trees, irrespective of classification, and a secondary peak in the afternoon in large trees only. Water potential and

  10. Stand conditions and tree characteristics affect quality of longleaf pine for red-cockaded woodpecker cavity trees

    Science.gov (United States)

    W.G. Ross; D.L. Kulhavy; R.N. Conner

    1997-01-01

    We measured resin flow of longleaf (Pinus palustris Mill.) pines in red-cockaded woodpecker (Picoides borealis Vieillot) clusters in the Angelina National Forest in Texas, and the Apalachicola National Forest in Florida. Sample trees were categorized as active cavity trees, inactive cavity trees and control trees. Sample trees were further...

  11. An integrated model for reliability estimation of digital nuclear protection system based on fault tree and software control flow methodologies

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Seong, Poong Hyun

    2000-01-01

    In the nuclear industry, the difficulty of proving the reliabilities of digital systems prohibits the widespread use of digital systems in various nuclear application such as plant protection system. Even though there exist a few models which are used to estimate the reliabilities of digital systems, we develop a new integrated model which is more realistic than the existing models. We divide the process of estimating the reliability of a digital system into two phases, a high-level phase and a low-level phase, and the boundary of two phases is the reliabilities of subsystems. We apply software control flow method to the low-level phase and fault tree analysis to the high-level phase. The application of the model to Dynamic Safety System(DDS) shows that the estimated reliability of the system is quite reasonable and realistic

  12. An integrated model for reliability estimation of digital nuclear protection system based on fault tree and software control flow methodologies

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Seong, Poong Hyun

    2000-01-01

    In nuclear industry, the difficulty of proving the reliabilities of digital systems prohibits the widespread use of digital systems in various nuclear application such as plant protection system. Even though there exist a few models which are used to estimate the reliabilities of digital systems, we develop a new integrated model which is more realistic than the existing models. We divide the process of estimating the reliability of a digital system into two phases, a high-level phase and a low-level phase, and the boundary of two phases is the reliabilities of subsystems. We apply software control flow method to the low-level phase and fault tree analysis to the high-level phase. The application of the model of dynamic safety system (DSS) shows that the estimated reliability of the system is quite reasonable and realistic. (author)

  13. Active fault diagnosis in closed-loop uncertain systems

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    2006-01-01

    Fault diagnosis of parametric faults in closed-loop uncertain systems by using an auxiliary input vector is considered in this paper, i.e. active fault diagnosis (AFD). The active fault diagnosis is based directly on the socalled fault signature matrix, related to the YJBK (Youla, Jabr, Bongiorno...... and Kucera) parameterization. Conditions are given for exact detection and isolation of parametric faults in closed-loop uncertain systems....

  14. Temperature profile in apricot tree canopies under the soil and climate conditions of the Romanian Black Sea Coast

    Science.gov (United States)

    Paltineanu, Cristian; Septar, Leinar; Chitu, Emil

    2016-03-01

    The paper describes the temperature profiles determined by thermal imagery in apricot tree canopies under the semi-arid conditions of the Black Sea Coast in a chernozem of Dobrogea Region, Romania. The study analyzes the thermal vertical profile of apricot orchards for three representative cultivars during summertime. Measurements were done when the soil water content (SWC) was at field capacity (FC) within the rooting depth, after intense sprinkler irrigation applications. Canopy temperature was measured during clear sky days at three heights for both sides of the apricot trees, sunlit (south), and shaded (north). For the SWC studied, i.e., FC, canopy height did not induce a significant difference between the temperature of apricot tree leaves (Tc) and the ambient air temperature (Ta) within the entire vertical tree profile, and temperature measurements by thermal imagery can therefore be taken at any height on the tree crown leaves. Differences between sunlit and shaded sides of the canopy were significant. Because of these differences for Tc-Ta among the apricot tree cultivars studied, lower base lines (LBLs) should be determined for each cultivar separately. The use of thermal imagery technique under the conditions of semi-arid coastal areas with low range of vapor pressure deficit could be useful in irrigation scheduling of apricot trees. The paper discusses the implications of the data obtained in the experiment under the conditions of the coastal area of the Black Sea, Romania, and neighboring countries with similar climate, such as Bulgaria and Turkey.

  15. Condition monitoring of face milling tool using K-star algorithm and histogram features of vibration signal

    Directory of Open Access Journals (Sweden)

    C.K. Madhusudana

    2016-09-01

    Full Text Available This paper deals with the fault diagnosis of the face milling tool based on machine learning approach using histogram features and K-star algorithm technique. Vibration signals of the milling tool under healthy and different fault conditions are acquired during machining of steel alloy 42CrMo4. Histogram features are extracted from the acquired signals. The decision tree is used to select the salient features out of all the extracted features and these selected features are used as an input to the classifier. K-star algorithm is used as a classifier and the output of the model is utilised to study and classify the different conditions of the face milling tool. Based on the experimental results, K-star algorithm is provided a better classification accuracy in the range from 94% to 96% with histogram features and is acceptable for fault diagnosis.

  16. Active Fault-Tolerant Control for Wind Turbine with Simultaneous Actuator and Sensor Faults

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2017-01-01

    Full Text Available The purpose of this paper is to show a novel fault-tolerant tracking control (FTC strategy with robust fault estimation and compensating for simultaneous actuator sensor faults. Based on the framework of fault-tolerant control, developing an FTC design method for wind turbines is a challenge and, thus, they can tolerate simultaneous pitch actuator and pitch sensor faults having bounded first time derivatives. The paper’s key contribution is proposing a descriptor sliding mode method, in which for establishing a novel augmented descriptor system, with which we can estimate the state of system and reconstruct fault by designing descriptor sliding mode observer, the paper introduces an auxiliary descriptor state vector composed by a system state vector, actuator fault vector, and sensor fault vector. By the optimized method of LMI, the conditions for stability that estimated error dynamics are set up to promote the determination of the parameters designed. With this estimation, and designing a fault-tolerant controller, the system’s stability can be maintained. The effectiveness of the design strategy is verified by implementing the controller in the National Renewable Energy Laboratory’s 5-MW nonlinear, high-fidelity wind turbine model (FAST and simulating it in MATLAB/Simulink.

  17. Smart intimation and location of faults in distribution system

    Science.gov (United States)

    Hari Krishna, K.; Srinivasa Rao, B.

    2018-04-01

    Location of faults in the distribution system is one of the most complicated problems that we are facing today. Identification of fault location and severity of fault within a short time is required to provide continuous power supply but fault identification and information transfer to the operator is the biggest challenge in the distribution network. This paper proposes a fault location method in the distribution system based on Arduino nano and GSM module with flame sensor. The main idea is to locate the fault in the distribution transformer by sensing the arc coming out from the fuse element. The biggest challenge in the distribution network is to identify the location and the severity of faults under different conditions. Well operated transmission and distribution systems will play a key role for uninterrupted power supply. Whenever fault occurs in the distribution system the time taken to locate and eliminate the fault has to be reduced. The proposed design was achieved with flame sensor and GSM module. Under faulty condition, the system will automatically send an alert message to the operator in the distribution system, about the abnormal conditions near the transformer, site code and its exact location for possible power restoration.

  18. Solar system fault detection

    Science.gov (United States)

    Farrington, R.B.; Pruett, J.C. Jr.

    1984-05-14

    A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

  19. Method and system for environmentally adaptive fault tolerant computing

    Science.gov (United States)

    Copenhaver, Jason L. (Inventor); Jeremy, Ramos (Inventor); Wolfe, Jeffrey M. (Inventor); Brenner, Dean (Inventor)

    2010-01-01

    A method and system for adapting fault tolerant computing. The method includes the steps of measuring an environmental condition representative of an environment. An on-board processing system's sensitivity to the measured environmental condition is measured. It is determined whether to reconfigure a fault tolerance of the on-board processing system based in part on the measured environmental condition. The fault tolerance of the on-board processing system may be reconfigured based in part on the measured environmental condition.

  20. Exact, almost and delayed fault detection

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Saberi, Ali; Stoorvogel, Anton A.

    1999-01-01

    Considers the problem of fault detection and isolation while using zero or almost zero threshold. A number of different fault detection and isolation problems using exact or almost exact disturbance decoupling are formulated. Solvability conditions are given for the formulated design problems....... The l-step delayed fault detection problem is also considered for discrete-time systems....

  1. Data to support "Boosted Regression Tree Models to Explain Watershed Nutrient Concentrations & Biological Condition"

    Data.gov (United States)

    U.S. Environmental Protection Agency — Spreadsheets are included here to support the manuscript "Boosted Regression Tree Models to Explain Watershed Nutrient Concentrations and Biological Condition". This...

  2. Exemplifying whole-plant ozone uptake in adult forest trees of contrasting species and site conditions

    International Nuclear Information System (INIS)

    Nunn, Angela J.; Wieser, Gerhard; Metzger, Ursula; Loew, Markus; Wipfler, Philip; Haeberle, Karl-Heinz; Matyssek, Rainer

    2007-01-01

    Whole-tree O 3 uptake was exemplified for Picea abies, Fagus sylvatica and Larix decidua in stands at high and low altitude and contrasting water availability through sap flow measurement in tree trunks, intrinsically accounting for drought and boundary layer effects on O 3 flux. O 3 uptake of evergreen spruce per unit foliage area was enhanced by 100% at high relative to low elevation, whereas deciduous beech and larch showed similar uptake regardless of altitude. The responsiveness of the canopy conductance to water vapor and, as a consequence, O 3 uptake to soil moisture and air humidity did not differ between species. Unifying findings at the whole-tree level will promote cause-effect based O 3 risk assessment and modeling. - Sap flow-based assessment of whole-tree O 3 uptake reflects similar responsiveness of canopy conductance and O 3 uptake across contrasting tree species and site conditions

  3. Tree-growth analyses to estimate tree species' drought tolerance

    NARCIS (Netherlands)

    Eilmann, B.; Rigling, A.

    2012-01-01

    Climate change is challenging forestry management and practices. Among other things, tree species with the ability to cope with more extreme climate conditions have to be identified. However, while environmental factors may severely limit tree growth or even cause tree death, assessing a tree

  4. Safety assessment of radioactive waste disposal into geological formations; a preliminary application of fault tree analysis to salt deposits

    International Nuclear Information System (INIS)

    Bertozzi, B.; D'Alessandro, M.; Girardi, F.; Vanossi, M.

    1978-01-01

    The methodology of the fault tree analysis (FTA) has been widely used at the Joint Research Centre of Ispra in nuclear reactor safety studies. The aim of the present work consisted in studying the applicability of this methodology to geological repositories of radioactive wastes, including criteria and approaches for the quantification of probalities of primary events. The present work has just an illustrative purpose. Two ideal cases of saline formations, I.E. a bedded salt and a diapir were chosen as potential disposal sites for radioactive waste. On the basis of arbitrarily assumed hydrogeological features of the salt formations and their surrounding environment, possible phenomena capable of causing the waste to be released from each formation have been discussed and gathered following the logical schemes of the FTA. The assessment of probability values for release events due to natural causes as well as to human actions, over different time periods, up to one million years, has been discussed

  5. An Intelligent Gear Fault Diagnosis Methodology Using a Complex Wavelet Enhanced Convolutional Neural Network

    Science.gov (United States)

    Sun, Weifang; Yao, Bin; Zeng, Nianyin; He, Yuchao; Cao, Xincheng; He, Wangpeng

    2017-01-01

    As a typical example of large and complex mechanical systems, rotating machinery is prone to diversified sorts of mechanical faults. Among these faults, one of the prominent causes of malfunction is generated in gear transmission chains. Although they can be collected via vibration signals, the fault signatures are always submerged in overwhelming interfering contents. Therefore, identifying the critical fault’s characteristic signal is far from an easy task. In order to improve the recognition accuracy of a fault’s characteristic signal, a novel intelligent fault diagnosis method is presented. In this method, a dual-tree complex wavelet transform (DTCWT) is employed to acquire the multiscale signal’s features. In addition, a convolutional neural network (CNN) approach is utilized to automatically recognise a fault feature from the multiscale signal features. The experiment results of the recognition for gear faults show the feasibility and effectiveness of the proposed method, especially in the gear’s weak fault features. PMID:28773148

  6. Data-driven simultaneous fault diagnosis for solid oxide fuel cell system using multi-label pattern identification

    Science.gov (United States)

    Li, Shuanghong; Cao, Hongliang; Yang, Yupu

    2018-02-01

    Fault diagnosis is a key process for the reliability and safety of solid oxide fuel cell (SOFC) systems. However, it is difficult to rapidly and accurately identify faults for complicated SOFC systems, especially when simultaneous faults appear. In this research, a data-driven Multi-Label (ML) pattern identification approach is proposed to address the simultaneous fault diagnosis of SOFC systems. The framework of the simultaneous-fault diagnosis primarily includes two components: feature extraction and ML-SVM classifier. The simultaneous-fault diagnosis approach can be trained to diagnose simultaneous SOFC faults, such as fuel leakage, air leakage in different positions in the SOFC system, by just using simple training data sets consisting only single fault and not demanding simultaneous faults data. The experimental result shows the proposed framework can diagnose the simultaneous SOFC system faults with high accuracy requiring small number training data and low computational burden. In addition, Fault Inference Tree Analysis (FITA) is employed to identify the correlations among possible faults and their corresponding symptoms at the system component level.

  7. A hybrid approach to fault diagnosis of roller bearings under variable speed conditions

    Science.gov (United States)

    Wang, Yanxue; Yang, Lin; Xiang, Jiawei; Yang, Jianwei; He, Shuilong

    2017-12-01

    Rolling element bearings are one of the main elements in rotating machines, whose failure may lead to a fatal breakdown and significant economic losses. Conventional vibration-based diagnostic methods are based on the stationary assumption, thus they are not applicable to the diagnosis of bearings working under varying speeds. This constraint limits the bearing diagnosis to the industrial application significantly. A hybrid approach to fault diagnosis of roller bearings under variable speed conditions is proposed in this work, based on computed order tracking (COT) and variational mode decomposition (VMD)-based time frequency representation (VTFR). COT is utilized to resample the non-stationary vibration signal in the angular domain, while VMD is used to decompose the resampled signal into a number of band-limited intrinsic mode functions (BLIMFs). A VTFR is then constructed based on the estimated instantaneous frequency and instantaneous amplitude of each BLIMF. Moreover, the Gini index and time-frequency kurtosis are both proposed to quantitatively measure the sparsity and concentration measurement of time-frequency representation, respectively. The effectiveness of the VTFR for extracting nonlinear components has been verified by a bat signal. Results of this numerical simulation also show the sparsity and concentration of the VTFR are better than those of short-time Fourier transform, continuous wavelet transform, Hilbert-Huang transform and Wigner-Ville distribution techniques. Several experimental results have further demonstrated that the proposed method can well detect bearing faults under variable speed conditions.

  8. What is Fault Tolerant Control

    DEFF Research Database (Denmark)

    Blanke, Mogens; Frei, C. W.; Kraus, K.

    2000-01-01

    Faults in automated processes will often cause undesired reactions and shut-down of a controlled plant, and the consequences could be damage to the plant, to personnel or the environment. Fault-tolerant control is the synonym for a set of recent techniques that were developed to increase plant...... availability and reduce the risk of safety hazards. Its aim is to prevent that simple faults develop into serious failure. Fault-tolerant control merges several disciplines to achieve this goal, including on-line fault diagnosis, automatic condition assessment and calculation of remedial actions when a fault...... is detected. The envelope of the possible remedial actions is wide. This paper introduces tools to analyze and explore structure and other fundamental properties of an automated system such that any redundancy in the process can be fully utilized to enhance safety and a availability....

  9. Analysis of Back-to-Back MMC for Medium Voltage Applications under Faulted Condition

    DEFF Research Database (Denmark)

    Bose, Anurag; Martins, Joäo Pedro Rodrigues; Chaudhary, Sanjay K.

    2017-01-01

    This paper analyzes a 10MW medium voltage Back-to-Back (BTB) Modular Multilevel Converter (MMC) without a DC-Link capacitor with halfbridge submodules. It focusses on the system behavior under single-line-to-ground (SLG) fault when there is no capacitor on the DC-Link.The fault current is compute...... to prevent DC overvoltages in the sub-modules during faults....

  10. Can phenological models predict tree phenology accurately under climate change conditions?

    Science.gov (United States)

    Chuine, Isabelle; Bonhomme, Marc; Legave, Jean Michel; García de Cortázar-Atauri, Inaki; Charrier, Guillaume; Lacointe, André; Améglio, Thierry

    2014-05-01

    The onset of the growing season of trees has been globally earlier by 2.3 days/decade during the last 50 years because of global warming and this trend is predicted to continue according to climate forecast. The effect of temperature on plant phenology is however not linear because temperature has a dual effect on bud development. On one hand, low temperatures are necessary to break bud dormancy, and on the other hand higher temperatures are necessary to promote bud cells growth afterwards. Increasing phenological changes in temperate woody species have strong impacts on forest trees distribution and productivity, as well as crops cultivation areas. Accurate predictions of trees phenology are therefore a prerequisite to understand and foresee the impacts of climate change on forests and agrosystems. Different process-based models have been developed in the last two decades to predict the date of budburst or flowering of woody species. They are two main families: (1) one-phase models which consider only the ecodormancy phase and make the assumption that endodormancy is always broken before adequate climatic conditions for cell growth occur; and (2) two-phase models which consider both the endodormancy and ecodormancy phases and predict a date of dormancy break which varies from year to year. So far, one-phase models have been able to predict accurately tree bud break and flowering under historical climate. However, because they do not consider what happens prior to ecodormancy, and especially the possible negative effect of winter temperature warming on dormancy break, it seems unlikely that they can provide accurate predictions in future climate conditions. It is indeed well known that a lack of low temperature results in abnormal pattern of bud break and development in temperate fruit trees. An accurate modelling of the dormancy break date has thus become a major issue in phenology modelling. Two-phases phenological models predict that global warming should delay

  11. Obesity as a risk factor for developing functional limitation among older adults: A conditional inference tree analysis

    Science.gov (United States)

    Objective: To examine the risk factors of developing functional decline and make probabilistic predictions by using a tree-based method that allows higher order polynomials and interactions of the risk factors. Methods: The conditional inference tree analysis, a data mining approach, was used to con...

  12. Overview of condition monitoring and operation control of electric power conversion systems in direct-drive wind turbines under faults

    Science.gov (United States)

    Huang, Shoudao; Wu, Xuan; Liu, Xiao; Gao, Jian; He, Yunze

    2017-09-01

    Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs.

  13. LCD denoise and the vector mutual information method in the application of the gear fault diagnosis under different working conditions

    Science.gov (United States)

    Xiangfeng, Zhang; Hong, Jiang

    2018-03-01

    In this paper, the full vector LCD method is proposed to solve the misjudgment problem caused by the change of the working condition. First, the signal from different working condition is decomposed by LCD, to obtain the Intrinsic Scale Component (ISC)whose instantaneous frequency with physical significance. Then, calculate of the cross correlation coefficient between ISC and the original signal, signal denoising based on the principle of mutual information minimum. At last, calculate the sum of absolute Vector mutual information of the sample under different working condition and the denoised ISC as the characteristics to classify by use of Support vector machine (SVM). The wind turbines vibration platform gear box experiment proves that this method can identify fault characteristics under different working conditions. The advantage of this method is that it reduce dependence of man’s subjective experience, identify fault directly from the original data of vibration signal. It will has high engineering value.

  14. Review of fault diagnosis and fault-tolerant control for modular multilevel converter of HVDC

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    This review focuses on faults in Modular Multilevel Converter (MMC) for use in high voltage direct current (HVDC) systems by analyzing the vulnerable spots and failure mechanism from device to system and illustrating the control & protection methods under failure condition. At the beginning......, several typical topologies of MMC-HVDC systems are presented. Then fault types such as capacitor voltage unbalance, unbalance between upper and lower arm voltage are analyzed and the corresponding fault detection and diagnosis approaches are explained. In addition, more attention is dedicated to control...

  15. Broken Bar Fault Detection in IM Operating Under No-Load Condition

    Directory of Open Access Journals (Sweden)

    RELJIC, D.

    2016-11-01

    Full Text Available This paper presents a novel method for broken rotor bar detection in a squirrel-cage induction motor (IM. The proposed method applies a single-phase AC voltage as a test signal on motor terminals, resulting in a stator backward-rotating magnetic field. The field ultimately causes additional current components in the stator windings whose magnitudes depend on the broken bar fault severity, even if the motor is unloaded. This allows robust broken bar fault detection based only on standard motor current signature analysis (MCSA technique. The proposed fault detection method is at first verified via simulations, using an IM model based on finite element analysis (FEA and multiple coupled circuit approach (MCCA. The subsequent experimental investigations have shown good agreement with both theoretical predictions and simulation results.

  16. Probabilistic Risk Analysis and Fault Trees as Tools in Improving the Delineation of Wellhead Protection Areas: An Initial Discussion

    Science.gov (United States)

    Rodak, C. M.; Silliman, S. E.

    2010-12-01

    Delineation of a wellhead protection area (WHPA) is a critical component of managing / protecting the aquifer(s) supplying potable water to a public water-supply well. While a number of previous authors have addressed questions related to uncertainties in advective capture zones, methods for assessing WHPAs in the presence of uncertainty in the chemistry of groundwater contaminants, the relationship between land-use and contaminant sources, and the impact on health risk within the receiving population are more limited. Probabilistic risk analysis (PRA) combined with fault trees (FT) addresses this latter challenge by providing a structure whereby four key WHPA issues may be addressed: (i) uncertainty in land-use practices and chemical release, (ii) uncertainty in groundwater flow, (iii) variability in natural attenuation properties (and/or remediation) of the contaminants, and (iv) estimated health risk from contaminant arrival at a well. The potential utility of PRA-FT in this application is considered through a simplified case study involving management decisions related both to regional land use planning and local land-use zoning regulation. An application-specific fault tree is constructed to visualize and identify the events required for health risk failure at the well and a Monte Carlo approach is used to create multiple realizations of groundwater flow and chemical transport to a well in a model of a simple, unconfined aquifer. Model parameters allowed to vary during this simplified case study include hydraulic conductivity, probability of a chemical spill (related to land use variation in space), and natural attenuation through variation in rate of decay of the contaminant. Numerical results are interpreted in association with multiple land-use management scenarios as well as multiple cancer risk assumptions regarding the contaminant arriving at the well. This case study shows significant variability of health risk at the well, however general trends were

  17. Fault isolability with different forms of the faults–symptoms relation

    Directory of Open Access Journals (Sweden)

    Kóscielny Jan Maciej

    2016-12-01

    Full Text Available The definitions and conditions for fault isolability of single faults for various forms of the diagnostic relation are reviewed. Fault isolability and unisolability on the basis of a binary diagnostic matrix are analyzed. Definitions for conditional and unconditional isolability and unisolability on the basis of a fault information system (FIS, symptom sequences and directional residuals are formulated. General definitions for conditional and unconditional isolability and unisolability in the cases of simultaneous evaluation of diagnostic signal values and a sequence of symptoms are provided. A comprehensive example is discussed.

  18. Human reliability analysis using event trees

    International Nuclear Information System (INIS)

    Heslinga, G.

    1983-01-01

    The shut-down procedure of a technologically complex installation as a nuclear power plant consists of a lot of human actions, some of which have to be performed several times. The procedure is regarded as a chain of modules of specific actions, some of which are analyzed separately. The analysis is carried out by making a Human Reliability Analysis event tree (HRA event tree) of each action, breaking down each action into small elementary steps. The application of event trees in human reliability analysis implies more difficulties than in the case of technical systems where event trees were mainly used until now. The most important reason is that the operator is able to recover a wrong performance; memory influences play a significant role. In this study these difficulties are dealt with theoretically. The following conclusions can be drawn: (1) in principle event trees may be used in human reliability analysis; (2) although in practice the operator will recover his fault partly, theoretically this can be described as starting the whole event tree again; (3) compact formulas have been derived, by which the probability of reaching a specific failure consequence on passing through the HRA event tree after several times of recovery is to be calculated. (orig.)

  19. Rainforest air-conditioning: the moderating influence of epiphytes on the microclimate in tropical tree crowns

    Science.gov (United States)

    Stuntz, Sabine; Simon, Ulrich; Zotz, Gerhard

    2002-05-01

    Epiphytes are often assumed to influence the microclimatic conditions of the tree crowns that they inhabit. In order to quantify this notion, we measured the parameters "temperature" (of the substrate surface and the boundary layer of air above it), "evaporative drying rate" and "evapotranspiration" at various locations within tree crowns with differing epiphyte assemblages. The host tree species was Annona glabra, which was either populated by one of three epiphyte species ( Dimerandra emarginata, Tillandsia fasciculata, or Vriesea sanguinolenta) or was epiphyte-free. We found that during the hottest and driest time of day, microsites in the immediate proximity of epiphytes had significantly lower temperatures than epiphyte-bare locations within the same tree crown, even though the latter were also shaded by host tree foliage or branches. Moreover, water loss through evaporative drying at microsites adjacent to epiphytes was almost 20% lower than at exposed microsites. We also found that, over the course of several weeks, the evapotranspiration in tree crowns bearing epiphytes was significantly lower than in trees without epiphytes. Although the influence of epiphytes on temperature extremes and evaporation rates is relatively subtle, their mitigating effect could be of importance for small animals like arthropods inhabiting an environment as harsh and extreme as the tropical forest canopy.

  20. A novel KFCM based fault diagnosis method for unknown faults in satellite reaction wheels.

    Science.gov (United States)

    Hu, Di; Sarosh, Ali; Dong, Yun-Feng

    2012-03-01

    Reaction wheels are one of the most critical components of the satellite attitude control system, therefore correct diagnosis of their faults is quintessential for efficient operation of these spacecraft. The known faults in any of the subsystems are often diagnosed by supervised learning algorithms, however, this method fails to work correctly when a new or unknown fault occurs. In such cases an unsupervised learning algorithm becomes essential for obtaining the correct diagnosis. Kernel Fuzzy C-Means (KFCM) is one of the unsupervised algorithms, although it has its own limitations; however in this paper a novel method has been proposed for conditioning of KFCM method (C-KFCM) so that it can be effectively used for fault diagnosis of both known and unknown faults as in satellite reaction wheels. The C-KFCM approach involves determination of exact class centers from the data of known faults, in this way discrete number of fault classes are determined at the start. Similarity parameters are derived and determined for each of the fault data point. Thereafter depending on the similarity threshold each data point is issued with a class label. The high similarity points fall into one of the 'known-fault' classes while the low similarity points are labeled as 'unknown-faults'. Simulation results show that as compared to the supervised algorithm such as neural network, the C-KFCM method can effectively cluster historical fault data (as in reaction wheels) and diagnose the faults to an accuracy of more than 91%. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Locating hardware faults in a parallel computer

    Science.gov (United States)

    Archer, Charles J.; Megerian, Mark G.; Ratterman, Joseph D.; Smith, Brian E.

    2010-04-13

    Locating hardware faults in a parallel computer, including defining within a tree network of the parallel computer two or more sets of non-overlapping test levels of compute nodes of the network that together include all the data communications links of the network, each non-overlapping test level comprising two or more adjacent tiers of the tree; defining test cells within each non-overlapping test level, each test cell comprising a subtree of the tree including a subtree root compute node and all descendant compute nodes of the subtree root compute node within a non-overlapping test level; performing, separately on each set of non-overlapping test levels, an uplink test on all test cells in a set of non-overlapping test levels; and performing, separately from the uplink tests and separately on each set of non-overlapping test levels, a downlink test on all test cells in a set of non-overlapping test levels.

  2. Diagnosis of constant faults in read-once contact networks over finite bases

    KAUST Repository

    Busbait, Monther I.; Chikalov, Igor; Hussain, Shahid; Moshkov, Mikhail

    2015-01-01

    We study the depth of decision trees for diagnosis of constant 0 and 1 faults in read-once contact networks over finite bases containing only indecomposable networks. For each basis, we obtain a linear upper bound on the minimum depth of decision trees depending on the number of edges in the networks. For bases containing networks with at most 10 edges we find coefficients for linear bounds which are close to sharp. © 2014 Elsevier B.V. All rights reserved.

  3. Diagnosis of constant faults in read-once contact networks over finite bases

    KAUST Repository

    Busbait, Monther I.

    2015-03-01

    We study the depth of decision trees for diagnosis of constant 0 and 1 faults in read-once contact networks over finite bases containing only indecomposable networks. For each basis, we obtain a linear upper bound on the minimum depth of decision trees depending on the number of edges in the networks. For bases containing networks with at most 10 edges we find coefficients for linear bounds which are close to sharp. © 2014 Elsevier B.V. All rights reserved.

  4. Stable carbon isotopic composition of tree rings from a pine tree from Augustów Wilderness, Poland, as a temperature and local environment conditions indicator.

    Science.gov (United States)

    Pawelczyk, Slawomira; Pazdur, Anna; Halas, Stanislaw

    2004-06-01

    Tree rings can be used as archives of climatic and environmental data with annual resolution. Tree rings widths, maximum late wood density and other parameters as stable composition in tree rings can be used for the reconstruction of past climatic and environmental changes. Stable carbon isotope ratios in tree rings may provide valuable information on past climatic conditions. 13C/12C ratios of plant organic matter can reflect corresponding 13C/12C ratio of atmospheric CO2 during formation of the rings. Investigations of isotopic carbon composition in tree rings from in the ecologically clean the Augustów Wilderness region in the north-eastern part of Poland (22 degrees 58'E, 53 degrees 51'N) (nowadays a sanctuary) were undertaken. Series of delta13C in alpha-cellulose and in wholewood were acquired. Those measurements constituted a part of more complex investigations of carbon isotope composition in tree rings including the measurements of radiocarbon concentration and tree ring widths. This article presents preliminary results. It is argued that contrary to the tree ring widths and delta13C in wholewood that do not reveal significant correlation with temperature, the variation of delta13C in the latewood alpha-cellulose is correlated with combined July and August temperatures. Copyright 2004 Taylor and Francis Ltd.

  5. A review on data-driven fault severity assessment in rolling bearings

    Science.gov (United States)

    Cerrada, Mariela; Sánchez, René-Vinicio; Li, Chuan; Pacheco, Fannia; Cabrera, Diego; Valente de Oliveira, José; Vásquez, Rafael E.

    2018-01-01

    Health condition monitoring of rotating machinery is a crucial task to guarantee reliability in industrial processes. In particular, bearings are mechanical components used in most rotating devices and they represent the main source of faults in such equipments; reason for which research activities on detecting and diagnosing their faults have increased. Fault detection aims at identifying whether the device is or not in a fault condition, and diagnosis is commonly oriented towards identifying the fault mode of the device, after detection. An important step after fault detection and diagnosis is the analysis of the magnitude or the degradation level of the fault, because this represents a support to the decision-making process in condition based-maintenance. However, no extensive works are devoted to analyse this problem, or some works tackle it from the fault diagnosis point of view. In a rough manner, fault severity is associated with the magnitude of the fault. In bearings, fault severity can be related to the physical size of fault or a general degradation of the component. Due to literature regarding the severity assessment of bearing damages is limited, this paper aims at discussing the recent methods and techniques used to achieve the fault severity evaluation in the main components of the rolling bearings, such as inner race, outer race, and ball. The review is mainly focused on data-driven approaches such as signal processing for extracting the proper fault signatures associated with the damage degradation, and learning approaches that are used to identify degradation patterns with regards to health conditions. Finally, new challenges are highlighted in order to develop new contributions in this field.

  6. SVD and Hankel matrix based de-noising approach for ball bearing fault detection and its assessment using artificial faults

    Science.gov (United States)

    Golafshan, Reza; Yuce Sanliturk, Kenan

    2016-03-01

    Ball bearings remain one of the most crucial components in industrial machines and due to their critical role, it is of great importance to monitor their conditions under operation. However, due to the background noise in acquired signals, it is not always possible to identify probable faults. This incapability in identifying the faults makes the de-noising process one of the most essential steps in the field of Condition Monitoring (CM) and fault detection. In the present study, Singular Value Decomposition (SVD) and Hankel matrix based de-noising process is successfully applied to the ball bearing time domain vibration signals as well as to their spectrums for the elimination of the background noise and the improvement the reliability of the fault detection process. The test cases conducted using experimental as well as the simulated vibration signals demonstrate the effectiveness of the proposed de-noising approach for the ball bearing fault detection.

  7. Development of Fault Models for Hybrid Fault Detection and Diagnostics Algorithm: October 1, 2014 -- May 5, 2015

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Howard [Purdue Univ., West Lafayette, IN (United States); Braun, James E. [Purdue Univ., West Lafayette, IN (United States)

    2015-12-31

    This report describes models of building faults created for OpenStudio to support the ongoing development of fault detection and diagnostic (FDD) algorithms at the National Renewable Energy Laboratory. Building faults are operating abnormalities that degrade building performance, such as using more energy than normal operation, failing to maintain building temperatures according to the thermostat set points, etc. Models of building faults in OpenStudio can be used to estimate fault impacts on building performance and to develop and evaluate FDD algorithms. The aim of the project is to develop fault models of typical heating, ventilating and air conditioning (HVAC) equipment in the United States, and the fault models in this report are grouped as control faults, sensor faults, packaged and split air conditioner faults, water-cooled chiller faults, and other uncategorized faults. The control fault models simulate impacts of inappropriate thermostat control schemes such as an incorrect thermostat set point in unoccupied hours and manual changes of thermostat set point due to extreme outside temperature. Sensor fault models focus on the modeling of sensor biases including economizer relative humidity sensor bias, supply air temperature sensor bias, and water circuit temperature sensor bias. Packaged and split air conditioner fault models simulate refrigerant undercharging, condenser fouling, condenser fan motor efficiency degradation, non-condensable entrainment in refrigerant, and liquid line restriction. Other fault models that are uncategorized include duct fouling, excessive infiltration into the building, and blower and pump motor degradation.

  8. Geology of Joshua Tree National Park geodatabase

    Science.gov (United States)

    Powell, Robert E.; Matti, Jonathan C.; Cossette, Pamela M.

    2015-09-16

    The database in this Open-File Report describes the geology of Joshua Tree National Park and was completed in support of the National Cooperative Geologic Mapping Program of the U.S. Geological Survey (USGS) and in cooperation with the National Park Service (NPS). The geologic observations and interpretations represented in the database are relevant to both the ongoing scientific interests of the USGS in southern California and the management requirements of NPS, specifically of Joshua Tree National Park (JOTR).Joshua Tree National Park is situated within the eastern part of California’s Transverse Ranges province and straddles the transition between the Mojave and Sonoran deserts. The geologically diverse terrain that underlies JOTR reveals a rich and varied geologic evolution, one that spans nearly two billion years of Earth history. The Park’s landscape is the current expression of this evolution, its varied landforms reflecting the differing origins of underlying rock types and their differing responses to subsequent geologic events. Crystalline basement in the Park consists of Proterozoic plutonic and metamorphic rocks intruded by a composite Mesozoic batholith of Triassic through Late Cretaceous plutons arrayed in northwest-trending lithodemic belts. The basement was exhumed during the Cenozoic and underwent differential deep weathering beneath a low-relief erosion surface, with the deepest weathering profiles forming on quartz-rich, biotite-bearing granitoid rocks. Disruption of the basement terrain by faults of the San Andreas system began ca. 20 Ma and the JOTR sinistral domain, preceded by basalt eruptions, began perhaps as early as ca. 7 Ma, but no later than 5 Ma. Uplift of the mountain blocks during this interval led to erosional stripping of the thick zones of weathered quartz-rich granitoid rocks to form etchplains dotted by bouldery tors—the iconic landscape of the Park. The stripped debris filled basins along the fault zones.Mountain ranges

  9. Application of condition-based HRA method for a manual actuation of the safety features in a nuclear power Plant

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Jang, Seung-Cheol

    2006-01-01

    A practical approach to develop a more realistic fault-tree model with a consideration of various conditions endured by a human operator is proposed. In safety-critical systems, the generation failure of an actuation signal is caused by the concurrent failures of the automated systems and an operator action. These two sources of safety signals are complicatedly correlated. The failures of sensors or automated systems will cause a lack of necessary information for a human operator and result in error-forcing contexts such as the loss of corresponding alarms and indications. It is well known that the error-forcing contexts largely affect the operator's performance. An automated system which consists of multiple processing channels and complex components is also affected by the availability of the sensors. This paper proposes a condition-based human reliability assessment (CBHRA) method in order to address these complicated conditions in a practical way. We apply the CBHRA method to the manual actuation of the safety features such as a reactor trip and auxiliary feedwater actuation in Korean Standard Nuclear Power Plants. Even the human error probability of each given condition is simply assumed, the application results prove that the CBHRA effectively accommodates the complicated error-forcing contexts into the fault trees

  10. Intelligent condition monitoring method for bearing faults from highly compressed measurements using sparse over-complete features

    Science.gov (United States)

    Ahmed, H. O. A.; Wong, M. L. D.; Nandi, A. K.

    2018-01-01

    Condition classification of rolling element bearings in rotating machines is important to prevent the breakdown of industrial machinery. A considerable amount of literature has been published on bearing faults classification. These studies aim to determine automatically the current status of a roller element bearing. Of these studies, methods based on compressed sensing (CS) have received some attention recently due to their ability to allow one to sample below the Nyquist sampling rate. This technology has many possible uses in machine condition monitoring and has been investigated as a possible approach for fault detection and classification in the compressed domain, i.e., without reconstructing the original signal. However, previous CS based methods have been found to be too weak for highly compressed data. The present paper explores computationally, for the first time, the effects of sparse autoencoder based over-complete sparse representations on the classification performance of highly compressed measurements of bearing vibration signals. For this study, the CS method was used to produce highly compressed measurements of the original bearing dataset. Then, an effective deep neural network (DNN) with unsupervised feature learning algorithm based on sparse autoencoder is used for learning over-complete sparse representations of these compressed datasets. Finally, the fault classification is achieved using two stages, namely, pre-training classification based on stacked autoencoder and softmax regression layer form the deep net stage (the first stage), and re-training classification based on backpropagation (BP) algorithm forms the fine-tuning stage (the second stage). The experimental results show that the proposed method is able to achieve high levels of accuracy even with extremely compressed measurements compared with the existing techniques.

  11. Multi-Fault Rupture Scenarios in the Brawley Seismic Zone

    Science.gov (United States)

    Kyriakopoulos, C.; Oglesby, D. D.; Rockwell, T. K.; Meltzner, A. J.; Barall, M.

    2017-12-01

    Dynamic rupture complexity is strongly affected by both the geometric configuration of a network of faults and pre-stress conditions. Between those two, the geometric configuration is more likely to be anticipated prior to an event. An important factor in the unpredictability of the final rupture pattern of a group of faults is the time-dependent interaction between them. Dynamic rupture models provide a means to investigate this otherwise inscrutable processes. The Brawley Seismic Zone in Southern California is an area in which this approach might be important for inferring potential earthquake sizes and rupture patterns. Dynamic modeling can illuminate how the main faults in this area, the Southern San Andreas (SSAF) and Imperial faults, might interact with the intersecting cross faults, and how the cross faults may modulate rupture on the main faults. We perform 3D finite element modeling of potential earthquakes in this zone assuming an extended array of faults (Figure). Our results include a wide range of ruptures and fault behaviors depending on assumptions about nucleation location, geometric setup, pre-stress conditions, and locking depth. For example, in the majority of our models the cross faults do not strongly participate in the rupture process, giving the impression that they are not typically an aid or an obstacle to the rupture propagation. However, in some cases, particularly when rupture proceeds slowly on the main faults, the cross faults indeed can participate with significant slip, and can even cause rupture termination on one of the main faults. Furthermore, in a complex network of faults we should not preclude the possibility of a large event nucleating on a smaller fault (e.g. a cross fault) and eventually promoting rupture on the main structure. Recent examples include the 2010 Mw 7.1 Darfield (New Zealand) and Mw 7.2 El Mayor-Cucapah (Mexico) earthquakes, where rupture started on a smaller adjacent segment and later cascaded into a larger

  12. Distributed bearing fault diagnosis based on vibration analysis

    Science.gov (United States)

    Dolenc, Boštjan; Boškoski, Pavle; Juričić, Đani

    2016-01-01

    Distributed bearing faults appear under various circumstances, for example due to electroerosion or the progression of localized faults. Bearings with distributed faults tend to generate more complex vibration patterns than those with localized faults. Despite the frequent occurrence of such faults, their diagnosis has attracted limited attention. This paper examines a method for the diagnosis of distributed bearing faults employing vibration analysis. The vibrational patterns generated are modeled by incorporating the geometrical imperfections of the bearing components. Comparing envelope spectra of vibration signals shows that one can distinguish between localized and distributed faults. Furthermore, a diagnostic procedure for the detection of distributed faults is proposed. This is evaluated on several bearings with naturally born distributed faults, which are compared with fault-free bearings and bearings with localized faults. It is shown experimentally that features extracted from vibrations in fault-free, localized and distributed fault conditions form clearly separable clusters, thus enabling diagnosis.

  13. Fundamental problems in fault detection and identification

    DEFF Research Database (Denmark)

    Saberi, Ali; Stoorvogel, Anton A.; Sannuti, Peddapullaiah

    1999-01-01

    For certain fundamental problems in fault detection and identification, the necessary and sufficient conditions for their solvability are derived. These conditions are weaker than the ones found in the literature, since we do not assume any particular structure for the residual generator......For certain fundamental problems in fault detection and identification, the necessary and sufficient conditions for their solvability are derived. These conditions are weaker than the ones found in the literature, since we do not assume any particular structure for the residual generator...

  14. Comparison between AOT40 and ozone uptake in forest trees of different species, age and site conditions

    Science.gov (United States)

    Matyssek, R.; Wieser, G.; Nunn, A. J.; Kozovits, A. R.; Reiter, I. M.; Heerdt, C.; Winkler, J. B.; Baumgarten, M.; Häberle, K.-H.; Grams, T. E. E.; Werner, H.; Fabian, P.; Havranek, W. M.

    The current AOT40 concept for inferring risks in forest trees by ozone (O 3) injury is based on an accumulated external O 3 exposure rather than an internal O 3 dose or uptake rate. AOT40 assumes O 3 concentrations below 40 nl l -1 and night-time exposure to be negligible. Hence, this concept is rather inconsistent with observed forest conditions. In contrast, the flux concept of cumulative O 3 uptake (CU) into the leaves has the potential of reflecting a physiologically meaningful internal O 3 dose experienced by trees. In this paper, we relate AOT40 to cumulative O 3 uptake into European beech ( Fagus sylvatica), Norway spruce ( Picea abies), European larch ( Larix decidua) and cembran pine ( Pinus cembra) trees differing in size, age and site conditions. We demonstrate that the flux concept can be extended to the tree and the stand level, making use of sap flow measurements through tree trunks. Although in both seedlings and adult trees AOT40 may show some linearity in correlations with average CU, the latter varies, at given AOT40, by 25±11% within and between species. This is because O 3 flux is primarily influenced by stomatal aperture, the latter being affected by climate, canopy position, leaf and tree age while varying between species. In particular, if weighed by detoxification capacity, we suggest, therefore, O 3 uptake related air quality indices to be promoted towards ecologically meaningful standards in forest protection, overcoming the shortcomings of exposure concepts. As O 3 injury results from the balance between O 3 uptake and detoxification in the leaf mesophyll, we conclude the flux concept in combination with measures of biochemical defence to have the capacity for predicting tree response to O 3 stress.

  15. Effect Analysis of Faults in Digital I and C Systems of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jun; Jung, Won Dea [KAERI, Dajeon (Korea, Republic of); Kim, Man Cheol [Chung-Ang University, Seoul (Korea, Republic of)

    2014-08-15

    A reliability analysis of digital instrumentation and control (I and C) systems in nuclear power plants has been introduced as one of the important elements of a probabilistic safety assessment because of the unique characteristics of digital I and C systems. Digital I and C systems have various features distinguishable from those of analog I and C systems such as software and fault-tolerant techniques. In this work, the faults in a digital I and C system were analyzed and a model for representing the effects of the faults was developed. First, the effects of the faults in a system were analyzed using fault injection experiments. A software-implemented fault injection technique in which faults can be injected into the memory was used based on the assumption that all faults in a system are reflected in the faults in the memory. In the experiments, the effect of a fault on the system output was observed. In addition, the success or failure in detecting the fault by fault-tolerant functions included in the system was identified. Second, a fault tree model for representing that a fault is propagated to the system output was developed. With the model, it can be identified how a fault is propagated to the output or why a fault is not detected by fault-tolerant techniques. Based on the analysis results of the proposed method, it is possible to not only evaluate the system reliability but also identify weak points of fault-tolerant techniques by identifying undetected faults. The results can be reflected in the designs to improve the capability of fault-tolerant techniques.

  16. Effect analysis of faults in digital I and C systems of nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Jun

    2014-01-01

    A reliability analysis of digital instrumentation and control (I and C) systems in nuclear power plants has been introduced as one of the important elements of a probabilistic safety assessment because of the unique characteristics of digital I and C systems. Digital I and C systems have various features distinguishable from those of analog I and C systems such as software and fault-tolerant techniques. In this work, the faults in a digital I and C system were analyzed and a model for representing the effects of the faults was developed. First, the effects of the faults in a system were analyzed using fault injection experiments. A software-implemented fault injection technique in which faults can be injected into the memory was used based on the assumption that all faults in a system are reflected in the faults in the memory. In the experiments, the effect of a fault on the system output was observed. In addition, the success or failure in detecting the fault by fault-tolerant functions included in the system was identified. Second, a fault tree model for representing that a fault is propagated to the system output was developed. With the model, it can be identified how a fault is propagated to the output or why a fault is not detected by fault-tolerant techniques. Based on the analysis results of the proposed method, it is possible to not only evaluate the system reliability but also identify weak points of fault-tolerant techniques by identifying undetected faults. The results can be reflected in the designs to improve the capability of fault-tolerant techniques. (author)

  17. The influence of prefire tree growth and crown condition on postfire mortality of sugar pine following prescribed fire in Sequoia National Park

    Science.gov (United States)

    Nesmith, Jonathan C. B.; Das, Adrian J.; O'Hara, Kevin L.; van Mantgem, Phillip J.

    2015-01-01

    Tree mortality is a vital component of forest management in the context of prescribed fires; however, few studies have examined the effect of prefire tree health on postfire mortality. This is especially relevant for sugar pine (Pinus lambertiana Douglas), a species experiencing population declines due to a suite of anthropogenic factors. Using data from an old-growth mixed-conifer forest in Sequoia National Park, we evaluated the effects of fire, tree size, prefire radial growth, and crown condition on postfire mortality. Models based only on tree size and measures of fire damage were compared with models that included tree size, fire damage, and prefire tree health (e.g., measures of prefire tree radial growth or crown condition). Immediately following the fire, the inclusion of different metrics of prefire tree health produced variable improvements over the models that included only tree size and measures of fire damage, as models that included measures of crown condition performed better than fire-only models, but models that included measures of prefire radial growth did not perform better. However, 5 years following the fire, sugar pine mortality was best predicted by models that included measures of both fire damage and prefire tree health, specifically, diameter at breast height (DBH, 1.37 m), crown scorch, 30-year mean growth, and the number of sharp declines in growth over a 30-year period. This suggests that factors that influence prefire tree health (e.g., drought, competition, pathogens, etc.) may partially determine postfire mortality, especially when accounting for delayed mortality following fire.

  18. Fault Analysis in Solar Photovoltaic Arrays

    Science.gov (United States)

    Zhao, Ye

    Fault analysis in solar photovoltaic (PV) arrays is a fundamental task to increase reliability, efficiency and safety in PV systems. Conventional fault protection methods usually add fuses or circuit breakers in series with PV components. But these protection devices are only able to clear faults and isolate faulty circuits if they carry a large fault current. However, this research shows that faults in PV arrays may not be cleared by fuses under some fault scenarios, due to the current-limiting nature and non-linear output characteristics of PV arrays. First, this thesis introduces new simulation and analytic models that are suitable for fault analysis in PV arrays. Based on the simulation environment, this thesis studies a variety of typical faults in PV arrays, such as ground faults, line-line faults, and mismatch faults. The effect of a maximum power point tracker on fault current is discussed and shown to, at times, prevent the fault current protection devices to trip. A small-scale experimental PV benchmark system has been developed in Northeastern University to further validate the simulation conclusions. Additionally, this thesis examines two types of unique faults found in a PV array that have not been studied in the literature. One is a fault that occurs under low irradiance condition. The other is a fault evolution in a PV array during night-to-day transition. Our simulation and experimental results show that overcurrent protection devices are unable to clear the fault under "low irradiance" and "night-to-day transition". However, the overcurrent protection devices may work properly when the same PV fault occurs in daylight. As a result, a fault under "low irradiance" and "night-to-day transition" might be hidden in the PV array and become a potential hazard for system efficiency and reliability.

  19. ANALISA PENYEBAB PENURUNAN DAYA SAING PRODUK SUSU SAPI DALAM NEGERI TERHADAP SUSU SAPI IMPOR PADA INDUSTRI PENGOLAHAN SUSU (IPS DENGAN METODE FAULT TREE ANALYSIS (FTA DAN BARRIER ANALYSIS

    Directory of Open Access Journals (Sweden)

    Susatyo Nugroho W.P

    2012-02-01

    , troubleshooting     Indonesian dairy products are required to compete with products of other countries, not to compete on international markets but that the Indonesian domestic market. But the conditions that exist at this ndtime, local dairy milk products are not able to meet the demand quantity Milk Processing Industries (IPS, quality does not meet the standard codex milk, and milk prices are higher than imports, making local farmers unable to compete with dairy-exporting countries world. IPS in Indonesia prefer to use imported milk with better quality and cheaper prices than local milk. Given the geograph and ecology of the land in Indonesia was suitable for the development of dairy cattle (dairy agribusiness and the huge domestic demand for milk, dairy cattle Indonesia actually can be more competitive. It is therefore important to do an analysis to identify the root cause of the problem of low competitiveness of Indonesian cow's milk to cow's milk imports in the IPS. The analysis method used was analysis by Fault Tree Analysis (FTA to determine the root cause of a problem. While Barrier Analysis is a systematic process used to identify physical barriers, administrative and control procedures or precautionary measures to prevent the problems that the problem occurs again. Results of analysis showed the main problem is more dominant livestock affected by internal factors alone. By studying the root causes of problems, made ​​troubleshooting that contains troubleshooting tips for when problems occur again either troubleshooting the problems of productivity, quantity, price of local fresh milk which is not competitive against imports of fresh milk and recommend remedial action that includes aspects of man, method, material, machine , mother nature, and maintenance. Keywords : competitiveness, fault tree analysis, barrier analysis, troubleshooting.

  20. Automated Generation of Fault Management Artifacts from a Simple System Model

    Science.gov (United States)

    Kennedy, Andrew K.; Day, John C.

    2013-01-01

    Our understanding of off-nominal behavior - failure modes and fault propagation - in complex systems is often based purely on engineering intuition; specific cases are assessed in an ad hoc fashion as a (fallible) fault management engineer sees fit. This work is an attempt to provide a more rigorous approach to this understanding and assessment by automating the creation of a fault management artifact, the Failure Modes and Effects Analysis (FMEA) through querying a representation of the system in a SysML model. This work builds off the previous development of an off-nominal behavior model for the upcoming Soil Moisture Active-Passive (SMAP) mission at the Jet Propulsion Laboratory. We further developed the previous system model to more fully incorporate the ideas of State Analysis, and it was restructured in an organizational hierarchy that models the system as layers of control systems while also incorporating the concept of "design authority". We present software that was developed to traverse the elements and relationships in this model to automatically construct an FMEA spreadsheet. We further discuss extending this model to automatically generate other typical fault management artifacts, such as Fault Trees, to efficiently portray system behavior, and depend less on the intuition of fault management engineers to ensure complete examination of off-nominal behavior.

  1. Fault Diagnosis for Actuators in a Class of Nonlinear Systems Based on an Adaptive Fault Detection Observer

    Directory of Open Access Journals (Sweden)

    Runxia Guo

    2016-01-01

    Full Text Available The problem of actuators’ fault diagnosis is pursued for a class of nonlinear control systems that are affected by bounded measurement noise and external disturbances. A novel fault diagnosis algorithm has been proposed by combining the idea of adaptive control theory and the approach of fault detection observer. The asymptotical stability of the fault detection observer is guaranteed by setting the adaptive adjusting law of the unknown fault vector. A theoretically rigorous proof of asymptotical stability has been given. Under the condition that random measurement noise generated by the sensors of control systems and external disturbances exist simultaneously, the designed fault diagnosis algorithm is able to successfully give specific estimated values of state variables and failures rather than just giving a simple fault warning. Moreover, the proposed algorithm is very simple and concise and is easy to be applied to practical engineering. Numerical experiments are carried out to evaluate the performance of the fault diagnosis algorithm. Experimental results show that the proposed diagnostic strategy has a satisfactory estimation effect.

  2. Fault Diagnosis of Plunger Pump in Truck Crane Based on Relevance Vector Machine with Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Wenliao Du

    2013-01-01

    Full Text Available Promptly and accurately dealing with the equipment breakdown is very important in terms of enhancing reliability and decreasing downtime. A novel fault diagnosis method PSO-RVM based on relevance vector machines (RVM with particle swarm optimization (PSO algorithm for plunger pump in truck crane is proposed. The particle swarm optimization algorithm is utilized to determine the kernel width parameter of the kernel function in RVM, and the five two-class RVMs with binary tree architecture are trained to recognize the condition of mechanism. The proposed method is employed in the diagnosis of plunger pump in truck crane. The six states, including normal state, bearing inner race fault, bearing roller fault, plunger wear fault, thrust plate wear fault, and swash plate wear fault, are used to test the classification performance of the proposed PSO-RVM model, which compared with the classical models, such as back-propagation artificial neural network (BP-ANN, ant colony optimization artificial neural network (ANT-ANN, RVM, and support vectors, machines with particle swarm optimization (PSO-SVM, respectively. The experimental results show that the PSO-RVM is superior to the first three classical models, and has a comparative performance to the PSO-SVM, the corresponding diagnostic accuracy achieving as high as 99.17% and 99.58%, respectively. But the number of relevance vectors is far fewer than that of support vector, and the former is about 1/12–1/3 of the latter, which indicates that the proposed PSO-RVM model is more suitable for applications that require low complexity and real-time monitoring.

  3. Initial growth of Bauhinia variegata trees under different colored shade nets and light conditions

    Directory of Open Access Journals (Sweden)

    Renata Bachin Mazzini-Guedes

    2014-12-01

    Full Text Available Bauhinia variegata and B. variegata var. candida, commonly known as orchid trees, are small sized trees widely used for urban forestry and landscaping. Adult plants grow under full sun; in Brazil, however, seedlings are generally cultivated in commercial nurseries under natural half-shading. The objective of this study was to evaluate the influence of different colored shade nets and light conditions on the initial growth of B. variegata and B. variegata var. candida. The influence of six light conditions (red net with 50% shading; blue net with 50% shading; black net with 70% shading; black net with 50% shading; black net with 30% shading; and full sun on the initial growth of B. variegata and B. variegata var. candida were evaluated along 160 days, and growth relationships were calculated. Seedlings showed more efficiency on the use of photoassimilated compounds when grown under full sun. Such condition is the most appropriate for seedling production of B. variegata and B. variegata var. candida, contradicting what has been performed in practice.

  4. Nitrogen and phosphorus economy of a legume tree-cereal intercropping system under controlled conditions

    International Nuclear Information System (INIS)

    Isaac, M.E.; Hinsinger, P.; Harmand, J.M.

    2012-01-01

    Considerable amounts of nitrogen (N) and phosphorus (P) fertilizers have been mis-used in agroecosystems, with profound alteration to the biogeochemical cycles of these two major nutrients. To reduce excess fertilizer use, plant-mediated nutrient supply through N 2 -fixation, transfer of fixed N and mobilization of soil P may be important processes for the nutrient economy of low-input tree-based intercropping systems. In this study, we quantified plant performance, P acquisition and belowground N transfer from the N 2 -fixing tree to the cereal crop under varying root contact intensity and P supplies. We cultivated Acacia senegal var senegal in pot-culture containing 90% sand and 10% vermiculite under 3 levels of exponentially supplied P. Acacia plants were then intercropped with durum wheat (Triticum turgidum durum) in the same pots with variable levels of adsorbed P or transplanted and intercropped with durum wheat in rhizoboxes excluding direct root contact on P-poor red Mediterranean soils. In pot-culture, wheat biomass and P content increased in relation to the P gradient. Strong isotopic evidence of belowground N transfer, based on the isotopic signature (δ 15 N) of tree foliage and wheat shoots, was systematically found under high P in pot-culture, with an average N transfer value of 14.0% of wheat total N after 21 days of contact between the two species. In the rhizoboxes, we observed limitations on growth and P uptake of intercropped wheat due to competitive effects on soil resources and minimal evidence of belowground N transfer of N from acacia to wheat. In this intercrop, specifically in pot-culture, facilitation for N transfer from the legume tree to the crop showed to be effective especially when crop N uptake was increased (or stimulated) as occurred under high P conditions and when competition was low. Understanding these processes is important to the nutrient economy and appropriate management of legume-based agroforestry systems. -- Highlights

  5. Modeling and Fault Simulation of Propellant Filling System

    International Nuclear Information System (INIS)

    Jiang Yunchun; Liu Weidong; Hou Xiaobo

    2012-01-01

    Propellant filling system is one of the key ground plants in launching site of rocket that use liquid propellant. There is an urgent demand for ensuring and improving its reliability and safety, and there is no doubt that Failure Mode Effect Analysis (FMEA) is a good approach to meet it. Driven by the request to get more fault information for FMEA, and because of the high expense of propellant filling, in this paper, the working process of the propellant filling system in fault condition was studied by simulating based on AMESim. Firstly, based on analyzing its structure and function, the filling system was modular decomposed, and the mathematic models of every module were given, based on which the whole filling system was modeled in AMESim. Secondly, a general method of fault injecting into dynamic system was proposed, and as an example, two typical faults - leakage and blockage - were injected into the model of filling system, based on which one can get two fault models in AMESim. After that, fault simulation was processed and the dynamic characteristics of several key parameters were analyzed under fault conditions. The results show that the model can simulate effectively the two faults, and can be used to provide guidance for the filling system maintain and amelioration.

  6. Naive Bayes Bearing Fault Diagnosis Based on Enhanced Independence of Data.

    Science.gov (United States)

    Zhang, Nannan; Wu, Lifeng; Yang, Jing; Guan, Yong

    2018-02-05

    The bearing is the key component of rotating machinery, and its performance directly determines the reliability and safety of the system. Data-based bearing fault diagnosis has become a research hotspot. Naive Bayes (NB), which is based on independent presumption, is widely used in fault diagnosis. However, the bearing data are not completely independent, which reduces the performance of NB algorithms. In order to solve this problem, we propose a NB bearing fault diagnosis method based on enhanced independence of data. The method deals with data vector from two aspects: the attribute feature and the sample dimension. After processing, the classification limitation of NB is reduced by the independence hypothesis. First, we extract the statistical characteristics of the original signal of the bearings effectively. Then, the Decision Tree algorithm is used to select the important features of the time domain signal, and the low correlation features is selected. Next, the Selective Support Vector Machine (SSVM) is used to prune the dimension data and remove redundant vectors. Finally, we use NB to diagnose the fault with the low correlation data. The experimental results show that the independent enhancement of data is effective for bearing fault diagnosis.

  7. Naive Bayes Bearing Fault Diagnosis Based on Enhanced Independence of Data

    Science.gov (United States)

    Zhang, Nannan; Wu, Lifeng; Yang, Jing; Guan, Yong

    2018-01-01

    The bearing is the key component of rotating machinery, and its performance directly determines the reliability and safety of the system. Data-based bearing fault diagnosis has become a research hotspot. Naive Bayes (NB), which is based on independent presumption, is widely used in fault diagnosis. However, the bearing data are not completely independent, which reduces the performance of NB algorithms. In order to solve this problem, we propose a NB bearing fault diagnosis method based on enhanced independence of data. The method deals with data vector from two aspects: the attribute feature and the sample dimension. After processing, the classification limitation of NB is reduced by the independence hypothesis. First, we extract the statistical characteristics of the original signal of the bearings effectively. Then, the Decision Tree algorithm is used to select the important features of the time domain signal, and the low correlation features is selected. Next, the Selective Support Vector Machine (SSVM) is used to prune the dimension data and remove redundant vectors. Finally, we use NB to diagnose the fault with the low correlation data. The experimental results show that the independent enhancement of data is effective for bearing fault diagnosis. PMID:29401730

  8. Detection, diagnosis, and treatment of accident conditions using response trees

    International Nuclear Information System (INIS)

    Nelson, W.R.

    1980-01-01

    Response Trees were developed at the LOFT facility in 1978 and included in the Plant Operating Manual (POM) to assist reactor operators in selecting emergency procedures. In an emergency situation the operator would manually gather data and evaluate the trees to select the appropriate procedures. As a portion of the LOFT Augmented Operator Capability (AOC) Program, the response tree methodology has been extended so that a computer can be used to evaluate the trees and recommend an appropriate response for an accident. Techniques for diagnosing failures within a cooling mode have also been investigated. This paper summarizes these additions to the response tree methodology

  9. Fault morphology of the lyo Fault, the Median Tectonic Line Active Fault System

    OpenAIRE

    後藤, 秀昭

    1996-01-01

    In this paper, we investigated the various fault features of the lyo fault and depicted fault lines or detailed topographic map. The results of this paper are summarized as follows; 1) Distinct evidence of the right-lateral movement is continuously discernible along the lyo fault. 2) Active fault traces are remarkably linear suggesting that the angle of fault plane is high. 3) The lyo fault can be divided into four segments by jogs between left-stepping traces. 4) The mean slip rate is 1.3 ~ ...

  10. Induced Voltages Ratio-Based Algorithm for Fault Detection, and Faulted Phase and Winding Identification of a Three-Winding Power Transformer

    Directory of Open Access Journals (Sweden)

    Byung Eun Lee

    2014-09-01

    Full Text Available This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system. The ratio of the induced voltages of the primary-secondary, primary-tertiary and secondary-tertiary windings is the same as the corresponding turns ratio during normal operating conditions, magnetic inrush, and over-excitation. It differs from the turns ratio during an internal fault. For a single phase and a three-phase power transformer with wye-connected windings, the induced voltages of each pair of windings are estimated. For a three-phase power transformer with delta-connected windings, the induced voltage differences are estimated to use the line currents, because the delta winding currents are practically unavailable. Six detectors are suggested for fault detection. An additional three detectors and a rule for faulted phase and winding identification are presented as well. The proposed algorithm can not only detect an internal fault, but also identify the faulted phase and winding of a three-winding power transformer. The various test results with Electromagnetic Transients Program (EMTP-generated data show that the proposed algorithm successfully discriminates internal faults from normal operating conditions including magnetic inrush and over-excitation. This paper concludes by implementing the algorithm into a prototype relay based on a digital signal processor.

  11. FUZZY FAULT DETECTION FOR PERMANENT MAGNET SYNCHRONOUS GENERATOR

    Directory of Open Access Journals (Sweden)

    N. Selvaganesan

    2011-07-01

    Full Text Available Faults in engineering systems are difficult to avoid and may result in serious consequences. Effective fault detection and diagnosis can improve system reliability and avoid expensive maintenance. In this paper fuzzy system based fault detection scheme for permanent magnet synchronous generator is proposed. The sequence current components like positive and negative sequence currents are used as fault indicators and given as inputs to fuzzy fault detector. Also, the fuzzy inference system is created and rule base is evaluated, relating the sequence current component to the type of faults. These rules are fired for specific changes in sequence current component and the faults are detected. The feasibility of the proposed scheme for permanent magnet synchronous generator is demonstrated for different types of fault under various operating conditions using MATLAB/Simulink.

  12. Intelligent fault diagnosis of rolling bearing based on kernel neighborhood rough sets and statistical features

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiao Ran; Zhang, You Yun; Zhu, Yong Sheng [Xi' an Jiaotong Univ., Xi' an (China)

    2012-09-15

    Intelligent fault diagnosis benefits from efficient feature selection. Neighborhood rough sets are effective in feature selection. However, determining the neighborhood value accurately remains a challenge. The wrapper feature selection algorithm is designed by combining the kernel method and neighborhood rough sets to self-adaptively select sensitive features. The combination effectively solves the shortcomings in selecting the neighborhood value in the previous application process. The statistical features of time and frequency domains are used to describe the characteristic of the rolling bearing to make the intelligent fault diagnosis approach work. Three classification algorithms, namely, classification and regression tree (CART), commercial version 4.5 (C4.5), and radial basis function support vector machines (RBFSVM), are used to test UCI datasets and 10 fault datasets of rolling bearing. The results indicate that the diagnostic approach presented could effectively select the sensitive fault features and simultaneously identify the type and degree of the fault.

  13. Intelligent fault diagnosis of rolling bearing based on kernel neighborhood rough sets and statistical features

    International Nuclear Information System (INIS)

    Zhu, Xiao Ran; Zhang, You Yun; Zhu, Yong Sheng

    2012-01-01

    Intelligent fault diagnosis benefits from efficient feature selection. Neighborhood rough sets are effective in feature selection. However, determining the neighborhood value accurately remains a challenge. The wrapper feature selection algorithm is designed by combining the kernel method and neighborhood rough sets to self-adaptively select sensitive features. The combination effectively solves the shortcomings in selecting the neighborhood value in the previous application process. The statistical features of time and frequency domains are used to describe the characteristic of the rolling bearing to make the intelligent fault diagnosis approach work. Three classification algorithms, namely, classification and regression tree (CART), commercial version 4.5 (C4.5), and radial basis function support vector machines (RBFSVM), are used to test UCI datasets and 10 fault datasets of rolling bearing. The results indicate that the diagnostic approach presented could effectively select the sensitive fault features and simultaneously identify the type and degree of the fault

  14. Dynamic modeling of gearbox faults: A review

    Science.gov (United States)

    Liang, Xihui; Zuo, Ming J.; Feng, Zhipeng

    2018-01-01

    Gearbox is widely used in industrial and military applications. Due to high service load, harsh operating conditions or inevitable fatigue, faults may develop in gears. If the gear faults cannot be detected early, the health will continue to degrade, perhaps causing heavy economic loss or even catastrophe. Early fault detection and diagnosis allows properly scheduled shutdowns to prevent catastrophic failure and consequently result in a safer operation and higher cost reduction. Recently, many studies have been done to develop gearbox dynamic models with faults aiming to understand gear fault generation mechanism and then develop effective fault detection and diagnosis methods. This paper focuses on dynamics based gearbox fault modeling, detection and diagnosis. State-of-art and challenges are reviewed and discussed. This detailed literature review limits research results to the following fundamental yet key aspects: gear mesh stiffness evaluation, gearbox damage modeling and fault diagnosis techniques, gearbox transmission path modeling and method validation. In the end, a summary and some research prospects are presented.

  15. Goal-Function Tree Modeling for Systems Engineering and Fault Management

    Science.gov (United States)

    Johnson, Stephen B.; Breckenridge, Jonathan T.

    2013-01-01

    The draft NASA Fault Management (FM) Handbook (2012) states that Fault Management (FM) is a "part of systems engineering", and that it "demands a system-level perspective" (NASAHDBK- 1002, 7). What, exactly, is the relationship between systems engineering and FM? To NASA, systems engineering (SE) is "the art and science of developing an operable system capable of meeting requirements within often opposed constraints" (NASA/SP-2007-6105, 3). Systems engineering starts with the elucidation and development of requirements, which set the goals that the system is to achieve. To achieve these goals, the systems engineer typically defines functions, and the functions in turn are the basis for design trades to determine the best means to perform the functions. System Health Management (SHM), by contrast, defines "the capabilities of a system that preserve the system's ability to function as intended" (Johnson et al., 2011, 3). Fault Management, in turn, is the operational subset of SHM, which detects current or future failures, and takes operational measures to prevent or respond to these failures. Failure, in turn, is the "unacceptable performance of intended function." (Johnson 2011, 605) Thus the relationship of SE to FM is that SE defines the functions and the design to perform those functions to meet system goals and requirements, while FM detects the inability to perform those functions and takes action. SHM and FM are in essence "the dark side" of SE. For every function to be performed (SE), there is the possibility that it is not successfully performed (SHM); FM defines the means to operationally detect and respond to this lack of success. We can also describe this in terms of goals: for every goal to be achieved, there is the possibility that it is not achieved; FM defines the means to operationally detect and respond to this inability to achieve the goal. This brief description of relationships between SE, SHM, and FM provide hints to a modeling approach to

  16. Fault strength in Marmara region inferred from the geometry of the principle stress axes and fault orientations: A case study for the Prince's Islands fault segment

    Science.gov (United States)

    Pinar, Ali; Coskun, Zeynep; Mert, Aydin; Kalafat, Dogan

    2015-04-01

    The general consensus based on historical earthquake data point out that the last major moment release on the Prince's islands fault was in 1766 which in turn signals an increased seismic risk for Istanbul Metropolitan area considering the fact that most of the 20 mm/yr GPS derived slip rate for the region is accommodated mostly by that fault segment. The orientation of the Prince's islands fault segment overlaps with the NW-SE direction of the maximum principle stress axis derived from the focal mechanism solutions of the large and moderate sized earthquakes occurred in the Marmara region. As such, the NW-SE trending fault segment translates the motion between the two E-W trending branches of the North Anatolian fault zone; one extending from the Gulf of Izmit towards Çınarcık basin and the other extending between offshore Bakırköy and Silivri. The basic relation between the orientation of the maximum and minimum principal stress axes, the shear and normal stresses, and the orientation of a fault provides clue on the strength of a fault, i.e., its frictional coefficient. Here, the angle between the fault normal and maximum compressive stress axis is a key parameter where fault normal and fault parallel maximum compressive stress might be a necessary and sufficient condition for a creeping event. That relation also implies that when the trend of the sigma-1 axis is close to the strike of the fault the shear stress acting on the fault plane approaches zero. On the other hand, the ratio between the shear and normal stresses acting on a fault plane is proportional to the coefficient of frictional coefficient of the fault. Accordingly, the geometry between the Prince's islands fault segment and a maximum principal stress axis matches a weak fault model. In the frame of the presentation we analyze seismological data acquired in Marmara region and interpret the results in conjuction with the above mentioned weak fault model.

  17. Fault Management of a Cold Dielectric HTS Power Transmission Cable

    International Nuclear Information System (INIS)

    Maguire, J; Allais, A; Yuan, J; Schmidt, F; Hamber, F; Welsh, Tom

    2006-01-01

    High temperature superconductor (HTS) power transmission cables offer significant advantages in power density over conventional copper-based cables. As with conventional cables, HTS cables must be safe and reliable when abnormal conditions, such as local and through faults, occur in the power grid. Due to the unique characteristics of HTS power cables, the fault management of an HTS cable is different from that of a conventional cable. Issues, such as nitrogen bubble formation within lapped dielectric material, need to be addressed. This paper reviews the efforts that have been performed to study the fault conditions of a cold dielectric HTS power cable. As a result of the efforts, a fault management scheme has been developed, which provides both local and through faults system protection. Details of the fault management scheme with examples are presented

  18. Tree age, fruit size and storage conditions affect levels of ascorbic acid, total phenolic concentrations and total antioxidant activity of 'Kinnow' mandarin juice.

    Science.gov (United States)

    Khalid, Samina; Malik, Aman U; Khan, Ahmad S; Shahid, Muhammad; Shafique, Muhammad

    2016-03-15

    Bioactive compounds (ascorbic acid, total phenolics and total antioxidants) are important constituents of citrus fruit juice; however, information with regard to their concentrations and changes in relation to tree age and storage conditions is limited. 'Kinnow' (Citrus nobilis Lour × Citrus deliciosa Tenora) mandarin juice from fruit of three tree ages (6, 18 and 35 years old) and fruit sizes (large, medium and small) were examined for their bioactive compounds during 7 days under ambient storage conditions (20 ± 2 °C and 60-65% relative humidity (RH)) and during 60 days under cold storage (4 ± 1 °C and 75-80% RH) conditions. Under ambient conditions, a reduction in total phenolic concentrations (TPC) and in total antioxidant activity (TAA) was found for the juice from all tree ages and fruit sizes. Overall, fruit from 18-year-old trees had higher mean TPC (95.86 µg mL(-1) ) and TAA (93.68 mg L(-1) ), as compared to 6 and 35-year-old trees. Likewise, in cold storage, TAA decreased in all fruit size groups from 18 and 35-year-old trees. In all tree age and fruit size groups, TPC decreased initially during 15 days of cold storage and then increased gradually with increase in storage duration. Ascorbic acid concentrations showed an increasing trend in all fruit size groups from 35-year-old trees. Overall, during cold storage, fruit from 18-year-old trees maintained higher mean ascorbic acid (33.05 mg 100 mL(-1) ) concentrations, whereas fruit from 6-year-old trees had higher TAA (153.1 mg L(-1) ) and TPC (115.1 µg mL(-1) ). Large-sized fruit had higher ascorbic acid (32.08 mg 100 mL(-1) ) concentrations and TAA (157.5 mg L(-1) ). Fruit from 18-year-old trees maintained higher TPC and TAA under ambient storage conditions, whereas fruit from 6-year-old trees maintained higher TPC and TAA during cold storage. Small-sized fruit had higher TPC after ambient temperature storage, whereas large fruit size showed higher ascorbic acid concentrations and TAA after cold

  19. Computer modelling of superconductive fault current limiters

    Energy Technology Data Exchange (ETDEWEB)

    Weller, R.A.; Campbell, A.M.; Coombs, T.A.; Cardwell, D.A.; Storey, R.J. [Cambridge Univ. (United Kingdom). Interdisciplinary Research Centre in Superconductivity (IRC); Hancox, J. [Rolls Royce, Applied Science Division, Derby (United Kingdom)

    1998-05-01

    Investigations are being carried out on the use of superconductors for fault current limiting applications. A number of computer programs are being developed to predict the behavior of different `resistive` fault current limiter designs under a variety of fault conditions. The programs achieve solution by iterative methods based around real measured data rather than theoretical models in order to achieve accuracy at high current densities. (orig.) 5 refs.

  20. Characterizing the growth responses of three co-occurring northern conifer tree species to climate variation across a range of conditions

    Energy Technology Data Exchange (ETDEWEB)

    Green, S.; Miyamoto, Y. [Northern British Columbia Univ., Prince George, BC (Canada). Ecosystem Science and Management Program

    2006-07-01

    Climate is the key factor affecting tree growth. Trees regularly adapt to changing environmental conditions. Adjusting forest policies and practices under changing environments necessitates an understanding of species-specific tree responses to climate change. This paper discussed a study that examined the responses of 3 northern conifer tree species, notably the lodgepole pine, subalpine fir, and interior spruce. The purpose of the study was to characterize the climate sensitivities of each species growing under various environmental conditions, represented by mean annual temperatures and mean annual precipitations. The paper provided background information on climate change and tree species and discussed the objectives and implications of the study. Study methods were presented in detail and a geographical map showing the eight sampling sites located in central British Columbia and Yukon was also provided. Last, the paper provided the preliminary results and conclusions. It was found that the impacts of changing seasonal climates on tree growth will be species and site-specific. However, the magnitude of these differences were not completely analysed so that the impacts may be similar or significantly different among species or sites. 15 refs., 4 figs.