WorldWideScience

Sample records for false positive test

  1. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  2. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  3. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  4. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  5. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  6. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  7. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  8. False-positive head-impulse test in cerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Olympia eKremmyda

    2012-11-01

    Full Text Available Abstract:The objective of this study was to compare the findings of the bedside head impulse test (HIT, passive head rotation gain, and caloric irrigation in patients with cerebellar ataxia (CA. In 16 patients with CA and bilaterally pathological bedside HIT, VOR gains were measured during HIT and passive head rotation by scleral search coil technique. Eight of the patients had pathologically reduced caloric responsiveness, while the other eight had normal caloric responses. Those with normal calorics showed a slightly reduced HIT gain (mean±SD: 0.73±0.15. In those with pathological calorics, gains 80ms and 100 ms after the HIT as well as the passive rotation VOR gains were significantly lower. The corrective saccade after head turn occurred earlier in patients with pathological calorics (111±62 ms after onset of the HIT than in those with normal calorics. (191±17 ms, p=0.0064 We indentified two groups of patients with CA: those with an isolated moderate HIT deficit only, probably due to floccular dysfunction, and those with combined HIT, passive rotation and caloric deficit, probably due to a peripheral vestibular deficit. From a clinical point of view, these results show that the bedside HIT alone can be false positive for establishing a diagnosis of a bilateral peripheral vestibular deficit in patients with CA.

  9. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  10. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  11. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  12. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  13. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  14. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  15. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  16. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  17. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  18. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  19. Internal Impingement of the Shoulder: A Risk of False Positive Test Outcomes in External Impingement Tests?

    Directory of Open Access Journals (Sweden)

    Tim Leschinger

    2017-01-01

    Full Text Available Background. External impingement tests are considered as being particularly reliable for identifying subacromial and coracoid shoulder impingement mechanisms. The purpose of the present study was to evaluate if these tests are likely to provoke an internal shoulder impingement mechanism which, in cases of a pathologic condition, can lead to a positive test result. Method. In 37 subjects, the mechanical contact between the glenoid rim and the rotator cuff (RC was measured quantitatively and qualitatively in external impingement test positions using an open MRI system. Results. Mechanical contact of the supraspinatus with the posterosuperior glenoid was present in 30 subjects in the Neer test. In the Hawkins test, the subscapularis was in contact with the anterosuperior glenoid in 33 subjects and the supraspinatus in 18. In the horizontal impingement test, anterosuperior contact of the supraspinatus with the glenoid was identified in 35 subjects. Conclusion. The Neer, Hawkins, and horizontal impingement tests are likely to provoke the mechanism of an internal shoulder impingement. A posterosuperior internal impingement mechanism is being provoked predominately in the Neer test. The Hawkins test narrows the distance between the insertions of the subscapularis and supraspinatus and the anterosuperior labrum, which leads to an anterosuperior impingement mechanism.

  20. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  1. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  2. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  3. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  4. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  5. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    Science.gov (United States)

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  6. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  7. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    Science.gov (United States)

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; phemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; phemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; pHemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  8. ST-Segment Depression in Hyperventilation Indicates a False Positive Exercise Test in Patients with Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Andreas P. Michaelides

    2010-01-01

    Full Text Available Objectives. Mitral valve prolapse (MVP is a known cause for false positive exercise test (ET. The purpose of this study was to establish additional electrocardiographic criteria to distinguish the false positive exercise results in patients with MVP. Methods. We studied 218 consecutive patients ( years, 103 males with MVP (according to echocardiographic study, and positive treadmill ET was performed due to multiple cardiovascular risk factors or angina-like symptoms. A coronary angiography was performed to detect coronary artery disease (CAD. Results. From 218 patients, 90 (group A presented with normal coronary arteries according to the angiography (false positive ET while the rest 128 (group B presented with CAD. ST-segment depression in hyperventilation phase was present in 54 patients of group A (60% while only in 14 patients of group B (11%, . Conclusions. Presence of ST-segment depression in hyperventilation phase favors a false positive ET in patients with MVP.

  9. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  10. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  11. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  12. False-positive pregnancy test after transfusion of solvent/detergent-treated plasma.

    Science.gov (United States)

    Jilma-Stohlawetz, Petra; Wreford-Bush, Tim; Mills, Francesca; Davidson, Fiona; Kursten, Friedrich W; Jilma, Bernd; Birchall, Janet

    2017-12-01

    The transmission of pathogens, antibodies, and proteins is a possible consequence of blood product transfusion. A female patient had an unexpected positive serum β-human chorionic gonadotropin result, indicative of pregnancy, after she had received a transfusion with 1 unit of platelet concentrate, 4 units of red blood cells, and 4 units of pooled solvent/detergent-treated plasma (Octaplas). To investigate the possibility of passive transfusion of β-human chorionic gonadotropin from the plasma transfusion, one additional unit from the same batch was thawed and analyzed. To validate the β-human chorionic gonadotropin assay for use in solvent/detergent-treated plasma and to investigate any interference in the assay, dilution experiments were performed using the implicated plasma batch diluted with male and non-pregnant female sera. Also, plasma from a known pregnant woman was diluted with Octaplas (tested negative for β-human chorionic gonadotropin) and with a male serum to validate the assay for use in solvent/detergent-treated plasma. The implicated solvent/detergent-treated plasma had a mean β-human chorionic gonadotropin level of 91.5 mIU/mL. Results from the dilution experiments revealed an excellent correlation (r > 0.99) between β-human chorionic gonadotropin measurement in solvent/detergent-treated plasma and male serum and no over or under recovery of the expected results. Further measurements of β-human chorionic gonadotropin levels in the female recipient revealed an estimated half-life of 6 hours. This case demonstrates the importance of considering the possibility of passive transmission of analytes to a patient from the transfusion of blood products. Furthermore, the measurement of β-human chorionic gonadotropin is valid in solvent/detergent-treated plasma using a Roche Cobas analyzer. © 2017 AABB.

  13. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  15. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    Science.gov (United States)

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  16. Parental knowledge reduces long term anxiety induced by false-positive test results after newborn screening for cystic fibrosis

    NARCIS (Netherlands)

    Vernooij-van Langen, A.M.M.; Pal, S.M. van der; Reijntjens, A.J.T.; Loeber, J.G.; Dompeling, E.; Dankert-Roelse, J.E.

    2014-01-01

    Background: False-positive screening results in newborn screening for cystic fibrosis may lead to parental stress, family relationship problems and a changed perception of the child's health. Aim of the study: To evaluate whether parental anxiety induced by a false positive screening result

  17. False Positive Stress Testing: Does Endothelial Vascular Dysfunction Contribute to ST-Segment Depression in Women? A Pilot Study.

    Science.gov (United States)

    Sharma, Shilpa; Mehta, Puja K; Arsanjani, Reza; Sedlak, Tara; Hobel, Zachary; Shufelt, Chrisandra; Jones, Erika; Kligfield, Paul; Mortara, David; Laks, Michael; Diniz, Marcio; Bairey Merz, C Noel

    2018-06-19

    The utility of exercise-induced ST-segment depression for diagnosing ischemic heart disease (IHD) in women is unclear. Based on evidence that IHD pathophysiology in women involves coronary vascular dysfunction, we hypothesized that coronary vascular dysfunction contributes to exercise electrocardiography (Ex-ECG) ST-depression in the absence of obstructive CAD, so-called "false positive" results. We tested our hypothesis in a pilot study evaluating the relationship between peripheral vascular endothelial function and Ex-ECG. Twenty-nine asymptomatic women without cardiac risk factors underwent maximal Bruce protocol exercise treadmill testing and peripheral endothelial function assessment using peripheral arterial tonometry (Itamar EndoPAT 2000) to measure reactive hyperemia index (RHI). The relationship between RHI and Ex-ECG ST-segment depression was evaluated using logistic regression and differences in subgroups using two-tailed t-tests. Mean age was 54 ± 7 years, body mass index 25 ± 4 kg/m 2 , and RHI 2.51 ± 0.66. Three women (10%) had RHI less than 1.68, consistent with abnormal peripheral endothelial function, while 18 women (62%) met criteria for a positive Ex-ECG based on ST-segment depression in contiguous leads. Women with and without ST-segment depression had similar baseline and exercise vital signs, metabolic equivalents (METS) achieved, and RHI (all p>0.05). RHI did not predict ST-segment depression. Our pilot study demonstrates a high prevalence of exercise-induced ST-segment depression in asymptomatic, middle-aged, overweight women. Peripheral vascular endothelial dysfunction did not predict Ex-ECG ST-segment depression. Further work is needed to investigate the utility of vascular endothelial testing and Ex-ECG for IHD diagnostic and management purposes in women. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  19. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    Science.gov (United States)

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  20. False Positive and False Negative Effects on Network Attacks

    Science.gov (United States)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  1. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  2. The Lifetime Economic Burden of Inaccurate HER2 Testing: Estimating the Costs of False-Positive and False-Negative HER2 Test Results in US Patients with Early-Stage Breast Cancer.

    Science.gov (United States)

    Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa

    2015-06-01

    Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  4. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  5. An investigation of false positive dosimetry results

    International Nuclear Information System (INIS)

    Lewandowski, M.A.; Davis, S.A.; Goff, T.E.; Wu, C.F.

    1996-01-01

    The Waste Isolation Pilot Plant (WIPP) is a facility designed for the demonstration of the safe disposal of transuranic waste. Currently, the radiation source term is confined to sealed calibration and check sources since WIPP has not received waste for disposal. For several years the WIPP Dosimetry Group has operated a Harshaw Model 8800C reader to analyze Harshaw 8801-7776 thermoluminescent cards (3 TLD-700 and 1 TLD-600) with 8805 holder. The frequency of false positive results for quarterly dosimeter exchanges is higher than desired by the Dosimetry Group management. Initial observations suggested that exposure to intense ambient sunlight may be responsible for the majority of the false positive readings for element 3. A study was designed to investigate the possibility of light leaking through the holder and inducing a signal in element 3. This paper discusses the methods and results obtained, with special emphasis placed on recommendations to reduce the frequency of light-induced false positive readings

  6. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  7. Risk stratification of women with false-positive test results in mammography screening based on mammographic morphology and density

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Lynge, Elsebeth

    2017-01-01

    a case-control study nested in the population-based screening programme in Copenhagen, Denmark. We included 288 cases and 288 controls based on a cohort of 4743 women with at least one FP-test result in 1991–2005 who were followed up until 17 April 2008. Film-based mammograms were assessed using...... the Breast Imaging-Reporting and Data System (BI-RADS) density classification, the Tabár classification, and two automated techniques quantifying percentage mammographic density (PMD) and mammographic texture (MTR), respectively. The association with breast cancer was estimated using binary logistic...

  8. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  9. Detection of Yersinia enterocolitica serotype O:9 in the faeces of cattle with false positive reactions in serological tests for brucellosis in Ireland.

    Science.gov (United States)

    O'Grady, Don; Kenny, Kevin; Power, Seamus; Egan, John; Ryan, Fergus

    2016-10-01

    Intestinal infection by Yersinia enterocolitica serotype O:9 (YeO9) in cattle has been linked to false positive serological reactivity (FPSR) in diagnostic tests for brucellosis. Although eradicated in Ireland, brucellosis monitoring still identifies seropositive animals, usually one or two (termed singletons) per herd, which are classed as FPSR. To investigate a link between FPSR and YeO9, faeces and blood were collected from singleton FPSR cattle, and from companion animals, in eight selected herds with more than one FPSR animal, for YeO9 culture and Brucella serology. YeO9 was isolated from 76/474 (16%) FPSR singletons in 309 herds, but not from any of 621 animals in 122 control non-FPSR herds. In the FPSR herds 52/187 (27.8%) animals were culture positive, and 17% of the isolates were from seronegative animals. Seropositive animals were more likely to have a rising antibody titre when culture positive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  11. Evaluation of false positivity and cross reactivity in the investigation ...

    African Journals Online (AJOL)

    This study evaluated the causes of false positive Human Immunodeficiency Virus test results (F+HIV), cross reactivity of HIV antibodies with other non HIV antibodies, and efficiency of the serial and parallel testing algorithms. 100 blood samples randomly collected from clients attending the Heart to Heart HIV counseling and ...

  12. Small intestinal bacterial overgrowth as an uncommon cause of false positive lactose hydrogen breath test among patients with diarrhea-predominant irritable bowel syndrome in Asia.

    Science.gov (United States)

    Wang, Yilin; Xiong, Lishou; Gong, Xiaorong; Li, Weimin; Zhang, Xiangsong; Chen, Minhu

    2015-06-01

    It has been reported that small intestinal bacterial overgrowth (SIBO) may lead to false positive diagnoses of lactose malabsorption (LM) in irritable bowel syndrome patients. The aim of this study was to determine the influence of SIBO on lactose hydrogen breath test (HBT) results in these patients. Diarrhea-predominant irritable bowel syndrome patients with abnormal lactose HBTs ingested a test meal containing (99m) Tc and lactose. The location of the test meal and the breath levels of hydrogen were recorded simultaneously by scintigraphic scanning and lactose HBT, respectively. The increase in hydrogen concentration was not considered to be caused by SIBO if ≥ 10% of (99m) Tc accumulated in the cecal region at the time or before of abnormal lactose HBT. LM was present in 84% (31/37) of irritable bowel syndrome patients. Twenty of these patients agreed to measurement of oro-cecal transit time. Only three patients (15%) with abnormal lactose HBT might have had SIBO. The median oro-cecal transit time between LM and lactose intolerance patients were 75 min and 45 min, respectively (Z=2.545, P=0.011). Most of irritable bowel syndrome patients with an abnormal lactose HBT had LM. SIBO had little impact on the interpretation of lactose HBTs. The patients with lactose intolerance had faster small intestinal transit than LM patients. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  13. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  14. Characterisation of false-positive observations in botanical surveys

    Directory of Open Access Journals (Sweden)

    Quentin J. Groom

    2017-05-01

    Full Text Available Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify

  15. A Demonstration of Regression False Positive Selection in Data Mining

    Science.gov (United States)

    Pinder, Jonathan P.

    2014-01-01

    Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…

  16. False-positive results in pharmacoepidemiology and pharmacovigilance.

    Science.gov (United States)

    Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine

    2017-09-01

    False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  17. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  18. Interpreting the results of the Semmes-Weinstein monofilament test: accounting for false-positive answers in the international consensus on the diabetic foot protocol by a new model.

    Science.gov (United States)

    Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J

    2014-01-01

    The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Heat treatment and false-positive heartworm antigen testing in ex vivo parasites and dogs naturally infected by Dirofilaria repens and Angiostrongylus vasorum

    Directory of Open Access Journals (Sweden)

    Luigi Venco

    2017-11-01

    Full Text Available Abstract Background Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen–antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min. Results Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites’ antigens that are normally not released into the bloodstream or released in a low amount and/or bound to

  20. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  1. Consequences of a false-positive mammography result

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Bæksted, Christina; Vejborg, Ilse

    2016-01-01

    group used anxiolytic and antidepressant drugs. There was no difference in use of beta blockers. Hormone therapy was used more frequently by the false-positive, 36.6% versus 28.7%. The proportion of women using anxiolytic and antidepressant drugs increased with 19% from the before to the after period...... in the false-positive group, and with 16% in the normal group, resulting in an RRR of 1.02 (95% CI 0.92-1.14). RRR was 1.03 for beta blockers, 0.97 for hormone therapy. Conclusion(s): Drugs used to mitigate mood disorders were used more frequently by women with false-positive than by women with normal......Background: Previous research showed women experiencing false-positive mammograms to have greater anxiety about breast cancer than women with normal mammograms. To elucidate psychological effects of false-positive mammograms, we studied impact on drug intake.  Methods: We calculated the ratio...

  2. Testing jumps via false discovery rate control.

    Science.gov (United States)

    Yen, Yu-Min

    2013-01-01

    Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR), an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS) test statistic, and control the FDR with the Benjamini and Hochberg (BH) procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  3. Testing jumps via false discovery rate control.

    Directory of Open Access Journals (Sweden)

    Yu-Min Yen

    Full Text Available Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR, an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS test statistic, and control the FDR with the Benjamini and Hochberg (BH procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  4. The problem of false positives and false negatives in violent video game experiments.

    Science.gov (United States)

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  6. Epidemiology, public health, and the rhetoric of false positives

    DEFF Research Database (Denmark)

    Blair, Aaron; Saracci, Rodolfo; Vineis, Paolo

    2009-01-01

    BACKGROUND: As an observational science, epidemiology is regarded by some researchers as inherently flawed and open to false results. In a recent paper, Boffetta et al. [Boffetta P, McLaughlin JK, LaVecchia C, Tarone RE, Lipworth L, Blot WJ. False-positive results in cancer epidemiology: a plea f...

  7. False-positive 111In-pentetreotide Uptake in Gastritis

    International Nuclear Information System (INIS)

    Usmani, Sharjeel; Alshammari, Alshaima

    2013-01-01

    111 In-pentetreotide [ 111 In-octreoscan] is the most widely used radiolabeled somatostatin analog for evaluating neuroendocrine tumor overexpression of somatostatin receptors. False-positives studies of somatostatin receptor scintigraphy have been reported and often the cause is unexplained but assumed to be due to high number of somatostatin receptors in other pathologies. Causes of false-positives include visualization of the gallbladder, nasal mucosa and pulmonary hilar areas in respiratory infections, thyroid abnormalities, accessory spleens, recent Cerebrovascular accidents (CVA's) and activity at the site of a recent surgical incision. In infection or inflammation the cause of false-positive uptake is probably the result of tracer binding by somatostatin receptors on the inflammatory leukocytes. In this case report, we report, a 44-year-old male patient with false-positive 111 In-pentetreotide uptake due to gastritis

  8. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  9. Reduction of lymph tissue false positives in pulmonary embolism detection

    Science.gov (United States)

    Ghanem, Bernard; Liang, Jianming; Bi, Jinbo; Salganicoff, Marcos; Krishnan, Arun

    2008-03-01

    Pulmonary embolism (PE) is a serious medical condition, characterized by the partial/complete blockage of an artery within the lungs. We have previously developed a fast yet effective approach for computer aided detection of PE in computed topographic pulmonary angiography (CTPA),1 which is capable of detecting both acute and chronic PEs, achieving a benchmark performance of 78% sensitivity at 4 false positives (FPs) per volume. By reviewing the FPs generated by this system, we found the most dominant type of FP, roughly one third of all FPs, to be lymph/connective tissue. In this paper, we propose a novel approach that specifically aims at reducing this FP type. Our idea is to explicitly exploit the anatomical context configuration of PE and lymph tissue in the lungs: a lymph FP connects to the airway and is located outside the artery, while a true PE should not connect to the airway and must be inside the artery. To realize this idea, given a detected candidate (i.e. a cluster of suspicious voxels), we compute a set of contextual features, including its distance to the airway based on local distance transform and its relative position to the artery based on fast tensor voting and Hessian "vesselness" scores. Our tests on unseen cases show that these features can reduce the lymph FPs by 59%, while improving the overall sensitivity by 3.4%.

  10. Diagnostic Invasiveness and Psychosocial Consequences of False-Positive Mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert Dirk; Brodersen, John

    2015-01-01

    PURPOSE: We undertook a study to assess whether women with false-positivemammography have worse psychosocial consequences if managed with aworkup that involves a biopsy (invasive group) than if managed with only additional imaging (noninvasive group). METHODS: We performed subgroup analysis...... of a cohort study of 454 womenwith abnormal screening mammography and 908 matched control women withnormal results. Using a condition-specific questionnaire (Consequences of Screening in Breast Cancer), we assessed 12 psychosocial consequences at 5 time points (0, 1, 6, 18, and 36 months after final diagnosis......) and compared the 2 groups of women with false-positives (invasive and noninvasive management groups). RESULTS: Among the 252 women with false-positive mammography eligible forthis study, psychosocial consequences were similar for those managed invasivelyand those managed noninvasively during the 36 months...

  11. APHRODITE: an Anomaly-based Architecture for False Positive Reduction

    NARCIS (Netherlands)

    Bolzoni, D.; Etalle, Sandro

    We present APHRODITE, an architecture designed to reduce false positives in network intrusion detection systems. APHRODITE works by detecting anomalies in the output traffic, and by correlating them with the alerts raised by the NIDS working on the input traffic. Benchmarks show a substantial

  12. Detecting false positive sequence homology: a machine learning approach.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  13. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    NARCIS (Netherlands)

    Wolf, M.; Kurvers, R.H.J.M.; Ward, A.J.W.; Krause, S.; Krause, J.

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives;

  14. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  15. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  16. THE XO PLANETARY SURVEY PROJECT: ASTROPHYSICAL FALSE POSITIVES

    International Nuclear Information System (INIS)

    Poleski, Radosaw; McCullough, Peter R.; Valenti, Jeff A.; Burke, Christopher J.; Machalek, Pavel; Janes, Kenneth

    2010-01-01

    Searches for planetary transits find many astrophysical false positives as a by-product. There are four main types analyzed in the literature: a grazing-incidence eclipsing binary (EB) star, an EB star with a small radius companion star, a blend of one or more stars with an unrelated EB star, and a physical triple star system. We present a list of 69 astrophysical false positives that had been identified as candidates of transiting planets of the on-going XO survey. This list may be useful in order to avoid redundant observation and characterization of these particular candidates that have been independently identified by other wide-field searches for transiting planets. The list may be useful for those modeling the yield of the XO survey and surveys similar to it. Subsequent observations of some of the listed stars may improve mass-radius relations, especially for low-mass stars. From the candidates exhibiting eclipses, we report three new spectroscopic double-line binaries and give mass function estimations for 15 single-line spectroscopic binaries.

  17. False positive paediatric labelled white blood cell study

    International Nuclear Information System (INIS)

    Beveridge, N.; Bennett, E.; Thomas, P.

    2002-01-01

    Full text: An eight-month-old female presented for a technetium labelled white blood cell study (LWBC) to exclude an intra-abdominal abscess. Born premature, the child had surgery to repair a perforated bowel and had repeated presentations with diarrhoea, fevers, a tender right upper quadrant and a raised leucocyte count. Multiple imaging modalities failed to demonstrate recurrent bowel perforation, ischaemia or an intra-abdominal mass. A LWBC study was performed with whole body imaging at 1 and 5 hours post re-injection of the radiolabelled blood. No abnormal uptake was visualised in the abdomen but abnormal white cell accumulation was noted in the right hind foot and the length of the right lower leg. This activity appeared to lie along the course of the right tibia. Plain X-ray demonstrated no evidence of tibial osteomyelitis. Concern that the LWBC may be falsely negative in a patient on antibiotics, a gallium scan was immediately performed to re-examine the abdomen. The whole body gallium images demonstrated normal physiological uptake in the abdomen and no evidence of infection in the right leg. The patient had no clinical features to support right leg pathology. The abnormal LWBC localisation in the right lower leg/foot was therefore falsely positive. The most likely explanation is increased activation of the autologous LWBC by 'rough' handling during difficult venesection and re-injection through small veins and needles/cannulas. The slow flow through the veins draining the foot injection site would contribute to margination in these vessel walls. This is a potential cause for false positive LWBC studies- with significant implications for patient care. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. Protein complex prediction via dense subgraphs and false positive analysis.

    Directory of Open Access Journals (Sweden)

    Cecilia Hernandez

    Full Text Available Many proteins work together with others in groups called complexes in order to achieve a specific function. Discovering protein complexes is important for understanding biological processes and predict protein functions in living organisms. Large-scale and throughput techniques have made possible to compile protein-protein interaction networks (PPI networks, which have been used in several computational approaches for detecting protein complexes. Those predictions might guide future biologic experimental research. Some approaches are topology-based, where highly connected proteins are predicted to be complexes; some propose different clustering algorithms using partitioning, overlaps among clusters for networks modeled with unweighted or weighted graphs; and others use density of clusters and information based on protein functionality. However, some schemes still require much processing time or the quality of their results can be improved. Furthermore, most of the results obtained with computational tools are not accompanied by an analysis of false positives. We propose an effective and efficient mining algorithm for discovering highly connected subgraphs, which is our base for defining protein complexes. Our representation is based on transforming the PPI network into a directed acyclic graph that reduces the number of represented edges and the search space for discovering subgraphs. Our approach considers weighted and unweighted PPI networks. We compare our best alternative using PPI networks from Saccharomyces cerevisiae (yeast and Homo sapiens (human with state-of-the-art approaches in terms of clustering, biological metrics and execution times, as well as three gold standards for yeast and two for human. Furthermore, we analyze false positive predicted complexes searching the PDBe (Protein Data Bank in Europe database in order to identify matching protein complexes that have been purified and structurally characterized. Our analysis shows

  19. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    Science.gov (United States)

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  20. The OGCleaner: filtering false-positive homology clusters.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Snell, Quinn; Bybee, Seth M

    2017-01-01

    Detecting homologous sequences in organisms is an essential step in protein structure and function prediction, gene annotation and phylogenetic tree construction. Heuristic methods are often employed for quality control of putative homology clusters. These heuristics, however, usually only apply to pairwise sequence comparison and do not examine clusters as a whole. We present the Orthology Group Cleaner (the OGCleaner), a tool designed for filtering putative orthology groups as homology or non-homology clusters by considering all sequences in a cluster. The OGCleaner relies on high-quality orthologous groups identified in OrthoDB to train machine learning algorithms that are able to distinguish between true-positive and false-positive homology groups. This package aims to improve the quality of phylogenetic tree construction especially in instances of lower-quality transcriptome assemblies. https://github.com/byucsl/ogcleaner CONTACT: sfujimoto@gmail.comSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  1. Risk of breast cancer after false-positive results in mammographic screening

    DEFF Research Database (Denmark)

    Roman, Marta; Castells, Xavier; Hofvind, Solveig

    2016-01-01

    risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50–69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1......Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level.......4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93–2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77–1.96), whereas those who tested false-positive at third screening had a RR...

  2. Comparison of cumulative false-positive risk of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp

    2015-01-01

    INTRODUCTION: In the United States (US), about one-half of women screened with annual mammography have at least one false-positive test after ten screens. The estimate for European women screened ten times biennially is much lower. We evaluate to what extent screening interval, mammogram type......=400,204), between 1991-2012 and 1993-2013, respectively. Model-based cumulative false-positive risks were computed for the entire sample, using two statistical methods (Hubbard Njor) previously used to estimate false-positive risks in the US and Europe. RESULTS: Empirical cumulative risk of at least...... one false-positive test after eight (annual or biennial) screens was 41.9% in BCSC, 16.1% in Copenhagen, and 7.4% in Funen. Variation in screening interval and mammogram type did not explain the differences by country. Using the Hubbard method, the model-based cumulative risks after eight screens...

  3. Risk of breast cancer after false-positive results in mammographic screening.

    Science.gov (United States)

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  4. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  5. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  7. Performance quantification of clustering algorithms for false positive removal in fMRI by ROC curves

    Directory of Open Access Journals (Sweden)

    André Salles Cunha Peres

    Full Text Available Abstract Introduction Functional magnetic resonance imaging (fMRI is a non-invasive technique that allows the detection of specific cerebral functions in humans based on hemodynamic changes. The contrast changes are about 5%, making visual inspection impossible. Thus, statistic strategies are applied to infer which brain region is engaged in a task. However, the traditional methods like general linear model and cross-correlation utilize voxel-wise calculation, introducing a lot of false-positive data. So, in this work we tested post-processing cluster algorithms to diminish the false-positives. Methods In this study, three clustering algorithms (the hierarchical cluster, k-means and self-organizing maps were tested and compared for false-positive removal in the post-processing of cross-correlation analyses. Results Our results showed that the hierarchical cluster presented the best performance to remove the false positives in fMRI, being 2.3 times more accurate than k-means, and 1.9 times more accurate than self-organizing maps. Conclusion The hierarchical cluster presented the best performance in false-positive removal because it uses the inconsistency coefficient threshold, while k-means and self-organizing maps utilize a priori cluster number (centroids and neurons number; thus, the hierarchical cluster avoids clustering scattered voxels, as the inconsistency coefficient threshold allows only the voxels to be clustered that are at a minimum distance to some cluster.

  8. Detection of Biological False Positive Syphilis Serum Reactions ...

    African Journals Online (AJOL)

    A comparative evaluation of reagin tests (Wassermann, VDRL, RPR) and fluorescent treponema antibody absorption tests (FTA-ABS) performed on blood specimens from 5 271 persons (2 493 pregnant women, 1 130 apparently healthy prospective employees, 1 345 newborn babies and 303 leprosy patients) showed that ...

  9. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    Science.gov (United States)

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested

  10. A True-False Test on Methods of Typewriting Instruction.

    Science.gov (United States)

    West, Leonard J.

    1984-01-01

    Presents a true-false test on typewriting instruction to illustrate the effects of educational lag, publishing practices, and deficiencies in preservice and inservice teacher education upon teaching methods. (SK)

  11. [Effects of false memories on the Concealed Information Test].

    Science.gov (United States)

    Zaitsu, Wataru

    2012-10-01

    The effects of false memories on polygraph examinations with the Concealed Information Test (CIT) were investigated by using the Deese-Roediger-McDermott (DRM) paradigm, which allows participants to evoke false memories. Physiological responses to questions consisting of learned, lure, and unlearned items were measured and recorded. The results indicated that responses to lure questions showed critical responses to questions about learned items. These responses included repression of respiration, an increase in electrodermal activity, and a drop in heart rate. These results suggest that critical response patterns are generated in the peripheral nervous system by true and false memories.

  12. False positive seroreactivity to brucellosis in tuberculosis patients: a prevalence study

    Directory of Open Access Journals (Sweden)

    Mojtaba Varshochi

    2011-03-01

    Full Text Available Mojtaba Varshochi1,2, Jafar Majidi2, Marjan Amini1, Kamyar Ghabili3, Mohammadali M Shoja31Department of Infectious Disease, Tabriz University of Medical Sciences, Tabriz, Iran; 2Infectious Disease and Tropical Medicine Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; 3Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: The rising worldwide incidence of tuberculosis (TB increases the demand for knowledge about its potential seroreactivity with other microbial agents. A few reports and the authors’ experiences indicate that tuberculosis may result in a false-positive brucellosis serology. This may cause a diagnostic challenge because of the close clinical resemblance of these two infections.Objective: The aim of the present prevalence study was to elucidate brucellosis seroreactivity in patients with active TB.Methods: Ninety-eight patients with newly diagnosed and active TB were studied using an enzyme-linked immunosorbent assay (ELISA and Wright’s and Coombs–Wright’s tests. Seventy-five healthy individuals were used as controls. The patients showed signs of recovery after starting a standard anti-TB regimen and had no clinical evidence of brucellosis at a subsequent 6-month follow-up. The data were analyzed statistically by Fisher’s exact test using SPSS 11.0.Results: We found that 9.2% of TB patients versus 1.3% of healthy controls had positive results on the anti-Brucella IgG ELISA (P = 0.04. Five TB patients were found to have agglutination on Wright’s tests, while none of the controls showed agglutination.Conclusion: Active TB patients may have some seroreactivity with Brucella antigens, and Brucella IgG ELISA may give a false positive in these patients. Clinicians should consider false positive brucellosis seroreactivity in patients with active TB.Keywords: false positive serology, ELISA, diagnosis

  13. False consensus in situational judgment tests : What would others do?

    NARCIS (Netherlands)

    Oostrom, J.K.; Köbis, N.C.; Ronay, R.; Cremers, M.

    2017-01-01

    We introduce an alternative response instruction to reduce the fakability of situational judgment tests. This novel instruction is based on the false consensus effect, a robust social psychological bias whereby people infer that the majority of other people’s thoughts, attitudes, and behaviors are

  14. Positive events protect children from causal false memories for scripted events.

    Science.gov (United States)

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  15. Memory for media: investigation of false memories for negatively and positively charged public events.

    Science.gov (United States)

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  16. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    Science.gov (United States)

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  17. Look Again: An Investigation of False Positive Detections in Combat Models

    National Research Council Canada - National Science Library

    Wainwright, Ryan K

    2008-01-01

    .... Existing combat models tend to overlook or downplay false positive detections. Signal Detection Theory provides the framework for analysis of an observer's hits, misses, correct rejections, and false alarms...

  18. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    Science.gov (United States)

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  19. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  20. Addressing False Positives in Early Reading Assessment Using Intervention Response Data

    Science.gov (United States)

    McAlenney, Athena Lentini; Coyne, Michael D.

    2015-01-01

    The current study examined a solution to high false positive reading risk classification rates in early kindergarten by investigating a method of identifying students with possible false positive risk classifications and returning them to general classroom instruction. Researchers assessed kindergarten students (N = 105) identified as at risk who…

  1. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  2. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  3. Robust Correlation Analyses: False Positive and Power Validation Using a New Open Source Matlab Toolbox

    Science.gov (United States)

    Pernet, Cyril R.; Wilcox, Rand; Rousselet, Guillaume A.

    2012-01-01

    Pearson’s correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab(R) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand. PMID:23335907

  4. Robust correlation analyses: false positive and power validation using a new open source matlab toolbox.

    Science.gov (United States)

    Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A

    2012-01-01

    Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.

  5. Early Disseminated Lyme Disease Causing False-Positive Serology for Primary Epstein-Barr Virus Infection: Report of 2 Cases.

    Science.gov (United States)

    Pavletic, Adriana J; Marques, Adriana R

    2017-07-15

    False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  7. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  8. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    Science.gov (United States)

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  10. A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

    International Nuclear Information System (INIS)

    Sliski, David H.; Kipping, David M.

    2014-01-01

    Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

  11. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    Science.gov (United States)

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  12. PRE-SPECTROSCOPIC FALSE-POSITIVE ELIMINATION OF KEPLER PLANET CANDIDATES

    International Nuclear Information System (INIS)

    Batalha, Natalie M.; Rowe, Jason F.; Borucki, William J.; Koch, David G.; Lissauer, Jack J.; Gilliland, Ronald L.; Jenkins, Jon J.; Caldwell, Douglas; Dunham, Edward W.; Gautier, Thomas N.; Howell, Steve B.; Latham, David W.; Marcy, Geoff W.; Prsa, Andrej

    2010-01-01

    Ten days of commissioning data (Quarter 0) and 33 days of science data (Quarter 1) yield instrumental flux time series of ∼150,000 stars that were combed for transit events, termed threshold crossing events(TCE), each having a total detection statistic above 7.1σ. TCE light curves are modeled as star+planet systems. Those returning a companion radius smaller than 2R J are assigned a Kepler Object of Interest (KOI) number. The raw flux, pixel flux, and flux-weighted centroids of every KOI are scrutinized to assess the likelihood of being an astrophysical false positive versus the likelihood of being a planetary companion. This vetting using Kepler data is referred to as data validation (DV). Herein, we describe the DV metrics and graphics used to identify viable planet candidates amongst the KOIs. Light curve modeling tests for (1) the difference in depth of the odd- versus even-numbered transits, (2) evidence of ellipsoidal variations, and (3) evidence of a secondary eclipse event at phase = 0.5. Flux-weighted centroids are used to test for signals correlated with transit events with a magnitude and direction indicative of a background eclipsing binary. Centroid time series are complimented by analysis of images taken in-transit versus out-of-transit, the difference often revealing the pixel contributing the most to the flux change during transit. Examples are shown to illustrate each test. Candidates passing DV are submitted to ground-based observers for further false-positive elimination or confirmation/characterization.

  13. Empirical methods for controlling false positives and estimating confidence in ChIP-Seq peaks

    Directory of Open Access Journals (Sweden)

    Courdy Samir J

    2008-12-01

    Full Text Available Abstract Background High throughput signature sequencing holds many promises, one of which is the ready identification of in vivo transcription factor binding sites, histone modifications, changes in chromatin structure and patterns of DNA methylation across entire genomes. In these experiments, chromatin immunoprecipitation is used to enrich for particular DNA sequences of interest and signature sequencing is used to map the regions to the genome (ChIP-Seq. Elucidation of these sites of DNA-protein binding/modification are proving instrumental in reconstructing networks of gene regulation and chromatin remodelling that direct development, response to cellular perturbation, and neoplastic transformation. Results Here we present a package of algorithms and software that makes use of control input data to reduce false positives and estimate confidence in ChIP-Seq peaks. Several different methods were compared using two simulated spike-in datasets. Use of control input data and a normalized difference score were found to more than double the recovery of ChIP-Seq peaks at a 5% false discovery rate (FDR. Moreover, both a binomial p-value/q-value and an empirical FDR were found to predict the true FDR within 2–3 fold and are more reliable estimators of confidence than a global Poisson p-value. These methods were then used to reanalyze Johnson et al.'s neuron-restrictive silencer factor (NRSF ChIP-Seq data without relying on extensive qPCR validated NRSF sites and the presence of NRSF binding motifs for setting thresholds. Conclusion The methods developed and tested here show considerable promise for reducing false positives and estimating confidence in ChIP-Seq data without any prior knowledge of the chIP target. They are part of a larger open source package freely available from http://useq.sourceforge.net/.

  14. Psychological effects of false-positive results in expanded newborn screening in China.

    Directory of Open Access Journals (Sweden)

    Wen-Jun Tu

    Full Text Available OBJECTIVES: As more families participate expanded newborn screening for metabolic disorders in China, the overall number of false positives increases. Our goal was to assess the potential impact on parental stress, perceptions of the child's health, and family relationships. METHODS: Parents of 49 infants with false-positive screening results for metabolic disorders in the expanded newborn screening panel were compared with parents of 42 children with normal screening results. Parents first completed structured interview using likert scales, closed and open questions. Parents also completed the parenting stress index. RESULTS: A total of 88 mothers and 41 fathers were interviewed. More mothers in the false-positive group reported that their children required extra parental care (21%, compared with 5% of mothers in the normal-screened group (P<0.001. 39% of mothers in the false-positive group reported that they worry about their child's future development, compared with 10% of mothers in the normal-screened group (P<0.001. Fathers in the false-positive group did not differ from fathers in the normal-screened group in reporting worry about their child's extra care requirements, and their child's future development. Children with false-positive results compared with children with normal results were triple as likely to experience hospitalization (27%vs 9%, respectively; P<0.001. CONCLUSIONS: The results showing false-positive screening results may affect parental stress and the parent-child relationship. Parental stress and anxiety can be reduced with improved education and communication to parents about false-positive results.

  15. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    Science.gov (United States)

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  17. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    International Nuclear Information System (INIS)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.; Stuzman, R.E.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadal function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men

  18. Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.

    Science.gov (United States)

    Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui

    2018-02-01

    Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  20. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    Science.gov (United States)

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  1. Algorithm of reducing the false positives in IDS based on correlation Analysis

    Science.gov (United States)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  2. Categorizing Mistaken False Positives in Regulation of Human and Environmental Health

    DEFF Research Database (Denmark)

    Hansen, Steffen Foss; Krayer von Krauss, Martin Paul; Tickner, J.A.

    2007-01-01

    One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general......," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only...... four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent...

  3. Image Watermarking Scheme for Specifying False Positive Probability and Bit-pattern Embedding

    Science.gov (United States)

    Sayama, Kohei; Nakamoto, Masayoshi; Muneyasu, Mitsuji; Ohno, Shuichi

    This paper treats a discrete wavelet transform(DWT)-based image watermarking with considering the false positive probability and bit-pattern embedding. We propose an iterative embedding algorithm of watermarking signals which are K sets pseudo-random numbers generated by a secret key. In the detection, K correlations between the watermarked DWT coefficients and watermark signals are computed by using the secret key. L correlations are made available for the judgment of the watermark presence with specified false positive probability, and the other K-L correlations are corresponding to the bit-pattern signal. In the experiment, we show the detection results with specified false positive probability and the bit-pattern recovery, and the comparison of the proposed method against JPEG compression, scaling down and cropping.

  4. The effects of initial testing on false recall and false recognition in the social contagion of memory paradigm.

    Science.gov (United States)

    Huff, Mark J; Davis, Sara D; Meade, Michelle L

    2013-08-01

    In three experiments, participants studied photographs of common household scenes. Following study, participants completed a category-cued recall test without feedback (Exps. 1 and 3), a category-cued recall test with feedback (Exp. 2), or a filler task (no-test condition). Participants then viewed recall tests from fictitious previous participants that contained erroneous items presented either one or four times, and then completed final recall and source recognition tests. The participants in all conditions reported incorrect items during final testing (a social contagion effect), and across experiments, initial testing had no impact on false recall of erroneous items. However, on the final source-monitoring recognition test, initial testing had a protective effect against false source recognition: Participants who were initially tested with and without feedback on category-cued initial tests attributed fewer incorrect items to the original event on the final source-monitoring recognition test than did participants who were not initially tested. These data demonstrate that initial testing may protect individuals' memories from erroneous suggestions.

  5. Newly formed skeletal muscle fibers are prone to false positive immunostaining by rabbit antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Kliem, Anette; Schrøder, Henrik Daa

    2011-01-01

    rely on controls that reveal non-specific binding by the secondary antibody and neglect that the primary rabbit antibody itself may cause false positive staining of the muscle. We suggest that reliable immuno-based protein detection in newly formed muscle fibers at least requires a nonsense rabbit......Reports on muscle biology and regeneration often implicate immuno(cyto/histo)chemical protein characterization using rabbit polyclonal antibodies. In this study we demonstrate that newly formed myofibers are especially prone to false positive staining by rabbit antibodies and this unwanted staining...

  6. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. False positive results using calcitonin as a screening method for medullary thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Rafael Loch Batista

    2013-01-01

    Full Text Available The role of serum calcitonin as part of the evaluation of thyroid nodules has been widely discussed in literature. However there still is no consensus of measurement of calcitonin in the initial evaluation of a patient with thyroid nodule. Problems concerning cost-benefit, lab methods, false positive and low prevalence of medullary thyroid carcinoma (MTC are factors that limit this approach. We have illustrated two cases where serum calcitonin was used in the evaluation of thyroid nodule and rates proved to be high. A stimulation test was performed, using calcium as secretagogue, and calcitonin hyper-stimulation was confirmed, but anatomopathologic examination did not evidence medullar neoplasia. Anatomopathologic diagnosis detected Hashimoto thyroiditis in one case and adenomatous goiter plus an occult papillary thyroid carcinoma in the other one. Recommendation for routine use of serum calcitonin in the initial diagnostic evaluation of a thyroid nodule, followed by a confirming stimulation test if basal serum calcitonin is showed to be high, is the most currently recommended approach, but questions concerning cost-benefit and possibility of diagnosis error make the validity of this recommendation discussible.

  8. THE POSSIBLE MOON OF KEPLER-90g IS A FALSE POSITIVE

    Energy Technology Data Exchange (ETDEWEB)

    Kipping, D. M.; Torres, G.; Buchhave, L. A. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Huang, X.; Bakos, G. Á. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 05844 (United States); Nesvorný, D. [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States); Schmitt, A. R., E-mail: dkipping@cfa.harvard.edu

    2015-01-20

    The discovery of an exomoon would provide deep insights into planet formation and the habitability of planetary systems, with transiting examples being particularly sought after. Of the hundreds of Kepler planets now discovered, the seven-planet system Kepler-90 is unusual for exhibiting an unidentified transit-like signal in close proximity to one of the transits of the long-period gas-giant Kepler-90g, as noted by Cabrera et al. As part of the ''Hunt for Exomoons with Kepler'' project, we investigate this possible exomoon signal and find it passes all conventional photometric, dynamical, and centroid diagnostic tests. However, pixel-level light curves indicate that the moon-like signal occurs on nearly all of the target's pixels, which we confirm using a novel way of examining pixel-level data which we dub the ''transit centroid''. This test reveals that the possible exomoon to Kepler-90g is likely a false positive, perhaps due to a cosmic ray induced sudden pixel sensitivity dropout. This work highlights the extreme care required for seeking non-periodic low-amplitude transit signals, such as exomoons.

  9. Testing a flexible method to reduce false monsoon onsets.

    Directory of Open Access Journals (Sweden)

    Mathew Alexander Stiller-Reeve

    Full Text Available To generate information about the monsoon onset and withdrawal we have to choose a monsoon definition and apply it to data. One problem that arises is that false monsoon onsets can hamper our analysis, which is often alleviated by smoothing the data in time or space. Another problem is that local communities or stakeholder groups may define the monsoon differently. We therefore aim to develop a technique that reduces false onsets for high-resolution gridded data, while also being flexible for different requirements that can be tailored to particular end-users. In this study, we explain how we developed our technique and demonstrate how it successfully reduces false onsets and withdrawals. The presented results yield improved information about the monsoon length and its interannual variability. Due to this improvement, we are able to extract information from higher resolution data sets. This implies that we can potentially get a more detailed picture of local climate variations that can be used in more local climate application projects such as community-based adaptations.

  10. The false sero-negativity of brucella standard agglutination test: Prozone phenomenon

    Directory of Open Access Journals (Sweden)

    İrfan Binici

    2011-12-01

    Full Text Available Objectives: We aimed to assess prozone phenomenon that is quite rare and causes false negativity in serological diagnosisof brucellosis with standard dilution titers.Materials and methods: In this study the tests of four cases that have false negative serological results were evaluated.Blood cultures were obtained from all cases while cerebrospinal fluid cultures were studied in the two cases. Standardagglutination test (SAT and Coombs test were performed to all patients.Results: SAT and Coombs test was negative in titers up to 1/640 in all cases. The SAT and Coombs tests in cerebrospinalfluid (CSF of the two cases with neurobrucellosis diagnosis were negative, as well. Since the clinical and laboratoryfindings suggested the brucellosis, the serums were restudied by diluting up to 1/10240 titer and we saw that the first3 cases became positive at a titer of 1/1280. The fourth case remained negative and therefore, we applied high dilutionCoombs test. This time the test gave a positive result at 1/10240 titer beginning from 1/2560 titer. B.melitensis wasisolated from two cases.Conclusion: SAT and Coombs’ test must be diluted to titers 1/2560 or more in order to exclude false sero-negativity incases with clinical and laboratory findings suggesting brucellosis. J Microbiol Infect Dis 2011; 1(3:110-113

  11. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  12. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  13. IS HCI THAT IS USED AS A PRESERVATIVE CREATING FALSE POSITIVES FOR TBA IN GROUND WATER

    Science.gov (United States)

    Will hydrochloric acid produce false positives for TBA? Yes, if you heat the sample to get a lower detection limit for TBA. Conventional purge and trap methods at ambient temperature have a reporting limit for TBA between 50 and 100 g/liter. This is higher than the provisiona...

  14. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  15. False Positive Radioiodinated Metaiodobenzylguanidine (123I-MIBG Uptake in Undifferentiated Adrenal Malignant Tumor

    Directory of Open Access Journals (Sweden)

    Hee Soo Jung

    2015-01-01

    Full Text Available 123I-Metaiodobenzylguanidine (123I-MIBG scintigraphy is a widely used functional imaging tool with a high degree of sensitivity and specificity in diagnosis of pheochromocytoma. However, rare cases of false positive reactions have been reported. A 67-year-old male patient was admitted with epigastric pain. Abdominal computed tomography (CT revealed a heterogeneous left adrenal mass 6 cm in diameter; following hormone testing, 123I-MIBG scintigraphy was performed to determine the presence of pheochromocytoma, which confirmed eccentric uptake by a large left adrenal gland mass. Chest CT and PET-CT confirmed metastatic lymphadenopathy; therefore, endobronchial ultrasound transbronchial needle aspiration was performed. Metastatic carcinoma of unknown origin was suspected from a lymph node biopsy, and surgical resection was performed for definitive diagnosis and correction of excess hormonal secretion. A final diagnosis of undifferentiated adrenal malignant tumor was rendered, instead of histologically malignant pheochromocytoma, despite the uptake of 123I-MIBG demonstrated by scintigraphy.

  16. Detecting and avoiding likely false-positive findings - a practical guide.

    Science.gov (United States)

    Forstmeier, Wolfgang; Wagenmakers, Eric-Jan; Parker, Timothy H

    2017-11-01

    Recently there has been a growing concern that many published research findings do not hold up in attempts to replicate them. We argue that this problem may originate from a culture of 'you can publish if you found a significant effect'. This culture creates a systematic bias against the null hypothesis which renders meta-analyses questionable and may even lead to a situation where hypotheses become difficult to falsify. In order to pinpoint the sources of error and possible solutions, we review current scientific practices with regard to their effect on the probability of drawing a false-positive conclusion. We explain why the proportion of published false-positive findings is expected to increase with (i) decreasing sample size, (ii) increasing pursuit of novelty, (iii) various forms of multiple testing and researcher flexibility, and (iv) incorrect P-values, especially due to unaccounted pseudoreplication, i.e. the non-independence of data points (clustered data). We provide examples showing how statistical pitfalls and psychological traps lead to conclusions that are biased and unreliable, and we show how these mistakes can be avoided. Ultimately, we hope to contribute to a culture of 'you can publish if your study is rigorous'. To this end, we highlight promising strategies towards making science more objective. Specifically, we enthusiastically encourage scientists to preregister their studies (including a priori hypotheses and complete analysis plans), to blind observers to treatment groups during data collection and analysis, and unconditionally to report all results. Also, we advocate reallocating some efforts away from seeking novelty and discovery and towards replicating important research findings of one's own and of others for the benefit of the scientific community as a whole. We believe these efforts will be aided by a shift in evaluation criteria away from the current system which values metrics of 'impact' almost exclusively and towards a system

  17. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    Science.gov (United States)

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  18. False positive reduction in protein-protein interaction predictions using gene ontology annotations

    Directory of Open Access Journals (Sweden)

    Lin Yen-Han

    2007-07-01

    Full Text Available Abstract Background Many crucial cellular operations such as metabolism, signalling, and regulations are based on protein-protein interactions. However, the lack of robust protein-protein interaction information is a challenge. One reason for the lack of solid protein-protein interaction information is poor agreement between experimental findings and computational sets that, in turn, comes from huge false positive predictions in computational approaches. Reduction of false positive predictions and enhancing true positive fraction of computationally predicted protein-protein interaction datasets based on highly confident experimental results has not been adequately investigated. Results Gene Ontology (GO annotations were used to reduce false positive protein-protein interactions (PPI pairs resulting from computational predictions. Using experimentally obtained PPI pairs as a training dataset, eight top-ranking keywords were extracted from GO molecular function annotations. The sensitivity of these keywords is 64.21% in the yeast experimental dataset and 80.83% in the worm experimental dataset. The specificities, a measure of recovery power, of these keywords applied to four predicted PPI datasets for each studied organisms, are 48.32% and 46.49% (by average of four datasets in yeast and worm, respectively. Based on eight top-ranking keywords and co-localization of interacting proteins a set of two knowledge rules were deduced and applied to remove false positive protein pairs. The 'strength', a measure of improvement provided by the rules was defined based on the signal-to-noise ratio and implemented to measure the applicability of knowledge rules applying to the predicted PPI datasets. Depending on the employed PPI-predicting methods, the strength varies between two and ten-fold of randomly removing protein pairs from the datasets. Conclusion Gene Ontology annotations along with the deduced knowledge rules could be implemented to partially

  19. Waiting time and the psychosocial consequences of false-positive mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert; Brodersen, John

    2015-01-01

    Background: There is wide variation in the psychosocial response to false-positive mammography. We aimed to assess whether women having to wait longer to exclude cancer had increased psychosocial consequences that persisted after cancer was ruled out. Findings: We selected women with false......-positive mammography (n = 272), screened for breast cancer in Copenhagen and Funen (Denmark) over a 1-year period. We measured psychosocial consequences immediately before women attended their recall visit and 1, 6, 18 and 36 months after women received their final diagnosis. After women were told that cancer had been...... ruled out, adverse psychosocial consequences decreased with time. We found no statistically significant differences between women who had cancer ruled out immediately at the recall visit (waiting time of 0) and women who had to wait longer before cancer was ruled out (waiting times 1-30, 30...

  20. Conceptual fluency at test shifts recognition response bias in Alzheimer's disease: implications for increased false recognition.

    Science.gov (United States)

    Gold, Carl A; Marchant, Natalie L; Koutstaal, Wilma; Schacter, Daniel L; Budson, Andrew E

    2007-09-20

    The presence or absence of conceptual information in pictorial stimuli may explain the mixed findings of previous studies of false recognition in patients with mild Alzheimer's disease (AD). To test this hypothesis, 48 patients with AD were compared to 48 healthy older adults on a recognition task first described by Koutstaal et al. [Koutstaal, W., Reddy, C., Jackson, E. M., Prince, S., Cendan, D. L., & Schacter D. L. (2003). False recognition of abstract versus common objects in older and younger adults: Testing the semantic categorization account. Journal of Experimental Psychology: Learning, Memory, and Cognition, 29, 499-510]. Participants studied and were tested on their memory for categorized ambiguous pictures of common objects. The presence of conceptual information at study and/or test was manipulated by providing or withholding disambiguating semantic labels. Analyses focused on testing two competing theories. The semantic encoding hypothesis, which posits that the inter-item perceptual details are not encoded by AD patients when conceptual information is present in the stimuli, was not supported by the findings. In contrast, the conceptual fluency hypothesis was supported. Enhanced conceptual fluency at test dramatically shifted AD patients to a more liberal response bias, raising their false recognition. These results suggest that patients with AD rely on the fluency of test items in making recognition memory decisions. We speculate that AD patients' over reliance upon fluency may be attributable to (1) dysfunction of the hippocampus, disrupting recollection, and/or (2) dysfunction of prefrontal cortex, disrupting post-retrieval processes.

  1. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  2. Cross-reactive Carbohydrate Determinant Contributes to the False Positive IgE Antibody to Peanut

    Directory of Open Access Journals (Sweden)

    Komei Ito

    2005-01-01

    Conclusions: Social education about the features of peanut allergy is needed in Japan. Anti-CCD IgE antibody was suggested to be one of the mechanisms contributing to the false positive detection of peanut IgE. Detection of anti-HRP or anti-bromelain IgE can be a useful tool to recognize the presence of anti-CCD antibodies.

  3. Shape based automated detection of pulmonary nodules with surface feature based false positive reduction

    International Nuclear Information System (INIS)

    Nomura, Y.; Itoh, H.; Masutani, Y.; Ohtomo, K.; Maeda, E.; Yoshikawa, T.; Hayashi, N.

    2007-01-01

    We proposed a shape based automated detection of pulmonary nodules with surface feature based false positive (FP) reduction. In the proposed system, the FP existing in internal of vessel bifurcation is removed using extracted surface of vessels and nodules. From the validation with 16 chest CT scans, we find that the proposed CAD system achieves 18.7 FPs/scan at 90% sensitivity, and 7.8 FPs/scan at 80% sensitivity. (orig.)

  4. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  5. Bloodstains on Leather: Examination of False Negatives in Presumptive Test and Human Hemoglobin Test.

    Science.gov (United States)

    Castelló, Ana; Francès, Francesc; Verdú, Fernando

    2017-09-01

    Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.

  6. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  7. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  8. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  9. Proteins interacting with cloning scars: a source of false positive protein-protein interactions.

    Science.gov (United States)

    Banks, Charles A S; Boanca, Gina; Lee, Zachary T; Florens, Laurence; Washburn, Michael P

    2015-02-23

    A common approach for exploring the interactome, the network of protein-protein interactions in cells, uses a commercially available ORF library to express affinity tagged bait proteins; these can be expressed in cells and endogenous cellular proteins that copurify with the bait can be identified as putative interacting proteins using mass spectrometry. Control experiments can be used to limit false-positive results, but in many cases, there are still a surprising number of prey proteins that appear to copurify specifically with the bait. Here, we have identified one source of false-positive interactions in such studies. We have found that a combination of: 1) the variable sequence of the C-terminus of the bait with 2) a C-terminal valine "cloning scar" present in a commercially available ORF library, can in some cases create a peptide motif that results in the aberrant co-purification of endogenous cellular proteins. Control experiments may not identify false positives resulting from such artificial motifs, as aberrant binding depends on sequences that vary from one bait to another. It is possible that such cryptic protein binding might occur in other systems using affinity tagged proteins; this study highlights the importance of conducting careful follow-up studies where novel protein-protein interactions are suspected.

  10. Analyzing false positives of four questions in the Force Concept Inventory

    Science.gov (United States)

    Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-06-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.

  11. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  12. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  13. False-Positive Rate Determination of Protein Target Discovery using a Covalent Modification- and Mass Spectrometry-Based Proteomics Platform

    Science.gov (United States)

    Strickland, Erin C.; Geer, M. Ariel; Hong, Jiyong; Fitzgerald, Michael C.

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2 % and analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  14. Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model

    International Nuclear Information System (INIS)

    Ayres, Fabio J.; Rangayyan, Rangaraj M.

    2007-01-01

    Objective One of the commonly missed signs of breast cancer is architectural distortion. We have developed techniques for the detection of architectural distortion in mammograms, based on the analysis of oriented texture through the application of Gabor filters and a linear phase portrait model. In this paper, we propose constraining the shape of the general phase portrait model as a means to reduce the false-positive rate in the detection of architectural distortion. Material and methods The methods were tested with one set of 19 cases of architectural distortion and 41 normal mammograms, and with another set of 37 cases of architectural distortion. Results Sensitivity rates of 84% with 4.5 false positives per image and 81% with 10 false positives per image were obtained for the two sets of images. Conclusion The adoption of a constrained phase portrait model with a symmetric matrix and the incorporation of its condition number in the analysis resulted in a reduction in the false-positive rate in the detection of architectural distortion. The proposed techniques, dedicated for the detection and localization of architectural distortion, should lead to efficient detection of early signs of breast cancer. (orig.)

  15. Prenatal ultrasound screening: false positive soft markers may alter maternal representations and mother-infant interaction.

    Directory of Open Access Journals (Sweden)

    Sylvie Viaux-Savelon

    Full Text Available In up to 5% of pregnancies, ultrasound screening detects a "soft marker" (SM that places the foetus at risk for a severe abnormality. In most cases, prenatal diagnostic work-up rules out a severe defect. We aimed to study the effects of false positive SM on maternal emotional status, maternal representations of the infant, and mother-infant interaction.Utilizing an extreme-case prospective case control design, we selected from a group of 244 women undergoing ultrasound, 19 pregnant women whose foetus had a positive SM screening and a reassuring diagnostic work up, and 19 controls without SM matched for age and education. In the third trimester of pregnancy, within one week after delivery, and 2 months postpartum, we assessed anxiety, depression, and maternal representations. Mother-infant interactions were videotaped during feeding within one week after delivery and again at 2 months postpartum and coded blindly using the Coding Interactive Behavior (CIB scales. Anxiety and depression scores were significantly higher at all assessment points in the SM group. Maternal representations were also different between SM and control groups at all study time. Perturbations to early mother-infant interactions were observed in the SM group. These dyads showed greater dysregulation, lower maternal sensitivity, higher maternal intrusive behaviour and higher infant avoidance. Multivariate analysis showed that maternal representation and depression at third trimester predicted mother-infant interaction.False positive ultrasound screenings for SM are not benign and negatively affect the developing maternal-infant attachment. Medical efforts should be directed to minimize as much as possible such false diagnoses, and to limit their psychological adverse consequences.

  16. Suture Granuloma Showing False-Positive Findings on FDG-PET

    Directory of Open Access Journals (Sweden)

    Kohei Takahara

    2013-01-01

    Full Text Available We report a case of a 33-year-old male with a mixed germ-cell testicular tumor. Postoperative follow-up FDG-PET revealed concentration of FDG in the left inguinal area which is not tumor metastasis or local recurrence but suture reactivity granuloma. In this paper, we reviewed suture granulomas associated with false-positive findings on FDG-PET after surgery. If FDG-PET will be used more frequently in the future, it will be necessary to refrain from using silk thread in order to prevent any unnecessary surgery.

  17. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  18. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  19. Way forward in case of a false positive in vitro genotoxicity result for a cosmetic substance?

    Science.gov (United States)

    Doktorova, Tatyana Y; Ates, Gamze; Vinken, Mathieu; Vanhaecke, Tamara; Rogiers, Vera

    2014-02-01

    The currently used regulatory in vitro mutagenicity/genotoxicity test battery has a high sensitivity for detecting genotoxicants, but it suffers from a large number of irrelevant positive results (i.e. low specificity) thereby imposing the need for additional follow-up by in vitro and/or in vivo genotoxicity tests. This could have a major impact on the cosmetic industry in Europe, seen the imposed animal testing and marketing bans on cosmetics and their ingredients. Afflicted, but safe substances could therefore be lost. Using the example of triclosan, a cosmetic preservative, we describe here the potential applicability of a human toxicogenomics-based in vitro assay as a potential mechanistically based follow-up test for positive in vitro genotoxicity results. Triclosan shows a positive in vitro chromosomal aberration test, but is negative during in vivo follow-up tests. Toxicogenomics analysis unequivocally shows that triclosan is identified as a compound acting through non-DNA reactive mechanisms. This proof-of-principle study illustrates the potential of genome-wide transcriptomics data in combination with in vitro experimentation as a possible weight-of-evidence follow-up approach for de-risking a positive outcome in a standard mutagenicity/genotoxicity battery. As such a substantial number of cosmetic compounds wrongly identified as genotoxicants could be saved for the future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. PIPIDA scintigraphy for cholecystitis: false positives in alcoholism and total parenteral nutrition

    International Nuclear Information System (INIS)

    Shuman, W.P.; Gibbs, P.; Rudd, T.G.; Mack, L.A.

    1982-01-01

    A review of gallbladder scintigraphy in patients with potentially compromised hepatobiliary function revealed two groups in whom cholecystitis might be mistakenly diagnosed. In 200 consecutive hospitalized patients studied with technetium-99m-PIPIDA for acute cholecystitis or cholestasis, there were 41 alcoholics and 17 patients on total parenteral nutrition. In 60% of the alcoholics and 92% of those on parenteral nutrition, absent or delayed visualization of the gallbladder occurred without physical or clinical evidence of cholecystitis. A cholecystagogue, sincalide, did not prevent the false-positive features which presumably are due to altered bile flow kinetics related to alcoholism and parenteral nutrition. Four patients on parenteral nutrition undergoing cholecystectomy for suspected cholecystitis had normal gallbladders filled with jellylike viscous thick bile. A positive (nonvisualized or delayed visualized) gallbladder PIPIDA scintigram in these two populations should not be interpreted as indicating a need for cholecystectomy

  1. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  2. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  3. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  4. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  5. False-negative reactions to the comparative intradermal tuberculin test for bovine tuberculosis

    Directory of Open Access Journals (Sweden)

    Rudielle A. Rodrigues

    Full Text Available ABSTRACT: According to the Brazilian National Program for the Control and Eradication of Animal Brucellosis and Tuberculosis (PNCEBT, the routine tests for the diagnosis of bovine tuberculosis in the country are the simple intradermal tuberculin test (SITT of the Ministry of Agriculture, Livestock and Food Supply (MAPA, the caudal fold test and the comparative intradermal tuberculin test (CITT. The latter is also used as a confirmatory test. A group of 53 animals from three dairy herds in a focal area for bovine tuberculosis, that were submitted to depopulation in the state of Rio Grande do Sul, were submitted to the CITT. Tissues were cultured and the resulting colonies were confirmed by PCR and DNA sequencing. Among the 53 animals analyzed using the CITT, 32 (60.4% were negative, 14 (26.4% were positive and seven (13.2% results were inconclusive. The CITT detected 11 of the 39 animals with culture-confirmed M. bovis infection as positive. Among the total of 14 uninfected animals based on cultures, the CBT detected eight as negative. Thus, the CITT demonstrated sensitivity of 28.2% and specificity of 57.1% for the population sampled. A total of 24/32 (75.0% of the animals with negative CITT results were culture positive (confirmed by PCR and were considered false negatives based on the CITT. The maintenance of these false-negative animals in herds has serious implications for the control of the disease, since they can be a source of infection. The addition of complementary tests could help identify such animals and increase the odds of diagnostic success.

  6. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Directory of Open Access Journals (Sweden)

    Yamaguchi Rin

    2012-05-01

    Full Text Available Abstract Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases, to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6% cases were benign, including mastopathy (fibrocystic disease in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9% cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC being significantly more frequent (49.5% than papillotubular growing type (Papi-tub (P P = 0.0001 and ductal carcinoma in situ (DCIS (P = 0.0001. Among 458 indeterminate cases, 54/139 (38.8% were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0% and 73/139 (52.5% were malignant, with SIDC being the most frequent malignant tumor (37.0%. Among 52 false-negative cases, SIDC was significantly more frequent (42.3% than DCIS (P = 0.0049 and Papi-tub (P = 0.001. There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for

  7. Occurrence of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae isolates.

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Adequate detection of the production of carbapenemase in Enterobacteriaceae isolates is crucial for infection control measures and the appropriate choice of antimicrobial therapy. In this study, we investigated the frequency of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae clinical isolates by the modified Hodge test (MHT. Three hundred and one E. coli and K. pneumoniae clinical isolates were investigated. All produced extended spectrum β-lactamases (ESBLs but were susceptible to carbapenems. Antimicrobial susceptibility testing was performed by the disk diffusion and agar dilution methods. The MHT was performed using the standard inoculum of test organisms recommended by the CLSI. Genes that encoded ESBLs and carbapenemases were identified by PCR and DNA sequencing. Among the 301 clinical isolates, none of the isolates conformed to the criteria for carbapenemase screening recommended by the CLSI. The susceptibility rates for imipenem, meropenem, and ertapenem all were 100.0%, 100.0%, and 100.0%, respectively. Of the 301 E. coli and K. pneumoniae isolates, none produced carbapenemase. The MHT gave a positive result for 3.3% (10/301 of the isolates. False positive results can occur when the MHT is used to detect carbapenemase in ESBL-producing isolates and clinical laboratories must be aware of this fact.

  8. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    Science.gov (United States)

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  9. Improved accuracy of cell surface shaving proteomics in Staphylococcus aureus using a false-positive control

    DEFF Research Database (Denmark)

    Solis, Nestor; Larsen, Martin Røssel; Cordwell, Stuart J

    2010-01-01

    Proteolytic treatment of intact bacterial cells is an ideal means for identifying surface-exposed peptide epitopes and has potential for the discovery of novel vaccine targets. Cell stability during such treatment, however, may become compromised and result in the release of intracellular proteins...... that complicate the final analysis. Staphylococcus aureus is a major human pathogen, causing community and hospital-acquired infections, and is a serious healthcare concern due to the increasing prevalence of multiple antibiotic resistances amongst clinical isolates. We employed a cell surface "shaving" technique...... to trypsin and three identified in the control. The use of a subtracted false-positive strategy improved enrichment of surface-exposed peptides in the trypsin data set to approximately 80% (124/155 peptides). Predominant surface proteins were those associated with methicillin resistance-surface protein SACOL...

  10. Factors associated with false-positive self-reported adherence to antihypertensive drugs.

    Science.gov (United States)

    Tedla, Y G; Bautista, L E

    2017-05-01

    Self-reported medication adherence is known to overestimate true adherence. However, little is known about patient factors that may contribute to the upward bias in self-reported medication adherence. The objective of this study is to examine whether demographic, behavioral, medication and mood factors are associated with being a false-positive self-reported adherer (FPA) to antihypertensive drug treatment. We studied 175 patients (mean age: 50 years; 57% men) from primary-care clinics starting antihypertensive drug treatment. Self-reported adherence (SRA) was measured with the Medication Adherence Report Scale (MARS) and by the number of drug doses missed in the previous week/month, and compared with pill count adherence ratio (PCAR) as gold standard. Data on adherence, demographic, behavioral, medication and mood factors were collected at baseline and every 3 months up to 1 year. FPA was defined as being a non-adherer by PCAR and an adherer by self-report. Mixed effect logistic regression was used for the analysis. Twenty percent of participants were FPA. Anxiety increased (odds ratio (OR): 3.00; P=0.01), whereas smoking (OR: 0.40; P=0.03) and drug side effects (OR: 0.46, P=0.03) decreased the probability for FPA by MARS. Education below high-school completion increased the probability of being an FPA as measured by missing doses in the last month (OR: 1.66; P=0.04) and last week (OR: 1.88; P=0.02). The validity of SRA varies significantly according to drug side effects, behavioral factors and patient's mood. Careful consideration should be given to the use of self-reported measures of adherence among patients likely to be false-positive adherers.

  11. A FALSE POSITIVE FOR OCEAN GLINT ON EXOPLANETS: THE LATITUDE-ALBEDO EFFECT

    International Nuclear Information System (INIS)

    Cowan, Nicolas B.; Abbot, Dorian S.; Voigt, Aiko

    2012-01-01

    Identifying liquid water on the surface of planets is a high priority, as this traditionally defines habitability. One proposed signature of oceans is specular reflection ('glint'), which increases the apparent albedo of a planet at crescent phases. We post-process a global climate model of an Earth-like planet to simulate reflected light curves. Significantly, we obtain glint-like phase variations even though we do not include specular reflection in our model. This false positive is the product of two generic properties: (1) for modest obliquities, a planet's poles receive less orbit-averaged stellar flux than its equator, so the poles are more likely to be covered in highly reflective snow and ice; and (2) we show that reflected light from a modest-obliquity planet at crescent phases probes higher latitudes than at gibbous phases, therefore a planet's apparent albedo will naturally increase at crescent phase. We suggest that this 'latitude-albedo effect' will operate even for large obliquities: in that case the equator receives less orbit-averaged flux than the poles, and the equator is preferentially sampled at crescent phase. Using rotational and orbital color variations to map the surfaces of directly imaged planets and estimate their obliquity will therefore be a necessary pre-condition for properly interpreting their reflected phase variations. The latitude-albedo effect is a particularly convincing glint false positive for zero-obliquity planets, and such worlds are not amenable to latitudinal mapping. This effect severely limits the utility of specular reflection for detecting oceans on exoplanets.

  12. Breast cancer risk is increased in the years following false-positive breast cancer screening.

    Science.gov (United States)

    Goossens, Mathijs C; De Brabander, Isabel; De Greve, Jacques; Vaes, Evelien; Van Ongeval, Chantal; Van Herck, Koen; Kellen, Eliane

    2017-09-01

    A small number of studies have investigated breast cancer (BC) risk among women with a history of false-positive recall (FPR) in BC screening, but none of them has used time-to-event analysis while at the same time quantifying the effect of false-negative diagnostic assessment (FNDA). FNDA occurs when screening detects BC, but this BC is missed on diagnostic assessment (DA). As a result of FNDA, screenings that detected cancer are incorrectly classified as FPR. Our study linked data recorded in the Flemish BC screening program (women aged 50-69 years) to data from the national cancer registry. We used Cox proportional hazards models on a retrospective cohort of 298 738 women to assess the association between FPR and subsequent BC, while adjusting for potential confounders. The mean follow-up was 6.9 years. Compared with women without recall, women with a history of FPR were at an increased risk of developing BC [hazard ratio=2.10 (95% confidence interval: 1.92-2.31)]. However, 22% of BC after FPR was due to FNDA. The hazard ratio dropped to 1.69 (95% confidence interval: 1.52-1.87) when FNDA was excluded. Women with FPR have a subsequently increased BC risk compared with women without recall. The risk is higher for women who have a FPR BI-RADS 4 or 5 compared with FPR BI-RADS 3. There is room for improvement of diagnostic assessment: 41% of the excess risk is explained by FNDA after baseline screening.

  13. A Case of False-Positive Mycobacterium tuberculosis Caused by Mycobacterium celatum

    Directory of Open Access Journals (Sweden)

    Edward Gildeh

    2016-01-01

    Full Text Available Mycobacterium celatum is a nontuberculous mycobacterium shown to cause symptoms similar to pulmonary M. tuberculosis. Certain strains have been shown to cross-react with the probes used to detect M. tuberculosis, making this a diagnostic challenge. We present a 56-year-old gentleman who developed signs and symptoms of lung infection with computed tomography scan of the chest showing right lung apex cavitation. Serial sputum samples were positive for acid-fast bacilli and nucleic acid amplification testing identified M. tuberculosis ribosomal RNA, resulting in treatment initiation. Further testing with high performance liquid chromatography showed a pattern consistent with M. celatum. This case illustrates the potential for M. celatum to mimic M. tuberculosis in both its clinical history and laboratory testing due to the identical oligonucleotide sequence contained in both. An increasing number of case reports suggest that early reliable differentiation could reduce unnecessary treatment and public health intervention associated with misdiagnosed tuberculosis.

  14. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  15. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Science.gov (United States)

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  16. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. The uterine blush. A potential false-positive in Meckel's scan interpretation

    International Nuclear Information System (INIS)

    Fink-Bennett, D.

    1982-01-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations

  18. False positive localisation of C-11 methionine in a colloid nodule

    International Nuclear Information System (INIS)

    Mahajan, Sonia; Tripathi, Madhavi; Jaimini, Abhinav; Dinesh, Anant

    2011-01-01

    A 45-year-old female diagnosed with carcinoma of the left breast on histopathological examination underwent both 18 F-flourodeoxyglucose (FDG) and 11C-methionine (MET) positron emission tomography/computed tomography (PET/CT) as part of a protocol comparing the utility of these tracers for predicting a response to neoadjuvant chemotherapy in breast carcinoma. Abnormal FDG and MET accumulation was noted in the left breast primary, left axillary lymph nodes, and also in a well-defined nodule present in the left lobe of the thyroid gland. Keeping in mind the possibility of thyroid neoplasm/metastasis, the patient was referred for fine needle aspiration cytology (FNAC) from the thyroid nodule that revealed features of a simple colloid nodule. Focal thyroid lesions incidentally found on 18 F-FDG PET/CT have a high risk of thyroid malignancy. Non-specific accumulation of FDG in thyroid adenomas is also known. This case highlights a potential cause for false positive on C-11 MET PET/CT in colloid adenomas, which should be kept in mind while using this tracer for oncological indications

  19. The uterine blush. A potential false-positive in Meckel's scan interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fink-Bennett, D.

    1982-10-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.

  20. Benign oral pathology as a cause of false positive 131I uptake in thyroid carcinoma

    International Nuclear Information System (INIS)

    Mansberg, R.; Wadhwa, S.S.; Fernandes, V.B.

    1997-01-01

    Full text: We present three thyroidectomised patients with a history of thyroid carcinoma who had non-metastatic 131 I uptake due to benign oral pathology. A salivary gland study suggested impaired function but no obstruction was demonstrated on a sialogram. The symptoms resolved on antibiotic therapy and a subsequent 131 I study was normal. A subsequent thallium study demonstrated physiological tracer distribution. A 35-year-old female with papillary cell carcinoma of the thyroid demonstrated a focus of uptake on the right hemi-mandible following both a diagnostic and a therapeutic dose of 131 I. This area was tender and an OPG confirmed an area of liquefaction at this site. A 53-year-old female with medullary cell carcinoma of the thyroid demonstrated a focus of uptake in the right side of the maxilla following a diagnostic administration of 131 I. An OPG confirmed an area of liquefaction around the apex of the right upper centre. These three cases illustrate salivary gland and dental inflammation as causes of false positive 131 I uptake. It is important to differentiate non-metastatic 131 I uptake from that due to functioning metastatic thyroid carcinoma in order to avoid inappropriate treatment with large additional doses of 131 I. As in these patients, clinical assessment and the use of anatomical imaging or other isotopes such as thallium or technetium can be helpful in ruling out a mistaken diagnosis of metastasis

  1. [False positive results or what's the probability that a significant P-value indicates a true effect?

    Science.gov (United States)

    Cucherat, Michel; Laporte, Silvy

    2017-09-01

    The use of statistical test is central in the clinical trial. At the statistical level, obtaining a Pinformation about the plausibility of the existence of treatment effect. With "Pfalse positive is very high. This is the case if the power is low, if there is an inflation of the alpha risk or if the result is exploratory or chance discoveries. This possibility is important to take into consideration when interpreting the results of clinical trials in order to avoid pushing ahead significant results in appearance, but which are likely to be actually false positive results. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  2. Limited agreement of independent RNAi screens for virus-required host genes owes more to false-negative than false-positive factors.

    Directory of Open Access Journals (Sweden)

    Linhui Hao

    Full Text Available Systematic, genome-wide RNA interference (RNAi analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%. However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis.

  3. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    International Nuclear Information System (INIS)

    Zubizarreta Alberdi, Raquel; Llanes, Ana B.F.; Ortega, Raquel Almazan; Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells; Queiro Verdes, Teresa; Natal Ramos, Carmen; Sanz, Maria Ederra; Salas Trejo, Dolores

    2011-01-01

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p 14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  4. Mouse obesity network reconstruction with a variational Bayes algorithm to employ aggressive false positive control

    Directory of Open Access Journals (Sweden)

    Logsdon Benjamin A

    2012-04-01

    Full Text Available Abstract Background We propose a novel variational Bayes network reconstruction algorithm to extract the most relevant disease factors from high-throughput genomic data-sets. Our algorithm is the only scalable method for regularized network recovery that employs Bayesian model averaging and that can internally estimate an appropriate level of sparsity to ensure few false positives enter the model without the need for cross-validation or a model selection criterion. We use our algorithm to characterize the effect of genetic markers and liver gene expression traits on mouse obesity related phenotypes, including weight, cholesterol, glucose, and free fatty acid levels, in an experiment previously used for discovery and validation of network connections: an F2 intercross between the C57BL/6 J and C3H/HeJ mouse strains, where apolipoprotein E is null on the background. Results We identified eleven genes, Gch1, Zfp69, Dlgap1, Gna14, Yy1, Gabarapl1, Folr2, Fdft1, Cnr2, Slc24a3, and Ccl19, and a quantitative trait locus directly connected to weight, glucose, cholesterol, or free fatty acid levels in our network. None of these genes were identified by other network analyses of this mouse intercross data-set, but all have been previously associated with obesity or related pathologies in independent studies. In addition, through both simulations and data analysis we demonstrate that our algorithm achieves superior performance in terms of power and type I error control than other network recovery algorithms that use the lasso and have bounds on type I error control. Conclusions Our final network contains 118 previously associated and novel genes affecting weight, cholesterol, glucose, and free fatty acid levels that are excellent obesity risk candidates.

  5. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    Energy Technology Data Exchange (ETDEWEB)

    Ascunce, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Instituto de Salud Publica, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Ederra, Maria; Delfrade, Josu; Erdozain, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Baroja, Araceli [Fundacion Rioja Salud, Logrono (Spain); Zubizarreta, Raquel [Public Health and Planning Directorate, Health Office, Galician Breast Cancer Screening Programme, Galicia (Spain); Salas, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Castells, Xavier [Mar Teaching Hospital, CIBERESP, Department of Clinical Epidemiology, Barcelona (Spain)

    2012-02-15

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  6. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    International Nuclear Information System (INIS)

    Ascunce, Nieves; Ederra, Maria; Delfrade, Josu; Erdozain, Nieves; Baroja, Araceli; Zubizarreta, Raquel; Salas, Dolores; Castells, Xavier

    2012-01-01

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  7. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  8. Data from Paper “False-Positive Psychology: Undisclosed Flexibility in Data Collection and Analysis Allows Presenting Anything as Significant”

    Directory of Open Access Journals (Sweden)

    Joseph P Simmons

    2014-02-01

    Full Text Available The data includes measures collected for the two experiments reported in “False-Positive Psychology” [1] where listening to a randomly assigned song made people feel younger (Study 1 or actually be younger (Study 2. These data are useful because they illustrate inflations of false positive rates due to flexibility in data collection, analysis, and reporting of results. Data are useful for educational purposes.

  9. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  10. "Hook-like effect" causes false-negative point-of-care urine pregnancy testing in emergency patients.

    Science.gov (United States)

    Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F

    2013-01-01

    Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Minimotif Miner 3.0: database expansion and significantly improved reduction of false-positive predictions from consensus sequences.

    Science.gov (United States)

    Mi, Tian; Merlin, Jerlin Camilus; Deverasetty, Sandeep; Gryk, Michael R; Bill, Travis J; Brooks, Andrew W; Lee, Logan Y; Rathnayake, Viraj; Ross, Christian A; Sargeant, David P; Strong, Christy L; Watts, Paula; Rajasekaran, Sanguthevar; Schiller, Martin R

    2012-01-01

    Minimotif Miner (MnM available at http://minimotifminer.org or http://mnm.engr.uconn.edu) is an online database for identifying new minimotifs in protein queries. Minimotifs are short contiguous peptide sequences that have a known function in at least one protein. Here we report the third release of the MnM database which has now grown 60-fold to approximately 300,000 minimotifs. Since short minimotifs are by their nature not very complex we also summarize a new set of false-positive filters and linear regression scoring that vastly enhance minimotif prediction accuracy on a test data set. This online database can be used to predict new functions in proteins and causes of disease.

  12. The positive and negative consequences of multiple-choice testing.

    Science.gov (United States)

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  13. Interference Helps to Equalize the Read Range and Reduce False Positives of Passive RFID Tags

    DEFF Research Database (Denmark)

    Krigslund, Rasmus; Popovski, Petar; Pedersen, Gert Frølund

    2012-01-01

    In various applications of RFID systems a reader should reliably get the ID of the tags that are within a bounded proximity region, termed the interrogation zone. This gives rise to two types of errors 1) False Negative Detections (FNDs), when tags within the intended interrogation zone cannot...... interference enables design of well-defined interrogation zones for passive RFID systems....

  14. Predicting residue contacts using pragmatic correlated mutations method: reducing the false positives

    Directory of Open Access Journals (Sweden)

    Alexov Emil G

    2006-11-01

    Full Text Available Abstract Background Predicting residues' contacts using primary amino acid sequence alone is an important task that can guide 3D structure modeling and can verify the quality of the predicted 3D structures. The correlated mutations (CM method serves as the most promising approach and it has been used to predict amino acids pairs that are distant in the primary sequence but form contacts in the native 3D structure of homologous proteins. Results Here we report a new implementation of the CM method with an added set of selection rules (filters. The parameters of the algorithm were optimized against fifteen high resolution crystal structures with optimization criterion that maximized the confidentiality of the predictions. The optimization resulted in a true positive ratio (TPR of 0.08 for the CM without filters and a TPR of 0.14 for the CM with filters. The protocol was further benchmarked against 65 high resolution structures that were not included in the optimization test. The benchmarking resulted in a TPR of 0.07 for the CM without filters and to a TPR of 0.09 for the CM with filters. Conclusion Thus, the inclusion of selection rules resulted to an overall improvement of 30%. In addition, the pair-wise comparison of TPR for each protein without and with filters resulted in an average improvement of 1.7. The methodology was implemented into a web server http://www.ces.clemson.edu/compbio/recon that is freely available to the public. The purpose of this implementation is to provide the 3D structure predictors with a tool that can help with ranking alternative models by satisfying the largest number of predicted contacts, as well as it can provide a confidence score for contacts in cases where structure is known.

  15. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    Energy Technology Data Exchange (ETDEWEB)

    Zubizarreta Alberdi, Raquel [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Edificio Administrativo da Conselleria de Sanidade, Servicio de Programas Poboacionais de Cribado, Direccion Xeral de Saude Publica e Planificacion, Santiago de Compostela, Galicia (Spain); Llanes, Ana B.F.; Ortega, Raquel Almazan [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells [Department of Epidemiology and Evaluation, Institut Municipal d' Investigacio Medica-Parc de Salut Mar. CIBERESP, Barcelona (Spain); Queiro Verdes, Teresa [Galician Agency for Health Technology Assessment, Public Health and Planning Directorate, Health Office, Galicia (Spain); Natal Ramos, Carmen [Principality of Asturias Breast Cancer Screening Programme, Principality of Asturias (Spain); Sanz, Maria Ederra [Public Health Institute, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Salas Trejo, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia Breast Cancer Screening Programme, Valencia (Spain)

    2011-10-15

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p < 0.001) with greater reading volume in the previous year: OR 0.77 and OR 0.78, respectively, for a reading volume 500-1,999 mammograms and OR 0.59 and OR 0.60 for a reading volume of >14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  16. False star detection and isolation during star tracking based on improved chi-square tests.

    Science.gov (United States)

    Zhang, Hao; Niu, Yanxiong; Lu, Jiazhen; Yang, Yanqiang; Su, Guohua

    2017-08-01

    The star sensor is a precise attitude measurement device for a spacecraft. Star tracking is the main and key working mode for a star sensor. However, during star tracking, false stars become an inevitable interference for star sensor applications, which may result in declined measurement accuracy. A false star detection and isolation algorithm in star tracking based on improved chi-square tests is proposed in this paper. Two estimations are established based on a Kalman filter and a priori information, respectively. The false star detection is operated through adopting the global state chi-square test in a Kalman filter. The false star isolation is achieved using a local state chi-square test. Semi-physical experiments under different trajectories with various false stars are designed for verification. Experiment results show that various false stars can be detected and isolated from navigation stars during star tracking, and the attitude measurement accuracy is hardly influenced by false stars. The proposed algorithm is proved to have an excellent performance in terms of speed, stability, and robustness.

  17. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis

    DEFF Research Database (Denmark)

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian

    2016-01-01

    outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction...... of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each...... new trial. For each false positive, we performed TSA, using three different approaches. RESULTS: We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta...

  18. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  19. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    -ups at 2 and 12 months postscreening. At 2 months, there was a moderate multivariate effect of group on distress; and intrusive thinking and worry about breast cancer, in particular, were most frequent amongst the false positives. Intrusive thinking still prevailed at 12 months, in addition to a higher...... findings (n=1407), false-positive findings (n=492) and referents from outside the screening programme (n=1718, age 48-49 years). Distress was measured as illness worry, anxiety, depression, cancer beliefs and early detection behaviour. Measurements were one month before screening invitation with follow...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  20. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence

    Directory of Open Access Journals (Sweden)

    Phillip eGrant

    2014-09-01

    Full Text Available Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals.In this study we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy.Our results support findings that both state and trait positive schizotypy explain significant variance in seeing things that are not there and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  1. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence.

    Science.gov (United States)

    Grant, Phillip; Balser, Mona; Munk, Aisha Judith Leila; Linder, Jens; Hennig, Juergen

    2014-01-01

    Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive) schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially, the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals. In this study, we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word, or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy. Our results support findings that both state and trait positive schizotypy explain significant variance in "seeing things that are not there" and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  2. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  3. Can Implicit Associations Distinguish True and False Eyewitness Memory? Development and Preliminary Testing of the IATe.

    Science.gov (United States)

    Helm, Rebecca K; Ceci, Stephen J; Burd, Kayla A

    2016-11-01

    Eyewitness identification has been shown to be fallible and prone to false memory. In this study we develop and test a new method to probe the mechanisms involved in the formation of false memories in this area, and determine whether a particular memory is likely to be true or false. We created a seven-step procedure based on the Implicit Association Test to gauge implicit biases in eyewitness identification (the IATe). We show that identification errors may result from unconscious bias caused by implicit associations evoked by a given face. We also show that implicit associations between negative attributions such as guilt and eyewitnesses' final pick from a line-up can help to distinguish between true and false memory (especially where the witness has been subject to the suggestive nature of a prior blank line-up). Specifically, the more a witness implicitly associates an individual face with a particular crime, the more likely it is that a memory they have for that person committing the crime is false. These findings are consistent with existing findings in the memory and neuroscience literature showing that false memories can be caused by implicit associations that are outside conscious awareness. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Pathways to false-positive diagnoses using molecular genetic detection methods; Phytophthora cinnamomi a case study.

    Science.gov (United States)

    Kunadiya, Manisha; White, Diane; Dunstan, William A; Hardy, Giles E St J; Andjic, Vera; Burgess, Treena I

    2017-04-01

    Phytophthora cinnamomi is one of the world's most invasive plant pathogens affecting ornamental plants, horticultural crops and natural ecosystems. Accurate diagnosis is very important to determine the presence or absence of this pathogen in diseased and asymptomatic plants. In previous studies, P. cinnamomi species-specific primers were designed and tested using various polymerase chain reaction (PCR) techniques including conventional PCR, nested PCR and quantitative real-time PCR. In all cases, the primers were stated to be highly specific and sensitive to P. cinnamomi. However, few of these studies tested their primers against closely related Phytophthora species (Phytophthora clade 7). In this study, we tested these purported P. cinnamomi-specific primer sets against 11 other species from clade 7 and determined their specificity; of the eight tested primer sets only three were specific to P. cinnamomi. This study demonstrated the importance of testing primers against closely related species within the same clade, and not just other species within the same genus. The findings of this study are relevant to all species-specific microbial diagnosis. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. False Advertising

    OpenAIRE

    Rhodes, Andrew; Wilson, Chris M

    2016-01-01

    There is widespread evidence that some firms use false advertising to overstate the value of their products. We consider a model in which a policymaker is able to punish such false claims. We characterize an equilibrium where false advertising actively influences rational buyers, and analyze the effects of policy under different welfare objectives. We establish precise conditions where policy optimally permits a positive level of false advertising, and show how these conditions vary intuitive...

  6. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  7. Using the false memory paradigm to test two key elements of alcohol expectancy theory.

    Science.gov (United States)

    Reich, Richard R; Goldman, Mark S; Noll, Jane A

    2004-05-01

    Two key aspects of alcohol expectancy theory--(a) that memories about alcohol effects are stored as relatively cohesive templates of information and (b) that these templates are automatically activated in alcohol-related contexts--were tested using the Deese-Roediger- McDermott false memory paradigm. Alcohol expectancy adjectives were studied, and false memory for expectancy target words was tested in neutral and alcohol contexts. Results indicated that in the alcohol context heavier drinkers showed more false memory for alcohol expectancy words than they did in a neutral context. Differences were not found for lighter drinkers. These results were consistent with alcohol expectancy theory, which was then compared with various forms of association theory in explaining these results and larger issues in the addiction field. ((c) 2004 APA, all rights reserved)

  8. A False Positive I-131 Metastatic Survey Caused by Radioactive Iodine Uptake by a Benign Thymic Cyst

    Directory of Open Access Journals (Sweden)

    Avneet K. Singh

    2017-01-01

    Full Text Available Thyroid carcinoma is the most common endocrine malignancy in the United States with increasing incidence and diagnosis but stable mortality. Differentiated thyroid cancer rarely presents with distant metastases and is associated with a low risk of morbidity and mortality. Despite this, current protocols recommend remnant ablation with radioactive iodine and evaluation for local and distant metastasis in some patients with higher risk disease. There are several case reports of false positive results of metastatic surveys that are either normal physiologic variants or other pathological findings. Most false positive findings are associated with tissue that has physiologic increased uptake of I-131, such as breast tissue or lung tissue; pathological findings such as thymic cysts are also known to have increased uptake. Our case describes a rare finding of a thymic cyst found on a false positive I-131 metastatic survey. The patient was taken for surgical excision and the final pathology was a benign thymic cyst. Given that pulmonary metastases of differentiated thyroid cancer are rare, thymic cysts, though also rare, must be part of the differential diagnosis for false positive findings on an I-131 survey.

  9. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  10. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  11. Case of false positive scanning observed after radiation therapy for orbital tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, H [Gifu Prefectural Tajimi Hospital (Japan); Nakamura, K; Maeda, S; Watanabe, R; Miyajima, T

    1978-12-01

    A report was made of 56-year-old female patient of abducensparesis. In the early stage the cause remained undetermined with nothing abnormal noted in scintigraphy. Diplopia disappeared once, but right, exophalmus relapsed. In gammaencepharography, a hot spot was noted in the orbita, sinus ethmoidalis and sirus sphenoidalis. In an operation, squamous cell carcinoma was removed and radiation therapy was performed (total dose of 3520 r) and, three months later a scintigraphy disclosed a high spot of /sup 203/Hg uptake ratio in the right orbita and its lower portions. The biopsy of these portions disclosed a necrotic tissue instead of a tumor. In scintigraphy after radiation therapy against the tumor, it was reported that a positive scintigraphy was present because of the vascular trouble of said portions, although the tumor had disappeared. Attention should be given as well as an opinion of high density together with the examination by CT, especially as to enhancement.

  12. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  13. Distinguishing Binders from False Positives by Free Energy Calculations: Fragment Screening Against the Flap Site of HIV Protease

    Science.gov (United States)

    2015-01-01

    Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630

  14. A test of the submentalizing hypothesis: Apes' performance in a false belief task inanimate control

    Science.gov (United States)

    Hirata, Satoshi; Call, Josep; Tomasello, Michael

    2017-01-01

    ABSTRACT Much debate concerns whether any nonhuman animals share with humans the ability to infer others' mental states, such as desires and beliefs. In a recent eye-tracking false-belief task, we showed that great apes correctly anticipated that a human actor would search for a goal object where he had last seen it, even though the apes themselves knew that it was no longer there. In response, Heyes proposed that apes' looking behavior was guided not by social cognitive mechanisms but rather domain-general cueing effects, and suggested the use of inanimate controls to test this alternative submentalizing hypothesis. In the present study, we implemented the suggested inanimate control of our previous false-belief task. Apes attended well to key events but showed markedly fewer anticipatory looks and no significant tendency to look to the correct location. We thus found no evidence that submentalizing was responsible for apes' anticipatory looks in our false-belief task. PMID:28919941

  15. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  16. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  17. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  18. False positive results occurring in a radioimmunoassay for hepatitis A IgM antibody of the IgM class

    Energy Technology Data Exchange (ETDEWEB)

    Bucens, M R; Pietroboni, G R; Harnett, G B [Virus Lab., Combined Microbiology Service, Queen Elizabeth II Medical Centre, Perth, Western Australia

    1983-12-01

    The diagnosis of hepatitis A infection is usually based on the presence of hepatitis A specific IgM in a single serum sample. The fortuitous observation in one patient that this reactivity was apparently still present 19 mth after her original illness led to the discovery that the ABBOTT HAVAB-M kit method may produce false positive results. A series of patients who had previously had hepatitis A was retested and false positive results were found in 6% of this group. Control groups consisted of patients with other acute and chronic liver disorders and other acute viral diseases. No reactivity was detected in the control sera. Sucrose gradient fractionation revealed that the factor responsible for the false positive results was associated only with serum fractions containing IgA and IgG and that it could be removed by absorption of sera with staphylococcal protein A but not by absorption with streptococcus AR1 or by 2-mercaptoethanol treatment. It was concluded that following hepatitis A infection some patients produce a rheumatoid factor-like substance (not of IgM class) which is cleared from the serum in 2-3 yr. The presence of this factor may lead to a misdiagnosis in patients presenting with jaundice.

  19. One Hundred False-Positive Amphetamine Specimens Characterized by Liquid Chromatography Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Marin, Stephanie J; Doyle, Kelly; Chang, Annie; Concheiro-Guisan, Marta; Huestis, Marilyn A; Johnson-Davis, Kamisha L

    2016-01-01

    Some amphetamine (AMP) and ecstacy (MDMA) urine immunoassay (IA) kits are prone to false-positive results due to poor specificity of the antibody. We employed two techniques, high-resolution mass spectrometry (HRMS) and an in silico structure search, to identify compounds likely to cause false-positive results. Hundred false-positive IA specimens for AMP and/or MDMA were analyzed by an Agilent 6230 time-of-flight (TOF) mass spectrometer. Separately, SciFinder (Chemical Abstracts) was used as an in silico structure search to generate a library of compounds that are known to cross-react with AMP/MDMA IAs. Chemical formulas and exact masses of 145 structures were then compared against masses identified by TOF. Compounds known to have cross-reactivity with the IAs were identified in the structure-based search. The chemical formulas and exact masses of 145 structures (of 20 chemical formulas) were compared against masses identified by TOF. Urine analysis by HRMS correlates accurate mass with chemical formulae, but provides little information regarding compound structure. Structural data of targeted antigens can be utilized to correlate HRMS-derived chemical formulas with structural analogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Partial hydatidiform mole with false-negative urine human chorionic gonadatropin test in the emergency department.

    Science.gov (United States)

    Mundangepfupfu, Tichaendepi; Waseem, Muhammad

    2014-03-01

    Hydatidiform mole (molar pregnancy) is a benign tumor of placental trophoblastic cells, which release human chorionic gonadotropin (hCG). Several case reports have described complete hydatidiform moles with false-negative urine qualitative hCG tests. These negative pregnancy tests have been attributed to the hook effect. We report an unusual presentation of a partial mole and review an alternative explanation for the negative hCG test. As partial moles are usually not associated with a large proliferation of trophoblastic cells, levels of hCG are commonly negative and serum quantitative hCG was 1,094,950 mIU/mL. Pelvic ultrasonography showed a uterine cavity containing a soft-tissue mass with multiple cystic lesions and the hydatidiform mole was extracted with suction curettage. Tissue pathology confirmed partial hydatidiform mole. In addition to the hook effect, we present another possible explanation for the false-negative test; namely the inability of some assays to detect hCG-degradation products, which may be higher in clinical samples from patients with hydatidiform mole. This case underscores the importance of knowing the limitations of the commonly used hCG assays. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. False-negative HIV tests using oral fluid tests in children taking antiretroviral therapy from Harare, Zimbabwe.

    Science.gov (United States)

    Olaru, Ioana D; McHugh, Grace; Dakshina, Suba; Majonga, Edith; Dauya, Ethel; Bandason, Tsitsi; Kranzer, Katharina; Mujuru, Hilda; Ferrand, Rashida A

    2017-08-29

    Rapid diagnostic tests (RDT) for HIV infection have high sensitivity and specificity, but in the setting of longstanding antiretroviral therapy (ART), can give false results that can lead to misinterpretation, confusion and inadequate management. The objective of this study was to evaluate the proportion of falsely negative results of a RDT performed on oral fluid in HIV-infected children on longstanding ART. One hundred and twenty-nine children with known HIV infection and receiving ART were recruited from the HIV Clinic at the Harare Central Hospital, Zimbabwe. HIV testing was performed on oral fluid and on finger-stick blood. Children included in the study had a median age of 12 years (IQR 10-14) and 67 (51.9%) were female. Median age at HIV diagnosis was 5 years (IQR 3-6) and the median time on ART was 6.3 years (IQR 4.3-8.1). The oral fluid test was negative in 11 (8.5%) patients and indeterminate in 2 (1.6%). Finger-stick blood test was negative in 1 patient. Patients with a negative oral fluid test had a higher CD4 cell count (967 vs. 723 cells/mm 3 , p  = 0.016) and a longer time on ART (8.5 vs. 6 years, p  = 0.016). This study found that a substantial proportion of false-negative HIV test results in children on longstanding ART when using an oral fluid test. This could lead to misinterpretation of HIV test results and in the false perception of cure or delayed diagnosis.

  2. Placing symptoms in context: the role of contextual criteria in reducing false positives in Diagnostic and Statistical Manual of Mental Disorders diagnoses.

    Science.gov (United States)

    Wakefield, Jerome C; First, Michael B

    2012-02-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Multi-scale textural feature extraction and particle swarm optimization based model selection for false positive reduction in mammography.

    Science.gov (United States)

    Zyout, Imad; Czajkowska, Joanna; Grzegorzek, Marcin

    2015-12-01

    The high number of false positives and the resulting number of avoidable breast biopsies are the major problems faced by current mammography Computer Aided Detection (CAD) systems. False positive reduction is not only a requirement for mass but also for calcification CAD systems which are currently deployed for clinical use. This paper tackles two problems related to reducing the number of false positives in the detection of all lesions and masses, respectively. Firstly, textural patterns of breast tissue have been analyzed using several multi-scale textural descriptors based on wavelet and gray level co-occurrence matrix. The second problem addressed in this paper is the parameter selection and performance optimization. For this, we adopt a model selection procedure based on Particle Swarm Optimization (PSO) for selecting the most discriminative textural features and for strengthening the generalization capacity of the supervised learning stage based on a Support Vector Machine (SVM) classifier. For evaluating the proposed methods, two sets of suspicious mammogram regions have been used. The first one, obtained from Digital Database for Screening Mammography (DDSM), contains 1494 regions (1000 normal and 494 abnormal samples). The second set of suspicious regions was obtained from database of Mammographic Image Analysis Society (mini-MIAS) and contains 315 (207 normal and 108 abnormal) samples. Results from both datasets demonstrate the efficiency of using PSO based model selection for optimizing both classifier hyper-parameters and parameters, respectively. Furthermore, the obtained results indicate the promising performance of the proposed textural features and more specifically, those based on co-occurrence matrix of wavelet image representation technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  5. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  6. Small Intestinal Bacterial Overgrowth May Increase the Likelihood of Lactose and Sorbitol but not Fructose Intolerance False Positive Diagnosis.

    Science.gov (United States)

    Perets, Tsachi Tsadok; Hamouda, Dalal; Layfer, Olga; Ashorov, Olga; Boltin, Doron; Levy, Sigal; Niv, Yaron; Dickman, Ram

    2017-08-01

    Small intestinal bacterial overgrowth (SIBO) is defined as a bacterial count of more than 10 5 colony-forming units per milliliter in duodenal aspirate. It shares many symptoms with carbohydrate intolerance, which makes the clinical distinction of the disorders difficult. The aim of the study was to examine the relationship between a positive carbohydrate breath test and the presence of SIBO suggested by a positive lactulose hydrogen breath test. The electronic database of the gastroenterology laboratory of a tertiary medical center was searched for all patients clinically tested for SIBO in 2012-2013 for whom previous results for lactose, fructose, and/or sorbitol breath test were available. The correlation between positive findings for carbohydrate intolerance and for SIBO was statistically analyzed. The study group included 349 patients, 231 female and 118 male, of mean age 53±19 years. All had symptoms of abdominal bloating and gas. There was a statistically significant difference in rates of a positive breath test for lactose and sorbitol at ≤90 minutes between patients who were positive and negative for SIBO [χ 2 (1)=12.8, p <0.01 and χ 2 (1)=9.5, p <0.01 respectively]. Findings for fructose were not significant. There was no effect of age or gender. SIBO may represent an important reversible cause of carbohydrate intolerance. It may be especially prudent to exclude SIBO patients with an early peak (≤90 minutes) in H 2 excretion. © 2017 by the Association of Clinical Scientists, Inc.

  7. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University Hospital, Daegu (Korea, Republic of); Seo, Ji Hyoung [Inje University Haeundae Paik Hospital, Busan (Korea, Republic of)

    2010-12-15

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  8. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae; Seo, Ji Hyoung

    2010-01-01

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  9. False Positive Findings on I-131 WBS and SPECT/CT in Patients with History of Thyroid Cancer: Case Series

    Directory of Open Access Journals (Sweden)

    Zeina C. Hannoush

    2017-01-01

    Full Text Available Introduction. Although whole body scan (WBS with I-131 is a highly sensitive tool for detecting normal thyroid tissue and metastasis of differentiated thyroid cancer (DTC, it is not specific. Additional information, provided by single photon emission computed tomography combined with X-ray computed tomography (SPECT/CT and by the serum thyroglobulin level, is extremely useful for the interpretation of findings. Case Presentation. We report four cases of false positive WBS in patients with DTC: ovarian uptake corresponding to an endometrioma, scrotal uptake due to a spermatocele, rib-cage uptake due to an old fracture, and hepatic and renal uptake secondary to a granuloma and simple cyst, respectively. Conclusions. Trapping, organification, and storage of iodine are more prominent in thyroid tissue but not specific. Physiologic sodium-iodine symporter expression in other tissues explains some, but not all, of the WBS false positive cases. Other proposed etiologies are accumulation of radioiodine in inflamed organs, metabolism of radiodinated thyroid hormone, presence of radioiodine in body fluids, and contamination. In our cases nonthyroidal pathologies were suspected since the imaging findings were not corroborated by an elevated thyroglobulin level, which is considered a reliable tumor marker for most well-differentiated thyroid cancers. Clinicians should be aware of the potential pitfalls of WBS in DTC to avoid incorrect management.

  10. SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

    Energy Technology Data Exchange (ETDEWEB)

    Boehnke, E McKenzie; DeMarco, J; Steers, J; Fraass, B [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

  11. Recall Latencies, Confidence, and Output Positions of True and False Memories: Implications for Recall and Metamemory Theories

    Science.gov (United States)

    Jou, Jerwen

    2008-01-01

    Recall latency, recall accuracy rate, and recall confidence were examined in free recall as a function of recall output serial position using a modified Deese-Roediger-McDermott paradigm to test a strength-based theory against the dual-retrieval process theory of recall output sequence. The strength theory predicts the item output sequence to be…

  12. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    International Nuclear Information System (INIS)

    Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W.; Bryson, Stephen T.; Borucki, William J.; Knutson, Heather A.; Batalha, Natalie M.; Deming, Drake; Ford, Eric B.; Fortney, Jonathan J.; Gilliland, Ronald L.; Seager, Sara

    2015-01-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  13. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Désert, Jean-Michel; Brown, Timothy M. [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO 80309 (United States); Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bryson, Stephen T.; Borucki, William J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Batalha, Natalie M. [San Jose State University, San Jose, CA 95192 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Ford, Eric B. [University of Florida, Gainesville, FL 32611 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Gilliland, Ronald L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Seager, Sara, E-mail: desert@colorado.edu [Massachusetts Institute of Technology, Cambridge, MA 02159 (United States)

    2015-05-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  14. Trial sequential analysis reveals insufficient information size and potentially false positive results in many meta-analyses

    DEFF Research Database (Denmark)

    Brok, J.; Thorlund, K.; Gluud, C.

    2008-01-01

    in 80% (insufficient information size). TSA(15%) and TSA(LBHIS) found that 95% and 91% had absence of evidence. The remaining nonsignificant meta-analyses had evidence of lack of effect. CONCLUSION: TSA reveals insufficient information size and potentially false positive results in many meta......OBJECTIVES: To evaluate meta-analyses with trial sequential analysis (TSA). TSA adjusts for random error risk and provides the required number of participants (information size) in a meta-analysis. Meta-analyses not reaching information size are analyzed with trial sequential monitoring boundaries...... analogous to interim monitoring boundaries in a single trial. STUDY DESIGN AND SETTING: We applied TSA on meta-analyses performed in Cochrane Neonatal reviews. We calculated information sizes and monitoring boundaries with three different anticipated intervention effects of 30% relative risk reduction (TSA...

  15. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  16. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  17. Systematic hybrid LOH: a new method to reduce false positives and negatives during screening of yeast gene deletion libraries

    DEFF Research Database (Denmark)

    Alvaro, D.; Sunjevaric, I.; Reid, R. J.

    2006-01-01

    We have developed a new method, systematic hybrid loss of heterozygosity, to facilitate genomic screens utilizing the yeast gene deletion library. Screening is performed using hybrid diploid strains produced through mating the library haploids with strains from a different genetic background......, to minimize the contribution of unpredicted recessive genetic factors present in the individual library strains. We utilize a set of strains where each contains a conditional centromere construct on one of the 16 yeast chromosomes that allows the destabilization and selectable loss of that chromosome. After...... complementation of any spurious recessive mutations in the library strain, facilitating attribution of the observed phenotype to the documented gene deletion and dramatically reducing false positive results commonly obtained in library screens. The systematic hybrid LOH method can be applied to virtually any...

  18. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    Science.gov (United States)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  19. False-positive radioactive iodine uptake mimicking miliary lung metastases in a patient affected by papillary thyroid cancer and IgA deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Demidowich, Andrew Paul; Reynolds, James C. [National Institutes of Health, Bethesda (United States); Kundu, Amartya [Dept. of MedicineUniversity of Massachusetts Medical School, Worcester (United States); Celi, Francesco S. [Div. of Endocrinology and MetabolismVirginia Commonwealth UniversityRichmond (United States)

    2016-09-15

    A 42-year-old female with immunoglobulin A deficiency and recurrent sinopulmonary infections underwent thyroidectomy for papillary thyroid cancer (PTC). Follow-up {sup 123}I scintigraphy demonstrated diffuse pulmonary uptake, suggesting metastatic disease. However, subsequent pathologic, biochemical and radiographic testing proved that she was in fact disease free, and the initial {sup 123}I pulmonary uptake was identified as a false positive. Inflammatory conditions may rarely cause iodine uptake in non-thyroidal tissues due to local retention, organification, and/or immunologic utilization. To avoid exposing patients to unnecessary treatments, it is critical for clinicians to recognize that comorbid pulmonary conditions may mimic metastatic PTC on radioiodine scintigraphy.

  20. The effect of divided attention on false memory depends on how memory is tested.

    OpenAIRE

    Dewhurst, Stephen A.; Barry, Christopher; Swannell, Ellen R.; Holmes, Selina J.; Bathurst, Gemma J.

    2007-01-01

    In three experiments, we investigated the effects of divided attention on false memory, using the Deese/Roediger-McDermott (DRM) paradigm. In Experiments 1 and 2, participants studied six DRM lists with full attention and six in one of two divided-attention conditions (random number generation or digit monitoring). Both divided-attention conditions increased false recall of related words (Experiment 1) but reduced false recognition (Experiment 2). These results were confirmed in Experiment 3,...

  1. False discovery rate control incorporating phylogenetic tree increases detection power in microbiome-wide multiple testing.

    Science.gov (United States)

    Xiao, Jian; Cao, Hongyuan; Chen, Jun

    2017-09-15

    Next generation sequencing technologies have enabled the study of the human microbiome through direct sequencing of microbial DNA, resulting in an enormous amount of microbiome sequencing data. One unique characteristic of microbiome data is the phylogenetic tree that relates all the bacterial species. Closely related bacterial species have a tendency to exhibit a similar relationship with the environment or disease. Thus, incorporating the phylogenetic tree information can potentially improve the detection power for microbiome-wide association studies, where hundreds or thousands of tests are conducted simultaneously to identify bacterial species associated with a phenotype of interest. Despite much progress in multiple testing procedures such as false discovery rate (FDR) control, methods that take into account the phylogenetic tree are largely limited. We propose a new FDR control procedure that incorporates the prior structure information and apply it to microbiome data. The proposed procedure is based on a hierarchical model, where a structure-based prior distribution is designed to utilize the phylogenetic tree. By borrowing information from neighboring bacterial species, we are able to improve the statistical power of detecting associated bacterial species while controlling the FDR at desired levels. When the phylogenetic tree is mis-specified or non-informative, our procedure achieves a similar power as traditional procedures that do not take into account the tree structure. We demonstrate the performance of our method through extensive simulations and real microbiome datasets. We identified far more alcohol-drinking associated bacterial species than traditional methods. R package StructFDR is available from CRAN. chen.jun2@mayo.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  2. Sleep does not cause false memories on a story-based test of suggestibility.

    Science.gov (United States)

    van Rijn, Elaine; Carter, Neil; McMurtrie, Hazel; Willner, Paul; Blagrove, Mark T

    2017-07-01

    Sleep contributes to the consolidation of memories. This process may involve extracting the gist of learned material at the expense of details. It has thus been proposed that sleep might lead to false memory formation. Previous research examined the effect of sleep on false memory using the Deese-Roediger-McDermott (DRM) paradigm. Mixed results were found, including increases and decreases in false memory after sleep relative to wake. It has been questioned whether DRM false memories occur by the same processes as real-world false memories. Here, the effect of sleep on false memory was investigated using the Gudjonsson Suggestibility Scale. Veridical memory deteriorated after a 12-h period of wake, but not after a 12-h period including a night's sleep. No difference in false memory was found between conditions. Although the literature supports sleep-dependent memory consolidation, the results here call into question extending this to a gist-based false memory effect. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Feature-guided analysis for reduction of false positives in CAD of polyps for computed tomographic colonography

    International Nuclear Information System (INIS)

    Naeppi, Janne; Yoshida, Hiroyuki

    2003-01-01

    We evaluated the effect of our novel technique of feature-guided analysis of polyps on the reduction of false-positive (FP) findings generated by our computer-aided diagnosis (CAD) scheme for the detection of polyps from computed tomography colonographic data sets. The detection performance obtained by use of feature-guided analysis in the segmentation and feature analysis of polyp candidates was compared with that obtained by use of our previously employed fuzzy clustering technique. We also evaluated the effect of a feature called modified gradient concentration (MGC) on the detection performance. A total of 144 data sets, representing prone and supine views of 72 patients that included 14 patients with 21 colorectal polyps 5-25 mm in diameter, were used in the evaluation. At a 100% by-patient (95% by-polyp) detection sensitivity, the FP rate of our CAD scheme with feature-guided analysis based on round-robin evaluation was 1.3 (1.5) FP detections per patient. This corresponds to a 70-75 % reduction in the number of FPs obtained by use of fuzzy clustering at the same sensitivity levels. Application of the MGC feature instead of our previously used gradient concentration feature did not improve the detection result. The results indicate that feature-guided analysis is useful for achieving high sensitivity and a low FP rate in our CAD scheme

  4. Easy and Informative: Using Confidence-Weighted True-False Items for Knowledge Tests in Psychology Courses

    Science.gov (United States)

    Dutke, Stephan; Barenberg, Jonathan

    2015-01-01

    We introduce a specific type of item for knowledge tests, confidence-weighted true-false (CTF) items, and review experiences of its application in psychology courses. A CTF item is a statement about the learning content to which students respond whether the statement is true or false, and they rate their confidence level. Previous studies using…

  5. [Tropheryma whipplei and Whipple disease: false positive PCR detections of Tropheryma whipplei in diagnostic samples are rare].

    Science.gov (United States)

    Le Scanff, J; Gaultier, J B; Durand, D Vital; Durieu, I; Celard, M; Benito, Y; Vandenesch, F; Rousset, H

    2008-11-01

    PCR can be used to detect T. whipplei (Tw) in samples from variable tissue types and body fluids. We report clinical, evolutive characteristics and final diagnosis in patients with positive Tw PCR assay. Retrospective study of Tw PCR realized since 10years in a microbiology laboratory. Twenty-five Tw PCR assays were positive among 200 realized. Diagnosis was not confirmed in six cases. One patient was missing for follow up. Eighteen patients presented with Whipple's disease. Among these 18 patients, 14 had a classic Whipple's disease, three patients presented an endocarditis and one patient isolated neurological manifestations. Ten patients presented fever, seven a weight loss and 12 joint involvement. Four patients presented cutaneous manifestations, only six had gastrointestinal symptoms. Neurological involvement was reported in five cases, pulmonary symptoms in four cases, cardiac involvement in six cases and ocular signs in two cases. Anemia was reported in four patients and elevated levels of acute-phase reactants in 14 cases. Positive predictive value of Tw PCR for Whipple's disease diagnosis was 75%. Thirteen patients had a good evolution with antibiotics. Three patients presented recurrence and two cases with cardiovascular involvement died. Whipple's disease is rare but often mentioned in internist experience. The diagnosis should be every time confirmed. Tw PCR assay is an important diagnostic tool but is not sufficient to establish the diagnosis and must be interpreted with histopathology and immunohistochemical testing results.

  6. Selective activation around the left occipito-temporal sulcus for words relative to pictures: individual variability or false positives?

    Science.gov (United States)

    Wright, Nicholas D; Mechelli, Andrea; Noppeney, Uta; Veltman, Dick J; Rombouts, Serge A R B; Glensman, Janice; Haynes, John-Dylan; Price, Cathy J

    2008-08-01

    We used high-resolution fMRI to investigate claims that learning to read results in greater left occipito-temporal (OT) activation for written words relative to pictures of objects. In the first experiment, 9/16 subjects performing a one-back task showed activation in > or =1 left OT voxel for words relative to pictures (P or =1 left OT voxel for words relative to pictures. However, at this low statistical threshold false positives need to be excluded. The semantic decision paradigm was therefore repeated, within subject, in two different scanners (1.5 and 3 T). Both scanners consistently localised left OT activation for words relative to fixation and pictures relative to words, but there were no consistent effects for words relative to pictures. Finally, in a third experiment, we minimised the voxel size (1.5 x 1.5 x 1.5 mm(3)) and demonstrated a striking concordance between the voxels activated for words and pictures, irrespective of task (naming vs. one-back) or script (English vs. Hebrew). In summary, although we detected differential activation for words relative to pictures, these effects: (i) do not withstand statistical rigour; (ii) do not replicate within or between subjects; and (iii) are observed in voxels that also respond to pictures of objects. Our findings have implications for the role of left OT activation during reading. More generally, they show that studies using low statistical thresholds in single subject analyses should correct the statistical threshold for the number of comparisons made or replicate effects within subject. (c) 2007 Wiley-Liss, Inc.

  7. Cooperative testing of a positive personnel identifier

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.; Grambihler, A.J.; Graham, D.K.; Bradley, R.G.

    1980-06-01

    HEDL has a requirement to ensure the identification of remote computer terminal operators on a real-time nuclear inventory data base. The integrity of this data base depends on input from authorized individuals. Thus, a key to developing such a system is the ability to positively identify people attempting access to the system. Small scale tests of the Identimat 2000T hand geometry unit with an adjusting alogrithm have suggested a promising solution. To prove operational suitability, HEDL, in cooperation with Sandia Laboratories, has designed a large scale test of the Identimat 2000T. Data gathering on error rates, reliability, maintainability, and user acceptance will determine if the Identimat 2000T is suitable for the HEDL application. If proven acceptable, use of the Identimat 2000T can be broadened to many general applications where security information, locations and systems are required

  8. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A. P.; Stentiford, Grant D.; Flegel, Timothy W.; Sritunyalucksana, Kallaya

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers. PMID:27832178

  9. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms.

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A P; Stentiford, Grant D; Flegel, Timothy W; Sritunyalucksana, Kallaya; Itsathitphaisarn, Ornchuma

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers.

  10. False Memories Lack Perceptual Detail: Evidence from Implicit Word-Stem Completion and Perceptual Identification Tests

    Science.gov (United States)

    Hicks, J.L.; Starns, J.J.

    2005-01-01

    We used implicit measures of memory to ascertain whether false memories for critical nonpresented items in the DRM paradigm (Deese, 1959; Roediger & McDermott, 1995) contain structural and perceptual detail. In Experiment 1, we manipulated presentation modality in a visual word-stem-completion task. Critical item priming was significant and…

  11. The effects of divided attention at study and test on false recognition: a comparison of DRM and categorized lists.

    Science.gov (United States)

    Knott, Lauren M; Dewhurst, Stephen A

    2007-12-01

    Three experiments investigated the effects of divided attention at encoding and retrieval on false recognition. In Experiment 1, participants studied word lists in either full or divided attention (random number generation) conditions and then took part in a recognition test with full attention. In Experiment 2, after studying word lists with full attention, participants carried out a recognition test with either full or divided attention. Experiment 3 manipulated attention at both study and test. We also compared Deese/Roediger-McDermott (DRM) and categorized lists, due to recent claims regarding the locus of false memories produced by such lists (Smith, Gerkens, Pierce, & Choi, 2002). With both list types, false "remember" responses were reduced by divided attention at encoding and increased by divided attention at retrieval. The findings suggest that the production of false memories occurs as a result of the generation of associates at encoding and failures of source monitoring retrieval. Crucially, this is true for both DRM and categorized lists.

  12. False-negative type-specific glycoprotein G antibody responses in STI clinic patients with recurrent HSV-1 or HSV-2 DNA positive genital herpes, The Netherlands.

    Science.gov (United States)

    van Rooijen, Martijn S; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J C

    2016-06-01

    Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established by viral PCR tests) herpes simplex virus type 1 (HSV-1) or herpes simplex virus type 2 (HSV-2) genital herpes episodes. Serum samples (at minimum 3 months after t=0) were examined for the presence of gG-1-specific or gG-2-specific antibodies using the HerpeSelect 1 and 2 Immunoblot IgG, the HerpeSelect 1 and 2 enzyme linked immunoassays IgG and the LIAISON HSV-1 and HSV-2 IgG indirect chemiluminescence immunoassays. The immunoblot was HSV-1 positive in 70.6% (95% CI 44.0% to 89.7%), the LIAISON in 88.2% (95% CI 63.5% to 98.5%) and the ELISA in 82.4% (95% CI 56.6% to 96.2%) of the 17 patients with a recurrent HSV-1 episode. From 33 patients with a recurrent HSV-2 episode, the immunoblot was HSV-2 positive in 84.8% (95% CI 68.1% to 94.9%), the LIAISON in 69.7% (95% CI 51.3% to 84.4%) and the ELISA in 84.8% (95% CI 68.1% to 94.9%). Among 15/17 (88.2%; 95% CI 63.5% to 98.5%) patients with HSV-1 and 30/33 (90.1%; 95% CI 75.7% to 98.1%) patients with HSV-2, HSV-1 or HSV-2 antibodies, respectively, were detected in at least one of the three antibody tests. Commercial type-specific gG HSV-1 or HSV-2 antibody assays were false negative in 12-30% of patients with recurrent HSV-1 or HSV-2 DNA positive genital lesions. The clinical and epidemiological use of type-specific HSV serology can be hampered by false-negative results, especially if based on a single test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Armato, Samuel G. III; Li, Feng; Sone, Shusuke; Doi, Kunio

    2003-01-01

    sections), which contained 71 confirmed nodules including 66 biopsy-confirmed primary cancers, from a lung cancer screening program. The Multi-MTANN was applied to 58 true positives (nodules from 54 patients) and 1726 false positives (non-nodules) reported by our current scheme in a validation test; these were different from the training set. The results indicated that 83% (1424/1726) of non-nodules were removed with a reduction of one true positive (nodule), i.e., a classification sensitivity of 98.3% (57 of 58 nodules). By using the Multi-MTANN, the false-positive rate of our current scheme was improved from 0.98 to 0.18 false positives per section (from 27.4 to 4.8 per patient) at an overall sensitivity of 80.3% (57/71)

  14. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    Science.gov (United States)

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  15. A test of the submentalizing hypothesis: Apes' performance in a false belief task inanimate control

    OpenAIRE

    Krupenye, Christopher; Kano, Fumihiro; Hirata, Satoshi; Call, Josep; Tomasello, Michael

    2017-01-01

    Financial support came from Ministry of Education, Culture, Sports, Science and Technology (K-CONNEX to FK), Japan Society for Promotion of Science (KAKENHI 26885040, 16K21108 to FK), JSPS (KAKENHI 26245069, 24000001 to SH), and European Research Council (Synergy grant 609819 SOMICS to JC). Much debate concerns whether any nonhuman animals share with humans the ability to infer others' mental states, such as desires and beliefs. In a recent eye-tracking false-belief task, we showed that gr...

  16. Ethnic hair care products may increase false positives in hair drug testing.

    Science.gov (United States)

    Kidwell, David A; Smith, Frederick P; Shepherd, Arica R

    2015-12-01

    The question of why different races appear more susceptible to hair contamination by external drugs remains controversial. This research studied susceptibility of head hair to external cocaine and methamphetamine when hair products have been applied. Three different chemical classes of ethnic hair products were applied to Caucasian, Asian, and African hair. Some products increased the methamphetamine and cocaine concentrations in all hair types. A unique finding of this research is that certain ethnic hair products can replace moisture as a diffusion medium, thereby increasing the susceptibility to contamination over 100-fold compared to petroleum-based products. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Together I Can! Joint Attention Boosts 3- to 4-Year-Olds' Performance in a Verbal False-Belief Test.

    Science.gov (United States)

    Psouni, Elia; Falck, Andreas; Boström, Leni; Persson, Martin; Sidén, Lisa; Wallin, Maria

    2018-04-20

    Effects of joint attention were addressed on 3- to 4-year-olds' performance in a verbal false-Belief Test (FBT), featuring the experimenter as co-watcher rather than narrator. In two experiments, children (N = 183) watched a filmed-FBT jointly with a test leader, disjointed from a test leader, or alone. Children attending jointly with a test leader were more likely to pass the FBT compared with normative data and to spontaneously recall information indicating false-belief understanding, suggesting that joint attention strengthens the plausibility of the FBT and renders plot-critical information more salient. In a third experiment (N = 59), results were replicated using a typical, image-based FBT. Overall findings highlight the profound impact of experimenter as social context in verbal FBTs, and link recall of specific story features to false-belief understanding. © 2018 Society for Research in Child Development.

  18. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  19. Failure analysis on false call probe pins of microprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.

  20. Fragrance patch tests prepared in advance may give false-negative reactions.

    Science.gov (United States)

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-11-01

    Several of the ingredients in fragrance mix I (FM I) have been shown to evaporate from petrolatum preparations applied in test chambers to an extent that can be suspected to affect the patch test result. To compare the reactivity towards FM I and fragrance mix II (FM II) when they are applied in test chambers in advance and immediately prior to the patch test occasion. Seven hundred and ninety-five consecutive patients were simultaneously patch tested with duplicate samples of FM I and FM II. One sample was applied in the test chamber 6 days in advance (6D sample), and the other sample was applied immediately before the patients were patch tested (fresh sample). Twenty-two (2.8%) patients reacted exclusively to the fresh sample of FM I, 6 (0.7%) reacted exclusively to the 6D sample, and 22 (2.8%) reacted to both samples. The corresponding numbers for FM II were 9 (1.1%) for the fresh sample, 6 (0.7%) for the 6D sample and 12 (1.5%) for both samples. There was a statistically significant difference between the numbers of patients reacting to the fresh and 6D samples of FM I. No corresponding difference was observed for FM II. This can probably be explained by differences in volatilities between the ingredients of FM I and FM II. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography

  2. Measuring the Consistency in Change in Hepatitis B Knowledge among Three Different Types of Tests: True/False, Multiple Choice, and Fill in the Blanks Tests.

    Science.gov (United States)

    Sahai, Vic; Demeyere, Petra; Poirier, Sheila; Piro, Felice

    1998-01-01

    The recall of information about Hepatitis B demonstrated by 180 seventh graders was tested with three test types: (1) short-answer; (2) true/false; and (3) multiple-choice. Short answer testing was the most reliable. Suggestions are made for the use of short-answer tests in evaluating student knowledge. (SLD)

  3. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    Science.gov (United States)

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  4. Avian metapneumovirus RT-nested-PCR: a novel false positive reducing inactivated control virus with potential applications to other RNA viruses and real time methods.

    Science.gov (United States)

    Falchieri, Marco; Brown, Paul A; Catelli, Elena; Naylor, Clive J

    2012-12-01

    Using reverse genetics, an avian metapneumovirus (AMPV) was modified for use as a positive control for validating all stages of a popular established RT-nested PCR, used in the detection of the two major AMPV subtypes (A and B). Resultant amplicons were of increased size and clearly distinguishable from those arising from unmodified virus, thus allowing false positive bands, due to control virus contamination of test samples, to be identified readily. Absorption of the control virus onto filter paper and subsequent microwave irradiation removed all infectivity while its function as an efficient RT-nested-PCR template was unaffected. Identical amplicons were produced after storage for one year. The modified virus is likely to have application as an internal standard as well as in real time methods. Additions to AMPV of RNA from other RNA viruses, including hazardous examples such HIV and influenza, are likely to yield similar safe RT-PCR controls. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Is a positive intracutaneous test induced by penicillin mediated by histamine?

    DEFF Research Database (Denmark)

    Tannert, Line K; Falkencrone, Sidsel; Mortz, Charlotte G

    2017-01-01

    Background: Diagnostic workup of penicillin allergy comprises skin testing with penicillins, and patients are deemed allergic if skin test is positive. However, the literature suggests that skin test-positive patients may be challenge-negative, indicating that the skin test may be falsely positive....... Objective: To investigate real-time histamine release from a positive intracutaneous test induced by penicillin in patients with positive and negative challenges to penicillin. Methods: Skin microdialysis was performed in 21 penicillin-allergic patients with positive skin test, 13 non-allergic volunteers...... serving as negative controls, and 7 grass pollen-allergic patients serving as positive controls. Histamine was measured by microdialysis after skin test with penicillin/grass/NaCl. Penicillin challenge was subsequently performed in 12 of the patients. Results: Only 10/21 patients (47.6%) were skin test...

  6. False positive immunoglobulin m antibody to cytomegalovirus in child with infectious mononucleosis caused by epstein-barr virus infection.

    Science.gov (United States)

    Park, Jee Min; Shin, Jae Il; Lee, Jae Seung; Jang, Young Ho; Kim, Sung Hun; Lee, Kang Hyuk; Lee, Chang Hoon

    2009-10-31

    A 16-month-old boy was admitted because of cough that had lasted for 10 days. The patient showed severe hepatomegaly incidentally, and dual positivity of Immunoglobulin (Ig) M to Epstein-Barr virus (EBV) viral capsid antigen (VCA) and cytomegalovirus (CMV). On the basis of seroconversion to Epstein-Barr nuclear antigen (EBNA) Ig G positivity and reduced CMV Ig M titer with persistently negative CMV Ig G, a definite diagnosis of EBV-induced infectious mononucleosis was established 1 year 2 month later.

  7. Massive venlafaxine overdose resulted in a false positive Abbott AxSYM (R) urine immunoassay for phencyclidine

    NARCIS (Netherlands)

    Bond, GR; Steele, PE; Uges, DRA

    2003-01-01

    Case report: A 13-yr-old girl overdosed on 48 x 150 mg venlafaxine (Effexor XR(R)). She was taking venlafaxine regularly for depression. Her only other medications included topical Benzamycin and pyridoxine 50 mg daily for acne. The Abbott AxSYM(R) assay was positive only for phencyclidine, but

  8. Combination of RNA- and exome-sequencing efficiently eliminates false-positive somatic point mutations and indels – exemplified by cases of CN-AML

    DEFF Research Database (Denmark)

    Herborg, Laura Laine; Hansen, Marcus Celik; Roug, Anne Stidsholt

    Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive observat......Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive...... in the workflow, not only provides information on malignant expression profiles excluded here, but importantly help to capture the, often very few somatic mutations of myeloid leukaemia....

  9. Radiodine administration under suppression of TSH for identification of false positive receptions in patients with thyroid differentiated carcinoma (TDC): utility of the potassium perchlorate

    International Nuclear Information System (INIS)

    Santangelo, L.A.; Pitoia, F.; Sanz, C.; Niepomniszcze, H.; El Tamer, Elias

    2004-01-01

    The total body scan, after a dose of 131 I correlated with the measurement of stimulated Tg, constitute the principal pillars in follow-up of patients with TDC (thyroid differentiated carcinoma). A bibliographical search revealed more than 70 situations that can cause false total body scans positive. The examination is essential to avoid unnecessary treatment with radioiodine. The object is to evaluate the effectiveness of the radioiodine administration under hormonal therapy thyroid suppressive (THST) to eliminate the possibility of a false total body scan positive in five patients with TDC with stimulated Tg <1ng/ml

  10. Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening

    Science.gov (United States)

    Weinstein, Susan P.; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Digital breast tomosynthesis (DBT) represents a valuable addition to breast cancer screening by decreasing recall rates while increasing cancer detection rates. The increased accuracy achieved with DBT is due to the quasi–three-dimensional format of the reconstructed images and the ability to “scroll through” breast tissue in the reconstructed images, thereby reducing the effect of tissue superimposition found with conventional planar digital mammography. The margins of both benign and malignant lesions are more conspicuous at DBT, which allows improved lesion characterization, increased reader confidence, and improved screening outcomes. However, even with the improvements in accuracy achieved with DBT, there remain differences in breast cancer conspicuity by mammographic view. Early data suggest that breast cancers may be more conspicuous on craniocaudal (CC) views than on mediolateral oblique (MLO) views. While some very laterally located breast cancers may be visualized on only the MLO view, the increased conspicuity of cancers on the CC view compared with the MLO view suggests that DBT screening should be performed with two-view imaging. Even with the improved conspicuity of lesions at DBT, there may still be false-negative studies. Subtle lesions seen on only one view may be discounted, and dense and/or complex tissue patterns may make some cancers occult or extremely difficult to detect. Therefore, radiologists should be cognizant of both perceptual and cognitive errors to avoid potential pitfalls in lesion detection and characterization. ©RSNA, 2016 Online supplemental material is available for this article. PMID:27715711

  11. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  12. ABIOTIC O2 LEVELS ON PLANETS AROUND F, G, K, AND M STARS: POSSIBLE FALSE POSITIVES FOR LIFE?

    International Nuclear Information System (INIS)

    Harman, C. E.; Kasting, J. F.; Schwieterman, E. W.; Schottelkotte, J. C.

    2015-01-01

    In the search for life on Earth-like planets around other stars, the first (and likely only) information will come from the spectroscopic characterization of the planet's atmosphere. Of the countless number of chemical species terrestrial life produces, only a few have the distinct spectral features and the necessary atmospheric abundance to be detectable. The easiest of these species to observe in Earth's atmosphere is O 2 (and its photochemical byproduct, O 3 ). However, O 2 can also be produced abiotically by photolysis of CO 2 , followed by recombination of O atoms with each other. CO is produced in stoichiometric proportions. Whether O 2 and CO can accumulate to appreciable concentrations depends on the ratio of far-ultraviolet (FUV) to near-ultraviolet (NUV) radiation coming from the planet's parent star and on what happens to these gases when they dissolve in a planet's oceans. Using a one-dimensional photochemical model, we demonstrate that O 2 derived from CO 2 photolysis should not accumulate to measurable concentrations on planets around F- and G-type stars. K-star, and especially M-star planets, however, may build up O 2 because of the low NUV flux from their parent stars, in agreement with some previous studies. On such planets, a “false positive” for life is possible if recombination of dissolved CO and O 2 in the oceans is slow and if other O 2 sinks (e.g., reduced volcanic gases or dissolved ferrous iron) are small. O 3 , on the other hand, could be detectable at UV wavelengths (λ < 300 nm) for a much broader range of boundary conditions and stellar types

  13. ABIOTIC O{sub 2} LEVELS ON PLANETS AROUND F, G, K, AND M STARS: POSSIBLE FALSE POSITIVES FOR LIFE?

    Energy Technology Data Exchange (ETDEWEB)

    Harman, C. E.; Kasting, J. F. [Geosciences Department, Pennsylvania State University, University Park, PA 16802 (United States); Schwieterman, E. W. [NASA Astrobiology Institute—Virtual Planetary Laboratory (United States); Schottelkotte, J. C., E-mail: ceharmanjr@psu.edu [Astronomy Department, Pennsylvania State University, University Park, PA 16802 (United States)

    2015-10-20

    In the search for life on Earth-like planets around other stars, the first (and likely only) information will come from the spectroscopic characterization of the planet's atmosphere. Of the countless number of chemical species terrestrial life produces, only a few have the distinct spectral features and the necessary atmospheric abundance to be detectable. The easiest of these species to observe in Earth's atmosphere is O{sub 2} (and its photochemical byproduct, O{sub 3}). However, O{sub 2} can also be produced abiotically by photolysis of CO{sub 2}, followed by recombination of O atoms with each other. CO is produced in stoichiometric proportions. Whether O{sub 2} and CO can accumulate to appreciable concentrations depends on the ratio of far-ultraviolet (FUV) to near-ultraviolet (NUV) radiation coming from the planet's parent star and on what happens to these gases when they dissolve in a planet's oceans. Using a one-dimensional photochemical model, we demonstrate that O{sub 2} derived from CO{sub 2} photolysis should not accumulate to measurable concentrations on planets around F- and G-type stars. K-star, and especially M-star planets, however, may build up O{sub 2} because of the low NUV flux from their parent stars, in agreement with some previous studies. On such planets, a “false positive” for life is possible if recombination of dissolved CO and O{sub 2} in the oceans is slow and if other O{sub 2} sinks (e.g., reduced volcanic gases or dissolved ferrous iron) are small. O{sub 3}, on the other hand, could be detectable at UV wavelengths (λ < 300 nm) for a much broader range of boundary conditions and stellar types.

  14. Myositis ossificans: a false positive of malignancy in PET - CT F.D.G. and in osseous scintigraphy with HMDP 99Tc

    International Nuclear Information System (INIS)

    Hassler, S.; Bourahla, K.

    2010-01-01

    Myositis ossificans is a difficult differential diagnosis and a false positive for malignancy in both 99m Tc H.M.D.P. (hydroxy-methylene diphosphonate) scintigraphy and in exploration PET-F.D.G. This hypothesis should be mentioned in case of young patients, despite the unusual scintigraphic appearance in a benign process. (N.C.)

  15. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    Science.gov (United States)

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  16. Risk of false decision on conformity of a multicomponent material when test results of the components' content are correlated.

    Science.gov (United States)

    Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn

    2017-11-01

    The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    Science.gov (United States)

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the

  18. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  19. Letter: California's position on pregnancy testing.

    Science.gov (United States)

    Cunningham, G C

    1976-07-01

    The dangers of do-it-yourself pregnancy testing have been recognized in California resulting in the passing of legislation. Pregnancy is a c ondition which requires skill, medical assistance, and occasionally inte rvention or objective counseling. There are 4 arguments against do-it-y ourself testing: 1) it may be inaccurate or inexpertly done, 2) reagents can be hazardous to the health of users or small children, 3) it fails to save money because confirmation by health professionals is usually required, and 4) the individual may not have access to appropriate healt h care resources. California counties have been providing an increasing volume of tests that have served to encourage earlier prenatal care, earlier and safer pregnancy termination, or attendance at family planning clinics. The success of this program warrants implementation by other state governments.

  20. High prevalence of human anti-bovine IgG antibodies as the major cause of false positive reactions in two-site immunoassays based on monoclonal antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Koch, Claus; Jensen, Charlotte H

    2004-01-01

    were purified by protein G affinity chromatography from culture supernatant containing 10% (v/v) fetal calf serum (FCS). Human anti-animal IgG (bovine, mouse, horse, and swine) antibodies and human anti-bovine serum albumin antibodies were measured using an ELISA design, with direct bridging...... of the solid phase and biotinylated antigens. The false positive reactions were abolished by addition of 1% (v/v) bovine serum to the dilution buffer (DB). Human anti-bovine IgG antibodies (HABIA) were detected in 99 out of 104 sera from blood donors (50 females; 54 males). HABIA levels in male sera (n = 54......) were positively correlated to the false positive signals in the PP14 ELISA (r = 0.923; p detected in the donor sera, but levels and frequencies were lower compared to that of HABIA. Furthermore, HABIA were...

  1. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    Directory of Open Access Journals (Sweden)

    Fuminori Sakurai

    2016-01-01

    Full Text Available Circulating tumor cells (CTCs are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP–expressing conditionally replicating adenovirus (Ad (rAd-GFP was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells.

  2. Raising Awareness of False Positive Newborn Screening Results Arising from Pivalate-Containing Creams and Antibiotics in Europe When Screening for Isovaleric Acidaemia

    Directory of Open Access Journals (Sweden)

    James R. Bonham

    2018-02-01

    Full Text Available While the early and asymptomatic recognition of treatable conditions offered by newborn screening confers clear health benefits for the affected child, the clinical referral of patients with screen positive results can cause significant harm for some families. The use of pivalate-containing antibiotics and more recently the inclusion of neopentanoate as a component within moisturising creams used as nipple balms by nursing mothers can result in a significant number of false positive results when screening for isovaleric acidaemia (IVA by measuring C5 acylcarnitine. A recent survey conducted within centres from nine countries indicated that this form of contamination had been or was a significant confounding factor in the detection of IVA in seven of the nine who responded. In three of these seven the prominent cause was believed to derive from the use of moisturising creams and in another three from antibiotics containing pivalate; one country reported that the cause was mixed. As a result, four of these seven centres routinely perform second tier testing to resolve C5 isobars when an initial C5 result is elevated, and a fifth is considering making this change within their national programme. The use of creams containing neopentanoate by nursing mothers and evolving patterns in the prescription of pivalate-containing antibiotics during pregnancy require those involved in the design and operation of newborn screening programmes used to detect IVA and the doctors who receive clinical referrals from these programmes to maintain an awareness of the potential impact of this form of interference on patient results.

  3. Modified M20 Beam Position Monitor Testing

    Science.gov (United States)

    Koros, Jessica; Musson, John

    2017-09-01

    Beam position monitors (BPMs) are used to measure lateral beam position. Two pairs of modified wire BPMs are being evaluated for installation into the injector at Jefferson Lab (JLab). The BPMs were coated with a Non-Evaporable Getter (NEG) to aid in pumping at the electron gun, as an ultra-high vacuum is required to protect the gun and to avoid scattering the beam. Beam in the injector has a large diameter, allowing extraction of second moments to give information about beam profile and emittance. The purpose of this project is to determine the effects of NEG coating on the BPMs and to calculate second moments from beam models on the Goubau Line (G-Line). Using the G-Line, scans of the BPMs were taken before and after NEG coating. Each scan produced an electrical field map, which characterizes properties of the BPM, including scale factors and coupling. Second moments were calculated using superposition of previous scan data, and verification of this method was attempted using several beam models. Results show the BPMs responded well to NEG and that measurement of second moments is possible. Once the BPMs are installed, they will enhance gun vacuum and enable monitoring of shape and trajectory of the beam as it exits the electron gun to ensure quality beam for experiments. This work is made possible through support from NSF award 1659177 to Old Dominion University.

  4. Uptake of 131-I in maxillary bones mimicking salivary glands. False- positive images in patients with differentiated thyroid carcinoma (DTC )

    International Nuclear Information System (INIS)

    Degrossi, Osvaldo J.; Degrossi, E.B.; Levi de Cabrejas, Mariana

    2008-01-01

    with the intensity of the administered activity of radioiodine, the previous condition of dental integrity and in patients living in the interior of our country in zones of 'bad' water containing tracers of arsenic and fluorine. In 13 patients submitted to intense treatment of dental problems posterior WBS showed a decrease of the positive maxilla areas or they were not found. The presence of metastasis in the active maxilla area was in all cases negative. Our observations confirm that radioiodine is deposited in maxillary bone in relation of dental lesions and that this 131-I move in a very slow place. This mechanism of fixation has to be determined. We fully recommended taking into account the existence of dental illness or incomplete dental treatments when the administration of higher activities than 3.7 GBq (150 mCi). (author) [es

  5. Positive patch test reactions to oxidized limonene

    DEFF Research Database (Denmark)

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus

    2014-01-01

    to oxidized R-limonene. OBJECTIVE: To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. METHODS: Oxidized R-limonene 3.0% (containing limonene...... hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. RESULTS: Overall, exposure to products containing limonene was found...

  6. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  7. False positive of the scintigraphy with octreoscan: a diagnosis of elimination; Faux positif de la scintigraphie a l'octreoscan: un diagnostic d'elimination

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, N.; Brenot-Rossi, I.; Chuto, G.; Giovannini, M.; Delpero, J.R. [Institut Paoli-Calmettes, Marseille, (France)

    2009-05-15

    The imaging of receptors with somatostatin analogs by the pentetreotide-indium 111 (octreoscan) allows the detection of endocrine tumors essentially according to the density of S.S.T.2 receptors at the tumor level. The sensitivity of octreoscan for the detection of intestine endocrine tumors is included between 80 and 100% in the different studies. The clinical case presented here enlightens a case of false positive.We concluded to a physiological elimination of pentetreotide-indium 111 with intra pancreatic biliary stasis (perhaps a dysfunction of sphincter of ampulla of bile duct) and to the lack of tumor centre. It is here a diagnosis of elimination, supported by the different results of examination. all normal. This case of false positive induced expensive and traumatic explorations for the patient. (N.C.)

  8. False-positive positron emission tomography appearance with 18F-fluorodeoxyglucose after definitive radiotherapy for cancer of the mobile tongue.

    Science.gov (United States)

    Ariji, Y; Fuwa, N; Kodaira, T; Tachibana, H; Nakamura, T; Satoh, Y; Ariji, E

    2009-01-01

    (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is an effective tool for evaluating the results of radiotherapy. However, some false-positive appearances caused by physiological or pathological accumulation are reported. We report on three patients who showed a high accumulation of FDG in the lingual muscles but had no recurrent tumour after definitive radiotherapy for the mobile tongue. All patients had squamous cell carcinoma of the tongue and received interstitial radiotherapy with small sources. High uptake was seen in the lingual muscles without recurrence or inflammation, based on physical and MR examinations. This false-positive appearance is thought to relate to ill-balanced high activity of the lingual muscles after definitive radiotherapy.

  9. Unusual False Positive Radioiodine Uptake on 131I Whole Body Scintigraphy in Three Unrelated Organs with Different Pathologies in Patients of Differentiated Thyroid Carcinoma: A Case Series

    International Nuclear Information System (INIS)

    Ranade, Rohit; Pawar, Shwetal; Mahajan, Abhishek; Basu, Sandip

    2016-01-01

    Three cases with unusual false positive radioiodine uptake in three different organs and pathologies (infective old fibrotic lesion in the lung, simple liver cyst, and benign breast lesion) on iodine-131 ( 131 I) whole body scintigraphy. Clinicoradiological correlation was undertaken in all three cases and the pathologies were ascertained. In all the three cases, single-photon emission computerized tomography-computed tomography (SPECT-CT) and ancillary imaging modalities were employed and were helpful in arriving at the final diagnosis

  10. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  11. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension. Comparison with portographic findings of the pars umbilicus of the portal vein

    Energy Technology Data Exchange (ETDEWEB)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya [National Cancer Center, Tokyo (Japan). Hospital; Fukutake, Toshio

    1982-09-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH/sub 2/O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH/sub 2/O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered.

  12. Curved planar reformation and optimal path tracing (CROP) method for false positive reduction in computer-aided detection of pulmonary embolism in CTPA

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Guo, Yanhui; Wei, Jun; Chughtai, Aamer; Hadjiiski, Lubomir M.; Sundaram, Baskaran; Patel, Smita; Kuriakose, Jean W.; Kazerooni, Ella A.

    2013-03-01

    The curved planar reformation (CPR) method re-samples the vascular structures along the vessel centerline to generate longitudinal cross-section views. The CPR technique has been commonly used in coronary CTA workstation to facilitate radiologists' visual assessment of coronary diseases, but has not yet been used for pulmonary vessel analysis in CTPA due to the complicated tree structures and the vast network of pulmonary vasculature. In this study, a new curved planar reformation and optimal path tracing (CROP) method was developed to facilitate feature extraction and false positive (FP) reduction and improve our PE detection system. PE candidates are first identified in the segmented pulmonary vessels at prescreening. Based on Dijkstra's algorithm, the optimal path (OP) is traced from the pulmonary trunk bifurcation point to each PE candidate. The traced vessel is then straightened and a reformatted volume is generated using CPR. Eleven new features that characterize the intensity, gradient, and topology are extracted from the PE candidate in the CPR volume and combined with the previously developed 9 features to form a new feature space for FP classification. With IRB approval, CTPA of 59 PE cases were retrospectively collected from our patient files (UM set) and 69 PE cases from the PIOPED II data set with access permission. 595 and 800 PEs were manually marked by experienced radiologists as reference standard for the UM and PIOPED set, respectively. At a test sensitivity of 80%, the average FP rate was improved from 18.9 to 11.9 FPs/case with the new method for the PIOPED set when the UM set was used for training. The FP rate was improved from 22.6 to 14.2 FPs/case for the UM set when the PIOPED set was used for training. The improvement in the free response receiver operating characteristic (FROC) curves was statistically significant (p<0.05) by JAFROC analysis, indicating that the new features extracted from the CROP method are useful for FP reduction.

  13. Proportion of false-positive lesions at interim and end-of-treatment FDG-PET in lymphoma as determined by histology: Systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com; Kwee, Thomas C.

    2016-11-15

    Purpose: To systematically review and meta-analyze the proportion of false-positive lesions at interim and end-of-treatment {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in lymphoma using biopsy as reference standard. Materials and methods: Medline was searched for original studies. Methodological quality of included studies was evaluated, and results were meta-analytically summarized using random effects (in case of interstudy heterogeneity [I{sup 2} ≤ 50%]) or fixed effects (in case of no interstudy heterogeneity [I{sup 2} > 50%]). Results: Eleven studies, comprising 139 patients who underwent biopsy of an FDG-avid lesion during or after completion of antilymphoma treatment, were included. Overall methodological quality was moderate. The proportion of false-positive results among all biopsied FDG-avid lesions at PET performed during of after completion of treatment ranged between 7.7% and 90.5% (the vast majority was due to inflammatory changes), with a weighted summary proportion (random effects, I{sup 2} = 75.7%) of 55.7% (95% confidence interval [CI]: 32.6–76.6%). There were no available studies on interim FDG-PET in Hodgkin lymphoma. The pooled summary false-positive proportions were 83.0% (95% CI: 72.0%–90.2%) for interim FDG-PET in non-Hodgkin lymphoma (fixed effects, I{sup 2} = 27.7%), 23.1% (95% CI: 4.7%–64.5%) for end-of-treatment FDG-PET in Hodgkin lymphoma (random effects; I{sup 2} = 67.1%), and 31.5% (95% CI: 3.9%–83.9%) for end-of-treatment FDG-PET in non-Hodgkin lymphoma (random effects, I{sup 2} = 68.3%). Conclusion: Both interim and end-of-treatment FDG-PET scans in patients with lymphoma suffer from a very high number of false-positive FDG-avid lesions. This finding, in combination with the previously reported high number of false-negative FGD-PET scans for residual disease detection, suggests that the role of interim and end-of-treatment FDG-PET should be reconsidered.

  14. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 3. Apparent discrepancies between LLNA and GPMT sensitisation potential: False positives or differences in sensitivity?

    Science.gov (United States)

    Roberts, David W; Schultz, Terry W; Api, Anne Marie

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Next-generation sequencing indicates false-positive MRD results and better predicts prognosis after SCT in patients with childhood ALL.

    Science.gov (United States)

    Kotrova, M; van der Velden, V H J; van Dongen, J J M; Formankova, R; Sedlacek, P; Brüggemann, M; Zuna, J; Stary, J; Trka, J; Fronkova, E

    2017-07-01

    Minimal residual disease (MRD) monitoring via quantitative PCR (qPCR) detection of Ag receptor gene rearrangements has been the most sensitive method for predicting prognosis and making post-transplant treatment decisions for patients with ALL. Despite the broad clinical usefulness and standardization of this method, we and others have repeatedly reported the possibility of false-positive MRD results caused by massive B-lymphocyte regeneration after stem cell transplantation (SCT). Next-generation sequencing (NGS) enables precise and sensitive detection of multiple Ag receptor rearrangements, thus providing a more specific readout compared to qPCR. We investigated two cohorts of children with ALL who underwent SCT (30 patients and 228 samples). The first cohort consisted of 17 patients who remained in long-term CR after SCT despite having low MRD positivity (SCT monitoring using qPCR. Only one of 27 qPCR-positive samples was confirmed to be positive by NGS. Conversely, 10 of 15 samples with low qPCR-detected MRD positivity from 13 patients who subsequently relapsed were also confirmed to be positive by NGS (P=0.002). These data show that NGS has a better specificity in post-SCT ALL management and indicate that treatment interventions aimed at reverting impending relapse should not be based on qPCR only.

  16. An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening

    International Nuclear Information System (INIS)

    Nightingale, Julie M.; Borgen, Rita; Porter-Bennett, Lisa; Szczepura, Katy

    2015-01-01

    Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negative psychosocial consequences reported. Women are at increased relative risk of breast cancer therefore their attendance at subsequent screening is essential. Aims: To assess the impact of FP breast screening diagnosis and diagnostic work-up on re-attendance rates across four consecutive screening rounds at a typical breast screening centre. Method: Diagnostic interventions and screening re-attendance rates at one prior and two consecutive rounds were analysed for women receiving an FP diagnosis between 2004 and 2006. Results: 397 women (5.57%) were referred for further assessment, including 228 (57.43%) false positives. 34 eligible women failed to re-attend routine screening (+3 years), with 17 failing to re-attend subsequently (+6 years). 70.6% (24/34) of non-attenders had attended at least two screening rounds prior to FP assessment. 75% of FP women had an imaging-only assessment with 17.5% (30/171) failing to re-attend, and 25% received a biopsy, with 7% (4/57) failing to re-attend subsequently. Conclusion: This study is unique as it follows FP women through four consecutive screening rounds. FP non-attendance rates were considerably lower compared to the general screening population, with diagnostic work-up having limited influence. FP non-attendance may appear insignificant in comparison to total screened population, but these women are at greater risk of subsequent cancer so should be actively encouraged to re-engage with the screening programme

  17. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Positional stability test (roll-off resistance). 1203.15 Section 1203.15 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... over the helmet along the midsagittal plane and attaching the hook over the edge of the helmet as shown...

  18. Significance of FDG-PET in Identification of Diseases of the Appendix – Based on Experience of Two Cases Falsely Positive for FDG Accumulation

    Directory of Open Access Journals (Sweden)

    Shimpei Ogawa

    2009-04-01

    Full Text Available A discussion of the significance of F-fluorodeoxyglucose positron emission tomography (FDG-PET in the identification of diseases of the appendix is presented based on two cases falsely positive for FDG accumulation. Both cases were palpable for a tumor in the lower right abdominal region and a prominently enlarged appendix was depicted by CT. Although the patients underwent ileocecal resection based on a strong suspicion of appendiceal cancer rather than appendicitis since abnormal accumulation exhibiting maximum standard uptake values (SUVs of 7.27 and 17.11, respectively, was observed at the same site in FDG-PET examination and since there no malignant findings observed histologically, the patients were diagnosed with appendicitis. Although FDG specifically accumulates not only in malignant tumors, but also in diseases such as acute or chronic inflammation, abscesses and lymphadenitis, and identification based on SUVs has been reported to be used as a method of identification, the two cases reported here were both false-positive cases exhibiting high maximum SUVs. At the present time, although the significance of FDG-PET in the identification of diseases of the appendix is somewhat low and there are limitations on its application, various research is currently being conducted with the aim of improving diagnostic accuracy, and it is hoped that additional studies will be conducted in the future.

  19. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  20. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    Science.gov (United States)

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. False assumptions.

    Science.gov (United States)

    Swaminathan, M

    1997-01-01

    Indian women do not have to be told the benefits of breast feeding or "rescued from the clutches of wicked multinational companies" by international agencies. There is no proof that breast feeding has declined in India; in fact, a 1987 survey revealed that 98% of Indian women breast feed. Efforts to promote breast feeding among the middle classes rely on such initiatives as the "baby friendly" hospital where breast feeding is promoted immediately after birth. This ignores the 76% of Indian women who give birth at home. Blaming this unproved decline in breast feeding on multinational companies distracts attention from more far-reaching and intractable effects of social change. While the Infant Milk Substitutes Act is helpful, it also deflects attention from more pressing issues. Another false assumption is that Indian women are abandoning breast feeding to comply with the demands of employment, but research indicates that most women give up employment for breast feeding, despite the economic cost to their families. Women also seek work in the informal sector to secure the flexibility to meet their child care responsibilities. Instead of being concerned about "teaching" women what they already know about the benefits of breast feeding, efforts should be made to remove the constraints women face as a result of their multiple roles and to empower them with the support of families, governmental policies and legislation, employers, health professionals, and the media.

  2. The influence of body position on Bielschowsky's test

    Directory of Open Access Journals (Sweden)

    Carlos R. Souza-Dias

    2014-04-01

    Full Text Available Purpose: To investigate the veracity of Jampolsky's statement that Bielschowsky's head tilt test is inverted if performed with the patient in the upside-down position and to interpret its neuromuscular mechanism. Methods: We present a series of 10 patients selected from a referred sample who were diagnosed with superior oblique paresis. Hypertropia was measured in the primary position, with the head erect and tilted toward both shoulders with the patient in the erect, supine, and upside-down positions. The last position was achieved by hanging the patient upside-down. Results: As expected, our results showed the veracity of Jampolsky's statement. The forced head tilt difference was inverted or significantly decreased when the test was performed in the upside-down position. Moreover, in all patients, Bielschowsky's phenomenon was neutralized in the supine body position, in which hypertropia with the head erect tended to vanish. In 3 patients, it disappeared completely. Conclusions: This study showed that, in patients with superior oblique paresis, differences in the extent of hypertropia in Bielschowsky's test tended to vanish when the test was performed with the patient in the supine position and invert when it was performed with the patient in the upside-down position.

  3. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  4. Assessment of skin sensitization under REACH: A case report on vehicle choice in the LLNA and its crucial role preventing false positive results.

    Science.gov (United States)

    Watzek, Nico; Berger, Franz; Kolle, Susanne Noreen; Kaufmann, Tanja; Becker, Matthias; van Ravenzwaay, Bennard

    2017-04-01

    In the EU, chemicals with a production or import volume in quantities of one metric ton per year or more have to be tested for skin sensitizing properties under the REACH regulation. The murine Local Lymph Node Assay (LLNA) and its modifications are widely used to fulfil the data requirement, as it is currently considered the first-choice method for in vivo testing to cover this endpoint. This manuscript describes a case study highlighting the importance of understanding the chemistry of the test material during testing for 'skin sensitization' of MCDA (mixture of 2,4- and 2,6-diamino-methylcyclohexane) with particular focus on the vehicle used. While the BrdU-ELISA modification of the LLNA using acetone/olive oil (AOO) as vehicle revealed expectable positive results. However, the concentration control analysis unexpectedly revealed an instability of MCDA in the vehicle AOO. Further studies on the reactivity showed MCDA to rapidly react with AOO under formation of various imine structures, which might have caused the positive LLNA result. The repetition of the LLNA using propylene glycol (PG) as vehicle did not confirm the positive results of the LLNA using AOO. Finally, a classification of MCDA as skin sensitizer according to the Globally Harmonized System (GHS) was not justified. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne; Dachman, Abraham H.

    2006-01-01

    One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs may distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture

  6. Relevance of positive patch-test reactions to fragrance mix.

    Science.gov (United States)

    Devos, Steven A; Constandt, Lieve; Tupker, Ron A; Noz, Kathy C; Lucker, Georges P H; Bruynzeel, Derk P; Schuttelaar, Marie-Louise A; Kruyswijk, Mente R J; van Zuuren, Esther J; Vink, Jaqueline; Coenraads, Pieter-Jan; Kiemeney, Lambertus A L M; van der Valk, Pieter G M

    2008-01-01

    Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong reactions. To improve the appraisal of FM patch-test reactions, we studied the relevance of reactions of different strength. We also studied the predictive value of the following on the relevance of the initial FM patch-test results: patch-test results of a repeated FM test; results of patch tests with balsam of Peru, colophony, and ingredients of the mix; and (history of) atopic dermatitis. One hundred thirty-eight patients who had doubtful positive (?+) or positive (+ to +++) reactions were included in the study. We determined relevance by history taking, location and course of the dermatitis, and additional patch testing. Patients were retested with FM and with each ingredient separately. The relevance of reactions to FM increases with the strength of the reactions. Predictors of relevance are the results of retesting with FM, the results of tests with the ingredients, and a history and/or present symptoms of atopic dermatitis. Retesting with FM and its ingredients may add to the benefit of patch testing.

  7. Toward the breast screening balance sheet: cumulative risk of false positives for annual versus biennial mammograms commencing at age 40 or 50.

    Science.gov (United States)

    Winch, Caleb J; Sherman, Kerry A; Boyages, John

    2015-01-01

    This study aimed to: (1) Estimate cumulative risk of recall from breast screening where no cancer is detected (a harm) in Australia; (2) Compare women screened annually versus biennially, commencing age 40 versus 50; and (3) Compare with international findings. At the no-cost metropolitan program studied, women attended biennial screening, but were offered annual screening if regarded at elevated risk for breast cancer. The cumulative risk of at least one recall was estimated using discrete-time survival analysis. Cancer detection statistics were computed. In total, 801,636 mammograms were undertaken in 231,824 women. Over 10 years, cumulative risk of recall was 13.3 % (95 % CI 12.7-13.8) for those screened biennially, and 19.9 % (CI 16.6-23.2) for those screened annually from age 50-51. Cumulative risk of complex false positive involving a biopsy was 3.1 % (CI 2.9-3.4) and 5.0 % (CI 3.4-6.6), respectively. From age 40-41, the risk of recall was 15.1 % (CI 14.3-16.0) and 22.5 % (CI 17.9-27.1) for biennial and annual screening, respectively. Corresponding rates of complex false positive were 3.3 % (CI 2.9-3.8) and 6.3 % (CI 3.4-9.1). Over 10 mammograms, invasive cancer was detected in 3.4 % (CI 3.3-3.5) and ductal carcinoma in situ in 0.7 % (CI 0.6-0.7) of women, with a non-significant trend toward a larger proportion of Tis and T1N0 cancers in women screened annually (74.5 %) versus biennially (70.1 %), χ (2) = 2.77, p = 0.10. Cancer detection was comparable to international findings. Recall risk was equal to European estimates for women screening from 50 and lower for screening from 40. Recall risk was half of United States' rates across start age and rescreening interval categories. Future benefit/harm balance sheets may be useful for communicating these findings to women.

  8. Design, test, and calibration of an electrostatic beam position monitor

    Directory of Open Access Journals (Sweden)

    Maurice Cohen-Solal

    2010-03-01

    Full Text Available The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  9. Prevailence of Patch Test Positivity with Some Bases

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1987-01-01

    Full Text Available To evaluate the suitability of some chemicals to act as bases for antigens for patch tests, patch tests were performed with these agents in patients having contact dermatitis. Propylene glycol′used as such produced positive reactions in 25 (50% patients of which 12 were 2 + or more, polyethylene glycol 200 produced positive reactions in 9 (18% cases of which 4 cases were 2 + or more, a mixture of liquid paraffin and hard paraffin gave rise to positive reactions in 10 (10% cases 3 of these being 2 +, a mixture of liquid paraffin and bees wax was positive in 14 (14,Yo cases 3 of these being 2 +, yellow petrolatum was positive in 4 (8% cases, one of which was 2 +, white petrolatum was positive in S (6% cases all of these being + reactions only, and glycerol gave rise to a I + reaction in only one (2% caw. In tropical countries, water should be as base for as many antigens as possible for others, a control test with the b must be included.

  10. Design, test, and calibration of an electrostatic beam position monitor

    Science.gov (United States)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  11. False Positive 18F-FDG Uptake in Mediastinal Lymph Nodes Detected with Positron Emission Tomography in Breast Cancer: A Case Report

    Directory of Open Access Journals (Sweden)

    Gamze Uğurluer

    2013-01-01

    Full Text Available Breast cancer is the most frequently diagnosed cancer among females. It is accepted that lymph node involvement with metastatic tumor and the presence of distant metastasis are the most important prognostic factors. Accurate staging is important in determining prognosis and appropriate treatment. Positron emission tomography with computed tomography detects malignancies using 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG PET CT with high accuracy and they contribute to decisions regarding diagnosis, staging, recurrence, and treatment response. Here, we report a case of false positive metastatic mediastinal lymph nodes that were diagnosed by 18F-FDG PET CT in a 40-year-old breast cancer patient who had undergone preoperative evaluation. Right paratracheal, prevascular, aorticopulmonary, precarinal, subcarinal, hilar, and subhilar multiple conglomerated mediastinal lymph nodes were revealed in addition to left breast mass and axillary lymph nodes. Mediastinoscopy was performed with biopsy and pathology was reported as granulomatous lymphadenitis. In conclusion, any abnormal FDG accumulation in unusual lymph nodes must be evaluated carefully and confirmed histopathologically.

  12. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  13. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  14. Herbalife hepatotoxicity: Evaluation of cases with positive reexposure tests.

    Science.gov (United States)

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Schwarzenboeck, Alexander; Eickhoff, Axel

    2013-07-27

    To analyze the validity of applied test criteria and causality assessment methods in assumed Herbalife hepatotoxicity with positive reexposure tests. We searched the Medline database for suspected cases of Herbalife hepatotoxicity and retrieved 53 cases including eight cases with a positive unintentional reexposure and a high causality level for Herbalife. First, analysis of these eight cases focused on the data quality of the positive reexposure cases, requiring a baseline value of alanine aminotransferase (ALT) Herbalife in these eight cases were probable (n = 1), unlikely (n = 4), and excluded (n = 3). Confounding variables included low data quality, alternative diagnoses, poor exclusion of important other causes, and comedication by drugs and herbs in 6/8 cases. More specifically, problems were evident in some cases regarding temporal association, daily doses, exact start and end dates of product use, actual data of laboratory parameters such as ALT, and exact dechallenge characteristics. Shortcomings included scattered exclusion of hepatitis A-C, cytomegalovirus and Epstein Barr virus infection with only globally presented or lacking parameters. Hepatitis E virus infection was considered in one single patient and found positive, infections by herpes simplex virus and varicella zoster virus were excluded in none. Only one case fulfilled positive reexposure test criteria in initially assumed Herbalife hepatotoxicity, with lower CIOMS based causality gradings for the other cases than hitherto proposed.

  15. Prevalence of Mantoux test positivity among apparently healthy ...

    African Journals Online (AJOL)

    Prevalence of Mantoux test positivity among apparently healthy children in Maiduguri, Nigeria. MG Mustapha, AM Garba, AI Rabasa, MS Gimba. Abstract. Background. The impact of tuberculosis (TB) is highest in the developing countries of Asia and Africa, especially among children, in whom the diagnosis is challenging.

  16. [Characteristics of allergic conjunctivitis with positive skin prick test].

    Science.gov (United States)

    Yang, S; Jiang, Y; Jin, Y M; Zhang, J Y; Li, Y

    2017-09-11

    Objective: To observe the clinical characteristics of allergic conjunctivitis, and the correlations with skin prick test results. Methods: A retrospective study. Forty patients with positive skin prick test result were included. Patients underwent an ophthalmologic examination to identify their primary presenting signs and symptoms. The allergy types were divided into 5 groups. All dates were analyzed for the dependence, normality and homogeneity of variance. Chi-square test, Mann-Whitney U test, Kruskal-Wallis H test and Spearman correlation analysis were performed accordingly. Results: Among 40 patients, 18(45.0%) had a clinical diagnosis of seasonal allergic conjunctivitis, 14(35.0%) had perennial allergic conjunctivitis, 5(12.5%) had vernal keratoconjunctivitis, and 2(5.0%) had atopic keratoconjunctivits, and 1(2.5%) had giant papillary conjunctivitis. There was no significant difference in the number of symptoms and signs score among different types of allergic conjunctivitis, the score of itching and hyperemia had a positive relationship with the number of positive allergens ( r =0.74, Ptest of the allergen, the more symptoms and signs encountered in terms of severity. Conclusion: Seasonal allergic conjunctivitis was the most prevalent disorder, the most important clinical characteristics of allergic conjunctivitis are itching and conjunctival congestion, the main allergens are dust and pollens, patients may be sensitive to multiple allergens. (Chin J Ophthalmol, 2017, 53: 689-693) .

  17. Contamination in the Kepler field. Identification of 685 KOIs as false positives via ephemeris matching based ON Q1-Q12 data

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, Jeffrey L.; Thompson, Susan E.; Burke, Christopher J.; Caldwell, Douglas A.; Jenkins, Jon M.; Mullally, Fergal R.; Rowe, Jason F. [SETI Institute, 189 Bernardo Avenue, Mountain View, CA 94043 (United States); Bryson, Stephen T.; Haas, Michael R.; Howell, Steve B. [NASA Ames Research Center, M/S 244-30, Moffett Field, CA 94035 (United States); Christiansen, Jessie L. [NASA Exoplanet Science Institute, California Institute of Technology, Pasadena CA 91125 (United States); Kolodziejczak, Jeffery J., E-mail: jeffrey.l.coughlin@nasa.gov [NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States)

    2014-05-01

    The Kepler mission has to date found almost 6000 planetary transit-like signals, utilizing three years of data for over 170,000 stars at extremely high photometric precision. Due to its design, contamination from eclipsing binaries, variable stars, and other transiting planets results in a significant number of these signals being false positives (FPs). This directly affects the determination of the occurrence rate of Earth-like planets in our Galaxy, as well as other planet population statistics. In order to detect as many of these FPs as possible, we perform ephemeris matching among all transiting planet, eclipsing binary, and variable star sources. We find that 685 Kepler Objects of Interest (KOIs)—12% of all those analyzed—are FPs as a result of contamination, due to 409 unique parent sources. Of these, 118 have not previously been identified by other methods. We estimate that ∼35% of KOIs are FPs due to contamination, when performing a first-order correction for observational bias. Comparing single-planet candidate KOIs to multi-planet candidate KOIs, we find an observed FP fraction due to contamination of 16% and 2.4% respectively, bolstering the existing evidence that multi-planet KOIs are significantly less likely to be FPs. We also analyze the parameter distributions of the ephemeris matches and derive a simple model for the most common type of contamination in the Kepler field. We find that the ephemeris matching technique is able to identify low signal-to-noise FPs that are difficult to identify with other vetting techniques. We expect FP KOIs to become more frequent when analyzing more quarters of Kepler data, and note that many of them will not be able to be identified based on Kepler data alone.

  18. Caprine and ovine Greek dairy products: The official German method generates false-positive results due to κ-casein gene polymorphism.

    Science.gov (United States)

    Tsartsianidou, V; Triantafillidou, D; Karaiskou, N; Tarantili, P; Triantafillidis, G; Georgakis, E; Triantafyllidis, A

    2017-05-01

    Caseins are widely used for species identification of dairy products. Isoelectric focusing (IEF) of para-κ-casein peptide is used as the official German method for the differentiation between caprine (isoform A) and ovine (isoform B) dairy products, based on their different isoelectric points. The discrimination between Greek goat and ewe dairy products using IEF has, however, been shown to be problematic because of the existence of the ewe isoform in milk from Greek indigenous dairy goats. This could be due to nucleotide polymorphisms within the goat κ-casein gene of Greek indigenous breeds, which alter the isoelectric point of the para-κ-casein peptide and lead to false positive results. Previous DNA analysis of the goat κ-casein gene has shown high levels of polymorphism; however, no such information is available for Greek indigenous dairy goats. Therefore, 87 indigenous dairy goats were sequenced at exon IV of κ-casein gene. In total, 9 polymorphic sites were detected. Three nonsynonymous point mutations were identified, which change the isoelectric point of the goat para-κ-casein peptide so that it appears identical to that of the ewe peptide. Ten composite genotypes were reconstructed and 6 of them included the problematic point mutations. For the verification of genetic results, IEF was carried out. Both goat and ewe patterns appeared in the problematic genotypes. The frequency of these genotypes could be characterized as moderate (0.23) to high (0.60) within Greek indigenous breeds. However, this is not an issue restricted to Greece, as such genotypes have been detected in various non-Greek goat breeds. In conclusion, IEF based on the official German method is certainly inappropriate for ovine and caprine discrimination concerning Greek dairy goat products, and consequently a new method should be established. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Using Reduced Inoculum Densities of Mycobacterium tuberculosis in MGIT Pyrazinamide Susceptibility Testing to Prevent False-Resistant Results and Improve Accuracy: A Multicenter Evaluation

    Directory of Open Access Journals (Sweden)

    Glenn P. Morlock

    2017-01-01

    Full Text Available The primary platform used for pyrazinamide (PZA susceptibility testing of Mycobacterium tuberculosis is the MGIT culture system (Becton Dickinson. Since false-resistant results have been associated with the use of this system, we conducted a multicenter evaluation to determine the effect of using a reduced cell density inoculum on the rate of false resistance. Two reduced inoculum densities were compared with that prescribed by the manufacturer (designated as “BD” method. The reduced inoculum methods (designated as “A” and “C” were identical to the manufacturer’s protocol in all aspects with the exception of the cell density of the inoculum. Twenty genetically and phenotypically characterized M. tuberculosis isolates were tested in duplicate by ten independent laboratories using the three inoculum methods. False-resistant results declined from 21.1% using the standard “BD” method to 5.7% using the intermediate (“A” inoculum and further declined to 2.8% using the most dilute (“C” inoculum method. The percentages of the resistant results that were false-resistant declined from 55.2% for the “BD” test to 28.8% and 16.0% for the “A” and “C” tests, respectively. These results represent compelling evidence that the occurrence of false-resistant MGIT PZA susceptibility test results can be mitigated through the use of reduced inoculum densities.

  20. Improvement of human cell line activation test (h-CLAT) using short-time exposure methods for prevention of false-negative results.

    Science.gov (United States)

    Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi

    2018-01-01

    Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogK ow ) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogK ow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogK ow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.

  1. MARVELS-1: A FACE-ON DOUBLE-LINED BINARY STAR MASQUERADING AS A RESONANT PLANETARY SYSTEM AND CONSIDERATION OF RARE FALSE POSITIVES IN RADIAL VELOCITY PLANET SEARCHES

    International Nuclear Information System (INIS)

    Wright, Jason T.; Roy, Arpita; Mahadevan, Suvrath; Wang, Sharon X.; Fleming, Scott W.; Ford, Eric B.; Payne, Matt; Lee, Brian L.; Ge, Jian; Wang, Ji; Crepp, Justin R.; Gaudi, B. Scott; Eastman, Jason; Pepper, Joshua; Cargile, Phillip; Stassun, Keivan G.; Ghezzi, Luan; González-Hernández, Jonay I.; Wisniewski, John; Dutra-Ferreira, Leticia

    2013-01-01

    We have analyzed new and previously published radial velocity (RV) observations of MARVELS-1, known to have an ostensibly substellar companion in a ∼6 day orbit. We find significant (∼100 m s –1 ) residuals to the best-fit model for the companion, and these residuals are naïvely consistent with an interior giant planet with a P = 1.965 days in a nearly perfect 3:1 period commensurability (|P b /P c – 3| –4 ). We have performed several tests for the reality of such a companion, including a dynamical analysis, a search for photometric variability, and a hunt for contaminating stellar spectra. We find many reasons to be critical of a planetary interpretation, including the fact that most of the three-body dynamical solutions are unstable. We find no evidence for transits, and no evidence of stellar photometric variability. We have discovered two apparent companions to MARVELS-1 with adaptive optics imaging at Keck; both are M dwarfs, one is likely bound, and the other is likely a foreground object. We explore false-alarm scenarios inspired by various curiosities in the data. Ultimately, a line profile and bisector analysis lead us to conclude that the ∼100 m s –1 residuals are an artifact of spectral contamination from a stellar companion contributing ∼15%-30% of the optical light in the system. We conclude that origin of this contamination is the previously detected RV companion to MARVELS-1, which is not, as previously reported, a brown dwarf, but in fact a G dwarf in a face-on orbit.

  2. Characteristics of children with positive tuberculin skin test.

    Science.gov (United States)

    Hocaoğlu, Arzu Babayiğit; Erge, Duygu Olmez; Anal, Ozden; Makay, Balahan; Uzuner, Nevin; Karaman, Ozkan

    2011-01-01

    The aim of the study was to define the characteristics of children with latent tuberculosis diagnosed with positive tuberculin skin test (TST) and evaluate potential risk factors in children with positive TST. Children followed with the diagnosis of latent tuberculosis infection were included in the study retrospectively. Demographic characteristics of patients including history of atopy, respiratory infections, family history of tuberculosis and atopy, number of BCG vaccinations, findings of physical examination and laboratory data were extracted from patient's file. Eighty-one children (51 male, 30 female) who had positive TST were retrospectively evaluated in the study. Mean age of the patients was 8.00 ± 4.00 years. Only 13 (16%) of the children had contact with a case who had active tuberculosis. It was shown that the age of the patients, number of BCG scars and BCG vaccination significantly affected TST reaction size. TST size was not affected with time passed after last dose of BCG vaccination, family history of tuberculosis, presence of TST positive case in the family, exposure to cigarette smoke, number of household family members and presence of respiratory allergic disease. The patient's age, numbers of BCG vaccination and BCG scars significantly affect TST results in childhood. This may cause difficulty in diagnosing latent tuberculosis infection and in decision of initiating prophylactic treatment. The results of this study may show that recently developed, more accurate and convenient in vitro tests that they have higher costs and require sophisticated laboratory, can be used to diagnose latent tuberculosis.

  3. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    Energy Technology Data Exchange (ETDEWEB)

    Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp [Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi 470-1192 (Japan); Fujita, Hiroshi [Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University, 1-1 Yanagido, Gifu 501-1194 (Japan); Yamamuro, Osamu; Tamaki, Tsuneo [East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi 464-0044 (Japan)

    2016-06-15

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  4. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    International Nuclear Information System (INIS)

    Teramoto, Atsushi; Fujita, Hiroshi; Yamamuro, Osamu; Tamaki, Tsuneo

    2016-01-01

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  5. Emotions and false memories: valence or arousal?

    Science.gov (United States)

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  6. Beam test of the 2D position sensitive neutron detector

    International Nuclear Information System (INIS)

    Tian Lichao; Chen Yuanbo; Sun Zhijia; Tang Bin; Zhou Jianrong; Qi Huirong; Liu Rongguang; Zhang Jian; Yang Guian; Xu Hong

    2014-01-01

    China Spallation Neutron Source (CSNS), one of the Major scientific apparatuses of the national Eleventh Five-Year Plane, is under construction and three spectrumeters will be constructed in the first phase of the project. A 2D position sensitive neutron detector has been constructed for the Multifunctional Reflect spectrumeter (MR) in Institute of High Energy Physics (IHEP). The basic operation principle of the detector and the test on the residual stress diffractometer of Chinese Advanced Research Reactor (CARR) in China Institute of Atomic Energy (CIAE) is introduced in this paper. The results show that it has a good position resolution of l.18 mm (FWHM) for the neutrons of l.37 A and 2D imaging ability, which is consistent with the theory. It can satisfy the requirements of MR and lays the foundation for the construction of larger neutron detectors. (authors)

  7. Yersinia enterocolitica: an unlikely cause of positive brucellosis tests in greater yellowstone ecosystem bison (Bison bison).

    Science.gov (United States)

    See, Wade; Edwards, William H; Dauwalter, Stacey; Almendra, Claudia; Kardos, Martin D; Lowell, Jennifer L; Wallen, Rick; Cain, Steven L; Holben, William E; Luikart, Gordon

    2012-07-01

    Yersinia enterocolitica serotype O:9 has identical O-antigens to those of Brucella abortus and has apparently caused false-positive reactions in numerous brucellosis serologic tests in elk (Cervus canadensis) from southwest Montana. We investigated whether a similar phenomenon was occurring in brucellosis antibody-positive bison (Bison bison) using Y. enterocolitica culturing techniques and multiplex PCR of four diagnostic loci. Feces from 53 Yellowstone bison culled from the population and 113 free-roaming bison from throughout the Greater Yellowstone Ecosystem (GYE) were tested. Yersinia enterocolitica O:9 was not detected in any of 53 the bison samples collected at slaughter facilities or in any of the 113 fecal samples from free-ranging bison. One other Y. enterocolitica serotype was isolated; however, it is not known to cause cross-reaction on B. abortus serologic assays because it lacks the perosamine synthetase gene and thus the O-antigens. These findings suggest that Y. enterocolitica O:9 cross-reactivity with B. abortus antigens is unlikely to have been a cause of false-positive serology tests in GYE bison and that Y. enterocolitica prevalence was low in bison in the GYE during this study.

  8. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  9. Output Position and Word Relatedness Effects in a DRM Paradigm: Support for a Dual-Retrieval Process Theory of Free Recall and False Memories

    Science.gov (United States)

    Barnhardt, T. M.; Choi, H.; Gerkens, D. R.; Smith, S. M.

    2006-01-01

    Five experiments investigated predictions--derived from a dual-retrieval process approach to free recall (Brainerd, C. J., Wright, R., Reyna, V. F., & Payne, D. G. (2002). Dual-retrieval processes in free and associative recall. Journal of Memory and Language, 46, 120-152.)--about false memories in a DRM-like paradigm. In all the experiments, the…

  10. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    Science.gov (United States)

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Microbiological evaluation of milk samples positive to California Mastitis Test in dairy buffalo cows (Buballus bubalis

    Directory of Open Access Journals (Sweden)

    D.J. Sturion

    2010-02-01

    Full Text Available In order to observe the microbiological status of CMT positive samples, 734 apparently health mammary quarters from buffalo cows were submitted to physical evaluation, strip cup test and CMT. After milk samples inoculation in 10% ovine blood agar base media and in MacConkey agar and incubation under aerobic condition for 72 hours at 37oC, identification was proceeded. According to CMT, 227 quarters (30,93% were positive, among them 73 (32,16% presented 1+ reaction, 53 (23,35% were 2+ and 101 (44,49% were 3+. Microbiological exams of such samples were positive in 147 (64,76% out of 227 CMT positive samples and among the remaining 72 (31,72% were negative and 8 (3,52 were contaminated. In the 147 microbiological positive samples 204 bacteria were found in pure or associated growth and the most frequent agents were: Corynebacterium sp (59,25%; Staphylococcus sp (17,65% among which 86,11% were coagulase negative and 13,89% were coagulase positive; and Micrococcus sp (6,37%. The results revealed that, excluding the eight contaminated samples, 147 (67,12% quarters out of 219 CMT positive could be considered as bacteria-carrier and that even in a smaller percentage false-positive results can cause problems in a sanitary program for mastitis control in dairy buffalo cows.

  12. Inflammatory myofibroblastic tumor of the mesentery associated with high fever and positive Widal test

    International Nuclear Information System (INIS)

    Chouairy, Camil J.; Bechara, Elie A.; Ghabril, Ramy H.; Gebran, Sleiman J.

    2008-01-01

    Inflammatory myofibroblastic tumor (IMT) is associated in 15-30% of cases with systemic symptomatology , such as prolonged fever, weight loss, elevated erythrocyte sedimentation rate (ESR) , anemia, thrombocytosis and leukocytosis. We report the case of a 4-year-old Lebanese boy who presented with high-grade fever of long duration and a single (unpaired) positive Widal agglutination test. Blood culture was negative. A diagnosis of typhoid fever was made. An abdominal (mesenteric) IMT was incidentally discovered, 30 days after the fever had appeared. After surgery, the fever disappeared immediately, and the ESR returned. We strongly favor the possibility of a false positive Widal test, due to polyclonal increase in serum immunoglobulins, which often occurs in IMT. We also think that IMT might be a mimicker of typhoid fever, both clinically and serologically. Physicians, especially pediatricians practicing in endemic areas, should probably be aware of this mimicry. (author)

  13. Inflammatory myofibroblastic tumor of the mesentery associated with high fever and positive Widal test

    Energy Technology Data Exchange (ETDEWEB)

    Chouairy, Camil J [Dept. of Pathology, Saint George Hospital, Beirut (Lebanon); Bechara, Elie A; Ghabril, Ramy H [Dept. of Pediatrics, Saint George Hospital, Beirut (Lebanon); Gebran, Sleiman J [Dept. of Pediatric Surgery, AlHada Armed Forces Hospital, Taif (Saudi Arabia)

    2008-07-01

    Inflammatory myofibroblastic tumor (IMT) is associated in 15-30% of cases with systemic symptomatology , such as prolonged fever, weight loss, elevated erythrocyte sedimentation rate (ESR) , anemia, thrombocytosis and leukocytosis. We report the case of a 4-year-old Lebanese boy who presented with high-grade fever of long duration and a single (unpaired) positive Widal agglutination test. Blood culture was negative. A diagnosis of typhoid fever was made. An abdominal (mesenteric) IMT was incidentally discovered, 30 days after the fever had appeared. After surgery, the fever disappeared immediately, and the ESR returned. We strongly favor the possibility of a false positive Widal test, due to polyclonal increase in serum immunoglobulins, which often occurs in IMT. We also think that IMT might be a mimicker of typhoid fever, both clinically and serologically. Physicians, especially pediatricians practicing in endemic areas, should probably be aware of this mimicry. (author)

  14. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Science.gov (United States)

    2010-01-01

    ... contractor, to have the potential to significantly affect the environment, public health and safety, or... evidence of the use of illegal drugs of employees in testing designated positions identified in this... section shall provide for random tests at a rate equal to 30 percent of the total number of employees in...

  15. The diagnosis of nonclassic congenital adrenal hyperplasia due to 21-hydroxylase deficiency, based on serum basal or post-ACTH stimulation 17-hydroxyprogesterone, can lead to false-positive diagnosis.

    Science.gov (United States)

    Ambroziak, Urszula; Kępczyńska-Nyk, Anna; Kuryłowicz, Alina; Małunowicz, Ewa Maria; Wójcicka, Anna; Miśkiewicz, Piotr; Macech, Magdalena

    2016-01-01

    As nonclassic congenital adrenal hyperplasia (NCCAH) needs to be taken into account in women with hyperandrogenism, we aimed to assess whether the recommended level of poststimulated 17OHP ≥30 nmol/l confirms NCCAH. Forty, consecutive women with biochemical and/or clinical hyperandrogenism (aged 25·4, 18-38) suspected of having NCCAH were recruited to the study. In patients with 17OHP level between 5·1 and 29·9 nmol/l an ACTH stimulation test was performed. In patients with basal or poststimulated 17OHP ≥30 nmol/l, twenty-four-hour urinary steroid profile (USP) analysis was performed and CYP21A2 mutation was assessed. In selected patients with poststimulated 17OHP basal or poststimulated 17OHP ≥30 nmol/l (group A) and with poststimulated 17OHP basal or poststimulated 17OHP ≥30 nmol/l was found in 21, but NCCAH was confirmed by USP followed by genetic testing only in 5 (24%). Four patients were diagnosed as heterozygotes, and in twelve, no CYP21A2 mutation was detected. The diagnosis of NCCAH based only on serum 17OHP measurements (basal or poststimulated) may lead to false-positive diagnosis when performed by immunoassay with a cut-off value of ≥30 nmol/l. The definitive diagnosis can be established based on USP and/or genetic testing. © 2015 John Wiley & Sons Ltd.

  16. Integrated built-in-test false and missed alarms reduction based on forward infinite impulse response & recurrent finite impulse response dynamic neural networks

    Science.gov (United States)

    Cui, Yiqian; Shi, Junyou; Wang, Zili

    2017-11-01

    Built-in tests (BITs) are widely used in mechanical systems to perform state identification, whereas the BIT false and missed alarms cause trouble to the operators or beneficiaries to make correct judgments. Artificial neural networks (ANN) are previously used for false and missed alarms identification, which has the features such as self-organizing and self-study. However, these ANN models generally do not incorporate the temporal effect of the bottom-level threshold comparison outputs and the historical temporal features are not fully considered. To improve the situation, this paper proposes a new integrated BIT design methodology by incorporating a novel type of dynamic neural networks (DNN) model. The new DNN model is termed as Forward IIR & Recurrent FIR DNN (FIRF-DNN), where its component neurons, network structures, and input/output relationships are discussed. The condition monitoring false and missed alarms reduction implementation scheme based on FIRF-DNN model is also illustrated, which is composed of three stages including model training, false and missed alarms detection, and false and missed alarms suppression. Finally, the proposed methodology is demonstrated in the application study and the experimental results are analyzed.

  17. False-negative type-specific glycoprotein G antibody responses in STI clinic patients with recurrent HSV-1 or HSV-2 DNA positive genital herpes, The Netherlands

    NARCIS (Netherlands)

    van Rooijen, Martijn S.; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J. C.

    2016-01-01

    Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established

  18. Feedback enhances the positive effects and reduces the negative effects of multiple-choice testing.

    Science.gov (United States)

    Butler, Andrew C; Roediger, Henry L

    2008-04-01

    Multiple-choice tests are used frequently in higher education without much consideration of the impact this form of assessment has on learning. Multiple-choice testing enhances retention of the material tested (the testing effect); however, unlike other tests, multiple-choice can also be detrimental because it exposes students to misinformation in the form of lures. The selection of lures can lead students to acquire false knowledge (Roediger & Marsh, 2005). The present research investigated whether feedback could be used to boost the positive effects and reduce the negative effects of multiple-choice testing. Subjects studied passages and then received a multiple-choice test with immediate feedback, delayed feedback, or no feedback. In comparison with the no-feedback condition, both immediate and delayed feedback increased the proportion of correct responses and reduced the proportion of intrusions (i.e., lure responses from the initial multiple-choice test) on a delayed cued recall test. Educators should provide feedback when using multiple-choice tests.

  19. Abiotic production of nitrous oxide by lightning. Implications for a false positive identification of life on Earth-Like Planets around quiescent M Dwarfs

    Science.gov (United States)

    Navarro, Karina F.; Navarro-Gonzalez, Rafael; McKay, Christopher P.

    _{2} dominated primitive Earth-like atmospheres. However, during the rise in atmospheric O _{2} at the start of the Proterozoic, the ocean became stratified (anoxic at the bottom and oxygenic at the surface). During this period, the emissions of N _{2}O were probably higher than today associated with a stronger microbial activity in the early anoxic ocean layer (Grenfell et al., 2011). Under this scenario, the predicted N _{2}O concentration would be about 3920 ppb, considering 10% the current atmospheric O _{2} concentrations, 100 times higher the current microbial N _{2}O flux, and a fainter Sun (94.3%) (Grenfell et al., 2011). This concentration would be still undetectable (Grenfell et al., 2011). A completely different scenario could be expected in Earth-like planets orbiting M dwarfs, which are the most abundant stars in the galaxy, representing about 75% of the total stellar population. M stars exhibit a large range in activity levels from very low levels of chromospheric and coronal activity, the so-called “quiescent” to high levels, the so-called “active" states. Photochemical models predict that the N _{2}O concentration would only increase to about 1,000 ppb for the current Earth orbiting an active M star, but surprisingly up to about 1,000 ppm for the current Earth orbiting a quiescent M star (Segura et al., 2005). Therefore, N _{2}O becomes a promising biomarker. Under this scenario it is important to constrain the abiotic sources of N _{2}O under different atmospheric conditions to avoid a false positive identification of life. Here we report an experimental study of the effects of lightning discharges on the nitrogen fixation rate during the evolution of the Earth’s early atmosphere from 10 to 1 percent of carbon dioxide in molecular nitrogen. We extended our study from no methane up to 1,000 ppm CH _{4}, which would be applicable to the postbiotic Earth (Tian et al., 2011). Lightning was simulated in the laboratory by a plasma generated with a

  20. Predictors for benign paroxysmal positional vertigo with positive Dix–Hallpike test

    Directory of Open Access Journals (Sweden)

    Noda K

    2011-12-01

    Full Text Available Kazutaka Noda, Masatomi Ikusaka, Yoshiyuki Ohira, Toshihiko Takada, Tomoko TsukamotoDepartment of General Medicine, Chiba University Hospital, Chiba, JapanObjective: Patient medical history is important for making a diagnosis of causes of dizziness, but there have been no studies on the diagnostic value of individual items in the history. This study was performed to identify and validate useful questions for suspecting a diagnosis of benign paroxysmal positional vertigo (BPPV.Methods: Construction and validation of a disease prediction model was performed at the outpatient clinic in the Department of General Medicine of Chiba University Hospital. Patients with dizziness were enrolled (145 patients for construction of the disease prediction model and 61 patients for its validation. This study targeted BPPV of the posterior semicircular canals only with a positive Dix–Hallpike test (DHT + BPPV to avoid diagnostic ambiguity. Binomial logistic regression analysis was performed to identify the items that were useful for diagnosis or exclusion of DHT + BPPV.Results: Twelve patients from the derivation set and six patients from the validation set had DHT + BPPV. Binomial logistic regression analysis selected a "duration of dizziness ≤15 seconds" and "onset when turning over in bed" as independent predictors of DHT + BPPV with an odds ratio (95% confidence interval of 4.36 (1.18–16.19 and 10.17 (2.49–41.63, respectively. Affirmative answers to both questions yielded a likelihood ratio of 6.81 (5.11–9.10 for diagnosis of DHT + BPPV, while negative answers to both had a likelihood ratio of 0.19 (0.08–0.47.Conclusion: A "duration of dizziness ≤15 seconds" and "onset when turning over in bed" were the two most important questions among various historical features of BPPV.Keywords: benign paroxysmal positional vertigo, likelihood ratio, diagnosis, screening, prediction rules

  1. Can cadaverous pollution from environmental lead misguide to false positive results in the histochemical determination of gunshot residues? Study on cadaveric skin samples.

    Science.gov (United States)

    Boracchi, Michele; Andreola, Salvatore; Collini, Federica; Gentile, Guendalina; Maciocco, Francesca; Maghin, Francesca; Zoja, Riccardo

    2017-08-01

    Histochemical determination of lead in gunshot residues (GSR) raises the question of possible environmental contamination by heavy metals. Authors assess the specificity of the Sodium Rhodizonate Test in the search of lead derived from environmental pollution. Sodium Rhodizonate Test and 5% HCl Sodium Rhodizonate test were applied to skin samples taken from two groups of victims, whose cause of death was not related to gunshot wounds: group A included 25 corpses found in open spaces after a long time; group B included 16 corpses exhumed after a period of 11 years. The use of these histochemical tests to skin samples from these two groups did not show metal debris histochemically similar to the lead present in GSR. These tests were confirmed to be specific in highlighting the GSR coming from gunshot, without being affected by the potential environmental contamination of the heavy metal pollutants, coming from air or soil. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Beam position determination for the Test Storage Ring

    International Nuclear Information System (INIS)

    Baumann, P.

    1987-01-01

    The Test Storage Ring (TSR) for heavy ions, currently under design and construction at the Max Planck Institute for Nuclear Physics in Heidelberg, requires an extensive beam diagnostics system in order to enable it to operate without friction. This thesis concerns the beam position determination sub-system of this diagnostics system which is intended to determine the beam center of gravity of a bunched beam inside the cross section of the beam tube in a non-destructive manner. An electrostatic pickup is used to sense the location of the beam; the mode of operation of this device will be explained in detail. The signals go to a preamplifier from where they are then sent via a multiplex system to the measuring unit. This point also represents the interface to the computer system that controls the TSR. The prototype developed here was tested with the aid of a particle beam, as well as with other measurement methods. Resolutions of better than 1 mm about the center have been measured. In order to achieve or even improve such resolutions later in actual operation, it is possible to determine the properties of the preamplifiers with the aid of calibration signals and to take these into account in the course of the signal evaluation in the computer. The differences between the individual electrodes of a given pickup must also be compensated. These procedures and their associated electronic circuits are also described in this paper

  3. Positive patch test reactions to oxidized limonene: exposure and relevance.

    Science.gov (United States)

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Gimenez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2014-11-01

    R-Limonene is a common fragrance terpene found in domestic and industrial products. R-Limonene autoxidizes on air exposure, and the oxidation products can cause contact allergy. In a recent multicentre study, 5.2% (range 2.3-12.1%) of 2900 patients showed a positive patch test reaction to oxidized R-limonene. To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. Oxidized R-limonene 3.0% (containing limonene hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. Overall, exposure to products containing limonene was found and assessed as being probably relevant for the patients' dermatitis in 36% of the limonene-allergic patients. In Barcelona and Copenhagen, > 70% of the patients were judged to have had an exposure to limonene assessed as relevant. Oxidized R-limonene is a common fragrance allergen, and limonene was frequently found in the labelling on the patients' products, and assessed as relevant for the patients' dermatitis. A large number of domestic and occupational sources for contact with R-limonene were identified. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Impact of age on the false negative rate of human papillomavirus DNA test in patients with atypical squamous cells of undetermined significance.

    Science.gov (United States)

    Won, Kyu-Hee; Lee, Jae Yeon; Cho, Hye-Yon; Suh, Dong Hoon; No, Jae Hong; Kim, Yong-Beom

    2015-03-01

    Human papillomavirus (HPV) test was incorporated into the triage of lesser abnormal cervical cytologies: atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL). This study aimed to evaluate the impact of age on the efficacy of HPV testing in patients with lesser abnormal cervical cytologies. A total of 439 patients with ASCUS or LSIL were included. The association between age groups and the diagnostic performances of HPV test for high-grade cervical intraepithelial neoplasia (CIN2+) was evaluated. Median age was 44 years (range, 17 to 75 years). ASCUS was more frequently observed in older patients while LSIL was more common in younger patients (P=0.002). CIN2+ was found in 11.3% (32/284) of the ASCUS patients and 12.9% (20/155) of patients with LSIL. Older patients with ASCUS showed lower HPV infection rates (P=0.025), but not LSIL (P=0.114). However, the prevalence of CIN2+ was similar between the age groups with ASCUS or LSIL. In patients with ASCUS, the false negative rate of HPV test for CIN2+ was 6.2%. The false negative rate of the HPV test became higher with increasing of the age after the age of 50 (P=0.034). Our findings suggest that false negative rate of the HPV test for CIN2+ in ASCUS patients older than 50 years might become higher with increasing of the age. Negative HPV results in patients of the age >50 years with ASCUS should be carefully interpreted.

  5. Mandatory vaccinations in European countries, undocumented information, false news and the impact on vaccination uptake: the position of the Italian pediatric society.

    Science.gov (United States)

    Bozzola, Elena; Spina, Giulia; Russo, Rocco; Bozzola, Mauro; Corsello, Giovanni; Villani, Alberto

    2018-06-14

    High rates of vaccination coverage are important in preventing infectious diseases. Enforcing mandatory vaccinations is one of the strategies that some Countries adopted to protect the community when vaccination coverage is not satisfactory. In Italy, in 2017 vaccination against diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella became compulsory in childhood. In order to contrast vaccination policies, anti-vaccination campaigns contribute to the spread of fake news. Among them, there is the false information that Italy is the only one country with mandatory vaccination policy. Aim of our study is confronting vaccination policies in children under 18 months against among different European countries for the following vaccines: diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella. Information on policies of mandatory or recommended vaccinations of the European Countries were gathered by ECDC and compared to the Italian one. European Countries recommend or contemplate compulsory vaccines. Among them, eleven Countries (35.4%) have mandatory vaccinations for at least one out of diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella vaccine. Not only in Italy, vaccination against diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella is mandatory in children under 18 months. Other European countries adopted compulsory policies in order to prevent the spread of infectious diseases and to protect the community.

  6. Self-Reported HIV-Positive Status But Subsequent HIV-Negative Test Result Using Rapid Diagnostic Testing Algorithms Among Seven Sub-Saharan African Military Populations

    Science.gov (United States)

    2017-07-07

    analysis, data interpretation, or writing of the report. Leidos provided support in the form of salaries for JH, BRT, AGT, MBJ and JM but did not have any...have data on a QA process. The survey used for all seven partner mili- taries was based on a standardized modular survey, which assessed HIV risk... Technical considerations Technical limitations have been shown to increase false-positive HIV test results in voluntary counseling and testing centers

  7. The semantics of emotion in false memory.

    Science.gov (United States)

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  8. A cause of false positive of the whole body scanning with iodine 131: obstructive hydronephrosis; Une cause de faux-positif du balayage corps entier a l'iode 131: l'hydronephrose obstructive

    Energy Technology Data Exchange (ETDEWEB)

    Sellem, A.; Elbez, I.; Rejeb, O.; Elkadri, N.; Hammami, H. [Service de medecine nucleaire, hopital Militaire, Tunis, (Tunisia)

    2009-05-15

    The objective is to report the case of a differentiated carcinoma of the thyroid with a false positive aspect to the whole-body scanning with iodine 131 in relation with an accumulation of the tracer at the level of an obstructive appearance hydronephrosis. (N.C.)

  9. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  10. The power of extraverts: testing positive and negative mood regulation

    Directory of Open Access Journals (Sweden)

    Gonzalo Hervas

    Full Text Available Extraversion is a personality trait which has been systematically related to positive affect and well-being. One of the mechanisms that may account for these positive outcomes is the ability to regulate the responses to positive, as well as negative, moods. Prior research has found that extraverts' higher positive mood maintenance could explain their higher levels of positive affect. However, research exploring differences between extraverts and introverts in negative mood regulation has yielded mixed results. The aim of the current study was explore the role of different facets of mood regulation displayed by extraverts, ambiverts, and introverts. After been exposed to a sad vs. happy mood induction, participants underwent a mood regulation task. Extraverts and ambiverts exhibited higher positive mood regulation than introverts, but similar mood repair. Thus, this research highlights the importance of positive mood regulation in the psychological functioning of extraverts, and opens new conceptualizations for developing interventions for introverts to improve their positive mood regulation and, hence, overall positive affect and well-being.

  11. PET Study with false positive {sup 68}Ga-Dotatate caused by the presence of an accessory spleen; Estudio PET con {sup 68}Ga-Dotatate falso positivo causado por la presencia de un bazo accesorio

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago / Seccion Medicina Nuclear, Departamento Medicina, Hospital Clinico Universidad de Chile. Santiago (Chile); Jofre, Josefina; Sierralta, M. Paulina; Canessa, Jose [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago. Santiago (Chile)

    2013-05-31

    Neuroendocrine tumors with somatostatin receptor expression are suitable for imaging with somatostatin analogues. {sup 68}Ga-labeled peptides are useful for the diagnosis, staging and assessment of therapeutic response of these tumors. However, for a correct interpretation it is necessary to know the normal biodistribution of somatostatin receptors in the body. Asymmetric adrenal uptake may be a normal variant to cause confusion, or an accessory or ectopic spleen can lead to a false positive result. We report a case of asymmetric adrenal uptake which was correctly considered as a normal variant, but an accessory spleen caused the false impression of being a metastasis from a previously resected primary carcinoid tumor.

  12. False-positive defects in technetium-99m sestamibi myocardial single-photon emission tomography in healthy athletes with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Bartram, P.; Hanel, B.; Gustafsson, F.; Mortensen, J.; Hesse, B.; Toft, J.; Ali, S.

    1998-01-01

    Exercise ECG and myocardial single-photon emission tomography (SPET) are fundamental in the non-invasive evaluation of patients suspected of having coronary artery disease (CAD). The purpose of the present study was to investigate the influence of physiological left ventricular hypertrophy (LVH) on myocardial sestamibi SPET in healthy young and old athletes. Eighteen young male elite athletes (ten rowers, five power/weight lifters and three triathletes) and 14 well-trained elderly rowers were studied. All underwent a bicycle test as part of a 2-day sestamibi SPET protocol. Attenuation correction was not performed. The studies were evaluated visually and quantitatively analysed by the CEqual program with its reference files and with a file from a local non-athletic age-matched population. Echocardiographic LVH was an inclusion criterion in the young athletes. Exercise ECG was normal in all subjects. In at least three of the young athletes a reversible defect was observed by visual analysis. On quantitative analysis one-third of the young athletes had ''significant'' (>10 pixels) defects compared with both the local reference base and the CEqual reference population. Nearly all defects were found in the anterior or inferior wall. The remaining subjects, including all old rowers, had normal SPET findings. Anterior and inferior wall defects are so common in healthy athletes with physiological LVH that the specificity of myocardial SPET, in contrast to exercise ECG, seems to be too low for evaluation of chest pain in this group. The mechanism of anterior and inferior defects may be related to hot spots (papillary muscles?) in the lateral wall. The specificity of SPET is maintained in athletes without LVH. (orig.)

  13. Just Diagnosed: Next Steps After Testing Positive for HIV

    Science.gov (United States)

    ... recommending an HIV regimen. Testing for sexually transmitted diseases (STDs) Coinfection with another STD can cause HIV infection to advance faster and increase the risk of HIV transmission to a sexual partner. STD testing makes it possible to detect ...

  14. HAMS: High-Affinity Mass Spectrometry Screening. A High-Throughput Screening Method for Identifying the Tightest-Binding Lead Compounds for Target Proteins with No False Positive Identifications.

    Science.gov (United States)

    Imaduwage, Kasun P; Go, Eden P; Zhu, Zhikai; Desaire, Heather

    2016-11-01

    A major challenge in drug discovery is the identification of high affinity lead compounds that bind a particular target protein; these leads are typically identified by high throughput screens. Mass spectrometry has become a detection method of choice in drug screening assays because the target and the ligand need not be modified. Label-free assays are advantageous because they can be developed more rapidly than assays requiring labels, and they eliminate the risk of the label interfering with the binding event. However, in commonly used MS-based screening methods, detection of false positives is a major challenge. Here, we describe a detection strategy designed to eliminate false positives. In this approach, the protein and the ligands are incubated together, and the non-binders are separated for detection. Hits (protein binders) are not detectable by MS after incubation with the protein, but readily identifiable by MS when the target protein is not present in the incubation media. The assay was demonstrated using three different proteins and hundreds of non-inhibitors; no false positive hits were identified in any experiment. The assay can be tuned to select for ligands of a particular binding affinity by varying the quantity of protein used and the immobilization method. As examples, the method selectively detected inhibitors that have K i values of 0.2 μM, 50 pM, and 700 pM. These findings demonstrate that the approach described here compares favorably with traditional MS-based screening methods. Graphical Abstract ᅟ.

  15. Prevalence of positive tuberculin skin test and associated factors ...

    African Journals Online (AJOL)

    different from one derived from mixture analysis [46.3%(95% Bayesian credibility interval 36.5%-55.8%)]. Positive ... Health Organization (WHO) report of the World's top. 22 high ..... World re- port 2009. WHO/HTM/TB/2009.411. Geneva: World.

  16. Evaluation of liver function tests of HIV positive patients on ...

    African Journals Online (AJOL)

    Liver enzymes-alanine and aspartate aminotransferases and alkaline phosphatase (AST, ALT and ALP), bilirubin and serum proteins were determined using standard laboratory methods and these parameters were used to evaluate the liver function of human immunodeficiency virus (HIV)- positive patients receiving ...

  17. A fast numerical test of multivariate polynomial positiveness with applications

    Czech Academy of Sciences Publication Activity Database

    Augusta, Petr; Augustová, Petra

    2018-01-01

    Roč. 54, č. 2 (2018), s. 289-303 ISSN 0023-5954 Institutional support: RVO:67985556 Keywords : stability * multidimensional systems * positive polynomials * fast Fourier transforms * numerical algorithm Subject RIV: BC - Control Systems Theory OBOR OECD: Automation and control systems Impact factor: 0.379, year: 2016 https://www.kybernetika.cz/content/2018/2/289/paper.pdf

  18. Relevance of positive patch-test reactions to fragrance mix.

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.; Kruyswijk, M.R.; Zuuren, E.J. van; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; Valk, P.G.M. van der

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  19. Relevance of positive patch-test reactions to fragrance mix

    NARCIS (Netherlands)

    Devos, S.A.; Constandt, L.; Tupker, R.A.; Noz, K.C.; Lucker, G.P.H.; Bruynzeel, D.P.; Schuttelaar, M.L.A.; Kruyswijk, M.R.J.; van Zuuren, E.J.; Vink, J.; Coenraads, P.J.; Kiemeney, L.A.L.M.; van der Valk, P.G.M.

    2008-01-01

    BACKGROUND: Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong

  20. Modeling Kepler Transit Light Curves as False Positives: Rejection of Blend Scenarios for Kepler-9, and Validation of Kepler-9 d, a Super-Earth-Size Planet in a Multiple System

    Science.gov (United States)

    Torres, Guillermo; Fressin, Francois; Batalha, Natalie M.; Borucki, William J.; Brown, Timothy M.; Bryson, Stephen T.; Buchhave, Lars A.; Charbonneau, David; Ciardi, David R.; Dunham, Edward W.; hide

    2011-01-01

    Light curves from the Kepler Mission contain valuable information on the nature of the phenomena producing the transit-like signals. To assist in exploring the possibility that they are due to an astrophysical false positive we describe a procedure (BLENDER) to model the photometry in terms of a blend rather than a planet orbiting a star. A blend may consist of a background or foreground eclipsing binary (or star-planet pair) whose eclipses are attenuated by the light of the candidate and possibly other stars within the photometric aperture. We apply BLENDER to the case of Kepler-9 (KIC 3323887), a target harboring two previously confirmed Saturn-size planets (Kepler-9 b and Kepler-9 c) showing transit timing variations, and an additional shallower signal with a 1.59 day period suggesting the presence of a super-Earth-size planet. Using BLENDER together with constraints from other follow-up observations we are able to rule out all blends for the two deeper signals and provide independent validation of their planetary nature. For the shallower signal, we rule out a large fraction of the false positives that might mimic the transits. The false alarm rate for remaining blends depends in part (and inversely) on the unknown frequency of small-size planets. Based on several realistic estimates of this frequency, we conclude with very high confidence that this small signal is due to a super-Earth-size planet (Kepler-9 d) in a multiple system, rather than a false positive. The radius is determined to be 1.64(exp)(sub-14),R, and current spectroscopic observations are as yet insufficient to establish its mass.

  1. Underpowered samples, false negatives, and unconscious learning.

    Science.gov (United States)

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  2. Predictors for benign paroxysmal positional vertigo with positive Dix?Hallpike test

    OpenAIRE

    Noda, Kazutaka; Ikusaka, Masatomi; Ohira, Yoshiyuki; Takada, Toshihiko; Tsukamoto, Tomoko

    2011-01-01

    Kazutaka Noda, Masatomi Ikusaka, Yoshiyuki Ohira, Toshihiko Takada, Tomoko TsukamotoDepartment of General Medicine, Chiba University Hospital, Chiba, JapanObjective: Patient medical history is important for making a diagnosis of causes of dizziness, but there have been no studies on the diagnostic value of individual items in the history. This study was performed to identify and validate useful questions for suspecting a diagnosis of benign paroxysmal positional vertigo (BPPV).Methods: Constr...

  3. Too Good to be False : Nonsignificant Results Revisited

    NARCIS (Netherlands)

    Hartgerink, Chris H J; Wicherts, Jelte M.; Van Assen, M. A. L. M.

    2017-01-01

    Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST) is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant

  4. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investiga...

  5. United States position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Johnson, R.P.

    1983-01-01

    The first Specialists' Meeting on sodium fire technology sponsored by the International Working Group on Fast Reactors (IWGFR) was held in Richland, Washington in 1972. The group concluded that the state-of-technology at that time was inadequate to support the growing LMFBR industry. During the second IWGFR Specialists' Meeting on sodium fires, held in Cadarache, France in 1978, a large quantity of technical information was exchanged and areas were identified where additional work was needed. Advances in several important areas of sodium fire technology have been made in the United States since that time, including improved computer codes, design of a sodium fire protection system for the CRBRP, measurement of water release from heated concrete, and testing and modeling of the sodium-concrete reaction. Research in the U.S. related to sodium fire technology is performed chiefly at the Energy Systems Group of Rockwell International (including Atomics International), the Hanford Engineering Development Laboratory (HEDL), and the Sandia National Laboratories (SNL). The work at the first two laboratories is sponsored by the U.S. Department of Energy, while that at the latter is sponsored by the U.S. Nuclear Regulatory Commission. Various aspects of sodium fire related work is also performed at several other laboratories. The current status of sodium fire technology in the U.S. is summarized in this report

  6. Positive results of serological tests for syphilis in pregnancy – diagnostic and therapeutic problems, report of two cases

    Directory of Open Access Journals (Sweden)

    Marta Koper

    2015-06-01

    Full Text Available Introduction. Undiagnosed and untreated syphilis in pregnancy may result in subsequent complications: early fetal loss, stillbirth, low birth weight of infants and newborns with congenital syphilis. Objective. To analyze diagnostic and therapeutic dilemmas of positive results of serological tests for syphilis (STS in pregnancy. Case reports. We present two cases of pregnant women, hospitalized in our department due to positive results of serological tests for syphilis, performed during the antenatal visit. On the basis of patients' history, physical examination and STS results, early latent syphilis was diagnosed in the first patient; biological false positive reactions were considered in the second one. Both patients received procaine penicillin treatment. Conclusions. Screening for syphilis in pregnancy as a part of antenatal care and appropriate treatment with penicillin are the most effective interventions to prevent complications of syphilis in pregnancy. It is also important to adapt modern European Guidelines for management of syphilis to Polish conditions.

  7. Characterizing the Joint Effect of Diverse Test-Statistic Correlation Structures and Effect Size on False Discovery Rates in a Multiple-Comparison Study of Many Outcome Measures

    Science.gov (United States)

    Feiveson, Alan H.; Ploutz-Snyder, Robert; Fiedler, James

    2011-01-01

    In their 2009 Annals of Statistics paper, Gavrilov, Benjamini, and Sarkar report the results of a simulation assessing the robustness of their adaptive step-down procedure (GBS) for controlling the false discovery rate (FDR) when normally distributed test statistics are serially correlated. In this study we extend the investigation to the case of multiple comparisons involving correlated non-central t-statistics, in particular when several treatments or time periods are being compared to a control in a repeated-measures design with many dependent outcome measures. In addition, we consider several dependence structures other than serial correlation and illustrate how the FDR depends on the interaction between effect size and the type of correlation structure as indexed by Foerstner s distance metric from an identity. The relationship between the correlation matrix R of the original dependent variables and R, the correlation matrix of associated t-statistics is also studied. In general R depends not only on R, but also on sample size and the signed effect sizes for the multiple comparisons.

  8. Coinfection of hepatitis A virus genotype IA and IIIA complicated with autoimmune hemolytic anemia, prolonged cholestasis, and false-positive immunoglobulin M anti-hepatitis E virus: a case report.

    Science.gov (United States)

    Kim, Hee Sup; Jeong, Sook Hyang; Jang, Je Hyuck; Myung, Hyung Joon; Kim, Jin Wook; Bang, Soo Mee; Song, Sang Hoon; Kim, Haeryoung; Yun, Hae Sun

    2011-12-01

    A 37-year-old male presented with fever and jaundice was diagnosed as hepatitis A complicated with progressive cholestasis and severe autoimmune hemolytic anemia. He was treated with high-dose prednisolone (1.5 mg/kg), and eventually recovered. His initial serum contained genotype IA hepatitis A virus (HAV), which was subsequently replaced by genotype IIIA HAV. Moreover, at the time of development of hemolytic anemia, he became positive for immunoglobulin M (IgM) anti-hepatitis E virus (HEV). We detected HAV antigens in the liver biopsy specimen, while we detected neither HEV antigen in the liver nor HEV RNA in his serum. This is the first report of hepatitis A coinfected with two different genotypes manifesting with autoimmune hemolytic anemia, prolonged cholestasis, and false-positive IgM anti-HEV.

  9. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    Science.gov (United States)

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  10. Perfectionism, Performance, and State Positive Affect and Negative Affect after a Classroom Test

    Science.gov (United States)

    Flett, Gordon L.; Blankstein, Kirk R.; Hewitt, Paul L.

    2009-01-01

    The current study examined the associations among trait dimensions of perfectionism, test performance, and levels of positive and negative affect after taking a test. A sample of 92 female university students completed the Multidimensional Perfectionism Scale one week prior to an actual class test. Measures of positive affect and negative affect…

  11. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.

    Science.gov (United States)

    Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten

    According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  12. Design, building and test of one prototype and four final position sensor assemblies: Hall effect position sensors

    Science.gov (United States)

    1976-01-01

    This report covers the development of a three channel Hall effect position sensing system for the commutation of a three phase dc torquer motor. The effort consisted of the evaluation, modification and re-packaging of a commercial position sensor and the design of a target configuration unique to this application. The resulting design meets the contract requirements and, furthermore, the test results indicate not only the practicality and versatility of the design, but also that there may be higher limits of resolution and accuracy achievable.

  13. For Men: A Positive Zika Virus Test, What Does It Mean for Me?

    Science.gov (United States)

    CDC’s Response to Zika FOR MEN: A POSITIVE ZIKA VIRUS TEST What does it mean for me? You’ ... Zika test result, which means that you have Zika virus. Zika is spread through mosquito bites and through ...

  14. False-positive uptake on 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) in oncological imaging

    International Nuclear Information System (INIS)

    Culverwell, A.D.; Scarsbrook, A.F.; Chowdhury, F.U.

    2011-01-01

    With the increasing utilization of integrated positron-emission tomography/computed tomography (PET/CT) using the glucose analogue 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) in oncological imaging, it is important for radiologists and nuclear medicine physicians to be aware that FDG uptake is not specific for malignancy, as many different physiological variants and benign pathological conditions can also exhibit increased glucose metabolism. Such false-positive FDG uptake often arises outside the area of primary interest and may mimic malignant disease, thereby confounding accurate interpretation of PET/CT studies. With the use of illustrative clinical cases, this article will provide a systematic overview of potential interpretative pitfalls and illustrate how such unexpected findings can be appropriately evaluated.

  15. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B [College of Medicine, Kyungpook National University, Daegu (Korea, Republic of)

    2004-07-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35{+-}10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52{+-}10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  16. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B

    2004-01-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35±10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52±10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  17. Psychoactive drugs and false memory: comparison of dextroamphetamine and delta-9-tetrahydrocannabinol on false recognition

    Science.gov (United States)

    Ballard, Michael E.; Gallo, David A.; de Wit, Harriet

    2014-01-01

    Rationale Several psychoactive drugs are known to influence episodic memory. However, these drugs’ effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Objectives Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ9-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger–McDermott (DRM) illusion. Methods Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. Results As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs’ effects on true memory were positively correlated with their effects on false memory. Conclusions Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories. PMID:21647577

  18. Psychoactive drugs and false memory: comparison of dextroamphetamine and δ-9-tetrahydrocannabinol on false recognition.

    Science.gov (United States)

    Ballard, Michael E; Gallo, David A; de Wit, Harriet

    2012-01-01

    Several psychoactive drugs are known to influence episodic memory. However, these drugs' effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ(9)-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger-McDermott (DRM) illusion. Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs' effects on true memory were positively correlated with their effects on false memory. Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories.

  19. Histamine release positive test associates with disease remission in chronic spontaneous urticaria

    DEFF Research Database (Denmark)

    Berti, A; Yacoub, M R; Skov, Per Stahl

    2017-01-01

    the correlations between HR test results and demographic features, quality of life, disease activity, clinical course, and autologous serum and plasma skin tests (ASST and APST). Results. All patients with positive HR test (9/9, 100%) had a more severe disease activity at onset (urticaria activity score, UAS > 2......Summary: Background. Histamine release (HR) test has previously been shown to predict the presence of endogenous histamine-releasing factors in chronic spontaneous urticaria (CSU). Objectives and methods. Twenty CSU patients unresponsive to antihistamine treatment were enrolled in order to evaluate...... with a positive HR test had a significant reduction of disease activity (p = 0.003) whereas patients with a negative HR test did not (p > 0.05), leading to disease remission and antihistamine treatment withdrawal in 67% (6/9) of positive HR test patients versus 18% (2/11) of negative HR test patients (p = 0...

  20. Association between positive patch tests to epoxy resin and fragrance mix I ingredients

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Christensen, Lars Porskjaer; Vølund, Aage

    2009-01-01

    and possibly reproduce this association with the use of TRUE((R)) test data and supplementary tests with fragrance mix ingredients from the Department of Dermatology, Odense University Hospital. MATERIALS AND METHODS: Six thousand one hundred and fifteen consecutive eczema patients tested from 1995 to 2007......BACKGROUND: Both epoxy resin (diglycidyl ether of bisphenol A) and fragrance mix I are included in the European baseline series of contact allergens. A significant association between positive reactions to epoxy resin and fragrance mix has been reported by others. OBJECTIVE: To investigate...... were included, and test results from all patients tested with fragrance mix ingredients were analysed. RESULTS: One hundred and forty-five (2.4%) were positive to epoxy resin and 282 (4.6%) were positive to fragrance mix I. Nineteen were positive to both giving an odds ratio of 3.3, which...

  1. Preliminary performance test of control rod position indicator for ballscrew type CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. H.; Hu, H.; Lee, J. S.; Kim, J. I.

    2003-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The prototype of control rod position indicator having the high performance for the ballscrew type CEDM was developed on the basis of RSPT technology identified through the survey. The characteristics of control rod position indicator was defined and documented through design procedure and preliminary performance test

  2. Systemic True False

    African Journals Online (AJOL)

    Preferred Customer

    ):. (a). (b). (c). (d). Answer: True systemics are (b & c); False Systemics (a & d). For more examples, see (10 and 11). Na2O2. NaCl. Na. HCl heat /excess. (O). 300°C electrolysis. (molten). NaOH. NaCl. Na. HCl. H2O electrolysis. (solution). NaCl.

  3. Voting experiments: Bandwagon voting or false-consensus effect?

    OpenAIRE

    Ivo Bischoff; Henrik Egbert

    2008-01-01

    In an experiment designed to test for expressive voting, Tyran (JPubEc 2004) found a strong positive correlation between the participants' approval for a proposal to donate money for charity and their expected approval rate for fellow voters. This phenomenon can be due to bandwagon voting or a false consensus effect. The social science literature reports both effects for voting decisions. Replicating Tyran's experiment and adding new treatments, we provide evidence for a false consensus effec...

  4. Clostridium difficile Testing Algorithm: Is There a Difference in Patients Who Test Positive by Enzyme Immunoassay vs. Those Who Only Test Positive by Nucleic Acid Amplification Methodology?

    OpenAIRE

    Polak, Jonathan; Odili, Ogheneruona; Craver, Mary Ashleigh; Mayen, Anthony; Purrman, Kyle; Rahman, Asem; Sang, Charlie Joseph; Cook, Paul P

    2017-01-01

    Abstract Background Testing for Clostridium difficile infection (CDI) commonly involves checking for the presence of toxins A and B by enzyme immunoassay (EIA) or nucleic acid amplification (NAA). The former is very specific, but not very sensitive. The latter is very sensitive. Beginning in 2011, our hospital incorporated an algorithm that involved testing liquid stool specimens for glutamate dehydrogenase (GDH) and toxin by EIA. For discrepant results, the stool specimen was tested for the ...

  5. Sleep loss produces false memories.

    Directory of Open Access Journals (Sweden)

    Susanne Diekelmann

    Full Text Available People sometimes claim with high confidence to remember events that in fact never happened, typically due to strong semantic associations with actually encoded events. Sleep is known to provide optimal neurobiological conditions for consolidation of memories for long-term storage, whereas sleep deprivation acutely impairs retrieval of stored memories. Here, focusing on the role of sleep-related memory processes, we tested whether false memories can be created (a as enduring memory representations due to a consolidation-associated reorganization of new memory representations during post-learning sleep and/or (b as an acute retrieval-related phenomenon induced by sleep deprivation at memory testing. According to the Deese, Roediger, McDermott (DRM false memory paradigm, subjects learned lists of semantically associated words (e.g., "night", "dark", "coal",..., lacking the strongest common associate or theme word (here: "black". Subjects either slept or stayed awake immediately after learning, and they were either sleep deprived or not at recognition testing 9, 33, or 44 hours after learning. Sleep deprivation at retrieval, but not sleep following learning, critically enhanced false memories of theme words. This effect was abolished by caffeine administration prior to retrieval, indicating that adenosinergic mechanisms can contribute to the generation of false memories associated with sleep loss.

  6. Helminths and skewed cytokine profiles increase tuberculin skin test positivity in Warao Amerindians

    NARCIS (Netherlands)

    Verhagen, L. M.; Hermans, P. W. M.; Warris, A.; de Groot, R.; Maes, M.; Villalba, J. A.; del Nogal, B.; van den Hof, S.; Mughini Gras, L.; van Soolingen, D.; Pinelli, E.; de Waard, J. H.

    2012-01-01

    The immune regulatory mechanisms involved in the acquisition of Mycobacterium tuberculosis infection in children are largely unknown. We investigated the influence of parasitic infections, malnutrition and plasma cytokine profiles on tuberculin skin test (TST) positivity in Warao Amerindians in

  7. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  8. A CLASS OF DISTRIBUTION-FREE TESTS FOR INDEPENDENCE AGAINST POSITIVE QUADRANT DEPENDENCE

    Directory of Open Access Journals (Sweden)

    Parameshwar V Pandit

    2014-02-01

    Full Text Available A class of distribution-free tests based on convex combination of two U-statistics is considered for testing independence against positive quadrant dependence. The class of tests proposed by Kochar and Gupta (1987 and Kendall’s test are members of the proposed class. The performance of the proposed class is evaluated in terms of Pitman asymptotic relative efficiency for Block- Basu (1974 model and Woodworth family of distributions. It has been observed that some members of the class perform better than the existing tests in the literature.  Unbiasedness and consistency of the proposed class of tests have been established.

  9. A High-Throughput Mass Spectrometry Assay Coupled with Redox Activity Testing Reduces Artifacts and False Positives in Lysine Demethylase Screening.

    Science.gov (United States)

    Wigle, Tim J; Swinger, Kerren K; Campbell, John E; Scholle, Michael D; Sherrill, John; Admirand, Elizabeth A; Boriack-Sjodin, P Ann; Kuntz, Kevin W; Chesworth, Richard; Moyer, Mikel P; Scott, Margaret Porter; Copeland, Robert A

    2015-07-01

    Demethylation of histones by lysine demethylases (KDMs) plays a critical role in controlling gene transcription. Aberrant demethylation may play a causal role in diseases such as cancer. Despite the biological significance of these enzymes, there are limited assay technologies for study of KDMs and few quality chemical probes available to interrogate their biology. In this report, we demonstrate the utility of self-assembled monolayer desorption/ionization (SAMDI) mass spectrometry for the investigation of quantitative KDM enzyme kinetics and for high-throughput screening for KDM inhibitors. SAMDI can be performed in 384-well format and rapidly allows reaction components to be purified prior to injection into a mass spectrometer, without a throughput-limiting liquid chromatography step. We developed sensitive and robust assays for KDM1A (LSD1, AOF2) and KDM4C (JMJD2C, GASC1) and screened 13,824 compounds against each enzyme. Hits were rapidly triaged using a redox assay to identify compounds that interfered with the catalytic oxidation chemistry used by the KDMs for the demethylation reaction. We find that overall this high-throughput mass spectrometry platform coupled with the elimination of redox active compounds leads to a hit rate that is manageable for follow-up work. © 2015 Society for Laboratory Automation and Screening.

  10. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests

    NARCIS (Netherlands)

    Emmerzaal, A.; Wit, de J.J.; Dijkstra, T.; Bakker, D.; Ziiderveld, van F.G.

    2002-01-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the

  11. The champagne toast position isolates the supraspinatus better than the Jobe test: an electromyographic study of shoulder physical examination tests.

    Science.gov (United States)

    Chalmers, Peter N; Cvetanovich, Gregory L; Kupfer, Noam; Wimmer, Markus A; Verma, Nikhil N; Cole, Brian J; Romeo, Anthony A; Nicholson, Gregory P

    2016-02-01

    While Jobe's test is widely used, it does not isolate supraspinatus activity. Our purpose was to examine the electromyographic (EMG) activity within the supraspinatus and deltoid with resisted abduction to determine the shoulder position that best isolates the activity of the supraspinatus. We performed EMG analysis of the supraspinatus, anterior head of the deltoid, and middle head of the deltoid in 10 normal volunteers. We measured EMG activity during resisted shoulder abduction in the scapular plane to both manual resistance and a standardized load in varying degrees of abduction and rotation. To determine which position best isolates supraspinatus activity, the ratio of supraspinatus to deltoid activity (S:D) was calculated for each position. Results were analyzed with a repeated-measures analysis of variance with Bonferroni correction. The posterior deltoid was excluded as it serves mostly to extend and externally rotate. Our study confirmed Jobe's findings of maximal supraspinatus activity at 90° of abduction. However, decreasing abduction significantly increased S:D for both resisted manual testing and testing against a standardized load (P = .002 and .001, respectively). The greatest S:D ratio (4.6 ± 3.4 for standardized load testing) was seen at the "champagne toast" position, i.e., 30° of abduction, mild external rotation, 30° of flexion, and 90° of elbow flexion. The smallest ratio (0.8 ± 0.6) was seen at Jobe's position. Testing of abduction strength in the champagne toast position, i.e., 30° of abduction, mild external rotation, and 30° of flexion, better isolates the activity of the supraspinatus from the deltoid than Jobe's "empty can" position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Impact of age on the false negative rate of human papillomavirus DNA test in patients with atypical squamous cells of undetermined significance

    OpenAIRE

    Won, Kyu-Hee; Lee, Jae Yeon; Cho, Hye-Yon; Suh, Dong Hoon; No, Jae Hong; Kim, Yong-Beom

    2015-01-01

    Objective Human papillomavirus (HPV) test was incorporated into the triage of lesser abnormal cervical cytologies: atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL). This study aimed to evaluate the impact of age on the efficacy of HPV testing in patients with lesser abnormal cervical cytologies. Methods A total of 439 patients with ASCUS or LSIL were included. The association between age groups and the diagnostic performances of ...

  13. False-negative contrast-enhanced spectral mammography: use of more than one imaging modality and application of the triple test avoids misdiagnosis.

    Science.gov (United States)

    Taylor, Donna; O'Hanlon, Susan; Latham, Bruce

    2017-03-31

    A 50-year-old woman presented with chest tenderness. On examination, both breasts were lumpy. Bilateral mammography showed heterogeneously dense parenchyma, with possible stromal distortion laterally on the right at the 0900 position. On ultrasound (US), a corresponding 13×9×10 mm irregular hypoechoic mass with internal vascularity was noted and both breasts had a complex heterogeneous fibroglandular background pattern. US-guided core biopsy with marker clip insertion was performed with the diagnosis of a grade 2 invasive ductal carcinoma (IDC). In view of the parenchymal pattern on mammography and US, contrast-enhanced spectral mammography (CESM) was performed for local staging. Mild background enhancement was noted, but there was no enhancement at the lesion site. The patient elected to have bilateral mastectomies and sentinel node biopsies. Final histopathology showed a node negative 11 mm grade 2 oestrogen and progesterone receptor positive, IDC. 2017 BMJ Publishing Group Ltd.

  14. Evidence Based Medicine; Positive and Negative Likelihood Ratios of Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Alireza Baratloo

    2015-10-01

    Full Text Available In the previous two parts of educational manuscript series in Emergency, we explained some screening characteristics of diagnostic tests including accuracy, sensitivity, specificity, and positive and negative predictive values. In the 3rd  part we aimed to explain positive and negative likelihood ratio (LR as one of the most reliable performance measures of a diagnostic test. To better understand this characteristic of a test, it is first necessary to fully understand the concept of sensitivity and specificity. So we strongly advise you to review the 1st part of this series again. In short, the likelihood ratios are about the percentage of people with and without a disease but having the same test result. The prevalence of a disease can directly influence screening characteristics of a diagnostic test, especially its sensitivity and specificity. Trying to eliminate this effect, LR was developed. Pre-test probability of a disease multiplied by positive or negative LR can estimate post-test probability. Therefore, LR is the most important characteristic of a test to rule out or rule in a diagnosis. A positive likelihood ratio > 1 means higher probability of the disease to be present in a patient with a positive test. The further from 1, either higher or lower, the stronger the evidence to rule in or rule out the disease, respectively. It is obvious that tests with LR close to one are less practical. On the other hand, LR further from one will have more value for application in medicine. Usually tests with 0.1 < LR > 10 are considered suitable for implication in routine practice.

  15. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy

    DEFF Research Database (Denmark)

    Tannert, Line Kring; Mørtz, Charlotte G; Skov, Per Stahl

    2017-01-01

    INTRODUCTION: According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. OBJECTIVE: To investigate the clinical relevance...... of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. METHODS: A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged......-IgE measured (T0), and then skin tested and had s-IgE measured 4 weeks later (T1). RESULTS: Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T0. Positive ST result or positive s-IgE alone did not predict...

  16. Studies on the prevalence of leishmanin skin test positivity in the Baringo District, Rift Valley, Kenya

    NARCIS (Netherlands)

    Schaefer, K. U.; Kurtzhals, J. A.; Kager, P. A.; Gachihi, G. S.; Gramiccia, M.; Kagai, J. M.; Sherwood, J. A.; Muller, A. S.

    1994-01-01

    The leishmanin skin test (LST) was applied in 26 clusters of an average of 97 individuals in Baringo District, Kenya. These clusters were centered around recent cases of visceral leishmaniasis (VL). Of 2,411 individuals tested, 254 (10.5%, 155 males and 99 females) had a positive reaction. Among

  17. Latent tuberculosis in HIV positive, diagnosed by the M. tuberculosis specific interferon-gamma test

    DEFF Research Database (Denmark)

    Brock, Inger; Ruhwald, Morten; Lundgren, Bettina

    2006-01-01

    Although tuberculosis (TB) is a minor problem in Denmark, severe and complicated cases occur in HIV positive. Since the new M. tuberculosis specific test for latent TB, the QuantiFERON-TB In-Tube test (QFT-IT) became available the patients in our clinic have been screened for the presence of latent...

  18. Latent tuberculosis in HIV positive, diagnosed by the M. tuberculosis specific interferon-gamma test

    DEFF Research Database (Denmark)

    Brock, Inger; Ruhwald, Morten; Lundgren, Bettina

    2006-01-01

    BACKGROUND: Although tuberculosis (TB) is a minor problem in Denmark, severe and complicated cases occur in HIV positive. Since the new M. tuberculosis specific test for latent TB, the QuantiFERON-TB In-Tube test (QFT-IT) became available the patients in our clinic have been screened...

  19. Group Systematic Desensitization Versus Covert Positive Reinforcement in the Reduction of Test Anxiety

    Science.gov (United States)

    Kostka, Marion P.; Galassi, John P.

    1974-01-01

    The study compared modified versions of systematic desensitization and covert positive reinforcement to a no-treatment control condition in the reduction of test anxiety. On an anagrams performance test, the covert reinforcement and control groups were superior to the desensitization group. (Author)

  20. Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence.

    Science.gov (United States)

    Lantos, Paul M; Branda, John A; Boggan, Joel C; Chudgar, Saumil M; Wilson, Elizabeth A; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G; Nigrovic, Lise E

    2015-11-01

    Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%-28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%-4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  1. Baryogenesis in false vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Yuta [KEK Theory Center, IPNS, KEK, Tsukuba, Ibaraki (Japan); Yamada, Masatoshi [Kanazawa University, Institute for Theoretical Physics, Kanazawa (Japan)

    2017-09-15

    The null result in the LHC may indicate that the standard model is not drastically modified up to very high scales, such as the GUT/string scale. Having this in the mind, we suggest a novel leptogenesis scenario realized in the false vacuum of the Higgs field. If the Higgs field develops a large vacuum expectation value in the early universe, a lepton number violating process is enhanced, which we use for baryogenesis. To demonstrate the scenario, several models are discussed. For example, we show that the observed baryon asymmetry is successfully generated in the standard model with higher-dimensional operators. (orig.)

  2. O método da falsa posição na história e na educação matemática The false position method in history and in mathematics education

    Directory of Open Access Journals (Sweden)

    Cleide Farias de Medeiros

    2004-12-01

    Full Text Available Este texto coloca em uma perspectiva histórica o tratamento algébrico precoce que, costumeiramente, é dedicado ao ensino elementar da Aritmética. Defendendo que um tal tratamento algébrico precoce carrega vários pontos negativos para a formação do educando, o texto discute o "método da falsa posição" como uma alternativa viável para um tal ensino introdutório. Apontando as raízes históricas de tal método, o texto procura evidenciar as origens, aplicações e várias formas de visualizar este procedimento iterativo, desde a manipulação de materiais concretos, passando por aplicações geométricas, até atingir o Cálculo Numérico, como um dos procedimentos iterativos na resolução de equações lineares. Uma das conclusões é que, embora não seja o referido método, em sua forma mais simples, nenhum substitutivo para a resolução algébrica simbólica e moderna de equações e de sistemas de equações, ele se constitui certamente em um precioso trampolim para iniciarmos o salto em direção a um estudo mais formalizado. Particularmente, o método da falsa posição revela-se uma utilíssima ferramenta pedagógica na Educação Matemática, principalmente quando vinculado às suas origens históricas, suas abordagens concretas iniciais e suas associações com a Geometria e a Geometria Analítica.This text is a historical perspective on the early algebraic approach that is usually applied to the elementary teaching of Arithmetic. By arguing that such an initial algebraic treatment contains several drawbacks for elementary education, the ‘false position method' is discussed and is presented as a viable alternative for such introductory teaching. By pointing out the historical roots of the method, the text tries to make clear several ways of visualising this iterative procedure. This is done by incorporating the use of manipulatives and geometrical applications as well as the use of numerical calculus as an iterative

  3. A prospective study of the psychosocial impact of a positive Chlamydia trachomatis laboratory test.

    Science.gov (United States)

    Gottlieb, Sami L; Stoner, Bradley P; Zaidi, Akbar A; Buckel, Christina; Tran, Molly; Leichliter, Jami S; Berman, Stuart M; Markowitz, Lauri E

    2011-11-01

    Few data exist on potential harms of chlamydia screening. We assessed the psychosocial impact of receiving a positive Chlamydia trachomatis test result. We prospectively studied women ≥16 years of age undergoing chlamydia testing in 2 Midwestern family planning clinics. We surveyed women at baseline and about 1 month after receiving test results, using 9 validated psychosocial scales/subscales and chlamydia-specific questions. Changes in scale scores were calculated for each woman. Mean percent changes in scores for chlamydia-positive and -negative women were compared using a t test. We enrolled 1807 women (response rate, 84%). Of the 1688 women with test results, 149 (8.8%) tested positive. At follow-up, chlamydia-positive women (n = 71) had a 75% increase in anxiety about sexual aspects of their life on the Multidimensional Sexual Self-Concept Questionnaire (P < 0.001), significantly greater than the 26% increase among 280 randomly selected chlamydia-negative women (P = 0.02). There were no differences for the other 8 scales/subscales, including general measures of anxiety, depression, and self-esteem. Chlamydia-positive women were more likely than chlamydia-negative women to be "concerned about chlamydia" (80% vs. 40%, P < 0.001) and to report breaking up with a main partner (33% vs. 11%, P < 0.001) at follow-up. Women testing positive reported a range of chlamydia-specific concerns. Chlamydia-positive women had significant increases in anxiety about sex and concern about chlamydia, but did not have marked changes in more general measures of psychosocial well-being about 1 month after diagnosis. Chlamydia diagnoses were associated with some disruption of relationships with main partners. Chlamydia-specific concerns may guide counseling messages to minimize psychosocial impact.

  4. Detection test of wireless network signal strength and GPS positioning signal in underground pipeline

    Science.gov (United States)

    Li, Li; Zhang, Yunwei; Chen, Ling

    2018-03-01

    In order to solve the problem of selecting positioning technology for inspection robot in underground pipeline environment, the wireless network signal strength and GPS positioning signal testing are carried out in the actual underground pipeline environment. Firstly, the strength variation of the 3G wireless network signal and Wi-Fi wireless signal provided by China Telecom and China Unicom ground base stations are tested, and the attenuation law of these wireless signals along the pipeline is analyzed quantitatively and described. Then, the receiving data of the GPS satellite signal in the pipeline are tested, and the attenuation of GPS satellite signal under underground pipeline is analyzed. The testing results may be reference for other related research which need to consider positioning in pipeline.

  5. False memories and confabulation.

    Science.gov (United States)

    Johnson, M K; Raye, C L

    1998-04-01

    Memory distortions range from the benign (thinking you mailed a check that you only thought about mailing), to the serious (confusing what you heard after a crime with what you actually saw), to the fantastic (claiming you piloted a spaceship). We review theoretical ideas and empirical evidence about the source monitoring processes underlying both true and false memories. Neuropsychological studies show that certain forms of brain damage (such as combined frontal and medial-temporal lesions) might result in profound source confusions, called confabulations. Neuroimaging techniques provide new evidence regarding more specific links between underlying brain mechanisms and the normal cognitive processes involved in evaluating memories. One hypothesis is that the right prefrontal cortex (PFC) subserves heuristic judgments based on easily assessed qualities (such as familiarity or perceptual detail) and the left PFC (or the right and left PFC together) subserves more systematic judgments requiring more careful analysis of memorial qualities or retrieval and evaluation of additional supporting or disconfirming information. Such heuristic and systematic processes can be disrupted not only by brain damage but also, for example, by hypnosis, social demands and motivational factors, suggesting caution in the methods used by `memory exploring' professions (therapists, police officers, lawyers, etc.) in order to avoid inducing false memories.

  6. Disfluent presentations lead to the creation of more false memories.

    Science.gov (United States)

    Sanchez, Christopher A; Naylor, Jamie S

    2018-01-01

    The creation of false memories within the Deese-Roediger-McDermott (DRM) paradigm has been shown to be sensitive to many factors such as task instructions, participant mood, or even presentation modality. However, do other simple perceptual differences also impact performance on the DRM and the creation of false memories? This study explores the potential impact of changes in perceptual disfluency on DRM performance. To test for a potential influence of disfluency on false memory creation, participants viewed lists under either perceptually disfluent conditions or not. Results indicated that disfluency did significantly impact performance in the DRM paradigm; more disfluent presentations significantly increased the recall and recognition of unpresented information, although they did not impact recall or recognition of presented information. Thus, although disfluency did impact performance, disfluency did not produce a positive benefit related to overall task performance. This finding instead suggests that more disfluent presentations can increase the likelihood that false memories are created, and provide little positive performance benefit.

  7. False color viewing device

    International Nuclear Information System (INIS)

    Kronberg, J.W.

    1992-01-01

    A viewing device for observing objects in near-infrared false-color comprising a pair of goggles with one or more filters in the apertures, and pads that engage the face for blocking stray light from the sides so that all light reaching the user's eyes come through the filters. The filters attenuate most visible light and pass near-infrared (having wavelengths longer than approximately 700 nm) and a small amount of blue-green and blue-violet (having wavelengths in the 500 to 520 nm and shorter than 435 nm, respectively). The goggles are useful for looking at vegetation to identify different species and for determining the health of the vegetation, and to detect some forms of camouflage. 7 figs

  8. False positive reaction due to endogenous biotin activity in glandular epithelium of decidua Reação falso positiva em epitélio glandular da decídua devido a atividade endógena de biotina

    Directory of Open Access Journals (Sweden)

    Liliana Cruz Spano

    2005-06-01

    Full Text Available Biotin-labeled probe was used in an in situ hybridisation assay to localize virus infection in formalin-fixed, paraffin embedded tissues taken from eleven abortion cases. Probes for human cytomegalovirus (HCMV, human Parvovirus B19 (B19 and human adenovirus type 2 (HAd2, were labeled with biotin-11-dUTP by nick-translation reaction. Streptavidin-alkaline-phosphatase (SAP was used to detect biotin, followed by 4-nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP solution. Positive reaction was observed in nucleus of glandular ephitelium cells of decidua either in positive or in negative control at first and second gestational trimester. The reaction was not inhibited with blocking solution for alkaline phosphatase endogenous activity and it persisted even with probes omission. The use of adequate negative control permitted to reveal the presence of nuclear biotin in glandular epithelium of decidua, responsible for false positivity in detection systems involving streptavidin biotin system (StrepABC. The stained cells resembled to cytophatic effect due to herpesvirus, which could induce further misinterpretation. The results obtained in this study strongly recommend that DNA detection by in situ hybridisation reaction in gestational endometrium should be done without using StrepABC system.Sondas marcadas com biotina foram utilizadas neste trabalho para detecção de infecção viral por hibridização in situ em tecidos fixados com formalina e embebidos em parafina de 11 casos obtidos de abortamento. Sondas para citomegalovírus humano (HCMV, parvovírus B19 humano (B19 e adenovírus humano tipo 2 (HAd2, foram marcadas com biotina-11-dUTP através da reação de nick-translation. Estreptavidina conjugada com fosfatase alcalina (SAP seguida por solução de 4-nitro-azul de tetrazolio/5-bromo-4-cloro-3-indolil fosfato (NBT/BCIP foram utilizadas para detecção da biotina após a reação de hibridização. Reação positiva foi

  9. Too Good to be False: Nonsignificant Results Revisited

    Directory of Open Access Journals (Sweden)

    Chris H. J. Hartgerink

    2017-03-01

    Full Text Available Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant findings may just be ‘too good to be false’. We examined evidence for false negatives in nonsignificant results in three different ways. We adapted the Fisher test to detect the presence of at least one false negative in a set of statistically nonsignificant results. Simulations show that the adapted Fisher method generally is a powerful method to detect false negatives. We examined evidence for false negatives in the psychology literature in three applications of the adapted Fisher method. These applications indicate that (i the observed effect size distribution of nonsignificant effects exceeds the expected distribution assuming a null-effect, and approximately two out of three (66.7% psychology articles reporting nonsignificant results contain evidence for at least one false negative, (ii nonsignificant results on gender effects contain evidence of true nonzero effects, and (iii the statistically nonsignificant replications from the Reproducibility Project Psychology (RPP do not warrant strong conclusions about the absence or presence of true zero effects underlying these nonsignificant results. We conclude that false negatives deserve more attention in the current debate on statistical practices in psychology. Potentially neglecting effects due to a lack of statistical power can lead to a waste of research resources and stifle the scientific discovery process.

  10. The APS x-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of third generation synchrotron radiation sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS x-ray undulators will increase the brilliance in the 3-40 KeV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve sub-micron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper

  11. The APS X-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of thirs generation synchrotron sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS X-ray undulators will increase the brilliance in the 3-40 keV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve submicron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper. (orig.)

  12. Serum albumin and globulin analysis for hepatocellular carcinoma detection avoiding false-negative results from alpha-fetoprotein test negative subjects

    Science.gov (United States)

    Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong

    2013-11-01

    Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.

  13. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Science.gov (United States)

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  14. Tests of crossed-wire position sensitive photomultipliers for scintillating fiber particle tracking

    International Nuclear Information System (INIS)

    Perdrisat, C.F.; Koechner, D.; Majewski, S.; Pourang, R.; Wilson, C.D.; Zorn, C.

    1995-01-01

    Several applications of two Hamamatsu position sensitive photomultiplier tubes to the detection of high energy particles with scintillating fibers are discussed. The PMTs are of the multiwire anode grid design, type R2486 and R4135. These tubes were tested with both single samples and arrays of 2 and 3 mm diameter scintillating fibers. Measurements of position resolution of the PMTs using either the charge digitization or the delay line readout techniques were made. The results indicate an intrinsic inability of the technique to reconstruct the actual position of a fiber on the photocathode when its location falls halfway between two grid wires. A way to overcome this limit is suggested. (orig.)

  15. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  16. The prevalence of skin-test-positive allergic rhinitis in Danish adults

    DEFF Research Database (Denmark)

    Linneberg, A; Jørgensen, T; Nielsen, N H

    2000-01-01

    BACKGROUND: It is disputed whether increases in self-reported respiratory allergy represent a true increase or merely increased recognition. We aimed to investigate whether the prevalence of skin-prick-test (SPT)-positive allergic rhinitis had increased in an adult general population in Copenhagen...... (participation rate 74.6%) and 482 (participation rate 53.4%) subjects were examined in 1990 and 1998, respectively. Diagnoses of SPT-positive allergic rhinitis were based on a history of nasal symptoms on exposure to allergens and SPT positivity to allergens. RESULTS: The prevalence of a diagnosis of SPT...

  17. Test measurement of a new TESLA cavity beam position monitor at the ELBE linac

    International Nuclear Information System (INIS)

    Sargsyan, V.; Schreiber, H.J.; Evtushenko, P.; Schurig, R.

    2004-01-01

    A new type of a cavity BPM proposed for beam position determination along the TESLA linac was tested at the accelerator ELBE in Rossendorf / Dresden. Measurements using an improved BPM (large and stable cross-talk isolation, significantly less energy dissipation, a novel LO signal generation) were performed in single- and multi-bunch regimes. Agreement with expectations was found. The low bunch charge available allowed for preliminary measurements on sensitivity and position resolution, which extrapolated to TESLA would ful l the demands for precise bunch-to-bunch position determination. Possible improvements, in particular on the signal processing scheme, are also discussed. (orig.)

  18. A very low geno2pheno false positive rate is associated with poor viro-immunological response in drug-naïve patients starting a first-line HAART.

    Science.gov (United States)

    Armenia, Daniele; Soulie, Cathia; Di Carlo, Domenico; Fabeni, Lavinia; Gori, Caterina; Forbici, Federica; Svicher, Valentina; Bertoli, Ada; Sarmati, Loredana; Giuliani, Massimo; Latini, Alessandra; Boumis, Evangelo; Zaccarelli, Mauro; Bellagamba, Rita; Andreoni, Massimo; Marcelin, Anne-Geneviève; Calvez, Vincent; Antinori, Andrea; Ceccherini-Silberstein, Francesca; Perno, Carlo-Federico; Santoro, Maria Mercedes

    2014-01-01

    We previously found that a very low geno2pheno false positive rate (FPR ≤ 2%) defines a viral population associated with low CD4 cell count and the highest amount of X4-quasispecies. In this study, we aimed at evaluating whether FPR ≤ 2% might impact on the viro-immunological response in HIV-1 infected patients starting a first-line HAART. The analysis was performed on 305 HIV-1 B subtype infected drug-naïve patients who started their first-line HAART. Baseline FPR (%) values were stratified according to the following ranges: ≤ 2; 2-5; 5-10; 10-20; 20-60; >60. The impact of genotypically-inferred tropism on the time to achieve immunological reconstitution (a CD4 cell count gain from HAART initiation ≥ 150 cells/mm(3)) and on the time to achieve virological success (the first HIV-RNA measurement immunological reconstitution was overall 75.5%, and it was significantly lower for FPR ≤ 2 (54.1%) in comparison to other FPR ranks (78.8%, FPR 2-5; 77.5%, FPR 5-10; 71.7%, FPR 10-20; 81.8%, FPR 20-60; 75.1%, FPR >60; p = 0.008). The overall proportion of patients achieving virological success was 95.5% by 12 months of therapy. Multivariable Cox analyses showed that patients having pre-HAART FPR ≤ 2% had a significant lower relative adjusted hazard [95% C.I.] both to achieve immunological reconstitution (0.37 [0.20-0.71], p = 0.003) and to achieve virological success (0.50 [0.26-0.94], p = 0.031) than those with pre-HAART FPR >60%. Beyond the genotypically-inferred tropism determination, FPR ≤ 2% predicts both a poor immunological reconstitution and a lower virological response in drug-naïve patients who started their first-line therapy. This parameter could be useful to identify patients potentially with less chance of achieving adequate immunological reconstitution and virological undetectability.

  19. Genetic Testing and Post-Testing Decision Making among BRCA-Positive Mutation Women: A Psychosocial Approach.

    Science.gov (United States)

    Hesse-Biber, Sharlene; An, Chen

    2016-10-01

    Through an analysis of an online survey of women who tested positive for the BRCA genetic mutation for breast cancer, this research uses a social constructionist and feminist standpoint lens to understand the decision-making process that leads BRCA-positive women to choose genetic testing. Additionally, this research examines how they socially construct and understand their risk for developing breast cancer, as well as which treatment options they undergo post-testing. BRCA-positive women re-frame their statistical medical risk for developing cancer and their post-testing treatment choices through a broad psychosocial context of engagement that also includes their social networks. Important psychosocial factors drive women's medical decisions, such as individual feelings of guilt and vulnerability, and the degree of perceived social support. Women who felt guilty and fearful that they might pass the BRCA gene to their children were more likely to undergo risk reducing surgery. Women with at least one daughter and women without children were more inclined toward the risk reducing surgery compared to those with only sons. These psychosocial factors and social network engagements serve as a "nexus of decision making" that does not, for the most part, mirror the medical assessments of statistical odds for hereditary cancer development, nor the specific treatment protocols outlined by the medical establishment.

  20. Positive hepatitis B surface antigen tests due to recent vaccination: a persistent problem

    Directory of Open Access Journals (Sweden)

    Rysgaard Carolyn D

    2012-09-01

    Full Text Available Abstract Background Hepatitis B virus (HBV is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone results. Results During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days

  1. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sojeong, E-mail: sojung8681@postech.ac.kr; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-11

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  2. [The exploration on optimization of two alternatives between roll test and Dix-Hallpike test in benign paroxysmal positional vertigo].

    Science.gov (United States)

    Ji, R; Chen, T S; Wang, W; Xu, K X; Li, S S; Wen, C; Liu, Q; Lin, P

    2017-06-07

    Objective: To analyze the objective characteristics of roll test and Dix-Hallpike test in benign paroxysmal positional vertigo(BPPV)patients, discussing the premier solution of positional test. Methods: A total of 230 patients with BPPV, whereas 170 posterior semicircular canal canalithiasis (PSC-Can) BPPV and 60 horizontal semicircular canal canalithiasis (HSC-Can) BPPV were involved respectively. The induced nystagmus in roll test and Dix-Hallpike test was recorded by video nystagmuo graph (VNG), and the direction, intensity and time characteristics of nystagmus were compared in various BPPV.SPSS19.0 software was used for statistical analysis. Results: Vertically upward nystagmus was induced by hanging in 170 PSC-Can Dix-Hallpike test, and the nystagmus reversed and turned weaker when the subjects came to sit. The intensity of nystagmus at turning to lesion side by hanging and sitting were (30.3±14.1)°/s and (12.6±7.5)°/s respectively, the difference was statistically significant ( t =20.153, P <0.05). However, no nystagmus was induced in PSC-Can roll test. Horizontal nystagmus in the same direction with turning was induced in 60 HSC-Can roll test. The intensity of nystagmus at turning to lesion side and normal side was (42.0±18.0)°/s and (20.3±8.7)°/s respectively, the difference was statistically significant ( t =12.731, P <0.05). Furthermore, horizontal nystagmus in the same direction with turning was induced in 57 HSC-Can Dix-Hallpike. The coherence was 95% with the results of roll test. Conclusions: Dix-Hallpike test can not only be used to diagnose PSC-Can, but also induce nystagmus in HSC-Can effectively. Whereas the roll test only show significance in diagnosing HSC-Can. To avoid uncomfortable stimulation to patients as much as possible, we suggest to use Dix-Hallpike test at first, and to judge whether using roll test based on the result of the horizontal nystagmus.

  3. Retention of children under 18 months testing HIV positive in care in ...

    African Journals Online (AJOL)

    Retention of children under 18 months testing HIV positive in care in Swaziland: a retrospective study. ... children within the first two months of life and linking them into care. However, as time progresses the retention of children in care declines. Innovative strategies need to be developed to enhance patient retention.

  4. Hydroxychloroquine-induced acute generalized exanthematous pustulosis with positive patch-testing.

    Science.gov (United States)

    Charfi, Ons; Kastalli, Sarrah; Sahnoun, Rym; Lakhoua, Ghozlane

    2015-01-01

    Acute generalized exanthematous pustulosis (AGEP) is a severe cutaneous adverse reaction, mostly induced by drugs. Hydroxychloroquine have been rarely reported in literature as a causative drug of this reaction. We report a case of AGEP induced by hydroxychloroquine with systemic involvement and confirmed by positive patch testing.

  5. Test-retest reliability of joint position and kinesthetic sense in the elbow of healthy subjects

    DEFF Research Database (Denmark)

    Juul-Kristensen, B.; Lund, Hans Aage; Hansen, K.

    2008-01-01

    Proprioception is an important effect measure in neuromuscular function training in physiotherapy. Reliability studies of methods for measuring proprioception are few on joint position sense (JPS) and threshold to detection of a passive movement (TDPM) on the elbow. The aim was to study test-rete...

  6. Control rod position and temperature coefficients in HTTR power-rise tests. Interim report

    International Nuclear Information System (INIS)

    Fujimoto, Nozomu; Nojiri, Naoki; Takada, Eiji; Saito, Kenji; Kobayashi, Shoichi; Sawahata, Hiroaki; Kokusen, Sigeru

    2001-03-01

    Power-rise tests of the High Temperature Engineering Test Reactor (HTTR) have been carried out aiming to achieve 100% power. So far, 50% of power operation and many tests have been carried out. In the HTTR, temperature change in core is so large to achieve the outlet coolant temperature of 950degC. To improve the calculation accuracy of the HTTR reactor physics characteristics, control rod positions at criticality and temperature coefficients were measured at each step to achieve 50% power level. The calculations were carried out using Monte Carlo code and diffusion theory with temperature distributions in the core obtained by reciprocal calculation of thermo-hydraulic code and diffusion theory. Control rod positions and temperature coefficients were calculated by diffusion theory and Monte Carlo method. The test results were compared to calculation results. The control rod positions at criticality showed good agreement with calculation results by Monte Carlo method with error of 50 mm. The control position at criticality at 100% was predicted around 2900mm. Temperature coefficients showed good agreement with calculation results by diffusion theory. The improvement of calculation will be carried out comparing the measured results up to 100% power level. (author)

  7. Outcome in clients with positive pregnancy test following IVF/ICSI ...

    African Journals Online (AJOL)

    Background: A retrospective analysis of the outcome of all patients who have recorded a positive pregnancy test following IVF/ICSI treatment from June 1999 to December 2002 was done. Materials and Methods: A total of 1256 treatment cycles were carried out using the long day 1 (early follicular phase) or day 21 ...

  8. Testing Theoretical Relationships: Factors Influencing Positive Health Practices (PHP) in Filipino College Students

    Science.gov (United States)

    Ayres, Cynthia; Mahat, Ganga; Atkins, Robert

    2013-01-01

    Objective: To examine variables influencing the positive health practices (PHP) of Filipino college students to gain a better understanding of health practices in this ethnic/racial group. Cross-sectional study tested theoretical relationships postulated among (a) PHP, (b) social support (SS), (c) optimism, and (d) acculturation. Participants: A…

  9. [Mes differ by positioning: empirical testing of decentralized dynamics of the self].

    Science.gov (United States)

    Mizokami, Shinichi

    2013-10-01

    The present study empirically tested the conceptualization of the decentralized dynamics of the self proposed by Hermans & Kempen (1993), which they developed theoretically and from clinical cases, not from large samples of empirical data. They posited that worldviews and images of the self could vary by positioning even in the same individual, and denied that the ego was an omniscient entity that knew and controlled all aspects of the self (centralized ego). Study 1 tested their conceptualization empirically with 47 university students in an experimental group and 17 as a control group. The results showed that the scores on the Rosenberg's self-esteem scale and images of the Mes in the experimental group significantly varied by positioning, but those in the control group did not. Similar results were found in Study 2 with a sample of 120 university students. These results empirically supported the conceptualization of the decentralized dynamics of the self.

  10. Sensitivity, Specificity, and Positivity Predictors of the Pneumococcal Urinary Antigen Test in Community-Acquired Pneumonia.

    Science.gov (United States)

    Molinos, Luis; Zalacain, Rafael; Menéndez, Rosario; Reyes, Soledad; Capelastegui, Alberto; Cillóniz, Catia; Rajas, Olga; Borderías, Luis; Martín-Villasclaras, Juan J; Bello, Salvador; Alfageme, Inmaculada; Rodríguez de Castro, Felipe; Rello, Jordi; Ruiz-Manzano, Juan; Gabarrús, Albert; Musher, Daniel M; Torres, Antoni

    2015-10-01

    Detection of the C-polysaccharide of Streptococcus pneumoniae in urine by an immune-chromatographic test is increasingly used to evaluate patients with community-acquired pneumonia. We assessed the sensitivity and specificity of this test in the largest series of cases to date and used logistic regression models to determine predictors of positivity in patients hospitalized with community-acquired pneumonia. We performed a multicenter, prospective, observational study of 4,374 patients hospitalized with community-acquired pneumonia. The urinary antigen test was done in 3,874 cases. Pneumococcal infection was diagnosed in 916 cases (21%); 653 (71%) of these cases were diagnosed exclusively by the urinary antigen test. Sensitivity and specificity were 60 and 99.7%, respectively. Predictors of urinary antigen positivity were female sex; heart rate≥125 bpm, systolic blood pressureantibiotic treatment; pleuritic chest pain; chills; pleural effusion; and blood urea nitrogen≥30 mg/dl. With at least six of all these predictors present, the probability of positivity was 52%. With only one factor present, the probability was only 12%. The urinary antigen test is a method with good sensitivity and excellent specificity in diagnosing pneumococcal pneumonia, and its use greatly increased the recognition of community-acquired pneumonia due to S. pneumoniae. With a specificity of 99.7%, this test could be used to direct simplified antibiotic therapy, thereby avoiding excess costs and risk for bacterial resistance that result from broad-spectrum antibiotics. We also identified predictors of positivity that could increase suspicion for pneumococcal infection or avoid the unnecessary use of this test.

  11. 9 CFR 80.4 - Segregation of animals positive to an official Johne's disease test during interstate movement.

    Science.gov (United States)

    2010-01-01

    ... official Johne's disease test during interstate movement. 80.4 Section 80.4 Animals and Animal Products... animals positive to an official Johne's disease test during interstate movement. Animals that are positive... from the animals positive to an official Johne's disease test to the healthy animals in the vehicle. ...

  12. 9 CFR 80.3 - Movement of domestic animals that are positive to an official Johne's disease test.

    Science.gov (United States)

    2010-01-01

    ... positive to an official Johne's disease test. 80.3 Section 80.3 Animals and Animal Products ANIMAL AND... animals that are positive to an official Johne's disease test. (a) Movement of domestic animals for slaughter. Domestic animals that are positive to an official Johne's disease test may be moved interstate...

  13. Nuclear war as false memory

    Directory of Open Access Journals (Sweden)

    John Timberlake

    2014-10-01

    Full Text Available In this paper Timberlake outlines aspects of his creative practice as an artist, explaining his fascination for the ‘fictions of nuclear war’ – a war that never happened and so became the subject of ‘false memory’. Highlighting discontinued historical trajectories, the author shows how the cultural legacy of Britain’s nuclear test programme of the 1950s and ’60s may be explored meaningfully in paintings and photography resulting from his archival research at the Imperial War Museum in London.

  14. Simulation of Model Force-Loading with Changing Its Position in the Wind Tunnel Test Section

    Directory of Open Access Journals (Sweden)

    V. T. Bui

    2015-01-01

    Full Text Available When planning and implementing an aerodynamic experiment, model sizes and its position in the test section of the wind tunnel (WT play very important role. The paper focuses on the value variations of the aerodynamic characteristics of a model through changing its position in the WT test section and on the attenuation of the velocity field disturbance in front of the model. Flow around aerodynamic model profile in the open test section of the low-speed WT T-500 is simulated at BMSTU Department SM3. The problem is solved in a two-dimensional case using the ANSYS Fluent package. The mathematical model of flow is based on the Reynolds equations closed by the SST turbulence model. The paper also presents the results of the experiment. Experiments conducted in WT T-500 well correlate with the calculated data and show the optimal position in the middle of the test section when conducting the weighing and drainage experiments. Disturbance of tunnel dynamic pressure (velocity head and flow upwash around the model profile and circular cylinder in the WT test section is analyzed. It was found that flow upstream from the front stagnation point on the body weakly depends on the Reynolds number and obtained results can be used to assess the level of disturbances in the flow around a model by incompressible airflow.

  15. Positive cell-free fetal DNA testing for trisomy 13 reveals confined placental mosaicism.

    Science.gov (United States)

    Hall, April L; Drendel, Holli M; Verbrugge, Jennifer L; Reese, Angela M; Schumacher, Katherine L; Griffith, Christopher B; Weaver, David D; Abernathy, Mary P; Litton, Christian G; Vance, Gail H

    2013-09-01

    We report on a case in which cell-free fetal DNA was positive for trisomy 13 most likely due to confined placental mosaicism. Cell-free fetal DNA testing analyzes DNA derived from placental trophoblast cells and can lead to incorrect results that are not representative of the fetus. We sought to confirm commercial cell-free fetal DNA testing results by chorionic villus sampling and amniocentesis. These results were followed up by postnatal chromosome analysis of cord blood and placental tissue. First-trimester cell-free fetal DNA test results were positive for trisomy 13. Cytogenetic analysis of chorionic villus sampling yielded a mosaic karyotype of 47,XY,+13[10]/46,XY[12]. G-banded analysis of amniotic fluid was normal, 46,XY. Postnatal cytogenetic analysis of cord blood was normal. Karyotyping of tissues from four quadrants of the placenta demonstrated mosaicism for trisomy 13 in two of the quadrants and a normal karyotype in the other two. Our case illustrates several important aspects of this new testing methodology: that cell-free fetal DNA may not be representative of the fetal karyotype; that follow-up with diagnostic testing of chorionic villus sampling and/or amniotic fluid for abnormal test results should be performed; and that pretest counseling regarding the full benefits, limitations, and possible testing outcomes of cell-free fetal DNA screening is important.

  16. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    Science.gov (United States)

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  17. [An attempt to construct a Japanese version of the Implicit Positive and Negative Affect Test (IPANAT)].

    Science.gov (United States)

    Shimoda, Shunsuke; Okubo, Nobutoshi; Kobayashi, Mai; Sato, Shigetaka; Kitamura, Hideya

    2014-08-01

    The Implicit Positive and Negative Affect Test (IPANAT) is an instrument for the indirect assessment of positive and negative affect. A Japanese version of the IPANAT was developed and its reliability and validity were examined. In Study 1, factor analysis identified two independent factors that could be interpreted as implicit positive and negative affect, which corresponded to the original version. The Japanese IPANAT also had sufficient internal consistency and acceptable test-retest reliability. In Study 2, we demonstrated that the Japanese IPANAT was associated with explicit state affect (e.g., PANAS), extraversion, and neuroticism, which indicated its adequate construct validity. In Study 3, we examined the extent to which the Japanese IPANAT was sensitive to changes in affect by assessing a set of IPANAT items after the presentation of positive, negative, or neutral photographs. The results indicated that the Japanese IPANAT was sufficiently sensitive to changes in affect resulting from affective stimuli. Taken together, these studies suggest that the Japanese version of the IPANAT is a useful instrument for the indirect assessment of positive and negative affect.

  18. Design, Development and Testing of a Semicircular Type Capacitive Angular Position Sensor

    Directory of Open Access Journals (Sweden)

    Nikhil GAURAV

    2011-06-01

    Full Text Available A low cost semicircular type capacitive angular position sensor has been designed, developed and tested. It is made of two semicircular parallel plates where one plate is fixed and another plate is connected with the rotor whose angular position is to be measured. When the angular position of the rotor changes with respect to the fixed plate, the overlapping area between the two plates of the capacitor is varied causing a change in capacitance value. Capacitance variation obtained due to the change in angular position is in the nano farad range. For signal conditioning, series R-L-C resonating circuit instead of conventional bridge circuit has been used to convert the sensor capacitance variation in to voltage. Experimental result shows that the capacitance for change in angular position 0º-180º increases linearly and for 180º-360º it decreases linearly. To get a linearly increasing response of same slope for the full scale of 0º-360º, a suitable linearising circuit has been designed, developed and tested. Sensor output along with the signal conditioning shows good linearity and repeatability.

  19. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    Science.gov (United States)

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  20. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures

    Directory of Open Access Journals (Sweden)

    Hong-wei Pan

    2018-03-01

    Full Text Available Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  1. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Testing HIV positive in pregnancy: A phenomenological study of women's experiences.

    Science.gov (United States)

    Lingen-Stallard, Andrew; Furber, Christine; Lavender, Tina

    2016-04-01

    globally women receive HIV testing in pregnancy; however, limited information is available on their experiences of this potentially life-changing event. This study aims to explore women's experiences of receiving a positive HIV test result following antenatal screening. a qualitative, phenomenological approach. two public National Health Service (NHS) hospitals and HIV support organisations. a purposive sampling strategy was used. Thirteen black African women with a positive HIV result, in England, participated. data were collected using in-depth semi-structured interviews. An interpretive phenomenological approach to data analysis was used. the emergent phenomenon was transition and transformation of 'being,' as women accepted HIV as part of their lives. Paired themes support the phenomenon: shock and disbelief; anger and turmoil; stigma and confidentiality issues; acceptance and resilience. Women had extreme reactions to their positive HIV diagnosis, compounded by the cultural belief that they would die. Initial disbelief of the unexpected result developed into sadness at the loss of their old self. Turmoil was evident, as women considered termination of pregnancy, self-harm and suicide. Women felt isolated from others and relationship breakdowns often occurred. Most reported the pervasiveness of stigma, and how this was managed alongside living with HIV. Coping strategies included keeping HIV 'secret' and making their child(ren) the prime focus of life. Growing resilience was apparent with time. this study gives midwives unique understanding of the complexities and major implications for women who tested positive for HIV. Women's experiences resonated with processes of bereavement, providing useful insight into a transitional and transformational period, during which appropriate support can be targeted. midwives are crucial in improving the experience of women when they test HIV positive and to do this they need to be appropriately trained. Midwives need to

  3. Clinical experience of laboratory follow-up with noninvasive prenatal testing using cell-free DNA and positive microdeletion results in 349 cases.

    Science.gov (United States)

    Schwartz, S; Kohan, M; Pasion, R; Papenhausen, P R; Platt, L D

    2018-02-01

    Screening via noninvasive prenatal testing (NIPT) involving the analysis of cell-free DNA (cfDNA) from plasma has become readily available to screen for chromosomal and DNA aberrations through maternal blood. This report reviews a laboratory's experience with follow-up of positive NIPT screens for microdeletions. Patients that were screened positive by NIPT for a microdeletion involving 1p, 4p, 5p, 15q, or 22q who underwent diagnostic studies by either chorionic villus sampling or amniocentesis were evaluated. The overall positive predictive value for 349 patients was 9.2%. When a microdeletion was confirmed, 39.3% of the cases had additional abnormal microarray findings. Unrelated abnormal microarray findings were detected in 11.8% of the patients in whom the screen positive microdeletion was not confirmed. Stretches of homozygosity in the microdeletion were frequently associated with a false positive cfDNA microdeletion result. Overall, this report reveals that while cfDNA analysis will screen for microdeletions, the positive predictive value is low; in our series it is 9.2%. Therefore, the patient should be counseled accordingly. Confirmatory diagnostic microarray studies are imperative because of the high percentage of false positives and the frequent additional abnormalities not delineated by cfDNA analysis. © 2018 John Wiley & Sons, Ltd.

  4. Physiologic performance test differences in female volleyball athletes by competition level and player position.

    Science.gov (United States)

    Schaal, Monique; Ransdell, Lynda B; Simonson, Shawn R; Gao, Yong

    2013-07-01

    The purpose of this study was to examine physiologic performance test differences by competition level (high school and Division-I collegiate athletes) and player position (hitter, setter, defensive specialist) in 4 volleyball-related tests. A secondary purpose was to establish whether a 150-yd shuttle could be used as a field test to assess anaerobic capacity. Female participants from 4 varsity high school volleyball teams (n = 27) and 2 Division-I collegiate volleyball teams (n = 26) were recruited for the study. Participants completed 4 performance-based field tests (vertical jump, agility T-test, and 150- and 300-yd shuttle runs) after completing a standardized dynamic warm-up. A 2-way multivariate analysis of variance with Bonferroni post hoc adjustments (when appropriate) and effect sizes were used for the analyses. The most important findings of this study were that (a) college volleyball athletes were older, heavier, and taller than high school athletes; (b) high school athletes had performance deficiencies in vertical jump/lower-body power, agility, and anaerobic fitness; (c) lower-body power was the only statistically significant difference in the performance test measures by player position; and (d) the correlation between the 150- and 300-yd shuttle was moderate (r = 0.488). Female high school volleyball players may enhance their ability to play collegiate volleyball by improving their vertical jump, lower-body power, agility, and anaerobic fitness. Furthermore, all player positions should emphasize lower-body power conditioning. These physical test scores provide baseline performance scores that should help strength and conditioning coaches create programs that will address deficits in female volleyball player performance, especially as they transition from high school to college.

  5. Tilt angles and positive response of head-up tilt test in children with orthostatic intolerance.

    Science.gov (United States)

    Lin, Jing; Wang, Yuli; Ochs, Todd; Tang, Chaoshu; Du, Junbao; Jin, Hongfang

    2015-01-01

    This study aimed at examining three tilt angle-based positive responses and the time to positive response in a head-up tilt test for children with orthostatic intolerance, and the psychological fear experienced at the three angles during head-up tilt test. A total of 174 children, including 76 boys and 98 girls, aged from 4 to 18 years old (mean 11.3±2.8 years old), with unexplained syncope, were randomly divided into three groups, to undergo head-up tilt test at the angles of 60°, 70° and 80°, respectively. The diagnostic rates and times were analysed, and Wong-Baker face pain rating scale was used to access the children's psychological fear. There were no significant differences in diagnostic rates of postural orthostatic tachycardia syndrome and vasovagal syncope at different tilt angles during the head-up tilt test (p>0.05). There was a significant difference, however, in the psychological fear at different tilt angles utilising the Kruskal-Wallis test (χ2=36.398, ptest (ptest for vasovagal syncope or for postural orthostatic tachycardia syndrome. Hence, it is suggested that a tilt angle of 60° and head-up tilt test time of 45 minutes should be suitable for children with vasovagal syncope.

  6. Risks of Using Bedside Tests to Verify Nasogastric Tube Position in Adult Patients

    Directory of Open Access Journals (Sweden)

    Melody Ni

    2014-12-01

    Full Text Available Nasogastric (NG tubes are commonly used for enteral feeding. Complications of feeding tube misplacement include malnutrition, pulmonary aspiration, and even death. We built a Bayesian network (BN to analyse the risks associated with available bedside tests to verify tube position. Evidence on test validity (sensitivity and specificity was retrieved from a systematic review. Likelihood ratios were used to select the best tests for detecting tubes misplaced in the lung or oesophagus. Five bedside tests were analysed including magnetic guidance, aspirate pH, auscultation, aspirate appearance, and capnography/colourimetry. Among these, auscultation and appearance are non-diagnostic towards lung or oesophagus placements. Capnography/ colourimetry can confirm but cannot rule out lung placement. Magnetic guidance can rule out both lung and oesophageal placement. However, as a relatively new technology, further validation studies are needed. The pH test with a cut-off at 5.5 or lower can rule out lung intubation. Lowering the cut-off to 4 not only minimises oesophageal intubation but also provides extra safety as the sensitivity of pH measurement is reduced by feeding, antacid medication, or the use of less accurate pH paper. BN is an effective tool for representing and analysing multi-layered uncertainties in test validity and reliability for the verification of NG tube position. Aspirate pH with a cut-off of 4 is the safest bedside method to minimise lung and oesophageal misplacement.

  7. Acceptance of referral for partners by clients testing positive for human immunodeficiency virus

    Directory of Open Access Journals (Sweden)

    Netsanet F

    2013-01-01

    Full Text Available Fetene Netsanet,1 Ayalew Dessie21IMA World Health SuddHealth Multi Donor Trust Fund-Basic Package of Health Services Project, Juba, South Sudan; 2United States Agency for International Development, Private Health Sector Program, Abt Associates Inc, Addis Ababa, EthiopiaBackground: Human immunodeficiency virus (HIV-positive individuals who do not disclose their HIV status to their partners are more likely to present late for HIV and acquired immune deficiency syndrome (AIDS care than those who have disclosed their HIV status to their partners. A major area of challenge with regards to HIV counseling for clients is disclosure of their HIV status to their partners. The main methods of partner notification are patient referral, provider referral, contract referral, and outreach assistance. The emphasis on a plausible and comprehensive partner referral strategy for widespread positive case detection in resource-limited countries needs to be thought out and developed.Methods: A qualitative study was conducted among newly HIV-positive clients to identify partners for notification and acceptance of referral by their partners. Health service providers working in HIV testing and counseling clinics were also provided with semistructured questionnaires in order to assess their view towards partner notification strategies for clients testing positive for HIV.Results: Fifteen newly diagnosed HIV-positive clients were counseled to provide referral slips to their partners. All clients agreed and took the referral card. However, only eight were willing and actually provided the card to their partners. Five of the eight partners of clients who tested HIV-positive and who were provided with referral cards responded to the referral and were tested for HIV. Three were positive and two were negative. Nine of 11 counselors did not agree to requesting partner locator information from HIV-positive clients for contractual referral and/or outreach assistance. The findings

  8. Longitudinal investigation on learned helplessness tested under negative and positive reinforcement involving stimulus control.

    Science.gov (United States)

    Oliveira, Emileane C; Hunziker, Maria Helena

    2014-07-01

    In this study, we investigated whether (a) animals demonstrating the learned helplessness effect during an escape contingency also show learning deficits under positive reinforcement contingencies involving stimulus control and (b) the exposure to positive reinforcement contingencies eliminates the learned helplessness effect under an escape contingency. Rats were initially exposed to controllable (C), uncontrollable (U) or no (N) shocks. After 24h, they were exposed to 60 escapable shocks delivered in a shuttlebox. In the following phase, we selected from each group the four subjects that presented the most typical group pattern: no escape learning (learned helplessness effect) in Group U and escape learning in Groups C and N. All subjects were then exposed to two phases, the (1) positive reinforcement for lever pressing under a multiple FR/Extinction schedule and (2) a re-test under negative reinforcement (escape). A fourth group (n=4) was exposed only to the positive reinforcement sessions. All subjects showed discrimination learning under multiple schedule. In the escape re-test, the learned helplessness effect was maintained for three of the animals in Group U. These results suggest that the learned helplessness effect did not extend to discriminative behavior that is positively reinforced and that the learned helplessness effect did not revert for most subjects after exposure to positive reinforcement. We discuss some theoretical implications as related to learned helplessness as an effect restricted to aversive contingencies and to the absence of reversion after positive reinforcement. This article is part of a Special Issue entitled: insert SI title. Copyright © 2014. Published by Elsevier B.V.

  9. How does negative emotion cause false memories?

    Science.gov (United States)

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  10. High confidence in falsely recognizing prototypical faces.

    Science.gov (United States)

    Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen

    2018-06-01

    We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.

  11. Development of a superconducting position sensor for the Satellite Test of the Equivalence Principle

    Science.gov (United States)

    Clavier, Odile Helene

    The Satellite Test of the Equivalence Principle (STEP) is a joint NASA/ESA mission that proposes to measure the differential acceleration of two cylindrical test masses orbiting the earth in a drag-free satellite to a precision of 10-18 g. Such an experiment would conceptually reproduce Galileo's tower of Pisa experiment with a much longer time of fall and greatly reduced disturbances. The superconducting test masses are constrained in all degrees of freedom except their axial direction (the sensitive axis) using superconducting bearings. The STEP accelerometer measures the differential position of the masses in their sensitive direction using superconducting inductive pickup coils coupled to an extremely sensitive magnetometer called a DC-SQUID (Superconducting Quantum Interference Device). Position sensor development involves the design, manufacture and calibration of pickup coils that will meet the acceleration sensitivity requirement. Acceleration sensitivity depends on both the displacement sensitivity and stiffness of the position sensor. The stiffness must kept small while maintaining stability of the accelerometer. Using a model for the inductance of the pickup coils versus displacement of the test masses, a computer simulation calculates the sensitivity and stiffness of the accelerometer in its axial direction. This simulation produced a design of pickup coils for the four STEP accelerometers. Manufacture of the pickup coils involves standard photolithography techniques modified for superconducting thin-films. A single-turn pickup coil was manufactured and produced a successful superconducting coil using thin-film Niobium. A low-temperature apparatus was developed with a precision position sensor to measure the displacement of a superconducting plate (acting as a mock test mass) facing the coil. The position sensor was designed to detect five degrees of freedom so that coupling could be taken into account when measuring the translation of the plate

  12. Characterization of human organ donors testing positive for type 1 diabetes-associated autoantibodies

    Science.gov (United States)

    Wiberg, A; Granstam, A; Ingvast, S; Härkönen, T; Knip, M; Korsgren, O; Skog, O

    2015-01-01

    In this study we aim to describe the characteristics of non-diabetic organ donors with circulating diabetes-associated autoantibodies collected within the Nordic Network for Islet Transplantation. One thousand and thirty organ donors have been screened in Uppsala for antibodies against glutamic acid decarboxylase (GADA) and islet antigen-2 (IA-2A). The 32 non-diabetic donors that tested positive for GADA (3·3% of all non-diabetic donors) were studied in more detail, together with 32 matched controls. Mean age among the autoantibody-positive donors was 52·6 (range 21–74), family history of type 1 diabetes (T1D) was unknown, and no donor was genetically predisposed for T1D regarding the human leucocyte antigen (HLA) locus. Subjects were analysed for islet cell antibodies (ICA), insulin autoantibodies (IAA) and zinc transporter 8 antibodies (ZnT8A), and pancreas morphology and clinical data were examined. Eight non-diabetic donors tested positive for two antibodies and one donor tested positive for four antibodies. No insulitis or other signs of a diabetic process were found in any of the donors. While inflammatory cells were present in all donors, subjects with high GADA titres had significantly higher CD45 cell numbers in exocrine tissue than controls. The extent of fibrosis was more pronounced in autoantibody-positive donors, even in subjects with lower GADA titres. Notably, it is possible that events not related directly to T1D (e.g. subclinical pancreatitis) may induce autoantibodies in some cases. PMID:26313035

  13. A comparative study of the typhidot (Dot-EIA) and Widal tests in blood culture positive cases of typhoid fever.

    Science.gov (United States)

    Khoharo, Haji Khan

    2011-07-01

    Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.

  14. Intellectual factors in false memories of patients with schizophrenia.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun

    2018-07-01

    The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. False recollection of emotional pictures in Alzheimer's disease.

    Science.gov (United States)

    Gallo, David A; Foster, Katherine T; Wong, Jessica T; Bennett, David A

    2010-10-01

    Alzheimer's Disease (AD) can reduce the effects of emotional content on memory for studied pictures, but less is known about false memory. In healthy adults, emotionally arousing pictures can be more susceptible to false memory effects than neutral pictures, potentially because emotional pictures share conceptual similarities that cause memory confusions. We investigated these effects in AD patients and healthy controls. Participants studied pictures and their verbal labels, and then picture recollection was tested using verbal labels as retrieval cues. Some of the test labels had been associated with a picture at study, whereas other had not. On this picture recollection test, we found that both AD patients and controls incorrectly endorsed some of the test labels that had not been studied with pictures. These errors were associated with medium to high levels of confidence, indicating some degree of false recollection. Critically, these false recollection judgments were greater for emotional compared to neutral items, especially for positively valenced items, in both AD patients and controls. Dysfunction of the amygdala and hippocampus in early AD may impair recollection, but AD did not disrupt the effect of emotion on false recollection judgments. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Unsaturated fatty acids show clear elicitation responses in a modified local lymph node assay with an elicitation phase, and test positive in the direct peptide reactivity assay.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Miyazaki, Hiroshi; Itagaki, Hiroshi

    2015-12-01

    The Organisation for Economic Co-operation and Development (OECD) Test Guidelines (TG) adopted the murine local lymph node assay (LLNA) and guinea pig maximization test (GPMT) as stand-alone skin sensitization test methods. However, unsaturated carbon-carbon double-bond and/or lipid acids afforded false-positive results more frequently in the LLNA compared to those in the GPMT and/or in human subjects. In the current study, oleic, linoleic, linolenic, undecylenic, fumaric, maleic, and succinic acid and squalene were tested in a modified LLNA with an elicitation phase (LLNA:DAE), and in a direct peptide reactivity assay (DPRA) to evaluate their skin-sensitizing potential. Oleic, linoleic, linolenic, undecylenic and maleic acid were positive in the LLNA:DAE, of which three, linoleic, linolenic, and maleic acid were positive in the DPRA. Furthermore, the results of the cross-sensitizing tests using four LLNA:DAE-positive chemicals were negative, indicating a chemical-specific elicitation response. In a previous report, the estimated concentration needed to produce a stimulation index of 3 (EC3) of linolenic acid, squalene, and maleic acid in the LLNA was LLNA. However, the skin-sensitizing potential of all LLNA:DAE-positive chemicals was estimated as weak. These results suggested that oleic, linoleic, linolenic, undecylenic, and maleic acid had skin-sensitizing potential, and that the LLNA overestimated the skin-sensitizing potential compared to that estimated by the LLNA:DAE.

  17. Positive affect and physical activity: Testing effects on goal setting, activation, prioritisation, and attainment.

    Science.gov (United States)

    Cameron, David S; Bertenshaw, Emma J; Sheeran, Paschal

    2018-02-01

    The present research tested whether incidental positive affect promotes pursuit of physical activity goals. Four key features of goal pursuit were examined - setting physical activity goals (Study 1), goal activation (Study 2), and goal prioritization and goal attainment (Study 3). Participants (N s = 80, 81, and 59, in Studies 1-3, respectively) were randomized to positive affect (joy, hope) or neutral affect (control) conditions in each study. Questionnaire measures of goal level, goal commitment, and means selection (Study 1); a lexical decision task indexed goal activation (Study 2), a choice task captured goal prioritization and MET minutes quantified goal attainment (Study 3). Study 1 showed that positive affect led to a greater number of intended physical activities, and that joy engendered greater willingness to try activities. In Study 2, a positive affect induction led to heightened activation of the physical activity goal compared to the control condition. The joy induction in Study 3 led to greater physical activity, and a trend towards greater goal prioritization. These findings suggest that positive affect enhances the pursuit of physical activity goals. Implications for health behavior theories and interventions are outlined.

  18. Expert Knowledge Influences Decision-Making for Couples Receiving Positive Prenatal Chromosomal Microarray Testing Results.

    Science.gov (United States)

    Rubel, M A; Werner-Lin, A; Barg, F K; Bernhardt, B A

    2017-09-01

    To assess how participants receiving abnormal prenatal genetic testing results seek information and understand the implications of results, 27 US female patients and 12 of their male partners receiving positive prenatal microarray testing results completed semi-structured phone interviews. These interviews documented participant experiences with chromosomal microarray testing, understanding of and emotional response to receiving results, factors affecting decision-making about testing and pregnancy termination, and psychosocial needs throughout the testing process. Interview data were analyzed using a modified grounded theory approach. In the absence of certainty about the implications of results, understanding of results is shaped by biomedical expert knowledge (BEK) and cultural expert knowledge (CEK). When there is a dearth of BEK, as in the case of receiving results of uncertain significance, participants rely on CEK, including religious/spiritual beliefs, "gut instinct," embodied knowledge, and social network informants. CEK is a powerful platform to guide understanding of prenatal genetic testing results. The utility of culturally situated expert knowledge during testing uncertainty emphasizes that decision-making occurs within discourses beyond the biomedical domain. These forms of "knowing" may be integrated into clinical consideration of efficacious patient assessment and counseling.

  19. Impact of relative position vehicle-wind blower in a roller test bench under climatic chamber

    International Nuclear Information System (INIS)

    Fernández-Yáñez, P.; Armas, O.; Martínez-Martínez, S.

    2016-01-01

    Highlights: • Air simulation model was developed for a vehicle test bench under climatic chamber. • Good accuracy between experimental data and simulated values were obtained. • Wind blower-vehicle relative position alters external cooling of after-treatment devices. • Vehicle emission certification can be affected by wind blower-vehicle relative position. - Abstract: In terms of energy efficiency and exhaust emissions control, an appropriate design of cooling systems of climatic chambers destined to vehicle certification and/or perform scientific research is becoming increasingly important. European vehicle emissions certification (New European Driving Cycle, NEDC) establishes the position of the wind-simulation blower at 200 mm above floor level. This height is fixed and kept constant independently of the vehicle tested. The position of the blower with respect to the vehicle can modify the external forced convection under the car, where after-treatment devices are located. Consequently, the performance of such devices could be modified and emission results during the certification cycle could be non-representative of real-world driving conditions. The aim of this work is to study the influence of different wind blower-vehicle relative heights on the air velocity and temperature profiles under the car by means of a simple computational fluid dynamics (CFD) approach. A steady state three-dimensional CFD model was developed and applied to the estimation of the air velocity and temperature profiles inside of a climatic chamber equipped with a vehicle roller (chassis dyno) test bench. The simulations reproduce one steady-state condition from NEDC, specifically the EU17 mode (120 km/h, maximum velocity during the cycle). The cool air propelling temperature was 20 °C (minimum temperature in the NEDC range). Simulations were performed employing the Reynolds-Averaged Navier-Stokes (RANS) approach with the realizable k-ε model to provide closure. Air velocity and

  20. Can ultrasound of plantar plate have normal appearance with a positive drawer test?

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Eloy de Avila [Affiliated Professor, Department of Diagnostic Imaging, Escola Paulista de Medicina, Universidade Federal de São Paulo (EPM-Unifesp), São Paulo (Brazil); Mann, Tania Szejnfeld [Medical Assistant of Medicine and Surgery of the Foot and Ankle Group, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Puchnick, Andrea, E-mail: andrea.ddi@epm.br [Professor and Coordinator of Educational and Research Support, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Tertulino, Franklin de Freitas [Postgraduate Physician, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Cannato, Camila Testoni [Resident Physician, Department of Surgery, EPM-Unifesp, São Paulo (Brazil); Nery, Caio [Associate Professor, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Fernandes, Artur da Rocha Corrêa [Associate Professor, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil)

    2015-03-15

    Highlights: •We evaluate the accuracy of ultrasound to identify and measure the plantar plate. •We correlate ultrasound findings with those of physical examination and MRI. •Ultrasound and MRI measures of plantar plate were positively correlated. •Ultrasound is efficient in identifying and measuring plantar plate. •Ultrasound may complement physical examination. •Young asymptomatic subjects can present a grade I positive drawer test. -- Abstract: Objectives: The aims of this study were (1) to evaluate the reliability of ultrasound (US) examination in the identification and measurement of the metatarsophalangeal plantar plate (MTP-PP) in asymptomatic subjects and (2) to establish the correlation of US findings with those of physical examination and magnetic resonance imaging (MRI), once it is an important tool in the evaluation of the instability syndrome of the second and third rays. Materials and Methods: US examinations of the second and third MTP-PPs were performed in eight asymptomatic volunteers, totaling 32 MTP joints, by three examiners with different levels of experience in musculoskeletal US. Plantar plate dimensions, integrity and echogenicity, the presence of ruptures, and confidence level in terms of structure identification were determined using conventional US. Vascular flow was assessed using power Doppler. US data were correlated with data from physical examination and MRI. Results: MTP-PPs were ultrasonographically identified in 100% of cases, always showing homogeneous hyperechoic features and no detectable vascular flow on power Doppler, with 100% certainty in identification for all examiners. There was excellent US inter-observer agreement for longitudinal measures of second and third toe MTP-PPs and for transverse measures of the second toe MTP-PP. The MTP drawer test was positive for grade 1 MTP instability in 34.4% of joints with normal US results. Transverse MTP-PP measures were significantly higher in individuals with positive

  1. Testes cutâneos de hipersensibilidade imediata com o evoluir da idade Positive skin test and age

    Directory of Open Access Journals (Sweden)

    Wilma Carvalho Neves Forte

    2001-04-01

    Full Text Available OBJETIVO: avaliação da positividade aos testes cutâneos de hipersensibilidade imediata em crianças com asma brônquica e/ou rinite alérgica em diferentes faixas etárias. CASUÍSTICA E MÉTODOS: foi observada a positividade aos testes cutâneos de hipersensibilidade imediata, por testes de puntura, frente a diferentes alérgenos de mesma procedência: poeira total e Dermatophagóides sp, Dermatophagoides pteronyssinus, Dermatophagoides farinae e Blomia tropicalis, Penicillium sp, Alternaria alternata, Cladosporium herbarium, Aspergillus fumigatus, grama bermuda, capim de pasto, epitélio de cão, epitélio de gato, penas, Blatella germanica, lã. Foram selecionadas 713 crianças divididas em grupos conforme a faixa etária: grupo I (6 a 11 meses, II (1 a 3 anos e 11 meses, III (4 a 8 anos e 11 meses e IV (9 a 15 anos. Para análise estatística utilizou-se o cálculo do qui-quadrado. RESULTADOS: o total de diferenças significativas entre os vários grupos foi: I e II = 5; II e III = 5; II e IV = 5; III e IV = 6; I e III = 10 e I e IV = 10 CONCLUSÃO: concluiu-se que a positividade ao teste de hipersensibilidade imediata foi maior com o evoluir da idade, havendo positividade já aos doze meses de vida, sendo esta positividade significativamente maior a partir de quatro anos de idade.OBJECTIVE: to evaluate positive responses to skin tests for immediate hypersensitivity to allergens in children with asthma and rhinitis at different ages. METHOD: we observed positive skin test reactivity in prick tests using fifteen allergens of same origin (total dust and Dermatophagoides sp.; Dermatophagoides pteronyssinus; Dermatophagoides farinae; Blomia tropicalis; Penicillium sp; Alternaria alternata; Cladosporium herbarium; Aspergillus fumigatus; Bermuda grass; forage grass; dog and cat epithelia; feathers; Blatella germanica and wool. We placed 713 selected patients into different age groups - Group I: 6 to 11 months; Group II: 1 to 3 years and 11

  2. Research on Automatic Positioning System of Ultrasonic Testing of Wind Turbine Blade Flaws

    Science.gov (United States)

    Liu, Q. X.; Wang, Z. H.; Long, S. G.; Cai, M.; Cai, M.; Wang, X.; Chen, X. Y.; Bu, J. L.

    2017-11-01

    Ultrasonic testing technology has been used essentially in non-destructive testing of wind turbine blades. However, it is fact that the ultrasonic flaw detection method has inefficiently employed in recent years. This is because the testing result will illustrate a small deviation due to the artificial, environmental and technical factors. Therefore, it is an urgent technical demand for engineers to test the various flaws efficiently and quickly. An automatic positioning system has been designed in this paper to record the moving coordinates and the target distance in real time. Simultaneously, it could launch and acquire the sonic wave automatically. The ADNS-3080 optoelectronic chip is manufactured by Agilent Technologies Inc, which is also utilized in the system. With the combination of the chip, the power conversion module and the USB transmission module, the collected data can be transmitted from the upper monitor to the hardware that could process and control the data through software programming. An experiment has been designed to prove the reliability of automotive positioning system. The result has been validated by comparing the result collected form LABVIEW and actual plots on Perspex plane, it concludes that the system possesses high accuracy and magnificent meanings in practical engineering.

  3. Evaluation of a Positive Youth Development Program Based on the Repertory Grid Test

    Directory of Open Access Journals (Sweden)

    Daniel T. L. Shek

    2012-01-01

    Full Text Available The repertory grid test, based on personal construct psychology, was used to evaluate the effectiveness of Project P.A.T.H.S. (Positive Adolescent Training through Holistic Social Programmes in Hong Kong. One hundred and four program participants (n=104 were randomly invited to complete a repertory grid based on personal construct theory in order to provide both quantitative and qualitative data for measuring self-identity changes after joining the program. Findings generally showed that the participants perceived that they understood themselves better and had stronger resilience after joining the program. Participants also saw themselves as closer to their ideal selves and other positive role figures (but farther away from a loser after joining the program. This study provides additional support for the effectiveness of the Tier 1 Program of Project P.A.T.H.S. in the Chinese context. This study also shows that the repertory grid test is a useful evaluation method to measure self-identity changes in participants in positive youth development programs.

  4. Monitoring the electron beam position at the TESLA test facility free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Kamps, T

    2000-06-14

    The operation of a free electron laser working in the Self Amplified Spontaneous Emission mode (SASE FEL) requires the electron trajectory to be aligned with very high precision in overlap with the photon beam. In order to ensure this overlap, one module of the SASE FEL undulator at the TESLA Test Facility (TTF) is equipped with a new type of waveguide beam position monitor (BPM). Four waveguides are arranged symmetrically around the beam pipe, each channel couples through a small slot to the electromagnetic beam field. The induced signal depends on the beam intensity and on the transverse beam position in terms of beam-to-slot distance. With four slot--waveguide combinations a linear position sensitive signal can be achieved, which is independent of the beam intensity. The signals transduced by the slots are transferred by ridged waveguides through an impedance matching stage into a narrowband receiver tuned to 12 GHz. The present thesis describes design, tests, and implementation of this new type of BPM. (orig.)

  5. Triple vessel coronary artery disease presenting as a markedly positive stress electrocardiographic test and a negative SPECT-TL scintigram: a case of balanced Ischemia

    Directory of Open Access Journals (Sweden)

    Eyal Herzog

    2011-09-01

    Full Text Available The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. We present a case of an 81- year old post-menopausal female who presented to her primary care physician for evaluation of a 6-week dyspnea on exertion and was referred to our institution for exercise stress test with Thallium SPECT with the objective of ruling out coronary artery disease and identifying possible areas of myocardial ischemia. The resting electrocardiogram was unremarkable and stress test evaluation was made. The patient was admitted to the cardiac care unit and coronary artery bypass grafting was successfully performed. The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. Patients undergoing stress tests with these characteristics should undergo careful evaluation and a high level of suspicion should be adopted for further diagnostic assessment of coronary artery disease.

  6. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  7. Flight-Test Evaluation of Kinematic Precise Point Positioning of Small UAVs

    Directory of Open Access Journals (Sweden)

    Jason N. Gross

    2016-01-01

    Full Text Available An experimental analysis of Global Positioning System (GPS flight data collected onboard a Small Unmanned Aerial Vehicle (SUAV is conducted in order to demonstrate that postprocessed kinematic Precise Point Positioning (PPP solutions with precisions approximately 6 cm 3D Residual Sum of Squares (RSOS can be obtained on SUAVs that have short duration flights with limited observational periods (i.e., only ~≤5 minutes of data. This is a significant result for the UAV flight testing community because an important and relevant benefit of the PPP technique over traditional Differential GPS (DGPS techniques, such as Real-Time Kinematic (RTK, is that there is no requirement for maintaining a short baseline separation to a differential GNSS reference station. Because SUAVs are an attractive platform for applications such as aerial surveying, precision agriculture, and remote sensing, this paper offers an experimental evaluation of kinematic PPP estimation strategies using SUAV platform data. In particular, an analysis is presented in which the position solutions that are obtained from postprocessing recorded UAV flight data with various PPP software and strategies are compared to solutions that were obtained using traditional double-differenced ambiguity fixed carrier-phase Differential GPS (CP-DGPS. This offers valuable insight to assist designers of SUAV navigation systems whose applications require precise positioning.

  8. Yoga and positive body image: A test of the Embodiment Model.

    Science.gov (United States)

    Mahlo, Leeann; Tiggemann, Marika

    2016-09-01

    The study aimed to test the Embodiment Model of Positive Body Image (Menzel & Levine, 2011) within the context of yoga. Participants were 193 yoga practitioners (124 Iyengar, 69 Bikram) and 127 university students (non-yoga participants) from Adelaide, South Australia. Participants completed questionnaire measures of positive body image, embodiment, self-objectification, and desire for thinness. Results showed yoga practitioners scored higher on positive body image and embodiment, and lower on self-objectification than non-yoga participants. In support of the embodiment model, the relationship between yoga participation and positive body image was serially mediated by embodiment and reduced self-objectification. Although Bikram practitioners endorsed appearance-related reasons for participating in yoga more than Iyengar practitioners, there were no significant differences between Iyengar and Bikram yoga practitioners on body image variables. It was concluded that yoga is an embodying activity that can provide women with the opportunity to cultivate a favourable relationship with their body. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. False memories for aggressive acts.

    Science.gov (United States)

    Laney, Cara; Takarangi, Melanie K T

    2013-06-01

    Can people develop false memories for committing aggressive acts? How does this process compare to developing false memories for victimhood? In the current research we used a simple false feedback procedure to implant false memories for committing aggressive acts (causing a black eye or spreading malicious gossip) or for victimhood (receiving a black eye). We then compared these false memories to other subjects' true memories for equivalent events. False aggressive memories were all too easy to implant, particularly in the minds of individuals with a proclivity towards aggression. Once implanted, the false memories were indistinguishable from true memories for the same events, on several dimensions, including emotional content. Implications for aggression-related memory more generally as well as false confessions are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Etiology and Incidence of positive Microbiological tests in the Department of Pneumology

    Directory of Open Access Journals (Sweden)

    Carmela Mazzone

    2010-06-01

    Full Text Available The support of microbiological diagnosis for the management of the lower respiratory tract infections is of great utility. It is known, however, that for a correct therapeutic approach is essential to obtain clinical data and images diagnostic. Sometimes, in fact, to important clinical symptoms can coincide with microbiological results little worth, or the isolation from a sputum of certain bacteria, can be an expression of colonization or trivial contamination.The objective of this work was to evaluate the frequency of bacterial species responsible for respiratory tract infections, through direct (culture and indirect (serology methods. Between October 2007 - October 2008, 192 sputum cultures were examined, from the Department of Pneumology and out-patients.The isolation of bacterial strains was performed by seeding samples on the following media (Dasit: Columbia blood Agar (A. CNA, mannitol salt A., Wurtz lactose A., Sabouraud A., enriched chocolate A. + bacitracin. For serological tests, immunoassays in microplates (Vircell were used. The data show that of 192 samples deriving from Department of Pneumology, 41 (22% were positive, while among the out-patient samples, the percentage of positive cultures was 41% (20 positives on the total of 49 samples.The bacteria more frequently isolated in the department of Pneumology, was Pseudomonas aeruginosa (n.8 while in out-patients was Escherichia coli (n.8. Serological tests resulted positive for anti-Mycoplasma pneumoniae antibodies in 3 cases, and for anti-Chlamydia pneumoniae in one case, compared to 53 negative samples. The findings that over 75% of cultures have demonstrated negative results, is suggestive of an origin non-bacterial infections of the lower respiratory tract.Among the bacterial isolates are predominant “opportunistic bacteria” (46% presumably responsible of nosocomial infections, while in the out-patients are Enterobacteriaceae the prevalent microrganisms isolated.

  11. [Necessity of repeated roll test in horizontal semicircular canalithasis positioned diagnosis].

    Science.gov (United States)

    Lu, H H; Zhao, Y; Chen, T S; Xu, K X; Wang, W; Liu, Q; Wen, C; Li, S S; Li, X J; Han, X; Lin, P

    2016-04-07

    To investigate the influence of repeated roll test in horizontal semicircular canalithasis(HSC-Can) positioned diagnosis, so as to investigate the cecessity of repeated roll test. The patients with a chief complaint of positional vertigo accepted two consecutive cycles roll test, the evoked nystagmus characteristics of each cycle recorded by video-nystagmuograph(VNG), whose direction, intensity, time and other parameters characteristics were analyzed in 51 HSC-Can. Horizontal nystagmus in the same direction with turning were induced in HSC-Can roll test. In 51 HSC-Can, roll test cycle 1 and cycle 2 induced nystagmus same strength side in 26 cases(51.0%), of which 19 cases with stronger nystagmus intensity in cycle 2, another 7 cases were weaker; the opposite strength side of the two loops induced nystagmus, and cycle 1 evoked nystagmus intensity were weaker than cycle 2, based on cycle 2 results determined HSC-Can affected side in 25 cases (49.0%). Lesion and normal side in cycle 1 induced nystagmus duration (x±s, the same below) were (13.4±11.5)s and (14.1±9.9)s, respectively intensity (18.1±22.4)°/s and (13.0±12.0)°/s; as in cycle 2 induced nystagmus duration was (20.7±10.2)s and (18.0±12.0)s, strength respectively(40.4±28.0)°/s and (15.6 ±11.2)°/s. Cycle 2 ipsilateral rotor position evoked nystagmus showed longer duration and stronger intensity than cycle 1. Between two cycle induced ipsilateral nystagmus duration, intensity differences were statistically significant (t values were -4.233 and -5.154, P=0.000). 51 HSC-Can patients, 44 patients selected repositioning maneuver, after 1-2 times of maneuver, 41 cases (93.2%) showed complete resolution of symptoms, all cases's symptoms were improved; other 7 patients selected medication only. The proposed suspicious HSC-Can patients should receive at least two cycles roll test, and mainly in the second cycle could determine the location of the responsible semicircular canals.

  12. Prenatal Testing for Adult-Onset Conditions: the Position of the National Society of Genetic Counselors.

    Science.gov (United States)

    Hercher, Laura; Uhlmann, Wendy R; Hoffman, Erin P; Gustafson, Shanna; Chen, Kelly M

    2016-12-01

    Advances in genetic testing and the availability of such testing in pregnancy allows prospective parents to test their future child for adult-onset conditions. This ability raises several complex ethical issues. Prospective parents have reproductive rights to obtain information about their fetus. This information may or may not alter pregnancy management. These rights can be in conflict with the rights of the future individual, who will be denied the right to elect or decline testing. This paper highlights the complexity of these issues, details discussions that went into the National Society of Genetic Counselors (NSGC) Public Policy Task Force's development of the Prenatal testing for Adult-Onset Conditions position statement adopted in November 2014, and cites relevant literature on this topic through December 2015. Issues addressed include parental rights and autonomy, rights of the future child, the right not to know, possible adverse effects on childhood and the need for genetic counseling. This paper will serve as a reference to genetic counselors and healthcare professionals when faced with this situation in clinical practice.

  13. A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests

    Directory of Open Access Journals (Sweden)

    Yousok Kim

    2013-09-01

    Full Text Available Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS. The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape of the test specimen using system identification methods (frequency domain decomposition, FDD. By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape with the 3D measurements.

  14. Neural Network Target Identification System for False Alarm Reduction

    Science.gov (United States)

    Ye, David; Edens, Weston; Lu, Thomas T.; Chao, Tien-Hsin

    2009-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

  15. Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.

    Science.gov (United States)

    Kramer, Andreas H; Couillard, Philippe; Bader, Ryan; Dhillon, Peter; Kutsogiannis, Demetrios J; Doig, Christopher J

    2017-08-01

    Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O 2 ) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O 2 (PO 2 ) reduction. We performed a multicenter study assessing consecutive apnea tests in 14 intensive care units (ICUs) in two cities utilizing differing protocols. In one city, O 2 catheters are placed and arterial blood gases (ABGs) performed at intervals determined by the attending physician. In the other city, a resuscitation bag with CPAP valve is attached