  1. Sea/Lake Water Air Conditioning at Naval Facilities.

    Science.gov (United States)

    1980-05-01

    r-AO89 262 CIVIL ENGINEERING LAS (NAVY) PONT HUJENEME CA F/6 13/1 SEA/LAKF WATER AIR CONDITIONING AT N4AVAL FACILITIES.u MAY S0 .J B CIAN...AROICC. Brooklyn NY: CO; C’ode (NP (LCDR ATJ Stewart): C’ode 10)28. RDT&ELO. Philadelphia PA: Code III (Castranovo) Philadelphia. PA: Design Div. (R...Governor’s Council On Energy) NEW MEXICO SOLAR ENERGY INST. Dr. Zwibcl Las Cruces NM NY CITY COMMUNITY COLLEGE BROOKLYN , NY (LIBRARY) NYS ENERGY OFFICE

  2. 40 CFR 86.161-00 - Air conditioning environmental test facility ambient requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Air conditioning environmental test... conditioning environmental test facility ambient requirements. The goal of an air conditioning test facility is..., within the test cell, during all phases of the air conditioning test sequence to 95 ±2 °F on average and...

  3. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research FacilityFacilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  4. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  5. Energetics Conditioning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Conditioning Facility is used for long term and short term aging studies of energetic materials. The facility has 10 conditioning chambers of which 2...

  6. Energetics Conditioning Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Energetics Conditioning Facility is used for long term and short term aging studies of energetic materials. The facility has 10 conditioning chambers of which 2...

  7. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  8. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  9. REACH. Air Conditioning Units.

    Science.gov (United States)

    Garrison, Joe; And Others

    As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of air conditioning. The instructional units focus on air conditioning fundamentals, window air conditioning, system and installation, troubleshooting and…

  10. REACH. Air Conditioning Units.

    Science.gov (United States)

    Garrison, Joe; And Others

    As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of air conditioning. The instructional units focus on air conditioning fundamentals, window air conditioning, system and installation, troubleshooting and…

  11. Reverse Ballistic Air Gun Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This custom-designed facility houses a suite of three air guns capable of generating accelerations up to 100,000 Gs and velocities up to 2,000 ft/s. In addition to a...

  12. Reverse Ballistic Air Gun Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This custom-designed facility houses a suite of three air guns capable of generating accelerations up to 100,000 Gs and velocities up to 2,000 ft/s. In addition to...

  13. Water spray interaction with air-steam mixtures under containment spray conditions: experimental study in the TOSQAN facility

    Energy Technology Data Exchange (ETDEWEB)

    Porcheron, E.; Lemaitre, P.; Malet, J.; Nuboer, A.; Brun, P.; Bouilloux, L.; Vendel, J. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Direction de la Surete des Usines, des laboratoires, des transports et des dechets, Saclay, BP 68 - 91192 Gif-sur-Yvette cedex (France)

    2005-07-01

    Full text of publication follows: During the course of an hypothetical severe accident in a Pressurized Water Reactor (PWR), hydrogen can be produced by the reactor core oxidation and distributed into the reactor containment according to convection flows and steam wall condensation. In order to assess the risk of detonation generated by a high local hydrogen concentration, hydrogen distribution in the containment has to be known. The TOSQAN experimental program has been created to simulate typical accidental thermal hydraulic flow conditions in the reactor containment. The present work is devoted to study the interaction of a water spray injection used as a mitigation mean in order to reduce containment pressure and to produce a mixing of air, steam and hydrogen induced by spray entrainment and condensation on droplet. In order to have a better understanding of physical phenomena, we need to make a detailed characterization of the spray and the gas. The TOSQAN facility that is highly instrumented with non-intrusive diagnostics consists in a closed cylindrical vessel (7 m{sup 3} volume, 4 m high, 1.5 m i.d.) into which steam is injected. Water droplets size is measured in the vessel by the Interferometric Laser Imaging for Droplet Sizing technique. Droplet velocity is obtained by Particle Image Velocimetry and Laser Doppler Velocimetry, and droplet temperature is measured by global rainbow refractometry. Gas concentration measurements are performed by Spontaneous Raman Scattering. The walls of the vessel are thermostatically controlled by heated oil circulation. Inner spray system that is located on the top of the enclosure on the vertical axis, is composed of a single nozzle producing a full cone water spray. Spray test scenario consists of water spray injection in TOSQAN that is first pressurized with a steam injection (steam injection is stopped before spray injection). Water spray falling into the sump is removed to avoid accumulation and evaporation

  14. Air-Conditioning Mechanic.

    Science.gov (United States)

    Marine Corps Inst., Washington, DC.

    This student guide, one of a series of correspondence training courses designed to improve the job performance of members of the Marine Corps, deals with the skills needed by air conditioning mechanics. Addressed in the four chapters, or lessons, of the manual are the following topics: principles of air conditioning, refrigeration components as…

  15. EPA Facility Registry Service (FRS): AIRS_AFS Sub Facilities

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Facility System (AFS) contains compliance and permit data for stationary sources regulated by EPA, state and local air pollution agencies. The sub facility...

  16. Air regenerating and conditioning

    Science.gov (United States)

    Grishayenkov, B. G.

    1975-01-01

    Various physicochemical methods of regenerating and conditioning air for spacecraft are described with emphasis on conditions which affect efficiency of the system. Life support systems used in closed, hermetically sealed environments are discussed with references to actual application in the Soviet Soyuz and Voskhod manned spacecraft. Temperature and humidity control, removal of carbon dioxide, oxygen regeneration, and removal of bacteria and viruses are among the factors considered.

  17. Air conditioning boxes

    Energy Technology Data Exchange (ETDEWEB)

    1981-11-01

    Technical data, layout and function of air conditioning boxes by 6 German producers are described. The boxes cover a volume flow range of 1000 to 100000 m/sup 3//h. All boxes are equipped with heat exchangers, moisturizers, filters, and control elements.

  18. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  19. Air Defense Radar Operations Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Facility consists of laboratories, experimental test equipment including state-of-theart test bed radar, and test ranges. The facilities are used to design, develop,...

  20. Air Defense Radar Operations Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Facility consists of laboratories, experimental test equipment including state-of-theart test bed radar, and test ranges. The facilities are used to design, develop,...

  1. Air Conditioning Does Reduce Air Pollution Indoors

    Science.gov (United States)

    Healy, Bud

    1970-01-01

    Report of the winter meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. Subjects covered are--(1) title subject, (2) predictions for the human habitat in 1994, (3) fans, and (4) fire safety in buildings. (JW)

  2. Air Conditioning Does Reduce Air Pollution Indoors

    Science.gov (United States)

    Healy, Bud

    1970-01-01

    Report of the winter meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. Subjects covered are--(1) title subject, (2) predictions for the human habitat in 1994, (3) fans, and (4) fire safety in buildings. (JW)

  3. Air Conditioning Overflow Sensor

    Science.gov (United States)

    1996-01-01

    The Technology Transfer Office at Stennis Space Center helped a local inventor develop a prototype of an attachment for central air conditioners and heat pumps that helps monitor water levels to prevent condensation overflow. The sensor will indicate a need for drain line maintenance and prevent possible damage caused by drain pan water spillover. An engineer in the Stennis Space Center prototype Development Laboratory used SSC sensor technology in the development of the sensor.

  4. Air Conditioning Overflow Sensor

    Science.gov (United States)

    1996-01-01

    The Technology Transfer Office at Stennis Space Center helped a local inventor develop a prototype of an attachment for central air conditioners and heat pumps that helps monitor water levels to prevent condensation overflow. The sensor will indicate a need for drain line maintenance and prevent possible damage caused by drain pan water spillover. An engineer in the Stennis Space Center prototype Development Laboratory used SSC sensor technology in the development of the sensor.

  5. SOLAR AIR CONDITIONING OF BUILDING

    Directory of Open Access Journals (Sweden)

    Debrayan Bravo Hidalgo

    2015-04-01

    Full Text Available Air Conditioning with renewable energy is a key issue in the region's energy policy. The high temperatures usually attributed to climate change and the increase of the standard of living in society continues increasing energy demand in order to establish the conditions for thermal comfort in buildings. Solar air conditioning, although it contains a mature technology, its level of market introduction and acceptance by designers of buildings is exhaustive. This paper discusses the feasibility of these projects, identifies non-technological type barriers that hinders such use and implementation of solar energy for air conditioning systems, and finally, it approaches some criteria and recommendations to overcome these obstacles.

  6. Physical Sciences Facility Air Emission Control Equivalency Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, David M.; Belew, Shan T.

    2008-10-17

    This document presents the adequacy evaluation for the application of technology standards during design, fabrication, installation and testing of radioactive air exhaust systems at the Physical Sciences Facility (PSF), located on the Horn Rapids Triangle north of the Pacific Northwest National Laboratory (PNNL) complex. The analysis specifically covers the exhaust portion of the heating, ventilation and air conditioning (HVAC) systems associated with emission units EP-3410-01-S, EP-3420-01-S and EP 3430-01-S.

  7. Flow in air conditioned rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1974-01-01

    Flow in air conditioned r ooms is examined by means of model experiments . The different gearnetries giving unsteady, steady three- dimensional and steady twodimensional flow are determined . Velacity profiles and temperature profiles are measured in some of the geometries. A numerical solution...... of the flow equations is demonstrated and the flow in air conditioned rooms in case of steady two dimensional flow is predi cted. Compari son with measured results is shown i n the case of small Archimedes numbers, and predictions are shown at high Archimedes numbers. A numerical prediction of f low and heat...

  8. Health effects of air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Molina, C.; Caillaud, D.

    The air conditioning used in residential or commercial buildings (offices, hotels, sterile areas of hospitals, computer and electronics industries) is responsible for a certain number of well identified ailments which can be classified in three groups: infections (legionnaires'disease, ornithosis), allergies (mainly respiratory) eg. rhinitis, asthma, alveolitis but also Monday morning illness or humidifier fever, various functional disorders grouped under the name Sick Building Syndrome. To avoid these problems, a certain number of recommendations may be made. They concern: installation of air conditioning, humidification which is the cause of bacterial and fungal contamination, filtration, monitoring of the installation by qualitative and quantitative measurements, maintenance. The legal problems relating to these illnesses, the responsibility for which is ultimately laid at the door of the installers, should also be mentioned. Allergies are recognized to be of professional origin in Table 66 of allergic illnesses issued by the Social Security.

  9. Solar air-conditioning. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    Within the 3rd International Conference on solar air-conditioning in Palermo (Italy) at 30th September to 2nd October, 2009 the following lectures were held: (1) Removal of non-technological barriers to solar cooling technology across Southern European islands (Stefano Rugginenti); (2) The added economic and environmental value of solar thermal systems in microgrids with combined heat and power (Chris Marney); (3) Australian solar cooling interest group (Paul Kohlenbach); (4) Designing of a technology roadmap for solar assisted air conditioning in Austria (Hilbert Focke); (5) Solar cooling in the new context of renewable policies at European level (Raffaele Piria); (6) Prototype of a solar driven steam jet ejector chiller (Clemens Pollerberg); (7) New integrated solar air conditioning system (Joan Carlos Bruno); (8) Primary energy optimised operation of solar driven desiccant evaporative cooling systems through innovative control strategies; (9) Green chiller association (Uli Jakob); (10) Climate Well {sup registered} (Olof Hallstrom); (11) Low capacity absorption chillers for solar cooling applications (Gregor Weidner); (12) Solar cooling in residential, small scale commercial and industrial applications with adsorption technology (Walter Mittelbach); (13) French solar heating and cooling development programme based on energy performance (Daniel Mugnier); (14) Mirrox fresnel process heat collectors for industrial applications and solar cooling (Christian Zahler); (15) Modelling and analyzing solar cooling systems in polysun (Seyen Hossein Rezaei); (16) Solar cooling application in Valle Susa Italy (Sufia Jung); (17) Virtual case study on small solar cooling systems within the SolarCombi+Project (Bjoern Nienborg); (18) Design of solar cooling plants under uncertainty (Fernando Dominguez-Munoz); (19) Fast pre-design of systems using solar thermally driven chillers (Hans-Martin Henning); (20) Design of a high fraction solar heating and cooling plant in southern

  10. High Energy Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these

  11. Improving efficiency of existing air-conditioning

    Science.gov (United States)

    Obler, H. D.

    1977-01-01

    Inexpensive duct work changes improves hot-and-cold deck air conditioning units. Energy cost of reheating cooled air can be eliminated by tying all cold air decks to one air-conditioning unit and all hot decks to another. Resultant energy savings are easily possible with two or more units.

  12. Aerometric Information Retrieval System/AIRS Facility Subsystem (AIRS/AFS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Aerometric Information Retrieval System/AIRS Facility Subsystem (AIRS/AFS) is a database that provides information on air releases from various stationary...

  13. Fuel Conditioning Facility Electrorefiner Process Model

    Energy Technology Data Exchange (ETDEWEB)

    DeeEarl Vaden

    2005-10-01

    The Fuel Conditioning Facility at the Idaho National Laboratory processes spent nuclear fuel from the Experimental Breeder Reactor II using electro-metallurgical treatment. To process fuel without waiting for periodic sample analyses to assess process conditions, an electrorefiner process model predicts the composition of the electrorefiner inventory and effluent streams. For the chemical equilibrium portion of the model, the two common methods for solving chemical equilibrium problems, stoichiometric and non stoichiometric, were investigated. In conclusion, the stoichiometric method produced equilibrium compositions close to the measured results whereas the non stoichiometric method did not.

  14. Condition Monitoring of Large-Scale Facilities

    Science.gov (United States)

    Hall, David L.

    1999-01-01

    This document provides a summary of the research conducted for the NASA Ames Research Center under grant NAG2-1182 (Condition-Based Monitoring of Large-Scale Facilities). The information includes copies of view graphs presented at NASA Ames in the final Workshop (held during December of 1998), as well as a copy of a technical report provided to the COTR (Dr. Anne Patterson-Hine) subsequent to the workshop. The material describes the experimental design, collection of data, and analysis results associated with monitoring the health of large-scale facilities. In addition to this material, a copy of the Pennsylvania State University Applied Research Laboratory data fusion visual programming tool kit was also provided to NASA Ames researchers.

  15. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  16. Air Conditioning, Heating, and Refrigeration. Competency-Based Curriculum Manual.

    Science.gov (United States)

    Gourley, Frank A., Jr.

    This manual was developed to serve as an aid to administrators and instructors involved with postsecondary air conditioning, heating, and refrigeration programs. The first of six chapters contains general information on program implementation, the curriculum design, facilities and equipment requirements, and textbooks and references. Chapter 2…

  17. Concentrated Solar Air Conditioning for Buildings Project

    Science.gov (United States)

    McLaughlin, Rusty

    2010-01-01

    This slide presentation reviews project to implement the use of solar power to provide air conditioning for NASA buildings. Included is an overall conceptual schematic, and an diagram of the plumbing and instrumentation for the project. The use of solar power to power air conditioning in buildings, particularly in the Southwest, could save a significant amount of money. DOD studies have concluded that air conditioning accounts for 30-60% of total energy expenditures.

  18. No-reheat air-conditioning

    Science.gov (United States)

    Obler, H. D.

    1980-01-01

    Air conditioning system, for environmentally controlled areas containing sensitive equipment, regulates temperature and humidity without wasteful and costly reheating. System blends outside air with return air as dictated by various sensors to ensure required humidity in cooled spaces (such as computer room).

  19. Air Conditioning. Performance Objectives. Intermediate Course.

    Science.gov (United States)

    Long, William

    Several intermediate performance objectives and corresponding criterion measures are listed for each of seven terminal objectives for an intermediate air conditioning course. The titles of the seven terminal objectives are Refrigeration Cycle, Job Requirement Skills, Air Conditioning, Trouble Shooting, Performance Test, Shop Management, and S.I.E.…

  20. HEATING AND AIR CONDITIONING EDUCATIONAL PROGRAM.

    Science.gov (United States)

    Lennox Industries, Inc., Marshalltown, IA.

    INCREASED MOTIVATION, INCREASED INITIAL COMPREHENSION, AND INCREASED RETENTION ARE THE PRIME GOALS OF THE LENNOX HEATING AND AIR CONDITIONING EDUCATION PROGRAM. IT IS A COMPLETE PROGRAM WITH ALL THE TEACHING TOOLS REQUIRED TO PRODUCE A KNOWLEDGEABLE HEATING AND AIR-CONDITIONING INSTALLER OR SERVICE MAN. THIS INSTRUCTIONAL PROGRAM IS DESIGNED…

  1. Air Conditioning and Heating Technology--II.

    Science.gov (United States)

    Gattone, Felix

    Twenty-eight chapters and numerous drawings provide information for instructors and students of air conditioning and heating technology. Chapter 1 lists the occupational opportunities in the field. Chapter 2 covers the background or development of the industry of air conditioning and heating technology. Chapter 3 includes some of the principle…

  2. Air Conditioning. FOS: Fundamentals of Service.

    Science.gov (United States)

    Employment and Training Administration (DOL), Washington, DC. Office of Youth Programs.

    This manual on air conditioning is one of a series of power mechanics texts and visual aids covering theory of operation, diagnosis, and repair. Information is presented for use by vocational students and teachers as well as shop servicemen and laymen. Focus is on air conditioning systems for mobile machines, but most of the information also…

  3. Air Conditioning. Performance Objectives. Intermediate Course.

    Science.gov (United States)

    Long, William

    Several intermediate performance objectives and corresponding criterion measures are listed for each of seven terminal objectives for an intermediate air conditioning course. The titles of the seven terminal objectives are Refrigeration Cycle, Job Requirement Skills, Air Conditioning, Trouble Shooting, Performance Test, Shop Management, and S.I.E.…

  4. Air Conditioning and Heating Technology--II.

    Science.gov (United States)

    Gattone, Felix

    Twenty-eight chapters and numerous drawings provide information for instructors and students of air conditioning and heating technology. Chapter 1 lists the occupational opportunities in the field. Chapter 2 covers the background or development of the industry of air conditioning and heating technology. Chapter 3 includes some of the principle…

  5. A novel summer air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Al-Nimr, M.A.; Abu Nabah, B.A.; Naji, M. [Jordan Univ. of Science and Technology, Irbid (Jordan). Dept. of Mechanical Engineering

    2002-09-01

    A novel summer air conditioning system is proposed. The proposed system modifies the work of the classical evaporative summer air conditioning system. The performance of the proposed system is investigated quantitatively, and a comparison between the performance of the classical and the modified systems is conducted. It is found that the modified system improves the performance of the classical one by about 100%. (author)

  6. Recent air conditioning systems of shopping buildings

    Energy Technology Data Exchange (ETDEWEB)

    Nagashima, Hironori

    1988-11-05

    In the air conditioning system in the shopping building, both the distributed air conditioning and DDC control methods have been increasingly adopted. The distributed air conditioning method, with a microcomputer mounted thereon, has attained the level sufficiently corresponding to the large scale building. While, the DDC control method, like the distributed air conditioning method, is considerably effective on the system having many surveillance control items. To engineer the energy conservation of air conditioning system in the shopping building, the utilization of atmospheric air as natural energy and control method for the ambient room condition reexamined must be studied. For the former, the atmospheric air intake quantity control to dilute CO and CO/sub 2/, and atmospheric air purge system prior to the air cooling are useful. While for the latter, the control method aiming at the comfort range, so called zero energy band control method is recommendable. Further for the temperature and humidity control, the DDC control by local controller is useful. 6 figures, 1 table.

  7. Cold Vacuum Drying Facility Stack Air Sampling System Qualification Tests

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.

    2001-01-24

    This report documents tests that were conducted to verify that the air monitoring system for the Cold Vacuum Drying Facility ventilation exhaust stack meets the applicable regulatory criteria regarding the placement of the air sampling probe, sample transport, and stack flow measurement accuracy.

  8. Operation technology of air treatment system in nuclear facilities

    CERN Document Server

    Chun, Y B; Hwong, Y H; Lee, H K; Min, D K; Park, K J; Uom, S H; Yang, S Y

    2001-01-01

    Effective operation techniques were reviewed on the air treatment system to protect the personnel in nuclear facilities from the contamination of radio-active particles and to keep the environment clear. Nuclear air treatment system consisted of the ventilation and filtering system was characterized by some test. Measurement of air velocity of blowing/exhaust fan in the ventilation system, leak tests of HEPA filters in the filtering, and measurement of pressure difference between the areas defined by radiation level were conducted. The results acquired form the measurements were reflected directly for the operation of air treatment. In the abnormal state of virus parts of devices composted of the system, the repairing method, maintenance and performance test were also employed in operating effectively the air treatment system. These measuring results and techniques can be available to the operation of air treatment system of PIEF as well as the other nuclear facilities in KAERI.

  9. Thermal conditions and perceived air quality in an air-conditioned auditorium

    Science.gov (United States)

    Polednik, Bernard; Guz, Łukasz; Skwarczyński, Mariusz; Dudzińska, Marzenna R.

    2016-07-01

    The study reports measurements of indoor air temperature (T) and relative humidity (RH), perceived air quality (PAQ) and CO2, fine aerosol particle number (PN) and mass (PM1) concentrations in an air conditioned auditorium. The measurements of these air physical parameters have been carried out in the unoccupied auditorium with the air conditioning system switched off (AC off mode) and in the unoccupied and occupied auditorium with the air conditioning system switched off during the night and switched on during the day (AC on/off mode). The average indoor air thermal parameters, CO2 concentration and the PAQ value (in decipols) were elevated, while average PM1 concentration was lower in the AC on/off mode. A statistically significant (p quality deteriorates along with the variation of the indoor air microclimate and room occupation. This, in turn, may adversely affect the comfort and productivity of the users of air conditioned premises.

  10. Carbon Emissions from air-Conditioning

    OpenAIRE

    Rajesh Kumar

    2013-01-01

    This paper explores electricity consumption and carbon emissions associated with air-conditioning. The total heat load of a room fitted with air conditioner of 1.5 ton capacity has been calculated by calculating conduction and ventilation losses. Solar heat gain and internal gain were taken as the other two parameters for the total heat calculation.

  11. Carbon Emissions from air-Conditioning

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2013-01-01

    Full Text Available This paper explores electricity consumption and carbon emissions associated with air-conditioning. The total heat load of a room fitted with air conditioner of 1.5 ton capacity has been calculated by calculating conduction and ventilation losses. Solar heat gain and internal gain were taken as the other two parameters for the total heat calculation.

  12. Air conditioning for data processing system areas

    Directory of Open Access Journals (Sweden)

    Hernando Camacho García

    2011-06-01

    Full Text Available The appropiate selection of air conditioners for data processing system areas requires the knowledge of the environmental desing conditions, the air conditioning systems succssfully used computer and the cooling loads to handle. This work contains information about a wide variety of systems designed for computer room applications. a complete example of calculation to determine the amount of heat to be removed for satisfactory operation, is also included.

  13. Reduced bleed air extraction for DC-10 cabin air conditioning

    Science.gov (United States)

    Newman, W. H.; Viele, M. R.; Hrach, F. J.

    1980-01-01

    It is noted that a significant fuel savings can be achieved by reducing bleed air used for cabin air conditioning. Air in the cabin can be recirculated to maintain comfortable ventilation rates but the quality of the air tends to decrease due to entrainment of smoke and odors. Attention is given to a development system designed and fabricated under the NASA Engine Component Improvement Program to define the recirculation limit for the DC-10. It is shown that with the system, a wide range of bleed air reductions and recirculation rates is possible. A goal of 0.8% fuel savings has been achieved which results from a 50% reduction in bleed extraction from the engine.

  14. Heating, ventilation and air conditioning system modelling

    Energy Technology Data Exchange (ETDEWEB)

    Whalley, R.; Abdul-Ameer, A. [British University in Dubai (United Arab Emirates)

    2011-03-15

    Heating, ventilation and air conditioning modelling methods, for large scale, spatially dispersed systems are considered. Existing techniques are discussed and proposals for the application of novel analysis approaches are outlined. The use of distributed-lumped parameter procedures enabling the incorporation of the relatively concentrated and significantly dispersed, system element characteristics, is advocated. A dynamic model for a heating, ventilation and air conditioning system comprising inlet and exhaust fans, with air recirculation, heating/cooling and filtration units is presented. Pressure, airflow and temperature predictions within the system are computed following input, disturbance changes and purging operations. The generalised modelling advancements adopted and the applicability of the model for heating, ventilation and air conditioning system simulation, re-configuration and diagnostics is emphasised. The employment of the model for automatic, multivariable controller design purposes is commented upon. (author)

  15. Absorption air conditioning press kit: natural gas air conditioning - market shows Gaz de France's falling back, technologies - absorption heat pumps are coming to France, heat recovery - free energy for a waste processing facility, natural gas air conditioning - ideal temperature in the departments of a supermarket, teaching - an absorption machinery in a college of Marseille; Dossier Absorption: clim au gaz - le marche accuse le repli de gaz de France, technologies - les pompes a chaleur a absorption arrivent en France, recuperation de chaleur - de l'energie gratuite pour un centre de traitement des dechets, climatisation au gaz naturel - temperature ideale dans les rayons d'un supermarche, enseignement - une machine a absorption dans un lycee de Marseille

    Energy Technology Data Exchange (ETDEWEB)

    Nicolas, J.; Maes, P.

    2005-03-01

    The reorganization of Gaz de France (GdF) company (the former historical French gas utility) in the framework of the opening of energy markets has deeply changed the natural gas air conditioning sector. The professionals now have to promote this solution without the active sustain of GdF. The natural gas air conditioning technologies should develop in Europe in the coming years. The electricity prices and the necessity to reduce the summer consumption play in favor of natural gas. The ability of absorption air conditioning to valorize various heat sources is in good agreement with the sustainable development prospects and is one of the promotion way chosen in France by absorption equipment retailers. This press kit about absorption air conditioning systems comprises 5 articles dealing with: the natural gas air conditioning market in France, the start-up of absorption heat pumps commercialization in France, the in-situ valorization of wood wastes for the space heating and air conditioning at the municipal waste sorting facility of Plantaurel (Ariege, France), the natural gas air conditioning of a supermarket in Gap (Southern Alps, France), and a pedagogical gas air-conditioning facility in a technical college of Marseille (France). (J.S.)

  16. Air conditioning. Special issue; Luchtbehandeling. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Montague, M.; Liew, R.; Daruwalla, H.; Wenzek, J. [AAF International, Amsterdam (Netherlands); De Lede, F. [Klimaatinstallaties Kats en Waalwijk, Gorinchem (Netherlands); Nuijten, O. [ISSO, Rotterdam (Netherlands); Van Pelt, J. [Skiw, Nieuwegein (Netherlands); Arts, J. [Imtech Utiliteit West, Capelle a/d IJssel (Netherlands); Vollebregt, R.; Hoeffnagel, R.; Smorenburg, P.; Bijman, J.

    2007-02-15

    In eight articles attention is paid to several aspects of air conditioning and related systems: the perfect filter case for gas filtration, innovative cooling for computer rooms, thermal comfort in offices, standardization of legionella prevention in climate installations and cooling towers, air quality and energy consumption of integrated units, new air conditioners in the Dutch market. [Dutch] In acht artikelen wordt aandacht besteed aan verschillende aspecten van luchtbehandeling en verwante systemen: de perfecte filtercassette vor gasfasefiltratie, innovatieve koeling in computerruimte, hoog comfort in bestaande kantoren, de in ontwikkeling zijn ISSO-publicatie 55.3 voor legionellapreventie in klimaatinstallaties, legionellapreventie bij comfortkoeling, luchtbehandeling met geintegreerde units, en nieuwe luchtbehandelingskasten voor de Nederlandse markt.

  17. Solid waste transuranic storage and assay facility indoor air sampling

    Energy Technology Data Exchange (ETDEWEB)

    Pingel, L.A., Westinghouse Hanford

    1996-08-20

    The purpose of the study is to collect and analyze samples of the indoor air at the Transuranic Storage and Assay Facility (TRUSAF), Westinghouse Hanford. A modified US EPA TO-14 methodology, using gas chromatography/mass spectrography, may be used for the collection and analysis of the samples. The information obtained will be used to estimate the total release of volatile organic compounds from TRUSAF to determine the need for air emmission permits.

  18. Local Air Quality Conditions and Forecasts

    Science.gov (United States)

    ... Monitor Location Archived Maps by Region Canada Air Quality Air Quality on Google Earth Links A-Z About AirNow AirNow International Air Quality Action Days / Alerts AirCompare Air Quality Index (AQI) ...

  19. The Effect of Computers on School Air-Conditioning.

    Science.gov (United States)

    Fickes, Michael

    2000-01-01

    Discusses the issue of increased air-conditioning demand when schools equip their classrooms with computers that require enhanced and costlier air-conditioning systems. Air-conditioning costs are analyzed in two elementary schools and a middle school. (GR)

  20. The Effect of Computers on School Air-Conditioning.

    Science.gov (United States)

    Fickes, Michael

    2000-01-01

    Discusses the issue of increased air-conditioning demand when schools equip their classrooms with computers that require enhanced and costlier air-conditioning systems. Air-conditioning costs are analyzed in two elementary schools and a middle school. (GR)

  1. 2015 German refrigeration and air conditioning meeting. Abstracts; Deutsche Kaelte- und Klimatagung 2015. Kurzfassungen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-07-01

    The volume contains the abstracts of the 2015 German refrigeration and air conditioning meeting in 5 chapters: cryo-technology, fundamentals of materials for refrigeration engineering and heat pump technology, facilities and components for the refrigeration and heat pump technology; application of refrigeration engineering; air conditioning technology and heat pump application.

  2. Air Conditioning and Refrigeration. Book Two.

    Science.gov (United States)

    Wantiez, Gary W.

    This curriculum guide (book II), along with book I, is designed to provide students with the basic skills for an occupation in air conditioning and refrigeration. Six major areas are included, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Electricity (fundamentals of electricity,…

  3. Air Conditioning and Refrigeration Supplementary Units.

    Science.gov (United States)

    Winston, Del; And Others

    This document contains supplemental materials for special needs high school students intended to facilitate their mainstreaming in regular air conditioning and refrigeration courses. Teacher's materials precede the materials for students and include general notes for the instructor, additional suggestions, two references, a questionnaire on the…

  4. Air Conditioning and Refrigeration Book IV.

    Science.gov (United States)

    Eckes, William; Fulkerson, Dan

    This publication is the concluding text in a four-part curriculum for air conditioning and refrigeration. Materials in Book 4 are designed to complement theoretical and functional elements in Books 1-3. Instructional materials in this publication are written in terms of student performance using measurable objectives. The course includes six…

  5. Fundamentals of Air Conditioning and Refrigeration.

    Science.gov (United States)

    Clemons, Mark

    This set of instructional materials provides secondary and postsecondary students with a state-of-the-art curriculum for the air conditioning and refrigeration industry that includes the many changes brought by new Environmental Protection Agency (EPA) regulations. Introductory materials explain the use of this publication and provide the…

  6. Readings in Air Conditioning and Refrigeration.

    Science.gov (United States)

    Uberto, Jeffrey A.

    Designed to encourage vocational high school students to read by offering reading materials relevant to their vocational goals, this document contains thirty-seven articles related to air conditioning and refrigeration which have been selected from trade journals, magazines, and newspapers and adapted to the students' reading capabilities. A…

  7. Air Conditioning and Refrigeration. Book One.

    Science.gov (United States)

    Wantiez, Gary W.

    Designed to provide students with the basic skills for an occupation in air conditioning and refrigeration, this curriculum guide includes seven major areas, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Orientation (history and development, and job opportunities), Safety…

  8. Space Nuclear Thermal Propulsion (SNTP) Air Force facility

    Science.gov (United States)

    Beck, David F.

    1993-01-01

    The Space Nuclear Thermal Propulsion (SNTP) Program is an initiative within the US Air Force to acquire and validate advanced technologies that could be used to sustain superior capabilities in the area or space nuclear propulsion. The SNTP Program has a specific objective of demonstrating the feasibility of the particle bed reactor (PBR) concept. The term PIPET refers to a project within the SNTP Program responsible for the design, development, construction, and operation of a test reactor facility, including all support systems, that is intended to resolve program technology issues and test goals. A nuclear test facility has been designed that meets SNTP Facility requirements. The design approach taken to meet SNTP requirements has resulted in a nuclear test facility that should encompass a wide range of nuclear thermal propulsion (NTP) test requirements that may be generated within other programs. The SNTP PIPET project is actively working with DOE and NASA to assess this possibility.

  9. Smart sensors enable smart air conditioning control.

    Science.gov (United States)

    Cheng, Chin-Chi; Lee, Dasheng

    2014-06-24

    In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants' information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans' intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be controlled accurately with errors of less than ±0.1 °C. Rapid cool down can be achieved within 2 min to the optimized indoor capacity after occupants enter a room. It's also noted that within two-hour operation the total compressor output of the smart air conditioner is 48.4% less than that of the one using On-Off control. The smart air conditioner with wearable devices could detect the human temperature and activity during sleep to determine the sleeping state and adjusting the sleeping function flexibly. The sleeping function optimized by the smart air conditioner with wearable devices could reduce the energy consumption up to 46.9% and keep the human health. The presented smart air conditioner could provide a comfortable environment and achieve the goals of energy conservation and environmental protection.

  10. Evaporative Condensers in Comfortable Air Conditioning System

    Institute of Scientific and Technical Information of China (English)

    YIN Ying-de; ZHU Dong-sheng; DU Gui-mei; LI Yuan-xi; SUN He-jing; LIU Qing-ming

    2009-01-01

    The operating theory of an evaporative condenser was expatiated.The difference between an e-vaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative con-densers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative con-densing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected.

  11. Air Conditioning System using Rankine Cycle

    Science.gov (United States)

    Nagatomo, Shigemi; Yamaguchi, Hiroichi; Hattori, Hitoshi; Futamura, Motonori

    Natural gas is used as the energy source to cope with the recent situation of increasing demand for electricity especially in summer. In this paper, the performance of a Rankine cycle air conditioning system driven by natural gas was studied. The following results were obtained : (1) Basic equations of performance, refrigerant mass flow rate and expander volume were developed by using the values of heating efficiency, regeneration efficiency, expander efficiency and compressor efficiency. (2) R134a refrigerant has been considered to be suitable for the Rankine cycle air conditioning system, compared with other refrigerants. (3)A Rankine cycle cooling system using R134a refrigerant as a single working fluid was developed. System COP of 0.47 was attained at typical operating condition.

  12. Numerical simulation and nasal air-conditioning

    Directory of Open Access Journals (Sweden)

    Keck, Tilman

    2010-01-01

    Full Text Available Heating and humidification of the respiratory air are the main functions of the nasal airways in addition to cleansing and olfaction. Optimal nasal air conditioning is mandatory for an ideal pulmonary gas exchange in order to avoid desiccation and adhesion of the alveolar capillary bed. The complex three-dimensional anatomical structure of the nose makes it impossible to perform detailed in vivo studies on intranasal heating and humidification within the entire nasal airways applying various technical set-ups. The main problem of in vivo temperature and humidity measurements is a poor spatial and time resolution. Therefore, in vivo measurements are feasible only to a restricted extent, solely providing single temperature values as the complete nose is not entirely accessible. Therefore, data on the overall performance of the nose are only based on one single measurement within each nasal segment. In vivo measurements within the entire nose are not feasible. These serious technical issues concerning in vivo measurements led to a large number of numerical simulation projects in the last few years providing novel information about the complex functions of the nasal airways. In general, numerical simulations merely calculate predictions in a computational model, e.g. a realistic nose model, depending on the setting of the boundary conditions. Therefore, numerical simulations achieve only approximations of a possible real situation. The aim of this review is the synopsis of the technical expertise on the field of in vivo nasal air conditioning, the novel information of numerical simulations and the current state of knowledge on the influence of nasal and sinus surgery on nasal air conditioning.

  13. Innovative Air Conditioning and Climate Control

    Science.gov (United States)

    Graf, John

    2015-01-01

    NASA needed to develop a desiccant wheel based humidity removal system to enable the long term testing of the Orion CO2 scrubber on the International Space Station. In the course of developing that system, we learned three things that are relevant to energy efficient air conditioning of office towers. NASA developed a conceptual design for a humidity removal system for an office tower environment. We are looking for interested partners to prototype and field test this concept.

  14. Low Energy Air Conditioning for Hot Climates

    OpenAIRE

    Almutairi, Hamad Hhn

    2012-01-01

    Fossil fuels are the major sources of electrical power generation in the world. Among all fossil fuels, oil is considered as the most sought-after fuel. The burden on countries that provide subsidized electricity produced from oil-fired power plants is noteworthy. Kuwait is a notable example of these countries. Electricity in Kuwait is heavily consumed by residential air conditioning, which comprises 60% of the total electricity generated at peak times on a hot summer day. From this perspecti...

  15. Investigation of air cleaning system response to accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Andrae, R.W.; Bolstad, J.W.; Foster, R.D.; Gregory, W.S.; Horak, H.L.; Idar, E.S.; Martin, R.A.; Ricketts, C.I.; Smith, P.R.; Tang, P.K.

    1980-01-01

    Air cleaning system response to the stress of accident conditions are being investigated. A program overview and hghlight recent results of our investigation are presented. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. The test facilities used to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components are described. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported.

  16. Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.

    2013-02-01

    This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

  17. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Science.gov (United States)

    Snegirjovs, A.; Shipkovs, P.; Lebedeva, K.; Kashkarova, G.; Migla, L.; Gantenbein, P.; Omlin, L.

    2016-12-01

    Information on the electrical-driven solar air conditioning (SAC) is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC) systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average) systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW). In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  18. Performance Evaluation of Photovoltaic Solar Air Conditioning

    Directory of Open Access Journals (Sweden)

    Snegirjovs A.

    2016-12-01

    Full Text Available Information on the electrical-driven solar air conditioning (SAC is rather scanty. A considerable body of technical data mostly concerns large-scale photo-voltaic solar air conditioning (PV-SAC systems. Reliable information about the energy output has arisen only in recent years; however, it is still not easily accessible, and sometimes its sources are closed. Despite these facts, solar energy researchers, observers and designers devote special attention to this type of SAC systems. In this study, performance evaluation is performed for the PV-SAC technology, in which low-power (up to 15 kWp of cooling power on average systems are used. Such a system contains a PV electric-driven compression chiller with cold and heat sensible thermal storage capacities, and a rejected energy unit used for preheating domestic hot water (DHW. In a non-cooling season, it is possible to partly employ the system in the reverse mode for DHW production. In this mode, the ambient air serves as a heat source. Besides, free cooling is integrated in the PV-SAC concept.

  19. Industrial air conditioning dossier; Dossier Clim industrielle

    Energy Technology Data Exchange (ETDEWEB)

    Nicolas, J.

    2004-04-01

    Because each industrial process is different and has its own specificities, the question of air conditioning in the industry must be considered in a global way and has to take into consideration the different steps of the process and the expectations of prime contractors which, today, pay more attention to the environmental and energy saving aspects. The cooling towers, even if much debated today, remain one of the most efficient solution for high power installations. This dossier presents three examples of realizations: a newspaper printing workshop which requires a precise regulation of temperature and hygrometry, the huge volume workshop of an aerospace company with important solar and internal heat loads, and the painting workshop of a car making company which requires a rigorous control of temperature, humidity and dust content of the ambient air. (J.S.)

  20. Air Motion and Thermal Environment in Pig Housing Facilities with Diffuse Inlet

    DEFF Research Database (Denmark)

    Jacobsen, Lis

    A ventilation system with ambient air supply through diffuse ceiling used in pig production facilities is presented. The climatic conditions were examined both experimentally and numerically in an full scale experimental room and the inlet boundary conditions of the diffuse inlet were examined...... of thermal comfort in terms of the operative temperature of the occupational zone. A model of the boundary condition of the diffuse inlet is necessary because the inlet is a conglomeration of an inlet and a wall boundary condition. Two methods of modelling can be chosen, a model based on the determination...

  1. Automatic air flow control in air conditioning ducts

    Science.gov (United States)

    Obler, H. D.

    1972-01-01

    Device is designed which automatically selects air flow coming from either of two directions and which can be adjusted to desired air volume on either side. Device uses one movable and two fixed scoops which control air flow and air volume.

  2. Indoor air quality assessment of daycare facilities with carbon dioxide, temperature, and humidity as indicators.

    Science.gov (United States)

    Ferng, Shiaw-Fen; Lee, Li-Wen

    2002-11-01

    Poor indoor air quality (IAQ) in daycare facilities affects both attending children and care providers. Incident rates of upper-respiratory-tract infections have been reported to be higher in children who attend daycare. Excessive carbon dioxide (CO2) exposure can cause several health effects and even sudden infant death. For this study, 26 facilities were randomly selected in a Midwestern county of the United States. CO2, room temperature, and relative humidity were used as indicators for IAQ and comfort levels. These IAQ parameters were continuously monitored for eight hours at each facility by a direct-reading instrument that was calibrated before each measurement. More than 50 percent of the facilities had an average CO2 level over the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) standard of 1,000 parts per million (ppm). For temperature and relative humidity, respectively, 42.3 percent and 15.4 percent of facilities were outside of the ASHRAE-recommended comfort zones. The nap-time average CO2 level was about 117 ppm higher than the non-nap-time level. The increment of the nap-time CO2 level in the sleeping-only room over the level in multipurpose rooms was statistically significant (p standard for daycare facilities be established and that children should not be placed in a completely isolated room during nap time.

  3. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong.

    Science.gov (United States)

    Guo, H; Lee, S C; Chan, L Y

    2004-05-05

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM(10) (particulate matters with aerodynamic diameter less than 10 microm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM(10), TBC, CO and NO(2) at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM(10) and TBC. The elevated PM(10) concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM(10) concentration at poultry stalls was higher than the HKIAQO standard of 180 microg/m(3), and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m(3), which was above the HKIAQO standard of 1000 CFU/m(3). The bacteria levels at other three stalls were all below the

  4. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  5. Refrigeration, Heating & Air Conditioning. Post Secondary Curriculum Guide.

    Science.gov (United States)

    Garrison, Joe C.; And Others

    This curriculum guide was designed for use in postsecondary refrigeration, heating and air conditioning education programs in Georgia. Its purpose is to provide for the development of entry level skills in refrigeration, heating, and air conditioning in the areas of air conditioning knowledge, theoretical structure, tool usage, diagnostic ability,…

  6. Activation of air and concrete in medical isotope production facilities

    Science.gov (United States)

    Dodd, Adam C.; Shackelton, R. J.; Carr, D. A.; Ismail, A.

    2017-05-01

    Medical isotope facilities operating in the 10 to 25 MeV proton energy range have long been used to generate radioisotopes for medical diagnostic imaging. In the last few years the beam currents available in commercially available cyclotrons have increased dramatically, and so the activation of the materials within cyclotron vaults may now pose more serious radiological hazards. This will impact the regulatory oversight of cyclotron operations, cyclotron servicing and future decommissioning activities. Air activation could pose a hazard to cyclotron staff. With the increased cyclotron beam currents it was necessary to examine the issue more carefully. Therefore the ways in which radioactivity may be induced in air by neutron reactions and neutron captures were considered and it was found that the dominant mechanism is neutron capture on Ar-40. A study of the activation of the air by neutron capture on Ar-40 within a cyclotron vault was performed using the MCNP Monte Carlo code. The neutron source energy spectrum used was from the production of the widely used F-18 PET isotope. The results showed that the activation of the air within a cyclotron vault does not pose a significant radiological hazard at the beam intensities currently in use and shows how ventilation affects the results. A second MCNP study on the activation of ordinary concrete in cyclotron vaults by neutron capture was made with a view to determining the optimum thickness of borated polyethylene to reduce neutron activation on both the inner surfaces of the vault and around production targets. This is of importance in decommissioning cyclotrons and therefore in the design of new cyclotron vaults. The distribution of activation on the walls as a function of the source position was also studied. Results are presented for both borated and regular polyethylene, and F-18 and Tc-99 neutron spectra.

  7. Microbial Condition of Water Samples from Foreign Fuel Storage Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Berry, C.J. [Westinghouse Savannah River Company, AIKEN, SC (United States); Fliermans, C.B.; Santo Domingo, J.

    1997-10-30

    In order to assess the microbial condition of foreign nuclear fuel storage facilities, fourteen different water samples were received from facilities outside the United States that have sent spent nuclear fuel to SRS for wet storage. Each water sample was analyzed for microbial content and activity as determined by total bacteria, viable aerobic bacteria, viable anaerobic bacteria, viable sulfate- reducing bacteria, viable acid-producing bacteria and enzyme diversity. The results for each water sample were then compared to other foreign samples and to data from the receiving basin for off- site fuel (RBOF) at SRS.

  8. On the history of air conditioning; Zur Geschichte der Raumklimatechnik

    Energy Technology Data Exchange (ETDEWEB)

    Fitzner, Klaus; Finke, Ulrich [Klimakonzept Ingenieurgesellschaft, Berlin (Germany)

    2010-01-15

    The theoretical bases of indoor air conditioning originates from the time of enlightenment (Lavoisier 1792). For the first time air conditioning is applied 1836 in the House of Commons in London. Wide application begins in the USA in the 1930s, in Germany due to the war after the 1950s. Starting from 1970 there are advancements in Germany and Northern Europe, which make it possible not to only air-condition but to fulfil thermally comfortable conditions. (orig.)

  9. PROSPECTS FOR THE DEVELOPMENT OF TECHNOLOGY AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    O. V. Chernyshova

    2008-03-01

    Full Text Available In the article the evaporation cooling and spray (aqueous and air-to-water types of the air-conditioning systems are considered, their merits and demerits are analyzed; the new scheme of a conditioner is offered.

  10. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  11. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  12. EPA Facility Registry Service (FRS): AIRS_AFS_MAJOR

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  13. EPA Facility Registry Service (FRS): AIRS_AQS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  14. EPA Facility Registry Service (FRS): AIRS_AFS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web feature service contains location and facility identification information from EPA's Facility Registry Service (FRS) for the subset of facilities that link...

  15. The air-conditioning capacity of the human nose.

    Science.gov (United States)

    Naftali, Sara; Rosenfeld, Moshe; Wolf, Michael; Elad, David

    2005-04-01

    The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the water fluxes required to condition the ambient inspired air to near alveolar conditions in a variety of environmental conditions and independent of variations in internal structural components. The anatomical replica of the human nose showed the best performance and was able to provide 92% of the heating and 96% of the moisture needed to condition the inspired air to alveolar conditions. A detailed analysis explored the relative contribution of endonasal structural components to the air-conditioning process. During a moderate breathing effort, about 11% reduction in the efficacy of nasal air-conditioning capacity was observed.

  16. Instructional Guide for Air Conditioning and Refrigeration. V & TECC Curriculum Guide.

    Science.gov (United States)

    Duenk, Lester G.; And Others

    This trade and industrial curriculum guide is intended for use in vocational programs that prepare students to enter the air conditioning/refrigeration field. The introductory section provides a statement of philosophy, objectives, block time schedule, and recommended facilities and equipment. Following the introductory section, eighteen blocks of…

  17. Instructional Guide for Air Conditioning and Refrigeration. V & TECC Curriculum Guide.

    Science.gov (United States)

    Duenk, Lester G.; And Others

    This trade and industrial curriculum guide is intended for use in vocational programs that prepare students to enter the air conditioning/refrigeration field. The introductory section provides a statement of philosophy, objectives, block time schedule, and recommended facilities and equipment. Following the introductory section, eighteen blocks of…

  18. Prizes awarded in fiscal 1999 by the Minister for International Trade and Industry on factories having applied excellent energy management. Energy conservation by installing fuel cell power generation facilities utilizing methane gas generated from waste water treatment plants / Improvements toward a clean room and energy saving air conditioning system; 1999 nendo energy kanri yuryo kojo tsusho sangyo daijin hyosho jusho. 1999 nendo shigen energy sho chokan hyosho jusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-04-01

    In order to achieve energy conservation in a waste water treatment plant in a brewery factories, an anaerobic treatment facility was introduced, and a fuel cell power generation facility effectively utilizing methane gas generated from the anaerobic waste water treatment plant was installed. This has resulted in large reduction in the operating number of blowers in the waste water treatment facility of activated sludge system. In addition, electric power, steam, and hot water generated from the fuel cells are effectively utilized as the factory utility. In energy conservation in an optical communication device manufacturing factory, the fan filter unit system was adopted, having been changed from the circulation air conditioner, a conventional type air conditioning system. The present system is a circulation system integrating the fan with the filter, making it possible to circulate air in the room to perform control of temperature, humidity, and dust in a clean room. Thus, the system has eliminated the circulating air conditioner, and reduced the air conditioner capacity by 42% and power consumption by 58.6% compared with those in the conventional circulation system. (NEDO)

  19. Transpired Solar Collector at NREL's Waste Handling Facility Uses Solar Energy to Heat Ventilation Air (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2010-09-01

    The transpired solar collector was installed on NREL's Waste handling Facility (WHF) in 1990 to preheat ventilation air. The electrically heated WHF was an ideal candidate for the this technology - requiring a ventilation rate of 3,000 cubic feet per meter to maintain safe indoor conditions.

  20. Fuel Conditioning Facility Electrorefiner Model Predictions versus Measurements

    Energy Technology Data Exchange (ETDEWEB)

    D Vaden

    2007-10-01

    Electrometallurgical treatment of spent nuclear fuel is performed in the Fuel Conditioning Facility (FCF) at the Idaho National Laboratory (INL) by electrochemically separating uranium from the fission products and structural materials in a vessel called an electrorefiner (ER). To continue processing without waiting for sample analyses to assess process conditions, an ER process model predicts the composition of the ER inventory and effluent streams via multicomponent, multi-phase chemical equilibrium for chemical reactions and a numerical solution to differential equations for electro-chemical transport. The results of the process model were compared to the electrorefiner measured data.

  1. Sufficient conditions for optimal facility locations to coincide

    DEFF Research Database (Denmark)

    Juel, Henrik; Love, Robert F.

    1980-01-01

    In some cases multifacility location problems may be solved by verifying a few simple inequalities involving the interfacility weights. The authors develop certain inequalities which are sufficient conditions for optimality in some multifacility problems. In the problems considered, distances are...... are represented by a symmetric metric and there are no constraints on the location of the new facilities......In some cases multifacility location problems may be solved by verifying a few simple inequalities involving the interfacility weights. The authors develop certain inequalities which are sufficient conditions for optimality in some multifacility problems. In the problems considered, distances...

  2. The effect of air-conditioning parameters and deposition dust on microbial growth in supply air ducts

    Energy Technology Data Exchange (ETDEWEB)

    Li, Angui; Liu, Zhijian; Zhu, Xiaobin; Liu, Ying [School of Environmental and Municipal Engineering, Xi' an University of Architecture and Technology, Xi' an, Shannxi 710055 (China); Wang, Qingqin [China Academy of Building Research, Beijing 100013 (China)

    2010-04-15

    To investigate the effect of air-conditioning parameters (including temperature, relative humidity and air velocity) and deposition dust on microbial growth in supply air duct, a complete test facility according to ASHRAE Standard 62.1-2007 was constructed. A series of experiments for testing microbial concentration (including bacteria and fungus) were conducted under different working conditions (such as different temperatures and relative humidity). The air velocity was constantly kept at 2.0 m/s. Orthogonal design was employed for the analysis of test data. The results indicated that air velocity attenuation down the direction of the supply air affected dust distribution at the bottom of duct, to some extent, and the number of microorganisms was positively correlated with the quantity of dust. In the range of temperature 22-32 C and relative humidity (RH) 40-90%, microbial growth significantly accelerated with higher temperature and RH increasing. The organic compounds composing the dust also had great impact on microbial growth. The basic researches are contributed to control the growth of microorganism and improve the indoor microenvironment in the air-conditioning room. (author)

  3. Possible Economies in Air-Conditioning by Accepting Temperature Swings.

    Science.gov (United States)

    Loudon, A. G.; Petherbridge, P.

    Public building air conditioning systems, which use constant and varying heat and cooling loads, are compared and investigated. Experiments indicated that constant temperature controls based on outside air temperature alone were inefficient. Ventilating a building with outside air and the methods of doing so are cited as being the most economical…

  4. Vibration Analysis of Air Condition Unit on Subway

    Directory of Open Access Journals (Sweden)

    Yan Liu

    2013-06-01

    Full Text Available Subway system has many merits including large passenger carrying ability, high speed, strong controllability and reliability of driving. Nevertheless, subways also have brought many disadvantages for human. In many subway systems, noisy environments are clearly observed and passengers are exposed to higher noise levels than permissible limit. This study presents a study of noise and vibration of subway air condition system, so as to grasp the vibration distribution laws of the air condition system. By the tested of noise and vibration, the researcher find the sound distribution rule of air condition is very important Based on the consequence of the testing, the acceleration of air condition has little to do with the subway speed and more to do with the vibration of fan; When the train driving on the viaduct bridge, the acceleration of air condition is biggish in 125 Hz and In 50-1000 Hz the vibration of air condition is obviously. When the train running underground line, as a result of the resonance of body, air condition’s vibration is biggish in 630 Hz and the vibration is obviously in 125-1250 Hz. With the increase of the speed, the influence of the ground’s second radiation on body vibration is enhanced. The superfine gross wool which is used to air condition can achieve good results for noise reduction. This research has higher reference for the vibration and noise reduction of the subway air condition system.

  5. CFD simulation of air discharge tests in the PPOOLEX facility

    Energy Technology Data Exchange (ETDEWEB)

    Tanskanen, V.; Puustinen, M. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2008-07-15

    This report summarizes the CFD simulation results of two air discharge tests of the characterizing test program in 2007 with the scaled down PPOOLEX facility. Air was blown to the dry well compartment and from there through a DN200 blowdown pipe into the condensation pool (wet well). The selected tests were modeled with Fluent CFD code. Test CHAR-09-1 was simulated to 28.92 seconds of real time and test CHAR-09-3 to 17.01 seconds. The VOF model was used as a multiphase model and the standard k epsilon-model as a turbulence model. Occasional convergence problems, usually at the beginning of bubble formation, required the use of relatively short time stepping. The simulation time costs threatened to become unbearable since weeks or months of wall-clock time with 1-2 processors were needed. Therefore, the simulated time periods were limited from the real duration of the experiments. The results obtained from the CFD simulations are in a relatively good agreement with the experimental results. Simulated pressures correspond well to the measured ones and, in addition, fluctuations due to bubble formations and breakups are also captured. Most of the differences in temperature values and in their behavior seem to depend on the locations of the measurements. In the vicinity of regions occupied by water in the experiments, thermocouples getting wet and drying slowly may have had an effect on the measured temperature values. Generally speaking, most temperatures were simulated satisfyingly and the largest discrepancies could be explained by wetted thermocouples. However, differences in the dry well and blowdown pipe top measurements could not be explained by thermocouples getting wet. Heat losses and dry well / wet well heat transfer due to conduction have neither been estimated in the experiments nor modeled in the simulations. Estimation of heat conduction and heat losses should be carried out in future experiments and they should be modeled in future simulations, too. (au)

  6. Air conditioning and blowers. Special issue; Airconditioning en ventilatoren. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Nekeman, H.E. [Multi Import, Rotterdam (Netherlands); Hol, M. [Aircool Klimaattechniek, Ridderkerk (Netherlands); Bassa, E. [ed.

    1997-06-01

    In four articles several aspects of air conditioners and blowers are discussed: the application of the newly developed electronically commutated direct current engine in high-efficiency boilers, air conditioners and cooling systems, the future for flexible synthetic cooling pipes, a description of a Mitsubishi-developed air conditioner: the Inverter Driven Multi-indoor unit, also known as the KX-system, and the importance of the private sector (houses, small businesses, cars) for the use of air conditioning installations. 8 figs.

  7. 75 FR 18255 - Passenger Facility Charge Database System for Air Carrier Reporting

    Science.gov (United States)

    2010-04-09

    ... Federal Aviation Administration Passenger Facility Charge Database System for Air Carrier Reporting AGENCY... interested parties of the availability of the Passenger Facility Charge (PFC) database system to report PFC..., 2010. FOR FURTHER INFORMATION CONTACT: Jane Johnson, Financial Analysis and Passenger Facility Charge...

  8. Heating, Ventilation and Air-Conditioning Systems, Part of Indoor Air Quality Design Tools for Schools

    Science.gov (United States)

    The main purposes of a Heating, Ventilation, and Air-Conditioning system are to help maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort. HVAC systems are among the largest energy consumers in schools.

  9. Section 609 of the Clean Air Act: Motor Vehicle Air Conditioning

    Science.gov (United States)

    Fact sheet provides a general overview of EPA regulations under Section 609 of the Clean Air Act, which is focused on preventing the release of refrigerants during the servicing of motor vehicle air-conditioning systems and similar appliances.

  10. Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act_considered MAJOR permits

    Data.gov (United States)

    Iowa State University GIS Support and Research FacilityAir emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act, considered "major" permits. Also includes emission points...

  11. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  12. Energy Efficiency for Heating, Ventilating, Air-Conditioning Instructors.

    Science.gov (United States)

    Scharmann, Larry, Ed.; Lay, Gary, Ed.

    Intended primarily but not solely for use at the postsecondary level, this curriculum guide contains five units on energy efficiency that were designed to be incorporated into an existing program in heating, ventilating, and air-conditioning. The following topics are examined: how energy conservation pays, heating, ventilation, air-conditioning,…

  13. Thermal Environment for Classrooms. Central System Approach to Air Conditioning.

    Science.gov (United States)

    Triechler, Walter W.

    This speech compares the air conditioning requirements of high-rise office buildings with those of large centralized school complexes. A description of one particular air conditioning system provides information about the system's arrangement, functions, performance efficiency, and cost effectiveness. (MLF)

  14. Application of solar energy to air-conditioning

    Science.gov (United States)

    Harstad, A. J.; Nash, J. M.

    1978-01-01

    Results of survey of application of solar energy to air-conditioning systems are summarized in report. Survey reviewed air-conditioning techniques that are most likely to find residential applications and that are compatible with solar-energy systems being developed.

  15. Thermal Environment for Classrooms. Central System Approach to Air Conditioning.

    Science.gov (United States)

    Triechler, Walter W.

    This speech compares the air conditioning requirements of high-rise office buildings with those of large centralized school complexes. A description of one particular air conditioning system provides information about the system's arrangement, functions, performance efficiency, and cost effectiveness. (MLF)

  16. Energy Efficiency for Heating, Ventilating, Air-Conditioning Instructors.

    Science.gov (United States)

    Scharmann, Larry, Ed.; Lay, Gary, Ed.

    Intended primarily but not solely for use at the postsecondary level, this curriculum guide contains five units on energy efficiency that were designed to be incorporated into an existing program in heating, ventilating, and air-conditioning. The following topics are examined: how energy conservation pays, heating, ventilation, air-conditioning,…

  17. Air Conditioning and Refrigeration Program Articulation, 1981-1982.

    Science.gov (United States)

    Dallas County Community Coll. District, TX.

    Based on a survey of high school programs and courses in the Dallas County Community College District (DCCCD), this articulated program is designed to prepare students for entry-level employment in the air conditioning and refrigeration industry, including residential and commercial air conditioning and commercial refrigeration. The skills and…

  18. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    OpenAIRE

    Daniela Pinheiro da Silva

    2014-01-01

    Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acqui...

  19. Solar-powered air-conditioning

    Science.gov (United States)

    Clark, D. C.; Rousseau, J.

    1977-01-01

    Report focuses on recent study on development of solar-powered residential air conditioners and is based on selected literature through 1975. Its purposes are to characterize thermal and mechanical systems that might be useful in development of Rankine-cycle approach to solar cooling and assessment of a Lithium Bromide/Water absorption cycle system.

  20. Design of demonstration facility for advanced spent fuel conditioning process

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, W. M.; Koo, J. H.; Jeo, I. J.; Kook, D. H.; Lee, E. P.; Baek, S. R.; Lee, K. I.; You, K. S.; Park, S. W. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    The Advanced spent fuel Conditioning Process(ACP) was proposed and developed for effective management of the PWR spent fuel. The detail plan was established for demonstration and verification of the ACP, and an existing hot cell will be modified as {alpha}-{gamma} type hot cell. In this study, the process mechanical flow was analysed for the optimum arrangement to ensure effective process operation in hot cell, and the detail design of hot cell including the auxiliary facility and safety analysis was performed to secure conservative safety of hot cell system. And then, this results will be utilized for hot cell refurbishment and license.

  1. Testing hot cell shielding in the fuel conditioning facility.

    Science.gov (United States)

    Courtney, J C; Klann, R T

    1997-01-01

    A comprehensive shield test program for a hot cell complex, the Fuel Conditioning Facility at Argonne National Laboratory, has been completed with minimum radiation exposure to participants. The recently modified shielding design for two hot cells and their associated transfer paths for irradiated materials was analyzed and tested for attenuating gamma rays from mixed fission product sources. Testing was accomplished using 0.37 TBq (10 Ci) and 518 TBq (14,000 Ci) 60Co sources. Of specific concern were radiation levels around wall penetrations and the interface between transport casks and the cell floor. Detailed measurements were made for surfaces that bound the hot cells, a transfer tunnel between the two cells, and storage pits that extend below the floors of both cells. In addition to surface measurements, dose equivalent rates in adjacent corridors were determined when the larger source was exposed. Results indicate that with some administrative controls, the facility shields are adequate to meet the design criterion that limits annual dose to less than 10 mSv (1 rem) for facility workers.

  2. Energy consumption in air-conditioning; Improvement and Reduction

    Directory of Open Access Journals (Sweden)

    Yacoub Yousef Ahmad Alotaibi

    2015-06-01

    Full Text Available Anew technique to reduce latent heat to improve energy consumption in air-conditioning is by using Desiccant . The aim of dehumidification process is to remove the water vapor from the processed air to liquid desiccants. Dehumidification is considered as a key feature of HVAC systems for thermal comfort. Chemical dehumidification is remove the water vapour from the air by transferring it towards a desiccant material (adsorption or absorption. Results illustrate that the application of liquid desiccant in air conditioning can improve indoor air quality, reduce energy consumption and bring environmentally friendly products, also. Lewis number increased rapidly with the increase of solution concentration Therefore liquid desiccant air conditioning systems are drawing more and more attention in recent years.

  3. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  4. Low energy air conditioning of shelters for telecommunication networks

    Energy Technology Data Exchange (ETDEWEB)

    Romagnoni, P. [Ist. Univ. di Architettura, Venezia (Italy); Scattolin, M. [Liebert Hiross, Piove di Sacco (PD) (Italy); Zecchin, R. [Dipt. di Fisica Tecnica, Padova (Italy)

    2000-07-01

    The control of the air temperature in a shelter for telecommunication networks is an important task for the correct operation of its electronic equipment. Different technical solutions have been studied in order to improve the energy performances of air conditioning plants: for this purpose direct free cooling allows to reduce the energy consumption to maintain the internal air temperature below the prescribed values. Nowadays the internal air temperature may rise up to 60 C, due to the high technology of the electronic equipment, and new solutions for the air temperature control can be proposed. This paper analyses the dynamic thermal performances of a shelter used in telecommunication networks, fitted up with an ''air - to air'' plate heat exchanger without mixing between internal and external air flows. Useful information, concerning the thermal and energy performances of this system is given for design purposes. (orig.)

  5. Does air conditioning impact on hygienic quality of indoor air on seagoing vessels?

    Science.gov (United States)

    Meyer, Gabriele; Schepers, Bernd-Fred

    2007-01-01

    According to observations by occupational health physicians, nearly 50 % of the seamen on German vessels will get diseases of the upper respiratory tract. An impact of the air-conditioning systems on these diseases has been suggested. To examine the hygienic quality of indoor air on seagoing vessels, a pilot study was initiated by the See-Berufsgenossenschaft. Air samples were taken on-site at different sampling sites and analysed for the occurrence of microorganisms. Bacteria showed the highest cell numbers and the highest distribution in indoor air on vessels, whereby the maximum level was determined in the air of crew cabins. The identification of bacteria showed that beside common airborne species, pathogens existed. Air-conditioning seems to influence the quality of indoor air on seagoing vessels. Interim results of the study indicate that regular maintenance of air-conditioning systems is essential.

  6. Air-conditioning in the human nasal cavity.

    Science.gov (United States)

    Elad, David; Wolf, Michael; Keck, Tilman

    2008-11-30

    Healthy humans normally breathe through their nose even though its complex geometry imposes a significantly higher resistance in comparison with mouth breathing. The major functional roles of nasal breathing are defense against infiltrating particles and conditioning of the inspired air to nearly alveolar conditions in order to maintain the internal milieu of the lung. The state-of-the-art of the existing knowledge on nasal air-conditioning will be discussed in this review, including in vivo measurements in humans and computational studies on nasal air-conditioning capacity. Areas where further studies will improve our understanding and may help medical diagnosis and intervention in pathological states will be introduced.

  7. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  8. Air Conditioning Systems from a 2nd Law Perspective

    Directory of Open Access Journals (Sweden)

    Luigi Marletta

    2010-04-01

    Full Text Available In this paper exergy analysis is used to assess the performance of the three most common air conditioning plant schemes: all-air, dual-duct and fan-coil systems. The results are presented in terms of flow diagrams to provide a clear picture of the exergy flow across the systems. The most relevant outcomes are that the air cooling and dehumidification is the process most responsible for the exergy loss and that the exergy efficiency of the overall systems is rather low; thus the quest for more appropriate technologies. Solar-assisted air-conditioning is also discussed, outlining the possibilities and the constraints.

  9. [Assessment of the air quality improment of cleaning and disinfection on central air-conditioning ventilation system].

    Science.gov (United States)

    Liu, Hongliang; Zhang, Lei; Feng, Lihong; Wang, Fei; Xue, Zhiming

    2009-09-01

    To assess the effect of air quality of cleaning and disinfection on central air-conditioning ventilation systems. 102 air-conditioning ventilation systems in 46 public facilities were sampled and investigated based on Hygienic assessment criterion of cleaning and disinfection of public central air-conditioning systems. Median dust volume decreased from 41.8 g/m2 to 0.4 g/m2, and the percentage of pipes meeting the national standard for dust decreased from 17.3% (13/60) to 100% (62/62). In the dust, median aerobic bacterial count decreased from 14 cfu/cm2 to 1 cfu/cm2. Median aerobic fungus count decreased from 10 cfu/cm2 to 0 cfu/cm2. The percentage of pipes with bacterial and fungus counts meeting the national standard increased from 92.4% (171/185) and 82.2% (152/185) to 99.4% (165/166) and 100% (166/166), respectively. In the ventilation air, median aerobic bacterial count decreased from 756 cfu/m3 to 229 cfu/m3. Median aerobic fungus count decreased from 382 cfu/m3 to 120 cfu/m3. The percentage of pipes meeting the national standard for ventilation air increased from 33.3% (81/243) and 62.1% (151/243) to 79.8% (292/366) and 87.7% (242/276), respectively. But PM10 rose from 0.060 mg/m3 to 0.068 mg/m3, and the percentage of pipes meeting the national standard for PM10 increased from 74.2% (13/60) to 90.2% (46/51). The cleaning and disinfection of central air-conditioning ventilation systems could have a beneficial effect of air quality.

  10. Experimental tests of a gas fired adsorption air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Poyelle, F.; Guilleminot, J.J.; Meunier, F. [C.N.R.S.-L.I.M.S.I., Orsay Cedex (France); Canal, P.; Soide, I.; Klemsdal, E. [Gaz de Francer Saint Denis La Plaine (France)

    1997-10-01

    Over recent years, there has been growing interest for air conditioning systems, for commercial and offices buildings, transport and residential houses. Gaz de France promote natural gas powered air conditioning systems through the installation of commercial absorption machines, producing chilled and/or hot water. These machines cover loads from 70 kW to 5 MW. Gaz de France`s purpose is to develop a small scale natural gas fueled air conditioning system for residential applications and small commercials (5-20 kW). In order to study the feasibility of a small scale adsorption machine, a prototype has been studied, designed, constructed and tested. (au) 11 refs.

  11. Simulation technology for refrigeration and air conditioning appliances

    Institute of Scientific and Technical Information of China (English)

    DING Guoliang

    2006-01-01

    Simulation technology has been widely used for performance prediction and optimal design of refrigeration and air conditioning appliances. A brief history of simulation technology for refrigeration and air conditioning appliances is reviewed. The models for evaporator, condenser, compressor, capillary tube and thermal insulation layer are summarized, and a fast calculation method for thermodynamic properties of refrigerant is introduced in this paper. The model-based intelligent simulation technology and the simulation technology based on graph theory are also illustrated. Finally, an updated trend of simulation technology development for refrigeration and air conditioning appliances is discussed.

  12. Desiccant Enhanced Evaporative Air Conditioning: Parametric Analysis and Design; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Woods, J.; Kozubal, E.

    2012-10-01

    This paper presents a parametric analysis using a numerical model of a new concept in desiccant and evaporative air conditioning. The concept consists of two stages: a liquid desiccant dehumidifier and a dew-point evaporative cooler. Each stage consists of stacked air channel pairs separated by a plastic sheet. In the first stage, a liquid desiccant film removes moisture from the process (supply-side) air through a membrane. An evaporatively-cooled exhaust airstream on the other side of the plastic sheet cools the desiccant. The second-stage indirect evaporative cooler sensibly cools the dried process air. We analyze the tradeoff between device size and energy efficiency. This tradeoff depends strongly on process air channel thicknesses, the ratio of first-stage to second-stage area, and the second-stage exhaust air flow rate. A sensitivity analysis reiterates the importance of the process air boundary layers and suggests a need for increasing airside heat and mass transfer enhancements.

  13. Performance and evaluation of desiccant based air conditioning system.

    Directory of Open Access Journals (Sweden)

    Gaurav S. Wani

    2014-12-01

    Full Text Available This Project work presents study and experimental analysis of Desiccant based air conditioning system.The main purpose of this project is to increase the efficency of air conditioning system.In the convenstional air conditioning system cooling coli has two load latent load and sensible load. Cooling has to cool the air and simultaneously to dehumidify it.It increases load on cooling coil and affects performance to the system. To increase the efficiency the air conditioning system desiccant materials are used at the inlet of the air conditioning test rig. Desiccant materials attract moisture based on differences in vapor pressure. Due to their enormous affinity to absorb water and considerable ability to hold water. Due to use of desiccant material load on the cooling coil reduces since moisture is absorbed by desiccant; cooling coil has to take only sensible load. Analysis is done using different desiccant materials and based on the observation, power consumption before and after desiccant is calculated. From this conclusion is made that desiccant material improves the efficiency of air conditioning test rig

  14. Army Air and Missile Defense Network Design Facility (AAMDNDF)

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides JTIDS network designs and platform initialization load files for all Joint and Army-only tests, exercises, operations, and contingency events...

  15. Quantifying atmospheric stability conditions at a swine facility and an adjacent corn field in Iowa, USA

    Science.gov (United States)

    Hernandez-Ramirez, Guillermo; Sauer, Thomas J.; Hatfield, Jerry L.; Prueger, John H.

    2011-10-01

    Atmospheric stability conditions in the atmospheric surface layer control the distance and direction of transport of air contaminants. Near confined animal facilities, transport processes significantly impact air quality as these sites typically act as point sources of dust and odor constituents; however, little information is available on atmospheric stability effects. This study was conducted to assess year-round temporal patterns of atmospheric stability at a swine production facility and an adjacent commercial corn field (CF) in the US Midwest. Two towers of 10 and 20 m heights for continuous micrometeorological measurements were deployed within a CF and between swine buildings (BSB), respectively. Each tower was equipped with an eddy-covariance system at 6.8 m height, infrared thermometers, and six cup anemometers with thermocouples installed at log-distributed heights. Overall results from gradient Richardson number and Monin-Obukhov (z/L) calculations revealed a greater prevalence of unstable conditions for BSB compared with CF. During the 13-month measurement period, unstable cases (z/L ranging from -1 to -0.01) occurred 1.4 times more frequently for BSB than CF (52 vs. 39%, respectively), while stable cases (0.011-0.2) were 1.8 times more frequent for CF than BSB (24 vs. 14%, respectively). These patterns were partly associated with higher surface radiometric temperatures for BSB. Relatively greater diurnal heat capture at BSB (ground and roof surfaces) and a cooling effect in CF through active canopy transpiration during the daytime explain these z/L and radiometric temperature results. Prevalent diurnal atmospheric instability at BSB suggests enhanced ascendant vertical transport of air pollutants perhaps causing greater mixing/dilution with the atmospheric layer and/or their facilitated transport over greater distances when sorbed onto particles. This enhanced understanding of the spatio-temporal patterns of atmospheric stability can be subsequently

  16. MARANGONI CONVECTION AROUND A VENTILATED AIR BUBBLE UNDER MICROGRAVITY CONDITIONS

    NARCIS (Netherlands)

    HOEFSLOOT, HCJ; JANSSEN, LPBM; HOOGSTRATEN, HW

    Under microgravity conditions in both parabolic and sounding rocket flights, the mass-transfer-induced Marangoni convection around an air bubble was studied. To prevent the bubble from becoming saturated, the bubble was ventilated. It turned out that the flow rate of the air through the bubble

  17. Measurement of Vehicle Air Conditioning Pull-Down Period

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, John F [ORNL; Huff, Shean P [ORNL; Moore, Larry G [ORNL; West, Brian H [ORNL

    2016-08-01

    Air conditioner usage was characterized for high heat-load summer conditions during short driving trips using a 2009 Ford Explorer and a 2009 Toyota Corolla. Vehicles were parked in the sun with windows closed to allow the cabin to become hot. Experiments were conducted by entering the instrumented vehicles in this heated condition and driving on-road with the windows up and the air conditioning set to maximum cooling, maximum fan speed and the air flow setting to recirculate cabin air rather than pull in outside humid air. The main purpose was to determine the length of time the air conditioner system would remain at or very near maximum cooling power under these severe-duty conditions. Because of the variable and somewhat uncontrolled nature of the experiments, they serve only to show that for short vehicle trips, air conditioning can remain near or at full cooling capacity for 10-minutes or significantly longer and the cabin may be uncomfortably warm during much of this time.

  18. Transitioning to Low-GWP Alternatives in Unitary Air Conditioning

    Science.gov (United States)

    This fact sheet provides current information on low-Global Warming Potential (GWP) refrigerant alternatives used in unitary air-conditioning equipment, relevant to the Montreal Protocol on Substances that Deplete the Ozone Layer.

  19. Persistence of Initial Conditions in Continental Scale Air Quality Simulations

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains the data used in Figures 1 – 6 and Table 2 of the technical note "Persistence of Initial Conditions in Continental Scale Air Quality...

  20. Poor weather conditions and flight operations: Implications for air ...

    African Journals Online (AJOL)

    Poor weather conditions and flight operations: Implications for air transport hazard ... Ethiopian Journal of Environmental Studies and Management ... fog, dust haze and line squall that affect flight operation such as flight delays, diversion and ...

  1. Application of Solar Energy to Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    M, Nash J; J, Harstad A

    1976-11-01

    The results of a survey of solar energy system applications of air conditioning are summarized. Techniques discussed are both solar powered (absorption cycle and the heat engine/ Rankine cycle) and solar related (heat pump). Brief descriptions of the physical implications of various air conditioning techniques, discussions of status, proposed technological improvements, methods of utilization and simulation models are presented, along with an extensive bibliography of related literature.

  2. Application of solar energy to air conditioning systems

    Science.gov (United States)

    Nash, J. M.; Harstad, A. J.

    1976-01-01

    The results of a survey of solar energy system applications of air conditioning are summarized. Techniques discussed are both solar powered (absorption cycle and the heat engine/Rankine cycle) and solar related (heat pump). Brief descriptions of the physical implications of various air conditioning techniques, discussions of status, proposed technological improvements, methods of utilization and simulation models are presented, along with an extensive bibliography of related literature.

  3. Investigation of solar energy utilization in a novel desiccant based air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Hurdodan, Ertac; Buyukalaca, Orhan [Department of Energy Systems Engineering, Faculty of Engineering, Osmaniye Korkut Ata University (Turkey)], email: ehurdogan@osmaniye.edu.tr, email: obuyukalaca@osmaniye.edu.tr; Yilmaz, Tuncay; Uckan, Irfan [Department of Mechanical Engineering, Faculty of Engineering and Architecture, Cukurova University (Turkey)], email: tunyil@cu.edu.tr, email: iuckan@cu.edu.tr; Hepbasli, Arif [Department of Mechanical Engineering, College of Engineering, King Saud University (Saudi Arabia)], email: ahepbasli.c@ksu.edu.sa

    2011-07-01

    Desiccant-based air-conditioning systems are an alternative to traditional air conditioning units. They have superior humidity control and are usually used in health care facilities to reduce the airborne transmission of disease. In the present study, an innovative, desiccant-based air-conditioning system was designed and tested in Cukurova University, Adana, Turkey. A model for investigating the use of solar energy in the system was developed. Experimental temperatures throughout the cooling season of 2008 and solar radiation data, measured by the State Meteorological Affairs (DMI) over the period 1986-2006, were utilized in the model. A comparison was made between the results obtained from the model and those from the experiments and it was concluded that solar energy could be utilized in the system. Solar energy also increased the coefficient of performance (COP) of the system by between 50% and 120% and was shown to be a cost-effective way of regenerating the desiccant.

  4. Extreme conditions in a dissolving air nanobubble

    Science.gov (United States)

    Yasui, Kyuichi; Tuziuti, Toru; Kanematsu, Wataru

    2016-07-01

    Numerical simulations of the dissolution of an air nanobubble in water have been performed taking into account the effect of bubble dynamics (inertia of the surrounding liquid). The presence of stable bulk nanobubbles is not assumed in the present study because the bubble radius inevitably passes the nanoscale in the complete dissolution of a bubble. The bubble surface is assumed to be clean because attachment of hydrophobic materials on the bubble surface could considerably change the gas diffusion rate. The speed of the bubble collapse (the bubble wall speed) increases to about 90 m/s or less. The shape of a bubble is kept nearly spherical because the amplitude of the nonspherical component of the bubble shape is negligible compared to the instantaneous bubble radius. In other words, a bubble never disintegrates into daughter bubbles during the dissolution. At the final moment of the dissolution, the temperature inside a bubble increases to about 3000 K due to the quasiadiabatic compression. The bubble temperature is higher than 1000 K only for the final 19 ps. However, the Knudsen number is more than 0.2 for this moment, and the error associated with the continuum model should be considerable. In the final 2.3 ns, only nitrogen molecules are present inside a bubble as the solubility of nitrogen is the lowest among the gas species. The radical formation inside a bubble is negligible because the probability of nitrogen dissociation is only on the order of 10-15. The pressure inside a bubble, as well as the liquid pressure at the bubble wall, increases to about 5 GPa at the final moment of dissolution. The pressure is higher than 1 GPa for the final 0.7 ns inside a bubble and for the final 0.6 ns in the liquid at the bubble wall. The liquid temperature at the bubble wall increases to about 360 K from 293 K at the final stage of the complete dissolution.

  5. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  6. Sea water air conditioning : a cost effective alternative

    Energy Technology Data Exchange (ETDEWEB)

    Elsafty, A.F. [Arab Academy for Science, Technology and Maritime Transport, Alexandria (Egypt). Dept. of Mechanical Engineering, College of Engineering and Technology; Saeid, L. [National Gas Company, Cairo (Egypt). GIS and Design Section

    2009-07-01

    The 2 main types of air conditioning systems are vapor compression systems which are electrically operated, and absorption systems which are heat operated. This paper presented a new air conditioning technique for use in the Middle East. The Sea Water Air Conditioning (SWAC) system uses deep cold ocean and sea water as a renewable energy source to air-condition buildings. A technical and economical assessment was performed to determine the advantages of the SWAC system over conventional vapor compression systems to air-condition hotels and resorts at a new tourists resort in Egypt. Meteorological data for the region was used to estimate the gross cooling load for the hotels using the HVAC Load Explorer program. The major components of the SWAC system were sized and analyzed to the determine its operational performance and to estimate the probable costs. The economic analysis was based on two different methods, notably the net present value (NPV) and the simple pay back method. Three options were investigated in the economic study. The first was the use of a conventional air conditioning system to provide a baseline for the other options being investigated. The second option was the use of deep sea water only, and the third option involved the use of a hybrid system using both a sea water air conditioning system and a conventional chiller in series. The SWAC system was the preferred option for its minimum net present value as well as the short pay back period. The energy savings approached 80 per cent of conventional air-conditioners. It was concluded that in addition to reducing electricity use, the SWAC systems can contribute to a reduction in greenhouse gases. 11 refs., 7 tabs., 6 figs.

  7. Wind Tunnel Evaluation of Vegetative Buffer Effects on Air Flow near Swine Production Facilities

    Science.gov (United States)

    Increasing concerns about generation and transport of swine odor constituents have substantiated wind tunnel simulation studies on air flow dynamics near swine production facilities. A possible odor mitigation strategy is a forest vegetative buffer as a windbreak barrier near swine facilities becaus...

  8. Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-04-01

    As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

  9. Arc Jet Facility Test Condition Predictions Using the ADSI Code

    Science.gov (United States)

    Palmer, Grant; Prabhu, Dinesh; Terrazas-Salinas, Imelda

    2015-01-01

    The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.

  10. Auditing the European room air-conditioning systems and potential energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Bory, Daniela; Adnot, Jerome; Greco, Carmelo; Marchio, Dominique [Ecole des Mines de Paris, Center for Energy and Processes (France)

    2007-07-01

    Nowadays, the European Community promotes the energy improvement of the air-conditioning (AC) systems through the compulsory inspection of these facilities in the frame of the Energy Performance of Buildings Directive [EPBD, 2002]. Inspection itself is just a motivating mean for the AC actors to improve the energy efficiency of the systems and reduce energy. Therefore, the aim of the inspection is to follow periodically the correct management of the facility through a quick visit of the plant and a study of the available documentation while the aim of the audit is the research of best efficiency improvements which requires further investigations to evaluate and quantify the savings. Audit differs from the common maintenance activities of the facilities, the aim of which is limited to guarantee the basic operation of the plant. There is an overall lack of methodologies specific for air-conditioning and the improvements proposed are seldom proven with scientific rigour. For room air conditioning systems, the impacts of defect during operation due to ageing and neglected maintenance are considered: fouled condenser, charge leaks, compressor performances reduced, fans degradation, filter fouling and additional pressure drop in liquid line are explored. The over consumption due to these defects is evaluated for different building types and French climates. The results allow to define simple methods that can be used by the auditors to estimate the energy savings due to the correction of the defects.

  11. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Directory of Open Access Journals (Sweden)

    Mohamed M. El-Awad

    2011-03-01

    Full Text Available The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  12. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Energy Technology Data Exchange (ETDEWEB)

    El-Awad, Mohamed M. [Mechanical Engineering Department, the University of Khartoum, P.O. Box 321 Khartoum (Sudan)

    2011-07-01

    The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min) air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  13. Prediction of air temperature in the aircraft cabin under different operational conditions

    Directory of Open Access Journals (Sweden)

    Fišer J.

    2013-04-01

    Full Text Available This paper deals with the prediction of the air temperature in the aircraft cabin by means of Computational Fluid Dynamics. The simulations are performed on the CFD model which is based on geometry and cabin interior arrangement of the Flight Test Facility (FTF located at Fraunhofer IBP, Germany. The experimental test flights under three different cabin temperatures were done in FTF and the various data were gathered during these flights. Air temperature in the cabin was measured on probes located near feet, torso and head of each passenger and also surface temperature and air temperature distributed from inlets were measured. The data were firstly analysed in order to obtain boundary conditions for cabin surfaces and inlets. Then the results of air temperature from the simulations were compared with measured data. The suitability and accuracy of the CFD approach for temperature prediction is discussed.

  14. Need for thermal-storage air-conditioning in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Hasnain, Syed Mahmood; Alabbadi, Naif Mohammed [King Abdulaziz City for Science and Technology (KACST), Energy Research Inst., Riyadh (Saudi Arabia)

    2000-04-01

    In Saudi Arabia, the growth of demand for electrical energy in the rapidly expanding towns, cities and industries, far exceeds the growth of the power being made available. Recently the Saudi Consolidated Electric Companies (SCECO) are facing a shortage of electricity during the summer period mainly due to the high consumption of electricity in the air conditioning sector. The incorporation of thermal energy storage (TES) technologies with a conventional air conditioning system is found to be an appropriate solution for energy-demand management. In this paper an introductory overview of thermal storage air conditioning is presented, comparing phase change (e.g. ice) and sensible heat (e.g. chilled water) storage technologies. The pros and cons of each are evaluated. The suitability of TES technology for the Saudi HVAC (heating, ventilating and air conditioning) industry is explored with the benefits to the owner such as: reduced energy consumption; less operation and maintenance costs; and downsizing of the chiller plant and system for new facility; alternative to new chiller installation to cater for increased cooling load; and stored water as a fire protection source. Furthermore, an economic study has been presented to illustrate the feasibility of TES based air conditioning in Saudi Arabia. (Author)

  15. Applicability of sewage heat pump air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    陈金华; 刘猛; 刘勇; 靳鸣; 陈洁

    2009-01-01

    A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.

  16. 33 CFR 6.14-2 - Condition of waterfront facility a danger to vessel.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Condition of waterfront facility a danger to vessel. 6.14-2 Section 6.14-2 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... of Waterfront Facilities and Vessels in Port § 6.14-2 Condition of waterfront facility a danger...

  17. 42 CFR 494.120 - Condition: Special purpose renal dialysis facilities.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Special purpose renal dialysis... RENAL DISEASE FACILITIES Patient Care § 494.120 Condition: Special purpose renal dialysis facilities. A special purpose renal dialysis facility is approved to furnish dialysis on a short-term basis at...

  18. Effects of suspension of air-conditioning on airtight-type racks.

    Science.gov (United States)

    Kanzaki, M; Fujieda, M; Furukawa, T

    2001-10-01

    Although isolation racks are superior to open-type racks in terms of securing breeding conditions for laboratory animals, the contingency-proofing capability of the former has yet to be determined. Therefore, from the view of risk management, we studied the environmental change in isolation racks by forcibly suspending ventilation and air-conditioning and confirming the maximal time length for complete recovery to the original condition after restarting their operations. The isolation racks were placed in a room that was equipped with an independent air-conditioning system. When the inside condition of the racks reached 22-24 degrees C and 59-64% of relative humidity, the air-conditioning and ventilation were forcibly suspended and the subsequent temperature, relative humidity, ammonium and CO2 concentrations in the racks were measured over time. We found that after suspending the air-conditioning and ventilation, it took 40-60 min for temperature, and about 10 min for relative humidity to exceed the maximum values (temperature and relative humidity) referred to in the Showa 58 Nenban Guideline Jikken Doubutsu Shisetsu no Kenchiku oyobi Setsubi (Guidelines of buildings and facilities for experimental animals in Japan; Year 1983 edition). After 17 hr 25 min of the suspension of air-conditioning and ventilation, two rats were found dead. Then, the air-conditioning and ventilation were restarted. It took about 2 hr for temperature, and 50 min for relative humidity to regain the guideline values. The ammonium concentration stayed within the guideline value with a maximum concentration of 2 ppm in the experimental period, whereas the CO2 concentration was found to exceed 9% at the time of animal death.

  19. The microbiological quality of air improves when using air conditioning systems in cars.

    Science.gov (United States)

    Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F

    2010-06-01

    Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.

  20. Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad

    Directory of Open Access Journals (Sweden)

    Zainab Hasson Hassan

    2012-01-01

    Full Text Available This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. Laboratory tests were performed on a direct evaporative cooler (DEC followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%. The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, saturation efficiency of DEC, outlet temperature of air and cooling capacity. Heat transfer rate in heat exchanger mode is also estimated. The paper presents the mathematical development of the equations of thermal exchanges through DEC and HE. Prediction of air condition that exits o this system show that the present system could bring the air stream to a comfortable winter zone .

  1. Experimental Study of the APR+ Direct ECC Bypass in the Air-water Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kihwan; Choi, Hae-Seob; Park, Kil-won; Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The APR+ is an improved Korean Nuclear Power Reactor, which has been developed as a two loop evolutionary PWR (Pressure Water Reactor) with a number of advanced design features to enhance safety based on the APR-1400 technology. The emergency core cooling system (ECC) of the APR+ is different with that of the APR-1400, though the APR+ adopted a direct vessel injection (DVI) system which is the same design features of the APR-14000. The main difference of the DVI+ is the emergency core barrel duct (ECBD) which is designed to increase the amount of the injection water to the core region. The performance of the DVI system has been an important issues for past decades, and many researchers have studied the related thermal-hydraulic technical issues such as the ECC bypass fraction, the steam condensation effect, temperature distribution, sub-cooling margin, and etc. However, the previous research cannot be directly applicable to the APR+ owing to the unique features of the DVI+. The current study will elaborate on the experimental evaluation of the direct ECC bypass performance. The 1/5 ECC bypass test facility which is designed with a linearly reduced 1/5 scale referring to the APR+ was used to investigate the effect of the DVI+ injection nozzle location and the broken cold leg velocity on the direct ECC bypass fraction. However, air is used as a working fluid to simulate the steam flow induced from the broken cold leg, and thus, the direct contact condensation effect is not considered in this study. Experimental study for the direct ECC bypass phenomena has been carryout out with various the injection mode and air velocity conditions. The tests were performed in the 1/5 scale ECC bypass test facility, and the test condition was defined using a scaling law referring to the APR+ reactor. Test results showed that the direct ECC bypass fraction was greatly enhanced compared with the reference test (w/o ECBD)

  2. Nasal air conditioning in relation to acoustic rhinometry values.

    Science.gov (United States)

    Lindemann, Joerg; Tsakiropoulou, Evangelia; Keck, Tilman; Leiacker, Richard; Wiesmiller, Kerstin M

    2009-01-01

    Changes of nasal dimensions can influence the air-conditioning capacity of the nose because of alterations of airflow patterns. The goal of this study was to evaluate the correlation between intranasal temperature and humidity values and nasal dimensions, assessed by means of acoustic rhinometry. Eighty healthy volunteers (40 men and 40 women; median age, 51 years; range, 20-84 years) were enrolled in the study. In total, 160 nasal cavities were examined. All volunteers underwent a standardized acoustic rhinometry. Additionally, intranasal air temperature and humidity measurements at defined intranasal detection sites within the anterior nasal segment were performed. There was no statistically significant difference between the right and left side of the nose regarding air temperature, absolute humidity, and acoustic rhinometric values. A negative correlation was established between the rhinometric nasal volumes/minimal cross-sectional areas and air temperature and absolute humidity values at the three intranasal detection sites. According to our results, nasal volumes and cross- sectional areas relevantly influence nasal air conditioning. A healthy nasal cavity with smaller volumes and cross-sectional areas seems to present a more effective air-conditioning function than a too "wide" open nose because of changes in airflow patterns. This observation should be considered as a limitation for overly extensive nasal surgery especially of the turbinates.

  3. Facilities and the Air Force Systems Acquisition Process.

    Science.gov (United States)

    1985-05-01

    to provide es- senti-l fLcilitio-s by, system Initial Cperatlcnal Capability (’-0C) . And secondly, vince the systems ;acjui. tior proceso is event...funds exclusively for systems acquisition. This change will remove the current military construction calendar constraint and allow facilities to be

  4. Intelligent Control System of Textile Mill's Air-conditioning

    Institute of Scientific and Technical Information of China (English)

    WU Fu-zhuan; ZHAO Fang

    2009-01-01

    This paper briefly analyzes the present situation of textile mill's air-conditioning system. Since it is difficult to establish detailed math model to control a textile mill's air-conditioning system because of the influence of various factors such as the differences in seasons, regions, etc., most air-conditioning equipment can not he controlled automatically. This paper suggests utilizing multi-function data acquisition card to collect the data about the temperature and humidity of a workshop, processing the data on a PC, comparing them with the expert database, and then using the 485 serial port expanding module to output the parameters, which are used to control the inverter, so that the purpose of adjusting the temperature and humidity of the workshop is achieved.

  5. Sustainable air-conditioning for the tropical buildings

    Directory of Open Access Journals (Sweden)

    Asrul Mahjuddin Ressang Aminuddin

    2008-12-01

    Full Text Available Tropical climates are thermally uncomfortable and are mostly unhealthy to the occupants of the modern skyscrapers. The temperatures are usually on the hot side coupled with high relative humidity. The population living in the tropics, especially in Malaysia, is getting affluent and can afford air-conditioning their residences and offices. This leads to increased electricity consumption in the buildings. However, switching off the air-conditioning is not an option for the modern buildings as it would affect the health of the people and their productivity. This paper proposes innovative indoor units that will contribute to energy conservation by utilising principles of partial air-conditioning. The outdoor units could be utilised for clothes drying or for providing hot water to the occupants of the building. This will successfully address the issues on sustainable building technologies and techniques. It will lead to considerable savings in energy consumption in buildings in the tropical climate.

  6. AIR CONDITIONING IN MINES IN THE CZECH REPUBLIC AND UKRAINE

    Directory of Open Access Journals (Sweden)

    Pavel Zapletal

    2014-07-01

    Full Text Available The present-day micro-climatic conditions in black coal mines are of such nature that in no mine natural micro-climate conditioning is sufficient any more. The original temperature of rocks grows progressively in dependence on the increasing depth of the extracted seam, or more precisely, on the mining workplace, and this growth is much more significant than previously considered. The temperature of the surrounding rocks, but also high-performance continuous miners and conveyor belt drives heat up airflow, thus worsening microclimatic conditions. This article describes micro-climatic conditions the in Czech Republic and Ukraine and some methods of deep mines air conditioning.

  7. Development of Facility Type Information Packages for Design of Air Force Facilities.

    Science.gov (United States)

    1983-03-01

    evaluation. Technical evalution occurs most frequently at facility completion. Functional and behavioral evaluations must necessarily be post occupancy evaluations...after the users have "settled in." Post occupancy evaluations are analagous to that of the case study method in business--that is, to make...I- 0 The package is to be used for user evaluation of the facil- ity ( post - occupancy evaluation) and evaluation of the tech- nical and functional

  8. Air conditioning: Low-cost autonomous air conditioning systems for bionic buildings; Klimatechnik: Bezahlbare, autarke Klimatisierung von bionischen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, H. [ARCADIS, Maastricht (Netherlands); Kutzker, A. [RUBITHERM GmbH, Hamburg (Germany)

    2005-05-01

    Termites in Africa construct buildings that are respectfully referred to as ''cathedrals'' by experts. Millions of insects inhabit these structures that are efficiently air conditioned: While the outside temperatures vary from 10 C at night to 45 C in daytime, the air inside has a constant temperature of 29 C +/- 1 C. The contribution presents a low-cost solution for human buildings. (orig.)

  9. Key Technology and Experimental Results of the Clean Air Heated Facility for Supersonic Combustion

    Institute of Scientific and Technical Information of China (English)

    ZHONG Zipeng; SONG Wenyan; LE Jialing

    2009-01-01

    The scramjet, which is the propulsion of hypersonic vehicle, has become the focus in many military developed countries. The ground tests play an important role in the research of scramjet. There is defect of test medium contamination (the thermochemical characteristic of the ground test medium is different from that of the flight medium) in existing ground test facilities for scramjet combustor experiment. To solve the problem of test medium contamination, the first clean air heated facility of China for scramjet combustor experiment is designed. The key technology of designing the clean air heated facility is summarized. By using bypass duct, combustor model is protected from high temperature. To reduce the switching time between main duct and bypass duct, solenoid valve and water-cooled system were used. Having centrosymmetric structure, the heat radiating area of the facility and heat loss of the facility are much lower than others. Clean air heated facility is adopted to conduct experiment, which is the first experiment of China in clean air inflow, research on hydrogen-fueled and ethylene-fueled ignition and combustion for scramjet combustor at different equivalence ratio. Successful ignition and sustained combustion of hydrogen has been achieved. Successful ethylene ignition and sustained main stream combustion is achieved with normal fuel injection and taking hydrogen as pilot flame. Experiment result shows that the wall pressure of combustor model rises when the equivalence ratio of hydrogen rises. As the wall pressure of combustor model rises, the pressure disturbance influences the shock train in the upstream.

  10. Thermal stratification level of low sidewall air supply with air-conditioning system in large space

    Institute of Scientific and Technical Information of China (English)

    黄晨; 蔡宁; 高雪垒

    2009-01-01

    The thermal stratification level of low sidewall air supply system in large space was defined. Depending on the experiment of low sidewall air supply in summer 2008,the thermal stratification level was studied by simulation. Based on the simulation of experiment condition,the air velocity and vertical temperature distribution in a large space were simulated at different air-outlet velocities,and then the thermal stratification level line was obtained. The simulation results well match with the experimental ones and the average relative error is 3.4%. The thermal stratification level is heightened by increasing the air-outlet velocity with low sidewall air supply mode. It is concluded that when air-outlet velocity is 0.29 m/s,which is the experimental case,a uniform thermal environment in the higher occupied zone and a stable stratification level are formed. When the air-outlet velocity is low,such as 0.05 m/s,the thermal stratification level is too low and the air velocity is too small to meet the human thermal comfort in the occupied zone. So,it would be reasonable that the air-outlet velocity may be designed as 0.31 m/s if the height of the occupied zone is 2 m.

  11. Anthropogenic heating of the urban environment due to air conditioning

    Science.gov (United States)

    Salamanca, F.; Georgescu, M.; Mahalov, A.; Moustaoui, M.; Wang, M.

    2014-05-01

    This article investigates the effect of air conditioning (AC) systems on air temperature and examines their electricity consumption for a semiarid urban environment. We simulate a 10 day extreme heat period over the Phoenix metropolitan area (U.S.) with the Weather Research and Forecasting model coupled to a multilayer building energy scheme. The performance of the modeling system is evaluated against 10 Arizona Meteorological Network weather stations and one weather station maintained by the National Weather Service for air temperature, wind speed, and wind direction. We show that explicit representation of waste heat from air conditioning systems improved the 2 m air temperature correspondence to observations. Waste heat release from AC systems was maximum during the day, but the mean effect was negligible near the surface. However, during the night, heat emitted from AC systems increased the mean 2 m air temperature by more than 1°C for some urban locations. The AC systems modified the thermal stratification of the urban boundary layer, promoting vertical mixing during nighttime hours. The anthropogenic processes examined here (i.e., explicit representation of urban energy consumption processes due to AC systems) require incorporation in future meteorological and climate investigations to improve weather and climate predictability. Our results demonstrate that releasing waste heat into the ambient environment exacerbates the nocturnal urban heat island and increases cooling demands.

  12. Enabling Smart Air Conditioning by Sensor Development: A Review.

    Science.gov (United States)

    Cheng, Chin-Chi; Lee, Dasheng

    2016-11-30

    The study investigates the development of sensors, in particular the use of thermo-fluidic sensors and occupancy detectors, to achieve smart operation of air conditioning systems. Smart operation refers to the operation of air conditioners by the reinforcement of interaction to achieve both thermal comfort and energy efficiency. Sensors related to thermal comfort include those of temperature, humidity, and pressure and wind velocity anemometers. Improvements in their performance in the past years have been studied by a literature survey. Traditional occupancy detection using passive infra-red (PIR) sensors and novel methodologies using smartphones and wearable sensors are both discussed. Referring to the case studies summarized in this study, air conditioning energy savings are evaluated quantitatively. Results show that energy savings of air conditioners before 2000 was 11%, and 30% after 2000 by the integration of thermo-fluidic sensors and occupancy detectors. By utilizing wearable sensing to detect the human motions, metabolic rates and related information, the energy savings can reach up to 46.3% and keep the minimum change of predicted mean vote (∆PMV→0), which means there is no compromise in thermal comfort. This enables smart air conditioning to compensate for the large variations from person to person in terms of physiological and psychological satisfaction, and find an optimal temperature for everyone in a given space. However, this tendency should be evidenced by more experimental results in the future.

  13. Enabling Smart Air Conditioning by Sensor Development: A Review

    Directory of Open Access Journals (Sweden)

    Chin-Chi Cheng

    2016-11-01

    Full Text Available The study investigates the development of sensors, in particular the use of thermo-fluidic sensors and occupancy detectors, to achieve smart operation of air conditioning systems. Smart operation refers to the operation of air conditioners by the reinforcement of interaction to achieve both thermal comfort and energy efficiency. Sensors related to thermal comfort include those of temperature, humidity, and pressure and wind velocity anemometers. Improvements in their performance in the past years have been studied by a literature survey. Traditional occupancy detection using passive infra-red (PIR sensors and novel methodologies using smartphones and wearable sensors are both discussed. Referring to the case studies summarized in this study, air conditioning energy savings are evaluated quantitatively. Results show that energy savings of air conditioners before 2000 was 11%, and 30% after 2000 by the integration of thermo-fluidic sensors and occupancy detectors. By utilizing wearable sensing to detect the human motions, metabolic rates and related information, the energy savings can reach up to 46.3% and keep the minimum change of predicted mean vote (∆PMV→0, which means there is no compromise in thermal comfort. This enables smart air conditioning to compensate for the large variations from person to person in terms of physiological and psychological satisfaction, and find an optimal temperature for everyone in a given space. However, this tendency should be evidenced by more experimental results in the future.

  14. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    Science.gov (United States)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  15. Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C

    Energy Technology Data Exchange (ETDEWEB)

    Gary Mecham; Don Konoyer

    2009-11-01

    The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document conditions at time of transfer of the facilities from Nuclear Energy to Environmental Management and serve as the basis for disposition planning. The process used in obtaining this information included document searches, interviews and facility walk-downs. A copy of the facility walk-down checklist is included in this report as Appendix A. MFC-799/799A/770C are all structurally sound and associated hazardous or potentially hazardous conditions are well defined and well understood. All installed equipment items (tanks, filters, etc.) used to process hazardous materials remain in place and appear to have maintained their integrity. There is no evidence of leakage and all openings are properly sealed or closed off and connections are sound. The pits appear clean with no evidence of cracking or deterioration that could lead to migration of contamination. Based upon the available information/documentation reviewed and the overall conditions observed during the facilities walk-down, it is concluded that these facilities may be disposed of

  16. Ventilation and air-conditioning concept for CNGS underground areas

    CERN Document Server

    Lindroos, J

    2002-01-01

    The aim of the CNGS project is to prove the existence of neutrino oscillation by generating an intense neutrino beam from CERN in the direction of the Gran Sasso laboratory in Italy, where two large neutrino detectors are built to detect the neutrinos. All the components for producing the neutrino beam will be situated in the underground tunnels, service galleries and chambers. The ventilation and air-conditioning systems installed in these underground areas have multiple tasks. Depending on the operating mode and structure to be air-conditioned, the systems are required to provide fresh air, cool the machine, dehumidify areas housing sensible equipment or assure the smoke removal in a case of a fire. This paper presents the technical solutions foreseen to meet these requirements.

  17. Critical condition study of borehole stability during air drilling

    Institute of Scientific and Technical Information of China (English)

    Deng Jingen; Zou Linzhan; Tan Qiang; Yan Wei; Gao Deli; Zhang Hanlin; Yan Xiuliang

    2009-01-01

    The purpose of this paper is to establish the existence of the critical condition of borehole stability during air drilling.Rock Failure Process Analysis Code2D was used to set up a damage model of the borehole excavated in strain-softening rock.Damage evolution around the borehole was studied by tracking acoustic emission.The study indicates that excavation damaged zone (EDZ) is formed around borehole because of stress concentration after the borehole is excavated.There is a critical condition for borehole stability; the borehole will collapse when the critical damage condition is reached.The critical condition of underground excavation exists not only in elastic and ideal plastic material but in strain-softening material as well.The research is helpful to developing an evaluation method of borehole stability during air drilling.

  18. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    Directory of Open Access Journals (Sweden)

    Daniela Pinheiro da Silva

    2014-04-01

    Full Text Available Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acquired infections – HAI – as the air can be a potential source of infection, as well as assess the exposure of professionals and patients to different pollutants. Material and Methods: A literature review was performed in the LILACS, MEDLINE, SCIELO, SCIENCE DIRECT databases, CAPES thesis database and Ministry of Health – Brazil, including studies published between 1982 and 2008. The literature search was grouped according to the thematic focus, as follows: ventilation, maintenance and cleaning of systems that comprehend the environmental quality standard. Discussion and Conclusion: Outbreaks of hospital-acquired infections associated with Aspergillus, Acinetobacter, Legionella, and other genera such as Clostridium and Nocardia, which were found in air conditioners, were observed, thus indicating the need for air-conditioning quality control in these environments.

  19. Assessment of indoor air quality in comparison using air conditioning and fan system in printing premise

    Directory of Open Access Journals (Sweden)

    Ramlan Nazirah

    2017-01-01

    Full Text Available Printers contribute to various emissions consist with chemical contaminants. High concentration of the particulate matter can cause serious health problems. This study focuses on the indoor air quality in printing premise unit in Universiti Tun Hussein Onn, Malaysia. Field testing involving air sampling methods were taken from 900 hours to 1600 hours, for every 30 minutes using physical measurement which is Multi-Channel Air Quality Monitor (YESAIR, E-Sampler and Ozone Meter. Air sampling was recorded based on one sampling point and most suitable point for production. A comparison based on different ventilation using fan and air-conditioning were also taken and results is being compared based on OSHA and NIOSH standards. Besides that, the statistical analysis is being conducted in order to predict the effect on number of printers. From the result, the O3 concentrations show, 10% reduced for printing premise using fan ventilation compared to air-conditioning but remain the same value for PM2.5. The concentration of O3 increased when the number of printers decreased, while the concentration of PM2.5 increased the increase of printers number. Overall, the use of fan in printing premise is more suggested since the level is slightly lower than the printing premise using air-conditioning.

  20. An Analysis of the Air Conditioning, Refrigerating and Heating Occupation.

    Science.gov (United States)

    Frass, Melvin R.; Krause, Marvin

    The general purpose of the occupational analysis is to provide workable, basic information dealing with the many and varied duties performed in the air conditioning, refrigerating, and heating occupation. The document opens with a brief introduction followed by a job description. The bulk of the document is presented in table form. Six duties are…

  1. Step response and frequency response of an air conditioning system

    NARCIS (Netherlands)

    Crommelin, R.D.; Jackman, P.J.

    1978-01-01

    A system of induction units of an existing air conditioning system has been analyzed with respect to its dynamic properties. Time constants were calculated and measured by analogue models. Comparison with measurements at the installation itself showed a reasonable agreement. Frequency responses were

  2. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  3. State Skill Standards: Heating, Ventilation, Air Conditioning, and Refrigeration

    Science.gov (United States)

    Ball, Larry; Soukup, Dennis

    2006-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide career and technical education skill standards. The standards in this document are for Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) programs and are designed to clearly state what the student should know and be able to do upon completion of…

  4. Heating, Air-Conditioning, and Refrigeration Technician. National Skill Standards.

    Science.gov (United States)

    Vocational Technical Education Consortium of States, Decatur, GA.

    This guide contains information on the knowledge and skills identified by industry as essential to the job performance of heating, air-conditioning, and refrigeration technicians. It is intended to assist training providers in public and private institutions, as well as in industry, to develop and implement training that will provide workers with…

  5. Solar air conditioning researches and demonstrations in China

    Institute of Scientific and Technical Information of China (English)

    Wang Ruzhu

    2009-01-01

    This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.

  6. Rocket propulsion experimental facilities at the Phillips Laboratory, Edwards Air Force Base, California

    Science.gov (United States)

    Beckmann, Joel W.; Kalliomaa, Wayne M.

    The Phillips Laboratory has extensive rocket propulsion faciliteis at Edwards Air Force Base, California. These facilities range form small scale cells capable of firing liquid rocket engines as small as 0.01 lbf (0.04 Newtons (N)) thrust up to very large liquid/solid test stands designed for firings up to 10 million lbf (44.5 million N) thrust. This paper gives a review of the variety and capabilities of the numerous facilities at Edwards Air Force Base, as well as an overview of current projects. Emphasis is placed on the general capabilities of these facilities; specifics are available upon request to the author. Trends in the evolution of rocket test facilities are discussed.

  7. Modelling and simulation of air-conditioning cycles

    Science.gov (United States)

    Rais, Sandi; Kadono, Yoshinori; Murayama, Katsunori; Minakuchi, Kazuya; Takeuchi, Hisae; Hasegawa, Tatsuya

    2017-02-01

    The heat-pump cycle for air conditioning was investigated both numerically and experimentally by evaluating the coefficient of performance (COP) under Japanese Industrial Standard (JIS B 8619:1999) and ANSI/AHRI standard 750-2007 operating conditions. We used two expansion valve coefficients Cv_{(φ)} = 0.12 for standard operating conditions (Case 1) approaching 1.3 MPa at high pressure and 0.2 MPa at low pressure, and Cv_{(φ)} = 0.06 namely poor operating conditions (Case 2). To improve the performance of the air conditioner, we compared the performance for two outside air temperatures, 35 and 40 °C (Case 3). The simulation and experiment comparison resulted the decreasing of the COP for standard operating condition is equal to 14 %, from 3.47 to 2.95 and a decrease of the cooling capacity is equal to 18 %, from 309.72 to 253.53 W. This result was also occurred in poor operating condition which the COP was superior at 35 °C temperature.

  8. Ontology for Life-Cycle Modeling of Heating, Ventilating, and Air Conditioning (HVAC) Systems: Experimental Applications Using Revit

    Science.gov (United States)

    2012-03-01

    Center, Construction Engineering Research Laboratory (ERDC-CERL) has developed a core life- cycle building information model ( BIM ) based on three...was to promote consistency and quality of content created for Building Information Models ( BIMs ) across various disciplines. The HVAC MVD was...MVD. 15. SUBJECT TERMS building information modeling ( BIM ), ontology, Army facilities, heating, ventilating, and air-conditioning (HVAC) systems

  9. A strategy for oxygen conditioning at high altitude: comparison with air conditioning.

    Science.gov (United States)

    West, John B

    2015-09-15

    Large numbers of people live or work at high altitude, and many visit to trek or ski. The inevitable hypoxia impairs physical working capacity, and at higher altitudes there is also cognitive impairment. Twenty years ago oxygen enrichment of room air was introduced to reduce the hypoxia, and this is now used in dormitories, hotels, mines, and telescopes. However, recent advances in technology now allow large amounts of oxygen to be obtained from air or cryogenic oxygen sources. As a result it is now feasible to oxygenate large buildings and even institutions such as hospitals. An analogy can be drawn between air conditioning that has improved the living and working conditions of millions of people who live in hot climates and oxygen conditioning that can do the same at high altitude. Oxygen conditioning is similar to air conditioning except that instead of cooling the air, the oxygen concentration is raised, thus reducing the equivalent altitude. Oxygen conditioning on a large scale could transform living and working conditions at high altitude, where it could be valuable in homes, hospitals, schools, dormitories, company headquarters, banks, and legislative settings. Copyright © 2015 the American Physiological Society.

  10. Control System Functional Criteria for Modernized Forced Air Dry Facility

    Science.gov (United States)

    1982-11-01

    SOLUTION SUPPLY is to provide caustic water of fixed composition and volume to CAUSTIC REACTION. The technology used is to mix caustic soda and water in a...2.1.1.1 TK-7: provides holdup for batch preparation. 2.1.1.2 AG-1: provides for the mixing of caustic soda and water. 2.1.1.3 P-11: provides...air stream in the caustic scrubber. A con- trolled environment for prototype plant studies must be established since not enough is known about this

  11. Hollow Fiber Membrane Dehumidification Device for Air Conditioning System.

    Science.gov (United States)

    Zhao, Baiwang; Peng, Na; Liang, Canzeng; Yong, Wai Fen; Chung, Tai-Shung

    2015-11-16

    In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18-22 g/m³ to a range of 13.5-18.3 g/m³. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process.

  12. Hollow Fiber Membrane Dehumidification Device for Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Baiwang Zhao

    2015-11-01

    Full Text Available In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18–22 g/m3 to a range of 13.5–18.3 g/m3. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process.

  13. Monitoring plan for routine organic air emissions at the Radioactive Waste Management Complex Waste Storage Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Galloway, K.J.; Jolley, J.G.

    1994-06-01

    This monitoring plan provides the information necessary to perform routine organic air emissions monitoring at the Waste Storage Facilities located at the Transuranic Storage Area of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The Waste Storage Facilities include both the Type I and II Waste Storage Modules. The plan implements a dual method approach where two dissimilar analytical methodologies, Open-Path Fourier Transform Infrared Spectroscopy (OP-FTIR) and ancillary SUMMA{reg_sign} canister sampling, following the US Environmental Protection Agency (EPA) analytical method TO-14, will be used to provide qualitative and quantitative volatile organic concentration data. The Open-Path Fourier Transform Infrared Spectroscopy will provide in situ, real time monitoring of volatile organic compound concentrations in the ambient air of the Waste Storage Facilities. To supplement the OP-FTIR data, air samples will be collected using SUMMA{reg_sign}, passivated, stainless steel canisters, following the EPA Method TO-14. These samples will be analyzed for volatile organic compounds with gas chromatograph/mass spectrometry analysis. The sampling strategy, procedures, and schedules are included in this monitoring plan. The development of this monitoring plan is driven by regulatory compliance to the Resource Conservation and Recovery Act, State of Idaho Toxic Air Pollutant increments, Occupational Safety and Health Administration. The various state and federal regulations address the characterization of the volatile organic compounds and the resultant ambient air emissions that may originate from facilities involved in industrial production and/or waste management activities.

  14. Feedback linearization based control of a variable air volume air conditioning system for cooling applications.

    Science.gov (United States)

    Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik

    2008-07-01

    Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.

  15. Nasal air-conditioning after partial turbinectomy: myths versus facts.

    Science.gov (United States)

    Tsakiropoulou, Evangelia; Vital, Victor; Constantinidis, Jannis; Kekes, George

    2015-01-01

    Turbinectomy, although a common procedure, is often accused of having a negative impact in all nasal functions. This study is the first in vivo study that evaluates objectively the effect of partial turbinectomy on nasal air-conditioning capacity. In total, 57 patients with prior partial inferior turbinectomy and 28 healthy controls were examined. Intranasal temperature and humidity values were measured at the level of the head of inferior and middle turbinate. Nasal patency was evaluated by means of acoustic rhinometry. The clinical assessment was completed with nasal endoscopy and the Nasal Obstruction Symptom Evaluation questionnaire for subjective evaluation of nasal patency. Significant changes of temperature were found in both detection sites with 13% reduced heating capacity of the air at the level of the inferior and 19% at the level of the middle turbinate, respectively. No similar results were found for humidity measurements. No correlations were found between air-conditioning values and acoustic rhinometry results for both study groups. Nasal endoscopy revealed normal healing in all patients. No major complications were reported by the patients. Their subjective ratings of nasal obstruction were similar to healthy controls. Partial turbinectomy seems to have a negative impact on intranasal air heating but not to humidification. This effect has no impact on clinical condition and subjective perception of surgical outcome.

  16. Design and Implementation of Air Conditioning System in Operating Room

    Directory of Open Access Journals (Sweden)

    Htet Htet Aung

    2014-10-01

    Full Text Available The system is air conditioning system in operating room. The main objective of the system was implemented to provide air balance and temperature necessary conditions and to control airflow system for ventilation units in operating room. The operation room can be controlled with fuzzy expert system and describes the desired outputs. Input parameters such as temperature, humidity, oxygen and particle are used and output parameters are chosen as air conditioning motor speed and exhaust motor speed. Input parameters of the system are taken into account optimal conditions based on oxygen as medium and other parameters are chosen minimum condition for operating room. The airflow control system is determined the two components: the airflow block and the thermal block for ventilation units in operating room. The mathematical modeling of each such system based on a computational procedure and to combine them together in an efficient manner. Whether it supports to the most suitable control for the system prototype was determined by simulating the operation with varying the number of personnel and duration of time. Finally, according to the combination of temperature and airflow regulations with PI controller, the results of simulation of the entire ventilation unit control system is obtained.

  17. Using Firn Air for Facility Cooling at the WAIS Divide Site

    Science.gov (United States)

    2014-09-17

    Expedition NICL National Ice core Laboratory NSF National Science Foundation PLR Division of Polar Programs USAP United States Antarctic Program WAIS...ER D C/ CR RE L TR -1 4- 19 Engineering for Polar Operations, Logistics, and Research (EPOLAR) Using Firn Air for Facility Cooling at...acwc.sdp.sirsi.net/client/default. Engineering for Polar Operations, Logistics, and Research (EPOLAR) ERDC/CRREL TR-14-19 September 2014 Using Firn Air for

  18. A survey of energy efficient strategies for effective air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Al-Rabghi, O.M.; Akyurt, M.M. [King Abdulaziz University, Jeddah (Saudi Arabia). Dept. of Mechanical Engineering

    2004-07-01

    Several methods are presented for lowering the energy consumed during air conditioning of buildings. Some of these strategies can be implemented during the design stage; others can be used to retrofit existing AC systems; and still others can be applied with hardly any changes on existing equipment. The methods that are discussed include heat recovery and utilization, absorption refrigeration systems, thermal cool storage, liquid (refrigerant) pressure amplification, reprogramming of the AC control systems, economical methods of removal of moisture from the air and initiation of awareness programs for the conservation of A/C energy. (author)

  19. Calculation methods for air supply design in industrial facilities. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hagstroem, K.; Siren, K.; Zhivov, A.M.

    1999-09-01

    The objectives of air distribution systems for warm air heating, ventilating, and air-conditioning are to create the proper thermal environment conditions in the occupied zone (combination of temperature, humidity, and air movement), and to control vapor and air born particle concentration within the target levels set by the process requirements and/or threshold limit values based on health effects, fire and explosion prevention, or other considerations. HVAC systems designs are constrained by existing codes, standards, and guidelines, which specify some minimum requirements for the HVAC system elements, occupant`s and process environmental quality and safety. There is a variety of different methods consulting engineers use to design room air diffusion and to select and size air diffusers, such as assumption of perfect mixing, design methods employing the empirical relations determined through research, such as the air diffusion performance index (ADPI), air jet theory and computational fluid dynamics (CFD) codes. Air supplied into the room through the various types of outlets (grills, ceiling mounted air diffusers, perforated panels etc.), is distributed by turbulent air jets. In mixing type air distribution systems, these air jets are the primary factor affecting room air motion. Numerous theoretical and experimental studies that developed a solid base for turbulent air jets theory were conducted concurrently in different countries (Germany, Sweden, Russia, U.K., USA) from the 1930`s through the 1980`s. Design methods based on air jet theory allows for the prediction of extreme values of air velocities and air temperatures in the occupied zone of empty spaces. Current air jet theory techniques account for the effects of buoyancy, confinement, jets interaction. For many conditions of jet discharge, it is possible to analyze jet performance and determine: the angle of divergence of the jet boundary; the velocity patterns along heated or chilled the jet axis; the

  20. Production and exploitation of thermoelectric air conditioning systems for vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Dudnik, Vladimir [Conditioner Ltd, Gagarin (Russian Federation); Skipidarov, Sergey [SCTB NORD, Moskau (Russian Federation); Rapp, Axel [Quick-Ohm Kupper und Co. GmbH, Wuppertal-Cronenberg (Germany)

    2011-07-01

    In the paper more than 10-year experience of thermoelectric devices batch manufacturing is described for the field of their obvious advantages. This field of application includes thermoelectric air conditioning systems which have shown their competitive advantage when used in vehicles of elevated vibration where compressor equipment application is difficult because of leakage of refrigerant. Energy characteristics of air conditioners for tractors, excavators, tanks, locomotive driver's cabins and cranes are described. Thermoelectric (TE) air conditioners mechanical test data as well as operation experience in vehicles are presented. It is shown that consumption of tellurium, which is a strategic component for thermoelectric materials manufacturing, may be lowered to 40 grams per 1 kW of cooling. (orig.)

  1. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Boeder, A; Zimm, C

    2006-09-30

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate

  2. A Technical Basis for Employing Facility Ventilation Air Exchange Rates in the Decision to Downpost

    CERN Document Server

    Mantooth, D S

    2001-01-01

    Utilizing the ventilation exchange rate as a basis for the decision to downpost a location within a facility from an airborne radiation area (ARA) based on initial air count(DAC). Not used in the case of a confirmed or suspected contamination release.

  3. EPA Region 2 AIRS FACILITY SUBSYSTEM (AIRS-AFS) GIS Layer

    Data.gov (United States)

    U.S. Environmental Protection Agency — This ArcGIS 10.2 point feature class contains identification, location and status information for EPA Region 2 facilities (NYS, NJ, Puerto Rico and the US Virgin...

  4. Development of nanolubricant automotive air conditioning (AAC test rig

    Directory of Open Access Journals (Sweden)

    Redhwan A.A.M.

    2017-01-01

    Full Text Available Nanolubricant been introduced in compressor might improve the performance of automotive air conditioning system. Prior testing of the nanolubricant enhancement performance, an automotive air conditioning (AAC system test rig base on compact car has to be developed; therefore this paper presented the development process of AAC test rig. There are 15 thermocouples, 2 pressure gauges and power analyzer were assembled on the system in order to analyse its performance. The experiment was conducted with four different charged of refrigerant. The charging was based on initial weight charged. At each quantity of refrigerant charge, performance of the AAC system was evaluated by determining three important parameters which is cooling capacity, compressor work and coefficient of performance (COP. The maximum average COP is achieved at 900 RPM is 7.07. The average and maximum COP enhancement of 7.07 % and 13.34 % were achieved by applying SiO2 nanolubricant inside the compressor.

  5. Working fluid concentration measurement in solar air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.J.; Basurto-Pensado, M.A. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001. Col. Chamilpa, C.P. 62210, Cuernavaca, Morelos (Mexico); Jimenez-Heredia, A.H.; Sanchez-Mondragon, J.J. [Departamento de Optica, Instituto Nacional de Astrofisica Optica y Electronica, Luis Enrique Erro No. 1, Tonantzintla, Apartado Postal 51 y 216, C.P. 72000, Puebla (Mexico)

    2006-02-15

    In order to evaluate on-line corrosive electrolyte concentration in solar air conditioning systems, an optical technique to determine the concentration is being proposed. With this optical sensing method, it is possible to measure the percentage concentration of the aqueous corrosive lithium bromide solution at temperatures ranging from 25{sup o}C to 70{sup o}C and a maximum concentration of 60%. The measurement system is based on the refractive index of the solution and the data correlation, at several temperature and concentration values. The results of this work present a direct method for concentration measurement of corrosive liquids and also show the correlation among the three parameters: refractive index, temperature and weight concentration. This correlation can be used to develop the optical device for solar air conditioning systems to control and improve efficiency. (author)

  6. [Air conditioning units and warm air blankets in the operating room].

    Science.gov (United States)

    Kerwat, Klaus; Piechowiak, Karolin; Wulf, Hinnerk

    2013-01-01

    Nowadays almost all operating rooms are equipped with air conditioning (AC units). Their main purpose is climatization, like ventilation, moisturizing, cooling and also the warming of the room in large buildings. In operating rooms they have an additional function in the prevention of infections, especially the avoidance of postoperative wound infections. This is achieved by special filtration systems and by the creation of specific air currents. Since hypothermia is known to be an unambiguous factor for the development of postoperative wound infections, patients are often actively warmed intraoperatively using warm air blankets (forced-air warming units). In such cases it is frequently discussed whether such warm air blankets affect the performance of AC units by changing the air currents or whether, in contrast, have exactly the opposite effect. However, it has been demonstrated in numerous studies that warm air blankets do not have any relevant effect on the functioning of AC units. Also there are no indications that their use increases the rate of postoperative wound infections. By preventing the patient from experiencing hypothermia, the rate of postoperative wound infections can even be decreased thereby. © Georg Thieme Verlag Stuttgart · New York.

  7. Solar air-conditioning-active, hybrid and passive

    Energy Technology Data Exchange (ETDEWEB)

    Yellott, J. I.

    1981-04-01

    After a discussion of summer air conditioning requirements in the United States, active, hybrid, and passive cooling systems are defined. Active processes and systems include absorption, Rankine cycle, and a small variety of miscellaneous systems. The hybrid solar cooling and dehumidification technology of desiccation is covered as well as evaporative cooling. The passive solar cooling processes covered include convective, radiative and evaporative cooling. Federal and state involvement in solar cooling is then discussed. (LEW)

  8. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    Approved for public release: distribution unlimited TDS-NAVFAC-EXWC-PW-1603 Sep 2016 HVAC ; Heating, Ventilation, Air Conditioning - Aerosol...energy consumption, depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is...Although several studies have been done on the effectiveness of sealing leaky HVAC ductwork with aerosol duct sealant, few studies have been done on

  9. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    OpenAIRE

    H. Mirinejad; Sadati, S.H.; M Ghasemian; H. Torab

    2008-01-01

    Problem statement: Heating, Ventilating and Air Conditioning (HVAC) systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort fiel...

  10. Persistence of initial conditions in continental scale air quality ...

    Science.gov (United States)

    This study investigates the effect of initial conditions (IC) for pollutant concentrations in the atmosphere and soil on simulated air quality for two continental-scale Community Multiscale Air Quality (CMAQ) model applications. One of these applications was performed for springtime and the second for summertime. Results show that a spin-up period of ten days commonly used in regional-scale applications may not be sufficient to reduce the effects of initial conditions to less than 1% of seasonally-averaged surface ozone concentrations everywhere while 20 days were found to be sufficient for the entire domain for the spring case and almost the entire domain for the summer case. For the summer case, differences were found to persist longer aloft due to circulation of air masses and even a spin-up period of 30 days was not sufficient to reduce the effects of ICs to less than 1% of seasonally-averaged layer 34 ozone concentrations over the southwestern portion of the modeling domain. Analysis of the effect of soil initial conditions for the CMAQ bidirectional NH3 exchange model shows that during springtime they can have an important effect on simulated inorganic aerosols concentrations for time periods of one month or longer. The effects are less pronounced during other seasons. The results, while specific to the modeling domain and time periods simulated here, suggest that modeling protocols need to be scrutinized for a given application and that it cannot be assum

  11. High Technology Centrifugal Compressor for Commercial Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ruckes, John

    2006-04-15

    R&D Dynamics, Bloomfield, CT in partnership with the State of Connecticut has been developing a high technology, oil-free, energy-efficient centrifugal compressor called CENVA for commercial air conditioning systems under a program funded by the US Department of Energy. The CENVA compressor applies the foil bearing technology used in all modern aircraft, civil and military, air conditioning systems. The CENVA compressor will enhance the efficiency of water and air cooled chillers, packaged roof top units, and other air conditioning systems by providing an 18% reduction in energy consumption in the unit capacity range of 25 to 350 tons of refrigeration The technical approach for CENVA involved the design and development of a high-speed, oil-free foil gas bearing-supported two-stage centrifugal compressor, CENVA encompassed the following high technologies, which are not currently utilized in commercial air conditioning systems: Foil gas bearings operating in HFC-134a; Efficient centrifugal impellers and diffusers; High speed motors and drives; and System integration of above technologies. Extensive design, development and testing efforts were carried out. Significant accomplishments achieved under this program are: (1) A total of 26 builds and over 200 tests were successfully completed with successively improved designs; (2) Use of foil gas bearings in refrigerant R134a was successfully proven; (3) A high speed, high power permanent magnet motor was developed; (4) An encoder was used for signal feedback between motor and controller. Due to temperature limitations of the encoder, the compressor could not operate at higher speed and in turn at higher pressure. In order to alleviate this problem a unique sensorless controller was developed; (5) This controller has successfully been tested as stand alone; however, it has not yet been integrated and tested as a system; (6) The compressor successfully operated at water cooled condensing temperatures Due to temperature

  12. Visualization of the influence of the air conditioning system to the high-power laser beam quality with the modulation coherent imaging method.

    Science.gov (United States)

    Tao, Hua; Veetil, Suhas P; Pan, Xingchen; Liu, Cheng; Zhu, Jianqiang

    2015-08-01

    Air conditioning systems can lead to dynamic phase change in the laser beams of high-power laser facilities for the inertial confinement fusion, and this kind of phase change cannot be measured by most of the commonly employed Hartmann wavefront sensor or interferometry due to some uncontrollable factors, such as too large laser beam diameters and the limited space of the facility. It is demonstrated that this problem can be solved using a scheme based on modulation coherent imaging, and thus the influence of the air conditioning system on the performance of the high-power facility can be evaluated directly.

  13. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis(®)μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis(®)μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis(®)μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis(®)μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  14. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    %. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion....... Binary Ice as secondary refrigerant for air-conditioning purposes is an economical and technically feasible solution in any climate. Whatever chilled water can do in an air-conditioning installation ? Binary Ice can do it better....... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  15. A calibration facility to provide traceable calibration to upper air humidity measuring sensors

    Science.gov (United States)

    Cuccaro, Rugiada; Rosso, Lucia; Smorgon, Denis; Beltramino, Giulio; Fernicola, Vito

    2017-04-01

    Accurate knowledge and high quality measurement of the upper air humidity and of its profile in atmosphere is essential in many areas of the atmospheric research, for example in weather forecasting, environmental pollution studies and research in meteorology and climatology. Moving from the troposphere to the stratosphere, the water vapour amount varies between some percent to few part per million. For this reason, through the years, several methods and instruments have been developed for the measurement of the humidity in atmosphere. Among the instruments used for atmospheric sounding, radiosondes, airborne and balloon-borne chilled mirror hygrometer (CMH) and tunable diode laser absorption spectrometers (TDLAS) play a key role. To avoid the presence of unknown biases and systematic errors and to obtain accurate and reliable humidity measurements, these instruments need a SI-traceable calibration, preferably carried out in conditions similar to those expected in the field. To satisfy such a need, a new calibration facility has been developed at INRIM. The facility is based on a thermodynamic-based frost-point generator designed to achieve a complete saturation of the carrier gas with a single passage through an isothermal saturator. The humidity generator covers the frost point temperature range between -98 °C and -20 °C and is able to work at any controlled pressure between 200 hPa and 1000 hPa (corresponding to a barometric altitude between ground level and approximately 12000 m). The paper reports the work carried out to test the generator performances, discusses the results and presents the evaluation of the measurement uncertainty. The present work was carried out within the European Joint Research Project "MeteoMet 2 - Metrology for Essential Climate Variables" co-funded by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

  16. Experimental analysis of fuzzy controlled energy efficient demand controlled ventilation economizer cycle variable air volume air conditioning system

    Directory of Open Access Journals (Sweden)

    Rajagopalan Parameshwaran

    2008-01-01

    Full Text Available In the quest for energy conservative building design, there is now a great opportunity for a flexible and sophisticated air conditioning system capable of addressing better thermal comfort, indoor air quality, and energy efficiency, that are strongly desired. The variable refrigerant volume air conditioning system provides considerable energy savings, cost effectiveness and reduced space requirements. Applications of intelligent control like fuzzy logic controller, especially adapted to variable air volume air conditioning systems, have drawn more interest in recent years than classical control systems. An experimental analysis was performed to investigate the inherent operational characteristics of the combined variable refrigerant volume and variable air volume air conditioning systems under fixed ventilation, demand controlled ventilation, and combined demand controlled ventilation and economizer cycle techniques for two seasonal conditions. The test results of the variable refrigerant volume and variable air volume air conditioning system for each techniques are presented. The test results infer that the system controlled by fuzzy logic methodology and operated under the CO2 based mechanical ventilation scheme, effectively yields 37% and 56% per day of average energy-saving in summer and winter conditions, respectively. Based on the experimental results, the fuzzy based combined system can be considered to be an alternative energy efficient air conditioning scheme, having significant energy-saving potential compared to the conventional constant air volume air conditioning system.

  17. Effect of Intake Air Filter Condition on Vehicle Fuel Economy

    Energy Technology Data Exchange (ETDEWEB)

    Norman, Kevin M [ORNL; Huff, Shean P [ORNL; West, Brian H [ORNL

    2009-02-01

    The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy and the U.S. Environmental Protection Agency (EPA) jointly maintain a fuel economy website (www.fueleconomy.gov), which helps fulfill their responsibility under the Energy Policy Act of 1992 to provide accurate fuel economy information [in miles per gallon (mpg)] to consumers. The site provides information on EPA fuel economy ratings for passenger cars and light trucks from 1985 to the present and other relevant information related to energy use such as alternative fuels and driving and vehicle maintenance tips. In recent years, fluctuations in the price of crude oil and corresponding fluctuations in the price of gasoline and diesel fuels have renewed interest in vehicle fuel economy in the United States. (User sessions on the fuel economy website exceeded 20 million in 2008 compared to less than 5 million in 2004 and less than 1 million in 2001.) As a result of this renewed interest and the age of some of the references cited in the tips section of the website, DOE authorized the Oak Ridge National Laboratory (ORNL) Fuels, Engines, and Emissions Research Center (FEERC) to initiate studies to validate and improve these tips. This report documents a study aimed specifically at the effect of engine air filter condition on fuel economy. The goal of this study was to explore the effects of a clogged air filter on the fuel economy of vehicles operating over prescribed test cycles. Three newer vehicles (a 2007 Buick Lucerne, a 2006 Dodge Charger, and a 2003 Toyota Camry) and an older carbureted vehicle were tested. Results show that clogging the air filter has no significant effect on the fuel economy of the newer vehicles (all fuel injected with closed-loop control and one equipped with MDS). The engine control systems were able to maintain the desired AFR regardless of intake restrictions, and therefore fuel consumption was not increased. The carbureted engine did show a decrease in

  18. Report of study 7.3: cooling and air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.

    2000-07-01

    This report describes the results of the study carried out by the study group 7.3 in the triennium 1997-2000. The study was focused on industrial refrigeration and air conditioning for the large building utilising natural gas. The goal of this study, carried out in collaboration of the members of study group 7.3, was to analyse the markets of industrial refrigeration and air conditioning for large buildings to identify possibilities to increase the natural gas share in these sectors. The available technology in the two sectors of the market are described in a single section, i.e. the 'State of the art of the technology'. In this section, technical characteristics, applications, performances, new developments and others topics are discussed for absorbers, gas engines, gas turbines and fuel cells. In the 'Industrial Refrigeration' section an analysis of the present global market for the industrial sector is presented. Economics, advantages and barriers to gas units compared with the electrical units are discussed. Information on existing industrial plants, possible application options and new technology developments are described as well. The 'Air conditioning for the large building' section deals with offices, hotels, commercial buildings, hospitals and shopping centres with a cooling capacity of 350 kW or higher. It appears that the use of natural gas for cooling of large buildings has been increasing during the last decade, thanks to the greater availability of natural gas and the development of new technologies. A marketing survey of gas air-conditioning was carried out in cooperation with a group of Intergas Marketing. Based on the survey, the report describes the market position of natural gas relative to electricity. It provides the strategic prospects for further developing natural gas as a competitive option for air-conditioning of large buildings using a combination of state-of-the-art technologies. It is important to highlight

  19. A mixed air/air and air/water heat pump system ensures the air-conditioning of a cinema; Un systeme mixte PAC air/air et air/eau climatise un cinema

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-03-01

    This article presents the air conditioning system of a new cinema complex of Boulogne (92, France) which comprises a double-flux air processing plant and two heat pumps. Each heat pump has two independent refrigerating loops: one with a air condenser and the other with a water condenser. This system allows to limit the power of the loop and to reduce the size of the cooling tower and of the vertical ducts. This article describes the technical characteristics of the installation: thermodynamic units, smoke clearing, temperature control, air renewing. (J.S.)

  20. Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.; Lowenstein, A.

    2014-09-01

    Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

  1. Membrane-based air conditioning. Decentral desiccant cooling; Membranbasierte Raumklimatisierung. Dezentrale sorptionsgestuetzte Klimatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Hannes [Institut fuer Luft- und Kaeltetechnik gGmbH, Dresden (Germany)

    2012-04-15

    Semipermeable membranes have a considerable potential use in air conditioning systems due to their properties. As water resistant but water vapor permeable functional separation layers, they allow desiccant air-conditioning processes in decentral air conditioning systems and a condensate-free air dehumidification at cooling ceiling elements. (orig.)

  2. Persistence of initial conditions in continental scale air quality simulations

    Science.gov (United States)

    Hogrefe, Christian; Roselle, Shawn J.; Bash, Jesse O.

    2017-07-01

    This study investigates the effect of initial conditions (IC) for pollutant concentrations in the atmosphere and soil on simulated air quality for two continental-scale Community Multiscale Air Quality (CMAQ) model applications. One of these applications was performed for springtime and the second for summertime. Results show that a spin-up period of ten days commonly used in regional-scale applications may not be sufficient to reduce the effects of initial conditions to less than 1% of seasonally-averaged surface ozone concentrations everywhere while 20 days were found to be sufficient for the entire domain for the spring case and almost the entire domain for the summer case. For the summer case, differences were found to persist longer aloft due to circulation of air masses and even a spin-up period of 30 days was not sufficient to reduce the effects of ICs to less than 1% of seasonally-averaged layer 34 ozone concentrations over the southwestern portion of the modeling domain. Analysis of the effect of soil initial conditions for the CMAQ bidirectional NH3 exchange model shows that during springtime they can have an important effect on simulated inorganic aerosols concentrations for time periods of one month or longer. The effects are less pronounced during other seasons. The results, while specific to the modeling domain and time periods simulated here, suggest that modeling protocols need to be scrutinized for a given application and that it cannot be assumed that commonly-used spin-up periods are necessarily sufficient to reduce the effects of initial conditions on model results to an acceptable level. What constitutes an acceptable level of difference cannot be generalized and will depend on the particular application, time period and species of interest. Moreover, as the application of air quality models is being expanded to cover larger geographical domains and as these models are increasingly being coupled with other modeling systems to better represent

  3. Laboratory facility to create reference radon + thoron atmosphere under dynamic exposure conditions.

    Science.gov (United States)

    Pressyanov, D; Mitev, K; Georgiev, S; Dimitrova, I; Kolev, J

    2017-01-01

    Radon ((222)Rn) and thoron ((220)Rn) levels in the environment are typically subject to significant random and systematic variations. Creation in the laboratory of reproducible and controlled exposure conditions close to that in the real environment can be useful for testing (222)Rn and (220)Rn detectors and for research. In this report the design and performance of a novel laboratory facility with such functionality is presented. The facility allows the exposure of detectors under controlled dynamic as well as static activity concentrations of (222)Rn and (220)Rn (pure and mixed) and temperature. The temperature is measured and regulated within -15 °C ÷ +60 °C by a dedicated programmable thermostat. Different reference activity concentrations in the exposure vessel are made by regulating the flow-rate of the air that flushes (222)Rn/(220)Rn activity from the sources towards the exposure vessel. Reference atmospheres that contain (222)Rn, (220)Rn or a specified ratio of the two can be created. Pilot experiments that demonstrate the feasibility of the approach are presented. They include follow-up of a pre-defined temperature profile (in the range -5 °C ÷ +35 °C), test of the correspondence between planned and measured (222)Rn and (220)Rn activity concentrations, follow-up of a pre-defined dynamic profile of (220)Rn concentrations and test of the possibility to create mixed (220)Rn/(222)Rn atmospheres (experimentally checked for ratio of the activity concentrations from 0.27 to 4.5). The results from the experimental tests are in agreement with the values obtained by the developed theoretical model. The proposed approach can be used to plan and create stationary and dynamic reference exposure conditions that are close to the real exposure regimes in the environment.

  4. Monitoring of fungal spores in the indoor air of preschool institution facilities in Novi Sad

    Directory of Open Access Journals (Sweden)

    Novaković Milana S.

    2013-01-01

    Full Text Available Fungal spores can cause a range of health problems in humans such as respiratory diseases and mycotoxicoses. Since children are the most vulnerable, the presence of fungal spores in the facilities of preschool and school institutions should be investigated readily. In order to estimate air contamination by fungal spores, air sampling was conducted in eight facilities of the preschool institution in Novi Sad during February and March, 2007. Sedimentation plate method was used for the detection of viable fungal spores, mostly being members of subdv. Deuteromycota (Fungi imperfecti. In 32 samples a total of 148 colonies were developed, among which five genera were identified: Penicillium, Cladosporium, Aspergillus, Alternaria and Acremonium while non-sporulating fungal colonies were labeled as sterile mycelia. Most frequently recorded genera were Penicillium with 46 colonies and Cladosporium with 44 colonies. The genera Aspergillus and Alternaria were represented with 3 colonies each and Acremonium with only 1 colony. The greatest number of colonies emerged in the samples from the day care facilities “Vendi” (58 colonies and “Panda” (49 colonies. Most diverse samples were obtained from the day care center “Zvončica”, with presence of all identified genera. These results showed notable presence of fungal spores in the indoor air of Preschool institution facilities and indicated the need for further, more complete seasonal research. Obtained information is considered useful for the evaluation of potential mycofactors that endanger health of children. [Projekat Ministarstva nauke Republike Srbije, br. III43002

  5. The Predictive Control Method of VAV Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Jiejia LI

    2013-09-01

    Full Text Available Aiming at the characteristics which variable air volume air conditioning system is multi-variable, nonlinear and uncertain system, normal fuzzy neural network is hard to meet the requirements which dynamic control of multi-variable. In this paper, we put forward a recursive neural network predictive control strategy based on wavelet neural network model. Through recursive wavelet neural network predictor on line established controlled object’s mathematical model, and using Elman neural network controller on line corrected information we get, thus to improve control effect. The simulation results show that recursive wavelet neural network predictive control has stronger robustness and adaptive ability, high control precision, better and reliable control effect and other advantages.

  6. Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.

    Science.gov (United States)

    Pujades, M C; Granero, D; Vijande, J; Ballester, F; Perez-Calatayud, J; Papagiannis, P; Siebert, F A

    2014-12-01

    In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by (192)Ir and (60)Co will reduce the lead thickness by a factor of five for (192)Ir and ten for (60)Co. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers.The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness.

  7. Sufficient conditions for optimal facility locations to coincide

    DEFF Research Database (Denmark)

    Juel, Henrik; Love, Robert F.

    1980-01-01

    In some cases multifacility location problems may be solved by verifying a few simple inequalities involving the interfacility weights. The authors develop certain inequalities which are sufficient conditions for optimality in some multifacility problems. In the problems considered, distances are...

  8. Thermo economical evaluation of retrofitting strategies in air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Tribess, Arlindo; Fiorelli, Flavio Augusto Sanzogo; Hernandez Neto, Alberto [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia Mecanica]. E-mail: atribess@usp.br; fiorelli@usp.br; ahneto@usp.br

    2000-07-01

    In a building project, several subsystems are designed, among them the air conditioning system. Electrical energy consumption profiles show that this subsystem is responsible for 40 to 50% of total consumption in a commercial building. Besides the study of technical aspects that should be considered in order to assure the thermal comfort of the occupants as well the temperature and humidity conditions for an efficient equipment operation, an economical evaluation of this subsystem should be also made. In retrofit projects, the economical aspect is also critical for such projects in order to assure bigger efficiency in an economically attractive way. This paper analyses some strategies that might be adopted in retrofitting an air conditioning system installed in a commercial building with mixed occupation. By mixed we mean that some floors have a typical office occupation profile and other floors are mainly occupied by electronic equipment. This analysis includes both technical and economical evaluation. The proposed solutions performance are compared to the old system, which allows to verify the retrofitting impact in energy consumption reduction and its economical feasibility. (author)

  9. Effect of air conditioning and chair cushion on scrotal temperature.

    Science.gov (United States)

    Song, Gook-Sup; Kim, Wonwoo; Seo, Ju Tae

    2008-08-01

    The hypothesis of this study is that the air conditioning temperature and thickness of the chair cushion affect a man's scrotal, and consequently testicular, temperature. Ten healthy male subjects volunteered for the study (age: 23.4 +/- 2.4 years; height: 173.8 +/- 5.09 cm; weight: 71.6 +/- 9.7 kg; body fat ratio: 18.6 +/- 4.1%). The air conditioning temperature was controlled at 18 degrees C to represent the heating season, and at 26 degrees C to represent the cooling season. The thickness of the chair cushions was varied from 0 to 8 cm at 2 cm intervals. The changes in the scrotal surface temperature (SST) and buttock skin temperature were measured for 120 min. At the ambient temperatures (t(a)) of 18 and 26 degrees C, the average SST were 33.76 +/- 1.28 and 35.02 +/- 0.54 degrees C for the chair cushion thickness (C(thk)) of 0 cm, 33.87 +/- 1.07 and 34.96 +/- 0.75 degrees C for C(thk) 2 cm, 33.91 +/- 0.84 and 35.03 +/- 0.85 degrees C for C(thk) 4 cm, 34.42 +/- 0.89 and 35.02 +/- 0.63 degrees C for C(thk) 6 cm, and 34.65 +/- 1.21 and 34.99 +/- 0.62 degrees C for C(thk) 8 cm respectively. SST was significantly affected by the air conditioning temperature (p < 0.001), but was not statistically correlated with the chair cushion thickness.

  10. SPECIAL ANALYSIS AIR PATHWAY MODELING OF E-AREA LOW-LEVEL WASTE FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Hiergesell, R.; Taylor, G.

    2011-08-30

    This Special Analysis (SA) was initiated to address a concern expressed by the Department of Energy's Low Level Waste Disposal Facility Federal Review Group (LFRG) Review Team during their review of the 2008 E-Area Performance Assessment (PA) (WSRC, 2008). Their concern was the potential for overlapping of atmospheric plumes, emanating from the soil surface above SRS LLW disposal facilities within the E-Area, to contribute to the dose received by a member of the public during the Institutional Control (IC) period. The implication of this concern was that the dose to the maximally-exposed individual (MEI) located at the SRS boundary might be underestimated during this time interval. To address this concern a re-analysis of the atmospheric pathway releases from E-Area was required. In the process of developing a new atmospheric release model (ARM) capable of addressing the LFRG plume overlap concern, it became obvious that new and better atmospheric pathway disposal limits should be developed for each of the E-Area disposal facilities using the new ARM. The scope of the SA was therefore expanded to include the generation of these new limits. The initial work conducted in this SA was to develop a new ARM using the GoldSim{reg_sign} program (GTG, 2009). The model simulates the subsurface vapor diffusion of volatile radionuclides as they release from E-Area disposal facility waste zones and migrate to the land surface. In the process of this work, many new features, including several new physical and chemical transport mechanisms, were incorporated into the model. One of the most important improvements was to incorporate a mechanism to partition volatile contaminants across the water-air interface within the partially saturated pore space of the engineered and natural materials through which vapor phase transport occurs. A second mechanism that was equally important was to incorporate a maximum concentration of 1.9E-07 Ci/m{sup 3} of {sup 14}CO{sub 2} in the air

  11. Proposal for energy saving in air conditioning equipment; Propuesta para ahorro energetico en acondicionadores de aire

    Energy Technology Data Exchange (ETDEWEB)

    Solis Recendez, Daniel H [Division de Ingenieria Electrica, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-10-15

    In the last decades, the air conditioning systems have become a crucial part in the search from comfort in extreme climates. Nevertheless, they have also become one of the greatest energy consumers. In this article it is proposed that the final conditions that the air conditioning equipment looks for not to be fixed, but variable in respect to a certain comfort zone. This zone is a variation of the used one in the bio-climatic chart of Olgyay that considers the rapidity whereupon the reached conditions tend to leave the comfort zone. It is analyzed how to choose the point on the zone that costs less energy in arriving to it. [Spanish] En las ultimas decadas, los sistemas de aire acondicionado se han vuelto una parte crucial en la busqueda de confort en climas extremosos. Sin embargo, tambien se han vuelto de los mayores consumidores de energia. En este articulo se propone que las condiciones finales que busquen lograr los acondicionadores no sean fijas, si no variables respecto a una determinada zona de confort. Dicha zona es una variacion de la utilizada en la carta bioclimatica de Olgyay, que considera la rapidez con que las condiciones alcanzadas tienden a abandonar la zona de confort. Se discute como elegir el punto sobre la zona que cueste menos energia en llegara el.

  12. Do-It-Yourself Additives Recharge Auto Air Conditioning

    Science.gov (United States)

    2010-01-01

    In planning for a return mission to the Moon, NASA aimed to improve the thermal control systems that keep astronauts comfortable and cool while inside a spacecraft. Goddard Space Flight Center awarded a Small Business Innovation Research (SBIR) contract to Mainstream Engineering Corporation, of Rockledge, Florida, to develop a chemical/mechanical heat pump. IDQ Inc., of Garland, Texas, exclusively licensed the technology and incorporates it into its line of Arctic Freeze products for automotive air conditioning applications. While working on the design, Mainstream Engineering came up with a unique liquid additive called QwikBoost to enhance the performance of the advanced heat pump design.

  13. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2001-01-01

    , even though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence......Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from Sick Building Syndrome (SBS) symptoms...... individual; individual control of the thermal environment should be provided. These principles of excellence are compatible with energy efficiency and sustainability....

  14. Simulation of Artificial Intelligence for Automotive Air-conditioning System

    Institute of Scientific and Technical Information of China (English)

    YUAN Xiao-mei; CHEN You-hua; CHEN Zhi-jiu

    2002-01-01

    The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small.

  15. Engine-driven hybrid air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    Chaokui QIN; Hongmei LU; Xiong LIU; Gerhard SCHMITZ

    2009-01-01

    A hybrid air-conditioning system that com-bines an engine-driven chiller with desiccant dehumidifi-cation was configured and experimentally tested to provide reliable data for energy consumption and operation cost. The engine performance and the desiccant wheel perfor-mance were measured and a numeric model previously set up for dehumidification capacity prediction was validated. For a reference building, the results based upon measured data show that under present electricity/gas price ratio, more than 40% of operation cost can be saved by the hybrid system.

  16. Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Tu Qiu, E-mail: tuqiuky@163.co [Guangzhou Institute of Energy Conversion, Chinese Academy of Science, Guangzhou 510640 (China) and Key Laboratory of Renewable Energy and Gas Hydrate, Chinese Academy of Science, Guangzhou 510640 (China); Mao Shoubo; Feng Yuhai; Guo Defang [Haier Air-Conditioning Electronic Co. Ltd., Qingdao 266510 (China)

    2011-07-15

    Highlights: {yields} A set of fresh air processor matched with VRF AC has been designed. {yields} The heating control model of variable condensation temperature target has been presented {yields} The control strategy can realize reliable running, high control accuracy and energy-saving. {yields} The control model is universal for fresh air processors with different capacities. -- Abstract: The fresh air processor (FAP), matched with the variable refrigerant flow air conditioning system (VRF AC), has been developed. Two control methods were adopted to control the system running and air outlet temperature, contrastively. The first method is that the running frequency in heating mode is adjusted in terms of the ordinary control method of VRF, i.e., constant condensation temperature. The experiment demonstrates the control method is not feasible. For nominal heating under different static pressure and defrosting under 200 Pa static pressure, the system fluctuates frequently. And for high temperature heating, the air outlet temperature far exceeds the target temperature. Furthermore, the control model of variable condensation temperature target has been presented, and the heat transfer correction factor is introduced into the control model. And the control parameters in the model are determined by experiment. The control model is universal for FAPs with different capacities by identifying and choosing the heat transfer correction factor in the control program. For low temperature heating, the method of switching rotation speed of the motor can be adopted to enhance air outlet temperature to 22 {sup o}C. The control strategy can provide guide for the design and application of FAP.

  17. Bioaerosol deposition on an air-conditioning cooling coil

    Science.gov (United States)

    Wu, Yan; Chen, Ailu; Luhung, Irvan; Gall, Elliott T.; Cao, Qingliang; Chang, Victor Wei-Chung; Nazaroff, William W.

    2016-11-01

    This study is concerned with the role of a fin-and-tube heat exchanger in modifying microbial indoor air quality. Specifically, depositional losses of ambient bioaerosols and particles onto dry (not cooled) and wet (cool) coil surfaces were measured for different airspeeds passing through the test coil. Total, bacterial and fungal DNA concentrations in condensate water produced by a wet coil were also quantified by means of fluorescent dsDNA-binding dye and qPCR assays. Results revealed that the deposition of bioaerosols and total particles is substantial on coil surfaces, especially when wet and cool. The average deposition fraction was 0.14 for total DNA, 0.18 for bacterial DNA and 0.22 for fungal DNA on the dry coil, increasing to 0.51 for total DNA, 0.50 for bacterial DNA and 0.68 for fungal DNA on the wet coil. Overall, as expected, deposition fractions increased with increasing particle size and increasing airspeed. Deposited DNA was removed from the cooling coil surfaces through the flow of condensing water at a rate comparable to the rate of direct deposition from air. A downward trend of bacterial and fungal DNA measured in condensate water over time provides suggestive evidence of biological growth on heat exchangers during nonoperational times of a ventilation system. This investigation provides new information about bioaerosol deposition onto a conventional fin-and-tube cooling coil, a potentially important factor influencing indoor exposure to microbial aerosols in air-conditioned buildings.

  18. An effective silencer design for artificially air conditioned environment.

    Science.gov (United States)

    Fujiwara, Kyoji; Pang, Li Feng

    2004-11-01

    An effective silencer for an air conditioning duct is studied. A duct with an acoustically soft boundary is employed as an effective silencer. On the acoustically soft boundary the sound pressure is zero and it is impossible to realize such boundary in the air-borne sound field, because of the non-existence of a much lighter medium than the air. In this study, the arrangement of one-quarter wave-length acoustic tubes is employed as a soft boundary. This acoustic tube has frequency dependence, but the sound pressure becomes nearly zero at the tube mouth around the odd resonance frequency. The relation between the noise reduction efficiency and this acoustically soft boundary is examined experimentally and more than 40 dB noise reduction is obtained in a one-half octave band around the first resonance frequency. It is also made clear that more than one wave length of soft boundary is required to get enough reduction compared with the reduction obtained in the case of quite a long soft boundary.

  19. Control of Computer Room Air Conditioning using IT Equipment Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Geoffrey C.; Storey, Bill; Patterson, Michael K.

    2009-09-30

    The goal of this demonstration was to show how sensors in IT equipment could be accessed and used to directly control computer room air conditioning. The data provided from the sensors is available on the IT network and the challenge for this project was to connect this information to the computer room air handler's control system. A control strategy was developed to enable separate control of the chilled water flow and the fans in the computer room air handlers. By using these existing sensors in the IT equipment, an additional control system is eliminated (or could be redundant) and optimal cooling can be provided saving significant energy. Using onboard server temperature sensors will yield significant energy reductions in data centers. Intel hosted the demonstration in its Santa Clara, CA data center. Intel collaborated with IBM, HP, Emerson, Wunderlich-Malec Engineers, FieldServer Technologies, and LBNL to install the necessary components and develop the new control scheme. LBNL also validated the results of the demonstration.

  20. Energy efficient air-conditioning technology for a healthier climate; Energieeffiziente Klimatechnik fuer ein gesundes Raumklima

    Energy Technology Data Exchange (ETDEWEB)

    Hartl, Thorsten [ebm-papst Motoren und Ventilatoren GmbH, St. Florian (Austria)

    2011-07-01

    Since climate and indoor air quality have a great impact on concentration, health and well being, it is important to provide good indoor air for example in classrooms. The use of air conditioning equipment enables an optimal air-conditioning, whether in new buildings or building alterations or renovations. Energy-saving EC fans in these air conditioning systems provide an efficient and quiet ventilation meeting the requirements. Thus, the contribution under consideration reports on centrifugal fans.

  1. Laboratory facility design and microbial indoor air quality in selected hospital laboratories.

    Science.gov (United States)

    Luksamijarulkul, Pipat; Kiennukul, Nuchanard; Vatthanasomboon, Pisit

    2014-05-01

    Hospital laboratory is one of workplace areas contaminated with a variety of biohazards. A cross sectional study was conducted to assess the microbial air quality and facility design in the laboratories of four selected governmental hospitals (Hospitals A, B, C, and D) in Bangkok, Thailand. One hundred eighty-eight indoor air samples were collected from 40 laboratory rooms to investigate bacterial and fungal counts using the Millipore air tester. Forty air samples were collected from the waiting areas of those laboratories, and 16 outdoor air samples were collected to use for comparison. Additionally, those laboratory facilities were assessed following biosafety facility design (10 items). Results indicated that the facility design of laboratory in the Hospital A met most of items of the biosafety facility criteria. The rest met only seven items of the criteria. Means +/- standard deviation (SD) of bacterial counts of 253.1 +/- 247.7 cfu/m3, 236.8 +/- 200.1 cfu/m3, 304.4 +/- 264.2 cfu/m3, and 146.7 +/- 127.0 cfu/m3, and fungal counts of 500.8 +/- 64.2 cfu/ m3, 425.0 +/- 21.2 cfu/m3, 357.0 +/- 121.2 cfu/m3, and 355.7 +/- 86.8 cfu/m3 were found in hospital laboratories A, B, C and D, respectively. The isolated colonies of bacteria and fungi were identified as group or genus. It was found that the most common bacteria was Staphylococcus spp (84.1%, 76.0%, 72.1% and 80.5%, respectively), whereas, the most common fungi were Aspergillus spp and septate hyphae fungi (42.0%, 37.5%, 39.5%, and 45.7%; vs 38.6%, 56.2%, 52.1%, and 37.2%, respectively). These data may be valuable to develop interventions to improve the microbial indoor air quality among hospital laboratories and for preventing the laboratory-acquired infections.

  2. Absorption and adsorption chillers applied to air conditioning systems

    Science.gov (United States)

    Kuczyńska, Agnieszka; Szaflik, Władysław

    2010-07-01

    This work presents an application possibility of sorption refrigerators driven by low temperature fluid for air conditioning of buildings. Thermodynamic models were formulated and absorption LiBr-water chiller with 10 kW cooling power as well as adsorption chiller with silica gel bed were investigated. Both of them are using water for desorption process with temperature Tdes = 80 °C. Coefficient of performance (COP) for both cooling cycles was analyzed in the same conditions of the driving heat source, cooling water Tc = 25 °C and temperature in evaporator Tevap = 5 °C. In this study, the computer software EES was used to investigate the performance of absorption heat pump system and its behaviour in configuration with geothermal heat source.

  3. MODELING THE AMBIENT CONDITION EFFECTS OF AN AIR-COOLED NATURAL CIRCULATION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Rui; Lisowski, Darius D.; Bucknor, Matthew; Kraus, Adam R.; Lv, Qiuping

    2017-07-02

    The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). One such variant, air-cooled RCCS, uses natural convection to drive the flow of air from outside the reactor building to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a half-scale model of the primary features of one conceptual air-cooled RCCS design. The facility was constructed to carry out highly instrumented experiments to study the performance of the RCCS concept for reactor decay heat removal that relies on natural convection cooling. Parallel modeling and simulation efforts were performed to support the design, operation, and analysis of the natural convection system. Throughout the testing program, strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under the same test procedures. Thus, significant analysis efforts were devoted to gaining a better understanding of these influences and the subsequent response of the NSTF to ambient conditions. It was determined that air humidity had negligible impacts on NSTF system performance and therefore did not warrant consideration in the models. However, temperature differences between the building exterior and interior air, along with the outside wind speed, were shown to be dominant factors. Combining the stack and wind effects together, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions. Some coefficients in the model were obtained based on best fitting the experimental data. The predictive capability of the empirical model was demonstrated by applying it to the new set of experimental data. The

  4. A method for targeting air samplers for facility monitoring in an urban environment

    Science.gov (United States)

    Bieringer, Paul E.; Longmore, Scott; Bieberbach, George; Rodriguez, Luna M.; Copeland, Jeff; Hannan, John

    2013-12-01

    There are a variety of applications that require the use of comprehensive specification of the weather conditions combined with an analysis that uses detailed modeling and simulation. The combination of these two elements can make it difficult to achieve the desired level of fidelity in a logistically feasible way. An example of this type of application is the deployment of surface-based sensors/samplers, which is a common practice for emission, and air quality monitoring purposes where the proper selection of sites for the measurement equipment is critical to an accurate characterization of the emissions. This is particularly true in urban environments where the limited availability of suitable sites and the non-intuitive dispersion patterns associated with the wind flow around the buildings and through the urban canyons make site selection difficult. This article demonstrates an improved methodology for optimally locating for air quality monitoring equipment within this complex and challenging environment. The methodology involves a) the utilization of a longer climatological record of meteorological observations or gridded reanalysis products to better represent the full range of representative meteorological conditions; b) reduction of the full climatological record into a subset of characteristic meteorological patterns and associated frequencies of occurrence, utilizing a multi-dimensional feature extraction and classification technique known as a Self Organizing Map (SOM); c) downscaling and diagnosis of the urban area building-aware wind flow fields for each characteristic meteorological pattern; d) atmospheric transport and dispersion (AT&D) simulations for each downscaled meteorological pattern, utilizing a building aware Lagrangian particle dispersion model; and finally e) the combination of predicted downwind concentrations/dosages for each meteorological pattern with their associated frequency of occurrence are used to generate Probability of Detection

  5. Assessment of workplace air concentrations of formaldehyde during and before working hours in medical facilities.

    Science.gov (United States)

    Higashikubo, Ichiro; Miyauchi, Hiroyuki; Yoshida, Satoru; Tanaka, Shinsuke; Matsuoka, Mitsunori; Arito, Heihachiro; Araki, Akihiro; Shimizu, Hidesuke; Sakurai, Haruhiko

    2017-04-07

    Workplace air concentrations of formaldehyde (FA) in medical facilities where FA and FA-treated organs were stored and handled were measured before and during working hours and assessed by the official method specified by Work Environment Measurement Law. Sixty-percent of the total facilities examined were judged as inappropriately controlled work environment. The concentrations of FA before working hours by spot sampling were found to exceed 0.1 ppm in some facilities, and tended to increase with increasing volume of containers storing FA and FA-treated materials. Regression analysis revealed that logarithmic concentrations of FA during working hours by the Law-specified analytical method were highly correlated with those before working hours by spot sampling, suggesting the importance for appropriate storing methods of FA and FA-treated materials. The concentrations of FA during working hours are considered to be lowered by effective ventilation of FA-contaminated workplace air and appropriate storage of FA and FA-treated materials in plastic containers in the medical facilities. In particular, such improvement by a local exhaust ventilation system and tightly-sealed containment of FA-treated material were urgently needed for the dissecting room where FA-treated cadavers were prepared and handled for a gross anatomy course in a medical school.

  6. Air quality investigations of the Sandia National Laboratories Sol se Mete Aerial Cable Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, W.M.; Silver, R.J. [New Mexico State Univ., Las Cruces, NM (United States). Physical Science Lab.

    1994-12-01

    The air quality implications of the test and evaluation activities at the Sandia National Laboratories Sol se Mete Aerial Cable Facility are examined. All facets of the activity that affect air quality are considered. Air contaminants produced directly include exhaust products of rocket motors used to accelerate test articles, dust and gas from chemical explosives, and exhaust gases from electricity generators in the test arenas. Air contaminants produced indirectly include fugitive dust and exhaust contaminants from vehicles used to transport personnel and material to the test area, and effluents produced by equipment used to heat the project buildings. Both the ongoing program and the proposed changes in the program are considered. Using a reliable estimate of th maximum annual testing level, the quantities of contaminants released by project activities ar computed either from known characteristics of test items or from EPA-approved emission factors Atmospheric concentrations of air contaminants are predicted using EPA dispersion models. The predicted quantities and concentrations are evaluated in relation to Federal, New Mexico, an Bernalillo County air quality regulations and the human health and safety standards of the American Conference of Governmental Industrial Hygienists.

  7. Neutral oxygen atom density in the MESOX air plasma solar furnace facility

    Science.gov (United States)

    Balat-Pichelin, Marianne; Vesel, Alenka

    2006-08-01

    The density of neutral oxygen atoms in the MESOX set-up, one device of the PROMES-CNRS solar facilities, was determined by a fiber-optics catalytic probe (FOCP). Plasma was created in a flowing air within a quartz tube with the outer diameter of 5 cm by a 2.45 GHz microwave generator with the output power up to 1000 W. The flow of air was varied between 4 and 20 l/h. The O-atom density was found to increase monotonously with the increasing discharge power, and it decreased with the increasing flow rate. The degree of dissociation of oxygen molecules in the plasma column depended largely on the flow rate. At the air flow of 4 l/h it was about 80% but it decreased to about 20% at the flow of 20 l/h.

  8. Neutral oxygen atom density in the MESOX air plasma solar furnace facility

    Energy Technology Data Exchange (ETDEWEB)

    Balat-Pichelin, Marianne [CNRS-PROMES, Laboratoire Procedes, Materiaux et Energie Solaire, UPR 8521, 7 rue du four solaire, F-66120 Font Romeu, Odeillo (France)], E-mail: balat@promes.cnrs.fr; Vesel, Alenka [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia)

    2006-08-21

    The density of neutral oxygen atoms in the MESOX set-up, one device of the PROMES-CNRS solar facilities, was determined by a fiber-optics catalytic probe (FOCP). Plasma was created in a flowing air within a quartz tube with the outer diameter of 5 cm by a 2.45 GHz microwave generator with the output power up to 1000 W. The flow of air was varied between 4 and 20 l/h. The O-atom density was found to increase monotonously with the increasing discharge power, and it decreased with the increasing flow rate. The degree of dissociation of oxygen molecules in the plasma column depended largely on the flow rate. At the air flow of 4 l/h it was about 80% but it decreased to about 20% at the flow of 20 l/h.

  9. Guideline to good practices for facility condition inspections at DOE nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This guide is intended to provide a means for owner/operators to have an awareness of the way business is actually being conducted on the shop floor. Also, this guide is intended to provide a means for maintenance managers to impart their expectations to crafts persons as to how maintenance should be conducted. It is expected that each DOE facility may use different approaches or methods than those defined in this guide. Explanation of the intent of this guide is provided in the Discussion section, and the specific guidelines that follow reflect generally accepted industry practices. In some cases, example situations accompany these guidelines. These examples have been provided only as an aid in clear understanding of the guidelines and should not be construed as the only method for meeting the intent of the guidelines. Therefore, deviation from any particular guideline would not, in itself, indicate a problem. If substantive differences exist between the intent of the Guideline and actual practice, management should evaluate current practice to determine the need to include/exclude proposed features. A change to maintenance practice would be appropriate if a performance weakness was determined to exist. Development, documentation, and implementation of other features which further enhance these guidelines for specific applications, is encouraged.

  10. Revealing the costs of air pollution from industrial facilities in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Holland, M. (EMRC, Brussels (Belgium)); Wagner, A.; Davies, T. (AEA Technology, Harwell (United Kingdom)); Spadaro, J. (SERC, Charlotte, NC (United States)); Adams, M. (EEA, Copenhagen (Denmark))

    2011-11-15

    This European Environment Agency (EEA) report assesses the damage costs to health and the environment resulting from pollutants emitted from industrial facilities. It is based on the latest information, namely for 2009, publicly available through the European Pollutant Release and Transfer Register (E-PRTR, 2011) in line with the United Nations Economic Commission for Europe (UNECE) Aarhus Convention regarding access to environmental information. This report investigates the use of a simplified modelling approach to quantify, in monetary terms, the damage costs caused by emissions of air pollutants from industrial facilities reported to the E-PRTR pollutant register. The approach is based on existing policy tools and methods, such as those developed under the EU's CAFE programme for the main air pollutants. This study also employs other existing models and approaches used to inform policymakers about the damage costs of pollutants. Together, the methods are used to estimate the impacts and associated economic damage caused by a number of pollutants emitted from industrial facilities, including: (1) ammonia (NH{sub 3}), nitrogen oxides (NO{sub x}), non-methane volatile organic compounds (NMVOCs), particulate matter (PM{sub 10}) and sulphur oxides (SO{sub x}); (2) heavy metals; (3) benzene, dioxins and furans, and polycyclic aromatic hydrocarbons (PAHs); (4) carbon dioxide (CO{sub 2}). The cost of damage caused by emissions from the E-PRTR industrial facilities in 2009 is estimated as being at least EUR 102-169 billion. A small number of industrial facilities cause the majority of the damage costs to health and the environment. Fifty per cent of the total damage cost occurs as a result of emissions from just 191 (or 2 %) of the approximately 10 000 facilities that reported at least some data for releases to air in 2009. Three quarters of the total damage costs are caused by the emissions of 622 facilities, which comprise 6 % of the total number. Of the

  11. Solar desiccant air-conditioning. Practical experience regarding operation and performance

    Energy Technology Data Exchange (ETDEWEB)

    Haller, A.; Trinkl, C.; Wittmann, R.; Zoerner, W. [Ingolstadt Univ. of Applied Sciences (Germany). Kompetenzzentrum Solartechnik; Hanby, V. [De Montfort Univ., Leicester (GB). Inst. of Energy and Sustainable Development (IESD)

    2007-07-01

    The Kompetenzzentrum Solartechnik of Ingolstadt University of Applied Sciences (Centre of Excellence for Solar Engineering) investigates the renewable-only based HVAC system of a multipurpose building. The 10.000 m{sup 2} gross floor area building is part of the biggest logistic-centre in the region serving the AUDI automobile production facilities. On the one hand, the investigation is supposed to demonstrate the potential of solar-assisted cooling, on the other hand, the monitoring, financed by the Bavarian Ministry of Environmental Affairs, focuses on the total energy balance of the building and the various innovative building technologies. Next to a ground source heat pump plant for base-load heating and cooling, the building is equipped with two arrays of solar-thermal flat-plate collectors (100 m{sup 2} of Conergy, Germany, and 180 m{sup 2} of Solahart, Australia) and a desiccant air-conditioning system (DEC, WOLF Anlagen-Technik, Germany). This consists of two plants with an air flow of 8.000 m{sup 3}/h and a nominal cooling capacity of 42 kW each. One of the two plants is monitored. The plant itself is considered a black box in a first approach, i.e. all incoming and outgoing energy flows and the air condition are measured. Apart from the investigation of the performance of the solar-assisted air-conditioning system, the feasibility of DEC-operation using flat-plate collectors available on the market is investigated. (orig.)

  12. 40 CFR 86.1832-01 - Optional equipment and air conditioning for test vehicles.

    Science.gov (United States)

    2010-07-01

    ... Optional equipment and air conditioning for test vehicles. For test vehicles selected under §§ 86.1822-01... be expected to influence emissions include, but are not limited to: air conditioning, power steering...) Except for air conditioning, where it is expected that 33 percent or less of a car line, within a test...

  13. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Science.gov (United States)

    2010-04-01

    ... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a) Outdoor.../or air conditioning equipment located outside the manufactured home, shall have permanently affixed, adjacent to the outlet, a metal tag which reads: This Connection Is for Air Conditioning Equipment Rated at...

  14. 40 CFR 86.162-03 - Approval of alternative air conditioning test simulations.

    Science.gov (United States)

    2010-07-01

    ... alternative air conditioning test simulations. (a) Upon petition from a manufacturer or upon the Agency's own initiative, the Administrator will approve a simulation of the environmental cell for air conditioning test... the tailpipe emissions, air conditioning compressor load, and fuel economy. (2) For any simulation...

  15. 40 CFR 86.166-12 - Method for calculating emissions due to air conditioning leakage.

    Science.gov (United States)

    2010-07-01

    ... to air conditioning leakage. 86.166-12 Section 86.166-12 Protection of Environment ENVIRONMENTAL... for calculating emissions due to air conditioning leakage. This section describes procedures used to determine a refrigerant leakage rate in grams per year from vehicle-based air conditioning units. The...

  16. Voltage controller design for air conditioning; Diseno de controlador de voltaje para aire acondicionado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Andrade, R; Lopez Villalobos, J.J; Valderrama Chairez, J; Ramirez, R.L. [Instituto Tecnologico de Nuevo Leon, Guadalupe, Nuevo Leon (Mexico)]. E-mails: roxana_garciaandrade@yahoo.com; xe2n@yahoo.com.mx; jose.valderrama@ieee.org

    2013-03-15

    This paper discusses the design of a voltage controller for an air conditioning system in order to generate additional power in activation or startup of the system, for which as a first stage is presented the modeling power generation of electric current through alternative means, such as solar energy. The results of this study will be the basis for development of the physical prototype of this system controller. [Spanish] El presente trabajo trata sobre el diseno de un controlador de voltaje para un sistema de aire acondicionado con el fin de generar energia adicional en la activacion o arranque de dicho sistema, para lo cual como primer fase se presenta el modelado de la generacion de corriente electrica mediante medios alternos, como lo es la energia solar. Los resultados de este trabajo seran la base para desarrollo del prototipo fisico de este sistema controlador.

  17. 8th International Symposium on Heating, Ventilation and Air Conditioning

    CERN Document Server

    Zhu, Yingxin; Li, Yuguo; Vol.1 Indoor and Outdoor Environment; Vol.2 HVAC&R Component and Energy System; Vol.3 Building Simulation and Information Management

    2014-01-01

    Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning is based on the 8th International Symposium of the same name (ISHVAC2013), which took place in Xi’an on October 19-21, 2013. The conference series was initiated at Tsinghua University in 1991 and has since become the premier international HVAC conference initiated in China, playing a significant part in the development of HVAC and indoor environmental research and industry around the world. This international conference provided an exclusive opportunity for policy-makers, designers, researchers, engineers and managers to share their experience. Considering the recent attention on building energy consumption and indoor environments, ISHVAC2013 provided a global platform for discussing recent research on and developments in different aspects of HVAC systems and components, with a focus on building energy consumption, energy efficiency and indoor environments. These categories span a broad range of topics, and the proce...

  18. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2002-01-01

    though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in buildings in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence......Air-conditioning of buildings has played a very positive role for economic development in warm climates. Still its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from SBS symptoms, even...... to the breathing zone of each individual; individual control of the airflow and/or the thermal environment should be provided. These principles of excellence should be combined with energy efficiency and sustainability of future buildings....

  19. Experimental Research on Liquid Desiccant Air-conditioning Unit

    Directory of Open Access Journals (Sweden)

    Feng Yueyan

    2016-01-01

    Full Text Available An experimental device of liquid desiccant air conditioning system is established. Experimental tests about the temperature difference between diluted solution of inlet and concentrated solution of exit in the solution heat exchanger are carried on, and CaCl2 solution is used as desiccant. Results show that: the fluctuation range in the day at different times of the basic difference of the measured temperature does not exceed 1°C, and the temperature difference between diluted solution of inlet and concentrated solution of exit in solution heat exchanger appears the minimum value of 2.7°C and the maximum value of 10.2°C. Also, the percent of the additional load and the ratio of additional load to the evaporator load are analyzed.

  20. Final work plan : indoor air and ambient air sampling near the former CCC/USDA grain storage facility in Everest, Kansas.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M. (Environmental Science Division)

    2010-05-24

    The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at the western edge of Everest, Kansas, from the early 1950s to the early 1970s. Sampling by the Kansas Department of Health and Environment (KDHE) in 1997 resulted in the detection of carbon tetrachloride in one domestic well (the Nigh well) northwest of the former facility. On behalf of the CCC/USDA, Argonne National Laboratory subsequently conducted a series of investigations to characterize the contamination (Argonne 2003, 2006a,b,c). Automatic, continuous monitoring of groundwater levels began in 2002 and is ongoing at six locations. The results have consistently indicated groundwater flow toward the north-northwest from the former CCC/USDA property to the Nigh property, then west-southwest from the Nigh property to the intermittent creek. Sitewide periodic groundwater and surface water sampling with analysis for volatile organic compounds (VOCs) began in 2008. Argonne's combined data indicate no significant downgradient extension of contamination since 2000. At present, the sampling is annual, as approved by the KDHE (2009) in response to a plan developed for the CCC/USDA (Argonne 2009). This document presents a plan for collecting indoor air samples in homes located along and adjacent to the defined extent of the carbon tetrachloride contamination. The plan was requested by the KDHE. Ambient air samples to represent the conditions along this pathway will also be taken. The purpose of the proposed work is to satisfy KDHE requirements and to collect additional data for assessing the risk to human health due to the potential upward migration of carbon tetrachloride and its primary degradation product (chloroform) into homes located in close proximity to the former grain storage facility, as well as along and within 100 ft laterally from the currently defined plume emanating from the former Everest facility. Investigation of the indoor air

  1. CFD SIMULATION OF AIR ION REGIME IN WORK AREAS AT CONDITION OF ARTIFICIAL AIR IONIZATION

    Directory of Open Access Journals (Sweden)

    M. M. Biliaiev

    2016-02-01

    sources and ions of different polarity; physical processes affecting the formation of ions concentration field. Practical value. The obtained 2D CFD model for calculating the air ions regime in working areas allow to calculate the concentration of ions at the location of the respiratory organs, taking into account the basic physical factors determining the formation of ions concentration fields. It will allow rationally arranged the ionizers in the working premises to create the comfortable working conditions for staff.

  2. Automobile air-conditioning. Its energy and environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-05-01

    Over the last three decades, automobile manufacturers have made a lot of progress in specific fuel consumption and engine emissions of pollutants. Yet the impact of these improvements on vehicle consumption has been limited by increased dynamic performances (maximum speed, torque), increased safety (power steering and power brakes) and increased comfort (noise and vibration reduction, electric windows and thermal comfort). Because of this, the real CO{sub 2}-emission levels in vehicles is still high in a context where road transport is a major factor in the balance sheet of greenhouse gas emissions, thus in complying with the international climate convention. Although European, Japanese and Korean manufacturers signed an important agreement with the European Commission for voluntarily reducing CO{sub 2} emissions from their vehicles, with a weighted average emission goal by sales of 140 grams per km on the MVEG approval cycle by 2008, it has to be noted that the European procedures for measuring fuel consumption and CO{sub 2} emissions do not take accessories into account, especially air-conditioning (A/C). The big dissemination of this equipment-recognized as a big energy consumer and as using a refrigerant with a high global warming potential-led ADEME to implement a set of assessments of A/C's energy and environmental impact. In particular these assessments include studies of vehicle equipment rates, analyses of impact on fuel consumption as well as regulated pollutant emissions in the exhaust, a characterization of the refrigerant leakage levels and an estimate of greenhouse gas emissions for all air-conditioned vehicles. This leaflet summarizes the results of these actions. (author)

  3. Characterization of 41Ar production in air at a PET cyclotron facility

    Science.gov (United States)

    Cicoria, Gianfranco; Cesarini, Francesco; Infantino, Angelo; Vichi, Sara; Zagni, Federico; Marengo, Mario

    2017-06-01

    In the production of Positron Emission Tomography (PET) nuclides at a medical cyclotron facility 41Ar (T1/2 = 109.34 m) is produced by the activation of air due to the neutron flux, according to the 40Ar(n, γ)41Ar reaction. In this work, we describe a relatively inexpensive and readily reproducible methodology of air sampling that can be used for quantification of 41Ar during the routine production of PET nuclides. We report the results of an extensive measurement campaign in the cyclotron bunker and in the ducts of the ventilation system, before and after final filtering of the extracted air. Air Samples were analyzed using a gamma-ray spectrometry system equipped with HPGe detector, with proper correction of the efficiency calibration to account for the samples density. The results of measurement were then used to evaluate the Total Effective Dose (TED) to the population living in the surrounding areas, due to routine emissions in the operation of the cyclotron. The average 41Ar saturation yield per one liter of air emitted in the environment resulted to be (0.044 ± 0.007) Bq/(μA ṡ dm3). The maximum value of TED for the critical group of the population, even considering an overestimated workload, was less than 0.19 μSv/year, well below the level of radiological relevance.

  4. Characterization of microbial communities in exhaust air treatment systems of large-scale pig housing facilities.

    Science.gov (United States)

    Haneke, J; Lee, N M; Gaul, T W; Van den Weghe, H F A

    2010-01-01

    Exhaust air treatment has gained importance as an essential factor in intensive livestock areas due to the rising emissions in the environment. Wet filter walls of multi-stage exhaust air treatment systems precipitate gaseous ammonia and dust particles from exhaust air in washing water. Microbial communities in the biomass developed in the washing water of five large-scale exhaust air treatment units of pig housing facilities, were investigated by fluorescence in situ hybridization (FISH) and 16S rDNA sequence analyses. No "standard" nitrifying bacteria were found in the washing water. Instead mainly α-Proteobacteria, aggregating β- and χ-Proteobacteria, a large number of Actinobacteria, as well as individual Planctomycetales and Crenarchaeota were detected after more than twelve months' operation. The main Proteobacteria species present were affiliated to the families Alcaligenaceae, Comamonadaceae and Xanthomonadaceae. Furthermore, we investigated the consumption of inorganic nitrogen compounds in the washing water of one exhaust air treatment unit during a fattening period with and without pH control. Maintaining the pH at 6.0 resulted in a ca. fivefold higher ammonium concentration and a ca. fourfold lower concentration of oxidized nitrogen compounds after the fattening period was finished.

  5. Development of a non-radiological air emissions inventory for a nuclear industrial facility

    Energy Technology Data Exchange (ETDEWEB)

    Patnoe, C.A.; Porter, G.V.; Almquist, R.S.

    1991-01-01

    This paper describes the major issues that impacted the organization and structure of a project for developing a comprehensive non- radiological air emissions inventory for a nuclear weapons facility. The major issues addressed paralleled the development of the inventory project and fall into the following categories: (1) defining the scope of work, (2) developing and managing the air emission inventory project, and (3) field investigations and evaluating operations for air emissions. This paper also describes the lines of communication that were established with state regulators to resolve problems and develop a successful working relationship. This paper illustrates a means to complete a complex air emission inventory with proper organization and cooperation with regulatory agencies. Further, it indicates the need of critical evaluation of project tasks to evaluate their impact on project schedule; it provides a method for implementing a quality assurance program that audits all phases of the emission survey; and it demonstrates a way of effectively managing outside contractors to meet schedule requirements and assure a high quality product. This paper is of value to those undertaking a similar complex air emission survey. 2 refs.

  6. Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers

    Directory of Open Access Journals (Sweden)

    Kalenik Marek

    2015-03-01

    Full Text Available Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers. The paper presents the analysis of results of the investigations concerning the influence of various constructive solutions of the air-water mixers on hydraulic operating conditions of the air lift pump. The scope of the investigations encompassed the determination of characteristics of delivery head and delivery rate for three types of air-water mixers applied in the constructed air lift pump. Using the obtained results, the efficiency of the three types of air-water mixers applied in this air lift pump was determined. The analysis was carried out and there was checked whether the improved analytical Stenning-Martin model can be used to design air lift pumps with the air-water mixers of these types. The highest capacity in the water transport was reached by the air lift pump with the 1st type air-water mixer, the lowest one – with the 3rd type air-water mixer. The water flow in the air lift pump increases along with the rise in the air flow. The lower are the hydraulic losses generated during flow of the air flux by the air-water mixer, the higher is the air lift pump capacity. Along with the rise in the water delivery head, the capacity of the air lift pump decreases. The highest efficiency is reached by the air lift pump with the 1st type air-water mixer, the lowest – with the 3st type air-water mixer. The efficiency of the air lift pump for the three investigated types of air-water mixers decreases along with the rise in air flow rate and water delivery head. The values of submergence ratio (h/L of the delivery pipe, calculated with the use of the improved analytical Stenning-Martin model, coincide quite well with the values of h/L determined from the measurements.

  7. Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

    2006-01-01

    Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e

  8. Defense Facility Condition: Revised Guidance Needed to Improve Oversight of Assessments and Ratings

    Science.gov (United States)

    2016-06-01

    showed us a classroom inside of a hangar where mold had been found on picture frames, wall shelves, and desk items (see figure 5). Figure 5: Desk...Under Secretary of Defense for Acquisition, Technology , and Logistics Memorandum, Standardizing Facility Condition Assessments (Sept. 10, 2013). 7The...Under Secretary of Defense for Acquisition, Technology , and Logistics Memorandum, Facility Sustainment and Recapitalization Policy (Apr. 29, 2014

  9. Desiccant dehumidification in decentralized air conditioning systems; Einsatz der Sorptionstechnik in der dezentralen Klimatisierung von Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Busweiler, Ulrich [Fachhochschule Giessen-Friedberg (Germany)

    2009-01-15

    Dehumidification of supply air with adsorption wheels, which is known from desiccant cooling systems, is now applied to small air handling units which condition the air of one single room. There is an increase in comfort in winter by recovery of moisture. In summer, dehumidification and cooling of air are ensured by an absolutely dry process without any hygienic risk. (orig.)

  10. Study on the design schemes of the air-conditioning system in a gymnasium

    Science.gov (United States)

    Zhang, Yujin; Wu, Xinwei; Zhang, Jing; Pan, Zhixin

    2017-08-01

    In view of designing the air conditioning project for a gymnasium successfully, the cooling and heating source schemes are fully studied by analyzing the surrounding environment and energy conditions of the project, as well as the analysis of the initial investment and operating costs, which indicates the air source heat pump air conditioning system is the best choice for the project. The indoor air conditioning schemes are also studied systematically and the optimization of air conditioning schemes is carried out in each area. The principle of operating conditions for the whole year is followed and the quality of indoor air and energy-saving are ensured by the optimized design schemes, which provide references for the air conditioning system design in the same kinds of building.

  11. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1999-01-01

    : better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; small amounts of clean air should be served gently, close to the breathing zone of each individual; individual...

  12. Influence of the inlet air in efficiency of photocatalytic devices for mineralization of VOCs in air-conditioning installations.

    Science.gov (United States)

    Jimenez-Relinque, E; Castellote, M

    2014-10-01

    Nowadays, a large proportion of photocatalytic oxidation (PCO) devices are being implemented in heating, ventilation and air-conditioning systems. However, no systematic studies have been carried out regarding the influence of inlet air preconditioning. To analyse the impact of the inlet air-conditions into photocatalytic efficiency, a simulated air-conditioning duct with flowing gas through inside was designed. Isobutylene was chosen as the target VOCs. The concentration in the gas phase was monitored using a photoionization detector. The influence of flow rate, relative humidity and temperature on the VOC removal efficiency was analysed. Experimental results were presented in terms of gas-removal efficiency (η) and clean air delivery rate (CADR) and analysed on a kinetic basis. From them, the weight of each parameter in the global process has been determined, from bigger to smaller contribution, flow>temperature>relative humidity. Also, the relevance of the inlet air conditions has been illustrated in a model room in order to determinate the time necessary to obtain a threshold value accomplishing with enough air quality and the energy consumption of the device. Additionally, the photocatalytic decontamination has been assimilated to the "air exchange rate", a parameter commonly used in indoor air quality studies. The results show that preconditioning of air can improve the efficiency of photocatalytic devices and bring important energy savings.

  13. Intraoral air pressure and oral air flow under different bleed and bite-block conditions.

    Science.gov (United States)

    Putnam, A H; Shelton, R L; Kastner, C U

    1986-03-01

    Intraoral pressures and oral flows were measured as normal talkers produced /p lambda/ and /si/ under experimental conditions that perturbed the usual aeromechanical production characteristics of the consonants. A translabial pressure-release device was used to bleed off intraoral pressure during /p/. Bite-blocks were used to open the anterior bite artificially during /s/. For /p/, intraoral pressure decreased and translabial air leakage increased as bleed orifice area increased. For /s/, flow increased as the area of sibilant constriction increased, but differential pressure across the /s/ oral constriction did not vary systematically with changes in its area. Flow on postconsonantal vowels /lambda/ and /i/ did not vary systematically across experimental conditions. The data imply that maintenance of perturbed intraoral pressure was more effective when compensatory options included opportunity for increased respiratory drive and structural adjustments at the place of consonant articulation rather than increased respiratory drive alone.

  14. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-12-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof-mounted photovoltaic modules. The modules are fixed on special cradles which fold at night to expose the roof to the night sky, thereby enhancing night-time cooling, which is substantial in the desert environment. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. Application to a typical Middle-Eastern desert site reveals that indeed such a design is feasible with present-day technology; and should be even more attractive with future advances in technology. © 2011 Copyright Taylor and Francis Group, LLC.

  15. Neutron imaging of diabatic two-phase flows relevant to air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Geoghegan, Patrick J [ORNL; Sharma, Vishaldeep [ORNL

    2017-01-01

    The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

  16. TNO HVAC facilities

    NARCIS (Netherlands)

    Hammink, H.A.J.

    2015-01-01

    TNO has extensive knowledge of heating, ventilation and air conditioning (HVAC), and can offer its services through theoretical studies, laboratory experiments and field measurements. This complete scope, made possible through our test facilities, enables the effective development of new products,

  17. Air quality modelling as a tool used in selecting technological alternatives for developing a new abrasive facility

    Directory of Open Access Journals (Sweden)

    Radu Mihăiescu

    2011-08-01

    Full Text Available Production of abrasive compounds employs the use of various organic materials as adhesivesor as conditioners. During the baking process, a significant amount of air pollutant substances, includingvarious forms of organic compounds are emitted in the atmosphere. Selecting the most suitabletechnological process is a procedure that involves a cost benefit analysis as well as procedures forcomplying with BAT requirements (best available techniques. Assessing the resulting environmentquality in the vicinity of a new facility is also important, IPPC Directive clearly specifies that a new facilitymust not induce changes of the quality of the environment. This is highly dependent on localmeteorological and topographical conditions. The ISCST3 model was applied to assess the atmosphericdispersions associated with several potential technological designs, and compare their impacts on theenvironment.

  18. [Bipolar ionisation of indoor air through ion generators mountable into inflow ventilation and conditioning].

    Science.gov (United States)

    Dudarev, A A; Spichkin, G L; Denisikhina, D M; Burtsev, S I

    2010-01-01

    Experimental studies and digital modelling of artificial indoor air ionisation through bipolar ionisers mountable into inflow ventilation and conditioning proved possible creation of continuous even bipolar ion background in indoor air, similar to the natural one.

  19. Application of Computer Model to Estimate the Consistency of Air Conditioning Systems Engineering

    Directory of Open Access Journals (Sweden)

    Amal El-Berry

    2013-04-01

    Full Text Available Reliability engineering is utilized to predict the performance and optimization of the design and maintenance of air conditioning systems. There are a number of failures associated with the conditioning systems. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely are mainly due to a variety of problems with one or more components of an air conditioner or air conditioning system. To maintain the system forecasting for system failure rates are very important. The focus of this paper is the reliability of the air conditioning systems. The most common applied statistical distributions in reliability settings are the standard (2 parameter Weibull and Gamma distributions. Reliability estimations and predictions are used to evaluate, when the estimation of distributionsparameters is done. To estimate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several companies’ departments is checked. This air conditioning system is divided into two systems, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40 - 45oF (4 - 7oC. The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, with the application of the Weibull and Gamma distributions it is indicated that the reliability for the systems equal to 86.012% and 77.7% respectively . A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families is studied. It is found that Weibull method has performed well for decision making .

  20. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    H. Mirinejad

    2008-01-01

    Full Text Available Problem statement: Heating, Ventilating and Air Conditioning (HVAC systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort field is introduced, followed by a review and comparison of the main existing control techniques used in HVAC systems to date. Results: The present overview shows that intelligent controllers which are based on the human sensation of thermal comfort have a better performance in providing thermal comfort as well as energy saving than the traditional controllers and those based on a model of the HVAC system. Conclusion: Such an overview provides an insight into current control methods in HVAC systems and can help scholars and HVAC learners to have the comprehensive information about a variety of control techniques in the field of HVAC and therefore to better design a proper controller for their work

  1. Assessing summertime urban air conditioning consumption in a semiarid environment

    Science.gov (United States)

    Salamanca, F.; Georgescu, M.; Mahalov, A.; Moustaoui, M.; Wang, M.; Svoma, B. M.

    2013-09-01

    Evaluation of built environment energy demand is necessary in light of global projections of urban expansion. Of particular concern are rapidly expanding urban areas in environments where consumption requirements for cooling are excessive. Here, we simulate urban air conditioning (AC) electric consumption for several extreme heat events during summertime over a semiarid metropolitan area with the Weather Research and Forecasting (WRF) model coupled to a multilayer building energy scheme. Observed total load values obtained from an electric utility company were split into two parts, one linked to meteorology (i.e., AC consumption) which was compared to WRF simulations, and another to human behavior. WRF-simulated non-dimensional AC consumption profiles compared favorably to diurnal observations in terms of both amplitude and timing. The hourly ratio of AC to total electricity consumption accounted for ˜53% of diurnally averaged total electric demand, ranging from ˜35% during early morning to ˜65% during evening hours. Our work highlights the importance of modeling AC electricity consumption and its role for the sustainable planning of future urban energy needs. Finally, the methodology presented in this article establishes a new energy consumption-modeling framework that can be applied to any urban environment where the use of AC systems is prevalent.

  2. Multivariate analysis comparing microbial air content of an air-conditioned building and a naturally ventilated building over one year

    Science.gov (United States)

    Parat, Sylvie; Perdrix, Alain; Fricker-Hidalgo, Hélène; Saude, Isabelle; Grillot, Renee; Baconnier, Pierre

    Heating, ventilation and air-conditioning (HVAC) may be responsible for the production and spread of airborne microorganisms in office buildings. In order to compare airborne microbiological flora in an air-conditioned building with that in a naturally ventilated building, eight sets of measurements were made over a 1-year period. Concurrently with other environmental measurements, air samples were collected in each building, from three offices and from the outdoor air, using the Andersen single-stage sampler. Three different media were used to culture fungi, staphylococci and mesophilic bacteria. Multivariate analysis revealed a group of offices more contaminated than others, and a marked seasonal variation in fungal concentrations. A comparison of mean levels of microorganisms measured in the two buildings showed that the air microbial content was significantly higher and more variable in the naturally ventilated building than in the air-conditioned building. Moreover, in the naturally ventilated building, the interior fungal content was strongly dependent on the outdoor content, while in the air-conditioned building fungal concentrations remained constant despite significant variations measured outside. This was confirmed by a statistical comparison of the correlation coefficients between indoor and outdoor concentrations. No difference was observed regarding gaseous pollutants and temperature, but relative humidity was significantly higher in the air-conditioned building. The effect of HVAC was to prevent the intake of outdoor particles and to dilute the indoor concentrations. These results are consistent with the presence of high-efficiency filters and a steam humidifier in the HVAC system under study.

  3. Arduino-based control system for measuring ammonia in air using conditionally-deployed diffusive samplers

    Science.gov (United States)

    Ham, J. M.; Williams, C.; Shonkwiler, K. B.

    2012-12-01

    Arduino microcontrollers, wireless modules, and other low-cost hardware were used to develop a new type of air sampler for monitoring ammonia at strong areal sources like dairies, cattle feedlots, and waste treatment facilities. Ammonia was sampled at multiple locations on the periphery of an operation using Radiello diffusive passive samplers (Cod. RAD168- and RAD1201-Sigma-Aldrich). However, the samplers were not continuously exposed to the air. Instead, each sampling station included two diffusive samplers housed in specialized tubes that sealed the cartridges from the atmosphere. If a user-defined set of wind and weather conditions were met, the Radiellos were deployed into the air using a micro linear actuator. Each station was solar-powered and controlled by Arduinos that were linked to a central weather station using Xbee wireless modules (Digi International Inc.). The Arduinos also measured the total time of exposure using hall-effect sensors to verify the position of the cartridge (i.e., deployed or retracted). The decision to expose or retract the samplers was made every five minutes based on wind direction, wind speed, and time of day. Typically, the diffusive samplers were replaced with fresh cartridges every two weeks and the used samplers were analyzed in the laboratory using ion chromatography. Initial studies were conducted at a commercial dairy in northern Colorado. Ammonia emissions along the Front Range of Colorado can be transported into the mountains where atmospheric deposition of nitrogen can impact alpine ecosystems. Therefore, low-cost air quality monitoring equipment is needed that can be widely deployed in the region. Initial work at the dairy showed that ammonia concentrations ranged between 600 to 1200 ppb during the summer; the highest concentrations were downwind of a large anaerobic lagoon. Time-averaged ammonia concentrations were also used to approximate emissions using inverse dispersion models. This methodology provides a

  4. Experimental investigation of integrated air purifying technology for bioaerosol removal and inactivation in central air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    ZHENG Xiaohong; LIU Hongmin; YE Xiaojiang; LI Kejun; WANG Ruzhu; ZHAO Liping; Lisa. X. Xu; CHEN Yazhu; JIN Xinqiao; GU Bo; BAI Jingfeng

    2004-01-01

    In this research, high voltage static electricity and ultraviolet technologies were integrated to an air purifying device which can be used to trap and kill airborne bacteria and viruses in central air-conditioning systems. An experimental platform was built to mimic the central air system, in which the efficacy of the newly built device was examined. In addition to the standard physical and chemical tests, bacteriophages were used to simulate airborne viruses in the experimental system. The bacteriophage suspension was aerosolized into the air with ultrasonic wave atomization. The result showed that more than 86% removal efficiency of micro-particles (<10 micron in diameter) were removed after the device was in operation in a building and more than 95% of bacteriophages in the experimental system. It is concluded that the integrated air purifier is suitable for controlling air quality and preventing virus transmission through the central air system.

  5. Rational utilization of energy applications in the facility management. Energy efficient system technologies of the ventilation technology, air conditioning technology, refrigeration technology and lighting technology. Plant concepts, applications and practical tips; Rationelle Energieanwendungen in der Gebaeudetechnik. Energieeffiziente Systemtechnologien der Raumluft-, Klima-, Kaelte-, und Beleuchtungstechnik. Anlagenkonzepte, Anwendungen, Praxistipps

    Energy Technology Data Exchange (ETDEWEB)

    Theiss, Eric

    2012-11-01

    Due to increasing energy prices and increasingly scarce resources, existing energy-intensive systems of the ventilation technology, air conditioning technology, refrigeration technology as well as lighting technology have to be reconsidered. Innovative approaches have to be developed. Under this aspect, the author of the book under consideration describes functional principles and variants of utilization as well as innovations and prototypes in this area. The optimisation of the energy efficiency and the increase of the user comfort are illustrated by means of the building automation. With respect to the actual regulations, the characteristic parameters are examined. Economic feasibility studies are performed. By way of illustration, possible system integrations are described on the basis of example plants and object descriptions. The author of this book also presents a glossary and the most important contact addresses. The book under consideration is an ideal advisor for architects, building owners, investors, specialist engineers, energy consultants and students.

  6. Novel compact sorption generators for car air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Tamainot-Telto, Z.; Metcalf, S.J.; Critoph, R.E. [School of Engineering, University of Warwick, Gibet Hill Road, Coventry CV4 7AL (United Kingdom)

    2009-06-15

    A prototype compact generator using the activated carbon-ammonia pair based on the plate heat exchanger concept has been designed and built at Warwick University. The novel generator has low thermal mass and good heat transfer. The heat exchanger uses nickel-brazed shims and spacers to create adsorbent layers only 4 mm thick between pairs of liquid flow channels of very low thermal mass. The prototype sorption generator manufactured was evaluated under EU car air conditioning test conditions. The prototype sorption generator is described and its experimental performance reported. While driven with waste heat from the engine coolant water (at 90 C), a pair of the current prototype generators (loaded with about 1 kg of activated carbon) operating out of phase has produced an average cooling power 1.6 kW with about 2 kW peaks. The typical average COP obtained is 0.22. (author) [French] Un prototype du generateur compact, base sur le concept des echangeurs de chaleur a plaques et utilisant la paire charbon actif-ammoniac, a ete concu et construit a l'Universite de Warwick. Le nouveau generateur a une faible inertie thermique et un excellent transfert de chaleur. L' echangeur utilise des plaques ayant des micro-canaux et des intercalaires brases au Nickel pour creer des couches d'adsorbant de 4 mm d'epaisseur entre les paires de plaques a l'interieur desquelles circule le fluide liquide. Le prototype du generateur a sorption ainsi fabrique a ete teste suivant des conditions prescrites par la Norme Europeenne de la Climatisation Automobile. Le prototype du generateur a sorption est decrit et ses performances experimentales presentees. Une paire dudit prototype (contenant chacun 1 kg the charbon actif), operant avec dephasage et ulisant des pertes thermiques en provenance de l'eau de refroidissement de moteur (a 90 C), a produit une puissance frigorifique moyenne de 1.6 kW avec une valeur maximum de 2 kW. La valeur typique du COP moyen est de

  7. Analysis of air-conditioning and drying processes using spreadsheet add-in for psychrometric data

    Directory of Open Access Journals (Sweden)

    E.O. Diemuodeke

    2010-01-01

    Full Text Available A spreadsheet add-in for the psychrometric data at any barometric pressure and in the air-conditioning and drying temperatureranges was developed using appropriate correlations. It was then used to simulate and analyse air-conditioning and dryingprocesses in the Microsoft Excel environment by exploiting its spreadsheet and graphic potentials. The package allowsone to determine the properties of humid air at any desired state, and to simulate and analyse air-conditioning as well asdrying processes. This, as a teaching tool, evokes the intellectual curiosity of students and enhances their interest and abilityin the thermodynamics of humid-air processes.

  8. Does urban vegetation mitigate air pollution in northern conditions?

    Science.gov (United States)

    Setälä, Heikki; Viippola, Viljami; Rantalainen, Anna-Lea; Pennanen, Arto; Yli-Pelkonen, Vesa

    2013-12-01

    It is generally accepted that urban vegetation improves air quality and thereby enhances the well-being of citizens. However, empirical evidence on the potential of urban trees to mitigate air pollution is meager, particularly in northern climates with a short growing season. We studied the ability of urban park/forest vegetation to remove air pollutants (NO2, anthropogenic VOCs and particle deposition) using passive samplers in two Finnish cities. Concentrations of each pollutant in August (summer; leaf-period) and March (winter, leaf-free period) were slightly but often insignificantly lower under tree canopies than in adjacent open areas, suggesting that the role of foliage in removing air pollutants is insignificant. Furthermore, vegetation-related environmental variables (canopy closure, number and size of trees, density of understorey vegetation) did not explain the variation in pollution concentrations. Our results suggest that the ability of urban vegetation to remove air pollutants is minor in northern climates.

  9. 33 CFR 126.15 - What conditions must a designated waterfront facility meet?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What conditions must a designated waterfront facility meet? 126.15 Section 126.15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... safe storage; and kept clean and free of scrap materials, empty containers, soiled wiping rags,...

  10. A PROBABILISTIC INVENTORY MODEL FOR CONDITIONAL CREDIT PERIOD AND LEAD TIME WITH MULTIPLE STORAGE FACILITIES

    Directory of Open Access Journals (Sweden)

    S. S. Mishra

    2008-01-01

    Full Text Available A probabilistic inventory model for conditional credit period with exponential demand, non-zero lead time and multiple storage facility has been developed. The behaviour of total expected cost (TEC has been examined and the use and application of the model is demonstrated with the help of a numerical example.

  11. Measurement of basic thermal-hydraulic characteristics under the test facility and reactor conditions

    Energy Technology Data Exchange (ETDEWEB)

    Eduard A Boltenko; Victor P Sharov [Elektrogorsk Research and Engineering Center, EREC, Bezimyannaja Street, 6, Elektrogorsk, Moscow Region, 142530 (Russian Federation); Dmitriy E Boltenko [State Scientific Center of Russian Federation IPPE, Bondarenko Square, Obhinsk, Kaluga Region, 249020 (Russian Federation)

    2005-07-01

    Full text of publication follows: The nuclear power of Russia is based on the reactors of two types: water-water - WWER and uranium - graphite channel RBMK. The nuclear power development is possible with performance of the basic condition - level of nuclear power plants (NPP) safety should satisfy the rigid requirements. The calculated proof of NPPs safety made by means of thermal-hydraulic codes of improved estimation, verified on experimental data is the characteristic of this level. The data for code verification can be obtained at the integral facilities simulating a circulation circuit of NPP with the basic units and intended for investigation of circuit behaviour in transient and accident conditions. For verification of mathematical models in transient and accident conditions, development of physically reasonable methods for definition of the various characteristics of two-phase flow the experimental data, as the integrated characteristics of a flow, and data on the local characteristics and structure of a flow is necessary. For safety assurance of NPP it is necessary to monitor and determine the basic thermalhydraulic characteristics of reactor facility (RF). It is possible to refer coolant flow-rate, core input and output water temperature, heat-power. The description of the EREC works in the field completion and adaptation of certain methods with reference to measurements in dynamic modes of test facility conditions and development of methods for measurements of basic thermal-hydraulic characteristics of reactor facilities is presented in the paper. (authors)

  12. Air mycopopulations in Petrovská klobása producing facility

    Directory of Open Access Journals (Sweden)

    Škrinjar Marija M.

    2011-01-01

    Full Text Available Different types of filamentous fungi periodically cause problems in small-scale facilities for traditional dry fermented sausages, such as Petrovská klobása from Vojvodina province (Serbia. Mould contamination can be observed during processing, ripening, and storage. Sausages may become spoiled due to visible mould colonies on the surface and off-flavours they produce. The most important - if mycotoxin production occurs it might promote a number of health disorders. Knowledge and control of filamentous fungi are, therefore, essential to produce sausages that satisfy the criteria of hygienic quality, sensorial characteristics, and food safety. The aim of this study was to survey mycoflora of a small-scale facility producing traditional dry fermented sausage - Petrovská klobása. The mould contamination of the air in processing unit and ripening chambers was investigated, in order to determine the important fungi in terms of spoilage of the products and ability to produce mycotoxins. The mould contamination of air in processing unit and ripening chambers examined was in range 0.22 - 1.89 log CFU/P.d. Isolated moulds belong to 6 genera: Aspergillus (3 species, Cladosporium (1 species, Eurotium (2 species, Fusarium (1 species, Penicillium (12 species and Scopulariopsis (1 species. The most abundant were species of Penicillium genus, many of which are capable for mycotoxin production. The level and diversity of fungal contamination of air varied between samples, influenced by the general hygiene, the buildings, the airflow, the outdoor environments, and the time of year. This knowledge is crucial for the improvement of hygiene control systems in small-scale processing units.

  13. Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation

    Directory of Open Access Journals (Sweden)

    Haslinda Mohamed Kamar

    2012-03-01

    Full Text Available A semi-empirical model for simulating thermal and energy performance of an automotive air-conditioning (AAC system in passenger vehicles has been developed. The model consists of two sections, namely empirical evaporator correlations and dynamic load simulation. The correlations used consider sensible and latent heat transfer performance of the evaporator coil. The correlations were obtained from the experimental data of actual air conditioning system for a compact size passenger car. The sensible heat transfer correlation relates the evaporator air off dry-bulb temperature to inlet air dry-bulb temperature, humidity ratio, evaporator air velocity, condenser inlet air dry-bulb temperature, condenser air velocity and compressor speed. The latent heat transfer correlation relates the coil air-off humidity ratio to the same six independent variables. The dynamic load simulation model was developed based on the z-transfer function method with a one-minute time step. The cooling load calculations were performed using heat gain weighting factors. Heat extraction rate and cabin air dry-bulb temperature calculations were carried out using air temperature weighting factors. The empirical evaporator sensible and latent heat transfer correlations were embedded in the loads calculation program to enable the determination of evaporator inlet and outlet air conditions, the cabin air temperature and relative humidity. Comparisons with road test data indicated that the program was capable of predicting the performance of the automotive air-conditioning system with reasonable accuracy.

  14. 75 FR 6338 - Protection of Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector...

    Science.gov (United States)

    2010-02-09

    ... to use conditions as a substitute for CFC-12 in motor vehicle air conditioning. The proposed... AGENCY 40 CFR Part 82 Protection of Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector Under the Significant New Alternatives Policy (SNAP) Program AGENCY: Environmental...

  15. Poaceae pollen in the air depending on the thermal conditions

    Science.gov (United States)

    Myszkowska, Dorota

    2014-07-01

    The relationship between the meteorological elements, especially the thermal conditions and the Poaceae pollen appearance in the air, were analysed as a basis to construct a useful model predicting the grass season start. Poaceae pollen concentrations were monitored in 1991-2012 in Kraków using the volumetric method. Cumulative temperature and effective cumulative temperature significantly influenced the season start in this period. The strongest correlation was seen as the sum of mean daily temperature amplitudes from April 1 to April 14, with mean daily temperature >15 °C and effective cumulative temperature >3 °C during that period. The proposed model, based on multiple regression, explained 57 % of variation of the Poaceae season starts in 1991-2010. When cumulative mean daily temperature increased by 10 °C, the season start was accelerated by 1 day. The input of the interaction between these two independent variables into the factor regression model caused the increase in goodness of model fitting. In 2011 the season started 5 days earlier in comparison with the predicted value, while in 2012 the season start was observed 2 days later compared to the predicted day. Depending on the value of mean daily temperature from March 18th to the 31st and the sum of mean daily temperature amplitudes from April 1st to the 14th, the grass pollen seasons were divided into five groups referring to the time of season start occurrence, whereby the early and moderate season starts were the most frequent in the studied period and they were especially related to mean daily temperature in the second half of March.

  16. The Future of Air Conditioning for Buildings - Executive Summary

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Young, J. [Navigant Consulting Inc., Burlington, MA (United States); Fuhrman, J. [Navigant Consulting Inc., Burlington, MA (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    The Building Technologies Office (BTO), within the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy, works with researchers and industry to develop and deploy technologies that can substantially reduce energy consumption and greenhouse gas (GHG) emissions in residential and commercial buildings. Air conditioning (A/C) systems in buildings contribute to GHG emissions both directly through refrigerant emissions, as well as indirectly through fossil fuel combustion for power generation. BTO promotes pre-competitive research and development (R&D) on next-generation HVAC technologies that support the phase down of hydrofluorocarbon (HFC) production and consumption, as well as cost-effective energy efficiency improvements. Over the past several decades, product costs and lifecycle cooling costs have declined substantially in many global markets due to improved, higher-volume manufacturing and higher energy efficiency driven by R&D investments and efficiency policies including minimum efficiency standards and labeling programs.1 This report characterizes the current landscape and trends in the global A/C market, including discussion of both direct and indirect climate impacts, and potential global warming impacts from growing global A/C usage. The report also documents solutions that can help achieve international goals for energy efficiency and GHG emissions reductions. The solutions include pathways related to low-global warming potential2 (GWP) refrigerants, energy efficiency innovations, long-term R&D initiatives, and regulatory actions. DOE provides, with this report, a fact-based vision for the future of A/C use around the world. DOE intends for this vision to reflect a broad and balanced aggregation of perspectives. DOE brings together this content in an effort to support dialogue within the international community and help keep key facts and objectives at the forefront among the many important discussions.

  17. A geophysical shock and air blast simulator at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B.; Brown, C. G.; May, M. J.; Compton, S.; Walton, O. R.; Shingleton, N.; Kane, J. O.; Holtmeier, G.; Loey, H.; Mirkarimi, P. B.; Dunlop, W. H. [Lawrence Livermore National Laboratory, P.O. Box 808, L-481, Livermore, California 94550 (United States); Guyton, R. L.; Huffman, E. [National Securities Technologies, Vasco Rd., Livermore, California 94551 (United States)

    2014-09-15

    The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

  18. A geophysical shock and air blast simulator at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, K. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brown, C. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); May, M. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Compton, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Walton, O. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shingleton, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kane, J. O. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Holtmeier, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Loey, H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mirkarimi, P. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dunlop, W. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Guyton, R. L. [National Security Technologies, Livermore, CA (United States); Huffman, E. [National Security Technologies, Livermore, CA (United States)

    2014-09-01

    The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

  19. Innovative pollution prevention program at Air Force owned Raytheon operated facility incorporating Russian technology

    Energy Technology Data Exchange (ETDEWEB)

    Stallings, J.H.; Cepeda-Calderon, S.

    1999-07-01

    Air Force Plant 44 in Tucson, Arizona is owned by the Air Force and operated by Raytheon Missile Systems Company. A joint Air Force/Raytheon Pollution Prevention Team operates at AFP 44 with the ultimate goal to minimize or eliminate the use of hazardous substances. The team works together to uncover new technologies and methods that will replace chemicals used in the plant's missile manufacturing facilities. The program maximizes pollution prevention by first eliminating hazardous material use, then chemical recycling, next hazardous waste reduction and finally wastewater treatment and recycling. From fiscal years 1994 through 1997, nine pollution prevention projects have been implemented, totaling $2.6 million, with a payback averaging less than two years. A unique wastewater treatment method has been demonstrated as part of this program. This is electroflotation, a Russian technology which removes dispersed particles from liquid with gas bubbles obtained during water electrolysis. A unit was built in the US which successfully removed organic emulsions from wastewater. Operational units are planned for the removal of waste from waterfall paint booths. The pollution prevention joint team continues to be very active with two projects underway in FY 98 and two more funded for FY 99.

  20. A discussion of regulatory requirements and air dispersion modeling approaches applicable to U.S. chemical demilitarization facilities.

    Science.gov (United States)

    Higgins, B W; Robbins, L B; Litynski, J

    1998-09-01

    Owners of hazardous waste treatment, storage, and disposal facilities, and certain major air pollution sources, must conduct several separate ambient air dispersion modeling analyses before beginning construction of new facilities or modifying existing facilities. These analyses are critical components of the environmental permitting and facility certification processes and must be completed to the satisfaction of federal, state, and local regulatory authorities. The U.S. Army has conducted air dispersion modeling for its proposed chemical agent disposal facilities to fulfill the following environmental regulatory and risk management requirements: (1) Resource Conservation and Recovery Act human health and ecological risk assessment analysis for the hazardous waste treatment and storage permit applications, (2) Quantitative Risk Assessment to support the site-specific risk management programs, and (3) Prevention of Significant Deterioration ambient air impact analysis for the air permit applications. The purpose of these air dispersion modeling studies is to show that the potential impacts on human health and the environment, due to operation of the chemical agent disposal facilities, are acceptable. This paper describes and compares the types of air dispersion models, modeling input data requirements, modeling algorithms, and approaches used to satisfy the three environmental regulatory and risk management requirements listed above. Although this paper discusses only one industry (i.e., chemical demilitarization), the information it contains could help those in other industries who need to communicate to the public the purpose and objectives of each modeling analysis. It may also be useful in integrating the results of each analysis into an overarching summary of compliance and potential risks.

  1. Cooling Performance Characteristics on Mobile Air-Conditioning System for Hybrid Electric Vehicles

    OpenAIRE

    Ho-Seong Lee; Moo-Yeon Lee

    2013-01-01

    This study investigates the cooling performance characteristics of the mobile air-conditioning system using R744 (CO2) for the hybrid electric vehicle as an alternative to both the R-134a and the conventional air-conditioning system. The developed air-conditioning system is operated with an electric driven compressor in the battery driving mode and a belt driven compressor in the engine driving mode. The cooling performance characteristics of the developed system have been analyzed by experim...

  2. PRINCIPLES OF SAFETY MANAGEMENT OF AIR TRAFFIC FLOWS AND CAPACITY UNDER UNCERTAINTY CONDITIONS

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2016-11-01

    Full Text Available Purpose: The aim of this study is to investigate the general principles of safety and capacity management in Aeronautical systems regarding air traffic flows operations under uncertainty conditions. In this work the theoretical framework assessing at the same time both the uncertainty model and flight plans model are proposed. Methods: To study features of safety of air traffic flows and capacity under uncertainty conditions were built the original probabilistic models including Bayesian Network for flight plan and air traffic control sector model based on Poisson Binomial Distribution. Results: We obtained models for safety management of air traffic flows and capacity under uncertainty conditions. We discussed appropriate approach for estimating the parameters of safety of air traffic flows and capacity under uncertainty and Markovian uncertainty model for the flight plan. Discussion: We developed the Bayesian Network for flight plan and air traffic control sector models for safety management of air traffic flows and capacity under uncertainty conditions.

  3. Solar thermal plant of air tube for solar air conditioning; Planta Solar Termica de tubos de vacio para aire acondicionado solar

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J. C.; Lopez, J.; Coronas, A.

    2004-07-01

    The present implementation of refrigeration and air conditioning technologies driven by thermal solar energy is very limited although there is a great market demand for them for environmental reasons and security of energy supply. In this paper it is presented a detailed technical description of the solar plant installed at the technological Innovation Centre CREVER, and an example of a complete energy analysis of this plant working under the required conditions to be used for solar air conditioning applications. Also it is included a review of solar air conditioning systems state of the art. (Author)

  4. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2002-01-01

    in the built environment: better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; personalized ventilation, i.e. small amounts of clean air, should be provided gently, close...... though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in buildings in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence...

  5. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1999-01-01

    : better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; small amounts of clean air should be served gently, close to the breathing zone of each individual; individual......, even though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence...

  6. LSST summit facility construction progress report: reacting to design refinements and field conditions

    Science.gov (United States)

    Barr, Jeffrey D.; Gressler, William; Sebag, Jacques; Seriche, Jaime; Serrano, Eduardo

    2016-07-01

    The civil work, site infrastructure and buildings for the summit facility of the Large Synoptic Survey Telescope (LSST) are among the first major elements that need to be designed, bid and constructed to support the subsequent integration of the dome, telescope, optics, camera and supporting systems. As the contracts for those other major subsystems now move forward under the management of the LSST Telescope and Site (T and S) team, there has been inevitable and beneficial evolution in their designs, which has resulted in significant modifications to the facility and infrastructure. The earliest design requirements for the LSST summit facility were first documented in 2005, its contracted full design was initiated in 2010, and construction began in January, 2015. During that entire development period, and extending now roughly halfway through construction, there continue to be necessary modifications to the facility design resulting from the refinement of interfaces to other major elements of the LSST project and now, during construction, due to unanticipated field conditions. Changes from evolving interfaces have principally involved the telescope mount, the dome and mirror handling/coating facilities which have included significant variations in mass, dimensions, heat loads and anchorage conditions. Modifications related to field conditions have included specifying and testing alternative methods of excavation and contending with the lack of competent rock substrate where it was predicted to be. While these and other necessary changes are somewhat specific to the LSST project and site, they also exemplify inherent challenges related to the typical timeline for the design and construction of astronomical observatory support facilities relative to the overall development of the project.

  7. Impact of air conditioning system operation on increasing gases emissions from automobile

    Science.gov (United States)

    Burciu, S. M.; Coman, G.

    2016-08-01

    The paper presents a study concerning the influence of air conditioning system operation on the increase of gases emissions from cars. The study focuses on urban operating regimes of the automobile, regimes when the engines have low loads or are operating at idling. Are presented graphically the variations of pollution emissions (CO, CO2, HC) depending of engine speed and the load on air conditioning system. Additionally are presented, injection duration, throttle position, the mechanical power required by the compressor of air conditioning system and the refrigerant pressure variation on the discharge path, according to the stage of charging of the air conditioning system.

  8. [Design, equipment, and management for air conditioning in operating room].

    Science.gov (United States)

    Fuji, Kumiko; Mizuno, Ju

    2011-11-01

    In order to maintain air cleanliness in the operating room (OR) permanently, air exchange rate in the OR should be more than 15 times x hr(-1), the laminar air flow should be kept, and the numbers of the persons in the OR and the numbers of opening and closing OR door should be limited. High efficiency particulate air (HEPA) filter is effective in collection and removal of airborne microbes, and is used in the biological clean room. We need to design, equip, and manage the OR environment according to Guideline for Design and Operation of Hospital HVAC Systems HEAS-02-2004 established by Healthcare Engineering Association of Japan and Guideline for Prevention of Surgical Site Infection (SSI) established by the Center for Disease Control and Prevention (CDC) in the USA.

  9. COMPOSITION CHANGES IN REFRIGERANT BLENDS FOR AUTOMOTIVE AIR CONDITIONING

    Science.gov (United States)

    Three refrigerant blends used to replace CFC-12 in automotive air conditioners were evaluated for composition changes due to typical servicing and leakage. When recommended service procedures were followed, changes in blend compositions were relatively small. Small changes in b...

  10. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  11. Research of the Temperature and Humidity Processes in the Air Conditioning Apparatus Varying Air Ion Concentration

    Directory of Open Access Journals (Sweden)

    Marchenko V. G.

    2015-12-01

    Full Text Available To create comfortable conveniences for people in the room, we have to process the indoor air in the AC apparatus. Depending on given air parameters in the room, the air processing comprises the next steps: heating, cooling, wetting, drying. Except the compliance of the temperature and humidity parameters of air, we must control its ionic composition. Thereby, the experimental analysis of the air preparing in the AC apparatus is given in this article. Thank to that analysis, we can estimate the ionic and deionic impact on the air space in the specific processes of the air preparing. According to the results of experiments, we have identified, that the air temperature varying does not have significant effect on the ionic concentration. The ionic increasing after electric heater is not associated with air temperature. It is the consequence of the electron extrication from the surface of the heating element. Reducing ion moving the high air humidity decreases the concentration of the lightweight ions. The increasing of the ions in the spray-type air washers is explained by ballo-electric effect of spraying water drops, but not the air humidity rising.

  12. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...

  13. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs.

  14. Development of residential solar air conditioning system for electricity power peak cut 3

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Gwon Jong [Korea Inst. of Energy and Resources, Daeduk (Korea, Republic of)

    1995-12-31

    In this research, the converter rectifier unit of the inverter air conditioner is substituted into the bidirectional PWM converter. The DC/DC power converter is established on the DC link between the photovoltaic array and the inverter air conditioner, and the photovoltaic air conditioning system which can be parallel driven which utility is developed. (author). 35 ref., 112 figs.

  15. Spent nuclear fuel project cold vacuum drying facility process water conditioning system design description

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1998-11-30

    This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Process Water Conditioning (PWC) System. The SDD was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), the HNF-SD-SNF-DRD-O02, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the PWC equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SDD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

  16. MODERN CONDITIONS OF ROAD FACILITIES AND INTERNATIONAL AUTOMOTIVE TRANSPORTATION OF THE REPUBLIC OF BELARUS

    Directory of Open Access Journals (Sweden)

    I. M. Tsarenkova

    2008-01-01

    Full Text Available For analysis of technical and economic conditions of automotive roads and determination of reserves for improvement of financial situation and usage of capital in road facilities operational efficiency of road facilities and automotive freight-traffic services that provide significant currency receipt for Republic budget. The main ways for higher export of construction services are involvement of road facilities enterprises in this activity and introduction of highly-productive technologies in their operation. The paper demonstrates an importance of non-conventional sources of investment attractions such as leasing which is used for renovation of capital assets and invests resources in the basic capital on the return basis in the natural form. For application of new technologies and modern technique it is justifiable to establish joint road-construction enterprises with foreign sub-contractors. The paper reveals main reasons of profit increase due to operation and services of road branch.

  17. Francisella guangzhouensis sp. nov., isolated from air-conditioning systems.

    Science.gov (United States)

    Qu, Ping-Hua; Chen, Shou-Yi; Scholz, Holger C; Busse, Hans-Jürgen; Gu, Quan; Kämpfer, Peter; Foster, Jeffrey T; Glaeser, Stefanie P; Chen, Cha; Yang, Zhi-Chong

    2013-10-01

    Four strains (08HL01032(T), 09HG994, 10HP82-6 and 10HL1960) were isolated from water of air-conditioning systems of various cooling towers in Guangzhou city, China. Cells were Gram-stain-negative coccobacilli without flagella, catalase-positive and oxidase-negative, showing no reduction of nitrate, no hydrolysis of urea and no production of H2S. Growth was characteristically enhanced in the presence of l-cysteine, which was consistent with the properties of members of the genus Francisella. The quinone system was composed of ubiquinone Q-8 with minor amounts of Q-9. The polar lipid profile consisted of the predominant lipids phosphatidylethanolamine, diphosphatidylglycerol, phosphatidylglycerol, phosphatidylcholine, two unidentified phospholipids (PL2, PL3), an unidentified aminophospholipid and an unidentified glycolipid (GL2). The polyamine pattern consisted of the major compounds spermidine, cadaverine and spermine. The major cellular fatty acids were C10 : 0, C14 : 0, C16 : 0, C18 : 1ω9c and C18 : 1 3-OH. A draft whole-genome sequence of the proposed type strain 08HL01032(T) was generated. Comparative sequence analysis of the complete 16S and 23S rRNA genes confirmed affiliation to the genus Francisella, with 95 % sequence identity to the closest relatives in the database, the type strains of Francisella philomiragia and Francisella noatunensis subsp. orientalis. Full-length deduced amino acid sequences of various housekeeping genes, recA, gyrB, groEL, dnaK, rpoA, rpoB, rpoD, rpoH, fopA and sdhA, exhibited similarities of 67-92 % to strains of other species of the genus Francisella. Strains 08HL01032(T), 09HG994, 10HP82-6 and 10HL1960 exhibited highly similar pan-genome PCR profiles. Both the phenotypic and molecular data support the conclusion that the four strains belong to the genus Francisella but exhibit considerable divergence from all recognized Francisella species. Therefore, we propose the name Francisella guangzhouensis sp

  18. Residential air-conditioning and climate change: voices of the vulnerable.

    Science.gov (United States)

    Farbotko, Carol; Waitt, Gordon

    2011-12-01

    Decreasing the risk of heat-stress is an imperative in health promotion, and is widely accepted as necessary for successful adaptation to climate change. Less well understood are the vulnerabilities that air-conditioning use exacerbates, and conversely, the need for the promotion of alternative strategies for coping with heat wave conditions. This paper considers these issues with a focus on the role of air-conditioning in the everyday life of elderly public housing tenants living alone, a sector of the population that has been identified as being at high risk of suffering heat stress. A vulnerability analysis of domestic air-conditioning use, drawing on literature and policy on air-conditioning practices and ethnographic research with households. Residential air-conditioning exacerbated existing inequities. Case studies of two specifically selected low-income elderly single person households revealed that such households were unlikely to be able to afford this 'solution' to increasing exposure to heat waves in the absence of energy subsidies. Residential air-conditioning use during heat waves caused unintended side-effects, such as system-wide blackouts, which, in turn, led to escalating electricity costs as power companies responded by upgrading infrastructure to cope with periods of excess demand. Air-conditioning also contributed to emissions that cause climate change. Residential air-conditioning is a potentially maladaptive technology for reducing the risk of heat stress.

  19. The system of thermoelectric air conditioning based on permeable thermoelements

    Directory of Open Access Journals (Sweden)

    Cherkez R. G.

    2009-04-01

    Full Text Available There is thermoelectric air conditioner unit on the basis of permeable cooling thermoelements presented. In thermoelectric air conditioner unit the thermoelectric effects and the Joule–Thomson effect have been used for the air stream cooling. There have been described the method of temperature distribution analysis, the determinations of energy conversion power characteristics and design style of permeable thermoelement with maximum coefficient of performance described. The results of computer analysis concerning the application of the thermoelement legs material on the basis of Bi2Te3 have shown the possibility of coefficient of performance increase by a factor of 1,6—1,7 as compared with conventional thermoelectric systems.

  20. The relationship between science classroom facility conditions and ninth grade students' attitudes toward science

    Science.gov (United States)

    Ford, Angela Y.

    Over half of the school facilities in America are in poor condition. Unsatisfactory school facilities have a negative impact on teaching and learning. The purpose of this correlational study was to identify the relationship between high school science teachers' perceptions of the school science environment (instructional equipment, demonstration equipment, and physical facilities) and ninth grade students' attitudes about science through their expressed enjoyment of science, importance of time spent on science, and boredom with science. A sample of 11,523 cases was extracted, after a process of data mining, from a databank of over 24,000 nationally representative ninth graders located throughout the United States. The instrument used to survey these students was part of the High School Longitudinal Study of 2009 (HSLS:2009). The research design was multiple linear regression. The results showed a significant relationship between the science classroom conditions and students' attitudes. Demonstration equipment and physical facilities were the best predictors of effects on students' attitudes. Conclusions based on this study and recommendations for future research are made.

  1. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  2. [Sanitary and epidemiological evaluation of the ventilation and air-conditioning systems of public buildings].

    Science.gov (United States)

    Dvorianov, V V

    2012-01-01

    The microbial contamination of ventilation and air conditioning systems was examined in the administrative buildings. The author proposes a set of indicators, methods for determining the scope of investigations, as well as sampling tactics and criteria for evaluating the microbial contamination of the ventilation and air-conditioning systems. The content of yeasts and molds in the delivered air has been found to be of importance for evaluating the sanitary-and epidemiological state of ventilation systems.

  3. 2014 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2014. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  4. The Effect of Air-Conditioning on Student and Teacher Performance.

    Science.gov (United States)

    Phoenix Union High School District, AZ. Dept. of Research and Planning.

    The literature is reviewed to see if research shows a relationship between student and teacher performance and air conditioning of classrooms. The benefits of air conditioning in promoting learning are substantiated by studies that are summarized but not cited. The relationship of the report to the Phoenix Union High School System Advisory…

  5. Automotive Air Conditioning and Heating; Automotive Mechanics (Advanced): 9047.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to provide the student with all the foundations necessary to become employable in the automotive air conditioning and heating trade. The course of study includes an orientation to the world of work, the elementary physics of air conditioning and heating, and laboratory experiments…

  6. Air-Puff Conditioning Audiometry: Extending Its Applicability with Multiply Handicapped Individuals.

    Science.gov (United States)

    Lancioni, G. E.; And Others

    1990-01-01

    This study examined the use of air-puff conditioning audiometry in the hearing assessment of 12 multiply handicapped (including severe/profound mental retardation) subjects, ages 9-32. Ten subjects reached criterion conditioning and then completed the hearing assessment with the air-puff procedure while one reached criterion with a modified…

  7. The Effect of Air-Conditioning on Student and Teacher Performance.

    Science.gov (United States)

    Phoenix Union High School District, AZ. Dept. of Research and Planning.

    The literature is reviewed to see if research shows a relationship between student and teacher performance and air conditioning of classrooms. The benefits of air conditioning in promoting learning are substantiated by studies that are summarized but not cited. The relationship of the report to the Phoenix Union High School System Advisory…

  8. Criterion-Referenced Test (CRT) Items for Air Conditioning, Heating and Refrigeration.

    Science.gov (United States)

    Davis, Diane, Ed.

    These criterion-referenced test (CRT) items for air conditioning, heating, and refrigeration are keyed to the Missouri Air Conditioning, Heating, and Refrigeration Competency Profile. The items are designed to work with both the Vocational Instructional Management System and Vocational Administrative Management System. For word processing and…

  9. Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Aldrich, R.; Arena, L.

    2012-07-01

    This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

  10. Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Aldrich, Robb [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, Lois [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-07-01

    This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

  11. Subsurface Thermal Energy Storage for Improved Air Conditioning Efficiency

    Science.gov (United States)

    2016-11-01

    current cost liability is the potential for several significant structural changes at DoD facilities around the world. These challenges include...requires access to a productive aquifer with associated permitting and water chemistry considerations. Closed loop systems use sealed piping to... climate , with an average high temperature of 90 degrees in July, and an average low temperature of 39 in January. The annual average temperature is 65.6

  12. Design of a Regenerable Air Revitalization Control System for the ABRS Plant Growth Facility

    Science.gov (United States)

    Monje, Oscar; Monje, Oscar; Shellack, James; Mortenson, Todd; Wells, Howard

    Design of a Regenerable Air Revitalization Control System for the ABRS Plant Growth Facility. O. Monje Space Life Sciences Laboratory, Dynamac Corp., DYN-3, Kennedy Space Center, FL 32899, USA J.L. Shellack, T.E. Mortenson, and H.W. Wells. Bionetics Corporation, BIO-1, Kennedy Space Center, FL 32899, USA The Advanced Biological Research System (ABRS) is a rear-breathing, single middeck locker equivalent plant growth system. ABRS is composed of two independently controlled growth chambers (each with 330 cm2 of growth area). The air revitalization system in each chamber is composed of two subsystems: CO2 Control and a Ethylene/VOC Control. The CO2 Control subsystem must control chamber [CO2] within a range of 300-2000 ppm, with a nominal setpoint of 1500 ppm. The Ethylene/VOC Control subsystem is required to maintain chamber ethylene concentration at ¡50 ppb. Previous spaceflight plant payloads have used non-regenerable cartridges for CO2 control and photocatalytic scrubbers for controlling concentrations of volatile organic compounds (VOCs). Non-regenerable systems have used LiOH cartridges for [CO2] control with a combination of Purafil (KMnO4)/Activated charcoal for scrubbing VOCs. Regenerable air revitalization systems offer the potential for reducing the mass and volume of consumables used during spaceflight plant experiments. A system utilizing technologies employing regenerable adsorbents: zeolites 13X and 5A for CO2 control and Carbosieve SIII (C molecular sieve) for VOC control has been designed for ABRS. The filter cartridges were sized using expected chamber leak rates, measurements of adsorptive capacities, and measured CO2 consumption and VOC generation rates.

  13. Application of Fuzzy Comprehensive Evaluation to Air-conditioning Competitive Power Analysis

    Institute of Scientific and Technical Information of China (English)

    LU Congda; LIU Gaojin; JIANG Shaofei; LV Chaoqun

    2006-01-01

    As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD), customer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product designing. Lots of information in the process of this research is fuzzy and uncertain, but traditional QFD can not deal with it well. Fuzzy theory can solve the problem. So a fuzzy model for analyzing product competitive power is formulated in this paper to improve traditional QFD, after that it is applied to analyze air-conditioning competitive power. When air-conditioning competitive power is analyzed using this model, firstly the importance weight of the customer requirements of air-conditioning is determined using the Analytic Hierarchy Process (AHP) weighting process, then air-conditioning competitive power is evaluated using fuzzy comprehensive evaluation. It is proved that the model is feasible and has good applicability.

  14. Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

    2014-09-01

    Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

  15. Optimizing Facility Configurations and Operating Conditions for Improved Performance in the NASA Ames 24 Inch Shock Tube

    Science.gov (United States)

    Bogdanoff, David W.; Cruden, Brett A.

    2016-01-01

    The Ames Electric Arc Shock Tube (EAST) is a shock tube wherein the driver gas can be heated by an electric arc discharge. The electrical energy is stored in a 1.2 MJ capacitor bank. Four inch and 24 inch diameter driven tubes are available. The facility is described and the need for testing in the 24 inch tube to better simulate low density NASA mission profiles is discussed. Three test entries, 53, 53B and 59, are discussed. Tests are done with air or Mars gas (95.7% CO2/2.7% N2/1.6% Ar) at pressures of 0.01 to 0.14 Torr. Velocities spanned 6.3-9.2 km/s, with a nominal center of 7 km/s. Many facility configurations are studied in an effort to improve data quality. Various driver and driven tube configurations and the use of a buffer section between the driver and the driven tube are studied. Diagnostics include test times, time histories of the shock light pulses and tilts of the shock wave off the plane normal to the tube axis. The report will detail the results of the various trials, give the best configuration/operating conditions found to date and provide recommendations for further improvements. Finally, diaphragm performance is discussed.

  16. Reducing indoor air pollution by air conditioning is associated with improvements in cardiovascular health among the general population.

    Science.gov (United States)

    Lin, Lian-Yu; Chuang, Hsiao-Chi; Liu, I-Jung; Chen, Hua-Wei; Chuang, Kai-Jen

    2013-10-01

    Indoor air pollution is associated with cardiovascular effects, however, little is known about the effects of improving indoor air quality on cardiovascular health. The aim of this study was to explore whether improving indoor air quality through air conditioning can improve cardiovascular health in human subjects. We recruited a panel of 300 healthy subjects from Taipei, aged 20 and over, to participate in six home visits each, to measure a variety of cardiovascular endpoints, including high sensitivity-C-reactive protein (hs-CRP), 8-hydroxy-2'-deoxyguanosine (8-OHdG), fibrinogen in plasma and heart rate variability (HRV). Indoor particles and total volatile organic compounds (VOCs) were measured simultaneously at the participant's home during each visit. Three exposure conditions were investigated in this study: participants were requested to keep their windows open during the first two visits, close their windows during the next two visits, and close the windows and turn on their air conditioners during the last two visits. We used linear mixed-effects models to associate the cardiovascular endpoints with individual indoor air pollutants. The results showed that increases in hs-CRP, 8-OHdG and fibrinogen, and decreases in HRV indices were associated with increased levels of indoor particles and total VOCs in single-pollutant and two-pollutant models. The effects of indoor particles and total VOCs on cardiovascular endpoints were greatest during visits with the windows open. During visits with the air conditioners turned on, no significant changes in cardiovascular endpoints were observed. In conclusion, indoor air pollution is associated with inflammation, oxidative stress, blood coagulation and autonomic dysfunction. Reductions in indoor air pollution and subsequent improvements in cardiovascular health can be achieved by closing windows and turning on air conditioners at home. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Cooling Performance Characteristics on Mobile Air-Conditioning System for Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Ho-Seong Lee

    2013-01-01

    Full Text Available This study investigates the cooling performance characteristics of the mobile air-conditioning system using R744 (CO2 for the hybrid electric vehicle as an alternative to both the R-134a and the conventional air-conditioning system. The developed air-conditioning system is operated with an electric driven compressor in the battery driving mode and a belt driven compressor in the engine driving mode. The cooling performance characteristics of the developed system have been analyzed by experiments under various operating conditions of inlet air temperature, air flow rates for the gas cooler side and evaporator side, and electric compressor revolution respectively. As a result, cooling performances of the tested air-conditioning system for the EDC driving mode (electricity driven compressor were better than those for the BDC driving mode (belt driven compressor. The cooling capacity and cooling COP of the tested air-conditioning system for both driving modes were over 5.0 kW and 2.0, respectively. The observed cooling performance of the tested air-conditioning system may be sufficient for the cabin cooling of hybrid electric vehicles.

  18. Radioactive Air Emmission Notice of Construction (NOC) for the Waste Receiving and Processing Facility (WRAP)

    Energy Technology Data Exchange (ETDEWEB)

    MENARD, N.M.

    2000-12-01

    This document serves as a notice of construction (NOC) pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060, and as a request for approval to modify pursuant to 40 Code of Federal Regulations (CFR) 61.07 for the Waste Receiving and Processing (WRAP) Facility. The rewrite of this NOC incorporates all the approved revisions (Sections 5.0, 6.0, 8.0, and 9.0), a revised potential to emit (PTE) based on the revised maximally exposed individual (MEI) (Sections 8.0, 10.0, 11.0, 12.0, 13.0, 14.0, and 15.0), the results of a study on fugitive emissions (Sections 6.0, 10.0, and 15.0), and reflects the current operating conditions at the WRAP Facility (Section 5.0). This NOC replaces DOE/RL-93-15 and DOE/RL-93-16 in their entirety. The primary function of the WRAP Facility is to examine, assay, characterize, treat, verify, and repackage radioactive material and mixed waste. There are two sources of emissions from the WRAP Facility: stack emissions and fugitive emissions. The stack emissions have an unabated total effective dose equivalent (TEDE) estimate to the hypothetical offsite MEI of 1.13 E+02 millirem per year. The abated TEDE for the stack emissions is estimated at 5.63 E-02 millirem per year to the MEI. The fugitive emissions have an unabated TEDE estimate to the hypothetical offsite MEI of 5.87 E-04. There is no abatement for the fugitive emissions.

  19. Influence of Cooling to Heating Load Ratio on Optimal Supply Water and Air Temperatures in an Air Conditioning System

    Science.gov (United States)

    Karino, Naoki; Shiba, Takashi; Yokoyama, Ryohei; Ito, Koichi

    In planning an air conditioning system, supply water and air temperatures are important factors from the viewpoint of energy saving and cost reduction. For example, lower temperature supply water and air for space cooling reduce the coefficient of performance of a refrigeration machine, and increase the thickness of heat insulation material. However, they enable larger temperature differences, and reduce equipment sizes and power demand. It is also an important subject to evaluate the effect of the supply water and air temperatures on energy saving and cost reduction on the annual basis by considering not only cooling but also heating loads. The purposes of this paper are to propose an optimal planning method for an air conditioning system with large temperature difference, and to analyze the effect of supply water and air temperatures on the long-term economics through a numerical study for an office building. As a result, it is shown that the proposed method effectively determines supply water and air temperatures, and the influence of the cooling to heating load ratio on the long-term economics is clarified.

  20. Calculation of the Chilling Requirement for Air Conditioning in the Excavation Roadway

    Directory of Open Access Journals (Sweden)

    Yueping Qin

    2015-10-01

    Full Text Available To effectively improve the climate conditions of the excavation roadway in coal mine, the calculation of the chilling requirement taking air conditioning measures is extremely necessary. The temperature field of the surrounding rock with moving boundary in the excavation roadway was numerically simulated by using finite volume method. The unstable heat transfer coefficient between the surrounding rock and air flow was obtained via the previous calculation. According to the coupling effects of the air flow inside and outside air duct, the differential calculation mathematical model of air flow temperature in the excavation roadway was established. The chilling requirement was calculated with the selfdeveloped computer program for forecasting the required cooling capacity of the excavation roadway. A good air conditioning effect had been observed after applying the calculated results to field trial, which indicated that the prediction method and calculation procedure were reliable.

  1. Performance and evaluation of gas-engine-driven rooftop air conditioning equipment at the Willow Grove Naval Air Station. Final report (revised October 21, 1996)

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Katipamula, S.

    1996-10-01

    The performance was evaluated of a new US cooling technology that has been installed for the first time at a federal facility. The technology is a 15-ton natural gas-engine-driven rooftop air conditioning unit made by Thermo King. Two units were installed to serve the Navy Exchange at Willow Grove. The savings potential at Willow Grove is described and that in the federal sector estimated. Conditions for implementation are discussed. In summary, the new technology is generally cost-effective at sites where marginal electricity cost (per MBtu at the meter) is more than 4 times the marginal gas cost (per MBtu at the meter) and annual full-load-equivalent cooling hours exceed 2,000.

  2. Air entrainment by a plunging jet under intermittent vortex conditions

    OpenAIRE

    Kim, Kevin Jin; Corfman, Kyle; Li, Kevin; Kiger, Ken T.

    2011-01-01

    This fluid dynamic video entry to the 2011 APS-DFD Gallery of Fluid Motion details the transient evolution of the free surface surrounding the impact region of a low-viscosity laminar liquid jet as it enters a quiescent pool. The close-up images depict the destabilization and breakup of the annular air gap and the subsequent entrainment of bubbles into the bulk liquid.

  3. Combustion of Gaseous Fuels with High Temperature Air in Normal- and Micro-gravity Conditions

    Science.gov (United States)

    Wang, Y.; Gupta, A. K.

    2001-01-01

    The objective of this study is determine the effect of air preheat temperature on flame characteristics in normal and microgravity conditions. We have obtained qualitative (global flame features) and some quantitative information on the features of flames using high temperature combustion air under normal gravity conditions with propane and methane as the fuels. This data will be compared with the data under microgravity conditions. The specific focus under normal gravity conditions has been on determining the global flame features as well as the spatial distribution of OH, CH, and C2 from flames using high temperature combustion air at different equivalence ratio.

  4. The Design of Research Laboratories. Part I: A General Assessment. Part II: Air Conditioning and Conditioned Rooms.

    Science.gov (United States)

    Legget, R. F.; Hutcheon, N. B.

    Design factors in the planning of research laboratories are described which include--(1) location, (2) future expansion, (3) internal flexibility, (4) provision of services, (5) laboratory furnishing, (6) internal traffic, (7) space requirements, and (8) building costs. A second part discusses air-conditioning and conditioned rooms--(1)…

  5. Design and verification of shielding for the advanced spent fuel conditioning process facility.

    Science.gov (United States)

    Cho, I J; Kook, D H; Kwon, K C; Lee, E P; Choung, W M; You, G S

    2008-05-01

    An Advanced spent fuel Conditioning Process Facility (ACPF) has recently been constructed by a modification of previously unused cells. ACPF is a hot cell with two rooms located in the basement of the Irradiated Materials Experiment Facility (IMEF) at the Korea Atomic Energy Research Institute. This is for demonstrating the advanced spent fuel conditioning process being proposed in Korea, which is an electrolytic reduction process of spent oxide fuels into a metallic form. The ACPF was designed with a more than 90 cm thick high density concrete shield wall to handle 1.38 PBq (37,430 Ci) of radioactive materials with dose rates lower than 10 muSv h in the operational areas (7,000 zone) and 150 muSv h in the service areas (8,000 zone). In Monte Carlo calculations with a design basis source inventory, the results for the bounding wall showed a maximum of 3 muSv h dose rate at an exterior surface of the ACPF for gamma radiation and 0.76 muSv h for neutrons. All the bounding structures of the ACPF were investigated to check on the shielding performance of the facility to ensure the radiation safety of the facility. A test was performed with a 2.96 TBq (80 Ci) 60Co source unit and the test results were compared with the calculation results. A few failure points were discovered and carefully fixed to meet the design criteria. After fixing the problems, the failure points were rechecked and the safety of the shielding structures was confirmed. In conclusion, it was confirmed that all the investigated parts of the ACPF passed the shielding safety limits by using this program and the ACPF is ready to fulfill its tasks for the advanced spent fuel conditioning process.

  6. A study of energy use for ventilation and air-conditioning systems in Hong Kong

    Science.gov (United States)

    Yu, Chung Hoi Philip

    Most of the local modern buildings are high-rise with enclosed structure. Mechanical ventilation and air conditioning (MVAC) systems are installed for thermal comfort. Various types of MVAC systems found in Hong Kong were critically reviewed with comments on their characteristics in energy efficiency as well as application. The major design considerations were also discussed. Besides MVAC, other energy-consuming components in commercial buildings were also identified, such as lighting, lifts and escalators, office equipment, information technology facilities, etc. A practical approach has been adopted throughout this study in order that the end results will have pragmatic value to the heating, ventilating and air-conditioning (HVAC) industry in Hong Kong. Indoor Air Quality (IAQ) has become a major issue in commercial buildings worldwide including Hong Kong. Ventilation rate is no doubt a critical element in the design of HVAC systems, which can be realized more obviously in railway train compartments where the carbon dioxide level will be built up quickly when the compartments are crowded during rush hours. A study was carried out based on a simplified model using a train compartment that is equipped with an MVAC system. Overall Thermal Transfer Value (OTTV) is a single-value parameter for controlling building energy use and is relatively simple to implement legislatively. The local government has taken a first step in reacting to the worldwide concern of energy conservation and environmental protection since 1995. Different methods of OTTV calculation were studied and the computation results were compared. It gives a clear picture of the advantages and limitations for each method to the building designers. However, due to the limitations of using OTTV as the only parameter for building energy control, some new approaches to a total control of building energy use were discussed and they might be considered for future revision of the building energy codes in Hong

  7. Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Bergero, Stefano; Chiari, Anna [DIPARC, Faculty of Architecture, University of Genoa, Stradone S. Agostino 37, 16123 Genova (Italy)

    2010-11-15

    The present study examines the performances of a hybrid air-conditioning system in which a vapour-compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This model may be a valid alternative to traditional summertime air-conditioning system, in which the air is cooled to below its dew-point temperature and subsequently reheated. The proposed hybrid system involves simultaneously cooling and dehumidifying the air conveyed to the conditioned ambient in an air-solution membrane contactor. An LiCl solution is cooled by means of a vapour-compression inverse cycle using the refrigerant KLEA 407C. The solution is regenerated in another membrane contactor by exploiting the heat rejected by the condenser. A SIMULINK calculation programme was designed in order to simulate the system under examination in steady-state conditions. The performances of the system were analysed on varying a few significant operating parameters, and were compared with those of a traditional direct-expansion air-conditioning plant in typical summertime conditions. The results of the simulations revealed significant energy savings, which, in particular operating conditions, may exceed 50%. (author)

  8. Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System

    Directory of Open Access Journals (Sweden)

    M. Mujahid Rafique

    2016-04-01

    Full Text Available Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize renewable energy resources. The liquid desiccant-based air conditioning method is pollution free and thermal energy-based cooling techniques can use low grade thermal energy resources like solar energy, waste heat, etc. These systems have an additional advantage of cleaning bacteria and fungi from the air. In this paper, a newly proposed rotary liquid desiccant air conditioning system has been investigated theoretically. Most direct contact liquid desiccant cooling systems have the problem of desiccant carryover which can be eliminated using the proposed system. The effects of various key parameters and climatic conditions on the performance of the system have been evaluated. The results showed that if the key parameters of the system are controlled effectively, the proposed cooling system has the ability to achieve the desired supply air conditions. The system can achieve high coefficient of performance (COP under different conditions. The dehumidifier has a sensible heat ratio (SHR in the range of 0.3–0.6 for different design, climatic, and operating conditions. The system can remove latent load efficiently in applications which require good humidity control.

  9. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo.

    Science.gov (United States)

    Nishimura, Takeshi; Mori, Futoshi; Hanida, Sho; Kumahata, Kiyoshi; Ishikawa, Shigeru; Samarat, Kaouthar; Miyabe-Nishiwaki, Takako; Hayashi, Misato; Tomonaga, Masaki; Suzuki, Juri; Matsuzawa, Tetsuro; Matsuzawa, Teruo

    2016-03-01

    We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD) with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved "Out of Africa" to explore the more severe climates of

  10. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo.

    Directory of Open Access Journals (Sweden)

    Takeshi Nishimura

    2016-03-01

    Full Text Available We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved "Out of Africa" to explore the more

  11. Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

    Directory of Open Access Journals (Sweden)

    Haslinda Mohamed Kamar

    2013-01-01

    Full Text Available This paper presents results of a parametric study performed on an automotive air-conditioning (AAC system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA, on the dry-bulb temperature and specific humidity of the air inside the passengers cabin, and on the evaporator coil cooling load of the AAC system. Results of the parametric study show that increasing the supply air flow rate reduces the dry-bulb temperature of the cabin air, increases both the specific humidity of the air and the evaporator coil load. Increasing the number of occupants in the passenger cabin causes the cabin air temperature, specific humidity and the evaporator coil load to increase. Increasing the vehicle speed causes the specific humidity of the cabin air and the evaporator coil cooling load to increase but the dry-bulb temperature of the air is not significantly affected. Increasing the fractional fresh air intake (XOA also increases the cabin air specific humidity and the evaporator coil cooling load.

  12. System and method for conditioning intake air to an internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Sellnau, Mark C.

    2015-08-04

    A system for conditioning the intake air to an internal combustion engine includes a means to boost the pressure of the intake air to the engine and a liquid cooled charge air cooler disposed between the output of the boost means and the charge air intake of the engine. Valves in the coolant system can be actuated so as to define a first configuration in which engine cooling is performed by coolant circulating in a first coolant loop at one temperature, and charge air cooling is performed by coolant flowing in a second coolant loop at a lower temperature. The valves can be actuated so as to define a second configuration in which coolant that has flowed through the engine can be routed through the charge air cooler. The temperature of intake air to the engine can be controlled over a wide range of engine operation.

  13. The use of air-conditioning to improve performances of personnel; Airco inzet voor betere prestaties

    Energy Technology Data Exchange (ETDEWEB)

    Havenaar, D.

    2012-04-01

    The combination of temperature, air humidity, ventilation and air movement highly determines the comfort feeling of personnel. Moreover, these factors enable optimal performance. Air-conditioning, but particularly temperature control are important instruments in realizing such an optimal performance climate. [Dutch] De combinatie van temperatuur, luchtvochtigheid, luchtverversing en luchtbeweging bepaalt in hoge mate het behaaglijkheidsgevoel van personeel. Daarnaast zorgen deze factoren ervoor dat optimaal gepresteerd kan worden. Om dit optimale prestatieklimaat te realiseren is airconditioning maar vooral temperatuurbeheersing een belangrijk hulpmiddel.

  14. Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Irminger, Philip [ORNL; Rizy, D Tom [ORNL; Li, Huijuan [ORNL; Smith, Travis [ORNL; Rice, C Keith [ORNL; Li, Fangxing [ORNL; Adhikari, Sarina [ORNL

    2012-01-01

    Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

  15. Microwave Disinfection in a Ventilation and Air-Conditioning System

    Institute of Scientific and Technical Information of China (English)

    LU Zhen; ZHANG Ji-li; MA Liang-dong; HE Juan

    2009-01-01

    Because of its broad spectrum and high efficiency,the microwave disinfection was used to control the airborne microbial contaminates in VAC system.Some microwave disinfection devices were developed com-bined with air filter,the design and calculation method was presented,and the disinfection effects on White staphylococcus,Staphylococcus aureus,Bacillus Subtilis,Escherichi coli were measured.The results show that the major influence factors on disinfection effect are microwave power,water-content of filter material,dis-infecting duration.After 15 min,the kill ratio is>90%,and the log value is>1.The microwave field is uni-form and the kill effect of bacteria on each surface of filter is the same,without statistically significant differ-ence.

  16. Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

    2011-01-01

    NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

  17. Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems

    Science.gov (United States)

    Ahearn, D. G.; Simmons, R. B.; Switzer, K. F.; Ajello, L.; Pierson, D. L.

    1991-01-01

    Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

  18. Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems

    Science.gov (United States)

    Ahearn, D. G.; Simmons, R. B.; Switzer, K. F.; Ajello, L.; Pierson, D. L.

    1991-01-01

    Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

  19. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  20. All air treatments are realisable energy efficiently. Room air conditioning based on membranes; Alle Luftbehandlungen energiesparend realisierbar. Membranbasierte Raumklimatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Hannes [ILK Dresden gGmbH, Dresden (Germany). Hauptbereich Luft- und Klimatechnik

    2011-12-15

    Membrane elements for indirect liquid sorption processes enable a decentralized air conditioning. A suitable design of the heat transmitting and substance transmitting components needs to be developed yet. Then, membrane heat exchangers perform a hygienic, condensate-free dehumidification energy efficiently.

  1. Facile route to multi-walled carbon nanotubes under ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hyunchul; Jeong, Soo-Hwan [Kyungpook National University, Daegu (Korea, Republic of)

    2016-02-15

    A facile and practical route is demonstrated to prepare multi-walled carbon nanotubes (MWCNTs) by a sonochemical method. By applying ultrasonic irradiation to the mixture of ferrocene and xylene with small amount of water, crystalline MWCNTs were selectively synthesized under ambient conditions, allowing MWCNTs with diameter of 25-40 nm to be obtained. A control experiment revealed that a small amount of water was essential for producing MWCNTs. The analysis of Raman spectra of MWCNTs showed that the intensity of the D-band relative to the G-band was 0.98, indicating relatively good crystallinity of these MWCNTs. This result was consistent with that of TEM observation.

  2. Numerical simulations of the first operational conditions of the negative ion test facility SPIDER

    Energy Technology Data Exchange (ETDEWEB)

    Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; Agostinetti, P.; Antoni, V.; Baltador, C.; Chitarin, G.; Marconato, N.; Pasqualotto, R.; Sartori, E.; Toigo, V.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Cavenago, M. [INFN-LNL, Viale dell’Università n. 2, 35020 Legnaro (Italy)

    2016-02-15

    In view of the realization of the negative ion beam injectors for ITER, a test facility, named SPIDER, is under construction in Padova (Italy) to study and optimize production and extraction of negative ions. The present paper is devoted to the analysis of the expected first operations of SPIDER in terms of single-beamlet and multiple-beamlet simulations of the hydrogen beam optics in various operational conditions. The effectiveness of the methods adopted to compensate for the magnetic deflection of the particles is also assessed. Indications for a sequence of the experimental activities are obtained.

  3. Method for acquiring part load distribution coefficient of air conditioning system

    Institute of Scientific and Technical Information of China (English)

    丁勇; 李百战; 谭颖

    2009-01-01

    This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizing monthly energy consumption data of the entire year as the analysis object,this paper identifies data distribution,verifies distribution characteristics and analyzes distribution probability density for the issue of running time distribution ratio of air conditioning system in part load zones in the whole operation period,thus providing a basic calculation basis for an overall analysis of energy efficiency of air conditioning system. In view of the general survey of public building energy consumption carried by the government of Chongqing,this paper takes the governmental office building as an example,the part load ratio coefficient corresponding to practical running of air conditioning system of governmental office building in Chongqing is obtained by utilizing the above probability analysis and the solving method of probability density function. By utilizing the ratio coefficient obtained using this method,the part load coefficient with any running ratio of air conditioning system can be obtained according to the requirement of analysis,which can be used in any load ratio for analyzing running energy efficiency of air conditioning system.

  4. Influence of cooling face masks on nasal air conditioning and nasal geometry.

    Science.gov (United States)

    Lindemann, J; Hoffmann, T; Koehl, A; Walz, E M; Sommer, F

    2017-06-01

    Nasal geometries and temperature of the nasal mucosa are the primary factors affecting nasal air conditioning. Data on intranasal air conditioning after provoking the trigeminal nerve with a cold stimulus simulating the effects of an arctic condition is still missing. The objective was to investigate the influence of skin cooling face masks on nasal air conditioning, mucosal temperature and nasal geometry. Standardized in vivo measurements of intranasal air temperature, humidity and mucosal temperature were performed in 55 healthy subjects at defined detection sites before and after wearing a cooling face mask. Measurements of skin temperature, rhinomanometry and acoustic rhinometry were accomplished. After wearing the face mask the facial skin temperature was significantly reduced. Intranasal air temperature did not change. Absolute humidity and mucosal temperature increased significantly. The acoustic rhinometric results showed a significant increase of the volumes and the cross-sectional areas. There was no change in nasal airflow. Nasal mucosal temperature, humidity of inhaled air, and volume of the anterior nose increased after application of a cold face mask. The response is mediated by the trigeminal nerve. Increased mucosal temperatures as well as changes in nasal geometries seem to guarantee sufficient steady intranasal nasal air conditioning.

  5. Preoperational Subsurface Conditions at the Idaho Nuclear Technology and Engineering Center Service Wastewater Discharge Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ansley, Shannon L.

    2002-02-20

    The Idaho Nuclear Technology and Engineering Center (INTEC) Service Wastewater Discharge Facility replaces the existing percolation ponds as a disposal facility for the INTEC Service Waste Stream. A preferred alternative for helping decrease water content in the subsurface near INTEC, closure of the existing ponds is required by the INTEC Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Record of Decision (ROD) for Waste Area Group 3 Operable Unit 3-13 (DOE-ID 1999a). By August 2002, the replacement facility was constructed approximately 2 miles southwest of INTEC, near the Big Lost River channel. Because groundwater beneath the Idaho National Engineering and Environmental Laboratory (INEEL) is protected under Federal and State of Idaho regulations from degradation due to INEEL activities, preoperational data required by U.S. Department of Energy (DOE) Order 5400.1 were collected. These data include preexisting physical, chemical, and biological conditions that could be affected by the discharge; background levels of radioactive and chemical components; pertinent environmental and ecological parameters; and potential pathways for human exposure or environmental impact. This document presents specific data collected in support of DOE Order 5400.1, including: four quarters of groundwater sampling and analysis of chemical and radiological parameters; general facility description; site specific geology, stratigraphy, soils, and hydrology; perched water discussions; and general regulatory requirements. However, in order to avoid duplication of previous information, the reader is directed to other referenced publications for more detailed information. Documents that are not readily available are compiled in this publication as appendices. These documents include well and borehole completion reports, a perched water evaluation letter report, the draft INEEL Wellhead Protection Program Plan, and the Environmental Checklist.

  6. Preoperational Subsurface Conditions at the Idaho Nuclear Technology and Engineering Center Service Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ansley, Shannon Leigh

    2002-02-01

    The Idaho Nuclear Technology and Engineering Center (INTEC) Service Wastewater Discharge Facility replaces the existing percolation ponds as a disposal facility for the INTEC Service Waste Stream. A preferred alternative for helping decrease water content in the subsurface near INTEC, closure of the existing ponds is required by the INTEC Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Record of Decision (ROD) for Waste Area Group 3 Operable Unit 3-13 (DOE-ID 1999a). By August 2002, the replacement facility was constructed approximately 2 miles southwest of INTEC, near the Big Lost River channel. Because groundwater beneath the Idaho National Engineering and Environmental Laboratory (INEEL) is protected under Federal and State of Idaho regulations from degradation due to INEEL activities, preoperational data required by U.S. Department of Energy (DOE) Order 5400.1 were collected. These data include preexisting physical, chemical, and biological conditions that could be affected by the discharge; background levels of radioactive and chemical components; pertinent environmental and ecological parameters; and potential pathways for human exposure or environmental impact. This document presents specific data collected in support of DOE Order 5400.1, including: four quarters of groundwater sampling and analysis of chemical and radiological parameters; general facility description; site specific geology, stratigraphy, soils, and hydrology; perched water discussions; and general regulatory requirements. However, in order to avoid duplication of previous information, the reader is directed to other referenced publications for more detailed information. Documents that are not readily available are compiled in this publication as appendices. These documents include well and borehole completion reports, a perched water evaluation letter report, the draft INEEL Wellhead Protection Program Plan, and the Environmental Checklist.

  7. Greenhouse Gas Reporting Requirements Related to Stationary Refrigeration and Air Conditioning

    Science.gov (United States)

    Provides links to information about parts of the 2009 Mandatory Reporting of Greenhouse Gases Rule that are relevant to owners and importers of stationary refrigeration and air-conditioning equipment.

  8. Transitioning to Low-GWP Alternatives in Motor Vehicle Air Conditioning Systems

    Science.gov (United States)

    This fact sheet provides information on low-GWP alternatives in newly manufactured motor vehicle air conditioning systems. It discusses HFC alternatives, market trends, challenges to market entry for alternatives, and potential solutions.

  9. Transitioning to Low-GWP Alternatives in Residential and Commercial Air Conditioning

    Science.gov (United States)

    This fact sheet provides information on low-GWP alternatives in newly manufactured residential and commercial air conditioning systems. It discusses HFC alternatives, market trends, challenges to market entry for alternatives, and potential solutions.

  10. Transitioning to Low-GWP Alternatives in Residential and Light Commercial Air Conditioning

    Science.gov (United States)

    This fact sheet provides current information on low global warming potential (GWP) alternatives for new equipment in residential and light commercial air conditioning (AC), in lieu of high-GWP hydrofluorocarbons (HFCs).

  11. Fuel Savings and Emission Reductions from Next-Generation Mobile Air Conditioning Technology in India: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Chaney, L.; Thundiyil, K.; Chidambaram, S.; Abbi, Y. P.; Anderson, S.

    2007-05-01

    This paper quantifies the mobile air-conditioning fuel consumption of the typical Indian vehicle, exploring potential fuel savings and emissions reductions these systems for the next generation of vehicles.

  12. Influences of the Indoor Environment on Heat, Air, and Moisture Conditions in the Component

    DEFF Research Database (Denmark)

    Steskens, Paul Wilhelmus Maria Hermanus; Rode, Carsten; Janssen, Hans

    2008-01-01

    Current models to predict heat, air and moisture (HAM) conditions in building components assume uniform boundary conditions, both for the temperature and relative humidity of the air in an indoor space as well as for the heat and moisture surface transfer coefficients. The heat and moisture surface...... transfer coefficients strongly depend on the local air velocity, local temperature, water-material interactions, water content at the material surface, and the surface texture of the material. Moreover, due to local heat and moisture sources, imperfect mixing and microclimatic effects, temperature...... and relative humidity in the adjacent air are seldom uniform. In order to obtain a reliable prediction of the HAM conditions in a building component, an accurate description of the indoor (and outdoor) boundary conditions is required. The objective of the present paper is to analyze the influence...

  13. Evaluating Membrane Processes for Air Conditioning; Highlights in Research and Development, NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-06-01

    This NREL Highlight discusses a recent state-of-the-art review of membrane processes for air conditioning that identifies future research opportunities. This highlight is being developed for the June 2015 S&T Alliance Board meeting.

  14. Air conditioning management of huge rooms; Gestion climatique des locaux de grande dimension

    Energy Technology Data Exchange (ETDEWEB)

    Guitton, P. [Electricite de France (EDF), 78 - Chatou (France); Izard, J.L. [Ecole d`Architecture de Marseille-Luminy, 13 - Marseille-Luminy (France); Wurtz, E. [La Rochelle Universite, 17 - La Rochelle, LEPTAB (France)] [and others

    1999-09-01

    This conference was organized by the section `air-conditioning engineering` of the French society of thermal engineers (SFT). This document comprises the abridged versions of the communications and deals with: air-conditioning using displacement: experience feedback on tertiary applications and development of a dimensioning tool, thermal response of linear atria, application of the zonal method to the description of the temperature field and flows pattern inside an auditorium, theoretical and experimental study of air renewal inside industrial rooms, management of huge rooms, design of new optimized buildings and use of the TAS software, can TRNSYS and Comis codes be used for huge spaces?, experimental study of the thermal-aeraulic conditions generated by a displacement air-conditioning device. (J.S.)

  15. Temperature and humidity independent control (THIC) of air-conditioning system

    CERN Document Server

    Liu, Xiaohua; Zhang, Tao

    2014-01-01

    This book presents the main components of the Temperature and Humidity Independent Control (THIC) of air-conditioning systems, including dehumidification devices, high-temperature cooling devices and indoor terminal devices.

  16. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  17. New Energy-Efficient Electromagnetic Clutch for Automotive Air Conditioning Compressors

    OpenAIRE

    Baumgart, Rico; van der Seylberg, Frank; Aurich, Joerg; von Unwerth, Thomas

    2012-01-01

    Even if the air conditioning is switched off, the internal combustion engine in today’s cars continues to drive the common compressor. To avoid resulting power losses, the automotive industry aspires to apply electromagnetic clutches. When the air conditioning is used, however, CO2-emission increases significantly because the electromag-netic coil consumes electricity. The CO2-reduction per year is consequently very low, which is why new compressor clutches were developed that do not require ...

  18. Refrigeration, heating and air conditioning pocket book 2012; Kaelte, Waerme, Klima. Taschenbuch 2012

    Energy Technology Data Exchange (ETDEWEB)

    Schaedlich, Sylvia (ed.)

    2011-07-01

    The refrigeration, heating and air conditioning pocket book 2012 contains a calendar of important events and technical fairs. A publication of this type requires constant updating, and this is what was done in this pocket book. The technical documentation contains the following aspects: General working basis; special working basis of refrigeration; coolants; refrigeration; air-conditioning technology; heating technology; measurement and control technology; general information.

  19. 78 FR 40015 - Approval and Promulgation of State Air Quality Plans for Designated Facilities and Pollutants...

    Science.gov (United States)

    2013-07-03

    ... Pollutants; District of Columbia; Control of Emissions From Existing Hospital/Medical/Infectious Waste... taking direct final action to approve a negative declaration for hospital/medical/infectious waste... pollutants) at existing solid waste combustor facilities (designated facilities) whenever standards...

  20. Clean air with positive energy balance. Elisabeth hospital in Essen uses energy optimized air conditioning systems; Saubere Luft mit positiver Energiebilanz. Elisabeth-Krankenhaus in Essen nutzt energieoptimierte Lueftungsgeraete

    Energy Technology Data Exchange (ETDEWEB)

    Dunker, Ralf

    2009-02-15

    Thinking on a long-term basis, spontaneously acting - according to this slogan the Elizabeth hospital in Essen (Federal Republic of Germany) converts potentials of energy saving with the facility management. Parallel to the change of the endoscope department and the station Barbara with its 35 beds, the hospital had installed particularly energy-saving air conditioning systems which can be cleaned easily. A view behind the doors of the technology rooms.

  1. Influences of the Indoor Environment on Heat, Air and Moisture Conditions in The Building Component: Boundary Conditions Modeling

    DEFF Research Database (Denmark)

    Steskens, Paul Wilhelmus Maria Hermanus; Rode, Carsten; Janssen, Hans

    2008-01-01

    used to investigate this influence. The research showed that the indoor environmental conditions and local airflow velocity have a relatively large influence on the predicted HAM conditions in a building component. The influence of the convective surface heat transfer coefficient on the HAM performance...... is not acceptable for the convective surface heat transfer coefficient. The study showed that the influence on the surface relative humidity is limited.......Current models to predict heat, air and moisture (HAM) conditions in building components assume uniform boundary conditions, both for the temperature and relative humidity of the air in an indoor space as well as for the surface transfer coefficients. Such models cannot accurately predict the HAM...

  2. The new exchangers in refrigeration and air, conditioning applications

    Energy Technology Data Exchange (ETDEWEB)

    Marvillet, Ch. [CEA, 38 - Grenoble (France). GRETh

    1997-12-31

    The investigation carried out by the `heat exchangers` network has revealed a number of points which should be noted here at the beginning of this presentation. It has been observed that most of today`s products (fin and tube heat exchangers) are designed along traditional lines. However despite this `conservatism`, a lot of attention is found on the technical and innovative techniques used in other areas of the world (particularly in Japan). Moreover, some of these innovative techniques (micro fin tubes, louvered fins) tend to be more frequently applied than others, and their gradual introduction into products which are `made in the EEC` is to be expected. The purpose of this paper is to respond, at least partially, to the interest shown by the industries contacted. during this investigation in these new techniques. In the first chapter, an overview of the information available today on high performance thermal heat exchange surfaces will be given. Micro-fin tubes and louvered fins will be the two surfaces considered in the first part of this document. According to this investigation, the fin and tube heat exchanger remains the only product available today for evaporating and condensing refrigerant applications using air as the fluid to be treated. Other technological solutions exist, however; brazed fin and plate heat exchangers commonly used in applications where compactness is an essential quality will be examined in the second part of this document. Moreover, the use of fluids which will replace CFCS in the years to come, and the possible comeback of ammonia will certainly have consequences on the design of evaporators and condensers. In the third part of this document the effects of these changes on fin and tube heat exchangers will be evaluated, and the first published results of the use of substitution fluids will be discussed. (author) 16 refs.

  3. A comparative study on the metering accuracy for given installation conditions of metering facility

    Energy Technology Data Exchange (ETDEWEB)

    Her, Jae Young; Lee, Seung Jun; Ha, Young Cheol; Ahn, Seung Hee; Lee, Cheol Gu [R and D Center, Korea Gas Co., (Korea)

    1999-12-01

    The object of this study is to improve metering facilities of Korea Gas Corporation(KOGAS) metering station which are being operated in unfavorable straight pipe length condition (metropolitan area). For experiment, a test facilities was modeled based on Dogsan metering station (one of KOGAS metering stations) which has the most unfavorable conditions in metropolitan area. The test facilities was set up in Jungdong metering station (one of KOGAS metering stations) supplying natural gas to a power plant and city gas companies. The tests were performed with flowconditioner which was installed in the former straight pipe of a turbine meter and an Orifice meter, and the tests keep going with changing both diameter ratio({beta} = d/D) and flowrate(Q{sub v}). In other words, the tests were performed according to flowrate change for fixed diameter ratio. After the test was completed, the diameter ratio was increased by 0.1 and the same procedures were conducted again. The test was conducted for diameter ratio from 0.3 to 0.7. For Orifice meter, the error showed 0.4 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and 0.8 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. For Turbine meter, the error showed -0.5 %(Test maximum flowrate=3,030 Nm{sup 3}/h) and -0.1 %(Test maximum flowrate=9,204 Nm{sup 3}/h) for {beta}=0.3 and 0.7, respectively. 44 refs., 32 figs., 27 tabs.

  4. Contribution of air conditioning adoption to future energy use under global warming.

    Science.gov (United States)

    Davis, Lucas W; Gertler, Paul J

    2015-05-12

    As household incomes rise around the world and global temperatures go up, the use of air conditioning is poised to increase dramatically. Air conditioning growth is expected to be particularly strong in middle-income countries, but direct empirical evidence is scarce. In this paper we use high-quality microdata from Mexico to describe the relationship between temperature, income, and air conditioning. We describe both how electricity consumption increases with temperature given current levels of air conditioning, and how climate and income drive air conditioning adoption decisions. We then combine these estimates with predicted end-of-century temperature changes to forecast future energy consumption. Under conservative assumptions about household income, our model predicts near-universal saturation of air conditioning in all warm areas within just a few decades. Temperature increases contribute to this surge in adoption, but income growth by itself explains most of the increase. What this will mean for electricity consumption and carbon dioxide emissions depends on the pace of technological change. Continued advances in energy efficiency or the development of new cooling technologies could reduce the energy consumption impacts. Similarly, growth in low-carbon electricity generation could mitigate the increases in carbon dioxide emissions. However, the paper illustrates the enormous potential impacts in this sector, highlighting the importance of future research on adaptation and underscoring the urgent need for global action on climate change.

  5. Ice Storage Air-Conditioning System Simulation with Dynamic Electricity Pricing: A Demand Response Study

    Directory of Open Access Journals (Sweden)

    Chi-Chun Lo

    2016-02-01

    Full Text Available This paper presents an optimal dispatch model of an ice storage air-conditioning system for participants to quickly and accurately perform energy saving and demand response, and to avoid the over contact with electricity price peak. The schedule planning for an ice storage air-conditioning system of demand response is mainly to transfer energy consumption from the peak load to the partial-peak or off-peak load. Least Squares Regression (LSR is used to obtain the polynomial function for the cooling capacity and the cost of power consumption with a real ice storage air-conditioning system. Based on the dynamic electricity pricing, the requirements of cooling loads, and all technical constraints, the dispatch model of the ice-storage air-conditioning system is formulated to minimize the operation cost. The Improved Ripple Bee Swarm Optimization (IRBSO algorithm is proposed to solve the dispatch model of the ice storage air-conditioning system in a daily schedule on summer. Simulation results indicate that reasonable solutions provide a practical and flexible framework allowing the demand response of ice storage air-conditioning systems to demonstrate the optimization of its energy savings and operational efficiency and offering greater energy efficiency.

  6. Air-side performance of a micro-channel heat exchanger in wet surface conditions

    Directory of Open Access Journals (Sweden)

    Srisomba Raviwat

    2017-01-01

    Full Text Available The effects of operating conditions on the air-side heat transfer, and pressure drop of a micro-channel heat exchanger under wet surface conditions were studied experimentally. The test section was an aluminum micro-channel heat exchanger, consisting of a multi-louvered fin and multi-port mini-channels. Experiments were conducted to study the effects of inlet relative humidity, air frontal velocity, air inlet temperature, and refrigerant temperature on air-side performance. The experimental data were analyzed using the mean enthalpy difference method. The test run was performed at relative air humidities ranging between 45% and 80%; air inlet temperature ranges of 27, 30, and 33°C; refrigerant-saturated temperatures ranging from 18 to 22°C; and Reynolds numbers between 128 and 166. The results show that the inlet relative humidity, air inlet temperature, and the refrigerant temperature had significant effects on heat transfer performance and air-side pressure drop. The heat transfer coefficient and pressure drop for the micro-channel heat exchanger under wet surface conditions are proposed in terms of the Colburn j factor and Fanning f factor.

  7. Influence of Ventilation Ratio on Desiccant Air Conditioning System's Efficiency Performance

    Science.gov (United States)

    Tran, Thien Nha; Akisawa, Atsushi; Kashiwagi, Takao; Hamamoto, Yoshinori

    Ventilation air is a concern for engineers since ventilated air controls indoor air contamination; additional ventilation, however, increases the energy consumption of buildings. The study investigates the energy efficiency performance of the desiccant dehumidification air conditioning system in the context of ventilation for a hot-humid climate such as summer in Japan. The investigation focuses on the variable ratio of ventilation air as required by the application of air conditioning system. The COP of the desiccant air conditioning system is determined. The evaluation is subsequently performed by comparing the desiccant based system with the conventional absorption cooling system and the vapor compression cooling system. Based on 12 desiccant rotor simulations, it is found that the desiccant regeneration temperature required varies between 47°C to 85°C as ventilation ratio increases from 0. 0 to 100%, and up to 52. 5°C as the ventilation ratio achieves 14%. The heat required for regenerating desiccant accounts for 55% and higher of the system's total heat consumption; the system is expected to be energy efficient by using wasted heat from the absorption chiller for desiccant regeneration; and its energy efficiency expands as the ratio of ventilation air rises above 15% compared with the conventional absorption cooling system. The energy efficiency also benefits as the ratio rises beyond 70% against the conventional vapor compression cooling system.

  8. How to improve the irradiation conditions for the International Fusion Materials Irradiation Facility

    CERN Document Server

    Daum, E

    2000-01-01

    The accelerator-based intense D-Li neutron source International Fusion Materials Irradiation Facility (IFMIF) provides very suitable irradiation conditions for fusion materials development with the attractive option of accelerated irradiations. Investigations show that a neutron moderator made of tungsten and placed in the IFMIF test cell can further improve the irradiation conditions. The moderator softens the IFMIF neutron spectrum by enhancing the fraction of low energy neutrons. For displacement damage, the ratio of point defects to cascades is more DEMO relevant and for tritium production in Li-based breeding ceramic materials it leads to a preferred production via the sup 6 Li(n,t) sup 4 He channel as it occurs in a DEMO breeding blanket.

  9. Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System

    Institute of Scientific and Technical Information of China (English)

    SU Shun-yu; ZHANG Chun-zhi; CHEN Jian

    2009-01-01

    This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-con-ditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of dif-ferent refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-eonditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump-The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.

  10. Investigation on regeneration and energy storage characteristics of a solar liquid desiccant air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    SHI Mingheng; DU Bin; ZHAO Yun

    2007-01-01

    Solar liquid desiccant air-conditioner is a new air-conditioning system in which liquid desiccant can be regenerated by solar energy and energy can be stored in the form of chemical energy in the liquid desiccant.In this paper regeneration and energy storage characteristics were studied theoretically and experimentally.Two criterion equations for heat and mass transfer in the regeneration process were obtained.The main factors that influence the regeneration process were analyzed.A principal solar liquid desiccant air-conditioning system under energy storage operating mode is proposed.

  11. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor

    2014-01-01

    was evaluated as deodorant materials neutralising ammonia in air. The deodorant material efficiency was tested in a special experimental set-up consisting of a straight pipe section, an ammonia gas generator, a fan and a textile frame. The deodorant materials, placed in the pipe, were exposed to a flow of air...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity....... The porous activated carbon fiber fabric did not have a deodorant effect....

  12. Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

    Energy Technology Data Exchange (ETDEWEB)

    Sondrup, Andrus Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-10-01

    The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i

  13. A model of airflow in the nasal cavities: Implications for nasal air conditioning and epistaxis.

    Science.gov (United States)

    Bailie, Neil; Hanna, Brendan; Watterson, John; Gallagher, Geraldine

    2009-01-01

    A friction force is generated when moving air contacts the nasal walls, referred to as wall shear stress. This interaction facilitates heat and mass transfer between the mucosa and air, i.e., air-conditioning. The objective of this research was to study the distribution of wall shear stress within the nasal cavity to identify areas that contribute significantly to air-conditioning within the nasal cavity. Three-dimensional computational models of the nasal airways of five healthy subjects (three male and two female subjects) were constructed from nasal CT scans. Numerical simulations of nasal airflow were conducted using the commercial computational fluid dynamics code Fluent 6 (Ansys, Inc., Canonsburg, PA). Wall shear stress was derived from the numerical simulation. Air-conditioning was simulated to confirm the relationship with wall shear stress. Nasal airflow simulations predicted high wall shear stress along the anterior aspect of the inferior turbinate, the anteroinferior aspect of the middle turbinate, and within Little's area. The airflow simulations indicate that the inferior and middle turbinates and Little's area on the anterior nasal septum contribute significantly to nasal air-conditioning. The concentration of wall shear stress within Little's area indicates a desiccating and potentially traumatic effect of inhaled air that may explain the predilection for spontaneous epistaxis at this site.

  14. Silver zeolite antimicrobial activity in aluminium heating, ventilation and air conditioning system ducts.

    Science.gov (United States)

    Rizzetto, R; Mansi, A; Panatto, D; Rizzitelli, E; Tinteri, C; Sasso, T; Gasparini, R; Crovari, P

    2008-03-01

    Air pollution in confined environments is a serious health problem, in that most people spend long periods indoors (in homes, offices, classrooms etc.). Some people (children, the elderly, heart disease patients, asthmatic or allergic subjects) are at greater risk because of their conditions of frailty. The growing use of air-conditioning systems in many public and private buildings aggravates this health risk, especially when these systems are not correctly installed or regularly serviced. The aim of our study was to verify the capacity of Ag+ ions to stop the growth of bacteria and moulds inside the ducts of Heating, Ventilation and Air Conditioning system ducts (HVAC) systems when these ducts were lined with active Ag+ ions zeolite-coated panels. A Y-shaped HVAC model with two branches was used; one branch was made of traditional galvanized iron, as was the whole system, while the other was lined with active Ag+ zeolite-coated polyurethane panels. During the test, samples of dust present inside both ducts were collected and seeded in liquid and solid media to detect bacteria and moulds. The presence of bacteria was also sought in the air emerging from the outlets of both ducts. Tests made on samples of particulate collected from the two different ducts revealed a lower total bacterial load in the samples collected from the Ag+ zeolite-coated duct than in the samples from the traditional Zn galvanized duct. In addition, the values of bacterial load found in the air emerging from the Ag+ ions zeolite-lined duct were 5 times lower than those found in the air from the traditional galvanized iron duct. The utilization of Ag+ zeolite-coated panels in air-conditioning systems could improve the quality of the emerging air in comparison with traditional installations in galvanized iron. This innovation could prove particularly advantageous in the event of accidents during the installation of air-conditioning systems or of contaminated aerosols coming from outside.

  15. Modeling validation and control analysis for controlled temperature and humidity of air conditioning system.

    Science.gov (United States)

    Lee, Jing-Nang; Lin, Tsung-Min; Chen, Chien-Chih

    2014-01-01

    This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14 °C, 0006 kg(w)/kg(da) in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  16. Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-01-01

    Full Text Available This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14°C, 0006 kgw/kgda in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  17. Influences of the Indoor Environment on Heat, Air, and Moisture Conditions in the Component

    DEFF Research Database (Denmark)

    Steskens, Paul Wilhelmus Maria Hermanus; Rode, Carsten; Janssen, Hans

    2008-01-01

    Current models to predict heat, air and moisture (HAM) conditions in building components assume uniform boundary conditions, both for the temperature and relative humidity of the air in an indoor space as well as for the heat and moisture surface transfer coefficients. The heat and moisture surface...... and relative humidity in the adjacent air are seldom uniform. In order to obtain a reliable prediction of the HAM conditions in a building component, an accurate description of the indoor (and outdoor) boundary conditions is required. The objective of the present paper is to analyze the influence...... of the variations of the surface transfer coefficients near the surface of a building component on the HAM conditions in the component. A parameter study has been used to investigate this influence. The research showed that the surface transfer coefficients have a relatively large influence on the redicted HAM...

  18. Final Environmental Assessment: For Immediate Storm Surge Protection for Santa Rosa Island Facilities, Eglin Air Force Base, FL

    Science.gov (United States)

    2006-06-01

    allowable atmospheric concentration that may occur and still protect public health and welfare with a reasonable margin of safety. The NAAQS...federal agencies to make every effort to reduce the risk of flood loss, minimize the impact of floods on human health, safety, and welfare , and preserve...Protection for Santa Rosa Island Facilities, Eglin Air Force Base, FL Davis et al., 2000 Davis, R. W., W. E. Evans, B. Würsig (eds), 2000. Cetaceans

  19. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems.

    Science.gov (United States)

    Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun

    2017-01-01

    The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.

  20. 复合式空调系统空调期特性的模拟研究%Air conditioning period characteristic simulation of compound air conditioning system

    Institute of Scientific and Technical Information of China (English)

    齐卫阳; 王令; 胥海伦; 钟星灿

    2012-01-01

    针对不同地区的水文地质条件和气象参数,运用SES软件对复合式空调系统进行了数值模拟.运用曲线拟合方法总结了温度临界点的经验公式并且对影响空调期的各因素进行了定性分析.通过正交试验对影响空调期的各因素进行了显著性评价.%For different hydrogeologic conditions and meteorological parameters in different regions, carries out numerical simulation of the compound air conditioning system based on SES software. Summaries the empirical formula of critical point temperature and performs a qualitative analysis of affecting factors of air conditioning period using the curve fitting method. An orthogonal test is made to evaluate the significance of affecting factors of the air conditioning period.

  1. Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

    Science.gov (United States)

    Simmons, R B; Crow, S A

    1995-01-01

    New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

  2. Building Air Quality Guide: A Guide for Building Owners and Facility Managers

    Science.gov (United States)

    The Building Air Quality, developed by the EPA and the National Institute for Occupational Safety and Health, provides practical suggestions on preventing, identifying, and resolving indoor air quality (IAQ) problems in public and commercial buildings.

  3. Design and performance of a solar-powered air-conditioning system in a green building

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, X.Q.; Wang, R.Z.; Wu, J.Y.; Dai, Y.J.; Ma, Q. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2008-05-15

    A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered air-conditioning system was 15.3 kW during an 8 h operation and the maximum value exceeded 20 kW. Solar fraction for the system in summer was 71.7%, which corresponded to the designed cooling load (15 kW). Compared with the ambient temperature, it was deduced that solar radiant intensity had a more distinct influence on the performance of solar-powered air-conditioning system. (author)

  4. Improving forecast skill by assimilation of quality-controlled AIRS temperature retrievals under partially cloudy conditions

    Science.gov (United States)

    Reale, O.; Susskind, J.; Rosenberg, R.; Brin, E.; Liu, E.; Riishojgaard, L. P.; Terry, J.; Jusem, J. C.

    2008-04-01

    The National Aeronautics and Space Administration (NASA) Atmospheric Infrared Sounder (AIRS) on board the Aqua satellite is now recognized as an important contributor towards the improvement of weather forecasts. At this time only a small fraction of the total data produced by AIRS is being used by operational weather systems. In fact, in addition to effects of thinning and quality control, the only AIRS data assimilated are radiance observations of channels unaffected by clouds. Observations in mid-lower tropospheric sounding AIRS channels are assimilated primarily under completely clear-sky conditions, thus imposing a very severe limitation on the horizontal distribution of the AIRS-derived information. In this work it is shown that the ability to derive accurate temperature profiles from AIRS observations in partially cloud-contaminated areas can be utilized to further improve the impact of AIRS observations in a global model and forecasting system. The analyses produced by assimilating AIRS temperature profiles obtained under partial cloud cover result in a substantially colder representation of the northern hemisphere lower midtroposphere at higher latitudes. This temperature difference has a strong impact, through hydrostatic adjustment, in the midtropospheric geopotential heights, which causes a different representation of the polar vortex especially over northeastern Siberia and Alaska. The AIRS-induced anomaly propagates through the model's dynamics producing improved 5-day forecasts.

  5. Improving Forecast Skill by Assimilation of Quality-controlled AIRS Temperature Retrievals under Partially Cloudy Conditions

    Science.gov (United States)

    Reale, O.; Susskind, J.; Rosenberg, R.; Brin, E.; Riishojgaard, L.; Liu, E.; Terry, J.; Jusem, J. C.

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Atmospheric Infrared Sounder (AIRS) on board the Aqua satellite has been long recognized as an important contributor towards the improvement of weather forecasts. At this time only a small fraction of the total data produced by AIRS is being used by operational weather systems. In fact, in addition to effects of thinning and quality control, the only AIRS data assimilated are radiance observations of channels unaffected by clouds. Observations in mid-lower tropospheric sounding AIRS channels are assimilated primarily under completely clear-sky conditions, thus imposing a very severe limitation on the horizontal distribution of the AIRS-derived information. In this work it is shown that the ability to derive accurate temperature profiles from AIRS observations in partially cloud-contaminated areas can be utilized to further improve the impact of AIRS observations in a global model and forecasting system. The analyses produced by assimilating AIRS temperature profiles obtained under partial cloud cover result in a substantially colder representation of the northern hemisphere lower midtroposphere at higher latitudes. This temperature difference has a strong impact, through hydrostatic adjustment, in the midtropospheric geopotential heights, which causes a different representation of the polar vortex especially over northeastern Siberia and Alaska. The AIRS-induced anomaly propagates through the model's dynamics producing improved 5-day forecasts.

  6. Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility based on a medical cyclotron

    Science.gov (United States)

    Giardina, M.; Tomarchio, E.; Greco, D.

    2015-11-01

    Positron emitting radionuclides are increasingly used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. During the process of production and/or patient administration of radiopharmaceuticals, an amount of these radionuclides might become airborne and escape into the environment. Therefore, the analysis of radionuclide concentration in the air released to the stack is a very important issue to evaluate the dose to the population living around the plant. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceuticals production, must be routinely carried out with an automatic measurement system. In this work is presented the air monitoring system realized at "San Gaetano" NMC at Bagheria (Italy) besides the analysis of the recorded stack relesead air concentration data. Sampling of air was carried out continuously and gamma-ray spectrometric measurement are made on-line and for a short time by using a shielded Marinelli beaker filled with sampled air and a gamma detector. The use of this system allows to have 1440 values of air concentration per day from 2002, year of the start of operation with the cyclotron. Therefore, the concentration values are very many and an analysis software is needed to determine the dose to the population. A comparison with the results of a simulation code based on a Gaussian Plume air dispersion modelling allow us to confirm the no-radiological significance of the stack effluent releases in terms of dose to population and to evaluate possible improvements in the plant devices to reduce the air concentration at stack.

  7. Radiation damage parameters for modelling of FRM irradiation conditions at the RADEX facility of INR RAS

    CERN Document Server

    Koptelov, E A; Sobolevsky, N M; Strebkov, Y S; Subbotin, A V

    2002-01-01

    Results of MC calculations of primary radiation damage generated by the intense proton beam at the RADiation EXperiment (RADEX) facility of the Institute for Nuclear Research, Russian Academy of Sciences (INR RAS) are presented. RADEX is the irradiation channel located inside a proton target at the beam stop of the INR RAS linear proton accelerator having energy up to 600 MeV. The position of the irradiation channel at the facility can be changed by rotation of the proton target relative to the vertical axis, thus varying the relative influence of the primary protons and spallation neutrons on the primary damage kinetics. By shifting the proton target position outside the horizontal beam axis, one may reduce the predominant input of high-energy protons to the irradiation field. As a result, the spectrum of primary knock-on atoms in the irradiated sample may be significantly softened. This gives the possibility of changing irradiation parameters to simulate irradiation conditions at other installations (ITER a...

  8. Model Based Sensor System for Temperature Measurement in R744 Air Conditioning Systems

    CERN Document Server

    Reitz, Sven; Schneider, Peter

    2008-01-01

    The goal is the development of a novel principle for the temperature acquisition of refrigerants in CO2 air conditioning systems. The new approach is based on measuring the temperature inside a pressure sensor, which is also needed in the system. On the basis of simulative investigations of different mounting conditions functional relations between measured and medium temperature will be derived.

  9. Dynamic Analysis of Condenser Assembly of Automobile Air Conditioning System Using CAE Tools

    Science.gov (United States)

    Singh, M.; Singh, D.; Saini, J. S.

    2013-04-01

    With the automotive air-conditioning industry aiming at higher levels of quality, cost effectiveness and a short time to market, the need for simulation is at an all time high. In the present work, the use of dynamics analysis is proposed in the simulation of the automobile air conditioning condenser assembly for the vibration loads. The condenser assembly has been analyzed using the standard testing conditions. The results revealed that the components of condenser assembly may fail due to resonance in dynamic analysis. Thereafter, the condenser assembly was optimized, resulting in a 2 % reduction in mass.

  10. Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station

    Institute of Scientific and Technical Information of China (English)

    LI Wei; NA Yanling

    2007-01-01

    Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.

  11. AN EXPERIMENTAL ANALYSIS OF THE EFFECT OF REFRIGERANT CHARGE LEVEL AND OUTDOOR CONDITION ON A WINDOW AIR CONDITIONER

    Directory of Open Access Journals (Sweden)

    M Herbert Raj

    2010-01-01

    Full Text Available R22 is an hydrochlorofluorocarbon widely used in refrigerant and air conditioning plants and although it has a low ozone depletion potential (0.05, it is necessary to consider the large amount that commonly escapes from commercial units to the atmosphere. This paper presents experimental investigation on the performance of a window air conditioner operated with R22 and the M20 (80% R407C and 20% HC blend by wt. refrigerant mixture tested under different refrigerant charge levels and outdoor conditions. Experiments were conducted in accordance with the Bureau of Indian standards procedure in a psychrometric test facility. Capillary and charge optimization tests were conducted for the both R22 and the M20 refrigerant mixture based on maximum coefficient of performance. Refrigerant charge in the air conditioner was systematically varied and the influences of refrigerant charge quantities and outdoor conditions on system performance are studied for both R22 and the M20 refrigerant mixture. At each charge levels, the outdoor room conditions were changed in accordance with Bureau of Indian standards. It is observed that R22 is more sensitive to deviations in charge levels as compared to the M20 refrigerant mixture. A decrease in charge level of about 7% reduced the system refrigerating capacity by 11.3% with R22 while with the M20 refrigerant mixture it reduces by 6.9% only. Similarly an over charge by 7% reduces the refrigerating capacity of the system by 13.8% with R22 while with M20 it reduces by 6.5% only.

  12. Thermal comfort conditions in the NBS/DoE direct gain passive solar test facility

    Science.gov (United States)

    Liu, S. T.

    1982-12-01

    The thermal comfort conditions in a direct gain cell of passive solar test facility were analyzed. It was found that the daytime operative temperature as measured by the black globe temperature sensors in an area near the large south glazing exceeded the upper boundary of the ASHRAE comfort envelope by a large amount in a clear day during both the thermal transition month of October and the cold winter month of January. The reflected solar radiation from the interior surfaces and the snow covered ground plays a significant role on the measured black globe temperature and should be included in the computation of the mean radiant temperature for a space with large glazed areas.

  13. Impact of emissions from natural gas production facilities on ambient air quality in the Barnett Shale area: a pilot study.

    Science.gov (United States)

    Zielinska, Barbara; Campbell, Dave; Samburova, Vera

    2014-12-01

    Rapid and extensive development of shale gas resources in the Barnett Shale region of Texas in recent years has created concerns about potential environmental impacts on water and air quality. The purpose of this study was to provide a better understanding of the potential contributions of emissions from gas production operations to population exposure to air toxics in the Barnett Shale region. This goal was approached using a combination of chemical characterization of the volatile organic compound (VOC) emissions from active wells, saturation monitoring for gaseous and particulate pollutants in a residential community located near active gas/oil extraction and processing facilities, source apportionment of VOCs measured in the community using the Chemical Mass Balance (CMB) receptor model, and direct measurements of the pollutant gradient downwind of a gas well with high VOC emissions. Overall, the study results indicate that air quality impacts due to individual gas wells and compressor stations are not likely to be discernible beyond a distance of approximately 100 m in the downwind direction. However, source apportionment results indicate a significant contribution to regional VOCs from gas production sources, particularly for lower-molecular-weight alkanes (gas production. Implications: Rapid and extensive development of shale gas resources in recent years has created concerns about potential environmental impacts on water and air quality. This study focused on directly measuring the ambient air pollutant levels occurring at residential properties located near natural gas extraction and processing facilities, and estimating the relative contributions from gas production and motor vehicle emissions to ambient VOC concentrations. Although only a small-scale case study, the results may be useful for guidance in planning future ambient air quality studies and human exposure estimates in areas of intensive shale gas production.

  14. OPTIMIZATION OF MICROWAVE AND AIR DRYING CONDITIONS OF QUINCE (CYDONIA OBLONGA, MILLER USING RESPONSE SURFACE METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Cem Baltacioglu

    2015-03-01

    Full Text Available Effects of slice thickness of quince (Cydonia oblonga Miller , microwave incident power and air drying temperature on antioxidant activity and total phenolic content of quince were investigated during drying in microwave and air drying. Optimum conditions were found to be: i for microwave drying, 285 W and 4.14 mm thick (maximum antioxidant activity and 285 W and 6.85 mm thick (maximum total phenolic content, and ii for air drying, 75 ºC and 1.2 mm thick (both maximum antioxidant activity and total phenolic content. Drying conditions were optimized by using the response surface methodology. 13 experiments were carried out considering incident microwave powers from 285 to 795 W, air temperature from 46 to 74 ºC and slice thickness from 1.2 to 6.8 mm.

  15. Minor contributions of the maxillary sinus to the air-conditioning performance in macaque monkeys.

    Science.gov (United States)

    Mori, Futoshi; Hanida, Sho; Kumahata, Kiyoshi; Miyabe-Nishiwaki, Takako; Suzuki, Juri; Matsuzawa, Teruo; Nishimura, Takeshi D

    2015-08-01

    The nasal passages mainly adjust the temperature and humidity of inhaled air to reach the alveolar condition required in the lungs. By contrast to most other non-human primates, macaque monkeys are distributed widely among tropical, temperate and subarctic regions, and thus some species need to condition the inhaled air in cool and dry ambient atmospheric areas. The internal nasal anatomy is believed to have undergone adaptive modifications to improve the air-conditioning performance. Furthermore, the maxillary sinus (MS), an accessory hollow communicating with the nasal cavity, is found in macaques, whereas it is absent in most other extant Old World monkeys, including savanna monkeys. In this study, we used computational fluid dynamics simulations to simulate the airflow and heat and water exchange over the mucosal surface in the nasal passage. Using the topology models of the nasal cavity with and without the MS, we demonstrated that the MS makes little contribution to the airflow pattern and the air-conditioning performance within the nasal cavity in macaques. Instead, the inhaled air is conditioned well in the anterior portion of the nasal cavity before reaching the MS in both macaques and savanna monkeys. These findings suggest that the evolutionary modifications and coetaneous variations in the nasal anatomy are rather independent of transitions and variations in the climate and atmospheric environment found in the habitats of macaques. © 2015. Published by The Company of Biologists Ltd.

  16. Simulation and Optimization of a Solar Driven Air Conditioning System for Indian Cities

    OpenAIRE

    Sharma, Dev

    2013-01-01

    Simulation and Optimization of a Solar Driven Air Conditioning System for Indian Cities Conventional air-conditioners need high grade energy i.e. electricity, which in India, is primarily produced from fossil fuels. In spite of several emission restraints exercised by many countries under Kyoto protocol, energy consumption and pollution levels are higher than ever. Therefore, an assessment from the ecological point of view needs to be implemented as the greenhouse gases effect remains a threa...

  17. Air-conditioned university laboratories: Comparing CO2 measurement for centralized and split-unit systems

    Directory of Open Access Journals (Sweden)

    M. Hussin

    2017-04-01

    Full Text Available Universities are designed for higher education learning, and improving university indoor air quality (IAQ is essential to the enhanced performances of students and staff members alike. The majority of IAQ problems are due to inadequate ventilation in university buildings. Carbon Dioxide (CO2 measurements have become a commonly used screening test of IAQ because measurement levels can be used to evaluate the amount of ventilation and general comfort. This paper examines CO2 field measurement for undergraduate practical classes. Ten air conditioned laboratories with ventilation were chosen for CO2 field measurement. CO2 was monitored under indoor and outdoor conditions. Indoor CO2 concentration for Laboratories 1 and 10 is observed to be higher than 1000 ppm which indicated inadequate ventilation, while other laboratories showed CO2 concentrations less than 1000 ppm. Air capacity and outdoor air were calculated based on the design documentation. A comparison between design and actual outdoor air/person values indicates that the air conditioning systems of the laboratories had adequate ventilation.

  18. The covariance of air quality conditions in six cities in Southern Germany - The role of meteorology.

    Science.gov (United States)

    Dimitriou, Konstantinos; Kassomenos, Pavlos

    2017-01-01

    This paper analyzed air quality in six cities in Southern Germany (Ulm, Augsburg, Konstanz, Freiburg, Stuttgart and Munich), in conjunction with the prevailing synoptic conditions. Air quality was estimated through the calculation of a daily Air Stress Index (ASI) constituted by five independent components, each one expressing the contribution of one of the five main pollutants (PM10, O3, SO2, NO2 and CO) to the total air stress. As it was deduced from ASI components, PM10 from combustion sources and photochemically produced tropospheric O3 are the most hazardous pollutants at the studied sites, throughout cold and warm periods respectively, yet PM10 contribute substantially to the overall air stress during both seasons. The influence of anticyclonic high pressure systems, leading to atmospheric stagnation, was associated with increased ASI values, mainly due to the entrapment of PM10. Moderate air stress was generally estimated in all cities however a cleaner atmosphere was detected principally in Freiburg when North Europe was dominated by low pressure systems. Daily events of notably escalated ASI values were further analyzed with backward air mass trajectories. Throughout cold period, ASI episodes were commonly related to eastern airflows carrying exogenous PM10 originated from eastern continental Europe. During warm period, ASI episodes were connected to the arrival of regionally circulated air parcels reflecting lack of dispersion and accumulation of pollutants in accordance with the synoptic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Thermal sensation of Hong Kong people with increased air speed, temperature and humidity in air-conditioned environment

    Energy Technology Data Exchange (ETDEWEB)

    Chow, T.T. [School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Kowloon, Hong Kong SAR (China); Fong, K.F.; Lin, Zhang; Chan, A.L.S. [Division of Building Science and Technology, College of Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Kowloon, Hong Kong SAR (China); Givoni, B. [Department of Architecture, UCLA, Los Angeles, CA (United States); BGU, Beer Sheva (Israel)

    2010-10-15

    In the warm and humid climate zone, air-conditioning (AC) is usually provided at working places to enhance human thermal comfort and work productivity. From the building sustainability point of view, to achieve acceptable thermal sensation with the minimum use of energy can be desirable. A new AC design tactic is then to increase the air movement so that the summer temperature setting can be raised. A laboratory-based thermal comfort survey was conducted in Hong Kong with around 300 educated Chinese subjects. Their thermal sensation votes were gathered for a range of controlled thermal environment. The result analysis shows that, like in many other Asian cities, the thermal sensation of the Hong Kong people is sensitive to air temperature and speed, but not much to humidity. With bodily air speed at 0.1-0.2 m/s, clothing level 0.55 clo and metabolic rate 1 met, the neutral temperature was found around 25.4 C for sedentary working environment. Then recommendations are given to the appropriate controlled AC environment in Hong Kong with higher airflow speeds. (author)

  20. Source Term Estimates of Radioxenon Released from the BaTek Medical Isotope Production Facility Using External Measured Air Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Eslinger, Paul W.; Cameron, Ian M.; Dumais, Johannes R.; Imardjoko, Yudi; Marsoem, Pujadi; McIntyre, Justin I.; Miley, Harry S.; Stoehlker, Ulrich; Widodo, Susilo; Woods, Vincent T.

    2015-10-01

    Abstract Batan Teknologi (BaTek) operates an isotope production facility in Serpong, Indonesia that supplies 99mTc for use in medical procedures. Atmospheric releases of Xe-133 in the production process at BaTek are known to influence the measurements taken at the closest stations of the International Monitoring System (IMS). The purpose of the IMS is to detect evidence of nuclear explosions, including atmospheric releases of radionuclides. The xenon isotopes released from BaTek are the same as those produced in a nuclear explosion, but the isotopic ratios are different. Knowledge of the magnitude of releases from the isotope production facility helps inform analysts trying to decide whether a specific measurement result came from a nuclear explosion. A stack monitor deployed at BaTek in 2013 measured releases to the atmosphere for several isotopes. The facility operates on a weekly cycle, and the stack data for June 15-21, 2013 show a release of 1.84E13 Bq of Xe-133. Concentrations of Xe-133 in the air are available at the same time from a xenon sampler located 14 km from BaTek. An optimization process using atmospheric transport modeling and the sampler air concentrations produced a release estimate of 1.88E13 Bq. The same optimization process yielded a release estimate of 1.70E13 Bq for a different week in 2012. The stack release value and the two optimized estimates are all within 10 percent of each other. Weekly release estimates of 1.8E13 Bq and a 40 percent facility operation rate yields a rough annual release estimate of 3.7E13 Bq of Xe-133. This value is consistent with previously published estimates of annual releases for this facility, which are based on measurements at three IMS stations. These multiple lines of evidence cross-validate the stack release estimates and the release estimates from atmospheric samplers.

  1. Hazardous Waste Treatment, Storage, and Disposal Facilities-Organic Air Emission Standards for Process Vents and Equipment Leaks - Technical Amendment - Federal Register Notice, April 26, 1991

    Science.gov (United States)

    This document corrects typographical errors in the regulatory text of the final standards that would limit organic air emissions as a class at hazardous waste treatment, storage, and disposal facilities (TSDF) that are subject to regulation under subtitle

  2. Feasibility Assessment of an ISS Artificial Gravity Conditioning Facility by Means of Multi-Body Approach

    Science.gov (United States)

    Toso, Mario; Baldesi, Gianluigi; Moratto, Claudio; De Wilde, Don; Bureo Dacal, Rafael; Castellsaguer, Joaquim

    2012-07-01

    Even though human exploration of Mars is a distant objective, it is well understood that, for human space voyages of several years duration, crews would be at risk of catastrophic consequences should any of the systems that provide adequate air, water, food, or thermal protection fail. Moreover, crews will face serious health and/or safety risks resulting from severe physiologic deconditioning associated with prolonged weightlessness. The principal ones are related to physical and functional deterioration of the regulation of the blood circulation, decreased aerobic capacity, impaired musculo-skeletal systems, and altered sensory- motor system performance. As the reliance of future space programmes on virtual modelling, simulation and justification has substantially grown together with the proto-flight hardware development approach, a range of simulation capabilities have become increasingly important in the requirements specification, design, verification, testing, launch and operation of new space systems. In this frame, multibody software is a key tool in providing a more coordinated and consistent approach from the preliminary development phases of the most complex systems. From a scientific prospective, an artificial gravity facility, such as the one evaluated in this paper, would be the first in-flight testing of the effectiveness and acceptability of short radius centrifuge as a countermeasure to human deconditioning on orbit. The ISS represents a unique opportunity to perform this research. From an engineering point of view, the preliminary assessment described in this paper, highlights the difficult engineering challenges of such a facility. The outcome proves that a human can be accommodated in the available volume, while respecting the human ergonomic basic requirements and preserving the global structural integrity of the hosting ISS module. In particular, analysis shows that, although the load capacity of the structural interfaces imposes a very low

  3. Facile SILAR approach to air-stable naked silver and gold nanoparticles supported by alumina.

    Science.gov (United States)

    Stamplecoskie, Kevin G; Manser, Joseph S

    2014-10-22

    A synthetically convenient and scalable SILAR (successive ion layer adsorption and reaction) method is used to make air-stable films of silver and gold nanoparticles supported on alumina scaffolds. This solution-based deposition technique yields particles devoid of insulating capping agents or ligands. The optical properties of the nanoparticle films were investigated using femtosecond transient absorption spectroscopy. A linear absorption arising from intraband excitation (775 nm laser pulse) is seen only for Au nanoparticles at low intensity. However, both Au and Ag particles exhibit plasmon resonance responses at high excitation intensity via two photon absorption of the 775 nm pump pulse. The difference in optical response to near-IR laser excitation is rationalized based on the known density of states for each metal. To demonstrate the potential applications of these films, alumina-supported Ag nanoparticles were utilized as substrates for surface enhanced Raman spectroscopy, resulting in a 65-fold enhancement in the Raman signal of the probe molecule rhodamine 6G. The exceptional stability and scalability of these SILAR films opens the door for further optical and photocatalytic studies and applications, particularly with ligand-free Ag nanoparticles that typically oxidize under ambient conditions. Additionally, isolating plasmonic and interband electronic excitations in stable AgNP under visible light irradiation could enable elucidation of the mechanisms that drive noble metal-assisted photocatalytic processes.

  4. Air Force Research Laboratory Spacecraft Cryocooler Endurance Evaluation Facility Closing Report

    Science.gov (United States)

    Armstrong, J.; Martin, K. W.; Fraser, T.

    2015-12-01

    The Air Force Research Laboratory (AFRL) Spacecraft Component Thermal Research Group has been devoted to evaluating lifetime performance of space cryocooler technology for over twenty years. Long-life data is essential for confirming design lifetimes for space cryocoolers. Continuous operation in a simulated space environment is the only accepted method to test for degradation. AFRL has provided raw data and detailed evaluations to cryocooler developers for advancing the technology, correcting discovered deficiencies, and improving cryocooler designs. At AFRL, units of varying design and refrigeration cycles were instrumented in state-of-the-art experiment stands to provide spacelike conditions and were equipped with software data acquisition to track critical cryocooler operating parameters. This data allowed an assessment of the technology's ability to meet the desired lifetime and documented any long-term changes in performance. This paper will outline a final report of the various flight cryocoolers tested in our laboratory. The data summarized includes the seven cryocoolers tested during 2014-2015. These seven coolers have a combined total of 433,326 hours (49.5 years) of operation.

  5. Solar air conditioning: introduction and basics; Solare Klimatisierung Einfuehrung und Grundlagen

    Energy Technology Data Exchange (ETDEWEB)

    Albers, J. [Inst. fuer Erhaltung und Modernisierung von Bauwerken e.V. an der Technische Univ. Berlin (Germany)

    2005-07-01

    A considerable increase of the cold energy demand is expected world-wide in the coming years. Electrically operated cold compression plants are currently used at the most in order to meet the cold energy demand resulting also in a rising electric current and primary energy demand. This can have an effect on the supply security as well as on the change of the world climate. Therefore more alternative methods of cold generation are supposed to be applied in the future. The following contribution describes that plant systems for solar air conditioning (SAC-systems) are an attractive and feasible technology that demands engineering but can also be further developed and can make an important contribution to the target mentioned above. First an overview is provided of conventional air conditioning technology and of the expected development tendencies with regard to cold demand. Afterwards the currently available solar air conditioning methods and their possible applications are explained. (orig.)

  6. Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-07-01

    Full Text Available The article presents numerical analysis of exergy for air-conditioning influenced by ambient temperature. The model of numerical simulation uses an integrated air conditioning system exposed in varied ambient temperature to observe change of the four main devices, the compressor, the condenser, the capillary, and the evaporator in correspondence to ambient temperature. The analysis devices of the four devices’s exergy influenced by the varied ambient temperature and found that the capillary has unusual increasing exergy loss vs. increasing ambient temperature in comparison to the other devices. The result shows that reducing exergy loss of the capillary influenced by the ambient temperature is the key for improving working efficiency of an air-conditioning system when influence of the ambient temperature is considered. The higher ambient temperature causes the larger pressure drop of capillary and more exergy loss.

  7. An Expert Fault Diagnosis System for Vehicle Air Conditioning Product Development

    Science.gov (United States)

    Tan, C. F.; Tee, B. T.; Khalil, S. N.; Chen, W.; Rauterberg, G. W. M.

    2015-09-01

    The paper describes the development of the vehicle air-conditioning fault diagnosis system in automotive industries with expert system shell. The main aim of the research is to diagnose the problem of new vehicle air-conditioning system development process and select the most suitable solution to the problems. In the vehicle air-conditioning manufacturing industry, process can be very costly where an expert and experience personnel needed in certain circumstances. The expert of in the industry will retire or resign from time to time. When the expert is absent, their experience and knowledge is difficult to retrieve or lost forever. Expert system is a convenient method to replace expert. By replacing the expert with expert system, the accuracy of the processes will be increased compared to the conventional way. Therefore, the quality of product services that are produced will be finer and better. The inputs for the fault diagnosis are based on design data and experience of the engineer.

  8. Impact of the electric compressor for automotive air conditioning system on fuel consumption and performance analysis

    Science.gov (United States)

    Zulkifli, A. A.; Dahlan, A. A.; Zulkifli, A. H.; Nasution, H.; Aziz, A. A.; Perang, M. R. M.; Jamil, H. M.; Misseri, M. N.

    2015-12-01

    Air conditioning system is the biggest auxiliary load in a vehicle where the compressor consumed the largest. Problem with conventional compressor is the cooling capacity cannot be control directly to fulfill the demand of thermal load inside vehicle cabin. This study is conducted experimentally to analyze the difference of fuel usage and air conditioning performance between conventional compressor and electric compressor of the air conditioning system in automobile. The electric compressor is powered by the car battery in non-electric vehicle which the alternator will recharge the battery. The car is setup on a roller dynamometer and the vehicle speed is varied at 0, 30, 60, 90 and 110 km/h at cabin temperature of 25°C and internal heat load of 100 and 400 Watt. The results shows electric compressor has better fuel consumption and coefficient of performance compared to the conventional compressor.

  9. Extension of the PMV model to non-air-conditioned building in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  10. Prediction of thermal sensation in non-air-conditioned buildings in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  11. Exergy analysis of heating, refrigerating and air conditioning methods and applications

    CERN Document Server

    Dincer, Ibrahim

    2015-01-01

    Improve and optimize efficiency of HVAC and related energy systems from an exergy perspective. From fundamentals to advanced applications, Exergy Analysis of Heating, Air Conditioning, and Refrigeration provides readers with a clear and concise description of exergy analysis and its many uses. Focusing on the application of exergy methods to the primary technologies for heating, refrigerating, and air conditioning, Ibrahim Dincer and Marc A. Rosen demonstrate exactly how exergy can help improve and optimize efficiency, environmental performance, and cost-effectiveness. The book also discusses the analysis tools available, and includes many comprehensive case studies on current and emerging systems and technologies for real-world examples. From introducing exergy and thermodynamic fundamentals to presenting the use of exergy methods for heating, refrigeration, and air conditioning systems, this book equips any researcher or practicing engineer with the tools needed to learn and master the application of exergy...

  12. SUMMARY OF ELECTRIC SERVICE COSTS FOR TOTALLY AIR CONDITIONED SCHOOLS PREPARED FOR HOUSTON INDEPENDENT SCHOOL DISTRICT, MAY 31, 1967.

    Science.gov (United States)

    WHITESIDES, M.M.

    THIS REPORT IS A COMPILATION OF DATA ON ELECTRIC AIR CONDITIONING COSTS, OPERATIONS AND MAINTENANCE. AIR CONDITIONING UNITS ARE COMPARED IN TERMS OF ELECTRIC VERSUS NON-ELECTRIC, AUTOMATIC VERSUS OPERATED, AIR COOLED VERSUS WATER COOLED, RECIPROCATING VERSUS CENTRIFUGAL COMPRESSORS, SPACE AND NOISE, REHEAT, MAINTENANCE AND ORIGINAL COST. DATA ARE…

  13. Parametric analysis of a combined dew point evaporative-vapour compression based air conditioning system

    Directory of Open Access Journals (Sweden)

    Shailendra Singh Chauhan

    2016-09-01

    Full Text Available A dew point evaporative-vapour compression based combined air conditioning system for providing good human comfort conditions at a low cost has been proposed in this paper. The proposed system has been parametrically analysed for a wide range of ambient temperatures and specific humidity under some reasonable assumptions. The proposed system has also been compared from the conventional vapour compression air conditioner on the basis of cooling load on the cooling coil working on 100% fresh air assumption. The saving of cooling load on the coil was found to be maximum with a value of 60.93% at 46 °C and 6 g/kg specific humidity, while it was negative for very high humidity of ambient air, which indicates that proposed system is applicable for dry and moderate humid conditions but not for very humid conditions. The system is working well with an average net monthly power saving of 192.31 kW h for hot and dry conditions and 124.38 kW h for hot and moderate humid conditions. Therefore it could be a better alternative for dry and moderate humid climate with a payback period of 7.2 years.

  14. Early influence of bilateral turbinoplasty combined with septoplasty on intranasal air conditioning.

    Science.gov (United States)

    Lindemann, Joerg; Keck, Tilman; Leiacker, Richard; Dzida, Rene; Wiesmiller, Kerstin

    2008-01-01

    Too extensive resection of the inferior turbinates (ITs) during nasal surgery leads to a severely disturbed intranasal air conditioning. Data comparing nasal air conditioning before and after turbinoplasty in nasal surgery are still lacking. The aim of this study was to determine the early effect of bilateral turbinoplasty combined with septoplasty on intranasal heating and humidification. Twelve patients were included into this prospective study. In one-half of the patients a bilateral turbinoplasty of the IT during nasal surgery was performed, in the other half no surgery on the IT was performed. Intranasal air temperature and humidity were measured before and after surgery. A combined miniaturized thermocouple and a humidity sensor were used for simultaneous in vivo intranasal measurements. There were no statistically significant differences in temperature and humidity values between the two study groups before surgery (p > 0.05). In both groups, the postoperative temperature and humidity values were statistically significantly higher compared with the preoperative ones (p air conditioning was improved after surgery. A carefully performed and conservative reduction of the IT in nasal surgery seems to even improve intranasal air conditioning.

  15. Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System

    Science.gov (United States)

    Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao

    The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.

  16. Nonradioactive air emissions notice of construction for the Waste Receiving And Processing facility

    Energy Technology Data Exchange (ETDEWEB)

    1993-02-01

    The mission of the Waste Receiving And Processing (WRAP) Module 1 facility (also referred to as WRAP 1) is to examine assay, characterize, treat, and repackage solid radioactive and mixed waste to enable permanent disposal of the wastes in accordance with all applicable regulations. WRAP 1 will contain equipment and facilities necessary for non-destructive examination (NDE) of wastes and to perform a non-destructive examination assay (NDA) of the total radionuclide content of the wastes, without opening the outer container (e.g., 55-gal drum). WRAP 1 will also be equipped to open drums which do not meet waste acceptance and shipping criteria, and to perform limited physical treatment of the wastes to ensure that storage, shipping, and disposal criteria are met. The solid wastes to be handled in the WRAP 1 facility include low level waste (LLW), transuranic (TRU) waste, and transuranic and low level mixed wastes (LLMW). The WRAP 1 facility will only accept contact handler (CH) waste containers. A Best Available Control Technology for Toxics (TBACT) assessment has been completed for the WRAP 1 facility (WHC 1993). Because toxic emissions from the WRAP 1 facility are sufficiently low and do not pose any health or safety concerns to the public, no controls for volatile organic compounds (VOCs), and installation of HEPA filters for particulates satisfy TBACT for the facility.

  17. Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.

    Science.gov (United States)

    Gniadek, Agnieszka; Macura, Anna B

    2011-01-01

    Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.

  18. Modeling and HIL Simulation of Flight Conditions Simulating Control System for the Altitude Test Facility

    Science.gov (United States)

    Zhou, Jun; Shen, Li; Zhang, Tianhong

    2016-12-01

    Simulated altitude test is an essential exploring, debugging, verification and validation means during the development of aero-engine. Free-jet engine test can simulate actual working conditions of aero-engine more realistically than direct-connect engine test but with relatively lower cost compared to propulsion wind tunnel test, thus becoming an important developing area of simulated altitude test technology. The Flight Conditions Simulating Control System (FCSCS) is of great importance to the Altitude Test Facility (ATF) but the development of that is a huge challenge. Aiming at improving the design efficiency and reducing risks during the development of FCSCS for ATFs, a Hardware- in-the-Loop (HIL) simulation system was designed and the mathematical models of key components such as the pressure stabilizing chamber, free-jet nozzle, control valve and aero-engine were built in this paper. Moreover, some HIL simulation experiments were carried out. The results show that the HIL simulation system designed and established in this paper is reasonable and effective, which can be used to adjust control parameters conveniently and assess the software and hardware in the control system immediately.

  19. Test facility and the available inlet flow condition to transonic radial diffusers

    Energy Technology Data Exchange (ETDEWEB)

    Hayami, Hiroshi; Senoo, Yasutoshi; Nakashima, Koji; Kawaguchi, Nobumasa

    1987-12-28

    In order to stabilize the characteristics combined with diffuser(DF) and expand the flow rate range, a transonic centrifugal impeller(B rotor) with backward blade angle of 40deg was made trially. Single characteristic was tested for five rotating speed equal to or less than 19,000 rpm with freon R12. The flow rate range from choke to inducer(ID) stalling for B rotor is 17% of choke flow rate which is comaratively wider than 11% of conventional impeller(R rotor) with forward blade angle. When the flow field of impeller exit, that is, DF inlet is considered, the maximum value of inlet flow angle in a constant rotating speed corresponds to choke condition or maximum flow rate and minimum value corresponds to operating condition of critical flow rate resulting ID spalling speed. Inflow Mach number to DF changes mainly for the impeller rotating speed. It is possible to pursue the experimental work on diffusers in the range of 21deg(max) to 11.6deg(min) inflow angle and up to 1.31 Mach number using the present facility. (9 figs, 4 refs)

  20. Research on Using the Naturally Cold Air and the Snow for Data Center Air-conditioning, and Humidity Control

    Science.gov (United States)

    Tsuda, Kunikazu; Tano, Shunichi; Ichino, Junko

    To lower power consumption has becomes a worldwide concern. It is also becoming a bigger area in Computer Systems, such as reflected by the growing use of software-as-a-service and cloud computing whose market has increased since 2000, at the same time, the number of data centers that accumulates and manages the computer has increased rapidly. Power consumption at data centers is accounts for a big share of the entire IT power usage, and is still rapidly increasing. This research focuses on the air-conditioning that occupies accounts for the biggest portion of electric power consumption by data centers, and proposes to develop a technique to lower the power consumption by applying the natural cool air and the snow for control temperature and humidity. We verify those effectiveness of this approach by the experiment. Furthermore, we also examine the extent to which energy reduction is possible when a data center is located in Hokkaido.

  1. Facile one-step fabrication of magnetite particles under mild hydrothermal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Keerthana, D. Shanthini; Namratha, K. [Centre for Materials Science and Technology, Vijnana Bhavan, University of Mysore, Manasagangothri, Mysore 6 (India); Byrappa, K., E-mail: kbyrappa@gmail.com [Centre for Materials Science and Technology, Vijnana Bhavan, University of Mysore, Manasagangothri, Mysore 6 (India); Yathirajan, H.S. [Centre for Materials Science and Technology, Vijnana Bhavan, University of Mysore, Manasagangothri, Mysore 6 (India); DOS in Chemistry, University of Mysore, Manasagangothri, Mysore 6 (India)

    2015-03-15

    Hydrophilic magnetite particles for biological applications were synthesized by hydrothermal method in the presence of D-Glucose as both reducing and capping agent in a facile, one-step, low energy and environmentally friendly route. The role of D-Glucose as a reducing agent in the formation of magnetite particles under mild hydrothermal conditions has been investigated. The absence of D-Glucose results in the formation of hematite. The magnetite particles synthesized were characterized using powder X-ray Diffraction (XRD), Fourier Transform Infrared (FTIR) Spectroscopy, High Resolution Scanning Electron Microscopy (HR-SEM), Dynamic Light Scattering (DLS) and Vibrating Sample Magnetometery (VSM). The influence of the quantity of D-Glucose used and the reaction duration on the formation of magnetite were studied. DLS and HR-SEM results show that the size of the particles was in nano- to micron range. The antioxidant potency of the particles was confirmed using DPPH assay, where 2,2- Diphenyl-1-picrylhydrazyl was used as a source of free radicals. Hence the magnetite particles obtained could be considered for the use in various biological applications. - Highlights: • Magnetite and hematite particles were synthesized using hydrothermal route. • The reactants and experimental parameters were optimized to get single phase magnetite particles. • The role of D-Glucose as a reducing and capping agent is discussed. • The magnetite particles showed very good free radical scavenging ability. • The authors report a simple, facile, one-step method using hydrated ferric salt as a single iron precursor.

  2. Radio-Ecological Conditions of Groundwater in the Area of Uranium Mining and Milling Facility - 13525

    Energy Technology Data Exchange (ETDEWEB)

    Titov, A.V.; Semenova, M.P.; Seregin, V.A.; Isaev, D.V.; Metlyaev, E.G. [FSBU SRC A.I.Burnasyan Federal Medical Biophysical Center of FMBA of Russia, Zhivopisnaya Street, 46, Moscow (Russian Federation); Glagolev, A.V.; Klimova, T.I.; Sevtinova, E.B. [FSESP ' Hydrospecgeologiya' (Russian Federation); Zolotukhina, S.B.; Zhuravleva, L.A. [FSHE ' Centre of Hygiene and Epidemiology no. 107' under FMBA of Russia (Russian Federation)

    2013-07-01

    Manmade chemical and radioactive contamination of groundwater is one of damaging effects of the uranium mining and milling facilities. Groundwater contamination is of special importance for the area of Priargun Production Mining and Chemical Association, JSC 'PPMCA', because groundwater is the only source of drinking water. The paper describes natural conditions of the site, provides information on changes of near-surface area since the beginning of the company, illustrates the main trends of contaminators migration and assesses manmade impact on the quality and mode of near-surface and ground waters. The paper also provides the results of chemical and radioactive measurements in groundwater at various distances from the sources of manmade contamination to the drinking water supply areas. We show that development of deposits, mine water discharge, leakages from tailing dams and cinder storage facility changed general hydro-chemical balance of the area, contributed to new (overlaid) aureoles and flows of scattering paragenetic uranium elements, which are much smaller in comparison with natural ones. However, increasing flow of groundwater stream at the mouth of Sukhoi Urulyungui due to technological water infiltration, mixing of natural water with filtration streams from industrial reservoirs and sites, containing elevated (relative to natural background) levels of sulfate-, hydro-carbonate and carbonate- ions, led to the development and moving of the uranium contamination aureole from the undeveloped field 'Polevoye' to the water inlet area. The aureole front crossed the southern border of water inlet of drinking purpose. The qualitative composition of groundwater, especially in the southern part of water inlet, steadily changes for the worse. The current Russian intervention levels of gross alpha activity and of some natural radionuclides including {sup 222}Rn are in excess in drinking water; regulations for fluorine and manganese

  3. CFD Analysis of Manipulator Cabin by Selecting Proper Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Umesh S. Ghorpade

    2017-01-01

    Full Text Available Manipulator is a machine which is used to transfer heavy objects, to reduce human efforts in many industrial applications. Some of them are fully automated while some are manually operated. It is difficult to work in cabin of manipulator for the operator under hot conditions. So it is essential to provide comfort to operator using air-conditioning system. For such applications standard air conditioners are not compatible, so we have to develop assembled system. In this paper we will be dealing with design, selection and fabrication of components like compressor, condenser, expansion device and evaporator. In order to do so, we have calculated heat load.

  4. Influence of the turbinate volumes as measured by magnetic resonance imaging on nasal air conditioning.

    Science.gov (United States)

    Lindemann, Joerg; Tsakiropoulou, Evangelia; Vital, Victor; Keck, Tilman; Leiacker, Richard; Pauls, Sandra; Wacke, Florian; Wiesmiller, Kerstin M

    2009-01-01

    Changes in nasal airflow caused by varying intranasal volumes and cross-sectional areas affect the contact between air and surrounding mucosa entailing alterations in nasal air conditioning. This study evaluates the correlation between nasal air conditioning and the volumes of the inferior and middle turbinates as measured by magnetic resonance imaging (MRI). Fourteen healthy volunteers were enrolled. Each volunteer had been examined by rhinomanometry, acoustic rhinometry, intranasal air temperature, and humidity measurements at defined intranasal sites as well as MRI of the nasal cavity and the paranasal sinuses. The volumetric data of the turbinates was based on the volumetric software Amira. Comparable results were obtained regarding absolute humidity values and temperature values within the nasal valve area and middle turbinate area for both the right and the left side of the nasal cavity. No statistically significant differences were found in the rhinomanometric values and the acoustic rhinometry results of both sides (p > 0.05). No statistical correlations were found between the volumes of the inferior (mean, 6.1 cm3) and middle turbinate (mean, 1.8 cm3) and the corresponding humidity and temperature values. Additionally, the air temperature and humidity values did not correlate with the rhinometrical endonasal volumes (0-20 mm and 20-50 mm from the nasal entrance). The normal range of volumes of the inferior and middle turbinate does not seem to have a significant impact on intranasal air conditioning in healthy subjects. The exact limits where alterations of the turbinate volume negatively affect nasal air conditioning are still unknown.

  5. Conditioning the middle ear reflex at sensation levels below reflex threshold: air jet and electrical stimulation.

    Science.gov (United States)

    McDaniel-Bacon, L; Fulton, R T; Laskowski, R P

    1980-01-01

    An ABAB functional analysis, conditioning and generalization, design was used in 3 experiments (2 were formal studies and 1 was empirical in nature) to investigate the conditionability of the middle ear reflex. The conditioned stimuli were subreflex threshold pure tones of various frequencies and intensities. The unconditioned stimulus (UCS) was an auricular air jet to the contralateral ear in the first experiment and cutaneous electrical stimulation to the ipsolateral, probe ear in the last 2 experiments. Reflexes were monitored by an otoadmittance meter, storage oscilloscope, and strip chart recorder. In the first experiment (air jet UCS), no subjects met the conditioning criterion within the maximum presentation of 400 paired trials, despite pilot evidence which indicated conditioning was feasible. In the second experiment (electrical stimulation UCS), 2 subjects met conditioning criterion; however, only one subject reconditioned and demonstrated partial generalization to other conditioned stimuli. In the third experiment (electrical stimulation UCS), one of 3 subjects who had previously been unconditionable with the air jet UCS met conditioning and reconditioning criterion and demonstrated partial generalization. Results indicate that the middle ear reflex can be conditioned to be elicited by subreflex threshold pure tones, however, results are limited.

  6. Keeping cool: use of air conditioning by australians with multiple sclerosis.

    Science.gov (United States)

    Summers, Michael P; Simmons, Rex D; Verikios, George

    2012-01-01

    Despite the known difficulties many people with MS have with high ambient temperatures, there are no reported studies of air conditioning use and MS. This study systematically examined air conditioner use by Australians with MS. A short survey was sent to all participants in the Australian MS Longitudinal Study cohort with a response rate of 76% (n = 2,385). Questions included hours of air-conditioner use, areas cooled, type and age of equipment, and the personal effects of overheating. Air conditioners were used by 81.9% of respondents, with an additional 9.6% who could not afford an air conditioner. Regional and seasonal variation in air conditioning use was reported, with a national annual mean of 1,557 hours running time. 90.7% reported negative effects from overheating including increased fatigue, an increase in other MS symptoms, reduced household and social activities, and reduced work capacity. Households that include people with MS spend between 4 and 12 times more on keeping cool than average Australian households.

  7. Preliminary verification of instantaneous air temperature estimation for clear sky conditions based on SEBAL

    Science.gov (United States)

    Zhu, Shanyou; Zhou, Chuxuan; Zhang, Guixin; Zhang, Hailong; Hua, Junwei

    2017-02-01

    Spatially distributed near surface air temperature at the height of 2 m is an important input parameter for the land surface models. It is of great significance in both theoretical research and practical applications to retrieve instantaneous air temperature data from remote sensing observations. An approach based on Surface Energy Balance Algorithm for Land (SEBAL) to retrieve air temperature under clear sky conditions is presented. Taking the meteorological measurement data at one station as the reference and remotely sensed data as the model input, the research estimates the air temperature by using an iterative computation. The method was applied to the area of Jiangsu province for nine scenes by using MODIS data products, as well as part of Fujian province, China based on four scenes of Landsat 8 imagery. Comparing the air temperature estimated from the proposed method with that of the meteorological station measurement, results show that the root mean square error is 1.7 and 2.6 °C at 1000 and 30 m spatial resolution respectively. Sensitivity analysis of influencing factors reveals that land surface temperature is the most sensitive to the estimation precision. Research results indicate that the method has great potentiality to be used to estimate instantaneous air temperature distribution under clear sky conditions.

  8. Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations) Air Toxics Rule Fact Sheets

    Science.gov (United States)

    This page contains a November 1994 fact sheet for the final NESHAP for Gasoline Distribution Facilities. This page also contains a December fact sheet with information regarding the final amendments to the 2003 final rule for the NESHAP.

  9. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    OpenAIRE

    Sanda Budea

    2014-01-01

    Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outle...

  10. Droplets spectrum of air-assisted boom sprayers under different environmental and operational conditions

    Directory of Open Access Journals (Sweden)

    Robson S. Sasaki

    2016-01-01

    Full Text Available ABSTRACT During pesticide spraying, the psychrometric conditions of the air may cause evaporation of the droplets along their trajectory from the nozzle to the target. Thus, this study aimed to evaluate the effect of air psychrometric conditions and operating pressure on the droplet spectrum of air-assisted boom sprayers. The test was performed using a prototype equipped with an axial fan, a flow homogenizer, temperature and relative air humidity sensors, a spray nozzle and a gas-heating system to warm up the airflow. With the assembled system and the aid of a particle analyser, the JSF 11002 spray nozzle was evaluated with respect to droplet spectrum in four air psychrometric conditions (7, 14, 21 and 28 hPa and at four operating pressures (200, 300, 400 and 500 kPa. At the end, evaporation losses were observed during the sprayings. For a given operating pressure and for each increment of 1 hPa in vapor pressure deficit, there was a diameter reduction of approximately 0.0759, 0.518 and 1.514 μm for the parameters DV0.1, DV0.5 and DV0.9, respectively. The diameter of the droplets decreased as the operating pressure increased.

  11. Energy and Greenhouse Gas Emission Assessment of Conventional and Solar Assisted Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    Xiaofeng Li

    2015-11-01

    Full Text Available Energy consumption in the buildings is responsible for 26% of Australia’s greenhouse gas emissions where cooling typically accounts for over 50% of the total building energy use. The aim of this study was to investigate the potential for reducing the cooling systems’ environmental footprint with applications of alternative renewable energy source. Three types of cooling systems, water cooled, air cooled and a hybrid solar-based air-conditioning system, with a total of six scenarios were designed in this work. The scenarios accounted for the types of power supply to the air-conditioning systems with electricity from the grid and with a solar power from highly integrated building photovoltaics (BIPV. Within and between these scenarios, systems’ energy performances were compared based on energy modelling while the harvesting potential of the renewable energy source was further predicted based on building’s detailed geometrical model. The results showed that renewable energy obtained via BIPV scenario could cover building’s annual electricity consumption for cooling and reduce 140 tonnes of greenhouse gas emissions each year. The hybrid solar air-conditioning system has higher energy efficiency than the air cooled chiller system but lower than the water cooled system.

  12. Ecological succession of the microbial communities of an air-conditioning cooling coil in the tropics.

    Science.gov (United States)

    Acerbi, E; Chénard, C; Miller, D; Gaultier, N E; Heinle, C E; Chang, V W-C; Uchida, A; Drautz-Moses, D I; Schuster, S C; Lauro, F M

    2017-03-01

    Air-conditioning systems harbor microorganisms, potentially spreading them to indoor environments. While air and surfaces in air-conditioning systems are periodically sampled as potential sources of indoor microbes, little is known about the dynamics of cooling coil-associated communities and their effect on the downstream airflow. Here, we conducted a 4-week time series sampling to characterize the succession of an air-conditioning duct and cooling coil after cleaning. Using an universal primer pair targeting hypervariable regions of the 16S/18S ribosomal RNA, we observed a community succession for the condensed water, with the most abundant airborne taxon Agaricomycetes fungi dominating the initial phase and Sphingomonas bacteria becoming the most prevalent taxa toward the end of the experiment. Duplicate air samples collected upstream and downstream of the coil suggest that the system does not act as ecological filter or source/sink for specific microbial taxa during the duration of the experiment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Detonation cell size measurements in high-temperature hydrogen-air-steam mixtures at the BNL high-temperature combustion facility

    Energy Technology Data Exchange (ETDEWEB)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.L. [and others

    1997-11-01

    The High-Temperature Combustion Facility (HTCF) was designed and constructed with the objective of studying detonation phenomena in mixtures of hydrogen-air-steam at initially high temperatures. The central element of the HTCF is a 27-cm inner-diameter, 21.3-m long cylindrical test vessel capable of being heating to 700K {+-} 14K. A unique feature of the HTCF is the {open_quotes}diaphragmless{close_quotes} acetylene-oxygen gas driver which is used to initiate the detonation in the test gas. Cell size measurements have shown that for any hydrogen-air-steam mixture, increasing the initial mixture temperature, in the range of 300K to 650K, while maintaining the initial pressure of 0.1 MPa, decreases the cell size and thus makes the mixture more detonable. The effect of steam dilution on cell size was tested in stoichiometric and off-stoichiometric (e.g., equivalence ratio of 0.5) hydrogen-air mixtures. Increasing the steam dilution in hydrogen-air mixtures at 0.1 MPa initial pressure increases the cell size, irrespective of initial temperature. It is also observed that the desensitizing effect of steam diminished with increased initial temperature. A 1-dimensional, steady-state Zel`dovich, von Neumann, Doring (ZND) model, with full chemical kinetics, has been used to predict cell size for hydrogen-air-steam mixtures at different initial conditions. Qualitatively the model predicts the overall trends observed in the measured cell size versus mixture composition and initial temperature and pressure. It was found that the proportionality constant used to predict detonation cell size from the calculated ZND model reaction zone varies between 10 and 100 depending on the mixture composition and initial temperature. 32 refs., 35 figs.

  14. Characteristics of drift-flux models for the 3' diameter vertical-upward air-water flow condition

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, V. T.; Euh, D. J.; Song, C. H. [KAERI, Daejeon (Korea, Republic of)

    2009-07-01

    One of the more complex aspects of two-phase flow calculations is the determination of the void fraction. An accurate estimation of this parameter is important for understanding and predicting the behavior of systems during a wide variety of transient conditions. The drift-flux models are based on correlations to compute the void fraction distribution and slip in a two-phase flow needed to obtain the relative velocity between the phases. Thus, the accuracy of the correlation has a decisive role in determining the correct transport of the two-phases in the system. In this paper, the assessment of 7 correlations based on the Zuber-Findlay model has been done by using the experimental data which were performed on the 3' diameter vertical-upward air-water test facility in KAERI. The void fraction was measured by using the impedance void meter which has a good dynamic resolution to get the values directly without any further data treatment. A total of 28 flow conditions have been performed at 2 bar and 3 bar inlet pressure conditions with temperature of 30 .deg. C, superficial liquid and gas velocity range of 0.5-2.8 m/s and 0.044-1.025 m/s. Some physical phenomena relevant to inlet flow condition and pressure effect were investigated. The results of assessment show a good predictive capability of Bestion model, which is currently used in the system code CATHARE.

  15. BIFoR FACE: A Free-Air Carbon Dioxide Enrichment (FACE) facility in old-growth temperate deciduous woodland

    Science.gov (United States)

    MacKenzie, Rob; Thomas, Rick; Ellsworth, David; Hemming, Debbie; Crous, Kristine; Blaen, Phillip; Poynter, Alex; Blenkhorn, Daniel; Pope, Francis

    2016-04-01

    The Birmingham Institute of Forest research (BIFoR) focuses on fundamental physical, biological, ecological, social and cultural research of direct relevance to forested landscapes worldwide. A core platform for BIFoR is a Free-Air Carbon Dioxide Enrichment (FACE) facility, with which we study the ten-year response of a mature temperate deciduous forest ecosystem to a 150-ppmv step-change in atmospheric [CO2]. BIFoR FACE is being established in Mill Haft, a mature (~150 year-old) oak (Quercus robur) and hazel (Corylus avellana) coppice-with-standards woodland in central England, UK. The facility enables elevated CO2 (eCO2) treatments to be introduced in 30 m diameter rings (3 treatment plots, 3 fully-replicated control plots, and 3 unmodified ambient controls). Primary research questions focus on carbon uptake and storage, corresponding nutrient limitations, and biodiversity and ecosystem responses to elevated CO2. Here we describe the facility and experimental design, and present baseline data collected through the growing season of 2015. These data include: biophysical tree properties; atmospheric CO2/H2O fluxes; airborne and ground laser scatterometry; leaf area index; geophysical survey data; canopy phenology; soil and water chemical and physical properties; and invertebrate surveys. Data from an intensive campaign conducted during august 2015 are also shown, including in- and above- canopy characterisation of biogenic VOCs using a Proton Transfer Reaction Mass Spectrometer, aerosol loading including bioaerosols, and air quality. Further campaign results are presented from leaf level photosynthetic carbon-dioxide response curve (A/Ci) performed at different canopy heights on oak trees, and on the dominant understory species - hazel and sycamore (Acer pseudoplatanus) across the site. BIFoR FACE is intended to be an international facility for forest science - ideas for collaborations are encouraged. Please see http

  16. 2011 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte-Klima-Tagung 2011. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Within the DKV conference of the Deutscher Kaelte- und Klimatechnischer Verein e.V. (Hanover, Federal Republic of Germany) from 16th to 18th November, 2011, at the Eurogress Aachen (Federal Republic of Germany) 112 lectures were held according to the following themes: cryomedicine, cryobiology, cryocomponents, mobility, cryoapplications, miniature cooler, Fundamentals and materials in the cryotechnology and heat pump technology, heat transfer, absorption processes, materials characteristics and phase change materials, storage and phase change, plants and components of refrigerating and heat pump technology - compressors, control and systems, energy efficiency (and CO{sub 2}), standardization and standard, application of refrigeration, supermarket/coolant, enhancement of efficiency in the air conditioning of passenger cars, indoor air conditioning in automobiles, enhancement of efficiency in different vehicles, climate technology and application of heat pumps - field tests and optimization, test rigs and simulations, heat pumps, optimisation in new buildings and stock buildings, climate coolants and quality of air. Beside this conference twelve student meetings were presented.

  17. 2013 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2013. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    These proceedings cover the following main topics: cryoengineering - superconduction / energy storage; cryoapplications in biology and medicine; metrology; adsorption processes; condensation/evaporation; working fluids / simulation; ice production; plants and compressors; expansion and ejectors or recooling; use of cooling (passenger car air conditioning, supermarket); refrigerants; plant efficiency; emissions and legislation; air conditioning and use of heat pumps; air quality and control; building technology and block-type thermal power stations. [German] Dieser Tagungsbericht enthaelt folgende Themenschwerpunkte: Kryotechnik - Supraleitung/Energiespeicher; Kryoanwendungen in der Biologie und Medizin; Messtechnik; Adsorptionsprozesse; Kondensation/Verdampfung; Arbeitsfluide/Simulation; Eiserzeugung; Anlagen und Verdichter; Expansion und Ejektoren bzw. Rueckkuehlung; Kaelteanwendung (PKW-Klimatisierung; Supermarkt); Kaeltemittel; Anlageneffizienz; Emissionen und Gesetzgebung; Klimatechnik und Waermepumpenanwendung; Luftqualitaet und Regelung; Gebaeudetechnik und BHKW.

  18. Ambient air sampling for radioactive air contaminants at Los Alamos National Laboratory: A large research and development facility

    Energy Technology Data Exchange (ETDEWEB)

    Eberhart, C.F.

    1998-09-01

    This paper describes the ambient air sampling program for collection, analysis, and reporting of radioactive air contaminants in and around Los Alamos National Laboratory (LANL). Particulate matter and water vapor are sampled continuously at more than 50 sites. These samples are collected every two weeks and then analyzed for tritium, and gross alpha, gross beta, and gamma ray radiation. The alpha, beta, and gamma measurements are used to detect unexpected radionuclide releases. Quarterly composites are analyzed for isotopes of uranium ({sup 234}U, {sup 235}U, {sup 238}U), plutonium ({sup 238}Pu, {sup 239/249}Pu), and americium ({sup 241}Am). All of the data is stored in a relational database with hard copies as the official records. Data used to determine environmental concentrations are validated and verified before being used in any calculations. This evaluation demonstrates that the sampling and analysis process can detect tritium, uranium, plutonium, and americium at levels much less than one percent of the public dose limit of 10 millirems. The isotopic results also indicate that, except for tritium, off-site concentrations of radionuclides potentially released from LANL are similar to typical background measurements.

  19. Traffic-related air quality assessment for open road tolling highway facility.

    Science.gov (United States)

    Lin, Jie; Yu, Dan

    2008-09-01

    Open road tolling (ORT) design has been considered as an effective means of smoothing highway traffic and reducing travel delay on toll highways. In this paper it is demonstrated that ORT can also achieve significant air quality benefits over the conventional toll plaza design. The near roadside carbon monoxide (CO) concentration levels can be reduced by up to 37%, and diesel particulate matter (DPM) emissions can decrease by as much as 58%. These large expected air quality benefits have great implications to the regional efforts of reducing mobile source air pollution toward achieving attainment status and healthier living environment.

  20. The optimum operating conditions of the phased double-rotor facility at the ET-RR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Naguib, K.; Habib, N.; Wahba, M.; Kilany, M.; Adib, M. [National Research Centre, Cairo (Egypt). Reactor and Neutron Physics Dept.

    1997-02-07

    A pulsed neutron polyenergetic thermal beam at ET-RR-1 is produced by a phased double-rotor facility. One of the rotors has two diametrically opposite curved slots, while the second is designed to operate as a rotating collimator. The dimensions of the phased rotating collimator are selected to match the curved slot rotor. The calculated collimator transmissions at different operating conditions are found to be in good agreement with the experimental ones. The optimum operating conditions of the double-rotor facility are deduced. The calculations were carried out using a computer program RCOL. The RCOL was designed in FORTRAN-77 to operate on PCs. (author).

  1. Solar energy contribution to the energy demand for air conditioning system in an office building under Tripoli climate conditions

    Directory of Open Access Journals (Sweden)

    Musbah Mohamed H.

    2014-01-01

    Full Text Available The feasibility of solar assisted air conditioning in an office building under Tripoli weather conditions is investigated in this paper. A single-effect lithium bromide absorption cycle powered by means of flat-plate solar collectors was modeled in order to predict the potential of the solar energy share. The cooling load profile was generated by using an detailed hourly based program and Typical meteorological year for Tripoli. System performance and solar energy fraction were calculated by varying two major parameters (collector’s slope angle and collector area. The maximum solar fraction of 48% was obtained by means of 1400 m2 of collector surface area. Analysis of results showed that, besides the collector surface area, the main factors affecting the solar fraction were the local weather conditions (intensity of incident solar radiation and the time of day when the plant was operated.

  2. [Study on air quality and pollution meteorology conditions of Guangzhou during the 2010 Asian games].

    Science.gov (United States)

    Li, Ting-Yuan; Deng, Xue-Jiao; Fan, Shao-Jia; Wu, Dui; Li, Fei; Deng, Tao; Tan, Hao-Bo; Jiang, De-Hai

    2012-09-01

    Based on the monitoring data of NO2, O3, SO2, PM, visibility, regional air quality index (RAQI) and the atmospheric transport and diffusion data from Nov. 4, 2010 to Dec. 10, 2010 in Guangzhou area, the variations of air quality and meteorological conditions during the Guangzhou Asian Games were analyzed. It was found that, during the Asian Games, the air quality was better than the air quality before or after the Asian Games. The visibility was greater than the visibility before or after the Asian Games, while the concentrations of PM1 and PM2.5 were lower. The correlation coefficient between visibility and the concentrations of PM1, PM2.5 indicated anti-correlation relationships. Daily and hourly concentrations of NO2 and SO2 met the primary ambient air quality standards, whereas the daily concentration of PM10 and hourly concentration of O3 met the secondary ambient air quality standards. Pollutants had been well controlled during the Asian Games. The concentration of SO2 in Guangzhou was influenced by local sources and long distance transmission, while the concentration of NO2 was significantly influenced by local sources. The emissions of NO2, SO2 and PM10 surrounding Guangzhou had a trend to affect the concentrations in Guangzhou, but the situation of O3 was opposite, the relatively high concentration of O3 in Guangzhou had tendency to be transported to the surrounding areas. The pollution meteorology conditions in the period of Asian Games were better than the conditions before or after the Asian Games. The decrease in the concentrations during the Asian Games did not only benefit from the emission control by the government, but also from the good meteorological conditions.

  3. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    Science.gov (United States)

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning.

  4. Refrigeration and Air Conditioning Equipment, 11-9. Military Curriculum Materials for Vocational and Technical Education.

    Science.gov (United States)

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text consists of three blocks of instructional materials for use by those studying to become refrigeration and air conditioning specialists. Covered in the individual course blocks are the following topics: refrigeration and trouble analysis, thermodynamics, and principles of refrigeration; major components and domestic and…

  5. Refrigeration and Air Conditioning Mechanic: Apprenticeship Course Outline. Apprenticeship and Industry Training. 1411.2

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Refrigeration and Air Conditioning Mechanic apprenticeship training is a journeyman who will: (1) supervise, train and coach apprentices; (2) use and maintain hand and power tools to the standards of competency and safety required in the trade; (3) have a thorough knowledge of the principle components of refrigeration systems,…

  6. An Investigation of Energy Consumption and Cost in Large Air-Conditioned Buildings. An Interim Report.

    Science.gov (United States)

    Milbank, N. O.

    Two similarly large buildings and air conditioning systems are comparatively analyzed as to energy consumption, costs, and inefficiency during certain measured periods of time. Building design and velocity systems are compared to heating, cooling, lighting and distribution capabilities. Energy requirements for pumps, fans and lighting are found to…

  7. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P. [ELF Atochem, Centre d`Application de Lavallois, 92 (France)

    1997-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  8. The new air conditioning wind tunnel at Vienna; Der neue Klima-Wind-Kanal in Wien

    Energy Technology Data Exchange (ETDEWEB)

    Haller, G. [Oesterreichisches Forschungs- und Pruefzentrum Arsenal Ges.m.b.H., Wien (Austria)

    2003-07-01

    The world's only air conditioning wind tunnel for railway vehicles is located in Vienna (Wien Arsenal). For more than 40 years, air conditioning tests, functional tests and reliability tests have been carried out here on components, aggregates, and systems. Applications range from research and development to type testing and certification. In order to cope with future requirements, a new plant is currently being constructed (Pauker-Gruende), also in Vienna. The contribution describes current and future R + D goals in the field of air conditioning simulations for public transportation. On this basis, the specifications on the new air conditioning wind tunnel will be specified. The project and its functionalities are presented. [German] Im weltweit einzigen Klima-Wind-Kanal fuer Schienenfahrzeuge in Wien Arsenal werden seit mehr als 40 Jahren klimatechnische Untersuchungen, Funktions- und Zuverlaessigkeitstests an Komponenten, Aggregaten und am Gesamtsystem durchgefuehrt. Das Dienstleistungsspektrum reicht dabei von der Forschung ueber die Entwicklungsunterstuetzung bis hin zur Typenpruefung und Zertifizierung. Um den technischen Erfordernissen der Zukunft und der notwendigen Flexibilitaetsausweitung zu entsprechen, wird derzeit diese Anlage auf den Pauker-Gruenden in Wien neu errichtet. Der Beitrag beschreibt die derzeitigen und zukuenftigen Forschungs- und Entwicklungsschwerpunkte auf dem Gebiet der Klimasimulation oeffentlicher Verkehrsmittel. Daraus ergeben sich spezielle technische Anforderungen an einen neuen Klima-Wind-Kanal, die unter Einbeziehung der Erfahrungen mit der bestehenden Anlage naeher erlaeutert werden. Abschliessend werden das Ausfuehrungsprojekt selbst und deren erweiterte Moeglichkeiten dargestellt. (orig.)

  9. Application of Dual Throttling Air-Conditioning System to Explosion-Proof Frequency Converter

    Institute of Scientific and Technical Information of China (English)

    张于峰; 高岩; 盛颖

    2015-01-01

    An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inves-tigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning sys-tem was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrig-eration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experi-mental data.

  10. Heating, Air Conditioning and Refrigeration. Vocational Education Curriculum Guide. Industrial and Technical Education.

    Science.gov (United States)

    West Virginia State Vocational Curriculum Lab., Cedar Lakes.

    This curriculum guide contains 17 units that provides the basic curriculum components required to develop lesson plans for the heating, air conditioning, and refrigeration curriculum. The guide is not intended to be a complete, self-contained curriculum, but instead provides the teacher with a number of informational items related to the learning…

  11. Experimental Study on Intelligent Control Scheme for Fan Coil Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Yanfeng Li

    2013-01-01

    Full Text Available An intelligent control scheme for fan coil air-conditioning systems has been put forward in order to overcome the shortcomings of the traditional proportion-integral-derivative (PID control scheme. These shortcomings include the inability of anti-interference and large inertia. An intelligent control test rig of fan coil air-conditioning system has been built, and MATLAB/Simulink dynamics simulation software has been adopted to implement the intelligent control scheme. A software for data exchange has been developed to combine the intelligence control system and the building automation (BA system. Experimental tests have been conducted to investigate the effectiveness of different control schemes including the traditional PID control, fuzzy control, and fuzzy-PID control for fan coil air-conditioning system. The effects of control schemes have been compared and analyzed in robustness, static and dynamic character, and economy. The results have shown that the developed data exchange interface software can induce the intelligent control scheme of the BA system more effectively. Among the proposed control strategies, fuzzy-PID control scheme which has the advantages of both traditional PID and fuzzy schemes is the optimal control scheme for the fan coil air-conditioning system.

  12. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution...

  13. 2012 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte-Klima-Tagung 2012 Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the DKV conference of the Deutscher Kaelte- und Klimatechnischer Verein e.V. (Hanover, Federal Republic of Germany) from 21st to 23rd November, 2012, in Wuerzburg (Federal Republic of Germany) 121 lectures were held according to the following themes: Measurement and process control in cryotechnology; energy storage and energy application; application of cryotechnology in biology and medicine, new concepts and plants; fundamentals and materials for the technology of cold pumps and heat pumps - pool boiling; flow boiling / CO{sub 2}; adsorption processes; adsorption processes / phase change materials; condensation / dehumidification; plants and components of the technology of cold pumps and heat pumps - compressors; expansion and regulation; heat exchanger and reflux cooling; heat exchangers; systems simulation; systems and materials; application of cold - energy controlling / application; foodstuff / supermarket; air conditionings of passenger cars; air-conditioning of electric-powered automobiles; railway air-conditioning / system analyses; standardization and regulations; air conditioning and application of heat pumps - regulation / hardware-in-the-loop; net-zero-energy building; building engineering and simulation; standardization / IAQ / building materials; heat pumps; thermal comfort and performance in office accommodations.

  14. Performance of residential air-conditioning systems with flow maldistribution in fin-and-tube evaporators

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Refrigerant and airflow maldistribution in fin-and-tube evaporators for residential air-conditioning was investigated with numerical modeling. Fin-and-tube heat exchangers usually have a pre-defined circuitry. However, the objective in this study was to perform a generic investigation of each...

  15. Exploring policy strategies for mitigating HFC emissions from refrigeration and air conditioning

    NARCIS (Netherlands)

    Hekkenberg, M.; Uiterkamp, Anton J. M. Schoot

    2007-01-01

    The growing demand for cooling throughout the world, possibly increased by global climate change, requires the implementation of policies to mitigate the related greenhouse gas (GHG) emissions from energy and refrigerant use in the refrigeration and air conditioning (RAC) sector. This article aims t

  16. Research on performance of mixed absorption refrigeration for solar air-conditioning

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A novel lithium bromide/water mixed absorption refrigeration cycle that is suitable for the utilization of solar air-conditioning and can overcome the drawbacks of low system overall efficiency of traditional solar absorption refrigeration air-condition systems is presented.The accessorial high pressure generator was added in the cycle.The lithium bromide solution flowing out from the high pressure generator was mixed with the solution from the low pressure absorber to increase lithium bromide solution concentration and decrease pressure in the high pressure absorber.The performance of a mixed absorption refrigeration cycle was analyzed.The theoretical analysis shows that the highest COP is 0.61,while the highest available temperature difference of heat resource is 33.2℃.The whole coefficient of performance of the solar air-conditioning using mixed absorption cycle is 94.5% higher than that of two-stage absorption.The advantages of solar air-conditioning can be markedly made use of by the cycle.

  17. Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air conditioning technology workshop

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    Sessions included: HFC blown polyurethanes, carbon dioxide blown foam and extruded polystyrenes, plastic foam insulations, evacuated panel insulation, refrigeration and air conditioning, absorption and adsorption and stirling cycle refrigeration, innovative cooling technologies, and natural refrigerants. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  18. Air conditioning a vaccine laboratory. [Connaught Medical Research Laboratory, Toronto, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Ross J.

    1976-05-01

    In 1974, the new Bacterial Vaccine Building of Connaught Medical Research Laboratories, Toronto, Canada, was opened to produce such vaccines as pertussis, typhoid, paratyphoids, and cholera and such toxoids as staphylococcus, diphtheria, and tetanus. It also produces other medicinal products. The layout of the complex and the air conditioning system necessary in all zones are described and schematically shown. (MCW)

  19. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  20. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  1. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Instructor Edition. Introduction to Construction Series.

    Science.gov (United States)

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This instructor's guide contains the materials required to teach a competency-based introductory course in heating, ventilating, and air conditioning (HVAC) to students who have chosen to explore careers in construction. It contains three units: HVAC materials, HVAC tools, and applied skills. Each instructional unit includes some or all of the…

  2. Introduction to Heating, Ventilation and Air Conditioning (HVAC). Introduction to Construction Series. Instructor Edition.

    Science.gov (United States)

    Associated General Contractors of America, Washington, DC.

    This module on introductory heating, ventilating, and air conditioning (HVAC) is one of a series of modules designed to teach basic skills necessary for entry-level employment in this field. The module contains four instructional units that cover the following topics: (1) HVAC materials; (2) HVAC tools; (3) HVAC layout; and (4) HVAC basic skills.…

  3. Geothermal as a heat sink application for raising air conditioning efficency

    Science.gov (United States)

    Ibrahim, Hesham Safwat Osman Mohamed

    2016-04-01

    Objective: Geothermal applications in heating, ventilation, air-conditioning is a US technology for more than 30 years old ,which saves more than 30% average energy cost than the traditional air-conditioning systems systems. Applying this technology in Middle East and African countries would be very feasible specially in Egypt specially as it suffers Electric crisis --The temperature of the condensers and the heat rejecting equipment is much higher than the Egyptian land at different depth which is a great advantages, and must be measured, recorded, and studied accurately -The Far goal of the proposal is to construct from soil analysis a temperature gradient map for Egypt and , African countries on different depth till 100 m which is still unclear nowadays and must be measured and recorded in databases through researches - The main model of the research is to study the heat transfer gradient through the ground earth borehole,grout,high density polyethylene pipes , and water inlet temperature which affect the electric efficiency of the ground source heat pump air conditioning unit Impact on the Region: Such research result will contribute widely in Energy saving sector specially the air conditioning sector in Egypt and the African countries which consumes more than 30% of the electric consumption of the total consumption . and encouraging Green systems such Geothermal to be applied

  4. Comparative economic assessment of the energy performance of air-conditioning within the Mexican residential sector

    Directory of Open Access Journals (Sweden)

    Ivan Oropeza-Perez

    2016-11-01

    Full Text Available This work shows a sensitivity analysis of the economic impact of different energy performances of air-conditioning within the Mexican housing sector. For this purpose, a cooling-load calculator program in function of the indoor temperature is developed. The program also calculates the electricity consumption along with the expenditure with the different residential rates of the Mexican Federal Commission of Electricity (CFE, initials in Spanish set according to the season of the year and zone of the country. After the results onto the national-scale scenario are validated with the literature, a sensitivity analysis is carried out by changing three parameters that are considered as influential on the consumption and which can be considered as energy saving strategies. With these strategies, it is found that the indoor temperature decrease due to the use of a passive cooling system is the most important characteristic to take into account followed by the coefficient of performance (COP of the air-conditioning and the increase of the comfort temperature set-point, respectively. Thereby, an economic analysis is carried out, finding an annual saving up to 770 USD within a single air-conditioned dwelling having a payback period of 3 years for using a combination of passive cooling techniques and increasing the comfort temperature set-point; or a 2 years payback period if the air-conditioning is changed by a high-efficient equipment.

  5. 76 FR 17487 - Protection of Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector...

    Science.gov (United States)

    2011-03-29

    ... Governments G. Executive Order 13045: Protection of Children From Environmental Health and Safety Risks H... Science and Technology of Japan ASHRAE--American Society for Heating, Refrigerating, and Air- Conditioning... connect refrigerant containers to the MVAC system; a warning label indicating the refrigerant's identity...

  6. 空调列车内空气品质改善途径探讨%Approaching Ways to Improve Air Quality of Air-conditioning Train

    Institute of Scientific and Technical Information of China (English)

    李红民

    2011-01-01

    Strengthening fresh air effect is one of the best ways to improve air quality of air-conditioning train in our country. In view of the problems exiting in fresh air treatment of the current passenger train air conditioning system, setting up independent fresh air treatment system and sending high quality fresh air to passenger directly is supposed to attain that goal.%加强新风效应是改善我国铁路空调客车空气品质最有效的途径之一。针对现有的客车空调系统在处理新风上存在的问题,提出设置独立的新风处理系统,将高品质的新风直接送入乘客呼吸区,以达到加强新风效应的目的。

  7. Environmental Assessment (EA): Proposed Software Facilities, Hill Air Force Base, Utah

    Science.gov (United States)

    2011-04-19

    for hazardous air pollutants (HAPs). Solid and Hazardous Waste If contaminated building materials, soils or pavements are identified, they...and the extensive development and disturbance of Hill AFB, the potential for historic properties is extremely low . However, if any such properties are...painting and abrasive blasting operations (in compliance with the base’s Title V air quality permit). Emission estimates are available for criteria

  8. Environmental Assessment for Developing Renewable Energy Enhanced Use Lease Facilities at Robins Air Force Base

    Science.gov (United States)

    2013-12-15

    and effluent is monitored for biological oxygen demand, chemical oxygen demand, coliform bacteria, pH, oil and grease, ammonia , metals, suspended...on Airports and Aviation. Airport Cooperative Research Program. ACRP Synthesis 28. United States Air Force (USAF). 2013. U.S. Air Force Energy...battlegrounds, and a variety of other structures from the period of recorded history in the region. Architectural resources include structures or districts

  9. Heavy metal contamination in an urban stream fed by contaminated air-conditioning and stormwater discharges.

    Science.gov (United States)

    O'Sullivan, Aisling; Wicke, Daniel; Cochrane, Tom

    2012-03-01

    Urban waterways are impacted by diffuse stormwater runoff, yet other discharges can unintentionally contaminate them. The Okeover stream in Christchurch, New Zealand, receives air-conditioning discharge, while its ephemeral reach relies on untreated stormwater flow. Despite rehabilitation efforts, the ecosystem is still highly disturbed. It was assumed that stormwater was the sole contamination source to the stream although water quality data were sparse. We therefore investigated its water and sediment quality and compared the data with appropriate ecotoxicological thresholds from all water sources. Concentrations of metals (Zn, Cu and Pb) in stream baseflow, stormwater runoff, air-conditioning discharge and stream-bed sediments were quantified along with flow regimes to ascertain annual contaminant loads. Metals were analysed by ICP-MS following accredited techniques. Zn, Cu and Pb concentrations from stormflow exceeded relevant guidelines for the protection of 90% of aquatic species by 18-, 9- and 5-fold, respectively, suggesting substantial ecotoxicity potential. Sporadic copper (Cu) inputs from roof runoff exceeded these levels up to 3,200-fold at >4,000 μg L⁻¹ while Cu in baseflow from air-conditioning inputs exceeded them 5.4-fold. There was an 11-fold greater annual Cu load to the stream from air-conditioning discharge compared to stormwater runoff. Most Zn and Cu were dissolved species possibly enhancing metal bioavailability. Elevated metal concentrations were also found throughout the stream sediments. Environmental investigations revealed unsuspected contamination from air-conditioning discharge that contributed greater Cu annual loads to an urban stream compared to stormwater inputs. This discovery helped reassess treatment strategies for regaining ecological integrity in the ecosystem.

  10. Air conditioning and intrahospital mortality during the 2003 heatwave in Portugal: evidence of a protective effect.

    Science.gov (United States)

    Nunes, Baltazar; Paixão, Eleonora; Dias, Carlos Matias; Nogueira, Paulo; Marinho Falcão, José

    2011-03-01

    The objective of the study was to analyse the association between the presence of air conditioning in hospital wards and the intrahospital mortality during the 2003 heatwave, in mainland Portugal. Historical cohort study design including all patients aged 45 or more who were hospitalised in the 7 days before the heatwave. The outcome was survival during the 18 days the heatwave lasted and during the 2 days after the end of the heatwave. A comparison group was also selected in four analogous periods without any heatwave event during January to May 2003. Data were obtained from the 2003 hospital discharges database. Air conditioning presence in hospital wards was determined using a survey sent to hospital administrations. A Cox-regression model was used to estimate the confounder-adjusted HR of death, during the heatwave and the comparison period, in patients in wards with air conditioning (AC+) versus patients in wards without air conditioning (AC-). 41 hospitals of mainland Portugal (49% of all hospitals in mainland Portugal) participated, and 2093 patients were enrolled. The overall confounder-adjusted HR of death in AC+ patients versus AC- patients was 0.60 (95% CI 0.37 to 0.97) for the heatwave period and 1.05 (95% CI 0.84 to 1.32) for the comparison group. The study found strong evidence that, during the August 2003 heatwave, the presence of air conditioning in hospital wards was associated with an increased survival of patients admitted before the beginning of the climate event. The reduction of the risk of dying is estimated to be 40% (95% CI 3% to 63%).

  11. Saving 50% of energy in air conditioning and refrigeration; 50% de ahorro de energia en aire acondicionado y refrigeracion

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez De la Fuente, Rodolfo Javier [Instituto para la Proteccion Ambiental de Nuevo Leon-CAINTRA, Nuevo Leon (Mexico); Bolado Tamez, Jaime Antonio [Industrias AlEn S. A. de C. V., Monterrey (Mexico)

    1998-12-31

    Due to the fact that the air conditioning systems represent up to 70% of the energy consumption in our buildings, to the constant raise of the electric tariffs and to the increment of temperatures in Nuevo Leon State, as well as the restrictions on the use of some refrigerant fluids because of its potential damage to the ozone layer (Montreal Protocol) and the preferential use of refrigerants with low global heating potential (Kioto Protocol). The Camara de la Industria de la Transformacion de Nuevo Leon (Nuevo Leon`s Transformation Industry Chamber) through the Instituto para la Proteccion Ambiental de Nuevo Leon (Nuevo Leon`s Institute for Environmental Protection), create the program ECO-REFRIGERATION whose three missions are: Increase the efficiency of air conditioning and refrigeration equipment, promote the substitution of refrigerants and extend the benefits of these projects to the community in general. [Espanol] Debido a que los sistemas de climatizacion representan hasta el 70% de consumo energetico en nuestros inmuebles, al constante incremento de las tarifas electricas, el incremento de las temperaturas en Nuevo Leon, asi como la restriccion del uso de algunos refrigerantes por su potencial de dano de la capa de ozono (Protocolo de Montreal) y el uso preferente de refrigerantes con bajo potencial de calentamiento global (Protocolo de Kioto), la Camara de la Industria de la Transformacion de Nuevo Leon a traves del Instituto para la Proteccion Ambiental de Nuevo Leon crean el Programa ECO-REFRIGERACION cuyas tres misiones son: Incrementar la eficiencia de los equipos de aire acondicionado y refrigeracion, promover la sustitucion de refrigerantes y extender los beneficios de este proyecto a la comunidad en general.

  12. Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System

    Institute of Scientific and Technical Information of China (English)

    WANG Jiangjiang; AN Dawei; ZHANG Chunfa; JING Youyin

    2009-01-01

    Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multi-variable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified l0 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control.

  13. 42 CFR 483.450 - Condition of participation: Client behavior and facility practices.

    Science.gov (United States)

    2010-10-01

    ... available to all staff, clients, parents of minor children, and legal guardians. (2) To the extent possible...: Facility practices—Conduct toward clients. (1) The facility must develop and implement written policies and... specifically towards the reduction of and eventual elimination of the behaviors for which the drugs...

  14. Performance and evaluation of gas engine driven rooftop air conditioning equipment at the Willow Grove (PA) Naval Air Station

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Conover, D.R.

    1993-05-01

    In a field evaluation conducted for the US Department of Energy (DOE) Office of Federal Energy Management Program (FEMP), the Pacific Northwest Laboratory (PNL) examined the performance of a new US energy-related technology under the FEMP Test Bed Demonstration Program. The technology was a 15-ton natural gas engine driven roof top air conditioning unit. Two such units were installed on a naval retail building to provide space conditioning to the building. Under the Test Bed Demonstration Program, private and public sector interests are focused to support the installation and evaluation of new US technologies in the federal sector. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) with DOE were the American Gas Cooling Center, Philadelphia Electric Company, Thermo King Corporation, and the US Naval Air Station at Willow Grove, Pennsylvania. Equipment operating and service data as well as building interior and exterior conditions were secured for the 1992 cooling season. Based on a computer assessment of the building using standard weather data, a comparison was made with the energy and operating costs associated with the previous space conditioning system. Based on performance during the 1992 cooling season and adjusted to a normal weather year, the technology will save the site $6,000/yr in purchased energy costs. An additional $9,000 in savings due to electricity demand ratchet charge reductions will also be realized. Detailed information on the technology, the installation, and the results of the technology test are provided to illustrate the advantages to the federal sector of using this technology. A history of the CRADA development process is also reported.

  15. Influence of indoor air conditions on radon concentration in a detached house.

    Science.gov (United States)

    Akbari, Keramatollah; Mahmoudi, Jafar; Ghanbari, Mahdi

    2013-02-01

    Radon is released from soil and building materials and can accumulate in residential buildings. Breathing radon and radon progeny for extended periods hazardous to health and can lead to lung cancer. Indoor air conditions and ventilation systems strongly influence indoor radon concentrations. This paper focuses on effects of air change rate, indoor temperature and relative humidity on indoor radon concentrations in a one family detached house in Stockholm, Sweden. In this study a heat recovery ventilation system unit was used to control the ventilation rate and a continuous radon monitor (CRM) was used to measure radon levels. FLUENT, a computational fluid dynamics (CFD) software package was used to simulate radon entry into the building and air change rate, indoor temperature and relative humidity effects using a numerical approach. The results from analytical solution, measurements and numerical simulations showed that air change rate, indoor temperature and moisture had significant effects on indoor radon concentration. Increasing air change rate reduces radon level and for a specific air change rate (in this work Ach = 0.5) there was a range of temperature and relative humidity that minimized radon levels. In this case study minimum radon levels were obtained at temperatures between 20 and 22 °C and a relative humidity of 50-60%.

  16. Open absorption system for cooling and air conditioning using membrane contactors - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Conde-Petit, M. [M. Conde Engineering, Zuerich (Switzerland); Weber, R.; Dorer, V. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland)

    2008-07-01

    Air conditioning systems based upon the open absorption principle, essentially an absorption device operating at atmospheric pressure, have been proposed and investigated at many instances in the past eighty years. Their potential for improving energy efficiency is clearly recognized in the earliest research reports. By the mid 1950ies, solar thermal energy was being applied to drive open absorption-based air conditioning systems. For several reasons, however, the open absorption technology was not mature enough to take place in the mainstream. In the past two decades, vigorous efforts have been undertaken to reverse this situation, but success continued to elude, despite the fact that the main problems, such as corrosion, aerosols in the supply air, etc., have been identified. This report details the work and the main results from the MemProDEC Project. In this project innovative solutions were proposed, and successfully investigated, for the corrosion problem and the improvement of efficiency of the absorption process, in particular a new method to cool a very compact absorber. The practically uniform flow distribution for all three streams in the absorber (air, water and desiccant) warrants the contact of the air to be dehumidified with the desiccant over the whole surface of exchange (across a porous membrane). This, together with the cooling with water in counter flow to the air, are the key factors for the excellent effectiveness of the absorber. As the results show, the dehydration effectiveness of the prototype absorber is up to 150 % higher than that previously obtained by others. The solutions developed for compactness and modularity represent an important step in the way to flexible manufacturing, i.e. using a single element size to assemble autonomous air handling units of various nominal capacities. And although the manufacturing methods of the individual elements require improvement, namely by avoiding adhesive bonding, the choice of materials and the

  17. Development and analysis of an economizer control strategy algorithm to promote an opportunity for energy savings in air conditioning installations

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M.; Azevedo, Walter L. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefetmg.br

    2000-07-01

    This work presents an algorithm control strategy denominated enthalpy economizer. The objective of this algorithm strategy is to determine the adequate fractions of outside and return air flowrates entering a cooling coil based on the analysis of the outside, return and supply air enthalpies, rather than on the analysis of the dry bulb temperatures. The proposed algorithm predicts the actual opening position of the outside and return air dampers in order to provide the lower mixing air enthalpy. First, the psychometrics properties of the outside and return air are calculated from actual measurements of the dry and wet bulb temperatures. Then, three distinct cases are analyzed: the enthalpy of the outside air is lower than the enthalpy of the supply air (free cooling); the enthalpy of the outside air is higher than the enthalpy of the return air; the enthalpy of the outside air is lower than the enthalpy of the return air and higher than the temperature of the supply air. Different outside air conditions were selected in order to represent typical weather data of Brazilians cities, as well as typical return air conditions. It was found that the enthalpy control strategy could promote an opportunity for energy savings mainly during mild nights and wintertime periods as well as during warm afternoons and summertime periods, depending on the outside air relative humidity. The proposed algorithm works well and can be integrated in some commercial automation software to reduce energy consumption and electricity demand. (author)

  18. Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yueming; Wu, Jingyi [Shanghai Jiao Tong University, Institute of Refrigeration and Cryogenics (China); Shiochi, Sumio [Daikin Industries Ltd. (Japan)

    2009-09-15

    As a new system, variable refrigerant flow system with water-cooled condenser (water-cooled VRF) can offer several interesting characteristics for potential users. However, at present, its dynamic simulation simultaneously in association with building and other equipments is not yet included in the energy simulation programs. Based on the EnergyPlus's codes, and using manufacturer's performance parameters and data, the special simulation module for water-cooled VRF is developed and embedded in the software of EnergyPlus. After modeling and testing the new module, on the basis of a typical office building in Shanghai with water-cooled VRF system, the monthly and seasonal cooling energy consumption and the breakdown of the total power consumption are analyzed. The simulation results show that, during the whole cooling period, the fan-coil plus fresh air (FPFA) system consumes about 20% more power than the water-cooled VRF system does. The power comparison between the water-cooled VRF system and the air-cooled VRF system is performed too. All of these can provide designers some ideas to analyze the energy features of this new system and then to determine a better scheme of the air conditioning system. (author)

  19. Fuel Performance Characterisation under Various PWR Conditions: Description of the Annealing Test Facilities available at the LECA-STAR laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Pontillon, Y.; Cornu, B.; Clement, S.; Ferroud-Plattet, M.P.; Malgouyres, P.P. [Commissariat a l' Energie Atomique, CEA/DEN/DEC/SA3C - Centre d' Etudes de Cadarache, BP1, 13108 Saint Paul Lez Durance (France)

    2008-07-01

    The aim to improve LWR fuel behaviour has led Cea to improve its post-irradiation examination capacities in term of test facilities and characterization techniques in the shielded hot cells of the LECA-STAR facility, located in Cadarache Cea center. as far as the annealing test facilities are concerned, fuel qualification and improvement of knowledge require a set of furnaces which are already used or will be used. The main characteristics of these furnaces strongly depend on the experimental objectives. The aim of this paper is to review the main aspects of these specific experiments concerning: (i) fission gas release from high burn up fuel, (ii) global fission product release in severe-accident conditions and (iii) fuel microstructural changes, potential cladding failure, radionuclide source terms... under conditions representative of long term dry storage and geological disposal. (authors)

  20. TNO HVAC facilities

    NARCIS (Netherlands)

    Hammink, H.A.J.

    2015-01-01

    TNO has extensive knowledge of heating, ventilation and air conditioning (HVAC), and can offer its services through theoretical studies, laboratory experiments and field measurements. This complete scope, made possible through our test facilities, enables the effective development of new products, i