WorldWideScience

Sample records for eyes electronic resource

  1. Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment

    International Nuclear Information System (INIS)

    Shiu, Almon S.; Tung, Samuel S.; Gastorf, Robert J.; Hogstrom, Kenneth R.; Morrison, William H.; Peters, Lester J.

    1996-01-01

    Purpose: The purpose of this study is to report that commercially available eye shields (designed for orthovoltage x-rays) are inadequate to protect the ocular structures from penetrating electrons for electron beam energies equal to or greater than 6 MeV. Therefore, a prototype medium size tungsten eye shield was designed and fabricated. The advantages of the tungsten eye shield over lead are discussed. Methods and Materials: Electron beams (6-9 MeV) are often used to irradiate eyelid tumors to curative doses. Eye shields can be placed under the eyelids to protect the globe. Film and thermoluminescent dosimeters (TLDs) were used within a specially constructed polystyrene eye phantom to determine the effectiveness of various commercially available internal eye shields (designed for orthovoltage x-rays). The same procedures were used to evaluate a prototype medium size tungsten eye shield (2.8 mm thick), which was designed and fabricated for protection of the globe from penetrating electrons for electron beam energy equal to 9 MeV. A mini-TLD was used to measure the dose enhancement due to electrons backscattered off the tungsten eye shield, both with or without a dental acrylic coating that is required to reduce discomfort, permit sterilization of the shield, and reduce the dose contribution from backscattered electrons. Results: Transmission of a 6 MeV electron beam through a 1.7 mm thick lead eye shield was found to be 50% on the surface (cornea) of the phantom and 27% at a depth of 6 mm (lens). The thickness of lead required to stop 6-9 MeV electron beams is impractical. In place of lead, a prototype medium size tungsten eye shield was made. For 6 to 9 MeV electrons, the doses measured on the surface (cornea) and at 6 mm (lens) and 21 mm (retina) depths were all less than 5% of the maximum dose of the open field (4 x 4 cm). Electrons backscattered off a tungsten eye shield without acrylic coating increased the lid dose from 85 to 123% at 6 MeV and 87 to 119% at

  2. Resources for eye care at secondary and tertiary level government institutions in Saudi Arabia.

    Science.gov (United States)

    Al Motowa, Saeed; Khandekar, Rajiv; Al-Towerki, Abdulelah

    2014-01-01

    To evaluate the number of healthcare personnel and equipment resources for eye care at government institutions in different administrative zones of the Kingdom of Saudi Arabia (KSA) and to recommend measures for increasing resources to address deficiencies. Data on resources (personnel and equipment) for eye care were collected from all governmental eye units in 2012. The data was regrouped by zones and administrative areas. The mid-2012 population projections were used to calculate the ophthalmologist to population ratio and optometrist to population ratio. The equipment available for eye care was reviewed. All 60 institutions in 13 administrative areas and five zones of KSA participated in this study. There were 407 ophthalmologists and 147 optometrists. The ophthalmologist to population ratio was 1:43,000 (1:12,900 in the northern zone to 1:80,300 in the western zone). By 2015, 700 ophthalmologists will be required, and by 2020, 1,100 ophthalmologists will be required. The optometrist to population ratio was 1:95,000 (1:34,100 in the northern zone to 1:146,700 in the western zone). Nearly 2,800 and 4,400 allied eye care personnel will be needed by 2015 and 2020. Diagnostic and treatment equipment such as lasers, electrophysiologic and ultrasound equipment, and fundus cameras were not available at all institutions. Data from the private sector need to be included to draw conclusions on the human resource index for eye care in the Kingdom. An unequal distribution of resources in different zones and administrative areas requires attention. Better utilization of available resources is recommended before fulfilling the demand for additional resources.

  3. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  4. Material Resources For Eye Care Delivery In Urban South-Eastern ...

    African Journals Online (AJOL)

    Objectives: To determine the availability and distribution of material resources for primary and secondary level eye care delivery in Enugu-North Local Government Area (LGA) of Enugu State. Methods: A survey of Public (State and Local Government administered) health care facilities in Enugu North LGA was done.

  5. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  6. Feasibility of utilizing a commercial eye tracker to assess electronic health record use during patient simulation.

    Science.gov (United States)

    Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu

    2016-09-01

    Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.

  7. Use of Electronic Health Records and Administrative Data for Public Health Surveillance of Eye Health and Vision-Related Conditions

    Science.gov (United States)

    Elliott, Amanda; Davidson, Arthur; Lum, Flora; Chiang, Michael; Saaddine, Jinan B; Zhang, Xinzhi; Crews, John E.; Chou, Chiu-Fang

    2014-01-01

    Purpose To discuss the current trend toward greater use of electronic health records and how these records could enhance public health surveillance of eye health and vision-related conditions. Methods We describe three currently available sources of electronic health data (Kaiser Permanente, the Veterans Health Administration, and the Centers for Medicare & Medicaid Services) and how these sources can contribute to a comprehensive vision and eye health surveillance system. Results Each of the three sources of electronic health data can contribute meaningfully to a comprehensive vision and eye health surveillance system, but none currently provide all the information required. The use of electronic health records for vision and eye health surveillance has both advantages and disadvantages. Conclusions Electronic health records may provide additional information needed to create a comprehensive vision and eye health surveillance system. Recommendations for incorporating electronic health records into such a system are presented. PMID:23158225

  8. Electronic eye occluder with time-counting and reflection control

    Science.gov (United States)

    Karitans, V.; Ozolinsh, M.; Kuprisha, G.

    2008-09-01

    In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.

  9. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  10. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  11. Application of a dummy eye shield for electron treatment planning

    International Nuclear Information System (INIS)

    Kang, Sei-Kwon; Park, Soah; Hwang, Taejin; Cheong, Kwang-Ho; Han, Taejin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik

    2013-01-01

    Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size as the tungsten eye shield was machined and CT scanned. The BEAMnrc and the DOSXYZnrc were used for the Monte Carlo (MC) simulation, with the appropriate material information and density for the aluminum cover, steel knob and tungsten body of the eye shield. The Pinnacle adopting the Hogstrom electron pencil-beam algorithm was used for the one-port 6-MeV beam plan after delineation and density override of the metallic parts. The results were confirmed with the metal oxide semiconductor field effect transistor (MOSFET) detectors and the Gafchromic EBT2 film measurements. For both the maximum eyelid dose over the shield and the maximum dose under the shield, the MC results agreed with the EBT2 measurements within 1.7%. For the Pinnacle plan, the maximum dose under the shield agreed with the MC within 0.3%; however, the eyelid dose differed by -19.3%. The adoption of the acrylic dummy eye shield was successful for the treatment plan. However, the Pinnacle pencil-beam algorithm was not sufficient to predict the eyelid dose on the tungsten shield, and more accurate algorithms like MC should be considered for a treatment plan. (author)

  12. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  13. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  14. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  15. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  16. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  17. Use of electronic health records and administrative data for public health surveillance of eye health and vision-related conditions in the United States.

    Science.gov (United States)

    Elliott, Amanda F; Davidson, Arthur; Lum, Flora; Chiang, Michael F; Saaddine, Jinan B; Zhang, Xinzhi; Crews, John E; Chou, Chiu-Fang

    2012-12-01

    To discuss the current trend toward greater use of electronic health records and how these records could enhance public health surveillance of eye health and vision-related conditions. Perspective, comparing systems. We describe 3 currently available sources of electronic health data (Kaiser Permanente, the Veterans Health Administration, and the Centers for Medicare & Medicaid Services) and how these sources can contribute to a comprehensive vision and eye health surveillance system. Each of the 3 sources of electronic health data can contribute meaningfully to a comprehensive vision and eye health surveillance system, but none currently provide all the information required. The use of electronic health records for vision and eye health surveillance has both advantages and disadvantages. Electronic health records may provide additional information needed to create a comprehensive vision and eye health surveillance system. Recommendations for incorporating electronic health records into such a system are presented. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  19. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  20. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  1. Setting targets for human resources for eye health in sub-Saharan Africa: what evidence should be used?

    Science.gov (United States)

    Courtright, Paul; Mathenge, Wanjiku; Kello, Amir Bedri; Cook, Colin; Kalua, Khumbo; Lewallen, Susan

    2016-03-16

    With a global target set at reducing vision loss by 25% by the year 2019, sub-Saharan Africa with an estimated 4.8 million blind persons will require human resources for eye health (HReH) that need to be available, appropriately skilled, supported, and productive. Targets for HReH are useful for planning, monitoring, and resource mobilization, but they need to be updated and informed by evidence of effectiveness and efficiency. Supporting evidence should take into consideration (1) ever-changing disease-specific issues including the epidemiology, the complexity of diagnosis and treatment, and the technology needed for diagnosis and treatment of each condition; (2) the changing demands for vision-related services of an increasingly urbanized population; and (3) interconnected health system issues that affect productivity and quality. The existing targets for HReH and some of the existing strategies such as task shifting of cataract surgery and trichiasis surgery, as well as the scope of eye care interventions for primary eye care workers, will need to be re-evaluated and re-defined against such evidence or supported by new evidence.

  2. Evaluation of eye shields made of tungsten and aluminum in high-energy electron beams

    International Nuclear Information System (INIS)

    Weaver, Randi D.; Gerbi, Bruce J.; Dusenbery, Kathryn E.

    1998-01-01

    Purpose: To protect the lens and cornea of the eye when treating the eyelid with electrons, we designed a tungsten and aluminum eye shield that protected both the lens and cornea, and also limited the amount of backscatter to the overlying eyelid when using electron beam therapy. Methods and Materials: Custom curved tungsten eye shields, 2 mm and 3 mm thick, were placed on Kodak XV film on 8 cm polystyrene and irradiated to evaluate the transmission through the shields. To simulate the thickness of the eyelid and to hold the micro-TLDs, an aquaplast mold was made to match the curvature of the eye shields. Backscatter was measured by placing the micro-TLDs on the beam entrance side to check the dose to the underside of the eyelid. Measurements were done with no aluminum, 0.5, and 1.0 mm of aluminum on top of the tungsten eye shields. The measurements were repeated with 2- and 3-mm flat pieces of lead to determine both the transmission and the backscatter dose for this material. Results: Tungsten proved to be superior to lead for shielding the underlying structures and for reducing backscatter. At 6 MeV, a 3-mm flat slab of tungsten plus 0.5 mm of aluminum, resulted in .042 Gy under the shield when 1.00 Gy is delivered to d max . At 6 MeV for a 3-mm lead plus 0.5-mm aluminum, .046 Gy was measured beneath the shield, a 9.5% decrease with the tungsten. Backscatter was also decreased from 1.17 to 1.13 Gy, a 4% decrease, when using tungsten plus 0.5 mm of aluminum vs. the same thickness of lead. Measurements using 9 MeV were performed in the same manner. With 3 mm tungsten and 0.5 mm of aluminum, at 3 mm depth the dose was .048 Gy compared to .079 Gy with lead and aluminum (39% decrease). Additionally, the backscatter dose was 3% less using tungsten. Simulating the lens dose 3 mm beyond the shield for the 2-mm and 3-mm custom curved tungsten eye shields plus 0.5 mm of aluminum was .030 and .024 Gy, respectively, using 6 MeV (20% decrease). Using 9-MeV electrons, the dose

  3. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    Science.gov (United States)

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  4. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    International Nuclear Information System (INIS)

    Nogueira, P; Vaz, P; Zankl, M; Schlattl, H

    2011-01-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  5. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  6. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  7. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  8. use of electronic resources by graduate students of the department

    African Journals Online (AJOL)

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  9. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  10. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  11. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  12. Estimation of deep, eye lens and skin doses for high energy electron beams for dosimetry and protection purpose

    International Nuclear Information System (INIS)

    Reena Kumari; Rakesh, R.B.

    2018-01-01

    In the radiological protection especially for individual as well as area monitoring, it is generally considered that beta sources deposit skin and eye lens doses only as they do not have enough energy for depositing doses at 10 mm depth. Also, the skin and eye lens doses differ substantially due to attenuation of beta particles at 0.07 mm (skin) and 3 mm (eye lens) depths and the surface doses are always greater than eye lens doses even for the highest energy beta source used in brachytherapy applications. However, worldwide increase in the use of high energy electron accelerators, new challenges are being posed for radiological protection and the operational quantities defined previously by ICRU are being reviewed. In view of these developments, studies have been performed for different electron beams in the energy range from (4 - 20) MeV generated using a medical linear accelerator. The aim of the study is to measure doses deposited at various depths as defined by ICRU 39 for individual and area monitoring purposes

  13. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  14. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  15. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Directory of Open Access Journals (Sweden)

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  16. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  17. The "EyeCane", a new electronic travel aid for the blind: Technology, behavior & swift learning.

    Science.gov (United States)

    Maidenbaum, Shachar; Hanassy, Shlomi; Abboud, Sami; Buchs, Galit; Chebat, Daniel-Robert; Levy-Tzedek, Shelly; Amedi, Amir

    2014-01-01

    Independent mobility is one of the most pressing problems facing people who are blind. We present the EyeCane, a new mobility aid aimed at increasing perception of environment beyond what is provided by the traditional White Cane for tasks such as distance estimation, navigation and obstacle detection. The "EyeCane" enhances the traditional White Cane by using tactile and auditory output to increase detectable distance and angles. It circumvents the technical pitfalls of other devices, such as weight, short battery life, complex interface schemes, and slow learning curve. It implements multiple beams to enables detection of obstacles at different heights, and narrow beams to provide active sensing that can potentially increase the user's spatial perception of the environment. Participants were tasked with using the EyeCane for several basic tasks with minimal training. Blind and blindfolded-sighted participants were able to use the EyeCane successfully for distance estimation, simple navigation and simple obstacle detection after only several minutes of training. These results demonstrate the EyeCane's potential for mobility rehabilitation. The short training time is especially important since available mobility training resources are limited, not always available, and can be quite expensive and/or entail long waiting periods.

  18. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Directory of Open Access Journals (Sweden)

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  19. Preservation and conservation of electronic information resources of ...

    African Journals Online (AJOL)

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  20. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  1. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  2. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  3. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  4. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  5. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  6. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  7. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  8. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  9. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  10. Why and How to Measure the Use of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  11. Comparison of eye shields in radiotherapeutic beams

    International Nuclear Information System (INIS)

    Currie, B.E.; Wellington Hospital, Wellington; Johnson, A.D.

    2004-01-01

    Full text: Both MeV electrons and kV photons are used in the treatment of superficial cancers. The advantages and disadvantages for each of these modalities have been widely reported in the literature (See for example [1-2]). Of particular note in the literature is the use of lead and tungsten eye shields to protect ocular structures during radiotherapy. An investigation addressing issues raised in the literature that are relevant to the Wellington Cancer Centre method of treatment of lesions near the eye shall be summarised. Various small sized fields were irradiated to determine depth dose and profile curves in a water phantom shielded by various commercially available eye shields. Transmission factors relevant to critical ocular structures and particle distribution theories are used to further elucidate the comparison between the use of MeV electrons and kV photons in the treatment of superficial cancers. Superficial X-rays from a Pantak Therapax unit SXT 150 model of HVL 4.90mm Al were used for the lead eye shield measurements and electrons from a Varian Clinac 2100C nominal energies 6MeV and 9MeV (R p 3.00cm and 4.34cm respectively) were used for the tungsten eye shield measurements. For the photon measurements circular applicators of 3cm, 4cm and 5cm diameter were used and for the electrons standard 6x6cm and 10x 10cm applicators were used, with no custom inserts. A Scanditronix RFA-300 water phantom and Scanditronix RFAplus version 5.3 software application were used to collect and collate all data. The eye shields were the Radiation Products Design Inc. medium lead eye shield (item 934-014) and the MED-TEC tungsten eye shields MT-T-45 M and MT-T-45 S. It is demonstrated that electron fields have appreciably greater scatter into the area directly under the eye shields than the photon fields. Similarly at the region of d max for the electron fields the relative dose is appreciably greater than the photon fields at similar depth. The relative merits for

  12. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  13. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Science.gov (United States)

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  14. Eye Carduino: A Car Control System using Eye Movements

    Science.gov (United States)

    Kumar, Arjun; Nagaraj, Disha; Louzardo, Joel; Hegde, Rajeshwari

    2011-12-01

    Modern automotive systems are rapidly becoming highly of transportation, but can be a web integrated media centre. This paper explains the implementation of a vehicle control defined and characterized by embedded electronics and software. With new technologies, the vehicle industry is facing new opportunities and also new challenges. Electronics have improved the performance of vehicles and at the same time, new more complex applications are introduced. Examples of high level applications include adaptive cruise control and electronic stability programs (ESP). Further, a modern vehicle does not have to be merely a means using only eye movements. The EyeWriter's native hardware and software work to return the co-ordinates of where the user is looking. These co-ordinates are then used to control the car. A centre-point is defined on the screen. The higher on the screen the user's gaze is, the faster the car will accelerate. Braking is done by looking below centre. Steering is done by looking left and right on the screen.

  15. Dynamic modeling of patient and physician eye gaze to understand the effects of electronic health records on doctor-patient communication and attention.

    Science.gov (United States)

    Montague, Enid; Asan, Onur

    2014-03-01

    The aim of this study was to examine eye gaze patterns between patients and physicians while electronic health records were used to support patient care. Eye gaze provides an indication of physician attention to patient, patient/physician interaction, and physician behaviors such as searching for information and documenting information. A field study was conducted where 100 patient visits were observed and video recorded in a primary care clinic. Videos were then coded for gaze behaviors where patients' and physicians' gaze at each other and artifacts such as electronic health records were coded using a pre-established objective coding scheme. Gaze data were then analyzed using lag sequential methods. Results showed that there are several eye gaze patterns significantly dependent to each other. All doctor-initiated gaze patterns were followed by patient gaze patterns. Some patient-initiated gaze patterns were also followed by doctor gaze patterns significantly unlike the findings in previous studies. Health information technology appears to contribute to some of the new significant patterns that have emerged. Differences were also found in gaze patterns related to technology that differ from patterns identified in studies with paper charts. Several sequences related to patient-doctor-technology were also significant. Electronic health records affect the patient-physician eye contact dynamic differently than paper charts. This study identified several patterns of patient-physician interaction with electronic health record systems. Consistent with previous studies, physician initiated gaze is an important driver of the interactions between patient and physician and patient and technology. Published by Elsevier Ireland Ltd.

  16. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  17. Treatment of Dry Eye Disease.

    Science.gov (United States)

    Marshall, Leisa L; Roach, J Michael

    2016-02-01

    Review of the etiology, clinical manifestations, and treatment of dry eye disease (DED). Articles indexed in PubMed (National Library of Medicine), Iowa Drug Information Service (IDIS), and the Cochrane Reviews and Trials in the last 10 years using the key words "dry eye disease," "dry eye syndrome," "dry eye and treatment." Primary sources were used to locate additional resources. Sixty-eight publications were reviewed, and criteria supporting the primary objective were used to identify useful resources. The literature included practice guidelines, book chapters, review articles, original research articles, and product prescribing information for the etiology, clinical manifestations, diagnosis, and treatment of DED. DED is one of the most common ophthalmic disorders. Signs and symptoms of DED vary by patient, but may include ocular irritation, redness, itching, photosensitivity, visual blurring, mucous discharge, and decreased tear meniscus or break-up time. Symptoms improve with treatment, but the condition is not completely curable. Treatment includes reducing environmental causes, discontinuing medications that cause or worsen dry eye, and managing contributing ocular or systemic conditions. Most patients use nonprescription tear substitutes, and if these are not sufficient, other treatment is prescribed. These treatments include the ophthalmic anti-inflammatory agent cyclosporine, punctal occlusion, eye side shields, systemic cholinergic agents, and autologous serum tears. This article reviews the etiology, symptoms, and current therapy for DED.

  18. Analysis of Eye Care Services in Yemen

    OpenAIRE

    Saleh A. Al-Akily; Mutahar Y. Al-Shaer; Mahfouth A. Bamashmus; Abdulmoghni O. Al-Barrag; Tawfik K. Alkhatib; Hisham A. Al-Akhlee

    2017-01-01

    Purpose: The objective of this study was to undertake an analysis of the eye care services situation in Yemen and to assess ophthalmic human resources, eye units’ ownership and ophthalmic equipments. Methods: Eye care providers were surveyed by a standardized questionnaire which was sent to the 184 eye units in governmental, university, military, private and charity clinics and hospitals in Yemen and covered the period between 01 January to 31 December 2012. The questionnaire determined l...

  19. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020

    Science.gov (United States)

    2014-01-01

    Background Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Methods Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and ‘mid-level refractionists’ and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. Results HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed

  20. Mapping human resources for eye health in 21 countries of sub-Saharan Africa: current progress towards VISION 2020.

    Science.gov (United States)

    Palmer, Jennifer J; Chinanayi, Farai; Gilbert, Alice; Pillay, Devan; Fox, Samantha; Jaggernath, Jyoti; Naidoo, Kovin; Graham, Ronnie; Patel, Daksha; Blanchet, Karl

    2014-08-15

    Development of human resources for eye health (HReH) is a major focus of the Global Action Plan 2014 to 2019 to reduce the prevalence of avoidable visual impairment by 25% by the year 2019. The eye health workforce is thought to be much smaller in sub-Saharan Africa than in other regions of the world but data to support this for policy-making is scarce. We collected HReH and cataract surgeries data from 21 countries in sub-Sahara to estimate progress towards key suggested population-based VISION 2020 HReH indicators and cataract surgery rates (CSR) in 2011. Routinely collected data on practitioner and surgery numbers in 2011 was requested from national eye care coordinators via electronic questionnaires. Telephone and e-mail discussions were used to determine data collection strategies that fit the national context and to verify reported data quality. Information was collected on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and 'mid-level refractionists' and combined with publicly available population data to calculate practitioner to population ratios and CSRs. Associations with development characteristics were conducted using Wilcoxon rank sum tests and Spearman rank correlations. HReH data was not easily available. A minority of countries had achieved the suggested VISION 2020 targets in 2011; five countries for ophthalmologists/cataract surgeons, four for ophthalmic nurses/clinical officers and two for CSR. All countries were below target for optometrists, even when other cadres who perform refractions as a primary duty were considered. The regional (sample) ratio for surgeons (ophthalmologists and cataract surgeons) was 2.9 per million population, 5.5 for ophthalmic clinical officers and nurses, 3.7 for optometrists and other refractionists, and 515 for CSR. A positive correlation between GDP and CSR as well as many practitioner ratios was observed (CSR P = 0

  1. 30 CFR 57.15004 - Eye protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection. 57.15004 Section 57.15004... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personal Protection Surface and Underground § 57.15004 Eye protection. All persons shall wear safety glasses, goggles, or face...

  2. Using Peace Corps volunteers in community eye health

    OpenAIRE

    Barnes, Shawn

    2009-01-01

    Initiating a community eye health programme in an unfamiliar culture and language can be a daunting task. This report focuses on an underutilised resource for community eye health: American Peace Corps volunteers.

  3. 30 CFR 56.15004 - Eye protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection. 56.15004 Section 56.15004... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personal Protection § 56.15004 Eye protection. All persons shall wear safety glasses, goggles, or face shields or other suitable...

  4. Advocacy for eye care

    Directory of Open Access Journals (Sweden)

    Thulasiraj D Ravilla

    2012-01-01

    Full Text Available The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services - such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support - either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy.

  5. Film dosimetric investigations on the exposure of the eyes in radiation therapy of the head and the cervical region with fast electrons up to 17 MeV

    International Nuclear Information System (INIS)

    Stecher, M.; Eichler, R.

    1978-01-01

    Dose distributions in irradiating tumors of the head and the cervical region with 17 MeV electrons were determined in a phantom with films. From the isodoses obtained it can be derived how radiation reaches the eyes and how the dose to the eyes is influenced. Guidance is provided for the reduction of the dose to the eye. (author)

  6. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Directory of Open Access Journals (Sweden)

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  7. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  8. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  9. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  10. A survey of the use of electronic scientific information resources among medical and dental students

    Directory of Open Access Journals (Sweden)

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  11. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  12. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  13. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  14. Eye tracking in user experience design

    CERN Document Server

    Romano Bergstorm, Jennifer

    2014-01-01

    Eye Tracking for User Experience Design explores the many applications of eye tracking to better understand how users view and interact with technology. Ten leading experts in eye tracking discuss how they have taken advantage of this new technology to understand, design, and evaluate user experience. Real-world stories are included from these experts who have used eye tracking during the design and development of products ranging from information websites to immersive games. They also explore recent advances in the technology which tracks how users interact with mobile devices, large-screen displays and video game consoles. Methods for combining eye tracking with other research techniques for a more holistic understanding of the user experience are discussed. This is an invaluable resource to those who want to learn how eye tracking can be used to better understand and design for their users. * Includes highly relevant examples and information for those who perform user research and design interactive experi...

  15. 1st Workshop on Eye Tracking and Visualization

    CERN Document Server

    Chuang, Lewis; Fisher, Brian; Schmidt, Albrecht; Weiskopf, Daniel

    2017-01-01

    This book discusses research, methods, and recent developments in the interdisciplinary field that spans research in visualization, eye tracking, human-computer interaction, and psychology. It presents extended versions of papers from the First Workshop on Eye Tracking and Visualization (ETVIS), which was organized as a workshop of the IEEE VIS Conference 2015. Topics include visualization and visual analytics of eye-tracking data, metrics and cognitive models, eye-tracking experiments in the context of visualization interfaces, and eye tracking in 3D and immersive environments. The extended ETVIS papers are complemented by a chapter offering an overview of visualization approaches for analyzing eye-tracking data and a chapter that discusses electrooculography (EOG) as an alternative of acquiring information about eye movements. Covering scientific visualization, information visualization, and visual analytics, this book is a valuable resource for eye-tracking researchers within the visualization community.

  16. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  17. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  18. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    African Journals Online (AJOL)

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  19. Anterior eye protection with orbital neoplasia

    International Nuclear Information System (INIS)

    Hancock, S.L.

    1986-01-01

    The administration of adequate doses of radiation to tumors involving the orbit and surrounding facial structures and sinuses is often complicated by the need to protect the sensitive ocular components, the lens and cornea. A technique has been devised that uses four photon beam fields and an optional electron field to treat the contents of both orbits and adjacent sinuses with effective, reproducible protection of cornea and lens. Essential features include: alignment of the corneal surfaces with the central plane of rotation of the treatment machine, use of a narrow eye block across the entire beam to shield a strip equal to the width of the cornea, positioned symmetrically across the central plane of rotation, fine alignment of the eye block with both corneal surfaces by altering pedestal angle, treatment with paired, wedged, anterior oblique fields to encompass desired orbital and sinus volumes with additional blocking placed as needed, and complementary, lateral strip fields using collimators set to eye block thickness to equalize dose in the posterior orbit shielded by the strip eye block. A similar anterior electron beam strip field may be added to boost the medial orbit and ethmoid regions covered by the eye block. Bite block head immobilization and easy, direct daily visualization of block position assures eye protection for each treatment and provides substantial reduction in dose to the cornea, lens and iris. Additional blocking may be incorporated to provide partial lacrimal and parotid sparing

  20. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  1. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  2. EYE CONTROLLED SWITCHING USING CIRCULAR HOUGH TRANSFORM

    OpenAIRE

    Sagar Lakhmani

    2014-01-01

    The paper presents hands free interface between electrical appliances or devices. This technology is intended to replace conventional switching devices for the use of disabled. It is a new way to interact with the electrical or electronic devices that we use in our daily life. The paper illustrates how the movement of eye cornea and blinking can be used for switching the devices. The basic Circle Detection algorithm is used to determine the position of eye. Eye blinking is used...

  3. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  4. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  5. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Jin Han, Tae; Kim, Haeyoung; Lee, Me-Yeon; Ju Kim, Kyoung, E-mail: kjkim@hallym.or.kr; Bae, Hoonsik

    2015-10-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

  6. Building the eye care team

    Directory of Open Access Journals (Sweden)

    Thulasiraj Ravilla

    2014-07-01

    Full Text Available Eye care services are people intensive. They require the right people (competence, in the right numbers (capacity, in the right mix (team with the right resources and processes (enabling conditions to ensure effective and sustainable delivery of patient care.

  7. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Science.gov (United States)

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  8. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  9. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    Science.gov (United States)

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.

  10. Translators’ Use of Digital Resources during Translation

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2017-01-01

    This paper presents the findings from a study on translators’ use of digital resources during the translation process. Eye tracking data and screen recording data from 18 professional translators are analysed in order to 1) examine how much time translators spend on digital resource consultation...... compared with translation drafting and translation revision, 2) examine how eye movements differ between translation drafting, revision and digital resource consultation and 3) investigate what types of digital resources are used by translators. The findings demonstrate that digital resource consultation...... constitutes a considerable amount of the translation process. The findings also show longer fixations and larger pupils during resource consultation, indicating heavier cognitive load, and finally the study identifies considerable variation in the use of resources between translators....

  11. Eye structure and vision in the freshwater pulmonate mollusc Planorbarius corneus

    NARCIS (Netherlands)

    Zhukov, VV; Bobkova, MB; Vakolyuk, IA

    2002-01-01

    The structure of the mollusc Planorbarius corneus eye was studied using light and electron microscopy. The eye consists of the cornea, eye lens of non-spherical shape, and the vitreous body tightly bound to it, as well as of a monolayer non-inverted retina composed of photoreceptor and supporting

  12. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  13. Eyes on the Road

    Centers for Disease Control (CDC) Podcasts

    One of the first lessons new drivers learn is to keep their eyes on the road. Unfortunately, cell phones and other electronic devices are causing many drivers to lose their focus, and sometimes their lives. In this podcast, Rebecca Naumann discusses the dangers of distracted driving.

  14. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms.

    Science.gov (United States)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Han, Tae Jin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Bae, Hoonsik

    2015-01-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  15. 30 CFR 56.15014 - Eye protection when operating grinding wheels.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection when operating grinding wheels... MINES Personal Protection § 56.15014 Eye protection when operating grinding wheels. Face shields or goggles in good condition shall be worn when operating a grinding wheel. [53 FR 32526, Aug. 25, 1988] ...

  16. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  17. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  18. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  19. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    OpenAIRE

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  20. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Science.gov (United States)

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  1. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Science.gov (United States)

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  2. 21 CFR 886.4400 - Electronic metal locator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic foreign bodies in the eye or eye socket. (b) Classification. Class II. ...

  3. Display device combining ambient light with magnified virtual images generated in the eye path of the observer

    NARCIS (Netherlands)

    2005-01-01

    A display device positions an observer's eye (or eyes) to look in a particular direction (eye path). An electronically controlled image generating element in the eye path generates artificial images which are magnified to create a virtual image for the eye. The image generating element is

  4. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  5. 30 CFR 57.15014 - Eye protection when operating grinding wheels.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection when operating grinding wheels. 57.15014 Section 57.15014 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... grinding wheels. Face shields or goggles in good condition shall be worn when operating a grinding wheel...

  6. CUE: counterfeit-resistant usable eye movement-based authentication via oculomotor plant characteristics and complex eye movement patterns

    Science.gov (United States)

    Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.

    2012-06-01

    The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.

  7. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Science.gov (United States)

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  8. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Science.gov (United States)

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  9. Allocation of Cognitive Resources in Translation

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    The present study is an empirical investigation of translators' allocation of cognitive resources during the translation process, and it aims at investigating how translators' mental processing resources are put to use during translation. The study bases ts analyses on quantitative eye...

  10. Professional management for eye care

    Directory of Open Access Journals (Sweden)

    AK Sivakumar

    2006-09-01

    Full Text Available IntroductionThe global initiative VISION 2020: The Right to Sight, estimates that only 25 per cent of existing infrastructure is used for eye care, while the target utilisation is set at 90 per cent. This requires a complete reorganisation. Many providers have the potential to significantly enhance their service by adopting professional management practice and new technologies in clinical services. This article addresses this opportunity from a professional management perspective.The responsibilities of a hospital administrator could be broadly classified as managing patient care, functional areas, support services, and developmental work. Eye care providers need to focus on four key areas. Strategic management to enhance the efficiency of their organisations requires: human resources management; quality management; marketing; and financial sustainability.

  11. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  12. SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [University of Washington Medical Center, Seattle, WA (United States); Wootton, L [University of Washington School of Medicine, Seattle, WA (United States); Gopan, O; Liao, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

  13. Eye movements in patients with Whiplash Associated Disorders: A systematic review

    OpenAIRE

    Ischebeck, B.; Vries, Jurryt; Geest, Jos; Janssen, Malou; Wingerden, Jan-Paul; Kleinrensink, Gert Jan; Frens, Maarten

    2016-01-01

    textabstractBackground: Many people with Whiplash Associated Disorders (WAD) report problems with vision, some of which may be due to impaired eye movements. Better understanding of such impaired eye movements could improve diagnostics and treatment strategies. This systematic review surveys the current evidence on changes in eye movements of patients with WAD and explains how the oculomotor system is tested. Methods: Nine electronic data bases were searched for relevant articles from incepti...

  14. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  15. Speed matters : relationship between speed of eye movements and modification of aversive autobiographical memories

    NARCIS (Netherlands)

    van Veen, Suzanne; van Schie, Kevin; Wijngaards, Leoniek; Littel, Marianne; Engelhard, Iris; van den Hout, Marcel

    2015-01-01

    Eye movement desensitization and reprocessing (EMDR) is an efficacious treatment for post-traumatic stress disorder. In EMDR, patients recall a distressing memory and simultaneously make eye movements (EM). Both tasks are considered to require limited working memory (WM) resources. Because this

  16. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  17. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  18. Implantable medical electronics prosthetics, drug delivery, and health monitoring

    CERN Document Server

    Khanna, Vinod Kumar

    2016-01-01

    This book is a comprehensive, interdisciplinary resource for the latest information on implantable medical devices, and is intended for graduate students studying electrical engineering, electronic instrumentation, and biomedical engineering. It is also appropriate for academic researchers, professional engineers, practicing doctors, and paramedical staff. Divided into two sections on Basic Concepts and Principles, and Applications, the first section provides an all-embracing perspective of the electronics background necessary for this work. The second section deals with pacing techniques used for the heart, brain, spinal cord, and the network of nerves that interlink the brain and spinal cord with the major organs, including ear and eye prostheses. The four main offshoots of implantable electronics, which this book discusses, are: The insertion of an implantable neural amplifier for accurate recording of neural signals for neuroengineering studies The use of implantable pulse generators for pacing the activi...

  19. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  20. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  1. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  2. Telocytes and stem cells in limbus and uvea of mouse eye.

    Science.gov (United States)

    Luesma, María José; Gherghiceanu, Mihaela; Popescu, Laurenţiu M

    2013-08-01

    The potential of stem cell (SC) therapies for eye diseases is well-recognized. However, the results remain only encouraging as little is known about the mechanisms responsible for eye renewal, regeneration and/or repair. Therefore, it is critical to gain knowledge about the specific tissue environment (niches) where the stem/progenitor cells reside in eye. A new type of interstitial cell-telocyte (TC) (www.telocytes.com) was recently identified by electron microscopy (EM). TCs have very long (tens of micrometres) and thin (below 200 nm) prolongations named telopodes (Tp) that form heterocellular networks in which SCs are embedded. We found TCs by EM and electron tomography in sclera, limbus and uvea of the mouse eye. Furthermore, EM showed that SCs were present in the anterior layer of the iris and limbus. Adhaerens and gap junctions were found to connect TCs within a network in uvea and sclera. Nanocontacts (electron-dense structures) were observed between TCs and other cells: SCs, melanocytes, nerve endings and macrophages. These intercellular 'feet' bridged the intercellular clefts (about 10 nm wide). Moreover, exosomes (extracellular vesicles with a diameter up to 100 nm) were delivered by TCs to other cells of the iris stroma. The ultrastructural nanocontacts of TCs with SCs and the TCs paracrine influence via exosomes in the epithelial and stromal SC niches suggest an important participation of TCs in eye regeneration. © 2013 The Authors. Journal of Cellular and Molecular Medicine Published by Foundation for Cellular and Molecular Medicine/Blackwell Publishing Ltd.

  3. Rapid assessment methods in eye care: An overview

    Directory of Open Access Journals (Sweden)

    Srinivas Marmamula

    2012-01-01

    Full Text Available Reliable information is required for the planning and management of eye care services. While classical research methods provide reliable estimates, they are prohibitively expensive and resource intensive. Rapid assessment (RA methods are indispensable tools in situations where data are needed quickly and where time- or cost-related factors prohibit the use of classical epidemiological surveys. These methods have been developed and field tested, and can be applied across almost the entire gamut of health care. The 1990s witnessed the emergence of RA methods in eye care for cataract, onchocerciasis, and trachoma and, more recently, the main causes of avoidable blindness and visual impairment. The important features of RA methods include the use of local resources, simplified sampling methodology, and a simple examination protocol/data collection method that can be performed by locally available personnel. The analysis is quick and easy to interpret. The entire process is inexpensive, so the survey may be repeated once every 5-10 years to assess the changing trends in disease burden. RA survey methods are typically linked with an intervention. This article provides an overview of the RA methods commonly used in eye care, and emphasizes the selection of appropriate methods based on the local need and context.

  4. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Science.gov (United States)

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  5. Model of e-learning with electronic educational resources of new generation

    OpenAIRE

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  6. A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease

    Science.gov (United States)

    Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue

    2014-03-01

    A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural® Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application.

  7. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  8. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  9. A scalable and deformable stylized model of the adult human eye for radiation dose assessment.

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S R; Bolch, Wesley E

    2018-03-23

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from -12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of -12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the eye crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes. © 2018

  10. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  11. Visual Data Mining: An Exploratory Approach to Analyzing Temporal Patterns of Eye Movements

    Science.gov (United States)

    Yu, Chen; Yurovsky, Daniel; Xu, Tian

    2012-01-01

    Infant eye movements are an important behavioral resource to understand early human development and learning. But the complexity and amount of gaze data recorded from state-of-the-art eye-tracking systems also pose a challenge: how does one make sense of such dense data? Toward this goal, this article describes an interactive approach based on…

  12. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  13. A scalable and deformable stylized model of the adult human eye for radiation dose assessment

    Science.gov (United States)

    El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.

    2018-05-01

    With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from  ‑12 to  +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of  ‑12D and  +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non

  14. Patterning of a compound eye on an extinct dipteran wing

    OpenAIRE

    Dinwiddie, April; Rachootin, Stan

    2010-01-01

    We have discovered unexpected similarities between a novel and characteristic wing organ in an extinct biting midge from Baltic amber, Eohelea petrunkevitchi, and the surface of a dipteran's compound eye. Scanning electron microscope images now reveal vestigial mechanoreceptors between the facets of the organ. We interpret Eohelea's wing organ as the blending of these two developmental systems: the formation and patterning of the cuticle in the eye and of the wing.

  15. Measurement of eye aberrations in a speckle field

    International Nuclear Information System (INIS)

    Larichev, A V; Ivanov, P V; Iroshnikov, N G; Shmalgauzen, V I

    2001-01-01

    The influence of speckles on the performance of a Shark-Hartmann wavefront sensor is investigated in the eye aberration studies. The dependence of the phase distortion measurement error on the characteristic speckle size is determined experimentally. Scanning of the reference source was used to suppress the speckle structure of the laser beam scattered by the retina. The technique developed by us made it possible to study the time dependence of the human eye aberrations with a resolution of 30 ms. (laser applications and other topics in quantum electronics)

  16. A new mapping function in table-mounted eye tracker

    Science.gov (United States)

    Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng

    2018-01-01

    Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.

  17. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  18. The evolution of vertebrate eye size across an environmental gradient: phenotype does not predict genotype in a Trinidadian killifish.

    Science.gov (United States)

    Beston, Shannon M; Wostl, Elijah; Walsh, Matthew R

    2017-08-01

    Vertebrates exhibit substantial variation in eye size. Eye size correlates positively with visual capacity and behaviors that enhance fitness, such as predator avoidance. This foreshadows a connection between predation and eye size evolution. Yet, the conditions that favor evolutionary shifts in eye size, besides the well-known role for light availability, are unclear. We tested the influence of predation on the evolution of eye size in Trinidadian killifish, Rivulus hartii. Rivulus are located across a series of communities where they coexist with visually oriented piscivores ("high predation" sites), and no predators ("Rivulus-only" sites). Wild-caught Rivulus from high predation sites generally exhibited a smaller relative eye size than communities that lack predators. Yet, such differences were inconsistent across rivers. Second-generation common garden reared fish revealed repeatable decreases in eye size in Rivulus from high predation sites. We performed additional experiments that tested the importance of light and resources on eye size evolution. Sites that differ in light or resource availability did not differ in eye size. Our results argue that differences in predator-induced mortality underlie genetically-based shifts in vertebrate eye size. We discuss the drivers of eye size evolution in light of the nonparallel trends between the phenotypic and common garden results. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  19. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  20. A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease

    International Nuclear Information System (INIS)

    Zhang, Wenjian; Liu, Chang; Wei, Gang; Lu, Weiyue; Wang, Yan; Lee, Benjamin Tak Kwong

    2014-01-01

    A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural ®  Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application. (paper)

  1. Neurons in the monkey amygdala detect eye-contact during naturalistic social interactions

    Science.gov (United States)

    Mosher, Clayton P.; Zimmerman, Prisca E.; Gothard, Katalin M.

    2014-01-01

    Summary Primates explore the visual world through eye-movement sequences. Saccades bring details of interest into the fovea while fixations stabilize the image [1]. During natural vision, social primates direct their gaze at the eyes of others to communicate their own emotions and intentions and to gather information about the mental states of others [2]. Direct gaze is an integral part of facial expressions that signals cooperation or conflict over resources and social status [3-6]. Despite the great importance of making and breaking eye contact in the behavioral repertoire of primates, little is known about the neural substrates that support these behaviors. Here we show that the monkey amygdala contains neurons that respond selectively to fixations at the eyes of others and to eye contact. These “eye cells” share several features with the canonical, visually responsive neurons in the monkey amygdala, however, they respond to the eyes only when they fall within the fovea of the viewer, either as a result of a deliberate saccade, or as eyes move into the fovea of the viewer during a fixation intended to explore a different feature. The presence of eyes in peripheral vision fails to activate the eye cells. These findings link the primate amygdala to eye-movements involved in the exploration and selection of details in visual scenes that contain socially and emotionally salient features. PMID:25283782

  2. Neurons in the monkey amygdala detect eye contact during naturalistic social interactions.

    Science.gov (United States)

    Mosher, Clayton P; Zimmerman, Prisca E; Gothard, Katalin M

    2014-10-20

    Primates explore the visual world through eye-movement sequences. Saccades bring details of interest into the fovea, while fixations stabilize the image. During natural vision, social primates direct their gaze at the eyes of others to communicate their own emotions and intentions and to gather information about the mental states of others. Direct gaze is an integral part of facial expressions that signals cooperation or conflict over resources and social status. Despite the great importance of making and breaking eye contact in the behavioral repertoire of primates, little is known about the neural substrates that support these behaviors. Here we show that the monkey amygdala contains neurons that respond selectively to fixations on the eyes of others and to eye contact. These "eye cells" share several features with the canonical, visually responsive neurons in the monkey amygdala; however, they respond to the eyes only when they fall within the fovea of the viewer, either as a result of a deliberate saccade or as eyes move into the fovea of the viewer during a fixation intended to explore a different feature. The presence of eyes in peripheral vision fails to activate the eye cells. These findings link the primate amygdala to eye movements involved in the exploration and selection of details in visual scenes that contain socially and emotionally salient features. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Directory of Open Access Journals (Sweden)

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  4. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  5. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  6. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  7. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.

    Science.gov (United States)

    Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E

    2016-11-01

    To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.

  9. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Science.gov (United States)

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  10. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  12. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  13. The Barrie Jones Lecture-Eye care for the neglected population: challenges and solutions.

    Science.gov (United States)

    Rao, G N

    2015-01-01

    Globally, pockets of 'neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of 'Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people.

  14. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  15. Dose conversion coefficients for photon exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  16. Dose conversion coefficients for photon exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H p (3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  17. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  18. The eye of the African mole-rat Cryptomys anselli : to see or not to see?

    NARCIS (Netherlands)

    Cernuda-Cernuda, R; Garcia-Fernandez, JM; Gordijn, MCM; Bovee-Geurts, PHM; DeGrip, WJ; de Grip, W.J.

    In an attempt to clarify its possible physiological role, we studied the eye of the Zambian mole rat Cryptomys anselli by light, electron and confocal microscopy using conventional staining as well as immunolabelling with rod and cone cell markers. The small eyes of Cryptomys are located

  19. The eye of the african mole-rat Cryptomys anselli: to see or not to see?

    NARCIS (Netherlands)

    Cernuda-Cernuda, R.; Garcia-Fernandez, J.M.; Gordijn, M.C.; Bovee-Geurts, P.H.M.; Grip, W.J. de

    2003-01-01

    In an attempt to clarify its possible physiological role, we studied the eye of the Zambian mole rat Cryptomys anselli by light, electron and confocal microscopy using conventional staining as well as immunolabelling with rod and cone cell markers. The small eyes of Cryptomys are located

  20. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  1. The Barrie Jones Lecture—Eye care for the neglected population: challenges and solutions

    Science.gov (United States)

    Rao, G N

    2015-01-01

    Globally, pockets of ‘neglected populations' do not have access to basic health-care services and carry a much greater risk of blindness and visual impairment. While large-scale public health approaches to control blindness due to vitamin A deficiency, onchocerciasis, and trachoma are successful, other causes of blindness still take a heavy toll in the population. High-quality comprehensive eye care that is equitable is the approach that needs wide-scale application to alleviate this inequity. L V Prasad Eye Institute of India developed a multi-tier pyramidal model of eye care delivery that encompasses all levels from primary to advanced tertiary (quaternary). This has demonstrated the feasibility of ‘Universal Eye Health Coverage' covering promotive, preventive, corrective, and rehabilitative aspects of eye care. Using human resources with competency-based training, effective and cost-effective care could be provided to many disadvantaged people. PMID:25567375

  2. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  5. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  6. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    Science.gov (United States)

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  7. The State of Paediatric Eye Care in Nigeria: A Situational Review ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    children in resource poor countries is one of the ... infant mortality rate (currently 100 deaths /1000. 3, 4 live births . A child .... reason for the gross inadequacy in the delivery of safe eye care in the .... distribution of public information materials.

  8. Ossification Vesicles with Calcium Phosphate in the Eyes of the Insect Copium teucrii (Hemiptera: Tingidae

    Directory of Open Access Journals (Sweden)

    Javier Garcia-Guinea

    2011-01-01

    Full Text Available Arthropod eyes are built of repeating units named ommatidia. Each single ommatidium unit contains a cluster of photoreceptor cells surrounded by support cells and pigment cells. The insect Copium eye ommatidia include additional calcium-phosphate deposits, not described in insects to date, which can be examined today using a combined set of modern microscopy and spectroscopy techniques. Teucrium gnaphalodes L'Her plants, growing in central Spain, develop galls induced by Copium insects. A survey of C. teucrii adult specimens resulted in surprising environmental scanning electron microscopy (ESEM images, showing that their bright red eyes contain a calcium-phosphate mineralization. A complete survey of Copium eye specimens was performed by ESEM using energy-dispersive spectroscopy, backscattered electron detector and cathodoluminescence (CL probes, field emission scanning electron microscopy, micro-Raman spectroscopy, and confocal laser scanning microscopy in order to learn ommatidia features, such as chemical composition, molecular structure, cell membrane, and internal ommatidium eye fluids and calcium-phosphate distribution deposits. The CL panchromatic images distinguish between the calcium-phosphate ommatidium and calcium-phosphate setae, which are more apatite rich. They show Raman bands attributable to bone tissue apatite biomaterials, such as bone, collagen, lipids, and blood, i.e., peptides, amide-S, amide-II, amide-III, and cytochrome P-450scc. The chemical composition of both galls and leaves of T. gnaphalodes was determined by gas chromatography – mass spectrometry (GC-MS of their extracts. The spectrometric and microscopic images reveal that the calcium-phosphate mineralization is formed and constrained to Copium ommatidia, which are both matrix vesicles generating mixtures of apatite collagen and operational compound eyes of the insect.

  9. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  10. A teaching resource using the GUIDE environment: simplified model of the eye for secondary school students

    Science.gov (United States)

    Gómez-Varela, A. I.; Salvado-Vara, F.; Bao-Varela, C.

    2014-07-01

    Nowadays, new technologies have great influence on our lives and how we access to the information. The new generations have never known a world without them and make use of these new technologies in practically all facets of their day-to-day. Education systems have also evolved rapidly and frequently make use of learning strategies based on interactive tools. In this work we have created a graphical user interface with GUIDE, a development environment of MATLAB, to show, in a simple way, how the eye works. This interactive program is addressed to the first courses of secondary education and designed to introduce them to the basic concepts of the normal refractive condition of the eye and the most common refractive errors, as myopia and hyperopia. The graphic interface makes use of the simplified model of the eye, where the optic system of the visual organ is represented by a converging lens (cornea and crystalline) and a screen (retina). Emmetropic, myopic and hyperopic eye operation is shown graphically to the students, as well as how these focusing errors can be solved with a diverging and converging lens, respectively. This teaching tool was used this academic course in the Colegio Hogar de Santa Margarita (A Coruña) for a better understanding of the students in this matter and to catch their attention to the world of Optics and its importance.

  11. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Directory of Open Access Journals (Sweden)

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  12. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  13. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    International Nuclear Information System (INIS)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  14. Two-Laser Interference Visible to the Naked Eye

    Science.gov (United States)

    Kawalec, Tomasz; Bartoszek-Bober, Dobroslawa

    2012-01-01

    An experimental setup allowing the observation of two-laser interference by the naked eye is described. The key concept is the use of an electronic phase lock between two external cavity diode lasers. The experiment is suitable both for undergraduate and graduate students, mainly in atomic physics laboratories. It gives an opportunity for…

  15. Public Awareness regarding Common Eye Diseases among Saudi Adults in Riyadh City: A Quantitative Study

    Directory of Open Access Journals (Sweden)

    Waleed A. Al Rashed

    2017-01-01

    Full Text Available Aim. The current study aimed to evaluate the knowledge of eye disease and awareness of eye care among the Saudi adults and to explore existing eye-related misconceptions in the community. Methods. A cross-sectional study was conducted in Riyadh city during May and June 2016. A self-administered anonymous online questionnaire was used to explore the most common misconceptions related to eye diseases and eye care. Results. Out of 1000 individuals, only 711 (71.1% participant responses were received. The participants’ acceptable knowledge (score ≥50% was high about the eye problem in diabetes (88.6%, ocular trauma (81.2%, and other general eye diseases (91.3%, whereas low about refractive errors (63%, pediatric eye problems (51.5%, and glaucoma (14.8%. The variation in knowledge about specific ocular morbidities was significant (p<0.001. The majority of participants reported sources of information about the common eye diseases and eye care encountered from the community, internet-based resources, and social media. Conclusions. The majority of the participants had awareness about the common eye diseases, whereas low percentage of participant’s awareness about specific condition of eye diseases. Public eye health awareness should be more focused on social media and the internet to be able to cover the younger individuals of the community.

  16. Eye tracking and climate change: How is climate literacy information processed?

    Science.gov (United States)

    Williams, C. C.; McNeal, K. S.

    2011-12-01

    The population of the Southeastern United States is perceived to be resistant to information regarding global climate change. The Climate Literacy Partnership in the Southeast (CLiPSE) project was formed to provide a resource for climate science information. As part of this project, we are evaluating the way that education materials influence the interpretation of climate change related information. At Mississippi State University, a study is being conducted examining how individuals from the Southeastern United States process climate change information and whether or not the interaction with such information impacts the interpretation of subsequent climate change related information. By observing the patterns both before and after an educational intervention, we are able to evaluate the effectiveness of the climate change information on an individual's interpretation of related information. Participants in this study view figures describing various types of climate change related information (CO2 emissions, sea levels, etc.) while their eye movements are tracked to determine a baseline for the way that they process this type of graphical data. Specifically, we are examining time spent viewing and number of fixations on critical portions of the figures prior to exposure to an educational document on climate change. Following the baseline period, we provide participants with portions of a computerized version of Climate Literacy: The Essential Principles of Climate Sciences that the participants read at their own pace while their eye movements are monitored. Participants are told that they will be given a test on the material after reading the resource. After reading the excerpt, participants are presented with a new set of climate change related figures to interpret (with eye tracking) along with a series of questions regarding information contained in the resource. We plan to evaluate changes that occur in the way that climate change related information is

  17. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Directory of Open Access Journals (Sweden)

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  18. Aerosol container-related eye injuries in the United States: 1997-2009.

    Science.gov (United States)

    Seidman, Carly J; Linakis, James G; Mello, Michael J; Greenberg, Paul B

    2011-06-01

    To quantify and characterize eye injuries related to aerosol container consumer products treated in United States hospital emergency departments (EDs) from 1997 through 2009. Retrospective study. Descriptive analysis of aerosol container-related eye injury data derived from the National Electronic Injury Surveillance System, a stratified probability sample of hospital-affiliated United States EDs. Data collected included demographic variables (gender and age), locale, diagnoses, and hospital disposition associated with aerosol container-related eye injuries treated in United States EDs from 1997 through 2009. Products associated with injury and mechanisms of injury also were extracted and analyzed. There were an estimated 10 765 (95% confidence interval [CI], 9842 to 11 688) visits to United States EDs for aerosol container-related eye injuries during the study period; 6756 (95% CI, 5771 to 7742; 63%) patients were male; 5927 (95% CI, 4956 to 6897; 55%) injuries occurred in children (age container-related eye injuries in the United States occur in men and children and that self-inflicted spray to the eye is the most common mechanism of injury. Further research is needed to devise effective prevention strategies for these types of injuries. Published by Elsevier Inc.

  19. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  20. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  1. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  2. Lens subluxation after plasmin and SF6 injections in rabbit eyes.

    Directory of Open Access Journals (Sweden)

    Wei-Chi Wu

    Full Text Available To investigate the rate of lens subluxation following plasmin and/or SF6 injections in eyes, and whether a subsequent elevated level of vascular endothelial growth factor (VEGF and vitreous tap would aggravate subluxation.Four groups of rabbits were used. Group 1 received an intravitreal injection (IVI of plasmin and SF6 in the right eye; group 2 received an IVI of plasmin in the right eye; group 3 received an IVI of SF6 in the right eye; and group 4 received an IVI of balanced salt solution in the right eye. After treatment, IVIs of VEGF were given and vitreous tap was performed three times, followed by clinical observation of lens subluxation and scanning electronic microscope evaluation of the zonular fibers.After IVIs of plasmin and SF6, and VEGF and vitreous tap had been performed one to three times, lens subluxation was noted in 0%, 43%, 71%, 71%, and 86% of the eyes in group 1. After IVIs of plasmin, VEGF, and vitreous tap had been performed one to three times, lens subluxation was noted in 11%, 22%, 44%, 44%, and 67% of the eyes in group 2. The eyes in group 3 and 4 did not show signs of lens subluxation after VEGF IVIs and vitreous tap. Histology confirmed zonular fiber damage in the eyes treated with plasmin.The incidence of lens subluxation increased following plasmin injections in the eyes, and this was aggravated by the subsequent high VEGF level in the eyes and vitreous tapping. Zonular fibers were disrupted following plasmin treatment. These effects should be kept in mind when using plasmin enzymes in patients with vitreoretinal abnormalities.

  3. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  4. Using Reading Times and Eye-Movements to Measure Cognitive Engagement

    Science.gov (United States)

    Miller, Brian W.

    2015-01-01

    Self-paced reading and eye-tracking can be used to measure microlevel student engagement during science instruction. These methods imply a definition of engagement as the quantity and quality of mental resources directed at an object and the emotions and behaviors entailed. This definition is theoretically supported by models of reading…

  5. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  7. Punctal occlusion for dry eye syndrome.

    Science.gov (United States)

    Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D

    2017-06-26

    Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We

  8. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  10. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  11. Integrated model of primary and secondary eye care for underserved rural areas: The L V Prasad Eye Institute experience

    Directory of Open Access Journals (Sweden)

    Gullapalli N Rao

    2012-01-01

    Full Text Available Blindness is a major global public health problem and recent estimates from World Health Organization (WHO showed that in India there were 62 million visually impaired, of whom 8 million are blind. The Andhra Pradesh Eye Disease Study (APEDS provided a comprehensive estimate for prevalence and causes of blindness for the state of Andhra Pradesh (AP. It also highlighted that uptake of services was also an issue, predominantly among lower socio-economic groups, women, and rural populations. On the basis of this analysis, L V Prasad Eye Institute (LVPEI developed a pyramidal model of eye care delivery. This article describes the LVPEI eye care delivery model. The article discusses infrastructure development, human resource development, and service delivery (including prevention and promotion in the context of primary and secondary care service delivery in rural areas. The article also alludes to opportunities for research at these levels of service delivery and the amenability of the evidence generated at these levels of the LVPEI eye health pyramid for advocacy and policy planning. In addition, management issues related to the sustainability of service delivery in rural areas are discussed. The article highlights the key factors required for the success of the LVPEI rural service delivery model and discusses challenges that need to be overcome to replicate the model. The article concludes by noting the potential to convert these challenges into opportunities by integrating certain aspects of the existing healthcare system into the model. Examples include screening of diabetes and diabetic retinopathy in order to promote higher community participation. The results of such integration can serve as evidence for advocacy and policy.

  12. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    Science.gov (United States)

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  13. EyeFrame: Real-time memory aid improves human multitasking via domain-general eye tracking procedures

    Directory of Open Access Journals (Sweden)

    P. eTaylor

    2015-09-01

    Full Text Available OBJECTIVE: We developed an extensively general closed-loop system to improve human interaction in various multitasking scenarios, with semi-autonomous agents, processes, and robots. BACKGROUND: Much technology is converging toward semi-independent processes with intermittent human supervision distributed over multiple computerized agents. Human operators multitask notoriously poorly, in part due to cognitive load and limited working memory. To multitask optimally, users must remember task order, e.g., the most neglected task, since longer times not monitoring an element indicates greater probability of need for user input. The secondary task of monitoring attention history over multiple spatial tasks requires similar cognitive resources as primary tasks themselves. Humans can not reliably make more than ~2 decisions/s. METHODS: Participants managed a range of 4-10 semi-autonomous agents performing rescue tasks. To optimize monitoring and controlling multiple agents, we created an automated short term memory aid, providing visual cues from users' gaze history. Cues indicated when and where to look next, and were derived from an inverse of eye fixation recency. RESULTS: Contingent eye tracking algorithms drastically improved operator performance, increasing multitasking capacity. The gaze aid reduced biases, and reduced cognitive load, measured by smaller pupil dilation. CONCLUSIONS: Our eye aid likely helped by delegating short-term memory to the computer, and by reducing decision making load. Past studies used eye position for gaze-aware control and interactive updating of displays in application-specific scenarios, but ours is the first to successfully implement domain-general algorithms. Procedures should generalize well to: process control, factory operations, robot control, surveillance, aviation, air traffic control, driving, military, mobile search and rescue, and many tasks where probability of utility is predicted by duration since last

  14. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  15. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  16. Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop

    Directory of Open Access Journals (Sweden)

    Hyeong-sik Seo

    2008-06-01

    Full Text Available Objective : This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods : The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results : 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn’t physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn’t eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions : I suggested that Bovis Calculus pharmacopuncture solution didn’t induced eye irritation in rabbits.

  17. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  18. The role of eye protection in work-related eye injuries.

    Science.gov (United States)

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  20. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  2. Library resources on the Internet

    Science.gov (United States)

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  3. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  4. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  5. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  6. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    Science.gov (United States)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  7. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    Science.gov (United States)

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  9. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  10. Selection and Evaluation of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  11. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  12. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  13. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  14. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Directory of Open Access Journals (Sweden)

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  15. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Science.gov (United States)

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  16. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  17. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  18. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  19. Eye absence does not regulate planarian stem cells during eye regeneration

    OpenAIRE

    LoCascio, Samuel A.; Lapan, Sylvain W.; Reddien, Peter W.

    2017-01-01

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, ...

  20. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  1. Trends and implications for achieving VISION 2020 human resources for eye health targets in 16 countries of sub-Saharan Africa by the year 2020.

    Science.gov (United States)

    Palmer, Jennifer J; Chinanayi, Farai; Gilbert, Alice; Pillay, Devan; Fox, Samantha; Jaggernath, Jyoti; Naidoo, Kovin; Graham, Ronnie; Patel, Daksha; Blanchet, Karl

    2014-08-15

    Development of human resources for eye health (HReH) is a major global eye health strategy to reduce the prevalence of avoidable visual impairment by the year 2020. Building on our previous analysis of current progress towards key HReH indicators and cataract surgery rates (CSRs), we predicted future indicator achievement among 16 countries of sub-Saharan Africa by 2020. Surgical and HReH data were collected from national eye care programme coordinators on six practitioner cadres: ophthalmologists, cataract surgeons, ophthalmic clinical officers, ophthalmic nurses, optometrists and 'mid-level refractionists' and combined them with publicly available population data to calculate practitioner-to-population ratios and CSRs. Data on workforce entry and exit (2008 to 2010) was used to project practitioner population and CSR growth between 2011 and 2020 in relation to projected growth in the general population. Associations between indicator progress and the presence of a non-physician cataract surgeon cadre were also explored using Wilcoxon rank sum tests and Spearman rank correlations. In our 16-country sample, practitioner per million population ratios are predicted to increase slightly for surgeons (ophthalmologists/cataract surgeons, from 3.1 in 2011 to 3.4 in 2020) and ophthalmic nurses/clinical officers (5.8 to 6.8) but remain low for refractionists (including optometrists, at 3.6 in 2011 and 2020). Among countries that have not already achieved target indicators, however, practitioner growth will be insufficient for any additional countries to reach the surgeon and refractionist targets by year 2020. Without further strategy change and investment, even after 2020, surgeon growth is only expected to sufficiently outpace general population growth to reach the target in one country. For nurses, two additional countries will achieve the target while one will fall below it. In 2011, high surgeon practitioner ratios were associated with high CSR, regardless of the type

  2. Efficiency of optical-electronic systems: methods application for the analysis of structural changes in the process of eye grounds diagnosis

    Science.gov (United States)

    Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan

    2017-08-01

    Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.

  3. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  4. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  5. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  6. Perceptions of Eye Health and Eye Health Services among Adults Attending Outreach Eye Care Clinics in Papua New Guinea.

    Science.gov (United States)

    Burnett, Anthea; Yu, Mitasha; Paudel, Prakash; Naduvilath, Thomas; Fricke, Tim R; Hani, Yvonne; Garap, Jambi

    2015-01-01

    To determine how people attending outreach eye care clinics in Papua New Guinea (PNG) perceive eye health and eye health services. An interview-based questionnaire was administrated to a convenience sample of 614 adult participants across four provinces and perceptions of eye health and eye health services were recorded. Presenting and near visual acuity were measured and cause of visual impairment (VI) determined. In this sample, 113/614 participants (18.4%) presented with distance VI, 16 (2.6%) with distance blindness, and 221 (47.6%) with near VI. Older participants and those with near VI were more likely to indicate that it is hard to have an eye examination due to travel time, lack of transport and transport costs. Female participants and those from underserved areas were more likely to report shame and fear of jealousy from others when asked about their attitudes towards spectacles. Participants reporting that they were willing to pay higher amounts for testing and spectacles/treatment also reported higher education levels, higher household incomes and were more likely to be male. A quarter of participants (25.9%) indicated that they did not like having an eye examination because their reading and writing was poor. People attending outreach eye care clinics in PNG reported finding it difficult to attend eye health services due to transport difficulties and anticipated high costs. Negative attitudes towards spectacles were also prevalent, and negative perceptions appeared more frequently among older participants and those with less education.

  7. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  8. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  9. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life

    DEFF Research Database (Denmark)

    Rasmussen, Marie Louise Roed

    2010-01-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due...... to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. THE PURPOSE OF THE PHD THESIS WAS: To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique...... and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity...

  10. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    Directory of Open Access Journals (Sweden)

    J. J. Gu

    2006-01-01

    Full Text Available Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the control system to drive the artificial eye to move with the natural eye. The second generation model removes the impractical usage of the eye glass frame and uses the human brain EOG (electro-ocular-graph signal picked up by electrodes placed on the sides of a person's temple to carry out the same eye movement detection and control tasks as mentioned above. Theoretical issues on sensor failure detection and recovery, and signal processing techniques used in sensor data fusion, are studied using statistical methods and artificial neural network based techniques. In addition, practical control system design and implementation using micro-controllers are studied and implemented to carry out the natural eye movement detection and artificial robotic eye control tasks. Simulation and experimental studies are performed, and the results are included to demonstrate the effectiveness of the research project reported in this paper.

  11. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    International Nuclear Information System (INIS)

    Park, J; Lee, J; Kim, H; Kim, I; Ye, S

    2015-01-01

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm 2 applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield

  12. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Park, J; Lee, J [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Kim, H [Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, I [Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ye, S [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2015-06-15

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.

  13. Structure and ultrastructure of eyes and brains of Thalia democratica (Thaliacea, Tunicata, Chordata).

    Science.gov (United States)

    Braun, Katrin; Stach, Thomas

    2017-10-01

    Salps are marine planktonic chordates that possess an obligatory alternation of reproductive modes in subsequent generations. Within tunicates, salps represent a derived life cycle and are of interest in considerations of the evolutionary origin of complex anatomical structures and life history strategies. In the present study, the eyes and brains of both the sexual, aggregate blastozooid and the asexual, solitary oozooid stage of Thalia democratica (Forskål, ) were digitally reconstructed in detail based on serial sectioning for light and transmission electron microscopy. The blastozooid stage of T. democratica possesses three pigment cup eyes, situated in the anterior ventral part of the brain. The eyes are arranged in a way that the optical axes of each eye point toward different directions. Each eye is an inverse eye that consists of two different cell types: pigment cells (pigc) and rhabdomeric photoreceptor cells (prcs). The oozooid stage of T. democratica is equipped with a single horseshoe-shaped eye, positioned in the anterior dorsal part of the brain. The opening of the horseshoe-shaped eye points anteriorly. Similar to the eyes of the blastozooid, the eye of the oozooid consists of pigment cells and rhabdomeric photoreceptor cells. The rhabdomeric photoreceptor cells possess apical microvilli that form a densely packed presumably photosensitive receptor part adjacent to the concave side of the pigc. We suggest correspondences of the individual eyes in the blastozooid stage to respective parts of the single horseshoe-shaped eye in the oozooid stage and hypothesize that the differences in visual structures and brain anatomies evolved as a result of the aggregate life style of the blastozooid as opposed to the solitary life style of the oozooid. © 2017 Wiley Periodicals, Inc.

  14. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  15. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  16. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    Science.gov (United States)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  17. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  18. Herpetic Eye Disease in a Public Eye Hospital in Nigeria | Nwosu ...

    African Journals Online (AJOL)

    Objective: To determine the aetiology, pattern and complications of herpetic eye disease seen at the Guinness Eye Centre, Onitsha, Nigeria. Materials and Methods: The case files of all patients with herpetic eye disease who presented at the centre between January 1998 and December 2003 were reviewed. Information on ...

  19. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  20. Degeneration of rapid eye movement sleep circuitry underlies rapid eye movement sleep behavior disorder.

    Science.gov (United States)

    McKenna, Dillon; Peever, John

    2017-05-01

    During healthy rapid eye movement sleep, skeletal muscles are actively forced into a state of motor paralysis. However, in rapid eye movement sleep behavior disorder-a relatively common neurological disorder-this natural process is lost. A lack of motor paralysis (atonia) in rapid eye movement sleep behavior disorder allows individuals to actively move, which at times can be excessive and violent. At first glance this may sound harmless, but it is not because rapid eye movement sleep behavior disorder patients frequently injure themselves or the person they sleep with. It is hypothesized that the degeneration or dysfunction of the brain stem circuits that control rapid eye movement sleep paralysis is an underlying cause of rapid eye movement sleep behavior disorder. The link between brain stem degeneration and rapid eye movement sleep behavior disorder stems from the fact that rapid eye movement sleep behavior disorder precedes, in the majority (∼80%) of cases, the development of synucleinopathies such as Parkinson's disease, dementia with Lewy bodies, and multiple system atrophy, which are known to initially cause degeneration in the caudal brain stem structures where rapid eye movement sleep circuits are located. Furthermore, basic science and clinical evidence demonstrate that lesions within the rapid eye movement sleep circuits can induce rapid eye movement sleep-specific motor deficits that are virtually identical to those observed in rapid eye movement sleep behavior disorder. This review examines the evidence that rapid eye movement sleep behavior disorder is caused by synucleinopathic neurodegeneration of the core brain stem circuits that control healthy rapid eye movement sleep and concludes that rapid eye movement sleep behavior disorder is not a separate clinical entity from synucleinopathies but, rather, it is the earliest symptom of these disorders. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and

  1. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  2. Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections

    Science.gov (United States)

    ... Antibiotics for eye injections; and Punctal plugs for dry eye . This is the fourth in a series of ... why patients and their ophthalmologists should discuss treating dry eye with punctal plugs only after other treatment options ...

  3. Spectacle-related eye injuries, spectacle-impact performance and eye protection.

    Science.gov (United States)

    Hoskin, Annette K; Philip, Swetha; Dain, Stephen J; Mackey, David A

    2015-05-01

    The aim was to review the prevalence of spectacle-related ocular trauma and the performance of currently available spectacle materials and to identify the risk factors associated with spectacle-related ocular trauma. A literature review was conducted using Medline, Embase and Google with the keywords 'eyeglasses' OR 'spectacles' AND 'ocular injury' / 'eye injury'/ 'eye trauma' / 'ocular trauma'. Articles published prior to 1975 were excluded from this review because of advances in spectacle lens technology and Food and Drug Administration legislative changes requiring impact resistance of all prescription spectacle lenses in the United States. Six hundred and ninety-five individual ocular traumas, for which spectacles contributed to or were the main cause of injury, were identified in the literature. Eye injuries occurred when spectacles were worn in sports, in which medium- to high-impact energies were exerted from balls, racquets or bats and/or as a result of a collision with another player. Frame, lens design and product material choice were found to be associated with ocular injury, with polycarbonate lenses cited as the material of choice in the literature. International, regional and national standards for spectacle lenses had a wide range of impact requirements for prescription spectacle lenses, sports eye protection and occupational eye protection. Spectacle-related injury represents a small but preventable cause of ocular injury. With the increasing numbers of spectacle wearers and calls to spend more time outdoors to reduce myopia, spectacle wearers need to be made aware of the potential risks associated with wearing spectacles during medium- to high-risk activities. At particular risk are those prone to falls, the functionally one-eyed, those who have corneal thinning or have had previous eye surgery or injury. With increased understanding of specific risk factors, performance guidelines can be developed for prescription spectacle eye

  4. Ultrastructural effects of silicone oil on the clear crystalline lens of the human eye.

    Science.gov (United States)

    Soliman, Wael; Sharaf, Mohamed; Abdelazeem, Khaled; El-Gamal, Dalia; Nafady, Allam

    2018-03-01

    To evaluate light and electron microscopic changes of the anterior capsule and its epithelium after clear lens extraction of vitrectomized myopic eyes with silicone oil tamponade. This prospective, controlled, non-randomized, interventional study included 20 anterior lens capsular specimens that were excised during combined clear lens extraction and silicone oil removal from previously vitrectomized highly myopic patients with silicone oil tamponade for previous retinal detachment surgeries. The specimens were examined via light microscopy and electron microscopy and compared with 20 anterior capsule specimens removed during clear lens extraction of non-vitrectomized highly myopic eyes. Light microscopic examination of clear lens anterior capsule specimens of vitrectomized myopic eyes filled with silicone oil showed relatively more flat cells with irregular outline of lens' epithelial cells with wide intercellular spaces, deeply stained nuclei, and multiple intracytoplasmic vacuoles. Scanning electron microscopy revealed collagenous surfaces filled with multiple pits, depressions, and abnormal deposits. Transmission electron microscopy revealed lens epithelial cells with apoptotic changes, many cytoplasmic vacuoles, and filopodia-like protrusions between lens epithelial cells and the capsule. Epithelial proliferation and multilayering were also observed. silicone oil may play a role in the development of apoptotic and histopathological changes in clear lens epithelial cells. Clarity of the lens at the time of silicone oil removal does not indicate an absence of cataractous changes. We found justification of combined clear lens extraction and silicone oil removal or combined phacovitrectomy when silicone oil injection is planned, but further long-term studies with larger patient groups are required.

  5. Upgradation and modernization of eye banking services: Integrating tradition with innovative policies and current best practices.

    Science.gov (United States)

    Tandon, Radhika; Singh, Archita; Gupta, Noopur; Vanathi, M; Gupta, Vivek

    2017-02-01

    The purpose of this study is to review the history and evolution of the National Eye Bank (NEB) and analyze the impact over the years and report the outcome of the invested resources. Review of archival material, records, project reports, policy and procedures' manuals, and publications was done. Descriptive and analytical processing of data obtained was undertaken. Parameters evaluated included total collection, transplantation, utilization rates of donor cornea, changing trends over time in terms of numbers and duration of recipients waiting, impactful research translated into changes in standard operating protocols, new facilities, and subsequent effects on numbers or quality assurance measures and overview of major achievements. Periodic situational analysis with contextual relevance and interpretation of outcomes was done pertaining to national goals and international standards. The NEB and cornea services have played a key leadership role in furthering the development of eye banking and corneal transplantation services. The contribution extends beyond routine patient care to education, training, generation of resources, advocacy, and policymaking. In quantifiable terms, the overall performance has steadily increased over the years. Major contributions include training of doctors, eye bank staff and corneal surgeons, introduction of innovative techniques for corneal transplantation, setting of national standards for eye banking and provision of preservation media, customized corneal, and ocular surface cell replacement therapy in collaboration with other departments and institutes. The eye banking and corneal transplantation facilities have evolved with time providing quality services, modernized as appropriate with updated knowledge and incorporating technological advances supported by the systematic evidence-based approach.

  6. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  7. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  8. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ... Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms Causes of ...

  10. Multiple nuclear and mitochondrial genotyping identifies emperors and large-eye breams (Teleostei : Lethrinidae) from New Caledonia and reveals new large-eye bream species

    OpenAIRE

    Borsa, Philippe; Collet, Adeline; Carassou, Laure; Ponton, Dominique; Chen, W. J.

    2010-01-01

    International audience; Species identification is fundamental to address questions about community ecology, biodiversity, conservation and resource management, at any life history stage. Current studies on fish larval ecology of tropical species are hampered by the lack of reliable and effective tools for identifying larvae at the species level. Emperors and large-eye breams comprise fish species from the perciform fish family Lethrinidae. They inhabit coastal and coral-reef habitats of the t...

  11. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  12. [Study on A White-Eye Pattern in Dielectric Barrier Discharge by Optical Emission Spectrum].

    Science.gov (United States)

    Zhu, Ping; Dong, Li-fang; Yang, Jing; Zhang, Yu; Zhang, Chao

    2015-06-01

    The white-eye pattern was firstly observed and investigated in a dielectric barrier discharge system in the mixture of argon and air whose content can be varied whenever necessary, and the study shows that the white-eye cell is an interleaving of three different hexagonal sub-structures: the center spot, the halo, and the ambient spots. The white-eye pattern is observed at a lower applied voltage. In this experiment, the heat capacity of water is high so that the water in water electrode is good at absorbing heat. In the process of pattern discharging the gas gap didn't increase its temperature, and the discharging phenomenon of this pattern has not changed. The temperature of the water electrodes almost keeps unchanged during the whole experiment, which is advantageous for the long-term stable measurement. Pictures recorded by ordinary camera with long exposure time in the same argon content condition show that the center spot, the halo, and the ambient spots og the white-eye pattern have different brightness, which may prove that their plasma states are different. And, it is worth noting that there are obvious differences of brightness not only on the center spot, the halo, and the ambient spots at the same pressure but also at the different pressure, which shows that its plasma state also changed with the variation of the pressure. Given this, in this experiment plasma temperatures of the central spot, halo, and ambient spots in a white-eye pattern at different gas pressure were studied by using optical emission spectra. The molecular vibration temperature is investigated by the emission spectra of nitrogen band of second positive system ( C3Πu --> B3Πg ). The electron excitation temperature is researched by the relative intensity ratio method of spectral lines of Ar I 763. 51 nm (2P6 --> 1S5) and Ar I 772. 42 nm (2P2 --> 1S3). The electronic density is investigated by the broadening of spectral line 696.5 nm. Through the analysis of experimental results, it

  13. A mouse dry eye model induced by topical administration of the air pollutant particulate matter 10.

    Science.gov (United States)

    Li, Juan; Tan, Gang; Ding, Xiaoyan; Wang, Yahong; Wu, Anhua; Yang, Qichen; Ye, Lei; Shao, Yi

    2017-12-01

    To introduce a novel dry eye mouse model induced by topical administration of the air pollutant particulate matter 10 (PM 10 ). A total of 60 male BALB/c mice were used in this study and divided into two groups: group A (PBS eye drops, n=30) and group B (PM 10 eye drop group, n=30). Each treatment was dosed four times a day, every time 50ul with the concentration of 5mg/ml PM10, for 14 consecutive days in the right eye. The clinical manifestations of dry eye were measured before therapy and 4, 7 and 14days post-treatment respectively, which included the tear volume, tear break-up (BUT) time, corneal fluorescein staining, rose bengal staining, Lissamine Green staining and inflammatory index. Eye samples were collected on D14 and examined by histologic light microscopy, transmission electron microscopy (TEM) and scanning electron microscopy (SEM), corneal cytokeration 10 (K10) immunnostaining, and tumor necrosis factor-α (TNF-α), NF-κB-p65 and NF-κB Western Blot analysis. At 0d, 7d and 14d, there were no statistical changes in tear volume, BUT after treatment (P>0.05) with PBS in group A. In group B, all items showed statistical differences at each time point (Plevels of K10 and reduced number of goblet cells in the conjunctival fornix in group B. PM 10 significantly increased the levels of TNF-α, NF-κB-p65 and NF-κB in the cornea. PM 10 can damage the tear film function and cause the destruction of the structural organization of ocular surface in mice. Topical administration of PM 10 in mice induces ocular surface changes that are similar to those of dry eye in humans, representing a novel model of DES. Copyright © 2017. Published by Elsevier Masson SAS.

  14. In the eye of the beholder: eye contact increases resistance to persuasion.

    Science.gov (United States)

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  15. Using mobile electronic devices to deliver educational resources in developing countries.

    Science.gov (United States)

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  16. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Finding electronic information for health policy advocacy: a guide to improving search results.

    Science.gov (United States)

    Olsan, Tobie H; Bianchi, Carolanne; White, Pamela; Glessner, Theresa; Mapstone, Pamela L

    2011-12-01

    The success of advanced practice registered nurses' (APRNs') health policy advocacy depends on staying well informed about key issues. Searching for high-quality health policy information, however, can be frustrating and time consuming. Busy clinicians need strategies and tips to reduce information overload and to access synthesized research for evidence-based health policy. This article therefore offers APRNs practical guidelines and resources for searching electronic health policy information. Scholarly databases and Internet sites. Electronic health policy information is generated by a wide variety of public and private organizations and disseminated in hundreds of journals and Web pages. Specialty search tools are needed to retrieve the unindexed gray literature, which includes government documents, agency reports, fact sheets, standards, and statistics not produced by commercial publishers. Further, Internet users need to examine search results with a critical eye for information quality. Expertise in searching electronic health policy information is a prerequisite for developing APRNs' leadership in political arenas to influence health policy and the delivery of healthcare services. ©2011 The Author(s) Journal compilation ©2011 American Academy of Nurse Practitioners.

  18. Creation of nano eye-drops and effective drug delivery to the interior of the eye

    Science.gov (United States)

    Ikuta, Yoshikazu; Aoyagi, Shigenobu; Tanaka, Yuji; Sato, Kota; Inada, Satoshi; Koseki, Yoshitaka; Onodera, Tsunenobu; Oikawa, Hidetoshi; Kasai, Hitoshi

    2017-03-01

    Nano eye-drops are a new type of ophthalmic treatment with increased potency and reduced side effects. Compounds in conventional eye-drops barely penetrate into the eye because the cornea, located at the surface of eye, has a strong barrier function for preventing invasion of hydrophilic or large-sized materials from the outside. In this work, we describe the utility of nano eye-drops utilising brinzolamide, a commercially available glaucoma treatment drug, as a target compound. Fabrication of the nanoparticles of brinzolamide prodrug increases the eye penetration rate and results in high drug efficacy, compared with that of commercially available brinzolamide eye-drops formulated as micro-sized structures. In addition, the resulting nano eye-drops were not toxic to the corneal epithelium after repeated administration for 1 week. The nano eye-drops may have applications as a next-generation ophthalmic treatment.

  19. BullsEye

    DEFF Research Database (Denmark)

    Klokmose, Clemens Nylandsted; Kristensen, Janus Bager; Bagge, Rolf

    2014-01-01

    implemented primarily in shaders on the GPU. The techniques are realized in the BullsEye computer vision software. We demonstrate experimentally that BullsEye provides sub-pixel accuracy down to a tenth of a pixel, which is a significant improvement compared to the commonly used reacTIVision software....

  20. Registration of eye reflection and scene images using an aspherical eye model.

    Science.gov (United States)

    Nakazawa, Atsushi; Nitschke, Christian; Nishida, Toyoaki

    2016-11-01

    This paper introduces an image registration algorithm between an eye reflection and a scene image. Although there are currently a large number of image registration algorithms, this task remains difficult due to nonlinear distortions at the eye surface and large amounts of noise, such as iris texture, eyelids, eyelashes, and their shadows. To overcome this issue, we developed an image registration method combining an aspherical eye model that simulates nonlinear distortions considering eye geometry and a two-step iterative registration strategy that obtains dense correspondence of the feature points to achieve accurate image registrations for the entire image region. We obtained a database of eye reflection and scene images featuring four subjects in indoor and outdoor scenes and compared the registration performance with different asphericity conditions. Results showed that the proposed approach can perform accurate registration with an average accuracy of 1.05 deg by using the aspherical cornea model. This work is relevant for eye image analysis in general, enabling novel applications and scenarios.

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  2. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes ...

  3. Recognizing and Treating Eye Injuries

    Science.gov (United States)

    ... Eye Injuries First Aid for Eye Scratches Protective Eyewear Children’s Eye Injuries: Prevention and Care Eye Injuries ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  4. Eye readable metal hydride based hydrogen tape sensor for health applications

    NARCIS (Netherlands)

    Ngene, P.; Radeva, T.; Westerwaal, R.; Schreuders, H.; Dam, B.

    Using the change in the intrinsic optical properties of YMg-based thin films upon exposure to hydrogen, we observe the presence of hydrogen at concentrations as low as 20 ppm just by a change in color. The eye-visible color change circumvents the use of any electronics in this device, thereby making

  5. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Simmons PA

    2015-04-01

    Full Text Available Peter A Simmons, Cindy Carlisle-Wilcox, Joseph G Vehige Ophthalmology Research and Development, Allergan, Inc., Irvine, CA, USA Background: Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops.Methods: A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD to a preservative-free aqueous tear formulation (AqT UD for change in Ocular Surface Disease Index (OSDI score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT, corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments.Results: A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001 and TBUT (P≤0.005. LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events.Conclusion: In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears

  6. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    Science.gov (United States)

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  7. Immunology of the eye

    OpenAIRE

    Weronika Ratajczak; Beata Tokarz-Deptuła; Wiesław Deptuła

    2018-01-01

    The eye is an organ of sight characterized by unusual immunological properties, resulting from its anatomical structure and physiology, as well as the presence of specific elements that, through the mechanisms of innate and adaptive immunity, provide homeostasis of the eyeball. This article reviews the defensive elements of individual eye structures: conjunctiva, cornea, lacrimal gland, anterior chamber of the eye, uvea, retina and eye-associated lymphoid tissue (EALT), where we distinguish a...

  8. Choosing Wisely When It Comes to Eye Care: Punctal Plugs for Dry Eye

    Science.gov (United States)

    ... of Our 5-Part Series: Punctal Plugs for Dry Eye Making healthy lifestyle choices can help you protect ... discuss each item in detail. Punctal Plugs for Dry Eye Dry eye is a condition that millions of ...

  9. Eye Injuries at Work

    Science.gov (United States)

    ... National Standards Institute (ANSI) to meet their eye protection standards. If an eye injury occurs, see an ophthalmologist or go to the emergency room immediately, even if the eye injury appears minor. Delaying medical attention can result in permanent vision ...

  10. Transcriptome Analysis of the Planarian Eye Identifies ovo as a Specific Regulator of Eye Regeneration

    Directory of Open Access Journals (Sweden)

    Sylvain W. Lapan

    2012-08-01

    Full Text Available Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription-factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye.

  11. Transcriptome analysis of the planarian eye identifies ovo as a specific regulator of eye regeneration.

    Science.gov (United States)

    Lapan, Sylvain W; Reddien, Peter W

    2012-08-30

    Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription-factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye. Copyright © 2012 The Authors. Published by Elsevier Inc. All rights reserved.

  12. A laser-based eye-tracking system.

    Science.gov (United States)

    Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J

    2002-11-01

    This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.

  13. Eyes on the Road (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2013-03-14

    One of the first lessons new drivers learn is to keep their eyes on the road. Unfortunately, cell phones and other electronic devices are causing many drivers to lose their focus, and sometimes their lives. In this podcast, Rebecca Naumann discusses the dangers of distracted driving.  Created: 3/14/2013 by MMWR.   Date Released: 3/14/2013.

  14. Setting up a child eye care centre: the Mercy Eye Hospital, Abak ...

    African Journals Online (AJOL)

    Aim: To document and share our experience in setting up a Child Eye Care Centre within a rural mission eye hospital and document subsequent development of services. Method: The location of the project was Mercy Eye Hospital (MEH) Abak, Akwa Ibom State in the South South zone of Nigeria). Consent to commence ...

  15. Trustworthy-looking face meets brown eyes.

    Directory of Open Access Journals (Sweden)

    Karel Kleisner

    Full Text Available We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes.

  16. A review of the role of oxidative stress in the pathogenesis of eye diseases

    Directory of Open Access Journals (Sweden)

    O. A. Oduntan

    2011-12-01

    Full Text Available Free radicals, referred to as oxidants are molecules in the body with unpaired electrons, hence are unstable and ready to bond with other molecules with unpaired electrons.  They include Reactive Oxygen Species (ROS such as superoxide anion radicals (·O¯, hydrogen peroxide (H202, and hydroxyl free radicals (·OH.  Endogenous sources of ROS include metabolic and other organic processes, while exogenous sources include ultraviolet radiation and environmental toxins such as smoke.  Antioxidants (oxidant scavengers such as ascorbate, alpha-tocopherol and glutathione as well as various enzymatic compounds such as superoxide dismutase (SOD, catalase and glutathione reductase are also present in the body and in manyfoods or food supplements.  An imbalance between oxidants and antioxidants in favour of oxidantsis termed oxidative stress and can lead to cell or tissue damage and aging. Oxidative stress has been implicated in the pathogenesis of many serious systemic diseases such as diabetes, cancer and neurological disorders.  Also, laboratory and epidemiological studies have implicated oxidative stress in the pathogenesis of the majority of common serious eye diseases such as cataract, primary open angle glaucoma and age-related macular degeneration. In this article, we reviewed the current information on the roles of oxidative stress in the pathogenesis of various eye diseases and the probable roles of antioxidants.  Eye care practitioners will find this article useful as it provides information on the pathogenesis of common eye diseases. (S Afr Optom 2011 70(4 182-190

  17. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  18. Radiotherapy for the eye - Tolerance issues and therapeutic strategies for benign and malignant problems

    International Nuclear Information System (INIS)

    Brady, Luther W.

    1997-01-01

    In general, there has been a reluctance on the part of radiation oncologists to undertake the responsibilities of treatment of patients with malignant and benign diseases involving the eye and periorbital tissues. With the changing technologies in diagnosis, alternative modalities for treatment as well as the significant impact of computed tomography and magnetic imaging technologies in the management of patients with eye tumors, there has been a resurgence of interest in treating not only malignant but benign ocular diseases. The refresher course will deal with the latest developments in the diagnosis and therapy of retinoblastomas, uveal melanomas, and malignant lymphomas with emphasis on optimization dosimetry as well as treatment planning along with presentation of the utilization of radioactive eye plaques in management of malignant tumors of the eye. The effects and side effects of radiation therapy will be discussed with emphasis on electron beam, photon beam, and plaque irradiation as well as proton beam irradiation of eye diseases with emphasis on minimization of those side effects. The resurgence of interest in treating benign diseases in the eye will be covered with emphasis on the treatment of the wet type of age related macular degeneration. Finally, the course will also cover radiotherapy for other benign conditions such as pterygium, choroidal and retinal hemangiomas

  19. Prevention of Eye Injuries

    OpenAIRE

    Pashby, Tom

    1981-01-01

    In Canada 30,000 people are registered as blind; in one third of these, blindness might have been avoided. Prevention is the key to reducing the number of eye injuries and blind eyes. The role of the family physician in early identification of treatable conditions and in the education of patients is discussed, but responsibility for prevention belongs to all physicians. The success of prevention is seen in the great reduction in eye injuries in industry and sports since eye protectors have be...

  20. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  1. Penetrating eye injury in war.

    Science.gov (United States)

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.

  2. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy Beth; Ellervik, Christina; Buch, Helena

    2016-01-01

    , Danish Rural Eye Study (DRES). All DRES participants received a comprehensive general health examination preceding their eye examination, including measurement of best-corrected visual acuity (BCVA) for each eye, bilateral 45° retinal fundus photographs and further ophthalmological examination where...... indicated. RESULTS: Overall, 3826 of 3843 participants (99.6%) had bilateral visual acuity measurements. The overall frequency of VI (BCVA eye) was 0.4% (95% confidence interval, CI, 0.2-0.7%; n = 15) among all DRES participants, 0.6% (95% CI 0.3-1.0%; n = 15) among participants...... >50 years and 3.7% (95% CI 2.1-6.5%; n = 11) in participants >80 years. The primary causes of VI in the better-seeing eye were age-related macular degeneration (AMD) in 46.7% (7/15) and cataract in 26.7% (4/15). A total of 43.3% (n = 115) of participants >80 years were pseudophakic in one or both eyes...

  3. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    Directory of Open Access Journals (Sweden)

    Jin-Lan Wan

    2013-09-01

    Full Text Available AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after treatment, tear secretion volume, break-up time, corneal fluorescein staining and symptom were observed.RESULTS: After treatment, there was statistical significance for the break-up time, SⅠt and corneal fluorescein staining in both groups when compared with before treatment(PPCONCLUSION: The combined Dextran and Hypromellose eye drops and Qiming granule perform better than Dextran and Hypromellose eye drops only in treatment of dry eye.

  4. Preventing Eye Injuries

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  5. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  6. Impact of First Eye versus Second Eye Cataract Surgery on Visual Function and Quality of Life.

    Science.gov (United States)

    Shekhawat, Nakul S; Stock, Michael V; Baze, Elizabeth F; Daly, Mary K; Vollman, David E; Lawrence, Mary G; Chomsky, Amy S

    2017-10-01

    To compare the impact of first eye versus second eye cataract surgery on visual function and quality of life. Cohort study. A total of 328 patients undergoing separate first eye and second eye phacoemulsification cataract surgeries at 5 veterans affairs centers in the United States. Patients with previous ocular surgery, postoperative endophthalmitis, postoperative retinal detachment, reoperation within 30 days, dementia, anxiety disorder, hearing difficulty, or history of drug abuse were excluded. Patients received complete preoperative and postoperative ophthalmic examinations for first eye and second eye cataract surgeries. Best-corrected visual acuity (BCVA) was measured 30 to 90 days preoperatively and postoperatively. Patients completed the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ) 30 to 90 days preoperatively and postoperatively. The NEI-VFQ scores were calculated using a traditional subscale scoring algorithm and a Rasch-refined approach producing visual function and socioemotional subscale scores. Postoperative NEI-VFQ scores and improvement in NEI-VFQ scores comparing first eye versus second eye cataract surgery. Mean age was 70.4 years (±9.6 standard deviation [SD]). Compared with second eyes, first eyes had worse mean preoperative BCVA (0.55 vs. 0.36 logarithm of the minimum angle of resolution (logMAR), P < 0.001), greater mean BCVA improvement after surgery (-0.50 vs. -0.32 logMAR, P < 0.001), and slightly worse postoperative BCVA (0.06 vs. 0.03 logMAR, P = 0.039). Compared with first eye surgery, second eye surgery resulted in higher postoperative NEI-VFQ scores for nearly all traditional subscales (P < 0.001), visual function subscale (-3.85 vs. -2.91 logits, P < 0.001), and socioemotional subscale (-2.63 vs. -2.10 logits, P < 0.001). First eye surgery improved visual function scores more than second eye surgery (-2.99 vs. -2.67 logits, P = 0.021), but both first and second eye surgeries resulted in similar

  7. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.

  8. In the Eye of the Beholder-  A Survey of Models for Eyes and Gaze

    DEFF Research Database (Denmark)

    Witzner Hansen, Dan; Ji, Qiang

    2010-01-01

    Despite active research and significant progress in the last 30 years, eye detection and tracking remains challenging due to the individuality of eyes, occlusion, variability in scale, location, and light conditions. Data on eye location and details of eye movements have numerous applications and...

  9. NASA's "Eyes" Focus on Education

    Science.gov (United States)

    Hussey, K.

    2016-12-01

    NASA's "Eyes on…" suite of products continues to grow in capability and popularity. The "Eyes on the Earth", "Eyes on the Solar System" and "Eyes on Exoplanets" real-time, 3D interactive visualization products have proven themselves as highly effective demonstration and communication tools for NASA's Earth and Space Science missions. This presentation will give a quick look at the latest updates to the "Eyes" suite plus what is being done to make them tools for STEM Education.

  10. Mouse Model Resources for Vision Research

    Directory of Open Access Journals (Sweden)

    Jungyeon Won

    2011-01-01

    Full Text Available The need for mouse models, with their well-developed genetics and similarity to human physiology and anatomy, is clear and their central role in furthering our understanding of human disease is readily apparent in the literature. Mice carrying mutations that alter developmental pathways or cellular function provide model systems for analyzing defects in comparable human disorders and for testing therapeutic strategies. Mutant mice also provide reproducible, experimental systems for elucidating pathways of normal development and function. Two programs, the Eye Mutant Resource and the Translational Vision Research Models, focused on providing such models to the vision research community are described herein. Over 100 mutant lines from the Eye Mutant Resource and 60 mutant lines from the Translational Vision Research Models have been developed. The ocular diseases of the mutant lines include a wide range of phenotypes, including cataracts, retinal dysplasia and degeneration, and abnormal blood vessel formation. The mutations in disease genes have been mapped and in some cases identified by direct sequencing. Here, we report 3 novel alleles of Crxtvrm65, Rp1tvrm64, and Rpe65tvrm148 as successful examples of the TVRM program, that closely resemble previously reported knockout models.

  11. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Directory of Open Access Journals (Sweden)

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  12. Eye Pull, Eye Push: Moving Objects between Large Screens and Personal Devices with Gaze and Touch

    OpenAIRE

    Turner , Jayson; Alexander , Jason; Bulling , Andreas; Schmidt , Dominik; Gellersen , Hans

    2013-01-01

    Part 4: Gaze-Enabled Interaction Design; International audience; Previous work has validated the eyes and mobile input as a viable approach for pointing at, and selecting out of reach objects. This work presents Eye Pull, Eye Push, a novel interaction concept for content transfer between public and personal devices using gaze and touch. We present three techniques that enable this interaction: Eye Cut & Paste, Eye Drag & Drop, and Eye Summon & Cast. We outline and discuss several scenarios in...

  13. Treatment of Sjögren's syndrome-associated dry eye an evidence-based review.

    Science.gov (United States)

    Akpek, Esen Karamursel; Lindsley, Kristina B; Adyanthaya, Rohit S; Swamy, Ramya; Baer, Alan N; McDonnell, Peter J

    2011-07-01

    Outcomes-based review of reported treatment options for patients with dry eye secondary to Sjögren's syndrome (SS). Dry eye affects many individuals worldwide. Significant proportion of patients with dry eye has underlying SS, a progressive autoimmune condition. The few suggested guidelines for the treatment of dry eye are mostly based on severity of symptoms and/or clinical findings rather than on outcomes analysis, and do not differentiate SS from other causes of dry eye. METHODS AND LITERATURE REVIEW: A search strategy was developed to identify prospective, interventional studies of treatments for SS-associated dry eye from electronic databases. Eligible references were restricted to English-language articles published after 1975. These sources were augmented by hand searches of reference lists from accessed articles. Study selection, data extraction, and grading of evidence were completed independently by ≥4 review authors. The searches identified 3559 references as of August 10, 2010. After duplicate review of the titles and abstracts, 245 full-text papers were assessed, 62 of which were relevant for inclusion in the review. In the current literature on SS-associated dry eye, there is a paucity of rigorous clinical trials to support therapy recommendations. Nonetheless, the recommended treatments include topical lubricants, topical anti-inflammatory therapy, and tear-conserving strategies. The efficacy of oral secretagogues seems greater in the treatment of oral dryness than ocular dryness. Although oral hydroxychloroquine is commonly prescribed to patients with SS to alleviate fatigue and arthralgias, the literature lacks strong evidence for the efficacy of this treatment for dry eye. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Post-destructive eye surgery, associated depression at Sekuru Kaguvi Hospital Eye Unit, Zimbabwe: Pilot Study

    Directory of Open Access Journals (Sweden)

    M. M. Kawome

    2013-12-01

    Full Text Available Destructive eye surgery is associated with more complications than just loss of visual functions of the eye and aesthetics. Currently there is very little published literature on post-destructive eye surgery associated depression. Zimbabwe has been experiencing a surge in the rate of destructive eye surgery done at the National Tertiary Eye Unit. This situation could be churning out lots of unrecognized depressed clients into the community who require assistance in one form or another. Objectives: To determine the prevalence of post-destructive eye surgery associated depression among patients attending Sekuru Kaguvi Hospital Eye Unit and assess if the current management protocol of patients undergoing destructive eye surgery at the Eye Unit addresses the problem adequately. Methods: A cross-sectional study of 28 randomly selected patients who had destructive eye surgeries at Sekuru Kaguvi Hospital was conducted over five months from 1st March 2012 to end of July 2012. A structured questionnaire containing 15 questions on the following items: gender, age, diagnosis, surgical procedure done, expectations before and after surgery, adequacy of counseling given and involvement of family was used to collect data. Nine questions to assess depression were adapted from the Patient Health Questionnaire (PHQ-9. Setting:  The study was conducted at SekuruKaguvi Hospital Eye Unit, Parirenyatwa Group of Hospitals in Harare. Results:  Twenty-eight patients who underwent destructive eye surgery during the study period were selected using systematic random sampling. The gender ratio was 1:1 and the mean age was 38.7 years with a range from 24 to 65 years. Fifty percent of the patients in the study had orbital exenteration while the rest had enucleation (14% and evisceration (36%. Twenty-eight percent of the study population had depression. Conclusion: Destructive eye surgery is frequently associated with depression and our current management protocol of

  15. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  16. Over the counter (OTC) artificial tear drops for dry eye syndrome.

    Science.gov (United States)

    Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J

    2016-02-23

    Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not consider head-to-head comparisons of artificial tears with

  17. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Jing Chen

    2017-10-01

    Full Text Available AIM: To compare and analyze the effect of recombinant bovine basic fibroblast growth factor(bFGFeye drops and hydroxyl indican eye drops on the tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: A total of 115 patients(115 affected eyeswith dry eyes after age-related cataract surgery were divided into the bFGF group, the hydroxyl indican group and the blank control group by the random number table method. The blank control group was only given routine anti-inflammatory treatment, and on the basis, the bFGF group and the hydroxyl indican group were treated with bFGF eye drops and hydroxyl indican eye drops respectively. The clinical efficacy, adverse reactions, changes in scores of dry eye symptoms, Schirmer test(SⅠt, tear film break-up time(BUTand corneal fluorescein staining(CFSscores at different time points were compared among the three groups. RESULTS: The total markedly effective rates in the bFGF group(89.5%was higher than that in the hydroxyl indican group(70.3%or the blank control group(47.5%(PPPCONCLUSION: The tear film is unstable in early stage after age-related cataract surgery, and there are dry eye symptoms. The intervention with bFGF eye drops and hydroxyl indican eye drops can effectively restore the tear film stability and significantly relieve dry eye symptoms, and the effect of bFGF eye drops is more significant.

  18. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...

  19. Post-LASIK dry eye

    Science.gov (United States)

    Shtein, Roni M

    2011-01-01

    Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730

  20. Electronic compliance monitoring of topical treatment after ophthalmic surgery.

    Science.gov (United States)

    Hermann, Manuel Marcel; Ustündag, Can; Diestelhorst, Michael

    2010-08-01

    The success of many medical treatments is built on compliance. Electronic monitoring is the most accurate tool to quantify compliance by measuring adherence. In order to assess the efficiency of a recently introduced miniature monitoring device for eye drop application, we evaluated adherence in ophthalmic patients undergoing post-operative short-term topical treatment. This pilot study enrolled 30 outpatients (mean age 61.8 +/- 18.5 years) after cataract (n = 24) and glaucoma filtration surgery (n = 6) applying fixed-combination eye drops containing prednisolone and gentamicin five times daily for 2 weeks. Patients received eye drops in conventional bottles each equipped with a miniature monitoring device recording events of application. Two patients failed to bring back the monitoring device; therefore data collected from only 28 patients could be examined. Data showed highly variable results with a mean dose compliance of 50.2%. Dose compliance was below 25% in approximately one out of five patients. Four cataract patients, but no glaucoma patient, discontinued therapy prematurely. The observed mean dosage interval was calculated for each patient and ranged 4.6-19.7 h. Thirty percent of analysed dosage intervals exceeded 12.0 h. Different patterns of compliance behaviour-like early non-persistence, drug holiday and low treatment frequency could be identified and illustrated using electronic data. Age or gender did not significantly influence compliance rates. Our pilot study demonstrates successful electronic compliance monitoring using a technology capable of continuous data recording over weeks of treatment. The low compliance rate for a relevant part of the patients demonstrates the necessity to study and improve compliance in ophthalmology. In future, new application methods and electronic application devices may improve treatment response in eye care.

  1. Clinical observation of Qiming granule combined with Dextran and Hypromellose eye drops for dry eye

    OpenAIRE

    Jin-Lan Wan; Ming-Chang Zhang

    2013-01-01

    AIM: To observe the efficacy of Qiming granule combined with Dextran and Hypromellose eye drops in treatment of dry eye.METHODS: A randomized, parallel-control approach was adopted, 100 cases of dry eye patients were divided into treatment group and control group equally, observation on the treatment of 3 months. The treatment group was applied Dextran and Hypromellose eye drops combined with oral Qiming granule, simply Dextran and Hypromellose eye drops for control group. Before and after tr...

  2. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  3. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... much as it does on your eyes. ... of Health | USA.gov NIH…Turning Discovery Into Health ®

  5. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  6. About the Eye

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes ...

  7. About the Eye

    Medline Plus

    Full Text Available ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  8. simEye: computer-based simulation of visual perception under various eye defects using Zernike polynomials

    OpenAIRE

    Fink, Wolfgang; Micol, Daniel

    2006-01-01

    We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set of Zernike polynomials that are fitted to input data for the respective surfaces. A ray-tracing procedure propagates light rays using Snell’s law of refraction from an input objec...

  9. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  10. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  13. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... or child care if you're not able to take time off — just stay consistent in practicing good hygiene. Preventing pink eye in newborns Newborns' eyes are susceptible to bacteria normally present in the mother's birth canal. ...

  14. About the Eye

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ...

  15. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  16. About the Eye

    Medline Plus

    Full Text Available ... Home » NEI for Kids » About the Eye Listen All About Vision About the Eye Ask a Scientist ... you can see and make sense of the world around you. Did You Know? Vision depends on ...

  17. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  18. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  19. Inflammation in dry eye.

    Science.gov (United States)

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  20. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and ...

  1. 'An eye, for eyes - mission' - From dream to reality

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2013-10-01

    Full Text Available Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global shortage of donor corneas [2]. At this juncture Yokoo et al isolated and expanded corneal endothelial precursors using the sphere forming assay in vitro [3] and demonstrated the in vivo transplantation of these corneal endothelial precursors in a rabbit model of bullous keratopathy [4]. Following this, we studied the transportation of cadaver donor derived corneal endothelial tissue (CET from human cadaver donors in a thermoreversible gelation polymer (TGP (4 based transportation cocktail without cool preservation and demonstrated the viability of human corneal endothelial precursor (HCEP cells isolated from these CETs even after 72 hours of transportation without cool preservation [5]. This was done to suit the conditions existing in developing nations like India where hospitals might be located far from eye banks and maintaining cold chain preservation is relatively difficult. Further, these HCEPs were expanded in vitro using a polymer based expansion protocol [5]. This was the first step in the realisation of the dream of 'Eye for eyes' in a manner suitable for Indian conditions. Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global

  2. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    Science.gov (United States)

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  3. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life.

    Science.gov (United States)

    Rasmussen, Marie Louise Roed

    2010-12-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity and frequency among EA patients. We attempted to identify patients with increased risk of developing pain after EA and investigated if preoperative pain is a risk factor for a later development of phantom pain (paper III); In addition we wanted to investigate the health related quality of life, perceived stress, self rated health, job separation due to illness or disability and socio-economic position of the EA in comparison with the general Danish population (paper IV). Records on 431 EA patients, clinical ophthalmological examination and an interview study of 173 EA patients and a questionnaire answered by 120 EA patients. The most frequent indications for EA in Denmark were painful blind eye (37%) and neoplasm (34%). During the study period 1996-2003, the annual number of eye amputations was stable, but an increase in bulbar eviscerations was noticed. Orbital implants were used with an increasing tendency until 2003. The Phantom eye syndrome is frequent among EA patients. Visual hallucinations were described by 42% of the patients. The content were mainly elementary visual hallucinations, with white or colored light as a

  4. Precut cornea for Descemet's stripping endothelial keratoplasty: experience at a single eye bank.

    Science.gov (United States)

    Mohamed, Ashik; Chaurasia, Sunita; Chandragiri, Venkataswamy; Kandhibanda, Srinivas; Gunnam, Srinivas; Garg, Prashant

    2017-06-01

    The aim of the study is to describe the experience with precut facility for endothelial keratoplasty at a single eye bank affiliated to a tertiary eye care center in India. Data on precut tissues from Nov 2012 to Dec 2014 were retrospectively reviewed from the electronic database of the eye bank of a tertiary eye care center in South India. Donor characteristic data including donor age, precut and postcut endothelial cell density (ECD), recipient age, and thickness of graft were collected. The number of precuts increased from 42 in 2012 (Nov and Dec) and 422 in 2013 to 584 in 2014. Of the total of 1048 precuts, seven (0.67 %) were miscut and could not be utilized for transplants. The donor age ranged from 2 to 89 years. A mean change of 43.6 ± 325.2 cells/mm 2 in ECD was noted after cut, proportional increase in mean being 1.9 %. The change in ECD after cut was negatively correlated with ECD before cut. The recipient age ranged from 1 to 89 years. The median thickness of donor lenticule after cut was 148 µm (interquartile range 131-166 µm). Analysis of precut donor corneas from a single eye bank shows that the ECD of the processed tissues was excellent for transplantation. The tissue wastage in the hands of eye bank personal was minimal.

  5. Effect of rb-bFGF eye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery

    Directory of Open Access Journals (Sweden)

    Yu Ling

    2018-01-01

    Full Text Available AIM: To investigate the effect of recombinant bovine basic fibroblast growth factor(rb-bFGFeye drops and hydroxyl indican eye drops on tear film stability and dry eye symptoms after age-related cataract surgery. METHODS: Totally 80 patients with 80 affected eyes undergoing age-related cataract surgery in our hospital from January 2015 to October 2016 were selected as study subjects, and they were randomly divided into control group and experimental group with 40 patients(40 affected eyesin each group. The two groups were treated with hydroxyl indican eye drops and rb-bFGF eye drops, respectively. The clinical curative effect, inflammation related factors \\〖interleukin 6(IL-6, tumor necrosis factor α(TNF-α\\〗, Schirmer test(SⅠt, break-up time(BUTof tear film, corneal sodium fluorescein staining(FLand scores of dry eye symptoms in the two groups were observed. RESULTS: The total treatment effective rate of experimental group after treatment was significantly higher than that of the control group(90.0% vs 72.5%; χ2=4.021, PP>0.05. After treatment, IL-6, TNF-α, SⅠt, FL score and scores of dry eye symptoms in two groups significantly decreased while BUT significantly increased(PPCONCLUSION: In the treatment of patients after age-related cataract after surgery, rb-bFGF eye drops has more advantages over hydroxyl indican eye drops in regulating the expression of inflammatory factors, improving the tear film stability and relieving dry eye symptoms.

  6. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  7. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  8. Dry eye syndrome

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000426.htm Dry eye syndrome To use the sharing features on this page, ... second-hand smoke exposure Cold or allergy medicines Dry eye can also be caused by: Heat or ... Symptoms may include: Blurred vision Burning, itching, ...

  9. Understanding vision: students’ use of light and optics resources

    International Nuclear Information System (INIS)

    Jones, Dyan L; Zollman, Dean

    2014-01-01

    We present a qualitative study designed to examine how students construct an understanding of the human eye and vision from their knowledge of light and optics. As would be expected, vast differences are shown to exist between pre- and post-instruction students in terms of not only resource use, but also willingness to transfer their existing knowledge. However, we have found that appropriate scaffolding can facilitate resource activation and guide students to construct an understanding of vision and vision defects. (paper)

  10. The Tromsø Eye Study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Erke, Maja G; von Hanno, Therese

    2013-01-01

    Purpose:  To describe the study design and methodology of the Tromsø Eye Study (TES), and to describe visual acuity and refractive error in the study population. Methods:  The Tromsø Eye Study is a sub-study of the Tromsø Study, a population-based multipurpose longitudinal study in the municipality...... of Tromsø, Norway. The Tromsø Eye Study was a part of the sixth survey of the Tromsø Study, conducted from October 2007 through December 2008. The eye examination included information on self-reported eye diseases, assessment of visual acuity and refractive errors, retinal photography and optical coherence...

  11. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  12. RNAi-Mediated Reverse Genetic Screen Identified Drosophila Chaperones Regulating Eye and Neuromuscular Junction Morphology

    Directory of Open Access Journals (Sweden)

    Sandeep Raut

    2017-07-01

    Full Text Available Accumulation of toxic proteins in neurons has been linked with the onset of neurodegenerative diseases, which in many cases are characterized by altered neuronal function and synapse loss. Molecular chaperones help protein folding and the resolubilization of unfolded proteins, thereby reducing the protein aggregation stress. While most of the chaperones are expressed in neurons, their functional relevance remains largely unknown. Here, using bioinformatics analysis, we identified 95 Drosophila chaperones and classified them into seven different classes. Ubiquitous actin5C-Gal4-mediated RNAi knockdown revealed that ∼50% of the chaperones are essential in Drosophila. Knocking down these genes in eyes revealed that ∼30% of the essential chaperones are crucial for eye development. Using neuron-specific knockdown, immunocytochemistry, and robust behavioral assays, we identified a new set of chaperones that play critical roles in the regulation of Drosophila NMJ structural organization. Together, our data present the first classification and comprehensive analysis of Drosophila chaperones. Our screen identified a new set of chaperones that regulate eye and NMJ morphogenesis. The outcome of the screen reported here provides a useful resource for further elucidating the role of individual chaperones in Drosophila eye morphogenesis and synaptic development.

  13. Eye-movements and ongoing task processing.

    Science.gov (United States)

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  14. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    2010-10-12

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.  Created: 10/12/2010 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 10/13/2010.

  15. Neuropathic pain and dry eye.

    Science.gov (United States)

    Galor, Anat; Moein, Hamid-Reza; Lee, Charity; Rodriguez, Adriana; Felix, Elizabeth R; Sarantopoulos, Konstantinos D; Levitt, Roy C

    2018-01-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. Its epidemiology and clinical presentation have many similarities with neuropathic pain outside the eye. This review highlights the similarities between dry eye and neuropathic pain, focusing on clinical features, somatosensory function, and underlying pathophysiology. Implications of these similarities on the diagnosis and treatment of dry eye are discussed. Published by Elsevier Inc.

  16. Experimental perforating injury with high energy electrons to inhibit intraocular proliferation

    International Nuclear Information System (INIS)

    Velikay, M.; Binder, S.; Stolba, U.; Wedrich, AJ.; Datlinger, P.; Handl-Zeller, L.

    1994-01-01

    Since 1980, the fibroblast model creating experimental proliferative vitreoretinopathy has been used to evaluate the antiproliferative effect of various drugs. In previous studies radiation therapy was found to reduce effectively intraocular proliferation in this model. We therefore investigated the effect of high energy electrons in a standard perforating injury model creating a traumatic proliferative vitreoretinopathy. In 36 eyes we performed a 8 mm pars plana incision and injected 0.4 ml of 80% fibronection solution intravitreally. Ten rabbits (20 eyes) received radiation therapy with a Betatron accelerator in a total dosage of 3000 cGy to each eye divided into 10 single fractions starting on the first post-operative day. Maximum concentration of the dose was focused to the posterior vitreous. The other 9 rabbits, 18 eyes, served as control. In our perforating injury model we observed a reduction of retinal detachment rate of 72% in the controls to 55% in the treated group. The effect of radiation therapy with high energy electrons and total dosage of 3000 cGy was not statistically significant in experimental traumatic proliferative vitreoretinopathy. (au) (12 refs.)

  17. Can Operator's Thought Be Inferred from Eye Movement Data?

    International Nuclear Information System (INIS)

    Ha, Jun Su; Seong, Poong Hyun

    2010-01-01

    Correct situation awareness (SA) has been considered a crucial key to improving performance and reducing error in NPPs. There are a lot of information sources that should be monitored in nuclear power plants (NPPs), but operators have only limited capacity of attention and memory. Operators in NPPs selectively attend to important information sources to effectively develop SA when an abnormal or accidental situation occurs. Selective attention to important information sources is continued while maintaining SA as well. The authors have developed measures of attentional resource effectiveness in information searching such as FIR (Fixation to Importance Ratio) and SAE (Selective Attention Effectiveness) which represent how effectively an operator attends to important information sources. The FIR is the ratio of attentional resources (i.e. the number and the duration of eye fixations) spent on an information source to the importance of the information source as follows: Theoretically, the SAE should approach to zero for the best effectiveness. The underlying principle of the measures is that information sources should be selectively attended to according to their informational importance. The importance of information sources depends on the state of a NPP. For example, the importance of the pressurizer level for loss of coolant accident (LOCA) is different from that for steam line break (SLB). Hence, sets of importance for information sources should be evaluated for all possible events. The FIR and the SAE have also been used as performance measures in a HMI evaluation method named 'DEMIS (Difficulty Evaluation Method in Information Searching). In this study, Operator's thought is inferred with the eye movement data during complex diagnostic tasks in NPPs. SAEs are calculated with the eye movement data for all possible events (e.g., accident, incident, or transient) in NPPs. Inference of operator thought is made by analyzing the calculated SAEs. Theoretically, the event

  18. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Directory of Open Access Journals (Sweden)

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  19. The Eyes Are the Windows to the Mind: Direct Eye Gaze Triggers the Ascription of Others' Minds.

    Science.gov (United States)

    Khalid, Saara; Deska, Jason C; Hugenberg, Kurt

    2016-12-01

    Eye gaze is a potent source of social information with direct eye gaze signaling the desire to approach and averted eye gaze signaling avoidance. In the current work, we proposed that eye gaze signals whether or not to impute minds into others. Across four studies, we manipulated targets' eye gaze (i.e., direct vs. averted eye gaze) and measured explicit mind ascriptions (Study 1a, Study 1b, and Study 2) and beliefs about the likelihood of targets having mind (Study 3). In all four studies, we find novel evidence that the ascription of sophisticated humanlike minds to others is signaled by the display of direct eye gaze relative to averted eye gaze. Moreover, we provide evidence suggesting that this differential mentalization is due, at least in part, to beliefs that direct gaze targets are more likely to instigate social interaction. In short, eye contact triggers mind perception. © 2016 by the Society for Personality and Social Psychology, Inc.

  20. About the Eye

    Medline Plus

    Full Text Available ... luh) is the small, sensitive area of the retina needed for central vision. It contains the fovea. Lens is the clear part of the eye behind the iris that helps to focus light on the retina. It allows the eye to focus on both ...

  1. LASIK Eye Surgery

    Science.gov (United States)

    ... at the front of your eye — to improve vision. Normally, images are clearly focused on the retina in the back of your eye because the ... sharply, light rays focus in front of the retina and blur distant vision. You can see objects that are close fairly ...

  2. SyntEyes KTC: higher order statistical eye model for developing keratoconus.

    Science.gov (United States)

    Rozema, Jos J; Rodriguez, Pablo; Ruiz Hidalgo, Irene; Navarro, Rafael; Tassignon, Marie-José; Koppen, Carina

    2017-05-01

    To present and validate a stochastic eye model for developing keratoconus to e.g. improve optical corrective strategies. This could be particularly useful for researchers that do not have access to original keratoconic data. The Scheimpflug tomography, ocular biometry and wavefront of 145 keratoconic right eyes were collected. These data were processed using principal component analysis for parameter reduction, followed by a multivariate Gaussian fit that produces a stochastic model for keratoconus (SyntEyes KTC). The output of this model is filtered to remove the occasional incorrect topography patterns by either an automatic or manual procedure. Finally, the output of this keratoconus model is matched to that of the original model for normal eyes using the non-corneal biometry to obtain a description of keratoconus development. The synthetic data generated by the model were found to be significantly equal to the original data (non-parametric Mann-Whitney equivalence test; 145/154 passed). The variability of the synthetic data, however, was often significantly less than that of the original data, especially for the higher order Zernike terms of corneal elevation (non-parametric Levene test; p eyes with incorrect topographies. Interpolation between matched pairs of normal and keratoconic SyntEyes appears to provide an adequate model for keratoconus progression. The synthetic data provided by the proposed keratoconus model closely resembles actual clinical data and may be used for a range of research applications when (sufficient) real data is not available. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  3. Reading from electronic devices versus hardcopy text.

    Science.gov (United States)

    Hue, Jennifer E; Rosenfield, Mark; Saá, Gianinna

    2014-01-01

    The use of electronic reading devices has increased dramatically. However, some individuals report increased visual symptoms when reading from electronic screens. This investigation compared reading from two electronic devices (Amazon Kindle or Apple Ipod) versus hardcopy text in two groups of 20 subjects. Subjects performed a 20 min reading task for each condition. Both the accommodative response and reading rate were monitored during the trial. Immediately post-task, subjects completed a questionnaire concerning the ocular symptoms experienced during the task. In comparing the Kindle with hardcopy, no significant difference in the total symptom score was observed, although the mean score for the symptoms of tired eyes and eye discomfort was significantly higher with the Kindle. No significant differences in reading rate were found. When comparing the Ipod with hardcopy, no significant differences in symptom scores were found. The mean reading rate with the Ipod was significantly slower than for hardcopy while the mean lag of accommodation was significantly larger for the Ipod. Given the significant increase in symptoms with the Kindle, and larger lag of accommodation and reduced reading rate with the Ipod, one may conclude that reading from electronic devices is not equivalent to hardcopy.

  4. Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    S. Catalan

    2016-01-01

    Full Text Available Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22 and normal fellow eyes (n=22 in patients with asymmetric keratoconus and normal eyes (n=104 in healthy subjects. Areas under the curve (AUC of receiver operator characteristic (ROC curves for each variable were compared across groups to indicate their discrimination capacity. Results. Three variables were found to differ significantly between fellow eyes and normal eyes (all p<0.05: minimum corneal thickness, thinnest corneal point, and central corneal thickness. These variables combined showed a high discrimination power to differentiate fellow eyes from normal eyes indicated by an AUC of 0.840 (95% CI: 0.762–0.918. Conclusions. Our findings indicate that topographically normal fellow eyes in patients with very asymmetric keratoconus differ from the eyes of healthy individuals in terms of their corneal epithelial and pachymetry maps. This type of information could be useful for an early diagnosis of keratoconus in topographically normal eyes.

  5. Contribution of Electronic Medical Records to the Management of Rare Diseases

    Directory of Open Access Journals (Sweden)

    Dominique Bremond-Gignac

    2015-01-01

    Full Text Available Purpose. Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients’ data with ophthalmology-specific EMR. Methods. Ophthalmology-specific EMR software (Softalmo software Corilus was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. Results. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. Discussion. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Conclusion. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease.

  6. Contribution of Electronic Medical Records to the Management of Rare Diseases.

    Science.gov (United States)

    Bremond-Gignac, Dominique; Lewandowski, Elisabeth; Copin, Henri

    2015-01-01

    Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR) in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients' data with ophthalmology-specific EMR. Ophthalmology-specific EMR software (Softalmo software Corilus) was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease.

  7. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen

    2011-01-01

    Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  8. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  9. Clinical effect of 1g/L anthocyanin eye-patch for mild and moderate dry eye

    Directory of Open Access Journals (Sweden)

    Ke-Hua Wang

    2018-05-01

    Full Text Available AIM:To evaluate the clinic efficacy of 1g/L anthocyanin eye-patch for mild and moderate dry eye. METHODS: In this prospective and multicenter study, a total of 320 cases(640 eyeswith mild and moderate dry eye were enrolled from 8 Aier Eye Hospitals in Changsha, Chongqing, Wuhan and so on from October 2016 to April 2017. The patients were assigned to eye patch group(160 casesand artificial tears group(160 casesbased on random number table. The patients in eye-patch group used 1g/L of anthocyanin eye-patch for more than 6h during night sleep, while the patients in artificial tears group used polyvinyl alcohol eye drops for 4 times per day. The evaluation of symptoms and signs were conducted on 1d before the treatment and 14d after the treatment. The evaluation of symptoms adopted the Ocular Surface Disease Index(OSDI, while the observation of signs included tear secretion test(Schirmer Ⅰ test, SⅠt, first noninvasive tear breakup time(NITBUTfas well as average noninvasive tear breakup time(NITBUTavmeasured by Oculus ocular surface analyser. RESULTS: OSDI score, NITBUTf and NITBUTav in the two groups after treatment were significantly improved compared with that before treatment, and the difference had a statistical significance(PP>0.05. There was no significant difference in OSDI score, NITBUTf, NITBUTav and SⅠt between the two groups after treatment(P>0.05.CONCLUSION: The 1g/L anthocyanin eye-patch has similar efficacy with artificial tears for mild and moderate dry eye, which can effectively improve the symptoms and tear film stability.

  10. Development of an improved dosemeter for assessments of risk to the eye

    International Nuclear Information System (INIS)

    Eakins, J.S.; Gilvin, P.J.; Hager, L.G.; Tanner, R.J.

    2014-01-01

    To develop an improved dosemeter to assess photon and beta exposures of the eye lens, and in response to issues surrounding the preferred values of H lens to be used for guiding operational radiation protection, a programme of re-optimization of the current PHE thermoluminescence dosemeter has been performed. In particular, refinements of the filter located in front of the sensitive 7 LiF:Mg,Cu,P element have been considered, so that the dose response characteristics of the device provide a better and more conservative estimate of risk. The investigation was performed using the Monte Carlo modelling software MCNP5, to produce a final design that featured a filter containing a 9.5 mm diameter polypropylene hemisphere truncated to a maximum thickness of 3.0 mm. The responses of this design in photon and electron fields are presented here, contrasted against those of the existing PHE eye dosemeter, with respect to the operational quantity H p (3,E,θ) and both current and suggested values for the absorbed dose per fluence risk profile for the lens of the eye. - Highlights: • A programme of re-optimization of the current PHE eye dosemeter has been performed. • A design featuring a truncated hemispherical filter was found to be optimal. • The shape of the filter better resembles the rotational profile of the eye. • Response characteristics depend on the calibration conditions taken to provide the best risk estimate

  11. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  12. Comparison of eye morphology and retinal topography in two species of new world vultures (Aves: Cathartidae)

    DEFF Research Database (Denmark)

    Lisney, Thomas J.; Stecyk, Karyn; Kolominsky, Jeffrey

    2013-01-01

    Vultures are highly reliant on their sensory systems for the rapid detection and localization of carrion before other scavengers can exploit the resource. In this study, we compared eye morphology and retinal topography in two species of New World vultures (Cathartidae), turkey vultures (Cathartes...... aura), with a highly developed olfactory sense, and black vultures (Coragyps atratus), with a less developed sense of olfaction. We found that eye size relative to body mass was the same in both species, but that black vultures have larger corneas relative to eye size than turkey vultures. However......, the overall retinal topography, the total number of cells in the retinal ganglion cell layer, peak and average cell densities, cell soma area frequency distributions, and the theoretical peak anatomical spatial resolving power were the same in both species. This suggests that the visual systems of these two...

  13. On Biometrics With Eye Movements.

    Science.gov (United States)

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  14. What do your eyes say? Bridging eye movements to consumer behavior

    Directory of Open Access Journals (Sweden)

    Pedro Rosa

    2015-07-01

    Full Text Available Eye tracking (ET is a technique that has been progressively employed to study the influence of visual stimuli on attentional processes and consumer behavior. The goals of the present theoretical article are fourfold and are based on an extensive literature revision. First, a brief historical review of ET methodology is introduced, presenting the evolution of ET techniques from the ancient proto-eye trackers to the “fresh” state-of-theart eye ET devices. Second, the basics of ET are clarified through a simplified technical and mathematical explanation. Third, the triad eye movement-attention-consumer behavior is made clear, grounded on attention, interest, desire, and action (AIDA theoretical model. Fourth, the most used oculometrics in marketing studies are explained and distinguished The present article addresses a number of technical and methodological issues by discussing challenges involved in ET systems and giving some guidelines for those who intend to apply ET to infer cognitive and emotional processes.

  15. Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study

    OpenAIRE

    Almeida, Marina Storani de; Carvalho, Luis Alberto

    2007-01-01

    Current ophthalmic technology allows the manipulation of eye components, such as anterior cornea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulat...

  16. Keratorefractive Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Eyes

    Directory of Open Access Journals (Sweden)

    Zhiyu Du

    2016-01-01

    Full Text Available Purpose. To evaluate high intensity focused ultrasound (HIFU as an innovation and noninvasive technique to correct presbyopia by altering corneal curvature in the rabbit eye. Methods. Eighteen enucleated rabbit eyes were treated with a prototype HIFU keratoplasty. According to the therapy power, these eyes were divided three groups: group 1 (1 W, group 2 (2 W, and group 3 (3 W. The change in corneal power was quantified by a Sirius Scheimpflug camera. Light microscopy (LM and transmission electron microscopy (TEM were performed to determine the effect on the corneal stroma. Results. In the treated eyes, the corneal curvature increases from 49.42 ± 0.30 diopters (D and 48.00 ± 1.95 D before procedure to 51.37 ± 1.11 D and 57.00 ± 1.84 D after HIFU keratoplasty application in groups 1 and 3, respectively. The major axis and minor axis of the focal region got longer when the powers of the HIFU got increased; the difference was statistically significant (p<0.05. LM and TEM showed HIFU-induced shrinkage of corneal stromal collagen with little disturbance to the underlying epithelium. Conclusions. We have preliminarily exploited HIFU to establish a new technique for correcting presbyopia. HIFU keratoplasty will be a good application prospect for treating presbyopia.

  17. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. Did You Know? Vision depends on your brain as much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  18. An eye movement study for identification of suitable font characters for presentation on a computer screen.

    Science.gov (United States)

    Banerjee, Jayeeta; Majumdar, Dhurjati; Majumdar, Deepti; Pal, Madhu Sudan

    2010-06-01

    We are experiencing a shifting of media: from the printed paper to the computer screen. This transition is modifying the process of how we read and understand a text. It is very difficult to conclude on suitability of font characters based upon subjective evaluation method only. Present study evaluates the effect of font type on human cognitive workload during perception of individual alphabets on a computer screen. Twenty six young subjects volunteered for this study. Here, subjects have been shown individual characters of different font types and their eye movements have been recorded. A binocular eye movement recorder was used for eye movement recording. The results showed that different eye movement parameters such as pupil diameter, number of fixations, fixation duration were less for font type Verdana. The present study recommends the use of font type Verdana for presentation of individual alphabets on various electronic displays in order to reduce cognitive workload.

  19. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.

    Science.gov (United States)

    Lesperance, Marielle; Inglis-Whalen, M; Thomson, R M

    2014-02-01

    To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with(125)I, (103)Pd, or (131)Cs seeds, and to investigate doses to ocular structures. An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20-30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%-10% and 13%-14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%-17% and 29%-34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model

  20. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    International Nuclear Information System (INIS)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-01-01

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with 125 I, 103 Pd, or 131 Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up

  1. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    Science.gov (United States)

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    Science.gov (United States)

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  3. Simulation of wave propagation inside a human eye: acoustic eye model (AEM)

    Science.gov (United States)

    Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.

    2018-02-01

    The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.

  4. Efficacy of Intracameral Moxifloxacin Endophthalmitis Prophylaxis at Aravind Eye Hospital.

    Science.gov (United States)

    Haripriya, Aravind; Chang, David F; Namburar, Sathvik; Smita, Anand; Ravindran, Ravilla D

    2016-02-01

    To compare the rate of postoperative endophthalmitis before and after initiation of intracameral (IC) moxifloxacin for endophthalmitis prophylaxis in patients undergoing cataract surgery. Retrospective, clinical registry. All charity and private patients (116 714 eyes) who underwent cataract surgery between February 15, 2014, and April 15, 2015, at the Madurai Aravind Eye Hospital were included. Group 1 consisted of 37 777 eyes of charity patients who did not receive IC moxifloxacin, group 2 consisted of 38 160 eyes of charity patients who received IC moxifloxacin prophylaxis, and group 3 consisted of 40 777 eyes of private patients who did not receive IC moxifloxacin. The electronic health record data for each of the 3 groups were analyzed, and the postoperative endophthalmitis rates were statistically compared. The cost of endophthalmitis treatment (groups 1 and 2) and the cost of IC moxifloxacin prophylaxis (group 2) were calculated. Postoperative endophthalmitis rate before and after initiation of IC moxifloxacin endophthalmitis treatment cost. Manual, sutureless, small incision cataract surgery (M-SICS) accounted for approximately all of the 75 937 cataract surgeries in the charity population (97%), but only a minority of the 40 777 private surgeries (21% M-SICS; 79% phacoemulsification). Thirty eyes in group 1 (0.08%) and 6 eyes in group 2 (0.02%) were diagnosed with postoperative endophthalmitis (P < 0.0001). The group 3 endophthalmitis rate was 0.07% (29 eyes), which was also higher than the second group's rate (P < 0.0001). There were no adverse events attributed to IC moxifloxacin in group 2. The total cost of treating the 30 patients with endophthalmitis in group 1 was virtually identical to the total combined cost in group 2 of routine IC moxifloxacin prophylaxis and treatment of the 6 endophthalmitis cases. Routine IC moxifloxacin prophylaxis achieved a highly significant, 4-fold reduction in postoperative endophthalmitis in patients undergoing M

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet ...

  6. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  7. Effect of school eye health promotion on children's eye health literacy in Vietnam.

    Science.gov (United States)

    Paudel, Prakash; Yen, Phung Thi; Kovai, Vilas; Naduvilath, Thomas; Ho, Suit May; Giap, Nguyen Viet; Holden, Brien A

    2017-10-06

    Health promotion intervention in schools is a useful strategy to improve students' health awareness. The purpose of this study was to assess the effect of eye health promotion interventions on eye health literacy in school children in Vietnam. A piloted questionnaire was administered to 300 children from five secondary schools in Ba Ria-Vung Tau, Vietnam at baseline and re-administered after the eye health promotion interventions. McNemar chi-square and logistic regression were used for statistical analysis. A total of 300 children aged 12-15 years (mean, 13.3 ± 1.3 years; 60% female) participated in the baseline survey. The participation rate in the post-health promotion survey was 94.7%. After the health promotion interventions, number of children who had correct eye health knowledge increased by 10-20% (60-75% to 70-95%), more children reported having had an eye examination (63.3% to 84.7%; p promotion interventions significantly improve eye health knowledge, attitudes and practices of school children. Additionally, participation of parents and teachers as change agents may further improve children's health literacy. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Moving eyes and naming objects

    NARCIS (Netherlands)

    Meulen, F.F. van der

    2001-01-01

    The coordination between eye movements and speech was examined while speakers were naming objects. Earlier research has shown that eye movements reflect on the underlying visual attention. Also, eye movements were found to reflect upon not only the visual and conceptual processing of an object, but

  9. External eye symptoms in indoor environments.

    Science.gov (United States)

    Wolkoff, P

    2017-03-01

    Eye irritation, for example dry or irritated eyes, is generally among top three reported symptoms in office-like environments, in particular among workplaces with cognitive demanding visual display unit (VDU) work. The symptoms are especially among middle and advanced ages and particularly among women more than men. The symptoms are also among the most commonly reported complaints in the eye clinic. To be in a position to interpret the high prevalence of eye symptoms, a multidisciplinary and integrated approach is necessary that involves the external eye physiology (separate from internal eye effects), eye diseases (evaporative dry eye (DE), aqueous-deficient DE, and gland dysfunctions), and risk factors that aggravate the stability of precorneal tear film (PTF) resulting in hyperosmolarity and initiation of inflammatory reactions. Indoor environmental, occupational and personal risk factors may aggravate the PTF stability; factors such as age, contact lenses, cosmetics, diet, draft, gender, low humidity and high temperature, medication, outdoor and combustion pollutants, and VDU work. Psychological stressors may further influence the reporting behavior of eye symptoms. The impact of the risk factors may occur in a combined and exacerbating manner. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  10. Pigment dispersion glaucoma induced by the chafing effect of intraocular lens haptics in Asian eyes.

    Science.gov (United States)

    Hong, Ying; Sun, Yan-Xiu; Qi, Hong; Zhou, Ji-Chao; Hao, Yan-Sheng

    2013-03-01

    To study the possible mechanism and treatment for pigment dispersion glaucoma (PDG) caused by single-piece acrylic (SPA) intraocular lens (IOL) ciliary sulcus fixation in Asian eyes. Patients referred for PDG caused by SPA IOL ciliary sulcus fixation to our hospital from April 2005 to June 2011 were included. The patients' general information, IOL type, interval between initial surgery and PDG occurrence, examination findings, antiglaucoma medicine regimen and surgical interventions were recorded. In total, six eyes from five Chinese patients were included in this study. The intraocular pressure (IOP) increased 19-30 days after cataract surgery and was not satisfactorily controlled with antiglaucoma medication. Dense pigmentation was deposited on the IOLs and on the anterior chamber angle. IOL haptic chafing was noted on the rear iris surface. IOL repositioning in the capsular bag was performed in three eyes and was combined with trabeculectomy in two eyes with progressive glaucoma. An IOL exchange with three-piece IOL ciliary sulcus fixation was performed in the other three eyes. Scanning electron microscopy of the explanted IOLs demonstrated a rough edge on the IOL haptics. SPA IOLs were not suitable for ciliary sulcus fixation. The chafing effect of the IOL haptics on the posterior iris pigment epithelium could induce PDG in Asian eyes. IOLs should be positioned in the capsular bag or a three-piece IOL should be used instead.

  11. Efficacy of corneal eye shields in protecting patients' eyes from laser irradiation.

    Science.gov (United States)

    Russell, S W; Dinehart, S M; Davis, I; Flock, S T

    1996-07-01

    The continuing development of new types and applications of lasers has appeared to surpass the development of specific eye protection for these lasers. There are a variety of eye shields on the market, but few are specifically designed for laser protection. Our purpose was to test a variety of eye shields by two parameters, light transmission and temperature rise, and to determine from these measurements the most protective shield for patients. We tested four plastic shields, one metal shield, and two sets of tanning goggles for temperature rise and light transmission when irradiated with a beam from a flashlamp-pumped, pulsed-dye laser. The temperature rise at the surface of the shield opposite the laser impacts was no more than 0.2 degree C in any case. White light was transmitted at significant levels through several of the shields, but yellow light transmittance was noted only through the green eye shield. Our measurements indicate that all except the green shield appeared safe from transmission of the 585-nm radiant energy. However, the optimal laser eye shield, in our opinion, would be a composite of several different shields' characteristics.

  12. More Than Meets the Eye: The Eye and Migraine-What You Need to Know.

    Science.gov (United States)

    Digre, Kathleen B

    2018-05-02

    Migraine has long been associated with disturbances of vision, especially migraine with aura. However, the eye plays an important role in sensory processing as well. We have found that the visual quality of life is reduced in migraine. In this review, we discuss how the migraine and eye pain pathways are similar and affect many of the common complaints which are seen in ophthalmology and neuro-ophthalmology offices, such as dry eye and postoperative eye pain. We also review other related phenomena, including visual snow and photophobia, which also are related to altered sensory processing in migraine.

  13. An improved likelihood model for eye tracking

    DEFF Research Database (Denmark)

    Hammoud, Riad I.; Hansen, Dan Witzner

    2007-01-01

    While existing eye detection and tracking algorithms can work reasonably well in a controlled environment, they tend to perform poorly under real world imaging conditions where the lighting produces shadows and the person's eyes can be occluded by e.g. glasses or makeup. As a result, pixel clusters...... associated with the eyes tend to be grouped together with background-features. This problem occurs both for eye detection and eye tracking. Problems that especially plague eye tracking include head movement, eye blinking and light changes, all of which can cause the eyes to suddenly disappear. The usual...... approach in such cases is to abandon the tracking routine and re-initialize eye detection. Of course this may be a difficult process due to missed data problem. Accordingly, what is needed is an efficient method of reliably tracking a person's eyes between successively produced video image frames, even...

  14. Efficacy and safety of short-term application of pranoprofen eye drops for senile patients with dry eyes

    Directory of Open Access Journals (Sweden)

    Yu-Chan Li

    2018-06-01

    Full Text Available AIM:To investigate the efficacy and safety of short-term application of pranoprofen eye drops in the treatment of dry eyes in senile patients. METHODS: Totally 100 elderly patients with dry eyes treated in our hospital from June 2016 to May 2017 were randomly divided into 2 groups. All cases were bilateral onset, and the right eyes were marked as the observation eyes. The 50 eyes in the observation group were treated with 1g/L pranoprofen eye drops combined with 1g/L sodium hyaluronate eye drops, while 50 in the control group were treated with 1g/L sodium hyaluronate eye drops. The results of Schirmer Ⅰ, ocular surface disease index(OSDI, break-up time(BUT, ocular surface staining(OSS, human leukocyte antigen-DR(HLA-DRand CD11b in conjunctival epithelial cells before and at 2wk after treatment, and adverse reactions in 2 groups were observed. RESULTS: Before treatment, results of Schirmer I, OSDI, BUT, OSS, HLA-DR and CD11b in the two groups were similar, there were no statistically significant differences(P>0.05. After treatment, OSDI, OSS, HLA-DR, CD11b significantly decreased, BUT significantly increased in both groups, the differences were statistically significant(PPPCONCLUSION: Short term application of pranoprofen eye drops can effectively enhance the efficacy in treating elderly patients with dry eyes, release clinical symptoms, and the therapeutic mechanism may be related to the inhibitory effect on HLA-DR.

  15. Naked-eye astronomy in mass tourism

    Directory of Open Access Journals (Sweden)

    Tadić Milutin

    2016-01-01

    Full Text Available This paper considers the possibility of developing astro-tourism in small countries such as Serbia and other Balkan countries, with "discreet" astro-tourism reduced to naked-eye astronomy as part of mass tourism rather than elite tourism that is realized through specialized programs with spacecraft and space stations, spectacular planetariums and observatories with giant telescopes. The specific relationship between the virtual and the real world is highlighted in this paper especially when considering younger generations. Furthermore, the differences in the way stars are perceived by astronomers and "ordinary" tourists or non-astronomers is also emphasized. Tourists are not enchanted by celestial bodies themselves, but by a complete scene, which consists of integrated skyscapes and landscapes, as a complex stage where in various combinations and forms these celestial bodies are observed, and of their own experience. These complex sky-earth landscapes, astro-landscapes, present astro-tourism resources of the small countries like Serbia, provided that a tourist can "read" their astronomical text. In this regard, Belgrade was used as the example for drafting a "package" of astronomical information that can be easily prepared and adapted according to the needs of a particular group, so that every tourist may know what can be seen, where and when. With the help of a rotating star map (planisphere, visitors may observe the sky with the naked eye.

  16. Impact of dry eye on work productivity.

    Science.gov (United States)

    Yamada, Masakazu; Mizuno, Yoshinobu; Shigeyasu, Chika

    2012-01-01

    The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism. A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years) were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed. The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P work productivity loss associated with dry eye was estimated to be USD 741 per person. Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.

  17. Eyes, Bulging (Proptosis)

    Science.gov (United States)

    ... Early Breast Cancer to Avoid Chemo Could a Blood Test Spot Lung Cancer Early? Experimental Drug Shows 'Modest' Benefit ... often done when bulging affects only one eye. Blood tests to measure how well the thyroid is working are done when ... When bulging leads to severe dry eyes, lubrication with artificial tears is needed to ...

  18. Differentiation of the guinea pig eye: nuclear ultrastructure, template activity and DNA content

    International Nuclear Information System (INIS)

    Schmalenberger, B.

    1980-01-01

    Nuclei of various cell types in the eye of embryonal and adult Guinea pigs were studied by means of electron microscopy, cytophotometry and autoradiography. Striking differences in condensation and arrangement of chromatin were found between the different tissues and cells. Several nuclear types were analyzed quantitatively with regard to their content of condensed and decondensed chromatin by means of electron microscopic morphometry. Structural differences in chromatin organization coincided with different nuclear DNA contents in various cell types of the retina, such as bipolar cells, Mueller cells, rods and cones, and the pigmented epithelium. The differences between DNA-Feulgen means obtained by cytophotometric analysis were highly significant. Template activity as shown by 3 H-uridine incorporation made evident than the rate of RNA synthesis is positively correlated with the quantity of decondensed chromatin. It is speculated that differentiation of the Guinea pig eye involves differential DNA synthesis, and that the extra-DNA could have some ''trigger'' function for the pattern of chromatin condensation and thus the pattern of gene expression. (author)

  19. Effects of Aging in Dry Eye

    Science.gov (United States)

    de Paiva, Cintia S.

    2017-01-01

    Dry eye affects millions of people worldwide and causes eye well recognized risk factors for dry eye. Anatomical and inflammation-induced age-related changes affect all components of the lacrimal gland functional unit, inclusive of lacrimal gland, conjunctiva, meibomian gland and compromise ocular surface health. There is increased evidence that inflammation plays a role in dry eye. This review will summarize the current knowledge about aging and dry eye, inclusive of lessons learned from animal models and promising therapies. PMID:28282314

  20. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  1. Rotational symmetric HMD with eye-tracking capability

    Science.gov (United States)

    Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian

    2016-10-01

    As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.

  2. A holographic waveguide based eye tracker

    Science.gov (United States)

    Liu, Changgeng; Pazzucconi, Beatrice; Liu, Juan; Liu, Lei; Yao, Xincheng

    2018-02-01

    We demonstrated the feasibility of using holographic waveguide for eye tracking. A custom-built holographic waveguide, a 20 mm x 60 mm x 3 mm flat glass substrate with integrated in- and out-couplers, was used for the prototype development. The in- and out-couplers, photopolymer films with holographic fringes, induced total internal reflection in the glass substrate. Diffractive optical elements were integrated into the in-coupler to serve as an optical collimator. The waveguide captured images of the anterior segment of the eye right in front of it and guided the images to a processing unit distant from the eye. The vector connecting the pupil center (PC) and the corneal reflex (CR) of the eye was used to compute eye position in the socket. An eye model, made of a high quality prosthetic eye, was used prototype validation. The benchtop prototype demonstrated a linear relationship between the angular eye position and the PC/CR vector over a range of 60 horizontal degrees and 30 vertical degrees at a resolution of 0.64-0.69 degrees/pixel by simple pixel count. The uncertainties of the measurements at different angular positions were within 1.2 pixels, which indicated that the prototype exhibited a high level of repeatability. These results confirmed that the holographic waveguide technology could be a feasible platform for developing a wearable eye tracker. Further development can lead to a compact, see-through eye tracker, which allows continuous monitoring of eye movement during real life tasks, and thus benefits diagnosis of oculomotor disorders.

  3. A Pilot Study to Improve Access to Eye Care Services for Patients in Rural India by Implementing Community Ophthalmology through Innovative Telehealth Technology.

    Science.gov (United States)

    John, Sheila; Premila, M; Javed, Mohd; Vikas, G; Wagholikar, Amol

    2015-01-01

    To inform about a very unique and first of its kind telehealth pilot study in India that has provided virtual telehealth consultation to eye care patients in low resource at remote villages. Provision of Access to eye care services in remote population is always challenging due to pragmatic reasons. Advances in Telehealth technologies have provided an opportunity to improve access to remote population. However, current Telehealth technologies are limited to face-to-face video consultation only. We inform about a pilot study that illustrates real-time imaging access to ophthalmologists. Our innovative software led technology solution allowed screening of patients with varying ocular conditions. Eye camps were conducted in 2 districts in South India over a 12-month period in 2014. Total of 196 eye camps were conducted. Total of 19,634 patients attended the eye camps. Innovative software was used to conduct consultation with the ophthalmologist located in the city hospital. The software enabled virtual visit and allowed instant sharing of fundus camera images for assessment and diagnosis. About 71% of the patients were found to have Refractive Error problems, 15% of them were found to have cataract, 7% of the patients were diagnosed to have Retina problems and 7% of the patients were found to have other ocular diseases. The patients requiring cataract surgery were immediately transferred to city hospital for treatment. Software led assessment of fundus camera images assisted in identifying retinal eye diseases. Our real-time virtual visit software assisted in specialist care provision and illustrated a novel tele health solution for low resource population.

  4. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  5. Shaping the Electronic Library--The UW-Madison Approach.

    Science.gov (United States)

    Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David

    1998-01-01

    This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…

  6. EVALUATION OF DRY EYES IN DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Anshu Sharma

    2017-12-01

    Full Text Available BACKGROUND According to the National Eye Institute, dry eye is a condition in which the eye does not produce tears properly. It can also involve tears not having the right consistency or evaporating too quickly. Tears are necessary to help maintain moisture on the surface of the eye and for clear vision. Diabetes is often associated with several significant ocular conditions such as retinopathy, refractive changes, cataracts, glaucoma and macular oedema. However, one of the most common ocular complications associated with diabetes is dry eye. The aim of the study is to study the prevalence of dry eyes in diabetes mellitus and to evaluate ocular and other risk factors relevant to diabetic dry eyes. MATERIALS AND METHODS A hospital-based cross-sectional clinical study of 100 diabetic patients who presented to the Department of Ophthalmology, Santosh Medical College and Hospital, Ghaziabad, between January 2016 to June 2017 was conducted. Detailed diabetic history was recorded. Assessment of anterior segment via slit-lamp biomicroscopy was done. The examinations for dry eyes included Schirmer's test, tear breakup time, fluorescein and rose Bengal staining. RESULTS Sixty two (62% diabetic patients had dry eye. The prevalence in type I was 3% and prevalence in type II was 59%. Dry eye prevalence was maximum in those above 40 years of age. Symptoms like reduced corneal sensation (44% and meibomitis (20% were major attributable risk factors. Ocular surface damage was predominantly superficial punctate keratitis. Retinopathy was not statistically associated with the prevalence of dry eyes. CONCLUSION Diabetes and dry eye appears to be a common association. Reduction in the modifiable risk factors of dry eye is essential to reduce its prevalence. No significant statistical correlation was found between retinopathy and dry eyes. However, examination for dry eyes should be an integral part of the assessment of diabetic eye disease.

  7. Impact of dry eye on work productivity

    Directory of Open Access Journals (Sweden)

    Yamada M

    2012-10-01

    Full Text Available Masakazu Yamada, Yoshinobu Mizuno, Chika ShigeyasuNational Institute of Sensory Organs, National Hospital Organization Tokyo Medical Center, Tokyo, JapanBackground: The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism.Methods: A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed.Results: The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P < 0.05. The annual cost of work productivity loss associated with dry eye was estimated to be USD 741 per person.Conclusion: Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.Keywords: burden of disease, dry eye, presenteeism, quality of life

  8. Molecular mechanism of ocular surface damage: application to an in vitro dry eye model on human corneal epithelium.

    Science.gov (United States)

    Meloni, Marisa; De Servi, Barbara; Marasco, Daniela; Del Prete, Salvatore

    2011-01-12

    The present study was concerned with the development of a new experimental model of dry eye using human reconstructed in vitro corneal epithelium (HCE). The model is based on the use of adapted culture conditions that induce relevant modifications at the cellular and molecular level thus mimicking dry eye. The HCE model was maintained in a controlled environmental setting (relative humidity eye. The evolution of the dry eye condition was assessed by histology, immunohistochemistry staining, scanning electron microscopy, and gene expression by using TaqMan gene assay technology (mucin-4 [MUC4], matrix metallopeptidase-9 [MMP9], tumor necrosis factor-α [TNF-α], and defensin β-2 [DEFB2). The effects of different commercially available tear substitutes on the induced dry eye condition were tested. This in vitro dry eye HCE model, that was well established within 24 h, has the characteristic features of a dry eye epithelium and could be satisfactorily used for preliminary assessment of the protective activity of some artificial tears. The transcriptional study of selected biomarkers showed an increase in MUC4, MMP9, TNF-α, and hBD-2 (DEFB2) gene expression. By using a dynamic approach, we were able to define a biomarker gene signature of dry eye-induced effects that could be predictive of corneal damage in vivo and to discriminate the efficacy among different commercial artificial tears.

  9. Over the counter (OTC) artificial tear drops for dry eye syndrome

    Science.gov (United States)

    Pucker, Andrew D; Ng, Sueko M; Nichols, Jason J

    2016-01-01

    Background Over the counter (OTC) artificial tears historically have been the first line of treatment for dry eye syndrome and dry eye-related conditions like contact lens discomfort, yet currently we know little regarding the overall efficacy of individual, commercially available artificial tears. This review provides a much needed meta-analytical look at all randomized and quasi-randomized clinical trials that have analyzed head-to-head comparisons of OTC artificial tears. Objectives To evaluate the effectiveness and toxicity of OTC artificial tear applications in the treatment of dry eye syndrome compared with another class of OTC artificial tears, no treatment, or placebo. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2015, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2015), EMBASE (January 1980 to December 2015), Latin American and Caribbean Health Sciences (LILACS) (January 1982 to December 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the US Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 4 December 2015. We searched reference lists of included trials for any additional trials not identified by the electronic searches. Selection criteria This review includes randomized controlled trials with adult participants who were diagnosed with dry eye, regardless of race and gender. We included trials in which the age of participants was not reported, and clinical trials comparing OTC artificial tears with another class of OTC artificial tears, placebo, or no treatment. This review did not

  10. Eye/head tracking technology to improve HCI with iPad applications.

    Science.gov (United States)

    Lopez-Basterretxea, Asier; Mendez-Zorrilla, Amaia; Garcia-Zapirain, Begoña

    2015-01-22

    In order to improve human computer interaction (HCI) for people with special needs, this paper presents an alternative form of interaction, which uses the iPad's front camera and eye/head tracking technology. With this functional nature/capability operating in the background, the user can control already developed or new applications for the iPad by moving their eyes and/or head. There are many techniques, which are currently used to detect facial features, such as eyes or even the face itself. Open source bookstores exist for such purpose, such as OpenCV, which enable very reliable and accurate detection algorithms to be applied, such as Haar Cascade using very high-level programming. All processing is undertaken in real time, and it is therefore important to pay close attention to the use of limited resources (processing capacity) of devices, such as the iPad. The system was validated in tests involving 22 users of different ages and characteristics (people with dark and light-colored eyes and with/without glasses). These tests are performed to assess user/device interaction and to ascertain whether it works properly. The system obtained an accuracy of between 60% and 100% in the three test exercises taken into consideration. The results showed that the Haar Cascade had a significant effect by detecting faces in 100% of cases, unlike eyes and the pupil where interference (light and shade) evidenced less effectiveness. In addition to ascertaining the effectiveness of the system via these exercises, the demo application has also helped to show that user constraints need not affect the enjoyment and use of a particular type of technology. In short, the results obtained are encouraging and these systems may continue to be developed if extended and updated in the future.

  11. Eye/Head Tracking Technology to Improve HCI with iPad Applications

    Directory of Open Access Journals (Sweden)

    Asier Lopez-Basterretxea

    2015-01-01

    Full Text Available In order to improve human computer interaction (HCI for people with special needs, this paper presents an alternative form of interaction, which uses the iPad’s front camera and eye/head tracking technology. With this functional nature/capability operating in the background, the user can control already developed or new applications for the iPad by moving their eyes and/or head. There are many techniques, which are currently used to detect facial features, such as eyes or even the face itself. Open source bookstores exist for such purpose, such as OpenCV, which enable very reliable and accurate detection algorithms to be applied, such as Haar Cascade using very high-level programming. All processing is undertaken in real time, and it is therefore important to pay close attention to the use of limited resources (processing capacity of devices, such as the iPad. The system was validated in tests involving 22 users of different ages and characteristics (people with dark and light-colored eyes and with/without glasses. These tests are performed to assess user/device interaction and to ascertain whether it works properly. The system obtained an accuracy of between 60% and 100% in the three test exercises taken into consideration. The results showed that the Haar Cascade had a significant effect by detecting faces in 100% of cases, unlike eyes and the pupil where interference (light and shade evidenced less effectiveness. In addition to ascertaining the effectiveness of the system via these exercises, the demo application has also helped to show that user constraints need not affect the enjoyment and use of a particular type of technology. In short, the results obtained are encouraging and these systems may continue to be developed if extended and updated in the future.

  12. Eye Involvement in TSC

    Science.gov (United States)

    ... eye involvement. Nonretinal and Retinal Eye Findings Facial angiofibromas may involve the eyelids of individuals with TSC, ... the hamartomas have many blood vessels (as are angiofibromas of the skin). Less than half of the ...

  13. The "hypnotic state" and eye movements : Less there than meets the eye?

    NARCIS (Netherlands)

    Cardea, Etzel; Nordhjem, Barbara; Marcusson-Clavertz, David; Holmqvist, Kenneth

    2017-01-01

    Responsiveness to hypnotic procedures has been related to unusual eye behaviors for centuries. Kallio and collaborators claimed recently that they had found a reliable index for "the hypnotic state" through eye-tracking methods. Whether or not hypnotic responding involves a special state of

  14. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  15. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  16. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Science.gov (United States)

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  17. Patterning of a compound eye on an extinct dipteran wing.

    Science.gov (United States)

    Dinwiddie, April; Rachootin, Stan

    2011-04-23

    We have discovered unexpected similarities between a novel and characteristic wing organ in an extinct biting midge from Baltic amber, Eohelea petrunkevitchi, and the surface of a dipteran's compound eye. Scanning electron microscope images now reveal vestigial mechanoreceptors between the facets of the organ. We interpret Eohelea's wing organ as the blending of these two developmental systems: the formation and patterning of the cuticle in the eye and of the wing. Typically, only females in the genus carry this distinctive, highly organized structure. Two species were studied (E. petrunkevitchi and E. sinuosa), and the structure differs in form between them. We examine Eohelea's wing structures for modes of fabrication, material properties and biological functions, and the effective ecological environment in which these midges lived. We argue that the current view of the wing organ's function in stridulation has been misconstrued since it was described half a century ago.

  18. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and ...

  20. Eye dosimetry and protective eye wear for interventional clinicians

    International Nuclear Information System (INIS)

    Martin, C.J.; Magee, J.S.; Sandblom; Almen, A.; Lundh, C.

    2015-01-01

    Doses to the eyes of interventional clinicians can exceed 20 mSv. Various protective devices can afford protection to the eyes with the final barrier being protective eye wear. The protection provided by lead glasses is difficult to quantify, and the majority of dosimeters are not designed to be worn under lead glasses. This study has measured dose reduction factors (DRFs) equal to the ratio of the dose with no protection, divided by that when lead glasses are worn. Glasses have been tested in X-ray fields using anthropomorphic phantoms to simulate the patient and clinician. DRFs for X-rays incident from the front vary from 5.2 to 7.6, while values for orientations reminiscent of clinical practice are between 1.4 and 5.2. Results suggest that a DRF of two is a conservative factor that could be applied to personal dosimeter measurements to account for the dose reduction provided by most types of lead glasses. (authors)

  1. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Directory of Open Access Journals (Sweden)

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  2. Airbag deployment-related eye injuries.

    Science.gov (United States)

    Koisaari, Tapio; Leivo, Tiina; Sahraravand, Ahmad; Haavisto, Anna-Kaisa; Sulander, Pekka; Tervo, Timo M T

    2017-07-04

    We studied the correlation between airbag deployment and eye injuries using 2 different data sets. The registry of the Finnish Road Accident (FRA) Investigation Teams was analyzed to study severe head- and eyewear-related injuries. All fatal passenger car or van accidents that occurred during the years 2009-2012 (4 years) were included (n = 734). Cases in which the driver's front airbag was deployed were subjected to analysis (n = 409). To determine the proportion of minor, potentially airbag-related eye injuries, the results were compared to the data for all new eye injury patients (n = 1,151) recorded at the Emergency Clinic of the Helsinki University Eye Hospital (HUEH) during one year, from May 1, 2011, to April 30, 2012. In the FRA data set, the unbelted drivers showed a significantly higher risk of death (odds ratio [OR] = 5.89, 95% confidence interval [CI], 3.33-10.9, P = 2.6E-12) or of sustaining head injuries (OR = 2.50, 95% CI, 1.59-3.97, P = 3.8E-5). Only 4 of the 1,151 HUEH patients were involved in a passenger car accident. In one of the crashes, the airbag operated, and the belted driver received 2 sutured eye lid wounds and showed conjunctival sugillation. No permanent eye injuries were recorded during the follow-up. The calculated annual airbag-related eye injury incidence was less than 1/1,000,000 people, 4/100,000 accidents, and 4/10,000 injured occupants. Airbag-related eye injuries occurred very rarely in car accidents in cases where the occupant survived and the restraint system was appropriately used. Spectacle use did not appear to increase the risk of eye injury in restrained occupants.

  3. Management of digital eye strain.

    Science.gov (United States)

    Coles-Brennan, Chantal; Sulley, Anna; Young, Graeme

    2018-05-23

    Digital eye strain, an emerging public health issue, is a condition characterised by visual disturbance and/or ocular discomfort related to the use of digital devices and resulting from a range of stresses on the ocular environment. This review aims to provide an overview of the extensive literature on digital eye strain research with particular reference to the clinical management of symptoms. As many as 90 per cent of digital device users experience symptoms of digital eye strain. Many studies suggest that the following factors are associated with digital eye strain: uncorrected refractive error (including presbyopia), accommodative and vergence anomalies, altered blinking pattern (reduced rate and incomplete blinking), excessive exposure to intense light, closer working distance, and smaller font size. Since a symptom may be caused by one or more factors, a holistic approach should be adopted. The following management strategies have been suggested: (i) appropriate correction of refractive error, including astigmatism and presbyopia; (ii) management of vergence anomalies, with the aim of inducing or leaving a small amount of heterophoria (~1.5 Δ Exo); (iii) blinking exercise/training to maintain normal blinking pattern; (iv) use of lubricating eye drops (artificial tears) to help alleviate dry eye-related symptoms; (v) contact lenses with enhanced comfort, particularly at end-of-day and in challenging environments; (vi) prescription of colour filters in all vision correction options, especially blue light-absorbing filters; and (vii) management of accommodative anomalies. Prevention is the main strategy for management of digital eye strain, which involves: (i) ensuring an ergonomic work environment and practice (through patient education and the implementation of ergonomic workplace policies); and (ii) visual examination and eye care to treat visual disorders. Special consideration is needed for people at a high risk of digital eye strain, such as computer

  4. Survey of eye practitioners' preference of diagnostic tests and treatment modalities for dry eye in Ghana.

    Science.gov (United States)

    Asiedu, Kofi; Kyei, Samuel; Ayobi, Benedict; Agyemang, Frank Okyere; Ablordeppey, Reynolds Kwame

    2016-12-01

    This study sought to provide an evidence-based profile of the diagnosis, treatment and knowledge or opinions on dry eye among optometrists and ophthalmologists in Ghana. This was a cross-sectional survey RESULTS: The responses of 162 participants are included in the analysis. The most commonly used test to diagnosed dry eye disease was tear break-up time followed by patient history. The most common symptom doctors heard from dry eye patients were burning sensation followed by foreign body sensation. The most often prescribed first- line treatment for dry eye was aqueous-based artificial tears followed by lipid-based artificial tears. Most practitioners considered meibomian gland dysfunction as the most common cause of dry eye followed by pterygium. The most often used test to guide or gauge therapeutic effect is patient history followed closely by tear break-up time. Most practitioners reported that 10%-20% of all their patients they see in a day are diagnosed of dry eye. This study showed tear break up time was the main test majority of practitioners in Ghana used to diagnose dry eye but patient history was the main test used to gauge therapeutic effect over time. Burning sensation was the commonest symptom practitioners heard from dry eye patients whilst artificial tears was their main and first-line treatment for dry eye. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Electronic resources access and usage among the postgraduates of ...

    African Journals Online (AJOL)

    ... and usage among the postgraduates of a Nigerian University of Technology. ... faced by postgraduates in using e-resources include takes too much time to find, ... Resources, Access, Use, Postgraduat, Students, University, Technology, Nigeria ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... seasonal allergens and dry eye Apr 27, 2015 Choosing Wisely When It Comes to Eye Care, Part ... Name: Member ID: * Phone Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  7. Aquaporins in the Eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Hamann, Steffen; Heegaard, Steffen

    2017-01-01

    The major part of the eye consists of water . Continuous movement of water and ions between the ocular compartments and to the systemic circulation is pivotal for many physiological functions in the eye. The movement of water facilitates removal of the many metabolic products of corneal-, ciliary...... pressure. In the retina, water is transported into the vitreous body and across the retinal pigment epithelium to regulate the extracellular environment and the hydration of the retina. Aquaporins (AQPs ) take part in the water transport throughout the eye....

  8. Crop Type Classification Using Vegetation Indices of RapidEye Imagery

    Science.gov (United States)

    Ustuner, M.; Sanli, F. B.; Abdikan, S.; Esetlili, M. T.; Kurucu, Y.

    2014-09-01

    Cutting-edge remote sensing technology has a significant role for managing the natural resources as well as the any other applications about the earth observation. Crop monitoring is the one of these applications since remote sensing provides us accurate, up-to-date and cost-effective information about the crop types at the different temporal and spatial resolution. In this study, the potential use of three different vegetation indices of RapidEye imagery on crop type classification as well as the effect of each indices on classification accuracy were investigated. The Normalized Difference Vegetation Index (NDVI), the Green Normalized Difference Vegetation Index (GNDVI), and the Normalized Difference Red Edge Index (NDRE) are the three vegetation indices used in this study since all of these incorporated the near-infrared (NIR) band. RapidEye imagery is highly demanded and preferred for agricultural and forestry applications since it has red-edge and NIR bands. The study area is located in Aegean region of Turkey. Radial Basis Function (RBF) kernel was used here for the Support Vector Machines (SVMs) classification. Original bands of RapidEye imagery were excluded and classification was performed with only three vegetation indices. The contribution of each indices on image classification accuracy was also tested with single band classification. Highest classification accuracy of 87, 46 % was obtained using three vegetation indices. This obtained classification accuracy is higher than the classification accuracy of any dual-combination of these vegetation indices. Results demonstrate that NDRE has the highest contribution on classification accuracy compared to the other vegetation indices and the RapidEye imagery can get satisfactory results of classification accuracy without original bands.

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... right type of tears or tear film . How do tears work? When you blink, a film of ... layer cleans the eye, washing away particles that do not belong in the eye. This layer comes ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Kierstan Boyd Reviewed By: Brenda Pagan-Duran MD Sep. 01, 2017 Our eyes need tears to stay ... tear duct to insert a permanent punctal plug? Sep 12, 2017 Why are my eyes bloodshot when ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... removed or pushed down the tear duct to insert a permanent punctal plug? Sep 12, 2017 Why ... Eye from Jennifer Aniston Sep 02, 2016 The link between seasonal allergens and dry eye Apr 27, ...

  12. Lasik eye surgery - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100206.htm Lasik eye surgery - series—Normal anatomy To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Laser Eye Surgery A.D.A.M., Inc. is accredited by ...

  13. Fluid Mixing in the Eye Under Rapid Eye Movement

    Science.gov (United States)

    Huang, Jinglin; Gharib, Morteza

    2017-11-01

    Drug injection is an important technique in certain treatments of eye diseases. The efficacy of chemical mixing plays an important role in determining pharmacokinetics of injected drugs. In this study, we build a device to study the chemical mixing behavior in a spherical structure. The mixing process is visualized and analyzed qualitatively. We hope to understand the chemical convection and diffusion behaviors in correlation with controlled rapid mechanical movements. The results will have potential applications in treatment of eye diseases. Resnick Institute at Caltech.

  14. Exploring the Predisposition of the Asian Eye to Development of Dry Eye.

    Science.gov (United States)

    Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min

    2016-07-01

    To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all Pdry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all Pdry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Quality indicators for eye bank.

    Science.gov (United States)

    Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta

    2018-03-01

    The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  16. Intermediate view synthesis for eye-gazing

    Science.gov (United States)

    Baek, Eu-Ttuem; Ho, Yo-Sung

    2015-01-01

    Nonverbal communication, also known as body language, is an important form of communication. Nonverbal behaviors such as posture, eye contact, and gestures send strong messages. In regard to nonverbal communication, eye contact is one of the most important forms that an individual can use. However, lack of eye contact occurs when we use video conferencing system. The disparity between locations of the eyes and a camera gets in the way of eye contact. The lock of eye gazing can give unapproachable and unpleasant feeling. In this paper, we proposed an eye gazing correction for video conferencing. We use two cameras installed at the top and the bottom of the television. The captured two images are rendered with 2D warping at virtual position. We implement view morphing to the detected face, and synthesize the face and the warped image. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.

  17. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model.

    Science.gov (United States)

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9(th) postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue.

  18. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  19. Smoking and Eye Health

    Science.gov (United States)

    ... Patient Stories Español Eye Health / Tips & Prevention Sections Smoking and Eye Disease Leer en Español: El cigarrillo ... By: Brenda Pagan-Duran MD Apr. 27, 2017 Smoking contributes to a number of major health problems, ...

  20. Keep An Eye Out For Myasthenia Gravis Patients With An Eye Out

    Directory of Open Access Journals (Sweden)

    A Arturo eLeis

    2014-07-01

    Full Text Available Eye trauma and blindness are common in the United States, with an incidence of over 2 million cases per year and 25 million blind adults, respectively. However, literature is surprisingly scarce on the potential confounding effect of eye trauma or blindness on the diagnosis of myasthenia gravis (MG, an autoimmune neuromuscular disease in which fluctuating ocular symptoms are the most distinguishing feature. We present the case of a 75 year-old man with eye enucleation referred for electrodiagnostic evaluation of the right upper limb after an accidental fall. Neurological examination showed proximal muscle weakness, but MG was not initially considered because the patient lacked the classic ocular symptoms of MG. The delay in diagnosis resulted in worsening of systemic MG symptoms, although in other patients it may have precipitated MG crisis or possibly death. Greater awareness that eye trauma or blindness can prevent expression of ocular symptoms in neuromuscular disorders is needed to avoid morbidity associated with an erroneous or delayed diagnosis.

  1. Dynamic shifts of limited working memory resources in human vision.

    Science.gov (United States)

    Bays, Paul M; Husain, Masud

    2008-08-08

    Our ability to remember what we have seen is very limited. Most current views characterize this limit as a fixed number of items-only four objects-that can be held in visual working memory. We show that visual memory capacity is not fixed by the number of objects, but rather is a limited resource that is shared out dynamically between all items in the visual scene. This resource can be shifted flexibly between objects, with allocation biased by selective attention and toward targets of upcoming eye movements. The proportion of resources allocated to each item determines the precision with which it is remembered, a relation that we show is governed by a simple power law, allowing quantitative estimates of resource distribution in a scene.

  2. Beneficial effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea.

    Science.gov (United States)

    Xiao, Fan; Cui, Hua; Zhong, Xiao

    2018-05-01

    Present investigation evaluates the effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea. Briefly, electron spine resonance was used for the estimation of radical scavenging activity of daidzin and COX Fluorescent Activity Assay Kit was used for the estimation of PGS activity. Dry eye rat model was developed by removing the lacrimal gland and effect of daidzin was evaluated in dry eye rat model by estimating the fluorescein score, tear volume and expressions of heme oxigenase (HO-1), TNF α, Interlukin 6 (IL-6), matrix metallopeptidase 9 (MMP-9) and PGS-2. Result of the present study suggested that daidzin possess tyrosyl radical scavenging activity and thereby decreases the oxidative stress. Activity of PGS significantly increases in dry eye which was inhibited by daidzin treatment due to competitive inhibition of PGS. It also recovers the tear volume in dry eye rat model in which lacrimal gland was removed. Thus corneal erosion was improved by daidzin in dry eye rat model. Thus present study concludes that treatment with daidzin protects the cornea in dry eye rat model by suppression inflammation and oxidative stress.

  3. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ...

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ...

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ...

  13. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  14. Beneficial effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea

    Directory of Open Access Journals (Sweden)

    Fan Xiao

    2018-05-01

    Full Text Available Present investigation evaluates the effect of daidzin in dry eye rat model through the suppression of inflammation and oxidative stress in the cornea. Briefly, electron spine resonance was used for the estimation of radical scavenging activity of daidzin and COX Fluorescent Activity Assay Kit was used for the estimation of PGS activity. Dry eye rat model was developed by removing the lacrimal gland and effect of daidzin was evaluated in dry eye rat model by estimating the fluorescein score, tear volume and expressions of heme oxigenase (HO-1, TNF α, Interlukin 6 (IL-6, matrix metallopeptidase 9 (MMP-9 and PGS-2. Result of the present study suggested that daidzin possess tyrosyl radical scavenging activity and thereby decreases the oxidative stress. Activity of PGS significantly increases in dry eye which was inhibited by daidzin treatment due to competitive inhibition of PGS. It also recovers the tear volume in dry eye rat model in which lacrimal gland was removed. Thus corneal erosion was improved by daidzin in dry eye rat model. Thus present study concludes that treatment with daidzin protects the cornea in dry eye rat model by suppression inflammation and oxidative stress. Keywords: Daidzin, Dry eye, Radical scavenging activity, Inflammation

  15. MEMS scanner mirror based system for retina scanning and in eye projection

    Science.gov (United States)

    Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich

    2015-02-01

    Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.

  16. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  17. An Evaluation of a Human Machine Interface based on Attentional-resources Effectiveness

    International Nuclear Information System (INIS)

    Ha, Jun Su; Seong, Poong Hyun

    2008-01-01

    Measures of attentional-resource effectiveness during monitoring and detection tasks in nuclear power plants (NPPs) have been developed based on cost-benefit principle and validated with experimental studies. The underlying principle of the measures is that information sources should be selectively attended according to their informational importance. One of two measures is Fixation to Importance Ratio (FIR) which represents attentional-resources (eye fixations) spent on an information source compared to importance of the information source

  18. Interim report of the JHPS expert committee on radiation protection of the lens of the eye (4). Current activities of ICRP and ICU: External dosimetric concepts for the lens of the eye

    International Nuclear Information System (INIS)

    Akahane, Keiichi; Tatsuzaki, Hideo; Iimoto, Takeshi; Ichiji, Takeshi; Hamada, Nobuyuki; Fujimichi, Yuki; Iwai, Satoshi; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi-Kawaura, Chiyo; Tsujimura, Norio; Hotta, Yutaka; Yamasaki, Tadashi; Yokoyama, Sumi

    2015-01-01

    The International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU) have been defined operational quantities and protection quantities. Dose limits have been also recommended by the ICRP using protection quantities. These quantities and some related values for main radiation such as photons, electrons, and neutrons, are summarized in this article with some historical considerations. The ICRP indicated conversion coefficients for the lens of the eye as absorbed dose per fluence as protection quantities. equivalent dose is not used because a protection quantity that uses radiation weighting factors is not intended to be calculated for tissue reactions. So far, the ICRP has not indicated a specific RBE value for cataract formation. Operational quantities are used for measurements. There have been three types of phantoms, namely a slab phantom, a reduced phantom, and a cylindrical phantom, but none of them has been definitely recommended for the lens of the eye by the ICRP or the ICRU. Although conversion coefficients to personal dose equivalent, H p (3), for electrons have been recommended, no other conversion coefficients to personal dose equivalent for the lens of the eye has been indicated by the ICRP or the ICRU. However, there have been several studies described personal dose equivalent. Ambient dose equivalent, H * (3), and directional dose equivalent, H(3, α), have been indicated in several limited conditions by the ICRP and the ICRU. These status are overviewed in this article. (author)

  19. EFFECTIVE ELECTRONIC TUTORIAL

    Directory of Open Access Journals (Sweden)

    Andrei A. Fedoseev

    2014-01-01

    Full Text Available The article analyzes effective electronic tutorials creation and application based on the theory of pedagogy. Herewith the issues of necessary electronic tutorial functional, ways of the educational process organization with the use of information and communication technologies and the logistics of electronic educational resources are touched upon. 

  20. Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.

    Science.gov (United States)

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-07-15

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions.

  1. Comparison of postoperative corneal changes between dry eye and non-dry eye in a murine cataract surgery model

    Science.gov (United States)

    Kwon, Jin Woo; Chung, Yeon Woong; Choi, Jin A; La, Tae Yoon; Jee, Dong Hyun; Cho, Yang Kyung

    2016-01-01

    AIM To compare the effects of the surgical insult of cataract surgery on corneal inflammatory infiltration, neovascularization (NV) and lymphangiogenesis (LY) between the dry eye and non-dry eye in murine cataract surgery models. METHODS We established two groups of animals, one with normal eyes (non-dry eye) and the second with induced dry eyes. In both groups, we used surgical insults to mimic human cataract surgery, which consisted of lens extraction, corneal incision and suture. After harvesting of corneas on the 9th postoperative day and immunohistochemical staining, we compared NV, LY and CD11b+ cell infiltration in the corneas. RESULTS Dry eye group had significantly more inflammatory infiltration (21.75%±7.17% vs 3.65%±1.49%; P=0.049). The dry eye group showed significantly more NV (48.21%±4.02% vs 26.24%±6.01%; P=0.016) and greater levels of LY (9.27%±0.48% vs 4.84%±1.15%; P=0.007). In corneas on which no surgery was performed, there was no induction of NV in both the dry and non-dry group, but dry eye group demonstrated more CD11b+ cells infiltration than the non-dry eye group (0.360%±0.160% vs 0.023%±0.006%; P=0.068). Dry eye group showed more NV than non-dry eye group in both topical PBS application and subconjunctival PBS injection (P=0.020 and 0.000, respectively). CONCLUSION In a murine cataract surgery model, preexisting dry eye can induce more postoperative NV, LY, and inflammation in corneal tissue. PMID:26949638

  2. Eye retraction in the giant guitarfish, Rhynchobatus djiddensis (Elasmobranchii: Batoidea): a novel mechanism for eye protection in batoid fishes.

    Science.gov (United States)

    Tomita, Taketeru; Murakumo, Kiyomi; Miyamoto, Kei; Sato, Keiichi; Oka, Shin-ichiro; Kamisako, Haruka; Toda, Minoru

    2016-02-01

    Eye retraction behavior has evolved independently in some vertebrate linages such as mudskippers (fish), frogs and salamanders (amphibians), and cetaceans (mammals). In this paper, we report the eye retraction behavior of the giant guitarfish (Rhynchobatus djiddensis) for the first time, and discuss its mechanism and function. The eye retraction distance was nearly the same as the diameter of the eyeball itself, indicating that eye retraction in the giant guitarfish is probably one of the largest among vertebrates. Eye retraction is achieved by unique arrangement of the eye muscle: one of the anterior eye muscles (the obliquus inferior) is directed ventrally from the eyeball and attaches to the ventral surface of the neurocranium. Due to such muscle arrangement, the obliquus inferior can pull the eyeball ventrally. This mechanism was also confirmed by electrical stimulation of the obliquus inferior. The eye retraction ability of the giant guitarfish likely represents a novel eye protection behavior of elasmobranch fishes. Copyright © 2015 Elsevier GmbH. All rights reserved.

  3. Sun, UV Radiation and Your Eyes

    Science.gov (United States)

    ... Sunglasses Sun Smart UV Safety Infographic The Sun, UV Radiation and Your Eyes Leer en Español: El ... Aug. 28, 2014 Keep an Eye on Ultraviolet (UV) Safety Eye medical doctors (ophthalmologists) caution us that ...

  4. Quality indicators for eye bank

    Directory of Open Access Journals (Sweden)

    Manisha Acharya

    2018-01-01

    Full Text Available Purpose: The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Methods: Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions – “result quality” and “process quality.” The indicators were measured and tracked as part of quality assurance (QA program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011–2016. Results: Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%, discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. Conclusion: These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  5. Functional magnetic resonance imaging of the frontal eye fields during saccadic eye movements

    International Nuclear Information System (INIS)

    Miki, Atsushi; Takagi, Mineo; Abe, Haruki; Nakajima, Takashi; Miyauchi, Satoru.

    1996-01-01

    We evaluated activity-induced signal intensity changes in the human cerebral cortex during horizontal saccadic eye movements using functional magnetic resonance imaging (fMRI) based on the blood-oxygenation-level-dependent (BOLD) contrast method. Compared with central fixation, significant signal increases were observed bilaterally in the middle frontal gyrus (Brodmann area 8) during saccadic conditions. The location of the activated area was consistent with that of previously reported frontal eye fields (FEF). These results suggest that fMRI has potential merit for the study of cortical control of eye movements in humans. (author)

  6. Imaging of osteo-odonto-keratoprosthesis by electron beam tomography

    OpenAIRE

    Fong, K C S; Ferrett, C G; Tandon, R; Paul, B; Herold, J; Liu, C S C

    2005-01-01

    Aim: To describe the experience of using electron beam tomography (EBT) in imaging of osteo-odonto-keratoprosthesis (OOKP) to identify early bone and dentine loss which may threaten the viability of the eye.

  7. Eye safe laser range finders

    International Nuclear Information System (INIS)

    Snir, M.; Margaliot, M.; Amitzi, A.

    2004-01-01

    During the 1970's, Ruby (Q switched) laser based range finders with a wavelength of 694nm were first used. These lasers operated in a pulse mode within the visible light range and produced a risk for the eye retina. The laser beam striking the macula could damage the eye and might cause blindness. Over the years, Nd:YAG (Q switched) lasers were developed (operating at 1064nm) for range finding and designation uses. The wavelength of these lasers, operating in the near Infra-Red range (invisible), is also focused tightly on the retina. The human eye does not respond to the invisible light so there is no natural protection (eye blink reflex) as in the visible light. The operation of these lasers worldwide, especially when the laser beam is exposed, causes occasional eye accidents. Another risk is stemming from the use of observation systems with a high optical gain, in the laser operation areas, which enlarge the range of risk quite significantly. Therefore, research and development efforts were invested in order to introduce eye safe lasers. One of the solutions for this problem is presented in following document

  8. Dry eyes: etiology and management.

    Science.gov (United States)

    Latkany, Robert

    2008-07-01

    Until recently, the cause of dry eye syndrome was uncertain and the treatment was palliative. Since discovering that dry eyes are caused by inflammation, there has been an abundance of research focusing on anti-inflammatory therapies, other contributing causes, and better diagnostic testing. This review summarizes some of the interesting published research on ocular surface disease over the past year. The definition of dry eye now highlights the omnipresent symptom of blurry vision. The re-evaluation of ocular surface staining, tear meniscus height, and visual change will allow for a better diagnosis and understanding of dry eyes. Punctal plugs, and oral and topical anti-inflammatory use will strengthen our arsenal against ocular surface disease. Major progress has occurred in the past few years in gaining a better understanding of the etiology of dry eye syndrome, which will inevitably lead to more effective therapeutic options.

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... is also when your eyes do not make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... bloodshot when I wake up? Jun 26, 2016 Why are my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes when I sleep? Feb 10, 2016 Can light sensitivity from Parkinson’s ...

  11. [Observation on therapeutic effect of dry eye syndrome treated with acupuncture on the acupoints around the eyes].

    Science.gov (United States)

    Gao, Wei-Ping; Liu, Min; Zhang, Yi-Biao

    2010-06-01

    To observed the clinical efficacy on dry eye syndrome treated with acupuncture on the acupoints around the eyes. Fifty-six cases of dry eye syndrome were divided into two groups, acupuncture group and western medicine group, 28 cases in each one. In acupuncture group, acupuncture was applied to Jingming (BL 1), Cuanzhu (BL 2), Sizhukong (TE 23), Tongziliao (GB 1), etc. In western medicine group, the topical artificial tear eye drops were administered. The corneal fluorescein staining, breaking-up time (BUT), tear volume and the symptom score were observed before and after treatment in two groups. In comparison before and after treatment in acupuncture group, the statistical significant difference presented in BUT, tear volume and the symptom score (all P eyes achieves a quite good efficacy on dry eye syndrome.

  12. Face perception in the mind's eye.

    Science.gov (United States)

    Righart, Ruthger; Burra, Nicolas; Vuilleumier, Patrik

    2011-03-01

    Perceptual filling-in occurs when visual stimuli are recognized in impoverished viewing conditions. Whether missing information is filled-in during face perception and which stages might be involved in this process are still unresolved questions. Because an identity can be brought to mind by seeing eyes only, we hypothesized that missing information might be filled-in from a memory trace for the whole face identity. We presented participants with faces in phase 1 and later we presented eyes-only in phase 2. For some of these eyes in phase 2, the whole face had been presented in the previous phase, for others identical eyes had been presented. Event-related potentials (ERPs) revealed an N170 component that was more negative when eyes were preceded by a whole face in the previous phase compared to eyes preceded by identical eyes-only. A more positive-going late positive complex (LPC) was also found, suggesting enhanced retrieval of face memory representations when eyes were preceded by whole faces. Our results show that pre-existing representations of face identity can influence early stages of visual encoding, 170 ms after stimulus onset. These effects may reflect top-down modulation by memory on visual recognition processes by filling-in the missing facial information.

  13. Effects of PUVA on the eye

    International Nuclear Information System (INIS)

    Backman, H.A.

    1982-01-01

    Psoriasis is a common skin disease which may be treated with 8-methoxy psoralen and long-wave ultraviolet light (PUVA). Eye protection is provided during and after treatment to prevent the development of photokeratitis and cataracts. Fifteen patients, treated with medication and ultraviolet A (UVA) had an initial complete eye examination and a repeat examination after each treatment. No patients developed cataracts but almost one-half of the patients had a mild form of photokeratoconjunctivitis. The ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye ocular manifestations included photophobia, conjunctivitis, keratitis, and dry eyes. Tear break-up time was reduced significantly immediately after treatment for two patients but returned to normal 8 hr later. Dermatologists who employ PUVA treatments should be concerned about photokeratoconjunctivitis and the dry-eye syndrome

  14. Modelling human eye under blast loading.

    Science.gov (United States)

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues.

  15. Should Geography Educators Adopt Electronic Textbooks?

    Science.gov (United States)

    Romig, Kevin

    2017-01-01

    Significant changes in textbook publishing are at college instructors' door. Textbook representatives are directed to mesmerize potential clients with eye-catching displays and statements about digital literacy of the next generation of college students. Based on a one-year pilot study, in 2014-2015, of an electronic textbook, this commentary…

  16. Vergence-mediated changes in the axis of eye rotation during the human vestibulo-ocular reflex can occur independent of eye position.

    Science.gov (United States)

    Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J

    2003-07-01

    The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing

  17. Research on Eye Movement Tracking in ESL Reading

    Directory of Open Access Journals (Sweden)

    Wenlian ZHAN

    2014-06-01

    Full Text Available Eye movement behavior in reading can reflect on-line cognitive process. Through the on-line measure of eye movement, under relatively natural reading condition, data of the reader’ s eye movement in the text can be obtained in processing information, and thus help to reveal the internal cognitive mechanisms in reading. With the development of intelligentization, serialization and portable direction in eye tracker, there exist great number of studies on eye movement tracking, but studies on eye movement features in ESL reading are rare. In such circumstances, this paper mainly illustrates eye movement patterns, the relationship between eye movement and perceptual processing, and eye movement control in ESL reading.

  18. EyeAR: Refocusable Augmented Reality Content through Eye Measurements

    Directory of Open Access Journals (Sweden)

    Damien Constantine Rompapas

    2017-09-01

    Full Text Available Augmented Reality (AR superimposes computer graphics (CG onto a user’s view of the real world. A key quality problem in this field is to achieve coherence between reality and CG when the user’s eyes refocus or change pupil size. We designed and evaluated a display that improves coherence by measuring the user’s eye state and continuously adapting CG accordingly. Our tabletop prototype emulates an Optical See-Through Head-Mounted Display, a common AR display device. In our evaluation, participants observed three pillars at different depths. We then challenged them to identify a virtual pillar among the three while freely refocusing their eyes. Results show that our design significantly improved realism. Compared to Light Field Displays, our design aims to simplify display-optics while providing similar quality. We could only partially achieve this goal. We discuss the lessons we learned and how we plan to overcome the remaining challenges. The experimental protocol from our evaluation is useful for display developers as it can be used to measure the coherence of a display.

  19. XI. THE WATERING EYE

    African Journals Online (AJOL)

    cause a watering eye; this condition is.called epiphora. Clearly, then, in investigating ... blockage is a common disease in the middle age-groups seen in hospital .... a dry eye, and this is so much worse than a wet one that the procedure is only ...

  20. Eye tracking social preferences

    NARCIS (Netherlands)

    Jiang, Ting; Potters, Jan; Funaki, Yukihiko

    We hypothesize that if people are motivated by a particular social preference, then choosing in accordance with this preference will lead to an identifiable pattern of eye movements. We track eye movements while subjects make choices in simple three-person distribution experiments. We characterize

  1. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2015-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  2. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2014-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  3. When to Have an Eye Exam

    Science.gov (United States)

    ... from your doctor If you're seeing a new eye doctor or if you're having your first ... over your eye. This helps reveal any damaged cells on the front of your eye. Your tears wash the dye from the surface ...

  4. Fish eye optics

    Czech Academy of Sciences Publication Activity Database

    Hudec, René; Michalová, S.

    2017-01-01

    Roč. 47, č. 2 (2017), s. 94-99 ISSN 1335-1842. [INTEGRAL/BART Workshop /14./. Karlovy Vary, 03.04.2017-07.04.2017] Grant - others:GA ČR(CZ) GA13-33324S Institutional support: RVO:67985815 Keywords : fish eye optics * lobster eye optics * X-ray monitoring Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 0.336, year: 2016

  5. Bright luminance from silicon dioxide film with carbon nanotube electron beam exposure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Woong; Hong, Ji Hwan; Kang, Jung Su; Callixte, Shikili; Park, Kyu Chang, E-mail: kyupark@khu.ac.kr

    2016-02-15

    We observed the bright bluish-white luminescence with naked eye from carbon nanotube electron beam exposed silicon dioxide (SiO{sub 2}) thin film on Si substrate. The luminescence shows a peak intensity at 2.7 eV (460 nm) with wide spread up to 600 nm after the C-beam exposed on SiO{sub 2} thin film. The C-beam exposure system is composed of carbon nanotube emitters as electron beam source. The brightness strongly depend on the exposure condition. Luminescence characteristic was optimized by C-beam adjustment to observe with the naked eye. The cause of luminescence in the C-beam exposed SiO{sub 2} thin film is analyzed by CL microscopy, FT-IR, AFM and ellipsometer. Decrease of Si–O bonding was observed after C-beam exposure, and this reveals that oxygen deficient defects which are irradiation-sensitive cause 2.7 eV peak of luminescence. - Highlights: • We observed bright luminescence for SiO{sub 2} thin film with naked eye by carbon nanotube electron beam (C-beam) exposure technique. • The bright luminance from C-beam exposed SiO{sub 2} film will open novel silicon optoelectronics.

  6. The prediction of spherical aberration with schematic eyes.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1996-07-01

    Many model eyes have been proposed; they differ in optical characteristics and therefore have different aberrations and image quality. In predicting the visual performance of the eye, we are most concerned with the central foveal vision. Spherical aberration is the only on-axis monochromatic aberration and can be used as a criterion to assess the degree of resemblance of eye models to the human eye. We reviewed and compiled experimental values of the spherical aberration of the eye, calculated the spherical aberration of several different categories of model eyes and compared the calculated results to the experimental data. Results show an over-estimation of spherical aberration by all models, the finite schematic eyes predicting values of spherical aberration closest to the experimental data. Current model eyes do not predict the average experimental values of the spherical aberration of the eye. A new model eye satisfying this assessment criterion is required for investigations of the visual performance of the eye.

  7. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    Science.gov (United States)

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  8. Renewable energy resources

    DEFF Research Database (Denmark)

    Ellabban, Omar S.; Abu-Rub, Haitham A.; Blaabjerg, Frede

    2014-01-01

    Electric energy security is essential, yet the high cost and limited sources of fossil fuels, in addition to the need to reduce greenhouse gasses emission, have made renewable resources attractive in world energy-based economies. The potential for renewable energy resources is enormous because...... they can, in principle, exponentially exceed the world's energy demand; therefore, these types of resources will have a significant share in the future global energy portfolio, much of which is now concentrating on advancing their pool of renewable energy resources. Accordingly, this paper presents how...... renewable energy resources are currently being used, scientific developments to improve their use, their future prospects, and their deployment. Additionally, the paper represents the impact of power electronics and smart grid technologies that can enable the proportionate share of renewable energy...

  9. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Directory of Open Access Journals (Sweden)

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  10. Pseudoexfoliation Glaucoma in the National Eye Center, Cicendo Eye Hospital, January–October 2012

    Directory of Open Access Journals (Sweden)

    Rizki Fasa Ramdhani

    2015-03-01

    Full Text Available Background: Pseudoexfoliation syndrome is characterized by the deposition of a distinctive fibrillar material in the anterior segment of the eye. This condition is a major risk factor for development of glaucoma, termed pseudoexfoliation glaucoma (PEXG. The aim of this study was to describe the characteristic and management of PEXG in the National Eye Center Cicendo Eye Hospital. Methods: A descriptive retrospective study was conducted in October–November 2012 using medical records of PEXG patients in the National Eye Center Cicendo Eye Hospital during January–October 2012. Results: There were 32 patients (43 eyes diagnosed as PEXG, most of them were male (78.1%, age 70–74 years old (34.4% and followed by those in the range of age 65–69 years old (21.9%. Most of the cases were unilateral (65.6% decrease of visual acuity less than 3/60 (76.7%, increase of intraocular pressure (IOP with majority in the range of 31–40 mmHg (32.6% and 41–50 mmHg (32.6%, Cup/Disc Ratio 0.9–1.0 (46.51% and followed by those classified as majority which were hard to assess because of the presence of opaque media (34.89%. The type of glaucoma was open angle glaucoma (88.4%. The treatment received was a combination of two types of antiglaucoma medication and surgery IOP Conclusion: PEXG is mostly found in elderly patients. While most of the patients come with high IOP and late stage of the disease IOP

  11. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  12. Ivermectin for onchocercal eye disease (river blindness)

    Science.gov (United States)

    Ejere, Henry OD; Schwartz, Ellen; Wormald, Richard; Evans, Jennifer R

    2015-01-01

    Background It is believed that ivermectin (a microfilaricide) could prevent blindness due to onchocerciasis. However, when given to everyone in communities where onchocerciasis is common, the effects of ivermectin on lesions affecting the eye are uncertain and data on whether the drug prevents visual loss are unclear. Objectives The aim of this review was to assess the effectiveness of ivermectin in preventing visual impairment and visual field loss in onchocercal eye disease. The secondary aim was to assess the effects of ivermectin on lesions affecting the eye in onchocerciasis. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 3), MEDLINE (January 1950 to April 2012), EMBASE (January 1980 to April 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 2 April 2012. Selection criteria We included randomised controlled trials with at least one year of follow-up comparing ivermectin with placebo or no treatment. Participants in the trials were people normally resident in endemic onchocercal communities with or without one or more characteristic signs of ocular onchocerciasis. Data collection and analysis Two review authors independently extracted data and assessed trial quality. We contacted study authors for additional information. As trials varied in design and setting, we were unable to perform a meta-analysis. Main results The review included four trials: two small studies (n = 398) in which people with onchocercal infection were given one dose of ivermectin or placebo and followed up for one year; and two larger community-based studies (n = 4941) whereby all individuals in

  13. Project BioEYES: Accessible Student-Driven Science for K-12 Students and Teachers.

    Science.gov (United States)

    Shuda, Jamie R; Butler, Valerie G; Vary, Robert; Farber, Steven A

    2016-11-01

    BioEYES, a nonprofit outreach program using zebrafish to excite and educate K-12 students about science and how to think and act like scientists, has been integrated into hundreds of under-resourced schools since 2002. During the week-long experiments, students raise zebrafish embryos to learn principles of development and genetics. We have analyzed 19,463 participating students' pre- and post-tests within the program to examine their learning growth and attitude changes towards science. We found that at all grade levels, BioEYES effectively increased students' content knowledge and produced favorable shifts in students' attitudes about science. These outcomes were especially pronounced in younger students. Having served over 100,000 students, we find that our method for providing student-centered experiences and developing long-term partnerships with teachers is essential for the growth and sustainability of outreach and school collaborations.

  14. Eye Movements When Viewing Advertisements

    Directory of Open Access Journals (Sweden)

    Emily eHiggins

    2014-03-01

    Full Text Available In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads, before turning to a consideration of advertisements in dynamic media (television and the Internet. Finally, we propose topics and methodological approaches that may prove to be useful in future research.

  15. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Directory of Open Access Journals (Sweden)

    Colleen T O'Rourke

    Full Text Available BACKGROUND: Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. METHODOLOGY/PRINCIPAL FINDINGS: We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33° and wide blind areas (∼82°, but intermediate degree of eye movement (∼5°, which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°, small blind areas (∼60°, and high degree of eye movement (∼8°, which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1° may help stabilize the image when hovering above prey before an attack. CONCLUSIONS: We conclude that: (a there are between-species differences in visual field configuration in these diurnal raptors; (b these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats; (c variations in the degree of eye movement between species appear associated with foraging strategies; and (d the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence

  16. Hawk eyes I: diurnal raptors differ in visual fields and degree of eye movement.

    Science.gov (United States)

    O'Rourke, Colleen T; Hall, Margaret I; Pitlik, Todd; Fernández-Juricic, Esteban

    2010-09-22

    Different strategies to search and detect prey may place specific demands on sensory modalities. We studied visual field configuration, degree of eye movement, and orbit orientation in three diurnal raptors belonging to the Accipitridae and Falconidae families. We used an ophthalmoscopic reflex technique and an integrated 3D digitizer system. We found inter-specific variation in visual field configuration and degree of eye movement, but not in orbit orientation. Red-tailed Hawks have relatively small binocular areas (∼33°) and wide blind areas (∼82°), but intermediate degree of eye movement (∼5°), which underscores the importance of lateral vision rather than binocular vision to scan for distant prey in open areas. Cooper's Hawks' have relatively wide binocular fields (∼36°), small blind areas (∼60°), and high degree of eye movement (∼8°), which may increase visual coverage and enhance prey detection in closed habitats. Additionally, we found that Cooper's Hawks can visually inspect the items held in the tip of the bill, which may facilitate food handling. American Kestrels have intermediate-sized binocular and lateral areas that may be used in prey detection at different distances through stereopsis and motion parallax; whereas the low degree eye movement (∼1°) may help stabilize the image when hovering above prey before an attack. We conclude that: (a) there are between-species differences in visual field configuration in these diurnal raptors; (b) these differences are consistent with prey searching strategies and degree of visual obstruction in the environment (e.g., open and closed habitats); (c) variations in the degree of eye movement between species appear associated with foraging strategies; and (d) the size of the binocular and blind areas in hawks can vary substantially due to eye movements. Inter-specific variation in visual fields and eye movements can influence behavioral strategies to visually search for and track prey while

  17. Impact of Dry Eye Disease on Work Productivity, and Patients' Satisfaction With Over-the-Counter Dry Eye Treatments.

    Science.gov (United States)

    Nichols, Kelly K; Bacharach, Jason; Holland, Edward; Kislan, Thomas; Shettle, Lee; Lunacsek, Orsolya; Lennert, Barb; Burk, Caroline; Patel, Vaishali

    2016-06-01

    To assess the effect of dry eye disease on work productivity and performance of non-work-related activities, and patients' satisfaction with over-the-counter (OTC) dry eye treatments. In this prospective, noninterventional, cross-sectional study, conducted at 10 U.S. optometry/ophthalmology practices, 158 symptomatic dry eye patients naïve to prescription medication underwent standard dry eye diagnostic tests and completed Work Productivity and Activity Impairment (WPAI) and Ocular Surface Disease Index (OSDI) questionnaires. Use of OTC dry eye medication, and satisfaction with OTC medication and symptom relief were also assessed. On average, dry eye resulted in loss of 0.36% of work time (∼5 minutes over 7 days) and ∼30% impairment of workplace performance (presenteeism), work productivity, and non-job-related activities. Presenteeism and productivity impairment scores showed significant correlation with OSDI total (r = 0.55) and symptom domain (r = 0.50) scores, but not with dry eye clinical signs. Activity impairment score showed stronger correlation with OSDI total (r = 0.61) and symptom domain (r = 0.53) scores than with clinical signs (r ≤ 0.20). Almost 75% of patients used OTC dry eye medication. Levels of patient satisfaction with OTC medication (64.2%) and symptom relief from OTC (37.3%) were unaffected by administration frequency (≥3 vs. ≤2 times daily). Dry eye causes negligible absenteeism, but markedly reduces workplace and non-job-related performances. Impairment of work performance is more closely linked to dry eye symptoms than to clinical signs. Patients' perceptions of OTC dry eye medication tend to be more positive than their perceptions of symptom relief.

  18. Iris coloboma in one eye and pigment dispersion syndrome in the fellow eye.

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Valarezo, Paul; Prada, Angélica M

    2013-05-22

    We report a case of a 43-year-old patient with coloboma of the iris, zonule, ciliary body, choroid and retina in the right eye and pigment dispersion syndrome in the left eye. Considering the hypothesis of the pigment dispersion syndrome pathogenesis in which a difference of pressures in the anterior and posterior chambers creates a posterior convexity of the iris leading to reverse pupillary block, iris touch and consequently causing pigment dispersion, we suggest that the presence of an iris coloboma, by equalising the pressures in the two chambers, prevented the onset of syndrome in that eye.

  19. Resolution and sensitivity of the eyes of the Asian honeybees Apis florea, Apis cerana and Apis dorsata.

    Science.gov (United States)

    Somanathan, Hema; Warrant, Eric J; Borges, Renee M; Wallén, Rita; Kelber, Almut

    2009-08-01

    Bees of the genus Apis are important foragers of nectar and pollen resources. Although the European honeybee, Apis mellifera, has been well studied with respect to its sensory abilities, learning behaviour and role as pollinators, much less is known about the other Apis species. We studied the anatomical spatial resolution and absolute sensitivity of the eyes of three sympatric species of Asian honeybees, Apis cerana, Apis florea and Apis dorsata and compared them with the eyes of A. mellifera. Of these four species, the giant honeybee A. dorsata (which forages during moonlit nights) has the lowest spatial resolution and the most sensitive eyes, followed by A. mellifera, A. cerana and the dwarf honeybee, A. florea (which has the smallest acceptance angles and the least sensitive eyes). Moreover, unlike the strictly diurnal A. cerana and A. florea, A. dorsata possess large ocelli, a feature that it shares with all dim-light bees. However, the eyes of the facultatively nocturnal A. dorsata are much less sensitive than those of known obligately nocturnal bees such as Megalopta genalis in Panama and Xylocopa tranquebarica in India. The differences in sensitivity between the eyes of A. dorsata and other strictly diurnal Apis species cannot alone explain why the former is able to fly, orient and forage at half-moon light levels. We assume that additional neuronal adaptations, as has been proposed for A. mellifera, M. genalis and X. tranquebarica, might exist in A. dorsata.

  20. Blurring emotional memories using eye movements: individual differences and speed of eye movements

    Directory of Open Access Journals (Sweden)

    Kevin van Schie

    2016-07-01

    Full Text Available Background: In eye movement desensitization and reprocessing (EMDR, patients make eye movements (EM while recalling traumatic memories. Making EM taxes working memory (WM, which leaves less resources available for imagery of the memory. This reduces memory vividness and emotionality during future recalls. WM theory predicts that individuals with small working memory capacities (WMCs benefit more from low levels of taxing (i.e., slow EM whereas individuals with large WMC benefit more from high levels of taxing (i.e., fast EM. Objective: We experimentally examined and tested four prespecified hypotheses regarding the role of WMC and EM speed in reducing emotionality and vividness ratings: 1 EM—regardless of WMC and EM speed—are more effective compared to no dual task, 2 increasing EM speed only affects the decrease in memory ratings irrespective of WMC, 3 low-WMC individuals—compared to high-WMC individuals—benefit more from making either type of EM, 4 the EM intervention is most effective when—as predicted by WM theory—EM are adjusted to WMC. Method: Undergraduates with low (n=31 or high (n=35 WMC recalled three emotional memories and rated vividness and emotionality before and after each condition (recall only, recall + slow EM, and recall + fast EM. Results: Contrary to the theory, the data do not support the hypothesis that EM speed should be adjusted to WMC (hypothesis 4. However, the data show that a dual task in general is more effective in reducing memory ratings than no dual task (hypothesis 1, and that a more cognitively demanding dual task increases the intervention's effectiveness (hypothesis 2. Conclusions: Although adjusting EM speed to an individual's WMC seems a straightforward clinical implication, the data do not show any indication that such a titration is helpful.

  1. Blurring emotional memories using eye movements: individual differences and speed of eye movements.

    Science.gov (United States)

    van Schie, Kevin; van Veen, Suzanne C; Engelhard, Iris M; Klugkist, Irene; van den Hout, Marcel A

    2016-01-01

    In eye movement desensitization and reprocessing (EMDR), patients make eye movements (EM) while recalling traumatic memories. Making EM taxes working memory (WM), which leaves less resources available for imagery of the memory. This reduces memory vividness and emotionality during future recalls. WM theory predicts that individuals with small working memory capacities (WMCs) benefit more from low levels of taxing (i.e., slow EM) whereas individuals with large WMC benefit more from high levels of taxing (i.e., fast EM). We experimentally examined and tested four prespecified hypotheses regarding the role of WMC and EM speed in reducing emotionality and vividness ratings: 1) EM-regardless of WMC and EM speed-are more effective compared to no dual task, 2) increasing EM speed only affects the decrease in memory ratings irrespective of WMC, 3) low-WMC individuals-compared to high-WMC individuals-benefit more from making either type of EM, 4) the EM intervention is most effective when-as predicted by WM theory-EM are adjusted to WMC. Undergraduates with low (n=31) or high (n=35) WMC recalled three emotional memories and rated vividness and emotionality before and after each condition (recall only, recall + slow EM, and recall + fast EM). Contrary to the theory, the data do not support the hypothesis that EM speed should be adjusted to WMC (hypothesis 4). However, the data show that a dual task in general is more effective in reducing memory ratings than no dual task (hypothesis 1), and that a more cognitively demanding dual task increases the intervention's effectiveness (hypothesis 2). Although adjusting EM speed to an individual's WMC seems a straightforward clinical implication, the data do not show any indication that such a titration is helpful.

  2. The influence of protein free calf blood extract eye gel on dry eye after pterygium surgery

    Directory of Open Access Journals (Sweden)

    Cai-Ni Ji

    2013-07-01

    Full Text Available AIM: To investigate the influence of protein free calf blood extract eye gel on dry eye after pterygium surgery. METHODS: Thirty six patients(40 eyeswith primary nasal pterygium were enrolled in this study, which were divided into study group and control group randomly, with 20 eyes in each group. All patients received pterygium excision and limbal stem cell autograft surgery and tobramicin dexamethasone eye drops after surgery. Patients of the study group received protein free calf blood extract eye gel while those of the control group received 0.1% sodium hyaluronate eye drops furthermore. Ocular surface disease index(OSDIquestionnaire, tear film break-up time(BUTand Schirmer's Ⅰ test Ⅰ(SⅠtwere carried before and 3 months after surgery to evaluate the dry eye degree of the patients. RESULTS: There was no statistical difference between the age, gender and size of the pterygium of the study and control groups preoperatively. There was no statistical difference between the OSDI(2.33±1.02 vs 2.32±0.93, BUT(8.80±2.48 vs 8.35±2.28seconds and SⅠt(4.30±2.30 vs 4.40±2.44of the two groups preoperatively. There was statistical difference between the OSDI(1.45±0.47 vs 1.81±0.60, BUT(11.20±2.07 vs 9.50±2.40seconds and SⅠt(8.35±3.13 vs 6.35±2.18of the two groups 3 months postoperatively, which was also different from that of the preoperative data correspondingly. CONCLUSION: Protein free calf blood extract eye gel could reduce the dry eye after pterygium surgery.

  3. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    Science.gov (United States)

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  4. The medical eye: Conclusions from eye tracking research on expertise development in medicine

    NARCIS (Netherlands)

    Jarodzka, Halszka; Jaarsma, Thomas; Dewhurst, Richard; Boshuizen, Els

    2013-01-01

    Jarodzka, H., Jaarsma, T., Dewhurst, R., & Boshuizen, H. P. A. (2012, October). The medical eye: Conclusions from eye tracking research on expertise development in medicine. Paper presented at the New tools and practices for seeing and learning in medicine ’12, University of Turku, Turku, Finland.

  5. Covering one eye in fixation-disparity measurement causes slight movement of fellow eye

    NARCIS (Netherlands)

    Simonsz, H. J.; Bour, L. J.

    1991-01-01

    In the subjective measurement of fixation disparity (FD), the subject fuses contours presented in the peripheral macular areas of both eyes (fusion lock). The position of the eyes relative to each other is monitored by means of two haploscopically seen vertical lines presented in the central macular

  6. The eyes of mesopelagic crustaceans. III. Thysanopoda tricuspidata (Euphausiacea).

    Science.gov (United States)

    Meyer-Rochow, V B; Walsh, S

    1978-12-14

    The compound eyes of the mesopelagic eupausiid Thysanopoda tricuspidata were investigated by light-, scanning-, and transmission electron microscopy. The eyes are spherical and have a diameter that corresponds to 1/6 of the carapace length. The hexagonal facets have strongly curved outer surfaces. Although there are four crystalline cone cells, only two participate in the formation of the cone, which is 90-120 micrometer long and appears to have a radial gradient of refractive index. The clear zone, separating dioptric structures and retinula, is only 90-120 micrometer wide. In it lie the very large oval nuclei of the seven retinula cells. Directly in front of the 70 micrometer long and 15 micrometer thick rhabdom a lens-like structure of 12 micrometer diameter is developed. This structure, known in only a very few arthropods, seems to be present in all species of Euphausiacea studied to date. It is believed that the rhabdom lens improves near-field vision and absolute light sensitivity. Rod-shaped pigment grains and mitochondria of the tubular type are found in the plasma of retinula cells. The position of the proximal screening pigment as well as the microvillar organization in the rhabdom are indicative of light-adapted material. The orthogonal alignment of rhabdovilli suggests polarization sensitivity. Behind each rabdom there is a cup-shaped homogenous structure of unknown, but possibly optical function. Finally, the structure and the function of the euphysiid eye are reviewed and the functional implications of individual components are discussed.

  7. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  8. [Eye contact effects: A therapeutic issue?

    Science.gov (United States)

    Baltazar, M; Conty, L

    2016-12-01

    The perception of a direct gaze - that is, of another individual's gaze directed at the observer that leads to eye contact - is known to influence a wide range of cognitive processes and behaviors. We stress that these effects mainly reflect positive impacts on human cognition and may thus be used as relevant tools for therapeutic purposes. In this review, we aim (1) to provide an exhaustive review of eye contact effects while discussing the limits of the dominant models used to explain these effects, (2) to illustrate the therapeutic potential of eye contact by targeting those pathologies that show both preserved gaze processing and deficits in one or several functions that are targeted by the eye contact effects, and (3) to propose concrete ways in which eye contact could be employed as a therapeutic tool. (1) We regroup the variety of eye contact effects into four categories, including memory effects, activation of prosocial behavior, positive appraisals of self and others and the enhancement of self-awareness. We emphasize that the models proposed to account for these effects have a poor predictive value and that further descriptions of these effects is needed. (2) We then emphasize that people with pathologies that affect memory, social behavior, and self and/or other appraisal, and self-awareness could benefit from eye contact effects. We focus on depression, autism and Alzheimer's disease to illustrate our proposal. To our knowledge, no anomaly of eye contact has been reported in depression. Patients suffering from Alzheimer disease, at the early and moderate stage, have been shown to maintain a normal amount of eye contact with their interlocutor. We take into account that autism is controversial regarding whether gaze processing is preserved or altered. In the first view, individuals are thought to elude or omit gazing at another's eyes while in the second, individuals are considered to not be able to process the gaze of others. We adopt the first stance

  9. [Firework-related eye trauma from 2005 to 2013].

    Science.gov (United States)

    Unterlauft, J D; Wiedemann, P; Meier, P

    2014-09-01

    Fireworks combusted during New Year's Eve festivities can cause different eye traumas which often need complex reconstructive surgery. It was our aim to systematically analyse these eye trauma cases which were treated at our clinic during the last eight years. Age, gender, side, trauma mechanism, treatment methods and outcome were analysed for all eye trauma cases caused by fireworks during the New Year's Eve celebrations from 2006 to 2013. For statistical analysis all trauma cases were divided into two groups of major and non-major eye trauma. The total number of patients treated was 122 (28 women, 94 men, mean age 26.2±13.0 years) with 137 traumatised eyes (77 right, 60 left). 24.6% of patients were ≤18 years of age. 76.2% were bystanders. 50 eyes from 46 patients (37.7%) suffered from major eye trauma. 26 patients (21.3%) were hospitalised. 8 eyes (5.8%) suffered from a penetrating injury or globe rupture and underwent primary reconstructive surgery. Further 16 eyes (11.7%) suffered from major eye trauma without open globe injury. In the aftermath 11 eyes (8.0%) went blind (visual acuityfireworks. However older patients suffer from major eye trauma more often. More education and prophylaxis of eye trauma caused by fireworks is desirable. Georg Thieme Verlag KG Stuttgart · New York.

  10. 21 CFR 886.4750 - Ophthalmic eye shield.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4750 Ophthalmic eye shield. (a) Identification. An ophthalmic eye shield is a device that consists of a plastic or aluminum eye covering intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic eye shield. 886.4750 Section 886.4750...

  11. Apoptosis in the eye.

    OpenAIRE

    Chahory , Sabine; Torriglia , Alicia

    2006-01-01

    Apoptosis is a normal component of the development and health of multicellular organisms. Cells die during apoptosis in a controlled, regulated fashion. This form of cell death is very important in eye development as well as in eye pathology. We review in this chapter our current knowledge in this topic.

  12. Empowering Teachers to Author Multimedia Learning Resources That Support Students' Critical Thinking

    Science.gov (United States)

    Holley, Debbie; Boyle, Tom

    2012-01-01

    Students studying Marketing, Fashion, Public Relations, Advertising and similar subjects need to develop a "critical eye" in relation to images, media and digital technologies. This project aims to empower teachers to develop multimedia learning resources that would support students engaging in this essential activity. Developing such…

  13. Eye-like ocelloids are built from different endosymbiotically acquired components

    KAUST Repository

    Gavelis, Gregory S.; Hayakawa, Shiho; White, Richard A.; Gojobori, Takashi; Suttle, Curtis A.; Keeling, Patrick J.; Leander, Brian S.

    2015-01-01

    Multicellularity is often considered a prerequisite for morphological complexity, as seen in the camera-type eyes found in several groups of animals. A notable exception exists in single-celled eukaryotes called dinoflagellates, some of which have an eye-like 'ocelloid' consisting of subcellular analogues to a cornea, lens, iris, and retina. These planktonic cells are uncultivated and rarely encountered in environmental samples, obscuring the function and evolutionary origin of the ocelloid. Here we show, using a combination of electron microscopy, tomography, isolated-organelle genomics, and single-cell genomics, that ocelloids are built from pre-existing organelles, including a cornea-like layer made of mitochondria and a retinal body made of anastomosing plastids. We find that the retinal body forms the central core of a network of peridinin-type plastids, which in dinoflagellates and their relatives originated through an ancient endosymbiosis with a red alga. As such, the ocelloid is a chimaeric structure, incorporating organelles with different endosymbiotic histories. The anatomical complexity of single-celled organisms may be limited by the components available for differentiation, but the ocelloid shows that pre-existing organelles can be assembled into a structure so complex that it was initially mistaken for a multicellular eye. Although mitochondria and plastids are acknowledged chiefly for their metabolic roles, they can also be building blocks for greater structural complexity.

  14. Eye-like ocelloids are built from different endosymbiotically acquired components

    KAUST Repository

    Gavelis, Gregory S.

    2015-07-01

    Multicellularity is often considered a prerequisite for morphological complexity, as seen in the camera-type eyes found in several groups of animals. A notable exception exists in single-celled eukaryotes called dinoflagellates, some of which have an eye-like \\'ocelloid\\' consisting of subcellular analogues to a cornea, lens, iris, and retina. These planktonic cells are uncultivated and rarely encountered in environmental samples, obscuring the function and evolutionary origin of the ocelloid. Here we show, using a combination of electron microscopy, tomography, isolated-organelle genomics, and single-cell genomics, that ocelloids are built from pre-existing organelles, including a cornea-like layer made of mitochondria and a retinal body made of anastomosing plastids. We find that the retinal body forms the central core of a network of peridinin-type plastids, which in dinoflagellates and their relatives originated through an ancient endosymbiosis with a red alga. As such, the ocelloid is a chimaeric structure, incorporating organelles with different endosymbiotic histories. The anatomical complexity of single-celled organisms may be limited by the components available for differentiation, but the ocelloid shows that pre-existing organelles can be assembled into a structure so complex that it was initially mistaken for a multicellular eye. Although mitochondria and plastids are acknowledged chiefly for their metabolic roles, they can also be building blocks for greater structural complexity.

  15. New Perspectives on Dry Eye Definition and Diagnosis: A Consensus Report by the Asia Dry Eye Society.

    Science.gov (United States)

    Tsubota, Kazuo; Yokoi, Norihiko; Shimazaki, Jun; Watanabe, Hitoshi; Dogru, Murat; Yamada, Masakazu; Kinoshita, Shigeru; Kim, Hyo-Myung; Tchah, Hung-Won; Hyon, Joon Young; Yoon, Kyung-Chul; Seo, Kyoung Yul; Sun, Xuguang; Chen, Wei; Liang, Lingyi; Li, Mingwu; Liu, Zuguo

    2017-01-01

    For the last 20 years, a great amount of evidence has accumulated through epidemiological studies that most of the dry eye disease encountered in daily life, especially in video display terminal (VDT) workers, involves short tear film breakup time (TFBUT) type dry eye, a category characterized by severe symptoms but minimal clinical signs other than short TFBUT. An unstable tear film also affects the visual function, possibly due to the increase of higher order aberrations. Based on the change in the understanding of the types, symptoms, and signs of dry eye disease, the Asia Dry Eye Society agreed to the following definition of dry eye: "Dry eye is a multifactorial disease characterized by unstable tear film causing a variety of symptoms and/or visual impairment, potentially accompanied by ocular surface damage." The definition stresses instability of the tear film as well as the importance of visual impairment, highlighting an essential role for TFBUT assessment. This paper discusses the concept of Tear Film Oriented Therapy (TFOT), which evolved from the definition of dry eye, emphasizing the importance of a stable tear film. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  16. Generating and Describing Affective Eye Behaviors

    Science.gov (United States)

    Mao, Xia; Li, Zheng

    The manner of a person's eye movement conveys much about nonverbal information and emotional intent beyond speech. This paper describes work on expressing emotion through eye behaviors in virtual agents based on the parameters selected from the AU-Coded facial expression database and real-time eye movement data (pupil size, blink rate and saccade). A rule-based approach to generate primary (joyful, sad, angry, afraid, disgusted and surprise) and intermediate emotions (emotions that can be represented as the mixture of two primary emotions) utilized the MPEG4 FAPs (facial animation parameters) is introduced. Meanwhile, based on our research, a scripting tool, named EEMML (Emotional Eye Movement Markup Language) that enables authors to describe and generate emotional eye movement of virtual agents, is proposed.

  17. The genetics of eye colours in an Italian population measured with an objective method for eye colour quantification

    DEFF Research Database (Denmark)

    Pietroni, C.; Andersen, J.D.; Johansen, P.

    2013-01-01

    Brown and blue eye colours are primarily explained by the single nucleotide polymorphism (SNP) HERC2 rs12913832. However, the genetics of eye colours that appear to be neither blue nor brown are not well understood. In this study, 230 unrelated Italian individuals were typed for 32 SNP loci...... in the iris region and calculated a Pixel Index of the Eye (PIE-score) that described the eye colours quantitatively. The PIE-score ranged from _1 to 1 (brown to blue). We investigated the association of the PIE-scores extracted from the eye images with the genotypes of the 32 pigmentary SNPs. We observed...

  18. Maxwellian Eye Fixation during Natural Scene Perception

    Directory of Open Access Journals (Sweden)

    Jean Duchesne

    2012-01-01

    Full Text Available When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell’s law for each participant and for each scene condition (normal or scrambled. The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes.

  19. Maxwellian Eye Fixation during Natural Scene Perception

    Science.gov (United States)

    Duchesne, Jean; Bouvier, Vincent; Guillemé, Julien; Coubard, Olivier A.

    2012-01-01

    When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF) of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell's law for each participant and for each scene condition (normal or scrambled). The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes. PMID:23226987

  20. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.