WorldWideScience

Sample records for fast extraction system

  1. Design of fast extraction system for the KEK proton synchrotron

    International Nuclear Information System (INIS)

    McCarthy, J.D.; Kimura, Yoshitaka.

    1975-03-01

    A fast beam extraction system is designed for the KEK 12 GeV Proton Synchrotron. The extraction is performed by the multi-turn beam shaving method in which hyper thin electrostatic septum inflectors are used as shaving elements. The beam loss and the emittance of the extracted beam are analyzed numerically as a function of thickness of the electrostatic septum wires. Specifications of the extraction elements, electrostatic septa, fast and slow bumps, and septum magnets, are given for the configuration of the designed system. (auth.)

  2. Development of alternate extractant systems for fast reactor fuel cycle

    International Nuclear Information System (INIS)

    Vasudeva Rao, P.R.; Suresh, A.; Venkatesan, K.A.; Srinivasan, T.G.; Raj, Baldev

    2007-01-01

    Due to the limitations of TBP in processing of high burn-up, Pu-rich fast reactor fuels, there is a need to develop alternate extractants for fast reactor fuel processing. In this context, our Centre has been examining the suitability of alternate tri-alkyl phosphates. Third phase formation in the extraction of Th(IV) by TBP, tri-n-amyl phosphate (TAP) and tri-2-methyl-butyl phosphate (T2MBP) from nitric acid media has been investigated under various conditions to derive conclusions on their application for extraction of Pu at macro levels. The chemical and radiolytic degradation of tri-n-amyl-phosphate (TAP) diluted in normal paraffin hydrocarbon (NPH) in the presence of nitric acid has been investigated by the measurement of plutonium retention in organic phase. The potential application of room temperature ionic liquids (RTILs) for reprocessing of spent nuclear fuel has been explored. Extraction of uranium (VI) and palladium (II) from nitric acid medium by commercially available RTIL and tri-n-butyl phosphate solution in RTIL have been studied and the feasibility of electrodeposition of uranium as uranium oxide (UO 2 ) and palladium (II) as metallic palladium from the loaded organic phase have been demonstrated. This paper describes results of the above studies and discusses the suitability of the systems for fast reactor fuel reprocessing. (authors)

  3. Design of extraction system in BRing at HIAF

    Science.gov (United States)

    Ruan, Shuang; Yang, Jiancheng; Zhang, Jinquan; Shen, Guodong; Ren, Hang; Liu, Jie; Shangguan, Jingbing; Zhang, Xiaoying; Zhang, Jingjing; Mao, Lijun; Sheng, Lina; Yin, Dayu; Wang, Geng; Wu, Bo; Yao, Liping; Tang, Meitang; Cai, Fucheng; Chen, Xiaoqiang

    2018-06-01

    The Booster Ring (BRing), which is the key part of HIAF (High Intensity heavy ion Accelerator Facility) complex at IMP (Institute of Modern Physics, Chinese Academy of Sciences), can provide uranium (A / q = 7) beam with a wide extraction energy range of 200-800 MeV/u. To fulfill a flexible beam extraction for multi-purpose experiments, both fast and slow extraction systems will be accommodated in the BRing. The fast extraction system is used for extracting short bunched beam horizontally in single-turn. The slow extraction system is used to provide quasi-continuous beam by the third order resonance and RF-knockout scheme. To achieve a compact structure, the two extraction systems are designed to share the same extraction channel. The general design of the fast and slow extraction systems and simulation results are discussed in this paper.

  4. Fast-extraction modulators for Los Alamos Scientific LaboratorY Proton Storage Ring

    International Nuclear Information System (INIS)

    Nunnally, W.C.; Hudgings, D.W.; Sarjeant, W.J.

    1980-01-01

    The development of a short-bunch mode fast-extraction modulator for the LASL proton storage ring has made necessary the design and development of a resonant transformer charging circuit and the design of a new FIB line circuit to provide bipolar pulse outputs with low prepulse, postpulse, and an optimum high-voltage switch environments. The systems are now being developed to operate reliably at the high-average powers required. The short-bunch mode fast-extraction modulator prototype is presently operating. The initial construction of the long-bunch mode fast-extraction modulator prototype is under way, with results expected within the year

  5. The Septum Magnet System of the New Fast Extraction Channel of the SPS at CERN

    CERN Document Server

    Balhan, B; Rizzo, A; Weterings, W

    2004-01-01

    In the Long Straight Section LSS4 of the Super Proton Synchrotron (SPS) at CERN, a new fast extraction system has been installed in order to extract the beam to ring 2 of the Large Hadron Collider (LHC) and the CERN Neutrino to Gran Sasso facility (CNGS). The system consists of horizontal closed orbit bumper magnets, extraction kicker magnets, enlarged aperture quadrupoles and six conventional DC electromagnetic septum magnets (MSE). A protection element (TPSG) has been placed immediately upstream of the first septum coil. The septum magnets and TPSG are mounted on a single mobile retractable support girder. The MSE septa are connected by a so-called plug-in system to a rigid water-cooled bus-bar, powered by water-cooled cables. The whole system is kept at the required vacuum pressure by ion pumps attached to separate pumping modules. In this note we present the design features and parameters of the MSE septum magnets, describe the function of the related main equipment elements, briefly report on the control...

  6. Quartz fast component opticallystimulated luminescence: Towards routine extraction for dating applications

    International Nuclear Information System (INIS)

    Shen, Zhixiong; Lang, Andreas

    2016-01-01

    Using an uncontaminated fast component is a key for improving the reliability of quartz OSL dating for many deposits. So far no approach to extract the fast component of quartz OSL has routinely been adopted for dating practice. Key challenges for extracting fast components are (1) the difficulty of finding a unique solution in curve-fitting deconvolution of OSL decay curves and (2) the relatively poor dating precision when using experimental fast component extraction. Here, a simple mathematic solution for fast component extraction is presented that is not relying on curve-fitting deconvolution and can easily be adopted into routine dating practices. By using specifically selected data points from smoothed OSL decay curves, the precision of equivalent doses calculated using the extracted fast component can be improved over equivalent doses calculated using bulk OSL. The fast component extraction is tested on a group of age-constrained samples containing both insufficiently bleached and sufficiently bleached deposits. Fast component OSL ages are as accurate as bulk OSL ages for the sufficiently bleached deposits, but more accurate for samples where bulk OSL is affected by insufficient bleaching. We also demonstrate how using a curve smoothing procedure can improve dating precision in case of both sufficiently and insufficiently bleached deposits. - Highlights: • A simple mathematical method to extract quartz OSL fast component is presented. • The method can be adopted in D_e calculation programs for routine extraction. • The method leads to an increase in accuracy and precision of D_e. • The method works for relatively dim samples with low signal-to-noise ratios.

  7. The Booster to AGS beam transfer fast kicker systems

    International Nuclear Information System (INIS)

    Zhang, W.; Bunicci, J.; Soukas, A.V.; Zhang, S.Y.

    1992-01-01

    The Brookhaven AGS Booster has a very successful commissioning period in June 1991. The third phase of that commissioning was a beam extraction test. The Booster extraction fast kicker (F3) deflected a 1.2 GeV proton beam from the Booster circulating orbit into the extraction septum aperture, partially down the extraction line to a temporary beam stop. Now, the Booster is committed to the AGS operations program for both heavy ion and proton beams. Thus, the Booster extraction and the corresponding AGS injection systems must operate routinely up to a pulse repetition frequency of 7.5 Hertz, and up to a beam energy of 1.5 Gev. The injection fast kicker is located in the A5 section of the AGS ring and is used to deflect the proton or heavy ion beam into its final AGS closed orbit. A distinctive feature of the AGS injection fast kicker modulators is the tail-bitting function required for proton beam injection. This enables the system to produce a fast current fall time to go along with the high current pulse amplitude with a fast rise time. The AGS injection fast kicker system has three pulse modulators, and each modulator consists of two thyratrons. The main PFN thyratrons switch on the current, and the tail bitting thyratrons are used to force the magnet current to decrease rapidly. Two digital pulse delay generators are used to align the main thyratrons and the tail bitting thyratrons respectively. The system has been tested and installed. The final commissioning of the Booster to AGS beam transfer line and injection is currently being undertaken. In this article, the system design, realization techniques and performance data will be presented

  8. Considerations on a new fast extraction kicker concept for SPS

    CERN Document Server

    Barnes, M

    2010-01-01

    An alternative extraction kicker concept is investigated for the SPS, based on open C-type kickers and a fast-bumper system. The beam is moved into the kicker gap some tens of ms before extraction. The concept is illustrated in detail with the LSS4 extraction from the SPS – very similar parameters and considerations apply to LSS6. A similar concept could also be conceived for injection but is more difficult due to the larger beam size. The technical issues are presented and the potential impact on the machine impedance outlined.

  9. Non-local Fast Extraction from the CERN SPS at 100 and 440 GeV

    CERN Document Server

    Velotti, F M; Bartmann, W; Carlier, E; Cornelis, K; Efthymiopoulos, I; Goddard, B; Jensen, L K; Kain, V; Kowalska, M; Mertens, V; Steerenberg, R

    2013-01-01

    The Long Straight Section 2 (LSS2) of the CERN SPS is connected with the North Area (NA), to which the beam to date has always been extracted using a resonant extraction technique. For new proposed short- and long-baseline neutrino experiments, a fast single turn extraction to this experimental area is required. As there are no kickers in LSS2, and the integration of any new kickers with the existing electrostatic septum would be problematic, a solution has been developed to fast extract the beam using non-local extraction with other SPS kickers. Two different kicker systems have been used, the injection kicker in LSS1 and the stronger extraction kicker in LSS6 to extract 100 and 440 GeV beam, respectively. For both solutions a large emittance beam was extracted after 5 or 9 full betatron periods. The concept and simulation details are presented with the analysis of the aperture and beam loss considerations and experimental results collected during a series of beam tests.

  10. Relationship Between Wood Color Parameters Measured by the CIELab System and Extractive and Phenol Content in Acacia mangium and Vochysia guatemalensis from Fast-Growth Plantations

    Directory of Open Access Journals (Sweden)

    Carolina Tenorio

    2012-03-01

    Full Text Available The heterogeneity of color distribution between sapwood and heartwood limits the market for wood from fast-growth plantations of tropical species. Wood color is associated with wood extractives contents. This study presents the relationship between wood color parameters measured by the CIELab color system and total amount of extractives and phenolic-type extractives in ethanol-toluene and hot water extracts of wood from two fast-growth plantation species. The results demonstrated that the difference in sapwood and hardwood color in Vochysia guatemalensis and Acacia mangium is caused by lower concentrations of extractives in sapwood of both species. Additionally, variations in total extractive and phenolic content have different effects on the color parameters (L*, a* and b* of both species studied. In Vochysia guatemalensis wood, parameter L* decreases as total extractive and phenolic content increases; however, parameter a* increases as the content of extractives and phenols increases. In Acacia mangium, the amount of phenols showed no relationship with the color parameters. The ethanol-toluene total extractive content, however, shows a relationship with several color parameters. An increase in the content of total extractives in water and ethanol-toluene increases parameter a*, but decreases parameter L*.

  11. Design Considerations of Fast Kicker Systems for High Intensity Proton Accelerators

    International Nuclear Information System (INIS)

    Zhang, W.; Sandberg, J.; Parson, W.M.; Walstrom, P.; Murray, M.M.; Cook, E.; Hartouni, E.

    2001-01-01

    In this paper, we discuss the specific issues related to the design of the Fast Kicker Systems for high intensity proton accelerators. To address these issues in the preliminary design stage can be critical since the fast kicker systems affect the machine lattice structure and overall design parameters. Main topics include system architecture, design strategy, beam current coupling, grounding, end user cost vs. system cost, reliability, redundancy and flexibility. Operating experience with the Alternating Gradient Synchrotron injection and extraction kicker systems at Brookhaven National Laboratory and their future upgrade is presented. Additionally, new conceptual designs of the extraction kicker for the Spallation Neutron Source at Oak Ridge and the Advanced Hydrotest Facility at Los Alamos are discussed

  12. Beam extraction control systems of the fast-cycling synchrotron

    International Nuclear Information System (INIS)

    Toumanian, A.; Zapolski, N.; Nickogosian, V.; Ananian, A.; Kazarian, A.; Khoetsian, M.; Agababian, A.; Matevosian, A.

    1992-01-01

    A compact system controlling the extraction of different beams (gamma, electron, synchrotron radiation) in single and simultaneous operation modes at high electromagnetic disturbances level based on using one computer of IBM PC/AT type is described. (author)

  13. Fast Extraction Kicker for the Accelerator Test Facility

    International Nuclear Information System (INIS)

    De Santis, Stefano; Urakawa, Junji; Naito, Takashi

    2007-01-01

    We present the results of a study for the design of a fast extraction kicker to be installed in the Accelerator Test Facility ring at KEK. This activity is carried on in the framework of the ATF2 project, which will be built on the KEK Tsukuba campus as an extension of the existing ATF, taking advantage of the worlds smallest normalized emittance achieved there. ATF2's primary goal is to operate as a test facility and establish the hardware and beam handling technologies envisaged for the International Linear Collider. In particular, the fast extraction kicker object of the present paper is an important component of the ILC damping rings, since its rise and fall time define the minimum distance between bunches and ultimately the damping rings length itself. Building on the initial results presented at EPAC '06, we report on the present status of the kicker design and define the minimum characteristics for pulsers and other subsystems. In addition to the original scheme with multiple stripline modules producing a total deflection of 5 mrad, we also investigated a scheme with a single kicker module for a reduced deflection of 1 mrad placed inside a closed orbit bump, which takes the electron closer to the extraction septum

  14. A FAST AND ROBUST ALGORITHM FOR ROAD EDGES EXTRACTION FROM LIDAR DATA

    Directory of Open Access Journals (Sweden)

    K. Qiu

    2016-06-01

    Full Text Available Fast mapping of roads plays an important role in many geospatial applications, such as infrastructure planning, traffic monitoring, and driver assistance. How to extract various road edges fast and robustly is a challenging task. In this paper, we present a fast and robust algorithm for the automatic road edges extraction from terrestrial mobile LiDAR data. The algorithm is based on a key observation: most roads around edges have difference in elevation and road edges with pavement are seen in two different planes. In our algorithm, we firstly extract a rough plane based on RANSAC algorithm, and then multiple refined planes which only contains pavement are extracted from the rough plane. The road edges are extracted based on these refined planes. In practice, there is a serious problem that the rough and refined planes usually extracted badly due to rough roads and different density of point cloud. To eliminate the influence of rough roads, the technology which is similar with the difference of DSM (digital surface model and DTM (digital terrain model is used, and we also propose a method which adjust the point clouds to a similar density to eliminate the influence of different density. Experiments show the validities of the proposed method with multiple datasets (e.g. urban road, highway, and some rural road. We use the same parameters through the experiments and our algorithm can achieve real-time processing speeds.

  15. Design of fast kickers for the ISABELLE beam abort system

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Montemurro, P.A.; Baron, J.

    1981-01-01

    The ISA beam abort (extraction) system must be highly efficient, in the sense of producing minimum beam loss, and reliable to prevent serious damage to accelerator components by the circulating high-energy beams. Since the stored beams will be debunched, the low-loss requirement can be met only with ultra-thin extraction septa and/or fast-acting kickers. This paper examines the design of the ISA extraction kickers subject to a set of extraction channel constraints and a given maximum working voltage. Expressions are derived for determining system parameters for both a lumped parameter magnet and a delay-line magnet. Using these relationships, design parameters are worked out for several possible system configurations. The paper also describes the construction of a full-scale prototype module of the kicker and summarizes the preliminary test results obtained with the module

  16. Synchronous timing of multi-energy fast beam extraction during a single AGS cycle

    International Nuclear Information System (INIS)

    Gabusi, J.; Naase, S.

    1985-01-01

    Synchronous triggering of fast beams is required because the field of Kicker Magnets must rise within the open space between one beam bunch and the next. Within the Brookhaven AGS, Fast Extracted Beam (FEB) triggering combines nominal timing, based on beam energy with bunch-to-bunch synchronization, based on the accelerating rf waveform. During beam acceleration, a single bunch is extracted at 22 GeV/c and within the same AGS cycle, the remaining eleven bunches are extracted at 28.4 GeV/c. When the single bunch is extracted, a ''hole'', which is left in the remaining circulating beam, can appear in random locations within the second extraction during successive AGS cycles. To overcome this problem, a synchronous rf/12 counting scheme and logic circuitry are used to keep track of the bunch positions relative to each other, and to place the ''hole'' in any desired location within the second extraction. The rf/12 signal is used also to synchronize experimenters triggers

  17. A new license plate extraction framework based on fast mean shift

    Science.gov (United States)

    Pan, Luning; Li, Shuguang

    2010-08-01

    License plate extraction is considered to be the most crucial step of Automatic license plate recognition (ALPR) system. In this paper, a region-based license plate hybrid detection method is proposed to solve practical problems under complex background in which existing large quantity of disturbing information. In this method, coarse license plate location is carried out firstly to get the head part of a vehicle. Then a new Fast Mean Shift method based on random sampling of Kernel Density Estimate (KDE) is adopted to segment the color vehicle images, in order to get candidate license plate regions. The remarkable speed-up it brings makes Mean Shift segmentation more suitable for this application. Feature extraction and classification is used to accurately separate license plate from other candidate regions. At last, tilted license plate regulation is used for future recognition steps.

  18. Blind Extraction of Chaotic Signals by Using the Fast Independent Component Analysis Algorithm

    International Nuclear Information System (INIS)

    Hong-Bin, Chen; Jiu-Chao, Feng; Yong, Fang

    2008-01-01

    We report the results of using the fast independent component analysis (FastICA) algorithm to realize blind extraction of chaotic signals. Two cases are taken into consideration: namely, the mixture is noiseless or contaminated by noise. Pre-whitening is employed to reduce the effect of noise before using the FastICA algorithm. The correlation coefficient criterion is adopted to evaluate the performance, and the success rate is defined as a new criterion to indicate the performance with respect to noise or different mixing matrices. Simulation results show that the FastICA algorithm can extract the chaotic signals effectively. The impact of noise, the length of a signal frame, the number of sources and the number of observed mixtures on the performance is investigated in detail. It is also shown that regarding a noise as an independent source is not always correct

  19. Determination of Terpenoid Content in Pine by Organic Solvent Extraction and Fast-GC Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Harman-Ware, Anne E., E-mail: anne.ware@nrel.gov; Sykes, Robert [National Bioenergy Center, National Renewable Energy Laboratory, Golden, CO (United States); Peter, Gary F. [School of Forest Resources and Conservation, University of Florida, Gainesville, FL (United States); Davis, Mark [National Bioenergy Center, National Renewable Energy Laboratory, Golden, CO (United States)

    2016-01-25

    Terpenoids, naturally occurring compounds derived from isoprene units present in pine oleoresin, are a valuable source of chemicals used in solvents, fragrances, flavors, and have shown potential use as a biofuel. This paper describes a method to extract and analyze the terpenoids present in loblolly pine saplings and pine lighter wood. Various extraction solvents were tested over different times and temperatures. Samples were analyzed by pyrolysis-molecular beam mass spectrometry before and after extractions to monitor the extraction efficiency. The pyrolysis studies indicated that the optimal extraction method used a 1:1 hexane/acetone solvent system at 22°C for 1 h. Extracts from the hexane/acetone experiments were analyzed using a low thermal mass modular accelerated column heater for fast-GC/FID analysis. The most abundant terpenoids from the pine samples were quantified, using standard curves, and included the monoterpenes, α- and β-pinene, camphene, and δ-carene. Sesquiterpenes analyzed included caryophyllene, humulene, and α-bisabolene. Diterpenoid resin acids were quantified in derivatized extractions, including pimaric, isopimaric, levopimaric, palustric, dehydroabietic, abietic, and neoabietic acids.

  20. Determination of Terpenoid Content in Pine by Organic Solvent Extraction and Fast-GC Analysis

    International Nuclear Information System (INIS)

    Harman-Ware, Anne E.; Sykes, Robert; Peter, Gary F.; Davis, Mark

    2016-01-01

    Terpenoids, naturally occurring compounds derived from isoprene units present in pine oleoresin, are a valuable source of chemicals used in solvents, fragrances, flavors, and have shown potential use as a biofuel. This paper describes a method to extract and analyze the terpenoids present in loblolly pine saplings and pine lighter wood. Various extraction solvents were tested over different times and temperatures. Samples were analyzed by pyrolysis-molecular beam mass spectrometry before and after extractions to monitor the extraction efficiency. The pyrolysis studies indicated that the optimal extraction method used a 1:1 hexane/acetone solvent system at 22°C for 1 h. Extracts from the hexane/acetone experiments were analyzed using a low thermal mass modular accelerated column heater for fast-GC/FID analysis. The most abundant terpenoids from the pine samples were quantified, using standard curves, and included the monoterpenes, α- and β-pinene, camphene, and δ-carene. Sesquiterpenes analyzed included caryophyllene, humulene, and α-bisabolene. Diterpenoid resin acids were quantified in derivatized extractions, including pimaric, isopimaric, levopimaric, palustric, dehydroabietic, abietic, and neoabietic acids.

  1. Tevatron extraction microcomputer

    International Nuclear Information System (INIS)

    Chapman, L.; Finley, D.A.; Harrison, M.; Merz, W.

    1985-06-01

    Extraction in the Fermilab Tevatron is controlled by a multi-processor Multibus microcomputer system called QXR (Quad eXtraction Regulator). QXR monitors several analog beam signals and controls three sets of power supplies: the ''bucker'' and ''pulse'' magnets at a rate of 5760 Hz, and the ''QXR'' magnets at 720 Hz. QXR supports multiple slow spills (up to a total of 35 seconds) with multiple fast pulses intermixed. It linearizes the slow spill and bucks out the high frequency components. Fast extraction is done by outputting a variable pulse waveform. Closed loop learning techniques are used to improve performance from cycle to cycle for both slow and fast extraction. The system is connected to the Tevatron clock system so that it can track the machine cycle. QXR is also connected to the rest of the Fermilab control system, ACNET. Through ACNET, human operators and central computers can monitor and control extraction through communications with QXR. The controls hardware and software both employ some standard and some specialized components. This paper gives an overview of QXR as a control system; another paper summarizes performance

  2. A fast-slow logic system

    International Nuclear Information System (INIS)

    Kawashima, Hideo.

    1977-01-01

    A fast-slow logic system has been made for use in multi-detector experiments in nuclear physics such as particle-gamma and particle-particle coincidence experiments. The system consists of a fast logic system and a slow logic system. The fast logic system has a function of fast coincidences and provides timing signals for the slow logic system. The slow logic system has a function of slow coincidences and a routing control of input analog signals to the ADCs. (auth.)

  3. Tevatron extraction microcomputer

    International Nuclear Information System (INIS)

    Chapman, L.; Finley, D.A.; Harrison, M.; Merz, W.; Batavia, IL)

    1985-01-01

    Extraction in the Fermilab Tevatron is controlled by a multi-processor Multibus microcomputer system called QXR (Quad eXtraction Regulator). QXR monitors several analog beam signals and controls three sets of power supplies: the ''bucker'' and ''pulse'' magnets at a rate of 5760 Hz, and the ''QXR'' magnets at 720 Hz. QXR supports multiple slow spills (up to a total of 35 seconds) with multiple fast pulses intermixed. It linearizes the slow spill and bucks out the high frequency components. Fast extraction is done by outputting a variable pulse waveform. Closed loop learning techniques are used to improve performance from cycle to cycle for both slow and fast extraction. The system is connected to the Tevatron clock system so that it can track the machine cycle. QXR is also connected to the rest of the Fermilab control system, ACNET. Through ACNET, human operators and central computers can monitor and control extraction through communications with QXR. The controls hardware and software both employ some standard and some specialized components. This paper gives an overview of QXR as a control system; another paper (1) summarizes performance

  4. Feature extraction from mammographic images using fast marching methods

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.

    2002-01-01

    Features extraction from medical images represents a fundamental step for shape recognition and diagnostic support. The present work faces the problem of the detection of large features, such as massive lesions and organ contours, from mammographic images. The regions of interest are often characterized by an average grayness intensity that is different from the surrounding. In most cases, however, the desired features cannot be extracted by simple gray level thresholding, because of image noise and non-uniform density of the surrounding tissue. In this work, edge detection is achieved through the fast marching method (Level Set Methods and Fast Marching Methods, Cambridge University Press, Cambridge, 1999), which is based on the theory of interface evolution. Starting from a seed point in the shape of interest, a front is generated which evolves according to an appropriate speed function. Such function is expressed in terms of geometric properties of the evolving interface and of image properties, and should become zero when the front reaches the desired boundary. Some examples of application of such method to mammographic images from the CALMA database (Nucl. Instr. and Meth. A 460 (2001) 107) are presented here and discussed

  5. COSMO-RS-based extractant screening for phenol extraction as model system

    NARCIS (Netherlands)

    Burghoff, B.; Goetheer, E.L.V.; Haan, A.B. de

    2008-01-01

    The focus of this investigation is the development of a fast and reliable extractant screening approach. Phenol extraction is selected as the model process. A quantum chemical conductor-like screening model for real solvents (COSMO-RS) is combined with molecular design considerations. For this

  6. Cyclotrons with fast variable and/or multiple energy extraction

    Directory of Open Access Journals (Sweden)

    C. Baumgarten

    2013-10-01

    Full Text Available We discuss the possibility in principle of stripping extraction in combination with reverse bends in isochronous separate-sector cyclotrons (and/or fixed field alternating gradient accelerators. If one uses reverse bends between the sectors (instead of or in combination with drifts and places stripper foils at the sector exit edges, the stripped beam has a reduced bending radius and it should be able to leave the cyclotron within the range of the valley—even if the beam is stripped at less than full energy. We are especially interested in stripping of H_{2}^{+}, as it doubles the charge to mass ratio of the ions. However the method could be applied to other ions or ionized molecules as well. For the production of proton beams by stripping extraction of an H_{2}^{+} beam, we discuss possible designs for three types of machines: First, a low-energy cyclotron for the simultaneous production of several beams at multiple energies—for instance 15, 30, and 70 MeV—thus allowing beam delivery on several isotope production targets. In this case it can be an advantage to have a strong energy dependence of the direction of the extracted beam. Second, we consider a fast variable-energy proton machine for cancer therapy that should allow extraction (of the complete beam at all energies in the range of about 70 MeV to about 250 MeV into the same beam line. Third, we consider a high-intensity high-energy machine, where the main design goals are extraction with low losses, low activation of components, and high reliability. Especially if such a machine is considered for an accelerator driven system (ADS, this extraction mechanism has advantages: Beam trips by the failure of electrostatic elements could be avoided and the turn separation would be less critical, which allows operation at lower main cavity voltages. This would in turn reduce the number of rf trips. The price that has to be paid for these advantages is an increase in size and/or field

  7. Developmental validation of the PowerPlex(®) ESI 16/17 Fast and PowerPlex(®) ESX 16/17 Fast Systems.

    Science.gov (United States)

    McLaren, Robert S; Bourdeau-Heller, Jeanne; Patel, Jaynish; Thompson, Jonelle M; Pagram, Jenny; Loake, Thomas; Beesley, David; Pirttimaa, Markus; Hill, Carolyn R; Duewer, David L; Kline, Margaret C; Butler, John M; Storts, Douglas R

    2014-11-01

    The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. A High-Speed Vision-Based Sensor for Dynamic Vibration Analysis Using Fast Motion Extraction Algorithms

    Directory of Open Access Journals (Sweden)

    Dashan Zhang

    2016-04-01

    Full Text Available The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.

  9. Contribution to the study of liquid-liquid extraction dynamics in the case of fast transfers. Extractions of uranium, plutonium and neptunium in a laboratory centrifugal extractor

    International Nuclear Information System (INIS)

    Bergeonneau, Philippe

    1978-01-01

    The liquid-liquid extraction (also named solvent-based extraction) is a very important technique for the reprocessing of irradiated nuclear fuels. This research thesis is based on the use of a laboratory centrifugal extractor which allows interesting conditions to be achieved: fast transfer due to an intense solution mixing, very short duration of contact between solutions. Thus, after a report of a bibliographical study on chemical mechanisms of extraction, on the composition of extracted species, on extraction kinetics, and on centrifugal extractors, this thesis reports the design, fabrication and use of a centrifugal extractor: presentation of fundamental principles, description and characteristics (materials, hydrodynamic operation test and problems, prototype). It reports studies of fast transfer kinetics: mathematical processing, result interpretation, results and discussions of extraction kinetics for nitric acid, uranium VI and IV, plutonium IV, neptunium IV, and comparison of the different extraction kinetics

  10. A fast, simple and green method for the extraction of carbamate pesticides from rice by microwave assisted steam extraction coupled with solid phase extraction.

    Science.gov (United States)

    Song, Weitao; Zhang, Yiqun; Li, Guijie; Chen, Haiyan; Wang, Hui; Zhao, Qi; He, Dong; Zhao, Chun; Ding, Lan

    2014-01-15

    This paper presented a fast, simple and green sample pretreatment method for the extraction of 8 carbamate pesticides in rice. The carbamate pesticides were extracted by microwave assisted water steam extraction method, and the extract obtained was immediately applied on a C18 solid phase extraction cartridge for clean-up and concentration. The eluate containing target compounds was finally analysed by high performance liquid chromatography with mass spectrometry. The parameters affecting extraction efficiency were investigated and optimised. The limits of detection ranging from 1.1 to 4.2ngg(-1) were obtained. The recoveries of 8 carbamate pesticides ranged from 66% to 117% at three spiked levels, and the inter- and intra-day relative standard deviation values were less than 9.1%. Compared with traditional methods, the proposed method cost less extraction time and organic solvent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The fast extraction kicker power supply for the main ring of J-PARC

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, Kunio, E-mail: kunio.koseki@kek.jp

    2013-11-21

    An effect induced by parasitic inductance in a pulsed power supply for a fast extraction kicker was studied. The parasitic inductance in high voltage capacitors for a low impedance pulse forming network disturbs a sharp rise of an excitation current. A high voltage capacitor with a coaxial structure to minimize the parasitic inductance is proposed. The effectiveness was confirmed experimentally. An impedance mismatch by a leakage inductance of a pulse transformer in a transmission line was studied. The effect is serious at the flat-top period of the excitation current. By introducing a compensation circuit, which is composed by a capacitor and a resistor, impedance matching was established. The pulsed power supply for the fast extraction kicker was operated at a charging voltage of 30 kV. A required rise time of less than 1.1 μs was achieved. The flatness was also confirmed to be in an acceptable value of less than 1%. -- Highlights: ●An effect by parasitic inductance of the energy storage capacitor of the PFN was studied. ●A faster rise time was achieved by introducing a coaxial structure for the PFN capacitor. ●An impedance mismatch by a leakage inductance of a pulse transformer was studied. ●Serious deterioration of the pulsed waveform was cured by a compensation circuit. ●The pulsed power supply for the fast extraction kicker was developed and operated successfully.

  12. Uranium, Plutonium and Neptunium Co-recovery with Irradiated Fast Reactor MOX Fuel by Single Cycle Extraction Process

    Energy Technology Data Exchange (ETDEWEB)

    Masaumi Nakahara; Yuichi Sano; Kazunori Nomura; Tadahiro Washiya; Jun Komaki [Japan Atomic Energy Agency, 4-33 Muramatsu, Tokai-mura, Naka-gun, Ibaraki, 319-1194 (Japan)

    2008-07-01

    The behavior of Np in single cycle extraction processes using tri-n-butylphosphate (TBP) as an extractant for U, Pu and Np co-recovery was investigated as a part of NEXT (New Extraction System for Transuranium) process. Two approaches for Np co-recovery with U and Pu were carried out with irradiated MOX fuel from fast reactor 'JOYO'; one was the counter current experiment using a feed solution with a high HNO{sub 3} concentration and the other used a scrubbing solution with a high HNO{sub 3} concentration. Experimental results showed that the leakage of Np to the raffinate were 0.986 % and 5.96 % under the condition of high HNO{sub 3} concentration in the feed solution and scrubbing solution, respectively. The simulation results based on these experiments indicated that most of Np could be extracted and co-recovered with U and Pu, just by increasing HNO{sub 3} concentrations in the feed and scrubbing solution on the single cycle extraction process. (authors)

  13. Role of ethanol leaf extracts of Ficus glumosa on fasting blood ...

    African Journals Online (AJOL)

    Normal saline 5ml/kg, 100mg/kg, 200mg/kg and 400mg/kg of Ficus glumosa ethanol leaves extract respectively via ip while Group V received insulin 6 iu/kg. Fasting blood sugar levels were measured at one day intervals for 7 days. Rats were sacrifice for the Serum liver enzymes and liver tissue for th analysis on the 7 day.

  14. FAST: An advanced code system for fast reactor transient analysis

    International Nuclear Information System (INIS)

    Mikityuk, Konstantin; Pelloni, Sandro; Coddington, Paul; Bubelis, Evaldas; Chawla, Rakesh

    2005-01-01

    One of the main goals of the FAST project at PSI is to establish a unique analytical code capability for the core and safety analysis of advanced critical (and sub-critical) fast-spectrum systems for a wide range of different coolants. Both static and transient core physics, as well as the behaviour and safety of the power plant as a whole, are studied. The paper discusses the structure of the code system, including the organisation of the interfaces and data exchange. Examples of validation and application of the individual programs, as well as of the complete code system, are provided using studies carried out within the context of designs for experimental accelerator-driven, fast-spectrum systems

  15. System design considerations for fast-neutron interrogation systems

    International Nuclear Information System (INIS)

    Micklich, B.J.; Curry, B.P.; Fink, C.L.; Smith, D.L.; Yule, T.J.

    1993-01-01

    Nonintrusive interrogation techniques that employ fast neutrons are of interest because of their sensitivity to light elements such as carbon, nitrogen, and oxygen. The primary requirement of a fast-neutron inspection system is to determine the value of atomic densities, or their ratios, over a volumetric grid superimposed on the object being interrogated. There are a wide variety of fast-neutron techniques that can provide this information. The differences between the various nuclear systems can be considered in light of the trade-offs relative to the performance requirements for each system's components. Given a set of performance criteria, the operational requirements of the proposed nuclear systems may also differ. For instance, resolution standards will drive scanning times and tomographic requirements, both of which vary for the different approaches. We are modelling a number of the fast-neutron interrogation techniques currently under consideration, to include Fast Neutron Transmission Spectroscopy (FNTS), Pulsed Fast Neutron Analysis (PFNA), and its variant, 14-MeV Associated Particle Imaging (API). The goals of this effort are to determine the component requirements for each technique, identify trade-offs that system performance standards impose upon those component requirements, and assess the relative advantages and disadvantages of the different approaches. In determining the component requirements, we will consider how they are driven by system performance standards, such as image resolution, scanning time, and statistical uncertainty. In considering the trade-offs between system components, we concentrate primarily on those which are common to all approaches, for example: source characteristics versus detector array requirements. We will then use the analysis to propose some figures-of-merit that enable performance comparisons between the various fast-neutron systems under consideration. The status of this ongoing effort is presented

  16. Conceptual design study on advanced aqueous reprocessing system for fast reactor fuel cycle

    International Nuclear Information System (INIS)

    Takata, Takeshi; Koma, Yoshikazu; Sato, Koji; Kamiya, Masayoshi; Shibata, Atsuhiro; Nomura, Kazunori; Ogino, Hideki; Koyama, Tomozo; Aose, Shin-ichi

    2003-01-01

    As a feasibility study on commercialized fast reactor cycle system, a conceptual design study is being progressed for the aqueous and pyrochemical processes from the viewpoint of economical competitiveness, efficient utilization of resources, decreasing environmental impact and proliferation resistance in Japan Nuclear Cycle Development Institute (JNC). In order to meet above-mentioned requirements, the survey on a range of reprocessing technologies and the evaluation of conceptual plant designs against targets for the future fast reactor cycle system have been implemented as the fist phase of the feasibility study. For an aqueous reprocessing process, modification of the conventional PUREX process (a solvent extraction process with purification of U/Pu, with nor recovery of minor actinides (MA)) and investigation of alternatives for the PUREX process has been carried out and design study of advanced aqueous reprocessing system and its alternatives has been conducted. The conceptual design of the advanced aqueous reprocessing system has been updated and evaluated by the latest R and D results of the key technologies such as crystallization, single-cycle extraction, centrifugal contactors, recovery of Am/Cm and waste processing. In this paper, the outline of the design study and the current status of development for advanced aqueous reprocessing system, NEXT process, are mentioned. (author)

  17. Simulation study on control of spill structure of slow extracted beam from a medical synchrotron with feed-forward and feedback using a fast quadruple magnet and RF-knockout system

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, Ryo; Nakanishi, Tetsuya, E-mail: nakanishi.tetsuya@nihon-u.ac.jp

    2017-02-21

    A feedback control of the spill structure for the slow beam extraction from the medical synchrotron using a fast quadruple and radio frequency (RF)-knockout (QAR method) is studied to obtain the designed spill structure. In addition the feed-forward control is used so that the feedback control is performed effectively. In this extraction method, the spill of several ms are extracted continuously with an interval time of less than 1 ms. Beam simulation showed that a flat spill structure was effectively obtained with feed-forward and feedback control system as well as a step-wise structure which is useful for the shortening of an irradiation time in a spot scanning operation. The effect of current ripples from main quadruple magnet's power supplies could be also reduced with the feedback control application.

  18. Information extraction system

    Science.gov (United States)

    Lemmond, Tracy D; Hanley, William G; Guensche, Joseph Wendell; Perry, Nathan C; Nitao, John J; Kidwell, Paul Brandon; Boakye, Kofi Agyeman; Glaser, Ron E; Prenger, Ryan James

    2014-05-13

    An information extraction system and methods of operating the system are provided. In particular, an information extraction system for performing meta-extraction of named entities of people, organizations, and locations as well as relationships and events from text documents are described herein.

  19. Role of ethanol leaf extracts of Ficus Glumosa on fasting blood ...

    African Journals Online (AJOL)

    Normal saline 5ml/kg, 100mg/kg, 200mg/kg and 400mg/kg of Ficus glumosa ethanol leaves extract respectively via ip while Group V received insulin 6 iu/kg. Fasting blood sugar levels were measured at one day intervals for 7 days. Rats were sacrifice for the Serum liver enzymes and liver the tissue for analysis on the 7 day ...

  20. Metabolic profiles and bile acid extraction rate in the liver of cows with fasting-induced hepatic lipidosis.

    Science.gov (United States)

    Mohamed, T; Oikawa, S; Iwasaki, Y; Mizunuma, Y; Takehana, K; Endoh, D; Kurosawa, T; Sato, H

    2004-04-01

    This study was designed to monitor lipid profile in the portal and hepatic blood of cows with fasting-induced hepatic lipidosis, and to compare the results with those in the jugular blood. The work was also carried out to investigate bile acid (BA) in these vessels, and further to investigate BA extraction rate in the liver. Five cows were equipped with catheters in the portal, hepatic and jugular veins (day 0), fasted for 4 days (day 1-day 4) and then refed (day 5-day 11). Before morning feeding, blood was sampled before, during and after fasting from the catheterized vessels. In the portal blood, the concentration of non-esterified fatty acids (NEFA) showed a progressive increase and at day 5 there was an approximate twofold rise. Increased NEFA concentrations were also found similarly in the other two veins. At day 5, beta-hydroxybutyrate (BHBA) in the portal, hepatic and jugular blood rose to 197, 190 and 186% of the pre-fasting value, respectively. However, the concentrations of NEFA and BHBA in the three veins gradually returned to pre-fasting concentration during the refeeding period. Compared with the pre-fasting value at day 0, the content of liver triglyceride (TG) increased significantly at day 5 (P hepatic extraction rate of BA dropped from 3.1 times pre-fasting to 2.2 times during fasting. There were no significant differences in the concentrations of glucose, TG, total cholesterol, cholesterol esters, free cholesterol and phospholipids. The results of the current study show that metabolic alterations occur in the portal, hepatic and jugular veins during induction of hepatic lipidosis in cows, and mostly metabolites, with exception of BA concentration, run parallel. The decreased BA extraction rate in the liver of fasted cows was considered to reflect hepatic cell impairment caused by TG accumulation. Hopefully, the findings, at least in part, contribute to the explanation of the pathophysiology of hepatic lipidosis in dairy cows.

  1. Integrated Solid-Phase Extraction-Capillary Liquid Chromatography (speLC) Interfaced to ESI-MS/MS for Fast Characterization and Quantification of Protein and Proteomes

    DEFF Research Database (Denmark)

    Falkenby, Lasse Gaarde; Such-Sanmartín, Gerard; Larsen, Martin Røssel

    2014-01-01

    min speLC-MS/MS experiment. Analysis by selected reaction monitoring by speLC-SRM-MS/MS of distinct peptides derived from the blood proteins IGF1, IGF2, IBP2, and IBP3 demonstrated protein quantification with CV values below 10% across 96 replicates. The speLC-MS/MS system is ideally suited for fast......The high peptide sequencing speed provided by modern hybrid tandem mass spectrometers enables the utilization of fast liquid chromatographic (LC) separation techniques. We present a robust solid-phase extraction/capillary LC system (speLC) for 5-10 min separation of semicomplex peptide mixtures...

  2. Activity assay of mangosteen (Garcinia mangostana L.) pericarp extract for decreasing fasting blood cholesterol level and lipid peroxidation in type-2 diabetic mice

    Science.gov (United States)

    Husen, Saikhu Akhmad; Winarni, Dwi; Khaleyla, Firas; Kalqutny, Septian Hary; Ansori, Arif Nur Muhammad

    2017-09-01

    This study aimed to explore the activity of pericarp extract of mangosteen (Garcinia mangostana L.). Mangosteen pericarp contains various active compounds which are beneficial for human health. In-vivo antioxidant assay of pericarp extract was carried out using 3-4 month male mice of strain BALB/c weighed 30-40 g. The mice were divided into two groups: normal control (KN) group and STZ-induced diabetic group. STZ induction was performed using multiple low-dose method 30 mg/kg body weight treated daily for five consecutive days. Diabetic group was separated into two subgroups: diabetic control (KD), metformin control (KM), and crude extract treatment subgroups. The fasting blood glucose and the cholesterol level were measured before and after lard treatment, we also did it on the first, seventh, and fourteenth day of mangosteen pericarp crude extract treatment. The mice were treated with mangosteen pericarp crude extract for 14 days. The MDA level of the fasting blood serum was measured. The body weight and fasting blood cholesterol level before and after lard treatment were analyzed by t-test, whereas, the fasting blood cholesterol and the MDA level were analyzed using one-way variant analysis continued with Duncan test. The correlation between the increasing body weight and the fasting blood cholesterol level was determined by Pearson correlation test. The results of the study showed that the administration of mangosteen pericarp crude extract was able to reduce the fasting blood cholesterol and the malondialdehide level significantly.

  3. Fast decoding algorithms for coded aperture systems

    International Nuclear Information System (INIS)

    Byard, Kevin

    2014-01-01

    Fast decoding algorithms are described for a number of established coded aperture systems. The fast decoding algorithms for all these systems offer significant reductions in the number of calculations required when reconstructing images formed by a coded aperture system and hence require less computation time to produce the images. The algorithms may therefore be of use in applications that require fast image reconstruction, such as near real-time nuclear medicine and location of hazardous radioactive spillage. Experimental tests confirm the efficacy of the fast decoding techniques

  4. Autonomous celestial navigation based on Earth ultraviolet radiance and fast gradient statistic feature extraction

    Science.gov (United States)

    Lu, Shan; Zhang, Hanmo

    2016-01-01

    To meet the requirement of autonomous orbit determination, this paper proposes a fast curve fitting method based on earth ultraviolet features to obtain accurate earth vector direction, in order to achieve the high precision autonomous navigation. Firstly, combining the stable characters of earth ultraviolet radiance and the use of transmission model software of atmospheric radiation, the paper simulates earth ultraviolet radiation model on different time and chooses the proper observation band. Then the fast improved edge extracting method combined Sobel operator and local binary pattern (LBP) is utilized, which can both eliminate noises efficiently and extract earth ultraviolet limb features accurately. And earth's centroid locations on simulated images are estimated via the least square fitting method using part of the limb edges. Taken advantage of the estimated earth vector direction and earth distance, Extended Kalman Filter (EKF) is applied to realize the autonomous navigation finally. Experiment results indicate the proposed method can achieve a sub-pixel earth centroid location estimation and extremely enhance autonomous celestial navigation precision.

  5. Fast pulse beam generation systems for electron accelerators

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1977-01-01

    The fast pulse beam generation system to supply the SLAC storage ring, SPEAR, by the two one nanosecond bunch electron beam pulses is described. Generation of these pulses is accomplished with a combination of a fast pulsed grided gun and a synchronized transverse beam chopper. Fast gun based on spherical cathode-grid assembly has output current up to 2As. Fast pulse amplifier system can handle trains of short pulses with repetition rates up to 40 MHz during the 1.6 μs normal accelerating time. Chopping deflector system consists of a resonant coaxial line with the deflecting plates. The resonator frequency is 39.667 MHz. A schematic diagram of the resonant system is shown. The fast beam pickup system has a one hundred picosecond rise time overrall. Fast beam generation and chopper systems permit to generate almost any short or single bunch beam profile needed for experiments

  6. CONTINOUS EXTRACTED BEAM IN THE AGS FAST EXTERNAL BEAM LINE

    International Nuclear Information System (INIS)

    GLENN, J.W.; TSOUPAS, N.; BROWN, K.A.; BIRYUKOV, V.M.

    2001-01-01

    A method to split off a few percent of the 6 x 10 13 AGS beam delivered to the Slow External Beam (SEB) lines and send it down the Fast External Beam line (FEB) has been developed. The mission is to feed a counter experiment off the FEB that directly measures the neutrino mass using the muon storage ring. The use of normal thin septum splitters would have an excessive loss overhead and been optically difficult. The AGS Slow Extraction uses a third integer resonance with sextuple strength so the resonance width is a few percent of the beam width. This results in a low density tail which will be clipped by a bent crystal and deflected into the FEB channel. This clipping off of the tail should reduce losses in the SEB transport line. Details of modeled orbits, particle distribution and extraction trajectories into and out off the crystal will be given

  7. Development of a SISAK extraction system for chemical studies of element 108, hassium

    International Nuclear Information System (INIS)

    Samadani, F.; Alstad, J.; Bjoernstad, T.; Stavsetra, L.; Omtvedt, J.P.

    2010-01-01

    A liquid-liquid extraction system suitable for studies of chemical properties of Hs (element 108), in the form of HsO 4 , was developed using γ-emitting isotopes of its homologue Os. The system is targeted for the fast on-line extraction system SISAK, which operates in a continuous manner and is suitable for liquid-phase studies of transactinide elements. The distribution of OsO 4 between various dilute NaOH solutions and toluene was studied. Both batch and SISAK on-line experiments were performed to develop an appropriate system. From analysis of the extraction curves equilibrium constants for the formation of the presumed complexes, Na[OsO 4 (OH)] and Na 2 [OsO 4 (OH) 2 ], were obtained: K 1 = (1 ± 0.5) x 10 4 and K 2 = 12 ± 8, respectively. The SISAK system includes a liquid-scintillation detection system for α measurements. Due to quenching effects it is not possible to perform direct measurement of the aqueous phase α's. Therefore, a two-stage extraction method that provides an indirect measurement of the activity in the aqueous phase was developed as part of the proposed system for Hs: Acidification of the raffinate from the first stage result in recovery of OsO 4 , which is highly extractable into toluene. The yield of extraction in the second step, from 0.01 M NaOH solution after acidification with H 2 SO 4 solution, was (90 ± 3)%. (orig.)

  8. Enhanced subject-specific resting-state network detection and extraction with fast fMRI.

    Science.gov (United States)

    Akin, Burak; Lee, Hsu-Lei; Hennig, Jürgen; LeVan, Pierre

    2017-02-01

    Resting-state networks have become an important tool for the study of brain function. An ultra-fast imaging technique that allows to measure brain function, called Magnetic Resonance Encephalography (MREG), achieves an order of magnitude higher temporal resolution than standard echo-planar imaging (EPI). This new sequence helps to correct physiological artifacts and improves the sensitivity of the fMRI analysis. In this study, EPI is compared with MREG in terms of capability to extract resting-state networks. Healthy controls underwent two consecutive resting-state scans, one with EPI and the other with MREG. Subject-level independent component analyses (ICA) were performed separately for each of the two datasets. Using Stanford FIND atlas parcels as network templates, the presence of ICA maps corresponding to each network was quantified in each subject. The number of detected individual networks was significantly higher in the MREG data set than for EPI. Moreover, using short time segments of MREG data, such as 50 seconds, one can still detect and track consistent networks. Fast fMRI thus results in an increased capability to extract distinct functional regions at the individual subject level for the same scan times, and also allow the extraction of consistent networks within shorter time intervals than when using EPI, which is notably relevant for the analysis of dynamic functional connectivity fluctuations. Hum Brain Mapp 38:817-830, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  10. FAST DISCRETE CURVELET TRANSFORM BASED ANISOTROPIC FEATURE EXTRACTION FOR IRIS RECOGNITION

    Directory of Open Access Journals (Sweden)

    Amol D. Rahulkar

    2010-11-01

    Full Text Available The feature extraction plays a very important role in iris recognition. Recent researches on multiscale analysis provide good opportunity to extract more accurate information for iris recognition. In this work, a new directional iris texture features based on 2-D Fast Discrete Curvelet Transform (FDCT is proposed. The proposed approach divides the normalized iris image into six sub-images and the curvelet transform is applied independently on each sub-image. The anisotropic feature vector for each sub-image is derived using the directional energies of the curvelet coefficients. These six feature vectors are combined to create the resultant feature vector. During recognition, the nearest neighbor classifier based on Euclidean distance has been used for authentication. The effectiveness of the proposed approach has been tested on two different databases namely UBIRIS and MMU1. Experimental results show the superiority of the proposed approach.

  11. Waves from Propulsion Systems of Fast Ferries

    DEFF Research Database (Denmark)

    Taatø, Søren Haugsted; Aage, Christian; Arnskov, Michael M.

    1998-01-01

    Waves from fast ferries have become an environmental problem of growing concern to the public. Fast ferries produce not only higher waves than conventional ships but also fundamentally different wave systems when they sail at supercritical speeds. Hitherto, ship waves have been considered as being...... generated by the ship hulls alone. Whereas this assumption may be reasonable for conventional ships with large hulls and limited propulsive power, the situation is different for fast ferries with their smaller hulls and very large installed power. A simple theoretical model and a series of model tests...... on a monohull fast ferry seem to indicate that a substantial part of the wave-making can be directly attributed to the propulsion system itself. Thus, two wave systems are created with different phases, but with similar frequency contents, which means that they merge into one system behind the ship, very...

  12. Development of a SISAK extraction system for chemical studies of element 108, hassium

    Energy Technology Data Exchange (ETDEWEB)

    Samadani, F.; Alstad, J.; Bjoernstad, T.; Stavsetra, L.; Omtvedt, J.P. [Oslo Univ. (Germany). Dept. of Chemistry

    2010-07-01

    A liquid-liquid extraction system suitable for studies of chemical properties of Hs (element 108), in the form of HsO{sub 4}, was developed using {gamma}-emitting isotopes of its homologue Os. The system is targeted for the fast on-line extraction system SISAK, which operates in a continuous manner and is suitable for liquid-phase studies of transactinide elements. The distribution of OsO{sub 4} between various dilute NaOH solutions and toluene was studied. Both batch and SISAK on-line experiments were performed to develop an appropriate system. From analysis of the extraction curves equilibrium constants for the formation of the presumed complexes, Na[OsO{sub 4}(OH)] and Na{sub 2}[OsO{sub 4}(OH){sub 2}], were obtained: K{sub 1} = (1 {+-} 0.5) x 10{sup 4} and K{sub 2} = 12 {+-} 8, respectively. The SISAK system includes a liquid-scintillation detection system for {alpha} measurements. Due to quenching effects it is not possible to perform direct measurement of the aqueous phase {alpha}'s. Therefore, a two-stage extraction method that provides an indirect measurement of the activity in the aqueous phase was developed as part of the proposed system for Hs: Acidification of the raffinate from the first stage result in recovery of OsO{sub 4}, which is highly extractable into toluene. The yield of extraction in the second step, from 0.01 M NaOH solution after acidification with H{sub 2}SO{sub 4} solution, was (90 {+-} 3)%. (orig.)

  13. Asymmetric anode and cathode extraction structure fast recovery diode

    Science.gov (United States)

    Xie, Jiaqiang; Ma, Li; Gao, Yong

    2018-05-01

    This paper presents an asymmetric anode structure and cathode extraction fast and soft recovery diode. The device anode is partial-heavily doped and partial-lightly doped. The P+ region is introduced into the cathode. Firstly, the characteristics of the diode are simulated and analyzed. Secondly, the diode was fabricated and its characteristics were tested. The experimental results are in good agreement with the simulation results. The results show that, compared with the P–i–N diode, although the forward conduction characteristic of the diode is declined, the reverse recovery peak current is reduced by 47%, the reverse recovery time is shortened by 20% and the softness factor is doubled. In addition, the breakdown voltage is increased by 10%. Project supported by the National Natural Science Foundation of China (No. 51177133).

  14. Antifouling booster biocide extraction from marine sediments: a fast and simple method based on vortex-assisted matrix solid-phase extraction.

    Science.gov (United States)

    Caldas, Sergiane Souza; Soares, Bruno Meira; Abreu, Fiamma; Castro, Ítalo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto

    2018-03-01

    This paper reports the development of an analytical method employing vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of diuron, Irgarol 1051, TCMTB (2-thiocyanomethylthiobenzothiazole), DCOIT (4,5-dichloro-2-n-octyl-3-(2H)-isothiazolin-3-one), and dichlofluanid from sediment samples. Separation and determination were performed by liquid chromatography tandem-mass spectrometry. Important MSPD parameters, such as sample mass, mass of C18, and type and volume of extraction solvent, were investigated by response surface methodology. Quantitative recoveries were obtained with 2.0 g of sediment sample, 0.25 g of C18 as the solid support, and 10 mL of methanol as the extraction solvent. The MSPD method was suitable for the extraction and determination of antifouling biocides in sediment samples, with recoveries between 61 and 103% and a relative standard deviation lower than 19%. Limits of quantification between 0.5 and 5 ng g -1 were obtained. Vortex-assisted MPSD was shown to be fast and easy to use, with the advantages of low cost and reduced solvent consumption compared to the commonly employed techniques for the extraction of booster biocides from sediment samples. Finally, the developed method was applied to real samples. Results revealed that the developed extraction method is effective and simple, thus allowing the determination of biocides in sediment samples.

  15. Colour Fastness and Tensile Strength of Cotton Fabric Dyed with Natural Extracts of Alkanna tinctoria by Continuous Dyeing Technique

    International Nuclear Information System (INIS)

    Khattak, S. P.; Rafique, S.; Inayat, F.; Ahmad, B.

    2015-01-01

    A natural dye extracted from the roots of alkanet (Alkanna tinctoria) was applied on cotton fabric by pad-steam dyeing technique. The study was designed to evaluate the colour fastness and tensile properties of dyed cotton after using various mordants, cationizing agents, UV absorbers and crosslinkers with this natural dye. Metallic mordants included aluminium sulphate, copper sulphate, ferric chloride, potassium dichromate and hydrated potassium aluminum sulphate or alum. Alkanet root extract produced variety of green shades with different dyeing auxiliaries. Better wash, light, crocking fastness; good colour coordinates such as chroma, hue, colour strength and increase in tensile strength was accomplished with post-mordanting of CuSO/sub 4/. Cationization of cotton with quaternary ammonium compound (both pre-treatment and post-treatment) and post-finishing with soft polyurethane emulsion has enhanced the fastness properties, tensile strength as well as relative colour strength (K/S) , whereas, reactive UV absorber based on oxalanilide and heterocyclic compound as UV absorber greatly increased the light fastness of alkanet dyed cotton. Crosslinkers applied with alkanet dye on cotton (methylolation product based on glyoxalmonourein, modified dimethyloldihydroxyethylene urea, modified dihydroxy ethylene urea) also improved the fastness but could not bring further development in the shade and K/S value of the dyed sample. (author)

  16. Fast beam cut-off method in RF-knockout extraction for spot-scanning

    CERN Document Server

    Furukawa, T

    2002-01-01

    An irradiation method with magnetic scanning has been developed in order to provide accurate irradiation even for an irregular target shape. The scanning method has strongly required a lower ripple of the beam spill and a faster response to beam-on/off in slow extraction from a synchrotron ring. At HIMAC, RF-knockout extraction has utilized a bunched beam to reduce the beam-spill ripple. Therefore, particles near the resonance can be spilled out from the separatrices by synchrotron oscillation as well as by a transverse RF field. From this point of view, a fast beam cut-off method has been proposed and verified by both simulations and experiments. The maximum delay from the beam cut-off signal to beam-off has been improved to around 60 mu s from 700 mu s by a usual method. Unwanted dose has been considerably reduced by around a factor of 10 compared with that by the usual method.

  17. Developments of optical fast-gated imaging systems

    International Nuclear Information System (INIS)

    Koehler, H.A.; Kotecki, D.

    1984-08-01

    Several fast-gated imaging systems to measure ultra-fast single-transient data have been developed for time-resolved imaging of pulsed radiation sources. These systems were designed to achieve image recording times of 1 to 3 ms and dynamic ranges of >200:1 to produce large two-dimensional images (greater than or equal to 10 4 spatial points) of 1 to 2 ns exposure and small two-dimensional images (less than or equal to 200 spatial points) of less than or equal to 0.5 ns exposure. Both MCP intensified solid-state two-dimensional framing cameras and streak camera/solid-state camera systems were used; the framing camera system provides snap shots with high spatial resolution whereas the streak camera system provides for limited spatial points each with high temporal resolution. Applications of these systems include electron-beam, x-ray, gamma-ray, and neutron diagnostics. This report reviews the characteristics of the major components of fast-gated imaging systems developed at Lawrence Livermore National Laboratory. System performances are described in view of major experiments, and the diagnostic requirements of new experiments in atomic physics (x-ray lasers) and nuclear physics (fusion) are indicated

  18. Panofsky magnet for the beam extraction from the synchrotron using a fast Q-magnet and RF-knockout

    Science.gov (United States)

    Masubuchi, S.; Nakanishi, T.

    2011-12-01

    The fast control of the beam spill extracted from a synchrotron is a key function for the spot scanning irradiation in cancer therapy application. The authors propose an extraction method which uses the quadruple field of fast response, as well as the RF-knockout. A Panofsky magnet was developed as a quadruple magnet, with a frequency response of around 10 kHz. The Panofsky magnet has a rectangular beam aperture and plate coils attached to the pole face. A model magnet has been manufactured with ferrite, and static and dynamic magnetic fields were measured. From the measurement we observed that the effects of eddy current in the plate coils were large and the uniformity of the magnetic field gradient in the beam aperture was worse than ±5% with a plate thickness of 0.02 cm and a frequency of current of 10 kHz. For the future, in a detailed design the eddy current effects have to be taken into account.

  19. Reactivity changes in hybrid thermal-fast reactor systems during fast core flooding

    International Nuclear Information System (INIS)

    Pesic, M.

    1994-09-01

    A new space-dependent kinetic model in adiabatic approximation with local feedback reactivity parameters for reactivity determination in the coupled systems is proposed in this thesis. It is applied in the accident calculation of the 'HERBE' fast-thermal reactor system and compared to usual point kinetics model with core-averaged parameters. Advantages of the new model - more realistic picture of the reactor kinetics and dynamics during local large reactivity perturbation, under the same heat transfer conditions, are underlined. Calculated reactivity parameters of the new model are verified in the experiments performed at the 'HERBE' coupled core. The model has shown that the 'HERBE' safety system can shutdown reactor safely and fast even in the case of highly set power trip and even under conditions of big partial failure of the reactor safety system (author)

  20. Fast Access Data Acquisition System (FADAS)

    International Nuclear Information System (INIS)

    Katsman, Vladimir

    1998-01-01

    Our goal in this program is to develop Fast Access Data Acquisition System (FADAS) by combining the flexibility of Multilink's GaAs and InP electronics and electro-optics with an extremely high data rate for the efficient handling and transfer of collider experimental data. This novel solution is based on Multilink's and Los Alamos National Laboratory's (LANL) unique components and technologies for extremely fast data transfer, storage, and processing

  1. Generalized fast feedback system in the SLC

    International Nuclear Information System (INIS)

    Hendrickson, L.; Allison, S.; Gromme, T.; Himel, T.; Krauter, K.; Rouse, F.; Sass, R.; Shoaee, H.

    1991-11-01

    A generalized fast feedback system has been developed to stabilize beams at various locations in the SLC. The system is designed to perform measurements and change actuator settings to control beam states such as position, angle and energy on a pulse to pulse basis. The software design is based on the state space formalism of digital control theory. The system is database-driven, facilitating the addition of new loops without requiring additional software. A communications system, KISNet, provides fast communications links between microprocessors for feedback loops which involve multiple micros. Feedback loops have been installed in seventeen locations throughout the SLC and have proven to be invaluable in stabilizing the machine

  2. Pyrochemical reprocessing of molten salt fast reactor fuel: focus on the reductive extraction step

    Directory of Open Access Journals (Sweden)

    Rodrigues Davide

    2015-12-01

    Full Text Available The nuclear fuel reprocessing is a prerequisite for nuclear energy to be a clean and sustainable energy. In the case of the molten salt reactor containing a liquid fuel, pyrometallurgical way is an obvious way. The method for treatment of the liquid fuel is divided into two parts. In-situ injection of helium gas into the fuel leads to extract the gaseous fission products and a part of the noble metals. The second part of the reprocessing is performed by ‘batch’. It aims to recover the fissile material and to separate the minor actinides from fission products. The reprocessing involves several chemical steps based on redox and acido-basic properties of the various elements contained in the fuel salt. One challenge is to perform a selective extraction of actinides and lanthanides in spent liquid fuel. Extraction of actinides and lanthanides are successively performed by a reductive extraction in liquid bismuth pool containing metallic lithium as a reductive reagent. The objective of this paper is to give a description of the several steps of the reprocessing retained for the molten salt fast reactor (MSFR concept and to present the initial results obtained for the reductive extraction experiments realized in static conditions by contacting LiF-ThF4-UF4-NdF3 with a lab-made Bi-Li pool and for which extraction efficiencies of 0.7% for neodymium and 14.0% for uranium were measured. It was concluded that in static conditions, the extraction is governed by a kinetic limitation and not by the thermodynamic equilibrium.

  3. Extracting Structure from Optical Flow Using the Fast Error Search Technique

    National Research Council Canada - National Science Library

    Srinivasan, Sridar

    1998-01-01

    ...) of an optical flow field, using fast partial search. For each candidate location on a discrete sampling of the image area, we generate a linear system of equations for determining the remaining unknowns, viz...

  4. Development of an advanced code system for fast-reactor transient analysis

    International Nuclear Information System (INIS)

    Konstantin Mikityuk; Sandro Pelloni; Paul Coddington

    2005-01-01

    FAST (Fast-spectrum Advanced Systems for power production and resource management) is a recently approved PSI activity in the area of fast spectrum core and safety analysis with emphasis on generic developments and Generation IV systems. In frames of the FAST project we will study both statics and transients core physics, reactor system behaviour and safety; related international experiments. The main current goal of the project is to develop unique analytical and code capability for core and safety analysis of critical (and sub-critical) fast spectrum systems with an initial emphasis on a gas cooled fast reactors. A structure of the code system is shown on Fig. 1. The main components of the FAST code system are 1) ERANOS code for preparation of basic x-sections and their partial derivatives; 2) PARCS transient nodal-method multi-group neutron diffusion code for simulation of spatial (3D) neutron kinetics in hexagonal and square geometries; 3) TRAC/AAA code for system thermal hydraulics; 4) FRED transient model for fuel thermal-mechanical behaviour; 5) PVM system as an interface between separate parts of the code system. The paper presents a structure of the code system (Fig. 1), organization of interfaces and data exchanges between main parts of the code system, examples of verification and application of separate codes and the system as a whole. (authors)

  5. Design and installation of the MSE septum system in the new LSS4 extraction channel of the SPS

    CERN Document Server

    Balhan, B; Guinand, R; Luiz, F; Rizzo, A; Weterings, W; CERN. Geneva. AB Department

    2003-01-01

    For the extraction of the beam from the Super Proton Synchrotron (SPS) to ring 2 of the Large Hadron Collider (LHC) and the CERN Neutrino to Gran Sasso (CNGS) facility, a new fast-extraction system has been installed in the long straight section LSS4 of the SPS. Besides extraction bumpers, enlarged aperture quadrupoles and extraction kicker magnets (MKE), six conventional DC septum magnets (MSE) are used. These magnets are mounted on a single mobile retractable support girder, which is motorised in order to optimise the local SPS aperture during setting up. The MSE septa are connected by a so-called plug-in system to a rigid water-cooled bus bar, which itself is powered by water-cooled cables. In order to avoid destruction of the septum magnet coils by direct impact of the extracted beam, a dilution element (TPSG) has been placed immediately upstream of the first septum coil. The whole system is kept at the required vacuum pressure by ion pumps attached to separate modules (MP). In this note we present the de...

  6. AFCI : Co-extraction impacts on LWR and fast reactor fuel cycles

    International Nuclear Information System (INIS)

    Taiwo, T. A.; Szakalay, F. J.; Kim, T. K.; Hill, R. N.; Nuclear Engineering Division

    2007-01-01

    A systematic investigation of the impact of the co-extraction COEXTM process on reactor performance has been performed. The proliferation implication of the process was also evaluated using the critical mass, radioactivity, decay heat and neutron and gamma source rates and gamma doses as indicators. The use of LWR-spent-uranium-based MOX fuel results in a higher initial plutonium content requirement in an LWR MOX core than if natural uranium based MOX fuel is used (by about 1%); the plutonium for both cases is derived from the spent LWR spent fuel. More transuranics are consequently discharged in the spent fuel of the MOX core. The presence of U-236 in the initial fuel was also found to result in higher content of Np-237 in the spent MOX fuel and less consumption of Pu-238 and Am-241 in the MOX core. The higher quantities of Np-237 (factor of 5), Pu-238 (20%) and Am-241 (14%) decrease the effective repository utilization, relative to the use of natural uranium in the PWR MOX core. Additionally, the minor actinides continue to accumulate in the fuel cycle, even if the U-Pu co-extraction products are continuously recycled in the PWR cores, and thus a solution is required for the minor actinides. The utilization of plutonium derived from LWR spent fuel versus weapons-grade plutonium for the startup core of a 1,000 MWT advanced burner fast reactor (ABR) increases the TRU content by about 4%. Differences are negligible for the equilibrium recycle core. The impact of using reactor spent uranium instead of depleted uranium was found to be relatively smaller in the fast reactor (TRU content difference less than 0.4%). The critical masses of the co-extraction products were found to be higher than that of weapons-grade plutonium and the decay heat and radiation sources of the materials (products) were also found to be generally higher than that of weapons-grade plutonium (WG-Pu) in the transuranics content range of 0.1 to 1.0 in the heavy-metal. The magnitude of the

  7. Generalized fast feedback system in the SLC

    International Nuclear Information System (INIS)

    Hendrickson, L.; Allison, S.; Gromme, T.; Himel, T.; Krauter, K.; Rouse, F.; Sass, R.; Shoaee, H.

    1992-01-01

    A generalized fast feedback system has been developed to stabilize beams at various locations in the SLC. The system is designed to perform measurements and change actuator settings to control beam states such as position, angle and energy on a pulse to pulse basis. The software design is based on the state space formalism of digital control theory. The system is database-driven, facilitating the addition of new loops without requiring additional software. A communications system, KISNet, provides fast communications links between microprocessors for feedback loops which involve multiple micros. Feedback loops have been installed in seventeen locations throughout the SLC and have proven to be invaluable in stabilizing the machine. (author)

  8. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  9. Extraction systems of the SPS

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    A pair of prototype septum magnets for the extraction systems of the SPS. Each of the two extraction systems will contain eighteen of these septum magnets (eight with a 4 mm septum and ten with a 16 mm septum) mounted in pairs in nine vacuum tanks.

  10. Fast Swinnex Filtration (FSF): A fast and robust sampling and extraction method suitable for metabolomics analysis of cultures grown in complex media

    DEFF Research Database (Denmark)

    McCloskey, Douglas; Utrilla, Jose; Naviaux, Robert K.

    2015-01-01

    , we develop a fast-filtration method using pressuredriven Swinnex filters. We show that the method is fast enough to provide an accurate snapshot of intracellular metabolism, reduces matrix interference from the media to improve the number of compounds that can be detected, and is applicable...... to anaerobic and aerobic liquid cultures grown in a variety of culturing systems. Furthermore, we apply the fast filtration method to investigate differences in the absolute intracellular metabolite levels of anaerobic cultures grown in minimal and complex media....

  11. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids

    NARCIS (Netherlands)

    Schellen, A.; Ooms, B.; Lagemaat, D. van de; Vreeken, R.; Dongen, W.D. van

    2003-01-01

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS

  12. Diamond Light Source Booster fast orbit feedback system

    International Nuclear Information System (INIS)

    Gayadeen, S.; Duncan, S.R.; Christou, C.; Heron, M.T.; Rowland, J.

    2012-01-01

    The Fast Orbit Feedback system that has been installed on the Diamond Light Source Storage ring has been replicated on the Booster synchrotron in order to provide a test bed for the development of the Storage Ring controller design. To realise this the Booster is operated in DC mode. The electron beam is regulated in two planes using the Fast Orbit Feedback system, which takes the beam position from 22 beam position monitors for each plane, and calculates offsets to 44 corrector power supplies at a sample rate of 10 kHz. This paper describes the design and realization of the controller for the Booster Fast Orbit Feedback, presents results from the implementation and considers future development

  13. Model reduction for slow–fast stochastic systems with metastable behaviour

    International Nuclear Information System (INIS)

    Bruna, Maria; Chapman, S. Jonathan; Smith, Matthew J.

    2014-01-01

    The quasi-steady-state approximation (or stochastic averaging principle) is a useful tool in the study of multiscale stochastic systems, giving a practical method by which to reduce the number of degrees of freedom in a model. The method is extended here to slow–fast systems in which the fast variables exhibit metastable behaviour. The key parameter that determines the form of the reduced model is the ratio of the timescale for the switching of the fast variables between metastable states to the timescale for the evolution of the slow variables. The method is illustrated with two examples: one from biochemistry (a fast-species-mediated chemical switch coupled to a slower varying species), and one from ecology (a predator–prey system). Numerical simulations of each model reduction are compared with those of the full system

  14. Engineering Design of ITER Prototype Fast Plant System Controller

    Science.gov (United States)

    Goncalves, B.; Sousa, J.; Carvalho, B.; Rodrigues, A. P.; Correia, M.; Batista, A.; Vega, J.; Ruiz, M.; Lopez, J. M.; Rojo, R. Castro; Wallander, A.; Utzel, N.; Neto, A.; Alves, D.; Valcarcel, D.

    2011-08-01

    The ITER control, data access and communication (CODAC) design team identified the need for two types of plant systems. A slow control plant system is based on industrial automation technology with maximum sampling rates below 100 Hz, and a fast control plant system is based on embedded technology with higher sampling rates and more stringent real-time requirements than that required for slow controllers. The latter is applicable to diagnostics and plant systems in closed-control loops whose cycle times are below 1 ms. Fast controllers will be dedicated industrial controllers with the ability to supervise other fast and/or slow controllers, interface to actuators and sensors and, if necessary, high performance networks. Two prototypes of a fast plant system controller specialized for data acquisition and constrained by ITER technological choices are being built using two different form factors. This prototyping activity contributes to the Plant Control Design Handbook effort of standardization, specifically regarding fast controller characteristics. Envisaging a general purpose fast controller design, diagnostic use cases with specific requirements were analyzed and will be presented along with the interface with CODAC and sensors. The requirements and constraints that real-time plasma control imposes on the design were also taken into consideration. Functional specifications and technology neutral architecture, together with its implications on the engineering design, were considered. The detailed engineering design compliant with ITER standards was performed and will be discussed in detail. Emphasis will be given to the integration of the controller in the standard CODAC environment. Requirements for the EPICS IOC providing the interface to the outside world, the prototype decisions on form factor, real-time operating system, and high-performance networks will also be discussed, as well as the requirements for data streaming to CODAC for visualization and

  15. FAST: FAST Analysis of Sequences Toolbox

    Directory of Open Access Journals (Sweden)

    Travis J. Lawrence

    2015-05-01

    Full Text Available FAST (FAST Analysis of Sequences Toolbox provides simple, powerful open source command-line tools to filter, transform, annotate and analyze biological sequence data. Modeled after the GNU (GNU’s Not Unix Textutils such as grep, cut, and tr, FAST tools such as fasgrep, fascut, and fastr make it easy to rapidly prototype expressive bioinformatic workflows in a compact and generic command vocabulary. Compact combinatorial encoding of data workflows with FAST commands can simplify the documentation and reproducibility of bioinformatic protocols, supporting better transparency in biological data science. Interface self-consistency and conformity with conventions of GNU, Matlab, Perl, BioPerl, R and GenBank help make FAST easy and rewarding to learn. FAST automates numerical, taxonomic, and text-based sorting, selection and transformation of sequence records and alignment sites based on content, index ranges, descriptive tags, annotated features, and in-line calculated analytics, including composition and codon usage. Automated content- and feature-based extraction of sites and support for molecular population genetic statistics makes FAST useful for molecular evolutionary analysis. FAST is portable, easy to install and secure thanks to the relative maturity of its Perl and BioPerl foundations, with stable releases posted to CPAN. Development as well as a publicly accessible Cookbook and Wiki are available on the FAST GitHub repository at https://github.com/tlawrence3/FAST. The default data exchange format in FAST is Multi-FastA (specifically, a restriction of BioPerl FastA format. Sanger and Illumina 1.8+ FastQ formatted files are also supported. FAST makes it easier for non-programmer biologists to interactively investigate and control biological data at the speed of thought.

  16. Fast determination of trace elements in organic fertilizers using a cup-horn reactor for ultrasound-assisted extraction and fast sequential flame atomic absorption spectrometry.

    Science.gov (United States)

    Teixeira, Leonel Silva; Vieira, Heulla Pereira; Windmöller, Cláudia Carvalhinho; Nascentes, Clésia Cristina

    2014-02-01

    A fast and accurate method based on ultrasound-assisted extraction in a cup-horn sonoreactor was developed to determine the total content of Cd, Co, Cr, Cu, Mn, Ni, Pb and Zn in organic fertilizers by fast sequential flame atomic absorption spectrometry (FS FAAS). Multivariate optimization was used to establish the optimal conditions for the extraction procedure. An aliquot containing approximately 120 mg of the sample was added to a 500 µL volume of an acid mixture (HNO3/HCl/HF, 5:3:3, v/v/v). After a few minutes, 500 µL of deionized water was added and eight samples were simultaneously sonicated for 10 min at 50% amplitude, allowing a sample throughput of 32 extractions per hour. The performance of the method was evaluated with a certified reference material of sewage sludge (CRM 029). The precision, expressed as the relative standard deviation, ranged from 0.58% to 5.6%. The recoveries of analytes were found to 100%, 109%, 96%, 92%, 101%, 104% and 102% for Cd, Cr, Cu, Mn, Ni, Pb and Zn, respectively. The linearity, limit of detection and limit of quantification were calculated and the values obtained were adequate for the quality control of organic fertilizers. The method was applied to the analysis of several commercial organic fertilizers and organic wastes used as fertilizers, and the results were compared with those obtained using the microwave digestion procedure. A good agreement was found between the results obtained by microwave and ultrasound procedures with recoveries ranging from 80.4% to 117%. Two organic waste samples were not in accordance with the Brazilian legislation regarding the acceptable levels of contaminants. © 2013 Published by Elsevier B.V.

  17. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  18. A System for Fast Navigation of Autonomous Vehicles

    Science.gov (United States)

    1991-09-01

    AD-A243 523 4, jj A System for Fast Navigation of Autonomous Vehicles Sanjiv Singh, Dai Feng, Paul Keller, Gary Shaffer, Wen Fan Shi, Dong Hun Shin...FUNDING NUMBERS A System for Fast Navigation of Autonomous Vehicles 6. AUTHOR(S) S. Singh, D. Feng, P. Keller, G. Shaffer, W.F. Shi, D.H. Shin, J. West...common in the control of autonomous vehicles to establish the necessary kinematic models but to ignore an explicit representation of the vehicle dynamics

  19. The method for simultaneous extraction and back extraction in liquid three-phase system and equipment for simultaneous extraction and back extraction in liquid three-phase system

    International Nuclear Information System (INIS)

    Palyska, W.; Chmielewski, A.G.

    1992-01-01

    The method for simultaneous extraction and back extraction in liquid three-phase system has been worked out. The equipment designed for that process has been also subject of the patent. The interesting component is extracted first to intermediate phase consists of magnetic solvent keeping two extracting phases separately. The intermediate magnetic liquid has been kept in its position using a stable magnet maintained on the surface of the extraction vessel. Then the component pass from intermediate phase to the third phase as a result of back extraction. Mixing in the extraction and back extraction zones is organized by means of rotating shaft going along the whole apparatus. The extraction and back extraction processes occur simultaneously as a result of continuous flow of solvent in their zones. The single extraction back extraction facilities can be joined in larger batteries. 3 figs

  20. Slow extraction control system of HIRFL-CSR

    International Nuclear Information System (INIS)

    Liu Wufeng; Qiao Weimin; Yuan Youjin; Mao Ruishi; Zhao Tiecheng

    2013-01-01

    For heavy-ion radiotherapy, HIRFL-CSR (Heavy Ion Research Facility in Lanzhou-Cooler Storage Ring) needs a long term uniform ion beam extraction from HIRFL-CSR main ring to high energy beam transport line to meet the requirement of heavy-ion radiotherapy's ion beam. Slow extraction control system uses the synchronous signal of HIRFL-CSR control system's timing system to realize process control. When the synchronous event data of HIRFL-CSR control system's timing system trigger controlling and changing data (frequency value, tune value, voltage value), the waveform generator will generate waveform by frequency value, tune value and voltage value, and will amplify the generated waveform by power amplifier to electrostatic deflector to achieve RF-KO slow extraction. The synchronous event receiver of slow extraction system is designed by using FPGA and optical fiber interface to keep high transmission speed and anti-jamming. HIRFL-CSR's running for heavy-ion radiotherapy and ten thousand seconds long period slow extraction experiments show that slow extraction control system is workable and can meet the requirement of heavy-ion radiotherapy's ion beam. (authors)

  1. Rate phenomena in uranium extraction by amines

    International Nuclear Information System (INIS)

    Coleman, C.F.; McDowell, W.J.

    1979-01-01

    Kinetics studies and other rate measurements are reviewed in the amine extraction of uranium and of some other related and associated metal ions. Equilibration is relatively fast in the uranium sulfate systems most important to uranium hydrometallurgy. Significantly slow equilibration has been encountered in some other systems. Most of the recorded rate information, both qualitative and quantitative, has come from exploratory and process-development work, while some kinetics studies have been directed specifically toward elucidation of extraction mechanisms. 71 references

  2. The custodian administered research extract server: "improving the pipeline" in linked data delivery systems.

    Science.gov (United States)

    Eitelhuber, Tom; Davis, Geoff

    2014-01-01

    At Western Australia's Data Linkage Branch (DLB) the extraction of linked data has become increasingly complex over the past decade and classical methods of data delivery are unsuited to the larger extractions which have become the norm. The Custodian Administered Research Extract Server (CARES) is a fast, accurate and predictable approach to linked data extraction. The Data Linkage Branch (DLB) creates linkage keys within and between datasets. To comply with the separation principal, these keys are sent to applicable data collection agencies for extraction. Routing requests through multiple channels is inefficient and makes it hard to monitor work and predict delivery times. CARES was developed to address these shortcomings and involved ongoing consultation with the Custodians and staff of collections, plus challenges of hardware, programming, governance and security. The introduction of CARES has reduced the workload burden of linked data extractions, while improving the efficiency, stability and predictability of turnaround times. As the scope of a linkage system broadens, challenges in data delivery are inevitable. CARES overcomes multiple obstacles with no sacrifice to the integrity, confidentiality or security of data. CARES is a valuable component of linkage infrastructure that is operable at any scale and adaptable to many data environments.

  3. SNS EXTRACTION KICKER POWER SUPPLY PROTOTYPE TEST

    International Nuclear Information System (INIS)

    MI, J.L.; SANDBERG, J.; SANDERS, R.; SOUKAS, A.; ZHANG, W.

    2000-01-01

    The SNS (Spallation Neutron Source) accumulator ring Extraction System consists of a Fast kicker and a Lambertson Septum magnet. The proposed design will use 14 kicker magnets powered by an Extraction Kicker Power Supply System. They will eject the high power beam from the SNS accumulator ring into RTBT (Ring to Target Beam Tunnel) through a Lambertson Septum magnet. This paper describes some test results of the SNS Extraction Kicker power supply prototype. The high repetition rate of 60 pulse per second operation is the challenging part of the design. In the prototype testing, a 3 kA damp current of 700ns pulse-width, 200 nS rise time and 60 Hz repetition rate at 32 kV PFN operation voltage has been demonstrated. An Extraction kicker power supply system design diagram is depicted

  4. A Fast Algorithm of Cartographic Sounding Selection

    Institute of Scientific and Technical Information of China (English)

    SUI Haigang; HUA Li; ZHAO Haitao; ZHANG Yongli

    2005-01-01

    An effective strategy and framework that adequately integrate the automated and manual processes for fast cartographic sounding selection is presented. The important submarine topographic features are extracted for important soundings selection, and an improved "influence circle" algorithm is introduced for sounding selection. For automatic configuration of soundings distribution pattern, a special algorithm considering multi-factors is employed. A semi-automatic method for solving the ambiguous conflicts is described. On the basis of the algorithms and strategies a system named HGIS for fast cartographic sounding selection is developed and applied in Chinese Marine Safety Administration Bureau (CMSAB). The application experiments show that the system is effective and reliable. At last some conclusions and the future work are given.

  5. Fast Initialization of Bubble-Memory Systems

    Science.gov (United States)

    Looney, K. T.; Nichols, C. D.; Hayes, P. J.

    1986-01-01

    Improved scheme several orders of magnitude faster than normal initialization scheme. State-of-the-art commercial bubble-memory device used. Hardware interface designed connects controlling microprocessor to bubblememory circuitry. System software written to exercise various functions of bubble-memory system in comparison made between normal and fast techniques. Future implementations of approach utilize E2PROM (electrically-erasable programable read-only memory) to provide greater system flexibility. Fastinitialization technique applicable to all bubble-memory devices.

  6. Design of a molten heavy-metal coolant and target for fast-thermal accelerator driven sub-critical system (ADS)

    International Nuclear Information System (INIS)

    Satyamurthy, P.; Degwekar, S.B.; Nema, P.K.

    2001-01-01

    Accelerator Driven sub-critical Systems (ADS) have evoked considerable interest in recent years. The Energy Amplifier concept developed by C. Rubbia and others at CERN incorporates a buoyancy driven, lead-coolant primary system for extracting the heat generated in the fast reactor as well as that in neutron spallation target. In earlier publications, our BARC group has proposed a one-way coupled booster reactor system which could be operated at proton beam currents as low as 1-2 mA for a power output of 750 MW th . Here, the basic idea is to have a fast booster reactor zone of low power (- 100 MW th ) which is separated by a large gap from the main thermal reactor zone. In this arrangement, the spallation neutron source feeds neutrons to the fast reactor zone where neutrons are further multiplied. Further in this system, the neutrons from the booster region enter the main reactor but very few neutrons from main reactor return to booster, thus ensuring one-way coupling. In earlier work, several possible configurations of the booster and thermal regions were presented. In the present work, we describe an engineering design particularly with respect to thermal hydraulics of lead/lead-bismuth eutectic coolant also acting as spallation neutron source. This hybrid ADS reactor consists of fast and thermal reactor zones producing about 100 MW th and 650 MW th respectively. The scheme of the system is shown. The fast core consists of 48 hexagonal fuel bundles each containing 169 fuel pins of 8.2 mm diameter arranged in 11.4 mm triangular array pitch. The average thermal power per fuel pin is about 13.46 kw. However, due to neutron flux peaking effect, the maximum fuel pin power can be up to 2.5 times this average power. The thermal reactor consists of heavy water as moderator and coolant similar to a typical CANDU type Indian PHWR except for fuel composition. Though the gap between fast and thermal zones essentially provides one way coupling of neutron flux, a thermal

  7. Design project of fast subcritical system 'Mala Lasta'

    International Nuclear Information System (INIS)

    Milosevic, M.; Stefanovic, D.; Popovic, D.; Pesic, M.; Zavaljevski, N.; Nikolic, D.; Arsenovic, M.

    1988-10-01

    This report contains two parts. Part one covers the objective and fundamental elements for the choice of fast subcritical system 'Mala Lasta', review of the existing fast subcritical assemblies, and a description of the available domestic computer codes applied for calculating neutron reactor parameters. Comparison of results obtained by these codes for a number of existing subcritical assemblies was used for the choice of the design project described in part two of this report. It contains detailed description of the operating parameters of the chosen subcritical system based on the obtained calculated parameters

  8. Acacia nilotica leave extract and glyburide: comparison of fasting flood glucose, serum insulin, b-thromboglubulin levels and platelet aggregation in treptozotocin induced diabetic rats

    International Nuclear Information System (INIS)

    Asad, M.; Munir, T.A.; Afzal, N.

    2011-01-01

    Objectives: To evaluate the hypoglycaemic and anti-platelet aggregation effect of aqueous methanol extract of Acacia Nilotica (AN) leaves compared with glyburide on streptozotocin induced diabetic rats. Methods: Diabetes mellitus was induced in 90 out of 120 albino rats by administering 50 mg/kg body weight (b.w) streptozotocin and was confirmed by measuring fasting blood glucose level >200 mg/dL on fourth post-induction day. The rats were equally divided into 4 groups, A (normal control), B (diabetic control), C (diabetic rats treated with AN extract) and group D (diabetic rats treated with glyburide). The rats of group C and D were given 300 mg/kg b.w AN extract and 900 mu gm/kg b.w glyburide respectively for 3 weeks. Blood glucose was measured by gluco meter, platelet aggregation by Dia-Med method and insulin and b-thrombo globulin by ELISA technique. Results: A significant increase (p<0.05) in fasting blood glucose, b-thrombo globulin and platelet aggregation and a significant decrease (p<0.05) in insulin levels was observed in streptozotocin induced diabetic rats than the normal controls. The rats treated with AN extract and glyburide showed a significant decrease (p<0.05) in fasting blood glucose and increase (p<0.05) in insulin levels than the diabetic control rats. However, the levels in both the treatment groups remained significantly different than the normal controls. A significant decrease (p<0.05) in b-thrombo globulin levels was seen in diabetic rats treated with glyburide than the diabetic control rats and diabetic rats treated with AN extract. Conclusions: AN leaves extract result into hypoglycaemic and anti-platelet aggregation activity in diabetic rats as that of glyburide. (author)

  9. DiMeX: A Text Mining System for Mutation-Disease Association Extraction.

    Science.gov (United States)

    Mahmood, A S M Ashique; Wu, Tsung-Jung; Mazumder, Raja; Vijay-Shanker, K

    2016-01-01

    The number of published articles describing associations between mutations and diseases is increasing at a fast pace. There is a pressing need to gather such mutation-disease associations into public knowledge bases, but manual curation slows down the growth of such databases. We have addressed this problem by developing a text-mining system (DiMeX) to extract mutation to disease associations from publication abstracts. DiMeX consists of a series of natural language processing modules that preprocess input text and apply syntactic and semantic patterns to extract mutation-disease associations. DiMeX achieves high precision and recall with F-scores of 0.88, 0.91 and 0.89 when evaluated on three different datasets for mutation-disease associations. DiMeX includes a separate component that extracts mutation mentions in text and associates them with genes. This component has been also evaluated on different datasets and shown to achieve state-of-the-art performance. The results indicate that our system outperforms the existing mutation-disease association tools, addressing the low precision problems suffered by most approaches. DiMeX was applied on a large set of abstracts from Medline to extract mutation-disease associations, as well as other relevant information including patient/cohort size and population data. The results are stored in a database that can be queried and downloaded at http://biotm.cis.udel.edu/dimex/. We conclude that this high-throughput text-mining approach has the potential to significantly assist researchers and curators to enrich mutation databases.

  10. SPS extraction systems

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    One of the 3-m long electrostatics septa. The septum itself consists of 0.15 mm thick molybdenum wires with a 1.5 mm pitch. Each of the two SPS extraction systems will contain four of these electrostatic septa.

  11. Vibration extraction based on fast NCC algorithm and high-speed camera.

    Science.gov (United States)

    Lei, Xiujun; Jin, Yi; Guo, Jie; Zhu, Chang'an

    2015-09-20

    In this study, a high-speed camera system is developed to complete the vibration measurement in real time and to overcome the mass introduced by conventional contact measurements. The proposed system consists of a notebook computer and a high-speed camera which can capture the images as many as 1000 frames per second. In order to process the captured images in the computer, the normalized cross-correlation (NCC) template tracking algorithm with subpixel accuracy is introduced. Additionally, a modified local search algorithm based on the NCC is proposed to reduce the computation time and to increase efficiency significantly. The modified algorithm can rapidly accomplish one displacement extraction 10 times faster than the traditional template matching without installing any target panel onto the structures. Two experiments were carried out under laboratory and outdoor conditions to validate the accuracy and efficiency of the system performance in practice. The results demonstrated the high accuracy and efficiency of the camera system in extracting vibrating signals.

  12. System of Modelling and Calculation Analysis of Neutron- Physical Experiments at Fast Reactors

    International Nuclear Information System (INIS)

    Moiseyev, A.V.

    2008-01-01

    There is an actual task on storage, processing and analysis of the unique experimental data received on power fast reactors for their subsequent use in projects of fast reactors of new (4.) generation. For modeling and carrying out analysis of experiments the integrated computing system MODEXSYS has been developed. In this system the mechanism for consecutive calculation of a fast reactor states with the detailed description of its components is created. The system includes the database describing fast reactor states, results of neutron-physical characteristics measurements at fast reactor, calculation and benchmark models of experiments and calculation results. In system convenient search means and the special graphics shell are provided. It has Interfaces for processing of calculation results and their analysis. MODEXSYS system has been applied for analysis of three types of experiments at fast reactor: k eff , control rod worth and energy release distribution. The most important results of this analysis are described. Application of MODEXSYS system will raise accuracy and reliability of forecasting of fast reactors neutron-physical characteristics; for BN-600 reactor recommended level of accuracy is resulted. (authors)

  13. System of Modelling and Calculation Analysis of Neutron- Physical Experiments at Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Moiseyev, A.V. [SSC RF - IPPE, 1 Bondarenko Square, Obninsk, Kaluga Region 249033 (Russian Federation)

    2008-07-01

    There is an actual task on storage, processing and analysis of the unique experimental data received on power fast reactors for their subsequent use in projects of fast reactors of new (4.) generation. For modeling and carrying out analysis of experiments the integrated computing system MODEXSYS has been developed. In this system the mechanism for consecutive calculation of a fast reactor states with the detailed description of its components is created. The system includes the database describing fast reactor states, results of neutron-physical characteristics measurements at fast reactor, calculation and benchmark models of experiments and calculation results. In system convenient search means and the special graphics shell are provided. It has Interfaces for processing of calculation results and their analysis. MODEXSYS system has been applied for analysis of three types of experiments at fast reactor: k{sub eff}, control rod worth and energy release distribution. The most important results of this analysis are described. Application of MODEXSYS system will raise accuracy and reliability of forecasting of fast reactors neutron-physical characteristics; for BN-600 reactor recommended level of accuracy is resulted. (authors)

  14. Fast Burst Synchronization for Power Line Communication Systems

    Directory of Open Access Journals (Sweden)

    Lampe Lutz

    2007-01-01

    Full Text Available Fast burst synchronization is an important requirement in asynchronous communication networks, where devices transmit short data packets in an unscheduled fashion. Such a synchronization is typically achieved by means of a preamble sent in front of the data packet. In this paper, we study fast burst synchronization for power line communication (PLC systems operating below 500 kHz and transmitting data rates of up to about 500 kbps as it is typical in various PLC network applications. In particular, we are concerned with the receiver processing of the preamble signal and the actual design of preambles suitable for fast burst synchronization in such PLC systems. Our approach is comprehensive in that it takes into account the most distinctive characteristics of the power line channel, which are multipath propagation, highly varying path loss, and disturbance by impulse noise, as well as important practical constraints, especially the need for spectral shaping of the preamble signal and fast adjustment of the automatic gain control (AGC. In fact, we regard the explicit incorporation of these various requirements into the preamble design as the main contribution of this work. We devise an optimization criterion and a stochastic algorithm to search for suitable preamble sequences. A comprehensive performance comparison of a designed and two conventional preambles shows that the designed sequence is superior in terms of (a fast burst synchronization in various transmission environments, (b fast AGC adjustment, and (c compliance of its spectrum with the spectral mask applied to the data transmit signal.

  15. Fast modified signal-digit (MSD) multiplication technology and system

    Science.gov (United States)

    Sun, DeGui; He, Li-Ming; Wang, Na-Xin; Weng, Zhao-Heng

    1994-06-01

    In this paper, the carry-free property of modified-signed-digit (MSD) addition is analyzed with a space position logic encoding scheme. On this basis, MSD multiplication is discussed and a fast MSD multiplication system composed of optoelectronic logic technology and a multilayer optical interconnection architecture is propsed and studied. Finally, the effectivity of the fast MSD multiplication system is demostrated by using a 2X2 bit multiplication example and experimental results are given.

  16. Television imaging system for fast neutron radiography using baby cyclotron

    International Nuclear Information System (INIS)

    Yoshii, Koji; Miya, Kenzo; Katoh, Norihiko.

    1993-01-01

    A television imaging system for fast neutron radiography (FNR-TV) developed using the fast neutron source reactor YAYOI was applied to the baby-cyclotron based fast neutron source to get images of thick objects quickly. In the system the same technique as a current television imaging system of thermal neutron radiography was applied, while the luminescent converter was used to detect fast neutrons. Using the CR39 track etch method it took about 7 h to get an image, while the FNR-TV only 20 s enough for taking the same object. However the FNR-TV imaging result of the simulation model of a large explosive device for the space launch vehicle of H-2 type was not so good as the image taken with the CR39 track etch method. The reason was that the luminescence intensity of the FNR-TV converter was a quarter of that in the YAYOI. (author)

  17. The JET diagnostic fast central acquisition and trigger system (abstract)

    Science.gov (United States)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  18. Containment atmosphere cooling system for experimental fast reactor 'JOYO'

    International Nuclear Information System (INIS)

    Sasaki, Mikio; Hoshi, Akio; Sato, Morihiko; Takeuchi, Kaoru

    1979-01-01

    The experimental fast reactor ''JOYO'', the first sodium-cooled fast reactor in Japan, achieved the initially licensed full power operation (50 MW) in July 1978 and is now under steady operation. Toshiba has participated in the construction of this reactor as a leading manufacturer and supplied various systems. This article outlines the design philosophy, system concepts and the operating experience of the containment atmosphere cooling system which has many design interfaces throughout the whole plant and requires especially high reliability. The successful performance of this system during the reactor full-power operation owes to the spot cooling design philosophy and to the preoperational adjustment of heat load during the preheating period of reactor cooling system peculiar to FBR. (author)

  19. Fast and Low-Cost Mechatronic Recognition System for Persian Banknotes

    Directory of Open Access Journals (Sweden)

    Majid Behjat

    2014-03-01

    Full Text Available In this paper, we designed a fast and low-cost mechatronic system for recognition of eight current Persian banknotes in circulation. Firstly, we proposed a mechanical solution for avoiding extra processing time caused by detecting the place of banknote and paper angle correction in an input image. We also defined new parameters for feature extraction, including colour features (RGBR values, size features (LWR and texture features (CRLVR value. Then, we used a Multi-Layer Perceptron (MLP neural network in the recognition phase to reduce the necessary processing time. In this research, we collected a perfect database of Persian banknote images (about 4000 double-sided prevalent images. We reached about 99.06% accuracy (average for each side in final banknote recognition by testing 800 different worn, torn and new banknotes which were not part of the initial learning phase. This accuracy could increase to 99.62% in double-sided decision mode. Finally, we designed an ATmega32 microcontroller-based hardware with 16MHz clock frequency for implementation of our proposed system which can recognize sample banknotes at about 480ms and 560ms for single-sided detection and double-sided detection respectively, after image scanning.

  20. Sophistication of burnup analysis system for fast reactor

    International Nuclear Information System (INIS)

    Yokoyama, Kenji; Hirai, Yasushi; Hyoudou, Hideaki; Tatsumi, Masahiro

    2010-02-01

    Improvement on prediction accuracy for neutronics property of fast reactor cores is one of the most important study domains in terms of both achievement of high economical plant efficiency based on reasonably advanced designs and increased reliability and safety margins. In former study, considerable improvement on prediction accuracy in neutronics design has been achieved in the development of the unified constants library as a fruit of a series of critical experiments such as JUPITER in application of the reactor constant adjustments. For design of fast reactor cores, however, improvement of not only static properties but also burnup properties is very important. For such purpose, it is necessary to improve the prediction accuracy on burnup properties using actual burnup data of 'JOYO' and 'MONJU', experimental and prototype fast reactors. Recently, study on effective burnup method for minor actinides becomes important theme. However, there is a problem that analysis work tends to become inefficient for lack of functionality suitable for analysis of composition change due to burnup since the conventional analysis system is targeted to critical assembly systems. Therefore development of burnup analysis system for fast reactors with modularity and flexibility is being done that would contribute to actual core design work and improvement of prediction accuracy. In the previous research, we have developed a prototype system which has functions of performing core and burnup calculations using given constant files (PDS files) and information based on simple and easy user input data. It has also functions of fuel shuffling which is indispensable for production systems. In the present study, we implemented functions for cell calculations and burnup calculations. With this, whole steps in analysis can be carried out with only this system. In addition, we modified the specification of user input to improve the convenience of this system. Since implementations being done so

  1. The fast Amsterdam multiprocessor (FAMP) operation system

    International Nuclear Information System (INIS)

    Gosman, D.; Hertzberger, L.O.; Holthuizen, D.J.; Por, G.J.A.; Schoorel, M.

    1981-01-01

    The Fast Amsterdam Multi Processor system (FAMP system) is developed for on-line filtering and second stage triggering. The system is based on the MC 68000 microprocessor from MOTOROLA. In this report we will describe: The FAMP operating system software, the features of the slaves and supervisor in the FAMP operating system, the communication between supervisor and slaves using the dual port memories, the communication between user programs and the operating system. The hardware as well as the application of the system will be described elsewhere. (orig.)

  2. Accelerating Memory-Access-Limited HPC Applications via Novel Fast Data Compression, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A fast-paced continual increase on the ratio of CPU to memory speed feeds an exponentially growing limitation for extracting performance from HPC systems. Breaking...

  3. Accelerating Memory-Access-Limited HPC Applications via Novel Fast Data Compression, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A fast-paced continual increase on the ratio of CPU to memory speed feeds an exponentially growing limitation for extracting performance from HPC systems. Ongoing...

  4. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids.

    Science.gov (United States)

    Schellen, Anniek; Ooms, Bert; van de Lagemaat, Dick; Vreeken, Rob; van Dongen, William D

    2003-05-25

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS system were optimized in an integrated approach to maximize the application range and minimize the method development time. The optimized generic SPE-LC-MS/MS protocol was evaluated for 11 drugs with different physicochemical properties. Good quantification for 10 out of 11 of the pharmaceuticals in serum or plasma could be readily achieved. The quantitative assays gave recoveries better than 95%, lower quantification limits of 0.2-2.0 ng/ml, acceptable precision and accuracy and good linearity over 2-4 orders of magnitude. Carry-over was determined to be in the range of 0.02-0.10%, without optimization.

  5. Temporally rendered automatic cloud extraction (TRACE) system

    Science.gov (United States)

    Bodrero, Dennis M.; Yale, James G.; Davis, Roger E.; Rollins, John M.

    1999-10-01

    Smoke/obscurant testing requires that 2D cloud extent be extracted from visible and thermal imagery. These data are used alone or in combination with 2D data from other aspects to make 3D calculations of cloud properties, including dimensions, volume, centroid, travel, and uniformity. Determining cloud extent from imagery has historically been a time-consuming manual process. To reduce time and cost associated with smoke/obscurant data processing, automated methods to extract cloud extent from imagery were investigated. The TRACE system described in this paper was developed and implemented at U.S. Army Dugway Proving Ground, UT by the Science and Technology Corporation--Acuity Imaging Incorporated team with Small Business Innovation Research funding. TRACE uses dynamic background subtraction and 3D fast Fourier transform as primary methods to discriminate the smoke/obscurant cloud from the background. TRACE has been designed to run on a PC-based platform using Windows. The PC-Windows environment was chosen for portability, to give TRACE the maximum flexibility in terms of its interaction with peripheral hardware devices such as video capture boards, removable media drives, network cards, and digital video interfaces. Video for Windows provides all of the necessary tools for the development of the video capture utility in TRACE and allows for interchangeability of video capture boards without any software changes. TRACE is designed to take advantage of future upgrades in all aspects of its component hardware. A comparison of cloud extent determined by TRACE with manual method is included in this paper.

  6. Fast reciprocating probe system on the EAST superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Chang, J. F.; Wan, B. N.; Xu, G. S.; Li, B.; Xu, C. S.; Yan, N.; Wang, L.; Liu, S. C.; Jiang, M.; Liu, P. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Xiao, C. J. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Department of Physics and Engineering Physics, Plasma Physics Laboratory, University of Saskatchewan, Saskatoon SK S7N 5E2 (Canada)

    2010-11-15

    A new fast reciprocating probe system (FRPS) has been built and installed on the outer midplane of the EAST tokamak to investigate the profiles of the boundary plasma parameters such as electron density and temperature. The system consists of a two-stage motion drive mechanism: slow motion and fast motion. The fast motion is powered by a servo motor, which drives the probe horizontally up to 50 cm to scan the edge region of the EAST tokamak. The maximum velocity achieved is 2 m/s. High velocity and flexible control of the fast motion are the remarkable features of this FRPS. A specially designed connector installed at the front end of the probe shaft makes it easy to install or replace the probe head on FRPS. During the latest experimental campaign in the spring of 2010, a probe head with seven tips, including two tips for a Mach probe, has been used. An example is given for simultaneous profile measurements of the plasma temperature, plasma density, and the plasma flow velocity.

  7. A versatile fast coincidence system with memory

    International Nuclear Information System (INIS)

    Pouthas, J.

    1976-01-01

    A versatile fast coincidence system has been studied for experiments using several detectors. In this system, all the coincidence events are produced with an associated code, and thus, different kinds of events can be processed with the same experimental set-up. Also, the classification of the logical pulses gives the possibility of using a large number of ways (30 in this system). The setting of the system is very simple: there are only two time windows to adjust. (Auth.)

  8. Role of therapeutic fasting in women's health: An overview

    Directory of Open Access Journals (Sweden)

    Pradeep M.K Nair

    2016-01-01

    Full Text Available Fasting is a therapeutic tool practiced since millennia by different cultures and medical systems heterogeneously. PubMed and Google Scholar search engines were searched using the keywords “fasting,” “intermittent fasting,” “calorie restriction,” “women's health,” “women's disorders,” “fasting and aging,” and “fasting and health.” All the animal and human studies which address women's health and disorders were included in the review. Fasting has shown to improve the reproductive and mental health. It also prevents as well as ameliorates cancers and musculoskeletal disorders which are common in middle-aged and elderly women. The present studies available have limitations such as majority of the studies are preclinical studies and human studies are with lesser sample size. Future studies should address this gap by designing medically supervised fasting techniques to extract better evidence. Nevertheless, fasting can be prescribed as a safe medical intervention as well as a lifestyle regimen which can improve women's health in many folds.

  9. Advanced integrated solvent extraction systems

    Energy Technology Data Exchange (ETDEWEB)

    Horwitz, E.P.; Dietz, M.L.; Leonard, R.A. [Argonne National Lab., IL (United States)

    1997-10-01

    Advanced integrated solvent extraction systems are a series of novel solvent extraction (SX) processes that will remove and recover all of the major radioisotopes from acidic-dissolved sludge or other acidic high-level wastes. The major focus of this effort during the last 2 years has been the development of a combined cesium-strontium extraction/recovery process, the Combined CSEX-SREX Process. The Combined CSEX-SREX Process relies on a mixture of a strontium-selective macrocyclic polyether and a novel cesium-selective extractant based on dibenzo 18-crown-6. The process offers several potential advantages over possible alternatives in a chemical processing scheme for high-level waste treatment. First, if the process is applied as the first step in chemical pretreatment, the radiation level for all subsequent processing steps (e.g., transuranic extraction/recovery, or TRUEX) will be significantly reduced. Thus, less costly shielding would be required. The second advantage of the Combined CSEX-SREX Process is that the recovered Cs-Sr fraction is non-transuranic, and therefore will decay to low-level waste after only a few hundred years. Finally, combining individual processes into a single process will reduce the amount of equipment required to pretreat the waste and therefore reduce the size and cost of the waste processing facility. In an ongoing collaboration with Lockheed Martin Idaho Technology Company (LMITCO), the authors have successfully tested various segments of the Advanced Integrated Solvent Extraction Systems. Eichrom Industries, Inc. (Darien, IL) synthesizes and markets the Sr extractant and can supply the Cs extractant on a limited basis. Plans are under way to perform a test of the Combined CSEX-SREX Process with real waste at LMITCO in the near future.

  10. Fast And Flexible Modelling Of Real-Time Systems With Rtcp-Nets

    Directory of Open Access Journals (Sweden)

    Marcin Szpyrka

    2004-01-01

    Full Text Available A large number of formalisms has been proposed for real-time systems modelling. However, formal methods are not widely used in industrial software development. Such a situation could be treated as a result of a lack of suitable tools for fast designing of a model, its analysis and modification. RTCP-nets have been defined to facilitate fast modelling of embedded systems incorporating rule-based systems. Computer tools that are being developed for RTCP-nets, use a template mechanism to allow users to design models and manipulate its properties fast and effectively. Both theoretical and practical aspects of RTCP-nets are presented in the paper.

  11. Fast and Flexible Modelling of Real-Time Systems with RTCP-Nets

    Directory of Open Access Journals (Sweden)

    Marcin Szpyrka

    2004-01-01

    Full Text Available A large number of formalisms has been proposed for real-time systems modelling. However, formal methods are not widely used in industrial software development. Such a situation could be treated as a result of a lack of suitable tools for fast designing of a model, its analysis and modification. RTCP-nets have been defined to facilitate fast modelling of embedded systems incorporating rule-based systems. Computer tools that are being developed for RTCP-nets, use a template mechanism to allow users to design models and manipulate its properties fast and effectively. Both theoretical and practical aspects of RTCP-nets are presented in the paper.

  12. Modeling delayed neutron monitoring systems for fast breeder reactors

    International Nuclear Information System (INIS)

    Bunch, W.L.; Tang, E.L.

    1983-10-01

    The purpose of the present work was to develop a general expression relating the count rate of a delayed neutron monitoring system to the introduction rate of fission fragments into the sodium coolant of a fast breeder reactor. Most fast breeder reactors include a system for detecting the presence of breached fuel that permits contact between the sodium coolant and the mixed oxide fuel. These systems monitor for the presence of fission fragments in the sodium that emit delayed neutrons. For operational reasons, the goal is to relate the count rate of the delayed neutron monitor to the condition of the breach in order that appropriate action might be taken

  13. Fast and precise method of contingency ranking in modern power system

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thøgersen, Paul

    2011-01-01

    Contingency Analysis is one of the most important aspect of Power System Security Analysis. This paper presents a fast and precise method of contingency ranking for effective power system security analysis. The method proposed in this research work takes due consideration of both apparent power o...... is based on realistic approach taking practical situations into account. Besides taking real situations into consideration the proposed method is fast enough to be considered for on-line security analysis.......Contingency Analysis is one of the most important aspect of Power System Security Analysis. This paper presents a fast and precise method of contingency ranking for effective power system security analysis. The method proposed in this research work takes due consideration of both apparent power...

  14. Benchmark test of evaluated nuclear data files for fast reactor neutronics application

    International Nuclear Information System (INIS)

    Chiba, Go; Hazama, Taira; Iwai, Takehiko; Numata, Kazuyuki

    2007-07-01

    A benchmark test of the latest evaluated nuclear data files, JENDL-3.3, JEFF-3.1 and ENDF/B-VII.0, has been carried out for fast reactor neutronics application. For this benchmark test, experimental data obtained at fast critical assemblies and fast power reactors are utilized. In addition to comparing of numerical solutions with the experimental data, we have extracted several cross sections, in which differences between three nuclear data files affect significantly numerical solutions, by virtue of sensitivity analyses. This benchmark test concludes that ENDF/B-VII.0 predicts well the neutronics characteristics of fast neutron systems rather than the other nuclear data files. (author)

  15. SISAK liquid-liquid extraction experiments with preseparated 257Rf

    International Nuclear Information System (INIS)

    Omtvedt, Jon Petter; Alstad, J.; Breivik, H.; Dyve, J.E.; Eberhardt, K.; Folden III, C.M.; Ginter, T.; Gregorich, K.E.; Hult, E.A.; Johansson, M.; Kirbach, U.W.; Lee, D.M.; Mendel, M.; Nahler, A.; Ninov, V.; Omtvedt, L.A.; Patin, J.B.; Skarnemark, G.; Stavsetra, L.; Sudowe, R.; Wiehl, N.; Wierczinski, B.; Wilk, P.A.; Zielinski, P.M.; Kratz, J.V.; Trautmann, N.; Nitsche, H.; Hoffman, D.C.

    2002-01-01

    The SISAK liquid-liquid extraction system was used to extract 4.0-s 257Rf. The 257Rf was produced in the reaction 208Pb(50Ti, 1n)257Rf with 237-MeV beam energy on target, separated in the Berkeley Gas-filled Separator (BGS) and transferred to a gas jet using the Recoil Transfer Chamber (RTC). The activity delivered by the gas jet was dissolved in 6-M HNO3 and Rf was extracted into 0.25-M dibutyl-phosphoric acid in toluene. This was the first time a transactinide, i.e., an element with Z >= 104, was extracted and unequivocally identified by the SISAK system. Thus, this pilot experiment demonstrates that the fast liquid-liquid extraction system SISAK, in combination with liquidscintillation detectors, can be used for investigating the chemical properties of the transactinides. The extraction result is in accordance with the behaviour shown by the Rf group IV homologues Zr and Hf

  16. Experimental study of suitable methods for measuring the radioactivity of 90Sr during its fast quantitation by extraction with dicarbollides

    International Nuclear Information System (INIS)

    Svoboda, K.; Kyrs, M.

    1994-04-01

    The measurement of activity of 90 Sr during its fast isolation by extraction with cobalt dicarbollide and Slovafol 909 in a nitrobenzene-carbon tetrachloride mixed solvent and re-extraction with 0.15 M Chelaton IV at pH 10.2 was investigated. The use of a liquid scintillator allows the effect of the 90 Y beta activity to be eliminated more efficiently than if the evaporation residue is measured with a solid scintillator. Traces of dicarbollide, nitrobenzene and CCl 4 passed into the aqueous solution exert an unfavorable effect by shifting the spectral curve of the 90 Sr+ 90 Y beta radiation towards lower energies, the shift being dependent on the concentration of the above interferents in the aqueous phase. This effect can be eliminated by extracting the aqueous phase with the same volume of octyl alcohol or amyl acetate; while removing the organic interferents, this extraction brings about no apparent loss of strontium. (author). 3 tabs., 7 figs., 5 refs

  17. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    Science.gov (United States)

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Fast Dump of the ATLAS Toroids

    CERN Document Server

    Dudarev, A; Volpini, Giovanni; Dudarev, Alexey; Kate, Herman Ten

    2010-01-01

    The toroidal magnet system of the ATLAS Detector at CERN consists of a Barrel Toroid (BT) and two End Cap Toroids (ECT-A and ECT-C). Each toroid is built up from eight racetrack coils wound with an aluminum stabilized NbTi conductor and indirectly cooled by forced flow liquid helium. The three toroids operate in series at 20.5 kA with a total stored energy of 1.5 GJ. In order to verify the reliability and effectiveness of the quench protection system, series of fast dump tests have been performed first of the single toroids and finally of the entire toroidal magnet system. In this paper a model to simulate the fast dump of the ATLAS toroids in single mode operation and in full system configuration is presented. The model is validated through comparison with measured data extracted from the ramp-and-quench runs. The calculated energy dissipation in the various coils is in very good agreement (within 1-2\\%) with the enthalpy changes estimated from the temperature measurements of the different parts of the cold ...

  19. A Novel Supercapacitor/Lithium-Ion Hybrid Energy System with a Fuzzy Logic-Controlled Fast Charging and Intelligent Energy Management System

    Directory of Open Access Journals (Sweden)

    Muhammad Adil Khan

    2018-05-01

    Full Text Available The electric powered wheelchair (EPW is an essential assistive tool for people with serious injuries or disability. This manuscript describes the validation of applied research for reducing the charging time of an electric wheelchair using a hybrid electric system (HES composed of a supercapacitor (SC bank and a lithium-ion battery with a fuzzy logic controller (FLC-based fast charging system for Li-ion batteries and a fuzzy logic-based intelligent energy management system (FLIEMS for controlling the power flow within the HES. The fast charging FLC was designed to drive the voltage difference (Vd among the different cells of a multi-cell battery and the cell voltage (Vc of an individual cell. These parameters (voltage difference and cell voltage were used as input voltages to reduce the charge time and activate a bypass equalization (BPE scheme. BPE was introduced in this paper so that the battery operates within the safe voltage range. For SC/Li-ion HES, the FLIEMS presented in this paper controls the bi-directional power flow to smooth the power extracted from Li-ion batteries. Moreover, a dual active bridge isolated bidirectional DC converter (DAB-IBDC was used for power conversion. The DAB-IBDC presented in this paper has the characteristics of galvanic isolation, and high power conversion efficiency compared to the conventional converter circuits due to the reduced reverse power flow and current stresses.

  20. Methodology for Extraction of Remaining Sodium of Used Sodium Containers

    International Nuclear Information System (INIS)

    Jung, Minhwan; Kim, Jongman; Cho, Youngil; Jeong, Jiyoung

    2014-01-01

    Sodium used as a coolant in the SFR (Sodium-cooled Fast Reactor) reacts easily with most elements due to its high reactivity. If sodium at high temperature leaks outside of a system boundary and makes contact with oxygen, it starts to burn and toxic aerosols are produced. In addition, it generates flammable hydrogen gas through a reaction with water. Hydrogen gas can be explosive within the range of 4.75 vol%. Therefore, the sodium should be handled carefully in accordance with standard procedures even though there is a small amount of target sodium remainings inside the containers and drums used for experiment. After the experiment, all sodium experimental apparatuses should be dismantled carefully through a series of draining, residual sodium extraction, and cleaning if they are no longer reused. In this work, a system for the extraction of the remaining sodium of used sodium drums has been developed and an operation procedure for the system has been established. In this work, a methodology for the extraction of remaining sodium out of the used sodium container has been developed as one of the sodium facility maintenance works. The sodium extraction system for remaining sodium of the used drums was designed and tested successfully. This work will contribute to an establishment of sodium handling technology for PGSFR. (Prototype Gen-IV Sodium-cooled Fast Reactor)

  1. Impact of the Voltage Transients after a Fast Power Abort on the Quench Detection System in the LHC Main Dipole Chain

    CERN Document Server

    Ravaioli, E; Formenti, F; Montabonnet, V; Pojer, M; Schmidt, R; Siemko, A; Solfaroli Camillocci, A; Steckert, J; Thiesen, H; Verweij, A

    2012-01-01

    A Fast Power Abort in the LHC superconducting main dipole circuit consists in the switch-off of the power converter and the opening of the two energy-extraction switches. Each energy-extraction unit is composed of redundant electromechanical breakers, which are opened to force the current through an extraction resistor. When a switch is opened arcing occurs in the switch and a voltage of up to 1 kV builds up across the extraction resistor with a typical ramp rate of about 80 kV/s. The subsequent voltage transient propagates through the chain of 154 dipoles and superposes on the voltage waves caused by the switch-off of the power converter. The resulting effect caused intermittent triggering of the quench protection systems along with heater firings in the magnets when the transient occurred during a ramp of the current. A delay between power converter switch-off and opening of the energy-extraction switches was introduced to prevent this effect. Furthermore, the output filters of the power converters were mod...

  2. Fast reactor knowledge preservation system: Taxonomy and basic requirements

    International Nuclear Information System (INIS)

    2008-01-01

    The IAEA has taken the initiative to coordinate efforts of Member States in the preservation of knowledge in the area of fast reactors. In the framework of this initiative, the IAEA intends to create an international database compiling information from different Member States on fast reactors through a web portal. Other activities related to this initiative are being designed to accumulate and exchange information on the fast reactor area, to facilitate access to this information by users in different countries and to assist Member States in preserving the experience gained in their countries. The purpose of this publication is to develop a taxonomy of the Fast Reactor Knowledge Preservation System (FRKPS) that will facilitate the preservation of the world's fast reactor knowledge base, to identify basic requirements of this taxonomy on the basis of the experience gained in the fast reactor area, as well as results of previous IAEA activities on fast reactor knowledge preservation. The need for such taxonomy arises from the fact that during the past 15 years there has been stagnation in the development of fast reactors in the industrialized countries that were involved, earlier, in intensive development of this area. All studies on fast reactors have been stopped in countries such as Germany, Italy, the United Kingdom and the United States of America and the only work being carried out is related to the decommissioning of fast reactors. Many specialists who were involved in the studies and development work in this area in these countries have already retired or are close to retirement. In countries such as France, Japan and the Russian Federation that are still actively pursuing the evolution of fast reactor technology, the situation is aggravated by the lack of young scientists and engineers moving into this branch of nuclear power

  3. Molecularly imprinted microspheres synthesized by a simple, fast, and universal suspension polymerization for selective extraction of the topical anesthetic benzocaine in human serum and fish tissues.

    Science.gov (United States)

    Sun, Hui; Lai, Jia-Ping; Chen, Fang; Zhu, De-Rong

    2015-02-01

    A simple, fast, and universal suspension polymerization method was used to synthesize the molecularly imprinted microspheres (MIMs) for the topical anesthetic benzocaine (BZC). The desired diameter (10-20 μm) and uniform morphology of the MIMs were obtained easily by changing one or more of the synthesis conditions, including type and amount of surfactant, stirring rate, and ratio of organic to water phase. The MIMs obtained were used as a molecular-imprinting solid-phase-extraction (MISPE) material for extraction of BZC in human serum and fish tissues. The MISPE results revealed that the BZC in these biosamples could be enriched effectively after the MISPE operation. The recoveries of BZC on MIMs cartridges were higher than 90% (n = 3). Finally, an MISPE-HPLC method with UV detection was developed for highly selective extraction and fast detection of trace BZC in human serum and fish tissues. The developed method could also be used for the enrichment and detection of BZC in other complex biosamples.

  4. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    Energy Technology Data Exchange (ETDEWEB)

    Habob, Moinul

    2005-12-15

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design.

  5. MCNPX simulations of fast neutron diagnostics for accelerator-driven systems

    International Nuclear Information System (INIS)

    Habib, Moinul

    2005-12-01

    In accelerator-driven systems, the neutron spectrum will extend all the way up to the incident beam energy, i.e., several hundred MeV or even up to GeV energies. The high neutron energy allows novel diagnostics with a set of measurement techniques that can be used in a sub-critical reactor environment. Such measurements are primarily connected to system safety and validation. This report shows that in-core fast-neutron diagnostics can be employed to monitor changes in the position of incidence of the primary proton beam onto the neutron production target. It has also been shown that fast neutrons can be used to detect temperature-dependent density changes in a liquid lead-bismuth target. Fast neutrons can escape the system via the beam pipe for the incident proton beam. Out-of-core monitoring of these so called back-streaming neutrons could potentially be used to monitor beam changes if the target has a suitable shape. Moreover, diagnostics of back-streaming neutrons might be used for validation of the system design

  6. Accelerated solvent extraction (ASE) - a fast and automated technique with low solvent consumption for the extraction of solid samples (T12)

    International Nuclear Information System (INIS)

    Hoefler, F.

    2002-01-01

    Full text: Accelerated solvent extraction (ASE) is a modern extraction technique that significantly streamlines sample preparation. A common organic solvent as well as water is used as extraction solvent at elevated temperature and pressure to increase extraction speed and efficiency. The entire extraction process is fully automated and performed within 15 minutes with a solvent consumption of 18 ml for a 10 g sample. For many matrices and for a variety of solutes, ASE has proven to be equivalent or superior to sonication, Soxhlet, and reflux extraction techniques while requiring less time, solvent and labor. First ASE has been applied for the extraction of environmental hazards from solid matrices. Within a very short time ASE was approved by the U.S. EPA for the extraction of BNAs, PAHs, PCBs, pesticides, herbicides, TPH, and dioxins from solid samples in method 3545. Especially for the extraction of dioxins the extraction time with ASE is reduced to 20 minutes in comparison to 18 h using Soxhlet. In food analysis ASE is used for the extraction of pesticide and mycotoxin residues from fruits and vegetables, the fat determination and extraction of vitamins. Time consuming and solvent intensive methods for the extraction of additives from polymers as well as for the extraction of marker compounds from herbal supplements can be performed with higher efficiencies using ASE. For the analysis of chemical weapons the extraction process and sample clean-up including derivatization can be automated and combined with GC-MS using an online ASE-APEC-GC system. (author)

  7. SISAK liquid-liquid extraction experiments with preseparated {sup 257}Rf

    Energy Technology Data Exchange (ETDEWEB)

    Omtvedt, Jon Petter; Alstad, J.; Breivik, H. [University of Oslo, Department of Chemistry, Oslo (NO)] (and others)

    2002-06-01

    The SISAK liquid-liquid extraction system was used to extract 4.0-s {sup 257}Rf. The {sup 257}Rf was produced in the reaction {sup 208}Pb({sup 50}Ti, 1n){sup 257}Rf with 237-MeV beam energy on target, separated in the Berkeley Gas-filled Separator (BGS) and transferred to a gas jet using the Recoil Transfer Chamber (RTC). The activity delivered by the gas jet was dissolved in 6-M HNO{sub 3} and Rf was extracted into 0.25-M dibutyl-phosphoric acid in toluene. This was the first time a transactinide, i.e., an element with Z{>=}104, was extracted and unequivocally identified by the SISAK system. Thus, this pilot experiment demonstrates that the fast liquid-liquid extraction system SISAK, in combination with liquid-scintillation detectors, can be used for investigating the chemical properties of the transactinides. The extraction result is in accordance with the behaviour shown by the Rf group IV homologues Zr and Hf. (author)

  8. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Neil Todreas; Pavel Hejzlar

    2008-06-30

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  9. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    International Nuclear Information System (INIS)

    Neil Todreas; Pavel Hejzlar

    2008-01-01

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores treated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcome the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better thermal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor

  10. Fast-track aquifer characterization and bioremediation of groundwater

    International Nuclear Information System (INIS)

    Owen, S.B.; Erskine, J.A.; Adkisson, C.

    1995-01-01

    A short duration step-drawdown pumping test has been used to characterize a highly permeable aquifer contaminated with petroleum hydrocarbons in support of an in situ, closed loop extraction and reinjection bioremediation system for groundwater. The short-term pumping test produces a manageable quantity of contaminated groundwater while yielding a range of values for transmissivity and specific yield parameters. This range of aquifer coefficients is used in an analytical model to estimate a range of groundwater extraction rates that provide a suitable radius of influence for the extraction and reinjection system. A multi-enzyme complex catalyzed bioremediation process has been used to aerobically degrade petroleum hydrocarbons. Enzymes, amino acids, and biosurfactants are supplied to the extracted groundwater to significantly speed up the degradation by naturally occurring bacteria. During the process, amino acids promote the rapid growth of the microbial population while enzymes and bacteria attach to hydrocarbons forming a transformation state complex that degrades to fatty acids, carbon dioxide, and water. This paper presents a case study of a fast-track bioremediation using pumping test data, analytical modeling, and an enzyme technology

  11. Smart Extraction and Analysis System for Clinical Research.

    Science.gov (United States)

    Afzal, Muhammad; Hussain, Maqbool; Khan, Wajahat Ali; Ali, Taqdir; Jamshed, Arif; Lee, Sungyoung

    2017-05-01

    With the increasing use of electronic health records (EHRs), there is a growing need to expand the utilization of EHR data to support clinical research. The key challenge in achieving this goal is the unavailability of smart systems and methods to overcome the issue of data preparation, structuring, and sharing for smooth clinical research. We developed a robust analysis system called the smart extraction and analysis system (SEAS) that consists of two subsystems: (1) the information extraction system (IES), for extracting information from clinical documents, and (2) the survival analysis system (SAS), for a descriptive and predictive analysis to compile the survival statistics and predict the future chance of survivability. The IES subsystem is based on a novel permutation-based pattern recognition method that extracts information from unstructured clinical documents. Similarly, the SAS subsystem is based on a classification and regression tree (CART)-based prediction model for survival analysis. SEAS is evaluated and validated on a real-world case study of head and neck cancer. The overall information extraction accuracy of the system for semistructured text is recorded at 99%, while that for unstructured text is 97%. Furthermore, the automated, unstructured information extraction has reduced the average time spent on manual data entry by 75%, without compromising the accuracy of the system. Moreover, around 88% of patients are found in a terminal or dead state for the highest clinical stage of disease (level IV). Similarly, there is an ∼36% probability of a patient being alive if at least one of the lifestyle risk factors was positive. We presented our work on the development of SEAS to replace costly and time-consuming manual methods with smart automatic extraction of information and survival prediction methods. SEAS has reduced the time and energy of human resources spent unnecessarily on manual tasks.

  12. Attractors of relaxation discrete-time systems with chaotic dynamics on a fast time scale

    International Nuclear Information System (INIS)

    Maslennikov, Oleg V.; Nekorkin, Vladimir I.

    2016-01-01

    In this work, a new type of relaxation systems is considered. Their prominent feature is that they comprise two distinct epochs, one is slow regular motion and another is fast chaotic motion. Unlike traditionally studied slow-fast systems that have smooth manifolds of slow motions in the phase space and fast trajectories between them, in this new type one observes, apart the same geometric objects, areas of transient chaos. Alternating periods of slow regular motions and fast chaotic ones as well as transitions between them result in a specific chaotic attractor with chaos on a fast time scale. We formulate basic properties of such attractors in the framework of discrete-time systems and consider several examples. Finally, we provide an important application of such systems, the neuronal electrical activity in the form of chaotic spike-burst oscillations.

  13. The JET fast central acquisition and trigger system

    International Nuclear Information System (INIS)

    Blackler, K.; Edwards, A.W.

    1994-01-01

    This paper describes a new data acquisition system at JET which uses Texas TMS320C40 parallel digital signal processors and the HELIOS parallel operating system to reduce the large amounts of experimental data produced by fast diagnostics. This unified system features a two level trigger system which performs real-time activity detection together with asynchronous event classification and selection. This provides automated data reduction during an experiment. The system's application to future fusion machines which have almost continuous operation is discussed

  14. Antioxidant Activity of Flaxseed Extracts in Lipid Systems

    Directory of Open Access Journals (Sweden)

    Adriana Slavova-Kazakova

    2015-12-01

    Full Text Available The aim of this work was to compare the antioxidant activity of the extract of flaxseed and its alkaline hydrolysate in two model systems: lipid autoxidation of triacylglycerols of sunflower oil (TGSO—in a homogeneous lipid media and during β-carotene-linoleate emulsion system. In addition, pure lignans were tested. The material was defatted with hexane and then phenolic compounds were extracted using dioxane-ethanol (50:50, v/v mixture. Carbohydrates were removed from the crude extract using an Amberlite XAD-16 column chromatography. The content of total phenolic compounds in the crude extract and after alkaline hydrolysis was determined using a Folin-Ciocalteu’s phenol reagent. Individual phenolic compounds were determined by nordihydroguaiaretic acid (RP-HPLC method in gradient system. The alkaline hydrolysis increased the content of total phenolics in the extract approximately by 10%. In the extracts of flaxseed, phenolic compounds were present in the form of macromolecular complex. In the alkaline hydrolysate, secoisolariciresinol diglucoside (SDG was found as the main phenolic compound. Small amounts of p-coumaric and ferulic acids were also determined. SDG and both extracts were not able to inhibit effectively lipid autoxidation. The kinetics of TGSO autoxidation at 80 °C in absence and in presence of the extract before hydrolysis (EBH and after hydrolysis (EAH was monitored and compared with known standard antioxidants. Ferulic acid (FA and butylated hydroxyl toluene (BHT showed much higher antioxidant efficiency and reactivity than that of both extracts. Secoisolariciresinol (SECO showed a higher activity in both model systems than SDG. However, the activity of SECO was much lower than that of nordihydroquaiaretic acid (NDGA.

  15. Fast infectious diseases diagnostics based on microfluidic biochip system

    Directory of Open Access Journals (Sweden)

    Qin Huang

    2017-03-01

    Full Text Available Molecular diagnostics is one of the most important tools currently in use for clinical pathogen detection due to its high sensitivity, specificity, and low consume of sample and reagent is keyword to low cost molecular diagnostics. In this paper, a sensitive DNA isothermal amplification method for fast clinical infectious diseases diagnostics at aM concentrations of DNA was developed using a polycarbonate (PC microfluidic chip. A portable confocal optical fluorescence detector was specifically developed for the microfluidic chip that was capable of highly sensitive real-time detection of amplified products for sequence-specific molecular identification near the optical diffraction limit with low background. The molecular diagnostics of Listeria monocytogenes with nucleic acid extracted from stool samples was performed at a minimum DNA template concentration of 3.65aM, and a detection limit of less than five copies of genomic DNA. Contrast to the general polymerase chain reaction (PCR at eppendorf (EP tube, the detection time in our developed method was reduced from 1.5h to 45min for multi-target parallel detection, the consume of sample and reagent was dropped from 25μL to 1.45μL. This novel microfluidic chip system and method can be used to develop a micro total analysis system as a clinically relevant pathogen molecular diagnostics method via the amplification of targets, with potential applications in biotechnology, medicine, and clinical molecular diagnostics.

  16. Behavior of 241Am in fast reactor systems - a safeguards perspective

    International Nuclear Information System (INIS)

    Beddingfield, David H.; Lafleur, Adrienne M.

    2009-01-01

    Advanced fuel-cycle developments around the world currently under development are exploring the possibility of disposing of 241 Am from spent fuel recycle processes by burning this material in fast reactors. For safeguards practitioners, this approach could potentially complicate both fresh- and spent-fuel safeguards measurements. The increased (α,n) production in oxide fuels from the 241 Am increases the uncertainty in coincidence assay of Pu in MOX assemblies and will require additional information to make use of totals-based neutron assay of these assemblies. We have studied the behavior of 241 Am-bearing MOX fuel in the fast reactor system and the effect on neutron and gamma-ray source-terms for safeguards measurements. In this paper, we will present the results of simulations of the behavior of 241 Am in a fast breeder reactor system. Because of the increased use of MOX fuel in thermal reactors and advances in fuel-cycle designs aimed at americium disposal in fast reactors, we have undertaken a brief study of the behavior of americium in these systems to better understand the safeguards impacts of these new approaches. In this paper we will examine the behavior of 241 Am in a variety of nuclear systems to provide insight into the safeguards implications of proposed Am disposition schemes.

  17. Direct online extraction and determination by supercritical fluid extraction with chromatography and mass spectrometry of targeted carotenoids from red Habanero peppers (Capsicum chinense Jacq.).

    Science.gov (United States)

    Zoccali, Mariosimone; Giuffrida, Daniele; Dugo, Paola; Mondello, Luigi

    2017-10-01

    Recently, supercritical fluid chromatography coupled to mass spectrometry has gained attention as a fast and useful technology applied to the carotenoids analysis. However, no reports are available in the literature on the direct online extraction and determination by supercritical fluid extraction with chromatography and mass spectrometry. The aim of this research was the development of an online method coupling supercritical fluid extraction and supercritical fluid chromatography for a detailed targeted native carotenoids characterization in red habanero peppers. The online nature of the system, compared to offline approaches, improves run-to-run precision, enables the setting of batch-type applications, and reduces the risks of sample contamination. The extraction has been optimized using different temperatures, starting from 40°C up to 80°C. Multiple extractions, until depletion, were performed on the same sample to evaluate the extraction yield. The range of the first extraction yield, carried out at 80°C, which was the best extraction temperature, was 37.4-65.4%, with a %CV range of 2-12. Twenty-one targeted analytes were extracted and identified by the developed methodology in less than 17 min, including free, monoesters, and diesters carotenoids, in a very fast and efficient way. Quantification of the β-carotene was carried out by using the optimized conditions. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Fast Computation and Assessment Methods in Power System Analysis

    Science.gov (United States)

    Nagata, Masaki

    Power system analysis is essential for efficient and reliable power system operation and control. Recently, online security assessment system has become of importance, as more efficient use of power networks is eagerly required. In this article, fast power system analysis techniques such as contingency screening, parallel processing and intelligent systems application are briefly surveyed from the view point of their application to online dynamic security assessment.

  19. A fast ADC system for silicon μstrips readout

    International Nuclear Information System (INIS)

    Inzani, P.; Pedrini, D.; Sala, S.

    1986-01-01

    A new fast ADC module has been designed. It is part of a large readout system for a high resolution vertex detector consisting of 12 silicon microstrip planes with more than 8000 channels. The module employs a set of monolithic gated integrators on input (LeCroy MIQ 401) multiplexed on a single 8 bit FADC (Thompson EFX8308). A built-in preprocessing, performed through look up tables, accomplishes equalization and reduction of the data and makes high level trigger feasible. As an additional feature, fast histogramming of all the channels in parallel has been made possible with an internal memory. Special care has been paid to realize a low cost and low power consumption system

  20. MPACT Fast Neutron Multiplicity System Prototype Development

    Energy Technology Data Exchange (ETDEWEB)

    D.L. Chichester; S.A. Pozzi; J.L. Dolan; M.T. Kinlaw; S.J. Thompson; A.C. Kaplan; M. Flaska; A. Enqvist; J.T. Johnson; S.M. Watson

    2013-09-01

    This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

  1. Sophistication of burnup analysis system for fast reactor (2)

    International Nuclear Information System (INIS)

    Yokoyama, Kenji; Hirai, Yasushi; Tatsumi, Masahiro

    2010-10-01

    Improvement on prediction accuracy for neutronics characteristics of fast reactor cores is one of the most important study domains in terms of both achievement of high economical plant efficiency based on reasonably advanced designs and increased reliability and safety margins. In former study, considerable improvement on prediction accuracy in neutronics design has been achieved in the development of the unified cross-section set as a fruit of a series of critical experiments such as JUPITER in application of the reactor constant adjustments. For design of fast reactor cores improvement of not only static characteristics but also burnup characteristics is very important. For such purpose, it is necessary to improve the prediction accuracy on burnup characteristics using actual burnup data of 'JOYO' and 'MONJU', experimental and prototype fast reactors. Recently, study on effective burnup method for minor actinides becomes important theme. However, there is a problem that analysis work tends to become inefficient for lack of functionality suitable for analysis of composition change due to burnup since the conventional analysis system is targeted to critical assembly systems. Therefore development of burnup analysis system for fast reactors with modularity and flexibility is being done that would contribute to actual core design work and improvement of prediction accuracy. In the previous study, we have developed a prototype system which has functions of performing core and burnup calculations using given constant files (PDS files) and information based on simple and easy user input data. It has also functions of fuel shuffling which is indispensable for power reactor analysis systems. In the present study, by extending the prototype system, features for handling of control rods and energy collapse of group constants have been designed and implemented. Computational results from the present analysis system are stored into restart files which can be accessible by

  2. Technical Meeting on Passive Shutdown Systems for Liquid Metal-Cooled Fast Reactors. Working Material

    International Nuclear Information System (INIS)

    2015-01-01

    A major focus of the design of modern fast reactor systems is on inherent and passive safety. Specific systems to improve reactor safety performance during accidental transients have been developed in nearly all fast reactor programs, and a large number of proposed systems have reached various stages of maturity. This Technical Meeting on Passive Shutdown Systems for Fast Reactors, which was recommended by the Technical Working Group on Fast Reactors (TWG-FR), addressed Member States’ expressed need for information exchange on projects and programs in the field, as well as for the identification of priorities based on the analysis of technology gaps to be covered through R&D activities. This meeting was limited to shutdown systems only, and did not include other passive features such as natural circulation decay heat removal systems etc.; however the meeting catered to passive shutdown safety devices applicable to all types of fast neutron systems. It was agreed to initiate a new study and produce a Nuclear Energy Series (NES) Technical Report to collect information about the existing operational systems as well as innovative concepts under development. This will be a useful source for member states interested in gaining technical expertise to develop passive shutdown systems as well as to highlight the importance and development in this area

  3. Validation experiments of nuclear characteristics of the fast-thermal system HERBE

    International Nuclear Information System (INIS)

    Pesic, M.; Zavaljevski, N.; Marinkovic, P.; Stefanovis, D.; Nikolic, D.; Avdic, S.

    1992-01-01

    In 1988/90 a coupled fast-thermal system HERBE at RB reactor, based on similar facilities, is designed and realized. Fast core of HERBE is built of natural U fuel in RB reactor center surrounded by the neutron filter and neutron converter located in an independent Al tank. Fast zone is surrounded by thermal neutron core driver. Designed nuclear characteristics of HERBE core are validated in the experiments described in the paper. HERBE cell parameters were calculated with developed computer codes: VESNA and DENEB. HERBE system criticality calculation are performed with 4G 2D RZ computer codes GALER and TWENTY GRAND, 1D multi-group AVERY code and 3D XYZ few-group TRITON computer code. The experiments for determination of critical level, dρ/dH, and reactivity of safety rods are accomplished in order to validate calculation results. Specific safety experiment is performed in aim to determine reactivity of flooded fast zone in possible accident. A very good agreements with calculation results are obtained and the validation procedures are presented. It is expected that HERBE will offer qualitative new opportunities for work with fast neutrons at RB reactor including nuclear data determination. (author)

  4. Fast Flux Test Facility core system

    International Nuclear Information System (INIS)

    Ethridge, J.L.; Baker, R.B.; Leggett, R.D.; Pitner, A.L.; Waltar, A.E.

    1990-11-01

    A review of Liquid Metal Reactor (LMR) core system accomplishments provides an excellent road map through the maze of issues that faced reactor designers 10 years ago. At that time relatively large uncertainties were associated with fuel pin and fuel assembly performance, irradiation of structural materials, and performance of absorber assemblies. The extensive core systems irradiation program at the US Department of Energy's Fast Flux Test Facility (FFTF) has addressed each of these principal issues. As a result of the progress made, the attention of long-range LMR planners and designers can shift away from improving core systems and focus on reducing capital costs to ensure the LMR can compete economically in the 21st century with other nuclear reactor concepts. 3 refs., 6 figs., 1 tab

  5. Fast multichannel analog storage system

    International Nuclear Information System (INIS)

    Freytag, D.R.

    1982-11-01

    A Multichannel Analog Storage System based on a commercial 32-channel parallel in/serial out (PISO) analog shift register is described. The basic unit is a single width CAMAC module containing 512 analog cells and the associated logic for data storage and subsequent readout. At sampling rates of up to 30 MHz the signals are strobed directly into the PISO. At higher rates signals are strobed into a fast presampling stage and subsequently transferred in block form into an array of PISO's. Sampling rates of 300 MHz have been achieved with the present device and 1000 MHz are possible with improved signal drivers. The system is well suited for simultaneous handling of many signal channels with moderate numbers of samples in each channel. RMS noise over full scale signal has been measured as 1:3000 (approx. = 11 bit). However, nonlinearities in the response and differences in sensitivity of the analog cells require an elaborate calibration system in order to realize 11 bit accuracy for the analog information

  6. Extraction of Trivalent Actinides and Lanthanides from Californium Campaign Rework Solution Using TODGA-based Solvent Extraction System

    Energy Technology Data Exchange (ETDEWEB)

    Benker, Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Delmau, Laetitia Helene [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dryman, Joshua Cory [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-07-01

    This report presents the studies carried out to demonstrate the possibility of quantitatively extracting trivalent actinides and lanthanides from highly acidic solutions using a neutral ligand-based solvent extraction system. These studies stemmed from the perceived advantage of such systems over cationexchange- based solvent extraction systems that require an extensive feed adjustment to make a low-acid feed. The targeted feed solutions are highly acidic aqueous phases obtained after the dissolution of curium targets during a californium (Cf) campaign. Results obtained with actual Cf campaign solutions, but highly diluted to be manageable in a glove box, are presented, followed by results of tests run in the hot cells with Cf campaign rework solutions. It was demonstrated that a solvent extraction system based on the tetraoctyl diglycolamide molecule is capable of quantitatively extracting trivalent actinides from highly acidic solutions. This system was validated using actual feeds from a Cf campaign.

  7. Extraction systems for the study of dubnium

    International Nuclear Information System (INIS)

    Gates, J.M.; Sudowe, R.; Ali, M.N.; Calvert, M.G.; Dragojevic, I.; Ellison, P.A.; Garcia, M.A.; Gharibyan, N.; Gregorich, K.E.; Nelson, S.L.; Neumann, S.H.; Parsons-Moss, T.; Stavsetra, L.; Nitsche, H.

    2007-01-01

    The chemistry of transactinide elements (Z (ge) 104) is a topic of great interest in current nuclear chemistry research. The chemical systems that can be used in these studies are limited by the short half-lives of the isotopes and the small production rates of atoms per minute or even atoms per week. In the initial investigations, the chemistry used had to be very selective to the periodic group of interest to separate the transactinide atom from all the other unwanted nuclear reaction products, e.g., transfer products. By using the Berkeley Gas-filled Separator (BGS) as a physical pre-separator, we are able concentrate on systems that are selective between the members of the group of interest, because all other interfering products and the beam are being suppressed by the BGS [1]. We are developing suitable extraction systems for the study of element 105, dubnium. For this purpose we have studied the extraction of niobium and tantalum, the lighter homologs of dubnium, from mineral acids with different organophosphorus compounds. All studies were performed online, using short-lived niobium and tantalum produced in the 124 Sn( 51 V,5n) 170 Ta and 74 Se( 18 O,p3n) 88 Nb reactions. This allowed for the study of the lighter homologues at metal concentrations of 10 -16 M. At these low metal concentrations, the formation of polymeric species is largely prohibited. As seen in Fig. 1, by varying the extractant and the hydrochloric acid concentration from 1 to 11 M, we are able to see a difference in extraction behavior between niobium and tantalum. While the system is suitable for determining chemical differences between the lighter homologues, the extraction of tantalum from hydrochloric acid shows slow kinetics. Figure 2 shows that after 90 seconds of mixing, the system is not in equilibrium. However, experiments indicate that equilibrium is reached faster at higher acid concentrations. We have studied the influence of hydrogen ion concentration on the extraction

  8. Accelerator Technology: Injection and Extraction Related Hardware: Kickers and Septa

    CERN Document Server

    Barnes, M J; Mertens, V

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the the Section '8.7 Injection and Extraction Related Hardware: Kickers and Septa' of the Chapter '8 Accelerator Technology' with the content: 8.7 Injection and Extraction Related Hardware: Kickers and Septa 8.7.1 Fast Pulsed Systems (Kickers) 8.7.2 Electrostatic and Magnetic Septa

  9. NetCDF based data archiving system applied to ITER Fast Plant System Control prototype

    International Nuclear Information System (INIS)

    Castro, R.; Vega, J.; Ruiz, M.; De Arcas, G.; Barrera, E.; López, J.M.; Sanz, D.; Gonçalves, B.; Santos, B.; Utzel, N.; Makijarvi, P.

    2012-01-01

    Highlights: ► Implementation of a data archiving solution for a Fast Plant System Controller (FPSC) for ITER CODAC. ► Data archiving solution based on scientific NetCDF-4 file format and Lustre storage clustering. ► EPICS control based solution. ► Tests results and detailed analysis of using NetCDF-4 and clustering technologies on fast acquisition data archiving. - Abstract: EURATOM/CIEMAT and Technical University of Madrid (UPM) have been involved in the development of a FPSC (Fast Plant System Control) prototype for ITER, based on PXIe (PCI eXtensions for Instrumentation). One of the main focuses of this project has been data acquisition and all the related issues, including scientific data archiving. Additionally, a new data archiving solution has been developed to demonstrate the obtainable performances and possible bottlenecks of scientific data archiving in Fast Plant System Control. The presented system implements a fault tolerant architecture over a GEthernet network where FPSC data are reliably archived on remote, while remaining accessible to be redistributed, within the duration of a pulse. The storing service is supported by a clustering solution to guaranty scalability, so that FPSC management and configuration may be simplified, and a unique view of all archived data provided. All the involved components have been integrated under EPICS (Experimental Physics and Industrial Control System), implementing in each case the necessary extensions, state machines and configuration process variables. The prototyped solution is based on the NetCDF-4 (Network Common Data Format) file format in order to incorporate important features, such as scientific data models support, huge size files management, platform independent codification, or single-writer/multiple-readers concurrency. In this contribution, a complete description of the above mentioned solution is presented, together with the most relevant results of the tests performed, while focusing in the

  10. Real Time Extraction Kinetics of Electro Membrane Extraction Verified by Comparing Drug Metabolism Profiles Obtained from a Flow-Flow Electro Membrane Extraction-Mass Spectrometry System with LC-MS

    DEFF Research Database (Denmark)

    Fuchs, David; Jensen, Henrik; Pedersen-Bjergaard, Stig

    2015-01-01

    A simple to construct and operate, "dip-in" electromembrane extraction (EME) probe directly coupled to electrospray ionization-mass spectrometry (ESI-MS) for rapid extraction and real time analysis of various analytes was developed. The setup demonstrated that EME-MS can be used as a viable...... alternative to conventional protein precipitation followed by liquid chromatography-mass spectrometry (LC-MS) for studying drug metabolism. Comparison of EME-MS with LC-MS for drug metabolism analysis demonstrated for the first time that real time extraction of analytes by EME is possible. Metabolism kinetics...... offering a significant time saving as compared to conventional LC-MS where laborious protein precipitation or other sample pretreatments are required before analysis. This makes the developed EME-MS setup a highly promising sample preparation method for various kinds of applications where fast and real-time...

  11. 1.5 GeV/c multiturn shaving extraction and its transport line for the Brookhaven AGS

    International Nuclear Information System (INIS)

    Weng, W.T.; Blumberg, L.N.; Gill, E.; Soukas, A.; Witkover, R.L.; Egleman, E.; LoSecco, J.; Sulak, L.

    1979-01-01

    A system for fast shaving extraction at 1.5 GeV/c is implemented to extract the circulating beam in five turns. A numerical simulation is first carried out to determine the emittance and the rf structure of the extracted beam. This is followed by several machine study sessions which establish the optimal extraction configuration, confirm the emittance, and modify the transport line for low energy beam. Finally, a one-week run for the Neutrino Oscillation experiment demonstrates that the system is very stable and capable of delivering 7.5 x 10 12 p/sec with 70% extraction efficiency and 95% transport efficiency

  12. Electron beam extraction from a HVPES

    International Nuclear Information System (INIS)

    Marghitu, S.; Cramariuc, R.; Nicolescu, I.; Niculescu, M.

    1996-01-01

    The results of the research concerning the extraction system of the fast electrons from a cold cathode high voltage glow discharge plasma electron source (HVPES) are presented. For using the electron beam in a more flexible way, that is changing the shape of the minimum cross-section, (or beam cross-over), of the beam in a sample S frontal plane, without perturbing the discharge parameters, some modifications to a reference internal geometry were tested. Finally, a geometry was found in which the discharge volume may be separated in two parts, one, 'a discharge space', filled with plasma and fast electrons and another, 'working space', occupied specially by the fast electron beam. In this new geometry the electrical discharge parameters, I d - discharge current, U d - discharge voltage, were the same as for the reference geometry. (authors)

  13. Design of Measurement and Control System of Composite Fast Transfer Switch Based on PLC

    Directory of Open Access Journals (Sweden)

    ZHANG Hong-yi

    2017-06-01

    Full Text Available The fast transfer switch gets more extensive application in the power supply system along with the raising of power supply requirement for continuity and reliability in the sensitivity loads such as in airport,military place,hospital and large scale industrial production line. Therefore it is important that how to make fast transfer switch run safely and reliably. The paper expatiated the structure and principle of a fast transfer switch based on mechanical and electronic compound technology,and,according to the basic requirement and the characteristic of the fast transfer switch,a PLC mastered measuring and controlling system has been designed to raise the operation reliability of the fast transfer switch.

  14. Concept design of divertor remote handling system for the FAST machine

    Energy Technology Data Exchange (ETDEWEB)

    Di Gironimo, G., E-mail: giuseppe.digironimo@unina.it [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Labate, C.; Renno, F. [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Brolatti, G.; Crescenzi, F.; Crisanti, F. [CR ENEA Frascati, Via E. Fermi 27, Frascati (RM) (Italy); Lanzotti, A. [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Lucca, F. [LT Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Siuko, M. [VTT Systems Engineering, Tekniikankatu 1, 33720 Tampere (Finland)

    2013-10-15

    The paper presents a concept design of a remote handling (RH) system oriented to maintenance operations on the divertor second cassette in FAST, a satellite of ITER tokamak. Starting from ITER configuration, a suitably scaled system, composed by a cassette multifunctional mover (CMM) connected to a second cassette end-effector (SCEE), can represent a very efficient solution for FAST machine. The presence of a further system able to open the divertor port, used for RH aims, and remove the first cassette, already aligned with the radial direction of the port, is presumed. Although an ITER-like system maintains essentially shape and proportions of its reference configuration, an appropriate arrangement with FAST environment is needed, taking into account new requirements due to different dimensions, weights and geometries. The use of virtual prototyping and the possibility to involve a great number of persons, not only mechanical designers but also physicist, plasma experts and personnel assigned to remote handling operations, made them to share the multiphysics design experience, according to a concurrent engineering approach. Nevertheless, according to the main objective of any satellite tokamak, such an approach benefits the study of enhancements to ITER RH system and the exploration of alternative solutions.

  15. Fast optical measurements and imaging of flow mixing: Fast optical measurements and imaging of temperature in combined fossil fuel and biomass/waste systems

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Soennik; Fateev, A.; Lindorff Nielsen, K.; Evseev, V.

    2012-02-15

    Project is focused on fast time-resolved infrared measurements of gas temperature and fast IR-imagining of flames in various combustion environments. The infrared spectrometer system was developed in the project for fast infrared spectral measurements on industrial scale using IR-fibre- optics. Fast time-and spectral-resolved measurements in 1.5-5.1 mu spectral range give information about flame characteristics like gas and particle temperatures, eddies and turbulent gas mixing. Time-resolved gas composition in that spectral range (H{sub 2}O, CH{sub 4}, CO{sub 2}, CO) which is one of the key parameters in combustion enhancement can be also obtained. The infrared camera was also used together with special endoscope optics for fast thermal imaging of a coal-straw flame in an industrial boiler. Obtained time-resolved infrared images provided useful information for the diagnostics of the flame and fuel distribustion. The applicability of the system for gas leak detection is also demonstrated. The infrared spectrometer system with minor developments was applied for fast time-resolved exhaust gas temperature measurements performed simultaneously at the three optical ports of the exhaust duct of a marine Diesel engine and visualisation of gas flow behaviour in cylinder. (Author)

  16. Fast reactor sodium systems operation experience and 'leak-before-break' criterion

    International Nuclear Information System (INIS)

    Ivanenko, V.N.; Zybin, V.A.

    1996-01-01

    In the paper sodium leakage detection systems used at fast reactors are described. Requirements on their main characteristics (sensitivity, response lime) are formulated. Results of tests are presented on studying the parameters of sodium leak detection systems including experiments on the measurement of size distribution of aerosol particles that have passed through sodium systems thermal insulation after leak initiation. Comparison of these data with dispersion of particles formed at free burning is carried out. Experience of real leaks that occurred at fast reactor sodium systems is analyzed. It has been shown that initiation and development of real leaks do not always follow the theoretical scheme. A substantial role of human factor for sodium systems reliability relative to sodium leaks is stressed. (author)

  17. Development of lab scale fast gas injection system for SST-1 Tokamak

    International Nuclear Information System (INIS)

    Pathan, F.S.; Banaudha, Moni; Khristi, Yohan; Khan, M.S.; Khan, Ziauddin; Raval, D.C.; Khirwadkar, Samir

    2017-01-01

    The plasma density control plays an important role in Tokamak operation. The factors that influence plasma density in a Tokamak device are working gas injection, pumping, ionization rate and the recycle coefficient representing the wall conditions. Among these factors, gas injection is relatively convenient to be controlled. Hence, the most frequently adopted method to control the plasma density is to control the fast gas injection. This paper describes the design and experimental work carried out towards the development of Fast Gas Injection System for SST-1 Tokamak. Laboratory based test setup was successfully established for Fast Gas Injection System that can feed predefined quantity of gas in a controlled manner into vacuum chamber. Further, this FGIS system will be implemented in SST-1 Tokamak environment with online density feedback signal

  18. New Fast Beam Conditions Monitoring (BCM1F) system for CMS

    Science.gov (United States)

    Zagozdzinska, A. A.; Bell, A. J.; Dabrowski, A. E.; Hempel, M.; Henschel, H. M.; Karacheban, O.; Przyborowski, D.; Leonard, J. L.; Penno, M.; Pozniak, K. T.; Miraglia, M.; Lange, W.; Lohmann, W.; Ryjov, V.; Lokhovitskiy, A.; Stickland, D.; Walsh, R.

    2016-01-01

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure.

  19. LHC beam dumping system Extraction channel layout and acceptance

    CERN Document Server

    Goddard, B; Uythoven, J; Veness, R; Weterings, W

    2003-01-01

    The LHC beam dumping system must safely abort the LHC beams under all conditions, including those resulting from abnormal behaviour of machine elements or subsystems of the beam dumping system itself. The extraction channels must provide sufficient aperture both for the circulating and extracted beams, over the whole energy range and under various beam parameters. These requirements impose tight constraints on the tolerances of various extraction channel components, and also on the allowed range of beam positions in the region of these components. Operation of the beam dumping system under various fault states has been considered, and the resulting apertures calculated. After describing briefly the beam dumping system and the extraction channel geometry, the various assumptions made in the analysis are presented, before deriving tolerance limits for the relevant equipment and beam parameters.

  20. The feasibility study on commercialized fast reactor cycle system

    International Nuclear Information System (INIS)

    Noda, Hiroshi

    2002-01-01

    The feasibility study on commercialized Fast Reactor cycle system (FS) has been carried out by a joint team with the participation of all parties concerned in Japan since July, 1999. It aims to clarify various perspectives for commercialized fast reactor cycle system and also suggest development strategies to diverse social needs in the 21 st century. The FS consists of several phases. The phase 1 has progressed as planned and the highly feasible candidate concepts with innovative technologies have been screened out among a wide variety of concepts. During the phase 2, approximately five years after the phase 1, the in-depth design studies and engineering scale tests of key technologies are being conducted to verify and validate the feasibility of screened candidate concepts. At the end of the phase 2, a few promising concepts will be selected with their R and D tasks. The paper describes the results of the phase 1, the activities of the phase 2 and the new concept related to the fast reactor fuel cycle focusing on the reduction in environmental burden, which is one of key factors to sustain the nuclear power generation in the 21 st century

  1. Determination of the phosphorylated sugars of the Embden-Meyerhoff-Parnas Pathway in Lactococcus lactis using a fast sampling technique and solid phase extraction

    DEFF Research Database (Denmark)

    Jensen, Niels B.s.; Jokumsen, Kirsten Væver; Villadsen, John

    1999-01-01

    with chloroform at -25 degrees C ensures a total permeability of the cellular membrane towards the metabolites of interest as well as the inactivation of enzymes liable to alter their levels. The final step of the procedure consists in a solid phase extraction using columns with a high affinity for phosphorylated...... to -35 degrees C, bringing about a fast and complete stop of all metabolic activity. In contrast to yeast the metabolites leak out of the cells when these are brought into contact with methanol and are present in the medium and in the biomass after the quenching. A liquid-liquid extraction...

  2. Study on the extraction of rare earth elements in liquid bismuth

    International Nuclear Information System (INIS)

    Harada, M.; Adachi, M.; Kai, Y.; Koike, K.

    1987-01-01

    Three factors, which are important for the extraction of rare earth elements in liquid bismuth - molten salt system, were studied, i. e., the equilibrium distribution of neodymium, samarium and bismuth between molten LiCl - liquid Bi-Li alloys, the extraction rate of rare earths, and the characteristics of the extractor with drop dispersion. The rare earth elements were extracted through redox reactions. In high range of Li-mole fraction in the alloy phase, X Li , the distribution of neodymium and bismuth in the salt phase markedly increased as X Li increased. The anomalous increase is attributed to the formation of the compound comprised of Nd, Li, Bi and oxygen in the salt phase. The redox reaction processes were very fast and the extraction rates for rare earths are controlled by the diffusion processes of the solute and the metallic lithium. The process for the formation of liquid metal drops in the continuous phase is predictable from semiempirical correlations reported for aqueous solution - organic solvent systems. The height of droplet bed being accumulated on drop settling portion is predictable from the coalescence time of single drop to a flat metal interface. The coalescence of metal drop to clean interface was very fast. The extractor type of liquid metal dispersion in molten salt is suitable for the extraction process in the fuel reprocessing of MSR or MSBR. (author)

  3. In-Pile Qualification of the Fast-Neutron-Detection-System

    Science.gov (United States)

    Fourmentel, D.; Villard, J.-F.; Destouches, C.; Geslot, B.; Vermeeren, L.; Schyns, M.

    2018-01-01

    In order to improve measurement techniques for neutron flux assessment, a unique system for online measurement of fast neutron flux has been developed and recently qualified in-pile by the French Alternative Energies and Atomic Energy Commission (CEA) in cooperation with the Belgian Nuclear Research Centre (SCK•ECEN). The Fast-Neutron-Detection-System (FNDS) has been designed to monitor accurately high-energy neutrons flux (E > 1 MeV) in typical Material Testing Reactor conditions, where overall neutron flux level can be as high as 1015 n.cm-2.s-1 and is generally dominated by thermal neutrons. Moreover, the neutron flux is coupled with a high gamma flux of typically a few 1015 γ.cm-2.s-1, which can be highly disturbing for the online measurement of neutron fluxes. The patented FNDS system is based on two detectors, including a miniature fission chamber with a special fissile material presenting an energy threshold near 1 MeV, which can be 242Pu for MTR conditions. Fission chambers are operated in Campbelling mode for an efficient gamma rejection. FNDS also includes a specific software that processes measurements to compensate online the fissile material depletion and to adjust the sensitivity of the detectors, in order to produce a precise evaluation of both thermal and fast neutron flux even after long term irradiation. FNDS has been validated through a two-step experimental program. A first set of tests was performed at BR2 reactor operated by SCK•CEN in Belgium. Then a second test was recently completed at ISIS reactor operated by CEA in France. FNDS proved its ability to measure online the fast neutron flux with an overall accuracy better than 5%.

  4. Random Forest Based Coarse Locating and KPCA Feature Extraction for Indoor Positioning System

    Directory of Open Access Journals (Sweden)

    Yun Mo

    2014-01-01

    Full Text Available With the fast developing of mobile terminals, positioning techniques based on fingerprinting method draw attention from many researchers even world famous companies. To conquer some shortcomings of the existing fingerprinting systems and further improve the system performance, on the one hand, in the paper, we propose a coarse positioning method based on random forest, which is able to customize several subregions, and classify test point to the region with an outstanding accuracy compared with some typical clustering algorithms. On the other hand, through the mathematical analysis in engineering, the proposed kernel principal component analysis algorithm is applied for radio map processing, which may provide better robustness and adaptability compared with linear feature extraction methods and manifold learning technique. We build both theoretical model and real environment for verifying the feasibility and reliability. The experimental results show that the proposed indoor positioning system could achieve 99% coarse locating accuracy and enhance 15% fine positioning accuracy on average in a strong noisy environment compared with some typical fingerprinting based methods.

  5. Fast automatic system for measurements of beam parameters of the MMF linac

    International Nuclear Information System (INIS)

    Reinhardt-Nickulin, P.; Bragin, S.; Ilinsky, N.; Senichev, Yu.

    1992-01-01

    Fast transverse beam profile and current monitoring systems have been tested at the Linear Accelerator of Moscow Meson Factory. The signals for each system are derived from multiwire secondary emission chamber and beam current transformer. Each beam pulse is digitized by fast ADC's. There are two modes for systems. First one is for detailed beam adjustment and second one is for normal 100 Hz rate of the MMF Linac. Essential features of the hardware, software, data acquisition, measurement accuracy and beam results are presented. (author)

  6. Fast control and data acquisition in the neutral beam test facility

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.

    2014-01-01

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution

  7. Fast control and data acquisition in the neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.

    2014-05-15

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution.

  8. Fast-Valving of Large Steam Turbine Units as a Means of Power System Security Enhancement

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in an adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of a power system in the presence of an increase in wind and solar generation in the power system, newly connected large thermal units and delaying of building new transmission lines. The principle of fast-valving and advantages of applying this technique in large steam turbine units was presented in the paper. Effectiveness of fast-valving in enhancing the stability of the Polish Power Grid was analyzed. The feasibility study of fast-valving application in the 560 MW unit in Kozienice Power Station (EW SA was discussed.

  9. Development of data acquisition system for tracing fast flow using GPIB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications.

  10. Development of data acquisition system for tracing fast flow using GPIB

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications

  11. The ATLAS Fast Tracker system

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00353645; The ATLAS collaboration

    2017-01-01

    From 2010 to 2012 the Large Hadron Collider (LHC) operated at a centre-of-mass energy of 7 TeV and 8 TeV, colliding bunches of particles every 50 ns. During operation, the ATLAS trigger system has performed efficiently contributing to important results, including the discovery of the Higgs boson in 2012. The LHC restarted in 2015 and will operate for four years at a center of mass energy of 13 TeV and bunch crossing of 50 ns and 25 ns. These running conditions result in the mean number of overlapping proton-proton interactions per bunch crossing increasing from 20 to 60. The Fast Tracker (FTK) system is designed to deliver full event track reconstruction for all tracks with transverse momentum above 1 GeV at a Level-1 rate of 100 kHz with an average latency below 100 microseconds. This will allow the trigger to utilize tracking information from the entire detector at an earlier event selection stage than ever before, allowing for more efficient event rejection. To achieve this goal the system uses a parallel ...

  12. DESIGNING AN EVENT EXTRACTION SYSTEM

    Directory of Open Access Journals (Sweden)

    Botond BENEDEK

    2017-06-01

    Full Text Available In the Internet world, the amount of information available reaches very high quotas. In order to find specific information, some tools were created that automatically scroll through the existing web pages and update their databases with the latest information on the Internet. In order to systematize the search and achieve a result in a concrete form, another step is needed for processing the information returned by the search engine and generating the response in a more organized form. Centralizing events of a certain type is useful first of all for creating a news service. Through this system we are pursuing a knowledge - events from the Internet documents - extraction system. The system will recognize events of a certain type (weather, sports, politics, text data mining, etc. depending on how it will be trained (the concept it has in the dictionary. These events can be provided to the user, or it can also extract the context in which the event occurred, to indicate the initial form in which the event was embedded.

  13. Fast MR imaging for evaluating the pancreaticobiliary system

    International Nuclear Information System (INIS)

    Takehara, Yasuo

    1999-01-01

    Due to physiological movement clinical MR applications for abdominal organs got off to a very slow start compared to MR imaging of other organs. However, with recent cutting-edge hardware technologies such as high performance gradient systems and phased-array capability, as well as software innovations including short TR fast spoiled gradient recalled acquisition in the steady state (GRASS), snapshot imaging such as single shot fast spin echo sequence (SSFSE) and echo planar imaging (EPI), scan times have been further reduced to make breath-hold imaging clinically viable and to enable semi-fluoroscopic, kinematic imaging recognition. The elimination of physiological motion has contributed to the significant improvement in image quality, or more specifically, the physiological motion that had long been problematic has been turned into a source of physiological information about pancreaticobiliary pathologies. In this article, the author reviewed the current status of fast MR technologies for examining pancreaticobiliary pathologies, stressing the functional and physiological aspects of the corresponding anatomy. The technologies included secretin MRCP, which became a powerful tool when combined with kinematic imaging

  14. Fast digital feedback control systems for accelerator RF system using FPGA

    International Nuclear Information System (INIS)

    Bagduwal, Pritam Singh; Sharma, Dheeraj; Tiwari, Nitesh; Lad, M.; Hannurkar, P.R.

    2012-01-01

    Feedback control system plays important role for proper injection and acceleration of beam in particle accelerators by providing the required amplitude and phase stability of RF fields in accelerating structures. Advancement in the field of digital technology enables us to develop fast digital feedback control system for RF applications. Digital Low Level RF (LLRF) system offers the inherent advantages of Digital System like flexibility, adaptability, good repeatability and reduced long time drift errors compared to analog system. To implement the feedback control algorithm, I/Q control scheme is used. By properly sampling the down converted IF signal using fast ADC we get accurate feedback signal and also eliminates the need of two separate detectors for amplitude and phase detection. Controller is implemented in Vertex-4 FPGA. Codes for control algorithms which controls the amplitude and phase in all four quadrants with good accuracy are written in the VHDL. I/Q modulator works as common actuator for both amplitude and phase correction. Synchronization between RF, LO and ADC clock is indispensable and has been achieved by deriving the clock and LO signal from RF signal itself. Control system has been successfully tested in lab with phase and amplitude stability better then ±1% and ±1° respectively. High frequency RF signal is down converted to IF using the super heterodyne technique. Super heterodyne principal not only brings the RF signal to the Low IF frequency at which it can be easily processed but also enables us to use the same hardware and software for other RF frequencies with some minor modification. (author)

  15. Glucocorticoids activate the ATP-ubiquitin-dependent proteolytic system in skeletal muscle during fasting

    Science.gov (United States)

    Wing, S. S.; Goldberg, A. L.; Goldberger, A. L. (Principal Investigator)

    1993-01-01

    Glucocorticoids are essential for the increase in protein breakdown in skeletal muscle normally seen during fasting. To determine which proteolytic pathway(s) are activated upon fasting, leg muscles from fed and fasted normal rats were incubated under conditions that block or activate different proteolytic systems. After food deprivation (1 day), the nonlysosomal ATP-dependent process increased by 250%, as shown in experiments involving depletion of muscle ATP. Also, the maximal capacity of the lysosomal process increased 60-100%, but no changes occurred in the Ca(2+)-dependent or the residual energy-independent proteolytic processes. In muscles from fasted normal and adrenalectomized (ADX) rats, the protein breakdown sensitive to inhibitors of the lysosomal or Ca(2+)-dependent pathways did not differ. However, the ATP-dependent process was 30% slower in muscles from fasted ADX rats. Administering dexamethasone to these animals or incubating their muscles with dexamethasone reversed this defect. During fasting, when the ATP-dependent process rises, muscles show a two- to threefold increase in levels of ubiquitin (Ub) mRNA. However, muscles of ADX animals failed to show this response. Injecting dexamethasone into the fasted ADX animals increased muscle Ub mRNA within 6 h. Thus glucocorticoids activate the ATP-Ub-dependent proteolytic pathway in fasting apparently by enhancing the expression of components of this system such as Ub.

  16. Injection and extraction techniques in circular accelerators

    International Nuclear Information System (INIS)

    Tang Jingyu

    2008-01-01

    Injection and extraction are usually the key systems in circular accelerators. They play important roles in transferring the beam from one stage acceleration to the other or to experimental stations. It is also in the injection and extraction regions where beam losses happen mostly. Due to the tight space and to reduce the perturbation to the circulating orbit, the devices are usually designed to meet special requirements such as compactness, small stray field, fast rise time or fall time, etc. Usual injection and extraction devices include septum magnets, kicker magnets, electrostatic deflectors, slow bump magnets and strippers. In spite of different accelerators and specification for the injection and extraction devices, many techniques are shared in the design and manufacturing. This paper gives a general review on the techniques employed in the major circular accelerators in China. (authors)

  17. A fast and accurate surface plasmon resonance system

    Science.gov (United States)

    Espinosa Sánchez, Y. M.; Luna Moreno, D.; Noé Arias, E.; Garnica Campos, G.

    2012-10-01

    In this work we propose a Surface Plasmon Resonance (SPR) system driven by Labview software which produces a fast, simple and accuracy measurements of samples. The system takes 2000 data in a range of 20 degrees in 20 seconds and 0.01 degrees of resolution. All the information is sent from the computer to the microcontroller as an array of bytes in hexadecimal format to be analyzed. Besides to using the system in SPR measurement is possible to make measurement of the critic angle, and Brewster angle using the Abeles method.

  18. The New SPS Extraction Channel for LHC and CNGS

    CERN Document Server

    Goddard, B; Schröder, G; Weterings, W; Uythoven, J

    2000-01-01

    The Large Hadron Collider (LHC) and CERN Neutrino to Gran Sasso (CNGS) projects require the construction of a new fast-extraction system in the long straight section LSS4 of the Super Proton Synchrotron (SPS) at CERN. A conventional DC septum magnet will be used, in conjunction with the installation of horizontal and vertical extraction bumpers, main quadrupoles with enlarged apertures, extraction kicker magnets and additional hardware protection, instrumentation, controls and electronics. The extraction channel must be able to accept the bright LHC proton beam at 450 GeV/c, and also the high intensity, large emittance fixed target CNGS proton beam at the nominal 400 GeV/c extraction momentum. This paper describes the extraction channel to be installed in 2003, and shows how the requirements for both the LHC and CNGS project can be met.

  19. Experimental Methods Related to Coupled Fast-Thermal Systems at the RB Reactor

    International Nuclear Information System (INIS)

    Pesic, M.

    2002-01-01

    In addition to the review of RB reactor characteristics this presentation is focused on the coupled fast-thermal systems achieved at the reactor. The following experimental methods are presented: neutron spectra measurements; steady state experiments and kinetic measurements ( β eff ) related to the coupled fast-thermal cores

  20. Comparison of RNA extraction methods from biofilm samples of Staphylococcus epidermidis

    Directory of Open Access Journals (Sweden)

    França Angela

    2011-12-01

    Full Text Available Abstract Background Microbial biofilms are communities of bacteria adhered to a surface and surrounded by an extracellular polymeric matrix. Biofilms have been associated with increased antibiotic resistance and tolerance to the immune system. Staphylococcus epidermidis is the major bacterial species found in biofilm-related infections on indwelling medical devices. Obtaining high quality mRNA from biofilms is crucial to validate the transcriptional measurements associated with the switching to the biofilm mode of growth. Therefore, we selected three commercially available RNA extraction kits with distinct characteristics, including those using silica membrane or organic extraction methods, and enzymatic or mechanical cell lysis, and evaluated the RNA quality obtained from two distinct S. epidermidis bacterial biofilms. Results RNA extracted using the different kits was evaluated for quantity, purity, integrity, and functionally. All kits were able to extract intact and functional total RNA from the biofilms generated from each S. epidermidis strain. The results demonstrated that the kit based on mechanical lysis and organic extraction (FastRNA® Pro Blue was the only one that was able to isolate pure and large quantities of RNA. Normalized expression of the icaA virulence gene showed that RNA extracted with PureLink™ had a significant lower concentration of icaA mRNA transcripts than the other kits tested. Conclusions When working with complex samples, such as biofilms, that contain a high content extracellular polysaccharide and proteins, special care should be taken when selecting the appropriate RNA extraction system, in order to obtain accurate, reproducible, and biologically significant results. Among the RNA extraction kits tested, FastRNA® Pro Blue was the best option for both S. epidermidis biofilms used.

  1. Electron beam extraction from a HVPES

    Energy Technology Data Exchange (ETDEWEB)

    Marghitu, S; Cramariuc, R [Accelerators Laboratory, Institute of Physics and Technology for Radiation Devices, PO Box MG-06, R-76900 Bucharest (Romania); Nicolescu, I; Niculescu, M [Institute of Research and Design for Electrical Engineering, ICPE - Electrostatica, Splaiul Unirii 313, Sect. 3, R-74204 Bucharest (Romania)

    1997-12-31

    The results of the research concerning the extraction system of the fast electrons from a cold cathode high voltage glow discharge plasma electron source (HVPES) are presented. For using the electron beam in a more flexible way, that is changing the shape of the minimum cross-section, (or beam cross-over), of the beam in a sample S frontal plane, without perturbing the discharge parameters, some modifications to a reference internal geometry were tested. Finally, a geometry was found in which the discharge volume may be separated in two parts, one, `a discharge space`, filled with plasma and fast electrons and another, `working space`, occupied specially by the fast electron beam. In this new geometry the electrical discharge parameters, I{sub d} - discharge current, U{sub d} - discharge voltage, were the same as for the reference geometry. (authors) 5 refs., 4 figs., 3 tabs.

  2. A Simple and Fast Extraction Method for the Determination of Multiclass Antibiotics in Eggs Using LC-MS/MS.

    Science.gov (United States)

    Wang, Kun; Lin, Kunde; Huang, Xinwen; Chen, Meng

    2017-06-21

    The purpose of this study was to develop and validate a simple, fast, and specific extraction method for the analysis of 64 antibiotics from nine classes (including sulfonamides, quinolones, tetracyclines, macrolides, lincosamide, nitrofurans, β-lactams, nitromidazoles, and cloramphenicols) in chicken eggs. Briefly, egg samples were simply extracted with a mixture of acetonitrile-water (90:10, v/v) and 0.1 mol·L -1 Na 2 EDTA solution assisted with ultrasonic. The extract was centrifuged, condensed, and directly analyzed on a liquid chromatography coupled to tandem mass spectrometry. Compared with conventional cleanup methods (passing through solid phase extract cartridges), the established method demonstrated comparable efficiencies in eliminating matrix effects and higher or equivalent recoveries for most of the target compounds. Typical validation parameters including specificity, linearity, matrix effect, limits of detection (LODs) and quantification (LOQs), the decision limit, detection capability, trueness, and precision were evaluated. The recoveries of target compounds ranged from 70.8% to 116.1% at three spiking levels (5, 20, and 50 μg·kg -1 ), with relative standard deviations less than 14%. LODs and LOQs were in the ranges of 0.005-2.00 μg·kg -1 and 0.015-6.00 μg·kg -1 for all of the antibiotics, respectively. A total of five antibiotics were successfully detected in 22 commercial eggs from local markets. This work suggests that the method is suitable for the analysis of multiclass antibiotics in eggs.

  3. Pulsed electron beam generation with fast repetitive double pulse system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  4. FAST PALMPRINT AUTHENTICATION BY SOBEL CODE METHOD

    Directory of Open Access Journals (Sweden)

    Jyoti Malik

    2011-05-01

    Full Text Available The ideal real time personal authentication system should be fast and accurate to automatically identify a person’s identity. In this paper, we have proposed a palmprint based biometric authentication method with improvement in time and accuracy, so as to make it a real time palmprint authentication system. Several edge detection methods, wavelet transform, phase congruency etc. are available to extract line feature from the palmprint. In this paper, Multi-scale Sobel Code operators of different orientations (0?, 45?, 90?, and 135? are applied to the palmprint to extract Sobel-Palmprint features in different direc- tions. The Sobel-Palmprint features extracted are stored in Sobel- Palmprint feature vector and matched using sliding window with Hamming Distance similarity measurement method. The sliding win- dow method is accurate but time taking process. In this paper, we have improved the sliding window method so that the matching time reduces. It is observed that there is 39.36% improvement in matching time. In addition, a Min Max Threshold Range (MMTR method is proposed that helps in increasing overall system accuracy by reducing the False Acceptance Rate (FAR. Experimental results indicate that the MMTR method improves the False Acceptance Rate drastically and improvement in sliding window method reduces the comparison time. The accuracy improvement and matching time improvement leads to proposed real time authentication system.

  5. A fast readout system for scintillation detectors

    International Nuclear Information System (INIS)

    Steijger, J.; Kok, E.; Kwakkel, E.; Visschers, J.L.; Zwart, A.N.M.

    1991-01-01

    A system of fast readout electronics for segmented scintillation detectors has been constructed and is now operational. Instead of delaying the analog signals in long coaxial cables, they are digitized immediately and stored in dual-port memories, while the trigger decision is being made. A VMEbus system collects the data from these memories on the data acquisition modules within one crate. Several VME crates are connected via a transputer network to transport the data to an event builder. A separate transputer network is used to perform the VME cycles, needed for the computer-controlled tuning of the experiment. (orig.)

  6. Evaluation of a fast PLC module in prospect of the LHC beam interlock system

    CERN Document Server

    Zaera-Sanz, Manuel

    2005-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC.

  7. A fast image encryption system based on chaotic maps with finite precision representation

    International Nuclear Information System (INIS)

    Kwok, H.S.; Tang, Wallace K.S.

    2007-01-01

    In this paper, a fast chaos-based image encryption system with stream cipher structure is proposed. In order to achieve a fast throughput and facilitate hardware realization, 32-bit precision representation with fixed point arithmetic is assumed. The major core of the encryption system is a pseudo-random keystream generator based on a cascade of chaotic maps, serving the purpose of sequence generation and random mixing. Unlike the other existing chaos-based pseudo-random number generators, the proposed keystream generator not only achieves a very fast throughput, but also passes the statistical tests of up-to-date test suite even under quantization. The overall design of the image encryption system is to be explained while detail cryptanalysis is given and compared with some existing schemes

  8. Systems design of direct-cycle supercritical-water-cooled fast reactors

    International Nuclear Information System (INIS)

    Oka, Yoshiaki; Koshizuka, Seiichi; Jevremovic, Tatjana; Okano, Yashushi

    1995-01-01

    The system design of a direct-cycle supercritical-water-cooled fast reactor is presented. The supercritical water does not exhibit a change of phase. the recirculation system, steam separator, and dryer of a boiling water reactor (BWR) are unnecessary. Roughly speaking, the reactor pressure vessel and control rods are similar to those of a pressurized water reactor, the containment and emergency core cooling system are similar to a BWR, and the balance of plant is similar to a supercritical-pressure fossil-fired power plant (FPP). the electric power of the fast converter is 1,508 MW(electric). The number of coolant loops is only two because of the high coolant enthalpy. Containment volume is much reduced. The thermal efficiency is improved 24% over a BWR. The coolant void reactivity is negative by placing thin zirconium-hydride layers between seeds and blankets. The power costs would be much reduced compared with those of a light water reactor (LWR) and a liquid-metal fast breeder reactor. The concept is based on the huge amount of experience with the water coolant technology of LWRs and FPPs. The oxidation of stainless steel cladding is avoided by adopting a much lower coolant temperature than that of the FPP

  9. A comparison of the Health Star Rating system when used for restaurant fast foods and packaged foods.

    Science.gov (United States)

    Dunford, Elizabeth K; Wu, Jason H Y; Wellard-Cole, Lyndal; Watson, Wendy; Crino, Michelle; Petersen, Kristina; Neal, Bruce

    2017-10-01

    In June 2014, the Australian government agreed to the voluntary implementation of an interpretive 'Health Star Rating' (HSR) front-of-pack labelling system for packaged foods. The aim of the system is to make it easier for consumers to compare the healthiness of products based on number of stars. With many Australians consuming fast food there is a strong rationale for extending the HSR system to include fast food items. To examine the performance of the HSR system when applied to fast foods. Nutrient content data for fast food menu items were collected from the websites of 13 large Australian fast-food chains. The HSR was calculated for each menu item. Statistics describing HSR values for fast foods were calculated and compared to results for comparable packaged foods. Data for 1529 fast food products were compared to data for 3810 packaged food products across 16 of 17 fast food product categories. The mean HSR for the fast foods was 2.5 and ranged from 0.5 to 5.0 and corresponding values for the comparator packaged foods were 2.6 and 0.5 to 5.0. Visual inspection of the data showed broadly comparable distributions of HSR values across the fast food and the packaged food categories, although statistically significant differences were apparent for seven categories (all p fast foods and packaged food, and in others it appeared to reflect primarily differences in the mix of product types within a category. These data support the idea that the HSR system could be extended to Australian fast foods. There are likely to be significant benefits to the community from the use of a single standardised signposting system for healthiness across all fresh, packaged and restaurant foods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Separation of lanthanides using micro solvent extraction system

    International Nuclear Information System (INIS)

    Nishihama, S.; Tajiri, Y.; Yoshizuka, K.

    2006-01-01

    A micro solvent extraction system for the separation of lanthanides has been investigated. The micro flow channel is fabricated on a poly(methyl methacrylate) (PMMA) plate, and solvent extraction progresses by feeding aqueous and organic solutions into the channel simultaneously. The extraction equilibrium is quickly achieved, without any mechanical mixing, when a narrow channel (100 μm width and 100 μm depth) is used. The results of solvent extraction from the Pr/Nd and Pr/Sm binary solutions revealed that both lanthanides are firstly extracted together, and then, the lighter lanthanide extracted in the organic solution alternatively exchanges to the heavier one in the aqueous solution to achieve the extraction equilibrium. The phase separation of the aqueous and organic phases after extraction can also be successively achieved by contriving the cross section of the flow channel, and the extractive separation of Pr/Sm is demonstrated. (authors)

  11. Fast reactor system factors affecting reprocessing plant design

    International Nuclear Information System (INIS)

    Allardice, R.H.; Pugh, O.

    1982-01-01

    The introduction of a commercial fast reactor electricity generating system is very dependent on the availability of an efficient nuclear fuel cycle. Selection of fuel element constructional materials, the fuel element design approach and the reactor operation have a significant influence on the technical feasibility and efficiency of the reprocessing and waste management plants. Therefore the fast reactor processing plant requires liaison between many design teams -reactor, fuel design, reprocessing and waste management -often with different disciplines and conflicting objectives if taken in isolation and an optimised approach to determining several key parameters. A number of these parameters are identified and the design approach discussed in the context of the reprocessing plant. Radiological safety and its impact on design is also briefly discussed. (author)

  12. A Fast Channel Switching Method in EPON System for IPTV Service

    Science.gov (United States)

    Nie, Yaling; Yoshiuchi, Hideya

    This paper presents a fast channel switching method in Ethernet Passive Optical Network (EPON) system for IPTV service. Fast channel switching is one of the important features of successful IPTV systems. Users surely prefer IPTV systems with small channel switching time rather than a longer one. Thus a channel switching control module and a channel/permission list in EPON system’s ONU or OLT is designed. When EPON system receives channel switching message from IPTV end user, the channel switching control module will catch the message and search the channel list and permission list maintained in EPON system, then got the matching parameter of EPON for the new channel. The new channel’s data transmission will be enabled by directly updating the optical filter of the ONU that end user connected. By using this method in EPON system, it provides a solution for dealing with channel switching delays in IPTV service.

  13. Energy Extraction in the CERN Large Hadron Collider a Project Overview

    CERN Document Server

    Dahlerup-Petersen, K; Kazmine, B; Medvedko, A S; Sytchev, V V; Vasilev, L B

    2001-01-01

    In case of a resistive transition (quench), fast and reliable extraction of the magnetic energy, stored in the superconducting coils of the electromagnets of a particle collider, represents an important part of its magnet protection system. In general, the quench detectors, the quench heaters and the cold by-pass diodes across each magnet, together with the energy extraction facilities provide the required protection of the quenching superconductors against damage due to local energy dissipation. In CERN's LHC machine the energy stored in each of its eight superconducting dipole chains exceeds 1300 MJ. Following an opening of the extraction switches this energy will be absorbed in large extraction resistors located in the underground collider tunnel or adjacent galleries, during the exponential current decay. Also the sixteen, 13 kA quadrupole chains (QF, QD) and more than one hundred and fifty, 600 A circuits of the corrector magnets will be equipped with extraction systems. The extraction switch-gear is bas...

  14. 46 CFR 161.002-15 - Sample extraction smoke detection systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Sample extraction smoke detection systems. 161.002-15..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-15 Sample extraction smoke detection systems. The smoke detecting system must consist of a means for...

  15. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid–liquid microextraction coupled with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Anthemidis, Aristidis N.; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D.

    2012-01-01

    Highlights: ► A dispersive liquid–liquid micro extraction method for lead and copper determination. ► A micro-volume transportation system for extractant solvent lighter than water. ► Analysis of natural water samples. - Abstract: A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L −1 and 3.3% for lead and 0.12 μg L −1 and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples.

  16. Note on difference spectra for fast extraction of global image information.

    CSIR Research Space (South Africa)

    Van Wyk, BJ

    2007-06-01

    Full Text Available FOR FAST EXTRACTION OF GLOBAL IMAGE INFORMATION. B.J van Wyk* M.A. van Wyk* and F. van den Bergh** * c29c55c48c51c46c4bc03 c36c52c58c57c4bc03 c24c49c55c4cc46c44c51c03 c37c48c46c4bc51c4cc46c44c4fc03 c2cc51c56c57c4cc57c58c57c48c03 c4cc51c03 c28c4fc48c...46c57c55c52c51c4cc46c56c03 c0bc29cb6c36c24c37c2cc28c0cc03 c44c57c03 c57c4bc48c03 c37c56c4bc5ac44c51c48c03 c38c51c4cc59c48c55c56c4cc57c5cc03 c52c49c03 Technology, Private Bag X680, Pretoria 0001. ** Remote Sensing Research Group, Meraka Institute...

  17. A Novel Eddy Current Septum Magnet for SPS Extraction towards LHC and CNGS

    CERN Document Server

    Schröder, G H; Carlier, E; Dieperink, J H; Ducimetière, L; Goddard, B; Lázár, C; Mayer, M; Vossenberg, Eugène B; Weterings, W

    2000-01-01

    A new East Fast-Extraction System is under construction in the SPS, to supply particles with a maximum batch length of 7.8 us and 10.5 us to the LHC and to CNGS (CERN Neutrino to Gran Sasso), respectively. The extraction septum magnets actually used at the SPS have been designed for slow extraction over several seconds, have large cooling and electrical power demands and need frequently maintenance in a high radiation environment. A fast system of only 250 us pulse duration has therefore been developed, using a half-sine excitation pulse with a superimposed third harmonic. The short pulse duration requires very thin magnetic yoke laminations, which can not easily be stamped and stacked. Profiting from a development for the LHC beam dump kicker magnets, the yoke is therefore built-up from tape-wound cylindrical cores, employing 50 um thick Si-steel tape. Thirty two cores are stacked longitudinally to produce a yoke of 3.2 meter length. The aperture is cut radial into each cylinder. The cores are radial compres...

  18. Fast flux test facility noise data management

    International Nuclear Information System (INIS)

    Thie, J.A.

    1988-01-01

    An extensive collection of spectra from an automated data collection system at the Fast Flux Facility has features from neutron data extracted and managed by database software. Inquiry techniques, including screening, applied to database results show the influences of control rods on wideband noise and, more generally, abilities to detect diverse types of off-normal noise. Uncovering a temporary 0.1-Hz resonance shift gave additional diagnostic information on a 13-Hz mechanical motion characterized by the interference of two resonances. The latter phenomenon is discussed generically for possible application to other reactor types. (author)

  19. Digital extraction of interference fringe contours

    International Nuclear Information System (INIS)

    Mastin, G.A.; Ghiglia, D.C.

    1985-01-01

    Two basic techniques for extracting interferogram contours have been discussed. The first is a global contour extracton technique based on the fast Fourier transform. The second extracts individual contours with a thinning algorithm using logical neighborhood transformations

  20. Fluctuation-Response Relation and modeling in systems with fast and slow dynamics

    Directory of Open Access Journals (Sweden)

    G. Lacorata

    2007-10-01

    Full Text Available We show how a general formulation of the Fluctuation-Response Relation is able to describe in detail the connection between response properties to external perturbations and spontaneous fluctuations in systems with fast and slow variables. The method is tested by using the 360-variable Lorenz-96 model, where slow and fast variables are coupled to one another with reciprocal feedback, and a simplified low dimensional system. In the Fluctuation-Response context, the influence of the fast dynamics on the slow dynamics relies in a non trivial behavior of a suitable quadratic response function. This has important consequences for the modeling of the slow dynamics in terms of a Langevin equation: beyond a certain intrinsic time interval even the optimal model can give just statistical prediction.

  1. Pilot studies of an extraction process for reprocessing of spent fuel from fast reactors: Hardware and process details of extractor selection

    International Nuclear Information System (INIS)

    Anisimov, V.I.; Pavlovich, V.B.; Smetanin, E.Ya.; Glazunov, N.V.; Shklyar, L.I.; Dubrovskii, V.G.; Serov, A.V.; Zakharkin, B.S.; Konorchenko, V.D.; Korotkov, I.A.; Neumoev, N.V.; Renard, E.V.

    1992-01-01

    While acknowledging the bold and persistent efforts of U.S. and Russian specialists to develop the concept of pyrochemical reprocessing of spent nuclear fuel from fast reactors on remote-controlled equipment for removal of actinides from the fission products one should recognize that the tasks of reprocessing such fuel can be handled only by using water-extraction technology, especially since the known Purex process continues to be improved to the point that a single-cycle scheme may be developed. This article presents results of pilot studies conducted in hot cells using multistage extractors in continuous counterflow operation; data on various extractor types used in reprocessing spent mixed oxide nuclear fuel; advantages and disadvantages of centrifugal and pulsed column extractor; comparison of column-type and centrifugal extractors; and extraction process

  2. European nuclear data studies for fast systems

    International Nuclear Information System (INIS)

    Rullhusen, P.; Hambsch, F.-J.; Mondelaers, W.; Plompen, A.J.M.; Schillebeeckx, P.

    2010-01-01

    Nuclear data needs for fast systems are highlighted and the following projects are described: Joint European research projects: MUSE Experiments for Sub-critical Neutronics Validation; High- and Intermediate Energy Nuclear Data for ADS (HINDAS); and the Time-Of-Flight facility for Nuclear Data Measurements for ADS (n T OF N D A DS); European Research Programme for the Transmutation of High Level Nuclear Waste in an Accelerator Driven System (EUROTRANS-NUDATRA); and CANDIDE; Programmes for transnational access to experimental facilities in Europe: European Facilities for Nuclear Data Measurements (EFNUDAT); Neutron Data Measurements at IRMM (NUDAME); European facility for innovative reactor and transmutation neutron data (EUFRAT) (P.A.)

  3. Fast breeder reactor reference system classification for the ENEA data bank

    International Nuclear Information System (INIS)

    Righini, R.

    1988-01-01

    This report contains the Reference System Classification (RSC) of fast breeder reactors: it provides a functional system breakdown of the reactor. For each system the following important characteristics are reported: the main function, the mode of operation, its location in the reactor, the main interface system, its main components and the component working environment (fluid and/or atmosphere type). The RSC represent a basic step in organizing the ENEA data bank for the registration and processing of reliability data on typical fast reactor components; it provides a functional component breakdown and represent a plant-unique identification in the process of omogenization of event-data coming from different reactors. In this report it was tried to take into account different generations of nuclear power plants, different plant layouts and solutions: in particular loop and pool reactors are separately treated

  4. Extracting rate coefficients from single-molecule photon trajectories and FRET efficiency histograms for a fast-folding protein.

    Science.gov (United States)

    Chung, Hoi Sung; Gopich, Irina V; McHale, Kevin; Cellmer, Troy; Louis, John M; Eaton, William A

    2011-04-28

    Recently developed statistical methods by Gopich and Szabo were used to extract folding and unfolding rate coefficients from single-molecule Förster resonance energy transfer (FRET) data for proteins with kinetics too fast to measure waiting time distributions. Two types of experiments and two different analyses were performed. In one experiment bursts of photons were collected from donor and acceptor fluorophores attached to a 73-residue protein, α(3)D, freely diffusing through the illuminated volume of a confocal microscope system. In the second, the protein was immobilized by linkage to a surface, and photons were collected until one of the fluorophores bleached. Folding and unfolding rate coefficients and mean FRET efficiencies for the folded and unfolded subpopulations were obtained from a photon by photon analysis of the trajectories using a maximum likelihood method. The ability of the method to describe the data in terms of a two-state model was checked by recoloring the photon trajectories with the extracted parameters and comparing the calculated FRET efficiency histograms with the measured histograms. The sum of the rate coefficients for the two-state model agreed to within 30% with the relaxation rate obtained from the decay of the donor-acceptor cross-correlation function, confirming the high accuracy of the method. Interestingly, apparently reliable rate coefficients could be extracted using the maximum likelihood method, even at low (rate coefficients and mean FRET efficiencies were also obtained in an approximate procedure by simply fitting the FRET efficiency histograms, calculated by binning the donor and acceptor photons, with a sum of three-Gaussian functions. The kinetics are exposed in these histograms by the growth of a FRET efficiency peak at values intermediate between the folded and unfolded peaks as the bin size increases, a phenomenon with similarities to NMR exchange broadening. When comparable populations of folded and unfolded

  5. A simple and fast determination of microgram thorium in organic solution containing several hundreds times amount of uranium

    International Nuclear Information System (INIS)

    Yin Duanzhi; Cao Benhong; Yang Jinfeng

    1991-01-01

    Using spectrophotometric method, microgram thorium in 30% TBP-kerosene system containing large amount of uranium was successfully determined after one-step back-extraction with hydrochloric acid. The recovery of thorium is more than 98%, and the separation factor α U/Th is over 1 x 10 3 . Being reliable, simple and fast, the recommended method has been used in the research on spent fuel reprocessing and is expected applicable to other neutral phosphate extraction systems such as TOPO and DMHMP

  6. A data-driven prediction method for fast-slow systems

    Science.gov (United States)

    Groth, Andreas; Chekroun, Mickael; Kondrashov, Dmitri; Ghil, Michael

    2016-04-01

    In this work, we present a prediction method for processes that exhibit a mixture of variability on low and fast scales. The method relies on combining empirical model reduction (EMR) with singular spectrum analysis (SSA). EMR is a data-driven methodology for constructing stochastic low-dimensional models that account for nonlinearity and serial correlation in the estimated noise, while SSA provides a decomposition of the complex dynamics into low-order components that capture spatio-temporal behavior on different time scales. Our study focuses on the data-driven modeling of partial observations from dynamical systems that exhibit power spectra with broad peaks. The main result in this talk is that the combination of SSA pre-filtering with EMR modeling improves, under certain circumstances, the modeling and prediction skill of such a system, as compared to a standard EMR prediction based on raw data. Specifically, it is the separation into "fast" and "slow" temporal scales by the SSA pre-filtering that achieves the improvement. We show, in particular that the resulting EMR-SSA emulators help predict intermittent behavior such as rapid transitions between specific regions of the system's phase space. This capability of the EMR-SSA prediction will be demonstrated on two low-dimensional models: the Rössler system and a Lotka-Volterra model for interspecies competition. In either case, the chaotic dynamics is produced through a Shilnikov-type mechanism and we argue that the latter seems to be an important ingredient for the good prediction skills of EMR-SSA emulators. Shilnikov-type behavior has been shown to arise in various complex geophysical fluid models, such as baroclinic quasi-geostrophic flows in the mid-latitude atmosphere and wind-driven double-gyre ocean circulation models. This pervasiveness of the Shilnikow mechanism of fast-slow transition opens interesting perspectives for the extension of the proposed EMR-SSA approach to more realistic situations.

  7. [DNA Extraction from Old Bones by AutoMate Express™ System].

    Science.gov (United States)

    Li, B; Lü, Z

    2017-08-01

    To establish a method for extracting DNA from old bones by AutoMate Express™ system. Bones were grinded into powder by freeze-mill. After extraction by AutoMate Express™, DNA were amplified and genotyped by Identifiler®Plus and MinFiler™ kits. DNA were extracted from 10 old bone samples, which kept in different environments with the postmortem interval from 10 to 20 years, in 3 hours by AutoMate Express™ system. Complete STR typing results were obtained from 8 samples. AutoMate Express™ system can quickly and efficiently extract DNA from old bones, which can be applied in forensic practice. Copyright© by the Editorial Department of Journal of Forensic Medicine

  8. A fast multichannel analog storage system

    International Nuclear Information System (INIS)

    Freytag, D.R.

    1983-01-01

    A Multichannel Analog Storage System based on a commercial 32-channel parallel in/serial out (PISO) analog shift register is described. The basic unit is a single width CAMAC module containing 512 analog cells and the associated logic for data storage and subsequent readout. At sampling rates of up to 30 MHz the signals are strobed directly into the PISO. At higher rates signals are strobed into a fast presampling stage and subsequently transferred in block form into an array of PISO's. Sampling rates of 300 MHz have been achieved with the present device and 1000 MHz are possible with improved signal drivers. The system is well suited for simultaneous handling of many signal channels with moderate numbers of samples in each channel. RMS noise over full scale signal has been measured as 1:3000 (approx. =11 bit). However, nonlinearities in the response and differences in sensitivity of the analog cells require an elaborate calibration system in order to realize 11 bit accuracy for the analog information

  9. Fast GPU-based spot extraction for energy-dispersive X-ray Laue diffraction

    International Nuclear Information System (INIS)

    Alghabi, F.; Schipper, U.; Kolb, A.; Send, S.; Abboud, A.; Pashniak, N.; Pietsch, U.

    2014-01-01

    This paper describes a novel method for fast online analysis of X-ray Laue spots taken by means of an energy-dispersive X-ray 2D detector. Current pnCCD detectors typically operate at some 100 Hz (up to a maximum of 400 Hz) and have a resolution of 384 × 384 pixels, future devices head for even higher pixel counts and frame rates. The proposed online data analysis is based on a computer utilizing multiple Graphics Processing Units (GPUs), which allow for fast and parallel data processing. Our multi-GPU based algorithm is compliant with the rules of stream-based data processing, for which GPUs are optimized. The paper's main contribution is therefore an alternative algorithm for the determination of spot positions and energies over the full sequence of pnCCD data frames. Furthermore, an improved background suppression algorithm is presented.The resulting system is able to process data at the maximum acquisition rate of 400 Hz. We present a detailed analysis of the spot positions and energies deduced from a prior (single-core) CPU-based and the novel GPU-based data processing, showing that the parallel computed results using the GPU implementation are at least of the same quality as prior CPU-based results. Furthermore, the GPU-based algorithm is able to speed up the data processing by a factor of 7 (in comparison to single-core CPU-based algorithm) which effectively makes the detector system more suitable for online data processing

  10. Preparation of magnetic core mesoporous shell microspheres with C18-modified interior pore-walls for fast extraction and analysis of phthalates in water samples.

    Science.gov (United States)

    Li, Zhongbo; Huang, Danni; Fu, Chinfai; Wei, Biwen; Yu, Wenjia; Deng, Chunhui; Zhang, Xiangmin

    2011-09-16

    In this study, core-shell magnetic mesoporous microspheres with C18-functionalized interior pore-walls were synthesized through coating Fe(3)O(4) microspheres with a mesoporous inorganic-organic hybrid layer with a n-octadecyltriethoxysilane (C18TES) and tetraethyl orthosilicate (TEOS) as the silica source and cetyltrimethylammonia bromide (CTAB) as a template. The obtained C18-functionalized Fe(3)O(4)@mSiO(2) microspheres possess numerous C18 groups anchored in the interior pore-walls, large surface area (274.7 m(2)/g, high magnetization (40.8 emu/g) and superparamagnetism, uniform mesopores (4.1 nm), which makes them ideal absorbents for simple, fast, and efficient extraction and enrichment of hydrophobic organic compounds in water samples. Several kinds of phthalates were used as the model hydrophobic organic compounds to systematically evaluate the performance of the C18-functionalized Fe(3)O(4)@mSiO(2) microspheres in extracting hydrophobic molecules by using a gas chromatography-mass spectrometry. Various parameters, including eluting solvent, the amounts of absorbents, extraction time and elution time were optimized. Hydrophobic extraction was performed in the interior pore of magnetic mesoporous microspheres, and the materials had the anti-interference ability to macromolecular proteins, which was also investigated in the work. Under the optimized conditions, C18-functionalized Fe(3)O(4)@mSiO(2) microspheres were successfully used to analyze the real water samples. The results indicated that this novel method was fast, convenient and efficient for the target compounds and could avoid being interfered by macromolecules. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Electron beam extraction system with a ring radiation field

    International Nuclear Information System (INIS)

    Auslender, V.L.; Kuksanov, N.K.; Polyakov, V.A.; Salimov, R.A.; Chertok, I.L.

    1979-01-01

    Description and results of testings of two electron beam extraction systems for shaping of a circular irradiation field are given. One of the systems contains three 20 cm long outlet windows arranged at 120 deg angle with respect to each other. Tests at the ILU-6 accelerator have shown that the given system provides 150 mm zone irradiation from three sides. Beam utilization factor when irradiating three 40 mm dia tubes amounted to 35% which provides capacity of 2.5 txMrad/h at 20 kW beam power. The other extraction system includes two C-form magnets producing nonuniform and opposing magnetic fields. This system tests at the EhLV-2 accelerator have shown that at 0.8-1.5 MeV electron energy it is possible to irradiate of 60 and 100 mm dia objects, accordingly. The system may be used together with both constant-action and pulse-action accelerators having extraction with linear scanning [ru

  12. Repeated extraction of DNA from FTA cards

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Ferrero, Laura; Børsting, Claus

    2011-01-01

    Extraction of DNA using magnetic bead based techniques on automated DNA extraction instruments provides a fast, reliable and reproducible method for DNA extraction from various matrices. However, the yield of extracted DNA from FTA-cards is typically low. Here, we demonstrate that it is possible...... to repeatedly extract DNA from the processed FTA-disk. The method increases the yield from the nanogram range to the microgram range....

  13. FEATURE RECOGNITION BERBASIS CORNER DETECTION DENGAN METODE FAST, SURF DAN FLANN TREE UNTUK IDENTIFIKASI LOGO PADA AUGMENTED REALITY MOBILE SYSTEM

    Directory of Open Access Journals (Sweden)

    Rastri Prathivi

    2014-01-01

    Full Text Available Logo is a graphical symbol that is the identity of an organization, institution, or company. Logo is generally used to introduce to the public the existence of an organization, institution, or company. Through the existence of an agency logo can be seen by the public. Feature recognition is one of the processes that exist within an augmented reality system. One of uses augmented reality is able to recognize the identity of the logo through a camera.The first step to make a process of feature recognition is through the corner detection. Incorporation of several method such as FAST, SURF, and FLANN TREE for the feature detection process based corner detection feature matching up process, will have the better ability to detect the presence of a logo. Additionally when running the feature extraction process there are several issues that arise as scale invariant feature and rotation invariant feature. In this study the research object in the form of logo to the priority to make the process of feature recognition. FAST, SURF, and FLANN TREE method will detection logo with scale invariant feature and rotation invariant feature conditions. Obtained from this study will demonstration the accuracy from FAST, SURF, and FLANN TREE methods to solve the scale invariant and rotation invariant feature problems.

  14. Extractive text summarization system to aid data extraction from full text in systematic review development.

    Science.gov (United States)

    Bui, Duy Duc An; Del Fiol, Guilherme; Hurdle, John F; Jonnalagadda, Siddhartha

    2016-12-01

    Extracting data from publication reports is a standard process in systematic review (SR) development. However, the data extraction process still relies too much on manual effort which is slow, costly, and subject to human error. In this study, we developed a text summarization system aimed at enhancing productivity and reducing errors in the traditional data extraction process. We developed a computer system that used machine learning and natural language processing approaches to automatically generate summaries of full-text scientific publications. The summaries at the sentence and fragment levels were evaluated in finding common clinical SR data elements such as sample size, group size, and PICO values. We compared the computer-generated summaries with human written summaries (title and abstract) in terms of the presence of necessary information for the data extraction as presented in the Cochrane review's study characteristics tables. At the sentence level, the computer-generated summaries covered more information than humans do for systematic reviews (recall 91.2% vs. 83.8%, p<0.001). They also had a better density of relevant sentences (precision 59% vs. 39%, p<0.001). At the fragment level, the ensemble approach combining rule-based, concept mapping, and dictionary-based methods performed better than individual methods alone, achieving an 84.7% F-measure. Computer-generated summaries are potential alternative information sources for data extraction in systematic review development. Machine learning and natural language processing are promising approaches to the development of such an extractive summarization system. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Interaction between Sex Hormones and Matricaria Chamomilla Hydroalcholic Extract on Motor Activity Behavior in Gonadectomized Male and Female Mice

    Directory of Open Access Journals (Sweden)

    H. Raie

    2006-04-01

    Full Text Available Introduction & Objective: Locomotor activity is an important physiologic phenomenon that is influenced by several factors. In previous study we showed that the matricaria chamomilla (chamomile hydroalcholic extract acts differently in male and female mice. Therefore in this study, the role of sex hormones and chamomile hydroalcholic extract were investigated on motor activity behavior in absence of sex glands in adult male and female NMRI mice. Materials and Methods: Gonadectomized male and female mice were divided into groups (seven mice in each group including: receiving testosterone (2 mg/kg S.C., estradiol benzoate (0.1 mg/kg S.C., and progesterone (0.5 mg/kg S.C. with and without hydroalcholic extract of chamomile (50 mg/kg i.p. Motor activity monitor system was used to evaluate locomotor activity parameters (fast and slow activity, fast and slow stereotype activity, fast and slow rearing in all groups. Results: 1 Testosterone had no any effect on motor activity parameters, but extract of chamomile with and without testosterone decreased motor activity parameters in male mice. 2 Estradiol benzoate and chamomile hydroalcholic extract in presence and absence of each other increased locomotor activity parameters in female mice. 3 Progesterone also did not change motor activity parameters in presence and absence of chamomile hydroalcholic extract in female mice. 4 Administration of Estradiol benzoate with progestrone in presence and absence of chamomile hydroalcholic extract did not alter motor activity parameters in female mice. Conclusion: It seems both of the chamomile hydroalcholic extract and estradiol enhance motor activity and probably act through same system and potentiate the effect of each other. Also it seems there are interaction between estradiol and progesterone and also between chamomile extract and progesterone. Testosterone probably did not have any interaction with chamomile extract in locomotor activity.

  16. Advanced integrated solvent extraction and ion exchange systems

    International Nuclear Information System (INIS)

    Horwitz, P.

    1996-01-01

    Advanced integrated solvent extraction (SX) and ion exchange (IX) systems are a series of novel SX and IX processes that extract and recover uranium and transuranics (TRUs) (neptunium, plutonium, americium) and fission products 90 Sr, 99 Tc, and 137 Cs from acidic high-level liquid waste and that sorb and recover 90 Sr, 99 Tc, and 137 Cs from alkaline supernatant high-level waste. Each system is based on the use of new selective liquid extractants or chromatographic materials. The purpose of the integrated SX and IX processes is to minimize the quantity of waste that must be vitrified and buried in a deep geologic repository by producing raffinates (from SX) and effluent streams (from IX) that will meet the specifications of Class A low-level waste

  17. Evaluation and application of a fast module in a PLC based interlock and control system

    International Nuclear Information System (INIS)

    Zaera-Sanz, M

    2009-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a 'so called' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.

  18. Heterocyclic aromatic amine content in chicken burgers and chicken nuggets sold in fast food restaurants and effects of green tea extract and microwave thawing on their formation

    Science.gov (United States)

    The aims of the current study were to investigate the presence of carcinogenic and mutagenic heterocyclic aromatic amines (HAAs) in chicken burgers (CBs) and chicken nuggets (CNs) purchased from fast food restaurants and the effects of green tea extract addition (GTE) to the covering material as wel...

  19. A system for fast neutron radiography

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this sytem, objects as small as a coin or as large as a waste drum can be radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3x10 10 neutrons/second with an average energy of 14.5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available cassettes. The cassettes have been modified to include a thin sheet of plastic to convert neutrons to protons through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9x10 7 to 3.8x10 8 n/cm 2 depending on the type of screen and film

  20. Arduino-based automation of a DNA extraction system.

    Science.gov (United States)

    Kim, Kyung-Won; Lee, Mi-So; Ryu, Mun-Ho; Kim, Jong-Won

    2015-01-01

    There have been many studies to detect infectious diseases with the molecular genetic method. This study presents an automation process for a DNA extraction system based on microfluidics and magnetic bead, which is part of a portable molecular genetic test system. This DNA extraction system consists of a cartridge with chambers, syringes, four linear stepper actuators, and a rotary stepper actuator. The actuators provide a sequence of steps in the DNA extraction process, such as transporting, mixing, and washing for the gene specimen, magnetic bead, and reagent solutions. The proposed automation system consists of a PC-based host application and an Arduino-based controller. The host application compiles a G code sequence file and interfaces with the controller to execute the compiled sequence. The controller executes stepper motor axis motion, time delay, and input-output manipulation. It drives the stepper motor with an open library, which provides a smooth linear acceleration profile. The controller also provides a homing sequence to establish the motor's reference position, and hard limit checking to prevent any over-travelling. The proposed system was implemented and its functionality was investigated, especially regarding positioning accuracy and velocity profile.

  1. Fast response system for vacuum volume emergency separation

    International Nuclear Information System (INIS)

    Gubrienko, K.I.; Lastochkin, Yu.A.

    1982-01-01

    A system which allows to separate vacuum systems of the magnetic-optic beam channels connected with the accelerator has been worked out for case of emergency environment break through the extraction ''window''. The system, consisting of two valve - gate devices and a control unit, allows one in the emergency case to separate more than 20 m long volume from the accelerator without any pressure changes in the latter one

  2. Three-dimensional spatiotemporal features for fast content-based retrieval of focal liver lesions.

    Science.gov (United States)

    Roy, Sharmili; Chi, Yanling; Liu, Jimin; Venkatesh, Sudhakar K; Brown, Michael S

    2014-11-01

    Content-based image retrieval systems for 3-D medical datasets still largely rely on 2-D image-based features extracted from a few representative slices of the image stack. Most 2 -D features that are currently used in the literature not only model a 3-D tumor incompletely but are also highly expensive in terms of computation time, especially for high-resolution datasets. Radiologist-specified semantic labels are sometimes used along with image-based 2-D features to improve the retrieval performance. Since radiological labels show large interuser variability, are often unstructured, and require user interaction, their use as lesion characterizing features is highly subjective, tedious, and slow. In this paper, we propose a 3-D image-based spatiotemporal feature extraction framework for fast content-based retrieval of focal liver lesions. All the features are computer generated and are extracted from four-phase abdominal CT images. Retrieval performance and query processing times for the proposed framework is evaluated on a database of 44 hepatic lesions comprising of five pathological types. Bull's eye percentage score above 85% is achieved for three out of the five lesion pathologies and for 98% of query lesions, at least one same type of lesion is ranked among the top two retrieved results. Experiments show that the proposed system's query processing is more than 20 times faster than other already published systems that use 2-D features. With fast computation time and high retrieval accuracy, the proposed system has the potential to be used as an assistant to radiologists for routine hepatic tumor diagnosis.

  3. Corn silk aqueous extracts and intraocular pressure of systemic and non-systemic hypertensive subjects.

    Science.gov (United States)

    George, Gladys O; Idu, Faustina K

    2015-03-01

    Hypotensive properties have been attributed to the stigma/style of Zea mays L (corn silk). Although the effect of corn silk extract on blood pressure has been documented in animal studies, we are not aware of any study on its effect on human blood pressure and intraocular pressure. A randomised study was carried out on the effect of water only, masked doses of corn silk aqueous extract (60, 130, 192.5 and 260 mg/kg body weight) on intraocular pressure and blood pressure of 20 systemic and 20 non-systemic hypertensive subjects. Intraocular pressure and blood pressure were measured at baseline and every hour for eight hours after administering water or a masked dose of corn silk aqueous extract. Each dose was administered at two-week intervals to each subject in the two study groups. The results showed that the last three doses of corn silk aqueous extract gave a statistically significant reduction (p Corn silk aqueous extract has a lowering effect on intraocular pressure in systemic and non-systemic hypertensive subjects. This may have resulted from the fall in blood pressure that is due to potassium-induced natriuresis and diuresis caused by the high potassium content in the high doses of the corn silk extract. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  4. Ultrasound assisted extraction combined with dispersive liquid-liquid microextraction (US-DLLME)-a fast new approach to measure phthalate metabolites in nails.

    Science.gov (United States)

    Alves, Andreia; Vanermen, Guido; Covaci, Adrian; Voorspoels, Stefan

    2016-09-01

    A new, fast, and environmentally friendly method based on ultrasound assisted extraction combined with dispersive liquid-liquid microextraction (US-DLLME) was developed and optimized for assessing the levels of seven phthalate metabolites (including the mono(ethyl hexyl) phthalate (MEHP), mono(2-ethyl-5-hydroxyhexyl) phthalate (5-OH-MEHP), mono(2-ethyl-5-oxohexyl) phthalate (5-oxo-MEHP), mono-n-butyl phthalate (MnBP), mono-isobutyl phthalate (MiBP), monoethyl phthalate (MEP), and mono-benzyl phthalate (MBzP)) in human nails by UPLC-MS/MS. The optimization of the US-DLLME method was performed using a Taguchi combinatorial design (L9 array). Several parameters such as extraction solvent, solvent volume, extraction time, acid, acid concentration, and vortex time were studied. The optimal extraction conditions achieved were 180 μL of trichloroethylene (extraction solvent), 2 mL trifluoroacetic acid in methanol (2 M), 2 h extraction and 3 min vortex time. The optimized method had a good precision (6-17 %). The accuracy ranged from 79 to 108 % and the limit of method quantification (LOQm) was below 14 ng/g for all compounds. The developed US-DLLME method was applied to determine the target metabolites in 10 Belgian individuals. Levels of the analytes measured in nails ranged between <12 and 7982 ng/g. The MEHP, MBP isomers, and MEP were the major metabolites and detected in every sample. Miniaturization (low volumes of organic solvents used), low costs, speed, and simplicity are the main advantages of this US-DLLME based method. Graphical Abstract Extraction and phase separation of the US-DLLME procedure.

  5. Optimization of a flow injection analysis system for multiple solvent extraction

    International Nuclear Information System (INIS)

    Rossi, T.M.; Shelly, D.C.; Warner, I.M.

    1982-01-01

    The performance of a multistage flow injection analysis solvent extraction system has been optimized. The effect of solvent segmentation devices, extraction coils, and phase separators on performance characteristics is discussed. Theoretical consideration is given to the effects and determination of dispersion and the extraction dynamics within both glass and Teflon extraction coils. The optimized system has a sample recovery similar to an identical manual procedure and a 1.5% relative standard deviation between injections. Sample throughput time is under 5 min. These characteristics represent significant improvements over the performance of the same system before optimization. 6 figures, 2 tables

  6. Fast ultrasonic visualisation under sodium. Application to the fast neutron reactors

    International Nuclear Information System (INIS)

    Imbert, Ch.

    1997-01-01

    The fast ultrasonic visualization under sodium is in the programme of research and development on the inspection inside the fast neutron reactors. This work is about the development of a such system of fast ultrasonic imaging under sodium, in order to improve the existing visualization systems. This system is based on the principle of orthogonal imaging, it uses two linear antennas with an important dephasing having 128 piezo-composite elements of central frequency equal to 1.6 MHz. (N.C.)

  7. Fast exhaustive search for polynomial systems in F2

    NARCIS (Netherlands)

    Bouillaguet, C.; Chen, H.-C.; Cheng, C.M.; Chou, T.; Niederhagen, R.F.; Shamir, A.; Yang, B.Y.

    2010-01-01

    Abstract. We analyze how fast we can solve general systems of multivariate equations of various low degrees over F2; this is a well known hard problem which is important both in itself and as part of many types of algebraic cryptanalysis. Compared to the standard exhaustive-search technique, our

  8. Fast exhaustive search for polynomial systems in F2

    NARCIS (Netherlands)

    Bouillaguet, C.; Chen, H.-C.; Cheng, C.M.; Chou, T.; Niederhagen, R.F.; Shamir, A.; Yang, B.Y.; Mangard, S.; Standaert, F.X.

    2010-01-01

    Abstract: We analyze how fast we can solve general systems of multivariate equations of various low degrees over $F_2$; this is a well known hard problem which is important both in itself and as part of many types of algebraic cryptanalysis. Compared to the standard exhaustive search technique, our

  9. Development of blood extraction system for health monitoring system

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2004-03-01

    The purpose of this research is to develop the compact human blood sampling device applied for a health monitoring system(HMS), which is called "Mobile Hospital". The HMS consists of (1) a micro electrical pumping system for blood extraction, (2) a bio-sensor to detect and evaluate an amount of Glucose, Cholesterol and Urea in extracted blood, by using enzyme such as Glucoseoxidase (GOD), Cholesteroloxidase and Urease. The mechanical design elements of the device are bio-compatible microneedle, indentation unit using a shape memory alloy(SMA) actuator and pumping unit using a piezoelectric microactuator. The design concept is the biomimetic micromachine of female mosquito"s blood sampling mechanism. The performances of the main mechanical elements such as indentation force of the microneedle, actual stroke of the indentation unit using a SMA actuator and liquid sampling ability of the pumping unit using PZT piezoelectric microactuator were measured. The 3 mm stroke of the indentation load generated by SMA actuator was 0.8mN. The amount of imitation blood extracted by using bimorph PZT actuators was about 0.5 microliters for 10 sec. A 60-micrometer outer diameter and 25-micrometer inner diameter Titanium microneedle, which size is same as female mosquito"s labium, was produced by sputter deposition.

  10. Portable blood extraction device integrated with biomedical monitoring system

    Science.gov (United States)

    Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S.

    2006-01-01

    Painless and portable blood extraction device has been immersed in the world of miniaturization on bio-medical research particularly in manufacturing point-of-care systems. The fabrication of a blood extraction device integrated with an electrolyte-monitoring system is reported in this paper. The device has advantages in precise controlled dosage of blood extracted including the slightly damaged blood vessels and nervous system. The in-house blood diagnostic will become simple for the patients. Main components of the portable system are; the blood extraction device and electrolyte-monitoring system. The monitoring system consists of ISFET (Ion Selective Field Effect Transistor) for measuring the concentration level of minerals in blood. In this work, we measured the level of 3 ions; Na+, K+ and Cl-. The mentioned ions are frequently required the measurement since their concentration levels in the blood can indicate whether the kidney, pancreas, liver or heart is being malfunction. The fabrication of the whole system and experimentation on each ISM (Ion Sensitive Membrane) will be provided. Taking the advantages of LIGA technology, the 100 hollow microneedles fabricated by Synchrotron Radiation deep X-ray lithography through PCT (Plane-pattern to Cross-section Transfer) technique have been consisted in 5x5 mm2 area. The microneedle is 300 μm in base-diameter, 500 μm-pitch, 800 μm-height and 50 μm hole-diameter. The total size of the blood extraction device is 2x2x2 cm 3. The package is made from a plastic socket including slots for inserting microneedle array and ISFET connecting to an electrical circuit for the monitoring. Through the dimensional design for simply handling and selection of disposable material, the patients can self-evaluate the critical level of the body minerals in anywhere and anytime.

  11. Neutron-physical simulation of fast nuclear reactor cores. Investigation of new and emerging nuclear reactor systems

    International Nuclear Information System (INIS)

    Friess, Friederike Renate

    2017-01-01

    According to a many publications and discussions, fast reactors hold promises to improve safety, non-proliferation, economic aspects, and reduce the nuclear waste problems. Consequently, several reactor designs advocated by the Generation IV Forum are fast reactors. In reality, however, after decades of research and development and billions of dollars investment worldwide, there are only two fast breeders currently operational on a commercial basis: the Russian reactors BN-600 and BN-800. Energy generation alone is apparently not a sufficient selling point for fast breeder reactors. Therefore, other possible applications for fast nuclear reactors are advocated. Three relevant examples are investigated in this thesis. The first one is the disposition of excess weapon-grade plutonium. Unlike for high enriched uranium that can be downblended for use in light water reactors, there exists no scientifically accepted solution for the disposition of weapon-grade plutonium. One option is the use in fast reactors that are operated for energy production. In the course of burn-up, the plutonium is irradiated which intends to fulfill two objectives: the resulting isotopic composition of the plutonium is less suitable for nuclear weapons, while at the same time the build-up of fission products results in a radiation barrier. Appropriate reprocessing technology is in order to extract the plutonium from the spent fuel. The second application is the use as so-called nuclear batteries, a special type of small modular reactors (SMRs). Nuclear batteries offer very long core lifetimes and have a very small energy output of sometimes only 10 MWe. They can supposedly be placed (almost) everywhere and supply energy without the need for refueling or shuffling of fuel elements for long periods. Since their cores remain sealed for several decades, nuclear batteries are claimed to have a higher proliferation resistance. The small output and the reduced maintenance and operating requirements

  12. Neutron-physical simulation of fast nuclear reactor cores. Investigation of new and emerging nuclear reactor systems

    Energy Technology Data Exchange (ETDEWEB)

    Friess, Friederike Renate

    2017-07-12

    According to a many publications and discussions, fast reactors hold promises to improve safety, non-proliferation, economic aspects, and reduce the nuclear waste problems. Consequently, several reactor designs advocated by the Generation IV Forum are fast reactors. In reality, however, after decades of research and development and billions of dollars investment worldwide, there are only two fast breeders currently operational on a commercial basis: the Russian reactors BN-600 and BN-800. Energy generation alone is apparently not a sufficient selling point for fast breeder reactors. Therefore, other possible applications for fast nuclear reactors are advocated. Three relevant examples are investigated in this thesis. The first one is the disposition of excess weapon-grade plutonium. Unlike for high enriched uranium that can be downblended for use in light water reactors, there exists no scientifically accepted solution for the disposition of weapon-grade plutonium. One option is the use in fast reactors that are operated for energy production. In the course of burn-up, the plutonium is irradiated which intends to fulfill two objectives: the resulting isotopic composition of the plutonium is less suitable for nuclear weapons, while at the same time the build-up of fission products results in a radiation barrier. Appropriate reprocessing technology is in order to extract the plutonium from the spent fuel. The second application is the use as so-called nuclear batteries, a special type of small modular reactors (SMRs). Nuclear batteries offer very long core lifetimes and have a very small energy output of sometimes only 10 MWe. They can supposedly be placed (almost) everywhere and supply energy without the need for refueling or shuffling of fuel elements for long periods. Since their cores remain sealed for several decades, nuclear batteries are claimed to have a higher proliferation resistance. The small output and the reduced maintenance and operating requirements

  13. Very Fast Losses of the Circulating LHC Beam, their Mitigation and Machine Protection

    CERN Document Server

    Baer, Tobias; Elsen, Eckhard

    The Large Hadron Collider (LHC) has a nominal energy of 362MJ stored in each of its two counter-rotating beams - over two orders of magnitude more than any previous accelerator and enough to melt 880kg of copper. Therefore, in case of abnormal conditions comprehensive machine protection systems extract the beams safely from the LHC within not more than three turns $\\approx$270$\\mu$s. The first years of LHC operation demonstrated a remarkable reliability of the major machine protection systems. However, they also showed that the LHC is vulnerable to losses of the circulating beams on very fast timescales, which are too fast to ensure an active protection. Very fast equipment failures, in particular of normal-conducting dipole magnets and the transverse damper can lead to such beam losses. Whereas these failures were already studied in the past, other unexpected beam loss mechanisms were observed after the LHC start-up: so-called (un)identified falling objects (UFOs), which are believed to be micrometer-sized m...

  14. ITER fast ion collective Thomson scattering, conceptual design of 60 GHz system

    International Nuclear Information System (INIS)

    Meo, F.; Bindslev, H.; Korsholm, S.B.

    2007-08-01

    The collective Thomson scattering diagnostic for ITER at the 60 GHz range is capable of measuring the fast ion distribution parallel and perpendicular to the magnetic field at different radial locations simultaneously. The design is robust technologically with no moveable components near the plasma. The fast ion CTS diagnostic consists of two separate systems. Each system has its own RF launcher and separate set of detectors. The first system measures the perpendicular component of the fast ion velocity distribution. It consists of radially directed RF launcher and receiver, both located in the equatorial port on the low field side (LFS). This system will be referred to by the acronym LFS-BS system referring to the location of the receiver and the fact that it measures backscattered radiation. The second part of the CTS diagnostic measures the parallel component of the fast ion distribution. It consists of an RF launcher located in the mid-plane port on the LFS and a receiver mounted on the inner vacuum vessel wall that views the plasma from between two blanket modules. This system will be referred to as HFS-FS referring to the location of the receivers and that they measure forward scattered radiation. The design of both LFS-BS and HFS-FS receivers is aimed at measuring at different spatial locations simultaneously with no moveable components near the plasma. This report is a preliminary study of the hardware design and engineering constraints for this frequency range. Section 2 conceptually describes the two systems and their main components. Section 3 clarifies the impact of design parameters such as beam widths and scattering angle on the CTS measurements. With this in hand, the ITER measurement requirements are translated into constraints on the CTS system designs. An important result in this section is that systems can be designed inside these constraints. Section 4 outlines the technical feasibility and describes in more detail the design and the engineering

  15. Feasibility Analysis and Prototyping of a Fast Autonomous Recon system

    Science.gov (United States)

    2017-06-01

    these systems is a gasoline or jet propellant fueled engine. a. ScanEagle The ScanEagle UAS designed for ISR missions on land or at sea (Insitu...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release. Distribution is unlimited. FEASIBILITY...ANALYSIS AND PROTOTYPING OF A FAST AUTONOMOUS RECON SYSTEM by Marcus A. Torres June 2017 Thesis Advisor: Oleg A. Yakimenko Second Reader

  16. Fast sweeping methods for hyperbolic systems of conservation laws at steady state II

    Science.gov (United States)

    Engquist, Björn; Froese, Brittany D.; Tsai, Yen-Hsi Richard

    2015-04-01

    The idea of using fast sweeping methods for solving stationary systems of conservation laws has previously been proposed for efficiently computing solutions with sharp shocks. We further develop these methods to allow for a more challenging class of problems including problems with sonic points, shocks originating in the interior of the domain, rarefaction waves, and two-dimensional systems. We show that fast sweeping methods can produce higher-order accuracy. Computational results validate the claims of accuracy, sharp shock curves, and optimal computational efficiency.

  17. PSR extraction kicker system improvements

    International Nuclear Information System (INIS)

    Hardek, T.W.

    1991-01-01

    A program to improve the reliability of hardware required to operate the Los Alamos Proton Storage Ring has been under way for the past three years. The extraction kicker system for the PSR was identified as one candidate for improvement. Pulse modulators produce 50kV pulses 360 nsec in length at up to 24-Hz pulse repetition rate and drive two 4-meter-long stripline electrodes. Sources of difficulty with this system included short width switch tube lifetime, drive cable electrical breakdown, high-voltage connector failure, and occasional electrode breakdown. This paper discusses modifications completed on this system to correct these difficulties. 2 refs., 3 figs

  18. Reliability analysis of 2400 MWth gas-cooled fast reactor natural circulation decay heat removal system

    International Nuclear Information System (INIS)

    Marques, M.; Bassi, C.; Bentivoglio, F.

    2012-01-01

    In support to a PSA (Probability Safety Assessment) performed at the design level on the 2400 MWth Gas-cooled Fast Reactor, the functional reliability of the decay heat removal system (DHR) working in natural circulation has been estimated in two transient situations corresponding to an 'aggravated' Loss of Flow Accident (LOFA) and a Loss of Coolant Accident (LOCA). The reliability analysis was based on the RMPS methodology. Reliability and global sensitivity analyses use uncertainty propagation by Monte Carlo techniques. The DHR system consists of 1) 3 dedicated DHR loops: the choice of 3 loops (3*100% redundancy) is made in assuming that one could be lost due to the accident initiating event (break for example) and that another one must be supposed unavailable (single failure criterion); 2) a metallic guard containment enclosing the primary system (referred as close containment), not pressurized in normal operation, having a free volume such as the fast primary helium expansion gives an equilibrium pressure of 1.0 MPa, in the first part of the transient (few hours). Each dedicated DHR loop designed to work in forced circulation with blowers or in natural circulation, is composed of 1) a primary loop (cross-duct connected to the core vessel), with a driving height of 10 meters between core and DHX mid-plan; 2) a secondary circuit filled with pressurized water at 1.0 MPa (driving height of 5 meters for natural circulation DHR); 3) a ternary pool, initially at 50 C. degrees, whose volume is determined to handle one day heat extraction (after this time delay, additional measures are foreseen to fill up the pool). The results obtained on the reliability of the DHR system and on the most important input parameters are very different from one scenario to the other showing the necessity for the PSA to perform specific reliability analysis of the passive system for each considered scenario. The analysis shows that the DHR system working in natural circulation is

  19. Microcontroller based two axis microtron beam extraction system

    International Nuclear Information System (INIS)

    Ashoka, H.; Jathar, M.; Meshram, V.; Rao, Nageswara

    2009-01-01

    Microtron is an electron accelerator which is used to accelerate the electron beam. The Microtron consists of electro magnet with two poles separated by yoke for completion of path for magnetic flux lines. A compact Microtron capable of accelerating electrons up to 12 MeV has been developed in RRCAT. The beam from the Microtron has to be extracted from various orbits depending upon the user requirement (X-Y stage is built with an accuracy of 100 μm). This paper describes the design and development of microcontroller based two axis beam extraction system for Microtron, with a resolution of 50 μm to position the extraction tube with respect to selected orbit. Two axis motion controller is developed using current controlled micro-stepping driver mechanism, which uses Bipolar Chopper Drive for driving stepper motors. Each phase has 2A continuous driving capability. The system is provided with user selectable controls like speed, steps, direction, and mode. This system is provided with RS-232 interface, to accept commands from PC. This system also has local keyboard and LCD interface to use in Stand-alone mode (local Mode). (author)

  20. A simple and rapid infrared-assisted self enzymolysis extraction method for total flavonoid aglycones extraction from Scutellariae Radix and mechanism exploration.

    Science.gov (United States)

    Wang, Liping; Duan, Haotian; Jiang, Jiebing; Long, Jiakun; Yu, Yingjia; Chen, Guiliang; Duan, Gengli

    2017-09-01

    A new, simple, and fast infrared-assisted self enzymolysis extraction (IRASEE) approach for the extraction of total flavonoid aglycones (TFA) mainly including baicalein, wogonin, and oroxylin A from Scutellariae Radix is presented to enhance extraction yield. Extraction enzymolysis temperature, enzymolysis liquid-to-solid ratio, enzymolysis pH, enzymolysis time and infrared power, the factors affecting IRASEE procedure, were investigated in a newly designed, temperature-controlled infrared-assisted extraction (TC-IRAE) system to acquire the optimum analysis conditions. The results illustrated that IRASEE possessed great advantages in terms of efficiency and time compared with other conventional extraction techniques. Furthermore, the mechanism of IRASEE was preliminarily explored by observing the microscopic change of the samples surface structures, studying the main chemical compositions change of the samples before and after extraction and investigating the kinetics and thermodynamics at three temperature levels during the IRASEE process. These findings revealed that IRASEE can destroy the surface microstructures to accelerate the mass transfer and reduce the activation energy to intensify the chemical process. This integrative study presents a simple, rapid, efficient, and environmental IRASEE method for TFA extraction which has promising prospects for other similar herbal medicines. Graphical Abstract ᅟ.

  1. Development of fast neutron radiography system based on portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th [Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Phayathai Rd., Patumwan, Bangkok, THAILAND 10330 (Thailand)

    2016-01-22

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  2. Fast probing of glucose and fructose in plant tissues via plasmonic affinity sandwich assay with molecularly-imprinted extraction microprobes.

    Science.gov (United States)

    Muhammad, Pir; Liu, Jia; Xing, Rongrong; Wen, Yanrong; Wang, Yijia; Liu, Zhen

    2017-12-01

    Determination of specific target compounds in agriculture food and natural plant products is essential for many purposes; however, it is often challenging due to the complexity of the sample matrices. Herein we present a new approach called plasmonic affinity sandwich assay for the facile and rapid probing of glucose and fructose in plant tissues. The approach mainly relies on molecularly imprinted plasmonic extraction microprobes, which were prepared on gold-coated acupuncture needles via boronate affinity controllable oriented surface imprinting with the target monosaccharide as the template molecules. An extraction microprobe was inserted into plant tissues under investigation, which allowed for the specific extraction of glucose or fructose from the tissues. The glucose or fructose molecules extracted on the microprobe were labeled with boronic acid-functionalized Raman-active silver nanoparticles, and thus affinity sandwich complexes were formed on the microprobes. After excess Raman nanotags were washed away, the microprobe was subjected to Raman detection. Upon being irradiated with a laser beam, surface plasmon on the gold-coated microprobes was generated, which further produced plasmon-enhanced Raman scattering of the silver-based nanotags and thereby provided sensitive detection. Apple fruits, which contain abundant glucose and fructose, were used as a model of plant tissues. The approach exhibited high specificity, good sensitivity (limit of detection, 1 μg mL -1 ), and fast speed (the whole procedure required only 20 min). The spatial distribution profiles of glucose and fructose within an apple were investigated by the developed approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Current status of feasibility studies on commercialized fuel cycle system for Fast Breeder Reactor

    International Nuclear Information System (INIS)

    Ojima, Hisao; Nagaoki, Yoshihiro

    2000-01-01

    A 'Feasibility Studies on Commercialized Fast Breeder Reactor Cycle System' is underway at the Japan Nuclear Cycle Development Institute (JNC). The study will select the promising concepts with their R and D tasks in order to commercialize the fast breeder reactor (FBR) cycle system. The feasibility studies (F/S) have to present surveyed and screened various relevant technologies, and defined the design requirement of the commercialized fuel cycle system for FBR. The promising technical options are being evaluated and conceptual designs are being examined. At the end of JFY2000, several candidate concepts of the commercialized FBR cycle system will be proposed. (author)

  4. Breeding description for fast reactors and symbiotic reactor systems

    International Nuclear Information System (INIS)

    Hanan, N.A.

    1979-01-01

    A mathematical model was developed to provide a breeding description for fast reactors and symbiotic reactor systems by means of figures of merit type quantities. The model was used to investigate the effect of several parameters and different fuel usage strategies on the figures of merit which provide the breeding description. The integrated fuel cycle model for a single-reactor is reviewed. The excess discharge is automatically used to fuel identical reactors. The resulting model describes the accumulation of fuel in a system of identical reactors. Finite burnup and out-of-pile delays and losses are treated in the model. The model is then extended from fast breeder park to symbiotic reactor systems. The asymptotic behavior of the fuel accumulation is analyzed. The asymptotic growth rate appears as the largest eigenvalue in the solution of the characteristic equations of the time dependent differential balance equations for the system. The eigenvector corresponding to the growth rate is the core equilibrium composition. The analogy of the long-term fuel cycle equations, in the framework of this model, and the neutron balance equations is explored. An eigenvalue problem adjoint to the one generated by the characteristic equations of the system is defined. The eigenvector corresponding to the largest eigenvalue, i.e. to the growth rate, represents the ''isotopic breeding worths.'' Analogously to the neutron adjoint flux it is shown that the isotopic breeding worths represent the importance of an isotope for breeding, i.e. for the growth rate of a system

  5. Design of fast tuning elements for the ITER ICH system

    International Nuclear Information System (INIS)

    Swain, D.W.; Goulding, R.H.

    1996-05-01

    The coupling between the ion cyclotron (IC) antenna and the ITER plasma (as expressed by the load resistance the antenna sees) will experience relatively fast variations due to plasma edge profile modifications. If uncompensated, these will cause an increase in the amount of power reflected back to the transmitter and ultimately a decrease in the amount of radio frequency (rf) power to the plasma caused by protective suppression of the amount of rf power generated by the transmitter. The goals of this task were to study several alternate designs for a tuning and matching (T ampersand M) system and to recommend some research and development (R ampersand D) tasks that could be carried out to test some of the most promising concepts. Analyses of five different T ampersand M configurations are presented in this report. They each have different advantages and disadvantages, and the choice among them must be made depending on the requirements for the IC system. Several general conclusions emerge from our study: The use of a hybrid splitter as a passive reflected-power dump [''edge localized mode (ELM)-dump''] appears very promising; this configuration will protect the rf power sources from reflected power during changes in plasma loading due to plasma motion or profile changes (e.g., ELM- induced changes in the plasma scrape-off region) and requires no active control of the rf system. Trade-offs between simplicity of design and capability of the system must be made. Simple system designs with few components near the antenna either have high voltages over considerable distances of transmission lines, or they are not easily tuned to operate at different frequencies. Designs using frequency shifts and/or fast tuning elements can provide fast matching over a wide range of plasma loading; however, the designs studied here require components near the antenna, complicating assembly and maintenance. Capacitor-tuned resonant systems may offer a good compromise

  6. Evaluation of degree of readsorption of radionuclides during sequential extraction in soil: comparison between batch and dynamic extraction systems

    DEFF Research Database (Denmark)

    Petersen, Roongrat; Hansen, Elo Harald; Hou, Xiaolin

    . However, the techniques have an important problem with redistribution as a result of readsorption of dissolved analytes onto the remaining solids phases during extraction. Many authors have demonstrated the readsorption problem and inaccuracy from it. In our previous work, a dynamic extraction system......Sequential extraction techniques have been widely used to fractionate metals in solid samples (soils, sediments, solid wastes, etc.) due to their leachability. The results are useful for obtaining information about bioavailability, potential mobility and transport of element in natural environments...... developed in our laboratory for heavy metal fractionation has shown the reduction of readsorption problem in comparison with the batch techniques. Moreover, the system shows many advantages over the batch system such as speed of extraction, simple procedure, fully automatic, less risk of contamination...

  7. Establishment of a Fast Chemical Identification System for screening of counterfeit drugs of macrolide antibiotics.

    Science.gov (United States)

    Hu, Chang-Qin; Zou, Wen-Buo; Hu, Wang-Sheng; Ma, Xiao-Kang; Yang, Min-Zhi; Zhou, Shi-Lin; Sheng, Jin-Fang; Li, Yuan; Cheng, Shuang-Hong; Xue, Jing

    2006-01-23

    A Fast Chemical Identification System (FCIS) consisting of two colour reactions based on functional groups in molecules of macrolide antibiotics and two TLC methods was developed for screening of fake macrolide drugs. The active ingredients could be extracted from their oral preparations by absolute alcohol. Sulfuric acid reaction as a common reaction of macrolides was first used to distinguish the macrolides from other types of drugs and then 16-membered macrolides and 14-membered ones were distinguished by potassium permanganate reactions depending on the time of loss of colour in the test solution; after which a TLC method carried out on a GF(254) plate (5 cm x 10 cm) was chosen to further identification of the macrolides. The mobile phase A consisting of ethyl acetate, hexane and ammonia (100:15:15, v/v) was used for the identification of 14-membered macrolides, and the mobile phase B consisting of trichloromethane, methanol and ammonia (100:5:1, v/v) was used for the identification of 16-membered ones. A suspected counterfeit macrolide preparation can be identified within 40 min. The system can be used under different conditions and has the virtues of robustness, simplicity and speed.

  8. Three-dimensional multi-terminal superconductive integrated circuit inductance extraction

    International Nuclear Information System (INIS)

    Fourie, Coenrad J; Wetzstein, Olaf; Kunert, Jürgen; Ortlepp, Thomas

    2011-01-01

    Accurate inductance calculations are critical for the design of both digital and analogue superconductive integrated circuits, and three-dimensional calculations are gaining importance with the advent of inductive biasing, inductive coupling and sky plane shielding for RSFQ cells. InductEx, an extraction programme based on the three-dimensional calculation software FastHenry, was proposed earlier. InductEx uses segmentation techniques designed to accurately model the geometries of superconductive integrated circuit structures. Inductance extraction for complex multi-terminal three-dimensional structures from current distributions calculated by FastHenry is discussed. Results for both a reflection plane modelling an infinite ground plane and a finite segmented ground plane that allows inductive elements to extend over holes in the ground plane are shown. Several SQUIDs were designed for and fabricated with IPHT's 1 kA cm −2 RSFQ1D niobium process. These SQUIDs implement a number of loop structures that span different layers, include vias, inductively coupled control lines and ground plane holes. We measured the loop inductance of these SQUIDs and show how the results are used to calibrate the layer parameters in InductEx and verify the extraction accuracy. We also show that, with proper modelling, FastHenry can be fast enough to be used for the extraction of typical RSFQ cell inductances.

  9. Fast and effective embedded systems design applying the ARM mbed

    CERN Document Server

    Toulson, Rob

    2012-01-01

    A hands-on introduction to the field of embedded systems; A focus on fast prototyping of embedded systems; All key embedded system concepts covered through simple and effective experimentation; An understanding of ARM technology, one of the world's leaders; A practical introduction to embedded C; Applies possibly the most accessible set of tools available in the embedded world.  This book is an introduction to embedded systems design, using the ARM mbed and C programming language as development tools. The mbed provides a compact, self-contained and low-cost hardware core, and the

  10. A Fast Vision System for Soccer Robot

    Directory of Open Access Journals (Sweden)

    Tianwu Yang

    2012-01-01

    Full Text Available This paper proposes a fast colour-based object recognition and localization for soccer robots. The traditional HSL colour model is modified for better colour segmentation and edge detection in a colour coded environment. The object recognition is based on only the edge pixels to speed up the computation. The edge pixels are detected by intelligently scanning a small part of whole image pixels which is distributed over the image. A fast method for line and circle centre detection is also discussed. For object localization, 26 key points are defined on the soccer field. While two or more key points can be seen from the robot camera view, the three rotation angles are adjusted to achieve a precise localization of robots and other objects. If no key point is detected, the robot position is estimated according to the history of robot movement and the feedback from the motors and sensors. The experiments on NAO and RoboErectus teen-size humanoid robots show that the proposed vision system is robust and accurate under different lighting conditions and can effectively and precisely locate robots and other objects.

  11. Integrating Information Extraction Agents into a Tourism Recommender System

    Science.gov (United States)

    Esparcia, Sergio; Sánchez-Anguix, Víctor; Argente, Estefanía; García-Fornes, Ana; Julián, Vicente

    Recommender systems face some problems. On the one hand information needs to be maintained updated, which can result in a costly task if it is not performed automatically. On the other hand, it may be interesting to include third party services in the recommendation since they improve its quality. In this paper, we present an add-on for the Social-Net Tourism Recommender System that uses information extraction and natural language processing techniques in order to automatically extract and classify information from the Web. Its goal is to maintain the system updated and obtain information about third party services that are not offered by service providers inside the system.

  12. Exploration of shallow subsurface resistivity structure using a portable TEM system: TEM-FAST prosystem; Kan`igata TEM ho sochi TEM-FAST prosystem ni yoru senbu hiteiko chosa

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Kumekawa, Y; Takasugi, S [GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)

    1997-05-27

    Discussions were given on effectiveness of the TEM-FAST ProSystem which is a portable TEM system developed recently for use in exploration of shallow subsurface resistivity. The system consists of a loop type antenna, the TEM-FAST as the main equipment, and a host computer, the host computer controlling the entire system. The system acquires transient response data in secondary induced magnetic fields lasting 4 {mu} sec to 1 m sec. The number of data is 5490 stacks in one measurement, and the data acquisition time is about three minutes. Measurements were carried out by using the TEM-FAST in the vicinity of a well, whose results were compared with those of electric logging, and discussions were given on them. Although the electric logging results had no data available for depths shallower than 35 m, the measurement results from the TEM-FAST were found highly harmonious with those of the electric logging. In addition, there were transmission and telephone lines in locations about 10 m away from the well during the measurement, but extremely high data quality was discovered. 6 refs., 7 figs., 1 tab.

  13. Refueling system for the gas-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Hawke, B.C.

    1980-05-01

    Criteria specifically related to the handling of Gas-Cooled Fast Breeder Reactor (GCFR) fuel are briefly reviewed, and the most significant requirements with which the refueling system must comply are discussed. Each component of the refueling system is identified, and a functional description of the fuel handling machine is presented. An illustrated operating sequence describing the various functions involved in a typical refueling cycle is presented. The design status of components and subsystems selected for conceptual development is reviewed, and anticipated refueling time frames are given

  14. Absolute calibration method for fast-streaked, fiber optic light collection, spectroscopy systems

    International Nuclear Information System (INIS)

    Johnston, Mark D.; Frogget, Brent; Oliver, Bryan Velten; Maron, Yitzhak; Droemer, Darryl W.; Crain, Marlon D.

    2010-01-01

    This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.

  15. Separation of rare earth metal using micro solvent extraction system

    International Nuclear Information System (INIS)

    Nishihama, S.; Tajiri, Y.; Yoshizuka, K.

    2005-01-01

    A micro solvent extraction system for the separation of rare earth metals has been investigated. The micro flow channel was fabricated on a PMMA plate. Extraction equilibrium was quickly achieved, without any mechanical mixing. The solvent extraction results obtained for the Pr/Sm binary solutions revealed that both rare earth metals are firstly extracted together. Following, the Pr is extracted in the organic solution and Sm remains in the aqueous phase. The phase separation can be successively achieved by contriving the cross section of the flow channel

  16. Effect of pKa on the extraction behavior of Am(III) in organo phosphorus acid and diglycolamide solvent system

    International Nuclear Information System (INIS)

    Swami, K. Rama; Antony, M.P.; Homi Bhabha National Institute, Mumbai; Kumaresan, R.; Nayak, P.K.; Venkatesan, K.A.

    2018-01-01

    A combination of neutral and acidic extractant has been proposed for the single-cycle separation of trivalent actinides from high-level liquid waste (HLLW). The nature of acidic extractant in the combined solvent formulation plays a profound role in deciding the extraction and stripping of trivalent actinides. Therefore, the extraction behavior of Am(III) in a solution of tetra-bis(2-ethylhexyl)-diglycolamide (TEHDGA) and acidic extractant (HA) was studied from nitric acid medium. The acidic extractants chosen were bis(2-ethylhexyl)phosphoric acid (HDEHP), bis(2-ethylhexyl)phosphonic acid (PC88A) and bis(2,4,4-trimethylpentyl)phosphinic acid (CYANEX-272) whose pKa values were 3.24, 4.51 and 6.37, respectively. The distribution ratio of Am(III) was measured as a function of various parameters such as concentration of nitric acid, TEHDGA, HA etc. The data were compared with those obtained in individual solvent systems namely 0.1 M TEHDGA/n-DD and HA/n-DD. Slope analysis of the extraction data indicated the synergic participation of both TEHDGA and HDEHP in the extraction of Am(III) at all acidities. However, antagonistic effect was observed at lower acidity when TEHDGA was mixed to PC88A or CYANEX-272 present in n-DD. Accordingly, a suitable mechanism has been proposed for the extraction of Am(III) at all acidities using these combined solvent formulation. Studies with fast reactor simulated high level liquid waste indicated that extraction of Am(III) was accompanied by co-extraction of lanthanides and unwanted metal ions such as Zr(IV), Mo(VI), Y(III) and Pd(II). However, addition of trans-1,2-diaminocyclohexane-N,N,N,N ' -tetraaceticacid (CyDTA) reduced the extraction of unwanted metal ions. Batch extraction and stripping studies indicated the possibility of using 0.1 M TEHDGA+0.25 M HDEHP in n-dodecane for the single cycle separation of Am(III) from FR-SHLLW.

  17. Fast Flux Test Facility core restraint system performance

    International Nuclear Information System (INIS)

    Hecht, S.L.; Trenchard, R.G.

    1990-02-01

    Characterizing Fast Flux Test Facility (FFTF) core restraint system performance has been ongoing since the first operating cycle. Characterization consists of prerun analysis for each core load, in-reactor and postirradiation measurements of subassembly withdrawal loads and deformations, and using measurement data to fine tune predictive models. Monitoring FFTF operations and performing trend analysis has made it possible to gain insight into core restraint system performance and head off refueling difficulties while maximizing component lifetimes. Additionally, valuable information for improved designs and operating methods has been obtained. Focus is on past operating experience, emphasizing performance improvements and avoidance of potential problems. 4 refs., 12 figs., 2 tabs

  18. Fast-Valving of Large Steam Turbine Units as a Means of Power System Security Enhancement

    OpenAIRE

    Bogdan Sobczak; Robert Rink; Rafał Kuczyński; Robert Trębski

    2014-01-01

    Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in an adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of a power system in the presence of an increase in wind and solar generation in the power syst...

  19. Sistem Gesture Accelerometer dengan Metode Fast Dynamic Time Warping (FastDTW

    Directory of Open Access Journals (Sweden)

    Sam Farisa Chaerul Haviana

    2016-01-01

    Full Text Available In the modern environment, the interaction between humans and computers require a more natural form of interaction. Therefore, it is important to be able to build a system that can meet these demands, such as by building a hand gesture recognition system or gesture to create a more natural form of interaction. This study aims to design a smartphone’s accelerometer gesture system as human computer interaction interfaces using FastDTW (Fast Dynamic Time Warping.The result of this study is form of gesture interaction which implemented in a system that can make the process of recognition of the human hand movements based on a smartphone accelerometer which generates a command to run the media player application functions as a case study. FastDTW as the development of Dynamic Time Warping method (DTW is able to compute faster than DTW and have an accuracy approaching DTW. From the test results, FastDTW show a fairly high degree of accuracy reached 86% and showed a better computing speed compared to DTW   Keywords: Human and Computer Interaction, Accelerometer-based gesture, FastDTW, Media player application function

  20. Extraction of lanthanide elements and bismuth in molten lithium chloride-liquid bismuth-lithium alloy system

    International Nuclear Information System (INIS)

    Harada, Makoto; Adachi, Motonari; Kai, Yuichi; Koike, Kenichi

    1987-01-01

    The equilibrium distributions of neodymium and samarium between molten LiCl and liquid Bi-Li alloy were measured in a wide range of Li-mole fraction in the alloy phase, X Li . These lanthanide elements were extracted through redox reactions. In high X Li range, X Li > 0.03, the distributions of neodymium and bismuth in the salt phase increased markedly. The anomalous increase is attributed to the formation of the compound comprized of Nd, Li, Bi and oxygen in the salt phase. The reaction processes in samarium and neodymium were very fast and the extraction rates are controlled by the diffusion processes of the solutes and metallic lithium. (author)

  1. Concept of a subcritical transmutation system with fast neutron spectrum and liquid fuel

    International Nuclear Information System (INIS)

    Tittelbach, S.

    2002-11-01

    The annual amount of nearly 9500 t of spent fuel from worldwide industrial nuclear energy utilization has to be disposed as high level waste. The retention of nuclear waste from the biosphere has to be assured until the radiological risk decreases to tolerable levels. The long-term radiological risk of spent fuel is dominated by actinide elements, i.e. plutonium, americium and curium. It is intended to reduce this amount of high level waste by Partitioning and Transmutation, so that the radiotoxicity of the disposed waste falls short of the reference value of fresh fuel decaying naturally after about thousand years. For this time period the retention of high level waste can be assured by technical means. The scope of this work is the design of a subcritical fast transmutation system with liquid metal cooling and liquid metal fuel. The lead bismuth eutectic has been choosen as the liquid metal coolant and fuel carrier. To dissolve at least 3 at% of transuran elements, a minimum fuel temperature of 600 C is required. The calculations were carried out with a fuel composition, which results from two plutonium recycling steps in a thorium fuel cycle. Two homogeneous and two heterogeneous blankets have been designed and evaluated leading to one preferred heterogeneous blanket design, which has been investigated in more detail. This blanket design merges the positive properties of a solid fuel system (better control of fuel and reactivity because of smaller and closed fuel volumina) and a liquid fuel system (continous charge and discharge or extraction of fission products). The blanket design is based on the core design of fast breeder liquid metal reactors. It consists of hexagonal fuel elements housing up to six annular shaped fuel cylinders. The hexagonal shape of the fuel elements leads to three fuel zones positioned concentrically around the central spallation target. There is a strong heterogeneous distribution of power and heat flux in this blanket design. Besides

  2. The second level trigger system of FAST

    CERN Document Server

    Martínez,G; Berdugo, J; Casaus, J; Casella, V; De Laere, D; Deiters, K; Dick, P; Kirkby, J; Malgeri, L; Mañá, C; Marín, J; Pohl, M; Petitjean, C; Sánchez, E; Willmott, C

    2009-01-01

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity π+ beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the μ+ lifetime, in order to determine the Fermi constant, Gf, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the π/μ decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  3. Quantification of steroid conjugates using fast atom bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Gaskell, S.J.

    1990-01-01

    Fast atom bombardment/mass spectrometry or liquid secondary ion mass spectrometry provides the capability for direct analysis of steroid conjugates (sulfates, glucuronides) without prior hydrolysis or derivatization. During the analysis of biologic extracts, limitations on the sensitivity of detection arise from the presence of co-extracted material which may suppress or obscure the analyte signal. A procedure is described for the quantitative determination of dehydroepiandrosterone sulfate in serum which achieved selective isolation of the analyte using immunoadsorption extraction and highly specific detection using tandem mass spectrometry. A stable isotope-labeled analog [( 2H2]dehydroepiandrosterone sulfate) was used as internal standard. Fast atom bombardment of dehydroepiandrosterone sulfate yielded abundant [M-H]- ions that fragmented following collisional activation to give HSO4-; m/z 97. During fast atom bombardment/tandem mass spectrometry of serum extracts, a scan of precursor ions fragmenting to give m/z 97 detected dehydroepiandrosterone sulfate and the [2H2]-labeled analog with a selectivity markedly superior to that observed using conventional mass spectrometry detection. Satisfactory agreement was observed between quantitative data obtained in this way and data obtained by gas chromatography/mass spectrometry of the heptafluorobutyrates of dehydroepiandrosterone sulfate and [2H2]dehydroepiandrosterone sulfate obtained by direct derivatization. 21 refs

  4. Technical Meeting on Existing and Proposed Experimental Facilities for Fast Neutron Systems. Presentations

    International Nuclear Information System (INIS)

    2013-01-01

    The objective of the TM on “Existing and proposed experimental facilities for fast neutron systems” is threefold: first, it is intended for presenting and exchanging information about existing and planned experimental facilities in support of the development of innovative fast neutron systems; second, it will allow to create a catalogue of existing and planned experimental facilities currently operated/developed within national or international fast reactors programmes; third, once a clear picture of the existing experimental infrastructures is defined, new experimental facilities will be discussed and proposed, on the basis of the identified R&D needs

  5. Sustainable thorium nuclear fuel cycles: A comparison of intermediate and fast neutron spectrum systems

    International Nuclear Information System (INIS)

    Brown, N.R.; Powers, J.J.; Feng, B.; Heidet, F.; Stauff, N.E.; Zhang, G.; Todosow, M.; Worrall, A.; Gehin, J.C.; Kim, T.K.; Taiwo, T.A.

    2015-01-01

    Highlights: • Comparison of intermediate and fast spectrum thorium-fueled reactors. • Variety of reactor technology options enables self-sustaining thorium fuel cycles. • Fuel cycle analyses indicate similar performance for fast and intermediate systems. • Reproduction factor plays a significant role in breeding and burn-up performance. - Abstract: This paper presents analyses of possible reactor representations of a nuclear fuel cycle with continuous recycling of thorium and produced uranium (mostly U-233) with thorium-only feed. The analysis was performed in the context of a U.S. Department of Energy effort to develop a compendium of informative nuclear fuel cycle performance data. The objective of this paper is to determine whether intermediate spectrum systems, having a majority of fission events occurring with incident neutron energies between 1 eV and 10 5 eV, perform as well as fast spectrum systems in this fuel cycle. The intermediate spectrum options analyzed include tight lattice heavy or light water-cooled reactors, continuously refueled molten salt reactors, and a sodium-cooled reactor with hydride fuel. All options were modeled in reactor physics codes to calculate their lattice physics, spectrum characteristics, and fuel compositions over time. Based on these results, detailed metrics were calculated to compare the fuel cycle performance. These metrics include waste management and resource utilization, and are binned to accommodate uncertainties. The performance of the intermediate systems for this self-sustaining thorium fuel cycle was similar to a representative fast spectrum system. However, the number of fission neutrons emitted per neutron absorbed limits performance in intermediate spectrum systems

  6. Sustainable thorium nuclear fuel cycles: A comparison of intermediate and fast neutron spectrum systems

    Energy Technology Data Exchange (ETDEWEB)

    Brown, N.R., E-mail: nbrown@bnl.gov [Brookhaven National Laboratory, Upton, NY (United States); Powers, J.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Feng, B.; Heidet, F.; Stauff, N.E.; Zhang, G. [Argonne National Laboratory, Argonne, IL (United States); Todosow, M. [Brookhaven National Laboratory, Upton, NY (United States); Worrall, A.; Gehin, J.C. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Kim, T.K.; Taiwo, T.A. [Argonne National Laboratory, Argonne, IL (United States)

    2015-08-15

    Highlights: • Comparison of intermediate and fast spectrum thorium-fueled reactors. • Variety of reactor technology options enables self-sustaining thorium fuel cycles. • Fuel cycle analyses indicate similar performance for fast and intermediate systems. • Reproduction factor plays a significant role in breeding and burn-up performance. - Abstract: This paper presents analyses of possible reactor representations of a nuclear fuel cycle with continuous recycling of thorium and produced uranium (mostly U-233) with thorium-only feed. The analysis was performed in the context of a U.S. Department of Energy effort to develop a compendium of informative nuclear fuel cycle performance data. The objective of this paper is to determine whether intermediate spectrum systems, having a majority of fission events occurring with incident neutron energies between 1 eV and 10{sup 5} eV, perform as well as fast spectrum systems in this fuel cycle. The intermediate spectrum options analyzed include tight lattice heavy or light water-cooled reactors, continuously refueled molten salt reactors, and a sodium-cooled reactor with hydride fuel. All options were modeled in reactor physics codes to calculate their lattice physics, spectrum characteristics, and fuel compositions over time. Based on these results, detailed metrics were calculated to compare the fuel cycle performance. These metrics include waste management and resource utilization, and are binned to accommodate uncertainties. The performance of the intermediate systems for this self-sustaining thorium fuel cycle was similar to a representative fast spectrum system. However, the number of fission neutrons emitted per neutron absorbed limits performance in intermediate spectrum systems.

  7. Fast filtering algorithm based on vibration systems and neural information exchange and its application to micro motion robot

    International Nuclear Information System (INIS)

    Gao Wa; Zha Fu-Sheng; Li Man-Tian; Song Bao-Yu

    2014-01-01

    This paper develops a fast filtering algorithm based on vibration systems theory and neural information exchange approach. The characters, including the derivation process and parameter analysis, are discussed and the feasibility and the effectiveness are testified by the filtering performance compared with various filtering methods, such as the fast wavelet transform algorithm, the particle filtering method and our previously developed single degree of freedom vibration system filtering algorithm, according to simulation and practical approaches. Meanwhile, the comparisons indicate that a significant advantage of the proposed fast filtering algorithm is its extremely fast filtering speed with good filtering performance. Further, the developed fast filtering algorithm is applied to the navigation and positioning system of the micro motion robot, which is a high real-time requirement for the signals preprocessing. Then, the preprocessing data is used to estimate the heading angle error and the attitude angle error of the micro motion robot. The estimation experiments illustrate the high practicality of the proposed fast filtering algorithm. (general)

  8. Advances in passive-remote and extractive Fourier transform infrared spectroscopic systems

    International Nuclear Information System (INIS)

    Demirgian, J.C.; Hammer, C.; Hwang, E.; Mao, Zhuoxiong.

    1993-01-01

    The Clean Air Act of 1990 requires the monitoring of air toxics including those from incinerator emissions. Continuous emission monitors (CEM) would demonstrate the safety of incinerators and address public concern about emissions of hazardous organic compounds. Fourier transform infrared (FTIR) spectroscopy can provide the technology for continuous emission monitoring of stacks. Stack effluent can be extracted and analyzed in less than one minute with conventional FTIR spectrometers. Passive-remote FTIR spectrometers can detect certain emission gases over 1 km away from a stack. The authors discuss advances in both extractive and passive-remote FTIR technology. Extractive systems are being tested with EPA protocols, which will soon replace periodic testing methods. Standard operating procedures for extractive systems are being developed and tested. Passive-remote FTIR spectrometers have the advantage of not requiring an extracted sample; however, they have less sensitivity. We have evaluated the ability of commercially available systems to detect fugitive plumes and to monitor carbon monoxide at a coal-fired power plant

  9. Investigation of fast initialization of spacecraft bubble memory systems

    Science.gov (United States)

    Looney, K. T.; Nichols, C. D.; Hayes, P. J.

    1984-01-01

    Bubble domain technology offers significant improvement in reliability and functionality for spacecraft onboard memory applications. In considering potential memory systems organizations, minimization of power in high capacity bubble memory systems necessitates the activation of only the desired portions of the memory. In power strobing arbitrary memory segments, a capability of fast turn on is required. Bubble device architectures, which provide redundant loop coding in the bubble devices, limit the initialization speed. Alternate initialization techniques are investigated to overcome this design limitation. An initialization technique using a small amount of external storage is demonstrated.

  10. A Robust and Fast Computation Touchless Palm Print Recognition System Using LHEAT and the IFkNCN Classifier

    Directory of Open Access Journals (Sweden)

    Haryati Jaafar

    2015-01-01

    Full Text Available Mobile implementation is a current trend in biometric design. This paper proposes a new approach to palm print recognition, in which smart phones are used to capture palm print images at a distance. A touchless system was developed because of public demand for privacy and sanitation. Robust hand tracking, image enhancement, and fast computation processing algorithms are required for effective touchless and mobile-based recognition. In this project, hand tracking and the region of interest (ROI extraction method were discussed. A sliding neighborhood operation with local histogram equalization, followed by a local adaptive thresholding or LHEAT approach, was proposed in the image enhancement stage to manage low-quality palm print images. To accelerate the recognition process, a new classifier, improved fuzzy-based k nearest centroid neighbor (IFkNCN, was implemented. By removing outliers and reducing the amount of training data, this classifier exhibited faster computation. Our experimental results demonstrate that a touchless palm print system using LHEAT and IFkNCN achieves a promising recognition rate of 98.64%.

  11. Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: Optimization of oil extraction method and analytical characterization.

    Science.gov (United States)

    Salvo, Andrea; La Torre, Giovanna Loredana; Di Stefano, Vita; Capocchiano, Valentina; Mangano, Valentina; Saija, Emanuele; Pellizzeri, Vito; Casale, Katia Erminia; Dugo, Giacomo

    2017-04-15

    A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio samples that entry in the European register of the products with P.D.O. In the present study the SPE procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision of the full analytical procedure was satisfactory and the mean recoveries were 92.8±0.3% and 96.6±0.1% for 25 and 50mgL -1 level of addition, respectively. Selected chromatographic conditions allowed a very fast squalene determination; in fact it was well separated in ∼0.54min with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels ranged from 55.45-226.34mgkg -1 . Comparing our results with those of other studies it emerges that squalene contents in P.D.O. Sicilian pistachio samples, generally, were higher than those measured for other samples of different geographic origins. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. A parallel architecture system dedicated to fast numerical calculus

    International Nuclear Information System (INIS)

    Harmanci, A.E.

    1982-04-01

    The project described here is the first result of a careful reflection oriented to the implementation of a machine intended for fast scientific computation, having in mind applications in the field of nuclear reactor safety. The selected structure is a data processing system of the MIMD type (Multiple Instruction, Multiple Data Stream). It is built by generalizing a basic cell constituted by associating an host processor and one or several processors dedicated to numerical computation, both operating alternatively on two areas of a common memory block. The principle of simultaneous operation of a large number of identical resources is used at every level of the structure. The system described here is hence modular and reconfigurable. The number of cells, the size and number of memory blocks may be chosen according to the needs. The communication between processors is carried out through the switching of the allocation of memory blocks. Moreover the numerical processors make the best use of private interconnections for synchronisation and fast data interchange. The present study devoted to the definition of the main hardware structures, will be followed by a simulation phase while suitable software tools will be developed [fr

  13. Econometric modelling of certain nuclear power systems based on thermal and fast breeder reactors

    International Nuclear Information System (INIS)

    Pavelescu, M.; Pioaru, C.; Ursu, I.

    1988-01-01

    Certain known economic analysis models for a LMFBR fast breeder and CANDU thermal solitary reactors are presented, based on the concepts of discounting and levelization. These models are subsequently utilized as a basis for establishing an original model for the econometric analysis of certain thermal reactor systems or/and fast breeder reactors. Case studies are subsequently conducted with the systems: 1-CANDU, 2-LMFBR, 3-CANDU + LMFBR which enables us to draw certain interesting conclusions for a long range nuclear power policy. (author)

  14. Y2K issues for real time computer systems for fast breeder test reactor

    International Nuclear Information System (INIS)

    Swaminathan, P.

    1999-01-01

    Presentation shows the classification of real time systems related to operation, control and monitoring of the fast breeder test reactor. Software life cycle includes software requirement specification, software design description, coding, commissioning, operation and management. A software scheme in supervisory computer of fast breeder test rector is described with the twenty years of experience in design, development, installation, commissioning, operation and maintenance of computer based supervision control system for nuclear installation with a particular emphasis on solving the Y2K problem

  15. Lane Detection in Video-Based Intelligent Transportation Monitoring via Fast Extracting and Clustering of Vehicle Motion Trajectories

    Directory of Open Access Journals (Sweden)

    Jianqiang Ren

    2014-01-01

    Full Text Available Lane detection is a crucial process in video-based transportation monitoring system. This paper proposes a novel method to detect the lane center via rapid extraction and high accuracy clustering of vehicle motion trajectories. First, we use the activity map to realize automatically the extraction of road region, the calibration of dynamic camera, and the setting of three virtual detecting lines. Secondly, the three virtual detecting lines and a local background model with traffic flow feedback are used to extract and group vehicle feature points in unit of vehicle. Then, the feature point groups are described accurately by edge weighted dynamic graph and modified by a motion-similarity Kalman filter during the sparse feature point tracking. After obtaining the vehicle trajectories, a rough k-means incremental clustering with Hausdorff distance is designed to realize the rapid online extraction of lane center with high accuracy. The use of rough set reduces effectively the accuracy decrease, which results from the trajectories that run irregularly. Experimental results prove that the proposed method can detect lane center position efficiently, the affected time of subsequent tasks can be reduced obviously, and the safety of traffic surveillance systems can be enhanced significantly.

  16. Fast simulation of the trigger system of the ATLAS detector at LHC

    International Nuclear Information System (INIS)

    Epp, B.; Ghete, V.M.; Kuhn, D.; Zhang, Y.J.

    2004-01-01

    The trigger system of the ATLAS detector aims to maximize the physics coverage and to be open to new and possibly unforeseen physics signatures. It is a multi-level system, composed from a hardware trigger at level-1, followed by the high-level-trigger (level-2 and event-filter). In order to understand its performance, to optimize it and to reduce its total cost, the trigger system requires a detailed simulation which is time- and resource-consuming. An alternative to the full detector simulation is a so-called 'fast simulation' which starts the analysis from particle level and replaces the full detector simulation and the detailed particle tracking with parametrized distributions obtained from the full simulation and/or a simplified detector geometry. The fast simulation offers a less precise description of trigger performance, but it is faster and less resource-consuming. (author)

  17. Evaluation of online accessed systems: example of qualitative research of Fast Addresses of GeaBios System

    Directory of Open Access Journals (Sweden)

    Aleš Klemen

    2006-01-01

    Full Text Available An efficient online information service user interface enables independent use of these online. Designers of the GeaBios Internet information system intended to evaluate the user-friendliness of their service »Fast adresses« (»Hitri naslovi«. In December 2003, as a research project for a graduation thesis, an evaluation of »Fast adresses« was conducted. The study consisted of 10 study participants performing assigned tasks and a survey of the same individuals. During the study research questions were developed as well as list of tasks to be assigned to the participants for the observations. Each observation was performed using a qualitative research paradigm. This paradigm was enhanced with an adaptation of Shneiderman’s (1998 questionnaire. Identified difficulties participants had in using »Fast adresses« fell into four types: (1 formulation of queries, (2 display of results, (3 the influence of the operating system, Windows, and, (4 the color and design of the display background and elements of the Web page. Results indicate that the difficulties encountered were not limited to the inappropriate design of the user interface, but also are attributable to user error.

  18. Feasibility study on commercialized fast reactor cycle systems. (1) Current status of the phase-II study

    International Nuclear Information System (INIS)

    Sagayama, Yutaka

    2005-01-01

    A feasibility study on commercialized fast reactors including related nuclear fuel cycle systems has been started from Japanese fiscal year 1999 by a Japanese joint project team of Japan Nuclear Cycle Development Institute and the Japan Atomic Power Company. This project aims at elucidating prominent fast reactor cycle systems that will respond to various needs of society in the future, together with economic competitiveness as future electricity supply systems. Challenging technology goals for the fast reactor cycle systems were defined in five targets: safety, economic competitiveness, reduction of environmental burden, efficient utilization of nuclear fuel resources and enhancement of nuclear non-proliferation. As the results of the feasibility study up to now, it is confirmed as the interim results that the combination of sodium-cooled fast reactors with oxide fuels, advanced aqueous reprocessing and simplified pellet fuel fabrication is highly suited to the development targets. The cost would be highly reduced by the adoption of innovative technologies, which feasibility is relatively clear and some R and D issues are now under progress. (author)

  19. Neighborhood fast food availability and fast food consumption.

    Science.gov (United States)

    Oexle, Nathalie; Barnes, Timothy L; Blake, Christine E; Bell, Bethany A; Liese, Angela D

    2015-09-01

    Recent nutritional and public health research has focused on how the availability of various types of food in a person's immediate area or neighborhood influences his or her food choices and eating habits. It has been theorized that people living in areas with a wealth of unhealthy fast-food options may show higher levels of fast-food consumption, a factor that often coincides with being overweight or obese. However, measuring food availability in a particular area is difficult to achieve consistently: there may be differences in the strict physical locations of food options as compared to how individuals perceive their personal food availability, and various studies may use either one or both of these measures. The aim of this study was to evaluate the association between weekly fast-food consumption and both a person's perceived availability of fast-food and an objective measure of fast-food presence - Geographic Information Systems (GIS) - within that person's neighborhood. A randomly selected population-based sample of eight counties in South Carolina was used to conduct a cross-sectional telephone survey assessing self-report fast-food consumption and perceived availability of fast food. GIS was used to determine the actual number of fast-food outlets within each participant's neighborhood. Using multinomial logistic regression analyses, we found that neither perceived availability nor GIS-based presence of fast-food was significantly associated with weekly fast-food consumption. Our findings indicate that availability might not be the dominant factor influencing fast-food consumption. We recommend using subjective availability measures and considering individual characteristics that could influence both perceived availability of fast food and its impact on fast-food consumption. If replicated, our findings suggest that interventions aimed at reducing fast-food consumption by limiting neighborhood fast-food availability might not be completely effective

  20. Fast Spectrum Reactors

    CERN Document Server

    Todd, Donald; Tsvetkov, Pavel

    2012-01-01

    Fast Spectrum Reactors presents a detailed overview of world-wide technology contributing to the development of fast spectrum reactors. With a unique focus on the capabilities of fast spectrum reactors to address nuclear waste transmutation issues, in addition to the well-known capabilities of breeding new fuel, this volume describes how fast spectrum reactors contribute to the wide application of nuclear power systems to serve the global nuclear renaissance while minimizing nuclear proliferation concerns. Readers will find an introduction to the sustainable development of nuclear energy and the role of fast reactors, in addition to an economic analysis of nuclear reactors. A section devoted to neutronics offers the current trends in nuclear design, such as performance parameters and the optimization of advanced power systems. The latest findings on fuel management, partitioning and transmutation include the physics, efficiency and strategies of transmutation, homogeneous and heterogeneous recycling, in addit...

  1. Fast methods for long-range interactions in complex systems. Lecture notes

    Energy Technology Data Exchange (ETDEWEB)

    Sutmann, Godehard; Gibbon, Paul; Lippert, Thomas (eds.)

    2011-10-13

    Parallel computing and computer simulations of complex particle systems including charges have an ever increasing impact in a broad range of fields in the physical sciences, e.g. in astrophysics, statistical physics, plasma physics, material sciences, physical chemistry, and biophysics. The present summer school, funded by the German Heraeus-Foundation, took place at the Juelich Supercomputing Centre from 6 - 10 September 2010. The focus was on providing an introduction and overview over different methods, algorithms and new trends for the computational treatment of long-range interactions in particle systems. The Lecture Notes contain an introduction into particle simulation, as well as five different fast methods, i.e. the Fast Multipole Method, Barnes-Hut Tree Method, Multigrid, FFT based methods, and Fast Summation using the non-equidistant FFT. In addition to introducing the methods, efficient parallelization of the methods is presented in detail. This publication was edited at the Juelich Supercomputing Centre (JSC) which is an integral part of the Institute for Advanced Simulation (IAS). The IAS combines the Juelich simulation sciences and the supercomputer facility in one organizational unit. It includes those parts of the scientific institutes at Forschungszentrum Juelich which use simulation on supercomputers as their main research methodology. (orig.)

  2. Fast methods for long-range interactions in complex systems. Lecture notes

    International Nuclear Information System (INIS)

    Sutmann, Godehard; Gibbon, Paul; Lippert, Thomas

    2011-01-01

    Parallel computing and computer simulations of complex particle systems including charges have an ever increasing impact in a broad range of fields in the physical sciences, e.g. in astrophysics, statistical physics, plasma physics, material sciences, physical chemistry, and biophysics. The present summer school, funded by the German Heraeus-Foundation, took place at the Juelich Supercomputing Centre from 6 - 10 September 2010. The focus was on providing an introduction and overview over different methods, algorithms and new trends for the computational treatment of long-range interactions in particle systems. The Lecture Notes contain an introduction into particle simulation, as well as five different fast methods, i.e. the Fast Multipole Method, Barnes-Hut Tree Method, Multigrid, FFT based methods, and Fast Summation using the non-equidistant FFT. In addition to introducing the methods, efficient parallelization of the methods is presented in detail. This publication was edited at the Juelich Supercomputing Centre (JSC) which is an integral part of the Institute for Advanced Simulation (IAS). The IAS combines the Juelich simulation sciences and the supercomputer facility in one organizational unit. It includes those parts of the scientific institutes at Forschungszentrum Juelich which use simulation on supercomputers as their main research methodology. (orig.)

  3. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  4. The second level trigger system of FAST

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, G. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)], E-mail: gustavo.martinez@ciemat.es; Barcyzk, A. [CERN, CH-1211 Geneva 23 (Switzerland); Berdugo, J.; Casaus, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Casella, C.; De Laere, S. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Deiters, K.; Dick, P. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Kirkby, J.; Malgeri, L. [CERN, CH-1211 Geneva 23 (Switzerland); Mana, C.; Marin, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Pohl, M. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Petitjean, C. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Sanchez, E.; Willmott, C. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)

    2009-10-11

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity {pi}{sup +} beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the {mu}{sup +} lifetime, in order to determine the Fermi constant, G{sub f}, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the {pi}/{mu} decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  5. Islamic fasting and oral health and diseases

    Directory of Open Access Journals (Sweden)

    A Javadzadeh Blouri

    2014-12-01

    Full Text Available Fasting is a religious obligation, which can be challenging for individuals with oral conditions due to its stringent code of conduct. Moreover, food abstinence during fasting can restrict oral feeding even further in patients whose nutrition has been already compromised. Previous research has mainly concentrated on oral hygiene and gum health, disregarding orodental conditions and diseases. This highlights the importance of further research in this regard. In this paper, we intended to clarify the correlation between fasting and oral injections, bleeding following tooth extraction, and brushing to overcome common misconceptions which indicate the breach of religious disciplines under such circumstances. We also aimed to determine the grave effects of fasting on health in case of severe immunological deficiencies, chronic oral ulcers and certain drug administration protocols for those with rigid religious beliefs.

  6. Fast imaging system on Tore Supra

    International Nuclear Information System (INIS)

    Geraud, A.; Salasca, S.; Verger, J. M.; Alarcon, T.; Agarici, G.; Bremond, S.; Chenevois, J. P.; Geynet, M.; Migozzi, J. B.; Reux, C.

    2009-01-01

    A new endoscope aiming at transferring the image of a poloidal section of the Tore Supra plasma to a fast camera able to record frames at a speed up to 4800 frames per second at full resolution, or much faster for a limited number of pixel, has been installed on Tore Supra. First movies showing the light emission associated to fast phenomena such as plasma start up, disruptions or gas and pellet injections have been produced.

  7. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    DEFF Research Database (Denmark)

    Thoisen, Christina Vinum; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive...... freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. Filters with the cryptophyte were frozen (−80 °C) and added phosphate buffer for extraction at 4 °C...... followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes. •Minimal usage of equipment and chemicals, and low labor costs. •Applicable for industrial and biological purposes....

  8. Simultaneous extraction and determination of trace amounts of diclofenac from whole blood using supported liquid membrane microextraction and fast Fourier transform voltammetry.

    Science.gov (United States)

    Mofidi, Zahra; Norouzi, Parviz; Sajadian, Masumeh; Ganjali, Mohammad Reza

    2018-04-01

    A novel, simple, and inexpensive analytical technique based on flat sheet supported liquid membrane microextraction coupled with fast Fourier transform stripping cyclic voltammetry on a reduced graphene oxide carbon paste electrode was used for the extraction and online determination of diclofenac in whole blood. First, diclofenac was extracted from blood samples using a polytetrafluoroethylene membrane impregnated with 1-octanol and then into an acceptor solution, subsequently it was oxidized on a carbon paste electrode modified with reduced graphene oxide nanosheets. The optimal values of the key parameters influencing the method were as follows: scan rate, 6 V/s; stripping potential, 200 mV; stripping time, 5 s; pH of the sample solution, 5; pH of the acceptor solution,7; and extraction time, 240 min. The calibration curves were plotted for the whole blood samples and the method was found to have a good linearity within the range of 1-25 μg/mL with a determination coefficient of 0.99. The limits of detection and quantification were 0.1 and 1.0 μg/mL, respectively. Using this coupled method, the extraction and determination were merged into one step. Accordingly, the speed of detection for sensitive determination of diclofenac in complex samples, such as blood, increased considerably. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Design and realization of a fast digital system for the protection of a linear accelerator

    International Nuclear Information System (INIS)

    Hamdi, A.

    2004-07-01

    The new generation of light sources based on SASE Free-Electron-Lasers driven by LINACs operate with electron beams with high beam currents and duty cycles. This is especially true for the superconducting machines like TTF 2 and the X-RAY FEL, under construction or planning at DESY. Elaborate fast protections systems are required not only to protect the machine from electron beams hitting and destroying the vacuum chamber, but also to prevent the machine from running at high loss levels, dangerous for components like the FEL undulator. This document presents the different protection systems currently under construction for TTF 2. The very fast systems, based on transmission measurements and distributed loss detection monitors, are described in detail. This description includes the fast electronics to collect and to transmit the different interlock and status signals: analog to digital converters, DSP and FPGA, interfaces, toroid protection system (TPS) card. The implementation and validation (simulation and tests) of the TPS card at DESY is presented

  10. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    OpenAIRE

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, S?ren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equip...

  11. MBA: a literature mining system for extracting biomedical abbreviations.

    Science.gov (United States)

    Xu, Yun; Wang, ZhiHao; Lei, YiMing; Zhao, YuZhong; Xue, Yu

    2009-01-09

    The exploding growth of the biomedical literature presents many challenges for biological researchers. One such challenge is from the use of a great deal of abbreviations. Extracting abbreviations and their definitions accurately is very helpful to biologists and also facilitates biomedical text analysis. Existing approaches fall into four broad categories: rule based, machine learning based, text alignment based and statistically based. State of the art methods either focus exclusively on acronym-type abbreviations, or could not recognize rare abbreviations. We propose a systematic method to extract abbreviations effectively. At first a scoring method is used to classify the abbreviations into acronym-type and non-acronym-type abbreviations, and then their corresponding definitions are identified by two different methods: text alignment algorithm for the former, statistical method for the latter. A literature mining system MBA was constructed to extract both acronym-type and non-acronym-type abbreviations. An abbreviation-tagged literature corpus, called Medstract gold standard corpus, was used to evaluate the system. MBA achieved a recall of 88% at the precision of 91% on the Medstract gold-standard EVALUATION Corpus. We present a new literature mining system MBA for extracting biomedical abbreviations. Our evaluation demonstrates that the MBA system performs better than the others. It can identify the definition of not only acronym-type abbreviations including a little irregular acronym-type abbreviations (e.g., ), but also non-acronym-type abbreviations (e.g., ).

  12. Using decision-tree classifier systems to extract knowledge from databases

    Science.gov (United States)

    St.clair, D. C.; Sabharwal, C. L.; Hacke, Keith; Bond, W. E.

    1990-01-01

    One difficulty in applying artificial intelligence techniques to the solution of real world problems is that the development and maintenance of many AI systems, such as those used in diagnostics, require large amounts of human resources. At the same time, databases frequently exist which contain information about the process(es) of interest. Recently, efforts to reduce development and maintenance costs of AI systems have focused on using machine learning techniques to extract knowledge from existing databases. Research is described in the area of knowledge extraction using a class of machine learning techniques called decision-tree classifier systems. Results of this research suggest ways of performing knowledge extraction which may be applied in numerous situations. In addition, a measurement called the concept strength metric (CSM) is described which can be used to determine how well the resulting decision tree can differentiate between the concepts it has learned. The CSM can be used to determine whether or not additional knowledge needs to be extracted from the database. An experiment involving real world data is presented to illustrate the concepts described.

  13. Technical Meeting on Existing and Proposed Experimental Facilities for Fast Neutron Systems. Working Material

    International Nuclear Information System (INIS)

    2013-01-01

    The objective of the TM on “Existing and proposed experimental facilities for fast neutron systems” was threefold: 1) presenting and exchanging information about existing and planned experimental facilities in support of the development of innovative fast neutron systems; 2) allow creating a catalogue of existing and planned experimental facilities currently operated/developed within national or international fast reactors programmes; 3) once a clear picture of the existing experimental infrastructures is defined, new experimental facilities are discussed and proposed, on the basis of the identified R&D needs

  14. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.

    Science.gov (United States)

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.

  15. A Fast LMMSE Channel Estimation Method for OFDM Systems

    Directory of Open Access Journals (Sweden)

    Zhou Wen

    2009-01-01

    Full Text Available A fast linear minimum mean square error (LMMSE channel estimation method has been proposed for Orthogonal Frequency Division Multiplexing (OFDM systems. In comparison with the conventional LMMSE channel estimation, the proposed channel estimation method does not require the statistic knowledge of the channel in advance and avoids the inverse operation of a large dimension matrix by using the fast Fourier transform (FFT operation. Therefore, the computational complexity can be reduced significantly. The normalized mean square errors (NMSEs of the proposed method and the conventional LMMSE estimation have been derived. Numerical results show that the NMSE of the proposed method is very close to that of the conventional LMMSE method, which is also verified by computer simulation. In addition, computer simulation shows that the performance of the proposed method is almost the same with that of the conventional LMMSE method in terms of bit error rate (BER.

  16. A general-purpose trigger processor system and its application to fast vertex trigger

    International Nuclear Information System (INIS)

    Hazumi, M.; Banas, E.; Natkaniec, Z.; Ostrowicz, W.

    1997-12-01

    A general-purpose hardware trigger system has been developed. The system comprises programmable trigger processors and pattern generator/samplers. The hardware design of the system is described. An application as a prototype of the very fast vertex trigger in an asymmetric B-factory at KEK is also explained. (author)

  17. Preliminary thermal analysis of grids for twin source extraction system

    International Nuclear Information System (INIS)

    Pandey, Ravi; Bandyopadhyay, Mainak; Chakraborty, Arun K.

    2017-01-01

    The TWIN (Two driver based Indigenously built Negative ion source) source provides a bridge between the operational single driver based negative ion source test facility, ROBIN in IPR and an ITER-type multi driver based ion source. The source is designed to be operated in CW mode with 180kW, 1MHz, 5s ON/600s OFF duty cycle and also in 5Hz modulation mode with 3s ON/20s OFF duty cycle for 3 such cycle. TWIN source comprises of ion source sub-assembly (consist of driver and plasma box) and extraction system sub-assembly. Extraction system consists of Plasma grid (PG), extraction grid (EG) and Ground grid (GG) sub assembly. Negative ion beams produced at plasma grid seeing the plasma side of ion source will receive moderate heat flux whereas the extraction grid and ground grid would be receiving majority of heat flux from extracted negative ion and co-extracted electron beams. Entire Co-extracted electron beam would be dumped at extraction grid via electron deflection magnetic field making the requirement of thermal and hydraulic design for extraction grid to be critical. All the three grids are made of OFHC Copper and would be actively water cooled keeping the peak temperature rise of grid surface within allowable limit with optimum uniformity. All the grids are to be made by vacuum brazing process where joint strength becomes crucial at elevated temperature. Hydraulic design must maintain the peak temperature at the brazing joint within acceptable limit

  18. Comparative analyses of diffusion coefficients for different extraction processes from thyme

    Directory of Open Access Journals (Sweden)

    Petrovic Slobodan S.

    2012-01-01

    Full Text Available This work was aimed to analyze kinetics and mass transfer phenomena for different extraction processes from thyme (Thymus vulgaris L. leaves. Different extraction processes with ethanol were studied: Soxhlet extraction and ultrasound-assisted batch extraction on the laboratory scale as well as pilot plant batch extraction with mixing. The extraction processes with ethanol were compared to the process of supercritical carbon dioxide extraction performed at 10 MPa and 40°C. Experimental data were analyzed by mathematical model derived from the Fick’s second law to determine and compare diffusion coefficients in the periods of constant and decreasing extraction rate. In the fast extraction period, values of diffusion coefficients were one to three orders of magnitude higher compared to those determined for the period of slow extraction. The highest diffusion coefficient was reported for the fast extraction period of supercritical fluid extraction. In the case of extraction processes with ethanol, ultrasound, stirring and extraction temperature increase enhanced mass transfer rate in the washing phase. On the other hand, ultrasound contributed the most to the increase of mass transfer rate in the period of slow extraction.

  19. Transient Behaviour of Interacting Extractive System

    International Nuclear Information System (INIS)

    El-Bialy, S.H.; Elsherbiny, A.E.

    2000-01-01

    The aim of this study is to investigate the dynamic behaviour of mixer-settler extractive system, which represents an interacting one. When a stimulus single is introduced to aqueous feed; the response of the aqueous phase of the first stage is considered as stimulus signals to both organic phase in the same stage and the aqueous phase of the second one. The response of the last phase represents-in turn- stimulus signals to both organic phase in the same stage and the aqueous phase in the next one. Mathematical model was derived for a system consisting of two stages in the cascade. The model assumed a continuous stirred tank reactor (CSTR) for mixer zone and variable holdups and flow rates of both aqueous and organic phases during operation. Non-linear equilibrium was considered. The obtained model-being non-linear- was linearized and Laplace transformation method was used to solve the model. The system constants are those corresponding to extraction of uranyl nitrate from 3 N nitric acid solution using Tbp dissolved in kerosene at 30% of the former. Stimulus-response test was carried out on the model by considering a step increase in solute concentration in aqueous feed stream. The system behaviour was tested at different values of operating parameters. First order behaviour for the first stage was observed and higher order for the rest of the system. A general relation for the difference in the power of the denominator and numerator of the transfer function of the i th stage was concluded for aqueous phase. The study showed that the system overdamp over the practical range of chosen parameters as explained from the values of transfer function roots

  20. Fast digital zooming system using directionally adaptive image interpolation and restoration.

    Science.gov (United States)

    Kang, Wonseok; Jeon, Jaehwan; Yu, Soohwan; Paik, Joonki

    2014-01-01

    This paper presents a fast digital zooming system for mobile consumer cameras using directionally adaptive image interpolation and restoration methods. The proposed interpolation algorithm performs edge refinement along the initially estimated edge orientation using directionally steerable filters. Either the directionally weighted linear or adaptive cubic-spline interpolation filter is then selectively used according to the refined edge orientation for removing jagged artifacts in the slanted edge region. A novel image restoration algorithm is also presented for removing blurring artifacts caused by the linear or cubic-spline interpolation using the directionally adaptive truncated constrained least squares (TCLS) filter. Both proposed steerable filter-based interpolation and the TCLS-based restoration filters have a finite impulse response (FIR) structure for real time processing in an image signal processing (ISP) chain. Experimental results show that the proposed digital zooming system provides high-quality magnified images with FIR filter-based fast computational structure.

  1. A System for Extracting Study Design Parameters from Nutritional Genomics Abstracts

    Directory of Open Access Journals (Sweden)

    Kelly Cassidy

    2013-06-01

    Full Text Available The extraction of study design parameters from biomedical journal articles is an important problem in natural language processing (NLP. Such parameters define the characteristics of a study, such as the duration, the number of subjects, and their profile. Here we present a system for extracting study design parameters from sentences in article abstracts. This system will be used as a component of a larger system for creating nutrigenomics networks from articles in the nutritional genomics domain. The algorithms presented consist of manually designed rules expressed either as regular expressions or in terms of sentence parse structure. A number of filters and NLP tools are also utilized within a pipelined algorithmic framework. Using this novel approach, our system performs extraction at a finer level of granularity than comparable systems, while generating results that surpass the current state of the art.

  2. A system for fast neutron radiography

    International Nuclear Information System (INIS)

    Klann, R.T.

    1997-01-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this system, objects as small as a coin and as large as a 19 liter container have been radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3 x 10[sup 10] neutrons/second with an average energy of 14. 5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available light-tight cassettes. The cassettes have been modified to include a thin sheet of plastic to produce protons from the neutron beam through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9 x 10[sup 7] n/cm[sup 2] to 3.8 x 10[sup 8] n/cm[sup 2] depending on the type of screen and film. The optimum source-to-film distance was found to be 150 cm. At this distance, the geometric unsharpness was determined to be approximately 2.2-2.3 mm and the smallest hole that could be resolved in a 1.25 cm thick sample had a diameter of 0.079 cm

  3. Effects of fast neutrons on chromatin: dependence on chromatin structure

    Energy Technology Data Exchange (ETDEWEB)

    Radu, L. [Dept. of Molecular Genetics, V. Babes National Inst., Bd. Timisoara, Bucharest (Romania); Constantinescu, B. [Dept. of Cyclotron, H. Hulubei National Inst., Bucharest (Romania); Gazdaru, D. [Dept. of Biophysics, Physics Faculty, Univ. of Bucharest (Romania)

    2002-07-01

    The effects of fast neutrons (10-100 Gy) on chromatin extracted from normal (liver of Wistar rats) and tumor (Walker carcinosarcoma maintained on Wistar rats) tissues were compared. The spectroscopic assays used were (i) chromatin intrinsic fluorescence, (ii) time-resolved fluorescence of chromatin-proflavine complexes, and (iii) fluorescence resonance energy transfer (FRET) between dansyl chloride and acridine orange coupled to chromatin. For both normal and tumor chromatin, the intensity of intrinsic fluorescence specific for acidic and basic proteins decreased with increasing dose. The relative contributions of the excited-state lifetime of proflavine bound to chromatin were reduced upon fast-neutron irradiation, indicating a decrease in the proportion of chromatin DNA available for ligand binding. The Forster energy transfer efficiencies were also modified by irradiation. These effects were larger for chromatin from tumor tissue. In the range 0-100 Gy, fast neutrons induced alterations in DNA and acidic and basic proteins, as well as in global chromatin structure. The radiosensitivity of chromatin extracted from tumor tissue seems to be higher than that of chromatin extracted from normal tissue, probably because of its higher euchromatin (loose)-heterochromatin (compact) ratio. (author)

  4. Effects of fast neutrons on chromatin: dependence on chromatin structure

    International Nuclear Information System (INIS)

    Radu, L.; Constantinescu, B.; Gazdaru, D.

    2002-01-01

    The effects of fast neutrons (10-100 Gy) on chromatin extracted from normal (liver of Wistar rats) and tumor (Walker carcinosarcoma maintained on Wistar rats) tissues were compared. The spectroscopic assays used were (i) chromatin intrinsic fluorescence, (ii) time-resolved fluorescence of chromatin-proflavine complexes, and (iii) fluorescence resonance energy transfer (FRET) between dansyl chloride and acridine orange coupled to chromatin. For both normal and tumor chromatin, the intensity of intrinsic fluorescence specific for acidic and basic proteins decreased with increasing dose. The relative contributions of the excited-state lifetime of proflavine bound to chromatin were reduced upon fast-neutron irradiation, indicating a decrease in the proportion of chromatin DNA available for ligand binding. The Forster energy transfer efficiencies were also modified by irradiation. These effects were larger for chromatin from tumor tissue. In the range 0-100 Gy, fast neutrons induced alterations in DNA and acidic and basic proteins, as well as in global chromatin structure. The radiosensitivity of chromatin extracted from tumor tissue seems to be higher than that of chromatin extracted from normal tissue, probably because of its higher euchromatin (loose)-heterochromatin (compact) ratio. (author)

  5. A Method for Extracting the Free Energy Surface and Conformational Dynamics of Fast-Folding Proteins from Single Molecule Photon Trajectories

    Science.gov (United States)

    2015-01-01

    Single molecule fluorescence spectroscopy holds the promise of providing direct measurements of protein folding free energy landscapes and conformational motions. However, fulfilling this promise has been prevented by technical limitations, most notably, the difficulty in analyzing the small packets of photons per millisecond that are typically recorded from individual biomolecules. Such limitation impairs the ability to accurately determine conformational distributions and resolve sub-millisecond processes. Here we develop an analytical procedure for extracting the conformational distribution and dynamics of fast-folding proteins directly from time-stamped photon arrival trajectories produced by single molecule FRET experiments. Our procedure combines the maximum likelihood analysis originally developed by Gopich and Szabo with a statistical mechanical model that describes protein folding as diffusion on a one-dimensional free energy surface. Using stochastic kinetic simulations, we thoroughly tested the performance of the method in identifying diverse fast-folding scenarios, ranging from two-state to one-state downhill folding, as a function of relevant experimental variables such as photon count rate, amount of input data, and background noise. The tests demonstrate that the analysis can accurately retrieve the original one-dimensional free energy surface and microsecond folding dynamics in spite of the sub-megahertz photon count rates and significant background noise levels of current single molecule fluorescence experiments. Therefore, our approach provides a powerful tool for the quantitative analysis of single molecule FRET experiments of fast protein folding that is also potentially extensible to the analysis of any other biomolecular process governed by sub-millisecond conformational dynamics. PMID:25988351

  6. FAST modularization framework for wind turbine simulation: full-system linearization

    Science.gov (United States)

    Jonkman, J. M.; Jonkman, B. J.

    2016-09-01

    The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations e.g. for design-standards-based loads analysis. Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system response and exploit well- established methods and tools for analyzing linear systems. This paper presents the development and verification of the new linearization functionality of the open-source engineering tool FAST v8 for land-based wind turbines, as well as the concepts and mathematical background needed to understand and apply it correctly.

  7. Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    International Nuclear Information System (INIS)

    Zarzycki, Pawel K.; Slaczka, Magdalena M.; Zarzycka, Magdalena B.; Wlodarczyk, Elzbieta; Baran, Michal J.

    2011-01-01

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds' feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5-8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  8. Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Zarzycki, Pawel K., E-mail: pawel_k_z@hotmail.com [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland); Slaczka, Magdalena M.; Zarzycka, Magdalena B.; Wlodarczyk, Elzbieta; Baran, Michal J. [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland)

    2011-03-04

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds' feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5-8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  9. System upgradation for surface mode negative ion beam extraction experiments in ROBIN

    International Nuclear Information System (INIS)

    Pandya, Kaushal; Bansal, Gourab; Soni, Jignesh

    2015-01-01

    ROBIN (Replica Of BATMAN source in India) is a replica of BATMAN source of IPP, Garching. Plasma production (inductively coupled, RF produced plasma), plasma diagnostic (langmuir probe, optical emission spectroscopy), negative ion beam extraction in volume mode with reduced extraction area of 2 cm 2 (4 apertures) using small bench top type power supply (10kV, 400mA), with increase extraction area of 73 cm 2 (146 apertures) and using actual power supplies (Extraction Power Supply System, EPSS (11kV, 35A), and Accelerator Power Supply System, APSS (35kV, 15A)) and beam diagnostic etc have been performed successfully in ROBIN. This paper will describe the details of the system upgradation for surface mode negative ion experiments and its performance in ROBIN

  10. A simple and fast method based on mixed hemimicelles coated magnetite nanoparticles for simultaneous extraction of acidic and basic pollutants.

    Science.gov (United States)

    Asgharinezhad, Ali Akbar; Ebrahimzadeh, Homeira

    2016-01-01

    One of the considerable and disputable areas in analytical chemistry is a single-step simultaneous extraction of acidic and basic pollutants. In this research, a simple and fast coextraction of acidic and basic pollutants (with different polarities) with the aid of magnetic dispersive micro-solid phase extraction based on mixed hemimicelles assembly was introduced for the first time. Cetyltrimethylammonium bromide (CTAB)-coated Fe3O4 nanoparticles as an efficient sorbent was successfully applied to adsorb 4-nitrophenol and 4-chlorophenol as two acidic and chlorinated aromatic amines as basic model compounds. Using a central composite design methodology combined with desirability function approach, the optimal experimental conditions were evaluated. The opted conditions were pH = 10; concentration of CTAB = 0.86 mmol L(-1); sorbent amount = 55.5 mg; sorption time = 11.0 min; no salt addition to the sample, type, and volume of the eluent = 120 μL methanol containing 5% acetic acid and 0.01 mol L(-1) HCl; and elution time = 1.0 min. Under the optimum conditions, detection limits and linear dynamic ranges were achieved in the range of 0.05-0.1 and 0.25-500 μg L(-1), respectively. The percent of extraction recoveries and relative standard deviations (n = 5) were in the range of 71.4-98.0 and 4.5-6.5, respectively. The performance of the optimized method was certified by coextraction of other acidic and basic compounds. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of the target analytes in various water samples, and satisfactory results were obtained.

  11. An introduction to fast dissolving oral thin film drug delivery systems: a review.

    Science.gov (United States)

    Kathpalia, Harsha; Gupte, Aasavari

    2013-12-01

    Many pharmaceutical companies are switching their products from tablets to fast dissolving oral thin films (OTFs). Films have all the advantages of tablets (precise dosage, easy administration) and those of liquid dosage forms (easy swallowing, rapid bioavailability). Statistics have shown that four out of five patients prefer orally disintegrating dosage forms over conventional solid oral dosages forms. Pediatric, geriatric, bedridden, emetic patients and those with Central Nervous System disorders, have difficulty in swallowing or chewing solid dosage forms. Many of these patients are non-compliant in administering solid dosage forms due to fear of choking. OTFs when placed on the tip or the floor of the tongue are instantly wet by saliva. As a result, OTFs rapidly hydrate and then disintegrate and/or dissolve to release the medication for local and/or systemic absorption. This technology provides a good platform for patent non- infringing product development and for increasing the patent life-cycle of the existing products. The application of fast dissolving oral thin films is not only limited to buccal fast dissolving system, but also expands to other applications like gastroretentive, sublingual delivery systems. This review highlights the composition including the details of various types of polymers both natural and synthetic, the different types of manufacturing techniques, packaging materials and evaluation tests for the OTFs.

  12. Fast reactor shield sensitivity studies for steel--sodium--iron systems

    International Nuclear Information System (INIS)

    Oblow, E.M.; Weisbin, C.R.

    1977-01-01

    A study was made of the adequacy of the current ENDF/B-IV sodium and iron neutron cross section data files for fast reactor shield design work. Experimental data from 21 fast reactor shield configurations containing large thicknesses of steel, sodium, and iron were analyzed with discrete ordinates calculations and sensitivity methods to assess the data files. This study represents the largest full-scale sensitivity analysis of benchmark quality experimental data to date. Included in the sensitivity studies were the results of the new cross section adjustment algorithms added to the FORSS code system. Conclusions were drawn about the need for more accurate data for sodium and iron elastic and discrete inelastic cross sections above 1 MeV and the values of the total cross section in the vicinity of important minima

  13. Utilizing a sequential injection system furnished with an extraction microcolumn as a novel approach for executing sequential extractions of metal species in solid samples

    DEFF Research Database (Denmark)

    Chomchoei, R.; Hansen, Elo Harald; Shiowatana, J.

    2007-01-01

    This communication presents a novel approach to perform sequential extraction of elements in solid samples by using a sequential injection (SI) system incorporating a specially designed extraction microcolumn. Based on the operation of the syringe pump, different modes of extraction are potentially...... that the system entails many advantages such as being fully automated, and besides being characterised by rapidity, ease of operation and robustness, it is less prone to risks of contamination and personal errors as encountered in traditional batch systems. Moreover, improvement of the precision and accuracy...... of the chemical fractionation of metal in solids as compared with previous reports are obtained. The system ensures that extraction is performed at designated pH values. Variation of sample weight to column volume ratios do not affect the amounts of extractable metals, nor do extraction flow rates ranging from 50...

  14. System cost - a criterion for the economic comparison of fast reactors

    International Nuclear Information System (INIS)

    Iliffe, C.E.

    1978-01-01

    The concept of electricity cost for a single station is derived from general considerations of profitability, including the effect of inflation. This derivation leads to the further one of system cost which is especially relevant to fast reactors in that plutonium is automatically allowed for. (author)

  15. Fast feedback system for energy and beam stabilization

    International Nuclear Information System (INIS)

    R. Dickson; V. Lebedev

    1999-01-01

    The electron beams being delivered to targets of the Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Accelerator Facility (Jefferson Lab) are plagued with undesirable positional and energy fluctuations. These fluctuations primarily occur at harmonics of the power line frequency (60, 120, 180, etc. hertz), and their cause is rooted in electromagnetic fields generated by accelerator electronic equipment. It is possible to largely nullify these deviations by applying real time corrections to electromagnets and RF verniers along the beam line. This concept has been successfully applied at Jefferson Lab by extensively modifying the existing Beam Position Monitor (BPM) system with the integration of an algorithm that computes correction signals targeted at the power line harmonics. Many of the modifications required were due to the existing CEBAF BPM system not having the data acquisition bandwidth needed for this type of feedback system. This paper will describe the techniques required to transform the CEBAF standard BPM system into a high speed practical fast feedback system that coexists with the large scale control system--the Experimental Physics and Industrial Control System (EPICS)--that runs the CEBAF accelerator in daily operation

  16. Fast coding of orientation in primary visual cortex.

    Directory of Open Access Journals (Sweden)

    Oren Shriki

    Full Text Available Understanding how populations of neurons encode sensory information is a major goal of systems neuroscience. Attempts to answer this question have focused on responses measured over several hundred milliseconds, a duration much longer than that frequently used by animals to make decisions about the environment. How reliably sensory information is encoded on briefer time scales, and how best to extract this information, is unknown. Although it has been proposed that neuronal response latency provides a major cue for fast decisions in the visual system, this hypothesis has not been tested systematically and in a quantitative manner. Here we use a simple 'race to threshold' readout mechanism to quantify the information content of spike time latency of primary visual (V1 cortical cells to stimulus orientation. We find that many V1 cells show pronounced tuning of their spike latency to stimulus orientation and that almost as much information can be extracted from spike latencies as from firing rates measured over much longer durations. To extract this information, stimulus onset must be estimated accurately. We show that the responses of cells with weak tuning of spike latency can provide a reliable onset detector. We find that spike latency information can be pooled from a large neuronal population, provided that the decision threshold is scaled linearly with the population size, yielding a processing time of the order of a few tens of milliseconds. Our results provide a novel mechanism for extracting information from neuronal populations over the very brief time scales in which behavioral judgments must sometimes be made.

  17. FAIR: A new fast trigger and readout bus system

    International Nuclear Information System (INIS)

    Ordine, A.; Boiano, A.; Zaghi, A.

    1998-01-01

    FAIR (FAst Intercrate Readout) is a synchronous ECL bus system dedicated to readout. It is based on a new trigger and readout hardware level protocol and on a new control system that learns how to setup and control modules. The hardware protocol along with the data structure allow both readout and event building at the same time at the rate of 22 ns/longword (1.44 Gbit/s) without the need of CPUs. It performs trigger management and full pipelining by using a multilevel FIFO structure. FAIR provides for a multi-crate front-end environment and uses an embedded serial network to accomplish front-end control and setup. The data transfer measured performances and the control system are presented in some detail

  18. A fast isotope switching system for high energy ions

    International Nuclear Information System (INIS)

    Niklaus, T.R.; Sie, S.H.; Suter, G.F.

    1998-01-01

    A fast bouncing system for the high energy end of an Accelerator Mass Spectrometry system has been devised for the AUSTRALIS at the CSIRO HIAF laboratory. Based on a method designed for excitation function measurements, it has been adapted as an isotope sequencer for AMS at the high energy side. In this scheme, different isotopes of the same energy are deflected off axis in the orbit plane by varying amounts at the entrance to the magnet and returned to the main axis at the exit by another deflection of the same magnitude in the same plane. Synchronised with the low energy side bouncer, the system will enable isotope ratios measurements with high precision by overcoming drifts in the source, beam transport and the accelerator itself

  19. Promising fast reactor systems in the feasibility study on commercialized FR cycle system

    International Nuclear Information System (INIS)

    Sakamoto, Y.; Kotake, S.; Enuma, Y.; Sagayama, Y.; Nishikawa, A.; Ando, M.

    2005-01-01

    The Feasibility Study on Commercialized Fast Reactor (FR) Cycle Systems is under way in order to propose prominent FR cycle systems that will respond to the diverse needs of society in the future. The design studies on various FR system concepts have been achieved and then the evaluations of potential to achieve the development targets have been carried out. Crucial issues have been found out for each FR system concept and their development plans for the key technologies are summarized as the roadmap. The characteristics and the differences in performances have been investigated. The crucial issues and the development periods have been clarified. Further investigation is now in progress. The promising concept will be proposed based on result of comparative evaluation at the end of the Phase II study. (authors)

  20. Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.

    Science.gov (United States)

    Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W

    2005-09-01

    A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.

  1. Semi-Global Filtering of Airborne LiDAR Data for Fast Extraction of Digital Terrain Models

    Directory of Open Access Journals (Sweden)

    Xiangyun Hu

    2015-08-01

    Full Text Available Automatic extraction of ground points, called filtering, is an essential step in producing Digital Terrain Models from airborne LiDAR data. Scene complexity and computational performance are two major problems that should be addressed in filtering, especially when processing large point cloud data with diverse scenes. This paper proposes a fast and intelligent algorithm called Semi-Global Filtering (SGF. The SGF models the filtering as a labeling problem in which the labels correspond to possible height levels. A novel energy function balanced by adaptive ground saliency is employed to adapt to steep slopes, discontinuous terrains, and complex objects. Semi-global optimization is used to determine labels that minimize the energy. These labels form an optimal classification surface based on which the points are classified as either ground or non-ground. The experimental results show that the SGF algorithm is very efficient and able to produce high classification accuracy. Given that the major procedure of semi-global optimization using dynamic programming is conducted independently along eight directions, SGF can also be paralleled and sped up via Graphic Processing Unit computing, which runs at a speed of approximately 3 million points per second.

  2. Fast and Adaptive Lossless On-Board Hyperspectral Data Compression System for Space Applications

    Science.gov (United States)

    Aranki, Nazeeh; Bakhshi, Alireza; Keymeulen, Didier; Klimesh, Matthew

    2009-01-01

    Efficient on-board lossless hyperspectral data compression reduces the data volume necessary to meet NASA and DoD limited downlink capabilities. The techniques also improves signature extraction, object recognition and feature classification capabilities by providing exact reconstructed data on constrained downlink resources. At JPL a novel, adaptive and predictive technique for lossless compression of hyperspectral data was recently developed. This technique uses an adaptive filtering method and achieves a combination of low complexity and compression effectiveness that far exceeds state-of-the-art techniques currently in use. The JPL-developed 'Fast Lossless' algorithm requires no training data or other specific information about the nature of the spectral bands for a fixed instrument dynamic range. It is of low computational complexity and thus well-suited for implementation in hardware, which makes it practical for flight implementations of pushbroom instruments. A prototype of the compressor (and decompressor) of the algorithm is available in software, but this implementation may not meet speed and real-time requirements of some space applications. Hardware acceleration provides performance improvements of 10x-100x vs. the software implementation (about 1M samples/sec on a Pentium IV machine). This paper describes a hardware implementation of the JPL-developed 'Fast Lossless' compression algorithm on a Field Programmable Gate Array (FPGA). The FPGA implementation targets the current state of the art FPGAs (Xilinx Virtex IV and V families) and compresses one sample every clock cycle to provide a fast and practical real-time solution for Space applications.

  3. Cost/schedule performance measurement system utilized on the Fast Flux Test Facility project

    International Nuclear Information System (INIS)

    Brown, R.K.; Frost, R.A.; Zimmerman, F.M.

    1976-01-01

    An Earned Value-Integrated Cost/Schedule Performance Measurement System has been applied to a major nonmilitary nuclear design and construction project. This system is similar to the Department of Defense Cost/Schedule Performance Measurement System. The project is the Fast Flux Test Facility (a Fuels and Materials test reactor for the Liquid Metal Fast Breeder Reactor Program) being built at the Hanford Engineering Development Laboratory, Richland, Washington, by Westinghouse Hanford Company for the U. S. Energy Research and Development Administration. Because the project was well into the construction phase when the Earned Value System was being considered, it was decided that the principles of DOD's Cost/Schedule Control System Criteria would be applied to the extent possible but no major changes in accounting practices or management systems were imposed. Implementation of this system enabled the following questions to be answered: For work performed, how do actual costs compare with the budget for that work. What is the impact of cost and schedule variances at an overall project level composed of different kinds of activities. Without the Earned Value system, these questions could be answered in a qualitative, subjective manner at best

  4. Numerical analyses on optimizing a heat pipe thermal management system for lithium-ion batteries during fast charging

    International Nuclear Information System (INIS)

    Ye, Yonghuang; Saw, Lip Huat; Shi, Yixiang; Tay, Andrew A.O.

    2015-01-01

    Thermal management is crucial for the operation of electric vehicles because lithium ion batteries are vulnerable to excessive heat generation during fast charging or other severe scenarios. In this work, an optimized heat pipe thermal management system (HPTMS) is proposed for fast charging lithium ion battery cell/pack. A numerical model is developed and comprehensively validated with experimental results. This model is then employed to investigate the thermal performance of the HPTMS under steady state and transient conditions. It is found that a cylinder vortex generator placed in front of the heat pipe condensers in the coolant stream improves the temperature uniformity. The uses of cooper heat spreaders and cooling fins greatly improve the performance of the thermal management system. Experiments and transient simulations of heat pipe thermal management system integrated with batteries prove that the improved HPTMS is capable for thermal management of batteries during fast charging. The air-cooled HPTMS is infeasible for thermal management of batteries during fast charging at the pack level due to the limitation of low specific heat capacity. - Highlights: • We develop a numerical model for optimizing a heat pipe thermal management system for fast charging batteries. • The numerical model is comprehensively validated with experimental data. • A cylinder vortex generator is placed at the inlet of the cooling stream to improve the temperature uniformity. • We validate the effectiveness of the optimized system with integration of prismatic batteries

  5. Moringa Oleifera leaf extract increases plasma antioxidant status associated with reduced plasma malondialdehyde concentration without hypoglycemia in fasting healthy volunteers.

    Science.gov (United States)

    Ngamukote, Sathaporn; Khannongpho, Teerawat; Siriwatanapaiboon, Marent; Sirikwanpong, Sukrit; Dahlan, Winai; Adisakwattana, Sirichai

    2016-12-29

    To investigate the effect of Moringa Oleifera leaf extract (MOLE) on plasma glucose concentration and antioxidant status in healthy volunteers. A randomized crossover design was used in this study. Healthy volunteers were randomly assigned to receive either 200 mL of warm water (10 cases) or 200 mL of MOLE (500 mg dried extract, 10 cases). Blood samples were drawn at 0, 30, 60, 90, and 120 min for measuring fasting plasma glucose (FPG), ferric reducing ability of plasma (FRAP), Trolox equivalent antioxidant capacity (TEAC) and malondialdehyde (MDA). FPG concentration was not signifificantly different between warm water and MOLE. The consumption of MOLE acutely improved both FRAP and TEAC, with increases after 30 min of 30 μmol/L FeSO 4 equivalents and 0.18 μmol/L Trolox equivalents, respectively. The change in MDA level from baseline was signifificantly lowered after the ingestion of MOLE at 30, 60, and 90 min. In addition, FRAP level was negatively correlated with plasma MDA level after an intake of MOLE. MOLE increased plasma antioxidant capacity without hypoglycemia in human. The consumption of MOLE may reduce the risk factors associated with chronic degenerative diseases.

  6. Coupled fast-thermal system at the 'RB' nuclear reactor

    International Nuclear Information System (INIS)

    Pesic, M.

    1987-04-01

    The results of the analyses of the possibility of the coupled fast-thermal system (CFTS) design at the 'RB' nuclear reactor are shown. As the proof of the theoretical analyses the first stage CFTS-1 has been designed, realized, and tested. The excellent agreement between the results of the CFTS-1 studies and the theoretical predictions opens a straight way to the second, the final stage - realization of the designed CFST at the 'RB' nuclear reactor. (author)

  7. Measurement of βeff in the coupled fast-thermal system HERBE

    International Nuclear Information System (INIS)

    Milosevic, M.; Pesic, M.; Avdic, S.

    1994-01-01

    The delayed neutron parameters and methods used in reactor safety studies are verified by measurement of the effective delayed neutron fraction β eff in the coupled fast-thermal system HERBE. The HERBE system is strongly heterogeneous. Methods applied in the calculation and interpretation of β eff measurement are described. The measured and calculated quantities and estimated uncertainties are presented. Agreement between the computation and measurement suggests the validity of the calculation method

  8. Performance of a demand controlled mechanical extract ventilation system for dwellings

    Directory of Open Access Journals (Sweden)

    I. Pollet

    2013-10-01

    Full Text Available The main aim of ventilation is to guarantee a good indoor air quality, related to the energy consumed for heating and fan(s. Active or passive heat recovery systems seem to focus on the reduction of heating consumption at the expense of fan electricity consumption and maintenance. In this study, demandcontrolled mechanical extract ventilation systems of Renson (DCV1 and DCV2, based on natural supply in the habitable rooms and mechanical extraction in the wet rooms (or even the bedrooms, was analysed for one year by means of multi-zone Contam simulations on a reference detached house and compared with standard MEV and mechanical extract ventilation systems with heat recovery (MVHR. To this end, IAQ, total energy consumption, CO2 emissions and total cost of the systems are determined. The results show that DCV systems with increased supply air flow rates or direct mechanical extract from bedrooms can significantly improve IAQ, while reducing total energy consumption compared to MEV. Applying DCV reduces primary heating energy consumption and yearly fan electricity consumption at most by 65% to 50% compared to MEV. Total operational energy costs and CO2 emissions of DCV are similar when compared to MVHR. Total costs of DCV systems over 15 years are smaller when compared to MVHR due to lower investment and maintenance costs.

  9. Systems principles of planning the net cost of oil and gas extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ryazanova, N I

    1979-01-01

    The automated system of calculation of ASPC ''oil extraction'' is developed in order to improve the existing system of planning of the oil extracting sector. The most complete expression of the systems construction of the plan is found in the section ''net cost and profit.'' Unity of the production process advances definite requirements for construction of the plan for net cost of oil and gas extraction as the model of this unified process. According to these requirements, the plan for net cost must be developed on the basis of interrelationship of the indicators of the plan for net cost within the section and with indicators of other sections of the plan, methodological unity and continuity of the methods of planning net cost by elements of outlays, articles of calculation and technical-economic factors, methodological continuity of regimes and stages of planning, as well as based on methodological continuity of the control levels. The listed requirements are principles for systems planning of the net cost of oil and gas extraction. These principles guarantee improvement in planning of net cost of oil and gas extraction according to the requirements made for the national economic planning.

  10. Carrier system for a plant extract or bioactive compound from a plant

    DEFF Research Database (Denmark)

    2018-01-01

    This invention relates to a carrier system for use in producing a beverage with a metered amount of plant extract or bioactive compound.......This invention relates to a carrier system for use in producing a beverage with a metered amount of plant extract or bioactive compound....

  11. Application of MEMS Accelerometers and Gyroscopes in Fast Steering Mirror Control Systems

    Directory of Open Access Journals (Sweden)

    Jing Tian

    2016-03-01

    Full Text Available In a charge-coupled device (CCD-based fast steering mirror (FSM tracking control system, high control bandwidth is the most effective way to enhance the closed-loop performance. However, the control system usually suffers a great deal from mechanical resonances and time delays induced by the low sampling rate of CCDs. To meet the requirements of high precision and load restriction, fiber-optic gyroscopes (FOGs are usually used in traditional FSM tracking control systems. In recent years, the MEMS accelerometer and gyroscope are becoming smaller and lighter and their performance have improved gradually, so that they can be used in a fast steering mirror (FSM to realize the stabilization of the line-of-sight (LOS of the control system. Therefore, a tentative approach to implement a CCD-based FSM tracking control system, which uses MEMS accelerometers and gyroscopes as feedback components and contains an acceleration loop, a velocity loop and a position loop, is proposed. The disturbance suppression of the proposed method is the product of the error attenuation of the acceleration loop, the velocity loop and the position loop. Extensive experimental results show that the MEMS accelerometers and gyroscopes can act the similar role as the FOG with lower cost for stabilizing the LOS of the FSM tracking control system.

  12. Factors influencing phase-disengagement rates in solvent-extraction systems employing tertiary amine extractants

    International Nuclear Information System (INIS)

    Moyer, B.A.; McDowell, W.J.

    1981-01-01

    The primary purpose of the present investigation was to examine the effects of amine size and structure on phase disengagement. Nine commercial tertiary amines were tested together with four laboratory-quality amines for uranium extraction and both organic-continuous (OC) and aqueous-continuous (AC) phase disengagement under Amex-type conditions. Synthetic acid sulfate solutions with and without added colloidal silica and actual ore leach solutions were used as the aqueous phases. Phase disengagement results were correlated with amine size and branching and solution wetting behavior on a silicate (glass) surface. The results suggest that the performance of some Amex systems may be improved by using branched chain tertiary amine extractants of higher molecular weight than are now normally used

  13. A Fast Adaptive Receive Antenna Selection Method in MIMO System

    Directory of Open Access Journals (Sweden)

    Chaowei Wang

    2013-01-01

    Full Text Available Antenna selection has been regarded as an effective method to acquire the diversity benefits of multiple antennas while potentially reduce hardware costs. This paper focuses on receive antenna selection. According to the proportion between the numbers of total receive antennas and selected antennas and the influence of each antenna on system capacity, we propose a fast adaptive antenna selection algorithm for wireless multiple-input multiple-output (MIMO systems. Mathematical analysis and numerical results show that our algorithm significantly reduces the computational complexity and memory requirement and achieves considerable system capacity gain compared with the optimal selection technique in the same time.

  14. Dynamics analysis of the fast-slow hydro-turbine governing system with different time-scale coupling

    Science.gov (United States)

    Zhang, Hao; Chen, Diyi; Wu, Changzhi; Wang, Xiangyu

    2018-01-01

    Multi-time scales modeling of hydro-turbine governing system is crucial in precise modeling of hydropower plant and provides support for the stability analysis of the system. Considering the inertia and response time of the hydraulic servo system, the hydro-turbine governing system is transformed into the fast-slow hydro-turbine governing system. The effects of the time-scale on the dynamical behavior of the system are analyzed and the fast-slow dynamical behaviors of the system are investigated with different time-scale. Furthermore, the theoretical analysis of the stable regions is presented. The influences of the time-scale on the stable region are analyzed by simulation. The simulation results prove the correctness of the theoretical analysis. More importantly, the methods and results of this paper provide a perspective to multi-time scales modeling of hydro-turbine governing system and contribute to the optimization analysis and control of the system.

  15. Microfluidic process monitor for industrial solvent extraction system

    Science.gov (United States)

    Gelis, Artem; Pereira, Candido; Nichols, Kevin Paul Flood

    2016-01-12

    The present invention provides a system for solvent extraction utilizing a first electrode with a raised area formed on its surface, which defines a portion of a microfluidic channel; a second electrode with a flat surface, defining another portion of the microfluidic channel that opposes the raised area of the first electrode; a reversibly deformable substrate disposed between the first electrode and second electrode, adapted to accommodate the raised area of the first electrode and having a portion that extends beyond the raised area of the first electrode, that portion defining the remaining portions of the microfluidic channel; and an electrolyte of at least two immiscible liquids that flows through the microfluidic channel. Also provided is a system for performing multiple solvent extractions utilizing several microfluidic chips or unit operations connected in series.

  16. The future of the Fast Breeder

    International Nuclear Information System (INIS)

    Lefevre, J.C.

    1990-01-01

    Fast Breeder Reactors (FBRs) can produce more fissile nuclei than they consume whilst, at the same time, generating energy using fast neutrons. By conversion of uranium isotope 238 into a fissionable fuel, FBRs provide over 60 times more energy than can be extracted from the uranium reserves by thermal reactors. Their development is therefore an essential objective in the next century, particularly for those industrialised countries that have little or no energy resources of their own. The European countries which have been engaged in the development of FBRs for more than 25 years have decided to collaborate in an advanced design, the European Fast Reactor (EFR) which uses the best of previous national projects and draws on extensive operating experience from FBR plants in Europe. The naturally safe characteristics and technological features of sodium-cooled Fast Reactors will be fully utilised in an EFR design which meets the same safety level as the Light Water Reactors (LWRs). Owing to technical progress and series construction effect, the EFR is expected to achieve competitiveness with contemporary LWRs with the higher capital cost of the Fast Reactor offset by its markedly lower fuel cycle cost. (author)

  17. Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

    Science.gov (United States)

    Li, Zhenjie; Li, Qiuju; Chang, Jinfan; Ma, Yichao; Liu, Peng; Wang, Zheng; Hu, Michael Y.; Zhao, Jiyong; Alp, E. E.; Xu, Wei; Tao, Ye; Wu, Chaoqun; Zhou, Yangfan

    2017-10-01

    A four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm2 and an absorption layer thickness of 110 μm. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. For the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

  18. The computerized reactor period measurement system for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1996-01-01

    The article simply introduces the hardware, principle, and software of the computerized reactor period measurement system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between fission yield and pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computerized measurement system makes the reactor period measurement into automatical and intelligent and also improves the speed and precision of period data on-line process

  19. Computer measurement system of reactor period for China fast burst reactor-II

    International Nuclear Information System (INIS)

    Zhao Wuwen; Jiang Zhiguo

    1997-01-01

    The author simply introduces the hardware, principle, and software of the reactor period computer measure system for China Fast Burst Reactor-II (CFBR-II). It also gives the relation between Fission yield and Pre-reactivity of CFBR-II reactor system of bared reactor with decoupled-component and system of bared reactor with multiple light-material. The computer measure system makes the reactor period measurement into automation and intellectualization and also improves the speed and precision of period data process on-line

  20. Fast Fingerprint Classification with Deep Neural Network

    DEFF Research Database (Denmark)

    Michelsanti, Daniel; Guichi, Yanis; Ene, Andreea-Daniela

    2018-01-01

    . In this work we evaluate the performance of two pre-trained convolutional neural networks fine-tuned on the NIST SD4 benchmark database. The obtained results show that this approach is comparable with other results in the literature, with the advantage of a fast feature extraction stage....

  1. Contribution to the modelization of liquid-liquid extraction systems. Application to metallic nitrate extraction by TBP in nitric medium

    International Nuclear Information System (INIS)

    Ly, J.

    1984-10-01

    The validity of theoretical expression for activity coefficients, in concentrated aqueous solution, proposed by Mikulin-Stokes-Robinson and Ryazanov-Vdovenko is confirmed by numerous tests. This allows a better control of the reactivity of chemicals in the extraction system: nitric aqueous solution-TBP organic solution used in nuclear hydrometallurgy. A reliable methodology is proposed for the study of metal extraction mechanism. Application to palladium (II) evidences extracted species in the organic phase. Influence of degradation product from extractant radiolysis on the behavior of this metallic element is effected. 187 refs [fr

  2. Interaction of Plant Extracts with Central Nervous System Receptors

    Directory of Open Access Journals (Sweden)

    Kenneth Lundstrom

    2017-02-01

    Full Text Available Background: Plant extracts have been used in traditional medicine for the treatment of various maladies including neurological diseases. Several central nervous system receptors have been demonstrated to interact with plant extracts and components affecting the pharmacology and thereby potentially playing a role in human disease and treatment. For instance, extracts from Hypericum perforatum (St. John’s wort targeted several CNS receptors. Similarly, extracts from Piper nigrum, Stephania cambodica, and Styphnolobium japonicum exerted inhibition of agonist-induced activity of the human neurokinin-1 receptor. Methods: Different methods have been established for receptor binding and functional assays based on radioactive and fluorescence-labeled ligands in cell lines and primary cell cultures. Behavioral studies of the effect of plant extracts have been conducted in rodents. Plant extracts have further been subjected to mood and cognition studies in humans. Results: Mechanisms of action at molecular and cellular levels have been elucidated for medicinal plants in support of standardization of herbal products and identification of active extract compounds. In several studies, plant extracts demonstrated affinity to a number of CNS receptors in parallel indicating the complexity of this interaction. In vivo studies showed modifications of CNS receptor affinity and behavioral responses in animal models after treatment with medicinal herbs. Certain plant extracts demonstrated neuroprotection and enhanced cognitive performance, respectively, when evaluated in humans. Noteworthy, the penetration of plant extracts and their protective effect on the blood-brain-barrier are discussed. Conclusion: The affinity of plant extracts and their isolated compounds for CNS receptors indicates an important role for medicinal plants in the treatment of neurological disorders. Moreover, studies in animal and human models have confirmed a scientific basis for the

  3. Dyeing of white and indigo dyed cotton fabrics with Mimosa tenuiflora extract

    Directory of Open Access Journals (Sweden)

    Gökhan Erkan

    2014-04-01

    Full Text Available Mimosa tenuiflora extract has been used in food industry as an additive and in textile and leather industry as a colorant. Two types of fabrics, ready to be dyed white and indigo dyed fabrics, were dyed with M. tenuiflora extract. The fabrics were mordanted after dyeing with six different metal salts. Colorimetric evaluations of fabrics were carried out by spectrophotometer. Colour fastness to washing, rubbing and light were performed. Colour strength of fabrics was calculated from Kubelka–Munk formula. Highest vividness (C∗ values were obtained by Ni mordant. Moderate fastness values were observed. However poor wet rubbing fastness values were observed in the case of indigo dyed fabrics due to lack of good wet rubbing fastness of indigo itself.

  4. Extraction of neutron spectral information from Bonner-Sphere data

    CERN Document Server

    Haney, J H; Zaidins, C S

    1999-01-01

    We have extended a least-squares method of extracting neutron spectral information from Bonner-Sphere data which was previously developed by Zaidins et al. (Med. Phys. 5 (1978) 42). A pulse-height analysis with background stripping is employed which provided a more accurate count rate for each sphere. Newer response curves by Mares and Schraube (Nucl. Instr. and Meth. A 366 (1994) 461) were included for the moderating spheres and the bare detector which comprise the Bonner spectrometer system. Finally, the neutron energy spectrum of interest was divided using the philosophy of fuzzy logic into three trapezoidal regimes corresponding to slow, moderate, and fast neutrons. Spectral data was taken using a PuBe source in two different environments and the analyzed data is presented for these cases as slow, moderate, and fast neutron fluences. (author)

  5. Design project of fast subcritical system 'Mala Lasta'; Idejno resenje brzog podkriticnog sistema Mala LASTA

    Energy Technology Data Exchange (ETDEWEB)

    Milosevic, M; Stefanovic, D; Popovic, D; Pesic, M; Zavaljevski, N; Nikolic, D; Arsenovic, M [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1988-10-15

    This report contains two parts. Part one covers the objective and fundamental elements for the choice of fast subcritical system 'Mala Lasta', review of the existing fast subcritical assemblies, and a description of the available domestic computer codes applied for calculating neutron reactor parameters. Comparison of results obtained by these codes for a number of existing subcritical assemblies was used for the choice of the design project described in part two of this report. It contains detailed description of the operating parameters of the chosen subcritical system based on the obtained calculated parameters.

  6. Software for Extracting 3D - MSSTs

    DEFF Research Database (Denmark)

    Somchaipeng, Kerawit; Sporring, Jon; Kreiborg, Sven

    2003-01-01

    The deep structure of an image is investigated, and a Multi-Scale Singularity Tree (MSST) is constructed based on the pair-wise annihilations of critical points. This report contains two main contributions. Firstly, we describe a fast, simple, and robust method of extracting feature lines from data...... sets of up to four dimen- sions, which we apply in order to extract critical paths from scale-spaces. Secondly, we investigate the extracting of MSSTs using either support regions or extrema partitions. Given an image, both methods produce a binary tree that mathematically represents the topological...

  7. Fuel reprocessing of the fast molten salt reactor: actinides et lanthanides extraction

    International Nuclear Information System (INIS)

    Jaskierowicz, S.

    2012-01-01

    The fuel reprocessing of the molten salt reactor (Gen IV concept) is a multi-steps process in which actinides and lanthanides extraction is performed by a reductive extraction technique. The development of an analytic model has showed that the contact between the liquid fuel LiF-ThF 4 and a metallic phase constituted of Bi-Li provide firstly a selective and quantitative extraction of actinides and secondly a quantitative extraction of lanthanides. The control of this process implies the knowledge of saline phase properties. Studies of the physico-chemical properties of fluoride salts lead to develop a technique based on potentiometric measurements to evaluate the fluoro-acidity of the salts. An acidity scale was established in order to classify the different fluoride salts considered. Another electrochemical method was also developed in order to determine the solvation properties of solutes in fluoride F- environment (and particularly ThF 4 by F-) in reductive extraction technique, a metallic phase is also involved. A method to prepare this phase was developed by electro-reduction of lithium on a bismuth liquid cathode in LiCl-LiF melt. This technique allows to accurately control the molar fraction of lithium introduced into the liquid bismuth, which is a main parameter to obtain an efficient extraction. (author)

  8. Model-Based Extracted Water Desalination System for Carbon Sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Dees, Elizabeth M. [General Electric Global Research Center, Niskayuna, NY (United States); Moore, David Roger [General Electric Global Research Center, Niskayuna, NY (United States); Li, Li [Pennsylvania State Univ., University Park, PA (United States); Kumar, Manish [Pennsylvania State Univ., University Park, PA (United States)

    2017-05-28

    Over the last 1.5 years, GE Global Research and Pennsylvania State University defined a model-based, scalable, and multi-stage extracted water desalination system that yields clean water, concentrated brine, and, optionally, salt. The team explored saline brines that ranged across the expected range for extracted water for carbon sequestration reservoirs (40,000 up to 220,000 ppm total dissolved solids, TDS). In addition, the validated the system performance at pilot scale with field-sourced water using GE’s pre-pilot and lab facilities. This project encompassed four principal tasks, in addition to Project Management and Planning: 1) identify a deep saline formation carbon sequestration site and a partner that are suitable for supplying extracted water; 2) conduct a techno-economic assessment and down-selection of pre-treatment and desalination technologies to identify a cost-effective system for extracted water recovery; 3) validate the downselected processes at the lab/pre-pilot scale; and 4) define the scope of the pilot desalination project. Highlights from each task are described below: Deep saline formation characterization The deep saline formations associated with the five DOE NETL 1260 Phase 1 projects were characterized with respect to their mineralogy and formation water composition. Sources of high TDS feed water other than extracted water were explored for high TDS desalination applications, including unconventional oil and gas and seawater reverse osmosis concentrate. Technoeconomic analysis of desalination technologies Techno-economic evaluations of alternate brine concentration technologies, including humidification-dehumidification (HDH), membrane distillation (MD), forward osmosis (FO), turboexpander-freeze, solvent extraction and high pressure reverse osmosis (HPRO), were conducted. These technologies were evaluated against conventional falling film-mechanical vapor recompression (FF-MVR) as a baseline desalination process. Furthermore, a

  9. DYEING SILK FABRICS WITH STINK BEAN POD (PARKIA SPECIOSA HASSK. NATURAL DYE IN THE COLOR FASTNESS AND UV PROTECTION

    Directory of Open Access Journals (Sweden)

    M. MASAE

    2017-07-01

    Full Text Available This paper describes natural dye extracted from stink bean pod (Parkia speciosa Hassk. which was dyed on the silk fabric. The mordants as aluminum potassium sulfate, iron chloride, sodium hydroxide and mud were used to dye fabric using three different dyeing methods: pre-mordanting, meta-mordanting and post-mordanting. The color fastness to washing, water, perspiration, light and crocking of the dyed samples was determined according to AATCC test methods. In this study the UV-protection properties on silk fabrics were investigated. The chemical functional groups of the dyes were characterized by Fourier transform infrared spectroscopy (FTIR. The results revealed that the dyeing silk fabrics with stink beans pod were fair to good fastness to washing and crocking and very poor to poor light fastness with the exception of samples mordanted with iron chloride. The water and perspiration fastness ratings were fair to good. Silk fabrics mordanted with iron chloride and dyed with stink bean usually showed good UV-protection levels even if undyed. These extracts gave polyphenolic, betalain dye and chlorophyll content. Therefore, it was suggested that stink bean pod has the potential in producing functional dyes that could be imparted into the silk dyeing natural colorant system.

  10. Birch Bark Dry Extract by Supercritical Fluid Technology: Extract Characterisation and Use for Stabilisation of Semisolid Systems

    Directory of Open Access Journals (Sweden)

    Markus Armbruster

    2017-03-01

    Full Text Available Triterpene compounds like betulin, betulinic acid, erythrodiol, oleanolic acid and lupeol are known for many pharmacological effects. All these substances are found in the outer bark of birch. Apart from its pharmacological effects, birch bark extract can be used to stabilise semisolid systems. Normally, birch bark extract is produced for this purpose by extraction with organic solvents. Employing supercritical fluid technology, our aim was to develop a birch bark dry extract suitable for stabilisation of lipophilic gels with improved properties while avoiding the use of toxic solvents. With supercritical carbon dioxide, three different particle formation methods from supercritical solutions have been tested. First, particle deposition was performed from a supercritical solution in an expansion chamber. Second, the Rapid Expansion of Supercritical Solutions (RESS method was used for particle generation. Third, a modified RESS-procedure, forming the particles directly into the thereby gelated liquid, was developed. All three methods gave yields from 1% to 5.8%, depending on the techniques employed. The triterpene composition of the three extracts was comparable: all three gave more stable oleogels compared to the use of an extract obtained by organic solvent extraction. Characterizing the rheological behaviour of these gels, a faster gelling effect was seen together with a lower concentration of the extract required for the gel formation with the supercritical fluid (SCF-extracts. This confirms the superiority of the supercritical fluid produced extracts with regard to the oleogel forming properties.

  11. Simulation of equilibrium distribution data in a solvent extraction system

    International Nuclear Information System (INIS)

    Mondal, S.; Giriyalkar, A.B.; Singh, A.K.; Singh, D.K.; Hubli, R.C.

    2014-01-01

    In hydrometallurgy, solvent extraction has been proved to be the purification method to recover metal in high-pure form from impure solution. Any solvent extraction process is complex and based on some operating parameters which always lure the scientists to model them. Operating parameters like aqueous to organic volume ratio and concentration of feed are related to required number of stages for a product with specific recovery. So to determine final feed concentration or aqueous to organic volume ratio for a specific extractant concentration, one needs to carry out a number of extraction experiments tediously supported by analysis. Here an attempt is being made to model the distribution of solute between organic and aqueous phases with minimum analytical and experimental support for any system. The model can predict the effect on solvent extraction for a change in the aqueous to organic volume ratio i.e. slope of operating line, percentage loading of solvent, feed concentration, solvent concentration, number of stages and in the process it can help in optimizing conditions for the best result from a solvent extraction system. Uranium-7% TBP in dodecane system was taken up to validate the model. The predicted values of the model was tallied against uranium distribution between aqueous and organic phases in a running mixer settler. The equation for operating line i.e. straight line is derived from O/A=1.5 and considering barren organic contains 2 ppm uranium: y 1 = 0.667x 0 - .002. The extraction isotherm i.e. parabola equation came as : x 1 = 0.003y 0 2 + 0.723y 0 considering three points i.e. (0,0), (13,16.7) (uranium analysis for first stage of mixer-settler) and (25, 30.69) (feed concentration, loading capacity of solvent). Using these two equations the results that were obtained, predicted the solute distribution across different stages exactly as it is in the running mixer settler. Individual isotherms could also be drawn with the predicted results from the

  12. Calculation Of Extraction Optics For Ion System With Plazma Emitter

    CERN Document Server

    Frolov, B A

    2004-01-01

    The 2-D code for simulating of ion optics system of positive ion extraction from a plasma source is described. Example calculation of 100 kV optics for the extraction ion IHEP gun is presented. The trajectories of particles and emittance plots are resulted. The aberrations influ-ence strongly on ion optics for considered geometry.

  13. Electronic simulation of the supported liquid membrane in electromembrane extraction systems: Improvement of the extraction by precise periodical reversing of the field polarity

    International Nuclear Information System (INIS)

    Moazami, Hamid Reza; Nojavan, Saeed; Zahedi, Pegah; Davarani, Saied Saeed Hosseiny

    2014-01-01

    Highlights: • A simple equivalent circuit has been proposed for a supported liquid membrane. • A dual charge transfer mechanism was proposed for electromembrane extraction. • An improvement was observed by precise periodical reversing of the field polarity. - Abstract: In order to understand the limitations of electromebrane extraction procedure better, a simple equivalent circuit has been proposed for a supported liquid membrane consisting of a resistor and a low leakage capacitor in series. To verify the equivalent circuit, it was subjected to a simulated periodical polarity changing potential and the resulting time variation of the current was compared with that of a real electromembrane extraction system. The results showed a good agreement between the simulated current patterns and those of the real ones. In order to investigate the impact of various limiting factors, the corresponding values of the equivalent circuit were estimated for a real electromembrane extraction system and were attributed to the physical parameters of the extraction system. A dual charge transfer mechanism was proposed for electromembrane extraction by combining general migration equation and fundamental aspects derived from the simulation. Dual mechanism comprises a current dependent contribution of analyte in total current and could support the possibility of an improvement in performance of an electromembrane extraction by application of an asymmetric polarity changing potential. The optimization of frequency and duty cycle of the asymmetric polarity exchanging potential resulted in a higher recovery (2.17 times greater) in comparison with the conventional electromebrane extraction. The simulation also provided more quantitative approaches toward the investigation of the mechanism of extraction and contribution of different limiting factors in electromembrane extraction. Results showed that the buildup of the double layer is the main limiting factor and the Joule heating has

  14. Reliability analysis of diverse safety logic systems of fast breeder reactor

    International Nuclear Information System (INIS)

    Ravi Kumar, Bh.; Apte, P.R.; Srivani, L.; Ilango Sambasivan, S.; Swaminathan, P.

    2006-01-01

    Safety Logic for Fast Breeder Reactor (FBR) is designed to initiate safety action against Design Basis Events. Based on the outputs of various processing circuits, Safety logic system drives the control rods of the shutdown system. So, Safety Logic system is classified as safety critical system. Therefore, reliability analysis has to be performed. This paper discusses the Reliability analysis of Diverse Safety logic systems of FBRs. For this literature survey on safety critical systems, system reliability approach and standards to be followed like IEC-61508 are discussed in detail. For Programmable Logic device based systems, Hardware Description Languages (HDL) are used. So this paper also discusses the Verification and Validation for HDLs. Finally a case study for the Reliability analysis of Safety logic is discussed. (author)

  15. Intralaryngeal thyroarytaenoid lateralisation using the Fast-Fix 360 system: a canine cadaveric study.

    Science.gov (United States)

    Stegen, Ludo; Kitshoff, Adriaan M; Van Goethem, Bart; Vandekerckhove, Peter; de Rooster, Hilde

    2015-01-01

    Laryngeal paralysis is a condition in which failure of arytaenoid abduction results in a reduced rima glottidis cross-sectional area. The most commonly performed surgical techniques rely on unilateral abduction of the arytaenoid, requiring a lateral or ventral surgical approach to the larynx. The aim of the study was to investigate a novel minimally invasive intralaryngeal thyroarytaenoid lateralisation technique, using the Fast-Fix 360 meniscal repair system. Larynges were harvested from large breed canine cadavers. With the aid of Kirschner wires placed between the centre of the vocal process and the centre of an imaginary line between the cranial thyroid fissure and the cricothyroid articulation, the mean insertion angle was calculated. The Fast-Fix 360 delivery needle inserted intralaryngeally (n=10), according to a simplified insertion angle (70°), resulted in thyroid penetration (>2.5 mm from margin) in all patients. The Fast-Fix was applied unilaterally at 70° with the first toggle fired on the lateral aspect of the thyroid cartilage and inside the laryngeal cavity on retraction. The suture was tightened. Preprocedural (61.06±9.21 mm2) and postprocedural (138.37±26.12 mm2) rima glottidis cross-sectional area was significantly different (P<0.0001). The mean percentage increase in rima glottidis cross-sectional area was 125.96 per cent (±16.54 per cent). Intralaryngeal thyroarytaenoid laterlisation using the Fast-Fix 360 meniscal repair system ex vivo increased the rima glottidis cross-sectional area significantly.

  16. Autonomous gas chromatograph system for Thermal Enhanced Vapor Extraction System (TEVES) proof of concept demonstration

    International Nuclear Information System (INIS)

    Peter, F.J.; Laguna, G.R.

    1996-09-01

    An autonomous gas chromatograph system was designed and built to support the Thermal Enhanced Vapor Extraction System (TEVES) demonstration. TEVES is a remediation demonstration that seeks to enhance an existing technology (vacuum extraction) by adding a new technology (soil heating). A pilot scale unit was set up at one of the organic waste disposal pits at the Sandia National Laboratories Chemical Waste Landfill (CWL) in Tech Area 3. The responsibility for engineering a major part of the process instrumentation for TEVES belonged to the Manufacturing Control Subsystems Department. The primary mission of the one-of-a-kind hardware/software system is to perform on-site gas sampling and analysis to quantify a variety of volatile organic compounds (VOCs) from various sources during TEVES operations. The secondary mission is to monitor a variety of TEVES process physical parameters such as extraction manifold temperature, pressure, humidity, and flow rate, and various subsurface pressures. The system began operation in September 1994 and was still in use on follow-on projects when this report was published

  17. Extracted-beam-detection system around synchrotron saturne

    International Nuclear Information System (INIS)

    Anne, Remy; Milleret, Gerard; Giuliani, Arlette; Lefol, Andre; Perret, Robert; Poupard, Joseph; Trogno, Andre; Van den Bossche, Maurice; N'Guyen Sieu Viet.

    1977-07-01

    The extracted-beam-detection system working around the synchrotron Saturne is presented. The whole system is composed of about forty multiwire chambers used for beam tuning and providing beams profiles. Optic beam parameters such as position, divergence, dimension, emittance can be easily measured, or calculated with a program running on a computer. They are working in large range intensity beams (10 2 to 5.10 11 p/cm 2 /s of protons, alpha particles, deutons, pions, tritons and electrons [fr

  18. ITER Fast Plant System Controller prototype based on PXIe platform

    International Nuclear Information System (INIS)

    Ruiz, M.; Vega, J.; Castro, R.; Sanz, D.; López, J.M.; Arcas, G. de; Barrera, E.; Nieto, J.; Gonçalves, B.; Sousa, J.; Carvalho, B.; Utzel, N.; Makijarvi, P.

    2012-01-01

    Highlights: ► Implementation of Fast Plant System Controller (FPSC) for ITER CODAC. ► Efficient data acquisition and data movement using EPICS. ► Performance of PCIe technologies in the implementation of FPSC. - Abstract: The ITER Fast Plant System Controller (FPSC) is based on embedded technologies. The FPSC will be devoted to both data acquisition tasks (sampling rates higher than 1 kHz) and control purposes (feedback loop actuators). Some of the essential requirements of these systems are: (a) data acquisition and data preprocessing; (b) interfacing with different networks and high speed links (Plant Operation Network, timing network based on IEEE1588, synchronous data transference and streaming/archiving networks); and (c) system setup and operation using EPICS (Experimental Physics and Industrial Control System) process variables. CIEMAT and UPM have implemented a prototype of FPSC using a PXIe (PCI eXtension for Instrumentation) form factor in a R and D project developed in two phases. The paper presents the main features of the two prototypes developed that have been named alpha and beta. The former was implemented using LabVIEW development tools as it was focused on modeling the FPSC software modules, using the graphical features of LabVIEW applications, and measuring the basic performance in the system. The alpha version prototype implements data acquisition with time-stamping, EPICS monitoring using waveform process variables (PVs), and archiving. The beta version prototype is a complete IOC implemented using EPICS with different software functional blocks. These functional blocks are integrated and managed using an ASYN driver solution and provide the basic functionalities required by ITER FPSC such as data acquisition, data archiving, data pre-processing (using both CPU and GPU) and streaming.

  19. Automatic extraction of property norm-like data from large text corpora.

    Science.gov (United States)

    Kelly, Colin; Devereux, Barry; Korhonen, Anna

    2014-01-01

    Traditional methods for deriving property-based representations of concepts from text have focused on either extracting only a subset of possible relation types, such as hyponymy/hypernymy (e.g., car is-a vehicle) or meronymy/metonymy (e.g., car has wheels), or unspecified relations (e.g., car--petrol). We propose a system for the challenging task of automatic, large-scale acquisition of unconstrained, human-like property norms from large text corpora, and discuss the theoretical implications of such a system. We employ syntactic, semantic, and encyclopedic information to guide our extraction, yielding concept-relation-feature triples (e.g., car be fast, car require petrol, car cause pollution), which approximate property-based conceptual representations. Our novel method extracts candidate triples from parsed corpora (Wikipedia and the British National Corpus) using syntactically and grammatically motivated rules, then reweights triples with a linear combination of their frequency and four statistical metrics. We assess our system output in three ways: lexical comparison with norms derived from human-generated property norm data, direct evaluation by four human judges, and a semantic distance comparison with both WordNet similarity data and human-judged concept similarity ratings. Our system offers a viable and performant method of plausible triple extraction: Our lexical comparison shows comparable performance to the current state-of-the-art, while subsequent evaluations exhibit the human-like character of our generated properties.

  20. Development and operation of fast protection for KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jaesic, E-mail: hjaesic@nfri.re.kr; Lee, Woongryol; Lee, Taegu; Han, Hyunsun; Han, Sang-Hee; Park, Kaprai

    2016-11-15

    Highlights: • The evolution of KSTAR machine interlock system. • The evolution of KSTAR fast interlock. • The fast interlock interface. • The operation results of the fast interlock. - Abstract: Protection for the Korea superconducting tokamak advanced research (KSTAR) is somewhat more complicated than for the previous tokomak generation. External reasons for this increased complexity are the initial and maintenance costs, and internal reasons relate to various characteristics of the tokamak and long pulse operation. KSTAR has two protection mechanisms: the device protection system protects damage to superconducting coils etc. from events within the other systems, and the fast protection system protects the internal vacuum vessel components against damage from heating and the long pulse plasma. The fast protection system initially contained the plasma control system (PCS), central control system (CCS), and the heating devices. In 2012, a fast interlock interface was implemented for PCS fail-safe. This detected the absence of plasma current using the diagnostic signals and discharge operation gate windows of the timing synchronized system (TSS), and activates the operation gates and heating stop from the CCS. Additional fast interlock logic was implemented to reduce damage to the plasma facing components (PFC) and other materials by overheating and improper operational state of heating systems after starting the discharge sequence. However, the fast interlock interface system has failed to protect the heating during PCS malfunctions since 2013. This paper introduces the KSTAR protection system, and describes the fast protection interface, with testing and operational results, then discusses future plans for a more effective and safer protection system.

  1. Effect of Potent Ethyl Acetate Fraction of Stereospermum suaveolens Extract in Streptozotocin-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    T. Balasubramanian

    2012-01-01

    Full Text Available To evaluate the antihyperglycemic effect of ethyl acetate fraction of ethanol extract of Stereospermum suaveolens in streptozotocin-(STZ- induced diabetic rats by acute and subacute models. In this paper, various fractions of ethanol extract of Stereospermum suaveolens were prepared and their effects on blood glucose levels in STZ-induced diabetic rats were studied after a single oral administration (200?mg/kg. Administration of the ethyl acetate fraction at 200?mg/kg once daily for 14 days to STZ-induced diabetic rats was also carried out. The parameters such as the fasting blood glucose, hepatic glycogen content, and pancreatic antioxidant levels were monitored. In the acute study, the ethyl acetate fraction is the most potent in reducing the fasting serum glucose levels of the STZ-induced diabetic rats. The 14-day repeated oral administration of the ethyl acetate fraction significantly reduced the fasting blood glucose and pancreatic TBARS level and significantly increased the liver glycogen, pancreatic superoxide dismutase, and catalase activities as well as reduced glutathione levels. The histopathological studies during the subacute treatment have been shown to ameliorate the STZ-induced histological damage of pancreas. This paper concludes that the ethyl acetate fraction from ethanol extract of Stereospermum suaveolens possesses potent antihyperglycemic and antioxidant properties, thereby substantiating the use of plant in the indigenous system of medicine.

  2. RF-knockout Extraction System for the CNAO Synchrotron

    CERN Document Server

    Carmignani, Nicola; Serio, Mario; Balbinot, Giovanni; Bressi, Erminia; Caldara, Michele; Pullia, Marco; Bosser, Jacques; Venchi, Giuseppe

    2010-01-01

    The National Centre for Oncological Hadrontherapy (CNAO) is a centre in Italy for the treatment of patients affected by tumours with proton and carbon ions beams accelerated in a synchrotron. The synchrotron extraction method is based on the use of a betatron core. This work aims to verify, through a theoretical study and a simulation, the possibility of using the RF-knockout extraction method exploiting the existing hardware. A simulation program has been written to simulate the extraction system of the synchrotron with the purpose to define the parameters of the radio frequency. Two types of radio frequencies have been compared in order to obtain a constant spill with the minimum ripple: a carrier wave with a frequency and amplitude modulation, and a gaussian narrow band noise modulated in amplitude. Results of the simulation and considerations on the kicker characteristics are presented

  3. The extraction behaviour of As(III) and As(V) in APDC-CCl4 system

    International Nuclear Information System (INIS)

    Yang Ruiying; Zhu Xuping

    1997-01-01

    The extraction and back-extraction behaviour of As(III) and As(V) in APDC-CCl 4 system have been studied by using 76 As trace technique. As(III) can be extracted quantitatively by APDC-CCl 4 system at pH = 1-3. As(V) can be extracted after being reduced to As(III) by Na 2 S 2 O 3 . Water with high pH value can be used for back-extraction. The method can be applied in the separation of inorganic As(III) and As(V) in water quality inspection

  4. Calibration Measurements of the LHC Beam Dumping System Extraction Kicker Magnets

    CERN Document Server

    Uythoven, J; Ducimetière, L; Goddard, B; Gräwer, G; Olivieri, F; Pereira, L; Vossenberg, Eugène B

    2006-01-01

    The LHC beam dumping system must protect the LHC machine from damage by reliably and safely extracting and absorbing the circulating beams when requested. Two sets of 15 extraction kicker magnets form the main active part of this system. They have been produced, tested and calibrated by measuring the integrated magnetic field and the magnet current at different beam energies. The calibration data have been analysed, and the critical parameters are compared with the specifications. Implications for the configuration, control and operation of the beam dumping system are discussed.

  5. Numerical Study of Quench Protection for Fast-Ramping Accelerator Magnets

    CERN Document Server

    Schwerg, N; Mess, K-N; Russenschuck, S

    2009-01-01

    The quench module of the ROXIE field computation program has been presented at previous conferences. In this paper we discuss recently implemented features that allow quench simulation of fast-ramping superconducting magnets. As the reliability of quench detection during the ramps depends on the signal to noise ratio, we simulate the influence of detection thresholds and the propagation of undetected quenches during the ramps. We also study the effect of an increased copper content and the feasibility of a self-protected magnet surviving a powering cycle with an undetected quench and without quench heater firing or energy-extraction system.

  6. A fast and optimized dynamic economic load dispatch for large scale power systems

    International Nuclear Information System (INIS)

    Musse Mohamud Ahmed; Mohd Ruddin Ab Ghani; Ismail Hassan

    2000-01-01

    This paper presents Lagrangian Multipliers (LM) and Linear Programming (LP) based dynamic economic load dispatch (DELD) solution for large-scale power system operations. It is to minimize the operation cost of power generation. units subject to the considered constraints. After individual generator units are economically loaded and periodically dispatched, fast and optimized DELD has been achieved. DELD with period intervals has been taken into consideration The results found from the algorithm based on LM and LP techniques appear to be modest in both optimizing the operation cost and achieving fast computation. (author)

  7. Conceptual design of the fast ignition laser fusion power plant (KOYO-Fast). 6. Design of chamber and reactor system

    International Nuclear Information System (INIS)

    Kozaki, Yasuji; Norimatsu, Takayoshi; Furukawa, Hiroyuki; Hayashi, Takumi; Souman, Yoshihito; Nishikawa, Masabumi; Tomabechi, Ken

    2007-01-01

    A conceptual design of the reactor chamber system with LiPb liquid wall based on the fast ignition cone target design and the related reactor systems with exhaust system, laser beam shutter, blanket and cooling system are summarized. The multi overflow fall method was investigated as the structure of chamber and repeating 4 Hz pulse potential. The ablation depth of LiPb liquid wall was estimated and the conditions of repeat of operation were evaluated. The basic design of chamber, selection and conditions of liquid wall chamber, recycle type multi overflow fall (MOF) wall, LiPb two layers blanket structure, basic specification of reactor system, laser beam line shutter, design of chamber exhaust system, cooling system, tritium recovery system, power plant total design and arrangement of chamber and laser beam, and issues are stated. (S.Y.)

  8. State space model extraction of thermohydraulic systems – Part I: A linear graph approach

    International Nuclear Information System (INIS)

    Uren, K.R.; Schoor, G. van

    2013-01-01

    Thermohydraulic simulation codes are increasingly making use of graphical design interfaces. The user can quickly and easily design a thermohydraulic system by placing symbols on the screen resembling system components. These components can then be connected to form a system representation. Such system models may then be used to obtain detailed simulations of the physical system. Usually this kind of simulation models are too complex and not ideal for control system design. Therefore, a need exists for automated techniques to extract lumped parameter models useful for control system design. The goal of this first paper, in a two part series, is to propose a method that utilises a graphical representation of a thermohydraulic system, and a lumped parameter modelling approach, to extract state space models. In this methodology each physical domain of the thermohydraulic system is represented by a linear graph. These linear graphs capture the interaction between all components within and across energy domains – hydraulic, thermal and mechanical. These linear graphs are analysed using a graph-theoretic approach to derive reduced order state space models. These models capture the dominant dynamics of the thermohydraulic system and are ideal for control system design purposes. The proposed state space model extraction method is demonstrated by considering a U-tube system. A non-linear state space model is extracted representing both the hydraulic and thermal domain dynamics of the system. The simulated state space model is compared with a Flownex ® model of the U-tube. Flownex ® is a validated systems thermal-fluid simulation software package. - Highlights: • A state space model extraction methodology based on graph-theoretic concepts. • An energy-based approach to consider multi-domain systems in a common framework. • Allow extraction of transparent (white-box) state space models automatically. • Reduced order models containing only independent state

  9. Fast reactors: potential for power

    International Nuclear Information System (INIS)

    1983-02-01

    The subject is discussed as follows: basic facts about conventional and fast reactors; uranium economy; plutonium and fast reactors; cooling systems; sodium coolant; safety engineering; handling and recycling plutonium; safeguards; development of fast reactors in Britain and abroad; future progress. (U.K.)

  10. COMPARATIVE STUDY OF THREE LINEAR SYSTEM SOLVER APPLIED TO FAST DECOUPLED LOAD FLOW METHOD FOR CONTINGENCY ANALYSIS

    Directory of Open Access Journals (Sweden)

    Syafii

    2017-03-01

    Full Text Available This paper presents the assessment of fast decoupled load flow computation using three linear system solver scheme. The full matrix version of the fast decoupled load flow based on XB methods used in this study. The numerical investigations are carried out on the small and large test systems. The execution time of small system such as IEEE 14, 30, and 57 are very fast, therefore the computation time can not be compared for these cases. Another cases IEEE 118, 300 and TNB 664 produced significant execution speedup. The superLU factorization sparse matrix solver has best performance and speedup of load flow solution as well as in contigency analysis. The invers full matrix solver can solved only for IEEE 118 bus test system in 3.715 second and for another cases take too long time. However for superLU factorization linear solver can solved all of test system in 7.832 second for a largest of test system. Therefore the superLU factorization linear solver can be a viable alternative applied in contingency analysis.

  11. Plutonium Worlds. Fast Breeders, Systems Analysis and Computer Simulation in the Age of Hypotheticality

    Directory of Open Access Journals (Sweden)

    Sebastian Vehlken

    2014-09-01

    Full Text Available This article examines the media history of one of the hallmark civil nuclear energy programs in Western Germany – the development of Liquid Metal Fast Breeder Reactor (LMFBR technology. Promoted as a kind of perpetuum mobile of the Atomic Age, the "German Manhattan Project" not only imported big science thinking. In its context, nuclear technology was also put forth as an avantgarde of scientific inquiry, dealing with the most complex and critical technological endeavors. In the face of the risks of nuclear technology, German physicist Wolf Häfele thus announced a novel epistemology of "hypotheticality". In a context where traditional experimental engineering strategies became inappropiate, he called for the application of advanced media technologies: Computer Simulations (CS and Systems Analysis (SA generated computerized spaces for the production of knowledge. In the course of the German Fast Breeder program, such methods had a twofold impact. One the one hand, Häfele emphazised – as the "father of the German Fast Breeder" – the utilization of CS for the actual planning and construction of the novel reactor type. On the other, namely as the director of the department of Energy Systems at the International Institute for Applied Systems Analysis (IIASA, Häfele advised SA-based projections of energy consumption. These computerized scenarios provided the rationale for the conception of Fast Breeder programs as viable and necessary alternative energy sources in the first place. By focusing on the role of the involved CS techniques, the paper thus investigates the intertwined systems thinking of nuclear facilities’s planning and construction and the design of large-scale energy consumption and production scenarios in the 1970s and 1980s, as well as their conceptual afterlives in our contemporary era of computer simulation.

  12. Passive safety system of a super fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sutanto, E-mail: sutanto@fuji.waseda.jp [Cooperative Major in Nuclear Energy, Waseda University, Tokyo (Japan); Polytechnic Institute of Nuclear Technology—National Nuclear Energy Agency, Yogyakarta (Indonesia); Oka, Yoshiaki [The University of Tokyo, Tokyo (Japan)

    2015-08-15

    Highlights: • Passive safety system of a Super FR is proposed. • Total loss of feedwater flow and large LOCA are analyzed. • The criteria of MCST and core pressure are satisfied. - Abstract: Passive safety systems of a Super Fast Reactor are studied. The passive safety systems consist of isolation condenser (IC), automatic depressurization system (ADS), core make-up tank (CMT), gravity driven cooling system (GDCS), and passive containment cooling system (PCCS). Two accidents of total loss of feedwater flow and 100% cold-leg break large LOCA are analyzed by using the passive systems and the criteria of maximum cladding surface temperature (MCST) and maximum core pressure are satisfied. The isolation condenser can be used for mitigation of the accident of total loss of feedwater flow at both supercritical and subcritical pressures. The ADS is used for depressurization leading to a loss of coolant during line switching to operation of the isolation condenser at subcritical pressure. Use of CMT during line switching recovers the lost coolant. In case of large LOCA, GDCS can be used for core reflooding. Coolant vaporization in the core released to containment through the break is condensed by passive containment cooling system. The condensate flows to the GDCS pool by gravity force. The maximum cladding surface temperature (MCST) of the accident satisfies the criterion.

  13. Ion extraction capabilities of two-grid accelerator systems

    International Nuclear Information System (INIS)

    Rovang, D.C.; Wilbur, P.J.

    1984-02-01

    An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. This work resulted in a large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high. The apparatus developed for this study is also shown to be well suited measuring the electron backstreaming and electrical breakdown characteristics of two-grid accelerator systems

  14. FAST Modularization Framework for Wind Turbine Simulation: Full-System Linearization: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jonkman, Jason; Jonkman, Bonnie

    2016-11-01

    The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations e.g. for design-standards-based loads analysis. Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system response and exploit well-established methods and tools for analyzing linear systems. This paper presents the development and verification of the new linearization functionality of the open-source engineering tool FAST v8 for land-based wind turbines, as well as the concepts and mathematical background needed to understand and apply it correctly.

  15. Demonstration of the Cascadia G‐FAST geodetic earthquake early warning system for the Nisqually, Washington, earthquake

    Science.gov (United States)

    Crowell, Brendan; Schmidt, David; Bodin, Paul; Vidale, John; Gomberg, Joan S.; Hartog, Renate; Kress, Victor; Melbourne, Tim; Santillian, Marcelo; Minson, Sarah E.; Jamison, Dylan

    2016-01-01

    A prototype earthquake early warning (EEW) system is currently in development in the Pacific Northwest. We have taken a two‐stage approach to EEW: (1) detection and initial characterization using strong‐motion data with the Earthquake Alarm Systems (ElarmS) seismic early warning package and (2) the triggering of geodetic modeling modules using Global Navigation Satellite Systems data that help provide robust estimates of large‐magnitude earthquakes. In this article we demonstrate the performance of the latter, the Geodetic First Approximation of Size and Time (G‐FAST) geodetic early warning system, using simulated displacements for the 2001Mw 6.8 Nisqually earthquake. We test the timing and performance of the two G‐FAST source characterization modules, peak ground displacement scaling, and Centroid Moment Tensor‐driven finite‐fault‐slip modeling under ideal, latent, noisy, and incomplete data conditions. We show good agreement between source parameters computed by G‐FAST with previously published and postprocessed seismic and geodetic results for all test cases and modeling modules, and we discuss the challenges with integration into the U.S. Geological Survey’s ShakeAlert EEW system.

  16. A fast and versatile quantum key distribution system with hardware key distillation and wavelength multiplexing

    International Nuclear Information System (INIS)

    Walenta, N; Gisin, N; Guinnard, O; Houlmann, R; Korzh, B; Lim, C W; Lunghi, T; Portmann, C; Thew, R T; Burg, A; Constantin, J; Caselunghe, D; Kulesza, N; Legré, M; Monat, L; Soucarros, M; Trinkler, P; Junod, P; Trolliet, G; Vannel, F

    2014-01-01

    We present a compactly integrated, 625 MHz clocked coherent one-way quantum key distribution system which continuously distributes secret keys over an optical fibre link. To support high secret key rates, we implemented a fast hardware key distillation engine which allows for key distillation rates up to 4 Mbps in real time. The system employs wavelength multiplexing in order to run over only a single optical fibre. Using fast gated InGaAs single photon detectors, we reliably distribute secret keys with a rate above 21 kbps over 25 km of optical fibre. We optimized the system considering a security analysis that respects finite-key-size effects, authentication costs and system errors for a security parameter of ε QKD  = 4 × 10 −9 . (paper)

  17. Extraction of iron(III) with diphenyl-2-pyridylmethane dissolved in benzene from aqueous chloride solutions

    International Nuclear Information System (INIS)

    Suhail Ahmed; Shamas-Ud-Zuha; Abdul Ghafoor; Ejaz, M.

    1978-01-01

    The mechanism of extraction has been investigated by partition, slope analysis and loading-ratio data. The results obtained give a picture of the mechanism of extraction of FeCl 4 - ions in relation to the hydration and solvation of the compound extracted. The possible formula of the extracted species is (DPPM)sub(3)Hsub(3)Osup(+)(Hsub(2)O)sub(n)-FeClsub(4)sup(-). In dilute aqueous hydrochloric acid systems the influence of the concentration of a number of salts with cations of different electrical potentials (Ze/r), on iron(III) extraction, has been studied. Splitting of the organic phases occurs at high acid and/or high salt concentrations. The phenomenon is explained on the basis of the variability of the hydration number. Investigations have been made to understand the parameters controlling the extraction of the metal and it is shown that the extraction offers a simple, fast and selective separation method of iron from solutions. (author)

  18. VoxHenry: FFT-Accelerated Inductance Extraction for Voxelized Geometries

    KAUST Repository

    Yucel, Abdulkadir C.

    2018-01-18

    VoxHenry, a fast Fourier transform (FFT)-accelerated integral-equation-based simulator for extracting frequency-dependent inductances and resistances of structures discretized by voxels, is presented. VoxHenry shares many features with the popular inductance extractor, FastHenry. Just like FastHenry, VoxHenry solves a combination of the electric volume integral equation and the current continuity equation, but with three distinctions that make VoxHenry suitable and extremely efficient for analyzing voxelized geometries: 1) it leverages a carefully selected set of piecewise-constant and piecewise-linear basis functions; 2) it exploits FFTs to accelerate the matrix-vector multiplications during the iterative solution of system of equations; and 3) it employs a sparse preconditioner to ensure the rapid convergence of iterative solution. VoxHenry is capable of accurately computing frequency-dependent inductances and resistances of arbitrarily shaped and large-scale structures on a desktop computer. The accuracy, efficiency, and applicability of VoxHenry are demonstrated through inductance analysis of various structures, including square and circular coils as well as arrays of RF inductors (situated over ground planes).

  19. The algorithm of fast image stitching based on multi-feature extraction

    Science.gov (United States)

    Yang, Chunde; Wu, Ge; Shi, Jing

    2018-05-01

    This paper proposed an improved image registration method combining Hu-based invariant moment contour information and feature points detection, aiming to solve the problems in traditional image stitching algorithm, such as time-consuming feature points extraction process, redundant invalid information overload and inefficiency. First, use the neighborhood of pixels to extract the contour information, employing the Hu invariant moment as similarity measure to extract SIFT feature points in those similar regions. Then replace the Euclidean distance with Hellinger kernel function to improve the initial matching efficiency and get less mismatching points, further, estimate affine transformation matrix between the images. Finally, local color mapping method is adopted to solve uneven exposure, using the improved multiresolution fusion algorithm to fuse the mosaic images and realize seamless stitching. Experimental results confirm high accuracy and efficiency of method proposed in this paper.

  20. Reprint of: Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    International Nuclear Information System (INIS)

    Zarzycki, Paweł K.; Ślączka, Magdalena M.; Zarzycka, Magdalena B.; Włodarczyk, Elżbieta; Baran, Michał J.

    2012-01-01

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds’ feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5–8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  1. Reprint of: Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Zarzycki, Pawel K., E-mail: pawel_k_z@hotmail.com [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland); Slaczka, Magdalena M.; Zarzycka, Magdalena B.; Wlodarczyk, Elzbieta; Baran, Michal J. [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland)

    2012-02-24

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds' feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5-8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  2. Feature Extraction Using Fractal Codes

    NARCIS (Netherlands)

    B.A.M. Schouten (Ben); P.M. de Zeeuw (Paul)

    1999-01-01

    htmlabstractFast and successful searching for an object in a multimedia database is a highly desirable functionality. Several approaches to content based retrieval for multimedia databases can be found in the literature [9,10,12,14,17]. The approach we consider is feature extraction. A feature can

  3. Implementation and Performance of FPGA based track fitting for the Atlas Fast TracKer

    CERN Document Server

    Zou, Rui; The ATLAS collaboration

    2018-01-01

    The Fast TracKer (FTK) within the ATLAS trigger system provides global track reconstruction for all events passing the ATLAS Level 1 trigger by dividing the detector into parallel processing pipelines that implement pattern matching in custom integrated circuits and data routing, reduction, and parameter extraction in FPGAs. In this presentation we will describe the implementation of a critical component of the system which does partial track fitting using a method based on a principal component analysis at a rate of greater than 1 fit per 10 ps, system-wide, to reduce the output of the pattern matching. Firmware design, timing performance and preliminary results will be discussed.

  4. Low-parachor solvents extraction and thermostated micro-thin-layer chromatography separation for fast screening and classification of spirulina from pharmaceutical formulations and food samples.

    Science.gov (United States)

    Zarzycki, Paweł K; Zarzycka, Magdalena B; Clifton, Vicki L; Adamski, Jerzy; Głód, Bronisław K

    2011-08-19

    The goal of this paper is to demonstrate the separation and detection capability of eco-friendly micro-TLC technique for the classification of spirulina and selected herbs from pharmaceutical and food products. Target compounds were extracted using relatively low-parachor liquids. A number of the spirulina samples which originated from pharmaceutical formulations and food products, were isolated using a simple one step extraction with small volume of methanol, acetone or tetrahydrofuran. Herb samples rich in chlorophyll dyes were analyzed as reference materials. Quantitative data derived from micro-plates under visible light conditions and after iodine staining were explored using chemometrics tools including cluster analysis and principal components analysis. Using this method we could easily distinguish genuine spirulina and non-spirulina samples as well as fresh from expired commercial products and furthermore, we could identify some biodegradation peaks appearing on micro-TLC profiles. This methodology can be applied as a fast screening or fingerprinting tool for the classification of genuine spirulina and herb samples and in particular may be used commercially for the rapid quality control screening of products. Furthermore, this approach allows low-cost fractionation of target substances including cyanobacteria pigments in raw biological or environmental samples for preliminary chemotaxonomic investigations. Due to the low consumption of the mobile phase (usually less than 1 mL per run), this method can be considered as environmentally friendly analytical tool, which may be an alternative for fingerprinting protocols based on HPLC machines and simple separation systems involving planar micro-fluidic or micro-chip devices. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Nuclear instrumentation systems in prototype fast breeder reactor

    International Nuclear Information System (INIS)

    Vijayakumaran, P.M.; Nagaraj, C.P.; Paramasivan-Pillai, C.; Ramakrishnan, R.; Sivaramakrishna, M.

    2004-01-01

    The nuclear instrumentation systems of the Prototype Fast Breeder Reactor (PFBR) primarily comprise of global Neutron Flux Monitoring, Failed Fuel Detection and Location, Radiation Monitoring and Post-Accident Monitoring. High temperature fission chambers are provided at in-vessel locations for monitoring neutron flux. Failed fuel detection and location is by monitoring the cover gas for fission gases and primary sodium for delayed neutrons. Signals of the core monitoring detectors are used to initiate SCRAM (safety action) to protect the reactor from various postulated initiating events. Radiation levels in all potentially radioactive areas are monitored to act as an early warning system to keep the release of radioactivity to the environment and exposure to personnel well below the permissible limits. Fission Chambers and Gamma Ionisation Chambers are located in the reactor vault concrete for monitoring the neutron flux and gamma radiation levels during and after an accident. (authors)

  6. Central nervous system activity of Illicium verum fruit extracts.

    Science.gov (United States)

    Chouksey, Divya; Upmanyu, Neeraj; Pawar, R S

    2013-11-01

    To research the acute toxicity of Illicium verum (I. verum) fruit extracts and its action on central nervous system. The TLC and HPTLC techniques were used as fingerprints to determine the chemical components present in I. verum. Male albino rats and mice were utilized for study. The powdered material was successively extracted with n-hexane, ethyl acetate and methanol using a Soxhlet extractor. Acute toxicity studies were performed as per OECD guidelines. The CNS activity was evaluated on parameters of general behavior, sleeping pattern, locomotor activity, anxiety and myocoordination activity. The animals were trained for seven days prior to experiments and the divided into five groups with six animals in each. The drug was administered by intraperitoneal route according to body weight. The dosing was done as prescribed in each protocol. Toxicity studies reported 2 000 mg/kg as toxicological dose and 1/10 of the same dose was taken as therapeutic dose Intraperitoneal injection of all extracts at dose of 200 mg prolonged phenobarbitone induced sleeping time, produced alteration in general behavior pattern, reduced locomotor activity and produced anxiolytic effects but the extracts do not significantly alter muscles coordination activity. The three extracts of I. verum at the dose of 200 mg, methanol extract was found to produce more prominent effects, then hexane and ethylacetate extracts. The observation suggested that the extracts of I. verum possess potent CNS depressant action and anxiolytic effect without interfering with motor coordination. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  7. Activity test of various mangosteen (Garcinia mangostana pericarp extract fractions to decrease fasting blood cholesterol levels and lipid peroxidation activity in diabetic mice

    Directory of Open Access Journals (Sweden)

    Saikhu Akhmad Husen

    2017-01-01

    Full Text Available The objectives of this study were to determine the effect of various fractions of mangosteen (Garcinia mangostana pericarp extract to the changes of the fasting blood cholesterol and serum malondialdehyde (MDA levels on diabetic mice (Mus musculus. Thirty 3-4 months old male mice strain BALB/c, weight 20-30 g were divided into six groups. The first group was KN as a non diabetic control group, KD as a diabetic control, KM as a group of diabetic mice treated with metformin, and NP, SP, and P as the treatment groups that were treated by using three different fractions from mangosteen pericarp extract, non polar, semi polar, and polar respectively. The induction of Diabetes mellitus was done by the injection of STZ, and the mice were given a high fat diet treatment to induce the hiperlipidemia condition using lard for three weeks. The blood cholesterol levels were measured in all groups before and after the injection of lard, and day 1, 7, and 14 of treatment as well. The serum MDA level as the indicator of lipid peroxidation were measured by using QuantiChrom TBARS Assay Kit (DTBA-100. The data of cholesterol levels were statistically analyzed by t-test, while the data of serum MDA levels were analyzed by variance analysis followed by Duncan test. The results showed that the polar fraction of mangosteen pericarp had effect to decrease the fasting blood cholesterol level in mice, however the non polar and semi polar fraction had no simmilar effect. All of the fractions has shown significant effect to decrease the serum MDA level in mice. Key words: cholesterol, diabetes mellitus, Garcinia mangostana, malondialdehyde (mda, obesity.

  8. A fast continuous magnetic field measurement system based on digital signal processors

    International Nuclear Information System (INIS)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; Maroussov, V.; Nehring, R.; Nogiec, J.; Orris, D.; Poukhov, O.; Prakoshyn, F.; Schlabach, P.; Tompkins, J.C.

    2005-01-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements

  9. Feasibility study on commercialization of fast breeder reactor cycle systems interim report of phase II. Technical study report for nuclear fuel cycle systems

    International Nuclear Information System (INIS)

    Sato, Koji; Amamoto, Ippei; Inoue, Akira

    2004-06-01

    As a part of the feasibility study on commercialization of fast breeder reactor cycle systems, the plant concept concerning the fuel cycle systems (combination of the reprocessing and the fuel fabrication) has been constructed to reduce their total cost by the introduction of various innovative techniques and to apply their utmost superior efficiency from such standpoints of a decrease in the environmental burden, better resource utilization and proliferation resistance improvement by the low decontamination transuranium element (TRU) recycle. This interim report of Phase II describes the results of an on-going study which will cover a five-year period. For oxide fuels, the system which combines the use of the advanced aqueous reprocessing using three main methods such as the crystallization method, the simplified solvent extraction method, and the extraction chromatography method for minor actinide (MA) recovery, as well as the simplified pelletizing fuel fabrication which rationalized a powder mixing process etc., has abundant current results and a high technical feasibility for the basic process. Though this system faces difficulties in the technical development of control technology of the extraction chromatography and the fabrication technology of low decontamination TRU fuel etc., its expected practical use is possible at an early stage. As for the super-critical direct extraction reprocessing, it is necessary to fulfill more basic data although further economical improvement of an advanced aqueous reprocessing is expected. The system which combines the advanced aqueous reprocessing and the gelation sphere packing fuel fabrication has the advantage of lesser dispersion of the fine powder due to the use of solution and granule in the fuel fabrication process. However, this system will shoulder additional cost for the reagent recovery process and the waste liquid treatment process due to need to dispose of a large bulk of process waste liquid. The system which

  10. A predator-2 prey fast-slow dynamical system for rapid predator evolution

    DEFF Research Database (Denmark)

    Piltz, Sofia Helena; Veerman, Frits; Maini, Philip K.

    2017-01-01

    We consider adaptive change of diet of a predator population that switches its feeding between two prey populations. We develop a novel 1 fast-3 slow dynamical system to describe the dynamics of the three populations amidst continuous but rapid evolution of the predator's diet choice. The two ext...

  11. Extraction of antioxidants from spruce (Picea abies) bark using eco-friendly solvents.

    Science.gov (United States)

    Co, Michelle; Fagerlund, Amelie; Engman, Lars; Sunnerheim, Kerstin; Sjöberg, Per J R; Turner, Charlotta

    2012-01-01

    Antioxidants are known to avert oxidation processes and they are found in trees and other plant materials. Tree bark is a major waste product from paper pulp industries; hence it is worthwhile to develop an extraction technique to extract the antioxidants. To develop a fast and environmentally sustainable extraction technique for the extraction of antioxidants from bark of spruce (Picea abies) and also to identify the extracted antioxidants that are abundant in spruce bark. A screening experiment that involved three different techniques was conducted to determine the best technique to extract antioxidants. The antioxidant capacity of the extracts was determined with DPPH (2,2-diphenyl-1-picrylhydrazyl) assay. Pressurised fluid extraction (PFE) turned out to be the best technique and a response surface design was therefore utilised to optimise PFE. Furthermore, NMR and HPLC-DAD-MS/MS were applied to identify the extracted antioxidants. PFE using water and ethanol as solvent at 160 and 180°C, respectively, gave extracts of the highest antioxidant capacity. Stilbene glucosides such as isorhapontin, piceid and astringin were identified in the extracts. The study has shown that PFE is a fast and environmentally sustainable technique, using water and ethanol as solvent for the extraction of antioxidants from spruce bark. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Multivariable PD controller design for fast chaos synchronization of Lur'e systems

    International Nuclear Information System (INIS)

    Wen, Guilin; Wang, Qing-Guo; He, Yong; Ye, Zhen

    2007-01-01

    In this Letter, a strategy for fast master-slave synchronization is proposed for Lur'e systems under PD control based on the free-weighting matrix approach and the S-procedure. The purpose of the derivative action is to improve the closed-loop stability and speed synchronization response. The proposed strategy covers the existing result for the proportional control alone as a special case. This approach is illustrated by the Chua's chaotic circuit system

  13. Fuel cycle facility control system for the Integral Fast Reactor Program

    International Nuclear Information System (INIS)

    Benedict, R.W.; Tate, D.A.

    1993-01-01

    As part of the Integral Fast Reactor (IFR) Fuel Demonstration, a new distributed control system designed, implemented and installed. The Fuel processes are a combination of chemical and machining processes operated remotely. To meet this special requirement, the new control system provides complete sequential logic control motion and positioning control and continuous PID loop control. Also, a centralized computer system provides near-real time nuclear material tracking, product quality control data archiving and a centralized reporting function. The control system was configured to use programmable logic controllers, small logic controllers, personal computers with touch screens, engineering work stations and interconnecting networks. By following a structured software development method the operator interface was standardized. The system has been installed and is presently being tested for operations

  14. The ITER Fast Plant System Controller ATCA prototype Real-Time Software Architecture

    International Nuclear Information System (INIS)

    Carvalho, B.B.; Santos, B.; Carvalho, P.F.; Neto, A.; Boncagni, L.; Batista, A.J.N.; Correia, M.; Sousa, J.; Gonçalves, B.

    2013-01-01

    Highlights: ► High performance ATCA systems for fast control and data acquisition. ► IEEE1588 timing system and synchronization. ► Plasma control algorithms. ► Real-time control software frameworks. ► Targeted for nuclear fusion experiments with long duration discharges. -- Abstract: IPFN is developing a prototype Fast Plant System Controller (FPSC) based in ATCA embedded technologies dedicated to ITER CODAC data acquisition and control tasks in the sub-millisecond range. The main goal is to demonstrate the usability of the ATCA standard and its enhanced specifications for the high speed, very high density parallel data acquisition needs of the most demanding ITER tokamak plasma Instrumentation and Control (I and C) systems. This effort included the in-house development of a new family of high performance ATCA I/O and timing boards. The standard ITER software system CODAC Core System (CCS) v3.1, with the control based in the EPICS system does not cover yet the real-time requirements fulfilled by this hardware, so a new set of software components was developed for this specific platform, attempting to integrate and leverage the new features in CSS, for example the Multithreaded Application Real Time executor (MARTe) software framework, the new Data Archiving Network (DAN) solution, an ATCA IEEE-1588-2008 timing interface, and the Intelligent Platform Management Interface (IPMI) for system monitoring and remote management. This paper presents the overall software architecture for the ATCA FPSC, as well a discussion on the ITER constrains and design choices and finally a detailed description of the software components already developed

  15. The ITER Fast Plant System Controller ATCA prototype Real-Time Software Architecture

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, B.B., E-mail: bernardo@ipfn.ist.utl.pt [Associacao EURATOM/IST Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, P-1049-001 Lisboa (Portugal); Santos, B.; Carvalho, P.F.; Neto, A. [Associacao EURATOM/IST Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, P-1049-001 Lisboa (Portugal); Boncagni, L. [Associazione Euratom-ENEA sulla Fusione, Frascati Research Centre, Division of Fusion Physics, Frascati, Rome (Italy); Batista, A.J.N.; Correia, M.; Sousa, J.; Gonçalves, B. [Associacao EURATOM/IST Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, P-1049-001 Lisboa (Portugal)

    2013-10-15

    Highlights: ► High performance ATCA systems for fast control and data acquisition. ► IEEE1588 timing system and synchronization. ► Plasma control algorithms. ► Real-time control software frameworks. ► Targeted for nuclear fusion experiments with long duration discharges. -- Abstract: IPFN is developing a prototype Fast Plant System Controller (FPSC) based in ATCA embedded technologies dedicated to ITER CODAC data acquisition and control tasks in the sub-millisecond range. The main goal is to demonstrate the usability of the ATCA standard and its enhanced specifications for the high speed, very high density parallel data acquisition needs of the most demanding ITER tokamak plasma Instrumentation and Control (I and C) systems. This effort included the in-house development of a new family of high performance ATCA I/O and timing boards. The standard ITER software system CODAC Core System (CCS) v3.1, with the control based in the EPICS system does not cover yet the real-time requirements fulfilled by this hardware, so a new set of software components was developed for this specific platform, attempting to integrate and leverage the new features in CSS, for example the Multithreaded Application Real Time executor (MARTe) software framework, the new Data Archiving Network (DAN) solution, an ATCA IEEE-1588-2008 timing interface, and the Intelligent Platform Management Interface (IPMI) for system monitoring and remote management. This paper presents the overall software architecture for the ATCA FPSC, as well a discussion on the ITER constrains and design choices and finally a detailed description of the software components already developed.

  16. The validation of forensic DNA extraction systems to utilize soil contaminated biological evidence.

    Science.gov (United States)

    Kasu, Mohaimin; Shires, Karen

    2015-07-01

    The production of full DNA profiles from biological evidence found in soil has a high failure rate due largely to the inhibitory substance humic acid (HA). Abundant in various natural soils, HA co-extracts with DNA during extraction and inhibits DNA profiling by binding to the molecular components of the genotyping assay. To successfully utilize traces of soil contaminated evidence, such as that found at many murder and rape crime scenes in South Africa, a reliable HA removal extraction system would often be selected based on previous validation studies. However, for many standard forensic DNA extraction systems, peer-reviewed publications detailing the efficacy on soil evidence is either lacking or is incomplete. Consequently, these sample types are often not collected or fail to yield suitable DNA material due to the use of unsuitable methodology. The aim of this study was to validate the common forensic DNA collection and extraction systems used in South Africa, namely DNA IQ, FTA elute and Nucleosave for processing blood and saliva contaminated with HA. A forensic appropriate volume of biological evidence was spiked with HA (0, 0.5, 1.5 and 2.5 mg/ml) and processed through each extraction protocol for the evaluation of HA removal using QPCR and STR-genotyping. The DNA IQ magnetic bead system effectively removed HA from highly contaminated blood and saliva, and generated consistently acceptable STR profiles from both artificially spiked samples and crude soil samples. This system is highly recommended for use on soil-contaminated evidence over the cellulose card-based systems currently being preferentially used for DNA sample collection. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Model-based Extracted Water Desalination System for Carbon Sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Gettings, Rachel; Dees, Elizabeth

    2017-03-23

    The focus of this research effort centered around water recovery from high Total Dissolved Solids (TDS) extracted waters (180,000 mg/L) using a combination of water recovery (partial desalination) technologies. The research goals of this project were as follows: 1. Define the scope and test location for pilot-scale implementation of the desalination system, 2.Define a scalable, multi-stage extracted water desalination system that yields clean water, concentrated brine, and, salt from saline brines, and 3. Validate overall system performance with field-sourced water using GE pre-pilot lab facilities. Conventional falling film-mechanical vapor recompression (FF-MVR) technology was established as a baseline desalination process. A quality function deployment (QFD) method was used to compare alternate high TDS desalination technologies to the base case FF-MVR technology, including but not limited to: membrane distillation (MD), forward osmosis (FO), and high pressure reverse osmosis (HPRO). Technoeconomic analysis of high pressure reverse osmosis (HPRO) was performed comparing the following two cases: 1. a hybrid seawater RO (SWRO) plus HPRO system and 2. 2x standard seawater RO system, to achieve the same total pure water recovery rate. Pre-pilot-scale tests were conducted using field production water to validate key process steps for extracted water pretreatment. Approximately 5,000 gallons of field produced water was processed through, microfiltration, ultrafiltration, and steam regenerable sorbent operations. Improvements in membrane materials of construction were considered as necessary next steps to achieving further improvement in element performance at high pressure. Several modifications showed promising results in their ability to withstand close to 5,000 PSI without gross failure.

  18. Fast methods for screening of trichothecenes in fungal cultures using gas chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Thrane, Ulf

    2001-01-01

    The paper presents a fast method for trichothecene profiling and chemotaxonomic studies in species of Fusarium, Stachybotrys, Trichoderma and Memnoniella. Micro scale extracted crude Fusarium extracts were derivatised using pentafluoropropionic anhydride and analysed by gas chromatography...

  19. Manufacture of electrostatic septum for extracting particle beam

    International Nuclear Information System (INIS)

    Tokumoto, Shuichi

    1979-01-01

    In the main ring of National Laboratory for High Energy Physics, fast and slow extractions of accelerated proton beam are carried out by using electrostatic septa. The electrostatic septum is an apparatus to deflect beam by an electrostatic field, basically composed of a couple of parallel plate electrodes installed in a vacuum chamber. The electrostatic septum is required to satisfy the following two conditions: it must be very thin and flat to reduce the loss of extracted beam, and sufficiently high electric field must be generated to deflect beam in a limited length. The structure and manufacture of electrostatic septa are described. The manufacturing is explained by dividing a septum into an anode and a cathode, terminals introducing high voltage, a vacuum chamber, and high voltage circuit. The performance is also described on the experiments for no-beam condition and beam extraction. Beam extraction has been carried out over 1500 hours thus far, the average beam intensity being 1 x 10 12 ppp, and extraction efficiency more than 90%. There have been no serious failure to affect the performance nor metal wire breakage. They have satisfied their purposes, being used for both fast and slow extractions. Presently, lengthening of the electrostatic field region is being planned to increase the length of the septa to 1.5 m per unit. (Wakatsuki, Y.)

  20. Strategic and policy issues raised by the transition from thermal to fast nuclear systems

    International Nuclear Information System (INIS)

    2009-01-01

    The renewed interest in nuclear energy triggered by concerns about global climate change and security of supply, which could lead to substantial growth in nuclear electricity generation, enhances the attractiveness of fast neutron reactors with closed fuel cycles. Moving from the current fleet of thermal neutron reactors to fast neutron systems will require many decades and extensive RD-D efforts. This book identifies and analyses key strategic and policy issues raised by such a transition, aiming at providing guidance to decision makers on the best approaches for implementing transition scenarios. The topics covered in this book will be of interest to government and nuclear industry policy makers as well as to specialists working on nuclear energy system analyses and advanced fuel cycle issues. (author)

  1. The control system for SSRF injection and extraction

    International Nuclear Information System (INIS)

    Yuan Qibing; Gu Ming; Wang Ruiping; Cheng Zhihao; Fan Xuerong; Zhu Haijun

    2007-01-01

    This paper introduces the injection and extraction control system design for SSRF, which is a distributed control system aimed at stability and reliability of the pulse power supplies, PPS (Personnel Protection System) and MPS (Machine Protection System). The hardware environment is mainly based on PLC (Programmable Logic Controller), and ARM (Advanced RISC Machine) is also applied for studying stability of the power supplies. WinCC and EPICS (Experimental Physics and Industrial Control System) have been selected as the platforms of SCADA (Supervisory Control and Data Acquisition). For unifying the interfacing to the control computer, all front-end equipments are connected via Industrial Ethernet. (authors)

  2. Conceptual design for Japan sodium-cooled fast reactor. (1) Current status of system design for JSFR

    International Nuclear Information System (INIS)

    Uto, Nariki; Sakai, Takaaki; Mihara, Takatsugu; Kotake, Shoji; Aoto, Kazumi; Toda, Mikio

    2009-01-01

    Japan Atomic Energy Agency is now conducting 'Fast Reactor Cycle Technology Development (FaCT)' project. In the FaCT project, the system design for JSFR has been carried out along the design categories such as safety design, reactor system, heat transport system, etc., together with research and developments (R and Ds) on innovative technologies to be adopted to JSFR for achieving economic competitiveness, enhanced safety and reliability. This paper describes the system design features of JSFR and a summary of the progresses of the design and R and Ds concerned with a compact reactor vessel, an innovative containment vessel, etc. The approach for the commercialization of fast reactors including discussion on a demonstration reactor for JSFR is also briefly described. (author)

  3. Effect of Piper sarmentosum Extract on the Cardiovascular System of Diabetic Sprague-Dawley Rats: Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Zar Chi Thent

    2012-01-01

    Full Text Available Although Piper sarmentosum (PS is known to possess the antidiabetic properties, its efficacy towards diabetic cardiovascular tissues is still obscured. The present study aimed to observe the electron microscopic changes on the cardiac tissue and proximal aorta of experimental rats treated with PS extract. Thirty-two male Sprague-Dawley rats were divided into four groups: untreated control group (C, PS-treated control group (CTx, untreated diabetic group (D, and PS-treated diabetic group (DTx. Intramuscular injection of streptozotocin (STZ, 50 mg/kg body weight was given to induce diabetes. Following 28 days of diabetes induction, PS extract (0.125 g/kg body weight was administered orally for 28 days. Body weight, fasting blood glucose, and urine glucose levels were measured at 4-week interval. At the end of the study, cardiac tissues and the aorta were viewed under transmission electron microscope (TEM. DTx group showed increase in body weight and decrease in fasting blood glucose and urine glucose level compared to the D group. Under TEM study, DTx group showed lesser ultrastructural degenerative changes in the cardiac tissues and the proximal aorta compared to the D group. The results indicate that PS restores ultrastructural integrity in the diabetic cardiovascular tissues.

  4. Hypoglycaemic activity of ethanolic leaf extract and fractions of ...

    African Journals Online (AJOL)

    Holarrhena floribunda is a common plant that has traditionally been used in Africa to treat many diseases such as fever, dysentery, sterility and diabetes. This study was set out to evaluate the hypoglycaemic properties of ethanolic leaf extract of Holarrhena floribunda and various fractions of this extract in normal fasted and ...

  5. Fast Screening of Antibacterial Compounds from Fusaria

    Directory of Open Access Journals (Sweden)

    Teis Esben Sondergaard

    2016-11-01

    Full Text Available Bio-guided screening is an important method to identify bioactive compounds from fungi. In this study we applied a fast digital time-lapse microscopic method for assessment of the antibacterial properties of secondary metabolites from the fungal genus Fusarium. Here antibacterial effects could be detected for antibiotic Y, aurofusarin, beauvericin, enniatins and fusaric acid after six hours of cultivation. The system was then used in a bio-guided screen of extracts from 14 different Fusarium species, which had been fractionated by HPLC. In this screen, fractions containing the red pigments aurofusarin and bikaverin showed effects against strains of Lactobacillus and Bifidobacterium. The IC50 for aurofusarin against Lactobacillus acidophilus was 8 µM, and against Bifidobacterium breve it was 64 µM. Aurofusarin only showed an effect on probiotic bacteria, leading to the speculation that only health-promoting bacteria with a positive effect in the gut system are affected.

  6. New Software for the Fast Estimation of Population Recombination Rates (FastEPRR in the Genomic Era

    Directory of Open Access Journals (Sweden)

    Feng Gao

    2016-06-01

    Full Text Available Genetic recombination is a very important evolutionary mechanism that mixes parental haplotypes and produces new raw material for organismal evolution. As a result, information on recombination rates is critical for biological research. In this paper, we introduce a new extremely fast open-source software package (FastEPRR that uses machine learning to estimate recombination rate ρ (=4Ner from intraspecific DNA polymorphism data. When ρ>10 and the number of sampled diploid individuals is large enough (≥50, the variance of ρFastEPRR remains slightly smaller than that of ρLDhat. The new estimate ρcomb (calculated by averaging ρFastEPRR and ρLDhat has the smallest variance of all cases. When estimating ρFastEPRR, the finite-site model was employed to analyze cases with a high rate of recurrent mutations, and an additional method is proposed to consider the effect of variable recombination rates within windows. Simulations encompassing a wide range of parameters demonstrate that different evolutionary factors, such as demography and selection, may not increase the false positive rate of recombination hotspots. Overall, accuracy of FastEPRR is similar to the well-known method, LDhat, but requires far less computation time. Genetic maps for each human population (YRI, CEU, and CHB extracted from the 1000 Genomes OMNI data set were obtained in less than 3 d using just a single CPU core. The Pearson Pairwise correlation coefficient between the ρFastEPRR and ρLDhat maps is very high, ranging between 0.929 and 0.987 at a 5-Mb scale. Considering that sample sizes for these kinds of data are increasing dramatically with advances in next-generation sequencing technologies, FastEPRR (freely available at http://www.picb.ac.cn/evolgen/ is expected to become a widely used tool for establishing genetic maps and studying recombination hotspots in the population genomic era.

  7. A Risk Assessment System with Automatic Extraction of Event Types

    Science.gov (United States)

    Capet, Philippe; Delavallade, Thomas; Nakamura, Takuya; Sandor, Agnes; Tarsitano, Cedric; Voyatzi, Stavroula

    In this article we describe the joint effort of experts in linguistics, information extraction and risk assessment to integrate EventSpotter, an automatic event extraction engine, into ADAC, an automated early warning system. By detecting as early as possible weak signals of emerging risks ADAC provides a dynamic synthetic picture of situations involving risk. The ADAC system calculates risk on the basis of fuzzy logic rules operated on a template graph whose leaves are event types. EventSpotter is based on a general purpose natural language dependency parser, XIP, enhanced with domain-specific lexical resources (Lexicon-Grammar). Its role is to automatically feed the leaves with input data.

  8. Interactive and automated systems for nuclear track measurements with applications to fast neutron dosimetry

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; McNeece, J.P.; Preston, C.C.; Ruddy, F.H.

    1983-12-01

    Interactive and automatic track measuring systems have been developed primarily for fast neutron dosimetry in and around reactors. The interactive system is used for proton recoil measurements in nuclear research emulsions and the automatic systems for counting fission fragment tracks in Muscovite mica. The status of these systems, along with illustrative applications, are presented, particularly with regard to their relationship to neutron personnel dosimetry. 16 references, 12 figures

  9. Fluorescent lighting system of modified fast starting system; Sistema de alumbrado fluorescente de arranque rapido modificado

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J [Manufacturera De Reactores, S. A., Mexico, D. F. (Mexico)

    1994-12-31

    This paper puts into perspective the possible energy saving in using hybrid ballasts for the operation of fast starting lamps. It presents in summarized form some fundamentals of the fluorescent lamps operation, as well as the fast starting modified systems. Also the results of field operation are shown, as well as the effects on the useful life of the lamp T12 as well as the T8. [Espanol] Este trabajo pone en perspectiva el ahorro de energia posible, al emplear balastros hibridos para operar lamparas de arranque rapido. Presenta en forma resumida algunos fundamentos de la operacion de lamparas fluorescentes, asi como de los sistemas de arranque rapido modificado. Se muestran tambien resultados de operacion de campo, asi como los efectos sobre la vida util de las lamparas, tanto T12 como T8.

  10. Fluorescent lighting system of modified fast starting system; Sistema de alumbrado fluorescente de arranque rapido modificado

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J. [Manufacturera De Reactores, S. A., Mexico, D. F. (Mexico)

    1993-12-31

    This paper puts into perspective the possible energy saving in using hybrid ballasts for the operation of fast starting lamps. It presents in summarized form some fundamentals of the fluorescent lamps operation, as well as the fast starting modified systems. Also the results of field operation are shown, as well as the effects on the useful life of the lamp T12 as well as the T8. [Espanol] Este trabajo pone en perspectiva el ahorro de energia posible, al emplear balastros hibridos para operar lamparas de arranque rapido. Presenta en forma resumida algunos fundamentos de la operacion de lamparas fluorescentes, asi como de los sistemas de arranque rapido modificado. Se muestran tambien resultados de operacion de campo, asi como los efectos sobre la vida util de las lamparas, tanto T12 como T8.

  11. The Data Extraction Using Distributed Crawler Inside Multi-Agent System

    Directory of Open Access Journals (Sweden)

    Karel Tomala

    2013-01-01

    Full Text Available The paper discusses the use of web crawler technology. We created an application based on standard web crawler. Our application is determined for data extraction. Primarily, the application was designed to extract data using keywords from a social network Twitter. First, we created a standard crawler, which went through a predefined list of URLs and gradually download page content of each of the URLs. Page content was then parsed and important text and metadata were stored in a database. Recently, the application was modified in to the form of the multi-agent system. The system was developed in the C# language, which is used to create web applications and sites etc. Obtained data was evaluated graphically. The system was created within Indect project at the VSB-Technical University of Ostrava.

  12. Feature extraction using fractal codes

    NARCIS (Netherlands)

    B.A.M. Ben Schouten; Paul M. de Zeeuw

    1999-01-01

    Fast and successful searching for an object in a multimedia database is a highly desirable functionality. Several approaches to content based retrieval for multimedia databases can be found in the literature [9,10,12,14,17]. The approach we consider is feature extraction. A feature can be seen as a

  13. Adaptive Hybrid Visual Servo Regulation of Mobile Robots Based on Fast Homography Decomposition

    Directory of Open Access Journals (Sweden)

    Chunfu Wu

    2015-01-01

    Full Text Available For the monocular camera-based mobile robot system, an adaptive hybrid visual servo regulation algorithm which is based on a fast homography decomposition method is proposed to drive the mobile robot to its desired position and orientation, even when object’s imaging depth and camera’s position extrinsic parameters are unknown. Firstly, the homography’s particular properties caused by mobile robot’s 2-DOF motion are taken into account to induce a fast homography decomposition method. Secondly, the homography matrix and the extracted orientation error, incorporated with the desired view’s single feature point, are utilized to form an error vector and its open-loop error function. Finally, Lyapunov-based techniques are exploited to construct an adaptive regulation control law, followed by the experimental verification. The experimental results show that the proposed fast homography decomposition method is not only simple and efficient, but also highly precise. Meanwhile, the designed control law can well enable mobile robot position and orientation regulation despite the lack of depth information and camera’s position extrinsic parameters.

  14. Fast multichannel analyser

    Energy Technology Data Exchange (ETDEWEB)

    Berry, A; Przybylski, M M; Sumner, I [Science Research Council, Daresbury (UK). Daresbury Lab.

    1982-10-01

    A fast multichannel analyser (MCA) capable of sampling at a rate of 10/sup 7/ s/sup -1/ has been developed. The instrument is based on an 8 bit parallel encoding analogue to digital converter (ADC) reading into a fast histogramming random access memory (RAM) system, giving 256 channels of 64 k count capacity. The prototype unit is in CAMAC format.

  15. Neutronics and thermal hydraulics coupling scheme for design improvement of liquid metal fast systems

    International Nuclear Information System (INIS)

    Sanchez-Espinoza, V.H.; Jaeger, W.; Travleev, A.; Monti, L.; Doern, R.

    2009-01-01

    Many advanced reactor concepts are nowadays under investigations within the Generation IV international initiative as well as in European research programs including subcritical and critical fast reactor systems cooled by liquid metal, gas and supercritical water. The Institute of Neutron Physics and Reactor Technology (INR) at the Forschungszentrum Karlsruhe GmbH is involved in different European projects like IP EUROTRANS, ELSY, ESFR. The main goal of these projects is, among others, to assess the technical feasibility of proposed concepts regarding safety, economics and transmutation requirements. In view of increased computer capabilities, improved computational schemes, where the neutronic and the thermal hydraulic solution is iteratively coupled, become practicable. The codes ERANOS2.1 and TRACE are being coupled to analyze fuel assembly or core designs of lead-cooled fast reactors (LFR). The neutronic solution obtained with the coupled system for a LFR fuel assembly was compared with the MCNP5 solution. It was shown that the coupled system is predicting physically sound results. The iterative coupling scheme was realized using Perlscripts and auxiliary Fortran programs to ensure that the mapping between the neutronic and the thermal hydraulic part is consistent. The coupled scheme is very flexible and appropriate for the neutron physical and thermal hydraulic investigation of fuel assemblies and of cores of lead cooled fast reactors. The developed methods and the obtained results will be presented and discussed. (author)

  16. COUPLED SIMULATION OF GAS COOLED FAST REACTOR FUEL ASSEMBLY WITH NESTLE CODE SYSTEM

    Directory of Open Access Journals (Sweden)

    Filip Osusky

    2018-05-01

    Full Text Available The paper is focused on coupled calculation of the Gas Cooled Fast Reactor. The proper modelling of coupled neutronics and thermal-hydraulics is the corner stone for future safety assessment of the control and emergency systems. Nowadays, the system and channel thermal-hydraulic codes are accepted by the national regulatory authorities in European Union for license purposes, therefore the code NESTLE was used for the simulation. The NESTLE code is a coupled multigroup neutron diffusion code with thermal-hydraulic sub-channel code. In the paper, the validation of NESTLE code 5.2.1 installation is presented. The processing of fuel assembly homogeneous parametric cross-section library for NESTLE code simulation is made by the sequence TRITON of SCALE code package system. The simulated case in the NESTLE code is one fuel assembly of GFR2400 concept with reflective boundary condition in radial direction and zero flux boundary condition in axial direction. The results of coupled calculation are presented and are consistent with the GFR2400 study of the GoFastR project.

  17. Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Prevo, P.R.

    1986-09-01

    Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986)

  18. A fast direct method for block triangular Toeplitz-like with tri-diagonal block systems from time-fractional partial differential equations

    Science.gov (United States)

    Ke, Rihuan; Ng, Michael K.; Sun, Hai-Wei

    2015-12-01

    In this paper, we study the block lower triangular Toeplitz-like with tri-diagonal blocks system which arises from the time-fractional partial differential equation. Existing fast numerical solver (e.g., fast approximate inversion method) cannot handle such linear system as the main diagonal blocks are different. The main contribution of this paper is to propose a fast direct method for solving this linear system, and to illustrate that the proposed method is much faster than the classical block forward substitution method for solving this linear system. Our idea is based on the divide-and-conquer strategy and together with the fast Fourier transforms for calculating Toeplitz matrix-vector multiplication. The complexity needs O (MNlog2 ⁡ M) arithmetic operations, where M is the number of blocks (the number of time steps) in the system and N is the size (number of spatial grid points) of each block. Numerical examples from the finite difference discretization of time-fractional partial differential equations are also given to demonstrate the efficiency of the proposed method.

  19. Calculating the Degradation Rate of Individual Proteins Using Xenopus Extract Systems.

    Science.gov (United States)

    McDowell, Gary S; Philpott, Anna

    2018-05-16

    The Xenopus extract system has been used extensively as a simple, quick, and robust method for assessing the stability of proteins against proteasomal degradation. In this protocol, methods are provided for assessing the half-life of in vitro translated radiolabeled proteins using Xenopus egg or embryo extracts. © 2019 Cold Spring Harbor Laboratory Press.

  20. Studies on beam extraction from the 1 GeV proton accumulator ring

    International Nuclear Information System (INIS)

    Goyal, Pradeep Kumar; Sharma, Amalendu; Kumar, Vinit; Ghodke, A.D.

    2015-01-01

    For the proposed Indian Spallation Neutron Source (ISNS), a 1 GeV proton Accumulator Ring (AR) is presently being designed at RRCAT. Two optics configurations of AR, namely FODO and Hybrid lattices are under consideration. Each lattice configuration has four superperiods. In this paper, preliminary studies on beam extraction from AR are presented for both the optics configurations. The extraction system will be accommodated in one of the long dispersion free straight sections. Bunch length of the proton beam in AR is 700 ns, and the revolution time of the bunch in AR is 1 ms. This leaves a gap of ∼300 ns for bunch extraction. The proton bunch will be extracted to Ring to Target Beam Transport (RTBT) line, with the help of fast kicker and septum magnets. In this paper, we present the details of the beam extraction scheme with suitable number of kicker magnets, and find out their optimal location and strength. Estimation of field error tolerances for kicker magnets is also presented. (author)

  1. Fast Aerial Video Stitching

    Directory of Open Access Journals (Sweden)

    Jing Li

    2014-10-01

    Full Text Available The highly efficient and robust stitching of aerial video captured by unmanned aerial vehicles (UAVs is a challenging problem in the field of robot vision. Existing commercial image stitching systems have seen success with offline stitching tasks, but they cannot guarantee high-speed performance when dealing with online aerial video sequences. In this paper, we present a novel system which has an unique ability to stitch high-frame rate aerial video at a speed of 150 frames per second (FPS. In addition, rather than using a high-speed vision platform such as FPGA or CUDA, our system is running on a normal personal computer. To achieve this, after the careful comparison of the existing invariant features, we choose the FAST corner and binary descriptor for efficient feature extraction and representation, and present a spatial and temporal coherent filter to fuse the UAV motion information into the feature matching. The proposed filter can remove the majority of feature correspondence outliers and significantly increase the speed of robust feature matching by up to 20 times. To achieve a balance between robustness and efficiency, a dynamic key frame-based stitching framework is used to reduce the accumulation errors. Extensive experiments on challenging UAV datasets demonstrate that our approach can break through the speed limitation and generate an accurate stitching image for aerial video stitching tasks.

  2. Evaluation of Four Automated Protocols for Extraction of DNA from FTA Cards

    OpenAIRE

    Stangegaard, Michael; Børsting, Claus; Ferrero-Miliani, Laura; Frank-Hansen, Rune; Poulsen, Lena; Hansen, Anders J; Morling, Niels

    2013-01-01

    Extraction of DNA using magnetic bead-based techniques on automated DNA extraction instruments provides a fast, reliable, and reproducible method for DNA extraction from various matrices. Here, we have compared the yield and quality of DNA extracted from FTA cards using four automated extraction protocols on three different instruments. The extraction processes were repeated up to six times with the same pieces of FTA cards. The sample material on the FTA cards was either blood or buccal cell...

  3. Real-Time and Real-Fast Performance of General-Purpose and Real-Time Operating Systems in Multithreaded Physical Simulation of Complex Mechanical Systems

    Directory of Open Access Journals (Sweden)

    Carlos Garre

    2014-01-01

    Full Text Available Physical simulation is a valuable tool in many fields of engineering for the tasks of design, prototyping, and testing. General-purpose operating systems (GPOS are designed for real-fast tasks, such as offline simulation of complex physical models that should finish as soon as possible. Interfacing hardware at a given rate (as in a hardware-in-the-loop test requires instead maximizing time determinism, for which real-time operating systems (RTOS are designed. In this paper, real-fast and real-time performance of RTOS and GPOS are compared when simulating models of high complexity with large time steps. This type of applications is usually present in the automotive industry and requires a good trade-off between real-fast and real-time performance. The performance of an RTOS and a GPOS is compared by running a tire model scalable on the number of degrees-of-freedom and parallel threads. The benchmark shows that the GPOS present better performance in real-fast runs but worse in real-time due to nonexplicit task switches and to the latency associated with interprocess communication (IPC and task switch.

  4. Arrhythmia Classification Based on Multi-Domain Feature Extraction for an ECG Recognition System

    Directory of Open Access Journals (Sweden)

    Hongqiang Li

    2016-10-01

    Full Text Available Automatic recognition of arrhythmias is particularly important in the diagnosis of heart diseases. This study presents an electrocardiogram (ECG recognition system based on multi-domain feature extraction to classify ECG beats. An improved wavelet threshold method for ECG signal pre-processing is applied to remove noise interference. A novel multi-domain feature extraction method is proposed; this method employs kernel-independent component analysis in nonlinear feature extraction and uses discrete wavelet transform to extract frequency domain features. The proposed system utilises a support vector machine classifier optimized with a genetic algorithm to recognize different types of heartbeats. An ECG acquisition experimental platform, in which ECG beats are collected as ECG data for classification, is constructed to demonstrate the effectiveness of the system in ECG beat classification. The presented system, when applied to the MIT-BIH arrhythmia database, achieves a high classification accuracy of 98.8%. Experimental results based on the ECG acquisition experimental platform show that the system obtains a satisfactory classification accuracy of 97.3% and is able to classify ECG beats efficiently for the automatic identification of cardiac arrhythmias.

  5. Code system for fast reactor neutronics analysis

    International Nuclear Information System (INIS)

    Nakagawa, Masayuki; Abe, Junji; Sato, Wakaei.

    1983-04-01

    A code system for analysis of fast reactor neutronics has been developed for the purpose of handy use and error reduction. The JOINT code produces the input data file to be used in the neutronics calculation code and also prepares the cross section library file with an assigned format. The effective cross sections are saved in the PDS file with an unified format. At the present stage, this code system includes the following codes; SLAROM, ESELEM5, EXPANDA-G for the production of effective cross sections and CITATION-FBR, ANISN-JR, TWOTRAN2, PHENIX, 3DB, MORSE, CIPER and SNPERT. In the course of the development, some utility programs and service programs have been additionaly developed. These are used for access of PDS file, edit of the cross sections and graphic display. Included in this report are a description of input data format of the JOINT and other programs, and of the function of each subroutine and utility programs. The usage of PDS file is also explained. In Appendix A, the input formats are described for the revised version of the CIPER code. (author)

  6. A Fast Hardware Tracker for the ATLAS Trigger System

    CERN Document Server

    Neubauer, Mark S

    2011-01-01

    In hadron collider experiments, triggering the detector to store interesting events for offline analysis is a challenge due to the high rates and multiplicities of particles produced. Maintaining high trigger efficiency for the physics we are most interested in while at the same time suppressing high rate physics from inclusive QCD processes is a difficult but important problem. It is essential that the trigger system be flexible and robust, with sufficient redundancy and operating margin. Providing high quality track reconstruction over the full ATLAS detector by the start of processing at LVL2 is an important element to achieve these needs. As the instantaneous luminosity increases, the computational load on the LVL2 system will significantly increase due to the need for more sophisticated algorithms to suppress backgrounds. The Fast Tracker (FTK) is a proposed upgrade to the ATLAS trigger system. It is designed to enable early rejection of background events and thus leave more LVL2 execution time by moving...

  7. Fast pyrolysis of corn stover using ZnCl2: Effect of washing treatment on the furfural yield and solvent extraction of furfural

    International Nuclear Information System (INIS)

    Oh, Seung-Jin; Choi, Gyung-Goo; Kim, Joo-Sik

    2015-01-01

    To produce a bio-oil having a high concentration of furfural, corn stover was fast-pyrolyzed using ZnCl 2 in a fluidized bed reactor at 330–430 °C. The effects of various parameters such as reaction temperature, water- and acid-washing prior to pyrolysis, and ZnCl 2 content on the product and furfural yields were investigated. Moreover, solvent extraction was conducted using toluene at different mass ratios of bio-oil/toluene to recover furfural from the obtained bio-oil. The maximum yield of bio-oil was 59 wt%. The bio-oil mainly comprised acetic acid, α-hydroxyketones, and furfural. The maximum furfural yield was 11.5 wt% when the feed material was water-washed, impregnated with 18.5 wt% ZnCl 2 , and pyrolyzed. Although acid-washing removed alkali and alkaline earth metals much more efficiently than water-washing, water-washing was better than acid-washing for the furfural production. Toluene extraction was very effective to recover furfural from bio-oil. The maximum recovery rate (82%) was achieved at a bio-oil/toluene ratio of 1:4. - Highlights: • Corn stover pretreated and impregnated with ZnCl 2 was successfully pyrolyzed. • Furfural was recovered from bio-oil by extraction using toluene. • Water-washing was better than acid-washing for the furfural production. • The highest furfural yield was 11.5 wt% of the product. • The highest furfural recovery rate was 82%

  8. Fast timing readout for silicon strip detectors

    International Nuclear Information System (INIS)

    Jhingan, A.; Saneesh, N.; Kumar, M.

    2016-01-01

    The development and performance of a 16 channel hybrid fast timing amplifier (FTA), for extracting timing information from silicon strip detectors (SSD), is described. The FTA will be used in a time of flight (TOF) measurement, in which one SSD is used to obtain the ion velocity (A) as well as the energy information of a scattered particle. The TOF information with a thin transmission SSD, acting as ΔE detector (Z) in a detector telescope, will provide a unique detection system for the identification of reaction products in the slowed down beam campaign of low energy branch (LEB) at NUSTAR-FAIR. Such a system will also provide large solid angle coverage with ~ 100% detection efficiency, and adequate segmentation for angular information. A good timing resolution (≤ 100 ps) enables to have shorter flight paths, thus a closely packed 4π array should be feasible. Preamplifiers for energy readout in SSD are easily available. A major constraint with SSDs is the missing high density multichannel preamplifiers which can provide both fast timing as well as energy. Provision of both timing and energy processing, generally makes circuit bulky, with higher power consumption, which may not be suitable in SSD arrays. In case of DSSSD, the problem was overcome by using timing from one side and energy from the other side. A custom designed 16 channel FTA has been developed for DSSSD design W from Micron Semiconductors, UK

  9. The Case Study of Implementing the Delivery Optimization System at a Fast-Moving Consumer Goods Distributer

    Directory of Open Access Journals (Sweden)

    Ante Galić

    2013-12-01

    Full Text Available Using new optimization methods and information-communications technology has become the key issue in the competition among the distributers of fast-moving consumer goods. Introducing a delivery optimization system instead of manual routing enables significant cost savings. The prerequisites for optimization are stable information system and efficient company management. The rich vehicle routing problem model is discussed and the effects of implementing the delivery optimization system are presented. For four years of continuous utilisation, the system has helped the distributer to reduce the overall distribution costs. It also made possible to close down several depots and handle more customer requests without investing in the vehicle fleet. The developed optimization system enabled the distributer to adapt to the new distribution schedule and react to first indicators of recession very fast. Normal 0 21 false false false HR X-NONE X-NONE

  10. A Fast hardware Tracker for the ATLAS Trigger system

    CERN Document Server

    Pandini, Carlo Enrico; The ATLAS collaboration

    2015-01-01

    The trigger system at the ATLAS experiment is designed to lower the event rate occurring from the nominal bunch crossing at 40 MHz to about 1 kHz for a designed LHC luminosity of 10$^{34}$ cm$^{-2}$ s$^{-1}$. After a very successful data taking run the LHC is expected to run starting in 2015 with much higher instantaneous luminosities and this will increase the load on the High Level Trigger system. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals, which requires a more extensive use of tracking information. The Fast Tracker (FTK) trigger system, part of the ATLAS trigger upgrade program, is a highly parallel hardware device designed to perform full-scan track-finding at the event rate of 100 kHz. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful, Field Programmable Gate Arrays form an important part of the system architecture, and the combinatorial problem of pattern r...

  11. A fast continuous magnetic field measurement system based on digital signal processors

    Energy Technology Data Exchange (ETDEWEB)

    Velev, G.V.; Carcagno, R.; DiMarco, J.; Kotelnikov, S.; Lamm, M.; Makulski, A.; /Fermilab; Maroussov, V.; /Purdue U.; Nehring, R.; Nogiec, J.; Orris, D.; /Fermilab; Poukhov,; Prakoshyn, F.; /Dubna, JINR; Schlabach, P.; Tompkins, J.C.; /Fermilab

    2005-09-01

    In order to study dynamic effects in accelerator magnets, such as the decay of the magnetic field during the dwell at injection and the rapid so-called ''snapback'' during the first few seconds of the resumption of the energy ramp, a fast continuous harmonics measurement system was required. A new magnetic field measurement system, based on the use of digital signal processors (DSP) and Analog to Digital (A/D) converters, was developed and prototyped at Fermilab. This system uses Pentek 6102 16 bit A/D converters and the Pentek 4288 DSP board with the SHARC ADSP-2106 family digital signal processor. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a rotating coil probe. Data acquisition is performed under a RTOS, whereas processing and visualization are performed under a host computer. Firmware code was developed for the DSP to perform fast continuous readout of the A/D FIFO memory and integration over specified intervals, synchronized to the probe's rotation in the magnetic field. C, C++ and Java code was written to control the data acquisition devices and to process a continuous stream of data. The paper summarizes the characteristics of the system and presents the results of initial tests and measurements.

  12. Solvent Extraction of Furfural From Biomass

    Science.gov (United States)

    Humphrey, M. F.

    1984-01-01

    Solvent-extraction method reduces energy required to remove furfural produced during acid hydrolysis of biomass. Acid hydrolysis performed in vessel containing both solvents and reacting ingredients. With intimate contact between solvents and aqueous hydrolyis liqour, furfural removed form liquor almost as fast as it forms.

  13. FAST goes underground

    International Nuclear Information System (INIS)

    Fridlund, P.S.

    1985-01-01

    The FAST-M Cost Estimating Model is a parametric model designed to determine the costs associated with mining and subterranean operations. It is part of the FAST (Freiman Analysis of Systems Techniques) series of parametric models developed by Freiman Parametric Systems, Inc. The rising cost of fossil fuels has created a need for a method which could be used to determine and control costs in mining and subterranean operations. FAST-M fills this need and also provides scheduling information. The model works equally well for a variety of situations including underground vaults for hazardous waste storage, highway tunnels, and mass transit tunnels. In addition, costs for above ground structures and equipment can be calculated. The input for the model may be on a macro or a micro level. This allows the model to be used at various stages in a project. On the macro level, only general conditions and specifications need to be known. On the micro level, the smallest details may be included. As with other FAST models, reference cases are used to more accurately predict costs and scheduling. This paper will address how the model can be used for a variety of subterranean purposes

  14. Edge turbulence measurement in Heliotron J using a combination of hybrid probe system and fast cameras

    International Nuclear Information System (INIS)

    Nishino, N.; Zang, L.; Takeuchi, M.; Mizuuchi, T.; Ohshima, S.; Kasajima, K.; Sha, M.; Mukai, K.; Lee, H.Y.; Nagasaki, K.; Okada, H.; Minami, T.; Kobayashi, S.; Yamamoto, S.; Konoshima, S.; Nakamura, Y.; Sano, F.

    2013-01-01

    The hybrid probe system (a combination of Langmuir probes and magnetic probes), fast camera and gas puffing system were installed at the same toroidal section to study edge plasma turbulence/fluctuation in Heliotron J, especially blob (intermittent filament). Fast camera views the location of the probe head, so that the probe system yields the time evolution of the turbulence/fluctuation while the camera images the spatial profile. Gas puff at the same toroidal section was used to control the plasma density and simultaneous gas puff imaging technique. Using this combined system the filamentary structure associated with magnetic fluctuation was found in Heliotron J at the first time. The other kind of fluctuation was also observed at another experiment. This combination measurement enables us to distinguish MHD activity and electro-static activity

  15. In nondiabetic, human immunodeficiency virus-infected patients with lipodystrophy, hepatic insulin extraction and posthepatic insulin clearance rate are decreased in proportion to insulin resistance

    DEFF Research Database (Denmark)

    Haugaard, Steen B; Andersen, Ove; Hansen, Birgitte R

    2005-01-01

    In healthy, nondiabetic individuals with insulin resistance, fasting insulin is inversely correlated to the posthepatic insulin clearance rate (MCRi) and the hepatic insulin extraction (HEXi). We investigated whether similar early mechanisms to facilitate glucose homeostasis exist in nondiabetic...... endogenous insulin secretion, which was estimated by deconvolution of C-peptide concentrations. Hepatic extraction of insulin was calculated as 1 minus the ratio of fasting posthepatic insulin delivery rate to fasting endogenous insulin secretion rate. Compared with controls, LIPO displayed increased fasting...... insulin (130%, P Hepatic extraction of insulin was similar between groups (LIPO, 55%; controls, 57%; P > .8). In LIPO, HEXi and MCRi correlated inversely with fasting insulin (r = -0.56, P

  16. Changes of serum alkaline phosphatase isoenzymes in fasted rats.

    Science.gov (United States)

    Wada, H; Niwa, N; Hayakawa, T; Tsuge, H

    1996-10-01

    Changes of serum alkaline phosphatase (sALP) isoenzymes under fasting conditions were examined using polyacrylamide gel electrophoresis (PAGE), amino-acids (L-phenylalanine (L-Phe), L-homoarginine (L-HArg)) inhibition and wheat germ agglutinin (WGA) treatment. The sALP of non-fasted rats was separated into three bands (S1, S2, S3) by PAGE. The molecular weight (M.W.) of S1 corresponded to that of an isoenzyme found in the ileum. By the addition of L-Phe, the staining intensity of S1 was weakened, S2 and S3 remained unchanged and the total activity of the isoenzymes extracted from intestine decreased. On the other hand, the activity of isoenzymes extracted from kidney and bone decreased by the addition of L-HArg. Therefore, S1 was judged to be derived from intestine. The activities of total sALP and S1 decreased from 16 h of fasting. Total sALP activity and sALP activity of the supernatant prepared by WGA treatment decreased, whereas the ALP activity of the precipitate (difference between total sALP activity and supernatant sALP activity) did not change. The activity band of the precipitate corresponded to that of S3 by PAGE. Therefore, S3 was judged to be derived from bone. In conclusion, under fasting conditions, the activity of S1 decreased while the activities of S2 and S3 remained unchanged.

  17. Air-cooled fast discharge resistors for ITER magnets

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lokiev, Vladimir; Roshal, Alexander; Song, Inho; Buzykin, Oleg

    2011-01-01

    The ITER superconducting magnets will store up to 50 GJ of magnetic energy per operation cycle. In case of coil quench the energy stored in the coils must be extracted rapidly with a time constant from 7.5 to 14 s. It will be achieved by fast discharge resistors (FDR) normally bridged by circuit breakers and inserted in series with the superconducting coils. The fast discharge of the coils results practically in adiabatic heating of the resistive elements up to 200-300 deg. C. The resistors need to be cooled to the initial temperature over 6-8 h. Natural air circulation is proposed as a cooling method. In order to simulate the temperature response of the resistors to energy released in the resistive plates and to demonstrate their cooling capability within the required time by natural air circulation the numerical model of the resistor cooling circuit has been developed. As the calculations have shown, the developed FDR cooling system based on cooling by natural air circulation is capable of providing the required temperature operation regime of FDRs, but the supply channels are to be optimized so that the cooling time does not exceed the permissible one.

  18. Extent of pyrolysis impacts on fast pyrolysis biochar properties.

    Science.gov (United States)

    Brewer, Catherine E; Hu, Yan-Yan; Schmidt-Rohr, Klaus; Loynachan, Thomas E; Laird, David A; Brown, Robert C

    2012-01-01

    A potential concern about the use of fast pyrolysis rather than slow pyrolysis biochars as soil amendments is that they may contain high levels of bioavailable C due to short particle residence times in the reactors, which could reduce the stability of biochar C and cause nutrient immobilization in soils. To investigate this concern, three corn ( L.) stover fast pyrolysis biochars prepared using different reactor conditions were chemically and physically characterized to determine their extent of pyrolysis. These biochars were also incubated in soil to assess their impact on soil CO emissions, nutrient availability, microorganism population growth, and water retention capacity. Elemental analysis and quantitative solid-state C nuclear magnetic resonance spectroscopy showed variation in O functional groups (associated primarily with carbohydrates) and aromatic C, which could be used to define extent of pyrolysis. A 24-wk incubation performed using a sandy soil amended with 0.5 wt% of corn stover biochar showed a small but significant decrease in soil CO emissions and a decrease in the bacteria:fungi ratios with extent of pyrolysis. Relative to the control soil, biochar-amended soils had small increases in CO emissions and extractable nutrients, but similar microorganism populations, extractable NO levels, and water retention capacities. Corn stover amendments, by contrast, significantly increased soil CO emissions and microbial populations, and reduced extractable NO. These results indicate that C in fast pyrolysis biochar is stable in soil environments and will not appreciably contribute to nutrient immobilization. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  19. Coupled fast-thermal system at the RB, masters thesis; Spregnuti brzo-termicki sistem na reaktoru RB, magistarski rad

    Energy Technology Data Exchange (ETDEWEB)

    Pesic, M [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1984-05-15

    Coupled fast-thermal system at the RB reactor was formed owing to availability of highly enriched fuel. This paper deals with reactor parameters calculations and measurements of coupled core taking into account safety constraints. Validity of applied calculation methods was confirmed. The following parameters were analyzed: critical height of the core; reactivity dependent on heavy water level in the core; fast neutron spectrum in the fast region channel; spatial distribution of thermal. epithermal and fat neutrons in the fast region channel; reactivity of safety rods; neutron and gamma absorption doses in the center of the coupled core.

  20. Knowledge management in fast reactors

    International Nuclear Information System (INIS)

    Kuriakose, K.K.; Satya Murty, S.A.V.; Swaminathan, P.; Raj, Baldev

    2010-01-01

    This paper highlights the work that is being carried out in Knowledge Management of Fast Reactors at Indira Gandhi Centre for Atomic Research (IGCAR) including a few examples of how the knowledge acquired because of various incidents in the initial years has been utilized for the successful operation of Fast Breeder Test Reactor. It also briefly refers to the features of the IAEA initiative on the preservation of Knowledge in the area of Fast Reactors in the form of 'Fast Reactor Knowledge Organization System' (FR-KOS), which is based on a taxonomy for storage and mining of Fast Reactor Knowledge. (author)

  1. Experimental possibilities and fast neutron dose map of the fast neutron fields at the RB reactor facility

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.; Pesic, M.; Antic, D.; Ninkovic, M.

    1993-01-01

    The RB is an unshielded, zero power nuclear facility with natural and enriched uranium fuel (2% and 80%) and D 2 O as moderator. It is possible to create different configurations of non-reflected and partially reflected critical systems and to make experiments in the fields of thermal neutrons. The fields of fast neutrons with 'softened' fission spectrum are made by modifying the system: modified experimental fuel channel EFC, coupled fast-thermal system in two configurations CFTS-1 and CFTS-2, coupled fast-thermal core HERBE. The intermediate and fast neutron absorbed doses in fast neutron fields are given. In first configuration of RB reactor it was almost impossible to perform dosimetric and other experiments. By creating these fields, with in our circumstances available fuel elements, the possibilities for different experiments are greatly improved. Now we can irradiate food samples, soil samples, electronic devices, study material properties, perform various dosimetry experiments, etc. (1 tab.)

  2. Extraction of Oxytetracycline Hydrochloride in Aqueous Two-phase System of Acetone and Ammonium Sulfate

    International Nuclear Information System (INIS)

    Han, J.

    2013-01-01

    Summary: Aqueous two-phase system (ATPS) is an efficient implement for separation of various substrates, and extracted by an aqueous two-phase system has been successful ly applied in the downstream processing of various biological compounds. In this research, the extraction of oxytetracycline hydrochloride (OTC-HCl) was carried out in an aqueous two-phase system containing acetone and ammonium sulfate solution, which partitioned the antibiotic to the upper phase. The effects of some parameters on the extraction efficiency of OTC-HCl were studied in detail, including temperature, the volume of acetone, the pH value of ammonium sulfate solution, the concentrations of (NH/sub 4/)/sub 2/ SO/sub 4/ and OTC-HCl. The results showed that the volume of acetone, the pH value of ammonium sulfate solution and the concentration of OTC-HCl in feed had significant effects on the extraction efficiency of OTC-HCl, but the effects of temperature on the extraction of OTC-HCl was not obvious. (author)

  3. Extraction of Oxytetracycline Hydrochloride in Aqueous Two-phase System of Acetone and Ammonium Sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Han, J. [Jiangsu Univ., Zhenjiang (China). Dept. of Food and Biological Engineering

    2013-02-15

    Summary: Aqueous two-phase system (ATPS) is an efficient implement for separation of various substrates, and extracted by an aqueous two-phase system has been successful ly applied in the downstream processing of various biological compounds. In this research, the extraction of oxytetracycline hydrochloride (OTC-HCl) was carried out in an aqueous two-phase system containing acetone and ammonium sulfate solution, which partitioned the antibiotic to the upper phase. The effects of some parameters on the extraction efficiency of OTC-HCl were studied in detail, including temperature, the volume of acetone, the pH value of ammonium sulfate solution, the concentrations of (NH/sub 4/)/sub 2/ SO/sub 4/ and OTC-HCl. The results showed that the volume of acetone, the pH value of ammonium sulfate solution and the concentration of OTC-HCl in feed had significant effects on the extraction efficiency of OTC-HCl, but the effects of temperature on the extraction of OTC-HCl was not obvious. (author)

  4. Recent advances in automated system model extraction (SME)

    International Nuclear Information System (INIS)

    Narayanan, Nithin; Bloomsburgh, John; He Yie; Mao Jianhua; Patil, Mahesh B; Akkaraju, Sandeep

    2006-01-01

    In this paper we present two different techniques for automated extraction of system models from FEA models. We discuss two different algorithms: for (i) automated N-DOF SME for electrostatically actuated MEMS and (ii) automated N-DOF SME for MEMS inertial sensors. We will present case studies for the two different algorithms presented

  5. The Fast TracKer

    CERN Document Server

    Potamianos, Karolos Jozef; The ATLAS collaboration

    2018-01-01

    The Fast Tracker (FTK) is a hardware upgrade to the ATLAS trigger and data acquisition system providing global track reconstruction to the High-Level Trigger (HLT) with the goal to improve pile-up rejection. The FTK processes incoming data from the Pixel and SCT detectors (part of the Inner Detector, ID) at up to 100 kHz using custom electronic boards. ID hits are matched to pre-defined track patterns stored in associative memory (AM) on custom ASICs and data routing, reduction and parameter extraction is achieved with processing on FPGAs. With 8000 AM chips and 2000 FPGAs, the FTK provides enough resources to reconstruct tracks with transverse momentum greater than 1 GeV/c in the whole tracking volume with an average latency below 100 microseconds at collisions intensities expected in Runs II and III of the LHC. The tracks will be available at the beginning of the trigger selection process, which allows development of pile-up resilient triggering strategies to identify b-quarks and tau-leptons, as well as pr...

  6. Optimization of protein extraction process from jackfruit seed flour by reverse micelle system

    Directory of Open Access Journals (Sweden)

    Maycon Fagundes Teixeira Reis

    2016-06-01

    Full Text Available The extraction of protein from flour of jackfruit seeds by reverse micelles was evaluated. Reverse micelle system was composed of sodium dodecyl sulfate (SDS as surfactant, butanol as solvent, and water. The effects of stirring time, temperature, molar ratio H2O SDS-1, concentration of butanol (mass percentage and flour mass were tested in batch systems. Based on the adjusted linear regression model, only butanol concentration provided optimum extraction conditions (41.16%. Based on the analysis of surface response, the best extraction yield could be obtained at 25°C, stirring time of 120 min, mass of flour of 100 mg, and a ratio H2O SDS-1 of 50. Experimental results showed that a 79.00% extraction yield could be obtained.

  7. Towards a slow extraction system for the TRIUMF Kaon factory extender ring with 0.1% losses

    International Nuclear Information System (INIS)

    Wienands, U.; Servranckx, R.V.

    1988-03-01

    In order to reduce extraction losses a modified third-integral slow extraction system is proposed using a 0.5 m long and 10 μm thin electrostatic preseptum. Various factors limiting the extraction efficiency are investigated, and the losses are estimated to be as low as 0.2%. The extracted beam emittance is found to be about 0.2 π mm-mrad for achromatic extraction. For chromatic extraction a reduction in momentum width of the extracted beam by a factor of 2.5 will result in an extracted momentum bite of less than 30 MeV/c FWHM. This figure is limited by emittance blow-up due to synchrotron oscillations, which in turn increases extraction losses. Following the analytical estimate of the performance of the extraction system, simulation results are shown

  8. Development of a Neutron Flux Monitoring System for Sodium-cooled Fast Reactors

    OpenAIRE

    Verma, Vasudha

    2017-01-01

    Safety and reliability are one of the key objectives for future Generation IV nuclear energy systems. The neutron flux monitoring system forms an integral part of the safety design of a nuclear reactor and must be able to detect any irregularities during all states of reactor operation. The work in this thesis mainly concerns the detection of in-core perturbations arising from unwanted movements of control rods with in-vessel neutron detectors in a sodium-cooled fast reactor. Feasibility stud...

  9. Ultrahigh-brightness KrF laser system for fast ignition studies

    International Nuclear Information System (INIS)

    Shaw, M.J.; Ross, I.N.; Hooker, C.J.; Dodson, J.M.; Hirst, G.J.; Lister, J.M.D.; Divall, E.J.; Kidd, A.K.; Hancock, S.; Damerell, A.R.; Wyborn, B.E.

    1999-01-01

    The main requirements for a fast igniter laser beam are reviewed and shown to favour short wavelength and ultrahigh brightness. These requirements are met by the new KrF laser system at Rutherford Appleton Laboratory called TITANIA. TITANIA uses two schemes to enhance the laser beam brightness. The first is chirped pulse amplification which is used to enhance brightness by compressing the pulse into the femtosecond region. In this mode TITANIA produces in the region of 250 mJ on target in 700 fs. The second mode of operation uses a Raman technique for beam combining and beam clean-up which is designed to give a single beam of 80 Joules on target in a pulselength of 60 ps. In this scheme the KrF wavelength is Raman shifted to 268 nm. The Raman amplifiers will use gaseous rather than solid windows and experiments which demonstrate their feasibility will be described. A concept for a reactor scale fast igniter beam using the Raman technique will be discussed. (orig.)

  10. Solid-phase extraction with the metal-organic framework MIL-101(Cr) combined with direct analysis in real time mass spectrometry for the fast analysis of triazine herbicides.

    Science.gov (United States)

    Li, Xianjiang; Xing, Jiawei; Chang, Cuilan; Wang, Xin; Bai, Yu; Yan, Xiuping; Liu, Huwei

    2014-06-01

    MIL-101(Cr) is an excellent metal-organic framework with high surface area and nanoscale cavities, making it promising in solid-phase extraction. Herein, we used MIL-101(Cr) as a solid-phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART-MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL-101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1∼0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5∼1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85∼110%. These results showed that solid-phase extraction with metal-organic frameworks is an efficient sample preparation approach for DART-MS analysis and could find more applications in environmental analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The general properties of water - nitrobenzene - crown - bis-1,2-dicarbollylcobaltate extraction systems

    International Nuclear Information System (INIS)

    Vanura, P.

    2003-01-01

    The extraction and stability constants in the system water - nitrobenzene have been collected and general rules valid for water - nitrobenzene - crown - bis-1,2-dicarbollylcobaltate extraction system have been found. The main principles are size compatibility of ion diameter and crown cavity diameters, the flexibility of crown, the basicity of crown and the steric factor of both the ligand and the extracted ion. The extraction in the system water - mineral acid or salt polyoxyethylene compound - bis-1,2-dicarbollylcobaltate - nitrobenzene is more complicated than can be expected from usually used ion diameter - crown cavity diameter compatibility principle. The other important factors are the basicity and the deformability of crown, steric aspect and the angles of bonds of extracted ion. The binuclear 'sandwich' complexes with H + ion and Sr 2+ or Ba 2+ ions have been proved for dibenzo-18-crown-6 (DB18C6). On the other hand, only SrL 2 and BaL 2 (L = 15C5) complexes are formed in nitrobenzene saturated with water. The addition of polyoxyethylene compound usually increases the distribution ratio of alkali earth metal ions and the selectivity of its mutual separation. (authors)

  12. Overview of tritium fast-fission yields

    International Nuclear Information System (INIS)

    Tanner, J.E.

    1981-03-01

    Tritium production rates are very important to the development of fast reactors because tritium may be produced at a greater rate in fast reactors than in light water reactors. This report focuses on tritium production and does not evaluate the transport and eventual release of the tritium in a fast reactor system. However, if an order-of-magnitude increase in fast fission yields for tritium is confirmed, fission will become the dominant production source of tritium in fast reactors

  13. Simulation of the Plasma Meniscus with and without Space Charge using Triode Extraction System

    International Nuclear Information System (INIS)

    Abdel Rahman, M.M.; EI-Khabeary, H.

    2007-01-01

    In this work simulation of the singly charged argon ion trajectories for a variable plasma meniscus is studied with and without space charge for the triode extraction system by using SIMION 3D (Simulation of Ion Optics in Three Dimensions) version 7 personal computer program. Tbe influence of acceleration voltage applied to tbe acceleration electrode of the triode extraction system on the shape of the plasma meniscus has been determined. The plasma electrode is set at +5000 volt and the acceleration voltage applied to the acceleration electrode is varied from -5000 volt to +5000 volt. In the most of the concave and convex plasma shapes ion beam emittance can be calculated by using separate standard deviations of positions and elevations angles. Ion beam emittance as a function of the curvature of the plasma meniscus for different plasma shapes ( flat concave and convex ) without space change at acceleration voltage varied from -5000 volt to +5000 volt applied to the acceleration electrode of the triode extraction system has been investigated. Tbe influence of the extraction gap on ion beam emittance for a plasma concave shape of 3.75 mm without space charge at acceleration voltage, V a cc = -2000 volt applied to the acceleration electrode of the triode extraction system has been determined. Also the influence of space charge on ion beam emittance for variable plasma meniscus at acceleration voltage, V a cc = - 2000 volt applied to the acceleration electrode of. the triode extraction system has been studied

  14. Simulation of the plasma meniscus with and without space charge using triode extraction system

    International Nuclear Information System (INIS)

    Rahman, M.M.Abdel; El-Khabeary, H.

    2009-01-01

    In this work, simulation of the singly charged argon ion trajectories for a variable plasma meniscus is studied with and without space charge for the triode extraction system by using SIMION 3D (Simulation of Ion Optics in Three Dimensions) version 7 personal computer program. The influence of acceleration voltage applied to the acceleration electrode of the triode extraction system on the shape of the plasma meniscus has been determined. The plasma electrode is set at +5000 volt and the acceleration voltage applied to the acceleration electrode is varied from -5000 volt to +5000 volt. In the most of the concave and convex plasma shapes, ion beam emittance can be calculated by using separate standard deviations of positions and elevations angles. Ion beam emittance as a function of the curvature of the plasma meniscus for different plasma shapes ( flat, concave and convex ) without space charge at acceleration voltage varied from -5000 volt to +5000 volt applied to the acceleration electrode of the triode extraction system has been investigated. The influence of the extraction gap on ion beam emittance for a plasma concave shape of 3.75 mm without space charge at acceleration voltage, V acc = -2000 volt applied to the acceleration electrode of the triode extraction system has been determined. Also the influence of space charge on ion beam emittance for variable plasma meniscus at acceleration voltage, V acc = -2000 volt applied to the acceleration electrode of the triode extraction system has been studied. (author)

  15. Analysis of entropy extraction efficiencies in random number generation systems

    Science.gov (United States)

    Wang, Chao; Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Han, Zheng-Fu

    2016-05-01

    Random numbers (RNs) have applications in many areas: lottery games, gambling, computer simulation, and, most importantly, cryptography [N. Gisin et al., Rev. Mod. Phys. 74 (2002) 145]. In cryptography theory, the theoretical security of the system calls for high quality RNs. Therefore, developing methods for producing unpredictable RNs with adequate speed is an attractive topic. Early on, despite the lack of theoretical support, pseudo RNs generated by algorithmic methods performed well and satisfied reasonable statistical requirements. However, as implemented, those pseudorandom sequences were completely determined by mathematical formulas and initial seeds, which cannot introduce extra entropy or information. In these cases, “random” bits are generated that are not at all random. Physical random number generators (RNGs), which, in contrast to algorithmic methods, are based on unpredictable physical random phenomena, have attracted considerable research interest. However, the way that we extract random bits from those physical entropy sources has a large influence on the efficiency and performance of the system. In this manuscript, we will review and discuss several randomness extraction schemes that are based on radiation or photon arrival times. We analyze the robustness, post-processing requirements and, in particular, the extraction efficiency of those methods to aid in the construction of efficient, compact and robust physical RNG systems.

  16. Electrical probe diagnostic with fast data acquisition systems of the Novillo tokamak

    International Nuclear Information System (INIS)

    Lopez-Callejas, R.; Benitez-Read, J.S.; Longoria-Gandara, L.C.; Pacheco-Sotelo, J.O.; Valencia-Alvarado, R.; Tamayo, F.J.; Valdes, A.; Fernandez, M.C.; Serrano, F.

    2001-01-01

    This paper describes the electrical probe diagnostic system used to measure the relevant parameters of the plasma column generated in the Novillo tokamak, and an inexpensive and fast data acquisition system that consists of 16 independent channels, 8 bit resolution, sampling frequency of 500 kHz, and 8 kword memory per channel. A distributed, modular and transparent approach was used for designing the software-operated data acquisition, diagnostic, and capacitor banks triggering systems, satisfying the pulsed nature of the tokamak discharge. Through a personal computer, the experimental data are available to engineers and physicists in a centralized database

  17. Some aspects of fast reactor economics

    International Nuclear Information System (INIS)

    Kazachkovskij, O.D.

    1996-01-01

    Expedient approach to evaluation of economic efficiency of fast reactors is discussed. It is concluded that determination of electric power generation cost should be based on the fact, that plutonium cost is dictated only by expenses for its extraction from the spent fuel. The cost of the first critical load is not included into capital investments, and investment charges should be sufficiently lower, than standard ones. 5 refs

  18. Use of ethyl lactate to extract bioactive compounds from Cytisus scoparius: Comparison of pressurized liquid extraction and medium scale ambient temperature systems.

    Science.gov (United States)

    Lores, Marta; Pájaro, Marta; Álvarez-Casas, Marta; Domínguez, Jorge; García-Jares, Carmen

    2015-08-01

    An important trend in the extraction of chemical compounds is the application of new environmentally friendly, food grade solvents. Ethyl lactate (ethyl 2-hydroxypropanoate), produced by fermentation of carbohydrates, is miscible with both hydrophilic and hydrophobic compounds being a potentially good solvent for bioactive compounds. Despite its relatively wide use as a general solvent, the utilization of ethyl lactate as an extraction solvent has only recently been considered. Here, we evaluate the possible use of ethyl lactate to extract phenolic compounds from wild plants belonging to Cytisus scoparius, and we compare the characteristics of the extracts obtained by Pressurized Solvent Extraction (the total phenolics content, the antioxidant activity and the concentration of the major polyphenols) with those of other extracts obtained with methanol. In order to explore the industrial production of the ethyl lactate Cytisus extract, we also evaluate medium scale ambient temperature setups. The whole plant and the different parts (flowers, branches, and seed pods) were evaluated separately as potential sources of polyphenols. All extracts were analyzed by LC-MS/MS for accurate identification of the major polyphenols. Similar phenolic profiles were obtained when using ethyl lactate or methanol. The main bioactives found in the Cytisus extract were the non-flavonoid phenolic compounds caffeic and protocatechuic acids and 3,4-dihydroxybenzaldehyde; the flavonoids rutin, kaempferol and quercetin; the flavones chrysin, orientin and apigenin; and the alkaloid lupanine. Regarding the comparison of the extraction systems, although the performance of the PLE was much better than that of the ambient-temperature columns, the energy consumption was also much higher. Ethyl lactate has resulted an efficient extraction solvent for polyphenols from C. scoparius, yielding extracts with high levels of plant phenolics and antioxidant activity. The antimicrobial activity of these

  19. Evaluation of various solvent systems for lipid extraction from wet microalgal biomass and its effects on primary metabolites of lipid-extracted biomass.

    Science.gov (United States)

    Ansari, Faiz Ahmad; Gupta, Sanjay Kumar; Shriwastav, Amritanshu; Guldhe, Abhishek; Rawat, Ismail; Bux, Faizal

    2017-06-01

    Microalgae have tremendous potential to grow rapidly, synthesize, and accumulate lipids, proteins, and carbohydrates. The effects of solvent extraction of lipids on other metabolites such as proteins and carbohydrates in lipid-extracted algal (LEA) biomass are crucial aspects of algal biorefinery approach. An effective and economically feasible algae-based oil industry will depend on the selection of suitable solvent/s for lipid extraction, which has minimal effect on metabolites in lipid-extracted algae. In current study, six solvent systems were employed to extract lipids from dry and wet biomass of Scenedesmus obliquus. To explore the biorefinery concept, dichloromethane/methanol (2:1 v/v) was a suitable solvent for dry biomass; it gave 18.75% lipids (dry cell weight) in whole algal biomass, 32.79% proteins, and 24.73% carbohydrates in LEA biomass. In the case of wet biomass, in order to exploit all three metabolites, isopropanol/hexane (2:1 v/v) is an appropriate solvent system which gave 7.8% lipids (dry cell weight) in whole algal biomass, 20.97% proteins, and 22.87% carbohydrates in LEA biomass. Graphical abstract: Lipid extraction from wet microalgal biomass and biorefianry approach.

  20. Startup Report for Ground Water Extraction, Treatment, and Recharge System

    National Research Council Canada - National Science Library

    Lamb, Steve

    1997-01-01

    The document presents startup procedures, observations and measurements conducted during the startup of the Groundwater Extraction, Treatment and Recharge System, built for the 162nd Fighter Wing, Air...

  1. Development of a nuclear information system for the MONJU Fast Breeder Reactor

    International Nuclear Information System (INIS)

    Metz, Peter

    2000-01-01

    At the MONJU Fast Breeder Reactor information is collected on a continuous basis. This information consists of measured data, design data, simulations data, maintenance data etc. which may be in any kind of electronic form, i.e. text documents, code input files, reports or even scanned documents. The amount and nature of these data has introduced the need for a software system, which will provide an efficient infrastructure for the maintenance of and operations on the data. Thus a Nuclear Information System for the MONJU Fast Breeder Reactor is under development. The system consists of remote databases hosting the information along with clients for handling them, remote clients providing the users with an interface and a local server for handling the client requests and the communication between the database and user clients. The system is composed of independent server, database and user modules, which communicates using the RMI-IIOP (Remote Method Invocation - Internet InterORB Protocol) technology. The RMI-IIOP is a CORBA (Common Object Request Broker Architecture) compliant subset of the RMI thereby facilitating the possibility of implementing the database and user modules in any kind of programming language and on any kind of operating system by providing a standard, platform independent communications interface. The user interface consists of dynamic HTML web pages which instantiates servlets in the user module when the user submits queries. The database module consists of controllers for handling the communication with the user module and database drivers for handling the connections with the databases. In this paper the overall system design and schemes for data flow and remote method invocations are presented and the requirements imposed on the system are discussed. (author)

  2. Hard cap espresso extraction and liquid chromatography determination of bioactive compounds in vegetables and spices.

    Science.gov (United States)

    Martinez-Sena, María Teresa; de la Guardia, Miguel; Esteve-Turrillas, Francesc A; Armenta, Sergio

    2017-12-15

    A new analytical procedure, based on liquid chromatography with diode array and fluorescence detection, has been proposed for the determination of bioactive compounds in vegetables and spices after hard cap espresso extraction. This novel extraction system has been tested for the determination of capsaicin and dihydrocapsaicin from fresh chilli and sweet pepper, piperine from ground pepper, curcumin from turmeric and curry, and myristicin from nutmeg. Extraction efficiency was evaluated by using acetonitrile:water and ethanol:water mixtures. The proposed method allows the extraction of samples with 100mL of 60% (v/v) ethanol in water. The obtained limits of quantification for the proposed procedure ranged from 0.07 to 0.30mgg -1 and results were statistically comparable with those obtained by ultrasound assisted extraction. Hard cap espresso machines offer a fast, effective and quantitative tool for the extraction of bioactive compounds from food samples with an extraction time lower than 30s, using a global available and low cost equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. RF power diagnostics and control on the DIII-D, 4 MW 30--120 MHz fast wave current drive system (FWCD)

    International Nuclear Information System (INIS)

    Ferguson, S.W.; Allen, J.C.; Callis, R.W.; Cary, W.P.; Harris, T.E.

    1995-10-01

    The Fast Wave Current Drive System uses three 2 MW transmitters to drive three antennas inside the DIII-D vacuum vessel. This paper describes the diagnostics for this system. The diagnostics associated with the General Atomics Fast Wave Current Drive System allow the system tuning to be analyzed and modified on a between shot basis. The transmitters can be exactly tuned to match the plasma with only one tuning shot into the plasma. This facilitates maximum rf power utilization

  4. Sensor-Based Auto-Focusing System Using Multi-Scale Feature Extraction and Phase Correlation Matching

    Directory of Open Access Journals (Sweden)

    Jinbeum Jang

    2015-03-01

    Full Text Available This paper presents a novel auto-focusing system based on a CMOS sensor containing pixels with different phases. Robust extraction of features in a severely defocused image is the fundamental problem of a phase-difference auto-focusing system. In order to solve this problem, a multi-resolution feature extraction algorithm is proposed. Given the extracted features, the proposed auto-focusing system can provide the ideal focusing position using phase correlation matching. The proposed auto-focusing (AF algorithm consists of four steps: (i acquisition of left and right images using AF points in the region-of-interest; (ii feature extraction in the left image under low illumination and out-of-focus blur; (iii the generation of two feature images using the phase difference between the left and right images; and (iv estimation of the phase shifting vector using phase correlation matching. Since the proposed system accurately estimates the phase difference in the out-of-focus blurred image under low illumination, it can provide faster, more robust auto focusing than existing systems.

  5. ANTIMICROBIAL ACTION OF THE LEAF EXTRACT OF MORINGA OLEIFERA LAM.

    Science.gov (United States)

    Pal, Saroj K.; Mukherjee, Pulok K.; Saha, Kakali; Pal, M.; Saha, B.P.

    1995-01-01

    The ethnolic extract of the leaves of Moringa oleifera Lam. (Fam. Moringaceae) was tested for antimicrobial activities against Gram Positive – Bacillus cereus, Bacillus subtilis Staphylococcus aureus, Sarcina lutea: Gram negative – Escherichia coli and Acid fast Mycobacterium phlei. Significant antimicrobial activity of the extract was found in this study. PMID:22556699

  6. The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Chen Ligang; Ding Lan; Jin Haiyan; Song Daqian; Zhang Huarong; Li Jiantao; Zhang Kun; Wang Yutang; Zhang Hanqi

    2007-01-01

    A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM 010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min -1 . The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g -1 . The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required

  7. EC-FP7 ARCAS: technical and economical comparison of Fast Reactors and Accelerator Driven Systems for transmutation of Minor Actinides

    International Nuclear Information System (INIS)

    Van den Eynde, G.; Romanello, V.; Heek, A. van; Martin-Fuertes, F.; Zimmerman, C.; Lewin, B.

    2015-01-01

    The ARCAS project aims to compare, on a technological and economical basis, Accelerator Driven Systems and Fast Reactors as Minor Actinide burners. It is split in five work packages: the reference scenario definition, the fast reactor system definition, the accelerator driven system definition, the fuel reprocessing and fabrication facilities definition and the economical comparison. This paper summarizes the status of the project and its five work packages. (author)

  8. System-level Specifications of the Timing and Fast Control system for the LHCb Upgrade

    CERN Document Server

    Alessio, Federico

    2014-01-01

    The LHCb experiment has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times the initial design luminosity. The various sub-systems in the readout architecture will need to be upgraded in order to cope with higher sub-detector occupancies, higher rate and higher network load. In this paper, we describe the specifications of the new Timing and Fast Control (S- TFC) system. We define the requirements for the new S-TFC, and specify its architecture and the individual components. The system is based on a single new Readout Supervisor (S-ODIN) instantiating several S-TFC masters to allow partitioning. The communication with the readout electronics is ensured by a shared high-speed optical link network for both the distribution of timing and synchronous control information, as well as trigger/throttle communication. An interface board (SOL40) with fan-out capabilities for timing and synchronous information and fan-in capabilities for throttle and rate regulation of the...

  9. Astrid (fast breeder nuclear reactor)

    International Nuclear Information System (INIS)

    2014-01-01

    This document presents ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration), a French project of sodium-cooled fast breeder reactor, fourth generation reactor which should be fuelled by uranium 238 rather than uranium 235, and should therefore need less extracted natural uranium to produce electricity. The operation principle of fast breeder reactors is described. They notably directly consume plutonium, allow an easier radioactive waste management as they transform long life radioactive elements into shorter life elements by transmutation. The regeneration process is briefly described, and the various operation modes are evoked (iso-generator, sub-generator, and breeder). Some peculiarities of sodium-cooled reactors are outlined. The Astrid operation principle is described, its main design innovations outlined. Various challenges are discussed regarding safety of supply and waste processing, and the safety of future reactors. Major actors are indicated: CEA, Areva, EDF, SEIV Alcen, Toshiba, Rolls Royce, and Comex. Some key data are indicated: expected lifetime, expected availability rate, cost. The projected site is Marcoule and fast breeder reactors operated or under construction in the world are indicated. The document also proposes an overview of the background and evolution of reactors of 4. generation

  10. Detection and Extraction of Roads from High Resolution Satellites Images with Dynamic Programming

    Science.gov (United States)

    Benzouai, Siham; Smara, Youcef

    2010-12-01

    The advent of satellite images allows now a regular and a fast digitizing and update of geographic data, especially roads which are very useful for Geographic Information Systems (GIS) applications such as transportation, urban pollution, geomarketing, etc. For this, several studies have been conducted to automate roads extraction in order to minimize the manual processes [4]. In this work, we are interested in roads extraction from satellite imagery with high spatial resolution (at best equal to 10 m). The method is semi automatic and follows a linear approach where road is considered as a linear object. As roads extraction is a pattern recognition problem, it is useful, above all, to characterize roads. After, we realize a pre-processing by applying an Infinite Size Edge Filter -ISEF- and processing method based on dynamic programming concept, in particular, Fishler algorithm designed by F*.

  11. Radiator Enhanced Geothermal System - A Revolutionary Method for Extracting Geothermal Energy

    Science.gov (United States)

    Karimi, S.; Marsh, B. D.; Hilpert, M.

    2017-12-01

    A new method of extracting geothermal energy, the Radiator Enhanced Geothermal System (RAD-EGS) has been developed. RAD-EGS attempts to mimic natural hydrothermal systems by 1) generating a vertical vane of artificially produced high porosity/permeability material deep in a hot sedimentary aquifer, 2) injecting water at surface temperatures to the bottom of the vane, where the rock is the hottest, 3) extracting super-heated water at the top of the vane. The novel RAD-EGS differs greatly from the currently available Enhanced Geothermal Systems in vane orientation, determined in the governing local crustal stress field by Shmax and Sl (meaning it is vertical), and in the vane location in a hot sedimentary aquifer, which naturally increases the longevity of the system. In this study, we explore several parameters regimes affecting the water temperature in the extraction well, keeping in mind that the minimum temperature of the extracted water has to be 150 °C in order for a geothermal system to be commercially viable. We used the COMSOL finite element package to simulate coupled heat and fluid transfer within the RAD-EGS model. The following geologic layers from top to bottom are accounted for in the model: i) confining upper layer, ii) hot sedimentary aquifer, and iii) underlying basement rock. The vane is placed vertically within the sedimentary aquifer. An injection well and an extraction well are also included in the simulation. We tested the model for a wide range of various parameters including background heat flux, thickness of geologic layers, geometric properties of the vane, diameter and location of the wells, fluid flow within the wells, regional hydraulic gradient, and permeability and porosity of the layers. The results show that among the aforementioned parameters, background heat flux and the depth of vane emplacement are highly significant in determining the level of commercial viability of the geothermal system. These results indicate that for the

  12. A green deep eutectic solvent-based aqueous two-phase system for protein extracting

    International Nuclear Information System (INIS)

    Xu, Kaijia; Wang, Yuzhi; Huang, Yanhua; Li, Na; Wen, Qian

    2015-01-01

    Highlights: • A strategy for the protein purification with a deep eutectic solvent(DES)-based aqueous two-phase system. • Choline chloride-glycerin DES was selected as the extraction solvent. • Bovine serum albumin and trypsin were used as the analytes. • Aggregation phenomenon was detected in the mechanism research. - Abstract: As a new type of green solvent, deep eutectic solvent (DES) has been applied for the extraction of proteins with an aqueous two-phase system (ATPS) in this work. Four kinds of choline chloride (ChCl)-based DESs were synthesized to extract bovine serum albumin (BSA), and ChCl-glycerol was selected as the suitable extraction solvent. Single factor experiments have been done to investigate the effects of the extraction process, including the amount of DES, the concentration of salt, the mass of protein, the shaking time, the temperature and PH value. Experimental results show 98.16% of the BSA could be extracted into the DES-rich phase in a single-step extraction under the optimized conditions. A high extraction efficiency of 94.36% was achieved, while the conditions were applied to the extraction of trypsin (Try). Precision, repeatability and stability experiments were studied and the relative standard deviations (RSD) of the extraction efficiency were 0.4246% (n = 3), 1.6057% (n = 3) and 1.6132% (n = 3), respectively. Conformation of BSA was not changed during the extraction process according to the investigation of UV–vis spectra, FT-IR spectra and CD spectra of BSA. The conductivity, dynamic light scattering (DLS) and transmission electron microscopy (TEM) were used to explore the mechanism of the extraction. It turned out that the formation of DES–protein aggregates play a significant role in the separation process. All the results suggest that ChCl-based DES-ATPS are supposed to have the potential to provide new possibilities in the separation of proteins

  13. Rapid response and wide range neutronic power measuring systems for fast pulsed reactors

    International Nuclear Information System (INIS)

    Sumita, Kenji; Iida, Toshiyuki; Wakayama, Naoaki.

    1976-01-01

    This paper summarizes our investigation on design principles of the rapid, stable and wide range neutronic power measuring system for fast pulsed reactors. The picoammeter, the logarithmic amplifier, the reactivity meter and the neutron current chamber are the items of investigation. In order to get a rapid response, the method of compensation for the stray capacitance of the feedback circuits and the capacitance of signal cables is applied to the picoammeter, the logarithmic amplifier and the reactivity meter with consideration for the stability margin of a whole detecting system. The response of an ionization current chamber and the method for compensating the ion component of the chamber output to get optimum responses high pass filters are investigated. Statistical fluctuations of the current chamber output are also considered in those works. The optimum thickness of the surrounding moderator of the neutron detector is also discussed from the viewpoint of the pulse shape deformation and the neutron sensitivity increase. The experimental results are reported, which were observed in the pulse operations of the one shot fast pulsed reactor ''YAYOI'' and the one shot TRIGA ''NSRR'' with the measuring systems using those principles. (auth.)

  14. FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation

    International Nuclear Information System (INIS)

    Pierce, B.F.

    1986-07-01

    The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations

  15. [Effect of a dehydrated extract of nopal (Opuntia ficus indica Mill.) on blood glucose].

    Science.gov (United States)

    Frati-Munari, A C; de León, C; Ariza-Andraca, R; Bañales-Ham, M B; López-Ledesma, R; Lozoya, X

    1989-01-01

    To assess if a dehydrated extract of nopal stems retains the effect on glycemia of the entire nopal stems two experiments were performed. A. Six patients with type II diabetes mellitus in fasting condition received 30 capsules containing 10.1 +/- 0.3 g of the extract, and serum glucose levels were measured hourly from 0 to 180 minutes. B. Six healthy volunteers received 30 capsules with the extract followed by 74 g of dextrose orally. Serum glucose measurements were made in a similar fashion. In each experiment a control test with empty capsules was performed. Nopal extract did not reduce fasting glycemia in diabetic subjects. Nevertheless, the extract diminished the increase of serum glucose which followed a dextrose load. Peak serum glucose was 20.3 +/- 18.2 mg/dl (X +/- SD) lower in the test with nopal than in the control one (P less than 0.025). Dehydrated extract of nopal (Opuntia ficus-indica Mill) did not show acute hypoglycemic effect, although could attenuate postprandial hyperglycemia.

  16. Modulatory effect of Morinda lucida aqueous stem bark extract on ...

    African Journals Online (AJOL)

    Modulatory effect of Morinda lucida aqueous stem bark extract on blood glucose and lipid profile in alloxan-induced diabetic rats. ... 8th day of oral extract treatments while the blood samples for the lipid assays of were obtained directly from heart chambers through cardiac puncture on the 8th day after an overnight fasting.

  17. Development of sputter ion pump based SG leak detection system for Fast Breeder Test Reactor

    International Nuclear Information System (INIS)

    Babu, B.; Sureshkumar, K.V.; Srinivasan, G.

    2013-01-01

    Highlights: ► Development and commissioning of SG leak detection system for FBTR. ► Development of Robust method of using sputter ion pump based system. ► Modifications for improving reliability and availability. ► On line injection of hydrogen in sodium during reactor operation. ► Triplication of the SG leak detection system. - Abstract: The Fast Breeder Test Reactor (FBTR) is a 40 MWt, loop type sodium cooled fast reactor built at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam as a fore-runner to the second stage of Indian nuclear power programme. The reactor design is based on the French reactor Rapsodie with several modifications which include the provision of a steam-water circuit and turbo-generator. FBTR uses sodium as the coolant in the main heat transport medium to transfer heat from the reactor core to the feed water in the tertiary loop for producing superheated steam, which drives the turbo-generator. Sodium and water flow in shell and tube side respectively, separated by thin-walls of the ferritic steel tubes of the once-through steam generator (SG). Material defects in these tubes can lead to leakage of water into sodium, resulting in sodium water reactions leading to undesirable consequences. Early detection of water or steam leaks into sodium in the steam generator units of liquid metal fast breeder reactors (LMFBR) is an important requirement from safety and economic considerations. The SG leak in FBTR is detected by Sputter Ion Pump (SIP) based Steam Generator Leak Detection (SGLD) system and Thermal Conductivity Detector (TCD) based Hydrogen in Argon Detection (HAD) system. Many modifications were carried out in the SGLD system for the reactor operation to improve the reliability and availability. This paper details the development and the acquired experience of SIP based SGLD system instrumentation for real time hydrogen detection in sodium for FBTR.

  18. The extraction system: Eu3+-water-NaCl-HDBM-Benzene

    International Nuclear Information System (INIS)

    Jimenez R, M.; Solache R, M.; Rojas H, A.

    1998-01-01

    It was studied the behavior as in acid as alkaline media of the extraction system with dissolvant integrated by trivalent europium in a 2a sodium chloride media and dibenzoylmethane (HDBM) in benzene at 303 K. It was established: the time in which the balance is reached, the influence of europium hydrolysis, the influence of atmospheric carbon dioxide, the influence of a competitive ligand such as diglycolic acid and the number of HDBM molecules that are consumed by each europium ion during extraction. The europium hydrolysis constants were determined by the potentiometric method, in presence or absence of carbonate ions and with those data distribution diagrams of the europium chemical species were obtained which were present in the aqueous phases of the extraction with dissolvant. (Author)

  19. Extraction Equilibrium of Acrylic Acid by Aqueous Two-Phase Systems Using Hydrophilic Ionic Liquids

    International Nuclear Information System (INIS)

    Lee, Yong Hwa; Lee, Woo Youn; Kim, Ki-Sub; Hong, Yeon Ki

    2014-01-01

    As an effective method for extraction of acrylic acid, aqueous two-phase systems based on morpholinium ionic liquids were used in this study. Effects of the alkyl chain length of cation in morpholinium ionic liquids on phase diagram and extraction efficiencies were investigated. Experimental results show that aqueous two phase systems can be formed by adding appropriate amount of morpholinium ionic liquids to aqueous K 2 HPO 4 solutions. It can be found that the ability of morpholinium ionic liquids for phase separation followed the order [HMMor][Br]>[OMMor][Br]>[BMMor][Br]>[EMMor][Br]. There was little difference between binodal curves of imidazolium ionic liquids and those of morpholinium ionic liquids. 50-90% of the extraction efficiency was observed for acrylic acid by aqueous two phase extraction of acrylic acid with morpholinium ionic liquids. It can be concluded that morpholinium ionic liquids/K 2 HPO 4 were effective for aqueous two phases extraction of acrylic acid comparing to imidazolium ionic liquids/K 2 HPO 4 systems because of their lower cost

  20. Simulations of the TESLA Linear Collider with a Fast Feedback System

    CERN Document Server

    Schulte, Daniel; White, G

    2003-01-01

    The tolerances on the beams as they collide at the interaction point of the TESLA linear collider are very tight due to the nano-metre scale final vertical bunch spot sizes. Ground motion causes the beams to increase in emittance and drift out of collision leading to dramatic degradation of luminosity performance. To combat this, both slow orbit and fast intra-train feedback systems will be used. The design of these feedback systems depends critically on how component misalignment effects the beam throughout the whole accelerator. A simulation has been set up to study in detail the accelerator performance under such conditions by merging the codes of PLACET, MERLIN and GUINEA-PIG together with Simulink code to model feedback systems, all under a Matlab environment.

  1. Preliminary Development of the MARS/FREK Spatial Kinetics Coupled System Code for Square Fueled Fast Reactor Applications

    International Nuclear Information System (INIS)

    Bae, Moo Hoon; Joo, Han Gyu

    2009-01-01

    Incorporation of a three-dimensional (3-D) reactor kinetics model into a system thermal-hydraulic (T/H) code enhances the capability to perform realistic analyses of the core neutronic behavior and the plant system dynamics which are coupled each other. For this advantage, several coupled system T/H and spatial kinetics codes, such as RELAP/PARCS, RELAP5/ PANBOX, and MARS/MASTER have been developed. These codes, however, so far limited to LWR applications. The objective of this work is to develop such a coupled code for fast reactor applications. Particularly, applications to lead-bismuth eutectic (LBE) cooled fast reactor are of interest which employ open square lattices. A fast reactor kinetics code applicable to square fueled cores called FREK is coupled the LBE version of the MARS code. The MARS/MASTER coupled code is used as the reference for the integration. The coupled code MARS/FREK is examined for a conceptual reactor called P-DEMO which is being developed by NUTRECK. In order to check the validity of the coupled code, however, the OECD MSLB benchmark exercise III calculation is solved first

  2. ProbFAST: Probabilistic Functional Analysis System Tool

    Directory of Open Access Journals (Sweden)

    Oliveira Thiago YK

    2010-03-01

    Full Text Available Abstract Background The post-genomic era has brought new challenges regarding the understanding of the organization and function of the human genome. Many of these challenges are centered on the meaning of differential gene regulation under distinct biological conditions and can be performed by analyzing the Multiple Differential Expression (MDE of genes associated with normal and abnormal biological processes. Currently MDE analyses are limited to usual methods of differential expression initially designed for paired analysis. Results We proposed a web platform named ProbFAST for MDE analysis which uses Bayesian inference to identify key genes that are intuitively prioritized by means of probabilities. A simulated study revealed that our method gives a better performance when compared to other approaches and when applied to public expression data, we demonstrated its flexibility to obtain relevant genes biologically associated with normal and abnormal biological processes. Conclusions ProbFAST is a free accessible web-based application that enables MDE analysis on a global scale. It offers an efficient methodological approach for MDE analysis of a set of genes that are turned on and off related to functional information during the evolution of a tumor or tissue differentiation. ProbFAST server can be accessed at http://gdm.fmrp.usp.br/probfast.

  3. ProbFAST: Probabilistic functional analysis system tool.

    Science.gov (United States)

    Silva, Israel T; Vêncio, Ricardo Z N; Oliveira, Thiago Y K; Molfetta, Greice A; Silva, Wilson A

    2010-03-30

    The post-genomic era has brought new challenges regarding the understanding of the organization and function of the human genome. Many of these challenges are centered on the meaning of differential gene regulation under distinct biological conditions and can be performed by analyzing the Multiple Differential Expression (MDE) of genes associated with normal and abnormal biological processes. Currently MDE analyses are limited to usual methods of differential expression initially designed for paired analysis. We proposed a web platform named ProbFAST for MDE analysis which uses Bayesian inference to identify key genes that are intuitively prioritized by means of probabilities. A simulated study revealed that our method gives a better performance when compared to other approaches and when applied to public expression data, we demonstrated its flexibility to obtain relevant genes biologically associated with normal and abnormal biological processes. ProbFAST is a free accessible web-based application that enables MDE analysis on a global scale. It offers an efficient methodological approach for MDE analysis of a set of genes that are turned on and off related to functional information during the evolution of a tumor or tissue differentiation. ProbFAST server can be accessed at http://gdm.fmrp.usp.br/probfast.

  4. Experimental and numerical investigation of the Fast-SAGD process

    Science.gov (United States)

    Shin, Hyundon

    The SAGD process has been tested in the field, and is now in a commercial stage in Western Canadian oil sands areas. The Fast-SAGD method can partly solve the drilling difficulty and reduce costs in a SAGD operation requiring paired parallel wells one above the other. This method also enhances the thermal efficiency in the reservoir. In this research, the reservoir parameters and operating conditions for the SAGD and Fast-SAGD processes are investigated by numerical simulation in the three Alberta oil sands areas. Scaled physical model experiments, which are operated by an automated process control system, are conducted under high temperature and high pressure conditions. The results of the study indicate that the shallow Athabasca-type reservoir, which is thick with high permeability (high kxh), is a good candidate for SAGD application, whereas Cold Lake- and Peace River-type reservoirs, which are thin with low permeability, are not as good candidates for conventional SAGD implementation. The simulation results indicate improved energy efficiency and productivity in most cases for the Fast-SAGD process; in those cases, the project economics were enhanced compared to the SAGD process. Both Cold Lake- and Peace River-type reservoirs are good candidates for a Fast-SAGD application rather than a conventional SAGD application. This new process demonstrates improved efficiency and lower costs for extracting heavy oil from these important reservoirs. A new economic indicator, called simple thermal efficiency parameter (STEP), was developed and validated to evaluate the performance of a SAGD project. STEP is based on cumulative steam-oil ratio (CSOR), calendar day oil rate (CDOR) and recovery factor (RF) for the time prior to the steam-oil ratio (SOR) attaining 4. STEP can be used as a financial metric quantitatively as well as qualitatively for this type of thermal project. An automated process control system was set-up and validated, and has the capability of

  5. Fast analysis of spectral data using neural networks

    International Nuclear Information System (INIS)

    Roach, C.M.

    1992-01-01

    Fast analysis techniques are highly desirable in experiments where measurements are recorded at high rates. In fusion experiments the processing required to obtain plasma parameters is usually orders of magnitude slower than the data acquisition. Spectroscopic diagnostics suffer greatly from this problem. The extraction of plasma parameters from a measured spectrum typically corresponds to a nonlinear mapping between distinct multi-dimensional spaces. Where no analytic expression for the mapping exists, conventional analysis methods (e.g. least squares) are usually iterative and therefore slow. With this concern in mind a fast spectral analysis method involving neural networks has been investigated. (author) 6 refs., 3 figs

  6. Petawatt laser system for fast ignitor studies at ILE, Osaka University

    International Nuclear Information System (INIS)

    Izawa, Y.; Kitagawa, Y.; Fujita, H.

    2003-01-01

    A petawatt laser system has been developed for the fast ignitor studies. Three new technologies were introduced; an optical parametric chirped pulse amplifier (OPCPA) in the front end for suppression of prepulse below 10 -8 the main pulse, a deformable mirror for correction of wave front distortion and the chirped pulse amplification in the GEKKO-XII. The system delivered successfully the output energy of 420 J in 470 fs on target, which corresponds to the focal intensity of more than 10 20 W/cm 2 . By using the PW laser, the heating experiments of the high density plasma imploded by GEKKO-XII started. (author)

  7. Ant-based extraction of rules in simple decision systems over ontological graphs

    Directory of Open Access Journals (Sweden)

    Pancerz Krzysztof

    2015-06-01

    Full Text Available In the paper, the problem of extraction of complex decision rules in simple decision systems over ontological graphs is considered. The extracted rules are consistent with the dominance principle similar to that applied in the dominancebased rough set approach (DRSA. In our study, we propose to use a heuristic algorithm, utilizing the ant-based clustering approach, searching the semantic spaces of concepts presented by means of ontological graphs. Concepts included in the semantic spaces are values of attributes describing objects in simple decision systems

  8. Towards a slow extraction system for the TRIUMF KAON Factory extender ring with 0.1% losses

    International Nuclear Information System (INIS)

    Wienands, U.; Servranckx, R.V.

    1988-06-01

    In order to reduce extraction losses a modified third-integral slow extraction system is proposed using a 0.5 m long and 10 μm thin electrostatic pre-septum. Various factors limiting the extraction efficiency like power-supply noise and synchrotron oscillations are investigated analytically as well as by simulation, and the losses are estimated to be as low as 0.2%. The extracted beam emittance is about 0.2 π mm-mrad. For chromatic extraction a reduction in momentum width of the extracted beam by a factor of 2.5, resulting in an extracted momentum bite of less than 30 MeV/c FWHM, can be achieved without emittance blowup. The duty factor typically is between 55% and 65%. Between 1.8% and 3.7% of the particles did not get extracted by the resonant system. First investigation of half-integer extraction indicates possible difficulties in achieving small extracted emittances. (Author) (5 refs., 4 figs.)

  9. Fast cat-eye effect target recognition based on saliency extraction

    Science.gov (United States)

    Li, Li; Ren, Jianlin; Wang, Xingbin

    2015-09-01

    Background complexity is a main reason that results in false detection in cat-eye target recognition. Human vision has selective attention property which can help search the salient target from complex unknown scenes quickly and precisely. In the paper, we propose a novel cat-eye effect target recognition method named Multi-channel Saliency Processing before Fusion (MSPF). This method combines traditional cat-eye target recognition with the selective characters of visual attention. Furthermore, parallel processing enables it to achieve fast recognition. Experimental results show that the proposed method performs better in accuracy, robustness and speed compared to other methods.

  10. The Effect of Aqueous Root Extract of Watherian Indica on ...

    African Journals Online (AJOL)

    It consists of a well-defined mixture of flavonoids, saponins, sugars, alkaloids and mucilage. Both in vitro and in vivo experiments of the aqueous extract were done. The study to determine the in vivo effect of aqueous root extract of the shrub was on the gastrointestinal transit in conscious rats. In the in vivo experiment, fasted ...

  11. The molecular interactions in the extraction system: acetylacetone-InCl3-water

    International Nuclear Information System (INIS)

    Kulawik, I.; Bogon, E.

    1978-01-01

    The extraction process in the chelate system: acetylacetone-InCl 3 -Water and possibility of the investigations of some physico-chemical properties of this system were discussed. The preliminary measurements for determination the adsorption kinetics and the equilibrium in the system were presented. Also extraction coefficient of indium salt was determined. The results of the principal measurements of the surface and interfacial tension as a function of concentration and temperature in the phases were presented. The measurements were done in different conditions when the both phases were in contact during the same time but in the various temperature. The experimental data served also for the calculation of the work of cohesion and adhesion in the system. The entropy and surface energy of the particular phases of the system were also determined. (author)

  12. Amplification without inversion, fast light and optical bistability in a duplicated two-level system

    International Nuclear Information System (INIS)

    Ebrahimi Zohravi, Lida; Vafafard, Azar; Mahmoudi, Mohammad

    2014-01-01

    The optical properties of a weak probe field in a duplicated two-level system are investigated in multi-photon resonance (MPR) condition and beyond it. It is shown that by changing the relative phase of applied fields, the absorption switches to the amplification without inversion in MPR condition. By applying the Floquet decomposition to the equations of motion beyond MPR condition, it is shown that the phase-dependent behavior is valid only in MPR condition. Moreover, it is demonstrated that the group velocity of light pulse can be controlled by the intensity of the applied fields and the gain-assisted superluminal light propagation (fast light) is obtained in this system. In addition, the optical bistability (OB) behavior of the system is studied beyond MPR condition. We apply an indirect incoherent pumping field to the system and it is found that the group velocity and OB behavior of the system can be controlled by the incoherent pumping rate. - Highlights: • We studied the optical properties of DTL system under MPR condition and beyond it. • By changing the relative phase, the absorption switches to the amplification without inversion in MPR condition. • The gain-assisted superluminal light propagation (fast light) is obtained in this system. • The optical bistability (OB) behavior of the system is studied beyond MPR condition. • The incoherent pumping rate has a major role in controlling the group velocity and OB behavior of the system

  13. Extraction of actinide and lanthanide complexonates in two-phase aqueous system potassium carbonate-polyethylene glycol-water

    International Nuclear Information System (INIS)

    Molochnikova, N.P.; Shkinev, V.M.; Spivakov, B.Ya.; Zolotov, Yu.A.; Myasoedov, B.F.

    1988-01-01

    Extraction system on the basis of polyethylene glycol for the concentration, isolation and separation of actinides is suggested. Extraction of actinides and lanthanides in two-phase aqueous system: potassium carbonate - polyethylene glycol - water in the presence of different complexones is investigated. Trivalent actinides are extracted quantitatively by polyethylene glycol from potassium carbonate solutions in the system with xylenol orange and alizarin-complexone. Under the conditions uranium (6) and plutonium (4) are extracted into the phase, enriched by polyethylene glycol, quite insignificantly, which permits to separate them from trivalent actinides with the separation factor of 10 2 - 10 3 . For actinide and lanthanide separation two complexones were introduced into the system, one of them being extractant, the other one - camouflaging reactant. The best results are obtained for the mixture of xylenol orange and hydroxyethylenediphosphonic acid. Separation coefficients for americium and europium constitute 4.5 - 5.6

  14. Edge plasma diagnostics in the compact helical system (CHS) device using fast neutral lithium beam

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Mario

    1992-05-01

    This paper reports the research activities of the author on using fast neutral lithium beam edge plasma diagnostic, at the Japanese National Institute for Fusion Science compact helical system (CHS). (author). 20 figs.

  15. Fast Batch Production of High-Quality Graphene Films in a Sealed Thermal Molecular Movement System.

    Science.gov (United States)

    Xu, Jianbao; Hu, Junxiong; Li, Qi; Wang, Rubing; Li, Weiwei; Guo, Yufen; Zhu, Yongbo; Liu, Fengkui; Ullah, Zaka; Dong, Guocai; Zeng, Zhongming; Liu, Liwei

    2017-07-01

    Chemical vapor deposition (CVD) growth of high-quality graphene has emerged as the most promising technique in terms of its integrated manufacturing. However, there lacks a controllable growth method for producing high-quality and a large-quantity graphene films, simultaneously, at a fast growth rate, regardless of roll-to-roll (R2R) or batch-to-batch (B2B) methods. Here, a stationary-atmospheric-pressure CVD (SAPCVD) system based on thermal molecular movement, which enables fast B2B growth of continuous and uniform graphene films on tens of stacked Cu(111) foils, with a growth rate of 1.5 µm s -1 , is demonstrated. The monolayer graphene of batch production is found to nucleate from arrays of well-aligned domains, and the films possess few defects and exhibit high carrier mobility up to 6944 cm 2 V -1 s -1 at room temperature. The results indicate that the SAPCVD system combined with single-domain Cu(111) substrates makes it possible to realize fast batch-growth of high-quality graphene films, which opens up enormous opportunities to use this unique 2D material for industrial device applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Fast reactors and nonproliferation

    International Nuclear Information System (INIS)

    Orlov, V.V.

    1997-01-01

    1.Three aspects of nonproliferation relevant to nuclear power are: Pu buildup in NPP spent fuel cooling ponds (∼ 104 t in case of consumption of ∼ 107 t cheap uranium). Danger of illegal radiochemical extraction of Pu for weapons production; Pu extraction from NPP fuel at the plants available in nuclear countries, its burning along with weapon-grade Pu in NPP reactors or in special-purpose burners; increased hazard of nuclear weapons sprawl with breeders and closed fuel cycle technology spreading all over the world. 2.The latter is one of major obstacles to creation of large-scale nuclear power. 3.Nuclear power of the first stage using 235 U will be able to meet the demands of certain fuel-deficient countries and regions, replacing ∼ 5-10% of conventional fuels in the global consumption for a number of decades. 4.Fast reactors of the first generation and the currently employed fuel technology are far from exhausting their potential for solving economic problems and meeting the challenges of safety, radioactive waste and nonproliferation. Development of large-scale nuclear power will become an option accepted by society for solving energy problems in the following century, provided a breeder technology is elaborated and demonstrated in the next 15-20 years, which would comply with the totality of the following requirement: full internal Pu breeding deterministic elimination of severe accidents involving fuel damage and high radioactivity releases: fast runaway, loss of coolant, fires, steam and hydrogen explosions, etc.; reaching a balance between radioactive wastes disposed of and uranium mined in terms of radiation hazard; technology of closed fuel cycle preventing its use for Pu extraction and permitting physical protection from fuel thefts;economic competitiveness of nuclear power for most of countries and regions, i.e. primarily the cost of NPPs with fat reactors is to be below the cost of modern LWR plants, etc

  17. Work extraction and thermodynamics for individual quantum systems

    Science.gov (United States)

    Skrzypczyk, Paul; Short, Anthony J.; Popescu, Sandu

    2014-06-01

    Thermodynamics is traditionally concerned with systems comprised of a large number of particles. Here we present a framework for extending thermodynamics to individual quantum systems, including explicitly a thermal bath and work-storage device (essentially a ‘weight’ that can be raised or lowered). We prove that the second law of thermodynamics holds in our framework, and gives a simple protocol to extract the optimal amount of work from the system, equal to its change in free energy. Our results apply to any quantum system in an arbitrary initial state, in particular including non-equilibrium situations. The optimal protocol is essentially reversible, similar to classical Carnot cycles, and indeed, we show that it can be used to construct a quantum Carnot engine.

  18. Multistage feature extraction for accurate face alignment

    NARCIS (Netherlands)

    Zuo, F.; With, de P.H.N.

    2004-01-01

    We propose a novel multistage facial feature extraction approach using a combination of 'global' and 'local' techniques. At the first stage, we use template matching, based on an Edge-Orientation-Map for fast feature position estimation. Using this result, a statistical framework applying the Active

  19. Radioimmunoassay of extracted glucagon compared with three non-extraction assays

    International Nuclear Information System (INIS)

    Schenck, H. von; Nilsson, O.R.

    1981-01-01

    Radioimmunoassay of glucagon was performed with three different antisera, i.e. E7, 30K and 4305, all directed against the carboxyl-terminal region of glucagon and thus avoiding co-determination of glucagon-like polypeptides from the gut. Plasma samples from five healthy people subjected to various A-cell stimulation and suppression tests were used and immunoreactive glucagon assessed with the three antisera. Aliquots from all plasma samples were also extracted with acetone and glucagon re-assessed with antiserum E7. Even though all four baseline glucagon concentrations obtained were different, the glucagon profiles were comparable after superimposing the baselines. The differences in baseline concentrations of immunoreactive glucagon seem due to the interference of 'big plasma glucagon', a still unidentified factor in the E7 and 30K assays that can be precipitated by acetone. Since acetone extraction yielded the lowest baselines without altering the glucagon profiles, it is suggsted that the baseline glucagon concentrations of acetone-extracted plasma reflect the physiological level of the biologically active hormone. Using antiserum E7, our own antiserum, the normal range of glucagon values in acetone-extracted plasma samples from 22 healthy, fasting people of both sexes was 42+-16 ng/l (mean +- 2 S.D.). These values agree well with those obtained by other assay techniques. (Auth.)

  20. Study on the Extraction and Application of Natural Dyestuff from Onion Skin

    International Nuclear Information System (INIS)

    Nwe Yee Win; Moe Moe Swe

    2010-12-01

    The revival of the use of natural dyes on textiles is due to the increased environmental pollution today. Because of their non-toxic, biodegradable properties and health hazards associated with the synthetic dyes, there is a global interest in natural dyed textiles. This research mainly focuses on the extraction and application of natural dyestuff from onion skin which can be easily collected in Myanmar. The objectives of this study are to extract natural dyestuff from onion skin by studying the effect of dye extraction mediums, to study the optimum dye extraction condition, and to study the fastness properties on dyed sample material. Preliminary phytochemical tests are performed to determine the compounds present in the onion skin. The best dye extraction method is determined by using four types of extraction mediums.Then the determination of dye extraction conditions is investigated by studying the effect of extraction time and solvent ratio on dye yield percent. After that the dye powder extract is applied on cotton fabrics by using different types of fixing agents. Among them, the most suitable type of mordant with onion skin dyestuff is selected for further study. Fastness properties on dyed cotton fabrics such as light, rubbing and washing are carried out. And then the range of colour developed on dyed materials is studied by CIE L*a* b* colour coordinates