WorldWideScience

Sample records for extracted beam line

  1. DIAGNOSIS OF THE LOW EMITTANCE BEAM IN ATF DR EXTRACTION LINE

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, Douglas

    2003-05-06

    The ATF (Accelerator Test Facility in KEK) damping ring has been designed to produce the low emittance beam required by future linear colliders. In the design, the normalized vertical emittance of the ATF damping ring is 3.0E-8 radm which corresponds to the vertical beam size of about 10 micron in the extraction line. The emittance of the beam extracted from the ATF damping ring is measured with four wire scanners located in a dispersion free region of the extraction line. The optics of the extraction line is also studied. We will report the method and the result of the emittance measurement at the extraction line.

  2. BEAM EXTRACTION FROM THE RECYCLER RING TO P1 LINE AT FERMILAB

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, M. [Fermilab; Capista, D. [Fermilab; Adams, P. [Fermilab; Morris, D. [Fermilab; Yang, M. J. [Fermilab; Hazewood, K. [Fermilab

    2016-10-03

    The transfer line for beam extraction from the Recycler ring to P1 line provides a way to deliver 8 GeV kinetic energy protons from the Booster to the Delivery ring, via the Recycler, using existing beam transport lines, and without the need for new civil construction. It was designed in 2012. The kicker magnets at RR520 and the lambertson magnet at RR522 in the RR were installed in 2014 Summer Shutdown, the elements of RR to P1 Stub (permanent quads, trim quads, correctors, BPMs, the toroid at 703 and vertical bending dipole at V703 (ADCW) were installed in 2015 Summer Shutdown. On Tuesday, June 21, 2016, beam line from the Recycler Ring to P1 line was commissioned. The detailed results will be presented in this report.

  3. Evaluation and Compensation of Detector Solenoid Effects on Disrupted Beam in the ILC 14 mrad Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Toprek, Dragan; /VINCA Inst. Nucl. Sci., Belgrade; Nosochkov, Yuri; /SLAC

    2008-12-18

    This paper presents calculations of detector solenoid effects on disrupted primary beam in the ILC 14 mrad extraction line. Particle tracking simulations are performed for evaluation of primary beam loss along the line as well as of beam distribution and polarization at Compton Interaction Point. The calculations are done both without and with solenoid compensation. The results are obtained for the baseline ILC energy of 500 GeV center-of-mass and three options of beam parameters.

  4. SIMULATION OF NEUTRON BACKGROUNDS FROM THE ILC EXTRACTION LINE BEAM DUMP

    Energy Technology Data Exchange (ETDEWEB)

    Darbha, S; Keller, L.; Maruyama, T.

    2008-01-01

    The operation of the International Linear Collider (ILC) as a precision measurement machine is dependent upon the quality of the charge-coupled device (CCD) silicon vertex detector. An integrated fl ux of 1010 neutrons/cm2 incident upon the vertex detector will degrade its performance by causing displacement damage in the silicon. One source of the neutron background arises from the dumping of the spent electron and positron beams into the extraction line beam dumps. The Monte Carlo program FLUKA was used to simulate the collision of the electron beam with the dump and to determine the resulting neutron fl ux at the interaction point (IP). A collimator and tunnel were added and their effect on the fl ux was analyzed. A neutron source was then generated and directed along the extraction line towards a model of the vertex detector to determine the neutron fl ux in its silicon layers. Models of the beampipe and BeamCal, a silicon-tungsten electromagnetic calorimeter in the very forward region of the detector, were placed in the extraction line and their effects on scattering were studied. The IP fl uence was determined to be 3.7x1010 +/- 2.3x1010 neutrons/cm2/year when the tunnel and collimator were in place, with no appreciable increase in statistics when the tunnel was removed. The BeamCal was discovered to act as a collimator by signifi cantly impeding the fl ow of neutrons towards the detector. The majority of damage done to the fi rst layer of the detector was found to come from neutrons with a direct line of sight from the fi rst extraction line quadrupole QDEX1, with only a small fraction scattering off of the beampipe and into the detector. The 1 MeV equivalent neutron fl uence was determined to be 9.3x108 neutrons/cm2/year from the electron beam alone. The two beams collectively contribute double to this fl uence, which is 19% of the threshold value in one year. Future work will improve the detector model and other sources of neutron backgrounds will be

  5. Design of the extraction arc for the 2{sup nd} beam line of the free-electron laser FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, Matthias

    2014-01-15

    In this thesis, I deal with the design of the extraction arc for the second beam line of FLASH, an FEL (Free-Electron Laser) user facility at DESY Hamburg. Both beam lines will use the same linear accelerator and their separation will take place behind the last accelerating module. I present the constraints for the extraction arc given by the beam line layout of the existing machine, by the building environment of the new beam line and in particular, by coherent synchrotron radiation (CSR). The impact from CSR is presented, and I show how to mitigate these effects and what that means for the beam line design. The optimization of the extraction arc was done applying the downhill simplex algorithm which is presented, first in its basic form to explain the operation principle and then in a more advanced version as used in the applied program. I introduce in this thesis the final layout of the extraction arc including the following matching section. This layout fulfills all given constraints and can provide the required electron beam quality for FEL operation. In order to prove this, I present start-to-end simulations for different bunch charges and for two different wavelengths.

  6. LEAR: antiproton extraction lines

    CERN Multimedia

    Photographic Service

    1992-01-01

    Antiprotons, decelerated in LEAR to a momentum of 100 MeV/c (kinetic energy of 5.3 MeV), were delivered to the experiments in an "Ultra-Slow Extraction", dispensing some 1E9 antiprotons over times counted in hours. Beam-splitters and a multitude of beam-lines allowed several users to be supplied simultaneously.

  7. A new concept for the control of a slow-extracted beam in a line with rotational optics, 2

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    For pt.I see ibid., vol.430, p.512-22, 1999. The current trend in hadron therapy is towards high-precision, conformal scanning of tumours with a `pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow- extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer- pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from `hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined p...

  8. A new concept for the control of a slow-extracted beam in a line with rotational optics: Part II

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    The current trend in hadrontherapy is towards high-precision, conformal scanning of tumours with a 'pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow-extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer-pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from 'hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined phase shifter and 'stepper', at a point close to ...

  9. High energy beam lines

    Science.gov (United States)

    Marchetto, M.; Laxdal, R. E.

    2014-01-01

    The ISAC post accelerator comprises an RFQ, DTL and SC-linac. The high energy beam lines connect the linear accelerators as well as deliver the accelerated beams to two different experimental areas. The medium energy beam transport (MEBT) line connects the RFQ to the DTL. The high energy beam transport (HEBT) line connects the DTL to the ISAC-I experimental stations (DRAGON, TUDA-I, GPS). The DTL to superconducting beam (DSB) transport line connects the ISAC-I and ISAC-II linacs. The superconducting energy beam transport (SEBT) line connects the SC linac to the ISAC-II experimental station (TUDA-II, HERACLES, TIGRESS, EMMA and GPS). All these lines have the function of transporting and matching the beams to the downstream sections by manipulating the transverse and longitudinal phase space. They also contain diagnostic devices to measure the beam properties.

  10. Design of Air-Cooled Beam Dump for Extraction Line of PS Booster

    CERN Document Server

    Perillo-Marcone, A; Venturi, V; Antonakakis, T; Vlachoudis, V; Nowak, E; Mason, G; Battistin, M; Czapski, M; Sgobba, S

    2013-01-01

    A new beam dump has been designed, which withstands the future proton beam extracted from the Proton Syncrotron Booster (PSB) at CERN, consisting of up to 1E14 protons per pulse at 2 GeV after its upgrade in 2018/2019. In order to be able to efficiently release the deposited heat, the new dump will be made out of a single cylindrical block of a copper alloy and cooled by forced ventilation. In order to determine the energy density distribution deposited by the beam in the dump, Monte Carlo simulations were performed using FLUKA, and thermomechanical analyses carried out by importing the energy density into Ansys. In addition, CFD simulations of the airflow were carried out in order to accurately estimate the heat transfer convection coefficient on the surface of the dump. This paper describes the design process and highlights the constraints of integrating a new dump for increased beam power into the existing facility.

  11. MTN magnet for the SPS extracted beam.

    CERN Multimedia

    1976-01-01

    This type of dipole magnet was used in the extracted beam lines of the North Area. It shows an opening for three different proton beam lines: a primary extracted proton beam, split by an upstream magnetic beam splitter (see photo 7612017) into three separated beams passes through different parts of its aperture: right, left up, left down. These magnets were designed to be concrete-insulated for radiation resistance. F. Streun stands on the right.

  12. Beam Losses in the Extraction Line of a TeV E+ E- Linear Collider With a 20-Mrad Crossing Angle

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, A.; /Uppsala U.; Nosochkov, Y.; /SLAC

    2006-03-29

    In this paper, we perform a detailed study of the power losses along the postcollision extraction line of a TeV e+e- collider with a crossing angle of 20 mrad between the beams at the interaction point. Five cases are considered here: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam-beam effects at the interaction point lead to an emittance growth for the outgoing beams, as well as to the production of beamstrahlung photons and e+e- pairs. The power losses along the 20 mrad extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the e+e- coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular o set at the interaction point.

  13. Neutrino beam line optics study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ming-Jen

    1996-09-01

    A study was done to understand the beam line optics from the beginning of Switchyard all the way to the end of Neutrino beam line. All available SWIC data were taken to get the beam centroid and width to be used in the analysis. The beam emittance and lattice function at the beginning of beam line can also be inferred from the study. The result indicated that the normalized 95% emittance to be around 15 {pi}-mm-mr for the vertical plane and about 28 {pi}-mm-mr for the horizontal plane.

  14. Beam line to S155

    CERN Multimedia

    1977-01-01

    The experiment S155 was designed by the Orsay (CSNM-CNRS) Collaboration to observe the properties of exotic light nuclei. It was installed in the PS neutrino tunnel. The photo shows a mass spectrometer (in the background) on line with the PS proton beam which arrives (bottom, right) from the fast extraction FE74. Roger Fergeau stands on the left. The alkaline isotopes produced in the carbon-uranium target heated at 2000°C were swiftly extracted, mass separated, and brought to a detector behind the shielding. Sodium 34 (11 protons and 23 neutrons) was observed and its half-life of only 5 ms was measured. The excited levels 2+ of Magnesium 30 and Magnesium 32 (Sodium descendants) were localised, and the magic number 20 was found to vanish. Thus, the discovery made earlier for Sodium 30 and Sodium 32, with the same apparatus, was confirmed. (See also photo 7706511.)

  15. RIA Fragmentation Line Beam Dumps

    Energy Technology Data Exchange (ETDEWEB)

    Stein, W

    2003-08-08

    The Rare Isotope Accelerator project involves generating heavy-element ion beams for use in a fragmentation target line to produce beams for physics research. The main beam, after passing through the fragmentation target, may be dumped into a beam dump located in the vacuum cavity of the first dipole magnet. For a dump beam power of 100 kW, cooling is required to avoid excessive high temperatures. The proposed dump design involves rotating cylinders to spread out the energy deposition and turbulent subcooled water flow through internal water cooling passages to obtain high, nonboiling, cooling rates.

  16. Beam line design using G4BeamLine

    CERN Document Server

    Dogan, Arda

    2014-01-01

    In Turkey in Ankara TAEK SANAEM Proton Accelerator Facility (PAF), there is a cyclotron which produces a focused intense 30 MeV proton beam and sends this beam to four different arms, three of which uses this beam to produce pharmaceutical medicine. The remaining one is spared for R&D purposes and the idea was to use these protons coming out from the fourth arm to use space radiation tests, which cannot be done in Turkey at the moment. However, according to SCC 25100 standards which is for 30 MeV protons, the beam coming out of cyclotron is too intense and focused to use for space radiation tests. Therefore, the main aim of my project is to design a beam line which will defocus the beam and reduce the flux so that the space radiation tests can be done according to the standards of SCC 25100.

  17. ILC Extraction Line Simulations with TDR Parameters

    CERN Document Server

    Marin, Eduardo

    2014-01-01

    The goal of this study is to evaluate the impact of the latest ILC beam parameters at the Interaction Point (IP), as specified in the 2013 ILC Technical Design Report (TDR), on beam losses in the extraction line. The previous beam loss evaluation was based on the parameters specified in the 2007 ILC Reference Design Report (RDR). The results of this study are compared to the results obtained in the past for the ``nominal'' and the ``low power'' (low-P) parameter options of the RDR. The initial disrupted beam distribution at IP was generated using Guinea-Pig code, and the beam losses were obtained in tracking simulations using DIMAD. The study is performed for 500 GeV center-of-mass beam energy and the extraction line optics corresponding to the latest final focus optics with L* = 4.5 m, with and without detector solenoid.

  18. Beam stripping extraction from the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ristić-Đurović Jasna L.

    2006-01-01

    Full Text Available The extraction system of a cyclotron guides an ion beam from a spiral acceleration orbit, through an extraction trajectory, into a high energy transport line. The two methods commonly used to direct an ion into the extraction path are deflection, by the electric field of an electrostatic deflector, and ion stripping, by a thin carbon foil. Compared to the electrostatic deflector system, the stripping extraction provides a fast and easy change of the extracted ion energy and is easier to manufacture operate, and maintain. However, the extraction trajectory and dynamics of an ion beam after stripping are highly dependant on the ion energy and specific charge. Thus, when a multipurpose machine such as the VINCY Cyclotron is concerned, it is far from easy to deliver a variety of ion beams into the same high energy transport line and at the same time preserve a reasonable compactness of the extraction system. The front side stripping extraction system of the VINCY Cyclotron provides high (~70 MeV and mid (~30 MeV energy protons, as well as a number of heavy ions in broad energy ranges. The back side stripping extraction system extracts low energy protons (~18 MeV and enables their simultaneous use with high energy protons at the front side of the machine.

  19. SPS Beam Steering for LHC Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Gianfelice-Wendt, Eliana [Fermilab; Bartosik, Hannes [CERN; Cornelis, Karel [CERN; Norderhaug Drøsdal, Lene [CERN; Goddard, Brennan [CERN; Kain, Verena [CERN; Meddahi, Malika [CERN; Papaphilippou, Yannis [CERN; Wenninger, Jorg [CERN

    2014-07-01

    The CERN Super Proton Synchrotron accelerates beams for the Large Hadron Collider to 450 GeV. In addition it produces beams for fixed target facilities which adds complexity to the SPS operation. During the run 2012-2013 drifts of the extracted beam trajectories have been observed and lengthy optimizations in the transfer lines were performed to reduce particle losses in the LHC. The observed trajectory drifts are consistent with the measured SPS orbit drifts at extraction. While extensive studies are going on to understand, and possibly suppress, the source of such SPS orbit drifts the feasibility of an automatic beam steering towards a “golden” orbit at the extraction septa, by means of the interlocked correctors, is also being investigated. The challenges and constraints related to the implementation of such a correction in the SPS are described. Simulation results are presented and a possible operational steering strategy is proposed.

  20. SPS Beam Steering for LHC Extraction

    CERN Document Server

    Gianfelice Wendt, E; Cornelis, K; Norderhaug Drosdal, L; Goddard, B; Kain, V; Meddahi, M; Papaphilippou, Y; Wenninger, J

    2014-01-01

    Beside producing beams for fixed target operation, the CERN Super Proton Synchrotron (SPS) accelerates beams for injection into the Large Hadron Collider (LHC). During the 2012-2013 run drifts of the extracted beam horizontal trajectories have been observed and lengthy optimizations in the transfer lines were performed to reduce particle losses. The observed trajectory drifts are consistent with the measured SPS orbit drifts at extraction. The feasibility of an automatic beam steering towards a “golden” orbit at the extraction septa, has been therefore investigated. The challenges and constraints related to the implementation of such a correction in the SPS are described. Simulation results are presented and a possible operational steering strategy is proposed. As the observed drift is mainly horizontal, the horizontal plane only will be considered.

  1. Nonlinear optimization of beam lines

    CERN Document Server

    Tomás Garcia, Rogelio

    2006-01-01

    The current final focus systems of linear colliders have been designed based on the local compensation scheme proposed by P. Raimondi and A. Seryi [1]. However, there exist remaining aberrations that deteriorate the performance of the system. This paper develops a general algorithm for the optimization of beam lines based on the computation of the high orders of the transfer map using MAD-X [2] and PTC [3]. The algorithm is applied to the CLIC [4] Beam Delivery System (BDS).

  2. DESIGN OF ILC EXTRACTION LINE FOR 20 MRAD CROSSING ANGLE

    Energy Technology Data Exchange (ETDEWEB)

    Nosochkov, Y.; Moffeit, K.; Seryi, A.; Woods, M.; /SLAC; Arnold, R.; /Massachusetts U., Amherst; Oliver, W.; /Tufts U.; Parker, B.; /Brookhaven; Torrence, E.; /Oregon U.

    2005-05-16

    One of the two ILC Interaction Regions will have a large horizontal crossing angle which would allow to extract the spent beams in a separate beam line. In this paper, the extraction line design for 20 mrad crossing angle is presented. This beam line transports the primary e{sup +}/e{sup -} and beamstrahlung photon beams from the IP to a common dump, and includes diagnostic section for energy and polarization measurements. The optics is designed for a large energy acceptance to minimize losses in the low energy tail of the disrupted beam. The extraction optics, diagnostic instrumentation and particle tracking simulations are described.

  3. The appearance of beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Carey, D.C.

    1993-05-01

    The combination of an existing graphics package with a large program like TRANSPORT has often resulted in considerable modification to the large program. Use of other graphics package has resulted in essentially having to repeat the work. This difficulty has been avoided in a modification of TRANSPORT which produce layouts of beam lines. Drawings of the reference trajectory and three-dimensional images of all magnets are made by the graphics package TOP DRAWER. Nothing specific to TOP DRAWER or any other graphics has been incorporated into TRANSPORT. If a user is with a different graphics package he or she can then begin usage of this alternate package essentially immediately.

  4. Beam simulation studies of ECR beam extraction and low energy beam transport for FRIB.

    Science.gov (United States)

    Ren, Haitao; Pozdeyev, Eduard; Lund, Steven M; Machicoane, Guillaume; Wu, Xiaoyu; Morgan, Glenn

    2016-02-01

    To meet the beam power requirements of 400 kW at the fragmentation target for facility for Rare Isotope Beams (FRIB), simultaneous acceleration of two-charge states should be used for heavier ions. These intense multi-charged ion beams will be produced by a 28 GHz electron cyclotron resonance (ECR) ion source at a high voltage of 35 kV. After extraction, the ion beam will be pre-accelerated to 12 keV/u with a 50 kV platform, transported down to an achromatic charge state selection (CSS) system followed by a vertical transport line, and then injected into a radio frequency quadrupole accelerator. The TRACK code developed at ANL is used to perform the simulations of the ECR beam extraction and low energy beam transport for FRIB. In this study, we include the magnetic field of ECR ion source into simulations. Different initial beam conditions as well as different space charge neutralization levels are tested for the ECR beamline. The beam loss in CSS system and the corresponding protective measures are discussed. The detailed results about the beam dynamic simulation and beam loss in CSS system will be presented in this paper.

  5. Beam instrumentation for fast kicker extraction at COSY-Juelich

    Science.gov (United States)

    Dietrich, J.; Bojowald, J.; Labus, H.; Lawin, H.; Mohos, I.

    2000-11-01

    In the cooler synchrotron COSY two kinds of beam extraction were foreseen and realized: resonant extraction and stochastic extraction. Now a fast beam extraction for the new experiment JESSICA (Jülich Experimental Spallation Target Setup in COSY Area) is of great importance for prototyping the high power target of the European Spallation Source. First experiments using the kicker, originally installed for diagnostic purposes in the COSY ring, are reported. Special emphasis is given for beam diagnostics developments in the extraction beamline for measuring intensive fast proton pulses. To measure beam current and time structure a wall current monitor was installed in the extraction beam line. For more sensitive measurements in a wide range a so called universal spill measurement device, consisting of scintillators and an ionization chamber are developed.

  6. Experimental Program for the CLIC test facility 3 test beam line

    CERN Document Server

    Adli, E; Dobert, S; Olvegaard, M; Schulte, D; Syratchev, I; Lillestol, Reidar

    2010-01-01

    The CLIC Test Facility 3 Test Beam Line is the first prototype for the CLIC drive beam decelerator. Stable transport of the drive beam under deceleration is a mandatory component in the CLIC two-beam scheme. In the Test Beam Line more than 50% of the total energy will be extracted from a 150 MeV, 28 A electron drive beam, by the use of 16 power extraction and transfer structures. A number of experiments are foreseen to investigate the drive beam characteristics under deceleration in the Test Beam Line, including beam stability, beam blow up and the efficiency of the power extraction. General benchmarking of decelerator simulation and theory studies will also be performed. Specially designed instrumentation including precision BPMs, loss monitors and a time-resolved spectrometer dump will be used for the experiments. This paper describes the experimental program foreseen for the Test Beam Line, including the relevance of the results for the CLIC decelerator studies.

  7. BEAM TRANSPORT LINES FOR THE BSNS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI, J.

    2006-06-26

    This paper presents the design of two beam transport lines at the BSNS: one is the injection line from the Linac to the RCS and the other is the target line from the RCS to the target station. In the injection beam line, space charge effects, transverse halo collimation, momentum tail collimation and debunching are the main concerned topics. A new method of using triplet cells and stripping foils is used to collimate transverse halo. A long straight section is reserved for the future upgrading linac and debuncher. In the target beam line, large halo emittance, beam stability at the target due to kicker failures and beam jitters, shielding of back-scattering neutrons from the target are main concerned topics. Special bi-gap magnets will be used to reduce beam losses in the collimators in front of the target.

  8. Vortex-based line beam optical tweezers

    Science.gov (United States)

    Cheng, Shubo; Tao, Shaohua

    2016-10-01

    A vortex-based line beam, which has a straight-line shape of intensity and possesses phase gradient along the line trajectory is developed and applied for optical manipulation in this paper. The intensity and phase distributions of the beam in the imaging plane of the Fourier transform are analytically studied. Simulation results show that the length of the line and phase gradient possessed by a vortex-based line beam are dependent on the topological charge and the azimuthal proportional constant. A superposition of multiple phase-only holograms with elliptical azimuthal phases can be used to generate an array of vortex-based line beams. Optical trapping with the vortex-based line beams has been implemented. Furthermore, the automatic transportation of microparticles along the line trajectory perpendicular to the optical axis is realized with an array of the beams. The generation method for the vortex-based line beam is simple. The beam would have potential applications in fields such as optical trapping, laser machining, and so on.

  9. Coupling Measurements in ATF2 Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Rimbault, Cecile; /Orsay, LAL; Kuroda, Shigeru; /KEK, Tsukuba; Tauchi, Toshiaki; /KEK, Tsukuba; Terunuma, Nobuhiro; /KEK, Tsukuba; White, Glen; /SLAC; Woodley, Mark; /SLAC

    2012-06-29

    The purpose of ATF2 is to deliver a beam with stable very small spotsizes as required for future linear colliders such as ILC or CLIC. To achieve that, precise controls of aberrations such as dispersion and coupling are necessary. Theoretically, the complete reconstruction of the beam matrix is possible from the measurements of horizontal, vertical and tilted beam sizes, combining skew quadrupole scans at several wire-scanner positions. Such measurements were performed in the extraction line (EXT) of ATF2 in May 2009. We present analysis results attempting to resolve the 4 x 4 beam matrix. We aimed to reconstruct the full beam matrix using only skew quadrupole scans at different EXT wire-scanner locations, with measurements of horizontal, vertical and two tilted beam size projections. Checking the coherence of the {sigma}{sub 13} reconstruction from the {sigma}{sub 80{sup o}} and the {sigma}{sub 100{sup o}} measurements was essential to perform this analysis. We have shown that reconstruction of the coupling element can not be performed independantly of the 4 x 4 diagonal ones since it leads to unphysical results. A more accurate and automatisable method was find, leading to physical beam matrix reconstruction, compatible with the measurements. Another analysis should be performed based on a larger number of data sets to minimise statistical errors.

  10. FFAG Beam Line for nuPIL - Neutrinos from PIon Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, Jean-Baptiste [Fermilab; Pasternak, Jaroslaw [Rutherford; Bross, Alan [Fermilab; Liu, Ao [Fermilab; Appleby, Robert [Cockcroft Inst. Accel. Sci. Tech.; Tygier, Sam [Cockcroft Inst. Accel. Sci. Tech.

    2016-06-01

    The Long Baseline Neutrino Facilities (LBNF) program aims to deliver a neutrino beam for the Deep Underground Neutrino Experiment (DUNE). The current baseline for LBNF is a conventional magnetic horn and decay pipe system. Neutrinos from PIon beam Line (nuPIL) is a part of the optimization effort to optimize the LBNF. It consists of a pion beam line after the horn to clean the beam of high energy protons and wrong-sign pions before transporting them into a decay beam line, where instrumentation could be implemented. This paper focuses on the FFAG solution for this pion beam line. The resulting neutrino flux is also presented.

  11. Design and Performance of the CNGS Secondary Beam Line

    CERN Document Server

    Gschwendtner, E; Elsener, K; Ferrari, A; Guglielmi, A; Meddahi, M; Pardons, A; Rangod, Stephane; Sala, P

    2007-01-01

    An intense muon-neutrino beam (1017nm /day) is generated at CERN and directed towards the Gran Sasso National Laboratory, LNGS, in Italy, 732 km away from CERN. In the presently approved physics programme, it is foreseen to run the CNGS facility with 4.5.1019 protons per year for five years. During a nominal CNGS cycle, i.e. every 6s, two nominal SPS extractions of 2.4.1013 protons each at 400GeV/c are sent down the proton beam line to the target. The CNGS secondary beam line, starting with the target, has to cope with this situation, which pushes the beam line equipment and instrumentation to the limits of radiation hardness and mechanical stresses during the CNGS operation. An overview of the CNGS secondary beam line is given. Emphasis is on the target, the magnetic focusing lenses (horn and reflector) and the muon monitors. The performance of the secondary beam line during beam commissioning and physics operation is discussed and measurements are compared with simulations.

  12. Multi turn beam extraction from synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, Nicholaos

    2017-01-24

    This disclosure relates to apparatuses and methods for the extraction of particle beams while maintaining the energy levels and precision of the particles and the particle beam. Apparatuses and methods for extracting a charged particle beam from a central orbit in a synchrotron are provided, in which a particle beam is deflected from the central orbit. Parts of the deflected particle beam passes through a stripping foil placed in at least parts of the deflected path such that the particles that pass through the foil are stripped of at least one electron. The electron stripped particles and the non-stripped particles may be separated magnetically.

  13. Beamline for schools beam line training day

    CERN Multimedia

    Photo Service, CERN

    2014-01-01

    The first two teams to participate in CERN's Beamline for Schools project spent their second day at CERN learning the basics of beam physics, and visiting their experimental setup at the T9 beam line in CERN's East Hall on the Meyrin site.

  14. Beam line for Schools: beyond expectations

    CERN Multimedia

    Cian O'Luanaigh

    2014-01-01

    Out of 292 proposals for CERN's first ever "Beam line for Schools" contest, two teams of high-school students – Odysseus' Comrades from Varvakios Pilot School in Athens, Greece and Dominicuscollege from Dominicus College in Nijmegen in the Netherlands – were selected to spend 10 days conducting their proposed experiments at the fully equipped T9 beam line on CERN's Meyrin site. Dedicated CERN staff and users from across the departments have put in a huge effort to ensure the success of the project.   Detector physicist Cenk Yidriz (centre, white helmet) explains the setup of the "Beamline for schools" experiment at the T9 beamline. It's finally beam time. After months of organisation, coding, engineering and even painting the experimental area, the T9 beam line is ready to deliver protons to experiments devised and built by high-school students. “They are here to collect data and experience the l...

  15. Simulating the Beam-line at CERN's ISOLDE Experiment

    CERN Document Server

    McGrath, Casey

    2013-01-01

    Maximizing the optical matching along portions of the ISOLDE beam-line and automating this procedure will make it easier for scientists to determine what the strengths of the electrical elds of each beam-line element should be in order to reduce particle loss. Simulations are run using a program called MAD-X, however, certain issues were discovered that hindered an immediate success of the simulations. Specifically, the transfer matrices for electrostatic components like the switchyards, kickers, and electric quadrupoles were missing from the original coding. The primary aim of this project was to design these components using AutoCAD and then extract the transfer matrices using SIMION. Future work will then implement these transfer matrices into the MAD-X code to make the simulations of the beam-line more accurate.

  16. Current status of HESYRL lithography beam line

    Science.gov (United States)

    Qian, Shinan; Li, Guihe; Liu, Zewen; Chen, Qianhong; Jiang, Dikui; kan, Ya; Liu, Wanpo

    1990-06-01

    A lithography beam line, as the first of possibly six or more, has been installed in the Hefei Synchrotron Radiation Laboratory (HESYRL). A scanning mirror is used to cut off shorter wavelengths and to expand exposure dimensions vertically. The scanning mirror is oscillated by a stepping motor while an in-situ Moirè fringe grating system measures motor speed uniformity. Some testing results are given. In the first part of the beam line, there is a beryllium window to block longer wavelength light, a laser alignment unit to align the beam line and a special exposure shutter, which is controlled by another stepping motor. An exposure chamber with vacuum of 5 × 10-7 torr is located 7 meters downstream from the source point. Because there is no window at the entrance of the chamber, a differential pumping system is needed. The chamber is equipped with a mask-wafer system, driven by a third stepping motor.

  17. Generate Uniform Transverse Distributed Electron Beam along a Beam Line

    CERN Document Server

    Jiao, Y

    2015-01-01

    It has been reported that transverse distribution shaping can help to further enhance the energy extraction efficiency in a terawatt, tapered X-ray free-electron laser. Thus, methods of creating and keeping almost uniform transverse distributed (UTD) beam within undulators are required. This study shows that a UTD electron beam can be generated within evenly distributed drift sections where undulators can be placed, by means of octupoles and particular optics. A concrete design is presented, and numerical simulations are done to verify the proposed method.

  18. The role of space charge compensation for ion beam extraction and ion beam transport (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Spädtke, Peter, E-mail: p.spaedtke@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung GmbH (Germany)

    2014-02-15

    Depending on the specific type of ion source, the ion beam is extracted either from an electrode surface or from a plasma. There is always an interface between the (almost) space charge compensated ion source plasma, and the extraction region in which the full space charge is influencing the ion beam itself. After extraction, the ion beam is to be transported towards an accelerating structure in most cases. For lower intensities, this transport can be done without space charge compensation. However, if space charge is not negligible, the positive charge of the ion beam will attract electrons, which will compensate the space charge, at least partially. The final degree of Space Charge Compensation (SCC) will depend on different properties, like the ratio of generation rate of secondary particles and their loss rate, or the fact whether the ion beam is pulsed or continuous. In sections of the beam line, where the ion beam is drifting, a pure electrostatic plasma will develop, whereas in magnetic elements, these space charge compensating electrons become magnetized. The transport section will provide a series of different plasma conditions with different properties. Different measurement tools to investigate the degree of space charge compensation will be described, as well as computational methods for the simulation of ion beams with partial space charge compensation.

  19. Extraction design and low energy beam transport optimization of space charge dominated multispecies ion beam sources

    Science.gov (United States)

    Delferrière, O.; De Menezes, D.

    2004-05-01

    In all accelerator projects, the low energy part of the accelerator has to be carefully optimized to match the beam characteristic requirements of the higher energy parts. Since 1994 with the beginning of the Injector of Protons for High Intensity (IPHI) project and Source of Light Ions with High Intensities (SILHI) electron cyclotron resonance (ECR) ion source development at CEA/Saclay, we are using a set of two-dimensional (2D) codes for extraction system optimization (AXCEL, OPERA-2D) and beam transport (MULTIPART). The 95 keV SILHI extraction system optimization has largely increased the extracted current, and improved the beam line transmission. From these good results, a 130 mA D+ extraction system for the International Fusion Material Irradiation Facility project has been designed in the same way as SILHI one. We are also now involved in the SPIRAL 2 project for the building of a 40 keV D+ ECR ion source, continuously tunable from 0.1 to 5 mA, for which a special four-electrode extraction system has been studied. In this article we will describe the 2D design process and present the different extraction geometries and beam characteristics. Simulation results of SILHI H+ beam emittance will be compared with experimental measurements.

  20. Study of Abnormal Vertical Emittance Growth in ATF Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Alabau, M.; Faus-Golfe, A.; /Valencia U., IFIC; Alabau, M.; Bambade, P.; Brossard, J.; Le Meur, G.; Rimbault, C.; Touze, F.; /Orsay, LAL; Angal-Kalinin, D.; Jones, J.K.; /Daresbury; Appleby, R.; Scarfe, A.; /Manchester U.; Kuroda, S.; /KEK, Tsukuba; White, G.R.; Woodley, M.; /SLAC; Zimmermann, F.; /CERN

    2011-11-04

    Since several years, the vertical beam emittance measured in the Extraction Line (EXT) of the Accelerator Test Facility (ATF) at KEK, that will transport the electron beam from the ATF Damping Ring (DR) to the future ATF2 Final Focus beam line, is significantly larger than the emittance measured in the DR itself, and there are indications that it grows rapidly with increasing beam intensity. This longstanding problem has motivated studies of possible sources of this anomalous emittance growth. One possible contribution is non-linear magnetic fields in the extraction region experimented by the beam while passing off-axis through magnets of the DR during the extraction process. In this paper, simulations of the emittance growth are presented and compared to observations. These simulations include the effects of predicted non-linear field errors in the shared DR magnets and orbit displacements from the reference orbit in the extraction region. Results of recent measurements using closed orbit bumps to probe the relation between the extraction trajectory and the anomalous emittance growth are also presented.

  1. Negative ion beam extraction in ROBIN

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Gourab, E-mail: bansal@ipr.res.in [Institute for Plasma Research (IPR), Bhat, Gandhinagar, Gujarat 382428 (India); Gahlaut, Agrajit; Soni, Jignesh; Pandya, Kaushal; Parmar, Kanu G.; Pandey, Ravi; Vuppugalla, Mahesh; Prajapati, Bhavesh; Patel, Amee; Mistery, Hiren [Institute for Plasma Research (IPR), Bhat, Gandhinagar, Gujarat 382428 (India); Chakraborty, Arun; Bandyopadhyay, Mainak; Singh, Mahendrajit J.; Phukan, Arindam; Yadav, Ratnakar K.; Parmar, Deepak [ITER-India, Institute for Plasma Research, A-29, Sector 25, GIDC, Gandhinagar, Gujarat 380025 (India)

    2013-10-15

    Highlights: ► A RF based negative hydrogen ion beam test bed has been set up at IPR, India. ► Ion source has been successfully commissioned and three campaigns of plasma production have been carried out. ► Extraction system (35 kV) has been installed and commissioning has been initiated. Negative ion beam extraction is immediate milestone. -- Abstract: The RF based single driver −ve ion source experiment test bed ROBIN (Replica Of BATMAN like source in INDIA) has been set up at Institute for Plasma Research (IPR), India in a technical collaboration with IPP, Garching, Germany. A hydrogen plasma of density 5 × 10{sup 12} cm{sup −3} is expected in driver region of ROBIN by launching 100 kW RF power into the driver by 1 MHz RF generator. The cesiated source is expected to deliver a hydrogen negative ion beam of 10 A at 35 kV with a current density of 35 mA/cm{sup 2} as observed in BATMAN. In first phase operation of the ROBIN ion source, a hydrogen plasma has been successfully generated (without extraction system) by coupling 80 kW RF input power through a matching network with high power factor (cos θ > 0.8) and different plasma parameters have been measured using Langmuir probes and emission spectroscopy. The plasma density of 2.5 × 10{sup 11} cm{sup −3} has been measured in the extraction region of ROBIN. For negative hydrogen ion beam extraction in second phase operation, extraction system has been assembled and installed with ion source on the vacuum vessel. The source shall be first operated in volume mode for negative ion beam extraction. The commissioning of the source with high voltage power supply has been initiated.

  2. ILC Extraction Line for 14 mrad Crossing Angle

    Energy Technology Data Exchange (ETDEWEB)

    Nosochkov, Y.; Markiewicz, T.; Maruyama, T.; Seryi, A.; /SLAC; Parker, B.; /Brookhaven

    2005-12-08

    The earlier studies of the ILC extraction line for 20 mrad and 2 mrad crossing angle options [1]-[5] showed that the 20 mrad design has an advantage of a simpler beamline and lower extraction beam loss because of the independent incoming and extraction optics. However, the large 20 mrad crossing angle requires the use of a crab cavity correction, increases synchrotron radiation emittance growth in the solenoid, and increases photon backscattering from the forward calorimeter of the detector. To reduce these effects, an attempt has been made to minimize the crossing angle while keeping the extraction and incoming lines separate. A new quadrupole scheme near the interaction point has been proposed which allows a reduction of the crossing angle to 14 mrad [6]. The optics design and results of tracking and background simulations for the 14 mrad extraction line are presented.

  3. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fraction...... of the generated ions. The ion extractor is surrounded by a space charge (810) formed at least in part by the extracted ions. The ion extractor includes a biased electrode (806) forming an interface with an insulator (808). The interface is customized to form a strongly curved potential distribution (812......) in the space-charge surrounding the ion extractor. The strongly curved potential distribution focuses the extracted ions towards an opening (814) on a surface of the biased electrode thereby resulting in an ion beam....

  4. A Line Extraction Algorithm for Hand Drawings

    Institute of Scientific and Technical Information of China (English)

    赵明

    1995-01-01

    This paper presents an algorithm for extracting lines from hand drawings.It starts from contour pixel tracing,fits them into contour segments,and then extracts skeleton lines from the contour segments.The algorithm finds all contours in one scan of the input matrix without detecting and marking multiple pixels.In line extraction,the method Elastic Contour Segment Tracing is proposed which extracts lines by referring to the contour segments at both sides,overcoming noise and passing through blotted areas by fitting and extrapolation. Experiments on free hand mechanical drawings,sketches,letter/numerals,as well as Chinese characters are carried out and satisfactory results are achieved.

  5. Implementation of EPICS based Control System for Radioisotope Beam line

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    Korea Mult-purpose Accelerator Complex (KOMAC) has been operating 100 MeV proton linear accelerator . For operating 100 MeV linac, various control system has been implemented such as vacuum, power supply, RCCS and etc. KOMAC is operating two beam lines so that clients can use 100 MeV proton beam for their experiment. KOMAC sends beam to beam line and target room using two dipole magnets and several quadrupole magnets. As demand for experiments and Radius Isotope using beam is increased, another beam line is under construction and RI beam line control system is need. To synchronize with KOMAC control system, RI beam line control system is based on Experimental Physics and Industrial control System (EPICS) software. The beam is transported to RI beam line to control magnet power supply and vacuum. Implementation of RI beam line control system is presented and some preliminary results are reported. The base RI beam line control system is implemented. It can control beam direction and vacuum. Comparing archived data and current data, RI beam line and control system will be improved. In the future, scroll pump and gate control system will be implemented using programmable logic controller PLC. RI beam interlock sequence will be added to KOMAC interlock system to protect linac.

  6. High spin isomer beam line at RIKEN

    Energy Technology Data Exchange (ETDEWEB)

    Kishida, T.; Ideguchi, E.; Wu, H.Y. [Institute of Physical and Chemical Research, Saitama (Japan)] [and others

    1996-12-31

    Nuclear high spin states have been the subject of extensive experimental and theoretical studies. For the production of high spin states, fusion reactions are usually used. The orbital angular momentum brought in the reaction is changed into the nuclear spin of the compound nucleus. However, the maximum induced angular momentum is limited in this mechanism by the maximum impact parameter of the fusion reaction and by the competition with fission reactions. It is, therefore, difficult to populate very high spin states, and as a result, large {gamma}-detector arrays have been developed in order to detect subtle signals from such very high spin states. The use of high spin isomers in the fusion reactions can break this limitation because the high spin isomers have their intrinsic angular momentum, which can bring the additional angular momentum without increasing the excitation energy. There are two methods to use the high spin isomers for secondary reactions: the use of the high spin isomers as a target and that as a beam. A high spin isomer target has already been developed and used for several experiments. But this method has an inevitable shortcoming that only {open_quotes}long-lived{close_quotes} isomers can be used for a target: {sup 178}Hf{sup m2} (16{sup +}) with a half-life of 31 years in the present case. By developing a high spin isomer beam, the authors can utilize various short-lived isomers with a short half-life around 1 {mu}s. The high spin isomer beam line of RIKEN Accelerator Facility is a unique apparatus in the world which provides a high spin isomer as a secondary beam. The combination of fusion-evaporation reaction and inverse kinematics are used to produce high spin isomer beams; in particular, the adoption of `inverse kinematics` is essential to use short-lived isomers as a beam.

  7. Radioactive ion beam line in Lanzhou

    Institute of Scientific and Technical Information of China (English)

    詹文龙; 郭忠言; 刘冠华; 党建荣; 何锐荣; 周嗣信; 尹全民; 罗亦孝; 王义芳; 魏宝文; 孙志宇; 肖国青; 王金川; 江山红; 李加兴; 孟祥伟; 张万生; 秦礼军; 王全进

    1999-01-01

    Radioactive ion beam line in Lanzhou (RIBLL) has been constructed for the production of short-lived radioactive nuclei and studies of exotic nuclei far from the β-stability line. It has been put into operation recently at the National Laboratory of Heavy Ion Accelerator Lanzhou. RIBLL consists of two doubly achromatic parts with a solid acceptance ΔΩ≥6.5 msr, momentum acceptance Δp/p=±5% and maximum magnetic rigidity Bρmax=4.2 Tm. The second part of RIBLL serving as a spectrometer gives an element resolution Z/ΔZ>150 and mass resolution A/ΔA>300. The polarized secondary beams can be obtained by using a swinger dipole magnet to change the incident direction of primary projectile from 0°to 5°. The shortest lift time for secondary beams on RIBLL is less than 1μs. First experiments were performed with neutron rich nuclei for understanding the properties of halo nuclei and exotic nuclear reactions.

  8. RESULTS FROM THE COMMISSIONING OF THE NSRL BEAM TRANSFER LINE AT BNL.

    Energy Technology Data Exchange (ETDEWEB)

    TSOUPAS,N.; BELLAVIA,S.; BONATI,R.; ET AL.

    2004-07-05

    The NASA SPACE RADIATION LABORATORY (NSRL) has been constructed and started operations at the Brookhaven National Laboratory in 2003. The NSRL facility will be used by NASA to perform radiation effect studies on materials and biological samples for the space program. The facility utilizes proton and heavy-ion beams of energies from 50 to 3000 MeVln which are accelerated by the AGS Booster synchrotron accelerator. To date, {sup 1}H, {sup 12}C, {sup 56}Fe, {sup 48}Ti, and {sup 197}Au ion beams of various magnetic rigidities have been extracted from the Booster, and transported by the NSRL beam transport line to the sample location which is located 100 m from the extraction point. The NSRL beam transport line has been designed to employ octupole magnetic elements which transform the normal (Gaussian) beam distribution at the location of the sample into a beam with rectangular cross section, and uniformly distributed over the sample. When using the octupole magnetic elements to obtain the uniform beam distribution on the sample, no beam-collimation is applied at any location along the NSRL beam transport line and the beam focusing on the sample is purely magnetic. The main subject of this paper will be the performance of the octupoles (third order optics) in obtaining uniform beam distributions at the target of the NSRL beam transport line.

  9. Time profile of the slowly extracted beam

    CERN Document Server

    Pullia, M

    1997-01-01

    An important spin-off from accelerators is the use of synchrotrons for cancer therapy. For this application a precise control of the slow extraction is needed to satisfy the medical specifications for the online measurement and control of the delivered dose. This has led to a renewed interest in the basic theory of third-order resonance extraction. In the present paper, an analytic study of the time profile of the extracted beam is made by first considering the time profile of an elementary strip of monoenergetic particles from the side of the shrinking stable triangle. This basic result is then used to predict the characteristics of the spills for the most common extraction configurations. The influence of ripples whose period is comparable to the transit time of a particle in the resonance is also analyzed. Simulations of the extraction process that confirm the analytic study are included.

  10. Synthesis of Beam Lines with Necessary Properties

    CERN Document Server

    Andrianov, Serge

    2005-01-01

    In this paper a new approach to the problem of synthesis of beam lines is discussed. Usually this problem can be overcome by the use of numerical simulation and optimal control theory methods. But this results in sufficiently great number of variable parameters and functions. Obviously, that this degrades quality of a modeling procedure. The suggested approach is demonstrated on a problem of a microprobe design problem. Essence of the problem is that necessary to design a high precision focusing system which satisfies some additional conditions. For solution of this problem we use an algebraic treatment based on Lie algebraic methods and computer algebra techniques. Using the symmetry ideology this approach allows rewriting beam properties to enough simple conditions for control parameters and functions. This leads a set of desired solutions and show results in some most suitable form. Moreover, this approach decreases the number of variable parameters.

  11. Concept for ELENA Extraction and Beam Transfer Elements

    CERN Document Server

    Borburgh, J; Balhan, B; Barna, D; Bartmann, W; Fowler, T; Pricop, V; Sermeus, L; Vanbavinckhove, G

    2013-01-01

    In 2011 the ELENA decelerator was approved as a CERN project. Initially one extraction was foreseen, which should use a kicker and a magnetic septum which can be recuperated from an earlier installation. Since then a second extraction has been approved and a new solution was studied using only electric fields to extract the beam. This will be achieved by fast pulsing a separator, allowing single-bunch but also a full single-turn extraction from ELENA towards the experiments. The extraction and transfer requirements of ELENA are described, followed by the principal differences between the magnetic and electric field concepts. The design of electrostatic focussing and bending devices for the transfer lines will be presented. Finally the field quality which can be achieved with the separator and the concept of its power supply will be discussed.

  12. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Science.gov (United States)

    Zhang, Xu; Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming; Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN-LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  13. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xu, E-mail: emmazhang103@gmail.com [China Institute of Atomic Energy (China); Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming [China Institute of Atomic Energy (China); Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir [BEST Cyclotron Inc (Canada)

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN–LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  14. Beam Line: 100 years of elementary particles

    Science.gov (United States)

    Pais, A.; Weinberg, S.; Quigg, C.; Riordan, M.; Panofsky, W. K. H.

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  15. Multi-transmission-line-beam interactive system

    Energy Technology Data Exchange (ETDEWEB)

    Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

    2013-11-15

    We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

  16. The Beam Position System of the CERN Neutrino to Gran Sasso Proton Beam Line

    CERN Document Server

    Bogey, T

    2008-01-01

    The CERN Neutrino to Gran Sasso (CNGS) experiment uses 400GeV protons extracted from the SPS, which travel along 825 meters of beam line before reaching the CNGS target. This beam line is equipped with 23 BPMs capable of measuring both the horizontal and vertical position of the beam. The final BPM is linked to the target station and due to radiation constraints has been designed to work in air. This contribution will give an overview of the BPMs used in the transfer line. It will also provide a detailed explanation of their logarithmic amplifier based acquisition electronics, which consists of an autotriggered sequencer controlling an integrator, the A/D conversion and the Manchester encoded transmission of the digital data to the surface. At the surface the digital data is acquired using the Digital Acquisition Board (DAB) developed by TRIUMF (Canada) for the LHC BPM system. Results from both laboratory measurements and beam measurements during the 2006 CNGS run will also be presented.

  17. MARS Tracking Simulations for the Mu2e Slow Extracted Proton Beam

    Energy Technology Data Exchange (ETDEWEB)

    Nagaslaev, Vladimir [Fermilab; Rakhno, Igor [Fermilab

    2015-06-01

    Particle tracking taking into account interactions with fields and materials is necessary for proper evaluation of the resonant extraction losses and geometry optimization for the extraction beam line. This paper describes the tracking simulations for the Mu2e Resonant Extraction and discusses the geometry choices made based on these simulations.

  18. Losses in the Post-Collision Extraction Line

    CERN Document Server

    Salt, M D; Elsener, K; Ferrari, A

    2010-01-01

    The CLIC beam delivery system focuses 1.5 TeV electron and positron beams to a nanometre-sized cross section when colliding them at the interaction point (IP). The intense focusing leads to large beam-beam effects, causing the production of beamstrahlung photons, coherent and incoherent e+e− pairs, as well as a significant disruption of the main beam. The transport of the post-collision beams requires a minimal loss extraction line, with high acceptance for energy deviation and divergence. The current design includes vertical bends close to the IP in order to separate the charged particles with a sign opposite to the main beam into a diagnostic-equipped intermediate dump, whilst transporting the photons and the main beam to the final dump. Photon and charged particle losses on magnet masks and dumps result in a complex radiation field and IP background particle fluxes. In this paper, the electromagnetic backgrounds at the IP arising from the losses occurring closest to the collision point are calculated.

  19. Analysis of transmission efficiency of SSRF electron beam transfer lines

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this article, the main factors which influence transmission efficiency of the SSRF electron beam transfer lines are described, including physical requirements for magnet system, vacuum system, beam diagnostic system,trajectory correction system, etc. The dynamic simulation calculation and transmission efficiency analysis of the SSRF electron beam transfer lines are presented, and the studies show that the design purpose of efficient beam transmission and injection will be achieved.

  20. Straw man 900-1000 GeV crystal extraction test beam for Fermilab collider operation

    Energy Technology Data Exchange (ETDEWEB)

    Carrigan, R.A. Jr.

    1996-10-01

    A design for a 900-1000 GeV, 100 khz parasitic test beam for use during collider operations has been developed. The beam makes use of two bent crystals, one for extraction and the other one for redirecting the beam in to the present Switchyard beam system. The beam requires only a few modifications in the A0 area and largely uses existing devices. It should be straight-forward to modify one or two beam lines in the fixed target experimental areas to work above 800 GeV. Possibilities for improvements to the design,to operate at higher fluxes are discussed.

  1. Beam Transfer Line Design for a Plasma Wakefield Acceleration Experiment (AWAKE) at the CERN SPS

    CERN Document Server

    Bracco, C; Brethoux, D; Clerc, V; Goddard, B; Gschwendtner, E; Jensen, L K; Kosmicki, A; Le Godec, G; Meddahi, M; Muggli, P; Mutin, C; Osborne, O; Papastergiou, K; Pardons, A; Velotti, F M; Vincke, H

    2013-01-01

    The world’s first proton driven plasma wakefield acceleration experiment (AWAKE) is presently being studied at CERN. The experimentwill use a high energy proton beam extracted from the SPS as driver. Two possible locations for installing the AWAKE facility were considered: the West Area and the CNGS beam line. The previous transfer line from the SPS to the West Area was completely dismantled in 2005 and would need to be fully re-designed and re-built. For this option, geometric constraints for radiation protection reasons would limit the maximum proton beam energy to 300 GeV. The existing CNGS line could be used by applying only minor changes to the lattice for the final focusing and the interface between the proton beam and the laser, required for plasma ionisation and bunch-modulation seeding. The beam line design studies performed for the two options are presented.

  2. Automated Beam Loss Monitoring System At Extraction From U-70

    CERN Document Server

    Afonin, A G; Baranov, V T; Gres, V N; Shaposhnikov, P A; Terekhov, V I; Uglekov, V Ya

    2004-01-01

    This paper presents a description of the new beam loss monitoring system built and comissioned to detect beam losses in the IHEP extraction area at 16 places of interest. It yields information about possible beam interception by extraction elements over each mode of extracting. Multiple measurements with resolution 10ms are possible to study the dynamic processes over the slow extraction. This system is a part of the U-70 Control System.

  3. LHC beam dumping system Extraction channel layout and acceptance

    CERN Document Server

    Goddard, B; Uythoven, J; Veness, R; Weterings, W

    2003-01-01

    The LHC beam dumping system must safely abort the LHC beams under all conditions, including those resulting from abnormal behaviour of machine elements or subsystems of the beam dumping system itself. The extraction channels must provide sufficient aperture both for the circulating and extracted beams, over the whole energy range and under various beam parameters. These requirements impose tight constraints on the tolerances of various extraction channel components, and also on the allowed range of beam positions in the region of these components. Operation of the beam dumping system under various fault states has been considered, and the resulting apertures calculated. After describing briefly the beam dumping system and the extraction channel geometry, the various assumptions made in the analysis are presented, before deriving tolerance limits for the relevant equipment and beam parameters.

  4. Upgrades to the SPS-to-LHC Transfer Line Beam Stoppers for the LHC High-Luminosity Era

    CERN Document Server

    Kain, Verena; Fraser, Matthew; Goddard, Brennan; Meddahi, Malika; Perillo Marcone, Antonio; Steele, Genevieve; Velotti, Francesco

    2016-01-01

    Each of the 3 km long transfer lines between the SPS and the LHC is equipped with two beam stoppers (TEDs), one at the beginning of the line and one close to the LHC injection point, which need to absorb the full transferred beam. The beam stoppers are used for setting up the SPS extractions and transfer lines with beam without having to inject into the LHC. Energy deposition and thermo-mechanical simulations have, however, shown that the TEDs will not be robust enough to safely absorb the high intensity beams foreseen for the high-luminosity LHC era. This paper will summarize the simulation results and limitations for upgrading the beam stoppers. An outline of the hardware upgrade strategy for the TEDs together with modifications to the SPS extraction interlock system to enforce intensity limitations for beam on the beam stoppers will be given.

  5. Micron-scale laser-wire scanner for the KEK Accelerator Test Facility extraction line

    Science.gov (United States)

    Boogert, Stewart T.; Blair, Grahame A.; Boorman, Gary; Bosco, Alessio; Deacon, Lawrence C.; Karataev, Pavel; Aryshev, Alexander; Fukuda, Masafumi; Terunuma, Nobihiro; Urakawa, Junji; Corner, Laura; Delerue, Nicolas; Foster, Brian; Howell, David; Newman, Myriam; Senanayake, Rohan; Walczak, Roman; Ganaway, Fred

    2010-12-01

    A laser-wire transverse electron beam size measurement system has been constructed and operated at the Accelerator Test Facility (ATF) extraction line at KEK. The construction of the system is described in detail along with the environment of the ATF related to the laser wire. A special set of electron beam optics was developed to generate an approximately 1μm vertical focus at the laser-wire location. The results of our operation at the ATF extraction line are presented, where a minimum rms electron beam size of 4.8±0.3μm was measured, and smaller electron beam sizes can be measured by developing the method further. The beam size at the laser-wire location was changed using quadrupoles and the resulting electron beam size measured, and vertical emittance extracted.

  6. Micron-scale laser-wire scanner for the KEK Accelerator Test Facility extraction line

    Directory of Open Access Journals (Sweden)

    Stewart T. Boogert

    2010-12-01

    Full Text Available A laser-wire transverse electron beam size measurement system has been constructed and operated at the Accelerator Test Facility (ATF extraction line at KEK. The construction of the system is described in detail along with the environment of the ATF related to the laser wire. A special set of electron beam optics was developed to generate an approximately 1  μm vertical focus at the laser-wire location. The results of our operation at the ATF extraction line are presented, where a minimum rms electron beam size of 4.8±0.3  μm was measured, and smaller electron beam sizes can be measured by developing the method further. The beam size at the laser-wire location was changed using quadrupoles and the resulting electron beam size measured, and vertical emittance extracted.

  7. Enhancing the accelerated beam current in the booster synchrotron by optimizing the transport line beam propagation

    Indian Academy of Sciences (India)

    Saini R S; Tyagi Y; Ghodke A D; Puntambekar T A

    2016-04-01

    In this paper, we present the results of transverse beam emittance and twiss parameter measurement of an electron beam, delivered by a 20 MeV microtron which is used as a pre-injector system for a booster synchrotron in the Indus Accelerator Facility at RRCAT Indore. Based on these measured beam parameters, beam optics of a transport line was optimized and its results are alsodiscussed in this paper. This beam transport line is used to transport the electron beam from the 20MeV microtron to the booster synchrotron. The booster synchrotron works as a main injector for Indus-1 and Indus-2 synchrotron radiation facilities. To optimize the beam optics of a transport linefor proper beam transmission through the line as well as to match the beam twiss parameters at the beam injection point of another accelerator, it is necessary to know the transverse beam emittance and twiss parameters of the beam coming from the first one. A MATLAB-based GUI program has been developed to calculate the beam emittance and twiss parameters, using quadrupole scanmethod. The measured parameters have been used for beam transport line optimization and twiss parameters matching at booster injection point. After this optimization, an enhancement of ∼50% beam current has been observed in the booster synchrotron.

  8. Effects of Magnet Errors in the ILC 14 mrad Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Toprek, Dragan; /VINCA Inst. Nucl. Sci., Belgrade; Nosochkov, Yuri; /SLAC

    2009-05-08

    The ILC baseline extraction line is designed for 14 mrad horizontal crossing angle between e{sup +} and e{sup -} colliding beams at Interaction Point (IP). The extraction optics in the Interaction Region (IR) includes a detector integrated dipole field (anti-DID) to reduce orbit perturbation caused by the detector solenoid and minimize detector background. This paper presents a study of random field and alignment errors in the extraction magnets, compensation of the induced orbit perturbation, and effects of errors on extraction beam power loss. The results are obtained for the baseline ILC energy of 500 GeV center-of-mass and three options of beam parameters.

  9. Energy compensation of slow extracted beams with RF acceleration

    Science.gov (United States)

    Fujimoto, Tetsuya; Souda, Hikaru; Torikoshi, Masami; Kanai, Tatsuaki; Yamada, Satoru; Noda, Koji

    2016-03-01

    In a conventional carbon-ion radiotherapy facility, a carbon-ion beam is typically accelerated up to an optimum energy, slowly extracted from a synchrotron ring by a resonant slow extraction method, and ultimately delivered to a patient through a beam-delivery system. At Japan's Gunma University, a method employing slow-beam extraction along with beam-acceleration has been adopted. This method slightly alters the extracted-beam's energy owing to the acceleration component of the process, which subsequently results in a residual-range variation of approximately 2 mm in water-equivalent length. However, this range variation does not disturb a distal dose distribution with broad-beam methods such as the single beam-wobbling method. With the pencil-beam 3D scanning method, however, such a range variation disturbs a distal dose distribution because the variation is comparable to slice thickness. Therefore, for pencil-beam 3D scanning, an energy compensation method for a slow extracted beam is proposed in this paper. This method can compensate for the aforementioned energy variances by controlling net energy losses through a rotatable energy absorber set fixed between the synchrotron exit channel and the isocenter. Experimental results demonstrate that beam energies can be maintained constant, as originally hypothesized. Moreover, energy-absorber positions were found to be significantly enhanced by optimizing beam optics for reducing beam-size growth by implementation of the multiple-scattering effect option.

  10. Neutralization principles for the Extraction and Transport of Ion Beams

    CERN Document Server

    Riege, H

    2000-01-01

    The strict application of conventional extraction techniques of ion beams from a plasma source is characterized by a natural intensity limit determined by space charge.The extracted current may be enhanced far beyond this limit by neutralizing the space charge of the extracted ions in the first extraction gap of the source with electrons injected from the opposite side. The transverse and longitudinal emittances of a neutralized ion beam, hence its brightness, are preserved. Results of beam compensation experiments, which have been carried out with a laser ion source, are resumed for proposing a general scheme of neutralizing ion sources and their adjacent low-energy beam transport channels with electron beams. Many technical applications of high-mass ion beam neutralization technology may be identified: the enhancement of ion source output for injection into high-intensity, low-and high-energy accelerators, or ion thrusters in space technology, for the neutral beams needed for plasma heating of magnetic conf...

  11. Muon Beam Studies in the H4 beam line and the Gamma Irradiation Facility (GIF++)

    CERN Document Server

    Margraf, Rachel; CERN. Geneva. EN Department

    2017-01-01

    In this report, I summarize my work of detailed study and optimization of the muon beam configuration of H4 beam line in SPS North Area. Using Monte-Carlo simulations, I studied the properties and behavior of the muon beam in combination with the field of the large, spectrometer “ GOLIATH” magnet at -1.5, -1.0, 0, 1.0 and 1.5 Tesla, which is shown to affect the central x position of the muon beam that is delivered to the Gamma Irradiation Facility (GIF++). I also studied the muon beam for different configurations of the two XTDV beam dumps upstream of GIF++ in the H4 beam line. I will also discuss my role in mapping the magnetic field of the GOLIATH magnet in the H4 beam line.

  12. Beam coupling impedances of fast transmission-line kickers.

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey)

    2002-01-01

    Fast transmission-line kickers contain no ferrite and consist of two long metallic parallel plates supported by insulators inside a beam pipe. A beam is deflected by both the electric and magnetic fields of a TEM wave created by a pulse propagating along the strips in the direction opposite to the beam. Computations of the beam coupling impedances for such structures are difficult because of their length. In the paper, the beam coupling impedances of transmission-line kickers are calculated by combining analytical and numerical methods: the wake potentials computed in short models are extended analytically to obtain the wakes for the long kickers, and then the corresponding beam impedances are derived. At very low frequencies the results are compared with simple analytical expressions for the coupling impedances of striplines in beam position monitors.

  13. Neutrinos from PIon Beam Line, nuPIL

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, J. B. [Imperial Coll., London; Pasternak, J. [Imperial Coll., London; Bross, A. [Fermilab; Liu, A. [Fermilab

    2016-05-05

    LBNF-DUNE (Long Baseline Neutrino Facilities - Deep Underground Neutrino Experiment) is a project based at Fermilab to study neutrino oscillations. The current baseline regarding the neutrino production considers the conventional approach: a high energy proton beam hits a target, producing pions that are collected by a horn and that decay in a decay pipe. An alternative solution, called nuPIL (neutrinos from a Pion beam Line) consists of using a beam line to guide the pions to clean the beam and to put instrumentation to monitor it. This paper presents the concept and the first preliminary results.

  14. Radiation Shielding Design for ISOL System Beam Line

    Institute of Scientific and Technical Information of China (English)

    WANG; Feng; QIN; Jiu-chang

    2013-01-01

    The beam line of the ISOL system passes through the shielding wall and connects the HI-13 tandem accelerator.Neutron produced by tandem accelerator will affect the area of BRIF through the beam line.To protect the staff in BRIF area from radiation a shielding design of the beam line is carried out.The neutron source in the vault of tandem accelerator is the H.E Faraday cup of HI-13 tandem accelerator as showed in Fig.1.The Faraday cup is consisted of 1 mm molybdenum sheet and 10 mm

  15. On-Line Bunch Tomography and Beam Modelling for MTE Commissioning

    CERN Document Server

    Rothe, Johannes

    2015-01-01

    For my stay as a CERN Summer Student from June 29 to September 25, 2015, I worked with Guido Sterbini of the Accelerator and Beam Physics group. I was based in the CERN Control Center (CCC) at the Prevessin Site, and supported the ongoing beam commissioning work on Multi-Turn Extraction through the development of on-line monitoring and control tools for the Proton Synchrotron (PS) machine.

  16. New Beam Profile Monitoring System At Extraction From U-70

    CERN Document Server

    Afonin, A G; Gorlov, V N; Gres, V N; Sokolov, S V; Terekhov, V I

    2004-01-01

    In the course of upgrading Instrumentation of extracted beams at IHEP the new beam profile monitoring system has been developed and comissioned. It incorporates many improvements towards lower amount of monitor substance to be placed in the beam path, lower cable expenses, higher radiation and noisy resistance, wider dynamic range. New circuitry allows one to measure profiles separately for each extraction in one machine cycle. The system has a capability for multiple measures of beam profile during the slow extraction for exploring dynamic effects. The paper describes hardware and software of system.

  17. Emittance Measurements For Future LHC Beams Using The PS Booster Measurement Line

    CERN Document Server

    Abelleira, Jose; Mikulec, Bettina; Di Giovanni, Gian Piero; CERN. Geneva. ATS Department

    2017-01-01

    The CERN PS Booster measurement line contains three pairs of SEM grids separated by drift space that measures the beam size in both planes. The combined analysis of these grids allows calculating a value for the transverse beam emittances. The precision of such a measurement depends on the ratio of RMS beam size and wire spacing. Within the LIU-PSB upgrade the extraction kinetic energy of the PSB will be increased from the current 1.4 GeV to 2.0 GeV. This will result in smaller transverse beam sizes for some of the future beams. The present layout of the transverse emittance measurement line is reviewed to verify if it will satisfy future requirements.

  18. Magnet Design for the ISIS Second Target Station Proton Beam Line

    CERN Document Server

    Thomas, Chris; Jago, Stephen

    2005-01-01

    The ISIS facility, based at the Rutherford Appleton Laboratory in the UK, is an intense source of neutrons and muons for condensed matter research. The accelerator facility delivers an 800 MeV proton beam of 2.5x1013 protons per pulse at 50 Hz to the present target station. As part of a facility upgrade, it is planned to share the source with a second, 10 Hz, target station. The beam line supplying this target will extract from the existing target station beam line. Electromagnetic Finite Element Modelling techniques have been used to design the magnets required to meet the specified beam line optics. Kicker, septum, dipole, quadrupole, and steering magnets are covered. The magnet design process, involving 2D and 3D modelling, the calculation of ideal shims and chamfers, choice of steel, design of conducting coils, handling of heating issues and eddy current effects, is discussed.

  19. Alignment Sensitivity Study of the St. ANA Beam Line

    Science.gov (United States)

    Gervais, Michelle; Couder, Manoel; Jung, Hyo Soon; Setoodehnia, Kiana

    2014-09-01

    The St. ANA (STable Accelerator for Nuclear Astrophysics) accelerator is being prepared for use with the St. George recoil mass separator. The accelerator is in working condition for use in direct kinematic experiments but the St. George separator works with inverse kinematics and requires a highly controlled beam restricted by severe position and divergence parameters that are not achieved at the present time. A systematic sensitivity study was conducted using a simulation of the beam line in order to assess the impact of a misalignment in each optical element or in the beam itself. Tests were done with the beam to analyze how the beam behaves at various points in the line and to compare this data with simulation results to determine possible causes of misalignment. The results of these tests and simulations are that the beam characteristics are now better understood and the possible causes of the limitations have been narrowed down. The St. ANA (STable Accelerator for Nuclear Astrophysics) accelerator is being prepared for use with the St. George recoil mass separator. The accelerator is in working condition for use in direct kinematic experiments but the St. George separator works with inverse kinematics and requires a highly controlled beam restricted by severe position and divergence parameters that are not achieved at the present time. A systematic sensitivity study was conducted using a simulation of the beam line in order to assess the impact of a misalignment in each optical element or in the beam itself. Tests were done with the beam to analyze how the beam behaves at various points in the line and to compare this data with simulation results to determine possible causes of misalignment. The results of these tests and simulations are that the beam characteristics are now better understood and the possible causes of the limitations have been narrowed down. Project advisor

  20. The SPS beam lines to the West Hall

    CERN Multimedia

    1976-01-01

    The proton beam arriving from bottom is cut into three parts by the special steel septum magnets, seen in the centre, and then focussed onto the targets just out the sight on the top. The beam line near the right hand wall carries an RF-separated beam to BEBC from a target located deep in the TT60 tunnel. (Annual Report 1976 p. 116)

  1. Improvements and developments on radioactive ion beam line in Lanzhou

    CERN Document Server

    Guo Zhong Yan; Xiao Guo Qing; Xu Hu Shan; Sun Zhi Yu; Li Jia Xing; Wang Meng; Chen Zhi Qiang; Mao Rui Shi; Wang Wu Sheng; Bai Jie; Hu Zheng Guo; Chen Li Xin; Li Chen

    2003-01-01

    The improvements and the developments on radioactive ion beam line in Lanzhou (RIBLL) were carried out. So the performances of RIBLL are toned up evidently. It makes operating and setting RIBLL convenient and reliable

  2. Simulation of ion beam extraction and focusing system

    Institute of Scientific and Technical Information of China (English)

    B.A.Soliman; M.M.Abdelrahman; A.G.Helal; F.W.Abdelsalam

    2011-01-01

    The characteristics of ion beam extraction and focused to a volume as small as possible were investigated with the aid of computer code SIMION 3D version 7.This has been used to evaluate the extraction characteristics(accel-decel system)to generate an ion beam with low beam emittance and high brightness.The simulation process can provide a good study for optimizing the extraction and focusing system of the ion beam without any losses and transported to the required target.Also,a study of a simulation model for the extraction system of the ion source was used to describe the possible plasma boundary curvatures during the ion extraction that may be affected by the change in an extraction potential with a constant plasma density meniscus.

  3. Micron Size Laser-Wire System at the ATF Extraction Line, Recent Results and ATF-II Upgrade

    CERN Document Server

    Blair, G A; Boorman, G; Bosco, A; Deacon, L; Karataev, P; Howell, D; Nevay, L J; Corner, L; Delerue, N; Foster, B; Gannaway, F; Newman, M; Senanayake, R; Walczak, R; Hayano, H; Aryshev, A; Terunuma, N; Urakawa, J

    2010-01-01

    The KEK Accelerator test facility (ATF) extraction line laser-wire system has been upgraded last year allowing the measurement of micron scale transverse size electron beams. The most recent measurements using the upgraded system are presented. The ATF-II extraction line design call for the major upgrade of the existing laser-wire system. We report on the hardware upgrades, including the major hardware upgrades to the laser transport, the laser beam diagnostics line, and the mechanical control systems.

  4. Snake beam: a paraxial arbitrary focal line

    OpenAIRE

    Rosen, Joseph; Yariv, Amnon

    1995-01-01

    The creation of paraxial arbitrary focal lines by a Fourier computer-generated hologram is demonstrated. The desired focal line is represented by a series of connected straight line segments, each of which is implemented by a radial harmonic function located on a different radial portion of the entire hologram. Each subhologram is multiplied by appropriate linear and quadratic phase functions and is shifted by some distance from the center. The two phase factors determine the location of each...

  5. Beam Coupling Impedances of Traveling-Wave Ferrite-Free Extraction Kickers

    Science.gov (United States)

    Kurennoy, Sergey

    2002-04-01

    Fast traveling-wave extraction kickers contain no ferrite and consist of two long metallic parallel plates supported by insulators inside a beam pipe. A beam is deflected by both the electric and magnetic fields of a TEM wave created by a pulse propagating along the strips in the direction opposite to the beam. Computations of the beam coupling impedances for such structures are difficult because of their length. In the paper, the beam coupling impedances of such transmission-line kickers are calculated by combining analytical and numerical methods: the wake potentials computed in short models are extended analytically to obtain the wakes for the long kickers, and then the corresponding beam impedances are derived. As one can expect, at very low frequencies the results are in agreement with simple analytical expressions available for the coupling impedances of striplines in beam position monitors.

  6. Development of a low-energy, high-brightness $\\mu^+$ beam line

    CERN Document Server

    Eggenberger, A; Wichmann, G

    2016-01-01

    We are developing a beam line which compresses the phase space of a standard surface $\\mu^+$ beam by 10 orders of magnitude with an efficiency of $10^{-3}$. Phase space compression occurs in a He gas target and consists of three consecutive stages: Transverse (perpendicular to the beam axis) compression, longitudinal compression and re-extraction into vacuum. Transverse compression was observed for the first time and longitudinal compression has been measured to occur within 2.5 $\\mu$s with high efficiency.

  7. R&D of the Fluoroscopes of 100 MeV Cyclotron Beam Lines

    Institute of Scientific and Technical Information of China (English)

    YIN; Meng; GUAN; Feng-ping; XIE; Huai-dong; ZHENG; Xia; XING; Jian-sheng; LV; Yin-long

    2013-01-01

    Beijing Radioactive Ion-beam Facility(BRIF)consists of a 100 MeV H-cyclotron CYCIAE-100and nine beam lines.All the beam lines provide the channels of the proton beam or the neutron beam to the terminal of physics experiment.There are many beam diagnosis monitors distributing along the beam lines,including,Faraday cups,beam position monitors,fluoroscopes,collimators,emittance measurement

  8. An electromagnetically focused electron beam line source

    Science.gov (United States)

    Iqbal, Munawar; Masood, Khalid; Rafiq, Mohammad; Chaudhary, Maqbool A.; Aleem, Fazal-e.-

    2003-11-01

    A directly heated thermionic electron beam source was constructed. A tungsten wire of length 140 mm with diameter 0.9 mm was used as a cathode. An emission current of 5000 mA was achieved at an input heating power of 600 W. Cathode to anode distance of 6 mm with acceleration voltage of 10 kV was used. A uniform external magnetic field of 50 G was employed to obtain a well-focused electron beam at a deflection of 180°, with cathode to work site distance of 130 mm. Dimensions of the beam (1.25×120 mm) recorded at the work site were found to be in good agreement with the designed length of cathode. The deformation of the cathode was overcome by introducing a spring action mechanism, which gives uniform emission current density throughout the emission surface. We have achieved the saturation limit of the designed source resulting in smooth and swift operation of the gun for many hours (10-15 h continuously). The design of gun is so simple that it can accommodate longer cathodes for obtaining higher emission values. This gun has made it possible to coat large substrate surfaces at much faster evaporation rate at lower cost. It can also be useful in large-scale vacuum metallurgy plants for melting, welding and heat treatment.

  9. Turn-By Beam Extraction during Acceleration in a Synchrotron

    Science.gov (United States)

    Tsoupas, Nicholaos; Trbojevic, Dejan

    2014-02-01

    A synchrotron to accelerate protons or carbon ions for medical applications is being designed at Brookhaven National Laboratory (BNL). Single beam bunches with maximum beam energy of 1.18 GeV and 400 MeV/u for protons and carbon ions respectively will be extracted from the synchrotron at 15 Hz. For protons, the maximum required energy for irradiating a tumor is ˜206 MeV. A pencil-like proton beam containing ˜5.4×107 p/bunch delivers a therapeutic dose of 2.5 Gy in ˜1.5 minutes to treat a tumor of 1 liter volume. It will take ˜80 minutes with bunches containing 4.5×104 ions/bunch to deliver the same dose of 2.5 Gy with a 400 MeV/u pencil-like carbon beam. This extended treatment time when using carbon ions is not acceptable. In addition, the synchrotron cannot be controlled with a beam bunch containing such a low number of carbon ions. To overcome these two problems of the extended treatment time and the low bunch intensity required for the treatment when carbon ions are used, we have devised a method to “peel” the required 4.5×104 carbon-ions/bunch from the accelerating carbon beam bunch containing ˜108 ions/bunch and deliver them to the tumor on a “turn-by-turn” basis. Unlike other methods of beam extraction from a synchrotron, such as resonance extraction, this method does not allow for any beam losses during the extraction and the carbon beam can be peeled off in less than 15 ms during the acceleration or deceleration cycle of the synchrotron. Thus, this turn-by-turn beam extraction method provides beam with variable energy and precisely controlled beam current during the 30 ms acceleration or deceleration time.

  10. Materials research and beam line operation utilizing NSLS. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Liedl, G.L.

    1993-06-01

    MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year all 232 operational days were fully utilized. Beam line tests coupled with MATRIX members combined to use 284 days. General user demand for use of the beam line continues to be strong and four groups were provided 48 operating days. Research production has been growing as NSLS and the beam line become a more stable type of operation. For 1992 the MATRIX group published six articles. To date, for 1993 the same group has published, submitted, or has in preparation nine articles. Recent research milestones include: the first quantitative structural information on the as-quenched and early stages of decomposition of supersaturated Al-Li alloys; the first quantitative diffuse scattering measurements on a complex system (Co substitute for Cu YBCO superconductor); demonstration of capabilities of a new UHV surface diffraction chamber with in-situ characterization and temperature control (30-1300K); feasibility of phasing structure factors in a quasicrystal using multiple Bragg scattering.

  11. Beam Diagnostics Instrumentation for the High Energy Beam Transport Line of I.P.H.I.

    CERN Document Server

    Ausset, P; Coacolo, J L; Lesrel, J; Maymon, J N; Olivier, A; Rouviere, N; Solal-Cohen, M; Vatrinet, L; Yaniche, J F

    2005-01-01

    I.P.H.I. is a High Intensity Proton Injector under construction at Saclay (C.N.R.S/ I.N.2P.3; C.E.A. / D.A.P.N.I.A and C.E.R.N. collaboration). An E.C.R. produces a 100 keV, 100 mA C.W. proton beam which will be accelerated at 3 MeV by a 4 vanes R.F.Q. operating at 352.2 MHz. Finally, a High Energy Beam Transport Line (H.E.B.T.) will deliver the beam to a beam stopper and will be equipped with appropriate beam diagnostics to carry intensity; centroïd beam transverse position, transverse beam profiles, beam energy and energy spread measurements for the commissioning of I.P.H.I. These beam diagnostics will operate under both pulsed and C.W. operation. Transverse beam profile measurements will be acquired under low and high duty factor pulsed beam operation using a slow wire scanner and a C.C.D. camera to image the beam-induced fluorescence. The beam instrumentation of the H.E.B.T. is reviewed and preliminary obtained transverse profile measurements at 100 keV are described.

  12. Beam diagnostics instrumentation for the high energy beam transfer line of I.P.H.I

    Energy Technology Data Exchange (ETDEWEB)

    Ausset, P.; Berthelot, S.; Coacolo, J.L.; Lesrel, J.; Maymon, J.N.; Olivier, A.; Rouviere, N.; Solal, M.; Vatrinet, L.; Yaniche, J.F. [Institut de Physique Nucleaire, (IN2P3/CNRS) 91 - Orsay (France); Belyaev, G.; Roudskoy, I. [I.T.E.P. Moscow (Russian Federation)

    2005-07-01

    I.P.H.I. is a High Intensity Proton Injector under construction at Saclay. An E.C.R. source produces a 100 keV, 100 mA C.W. proton beam which will be accelerated at 3 MeV by a 4 vanes R.F.Q. operating at 352.2 MHz. Finally, a High Energy Beam Transport Line (H.E.B.T.) will deliver the beam to a beam stopper and will be equipped with appropriate beam diagnostics to carry intensity, centroid beam transverse position, transverse beam profiles, beam energy and energy spread measurements for the commissioning of I.P.H.I. These beam diagnostics will operate under both pulsed and C.W. operation. Transverse beam profile measurements will be acquired under low and high duty factor pulsed beam operation using a slow wire scanner and a C.C.D. camera to image the beam-induced fluorescence. The beam instrumentation of the H.E.B.T. is reviewed and preliminary obtained transverse profile measurements at 100 keV are described. (authors)

  13. A beam optics study of the biomedical beam line at a proton therapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Chong Cheoul [National Center for Inter-University Research Facilities, Seoul National University, Sillim-dong, Gwanak, Seoul (Korea, Republic of); Kim, Jong-Won [Research Institute and Hospital, National Cancer Center, 809 Madu-dong, Ilsan-gu, Koyang, Kyonggi 410 769 (Korea, Republic of)], E-mail: jwkim@ncc.re.kr

    2007-10-15

    A biomedical beam line has been designed for the experimental area of a proton therapy facility to deliver mm to sub-mm size beams in the energy range of 20-50 MeV using the TRANSPORT/TURTLE beam optics codes and a newly-written program. The proton therapy facility is equipped with a 230 MeV fixed-energy cyclotron and an energy selection system based on a degrader and slits, so that beam currents available for therapy decrease at lower energies in the therapeutic beam energy range of 70-230 MeV. The new beam line system is composed of an energy-degrader, two slits, and three quadrupole magnets. The minimum beam sizes achievable at the focal point are estimated for the two energies of 50 and 20 MeV. The focused FWHM beam size is approximately 0.3 mm with an expected beam current of 20 pA when the beam energy is reduced to 50 MeV from 100 MeV, and roughly 0.8 mm with a current of 10 pA for a 20 MeV beam.

  14. Simulation of ion beam injection and extraction in an EBIS

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, L., E-mail: zhao@far-tech.com; Kim, J. S. [FAR-TECH, Inc., San Diego, California 92121 (United States)

    2016-02-15

    An example simulation of Au+ charge breeding using FAR-TECH’s integrated EBIS (electron beam ion source) modeling toolset is presented with the emphasis on ion beam injection and extraction. The trajectories of injected ions are calculated with PBGUNS (particle beam gun simulation) self-consistently by including the space charges from both ions and electrons. The ion beam, starting with initial conditions within the 100% acceptance of the electron beam, is then tracked by EBIS-PIC (particle-in-cell EBIS simulation code). In the trap, the evolution of the ion charge state distribution is estimated by charge state estimator. The extraction of charge bred ions is simulated with PBGUNS. The simulations of the ion injections show significant ion space charge effects on beam capture efficiency and the ionization efficiency.

  15. Simulation of ion beam injection and extraction in an EBIS

    Science.gov (United States)

    Zhao, L.; Kim, J. S.

    2016-02-01

    An example simulation of Au+ charge breeding using FAR-TECH's integrated EBIS (electron beam ion source) modeling toolset is presented with the emphasis on ion beam injection and extraction. The trajectories of injected ions are calculated with PBGUNS (particle beam gun simulation) self-consistently by including the space charges from both ions and electrons. The ion beam, starting with initial conditions within the 100% acceptance of the electron beam, is then tracked by EBIS-PIC (particle-in-cell EBIS simulation code). In the trap, the evolution of the ion charge state distribution is estimated by charge state estimator. The extraction of charge bred ions is simulated with PBGUNS. The simulations of the ion injections show significant ion space charge effects on beam capture efficiency and the ionization efficiency.

  16. 1. 5 GeV/c multiturn shaving extraction and its transport line for the Brookhaven AGS

    Energy Technology Data Exchange (ETDEWEB)

    Weng, W.T.; Blumberg, L.N.; Gill, E.; Soukas, A.; Witkover, R.L.; Egleman, E.; LoSecco, J.; Sulak, L.

    1979-01-01

    A system for fast shaving extraction at 1.5 GeV/c is implemented to extract the circulating beam in five turns. A numerical simulation is first carried out to determine the emittance and the rf structure of the extracted beam. This is followed by several machine study sessions which establish the optimal extraction configuration, confirm the emittance, and modify the transport line for low energy beam. Finally, a one-week run for the Neutrino Oscillation experiment demonstrates that the system is very stable and capable of delivering 7.5 x 10/sup 12/ p/sec with 70% extraction efficiency and 95% transport efficiency.

  17. Collimator for the SPS extracted beam

    CERN Multimedia

    1976-01-01

    This is a water cooled copper collimator (TCSA) which has exactly the shape of the cross section of the downstream magnetic beam splitter. Parts of the blown up primary proton beam pass above/below and left through this collimator. A small part of the protons is absorbed in the thin copper wedges. In this way the downstream magnetic splitter of the same cross section receives already a beam where its magnetic wedges are no longer hit by protons. The upstream, water cooled collimator, more resistant to protons, has cast a 'shadow' onto the downstream magnetic splitter, less resistant to protons. Gualtero Del Torre stands on the left.

  18. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  19. On-line laser spectroscopy with thermal atomic beams

    CERN Document Server

    Thibault, C; De Saint-Simon, M; Duong, H T; Guimbal, P; Huber, G; Jacquinot, P; Juncar, P; Klapisch, Robert; Liberman, S; Pesnelle, A; Pillet, P; Pinard, J; Serre, J M; Touchard, F; Vialle, J L

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a CW tunable dye laser interacts at right angles with a thermal atomic beam. /sup 76-98/Rb, /sup 118-145 /Cs and /sup 208-213/Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while /sup 30-31/Na and /sup 38-47/K have been studied by setting the apparatus directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. The hyperfine structure, spins and isotope shifts of the alkali isotopes and isomers are measured. (8 refs).

  20. Beam lines from Linac 1 to PS and Booster

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    View against the direction of the proton beams. The 50 MeV Linac 1 is behind the concrete wall. Its beam emerges from the hole near the centre of the picture. A switching magnet directs the beam either to the PS (to the right in the sense of the beam; original injection line), or lets it go straight on to the Booster (originally 800 MeV, now 1.4 GeV). The huge drum in the line to the Booster is a "debuncher", driven by the 200 MHz RF of the linac. It reduces the beam's momentum spread. This was the last year of Linac 1 as provider of protons to the Booster. Linac 2, nearly completed at the time of this picture, took up trial delivery at the end of 1978, and routine delivery in 1979. The beam line from Linac 2, barely visible here, can be clearly seen on 7802260. Linac 1 had a second life as an ion accelerator.

  1. FIRST BEAM TESTS OF THE MUON COLLIDER TARGET TEST BEAM LINE AT THE AGS.

    Energy Technology Data Exchange (ETDEWEB)

    BROWN,K.A.; GASSNER,D.; GLENN,J.W.; PRIGL,R.; SIMOS,N.; SCADUTO,J.; TSOUPAS,N.

    2001-06-18

    In this report we will describe the muon collider target test beam line which operates off one branch of the AGS switchyard. The muon collider target test facility is designed to allow a prototype muon collider target system to be developed and studied. The beam requirements for the facility are ambitious but feasible. The system is designed to accept bunched beams of intensities up to 1.6 x 10{sup 13} 24 GeV protons in a single bunch. The target specifications require beam spot sizes on the order of 1 mm, 1 sigma rms at the maximum intensity. We will describe the optics design, the instrumentation, and the shielding design. Results from the commissioning of the beam line will be shown.

  2. Power Losses in the ILC 20-Mrad Extraction Line at 1-TeV

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Arnaud; /Uppsala U.; Nosochkov, Yuri; /SLAC

    2007-07-02

    The authors have performed a detailed study of the power losses in the post-collision extraction line of a TeV e{sup +}e{sup -} collider with a crossing angle of 20 mrad at the interaction point. Five cases were considered: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam-beam effects at the interaction point lead to an emittance growth for the outgoing beam, as well as to the production of beamstrahlung photons and e{sup +}e{sup -} coherent pairs. The power losses along the extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular offset at the interaction point.

  3. Simulation of ion beam extraction and focusing system

    Institute of Scientific and Technical Information of China (English)

    B. A. Soliman; M. M. Abdelrahman; A. G. Helal; F. W. Abdelsalam

    2011-01-01

    The characteristics of ion beam extraction and focused to a volume as small as possible were investigated with the aid of computer code SIMION 3D version 7. This has been used to evaluate the extraction characteristics (accel-decel system) to generate an

  4. Confining continuous manipulations of accelerator beam-line optics

    Science.gov (United States)

    Amstutz, Ph.; Plath, T.; Ackermann, S.; Bödewadt, J.; Lechner, C.; Vogt, M.

    2017-04-01

    Altering the optics in one section of a linear accelerator beam line will in general cause an alteration of the optics in all downstream sections. In circular accelerators, changing the optical properties of any beam-line element will have an impact on the optical functions throughout the whole machine. In many cases, however, it is desirable to change the optics in a certain beam-line section without disturbing any other parts of the machine. Such a local optics manipulation can be achieved by adjusting a number of additional corrector magnets that restore the initial optics after the manipulated section. In that case, the effect of the manipulation is confined in the region between the manipulated and the correcting beam-line elements. Introducing a manipulation continuously, while the machine is operating, therefore requires continuous correction functions to be applied to the correcting quadrupole magnets. In this paper, we present an approach to calculate such continuous correction functions for six quadrupole magnets by means of a homotopy method. Besides a detailed derivation of the method, we present its application to an algebraic example, as well as its demonstration at the seeding experiment sFLASH at the free-electron laser FLASH located at DESY in Hamburg.

  5. Preliminary design of electrostatic sensors for MITICA beam line components

    Energy Technology Data Exchange (ETDEWEB)

    Spagnolo, S., E-mail: spagnolo@igi.cnr.it; Spolaore, M.; Dalla Palma, M.; Pasqualotto, R.; Sartori, E.; Serianni, G.; Veltri, P. [Consorzio RFX, Associazione EURATOM-ENEA sulla Fusione, 35127 Padova (Italy)

    2016-02-15

    Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

  6. Error analysis in post linac to driver linac transport beam line of RAON

    Science.gov (United States)

    Kim, Chanmi; Kim, Eun-San

    2016-07-01

    We investigated the effects of magnet errors in the beam transport line connecting the post linac to the driver linac (P2DT) in the Rare Isotope Accelerator in Korea (RAON). The P2DT beam line is bent by 180-degree to send the radioactive Isotope Separation On-line (ISOL) beams accelerated in Linac-3 to Linac-2. This beam line transports beams with multi-charge state 132Sn45,46,47. The P2DT beam line includes 42 quadrupole, 4 dipole and 10 sextupole magnets. We evaluate the effects of errors on the trajectory of the beam by using the TRACK code, which includes the translational and the rotational errors of the quadrupole, dipole and sextupole magnets in the beam line. The purpose of this error analysis is to reduce the rate of beam loss in the P2DT beam line. The distorted beam trajectories can be corrected by using six correctors and seven monitors.

  7. Monte Carlo Simulations of Beam Losses in the Test Beam Line of CTF3

    CERN Document Server

    Nebot Del Busto, E; Branger, E; Holzer, E B; Doebert, S; Lillestol, R L; Welsch, C P

    2013-01-01

    The Test Beam Line (TBL) of the CLIC Test Facility 3 (CTF3) aims to validate the drive beam deceleration concept of CLIC, in which the RF power requested to boost particles to multi-TeV energies is obtained via deceleration of a high current and low energy drive beam (DB). Despite a TBL beam energy (150-80 MeV) significantly lower than the minimum nominal energy of the CLIC DB (250 MeV), the pulse time structure of the TBL provides the opportunity to measure beam losses with CLIC-like DB timing conditions. In this contribution, a simulation study on the detection of beam losses along the TBL for the commissioning of the recently installed beam loss monitoring system is presented. The most likely loss locations during stable beam conditions are studied by considering the beam envelope defined by the FODO lattice as well as the emittance growth due to the deceleration process. Moreover, the optimization of potential detector locations is discussed. Several factors are considered, namely: the distance to the bea...

  8. G4beamline Particle Tracking in Matter Dominated Beam Lines

    Energy Technology Data Exchange (ETDEWEB)

    T.J. Roberts, K.B. Beard, S. Ahmed, D. Huang, D.M. Kaplan

    2011-03-01

    The G4beamline program is a useful and steadily improving tool to quickly and easily model beam lines and experimental equipment without user programming. It has both graphical and command-line user interfaces. Unlike most accelerator physics codes, it easily handles a wide range of materials and fields, being particularly well suited for the study of muon and neutrino facilities. As it is based on the Geant4 toolkit, G4beamline includes most of what is known about the interactions of particles with matter. We are continuing the development of G4beamline to facilitate its use by a larger set of beam line and accelerator developers. A major new feature is the calculation of space-charge effects. G4beamline is open source and freely available at http://g4beamline.muonsinc.com

  9. Laser-driven beam lines for delivering intensity modulated radiation therapy with particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, K. M.; Schell, S.; Wilkens, J. J. [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 München (Germany)

    2013-07-26

    Laser-accelerated particles can provide a promising opportunity for radiation therapy of cancer. Potential advantages arise from combining a compact, cost-efficient treatment unit with the physical advantages in dose delivery of charged particle beams. We consider different dose delivery schemes and the required devices to design a possible treatment unit. The secondary radiation produced in several beam line elements remains a challenge to be addressed.

  10. Test~of~Beam~Extraction~by~Crystal~Channeling~at~the~SPS: A First Step towards a LHC Extracted Beam

    CERN Multimedia

    2002-01-01

    % RD22 \\\\ \\\\ The availability of a beam extracted out of the LHC accelerator would open up very interesting possibilities for B-physics, in particular for the study of CP-violation. Channeling in bent crystals appears to be the most promising method to produce an extracted beam of intensity $\\sim$~10$^{8}$ p/sec. This would provide as many as 10$^{10}$ $ B \\bar{B} $ pairs per year of run, two orders of magnitude more than could be produced by an e$^+$e$^-$ B-factory with L~=~10$^{34}$ cm$^{-2}$s$^{-1}$ We propose a R\\&D program to study beam extraction at the CERN SPS, using a silicon bent crystal to be installed in the SPS beam pipe and placed next to the beam in such a way as to intercept the beam halo. Transverse excitation of the beam in presence of non-linearities will be used to create halo conditions similar to what are expected for LHC.

  11. Power production experiments at the Test Beam Line in the CLIC Test Facility 3

    CERN Document Server

    Lillestøl, Reidar Lunde; Adli, Erik; Lundheim, Lars Magne

    2010-01-01

    CLIC is an international study of a future multi-TeV electron-positron linear collider, where the energy of a high-intensity drive beam is extracted and transferred to the main beam via Power Extraction and Transfer Structures (PETS) in the form of rf power. The study of power production is therefore essential for the feasibility of CLIC. Power production in PETS has been studied, and ex- periments have been performed in the decelerator Test Beam Line in the CLIC Test Facility 3. In particular, the correlation of the power production and the beam position inside the structure has been studied. It is shown that the total produced power is constant when the beam has a position offset through the PETS. In addition, the difference between the measured phases from each side is independent of the beam position, which allows for efficient combination of the fields. However, the ratio of the power on each side of the PETS unexpectedly shows a linear dependence on the horizontal offset, with a correlation value of 0.8...

  12. Neutronics Assessments for a RIA Fragmentation Line Beam Dump Concept

    CERN Document Server

    Boles, Jason; Reyes, Susana; Stein, Werner

    2005-01-01

    Heavy ion and radiation transport calculations are in progress for conceptual beam dump designs for the fragmentation line of the proposed Rare Isotope Accelerator (RIA). Using the computer code PHITS, a preliminary design of a motor-driven rotating wheel beam dump and adjacent downstream multipole has been modeled. Selected results of these calculations are given, including neutron and proton flux in the wheel, absorbed dose and displacements per atom in the hub materials, and heating from prompt radiation and from decay heat in the multipole.

  13. Transfer line scattering model of therapeutic hadron beams and applications to nozzle and gantry optimization

    Science.gov (United States)

    Palm, M.; Benedikt, M.; Dorda, U.

    2013-01-01

    The field of hadron therapy is growing rapidly with several facilities currently being planned, under construction or in commissioning worldwide. In the “active scanning” irradiation technique, the target is irradiated using a narrow pencil beam that is scanned transversally over the target while the penetration depth is altered with the beam energy. Together, the target dose can thereby be conformed in all three dimensions to the shape of the tumor. For applications where a sharp lateral beam penumbra is required in order to spare critical organs from unwanted dose, beam size blowup due to scattering in on-line beam diagnostic monitors, air gaps and passive elements like the ripple filter must be minimized. This paper presents a model for transverse scattering of therapeutic hadron beams along arbitrary multislab geometries. The conventional scattering formulation, which is only applicable to a drift space, is extended to not only take beam optics into account, but also non-Gaussian transverse beam profiles which are typically obtained from the slow resonant extraction from a synchrotron. This work has been carried out during the design phase of the beam delivery system for MedAustron, an Austrian hadron therapy facility with first patient treatment planned for the end of 2015. Irradiation will be performed using active scanning with proton and carbon ion beams. As a direct application of the scattering model, design choices for the MedAustron proton gantry and treatment nozzles are evaluated with respect to the transverse beam profile at the focal point; in air and at the Bragg peak.

  14. Power losses in the international linear collider 20 mrad extraction line at 1 TeV

    Indian Academy of Sciences (India)

    A Ferrari; Yuri Nosochkov

    2007-11-01

    We have performed a detailed study of the power losses in the post-collision extraction line of a TeV + − collider with a crossing angle of 20 mrad at the interaction point. Five cases were considered: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam–beam effects at the interaction point lead to an emittance growth for the outgoing beam, as well as to the production of beamstrahlung photons and + − coherent pairs. The power losses along the extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular offset at the interaction point.

  15. Beam manipulation and acceleration with Dielectric-Lined Waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Lemery, Francois [Northern Illinois Univ., DeKalb, IL (United States)

    2015-06-01

    The development of next-generation TeV+ electron accelerators will require either immense footprints based on conventional acceleraton techniques or the development of new higher{gradient acceleration methods. One possible alternative is beam-driven acceleration in a high-impedance medium such as a dielectric-lined-waveguide (DLW), where a highcharge bunch passes through a DLW and can excite gradients on the order of GV/m. An important characteristic of this acceleration class is the transformer ratio which characterizes the energy transfer of the scheme. This dissertation discusses alternative methods to improve the transformer ratio for beam-driven acceleration and also considers the use of DLWs for beam manipulation at low energy.

  16. Physics at the new CERN neutron beam line

    CERN Document Server

    Guerrero, C

    2014-01-01

    A new neutron beam line (n_TOF EAR - 2) is being built at CERN within the n_TOF facility. Compared to the existing 185 meters long time - of - flight beam line, the new one (which will operate in parallel) will feature a shorter flight of 20 meters, providing a 2 7 times more intense neutron flux extending from thermal to 300 MeV. The scientific program is now bein g discussed and the first detailed proposals will be refereed by February 2014. This contribution is devoted to present and discuss the expected performance of the facility, briefly, and the details of some of the first measureme nts foreseen for 2014 and 2015.

  17. 3B1 beam line and its physical properties

    Science.gov (United States)

    Yi, Futing; Wang, Peiwei; Jin, Ming; Wu, Jianwu

    1995-02-01

    The 3B1 beam line is in the hall of 13# on BSRF, and is used for the lithography, biology and multilayer reflection research. On the line, there are a cylinder mirror system, a vacuum control system, an exposure chamber and a beryllium window for lithography research. The mirror coated with gold receives the synchrotron radiation at a glance angle of 1.5°, and scans in the vertical for lithography. The light, reflected by the scanning mirror and absorbed by the window, produces a spectrum of 4-20 Å and a uniformity spot for the lithography.

  18. Beam Line and Associated Work: Operational Phase 1985-1987

    Science.gov (United States)

    1988-08-26

    237 582-32 Optics for ineertion-devcs beam lines, V. Rehn. Michelson Lab. (invited Paper).............................. 238 582-35 The SSRL...University; Claudia Pellegrini, Brookhaven National Laboratory; Victor Rehn, Michelson Laboratory/U.S. Naval Weapons Center; R. P. Walker, SERC...moving through a bolted-together pair of Cu monoliths . Due to symmetry, the turning pro- cers yielded two mirrors, one of which is shown in Fig. 2. As is

  19. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    Science.gov (United States)

    Scisciò, M.; Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Papaphilippou, Y.; Antici, P.

    2016-03-01

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  20. Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

    Energy Technology Data Exchange (ETDEWEB)

    Scisciò, M.; Antici, P., E-mail: patrizio.antici@polytechnique.edu [INFN-RM1 and SBAI, Università di Roma “La Sapienza,” Via Scarpa 16, 00161 Roma (Italy); INRS-EMT, Université du Québec, 1650 Lionel Boulet, Varennes, Québec J3X 1S2 (Canada); Lancia, L.; Migliorati, M.; Mostacci, A.; Palumbo, L. [INFN-RM1 and SBAI, Università di Roma “La Sapienza,” Via Scarpa 16, 00161 Roma (Italy); Papaphilippou, Y. [CERN, CH 1211 Geneva 23 (Switzerland)

    2016-03-07

    In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

  1. Bending magnets for the CBA beam-transport line

    Energy Technology Data Exchange (ETDEWEB)

    Thern, R.E.

    1983-01-01

    The beam-transport line from the AGS to CBA requires 68 large bending magnets, consisting of pure dipoles and two types of combined function gradient magnets. All three types were designed with magnetic-field calculation program POISSON, using the same exterior dimensions and coil package. The design goal of +-1% momentum acceptance for the transport line required a wide horizontal aperture, with a much-smaller vertical aperture for economy. Two prototypes of one gradient magnet were built, and a facility constructed to measure them and the later production magnets. Measurements were done using both a long coil and a point coil (Rawson-Lush gaussmeter). Preliminary results show ..delta..B/B < 0.2 x 10/sup -3/, ..delta..G/G < 0.3 x 10/sup -2/, and ..delta..B/sub 2//B < 0.3 x 10/sup -4/ cm/sup -2/ over the beam aperture. Due to end effects, the actual gradient differs from the design gradient by 1%, which has been compensated for in the beam-line design.

  2. TANGO standard software to control the Nuclotron beam slow extraction

    Science.gov (United States)

    Andreev, V. A.; Volkov, V. I.; Gorbachev, E. V.; Isadov, V. A.; Kirichenko, A. E.; Romanov, S. V.; Sedykh, G. S.

    2016-09-01

    TANGO Controls is a basis of the NICA control system. The report describes the software which integrates the Nuclotron beam slow extraction subsystem into the TANGO system of NICA. Objects of control are power supplies for resonance lenses. The software consists of the subsystem device server, remote client and web-module for viewing the subsystem data.

  3. DESIGN OF BEAM-EXTRACTION SEPTUM MAGNET FOR THE SNS.

    Energy Technology Data Exchange (ETDEWEB)

    TSOUPAS,N.; LEE,Y.Y.; RANK,J.; TUOZZOLO,J.

    2001-06-18

    The beam-extraction process from the SNS accumulator ring [1,2] requires a Lambertson septum magnet. In this paper we discuss the geometrical and magnetic field requirements of the magnet and present results obtained from two and three dimensional magnetic field calculations that shows the field quality in the regions of interest of the septum magnet.

  4. Optimization of solenoid based low energy beam transport line for high current H+ beams

    Science.gov (United States)

    Pande, R.; Singh, P.; Rao, S. V. L. S.; Roy, S.; Krishnagopal, S.

    2015-02-01

    A 20 MeV, 30 mA CW proton linac is being developed at BARC, Mumbai. This linac will consist of an ECR ion source followed by a Radio Frequency Quadrupole (RFQ) and Drift tube Linac (DTL). The low energy beam transport (LEBT) line is used to match the beam from the ion source to the RFQ with minimum beam loss and increase in emittance. The LEBT is also used to eliminate the unwanted ions like H2+ and H3+ from entering the RFQ. In addition, space charge compensation is required for transportation of such high beam currents. All this requires careful design and optimization. Detailed beam dynamics simulations have been done to optimize the design of the LEBT using the Particle-in-cell code TRACEWIN. We find that with careful optimization it is possible to transport a 30 mA CW proton beam through the LEBT with 100% transmission and minimal emittance blow up, while at the same time suppressing unwanted species H2+ and H3+ to less than 3.3% of the total beam current.

  5. Characterization of a metastable neon beam extracted from a commercial RF ion source

    CERN Document Server

    Ohayon, B; Ron, G

    2015-01-01

    We have used a commercial RF ion-source to extract a beam of metastable neon atoms. The source was easily incorporated into our existing system and was operative within a day of installation. The metastable velocity distribution, flux, flow, and efficiency were investigated for different RF powers and pressures, and an optimum was found at a flux density of $2\\times10^{12}\\,$atoms/s/sr. To obtain an accurate measurement of the amount of metastable atoms leaving the source, we insert a Faraday cup in the beam line and quench some of them using a weak $633\\,$nm laser beam. In order to determine how much of the beam was quenched before reaching our detector, we devised a simple model for the quenching transition and investigated it for different laser powers. This detection method can be easily adapted to other noble gas atoms.

  6. Grid-controlled extraction of pulsed ion beams

    Science.gov (United States)

    Humphries, S., Jr.; Burkhart, C.; Coffey, S.; Cooper, G.; Len, L. K.; Savage, M.; Woodall, D. M.; Rutkowski, H.; Oona, H.; Shurter, R.

    1986-03-01

    Experimental results are presented on a method for extracting well-focused ion beams from plasma sources with time-varying properties. An electrostatic grid was used to stop the flow of plasma electrons so that only ions entered the extraction gap. In this case, ion flow in the gap was controlled by space-charge effects as it would be with a thermionic ion source. Constant extracted current was observed even with large variations of source flux. An insulator spark source and a metal-vapor vacuum arc were used to generate pulsed ion beams. With a hydrocarbon spark, current densities of 44 mA/cm2 were achieved at 20-kV extractor voltage for an 8-μs pulse. With an aluminum-vapor arc, a current density of 15 mA/cm2 (0.3 A total) was measured for a 50-μs pulse.

  7. Grid-controlled extraction of pulsed ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Humphries, S. Jr.; Burkhart, C.; Coffey, S.; Cooper, G.; Len, L.K.; Savage, M.; Woodall, D.M.; Rutkowski, H.; Oona, H.; Shurter, R.

    1986-03-15

    Experimental results are presented on a method for extracting well-focused ion beams from plasma sources with time-varying properties. An electrostatic grid was used to stop the flow of plasma electrons so that only ions entered the extraction gap. In this case, ion flow in the gap was controlled by space-charge effects as it would be with a thermionic ion source. Constant extracted current was observed even with large variations of source flux. An insulator spark source and a metal-vapor vacuum arc were used to generate pulsed ion beams. With a hydrocarbon spark, current densities of 44 mA/cm/sup 2/ were achieved at 20-kV extractor voltage for an 8-..mu..s pulse. With an aluminum-vapor arc, a current density of 15 mA/cm/sup 2/ (0.3 A total) was measured for a 50-..mu..s pulse.

  8. Automatic Railway Power Line Extraction Using Mobile Laser Scanning Data

    Science.gov (United States)

    Zhang, Shanxin; Wang, Cheng; Yang, Zhuang; Chen, Yiping; Li, Jonathan

    2016-06-01

    Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning) data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis) combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  9. Base Line Design for a Beta/Beam Neutrino Facility

    CERN Document Server

    Benedikt, Michael

    2004-01-01

    The term beta-beam has been coined for the production of pure beams of electron neutrinos or their antiparticles through the decay of radioactive ions circulating in a storage ring. The neutrino source itself consists of a high-energy storage ring (gamma ~150), with long straight sections in line with the experiment(s). The radioactive ions (6He and 18Ne) will be produced in an ISOL type target system. Due to the short life times of around 1 s at rest, the beam needs to be accelerated as quickly as possible. For this a staged system of accelerators is proposed. The chain starts with a linac followed by a rapid cycling synchrotron for acceleration up to ~300 MeV/u. For further acceleration the existing PS and SPS machines are used. Finally, after acceleration to SPS top energy, the ions are transferred to a decay ring where they are merged with the existing bunches through a longitudinal stacking procedure. The baseline design of the beta-beam facility will be presented together with its major problems. Potent...

  10. Possibility of high efficient beam extraction from the CERN SPS with a bent crystal. Simulation results

    Science.gov (United States)

    Scandale, W.; Kovalenko, A. D.; Taratin, A. M.

    2017-03-01

    The extraction of the SPS beam of 270 GeV/c protons assisted by a bent crystal was studied by simulation. Two methods for delivering the SPS beam onto a crystal were considered: transverse diffusion and orbit bump of the beam. It was shown that the main condition for high efficient beam extraction with a bent crystal, which is a small divergence of the incident beam, can be fulfilled. Extraction efficiency up to 99% can be reached for both methods of the beam delivering. The irradiation of the electrostatic septum wires during the beam extraction can be considerably reduced.

  11. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B. [Los Alamos National Laboratory, M. S. H808, Los Alamos, New Mexico 87545 (United States)

    1995-05-05

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  12. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Science.gov (United States)

    Gilpatrick, J. D.; Carter, H.; Plum, M.; Power, J. F.; Rose, C. R.; Shurter, R. B.

    1995-05-01

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  13. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B.

    1995-12-31

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  14. Efficient ion beam extraction from a flowing plasma

    Energy Technology Data Exchange (ETDEWEB)

    Dembinski, M.; John, P.K.

    1979-10-01

    A moving plasma with directed flow velocities v larger than the ion acoustic speed c/sub s/ is used as a source of high-current ion beams in the 10--20-keV range of energies. Current densities up to 3 A/cm/sup 2/ are obtained at the plasma boundary which is an order of magnitude larger than the limiting value of Bohm current in a stationary plasma. The observed current densities were proportional to v, unlike the Bohm current densities which are proportional to ion acoustic speed. Total ion currents up to approx.100 A were extracted from the plasma through a two electrode extraction system. Simple geometric shaping of the electrodes enabled an 8-cm-diam beam to be focused to approx.7 mm.

  15. The external proton beam lines and the splitter systems of the CERN SPS

    CERN Document Server

    Evans, Lyndon R; Ijspeert, Albert; de Raad, Bastiaan; Siegel, N; Weisse, E

    1977-01-01

    The exploitation of the CERN Super Proton Synchrotron (SPS) is based on two experimental areas, the West Area and the North Area. The West Area consists of the West Experimental Hall, fed by a slow ejected proton beam of 200 GeV/c maximum momentum and a Neutrino Facility which is fed by protons of 400 GeV/c. Several important detectors are installed in the West Area, the Omega spectrometer, the Big European Bubble Chamber and the heavy liquid bubble chamber Gargamelle. The North Area has been built for physics at 400 GeV/c. At present it consists of two experimental halls, a large multipurpose hall and a smaller hall dedicated to muon physics. The protons are extracted from the SPS in two of the six long straight sections (LSS) and are transported from the underground machine through a system of tunnels to the external targets. Both the beam lines to the West and North Area contain beam splitting stations which divide the slow extracted proton beam into three branches. (0 refs).

  16. The effects of beam line pressure on the beam quality of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V., E-mail: ville.toivanen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland); Steczkiewicz, O.; Tarvainen, O.; Ropponen, T.; Arje, J.; Koivisto, H. [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-05-01

    The results of a series of measurements studying the possibility to use neutral gas feeding into the beam line as a way to improve the quality of the heavy ion beams produced with an electron cyclotron resonance ion source (ECRIS) are presented. Significant reduction of the beam spot size and emittance can be achieved with this method. The observed effects are presumably due to increased space charge compensation degree of the ion beam in the beam line section between the ion source and the analyzing magnet. This is the region where the neutral gas was injected. It is shown that the effects are independent of the ion source tuning. Transmission measurements through the beam line and K-130 cyclotron have been carried out to study the effects of improved ion beam quality to the transmission efficiency.

  17. Extracting source parameters from beam monitors on a chopper spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Abernathy, Douglas L [ORNL; Niedziela, Jennifer L [ORNL; Stone, Matthew B [ORNL

    2015-01-01

    The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

  18. Development of BPM/BLM DAQ System for KOMAC Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Kim, Jae-Ha; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The proton beam is accelerated from 3 MeV to 100 MeV through 11 DTL tanks. The KOMAC installed 10 beam lines, 5 for 20-MeV beams and 5 for 100-MeV beams. The proton beam is transmitted to two target room. The KOMAC has been operating two beam lines, one for 20 MeV and one for 100 MeV. New beam line, RI beam line is under commissioning. A Data Acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. A data acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. The DAQ digitizes beam signal and the sampling is synchronized with a reference signal which is an external trigger for beam operation. The digitized data is accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. The beam monitoring system integrates BLM and BPM signals into the control system and offers realtime data to operators. The IOC, which is implemented with Linux and a PCI driver, supports data acquisition as a very flexible solution.

  19. Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following a beam line

    NARCIS (Netherlands)

    van Goethem, M. J.; van der Meer, R.; Reist, H. W.; Schippers, J. M.

    2009-01-01

    Monte Carlo simulations based on the Geant4 simulation toolkit were performed for the carbon wedge degrader used in the beam line at the Center of Proton Therapy of the Paul Scherrer Institute (PSI). The simulations are part of the beam line studies for the development and understanding of the GANTR

  20. Correction method for line extraction in vision measurement.

    Directory of Open Access Journals (Sweden)

    Mingwei Shao

    Full Text Available Over-exposure and perspective distortion are two of the main factors underlying inaccurate feature extraction. First, based on Steger's method, we propose a method for correcting curvilinear structures (lines extracted from over-exposed images. A new line model based on the Gaussian line profile is developed, and its description in the scale space is provided. The line position is analytically determined by the zero crossing of its first-order derivative, and the bias due to convolution with the normal Gaussian kernel function is eliminated on the basis of the related description. The model considers over-exposure features and is capable of detecting the line position in an over-exposed image. Simulations and experiments show that the proposed method is not significantly affected by the exposure level and is suitable for correcting lines extracted from an over-exposed image. In our experiments, the corrected result is found to be more precise than the uncorrected result by around 45.5%. Second, we analyze perspective distortion, which is inevitable during line extraction owing to the projective camera model. The perspective distortion can be rectified on the basis of the bias introduced as a function of related parameters. The properties of the proposed model and its application to vision measurement are discussed. In practice, the proposed model can be adopted to correct line extraction according to specific requirements by employing suitable parameters.

  1. Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, C.; Halama, H.; Thomlinson, W.

    1986-10-01

    Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

  2. 4D Emittance Measurements Using Multiple Wire and Waist Scan Methods in the ATF Extraction Line

    Energy Technology Data Exchange (ETDEWEB)

    Rimbault, C.; Bambade, P.; Brossard, J.; /Orsay, LAL; Alabau, M.; /Valencia U., IFIC; Kuroda, S.; /KEK, Tsukuba; Scarfe, A.; /Manchester U.; Woodley, M.; /SLAC

    2011-11-02

    Emittance measurements performed in the diagnostic section of the Accelerator Test Facility (ATF) extraction line since 1998 led to vertical emittances three times larger than the expected ones, with a strong dependence on intensity. An experimental program is pursued to investigate potential sources of emittance growth and find possible remedies. This requires efficient and reliable emittance measurement techniques. In the past, several phase-space reconstruction methods developed at SLAC and KEK have been used to estimate the vertical emittance, based on multiple location beam size measurements and dedicated quadrupole scans. These methods have been shown to be very sensitive to measurement errors and other fluctuations in the beam conditions. In this context new emittance measurements have been performed revisiting these methods and newly developed ones with a systematic approach to compare and characterise their performance in the ATF extraction line.

  3. Improved design of proton source and low energy beam transport line for European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Neri, L., E-mail: neri@lns.infn.it; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Ciavola, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Torrisi, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria dell’Informazione, delle Infrastrutture e dell’Energia Sostenibile, Università Mediterranea di Reggio Calabria, Via Graziella, 89122 Reggio Calabria (Italy); Cheymol, B.; Ponton, A. [European Spallation Source ESS AB, Lund (Sweden); Galatà, A. [Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Patti, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Gozzo, A.; Lega, L. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria Informatica e delle Telecomunicazioni, Università degli Studi di Catania, Viale Andrea Doria 6, 95123 Catania (Italy)

    2014-02-15

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  4. Improved design of proton source and low energy beam transport line for European Spallation Source

    Science.gov (United States)

    Neri, L.; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Torrisi, G.; Cheymol, B.; Ponton, A.; Galatà, A.; Patti, G.; Gozzo, A.; Lega, L.; Ciavola, G.

    2014-02-01

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  5. Extraction of line and rounded objects from underwater images

    Institute of Scientific and Technical Information of China (English)

    WANG Meng; YANG Jie; LIU Wei

    2006-01-01

    In the field of underwater image processing, the line and rounded objects, like mines and torpedoes, are the most common targets for recognition. Before further analysis, these two image patterns need to be detected and extracted from the underwater images in real-time. Using the subpixel position, direction and curvature information of an edge provided by Zernike Orthogonal Moment (ZOM) edge detection operators, an enhanced Randomized Hough Transform (RHT) to extract straight-lines is developed. This line extraction method consists of two steps: the rough parameters of a line are obtained robustly at first using RHT with large quantization in the Hough space and then the parameters are refined with line fitting techniques. Therefore both the robustness and high precision can be achieved simultaneously. Particularly, the problem of ellipse extraction is often computationally demanding using traditional Hough Transform, since an ellipse is characterized by five parameters. Based on the generalized K-RASAC algorithm, we develop a new ellipse extraction algorithm using the concept of quadratic curve cluster and random sampling technique. We first develop a new representation of quadratic curves, which facilitates quantization and voting for the parameter λ that represents a candidate ellipse among the quadratic curves. Then, after selecting two tangent points and calculating the quadratic parameter equation, we vote for the parameter λ to determine an ellipse. Thus the problem of ellipse extraction is reduced into finding the local minimum in the λ accumulator array. The methods presented have been applied successfully to the extraction of lines and ellipses from synthetic and real underwater images, serving as a basic computer vision module of the underwater objects recognition system. Compared to the standard RHT line extraction method and K-RANSAC ellipse extraction method, our methods have the attractive advantages of obtaining robustness and high precision

  6. Beam line shielding calculations for an Electron Accelerator Mo-99 production facility

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-03

    The purpose of this study is to evaluate the photon and neutron fields in and around the latest beam line design for the Mo-99 production facility. The radiation dose to the beam line components (quadrupoles, dipoles, beam stops and the linear accelerator) are calculated in the present report. The beam line design assumes placement of two cameras: infra red (IR) and optical transition radiation (OTR) for continuous monitoring of the beam spot on target during irradiation. The cameras will be placed off the beam axis offset in vertical direction. We explored typical shielding arrangements for the cameras and report the resulting neutron and photon dose fields.

  7. Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    CERN Document Server

    Pan, R; Lefevre, T; Gillepsie, WA; CERN. Geneva. ATS Department

    2015-01-01

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding(EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  8. The Nexawatt: A Strategy for Exawatt Peak Power Lasers Based on NIF and NIF-like Beam Lines

    Science.gov (United States)

    Barty, C. P. J.

    2016-05-01

    An exawatt-scale, short-pulse amplification architecture based upon a novel pulse compressor arrangement and amplification of long-duration chirped beam pulses is described. This architecture is capable of extracting the full, stored energy of a NIF or NIF-like beam line and in doing so produce from one beam line a near-diffraction-limited, laser pulse whose peak power would exceed 0.2 EW. The architecture is well suited to either low-f-number focusing or to multi-beam, dipole focusing concepts that in principle enable focused intensities in the range of 1026 W/cm2 or 5 orders of magnitude beyond that possible from present PW systems based on chirped pulse amplification.

  9. Extraction of Building Boundary Lines from Airborne LIDAR Point Clouds

    Science.gov (United States)

    Tseng, Yi-Hsing; Hung, Hsiao-Chu

    2016-10-01

    Building boundary lines are important spatial features that characterize the topographic maps and three-dimensional (3D) city models. Airborne LiDAR Point clouds provide adequate 3D spatial information for building boundary mapping. However, information of boundary features contained in point clouds is implicit. This study focuses on developing an automatic algorithm of building boundary line extraction from airborne LiDAR data. In an airborne LiDAR dataset, top surfaces of buildings, such as roofs, tend to have densely distributed points, but vertical surfaces, such as walls, usually have sparsely distributed points or even no points. The intersection lines of roof and wall planes are, therefore, not clearly defined in point clouds. This paper proposes a novel method to extract those boundary lines of building edges. The extracted line features can be used as fundamental data to generate topographic maps of 3D city model for an urban area. The proposed method includes two major process steps. The first step is to extract building boundary points from point clouds. Then the second step is followed to form building boundary line features based on the extracted boundary points. In this step, a line fitting algorithm is developed to improve the edge extraction from LiDAR data. Eight test objects, including 4 simple low buildings and 4 complicated tall buildings, were selected from the buildings in NCKU campus. The test results demonstrate the feasibility of the proposed method in extracting complicate building boundary lines. Some results which are not as good as expected suggest the need of further improvement of the method.

  10. Characterization of a tagged $\\gamma$-ray beam line at the DAFNE Beam Test Facility

    CERN Document Server

    Cattaneo, P W; Boffelli, F; Bulgarelli, A; Buonomo, B; Chen, A W; D’Ammando, F; FoggettA, L; Froysland, T; Fuschino, F; Galli, M; Gianotti, F; Giuliani, A; Longo, F; Marisaldi, M; Mazzitelli, G; Pellizzoni, A; Prest, M; Pucella, G; Quintieri, L; Rappoldi, A; Tavani, M; Trifoglio, M; Trois, A; Valente, P; Vallazza, E; Vercellone, S; Zambra, A; Barbiellini, G; Caraveo, P; Cocco, V; Costa, E; De Paris, G; Del Monte, E; Di Cocco, G; Donnarumma, I; Evangelista, Y; Feroci, M; Ferrari, A; Fiorini, M; Labanti, C; Lapshov, I; Lazzarotto, F; Lipari, P; Mastropietro, M; Mereghetti, S; Morelli, E; Moretti, E; Morselli, A; Pacciani, L; Perotti, F; Piano, G; Picozza, P; Pilia, M; Porrovecchio, G; Rapisarda, M; Rubini, A; Sabatini, S; Soffitta, P; Striani, E; Vittorini, V; Zanello, D; Colafrancesco, S; Giommi, P; Pittori, C; Santolamazza, P; Verrecchia, F; Salotti, L

    2012-01-01

    At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a γ-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the γ rays. A tagged γ-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating γ-rays through bremsstrahlung in a position-sensitive target. The γ-ray energy is deduced by difference with the post-bremsstrahlung electron energy [1] and [2]. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon be...

  11. HIGH POWER FAST KICKER SYSTEM FOR SNS BEAM EXTRACTION.

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG,W.; SANDBERG,J.; TSOUPAS,N.; MI,J.; LAMBIASE,R.; LOCKEY,R.; PAI,C.; TUOZZOLO,J.; NEHRING,T.; WARBURTON,D.

    2002-06-30

    A Blumlein topology based high peak power, high repetition rate, and low beam impedance fast extraction kicker system for ORNL Spallation Neutron Source (SNS) is being developed at Brookhaven National Laboratory. The large magnet window size, large deflecting angle, low beam impedance termination and fast deflecting field rise time demand a very strong pulsed power source to drive the SNS extraction fast kicker magnet. This system consists of fourteen high voltage modulators and fourteen lumped kicker magnet sections. All modulators will be located in a service building outside the beam tunnel, which is a revised design requirement adopted in the mid 2000. The high current pulses generated by the high power modulators will be delivered through high voltage pulsed transmission cables to each kicker magnet sections. The designed output capacity of this system, is in multiple GVA. Its first article modulator has been constructed and is being tested. In this paper, we present the system overview, project status and the advantages of this new conceptual design.

  12. Measurements of an ion beam diameter extracted into air through a glass capillary

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Natsuko, E-mail: fujita.natsuko@jaea.go.jp [Graduate School of Humanities and Sciences, Nara Women’s University, Nara, 630 8506 (Japan); Yamaki, Atsuko [Graduate School of Humanities and Sciences, Nara Women’s University, Nara, 630 8506 (Japan); Ishii, Kunikazu; Ogawa, Hidemi [Department of Physics, Nara Women’s University, Nara, 630 8506 (Japan)

    2013-11-15

    To establish techniques for in-air materials analysis using a glass capillary, we studied the beam distribution extracted in air as a function of the distance between the exit of the capillary and the target. We measured three-dimensional intensity distributions of the extracted beams, and compared the observed results with the model calculation. The comparison showed that the glass capillary technique is designed to reduce a divergence of the beam extracted into the air by a beam-focusing effect.

  13. Point Cloud Oriented Shoulder Line Extraction in Loess Hilly Area

    Science.gov (United States)

    Min, Li; Xin, Yang; Liyang, Xiong

    2016-06-01

    Shoulder line is the significant line in hilly area of Loess Plateau in China, dividing the surface into positive and negative terrain (P-N terrains). Due to the point cloud vegetation removal methods of P-N terrains are different, there is an imperative need for shoulder line extraction. In this paper, we proposed an automatic shoulder line extraction method based on point cloud. The workflow is as below: (i) ground points were selected by using a grid filter in order to remove most of noisy points. (ii) Based on DEM interpolated by those ground points, slope was mapped and classified into two classes (P-N terrains), using Natural Break Classified method. (iii) The common boundary between two slopes is extracted as shoulder line candidate. (iv) Adjust the filter gird size and repeat step i-iii until the shoulder line candidate matches its real location. (v) Generate shoulder line of the whole area. Test area locates in Madigou, Jingbian County of Shaanxi Province, China. A total of 600 million points are acquired in the test area of 0.23km2, using Riegl VZ400 3D Laser Scanner in August 2014. Due to the limit Granted computing performance, the test area is divided into 60 blocks and 13 of them around the shoulder line were selected for filter grid size optimizing. The experiment result shows that the optimal filter grid size varies in diverse sample area, and a power function relation exists between filter grid size and point density. The optimal grid size was determined by above relation and shoulder lines of 60 blocks were then extracted. Comparing with the manual interpretation results, the accuracy of the whole result reaches 85%. This method can be applied to shoulder line extraction in hilly area, which is crucial for point cloud denoising and high accuracy DEM generation.

  14. POINT CLOUD ORIENTED SHOULDER LINE EXTRACTION IN LOESS HILLY AREA

    Directory of Open Access Journals (Sweden)

    L. Min

    2016-06-01

    Full Text Available Shoulder line is the significant line in hilly area of Loess Plateau in China, dividing the surface into positive and negative terrain (P-N terrains. Due to the point cloud vegetation removal methods of P-N terrains are different, there is an imperative need for shoulder line extraction. In this paper, we proposed an automatic shoulder line extraction method based on point cloud. The workflow is as below: (i ground points were selected by using a grid filter in order to remove most of noisy points. (ii Based on DEM interpolated by those ground points, slope was mapped and classified into two classes (P-N terrains, using Natural Break Classified method. (iii The common boundary between two slopes is extracted as shoulder line candidate. (iv Adjust the filter gird size and repeat step i-iii until the shoulder line candidate matches its real location. (v Generate shoulder line of the whole area. Test area locates in Madigou, Jingbian County of Shaanxi Province, China. A total of 600 million points are acquired in the test area of 0.23km2, using Riegl VZ400 3D Laser Scanner in August 2014. Due to the limit Granted computing performance, the test area is divided into 60 blocks and 13 of them around the shoulder line were selected for filter grid size optimizing. The experiment result shows that the optimal filter grid size varies in diverse sample area, and a power function relation exists between filter grid size and point density. The optimal grid size was determined by above relation and shoulder lines of 60 blocks were then extracted. Comparing with the manual interpretation results, the accuracy of the whole result reaches 85%. This method can be applied to shoulder line extraction in hilly area, which is crucial for point cloud denoising and high accuracy DEM generation.

  15. Optical substrate materials for synchrotron radiation beam lines

    Science.gov (United States)

    Howells, Malcolm R.; Paquin, Roger A.

    1997-09-01

    We consider the materials choices available for making optical substrates for synchrotron radiation beam lines. We find that currently the optical surfaces can only be polished to the required finish in fused silica and other glasses, silicon, CVD silicon carbide, electroless nickel and 17-4 PH stainless steel. Substrates must therefore be made of one of these materials or of a metal that can be coated with electroless nickel. In the context of material choices for mirrors we explore the issues of dimensional stability, polishing, bending, cooling, and manufacturing strategy. We conclude that metals are best from an engineering and cost standpoint while the ceramics are best from a polishing standpoint. We then give discussions of specific materials as follows: silicon carbide, silicon, electroless nickel, GlidcopTM, aluminum, precipitation- hardening stainless steel, mild steel, invar and superinvar. Finally we summarize conclusions and propose ideas for further research.

  16. Orbit error correction on the high energy beam transport line at the KHIMA accelerator system

    Science.gov (United States)

    Park, Chawon; Yim, Heejoong; Hahn, Garam; An, Dong Hyun

    2016-09-01

    For the purpose of treatment of various cancers and medical research, a synchrotron based medical machine has been developed under the Korea Heavy Ion Medical Accelerator (KHIMA) project and is scheduled for use to treat patient at the beginning of 2018. The KHIMA synchrotron is designed to accelerate and extract carbon ion (proton) beams with various energies from 110 to 430 MeV/u (60 to 230 MeV). Studies on the lattice design and beam optics for the High Energy Beam Transport (HEBT) line at the KHIMA accelerator system have been carried out using the WinAgile and the MAD-X codes. Because magnetic field errors and misalignments introduce deviations from the design parameters, these error sources should be treated explicitly, and the sensitivity of the machine's lattice to different individual error sources should be considered. Various types of errors, both static and dynamic, have been taken into account and have been consequentially corrected with a dedicated correction algorithm by using the MAD-X program. Based on the error analysis, the optimized correction setup is decided, and the specifications for the correcting magnets of the HEBT lines are determined.

  17. 3D CENTRAL LINE EXTRACTION OF FOSSIL OYSTER SHELLS

    Directory of Open Access Journals (Sweden)

    A. Djuricic

    2016-06-01

    Full Text Available Photogrammetry provides a powerful tool to digitally document protected, inaccessible, and rare fossils. This saves manpower in relation to current documentation practice and makes the fragile specimens more available for paleontological analysis and public education. In this study, high resolution orthophoto (0.5 mm and digital surface models (1 mm are used to define fossil boundaries that are then used as an input to automatically extract fossil length information via central lines. In general, central lines are widely used in geosciences as they ease observation, monitoring and evaluation of object dimensions. Here, the 3D central lines are used in a novel paleontological context to study fossilized oyster shells with photogrammetric and LiDAR-obtained 3D point cloud data. 3D central lines of 1121 Crassostrea gryphoides oysters of various shapes and sizes were computed in the study. Central line calculation included: i Delaunay triangulation between the fossil shell boundary points and formation of the Voronoi diagram; ii extraction of Voronoi vertices and construction of a connected graph tree from them; iii reduction of the graph to the longest possible central line via Dijkstra’s algorithm; iv extension of longest central line to the shell boundary and smoothing by an adjustment of cubic spline curve; and v integration of the central line into the corresponding 3D point cloud. The resulting longest path estimate for the 3D central line is a size parameter that can be applied in oyster shell age determination both in paleontological and biological applications. Our investigation evaluates ability and performance of the central line method to measure shell sizes accurately by comparing automatically extracted central lines with manually collected reference data used in paleontological analysis. Our results show that the automatically obtained central line length overestimated the manually collected reference by 1.5% in the test set, which

  18. D Central Line Extraction of Fossil Oyster Shells

    Science.gov (United States)

    Djuricic, A.; Puttonen, E.; Harzhauser, M.; Mandic, O.; Székely, B.; Pfeifer, N.

    2016-06-01

    Photogrammetry provides a powerful tool to digitally document protected, inaccessible, and rare fossils. This saves manpower in relation to current documentation practice and makes the fragile specimens more available for paleontological analysis and public education. In this study, high resolution orthophoto (0.5 mm) and digital surface models (1 mm) are used to define fossil boundaries that are then used as an input to automatically extract fossil length information via central lines. In general, central lines are widely used in geosciences as they ease observation, monitoring and evaluation of object dimensions. Here, the 3D central lines are used in a novel paleontological context to study fossilized oyster shells with photogrammetric and LiDAR-obtained 3D point cloud data. 3D central lines of 1121 Crassostrea gryphoides oysters of various shapes and sizes were computed in the study. Central line calculation included: i) Delaunay triangulation between the fossil shell boundary points and formation of the Voronoi diagram; ii) extraction of Voronoi vertices and construction of a connected graph tree from them; iii) reduction of the graph to the longest possible central line via Dijkstra's algorithm; iv) extension of longest central line to the shell boundary and smoothing by an adjustment of cubic spline curve; and v) integration of the central line into the corresponding 3D point cloud. The resulting longest path estimate for the 3D central line is a size parameter that can be applied in oyster shell age determination both in paleontological and biological applications. Our investigation evaluates ability and performance of the central line method to measure shell sizes accurately by comparing automatically extracted central lines with manually collected reference data used in paleontological analysis. Our results show that the automatically obtained central line length overestimated the manually collected reference by 1.5% in the test set, which is deemed

  19. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    Energy Technology Data Exchange (ETDEWEB)

    Huikari, J. E-mail: jussi.huikari@phys.jyu.fi; Dendooven, P.; Jokinen, A.; Nieminen, A.; Penttilae, H.; Peraejaervi, K.; Popov, A.; Rinta-Antila, S.; Aeystoe, J

    2004-08-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on {alpha}-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporation reactions are introduced. The present study investigated different schemes for ion extraction from the gas cell. The addition of an extra ring electrode between the traditional skimmer electrode and the exit hole led to transmission independent of the primary beam intensity as opposed to strong intensity dependence observed earlier with the plain skimmer only. Furthermore, the mass resolving power of the IGISOL mass separator was increased to 1100 as compared to 250 with the skimmer system when using the RF-sextupole for the extraction from the heavy-ion ion guide. As a new method, the possibility to increase the ion guide efficiency by injecting electrons into the stopping volume is introduced. The efficiency of the electron emitter ion guide was a factor of ten higher in off-line conditions. Also, the influence of the buffer gas purity on the ion survival is discussed.

  20. Monitoring extracted beams of the nuclotron accelerator complex for "energy + transmutation" experiments

    Science.gov (United States)

    Baldin, A. A.; Berlev, A. I.; Vasil'ev, S. E.; Vishnevskiy, A. V.; Vladimirova, N. M.; Kudashkin, I. V.; Makan'kin, A. M.; Paraipan, M.; Tyutyunnikov, S. I.

    2016-03-01

    A monitoring system for measuring absolute intensity and the space—time structure of extracted beams of Nuclotron based on ionization and activation methods has been created and tested. The monitoring system provides a measurement of the absolute intensity of extracted beams with a precision of 10% and beam position with a precision of 0.5 mm.

  1. REDUCING BEAM COUPLING IMPEDANCES IN SNS RING EXTRACTION KICKERS

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey); Davino, D. (Daniele); Lee, Y. Y.

    2001-01-01

    The Spallation Neutron Source (SNS) Accumulator ring extraction system includes 14 modules of windowframe ferrite pulsing kicker magnets with the rise time of about 200 ns. Their contribution to the beam coupling impedances is a serious concern. The kicker impedances, as well as its deflecting magnetic field versus time, are studied using detailed 3-D MAFIA modeling. Various design options, external circuit resistances, and a range of ferrite permeabilities are explored. A kicker module with wide conductor windings around the ferrite behind the kicker current sheet suggests a significant reduction of the kicker transverse and longitudinal coupling impedances. This design provides a good extraction field performance, as demonstrated by electromagnetic simulations. Results of measurements for a small model are also presented.

  2. REDUCING BEAM COUPLING IMPEDANCES IN SNS RING EXTRACTION KICKERS.

    Energy Technology Data Exchange (ETDEWEB)

    KURENNOY,S.S.; DAVINO,D.; LEE,Y.Y.

    2001-06-18

    The Spallation Neutron Source (SNS) Accumulator ring extraction kickers [1] consists of 14 modules of windowframe ferrite pulsing magnets with the rise time of about 200 ns. Their contribution to the beam coupling impedances is a serious concern. The kicker impedances, as well as its deflecting magnetic field versus time, are studied using detailed 3-D MAFIA modeling. Various design options, external circuit resistances, and a range of ferrite permeabilities are explored. A kicker module with wide conductor windings around the ferrite behind the kicker current sheet suggests a significant reduction of the kicker transverse and longitudinal coupling impedances. This design provides a good extraction field performance, as demonstrated by electromagnetic simulations. Results of measurements for a small model are also presented.

  3. REDUCING BEAM COUPLING IMPEDANCES IN SNS RING EXTRACTION KICKERS

    Energy Technology Data Exchange (ETDEWEB)

    S.S. KURENNOY; D. DAVINO; Y. LEE

    2001-06-01

    The Spallation Neutron Source (SNS) Accumulator ring extraction system [1] includes 14 modules of window-frame ferrite pulsing kicker magnets with the rise time of about 200 ns. Their contribution to the beam coupling impedances is a serious concern. The kicker impedances, as well as its deflecting magnetic field versus time, are studied using detailed 3-D MAFIA modeling. Various design options, external circuit resistances, and a range of ferrite permeabilities are explored. A kicker module with wide conductor windings around the ferrite behind the kicker current sheet suggests a significant reduction of the kicker transverse and longitudinal coupling impedances. This design provides a good extraction field performance, as demonstrated by electromagnetic simulations. Results of measurements for a small model are also presented.

  4. Extracting respiratory signals from thoracic cone beam CT projections

    CERN Document Server

    Yan, Hao; Yin, Wotao; Pan, Tinsu; Ahmad, Moiz; Mou, Xuanqin; Cervino, Laura; Jia, Xun; Jiang, Steve B

    2012-01-01

    Patient respiratory signal associated with the cone beam CT (CBCT) projections is important for lung cancer radiotherapy. In contrast to monitoring an external surrogate of respiration, such signal can be extracted directly from the CBCT projections. In this paper, we propose a novel local principle component analysis (LPCA) method to extract the respiratory signal by distinguishing the respiration motion-induced content change from the gantry rotation-induced content change in the CBCT projections. The LPCA method is evaluated by comparing with three state-of-the-art projection-based methods, namely, the Amsterdam Shroud (AS) method, the intensity analysis (IA) method, and the Fourier-transform based phase analysis (FT-p) method. The clinical CBCT projection data of eight patients, acquired under various clinical scenarios, were used to investigate the performance of each method. We found that the proposed LPCA method has demonstrated the best overall performance for cases tested and thus is a promising tech...

  5. Beam dynamics and error study of the medium energy beam transport line in the Korea Heavy-Ion Medical Accelerator

    Science.gov (United States)

    Kim, Chanmi; Kim, Eun-San; Hahn, Garam

    2016-11-01

    The Korea Heavy Ion Medical Accelerator consists of an injector and a synchrotron for an ion medical accelerator that is the first carbon-ion therapy system in Korea. The medium energy beam transport(MEBT) line connects the interdigital H-mode drift tube linac and the synchrotron. We investigated the beam conditions after the charge stripper by using the LISE++ and the SRIM codes. The beam was stripped from C4+ into C6+ by using the charge stripper. We investigated the performance of a de-buncher in optimizing the energy spread and the beam distribution in z-dW/W (direction of beam progress-beam and energy) phase. We obtained the results of the tracking simulation and the error analysis by using the TRACK code. Possible misalignments and rotations of the magnets were considered in the simulations. States of the beam were examined when errors occurred in the magnets by the applying analytic fringe field model in TRACK code. The condition for the beam orbit was optimized by using correctors and profile monitors to correct the orbit. In this paper, we focus on the beam dynamics and the error studies dedicated to the MEBT beam line and show the optimized beam parameters for the MEBT.

  6. New magnet transport system for the LHC beam transfer lines

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system (pictured here in one of the tunnels) is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The lead vehicle is powered by an electric rail set into the roof of the tunnel. The system is backed up by electrical batteries that enable it to operate in the absence of an outside power source or in the event of power failure. Last but not least, for the long-distance transport of magnets, it can be optically guided by a line traced on the tunnel floor. The convoy moves through the particularly narr...

  7. Lattice design and beam dynamics studies of the high energy beam transport line in the RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hyunchang, E-mail: hcjin@ibs.re.kr; Jang, Ji-Ho; Jang, Hyojae; Jeon, Dong-O

    2015-12-01

    In RAON heavy ion accelerator, beams generated by superconducting electron cyclotron resonance ion source (ECR-IS) or Isotope Separation On-Line (ISOL) system are accelerated by lower energy superconducting linac and high energy superconducting linac. The accelerated beams are used in the high energy experimental hall which includes bio-medical and muon-SR facilities, after passing through the high energy beam transport lines. At the targets of those two facilities, the stable and small beams meeting the requirements rigorously are required in the transverse plane. Therefore the beams must be safely sent to the targets and simultaneously satisfy the two requirements, the achromatic condition and the mid-plane symmetric condition, of the targets. For this reason, the lattice design of the high energy beam transport lines in which the long deflecting sections are included is considered as a significant issue in the RAON accelerator. In this paper, we will describe the calculated beam optics satisfying the conditions and present the result of particle tracking simulations with the designed lattice of the high energy beam transport lines in the RAON accelerator. Also, the orbit distortion caused by the machine imperfections and the orbit correction with correctors will be discussed.

  8. Micron size laser-wire system at the ATF extraction line, recent results and ATF-II upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Aryshev, A., E-mail: alar@post.kek.j [John Adams Institute at Royal Holloway, Egham, Surrey TW20 0EX (United Kingdom); Blair, G.A.; Boogert, S.T.; Boorman, G.; Bosco, A. [John Adams Institute at Royal Holloway, Egham, Surrey TW20 0EX (United Kingdom); Corner, L. [John Adams Institute at Oxford University, Nuclear and Astrophysics Laboratory, Keble Road, Oxford OX1 3RH (United Kingdom); Deacon, L. [John Adams Institute at Royal Holloway, Egham, Surrey TW20 0EX (United Kingdom); Delerue, N.; Foster, B.; Gannaway, F. [John Adams Institute at Oxford University, Nuclear and Astrophysics Laboratory, Keble Road, Oxford OX1 3RH (United Kingdom); Hayano, H. [KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Howell, D. [John Adams Institute at Oxford University, Nuclear and Astrophysics Laboratory, Keble Road, Oxford OX1 3RH (United Kingdom); Karataev, P. [John Adams Institute at Royal Holloway, Egham, Surrey TW20 0EX (United Kingdom); Nevay, L.; Newman, M.; Senanayake, R. [John Adams Institute at Oxford University, Nuclear and Astrophysics Laboratory, Keble Road, Oxford OX1 3RH (United Kingdom); Terunuma, N.; Urakawa, J. [KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Walczak, R. [John Adams Institute at Oxford University, Nuclear and Astrophysics Laboratory, Keble Road, Oxford OX1 3RH (United Kingdom)

    2010-11-01

    The KEK Accelerator test facility (ATF) extraction line laser-wire system has been upgraded last year allowing the measurement of micron scale transverse size electron beams. The last measurements using the upgraded system from recent operation at the ATF are presented, demonstrating raw measurements of order 3{mu}m RMS. The main component contributions to this measurement are also discussed.

  9. Micron size laser-wire system at the ATF extraction line, recent results and ATF-II upgrade

    Science.gov (United States)

    Aryshev, A.; Blair, G. A.; Boogert, S. T.; Boorman, G.; Bosco, A.; Corner, L.; Deacon, L.; Delerue, N.; Foster, B.; Gannaway, F.; Hayano, H.; Howell, D.; Karataev, P.; Nevay, L.; Newman, M.; Senanayake, R.; Terunuma, N.; Urakawa, J.; Walczak, R.

    2010-11-01

    The KEK Accelerator test facility (ATF) extraction line laser-wire system has been upgraded last year allowing the measurement of micron scale transverse size electron beams. The last measurements using the upgraded system from recent operation at the ATF are presented, demonstrating raw measurements of order 3 μm RMS. The main component contributions to this measurement are also discussed.

  10. Commissioning of the Beam Interlock System for the TT40 and TT41 Transfer Lines of the SPS

    CERN Document Server

    Wenninger, J; Kain, V; CERN. Geneva. AB Department

    2007-01-01

    The extraction area of LSS4 in the SPS and the TT40 and TT41 transfer lines have been equipped with a new interlock system to protect the machine elements against beam induced failure during operation with the high intensity CNGS beams. The system commissioning that was performed during the 2006 SPS run followed pre-defined commissioning procedures. An extensive WEB based documentation of the tests has been established to track the state of the interlock system, in particular of interlock references. This document presents a short summary of the commissioning as well as the complete documentation of the interlock tests.

  11. Analytical and simulation studies for diode and triode ion beam extraction systems

    Institute of Scientific and Technical Information of China (English)

    M. M. Abdelrahman1; N. I. Basal; S. G. Zakhary

    2012-01-01

    This work is concerned with ion beam dynamics and compares the emittance to aberration ratios of two-and three-electrode extraction systems.The study is conducted with the aid of Version 7 of SIMION 3D ray-tracing software.The beam dependence on various parameters of the extraction systems is studied and the numerical results lead to qualitative conclusions.Ion beam characteristics using diode and triode extraction systems are investigated with the aid of the computer code SIMION 3 D,Version 7.0. The diode (two electrode extraction system) and triode (threeelectrode extraction,acceleration-deceleration system) extraction systems are designed and optimized with different geometric parameters of the electrode system,voltage applied to the extraction electrode,and plasma parameters inside the ion source chamber,as well as by the ion beam space charge.This work attempts to describe the importance of the acceleration-deceleration extraction system.It shows that besides an increase of the beam energy,the ion beam has lower emittance than the two-electrode extraction system.Ion beams of the highest quality are extracted whenever the half-angular divergence is minimum for which the perveance current intensity and the extraction gap have optimum value.Knowing the electron temperature of the plasma is necessary to determine plasma potential and the exact beam energy.

  12. Extraction of high-intensity ion beams from a laser plasma by a pulsed spherical diode

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Oguri

    2005-06-01

    Full Text Available High-current Cu^{+} ion beams were extracted from a laser-produced plasma using a pulsed high-voltage multiaperture diode driven by an induction cavity. The amplitude and the duration of the extraction voltage were 130 kV and 450 ns, respectively. During the extraction, explosive beam divergence due to the strong space-charge force was suppressed by the focusing action of the gap between concentric hemispheres. Modulation of the extracted beam flux due to the plasma prefill in the gap has been eliminated by using a biased control grid put on the anode holes. By means of this extraction scheme we obtained a rectangular beam pulse with a rise time as short as ≈100  ns. The beam current behind the cathode was limited to ≈0.1   A, owing to space-charge effects, as well as to poor geometrical transmission through the cathode sphere. From the measurement of the extracted beam current density distribution along the beam axis and the beam profile measurement, we found a beam waist slightly downstream of the spherical center of the diode structure. The measured beam behavior was consistent with numerical results obtained via a 3D particle code. No serious degradation of the beam emittance was observed for the grid-controlled extraction scheme.

  13. Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation

    Institute of Scientific and Technical Information of China (English)

    杨尧; 赵红卫; 原有进; 冯玉成; 孙良亭; 方兴; 卢旺; 张文慧; 曹云; 张雪珍

    2015-01-01

    The operation of the HIRFL accelerator has shown that the beam transmission efficiency of the sector focusing cyclotron (SFC) injector line is rather poor. Beam simulations have been performed to investigate the possible causes for this low transmission. It is predicted that the property of transversal coupling of the ion beam from electron cyclotron resonance (ECR) ion source can be an important factor to degrade the beam quality by increasing the beam emittance, resulting in a serious particle loss. An improved operation scheme for the SECRAL associated line has been proposed, and the corresponding experiment was carried out. This paper presents the test results.

  14. RI-induced reaction studies by new energy-degrading beam line, OEDO

    Science.gov (United States)

    Michimasa, Shin'ichiro

    2014-09-01

    The RI beam factory (RIBF) has expanded variety of accessible nuclei, and provides very intense RI beams. However, the beams are energy range of above 100 MeV/u, and are not necessarily suitable to some kinds of nuclear reactions. Therefore, deceleration of intense RI beams from RIBF open potentially new scientific opportunities to access various states in exotic nuclei by using characteristics probes, such as transfer reactions at several ten MeV/u and fusion reactions at several MeV/u. For energy degrading of nuclear beams, the degrader is generally used. This method easily controls beam energy, while multiple scattering effect and energy straggling in the material broaden the beam spot size at the downstream foci. Therefore, a key issue for reaction measurements is achievement of ion transport to reduce the beam emittance at the secondary target. For this purpose, CNS has set up OEDO (Optimized Energy Degrading Optics for RI beam) project for production of high-quality low energy RI beams. The OEDO beam line scheme is planned to be achieved by re-arrangement of magnets of the high-resolution beam line, where the SHARAQ spectrometer is useful as a spectrograph for low-energy reaction spectroscopy. In this presentation, I will discuss scientific opportunities in the OEDO beam line and the SHARAQ spectrometer.

  15. Decorative Line and Edge Extraction in Cartoon Images

    Directory of Open Access Journals (Sweden)

    Tiejun Zhang

    2013-04-01

    Full Text Available Decorative Lines and edges in a cartoon image are the most important elements to convey its semantic information. In this study, we propose a method to extract both decorative lines and edges of the cartoon image at the same time. Firstly, we use the Hessian matrix to compute the direction perpendicular to the decorative lines in the image. Then, non-maximum suppression is applied to the image’s second derivative of Gaussian to locate the possible decorative line’s center. Secondly, we use directional zero-crossing (the zero-crossing of the first Gaussian derivative on the precomputed direction to verify the existence of the decorative lines. Finally, decorative lines and the edges detected by non-maximum suppression on the first Gaussian derivative are fused together. The experimental results show that our method is more effective than other existed methods in literature for complicated cartoon images.

  16. Design of the plasma chamber and beam extraction system for SC ECRIS of RAON accelerator

    Science.gov (United States)

    Kim, Y.; Choi, S.; Hong, I. S.

    2014-02-01

    The RAON accelerator is the heavy ion accelerator being built in Korea. It contains a 3rd generation SC ECRIS which uses 28 GHz/18 GHz microwave power to extract 12 puA uranium ion beams. A plasma chamber for that ECRIS is made of aluminum machined from bulk Al. That chamber contains cooling channels to remove dumped power and another access port for microwave introduction and plasma diagnostics. Beam extraction electrodes were designed considering the engineering issues and preliminary beam extraction analysis was done. That plasma chamber will be assembled with a cryostat, and beam extraction experiment will be done.

  17. Development of beam current control system in RF-knockout slow extraction

    Science.gov (United States)

    Mizushima, K.; Sato, S.; Shirai, T.; Furukawa, T.; Katagiri, K.; Takeshita, E.; Iwata, Y.; Himukai, T.; Noda, K.

    2011-12-01

    A raster scanning method has been developed for cancer therapy at NIRS-HIMAC. This method requires a high-accuracy beam current control and fast beam-on/off switching. We have developed a feedback control system of the beam current with the RF-knockout slow extraction method. The system has allowed a stable response to beam-on/off switching using a feedback control delay function with a beam-current ripple of 7%.

  18. Development of beam current control system in RF-knockout slow extraction

    Energy Technology Data Exchange (ETDEWEB)

    Mizushima, K., E-mail: mizshima@nirs.go.jp [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Graduate School of Science and Technology, Chiba University, Yayoi-cho, Inage-ku, Chiba 263-8522 (Japan); Sato, S.; Shirai, T.; Furukawa, T.; Katagiri, K.; Takeshita, E.; Iwata, Y.; Himukai, T.; Noda, K. [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2011-12-15

    A raster scanning method has been developed for cancer therapy at NIRS-HIMAC. This method requires a high-accuracy beam current control and fast beam-on/off switching. We have developed a feedback control system of the beam current with the RF-knockout slow extraction method. The system has allowed a stable response to beam-on/off switching using a feedback control delay function with a beam-current ripple of 7%.

  19. Orbit Error Correction on the High Energy Beam Transport Line at the KHIMA Accelerator System

    CERN Document Server

    Park, Chawon; Hahn, Garam; An, Dong Hyun

    2016-01-01

    For the purpose of treatment of various cancer and medical research, the synchrotron based medical machine under the Korea Heavy Ion Medical Accelerator (KHIMA) project have been conducted and is going to treat the patient at the beginning of 2018. The KHIMA synchrotron is designed to accelerate and extract the carbon ion (proton) beam with various energy range, 110 up to 430 MeV/u (60 up to 230 MeV). A lattice design and beam optics studies for the High Energy Beam Transport (HEBT) line at the KHIMA accelerator system have been carried out with WinAgile and the MAD-X codes. Because the magnetic eld errors and the mis-alignments introduce to the deviations from the design parameters, these error sources should be treated explicitly and the sensitivity of the machine's lattice to di erent individual error sources is considered. Various types of errors which are static and dynamic one have been taken into account and have been consequentially corrected with a dedicated correction algorithm by using the MAD-X pr...

  20. REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.

    Energy Technology Data Exchange (ETDEWEB)

    FOERSTER,C.

    1999-05-01

    Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are used at various beam line locations so that the monochromator, mirror box or sample chamber may be used in a helium atmosphere or rough vacuum. The window separates ring vacuum from the environment of the downstream beam line components. The stored beam lifetime in the storage rings and the maintenance of desirable reflection properties of optical surfaces depend upon hydrocarbon-free, ultra-high vacuum systems. Storage ring vacuum systems will operate at pressures of {approximately} 1 x 10{sup {minus}10} Torr without beam and {approximately} 1 x 10{sup {minus}9} Torr with beam. Systems are free of hydrocarbons in the sense that no pumps, valves, etc. containing organics are used. Components are all-metal, chemically cleaned and bakeable. To the extent that beam lines share a common vacuum with the storage ring, the same criteria will hold for beam line components. The design philosophy for NSLS beam lines is to use all-metal, hydrocarbon-free front end components and recommend that experimenters use this approach for common vacuum hardware

  1. Beam chopper For the Low-Energy Undulator Test Line (LEUTL) in the APS

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Y.; Wang, J.; Milton, S.; Teng, L. [and others

    1997-08-01

    The low-energy undulator test line (LEUTL) is being built and will be tested with a short beam pulse from an rf gun in the Advanced Photon Source (APS) at the Argonne National Laboratory. In the LEUTL a beam chopper is used after the rf gun to deflect the unwanted beam to a beam dump. The beam chopper consists of a permanent magnet and an electric deflector that can compensate for the magnetic deflection. A 30-kV pulsed power supply is used for the electric deflector. The chopper subsystem was assembled and tested for beamline installation. The electrical and beam properties of the chopper assembly are presented.

  2. An after-market, five-port vertical beam line extension for the PETtrace

    DEFF Research Database (Denmark)

    Barnhart, T. E.; Engle, J. W.; Severin, Gregory

    2012-01-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target...... positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates. © 2012 American Institute of Physics...

  3. An after-market, five-port vertical beam line extension for the PETtrace

    Science.gov (United States)

    Barnhart, T. E.; Engle, J. W.; Severin, G. W.; Valdovinos, H. F.; Gagnon, K.; Nickles, R. J.

    2012-12-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates.

  4. Extraction of power lines from mobile laser scanning data

    Science.gov (United States)

    Xiang, Qing; Li, Jonathan; Wen, Chenglu; Huang, Pengdi

    2016-03-01

    Modern urban life is becoming increasingly more dependent on reliable electric power supply. Since power outages cause substantial financial losses to producers, distributors and consumers of electric power, it is in the common interest to minimize failures of power lines. In order to detect defects as early as possible and to plan efficiently the maintenance activities, distribution networks are regularly inspected. Carrying out foot patrols or climbing the structures to visually inspect transmission lines and aerial surveys (e.g., digital imaging or most recent airborne laser scanning (ALS) are the two most commonly used methods of power line inspection. Although much faster in comparison to the foot patrol inspection, aerial inspection is more expensive and usually less accurate, in complex urban areas particularly. This paper presents a scientific work that is done in the use of mobile laser scanning (MLS) point clouds for automated extraction of power lines. In the proposed method, 2D power lines are extracted using Hough transform in the projected XOY plane and the 3D power line points are visualized after the point searching. Filtering based on an elevation threshold is applied, which is combined with the vehicle's trajectory in the horizontal section.

  5. A Study on the Ion Beam Extraction using Duo-PiGatron Ion source for Vertical Type Ion Beam Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sok; Lee, Chan young; Lee, Jae Sang [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In Korea Multipurpose Accelerator Complex (KOMAC), we have started ion beam service in the new beam utilization building since March this year. For various ion beam irradiation services, we are developed implanters such as metal (150keV/1mA), gaseous (200keV/5mA) and high current ion beam facility (20keV/150mA). One of the new one is a vertical type ion beam facility without acceleration tube (60keV/20mA) which is easy to install the sample. After the installation is complete, it is where you are studying the optimal ion beam extraction process. Detailed experimental results will be presented. Vertical Type Ion Beam Facility without acceleration tube of 60keV 20mA class was installed. We successfully extracted 60keV 20mA using Duo- PiGatron Ion source for Vertical Type Ion Beam Facility. Use the BPM and Faraday-cup, is being studied the optimum conditions of ion beam extraction.

  6. A beam position monitor for the diagnostic line in MEBT2 of J-PARC linac

    Science.gov (United States)

    Miura, A.; Tamura, J.; Kawane, Y.

    2017-07-01

    In the linac of the Japan Proton Accelerator Research Complex (J-PARC), the neutral hydrogen (H0) beam from the negative hydrogen ion (H-) beam is one of key issues in mitigating beam losses. To diagnose H0 particles, we installed a set of beam-bump magnets to generate a chicane orbit of the H- beam. The beam position monitors (BPMs) in the beam line are used for orbit correction to maintain the beam displacement within 2.0 mm from the duct center. To measure the beam displacement under different drive currents of the beam-bump magnets, a new wide-range BPM was designed and manufactured to evaluate the horizontal beam position by using a correction function to compensate for non-linearity. We also employed the beam profile monitor (WSM: wire scanner monitor) to measure the H- beam profile, which helped us to compare the beam position measurements. In this paper, the design and the performance of the wide-range BPM are described. In addition, we present a comparison of the beam position measured by the BPM and the WSM.

  7. Feedback phase correction of Bessel beams in confocal line light-sheet microscopy: a simulation study.

    Science.gov (United States)

    Moosavi, S Hoda; Gohn-Kreuz, Cristian; Rohrbach, Alexander

    2013-08-10

    Confocal line detection has been shown to improve contrast in light-sheet-based microscopy especially when illuminating the sample by Bessel beams. Besides their self-reconstructing capability, the stability in propagation direction of Bessel beams allows to block the unwanted emission light from the Bessel beam's ring system. However, due to phase aberrations induced especially at the border of the specimen, Bessel beams may not propagate along lines parallel to the slit detector. Here we present a concept of how to correct the phase of each incident Bessel beam such that the efficiency of confocal line detection is improved by up to 200%-300%. The applicability of the method is verified by the results obtained from numerical simulations based on the beam propagation method.

  8. An improved elliptic guide concept for a homogeneous neutron beam without direct line of sight

    CERN Document Server

    Zendler, C; Lieutenant, K

    2014-01-01

    Ballistic neutron guides are efficient for neutron transport over long distances, and in particular elliptically shaped guides have received much attention lately. However, elliptic neutron guides generally deliver an inhomogeneous divergence distribution when used with a small source, and do not allow kinks or curvature to avoid a direct view from source to sample. In this article, a kinked double-elliptic solution is found for neutron transport to a small sample from a small (virtual) source, as given e.g. for instruments using a pinhole beam extraction with a focusing feeder. A guide consisting of two elliptical parts connected by a linear kinked section is shown by VITESS simulations to deliver a high brilliance transfer as well as a homogeneous divergence distribution while avoiding direct line of sight to the source. It performs better than a recently proposed ellipse-parabola hybrid when used in a ballistic context with a kinked or curved central part. Another recently proposed solution, an analyticall...

  9. Detector Response and Beam Line Transmission Measurements with Far-Infrared Radiation

    CERN Document Server

    Grimm, O; Fröhlich, L

    2005-01-01

    Various activities at the TTF linear accelerator at DESY, Hamburg, that drives the VUV-FEL are geared towards measuring the longitudinal charge distribution of electron bunches with coherent far-infrared radiation. Examples are beam lines transporting synchrotron or transition radiation to interferometers mounted inside or outside the tunnel, and studies of single-shot grating spectrometers. All such approaches require a good understanding of the radiation generation and transport mechanism and of the detector characteristics to extract useful information on the charge distribution. Simulations and measurements of the expected transverse intensity distribution and polarization of synchrotron radiation emitted at the first bunch compressor of TTF have been performed. The transverse intensity scanning provided for the first time at DESY a visual image of the footprint of terahertz radiation. Detector response measurements have been performed at the FELIX facility, Netherlands, for wavelengths between 100-160 mi...

  10. Tomography and imaging at the PSICHE beam line of the SOLEIL synchrotron

    Science.gov (United States)

    King, A.; Guignot, N.; Zerbino, P.; Boulard, E.; Desjardins, K.; Bordessoule, M.; Leclerq, N.; Le, S.; Renaud, G.; Cerato, M.; Bornert, M.; Lenoir, N.; Delzon, S.; Perrillat, J.-P.; Legodec, Y.; Itié, J.-P.

    2016-09-01

    PSICHE (Pressure, Structure and Imaging by Contrast at High Energy) is the high-energy beam line of the SOLEIL synchrotron. The beam line is designed to study samples at extreme pressures, using diffraction, and to perform imaging and tomography for materials science and other diverse applications. This paper presents the tomograph and the use of the beam line for imaging, with emphasis on developments made with respect to existing instruments. Of particular note are the high load capacity rotation stage with free central aperture for installing large or complex samples and sample environments, x-ray mirror and filter optics for pink beam imaging, and multiple options for combining imaging and diffraction measurement. We describe how x-ray imaging techniques have been integrated into high-pressure experiments. The design and the specifications of the beam line are described, and several case studies drawn from the first user experiments are presented.

  11. The First On-line Radioactive Ion Beam from BRIF

    Institute of Scientific and Technical Information of China (English)

    CUI; Bao-qun; MA; Ying-jun; MA; Rui-gang; TANG; Bing; HUANG; Qing-hua; CHEN; Li-hua; MA; Xie

    2015-01-01

    Many of the reactions fundamentally important in nuclear physics and astrophysics can only be studied with high energy radioactive ion beams (RIBs).Radioactive ion beams offer unique opportunities to further our knowledge about the structure of the nucleus,the stellar processes.

  12. Upgraded millimeter-wave interferometer for measuring the electron density during the beam extraction in the negative ion source

    Science.gov (United States)

    Tokuzawa, T.; Kisaki, M.; Nagaoka, K.; Tsumori, K.; Ito, Y.; Ikeda, K.; Nakano, H.; Osakabe, M.; Takeiri, Y.; Kaneko, O.

    2016-11-01

    The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 1015 to 3 × 1018 m-3 in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

  13. Influence of time characteristics of beam extraction on coherent Bremsstrahlung spectra

    Energy Technology Data Exchange (ETDEWEB)

    Avakyan, R.O.; Avetisyan, A.E.; Sarkisyan, R.T.; Simonyan, K.A.; Taroyan, S.P.; Zapol' skii, N.A.

    1985-09-01

    This paper describes a new method of increasing the degree of polarization chromaticity of the coherent Bremsstrahlung spectra. The authors consider the time characteristics of electron-beam extraction from the Erevan synchrotron. By adjusting the extraction regime, the Bresstrahlung beam parameters can be controlled. Practical applications of the new method are discussed.

  14. Low intensity beam extracted from the CPS via CT or MTE with various longitudinal parameters

    CERN Document Server

    Bohl, T

    2009-01-01

    In view of extracting fixed target type of beams from the CPS for SPS fixed target physics or CNGS operation with the Multi-Turn-Extraction (MTE) scheme, beams with certain sets of longitudinal parameters were produced in the CPS and their transmission in the SPS was studied.

  15. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    CERN Document Server

    Bogomilov, M.; Kolev, D.; Russinov, I.; Tsenov, R.; Vankova-Kirilova, G.; Wang, L.; Xu, F.Y.; Zheng, S.X.; Bertoni, R.; Bonesini, M.; Ferri, F.; Lucchini, G.; Mazza, R.; Paleari, F.; Strati, F.; Palladino, V.; Cecchet, G.; de Bari, A.; Capponi, M.; Cirillo, A.; Iaciofano, A.; Manfredini, A.; Parisi, M.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Mori, Y.; Kuno, Y.; Sakamoto, H.; Sato, A.; Yano, T.; Yoshida, M.; Ishimoto, S.; Suzuki, S.; Yoshimura, K.; Filthaut, F.; Garoby, R.; Gilardoni, S.; Gruber, P.; Hanke, K.; Haseroth, H.; Janot, P.; Lombardi, A.; Ramberger, S.; Vretenar, M.; Bene, P.; Blondel, A.; Cadoux, F.; Graulich, J.S.; Grichine, V.; Gschwendtner, E.; Masciocchi, F.; Sandstrom, R.; Verguilov, V.; Wisting, H.; Petitjean, C.; Seviour, R.; Alexander, J.; Charnley, G.; Collomb, N.; Griffiths, S.; Martlew, B.; Moss, A.; Mullacrane, I.; Oates, A.; Owens, P.; White, C.; York, S.; Adams, D.; Apsimon, R.; Barclay, P.; Baynham, D.E.; Bradshaw, T.W.; Courthold, M.; Drumm, P.; Edgecock, R.; Hayler, T.; Hills, M.; Ivaniouchenkov, Y.; Jones, A.; Lintern, A.; MacWaters, C.; Nelson, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rochford, J.H.; Rogers, C.; Spensley, W.; Tarrant, J.; Tilley, K.; Watson, S.; Wilson, A.; Forrest, D.; Soler, F.J.P.; Walaron, K.; Cooke, P.; Gamet, R.; Alekou, A.; Apollonio, M.; Barber, G.; Clark, D.; Clark, I.; Dobbs, A.; Dornan, P.; Fish, A.; Hare, R.; Greenwood, S.; Jamdagni, A.; Kasey, V.; Khaleeq, M.; Leaver, J.; Long, K.; McKigney, E.; Matsushita, T.; Pasternak, J.; Sashalmi, T.; Savidge, T.; Takahashi, M.; Blackmore, V.; Carlisle, T.; Cobb, J.H.; Lau, W.; Rayner, M.; Tunnell, C.D.; Witte, H.; Yang, S.; Booth, C.N.; Hodgson, P.; Howlett, L.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.; Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Ellis, M.; Kyberd, P.; Littlefield, M.; Nebrensky, J.J.; Bross, A.D.; Geer, S.; Neuffer, D.; Moretti, A.; Popovic, M.; Cummings, M.A.C.; Roberts, T.J.; DeMello, A.; Green, M.A.; Li, D.; Virostek, S.; Zisman, M.S.; Freemire, B.; Hanlet, P.; Huang, D.; Kafka, G.; Kaplan, D.M.; Snopok, P.; Torun, Y.; Blot, S.; Kim, Y.K.; Bravar, U.; Onel, Y.; Cline, D.; Fukui, Y.; Lee, K.; Yang, X.; Rimmer, R.A.; Cremaldi, L.M.; Gregoire, G.; Hart, T.L.; Sanders, D.A.; Summers, D.J.; Coney, L.; Fletcher, R.; Hanson, G.G.; Heidt, C.; Gallardo, J.; Kahn, S.; Kirk, H.; Palmer, R.B.

    2012-01-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz muon rate, with a neglible pion contamination in the beam.

  16. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    CERN Document Server

    Bogomilov, M.

    2012-01-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz muon rate, with a neglible pion contamination in the beam.

  17. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bogomilov, M.; Karadzhov, Y.; Kolev, D.; Russinov, I.; Tsenov, R.; Vankova-Kirilova, G.; Wang, L.; Xu, F. Y.; Zheng, S. X.; Bertoni, R.; Bonesini, M.; Ferri, F.; Lucchini, G.; Mazza, R.; Paleari, F.; Strati, F.; Palladino, V.; Cecchet, G.; Bari, A. de; Capponi, M.; Cirillo, A.; Iaciofano, A.; Manfredini, A.; Parisi, M.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Mori, Y.; Kuno, Y.; Sakamoto, H.; Sato, A.; Yano, T.; Yoshida, M.; Ishimoto, S.; Suzuki, S.; Yoshimura, K.; Filthaut, F.; Garoby, R.; Gilardoni, S.; Gruber, P.; Hanke, K.; Haseroth, H.; Janot, P.; Lombardi, A.; Ramberger, S.; Vretenar, M.; Bene, P.; Blondel, A.; Cadoux, F.; Graulich, J. -S; Grichine, V.; Gschwendtner, E.; Masciocchi, F.; Sandstrom, R.; Verguilov, V.; Wisting, H.; Petitjean, C.; Seviour, R.; Alexander, J.; Charnley, G.; Collomb, N.; Griffiths, S.; Martlew, B.; Moss, A.; Mullacrane, I.; Oates, A.; Owens, P.; White, C.; York, S.; Adams, D.; Apsimon, R.; Barclay, P.; Baynham, D. E.; Bradshaw, T. W.; Courthold, M.; Drumm, P.; Edgecock, R.; Hayler, T.; Hills, M.; Ivaniouchenkov, Y.; Jones, A.; Lintern, A.; MacWaters, C.; Nelson, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rochford, J. H.; Rogers, C.; Spensley, W.; Tarrant, J.; Tilley, K.; Watson, S.; Wilson, A.; Forrest, D.; Soler, F. J. P.; Walaron, K.; Cooke, P.; Gamet, R.; Alekou, A.; Apollonio, M.; Barber, G.; Beuselinck, R.; Clark, D.; Clark, I.; Colling, D.; Dobbs, A.; Dornan, P.; Fayer, S.; Fish, A.; Hare, R.; Greenwood, S.; Jamdagni, A.; Kasey, V.; Khaleeq, M.; Leaver, J.; Long, K.; McKigney, E.; Matsushita, T.; Pasternak, J.; Sashalmi, T.; Savidge, T.; Takahashi, M.; Blackmore, V.; Carlisle, T.; Cobb, J. H.; Lau, W.; Rayner, M.; Tunnell, C. D.; Witte, H.; Yang, S.; Booth, C. N.; Hodgson, P.; Howlett, L.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.; Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Ellis, M.; Kyberd, P.; Littlefield, M.; Nebrensky, J. J.; Bross, A. D.; Geer, S.; Neuffer, D.; Moretti, A.; Popovic, M.; Cummings, M. A. C.; Roberts, T. J.; DeMello, A.; Green, M. A.; Li, D.; Virostek, S.; Zisman, M. S.; Freemire, B.; Hanlet, P.; Huang, D.; Kafka, G.; Kaplan, D. M.; Snopok, P.; Torun, Y.; Blot, S.; Kim, Y. K.; Bravar, U.; Onel, Y.; Cline, D.; Fukui, Y.; Lee, K.; Yang, X.; Rimmer, R. A.; Cremaldi, L. M.; Gregoire, G.; Hart, T. L.; Sanders, D. A.; Summers, D. J.; Coney, L.; Fletcher, R.; Hanson, G. G.; Heidt, C.; Gallardo, J.; Kahn, S.; Kirk, H.; Palmer, R. B.

    2012-05-01

    The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

  18. Upgrade of the beam transport lines and the beam-abort system and development of a tune compensator in KEKB

    Science.gov (United States)

    Iida, Naoko; Kikuchi, Mitsuo; Mimashi, Toshihiro; Nakayama, Hisayoshi; Sakamoto, Yutaka; Satoh, Kotaro; Takasaki, Seiji; Tawada, Masafumi

    2013-03-01

    The KEKB collider achieved a maximum peak luminosity of 2.1×1034 cm-2 s-1 and an integrated luminosity of 1 ab-1 in its ten-year operation. Behind these glorious records there have been uncountable improvements in every subsystem. This paper describes the improvements in the beam transport line, injection kickers, septum magnets, the beam-abort system, and a newly developed pulsed-quadrupole system in detail.

  19. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Science.gov (United States)

    Braccini, Saverio

    2013-04-01

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few μA for radioisotope production, as well as for both pulsed and continuous beams.

  20. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, Saverio [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2013-04-19

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few {mu}A for radioisotope production, as well as for both pulsed and continuous beams.

  1. Design of the prototype of a beam transport line for handling and selection of low energy laser-driven beams

    Science.gov (United States)

    Schillaci, F.; Maggiore, M.; Cirrone, G. A. P.; Cuttone, G.; Pisciotta, P.; Costa, M.; Rifuggiato, D.; Romano, F.; Scuderi, V.

    2016-11-01

    A first prototype of transport beam-line for laser-driven ion beams to be used for the handling of particles accelerated by high-power laser interacting with solid targets has been realized at INFN. The goal is the production of a controlled and stable beam in terms of energy and angular spread. The beam-line consists of two elements: an Energy Selection System (ESS), already realized and characterized with both conventional and laser-accelerated beams, and a Permanent Magnet Quadrupole system (PMQ) designed, in collaboration with SIGMAPHI (Fr), to improve the ESS performances. In this work a description of the ESS system and some results of its characterization with conventional beams are reported, in order to provide a complete explanation of the acceptance calculation. Then, the matching with the PMQ system is presented and, finally, the results of preliminary simulations with a realistic laser-driven energy spectrum are discussed demonstrating the possibility to provide a good quality beam downstream the systems.

  2. In-line E-beam metrology and defect inspection: industry reflections, hybrid E-beam opportunities, recommendations and predictions

    Science.gov (United States)

    Solecky, Eric; Rasafar, Allen; Cantone, Jason; Bunday, Benjamin; Vaid, Alok; Patterson, Oliver; Stamper, Andrew; Wu, Kevin; Buengener, Ralf; Weng, Weihao; Dai, Xintuo

    2017-03-01

    At SPIE 2013 in Metrology, Inspection, and Process Control for Microlithography an invited paper was published titled "In-line E-beam wafer metrology and defect inspection: the end of an era for image-based critical dimensional metrology? New life for defect inspection". Three years have passed and numerous developments have occurred as predicted in this paper. The development of E-beam tools that can concurrently handle metrology and defect applications is one of the primary developments. In this paper, the capabilities of these new E-beam tools and their current use cases will be discussed in the areas of Critical Dimension Uniformity (CDU), In-die overlay, Hot spot and Physical defect inspection. Emphasis will be placed on use cases where "massive" CDU data is collected in order to increase yield learning for manufacturing (14nm) and decrease cycles of learning for development (7nm). Additionally, some of the other subject material from the previous publication will also be discussed such as the current state of E-beam critical dimension image fidelity and physical defect detection capabilities. Lastly, future directions and opportunities for In-line E-beam including Multi-beam and/or Multi-column E-beam will be discussed.

  3. Visualization and on line monitoring of geometric parameters of beams at KSRS

    CERN Document Server

    Ioudin, L; Potlovsky, K; Rezvov, V

    2001-01-01

    On the basis of developed hardware and software we investigate the opportunity of on line registration of geometric parameters of low intensity SR beam and electron beams in single shot mode. Ionization and luminescence detectors form real optic image of a beam cross section. The image is registered by a TV camera, digitized and processed by a computer. Gray scale image and profiles of a beam are represented. Accumulation and statistic processing of the data give the possibility to increase the sensitivity of the hardware and to calculate the average position of the beam gravity center, dispersion and statistic uncertainty.

  4. A Monitor and Control System for the Synchrotron Radiation Beam Lines at DAΦNE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Three synchrotron radiation beam lines have been built on DAΦNE,the Frascati electron-positron accelerator.It is Possible to monitor and control all the elements on the beam lines using a modular network distributed I/O system by National Instrunments (FieldPoint) with Bridge VIEW/Lab VIEW programs,Two of these beam lines have radiation safety problems solved by two independent and redundant systems,using mechanical switches ,and S7-200 PLC's by Siemens.In this article our solution will be described in details.

  5. Fabrication of patterned mirror modules for generating laser line beams

    Science.gov (United States)

    Lee, Changyun; Kim, Taeggyum; Hong, Sangsu; Kim, Baekyun

    2008-02-01

    A method for fabricating Ag coated beam splitter is reported. This is showing specific patterned transmittance by immersing glass substrates in the mixture of H IISO 4 and H IIO II to make negatively charged oxygen sites at silica surface and then in ethanolic solutions of AgNO 3 and butylamine. We controlled the soaking time and molar ratios of the mixture of AgNO 3 and butylamine to pattern % transmittance of electroless coated glass surface. Finally, we made a functionalized beam splitters showing step function like transmittance and applied this to make multiple laser beams for display and laser machining.

  6. Laser beams as fiducial lines in bubble chambers

    CERN Document Server

    Leutz, H; Klamann, H; Muuss, H; Schmelzer, C

    1971-01-01

    It is proposed to base the fiduciary system of large volume bubble chambers on laser beams originating from theodolite-fixed positions and thus traversing the liquid at well defined space coordinates. From a series of experiments some important conditions for this proposal have been established: Rayleigh-scattering on molecular concentration fluctuations in the chamber liquid is responsible for the visibility of laser beams which can be photographed under angles up to 90 degrees within reasonable exposures. Small-angle random deflections of the laser beam were observed which are due to thermal turbulence in the chamber liquid.

  7. Development of pulsed positron beam line with compact pulsing system

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Masaki, E-mail: maekawa.masaki@jaea.go.jp [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Kawasuso, Atsuo [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2012-01-01

    We have developed a pulsed slow positron beam with a pulse width of less than 200 ps and a period of 25 ns. The beam apparatus is composed of a Munich-type pre-buncher, a chopper and a buncher. Instead of the conventional RF cavity, a simple double-cylinder electrode is used for the buncher. The beam will be used for positron lifetime measurements. The time resolution of the whole system including lifetime measurement circuits is 250 ps, which is adequate for studying semiconductors and metals.

  8. Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guimei [Peking Univ., Beijing (China)

    2011-12-31

    Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam

  9. Transmission line icing prediction based on DWT feature extraction

    Science.gov (United States)

    Ma, T. N.; Niu, D. X.; Huang, Y. L.

    2016-08-01

    Transmission line icing prediction is the premise of ensuring the safe operation of the network as well as the very important basis for the prevention of freezing disasters. In order to improve the prediction accuracy of icing, a transmission line icing prediction model based on discrete wavelet transform (DWT) feature extraction was built. In this method, a group of high and low frequency signals were obtained by DWT decomposition, and were fitted and predicted by using partial least squares regression model (PLS) and wavelet least square support vector model (w-LSSVM). Finally, the final result of the icing prediction was obtained by adding the predicted values of the high and low frequency signals. The results showed that the method is effective and feasible in the prediction of transmission line icing.

  10. Monitoring the extracted proton beam at the SPS

    CERN Multimedia

    1977-01-01

    Fluorescent screens in front of the target positions allow a precise adjustement in front of them. A similar photo was recorded at the beam dump at the beam injection into the SPS, see Weekly Bulletin of April 1976.

  11. Transport and dosimetric solutions for the ELIMED laser-driven beam line

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Romano, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Scuderi, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Amato, A. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Candiano, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); Cuttone, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Giove, D. [INFN Sezione di Milano, Via Celoria 16, Milano (Italy); Korn, G.; Krasa, J. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Leanza, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Manna, R. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Maggiore, M. [INFN-LNL, Viale dell' Universitá 2 - 35020 Legnaro (PD) (Italy); Marchese, V. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Margarone, D. [Institute of Physics ASCR, v.v.i. (FZU), ELI-Beamlines Project, Na Slovance 2, 182 21 Prague (Czech Republic); Milluzzo, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Universitá degli Studi di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Petringa, G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Sabini, M.G. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Azienda Ospedaliera Cannizzaro, Via Messina 829 - 95100 Catania (Italy); Schillaci, F. [INFN-LNS, Via S. Sofia 62 - 95125 Catania (Italy); Medical Physics School, University of Catania, Via S. Sofia 64 - 95125 Catania (Italy); and others

    2015-10-01

    Within 2017, the ELIMED (ELI-Beamlines MEDical applications) transport beam-line and dosimetric systems for laser-generated beams will be installed at the ELI-Beamlines facility in Prague (CZ), inside the ELIMAIA (ELI Multidisciplinary Applications of laser–Ion Acceleration) interaction room. The beam-line will be composed of two sections: one in vacuum, devoted to the collecting, focusing and energy selection of the primary beam and the second in air, where the ELIMED beam-line dosimetric devices will be located. This paper briefly describes the transport solutions that will be adopted together with the main dosimetric approaches. In particular, the description of an innovative Faraday Cup detector with its preliminary experimental tests will be reported.

  12. Parasitic slow extraction of extremely weak beam from a high-intensity proton rapid cycling synchrotron

    Science.gov (United States)

    Zou, Ye; Tang, Jingyu; Yang, Zheng; Jing, Hantao

    2014-02-01

    This paper proposes a novel method to extract extremely weak beam from a high-intensity proton rapid cycling synchrotron (RCS) in the parasitic mode, while maintaining the normal fast extraction. The usual slow extraction method from a synchrotron by employing third-order resonance cannot be applied in a high-intensity RCS due to a very short flat-top at the extraction energy and the strict control on beam loss. The proposed parasitic slow extraction method moves the beam to scrape a scattering foil prior to the fast beam extraction by employing either a local orbit bump or momentum deviation or their combination, so that the halo part of the beam will be scattered. A part of the scattered particles will be extracted from the RCS and guided to the experimental area. The slow extraction process can last about a few milliseconds before the beam is extracted by the fast extraction system. The method has been applied to the RCS of China Spallation Neutron Source. With 1.6 GeV in the extraction energy, 62.5 μA in the average current and 25 Hz in the repetition rate for the RCS, the proton intensity by the slow extraction method can be up to 2×104 protons per cycle or 5×105 protons per second. The extracted beam has also a good time structure of approximately uniform in a spill which is required for many applications such as detector tests. Detailed studies including the scattering effect in the foil, the local orbit bump by the bump magnets and dispersive orbit bump by modifying the RF pattern, the multi-particle simulations by ORBIT and TURTLE codes, and some technical features for the extraction magnets are presented.

  13. Measurement of Velocity Distribution in Atomic Beam by Diode Laser with Narrow Line width

    Institute of Scientific and Technical Information of China (English)

    CHEN Jingbiao; WANG Fengzhi; YANG Donghai; WANG YiQiu

    2001-01-01

    In this paper, by using the detecting laser beam interacts with the atomic beam at a sharp angle and the Doppler frequency shift effect, the velocity distribution in cesium atomic beam is measured with a diode laser of narrow linewidth of 1 MHz. The effects of the atomic natural line width and cycling transition detecting factor on the measured results have been analyzed. Finally, the measured results have been compared with the theoretical calculation.

  14. A feasibility study of H{sup -} beam extraction technique using YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Meigo, Shin-ichiro; Hasegawa, Kazuo; Ikeda, Yujiro; Oigawa, Hiroyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Aoki, Nobutada [Toshiba Power System Co., Ltd. (Japan); Nakagawa, Satoshi [Toshiba Co., Tokyo (Japan)

    2002-12-01

    Under a framework of JAERI-KEK joint project of high intensity proton accelerator, as for research and develop of the accelerator driven nuclear transmutation of the long lived radioactive nuclide, it is planed to built the Transmutation Physics Experiment Facility (TEF-P) and the Transmutation Engineering Experiment Facility (TEF-E). The TEF-P is used for the experiments for subcritical system coupled with a spallation neutron target bombarded with 600-MeV proton beam accelerated by the LINAC. To limit the maximum thermal power less than 500 W at the TEF-P, an incident beam power should be less than 10 W. On the contrary, at the TEF-E, high power beam of 200 kW is requested. Both high and low power beams are demanded for the transmutation facilities. It is difficult to deliver a low power beam to the TEF-P. Conventional beam extraction technique with a thin foil, is not desirable because the scattering of the beam at the foil requires the massive shield. Therefore, we study a new technique to extract a small portion of the beam precisely from the high intensity beam by using a laser beam. By a laser beam, H{sup -} in the beam from LINAC is partially changed to H{sup 0} beam so that a low current H{sup 0} beam can be obtained. As the cross section of the charge exchange reaction for H{sup -} ions has a peak around at a wave length of 1 {mu}m for photons, YAG laser is suitable for this charge exchange because of its 1.06 {mu}m wave length. It is derived that 10 W beam for 600-MeV proton can be extracted by the YAG laser with power of 2 J for each pulse of 25 Hz. By this technique, the pulse width for the extracted beam can be controlled by changing the time width of laser irradiation. When a charge exchanger having the beam collide point existing in straight section, a background beam current of projectile, however, will be increased due to the interaction with the residual gas in the beam duct. Thus, a charge exchanger is devised having the beam collide point in a

  15. A transverse emittance and acceptance measurement system in a low-energy beam transport line

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, H., E-mail: kashiwagi.hirotsugu@jaea.go.jp; Miyawaki, N.; Kurashima, S.; Okumura, S. [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of {sup 16}O{sup 6+} from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.

  16. Status of the SPES-charge breeder (SPES-CB) and its beam line at INFN-LNL

    Energy Technology Data Exchange (ETDEWEB)

    Galatá, Àlessio; Comunian, M. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Bellan, L. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Dipartimento di Fisica e Astronomia, Universitá degli Studi di Padova e Sezione INFN, Padova (Padova) (Italy); Maggiore, M.; Patti, G.; Roncolato, C.; Bisoffi, G. [INFN-Laboratori Nazionali di Legnaro, Viale dell’Universitá 2, 35020 Legnaro, Padova (Italy); Russo, A.D.; Calabretta, L. [INFN-Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Angot, J.; Lamy, T. [LPSC – Université Grenoble Alpes – CNRS/IN2P3, 53 rue des Martyrs, 38026 Grenoble Cedex (France)

    2016-06-01

    The Selective Production of Exotic Species (SPES) facility is under construction at INFN-LNL: aim of this project is the production, ionization and post-acceleration of radioactive ions to perform forefront research in nuclear physics. Radioactive species will be produced by fissions induced by a proton beam impinging on an UC{sub x} target: the proton beam will be delivered by a room temperature cyclotron (built by the Best Company) with a maximum energy of 40 MeV and 0.25 mA of maximum current. The radioactive species produced in the Target-Ion-Source system, extracted as a 1+ beam, cooled in a RFQ-cooler and purified from the isobars contaminants through a High Resolution Mass Spectrometer (HRMS). In order to allow post acceleration with the superconducting linac ALPI at INFN-LNL (up to 10 MeV/A for A/q = 7), an ECR-based charge breeding technique (ECR-CB) was chosen: in particular the SPES-CB was developed by the LPSC Grenoble on the basis of the Phoenix booster. The SPES-CB will be equipped with a complete test bench, totally integrated with the SPES beam line: in particular, in order to avoid beam contaminations induced by the impurities present inside the SPES-CB, and to have high transmission for a beam of very low intensity, special attention was paid not only to the transport efficiency but also to the resolution of the spectrometer downstream the charge breeder, with the design of a Medium Resolution Mass Spectrometer (MRMS). In the following paper the technical aspects connected with SPES-CB, its beam line and the transport of highly charged radioactive ions will be described.

  17. Status of the SPES-charge breeder (SPES-CB) and its beam line at INFN-LNL

    Science.gov (United States)

    Galatá, Àlessio; Comunian, M.; Bellan, L.; Maggiore, M.; Patti, G.; Roncolato, C.; Bisoffi, G.; Russo, A. D.; Calabretta, L.; Angot, J.; Lamy, T.

    2016-06-01

    The Selective Production of Exotic Species (SPES) facility is under construction at INFN-LNL: aim of this project is the production, ionization and post-acceleration of radioactive ions to perform forefront research in nuclear physics. Radioactive species will be produced by fissions induced by a proton beam impinging on an UCx target: the proton beam will be delivered by a room temperature cyclotron (built by the Best Company) with a maximum energy of 40 MeV and 0.25 mA of maximum current. The radioactive species produced in the Target-Ion-Source system, extracted as a 1+ beam, cooled in a RFQ-cooler and purified from the isobars contaminants through a High Resolution Mass Spectrometer (HRMS). In order to allow post acceleration with the superconducting linac ALPI at INFN-LNL (up to 10 MeV/A for A/q = 7), an ECR-based charge breeding technique (ECR-CB) was chosen: in particular the SPES-CB was developed by the LPSC Grenoble on the basis of the Phoenix booster. The SPES-CB will be equipped with a complete test bench, totally integrated with the SPES beam line: in particular, in order to avoid beam contaminations induced by the impurities present inside the SPES-CB, and to have high transmission for a beam of very low intensity, special attention was paid not only to the transport efficiency but also to the resolution of the spectrometer downstream the charge breeder, with the design of a Medium Resolution Mass Spectrometer (MRMS). In the following paper the technical aspects connected with SPES-CB, its beam line and the transport of highly charged radioactive ions will be described.

  18. Fast beam cut-off method in RF-knockout extraction for spot-scanning

    CERN Document Server

    Furukawa, T

    2002-01-01

    An irradiation method with magnetic scanning has been developed in order to provide accurate irradiation even for an irregular target shape. The scanning method has strongly required a lower ripple of the beam spill and a faster response to beam-on/off in slow extraction from a synchrotron ring. At HIMAC, RF-knockout extraction has utilized a bunched beam to reduce the beam-spill ripple. Therefore, particles near the resonance can be spilled out from the separatrices by synchrotron oscillation as well as by a transverse RF field. From this point of view, a fast beam cut-off method has been proposed and verified by both simulations and experiments. The maximum delay from the beam cut-off signal to beam-off has been improved to around 60 mu s from 700 mu s by a usual method. Unwanted dose has been considerably reduced by around a factor of 10 compared with that by the usual method.

  19. Measurements of an ion beam diameter extracted into air through a large-bore metal capillary

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Y.; Umigishi, M. [Graduate School of Humanities and Sciences, Nara Women’s University, Nara 630-8506 (Japan); Ishii, K.; Ogawa, H. [Department of Physics, Nara Women’s University, Nara 630-8506 (Japan)

    2015-07-01

    To extract an ion beam into air, the technique using a single macro-capillary has been paid attention. We have expanded the bore of the metal capillary up to 500 μm∅ inlet diameter to increase the beam intensity and have measured the intensity distributions of the extracted 3 MeV proton beam. Furthermore, we have tilted the capillary angle and measured the intensity distributions of the ion beam. In this article, we will present the experimental results together with the simulation which takes the tilt angles of the capillary into account.

  20. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...... with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix...

  1. Extraction characteristics of a low-energy ion beam system with a remote plasma chamber

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M. R., E-mail: mrvasquez@coe.upd.edu.ph [Department of Mining, Metallurgical, and Materials Engineering, College of Engineering, University of the Philippines, Diliman, Quezon City 1101 (Philippines); Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2016-02-15

    Low-energy argon beams were extracted from a dual-chamber ion source system. The first chamber is a quartz cylinder where dense inductively coupled plasmas were produced using 13.56 MHz radio frequency (rf) power. The discharge was driven into an adjacent chamber which acts as a reservoir for ion beam extraction using a dual-electrode extractor configuration. Extraction of ions from the second chamber with energies in the 100 eV range was achieved while minimizing fluctuations induced by the rf signal. A custom-built retarding potential analyzer was used to analyze the effectiveness of ion beam transport using the remote plasma chamber. Well-defined beams were extracted between 60 and 100 V extraction potentials at 50–100 W rf powers. An increase in rf power resulted in an increase in average ion energy, increase in ion current density while the energy spread remains constant.

  2. Layering-based Breakpoint Handling in Contour Line Extraction

    Institute of Scientific and Technical Information of China (English)

    CHEN Dan; LONG Yi; CAI Jinhua

    2003-01-01

    This paper deals withthe automatic connection of contourlines extracted from a scanned browngeographical map. For the variety oftopographical elements contained on amap, the factors causing the interrup-tion of contour line are also multiform,which make the connection task verydifficult. On the basis of separatingthose elements always making the con-tours break and regarding them as ref-erent layers, a layering-based methodis presented. The purpose is to takeinto account property information (likeinclination and configuration) of con-tour lines when they come across otherdifferent symbols, such as gully, cliff,dry land and elevation annotation etc.In this paper, the authors propose thatit should be far more effective and di-rect to adopt different algorithmic op-erators to different factors than usingsingle one operator to all.

  3. Molecularly imprinted polymers for on-line extraction techniques.

    Science.gov (United States)

    Moein, Mohammad M; Abdel-Rehim, Mohamed

    2015-01-01

    Recent years have seen an increasing interest in the use of molecularly imprinted polymers (MIPs) as a sorbent for different extraction methods and this is due to its high selectivity. The MIP is designed to show specificity for the analyte of interest. Moreover, MIPs show physical robustness, resistance to high temperatures and pressures, and stability in the presence of acids, bases and a wide range of organic solvents. In the present article, various novel sample preparation techniques which MIPs applied as sorbent and on-line connected with analytical instruments were highlighted and discussed. The future aspects of MIPs as well were described.

  4. Interleaving of beam lines inside the PS tunnel

    CERN Multimedia

    1983-01-01

    View against the direction of the proton beams. The PS ring (section 26) is on the left. The injection tunnel for LEAR leaving from here has increased the trafic in this already busy area where the two Linacs and the transfer tunnel leading to the SPS, ISR and AA join the PS ring (cf. photo 7802260, 7802261, Annual Report 1981, p. 89, fig. 12).

  5. Status of the PXIE Low Energy Beam Transport Line

    Energy Technology Data Exchange (ETDEWEB)

    Prost, Lionel [Fermilab; Andrews, Richard [Fermilab; Chen, Alex [Fermilab; Hanna, Bruce [Fermilab; Scarpine, Victor [Fermilab; Shemyakin, Alexander [Fermilab; Steimel, Jim [Fermilab; D' Arcy, Richard [University Coll. London

    2014-07-01

    A CW-compatible, pulsed H- superconducting RF linac (a.k.a. PIP-II) is envisaged as a possible path for upgrading Fermilab’s injection complex [1]. To validate the concept of the front-end of such machine, a test accelerator (a.k.a. PXIE) [2] is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2m-long LEBT, a 2.1 MeV CW RFQ, and a MEBT that feeds the first cryomodule. In addition to operating in the nominal CW mode, the LEBT should be able to produce a pulsed beam for both PXIE commissioning and modelling of the front-end nominal operation in the pulsed mode. Concurrently, it needs to provide effective means of inhibiting beam as part of the overall machine protection system. A peculiar feature of the present LEBT design is the capability of using the ~1m-long section immediately preceding the RFQ in two regimes of beam transport dynamics: neutralized and space charge dominated. This paper introduces the PXIE LEBT, reports on the status of the ion source and LEBT installation, and presents the first beam measurements.

  6. Photon backgrounds at the CLIC interaction point due to losses in the post-collision extraction line

    CERN Document Server

    Salt, M D; Elsener, K; Ferrari, A

    2010-01-01

    The CLIC beam delivery system focuses 1.5~TeV electron and positron beams to a nanometre-sized cross section when colliding them at the interaction point (IP). The intense focusing leads to large beam-beam effects, causing the production of beamstrahlung photons, coherent and incoherent $e^+e^-$ pairs, as well as a significant disruption of the main beam. The transport of the post-collision beams requires a minimal loss extraction line, with high acceptance for energy deviation and divergence. The current design includes vertical bends close to the IP in order to separate the charged particles with a sign opposite to the main beam into a diagnostic-equipped intermediate dump, whilst transporting the photons and the main beam to the final dump. Photon and charged particle losses on magnet masks and dumps result in a complex radiation field and IP background particle fluxes. In this paper, the electromagnetic backgrounds at the IP arising from the losses occurring closest to the collision point are calculated.

  7. Design of the low energy beam transport line for the China spallation neutron source

    Institute of Scientific and Technical Information of China (English)

    LI Jin-Hai; OUYANG Hua-Fu; FU Shi-Nian; ZHANG Sua-Shun; HE Wei

    2008-01-01

    The design of the China Spallation Neutron Source (CSNS) low-energy beam transport (LEBT) line, which locates between the ion source and the radio-frequency quadrupole (RFQ), has been completed with the TRACE3D code. The design aims at perfect matching, primary chopping, a small emittance growth and sufficient space for beam diagnostics. The line consists of three solenoids, three vacuum chambers, two steering magnets and a pre-chopper. The total length of LEBT is about 1.74 m. This LEBT is designed to transfer 20 mA of H-pulsed beam from the ion source to the RFQ. An induction cavity is adopted as the pre-chopper.The electrostatic octupole steerer is discussed as a candidate. A four-quadrant aperture for beam scraping and beam position monitoring is designed.

  8. Modeling of direct beam extraction for a high-charge-state fusion driver

    Science.gov (United States)

    Anderson, O. A.; Grant Logan, B.

    A newly proposed type of multicharged ion source offers the possibility of an economically advantageous high-charge-state fusion driver. Multiphoton absorption in an intense uniform laser focus can give multiple charge states of high purity, simplifying or eliminating the need for charge-state separation downstream. Very large currents (hundreds of amperes) can be extracted from this type of source. Several arrangements are possible. For example, the laser plasma could be tailored for storage in a magnetic bucket, with beam extracted from the bucket. A different approach, described in this report, is direct beam extraction from the expanding laser plasma. We discuss extraction and focusing for the particular case of a 4.1 MV beam of Xe 16+ ions. The maximum duration of the beam pulse is limited by the total charge in the plasma, while the practical pulse length is determined by the range of plasma radii over which good beam optics can be achieved. The extraction electrode contains a solenoid for beam focusing. Our design studies were carried out first with an envelope code and then with a self-consistent particle code. Results from our initial model showed that hundreds of amperes could be extracted, but that most of this current missed the solenoid entrance or was intercepted by the wall and that only a few amperes were able to pass through. We conclude with an improved design which increases the surviving beam to more than 70 A.

  9. Status of the ELIMED multidisciplinary and medical beam-line at ELI-Beamlines

    Science.gov (United States)

    Romano, F.; Cirrone, G. A. P.; Cuttone, G.; Schillaci, F.; Scuderi, V.; Amico, A.; Candiano, G.; Giordanengo, S.; Guarachi, L. F.; Korn, G.; Larosa, G.; Leanza, R.; Manna, R.; Marchese, V.; Marchetto, F.; Margarone, D.; Milluzzo, G.; Petringa, G.; Pipek, J.; Sacchi, R.; Vignati, A.

    2017-01-01

    Nowadays, one of the biggest challenges consists in using high intensity laser-target interaction to generate high-energy ions for medical purposes, eventually replacing the old paradigm of acceleration characterized by huge and complex machines. In order to investigate the feasibility of using laser-driven ion beams for multidisciplinary application, a dedicated beam transport line will be installed at the ELI-Beamlines facility in Prague (CZ), as a part of the User-oriented ELIMAIA beam-line dedicated to ion acceleration and their potential applications. The beam-line section dedicated to transport and dosimetric endpoints is called ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) and will be developed by the INFN-LNS.

  10. Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility

    CERN Document Server

    Gencer, A.; Efthymiopoulos, I.; Yiğitoğlu, M.

    2016-01-01

    Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between View the MathML source10μA and View the MathML source1.2mA. The beam kinetic energy is suitable for irradiation tests, however the beam current is high and therefore the flux must be lowered. We plan to build a defocusing beam line (DBL) in order to enlarge the beam size, reduce the flux to match the required specifications for the irradiation tests. Current design includes the beam transport and the final focusing magnets to blow up the beam. Scattering foils and a collimator is placed for the reduction of the beam ...

  11. Reprint of: Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    Energy Technology Data Exchange (ETDEWEB)

    Pan, R., E-mail: rui.pan@stfc.ac.uk [Accelerator Science and Technology Centre, Science and Technology Facilities Council, Darebsury Laboratory, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); School of Engineering, Physics and Mathematics, University of Dundee, Nethergate, Dundee DD1 4HN (United Kingdom); Jamison, S.P. [Accelerator Science and Technology Centre, Science and Technology Facilities Council, Darebsury Laboratory, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); Lefevre, T. [CERN, CH-1211 Geneva 23 (Switzerland); Gillespie, W.A. [School of Engineering, Physics and Mathematics, University of Dundee, Nethergate, Dundee DD1 4HN (United Kingdom)

    2016-09-11

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding (EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  12. Reprint of: Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

    Science.gov (United States)

    Pan, R.; Jamison, S. P.; Lefevre, T.; Gillespie, W. A.

    2016-09-01

    Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding (EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.

  13. The Joint Structural Biology Group beam lines at the ESRF: Modern macromolecular crystallography

    CERN Document Server

    Mitchell, E P

    2001-01-01

    Macromolecular crystallography has evolved considerably over the last decade. Data sets in under an hour are now possible on high throughput beam lines leading to electron density and, possibly, initial models calculated on-site. There are five beam lines currently dedicated to macromolecular crystallography: the ID14 complex and BM-14 (soon to be superseded by ID-29). These lines handle over five hundred projects every six months and demand is increasing. Automated sample handling, alignment and data management protocols will be required to work efficiently with this demanding load. Projects developing these themes are underway within the JSBG.

  14. A New Three-Dimensional Code for Simulation of Ion Beam Extraction: Ion Optics Simulator

    Institute of Scientific and Technical Information of China (English)

    JIN Dazhi; HUANG Tao; HU Quan; YANG Zhonghai

    2008-01-01

    A new thee-dimensional code, ion optics simulator (IOS), to simulate ion beam extraction is developed in visual C++ language. The theoretical model, the flowchart of code, and the results of calculation as an example are presented.

  15. Chemical investigations of isotope separation on line target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive ion beams (RIBs) are of significant interest in a number of applications. Isotope separation on line (ISOL) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to CO/sub x/ and NOmaterials are potential construction materials for the above-mentioned areas. Off-line and on-line tests have been performed using a gas thermochromatography setup with radioactive tracers. The experiments were performed at the production of tracers for atmospheric chemistry (PROTRAC) facility at the Paul Schener Institute in Villigen...

  16. Development of the beam extraction synchronization system at the Fermilab Booster

    Energy Technology Data Exchange (ETDEWEB)

    Seiya, K.; Chaurize, S.; Drennan, C.C.; Pellico, W.; Sullivan, T.; Triplett, A.K.; Waller, A.M.

    2015-11-01

    The new beam extraction synchronization control system called “Magnetic Cogging” was developed at the Fermilab Booster and it replaces a system called “RF Cogging” as part of the Proton Improvement Plan (PIP).[1] The flux throughput goal for the PIP is 2.2×10{sup 17} protons per hour, which is double the present flux. The flux increase will be accomplished by doubling the number of beam cycles which, in turn, will double the beam loss in the Booster accelerator if nothing else is done. The Booster accelerates beam from 400 MeV to 8 GeV and extracts it to the Main Injector (MI) or Recycler Ring (RR). Cogging controls the beam extraction gap position which is created early in the Booster cycle and synchronizes the gap to the rising edge of the Booster extraction kicker and the MI/RR injection kicker. The RF Cogging system controls the gap position by changing only the radial position of the beam thus limiting the beam aperture and creating beam loss due to beam scraping. The Magnetic Cogging system controls the gap position with the magnetic field of the dipole correctors while the radial position feedback keeps the beam on a central orbit. Also with Magnetic Cogging the gap creation can occur earlier in the Booster cycle when the removed particles are at a lower energy. Thus Magnetic Cogging reduces the deposited energy of the lost particles (beam energy loss) and results in less beam loss activation. Energy loss was reduced by 40% by moving the gap creation energy from 700 MeV to 400 MeV when the Booster Cogging system was switched from RF Cogging to Magnetic Cogging in March 2015.

  17. Changes to the Transfer Line Collimation System for the High-Luminosity LHC Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V. [CERN; Aberle, O. [CERN; Bracco, C. [CERN; Fraser, M. [CERN; Galleazzi, F. [CERN; Gianfelice-Wendt, E. [Fermilab; Kosmicki, A. [CERN; Maciariello, F. [CERN; Meddahi, M. [CERN; Nuiry, F. X. [CERN; Steele, G. [CERN; Velotti, F. [CERN

    2015-06-01

    The current LHC transfer line collimation system will not be able to provide enough protection for the high brightness beams in the high-luminosity LHC era. The new collimation system will have to attenuate more and be more robust than its predecessor. The active jaw length of the new transfer line collimators will therefore be 2.1 m instead of currently 1.2 m. The transfer line optics will have to be adjusted for the new collimator locations and larger beta functions at the collimators for absorber robustness reasons. In this paper the new design of the transfer line collimation system will be presented with its implications on transfer line optics and powering, maintainability, protection of transfer line magnets in case of beam loss on a collimator and protection of the LHC aperture.

  18. Changes to the Transfer Line Collimation System for the High-Luminosity LHC Beams

    CERN Document Server

    Kain, V; Bracco, C; Fraser, M; Galleazzi, F; Gianfelice-Wendt, E; Kosmicki, A; Maciariello, F; Meddahi, M; Nuiry, F X; Steele, G; Velotti, F

    2015-01-01

    The current LHC transfer line collimation system will not be able to provide enough protection for the high brightness beams in the high-luminosity LHC era. The new collimation system will have to attenuate more and be more robust than its predecessor. The active jaw length of the new transfer line collimators will therefore be 2.1 m instead of currently 1.2 m. The transfer line optics will have to be adjusted for the new collimator locations and larger beta functions at the collimators for absorber robustness reasons. In this paper the new design of the transfer line collimation system will be presented with its implications on transfer line optics and powering, maintainability, protection of transfer line magnets in case of beam loss on a collimator and protection of the LHC aperture.

  19. On the energy dependence of proton beam extraction with a bent crystal

    CERN Document Server

    Arduini, Gianluigi; Fidecaro, Giuseppe; Gyr, Marcel; Herr, Werner; Klem, J T; Mikkelsen, U; Weisse, E

    1998-01-01

    Proton beam extraction from the CERN SPS by means of a bent silicon crystal is reported at three different energies, 14 GeV, 120 GeV and 270 GeV. The experimental results are compared to computer simulations which contain a sound model of the SPS accelerator as well as the channeling phenomena in bent crystals. The overall energy dependence of crystal assisted proton beam extraction is understood and provides the basis to discuss such a scheme for future accelerators.

  20. The Challenge of Interfacing the Primary Beam Lines for the AWAKE Project at CERN

    CERN Document Server

    Bracco, C; Gschwendtner, E; Meddahi, M; Petrenko, A; Velotti, FM

    2014-01-01

    The Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) at CERN foresees the simultaneous operation of a proton, a laser and an electron beam. The first stage of the experiment will consist in proving the self-modulation, in the plasma, of a long proton bunch into micro-bunches. The success of this experiment requires an almost perfect concentricity of the proton and laser beam, over the full length of the plasma cell. The complexity of integrating the laser into the proton beam line and fulfilling the strict requirements in terms of pointing precision of the proton beam at the plasma cell are described. The second stage of the experiment foresees also the injection of electron bunches to probe the accelerating wakefields driven by the proton beam. Studies were performed to evaluate the possibility of injecting the electron beam parallel and with an offset to the beam axis. This option would imply that protons and electrons will have to share the last few meters of a common beam line. Issues and po...

  1. Proposal for a Multi-Use Test Beam Area in the SLAC B-Line

    CERN Document Server

    Emma, Paul; Erickson, Roger; Fieguth, Theodore; Seeman, John; Seryi, Andrei

    2005-01-01

    With the impending construction of the Linac Coherent Light Source (LCLS) at SLAC, displacing the well-used Final Focus Test Beam (FFTB) area, there is growing interest in developing a new test beam facility, available during LCLS operations and located in the old B-Line tunnel at the end of the linac. The success of the Sub-Picosecond Pulse Source (SPPS) and the desire to preserve this capacity suggests a new beamline with similar or improved electron beam quality, including bunch length compression to 10 microns. Beam availability during LCLS operations requires a new 1.2-km bypass line connecting the 2/3-point of the linac with the B-Line. A second operating mode, with LCLS not in use, involves a trajectory directly from the end of the linac to the B-line. This feature provides the highest beam quality at 30 GeV, and also allows a possible third operational mode by deflecting a few of the very high-brightness 120-Hz, 14-GeV LCLS bunches at low rate (1-10 Hz) into the B-line. Finally, linear collider resear...

  2. Modification and alignment of beam line of 10 MeV RF electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Barnwal, R; Ghodke, S R; Bhattacharjee, D; Kumar, M; Jayaprakash, D; Chindarkar, A R; Mishra, R L; Kumar, M; P, Dixit K; S, Acharya; Barje, S R; Lawangare, N K; C, Saroj P; Nimje, V T; Chandan, S; Tillu, A R; V, Sharma; Chavan, R B [Accelerator and Pulse Power Division, BARC, Mumbai, India-400085 (India); Dolas, S [Centre for Design and Manufacturing, BARC, Mumbai, India-400085 (India); Kulkarni, S Y [SAMEER, IIT Powai campus, Mumbai, India-400076 (India)], E-mail: rajesh_barc47@indiatimes.com (and others)

    2008-05-01

    A 10 MeV, 10 kW RF industrial Electron linac designed and developed at BARC is installed at the Electron Beam Center Kharghar, Navi Mumbai. The entire RF accelerator assembly consists of Electron gun, RF source, RF linac structure, Beam diagnostic chamber, Drift tube, Scanning magnet, Beam sensing aperture, Scan horn, and is spread over two floors at EBC. The paper discusses in detail about the alignment procedure adopted for the equipments of 10 MeV RF beamline. The complete electron beamline will be maintained under ultra high vacuum of the order of 10-7 torr. The paper discusses about the present problem of alignment, measurement technique of alignment, reason for misalignment, possible ways to solve the problem, equipment used for alignment, supports and arrestors, verification of alignment under vacuum.

  3. Modification & alignment of beam line of 10 MeV RF electron beam accelerator

    Science.gov (United States)

    Barnwal, R.; Ghodke, S. R.; Bhattacharjee, D.; Kumar, M.; Jayaprakash, D.; Chindarkar, A. R.; Mishra, R. L.; Dolas, S.; Kulkarni, S. Y.; Kumar, M.; P, Dixit K.; S, Acharya; Barje, S. R.; Lawangare, N. K.; C, Saroj P.; Nimje, V. T.; Chandan, S.; Tillu, A. R.; V, Sharma; Chavan, R. B.; V, Yadav; P, Roychowdhury; Mittal, K. C.; Chakravarthy, D. P.; Ray, A. K.

    2008-05-01

    A 10 MeV, 10 kW RF industrial Electron linac designed and developed at BARC is installed at the Electron Beam Center Kharghar, Navi Mumbai. The entire RF accelerator assembly consists of Electron gun, RF source, RF linac structure, Beam diagnostic chamber, Drift tube, Scanning magnet, Beam sensing aperture, Scan horn, and is spread over two floors at EBC. The paper discusses in detail about the alignment procedure adopted for the equipments of 10 MeV RF beamline. The complete electron beamline will be maintained under ultra high vacuum of the order of 10-7 torr. The paper discusses about the present problem of alignment, measurement technique of alignment, reason for misalignment, possible ways to solve the problem, equipment used for alignment, supports & arrestors, verification of alignment under vacuum

  4. Pulse-by-pulse multi-beam-line operation for x-ray free-electron lasers

    Directory of Open Access Journals (Sweden)

    Toru Hara

    2016-02-01

    Full Text Available The parallel operation of plural undulator beam lines is an important means of improving the efficiency and usability of x-ray free-electron laser facilities. After the installation of a second undulator beam line (BL2 at SPring-8 Angstrom compact free-electron laser (SACLA, pulse-by-pulse switching between two beam lines was tested using kicker and dc twin-septum magnets. To maintain a compact size, all undulator beam lines at SACLA are designed to be placed within the same undulator hall located downstream of the accelerator. In order to ensure broad tunability of the laser wavelength, the electron bunches are accelerated to different beam energies optimized for the wavelengths of each beam line. In the demonstration, the 30 Hz electron beam was alternately deflected to two beam lines and simultaneous lasing was achieved with 15 Hz at each beam line. Since the electron beam was deflected twice by 3° in a dogleg to BL2, the coherent synchrotron radiation (CSR effects became non-negligible. Currently in a wavelength range of 4–10 keV, a laser pulse energy of 100–150  μJ can be obtained with a reduced peak current of around 1 kA by alleviating the CSR effects. This paper reports the results and operational issues related to the multi-beam-line operation of SACLA.

  5. The Gas Flow from the Gas Attenuator to the Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.D.

    2010-12-03

    The gas leak from the gas attenuator to the main beam line of the Linac Coherent Light Source has been evaluated, with the effect of the Knudsen molecular beam included. It has been found that the gas leak from the gas attenuator of the present design, with nitrogen as a working gas, does not exceed 10{sup -5} torr x l/s even at the highest pressure in the main attenuation cell (20 torr).

  6. Computer simulation of 2-D and 3-D ion beam extraction and acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Ido, Shunji; Nakajima, Yuji [Saitama Univ., Urawa (Japan). Faculty of Engineering

    1997-03-01

    The two-dimensional code and the three-dimensional code have been developed to study the physical features of the ion beams in the extraction and acceleration stages. By using the two-dimensional code, the design of first electrode(plasma grid) is examined in regard to the beam divergence. In the computational studies by using the three-dimensional code, the axis-off model of ion beam is investigated. It is found that the deflection angle of ion beam is proportional to the gap displacement of the electrodes. (author)

  7. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Küchler, D

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  8. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V., E-mail: ville.aleksi.toivanen@cern.ch; Küchler, D. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-02-15

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  9. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Science.gov (United States)

    Toivanen, V.; Küchler, D.

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  10. Reduction of uncontrollable spilled beam in RF-knockout slow extraction

    Science.gov (United States)

    Mizushima, K.; Shirai, T.; Furukawa, T.; Sato, S.; Iwata, Y.; Noda, K.; Uchiyama, H.

    2009-07-01

    A 3D-scanning irradiation method gated with the patient's respiration has been developed for the new Heavy Ion Medical Accelerator treatment facility in Chiba. The RF-knockout slow-extraction method has been used for fast on/off switching of the beam from the synchrotron during scanning irradiation. However, a small amount of beam that remained just inside the separatrix spilled out even without the transverse RF field, and limits the controllable low beam rate. We proposed to apply another transverse RF field with a frequency component matched with the betatron frequency of particles near the stopband in addition to the original transverse RF field. The particles just inside the separatrix can be selectively extracted during the irradiation, and the uncontrollable spilled beam can be suppressed. The spilled beam was measured with the ion chamber, and was reduced to 0.4% compared to the original method.

  11. On-line Observation Of Electron Beam Bunches In The Large Storage Ring Of Kurchatov Srs

    CERN Document Server

    Ioudin, L I; Krylov, Y V; Rezvov, V A; Stirin, A I; Valentinov, A G; Yupinov, Y L

    2004-01-01

    A complex of instrumentation for visual quantitative estimation of electron beam bunches in the big storage ring of Kurchatov Synchrotron Radiation Centre (KSRC) is tested. The bunches pass through a cylindrical electrostatic sensor whose signal is recorded by a wide-band oscillograph. The TV camera reads the optical image of the signal from the oscillograph screen. The TV signal numbering board inputs the video image to the computer memory. The monitor displays the beam bunch structure. A special program provides on-line visualisation of bunch behaviour on the beam orbit. The images of beam structure and a series of images showing the beam behaviour in the regimes of accumulation, acceleration and in the stationary regime a full power are numbered and stored.

  12. A logarithmic processor for Beam Position Measurements applied to a Transfer Line at CERN

    CERN Document Server

    Schmickler, Hermann

    2001-01-01

    The transfer line from the CERN proton synchrotron (PS) to the super proton synchrotron (SPS) requires a new beam position measurement system in view of the LHC. In this line, the single passage of various beam types (up to 7), induces signals with a global signal dynamics of more than 100 dB and with a wide frequency spectral distribution. Logarithmic amplifiers, have been chosen as technical solution for the challenges described above. The paper describes the details of the adopted solutions to make beam position measurements, with a resolution down to few 10-4 of the full pickup aperture over more than 50 dB of the total signal dynamics. The reported performances has been measured on the series production cards, already installed into the machine and on one pickup in the transfer line.

  13. 1 to 2 GeV/c beam line for hypernuclear and kaon research

    Energy Technology Data Exchange (ETDEWEB)

    Chrien, R.E.

    1985-02-15

    A kaon beam line operating in the range from 1.0 to 2.0 GeV/c is proposed. The line is meant for kaon and pion research in a region hitherto inaccessible to experimenters. Topics in hypernuclear and kaon physics of high current interest include the investigation of doubly strange nuclear systems with the K/sup -/,K/sup +/ reaction, searching for dibaryon resonances, hyperon-nucleon interactions, hypernuclear ..gamma.. rays, and associated production of excited hypernuclei. The beam line would provide separated beams of momentum analyzed kaons at intensities greater than 10/sup 6/ particles per spill with a momentum determined to one part in a thousand. This intensity is an order of magnitude greater than that currently available. 63 references.

  14. Simulation and optimization of beam losses during continuous transfer extraction at the CERN Proton Synchrotron

    CERN Document Server

    Garcia, J B

    2011-01-01

    The proton beams used for the fixed target physics at the Super Proton Synchrotron (SPS) are extracted from the Proton Synchrotron ( PS) by a multiturn technique called continuous transfer (CT). During the CT extraction, large losses are observed in locations where the machine aperture should be large enough to accommodate the circulating beam. This limits the maximum intensity deliverable due to the induced stray radiation outside the PS tunnel. Scattered particles from the interaction with the electrostatic septum are identified as the possible source of these losses. This article presents a detailed study aiming to understand the origin of losses and propose possible cures. The simulations could reproduce accurately the beam loss pattern measured in real machine operation and determine the beam shaving, intrinsic to the extraction process, as the cause for the unexpected losses. Since these losses are unavoidable, the proposed solution implies a new optics scheme displacing the losses to a region with bett...

  15. Proton and Pb ion beam extraction experiments with bent crystals at the CERN-SPS

    CERN Document Server

    Elsener, K; Klem, J T; CERN. Geneva. SPS and LEP Division

    1997-01-01

    Extraction of particle beams from the CERN-SPS using bent silicon crystals is described. A summary of the early results is given. Emphasis is on the recent experiments, in particular on the energy dependence of proton extraction at 14, 120 and 270 GeV. 'U-shaped' crystals of different thickness and with a different miscut angle have been compared at 120 GeV. Non-linear excitation of the beam was used in one experiment, with the aim to achieve larger impact parameters - the results show a particular behaviour in the tails of the beam. Finally, the first experimental result on extraction of a 22 TeV fully stripped Pb ion beam with a bent crystal is also described.

  16. Successful beam test of the SPS-to-LHC transfer line TI2

    CERN Multimedia

    2007-01-01

    Image of the first beam spot on the last BTV screen traversed by the beam during the TI 2 test.At 12:03:47 on 28 October a beam passed down the 2.7 km of the new SPS-to-LHC transfer line TI 2 at the first attempt, to within some 50 m of the LHC tunnel. After initial tuning, a range of measurements was carried out with a low intensity proton beam and preliminary analyses look good. After the test, no increase in radiation levels was found in either the LHC or ALICE, and the zones were rapidly opened again for access. As from next year TI 2 will regularly transport a beam from the SPS to the LHC injection point of Ring 1, near Point 2 (ALICE). The TI 8 transfer line, which will bring particles from the SPS to the injection point in Ring 2, near Point 8 (LHCb), was commissioned successfully with low intensity beam in 2004. The two LHC injection lines have a combined length of 5.6 km and comprise some seven hundred warm magnets. While a...

  17. Simulation and Field Measurement of Quadrupole Magnets for KOMAC 20MeV Beam line

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B. H.; Kim, H. S.; Song, Y. G.; Kwon, H. J.; Cho, Y. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, quadrupole magnets the same as installed at the beam line simulated and analyzed for magnetic fields. Also quadrupole magnets will be measured field stability and evaluated reliability on long time operation. Control system consisted of Labview program and communication method consisted of Ethernet and Rs-232 with optical fiber for devices safety from high voltage and/or high current. As a results the DC power supply is controlled, magnetic fields data is acquired and coil temperature is measured. Magnetic field with hall sensor and temperature with K-type thermo-couple are measured with conversion factor using by voltmeter. Korea Multi-purpose Accelerator Complex (KOMAC) was developed at Gyeongju in Korea in 2012. KOMAC including a 50-keV ion source, a 3-MeV RFQ, and a 100-MeV DTL. And beam line consists of 20-MeV and 100-MeV for user. Proton beam transferred from the linac to the beam line using by dipole magnets and transferred proton beam focused and decreased beam loss and by quadrupole magnets.

  18. Accelerator and detector physics at the Bern medical cyclotron and its beam transport line

    Directory of Open Access Journals (Sweden)

    Auger Martin

    2016-03-01

    Full Text Available The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.

  19. Neutron beam line design of a white neutron source at CSNS

    Science.gov (United States)

    Jing, Hantao; Zhang, Liying; Tang, Jingyu; Ruan, Xichao; Ning, Changjun; Yu, Yongji; Wang, Pengcheng; Li, Qiang; Ren, Jie; Tang, Hongqing; Wang, Xiangqi

    2017-09-01

    China Spallation Neutron Source (CSNS), which is under construction, is a large scientific facility dedicated mainly for multi-disciplinary research on material characterization using neutron scattering techniques. The CSNS Phase-I accelerator will deliver a proton beam with an energy of 1.6 GeV and a pulse repetition rate of 25 Hz to a tungsten target, and the beam power is 100 kW. A white neutron source using the back-streaming neutrons through the incoming proton beam channel was proposed and is under construction. The back-streaming neutrons which are very intense and have good time structure are very suitable for nuclear data measurements. The white neutron source includes an 80-m neutron beam line, two experimental halls, and also six different types of spectrometers. The physics design of the beam line is presented in this paper, which includes beam optics and beam characterization simulations, with the emphasis on obtaining extremely low background. The first-batch experiments on nuclear data measurements are expected to be conducted in late 2017.

  20. Lessons from shielding retrofits at the LAMPF/LANSCE/PSR accelerator, beam lines and target facilities

    Energy Technology Data Exchange (ETDEWEB)

    Macek, R.J.

    1994-07-01

    The experience in the past 7 years to improve the shielding and radiation control systems at the Los Alamos Meson Physics Facility (LAMPF) and the Manuel Lujan Jr. Neutron Scattering Center (LANSCE) provides important lessons for the design of radiation control systems at future, high beam power proton accelerator facilities. Major issues confronted and insight gained in developing shielding criteria and in the use of radiation interlocks are discussed. For accelerators and beam lines requiring hands-on-maintenance, our experience suggests that shielding criteria based on accident scenarios will be more demanding than criteria based on routinely encountered beam losses. Specification and analysis of the appropriate design basis accident become all important. Mitigation by active protection systems of the consequences of potential, but severe, prompt radiation accidents has been advocated as an alternate choice to shielding retrofits for risk management at both facilities. Acceptance of active protection systems has proven elusive primarily because of the difficulty in providing convincing proof that failure of active systems (to mitigate the accident) is incredible. Results from extensive shielding assessment studies are presented including data from experimental beam spill tests, comparisons with model estimates, and evidence bearing on the limitations of line-of-sight attenuation models in complex geometries. The scope and significant characteristics of major shielding retrofit projects at the LAMPF site are illustrated by the project to improve the shielding beneath a road over a multiuse, high-intensity beam line (Line D).

  1. Design of the beam transport line and injection system of the compact storage ring for TTX

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In this article, we present the design of the beam transport line and injection system of the compact storage ring for the Tsinghua Thomson scattering X-ray (TTX) source. The layout of the beam transport line fits in with the limited available space. The injection system is simplified, consisting of only one single kicker; the stray field on the reference orbit is also reduced without the septum magnet. We choose a travelling wave kicker and present both 2D and 3D simulations for the structure design.

  2. Present Status And First Results of the Final Focus Beam Line at the KEK Accelerator Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bambade, P.; /Orsay /KEK, Tsukuba; Alabau Pons, M.; /Valencia U., IFIC; Amann, J.; /SLAC; Angal-Kalinin, D.; /Daresbury; Apsimon, R.; /Oxford U., JAI; Araki, S.; Aryshev, A.; /KEK, Tsukuba; Bai, S.; /Beijing, Inst. High Energy Phys.; Bellomo, P.; /SLAC; Bett, D.; /Oxford U., JAI; Blair, G.; /Royal Holloway, U. of London; Bolzon, B.; /Savoie U.; Boogert, S.; Boorman, G.; /Royal Holloway, U. of London; Burrows, P.N.; Christian, G.; Coe, P.; Constance, B.; /Oxford U., JAI; Delahaye, Jean-Pierre; /CERN; Deacon, L.; /Royal Holloway, U. of London; Elsen, E.; /DESY /Valencia U., IFIC /KEK, Tsukuba /Beijing, Inst. High Energy Phys. /Savoie U. /Fermilab /Ecole Polytechnique /KEK, Tsukuba /Kyungpook Natl. U. /KEK, Tsukuba /Pohang Accelerator Lab. /Kyoto U., Inst. Chem. Res. /Savoie U. /Daresbury /Tokyo U. /Royal Holloway, U. of London /Kyungpook Natl. U. /Pohang Accelerator Lab. /Tokyo U. /KEK, Tsukuba /SLAC /University Coll. London /KEK, Tsukuba /SLAC /Royal Holloway, U. of London /KEK, Tsukuba /Tokyo U. /SLAC /Tohoku U. /KEK, Tsukuba /Tokyo U. /Pohang Accelerator Lab. /Brookhaven /SLAC /Oxford U., JAI /SLAC /Orsay /KEK, Tsukuba /Oxford U., JAI /Orsay /Fermilab /Tohoku U. /Manchester U. /CERN /SLAC /Tokyo U. /KEK, Tsukuba /Oxford U., JAI /Hiroshima U. /KEK, Tsukuba /CERN /KEK, Tsukuba /Oxford U., JAI /Ecole Polytechnique /SLAC /Oxford U., JAI /Fermilab /SLAC /Liverpool U. /SLAC /Tokyo U. /SLAC /Tokyo U. /KEK, Tsukuba /SLAC /CERN

    2011-11-11

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  3. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, Jean-Pierre; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A -Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E -S; Kim, H -S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M -H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  4. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Bambade, P; Amann, J; Angal-Kalinin, D; Apsimon, R; Araki, S; Aryshev, A; Bai, S; Bellomo, P; Bett, D; Blair, G; Bolzon, B; Boogert, S; Boorman, G; Burrows, P N; Christian, G; Coe, P; Constance, B; Delahaye, J P; Deacon, L; Elsen, E; Faus-Golfe, A; Fukuda, M; Gao, J; Geffroy, N; Gianfelice-Wendt, E; Guler, H; Hayano, H; Heo, A Y; Honda, Y; Huang, J Y; Hwang, W H; Iwashita, Y; Jeremie, A; Jones, J; Kamiya, Y; Karataev, P; Kim, E S; Kim, H S; Kim, S H; Komamiya, S; Kubo, K; Kume, T; Kuroda, S; Lam, B; Lyapin, A; Masuzawa, M; McCormick, D; Molloy, S; Naito, T; Nakamura, T; Nelson, J; Okamoto, D; Okugi, T; Oroku, M; Park, Y J; Parker, B; Paterson, E; Perry, C; Pivi, M; Raubenheimer, T; Renier, Y; Resta-Lopez, J; Rimbault, C; Ross, M; Sanuki, T; Scarfe, A; Schulte, D; Seryi, A; Spencer, C; Suehara, T; Sugahara, R; Swinson, C; Takahashi, T; Tauchi, T; Terunuma, N; Tomas, R; Urakawa, J; Urner, D; Verderi, M; Wang, M H; Warden, M; Wendt, M; White, G; Wittmer, W; Wolski, A; Woodley, M; Yamaguchi, Y; Yamanaka, T; Yan, Y; Yoda, H; Yokoya, K; Zhou, F; Zimmermann, F; 10.1103/PhysRevSTAB.13.042801

    2010-01-01

    ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  5. High efficiency multi-pass proton beam extraction with a bent crystal at the SPS

    Science.gov (United States)

    Altuna, X.; Bussa, M. P.; Carboni, G.; Dehning, B.; Elsener, K.; Ferrari, A.; Fidecaro, G.; Freund, A.; Guinand, R.; Gyr, M.; Herr, W.; Klem, J.; Laffin, M.; Lanceri, L.; Mikkelsen, U.; Møller, S. P.; Scandale, W.; Tosello, F.; Uggerhøj, E.; Vuagnin, G.; Weisse, E.; Weisz, S.

    1995-02-01

    Recent measurements of 120 GeV proton extraction by means of a bent silicon crystal at the CERN-SPS accelerator are summarized. The existence of multi-pass extraction has been proven by blocking first-pass extraction: using a crystal covered with an amorphous layer, extracted beam with high efficiency was observed, which provides a direct proof for the importance of the multi-pass mechanism. This opens new possibilities in the design and optimization of a bent crystal extraction scheme.

  6. Characterization of a tagged $\\gamma$-ray beam line at the DA$\\Phi$NE Beam Test Facility

    CERN Document Server

    Cattaneo, P W; Boffelli, F; Bulgarelli, A; Buonomo, B; Chen, A W; D'Ammando, F; Froysland, T; Fuschino, F; Galli, M; Gianotti, F; Giuliani, A; Longo, F; Marisaldi, M; Mazzitelli, G; Pellizzoni, A; Prest, M; Pucella, G; Quintieri, L; Rappoldi, A; Tavani, M; Trifoglio, M; Trois, A; Valente, P; Vallazza, E; Vercellone, S; Zambra, A; Barbiellini, G; Caraveo, P; Cocco, V; Costa, E; De Paris, G; Del Monte, E; Di Cocco, G; Donnarumma, I; Evangelista, Y; Feroci, M; Ferrari, A; Fiorini, M; Labanti, C; Lapshov, I; Lazzarotto, F; Lipari, P; Mastropietro, M; Mereghetti, S; Morelli, E; Moretti, E; Morselli, A; Pacciani, L; Perotti, F; Piano, G; Picozza, P; Pilia, M; Porrovecchio, G; Rapisarda, M; Rubini, A; Sabatini, S; Soffitta, P; Striani, E; Vittorini, V; Zanello, D; Colafrancesco, S; Giommi, P; Pittori, C; Santolamazza, P; Verrecchia, F; Salotti, L

    2011-01-01

    At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $\\gamma$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $\\gamma$ rays. A tagged $\\gamma$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $\\gamma$ rays through Bremsstrahlung in a position-sensitive target. The $\\gamma$-ray energy is deduced by difference with the post-Bremsstrahlung electron energy \\cite{prest}-\\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the...

  7. The Very Low 1-9 GeV/c Tertiary Beam Extension of the H8 Beam Line of CERN SPS

    CERN Document Server

    Efthymiopoulos, Ilias

    2016-01-01

    The H8 beam line on the North Area of CERN SPS is a multipurpose experimental secondary particle beam able to transport particles of various types (hadrons, electrons, muons and ions) in a large momentum range from 10 GeV/c up to the top SPS energy (400 or 450 GeV/C). During the 2003-2004 shutdown the beam line was modi?fied in order to accommodate a new tertiary beam line, able to produce and transport particles in the momentum range of 1 to 9 GeV/c. Such low momentum hadron and electron particle beams are requested by the LHC experiments in order to calibrate various sub-detector systems. The design and first performance results from this new tertiary beam are described here.

  8. Upgrade to a programmable timing system for the KOMAC proton linac and multi-purpose beam lines

    Science.gov (United States)

    Song, Young-Gi

    2016-09-01

    The KOMAC facility consists of low-energy components, including a 50-keV ion source, a lowenergy beam transport (LEBT), a 3-MeV radio-frequency quadrupole (RFQ), and a 20-MeV drift tube linac (DTL), as well as high-energy components, including seven DTL tanks for the 100-MeV proton beam. The KOMAC includes ten beam lines, five for 20-MeV beams and five for 100-MeV beams. The peak beam current and the maximum beam duty are 20 mA and 24% for the 20-MeV linac and 20 mA and 8% for the 100-MeV linac, respectively. Four high-voltage convertor modulators are used. Each modulator drives two or three klystrons. The peak output power is 5.8 MW, and the average power is 520 kW with a duty of 9%. The pulse width and repetition rate are 1.5 ms and 60 Hz, respectively. Each component of the pulsed operation mode has a timing trigger signal with precision synchronization. A timing system for beam extraction and for diagnostic components is required to provide precise pulse signals synchronized with a 300-MHz RF reference frequency. In addition, the timing parameters should be capable of real-time changes in accordance with the beam power. The KOMAC timing system has been upgraded to a programmable Micro Research Finland (MRF) event timing system that is synchronized with the RF, AC main frequency and with the global positioning system (GPS) 1-PPS signal. The event timing system consists of an event generator (EVG) and an event receiver (EVR). The event timing system is integrated with the KOMAC control system by using experimental physics and industrial control system (EPICS) software. For preliminary hardware and software testing, a long operation test with a synchronization of 300-MHz RF reference and 60-Hz AC has been completed successfully. In this paper, we will describe the software implementation, the testing, and the installation of the new timing system.

  9. Validation of Monte-Carlo simulations with measurements at the ICON beam-line at SINQ

    Energy Technology Data Exchange (ETDEWEB)

    Giller, L. [LRS, Physics Department, Ecole Polytechnique Federal de Lausanne, CH-1015 Lausanne (Switzerland); Filges, U. [LDM, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)], E-mail: uwe.filges@psi.ch; Kuehne, G. [ASQ, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Wohlmuther, M. [ABE, GFA Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Zanini, L. [ASQ, NUM Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2008-02-11

    ICON is the new cold neutron imaging facility at the neutron spallation source SINQ. The ICON facility is placed at beam-line S52 with direct view to the cold liquid D{sub 2} moderator. The beam-line includes a 4.4 m long collimation section followed by a 11 m long flight path to the imaging system. The essential part of the collimation section is composed of six revolving drums and a variable aperture wheel. Depending on the investigated object, different apertures are used. Measurements have shown that each setup has a different spatial neutron flux distribution and specific beam profiles. Measured beam profiles have been used to validate results of simulations coupling the Monte-Carlo program MCNPX with the neutron ray-tracing program McStas. In a first step, MCNPX was used to calculate neutron spectra closed to the SINQ target, at the entrance of the collimation section. These results served as an input for McStas where the beam-line itself was simulated. In the present paper, experimental and theoretical results will be compared and discussed.

  10. Validation of Monte-Carlo simulations with measurements at the ICON beam-line at SINQ

    Science.gov (United States)

    Giller, L.; Filges, U.; Kühne, G.; Wohlmuther, M.; Zanini, L.

    2008-02-01

    ICON is the new cold neutron imaging facility at the neutron spallation source SINQ. The ICON facility is placed at beam-line S52 with direct view to the cold liquid D 2 moderator. The beam-line includes a 4.4 m long collimation section followed by a 11 m long flight path to the imaging system. The essential part of the collimation section is composed of six revolving drums and a variable aperture wheel. Depending on the investigated object, different apertures are used. Measurements have shown that each setup has a different spatial neutron flux distribution and specific beam profiles. Measured beam profiles have been used to validate results of simulations coupling the Monte-Carlo program MCNPX with the neutron ray-tracing program McStas. In a first step, MCNPX was used to calculate neutron spectra closed to the SINQ target, at the entrance of the collimation section. These results served as an input for McStas where the beam-line itself was simulated. In the present paper, experimental and theoretical results will be compared and discussed.

  11. Tailoring phase-space in neutron beam extraction

    Energy Technology Data Exchange (ETDEWEB)

    Weichselbaumer, S. [Heinz Maier-Leibnitz Zentrum und Physik-Department E21, Technische Universität München, Lichtenbergstr. 1, D-85748 Garching (Germany); Brandl, G. [Heinz Maier-Leibnitz Zentrum und Physik-Department E21, Technische Universität München, Lichtenbergstr. 1, D-85748 Garching (Germany); Physik-Department E21, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany); Georgii, R., E-mail: Robert.Georgii@frm2.tum.de [Heinz Maier-Leibnitz Zentrum und Physik-Department E21, Technische Universität München, Lichtenbergstr. 1, D-85748 Garching (Germany); Physik-Department E21, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany); Stahn, J. [Laboratory for Neutron Scattering, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Panzner, T. [Material Science and Simulations, Neutrons and Muons, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Böni, P. [Physik-Department E21, Technische Universität München, James-Franck-Str. 1, D-85748 Garching (Germany)

    2015-09-01

    In view of the trend towards smaller samples and experiments under extreme conditions it is important to deliver small and homogeneous neutron beams to the sample area. For this purpose, elliptic and/or Montel mirrors are ideally suited as the phase space of the neutrons can be defined far away from the sample. Therefore, only the useful neutrons will arrive at the sample position leading to a very low background. We demonstrate the ease of designing neutron transport systems using simple numeric tools, which are verified using Monte-Carlo simulations that allow taking into account effects of gravity and finite beam size. It is shown that a significant part of the brilliance can be transferred from the moderator to the sample. Our results may have a serious impact on the design of instruments at spallation sources such as the European Spallation Source (ESS) in Lund, Sweden.

  12. RESIDUAL GAS IONIZATION BEAM PROFILE MONITOR ON 40MeV H— BEAM TRANSPORT LINE

    Institute of Scientific and Technical Information of China (English)

    徐伟鹏; E.Takasaki

    1995-01-01

    The monitor is composed of a pair of electrodes,a single stage of microchannel plate,a phosphor screen,a CCD camera and a PC computer,To obtain a good uniform collecting field,forming electrodes system is used instead of that with a resistive divider,The readout system is performed by the phosphor screen and the CCD camera because the spatial resolution is not limited by the mechanical structure like the anode strip type and such video display system is very useful for beam studies and operation of the 40MeV linac,Besides,the design and test results are described in detail.

  13. Achieving Stability Requirements for Nanoprobe and Long Beam Lines at NSLS II. A Comprehensive Study

    Energy Technology Data Exchange (ETDEWEB)

    Simos,N.; Fallier, M.; Hill, J.; Berman, L.; Evans-Lutterodt, K.; Broadbent, A.

    2008-06-23

    Driven by beam stability requirements at the NSLS II synchrotron, such that the desired small beam sizes and high brightness are both realized and stable, a comprehensive study has been launched seeking to provide assurances that stability at the nanometer level at critical x-ray beam-lines, is achievable, given the natural and cultural vibration environment at the selected site. The study consists of (a) an extensive investigation of the site to evaluate the existing ground vibration, in terms of amplitude, frequency content and coherence, and (b) of a numerical study of wave propagation and interaction with the infrastructure of the sensitive lines. The paper presents results from both aspects of the study.

  14. In situ baking method for degassing of a kicker magnet in accelerator beam line

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Junichiro, E-mail: kamiya.junichiro@jaea.go.jp; Ogiwara, Norio; Yanagibashi, Toru; Kinsho, Michikazu [Japan Atomic Energy Agency, J-PARC Center, Ooaza Shirakata 2-4, Tokai, Naka, Ibaraki 319-1195 (Japan); Yasuda, Yuichi [SAKAGUCHI E.H VOC CORP., Sakura Dai-san Kogyodanchi 1-8-6, Osaku, Sakura, Chiba 285-0802 (Japan)

    2016-03-15

    In this study, the authors propose a new in situ degassing method by which only kicker magnets in the accelerator beam line are baked out without raising the temperature of the vacuum chamber to prevent unwanted thermal expansion of the chamber. By simply installing the heater and thermal radiation shield plates between the kicker magnet and the chamber wall, most of the heat flux from the heater directs toward the kicker magnet. The result of the verification test showed that each part of the kicker magnet was heated to above the target temperature with a small rise in the vacuum chamber temperature. A graphite heater was selected in this application to bake-out the kicker magnet in the beam line to ensure reliability and easy maintainability of the heater. The vacuum characteristics of graphite were suitable for heater operation in the beam line. A preliminary heat-up test conducted in the accelerator beam line also showed that each part of the kicker magnet was successfully heated and that thermal expansion of the chamber was negligibly small.

  15. Design of a support system for the vertical beam transfer lines of the ELENA project

    CERN Document Server

    Bozhkov, Kristiyan

    2016-01-01

    This report aims to present the design of a support system for the vertical beam transfer lines of the ELENA project. Two different designs can be found in this report. The mechanical strength and the structure performance of the support are analysed by a finite element model.

  16. Beam line I411 at MAX II--performance and first results

    CERN Document Server

    Baessler, M; Jurvansuu, M; Feifel, R; Forsell, J O; Tarso-Fonseca, P D; Kivimaeki, A; Sundin, S; Sorensen, S L; Nyholm, R; Bjoerneholm, O; Aksela, S; Svensson, S

    2001-01-01

    We report on the characteristics and first results from the soft X-ray beam line I411, based on an undulator at the third generation synchrotron facility MAX II, Sweden. The beam line is designed for high-resolution, angle-resolved electron spectroscopy on gases, liquids and solids. Main components are the modified SX700 monochromator and the end station, both of which were previously used at beam line 51 at MAX I. The end station is equipped with a rotatable SES-200 hemispherical electron-analyser. Before the end station, a one-metre section is reserved for exchangeable experimental set-ups. The usable photon energy range is 50-1500 eV and the photon flux is two orders of magnitudes higher compared to beam line 51. At 400 eV a resolving power of about 5700 in the first order of the monochromator grating could be obtained. In gas phase, a total electron energy resolution of 16 meV has been achieved. Detailed results on the undulator performance, flux, photon and electron energy resolution as well as some tech...

  17. The Fluka Linebuilder and Element Database: Tools for Building Complex Models of Accelerators Beam Lines

    CERN Document Server

    Mereghetti, A; Cerutti, F; Versaci, R; Vlachoudis, V

    2012-01-01

    Extended FLUKA models of accelerator beam lines can be extremely complex: heavy to manipulate, poorly versatile and prone to mismatched positioning. We developed a framework capable of creating the FLUKA model of an arbitrary portion of a given accelerator, starting from the optics configuration and a few other information provided by the user. The framework includes a builder (LineBuilder), an element database and a series of configuration and analysis scripts. The LineBuilder is a Python program aimed at dynamically assembling complex FLUKA models of accelerator beam lines: positions, magnetic fields and scorings are automatically set up, and geometry details such as apertures of collimators, tilting and misalignment of elements, beam pipes and tunnel geometries can be entered at user’s will. The element database (FEDB) is a collection of detailed FLUKA geometry models of machine elements. This framework has been widely used for recent LHC and SPS beam-machine interaction studies at CERN, and led to a dra...

  18. Results from Tests of the Muon Endcap Alignment System in the H8 Beam Line 2002

    CERN Document Server

    Amelung, C; Cerutti, F; Handrich, K; Hashemi, K S; Mair, K; Palestini, S; Rothberg, J E; Schricker, A; Trigger, I

    2003-01-01

    The ATLAS muon spectrometer endcap test setup assembled in the H8 beam line at CERN in 2002 consisted of six alignment bars and six MDT chambers, representing part of one octant of the endcap. These elements were equipped with a full set of alignment sensors, which were used to obtain a first appraisal of the performance of the alignment system.

  19. On-line beam monitoring for neutron capture therapy at the MIT Research Reactor

    Science.gov (United States)

    Harling, Otto K.; Moulin, Damien J.; Chabeuf, Jean-Michel; Solares, Guido R.

    1995-08-01

    Neutron capture therapy sets new requirements on the measurement and monitoring of the radiation fields used in this new form of therapy. Beams used for neutron capture therapy are comprised of mixed radiation fields which include slow, epithermal, and fast neutrons, as well as gamma rays. A computer-based beam monitoring system for epithermal or thermal neutron capture therapy is described. This system provides accurate, sensitive, and rapid on-line readout and recording of the various beam components. Readout of fluxes, fluences, and corresponding doses in the target are provided in color coded graphic analog as well as numerical form on the computer monitors. Variations in neutron spectrum or spatial distribution of the beam can be rapidly diagnosed with the aid of the monitor readout. Redundancy of fluence measurement is provided by an independent system using scalers and timers and by utilizing reactor power measuring instruments.

  20. Design of a large acceptance, high efficiency energy selection system for the ELIMAIA beam-line

    Science.gov (United States)

    Schillaci, F.; Maggiore, M.; Andó, L.; Cirrone, G. A. P.; Cuttone, G.; Romano, F.; Scuderi, V.; Allegra, L.; Amato, A.; Gallo, G.; Korn, G.; Leanza, R.; Margarone, D.; Milluzzo, G.; Petringa, G.

    2016-08-01

    A magnetic chicane based on four electromagnetic dipoles is going to be realized by INFN-LNS to be used as an Energy Selection System (ESS) for laser driven proton beams up to 300 MeV and C6+ up to 70 MeV/u. The system will provide, as output, ion beams with a contrallable energy spread varying from 5% up to 20% according to the aperture slit size. Moreover, it has a very wide acceptance in order to ensure a very high transmission efficiency and, in principle, it has been designed to be used also as an active energy modulator. This system is the core element of the ELIMED (ELI-Beamlines MEDical and Multidisciplinary applications) beam transport, dosimetry and irradiation line that will be developed by INFN-LNS (It) and installed at the ELI-Beamlines facility in Prague (Cz). ELIMED will be the first user's open transport beam-line where a controlled laser-driven ion beam will be used for multidisciplinary research. The definition of well specified characteristics, both in terms of performance and field quality, of the magnetic chicane is crucial for the system realization, for the accurate study of the beam dynamics and for the proper matching with the Permanent Magnet Quadrupoles (PMQs) used as a collection system already designed. Here, the design of the magnetic chicane is described in details together with the adopted solutions in order to realize a robust system form the magnetic point of view. Moreover, the first preliminary transport simulations are also described showing the good performance of the whole beam line (PMQs+ESS).

  1. Beam emittance measurements and simulations of injector line for radio frequency quadrupole

    Science.gov (United States)

    Mathew, Jose V.; Rao, S. V. L. S.; Pande, Rajni; Singh, P.

    2015-07-01

    A 400 keV deuteron (D+) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H+ and D+ beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D+ beam through the RFQ, while 95% transmission has been measured experimentally.

  2. Modeling the Biophysical Effects in a Carbon Beam Delivery Line using Monte Carlo Simulation

    CERN Document Server

    Cho, Ilsung; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-01-01

    Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion beam therapy. In this study the biological effectiveness of a carbon ion beam delivery system was investigated using Monte Carlo simulation. A carbon ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon beam transporting into media. An incident energy carbon ion beam in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model is applied to describe the RBE of 10% survival in human salivary gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetrating depth of the water phantom along the incident beam direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the water phantom depth.

  3. Modeling the biophysical effects in a carbon beam delivery line by using Monte Carlo simulations

    Science.gov (United States)

    Cho, Ilsung; Yoo, SeungHoon; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-09-01

    The Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion-beam therapy. In this study, the biological effectiveness of a carbon-ion beam delivery system was investigated using Monte Carlo simulations. A carbon-ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon-ion beam transport into media. An incident energy carbon-ion beam with energy in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model was applied to describe the RBE of 10% survival in human salivary-gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetration depth in the water phantom along the incident beam's direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE-weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the depth in the water phantom.

  4. Beam imaging in the injection line of the INFN-LNS superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Nicolosi, Dario, E-mail: dario.nicolosi@lns.infn.it; Cosentino, Luigi; Mascali, David; Pappalardo, Alfio; Castro, Maurizio; Celona, Luigi; Marchetta, Carmelo; Marletta, Salvatore; Maugeri, Antonio; Rifuggiato, Danilo; Seminara, Angelo; Gammino, Santo [INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy)

    2016-02-15

    A cheap and efficient diagnostic system for beam monitoring has been recently developed at INFN-LNS in Catania. It consists of a high sensitivity CCD camera detecting the light produced by an ion beam hitting the surface of a scintillating screen and a frame grabber for image acquisition. A scintillating screen, developed at INFN-LNS and consisting of a 2 μm BaF{sub 2} layer evaporated on an aluminium plate, has been tested by using {sup 20}Ne and {sup 40}Ar beams in the keV energy range. The CAESAR ECR ion source has been used for investigating the influence of the frequency and magnetic field tuning effects, the impact of the microwave injected power, and of the focusing solenoids along the low energy beam transport on the beam shape and current. These tests will allow to better understand the interplay between the plasma and beam dynamics and, moreover, to improve the transport efficiency along the low energy beam line and the matching with the superconducting cyclotron, particularly relevant in view of the expected upgrade of the machine.

  5. Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fink, D. A.; Lettry, J.; Scrivens, R.; Steyaert, D. [CERN, 1211 Geneva 23 (Switzerland); Midttun, Ø. [University of Oslo, P.O. Box 1048, 0316 Oslo (Norway); CERN, 1211 Geneva 23 (Switzerland); Valerio-Lizarraga, C. A. [Departamento de Investigación en Fisica, Universidad de Sonora, Hermosillo (Mexico); CERN, 1211 Geneva 23 (Switzerland)

    2015-04-08

    The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

  6. Optimization of the beam extraction systems for the Linac4 H- ion source

    Science.gov (United States)

    Fink, D. A.; Lettry, J.; Midttun, Ø.; Scrivens, R.; Steyaert, D.; Valerio-Lizarraga, C. A.

    2015-04-01

    The development of the Linac 4 and its integration into CERN's acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H- beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H- beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm. mrad. The previously installed beam extraction system has been designed for an H- ion beam intensity of 20 mA produced by an RF-volume source with an electron to H- ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H- ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H- source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

  7. Study of transverse beam splitting for multi-turn extraction for the CERN PS2 ring

    CERN Document Server

    Giovannozzi, Massimo; CERN. Geneva. ATS Department

    2011-01-01

    In this paper a layout for the elements needed to split transversely the beam for a multi-turn extraction system in the PS2 ring is proposed and discussed. Additional sextupoles and octupoles are installed in one of the straight sections to generate the stable islands in the horizontal phase space. Scans over various beam dynamics quantities were performed to provide hints for an optimisation of the scheme. The results are presented and discussed in details.

  8. MICRO-BUNCHING OF THE AGS SLOW EXTRACTED BEAM FOR A RARE KAON DECAY SEARCH.

    Energy Technology Data Exchange (ETDEWEB)

    GLENN,J.; SIVERTZ,M.; CHIANG,I.; LAZARUS,D.; KOSCIELNIAK,S.

    2001-06-18

    The AGS Slow Extracted Beam (SEB) must be chopped with 250 ps bursts every 40 ns to permit time-of-flight (ToF) measurement of the secondary K{sup 0} beam. Standard techniques to produce this level of bunching would require excessive rf voltage, thus we have developed a ''Micro-Bunching'' technique of extracting the beam as it is forced between empty rf buckets. A specification of the required rf system will be given. Four-dimensional model simulations of particle dynamics for the planned rf and extraction systems will be shown. Simulations of previous tests along with the test measurements are also presented. Measurement of tight bunching requires dedicated instrumentation. The design of a detector system to measure bunch widths and the extinction factor between bunches will be given; considerations include the various particles produced and transported, timing precision and background.

  9. Optimization of cold neutron beam extraction at ESS

    DEFF Research Database (Denmark)

    Schönfeldt, Troels; Batkov, K.; Klinkby, Esben Bryndt

    The present study takes its origin in the baseline design of European Spallation Source where a cold and a thermal moderator are situated next to each other enabling bispectral extraction. The study aims at mapping the differences in various neutron distributions depending on the angle and position...... from which the moderator is viewed. This study does not only show changes in both cold and thermal neutron flux, depending on extraction position, but also shows that there are significant differences in the wavelength spectrum and origin of neutrons depending on the angel of view....

  10. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W. P.; Assmann, R.; Decker, F.-J.; Hogan, M. J.; Iverson, R.; Siemann, R. H.; Walz, D. (and others)

    2001-10-01

    Emissions produced or initiated by a 30-GeV electron beam propagating through a {approx}1-m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  11. Measurements of Radiation Near An Atomic Spectral Line From the Interaction of a 30-GeV Electron Beam And a Long Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W.P.; /LBL, Berkeley; Assmann, R.; Decker, F.J.; Hogan, M.J.; Iverson, R.; Siemann, R.H.; Walz, D.; Whittum, D.; /SLAC; Blue, B.; Clayton, C.; Joshi, C.; Marsh, K.A.; Mori, W.B.; Wang, S.; /UCLA; Katsouleas, T.; Lee, S.; Muggli, P.; /Southern California U.

    2005-09-12

    Emissions produced or initiated by a 30 GeV electron beam propagating through a {approx}1 m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma; estimates of plasma and neutral density have been extracted. Increases in visible background radiation consistent with increased plasma recombination emissions due to dissipation of wakefields were simultaneously measured.

  12. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Energy Technology Data Exchange (ETDEWEB)

    Catravas, P.E.; Chattopadhyay, S.; Esarey, E.; Leemans, W.P.; Assmann, R.; Decker, F.-J.; Hogan, M.J.; Iverson, R.; Siemann, R.H.; Walz, D.; Whittum, D.; Blue, B.; Clayton, C; Joshi, C.; Marsh, K.A.; Mori, W.B.; Wang, S.; Katsouleas, T.; Lee, S.; Muggli, P.

    2000-10-31

    Emissions produced or initiated by a 30 GeV electron beam propagating through a {approx} 1 m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creating of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  13. Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma

    Science.gov (United States)

    Catravas, P.; Chattopadhyay, S.; Esarey, E.; Leemans, W. P.; Assmann, R.; Decker, F.-J.; Hogan, M. J.; Iverson, R.; Siemann, R. H.; Walz, D.; Whittum, D.; Blue, B.; Clayton, C.; Joshi, C.; Marsh, K. A.; Mori, W. B.; Wang, S.; Katsouleas, T.; Lee, S.; Muggli, P.

    2001-10-01

    Emissions produced or initiated by a 30-GeV electron beam propagating through a ~1-m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

  14. Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M. J.; Boilson, D.; Hemsworth, R. S.; Geli, F.; Graceffa, J.; Urbani, M.; Schunke, B.; Chareyre, J. [ITER Organisation, 13607 St. Paul-Lez-Durance Cedex (France); Dlougach, E.; Krylov, A. [RRC Kurchatov institute, 1, Kurchatov Sq, Moscow, 123182 (Russian Federation)

    2015-04-08

    The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER

  15. Line end shortening and application of novel correction algorithms in e-beam direct write

    Science.gov (United States)

    Freitag, Martin; Choi, Kang-Hoon; Gutsch, Manuela; Hohle, Christoph

    2011-03-01

    For the manufacturing of semiconductor technologies following the ITRS roadmap, we will face the nodes well below 32nm half pitch in the next 2~3 years. Despite being able to achieve the required resolution, which is now possible with electron beam direct write variable shaped beam (EBDW VSB) equipment and resists, it becomes critical to precisely reproduce dense line space patterns onto a wafer. This exposed pattern must meet the targets from the layout in both dimensions (horizontally and vertically). For instance, the end of a line must be printed in its entire length to allow a later placed contact to be able to land on it. Up to now, the control of printed patterns such as line ends is achieved by a proximity effect correction (PEC) which is mostly based on a dose modulation. This investigation of the line end shortening (LES) includes multiple novel approaches, also containing an additional geometrical correction, to push the limits of the available data preparation algorithms and the measurement. The designed LES test patterns, which aim to characterize the status of LES in a quick and easy way, were exposed and measured at Fraunhofer Center Nanoelectronic Technologies (CNT) using its state of the art electron beam direct writer and CD-SEM. Simulation and exposure results with the novel LES correction algorithms applied to the test pattern and a large production like pattern in the range of our target CDs in dense line space features smaller than 40nm will be shown.

  16. High efficiency energy extraction from a relativistic electron beam in a strongly tapered undulator

    CERN Document Server

    Sudar, Nicholas; Duris, Joe; Gadjev, Ivan; Polyaniy, Mikhail; Pogorelsky, Igor; Fedurin, Mikhail; Swinson, Christina; Babzien, Marcus; Kusche, Karl; Gover, Avi

    2016-01-01

    We present results of an experiment where, using a 200 GW CO2 laser seed, a 65 MeV electron beam was decelerated down to 35 MeV in a 54 cm long strongly tapered helical magnetic undulator, extracting over 30$\\%$ of the initial electron beam energy to coherent radiation. These results demonstrate unparalleled electro-optical conversion efficiencies for a relativistic beam in an undulator field and represent an important step in the development of high peak and average power coherent radiation sources.

  17. High Efficiency Energy Extraction from a Relativistic Electron Beam in a Strongly Tapered Undulator

    Science.gov (United States)

    Sudar, N.; Musumeci, P.; Duris, J.; Gadjev, I.; Polyanskiy, M.; Pogorelsky, I.; Fedurin, M.; Swinson, C.; Kusche, K.; Babzien, M.; Gover, A.

    2016-10-01

    We present results of an experiment where, using a 200 GW CO2 laser seed, a 65 MeV electron beam was decelerated down to 35 MeV in a 54-cm-long strongly tapered helical magnetic undulator, extracting over 30% of the initial electron beam energy to coherent radiation. These results, supported by simulations of the radiation field evolution, demonstrate unparalleled electro-optical conversion efficiencies for a relativistic beam in an undulator field and represent an important step in the development of high peak and average power coherent radiation sources.

  18. Extraction of Urban Power Lines from Vehicle-Borne LiDAR Data

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2014-04-01

    Full Text Available Airborne LiDAR has been traditionally used for power line cruising. Nevertheless, data acquisition with airborne LiDAR is constrained by the complex environments in urban areas as well as the multiple parallel line structures on the same power line tower, which means it is not directly applicable to the extraction of urban power lines. Vehicle-borne LiDAR system has its advantages upon airborne LiDAR and this paper tries to utilize vehicle-borne LiDAR data for the extraction of urban power lines. First, power line points are extracted using a voxel-based hierarchical method in which geometric features of each voxel are calculated. Then, a bottom-up method for filtering the power lines belonging to each power line is proposed. The initial clustering and clustering recovery procedures are conducted iteratively to identify each power line. The final experiment demonstrates the high precision of this technique.

  19. Fast beam cut-off method in RF-knockout extraction for spot-scanning

    Science.gov (United States)

    Furukawa, Takuji; Noda, Koji

    2002-08-01

    An irradiation method with magnetic scanning has been developed in order to provide accurate irradiation even for an irregular target shape. The scanning method has strongly required a lower ripple of the beam spill and a faster response to beam-on/off in slow extraction from a synchrotron ring. At HIMAC, RF-knockout extraction has utilized a bunched beam to reduce the beam-spill ripple. Therefore, particles near the resonance can be spilled out from the separatrices by synchrotron oscillation as well as by a transverse RF field. From this point of view, a fast beam cut-off method has been proposed and verified by both simulations and experiments. The maximum delay from the beam cut-off signal to beam-off has been improved to around 60 μs from 700 μs by a usual method. Unwanted dose has been considerably reduced by around a factor of 10 compared with that by the usual method.

  20. A feasibility study of H sup - beam extraction technique using YAG laser

    CERN Document Server

    Meigo, S I; Hasegawa, K; Ikeda, Y; Nakagawa, S; Oigawa, H

    2002-01-01

    Under a framework of JAERI-KEK joint project of high intensity proton accelerator, as for research and develop of the accelerator driven nuclear transmutation of the long lived radioactive nuclide, it is planed to built the Transmutation Physics Experiment Facility (TEF-P) and the Transmutation Engineering Experiment Facility (TEF-E). The TEF-P is used for the experiments for subcritical system coupled with a spallation neutron target bombarded with 600-MeV proton beam accelerated by the LINAC. To limit the maximum thermal power less than 500 W at the TEF-P, an incident beam power should be less than 10 W. On the contrary, at the TEF-E, high power beam of 200 kW is requested. Both high and low power beams are demanded for the transmutation facilities. It is difficult to deliver a low power beam to the TEF-P. Conventional beam extraction technique with a thin foil, is not desirable because the scattering of the beam at the foil requires the massive shield. Therefore, we study a new technique to extract a small...

  1. On the energy dependence of proton beam extraction with a bent crystal

    Science.gov (United States)

    Arduini, G.; Elsener, K.; Fidecaro, G.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E.

    1998-03-01

    Proton beam extraction from the CERN SPS by means of a bent silicon crystal is reported at three different energies, 14 GeV, 120 GeV and 270 GeV. The experimental results are compared to computer simulations which contain a sound model of the SPS accelerator as well as the channeling phenomena in bent crystals. The overall energy dependence of crystal assisted proton beam extraction is understood and provides the basis to discuss such a scheme for future accelerators. © 1998

  2. A beam monitoring and validation system for continuous line scanning in proton therapy

    Science.gov (United States)

    Klimpki, G.; Psoroulas, S.; Bula, C.; Rechsteiner, U.; Eichin, M.; Weber, D. C.; Lomax, A.; Meer, D.

    2017-08-01

    Line scanning represents a faster and potentially more flexible form of pencil beam scanning than conventional step-and-shoot irradiations. It seeks to minimize dead times in beam delivery whilst preserving the possibility of modulating the dose at any point in the target volume. Our second generation proton gantry features irradiations in line scanning mode, but it still lacks a dedicated monitoring and validation system that guarantees patient safety throughout the irradiation. We report on its design and implementation in this paper. In line scanning, we steer the proton beam continuously along straight lines while adapting the speed and/or current frequently to modulate the delivered dose. We intend to prevent delivery errors that could be clinically relevant through a two-stage system: safety level 1 monitors the beam current and position every 10 μs. We demonstrate that direct readings from ionization chambers in the gantry nozzle and Hall probes in the scanner magnets provide required information on current and position, respectively. Interlocks will be raised when measured signals exceed their predefined tolerance bands. Even in case of an erroneous delivery, safety level 1 restricts hot and cold spots of the physically delivered fraction dose to  ±36~mGy (±2% of 2~Gy biologically). In safety level 2—an additional, partly redundant validation step—we compare the integral line profile measured with a strip monitor in the nozzle to a forward-calculated prediction. The comparison is performed between two line applications to detect amplifying inaccuracies in speed and current modulation. This level can be regarded as an online quality assurance of the machine. Both safety levels use devices and functionalities already installed along the beamline. Hence, the presented monitoring and validation system preserves full compatibility of discrete and continuous delivery mode on a single gantry, with the possibility of switching between modes during the

  3. Design method for a laser line beam shaper of a general 1D angular power distribution

    Science.gov (United States)

    Oved, E.; Oved, A.

    2016-05-01

    Laser line is a beam of laser, spanned in one direction using a beam shaper to form a fan of light. This illumination tool is important in laser aided machine vision, 3D scanners, and remote sensing. For some applications the laser line should have a specific angular power distribution. If the distribution is nonsymmetrical, the beam shaper is required to be nonsymmetrical freeform, and its design process using optical design software is time consuming due to the long optimization process which usually converges to some local minimum. In this paper we introduce a new design method of a single element refractive beam shaper of any predefined general 1D angular power distribution. The method makes use of a notion of "prism space", a geometrical representation of all double refraction prisms, and any 1D beam shaper can be described by a continuous curve in this space. It is shown that infinitely many different designs are possible for any given power distribution, and it is explained how an optimal design is selected among them, based on criteria such as high transmission, low surface slopes, robustness to manufacturing errors etc. The method is non-parametric and hence does not require initial guess of a functional form, and the resultant optical surfaces are described by a sequence of points, rather than by an analytic function.

  4. Uniform H(-) ion beam extraction in a large negative ion source with a tent-shaped magnetic filter.

    Science.gov (United States)

    Tobari, H; Hanada, M; Kashiwagi, M; Taniguchi, M; Umeda, N; Watanabe, K; Inoue, T; Sakamoto, K; Takado, N

    2008-02-01

    Based on previous studies on the spatial uniformity of the negative ion beam, the external magnetic filter was replaced to a novel tent-shaped magnetic filter in the JAEA 10 A negative ion source. The line-cusp field configuration on the source chamber was also changed to form a symmetric magnetic field like many of positive ion sources aiming at high proton yield. This magnetic field configuration allows fast electrons emitted from filament cathodes to rotate azimuthally inside the source chamber. The source configuration thus prevents localization of fast electrons due to their B x grad B drift in the filter field. As a result, the H(-) ion beam profile extracted from a wide region of 340 x 170 mm(2) showed reduction of standard deviation from 16% in the original to 7.9% with the tent filter. The negative ion source with the tent filter satisfied the requirement of the beam uniformity for a large negative ion source in the ITER neutral beam injection.

  5. Slow beam-extraction method using a fast Q-magnet assisted by RF-knockout

    Science.gov (United States)

    Nakanishi, Tetsuya; Furukawa, Takuji; Yoshida, Katsuhisa; Noda, Koji

    2005-11-01

    A new method for slow beam-extraction from a synchrotron ring is proposed, based on controlling a quadrupole field with a fast response (FQ), assisted by a transverse RF-field (RF-knockout). This method works as follows: (1) particles of a circulating beam are diffused by RF-knockout to just inside the boundary of a separatrix produced under a resonant condition, (2) exciting the FQ shrinks the separatrix to a certain size, and the particles outside the separatrix can be extracted, (3) the fast Q-field is turned off, and (4) the above process is repeated until all of the circulating beam is completely extracted. This method can extract prescribed particles at required timings quickly and precisely, because it is controlled with only the fast Q-field. A proof-of-principle experiment was carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) synchrotron. As a result, it was verified that the beam was extracted only with exciting the FQ, but not with turning the RF-knockout on.

  6. In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

    Science.gov (United States)

    Shao, Yiping; Sun, Xishan; Lou, Kai; Zhu, Xiaorong R.; Mirkovic, Dragon; Poenisch, Falk; Grosshans, David

    2014-07-01

    We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered ˜50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180° were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A 22Na disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.

  7. Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator.

    Science.gov (United States)

    Kalvas, T; Welton, R F; Tarvainen, O; Han, B X; Stockli, M P

    2012-02-01

    A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H(-) ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H(-) currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  8. Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulatora)

    Science.gov (United States)

    Kalvas, T.; Welton, R. F.; Tarvainen, O.; Han, B. X.; Stockli, M. P.

    2012-02-01

    A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H- ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H- currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  9. Design and performance of the beam transfer lines for the HIE-ISOLDE Project

    CERN Document Server

    Parfenova, A; Bauche, J; Cantero, E D; Farantatos, P; Fraser, M A; Goddard, B; Kadi, Y; Kolehmainen, A J; Lanaia, D; Martino, M; Mompo, R; Siesling, E; Sosa, A G; Timmins, M; Vandoni, G; Voulot, D; Zografos, E

    2013-01-01

    Beam design and beam optics studies for the HIE-ISOLDE transfer lines [1] have been carried out in MadX [2], and benchmarked against Trace3D results [3, 4]. Magnet field errors and alignment imperfections leading to deviations from design parameters have been treated explicitly, and the sensitivity of the machine lattice to different individual error sources was studied. As a result, the tolerances for the various error-contributions have been specified for the different equipment systems. The design choices for the expected magnet field and power supply quality, alignment tolerances, instrument resolution and physical aperture were validated. The methodology and results of the studies are presented.

  10. Mechanical Design of a Heavy Ion Beam Dump for the RIA Fragmentation Line

    CERN Document Server

    Stein, Werner; Conner, David L

    2005-01-01

    The RIA fragmentation line requires a beam stop for the primary beam downstream of the first dipole magnet. The beam may consist of U, Ca, Sn, Kr, or O ions. with a variety of power densities. The configuration with highest power density is for the U beam, with a spot size of 3 cm x 3 cm and a total power of up to 300 kW. The mechanical design of the dump that meets these criteria consists of a 50 cm diameter aluminum wheel with water coolant channels. A hollow drive shaft supplies the coolant water and connects the wheel to an electrical motor located in an air space in the floor above the dump. The beam strikes the wheel along the outer perimeter and passes through a thin window of aluminum where 10% of its power is absorbed and the remainder of the beam is absorbed in flowing water behind the window. Rotation of the wheel at 400 RPM results in maximum aluminum temperatures below 100 C and acceptably low thermal stresses of 5 ksi. Rotating the wheel also results in low radiation damage levels by spreading t...

  11. Reducing the extraction loss via laser notching the H- beam at the Booster injection revolution frequency

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xi; Ankenbrandt, Charles M.; /Fermilab

    2005-05-01

    With the requirement for more protons per hour from Booster, the radiation is a limiting factor. Laser notching the H{sup -} beam at the Booster injection revolution frequency and properly aligning those notches on top of each other at the injection and relative to the trigger of firing extraction kickers can remove most of the extraction loss caused by the slow rise time of the kicker field.

  12. A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line.

    Science.gov (United States)

    Romano, F; Cirrone, G A P; Cuttone, G; Rosa, F Di; Mazzaglia, S E; Petrovic, I; Fira, A Ristic; Varisano, A

    2014-06-21

    Fluence, depth absorbed dose and linear energy transfer (LET) distributions of proton and carbon ion beams have been investigated using the Monte Carlo code Geant4 (GEometry ANd Tracking). An open source application was developed with the aim to simulate two typical transport beam lines, one used for ocular therapy and cell irradiations with protons and the other for cell irradiations with carbon ions. This tool allows evaluation of the primary and total dose averaged LET and predict their spatial distribution in voxelized or sliced geometries. In order to reproduce the LET distributions in a realistic way, and also the secondary particles' contributions due to nuclear interactions were considered in the computations. Pristine and spread-out Bragg peaks were taken into account both for proton and carbon ion beams, with the maximum energy of 62 MeV/n. Depth dose distributions were compared with experimental data, showing good agreement. Primary and total LET distributions were analysed in order to study the influence of contributions of secondary particles in regions at different depths. A non-negligible influence of high-LET components was found in the entrance channel for proton beams, determining the total dose averaged LET by the factor 3 higher than the primary one. A completely different situation was obtained for carbon ions. In this case, secondary particles mainly contributed in the tail that is after the peak. The results showed how the weight of light and heavy secondary ions can considerably influence the computation of LET depth distributions. This has an important role in the interpretation of results coming from radiobiological experiments and, therefore, in hadron treatment planning procedures.

  13. A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line

    Science.gov (United States)

    Romano, F.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Mazzaglia, S. E.; Petrovic, I.; Ristic Fira, A.; Varisano, A.

    2014-06-01

    Fluence, depth absorbed dose and linear energy transfer (LET) distributions of proton and carbon ion beams have been investigated using the Monte Carlo code Geant4 (GEometry ANd Tracking). An open source application was developed with the aim to simulate two typical transport beam lines, one used for ocular therapy and cell irradiations with protons and the other for cell irradiations with carbon ions. This tool allows evaluation of the primary and total dose averaged LET and predict their spatial distribution in voxelized or sliced geometries. In order to reproduce the LET distributions in a realistic way, and also the secondary particles’ contributions due to nuclear interactions were considered in the computations. Pristine and spread-out Bragg peaks were taken into account both for proton and carbon ion beams, with the maximum energy of 62 MeV/n. Depth dose distributions were compared with experimental data, showing good agreement. Primary and total LET distributions were analysed in order to study the influence of contributions of secondary particles in regions at different depths. A non-negligible influence of high-LET components was found in the entrance channel for proton beams, determining the total dose averaged LET by the factor 3 higher than the primary one. A completely different situation was obtained for carbon ions. In this case, secondary particles mainly contributed in the tail that is after the peak. The results showed how the weight of light and heavy secondary ions can considerably influence the computation of LET depth distributions. This has an important role in the interpretation of results coming from radiobiological experiments and, therefore, in hadron treatment planning procedures.

  14. Millimeter-wave Line Ratios and Sub-beam Volume Density Distributions

    Science.gov (United States)

    Leroy, Adam K.; Usero, Antonio; Schruba, Andreas; Bigiel, Frank; Kruijssen, J. M. Diederik; Kepley, Amanda; Blanc, Guillermo A.; Bolatto, Alberto D.; Cormier, Diane; Gallagher, Molly; Hughes, Annie; Jiménez-Donaire, Maria J.; Rosolowsky, Erik; Schinnerer, Eva

    2017-02-01

    We explore the use of mm-wave emission line ratios to trace molecular gas density when observations integrate over a wide range of volume densities within a single telescope beam. For observations targeting external galaxies, this case is unavoidable. Using a framework similar to that of Krumholz & Thompson, we model emission for a set of common extragalactic lines from lognormal and power law density distributions. We consider the median density of gas that produces emission and the ability to predict density variations from observed line ratios. We emphasize line ratio variations because these do not require us to know the absolute abundance of our tracers. Patterns of line ratio variations have the potential to illuminate the high-end shape of the density distribution, and to capture changes in the dense gas fraction and median volume density. Our results with and without a high-density power law tail differ appreciably; we highlight better knowledge of the probability density function (PDF) shape as an important area. We also show the implications of sub-beam density distributions for isotopologue studies targeting dense gas tracers. Differential excitation often implies a significant correction to the naive case. We provide tabulated versions of many of our results, which can be used to interpret changes in mm-wave line ratios in terms of adjustments to the underlying density distributions.

  15. Off-line production of a sup 7 Be radioactive ion beam

    CERN Document Server

    Gialanella, L; De Cesare, N; D'Onofrio, A; Romano, M; Campajola, L; Formicola, A; Fülöp, Z; Gyürky, G; Imbriani, G; Lubritto, C; Ordine, A; Roca, V; Rogalla, D; Rolfs, C; Russo, M; Sabbarese, C; Somorjai, E; Strieder, F; Terrasi, F; Trautvetter, H P

    2002-01-01

    A sup 7 Be ion beam of several particle pA at 8 MeV has been produced at the TTT3 tandem of the University 'Federico II' in Naples. The sup 7 Be nuclides were formed via the sup 7 Li(p,n) sup 7 Be reaction using a metallic Li target and an 11.4 MeV proton beam of 20 mu A intensity, delivered by the cyclotron in Debrecen. Methods of hot chemistry were used to extract the sup 7 Be nuclides from the Li matrix and to prepare the sup 7 Be cathodes for the ion sputter source of the tandem. Examples of sup 7 Be beam applications are given.

  16. Identification of dental root canals and their medial line from micro-CT and cone-beam CT records

    Directory of Open Access Journals (Sweden)

    Benyó Balázs

    2012-10-01

    Full Text Available Abstract Background Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenges. Accurate shape information of the root canals may also be used by manufacturers of endodontic instruments in order to make more efficient clinical tools. Method Novel image processing procedures dedicated to the automated detection of the medial axis of the root canal from dental micro-CT and cone-beam CT records are developed. For micro-CT, the 3D model of the root canal is built up from several hundred parallel cross sections, using image enhancement, histogram based fuzzy c-means clustering, center point detection in the segmented slice, three dimensional inner surface reconstruction, and potential field driven curve skeleton extraction in three dimensions. Cone-beam CT records are processed with image enhancement filters and fuzzy chain based regional segmentation, followed by the reconstruction of the root canal surface and detecting its skeleton via a mesh contraction algorithm. Results The proposed medial line identification and root canal detection algorithms are validated on clinical data sets. 25 micro-CT and 36 cone-beam-CT records are used in the validation procedure. The overall success rate of the automatic dental root canal identification was about 92% in both procedures. The algorithms proved to be accurate enough for endodontic therapy planning. Conclusions Accurate medial line identification and shape detection algorithms of dental root canal have been developed. Different procedures are defined for micro-CT and cone-beam CT records. The automated execution of the subsequent processing steps allows easy application of the algorithms in the dental care. The output data of the image processing procedures

  17. Bunching of an Intense Electron-Beam Extracted from a Triode Gun Modulated at 1 Ghz

    NARCIS (Netherlands)

    van der Geer, C. A. J.; Bakker, R. J.; van der Meer, A. F. G.; van Amersfoort, P. W.; Gillespie, W. A.; Saxon, G.

    1991-01-01

    We present measurements of the bunch length and emittance of a high-current electron beam, which is extracted from a triode modulated at 1 GHz and subsequently compressed by means of velocity modulation in a prebuncher cavity. The prebuncher is detuned by about 1 MHz in order to ensure that the tota

  18. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure ...

  19. Extension of Pierce model to multiple transmission lines interacting with an electron beam

    CERN Document Server

    Tamma, Venkata Ananth

    2013-01-01

    A possible route towards achieving high power microwave devices is through the use of novel slow-wave structures employing multiple coupled transmission lines (MTLs) whose behavior when coupled to electron beams have not been sufficiently explored. We present the extension of the one-dimensional linearized Pierce theory to MTLs coupled to a single electron beam. We develop multiple formalisms to calculate the k-{\\omega} dispersion relation of the system and find that the existence of a growing wave solution is always guaranteed if the electron propagation constant is larger than or equal to the largest propagation constant of the MTL system. We verify our findings with illustrative examples which bring to light unique properties of the system in which growing waves were found to exist within finite bands of the electron propagation constant and discuss possible approach to improve the gain. By treating the beam-MTL interaction as distributed dependent current generators in the MTL, we derive relations charact...

  20. Confocal line scanning of a Bessel beam for fast 3D imaging.

    Science.gov (United States)

    Zhang, P; Phipps, M E; Goodwin, P M; Werner, J H

    2014-06-15

    We have developed a light-sheet illumination microscope that can perform fast 3D imaging of transparent biological samples with inexpensive visible lasers and a single galvo mirror (GM). The light-sheet is created by raster scanning a Bessel beam with a GM, with this same GM also being used to rescan the fluorescence across a chip of a camera to construct an image in real time. A slit is used to reject out-of-focus fluorescence such that the image formed in real time has minimal contribution from the sidelobes of the Bessel beam. Compared with two-photon Bessel beam excitation or other confocal line-scanning approaches, our method is of lower cost, is simpler, and does not require calibration and synchronization of multiple GMs. We demonstrated the optical sectioning and out-of-focus background rejection capabilities of this microscope by imaging fluorescently labeled actin filaments in fixed 3T3 cells.

  1. Evaporating droplet hologram simulation for digital in-line holography setup with divergent beam.

    Science.gov (United States)

    Méès, Loïc; Grosjean, Nathalie; Chareyron, Delphine; Marié, Jean-Louis; Seifi, Mozhdeh; Fournier, Corinne

    2013-10-01

    Generalized Lorenz-Mie theory (GLMT) for a multilayered sphere is used to simulate holograms produced by evaporating spherical droplets with refractive index gradient in the surrounding air/vapor mixture. Simulated holograms provide a physical interpretation of experimental holograms produced by evaporating Diethyl Ether droplets with diameter in the order of 50 μm and recorded in a digital in-line holography configuration with a divergent beam. Refractive index gradients in the surrounding medium lead to a modification of the center part of the droplet holograms, where the first fringe is unusually bright. GLMT simulations reproduce this modification well, assuming an exponential decay of the refractive index from the droplet surface to infinity. The diverging beam effect is also considered. In both evaporating and nonevaporating cases, an equivalence is found between Gaussian beam and plane wave illuminations, simply based on a magnification ratio to be applied to the droplets' parameters.

  2. Proposal for characterization of muon spectrometers for neutrino beam lines with the Baby MIND

    CERN Document Server

    Noah, E

    2015-01-01

    Neutrino detectors based on state-of-the-art plastic scintillators read out with solid state photo-sensors, as well as new magnetization schemes, have been developed in the framework of AIDA. Meaningful size prototypes are under construction. In the framework of the CERN neutrino platform, we propose to test a Totally Active Scintillator Detector (TASD) and a prototype of a Magnetized Iron Neutrino Detector (MIND), called Baby MIND in the H8 beam line in 2016-2018. The design of the detectors and the purpose and plans for the beam tests are presented. An opportunity to use the Baby MIND detector in a real neutrino beam at JPARC for the measurement of the cross-section ratio between Water and scintillator (WAGASCI experiment) is described.

  3. A closed-form solution to a viscoelastically supported Timoshenko beam under harmonic line load

    Science.gov (United States)

    Luo, W. L.; Xia, Y.; Zhou, X. Q.

    2016-05-01

    This study aims to formulate a closed-form solution to a viscoelastically supported Timoshenko beam under a harmonic line load. The differential governing equations of motion are converted into algebraic equations by assuming the deflection and rotation of the beam in harmonic forms with respect to time and space. The characteristic equation is biquadratic and thus contains 14 explicit roots. These roots are then substituted into Cauchy's residue theorem; consequently, five forms of the closed-form solution are generated. The present solution is consistent with that of an Euler-Bernoulli beam on a Winkler foundation, which is a special case of the present problem. The current solution is also verified through numerical examples.

  4. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids.

  5. Dosimetric characterization and application of an imaging beam line with a carbon electron target for megavoltage cone beam computed tomography.

    Science.gov (United States)

    Flynn, Ryan T; Hartmann, Julia; Bani-Hashemi, Ali; Nixon, Earl; Alfredo, R; Siochi, C; Pennington, Edward C; Bayouth, John E

    2009-06-01

    Imaging dose from megavoltage cone beam computed tomography (MVCBCT) can be significantly reduced without loss of image quality by using an imaging beam line (IBL), with no flattening filter and a carbon, rather than tungsten, electron target. The IBL produces a greater keV-range x-ray fluence than the treatment beam line (TBL), which results in a more optimal detector response. The IBL imaging dose is not necessarily negligible, however. In this work an IBL was dosimetrically modeled with the Philips Pinnacle3 treatment planning system (TPS), verified experimentally, and applied to clinical cases. The IBL acquisition dose for a 200 degrees gantry rotation was verified in a customized acrylic cylindrical phantom at multiple imaging field sizes with 196 ion chamber measurements. Agreement between the measured and calculated IBL dose was quantified with the 3D gamma index. Representative IBL and TBL imaging dose distributions were calculated for head and neck and prostate patients and included in treatment plans using the imaging dose incorporation (IDI) method. Surface dose was measured for the TBL and IBL for four head and neck cancer patients with MOSFETs. The IBL model, when compared to the percentage depth dose and profile measurements, had 97% passing gamma indices for dosimetric and distance acceptance criteria of 3%, 3 mm, and 100% passed for 5.2%, 5.2 mm. For the ion chamber measurements of phantom image acquisition dose, the IBL model had 93% passing gamma indices for acceptance criteria of 3%, 3 mm, and 100% passed for 4%, 4 mm. Differences between the IBL- and TBL-based IMRT treatment plans created with the IDI method were dosimetrically insignificant for both the prostate and head and neck cases. For IBL and TBL beams with monitor unit values that would result in the delivery of the same dose to the depth of maximum dose under standard calibration conditions, the IBL imaging surface dose was higher than the TBL imaging surface dose by an average of 18

  6. Observations in the SPS of beam with various longitudinal parameters and extracted from the CPS using CT

    CERN Document Server

    Bohl, T

    2009-01-01

    In view of extracting fixed target type of beams for SPS fixed target physics or CNGS operation with the Multi-Turn-Extraction (MTE) scheme, beams with certain sets of longitudinal parameters were produced in the CPS and their transmission in the SPS was studied.

  7. The Beam Line X NdFe-steel hybrid wiggler for SSRL

    Energy Technology Data Exchange (ETDEWEB)

    Hoyer, E.; Halbach, K.; Humphries, D.; Marks, S.; Plate, D.; Shuman, D.; Karpenko, V.P.; Kulkarni, S.; Tirsell, K.G.

    1987-03-10

    A wiggler magnet with 15 periods, each 12.85 cm long, which achieves 1.40 T at a 2.1 cm gap (2.26T at 0.8 cm) has been designed and is now in fabrication at LBL. This wiggler will be the radiation source of the high intensity synchrotron radiation beam line for the Beam Line X PRT facility at SSRL. The magnet utilizes Neodymium-Iron (NdFe) material and Vanadium Permendur (steel) in the hybrid configuration to achieve simultaneously a high magnetic field and short period. Magnetic field adjustment is with a driven chain and ball screw drive system. The magnetic structure is external to an s.s. vacuum chamber which has thin walls, 0.76 mm thickness, at each pole tip for higher field operation. Magnetic design, construction details and magnetic measurements are presented.

  8. National Synchrotron Light Source users manual: Guide to the VUV and x-ray beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Gmuer, N.F.; White-DePace, S.M. (eds.)

    1987-08-01

    The success of the National Synchrotron Light Source in the years to come will be based, in large part, on the size of the users community and the diversity of the scientific disciplines represented by these users. In order to promote this philosophy, this National Synchrotron Light Source (NSLS) Users Manual: Guide to the VUV and X-Ray Beam Lines, has been published. This manual serves a number of purposes. In an effort to attract new research, it will present to the scientific community-at-large the current and projected architecture and capabilities of the various VUV and x-ray beam lines and storage rings. We anticipate that this publication will be updated periodically in order to keep pace with the constant changes at the NSLS.

  9. Electromagnetic Coupling Between High Intensity LHC Beams and the Synchrotron Radiation Monitor Light Extraction System

    CERN Document Server

    Andreazza, W; Bravin, E; Caspers, F; Garlasch`e, M; Gras, J; Goldblatt, A; Lefevre, T; Jones, R; Metral, E; Nosych, A; Roncarolo_, F; Salvant, B; Trad, G; Veness, R; Vollinger, C; Wendt, M

    2013-01-01

    The CERN LHC is equipped with two Synchrotron Radiation Monitor (BSRT) systems used to characterise transverse and longitudinal beam distributions. Since the end of the 2011 LHC run the light extraction system, based on a retractable mirror, has suffered deformation and mechanical failure that is correlated to the increase in beam intensity. Temperature probes have associated these observations to a strong heating of the mirror support with a dependence on the longitudinal bunch length and shape, indicating the origin as electromagnetic coupling between the beam and the structure. This paper combines all this information with the aim of characterising and improving the system in view of its upgrade during the current LHC shutdown. Beam-based observations are presented along with electromagnetic and thermomechanical simulations and complemented by laboratory measurements, including the study of the RF properties of different mirror bulk and coating materials.

  10. Automation of beam based alignment for the PAL-XFEL undulator line

    Energy Technology Data Exchange (ETDEWEB)

    Parc, Yong Woon; Hwang, Ilmoon [Pohang Accelerator Laboratory, Pohang 790-784 (Korea, Republic of); Han, Jang-Hui, E-mail: janghui_han@postech.ac.kr [Pohang Accelerator Laboratory, Pohang 790-784 (Korea, Republic of); Ko, In Soo [Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2015-05-11

    An automated method of quadrupole beam based alignment in an X-ray free electron laser (XFEL) undulator line is proposed. To realize the automatic beam based alignment (BBA) independently of operator's skill and efforts, the procedure is simplified. Simulation results on the BBA technique using two alignment stages for the Pohang Accelerator Laboratory XFEL's (PAL-XFEL) undulator line is carried out. After a standard mechanical alignment the quadrupoles are expected to be aligned to 100 μm rms from our previous experience. A rough alignment method in this study is able to align the quadrupoles to about 40 μm rms without any pre-handling of electron beam orbit or quadrupoles position. At the second stage, the singular value decomposition (SVD) method is applied to perform a fine alignment in which the trajectory of an electron beam is controlled within 5 μm rms to the ideal orbit. All procedures are programmable to perform the BBA automatically.

  11. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  12. Semi-empirical model for fluorescence lines evaluation in diagnostic x-ray beams.

    Science.gov (United States)

    Bontempi, Marco; Andreani, Lucia; Labanti, Claudio; Costa, Paulo Roberto; Rossi, Pier Luca; Baldazzi, Giuseppe

    2016-01-01

    Diagnostic x-ray beams are composed of bremsstrahlung and discrete fluorescence lines. The aim of this study is the development of an efficient model for the evaluation of the fluorescence lines. The most important electron ionization models are analyzed and implemented. The model results were compared with experimental data and with other independent spectra presented in the literature. The implemented peak models allow the discrimination between direct and indirect radiation emitted from tungsten anodes. The comparison with the independent literature spectra indicated a good agreement.

  13. Off-line production of intense {sup 7,10}Be{sup +} beams

    Energy Technology Data Exchange (ETDEWEB)

    Koester, U. E-mail: ulli.koster@cern.ch; Argentini, M.; Catherall, R.; Fedoseyev, V.N.; Gaeggeler, H.W.; Jonsson, O.C.; Weinreich, R

    2003-05-01

    {sup 7}Be and {sup 10}Be were produced by 590 MeV proton bombardment of a graphite target at PSI. Parts of this graphite target were transferred into an ISOLDE target and ion source unit and ionized with the ISOLDE resonance ionization laser ion source. Thus intense radioactive ion beams of 300 nA of {sup 7,10}Be{sup +} were produced off-line.

  14. Off-line production of intense $^{7,10}Be^{+}$ beams

    CERN Document Server

    Köster, U; Catherall, R; Fedosseev, V; Gäggeler, H W; Jonsson, O C; Weinreich, R

    2003-01-01

    $^7$Be and $^{10}$Be were produced by 590~MeV proton bombardment of a graphite target at PSI. Parts of this graphite target were transferred into an ISOLDE target and ion source unit and ionized with the ISOLDE resonance ionization laser ion source (RILIS). Thus intense radioactive ion beams of 300~nA of $^{7,10}$Be$^+$ were produced off-line.

  15. Light-sheet microscopy by confocal line scanning of dual-Bessel beams.

    Science.gov (United States)

    Zhang, Pengfei; Phipps, Mary E; Goodwin, Peter M; Werner, James H

    2016-10-01

    We have developed a light-sheet microscope that uses confocal scanning of dual-Bessel beams for illumination. A digital micromirror device (DMD) is placed in the intermediate image plane of the objective used to collect fluorescence and is programmed with two lines of pixels in the “on” state such that the DMD functions as a spatial filter to reject the out-of-focus background generated by the side-lobes of the Bessel beams. The optical sectioning and out-of-focus background rejection capabilities of this microscope were demonstrated by imaging of fluorescently stained actin in human A431 cells. The dual-Bessel beam system enables twice as many photons to be detected per imaging scan, which is useful for low light applications (e.g., single-molecule localization) or imaging at high speed with a superior signal to noise. While demonstrated for two Bessel beams, this approach is scalable to a larger number of beams.

  16. Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results

    Science.gov (United States)

    Garg, Akash Deep; Karnewar, A. K.; Ojha, A.; Shrivastava, B. B.; Holikatti, A. C.; Puntambekar, T. A.; Navathe, C. P.

    2014-08-01

    Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8-18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 μm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.

  17. Preliminary Simulation of Beam Extraction for the 28 GHz ECR Ion Source

    CERN Document Server

    Park, Bum-Sik; Choi, Seokjin

    2015-01-01

    The 28 GHz ECR(Electron Cyclotron Resonance) ion source is under development to supply various beams from proton to uranium at RISP(Rare Isotope Science Project). The superconducting magnet system for a 28 GHz ECR ion source consists of four solenoid coils and a saddle type sextupole. To meet the design requirement of ECR ion source, a numerical simulation was accomplished by using the KOBRA3-INP to optimize the extraction system which is the three dimensional ion optics code. The influence of the three dimensional magnetic field and the space charge effect was considered to extract the highly charged ion beam. In this paper, the design results of the extraction system were reported in detail.

  18. Design of medium energy beam transport line between the RFQ and the Linac in the radioactive ion beam facility at VECC, Kolkata

    Indian Academy of Sciences (India)

    S Dechoudhury; Vaishali Naik; Manas Mondal; Hemendra Kumar Pandey; Avik Chatterjee; Dirtha Sanyal; Debasis Bhowmick; Alok Chakrabarti

    2010-09-01

    The design of a medium energy beam transport (MEBT) line comprising of a re-buncher and four quadrupoles, two upstream and the other two downstream of the re-buncher, has been presented. The design was done to ensure almost 100% transport of heavy-ion beams of about 99 keV/u energy from RFQ having a / not less than 1/14 through the re-buncher and then through IH Linac of about 0.6 m length in which beam would be accelerated to about 185 keV/u. The re-buncher has been designed to operate at 37.8 MHz, the resonating frequency of both the RFQ and the IH Linac. The entire beam line has been installed and recently O5+ beam from RFQ has been transported through the re-buncher and subsequently accelerated in the IH Linac successfully.

  19. Analysis of the Interactions of Botanical Extract Combinations Against the Viability of Prostate Cancer Cell Lines

    Directory of Open Access Journals (Sweden)

    Lynn S. Adams

    2006-01-01

    Full Text Available Herbal medicines are often combinations of botanical extracts that are assumed to have additive or synergistic effects. The purpose of this investigation was to compare the effect of individual botanical extracts with combinations of extracts on prostate cell viability. We then modeled the interactions between botanical extracts in combination isobolographically. Scutellaria baicalensis, Rabdosia rubescens, Panax-pseudo ginseng, Dendranthema morifolium, Glycyrrhiza uralensis and Serenoa repens were collected, taxonomically identified and extracts prepared. Effects of the extracts on cell viability were quantitated in prostate cell lines using a luminescent ATP cell viability assay. Combinations of two botanical extracts of the four most active extracts were tested in the 22Rv1 cell line and their interactions assessed using isobolographic analysis. Each extract significantly inhibited the proliferation of prostate cell lines in a time- and dose-dependent manner except repens. The most active extracts, baicalensis, D. morifolium, G. uralensis and R. rubescens were tested as two-extract combinations. baicalensis and D. morifolium when combined were additive with a trend toward synergy, whereas D. morifolium and R. rubescens together were additive. The remaining two-extract combinations showed antagonism. The four extracts together were significantly more effective than the two-by-two combinations and the individual extracts alone. Combining the four herbal extracts significantly enhanced their activity in the cell lines tested compared with extracts alone. The less predictable nature of the two-way combinations suggests a need for careful characterization of the effects of each individual herb based on their intended use.

  20. Extraction of Roof Lines from High-Resolution Images by a Grouping Method

    Science.gov (United States)

    Dal Poz, A. P.; Fernandes, V. J. M.

    2016-06-01

    This paper proposes a method for extracting groups of straight lines that represent roof boundaries and roof ridgelines from highresolution aerial images using corresponding Airborne Laser Scanner (ALS) roof polyhedrons as initial approximations. The proposed method is based on two main steps. First, straight lines that are candidates to represent roof ridgelines and roof boundaries of a building are extracted from the aerial image. Second, a group of straight lines that represent roof boundaries and roof ridgelines of a selected building is obtained through the optimization of a Markov Random Field (MRF)-based energy function using the genetic algorithm optimization method. The formulation of this energy function considers several attributes, such as the proximity of the extracted straight lines to the corresponding projected ALS-derived roof polyhedron and the rectangularity (extracted straight lines that intersect at nearly 90°). Experimental results are presented and discussed in this paper.

  1. Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

    Directory of Open Access Journals (Sweden)

    2010-04-01

    Full Text Available ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.

  2. Beam extraction from a laser-driven multicharged ion source (abstract)

    Science.gov (United States)

    Anderson, O. A.; Logan, B. Grant

    1998-02-01

    A newly proposed type of multicharged ion source has several potential advantages over existing types and a number of useful applications. The basic principle is that multiphoton absorption in an intense uniform laser focus can give multiple charge states of high purity (Ref. Reference 1). Thus, charge state separation downstream is simplified or made unnecessary. Another advantage is that large currents (hundreds of amperes) can be extracted. This type of source could be used for heavy-ion fusion drivers (see Ref. Reference 1) or storage rings. There are also industrial application such as materials processing. We describe conceptual design studies for several specific cases. For example, we discuss extraction and focusing of a 4.1 MV, 144 A beam of Xe16+ ions from an expanding plasma created by an intense laser. The maximum duration of the beam pulse is determined by the total charge in the plasma, while the practical pulse length is determined by the range of plasma radii over which good beam optics can be achieved. The initially diverging beam can be refocused to a small radius or made parallel by a combination of electrostatic and solenoid focusing. Our design studies are carried out first with an envelope code to determine the proper focusing parameters and then with a self-consistent particle code to optimize the beam quality. We present results from both codes and discuss several applications of this type of ion source.

  3. Extracting curved text lines using the chain composition and the expanded grouping method

    Science.gov (United States)

    Noi Bai, Nguyen; Nam, Kim; Song, Youngjun

    2008-01-01

    In this paper, we present a method to extract the text lines in poorly structured documents. The text lines may have different orientations, considerably curved shapes, and there are possibly a few wide inter-word gaps in a text line. Those text lines can be found in posters, blocks of addresses, artistic documents. Our method is an expansion of the traditional perceptual grouping. We develop novel solutions to overcome the problems of insufficient seed points and varied orientations in a single line. In this paper, we assume that text lines consists of connected components, in which each connected components is a set of black pixels within a letter, or some touched letters. In our scheme, the connected components closer than an iteratively incremented threshold will be combined to make chains of connected components. Elongate chains are identified as the seed chains of lines. Then the seed chains are extended to the left and the right regarding the local orientations. The local orientations will be reevaluated at each side of the chains when it is extended. By this process, all text lines are finally constructed. The advantage of the proposed method over prior works in extraction of curved text lines is that this method can both deal with more than a specific language and extract text lines containing some wide inter-word gaps. The proposed method is good for extraction of the considerably curved text lines from logos and slogans in our experiment; 98% and 94% for the straight-line extraction and the curved-line extraction, respectively.

  4. Characteristics of the negative ion beam extracted from an LBL multicusp volume source

    Energy Technology Data Exchange (ETDEWEB)

    Debiak, T.W.; Solensten, L.; Sredniawski, J.J.; Ng, Y.C.; Heuer, R. (Grumman Corporation, Bethpage, New York 11714 (US))

    1990-01-01

    This work encompasses a study of the beam position, profile, and emittance of a Lawrence Berkeley Lab (LBL) multicusp volume source. The study includes a comparison of different extraction geometries with single- and multiple-hole apertures. Our work is currently based on single-gap extraction and acceleration. These experiments are the first of a planned series of studies with various extractor geometries. The beam profile full width at half-maximum ranged from 5.7 to 10.2 mm at a position 69 mm from the emission aperture. Measurements of profile and position in the vertical direction indicate that the beam is significantly bent in the direction expected due to the field of the electron separation magnet. Phase space contour plots in the horizontal plane have been obtained for circular extraction apertures with a diameter of 1.0 and 2.0 mm, and a multiple-hole aperture with an overall diameter of 2.46 mm. Emittances were calculated to be as low as 0.0010 {pi} cm mrad for the 1-mm aperture and 0.0014 {pi} cm mrad for the 2-mm aperture. Emittances are not reported for the multiple-hole aperture due to the shape of the phase space contours; however, analysis of the data is in progress to provide a meaningful comparison of the single-hole and multiple-hole beam characteristics.

  5. Selective cytotoxic activity of grape peel and seed extracts against oral tumor cell lines.

    Science.gov (United States)

    Shirataki, Y; Kawase, M; Saito, S; Kurihara, T; Tanaka, W; Satoh, K; Sakagami, H; Motohashi, N

    2000-01-01

    Grape seed extracts were more cytotoxic than grape peel extracts. Methanol and 70% methanol extracts of grape seed selectively killed two human oral tumor cell lines, more efficiently than human gingival fibroblasts. ESR spectroscopy revealed that these extracts produced radicals under alkaline conditions and enhanced the radical intensity of sodium ascorbate at higher concentrations. On the other hand, lower concentration of these extracts slightly reduced the radical intensity of sodium ascorbate, and scavenged superoxide anion, generated by hypoxanthine and xanthine oxidase reaction. These properties of grape seed extracts suggest their possible application for cancer prevention.

  6. On-line neutron beam monitoring of the Finnish BNCT facility

    Science.gov (United States)

    Tanner, Vesa; Auterinen, Iiro; Helin, Jori; Kosunen, Antti; Savolainen, Sauli

    1999-02-01

    A Boron Neutron Capture Therapy (BNCT) facility has been built at the FiR 1 research reactor of VTT Chemical Technology in Espoo, Finland. The facility is currently undergoing dosimetry characterisation and neutron beam operation research for clinical trials. The healthy tissue tolerance study, which was carried out in the new facility during spring 1998, demonstrated the reliability and user-friendliness of the new on-line beam monitoring system designed and constructed for BNCT by VTT Chemical Technology. The epithermal neutron beam is monitored at a bismuth gamma shield after an aluminiumfluoride-aluminium moderator. The detectors are three pulse mode U 235-fission chambers for epithermal neutron fluence rate and one current mode ionisation chamber for gamma dose rate. By using different detector sensitivities the beam intensity can be measured over a wide range of reactor power levels (0.001-250 kW). The detector signals are monitored on-line with a virtual instrumentation (LabView) based PC-program, which records and displays the actual count rates and total counts of the detectors in the beam. Also reactor in-core power instrumentation and control rod positions can be monitored via another LabView application. The main purpose of the monitoring system is to provide a dosimetric link to the dose in a patient during the treatment, as the fission chamber count rates have been calibrated to the induced thermal neutron fluence rate and to the absorbed dose rate at reference conditions in a tissue substitute phantom.

  7. Transverse beam splitting made operational: Key features of the multiturn extraction at the CERN Proton Synchrotron

    Directory of Open Access Journals (Sweden)

    A. Huschauer

    2017-06-01

    Full Text Available Following a successful commissioning period, the multiturn extraction (MTE at the CERN Proton Synchrotron (PS has been applied for the fixed-target physics programme at the Super Proton Synchrotron (SPS since September 2015. This exceptional extraction technique was proposed to replace the long-serving continuous transfer (CT extraction, which has the drawback of inducing high activation in the ring. MTE exploits the principles of nonlinear beam dynamics to perform loss-free beam splitting in the horizontal phase space. Over multiple turns, the resulting beamlets are then transferred to the downstream accelerator. The operational deployment of MTE was rendered possible by the full understanding and mitigation of different hardware limitations and by redesigning the extraction trajectories and nonlinear optics, which was required due to the installation of a dummy septum to reduce the activation of the magnetic extraction septum. This paper focuses on these key features including the use of the transverse damper and the septum shadowing, which allowed a transition from the MTE study to a mature operational extraction scheme.

  8. Simulation study of beam extraction from a synchrotron using colored noise with digital filter

    Science.gov (United States)

    Nakanishi, Tetsuya; Tsuruha, Kohei

    2009-09-01

    A simulation program is developed for a slow-extraction method using a fast Q magnet (FQ) and an RF-knockout. In this extraction method, after the separatrix is produced with excitation of sextupole magnets, a required quantity of circulating beam is extracted by shrinking the separatrix with excitation of the FQ. Then the emittance of circulating beam is diffused to an original size with the RF-knockout. This process is repeated with required timing until the entire circulating beam is completely extracted. An algorithm using a digital filter and white noise is proposed for a colored noise as a signal source for the RF-knockout. Spill structures with the present computing method were similar to the results obtained using a conventional algorithm with the sum of cosines of many frequency components. The results are also in agreement with the experimental results using the HIMAC synchrotron. The computing time of colored noise for simulation of 10 6 turns was 0.5 h for the filter method and 5.0 h for the conventional one. It is indicated that a colored noise with a wider frequency bandwidth gives a better spill structure that smoothly increases with time.

  9. Simulation of the CERN GTS-LHC ECR ion source extraction system with lead and argon ion beams

    CERN Document Server

    Toivanen, V; Küchler, D; Lombardi, A; Scrivens, R; Stafford-Haworth, J

    2014-01-01

    A comprehensive study of beam formation and beam transport has been initiated in order to improve the performance of the CERN heavy ion injector, Linac3. As part of this study, the ion beam extraction system of the CERN GTS-LHC 14.5 GHz Electron Cyclotron Resonance Ion Source (ECRIS) has been modelled with the ion optical code IBSimu. The simulations predict self-consistently the triangular and hollow beam structures which are often observed experimentally with ECRIS ion beams. The model is used to investigate the performance of the current extraction system and provides a basis for possible future improvements. In addition, the extraction simulation provides a more realistic representation of the initial beam properties for the beam transport simulations, which aim to identify the performance bottle necks along the Linac3 low energy beam transport. The results of beam extraction simulations with Pb and Ar ion beams from the GTS-LHC will be presented and compared with experimental observations.

  10. Composite cone-beam filtered backprojection algorithm based on nutating line

    Institute of Scientific and Technical Information of China (English)

    WANG Yu; OU Zong-ying; SU Tie-ming; WANG Feng

    2006-01-01

    The FDK algorithm is the most popular cone beam algorithm in the medical and industrial imaging field.Due to data insufficiency acquired from a circular trajectory,the images reconstructed by the FDK algorithm suffer from the intensity droping with increasing cone angle.To overcome the drawback,a modified FDK algorithm is presented by convert the 1D ramp filtering direction from along the horizontal lines to along the nutating lines based on the result of Turbell.Unlike Turbell's method,there is no need for our algorithm to rebin the cone-beam data into 3D parallel-beam data before reconstructing.Moreover pre-weighting of the projection data is corrected by compensating for the cone angle effect.In addition,another correction term derived from the result of Hu is also induced into our algorithm.The simulation experiments demonstrate that the final algorithm can suppress the intensity drop associated with the FDK algorithm.

  11. The IFUSP microtron accelerator beam transport line; Linha de transporte de feixe do acelerador microtron do IFUSP

    Energy Technology Data Exchange (ETDEWEB)

    Rios, Paulo Beolchi

    2002-07-01

    In this work, the electron optical project of the IFUSP microtron beam transport line is presented, including the operational values for the parameters of the dipolar and quadrupolar electromagnets, as well as their location along the beam line. Analytical calculations and computer simulations were performed to obtain these results, and a programming tool was developed in order to analyze the beam parameters and to help studying racetrack microtrons. The electron optical simulations were split into two different study cases: the microtron booster, and the transfer line. In the first case, it was determined the main operational parameters of a microtron working far from its usual stability conditions. In the latter, it was done the basic design of the linking line between the booster and main (not yet built) microtrons, and between them and the experimental hall, with a total path length of approximately 32 m including large horizontal and vertical deflections with variable beam energy. (author)

  12. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.

    Science.gov (United States)

    Harty, P D; Lye, J E; Ramanathan, G; Butler, D J; Hall, C J; Stevenson, A W; Johnston, P N

    2014-05-01

    The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. The good agreement of

  13. Target and orbit feedback simulations of a muSR beam line at BNL

    Energy Technology Data Exchange (ETDEWEB)

    MacKay, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pile, P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-07-28

    Well-polarized positive surface muons are a tool to measure the magnetic properties of materials since the precession rate of the spin can be determined from the observation of the positron directions when the muons decay. For a dc beam an ideal µSR flux for surface µ+ should be about 40 kHz/mm2. In this report we show how this flux could be achieved in a beam line using the AGS complex at BNL for a source of protons. We also determined that an orbit feedback system with a pair of thin silicon position monitors and kickers would miss the desired flux by at least an order of magnitude, even with perfect time resolution and no multiple scattering.

  14. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  15. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  16. Design of a two-ion-source (2-IS) beam transport line for the production of multi charged radioactive ion beams

    CERN Document Server

    Banerjee, V; Bandyopadhyay, A; Chattopadhyay, S; Polley, A; Nakagawa, T; Kamigaito, O; Goto, A; Yano, Y

    2000-01-01

    A 'two-ion-source' beam transport line between a surface ionization source and a 6.4 GHz on-line Electron Cyclotron Resonance Ion Source (ECRIS) for the production of multi-charged radioactive ions has been designed. The 1 sup + ions from the surface ionization source are decelerated and focused onto the ECRIS plasma so that they can be efficiently trapped there and further ionized to charge state q>1 sup +. A scheme for stepwise and gradual deceleration of the 1 sup + ion beam consisting of a multi-electrode decelerator and a tuning electrode placed before the ECRIS has been optimized. The beam dynamics calculations show that the 1 sup + beam decelerated to energies of 20-50 eV could be focused to a spot size smaller than the radial dimensions of the ECR plasma zone.

  17. Bent crystal channeling applications for beam splitting, extraction and collimation in the U-70 accelerator of IHEP

    Energy Technology Data Exchange (ETDEWEB)

    Chesnokov, Yu.A., E-mail: chesnokov@ihep.ru; Afonin, A.G.; Baranov, V.T.; Britvich, G.I.; Chirkov, P.N.; Maisheev, V.A.; Terekhov, V.I.; Yazynin, I.A.

    2013-08-15

    The report presents an overview of the results of IHEP activity obtained during 1987-2012 in the field of studying and using bent crystals to steer high-energy particle beams. The hardware installed to study crystal beam splitting, collimation and extraction is described. It has been shown that the developed crystal deflectors are capable for sustaining long-term operation to deliver high-energy extracted beams for fixed-target physics. The first results on extraction of 24.1 GeV/nucleon carbon ions are also presented.

  18. Development and construction of a neutron beam line for accelerator-based boron neutron capture synovectomy.

    Science.gov (United States)

    Gierga, D P; Yanch, J C; Shefer, R E

    2000-01-01

    A potential application of the 10B(n, alpha)7Li nuclear reaction for the treatment of rheumatoid arthritis, termed Boron Neutron Capture Synovectomy (BNCS), is under investigation. In an arthritic joint, the synovial lining becomes inflamed and is a source of great pain and discomfort for the afflicted patient. The goal of BNCS is to ablate the synovium, thereby eliminating the symptoms of the arthritis. A BNCS treatment would consist of an intra-articular injection of boron followed by neutron irradiation of the joint. Monte Carlo radiation transport calculations have been used to develop an accelerator-based epithermal neutron beam line for BNCS treatments. The model includes a moderator/reflector assembly, neutron producing target, target cooling system, and arthritic joint phantom. Single and parallel opposed beam irradiations have been modeled for the human knee, human finger, and rabbit knee joints. Additional reflectors, placed to the side and back of the joint, have been added to the model and have been shown to improve treatment times and skin doses by about a factor of 2. Several neutron-producing charged particle reactions have been examined for BNCS, including the 9Be(p,n) reaction at proton energies of 4 and 3.7 MeV, the 9Be(d,n) reaction at deuteron energies of 1.5 and 2.6 MeV, and the 7Li(p,n) reaction at a proton energy of 2.5 MeV. For an accelerator beam current of 1 mA and synovial boron uptake of 1000 ppm, the time to deliver a therapy dose of 10,000 RBEcGy ranges from 3 to 48 min, depending on the treated joint and the neutron producing charged particle reaction. The whole-body effective dose that a human would incur during a knee treatment has been estimated to be 3.6 rem or 0.75 rem, for 1000 ppm or 19,000 ppm synovial boron uptake, respectively, although the shielding configuration has not yet been optimized. The Monte Carlo design process culminated in the construction, installation, and testing of a dedicated BNCS beam line on the high

  19. Research on the Algorithm of Extracting Ridge and Valley Lines from Contour Data

    Institute of Scientific and Technical Information of China (English)

    JIN Hailiang; GAO Jingxiang

    2005-01-01

    In this paper, the authors put forward a brief and practical arithmetic for auto extracting terrain lines from digital terrain data after analyzing and comparing current arithmetics. This paper gives an experiment result that the ridge and valley extracted by the arithmetic is consistent with the experimental terrain.

  20. On-line coupling of supercritical fluid extraction and chromatographic techniques.

    Science.gov (United States)

    Sánchez-Camargo, Andrea Del Pilar; Parada-Alfonso, Fabián; Ibáñez, Elena; Cifuentes, Alejandro

    2017-01-01

    This review summarizes and discusses recent advances and applications of on-line supercritical fluid extraction coupled to liquid chromatography, gas chromatography, and supercritical fluid chromatographic techniques. Supercritical fluids, due to their exceptional physical properties, provide unique opportunities not only during the extraction step but also in the separation process. Although supercritical fluid extraction is especially suitable for recovery of non-polar organic compounds, this technique can also be successfully applied to the extraction of polar analytes by the aid of modifiers. Supercritical fluid extraction process can be performed following "off-line" or "on-line" approaches and their main features are contrasted herein. Besides, the parameters affecting the supercritical fluid extraction process are explained and a "decision tree" is for the first time presented in this review work as a guide tool for method development. The general principles (instrumental and methodological) of the different on-line couplings of supercritical fluid extraction with chromatographic techniques are described. Advantages and shortcomings of supercritical fluid extraction as hyphenated technique are discussed. Besides, an update of the most recent applications (from 2005 up to now) of the mentioned couplings is also presented in this review.

  1. Cytotoxicity screening of Melastoma malabathricum extracts on human breast cancer cell lines in vitro

    Directory of Open Access Journals (Sweden)

    Nurfariza Ahmad Roslen

    2014-07-01

    Conclusions: The extracts from leaves and flowers of M. malabathricum showed promising anticancer activity toward human breast cancer cell lines with the lowest IC50 at 7.14 μg/mL while the extracts from stems showed less growth inhibition activity.

  2. Millimeter-Wave Line Ratios and Sub-beam Volume Density Distributions

    CERN Document Server

    Leroy, Adam K; Schruba, Andreas; Bigiel, Frank; Kruijssen, J M Diederik; Kepley, Amanda; Blanc, Guillermo A; Bolatto, Alberto D; Cormier, Diane; Gallagher, Molly; Hughes, Annie; Jimenez-Donaire, Maria J; Rosolowsky, Erik; Schinnerer, Eva

    2016-01-01

    We explore the use of mm-wave emission line ratios to trace molecular gas density when observations integrate over a wide range of volume densities within a single telescope beam. For observations targeting external galaxies, this case is unavoidable. Using a framework similar to that of Krumholz and Thompson (2007), we model emission for a set of common extragalactic lines from lognormal and power law density distributions. We consider the median density of gas producing emission and the ability to predict density variations from observed line ratios. We emphasize line ratio variations, because these do not require knowing the absolute abundance of our tracers. Patterns of line ratio variations have the prospect to illuminate the high-end shape of the density distribution, and to capture changes in the dense gas fraction and median volume density. Our results with and without a high density power law tail differ appreciably; we highlight better knowledge of the PDF shape as an important area. We also show th...

  3. 100 years of elementary particles [Beam Line, vol. 27, issue 1, Spring 1997

    Energy Technology Data Exchange (ETDEWEB)

    Pais, Abraham; Weinberg, Steven; Quigg, Chris; Riordan, Michael; Panofsky, Wolfgang K.H.; Trimble, Virginia

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  4. 100 years of Elementary Particles [Beam Line, vol. 27, issue 1, Spring 1997

    Science.gov (United States)

    Pais, Abraham; Weinberg, Steven; Quigg, Chris; Riordan, Michael; Panofsky, Wolfgang K. H.; Trimble, Virginia

    1997-04-01

    This issue of Beam Line commemorates the 100th anniversary of the April 30, 1897 report of the discovery of the electron by J.J. Thomson and the ensuing discovery of other subatomic particles. In the first three articles, theorists Abraham Pais, Steven Weinberg, and Chris Quigg provide their perspectives on the discoveries of elementary particles as well as the implications and future directions resulting from these discoveries. In the following three articles, Michael Riordan, Wolfgang Panofsky, and Virginia Trimble apply our knowledge about elementary particles to high-energy research, electronics technology, and understanding the origin and evolution of our Universe.

  5. Design and construction of UVSOR-BL4A2 beam line for nano-structure processing

    CERN Document Server

    Takezoe, N; Tanaka, T; Kurosawa, K; Nonogaki, Y; Noda, H; Mekaru, H; Urisu, T

    2001-01-01

    We have designed and constructed a new beam line BL4A2 at UVSOR mainly for nano-structure fabrication based on synchrotron radiation stimulated surface photochemical reactions. In order to obtain high-photon flux, we use white ray beam focused with only one mirror. The beam line is connected with ultra-high vacuum scanning tunneling microscope for in-situ atomic scale observations, low energy electron diffraction and Auger electron spectroscope for surface crystal structure characterization, and photo-stimulated surface reaction chamber. In order to monitor the optical properties with atomic scale, a near field optical microscope is planned to be installed.

  6. A new method for extraction of approximately vertical lines from natural images

    Institute of Scientific and Technical Information of China (English)

    赵建坤; 吴江华; 张田文

    2002-01-01

    For natural images with complex background and noise, this new approach appears is more effective than other techniques for three key reasons: 1)edge elements treated interdependently to overcome the weakness of standard Hough transform (HT); 2)gradient orientation information taken into account in the process of HT; 3) an effective method used to "merge" the HT result, i.e. many "clustered short lines" into single straight line to represent the edge of object to be recognized. This method consists of three steps are: 1) edge detection; 2)modified Hough transform to extract "clustered short lines"; 3) merging "clustered short lines" into a single line after few modifications. The method presented in this paper could also be used for extraction of non-vertical straight lines.

  7. The charge breeder beam line for the selective production of exotic species project at INFN-Legnaro National Laboratories

    Science.gov (United States)

    Galatà, A.; Comunian, M.; Maggiore, M.; Manzolaro, M.; Angot, J.; Lamy, T.

    2014-02-01

    SPES (Selective Production of Exotic Species) is an INFN (Istituto Nazionale di Fisica Nucleare) project with the aim at producing and post-accelerating exotic beams to perform forefront research in nuclear physics. To allow post-acceleration of the radioactive ions, an ECR-based Charge Breeder (CB) developed on the basis of the Phoenix booster was chosen. The design of the complete beam line for the SPES-CB will be described: a system for stable 1+ beams production was included; special attention was paid to the medium resolution mass spectrometer after the CB to limit possible superposition of the exotic beams with the impurities present in the ECR plasma.

  8. An adjustable focusing system for a 2 MeV H- ion beam line based on permanent magnet quadrupoles

    CERN Document Server

    Nirkko, M; Ereditato, A; Kreslo, I; Scampoli, P; Weber, M

    2012-01-01

    A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.

  9. Effects of Dioscin Extracted from Polygonatum Zanlanscianense Pamp on Several Human Tumor Cell Lines

    Institute of Scientific and Technical Information of China (English)

    王钊; 周江兵; 巨勇; 姚沈勤; 张洪钧

    2001-01-01

    Dioscin was extracted and isolated from Polygonatum Zanlanscianense Pamp. The effects of dioscin on HL60, HeLa, H14, and MDA-MB-435 cell lines were studied with the results showing that dioscin dramatically inhibited the growth of the MDA-MB-435, H14, HL60, and HeLa cell lines. The IC50 of dioscin on these cell lines were 2.6, 0.8, 7. 5, and 4.5 μ mol/L respectively.

  10. On-line Scanned Probe Microscopy Transparently Integrated with DualBeam SEM/FIB Systems

    Science.gov (United States)

    Ignatov, Andrey; Komissar, Anatoly; Lewis, Aaron

    2013-03-01

    A multifunctional scanning probe microscope (SPM) will be described that transparently integrates with a DualBeam SEM/FIB System. This is done without perturbing any of the capabilities of the Dual Beam in terms of detectors, gas injectors, analyzers etc while allowing for a completely exposed probe tip to be imaged online even with immersion objectives at working distances as short as 4 mm. In addition, the completely free motion of the rotation axis of the stage is maintained with the probe tip at the eucentric point, this makes it possible to orient the sample in any direction on any structure The X and Y scan range of the atomic force microscopic (AFM) imaging achieves 35 microns with rough motion over 10 millimeters. This permits the SPM to tilt into position perpendicular to the SEM or FIB or under an angle for rapid and accurate placement of the probe tip at or on structures such as biopolymeric materials that are nanometric in X, Y and Z extent. Thus, not only can a structure's nanometric height be accurately profiled but this can be accomplished with the on-line excellence of SEM for X, Y metrology. Furthermore, electron and ion beam sensitive samples can be imaged and characterized by AFM at high resolution.

  11. Beryllium window and acoustic delay line design for x-ray lithography beam lines at the University of Wisconsin Center for X-ray Lithography

    Science.gov (United States)

    Brodsky, E. L.; Hamilton, W.; Wells, G.; Cerrina, F.; Corradini, M.

    1992-01-01

    X-ray lithography systems require sample chambers that can perform exposures in helium gas at atmospheric pressure. The interface between the experimental chamber and the beamline is critical for x-ray lithography and the storage ring. It must allow a high x-ray flux throughput while providing a vacuum barrier so that helium gas does not leak into the beam line and the storage ring. The beam line must also be designed to have protection in the case that a window does fail in order to minimize adverse effects to the ring and other systems. The details of the design for the vacuum system used on beam lines for the Center for X-ray Lithography at the University of Wisconsin Synchrotron Radiation Center 1-GeV electron storage ring are reported. Curved beryllium windows with a 1×5-cm2 aperture and 13 μm thick that have a leak rate less than 10-10 Torr l/s have been successfully used at the experimental chamber beam-line interface. This thin flat beryllium foil is mounted in a curved housing with a wire seal to minimize helium leakage. The window assembly is designed and has been tested to withstand substantial overpressure before failure. If the beryllium window does fail, the beamline has an acoustic delay line that is designed to delay the incoming shock wave of helium gas so that a fast valve at the end of the beam line will close and minimize leakage of helium into the storage ring. The acoustic delay line is designed with baffles to slow the shock front and a secondary thin window to protect against molecular diffusion into the storage ring. The acoustic delay line has been tested to determine the effect of baffle design on delay of the shock wave. A theoretical model that provides a good description of the acoustic delay has also been developed.

  12. The First Experience With Space Scanning Extracted Beam On The Spin@u-70 Setup Target Possibility And Measurement Tool

    CERN Document Server

    Afonin, A G; Gres, V N; Terekhov, V I

    2004-01-01

    This paper presents the first results of experiments aimed at a provision of possibilities of the extracted beam space scanning on polarized target of the SPIN@U-70 Setup. The design and features of the special instrumentation are given.

  13. Cytotoxicity screening of Melastoma malabathricum extracts on human breast cancer cell lines in vitro

    Institute of Scientific and Technical Information of China (English)

    Nurfariza Ahmad Roslen; Nur Aizura Mat Alewi; Hadji Ahamada

    2014-01-01

    Objective: To screen the cytotoxic activity of Melastoma malabathricum (M. malabathricum) against human breast cancer cell line (MCF-7) in vitro. Methods: A three steps extraction protocol using n-hexane, chloroform and methanol as the solvents systems was carried out on leaves, stems and flowers of M. malabathricum. Dimethyl sulfoxide was used in extracts dilution and serial dilutions were conducted to obtain five different extract concentrations (100 µg/mL, 50 µg/mL, 25 µg/mL, 12.5 µg/mL and 6.25 µg/mL). The evaluation of cell growth was determined using methylene blue assay.Results:Methanol extract from the leaves showed significant anticancer activity against MCF-7 cell lines with the IC50 value of 7.14 µg/ml while methanol and chloroform extract from the flowers exhibited a moderate activity towards MCF-7 cell line with the IC50 value of 33.63 µg/mL and 45.76 µg/mL respectively after 72 h of treatment.Conclusions:The extracts from leaves and flowers of M. malabathricum showed promising anticancer activity toward human breast cancer cell lines with the lowest IC50 at 7.14 µg/mL while the extracts from stems showed less growth inhibition activity.

  14. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan

    2016-09-01

    We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200 μ m , for two final bunch charges: 1 05 electrons (16 fC) and 1 06 electrons (160 fC). Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of Lc ,x/σx=0.27 nm /μ m was obtained for a final bunch charge of 1 05 electrons and final bunch length of σt≈100 fs . For a final charge of 1 06 electrons the cryogun produces Lc ,x/σx≈0.1 nm /μ m for σt≈100 - 200 fs and σx≥50 μ m . These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  15. Study of Slow Beam Extraction Through the Third Order Resonance with Transverse Phase Space Manipulation by a Mono-Frequency RFKO

    CERN Document Server

    Miyamoto, Atsushi; Hinode, Fujio; Kawai, Masayuki; Shinto, Katsuhiro; Tanaka, Takumi

    2005-01-01

    An electron pulse-stretcher ring (STB ring) has a function which converts a pulse beam generated by RF linac into a quasi-continuous beam. Circulating beam in the ring is extracted by the third order resonance. Since there is no accelerating field in the ring, the beam approaches a transverse resonance condition due to synchrotron radiation loss with finite chromaticity. The extracted beam from the ring has some spread in time and space corresponding to injected beam from linac even if the injected beam is perfectly matched to the ring optics. However, the extracted beam emittance can be reduced by applying a phase space manipulation using an RF shaker. Under the influence of perturbation using an RF shaker driven by a mono-frequency, the betatron amplitude of circulating beam can be controlled in order to reduce the extracted beam emittance. The experimental results will be reported in this conference.

  16. Reliable image straight-line extraction based on the integration of intensity discontinuity and edge continuity

    Science.gov (United States)

    Wu, Jun

    2009-10-01

    This paper describes general framework of extraction of image straight-line segments based on the integration of intensity discontinuity and edge continuity in digital image. First, multiple "edge contours" are traced out from digital image by implementing classic LOG algorithm and contour tracing principle. In this step, Zero-Cross points are detected without implementing traditional 'edge labeling' procedure and thus, the continuity between adjacent edge points are maintained for the convenience of edge linking and can take advantage of contour tracing principle; After that, Houghbased heuristic linking algorithm is developed to extract initial straight-line segments from "edge contour" respectively. In this step, important prior knowledge, e.g., "seed" point and direction of straight-line segments, is deduced from Hough transformation and based on the knowledge, possible straight-line segments contained in each "edge contour" are extracted through heuristic linking via adjacent continuity again; Finally, initial straight-line segments are testified and improved with Least Squares Template Matching (LSTM) technique by estimating the similarity of intensity distribution between initial straight-line segment and its ideal intensity template. The experiment of extracting straight-line segments from aerial or ground image respectively, for building 3D reconstruction demonstrates that the proposed approach is robust and effective. Contributions are concluded as well.

  17. Transfer of polarized 3He ions in the AtR beam transfer line

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas N.; MacKay, W.W.; Meot, F.; Roser, T.; Trbojevic, D.

    2012-05-20

    In addition to collisions of electrons with various unpolarized ion species as well as polarized protons, the proposed electron-hadron collider (eRHIC) will facilitate the collisions of electrons with polarized {sup 3}He ions. The AGS is the last acceleration stage, before injection into one of the RHIC's collider ring for final acceleration. The AtR (AGS to RHIC) transfer line will be utilized to transport the polarized {sup 3}He ions from AGS into one of the RHIC's collider rings. Some of the peculiarities of the AtR line's layout (simultaneous horizontal and vertical bends) may degrade the matching of the stable spin direction of the AtR line with that of RHIC's. In this paper we discuss possible simple modifications of the AtR line to accomplish a perfect matching of the stable spin direction of the injected {sup 3}He beam with the stable spin direction at the injection point of RHIC.

  18. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    Science.gov (United States)

    Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Raffaele, L.; Russo, G.; Guatelli, S.; Pia, M. G.

    2006-01-01

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility.

  19. Improved beam extraction for a negative hydrogen ion source for the LHC injector chain upgrade, Linac4

    CERN Document Server

    Midttun, Øystein; Scrivens, Richard

    In the scope of an upgrade of the injector chain of CERN’s accelerator complex, a new linear accelerator, Linac4, is under construction. This accelerator will replace the existing 50 MeV proton linac, Linac2. By increasing the beam energy to 160 MeV, Linac4 makes it possible to double the brightness in the PSB, and ultimately increase the luminosity in the LHC. Linac4 will accelerate beams of negative hydrogen (H-) to be injected into the PSB by multi-turn, charge exchange injection. The ion source was initially based on the non-caesiated RF-volume source from DESY. However, the beam extraction from this source could not handle the 45 keV beam energy required by the RFQ. A new beam extraction system has therefore been designed, via IBSimu simulations [1], to extract and transport the H- ion beam respecting the Linac4 requirements. Key features of the extraction system is a tuneable puller voltage to adapt the extraction field to the ion and electron beam currents, and a magnetized Einzel lens to dump the co...

  20. Maxillary sinus pneumatization after maxillary molar extraction assessed with cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yu Hoa; Nah, Kyung Soo; Cho, Bong Hae [Department of Oral and Maxillofacial Radiology, College of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2009-09-15

    The purpose of this study was to examine the inferior expansion of the maxillary sinus floor following maxillary molar extraction. Cone beam computed tomographic images of 59 subjects were used to evaluate the height difference of the maxillary sinus floor between extraction sites and contralateral dentate sites. The height of the maxillary sinus floor was defined as the vertical distance to the Frankfort plane from the level of the anterior nasal spine to the most inferior point of the sinus floor. We examined the difference in sinus pneumatization according to the number of missing teeth and the vertical relationship of the molar roots to the sinus floor. The inferior expansion of the maxillary sinus floor was 1.20 {+-} 1.86 mm on the maxillary first molar and 1.90 {+-} 2.42 mm on the maxillary second molar. Increased expansion was observed in cases where two proximate molars were extracted. There was no significant difference in sinus pneumatization following extraction according to the vertical relationship of the molar roots to the sinus floor. The results of this study confirm that sinus pneumatization occurs following maxillary molar extraction. In situations where pneumatization can affect treatment after molar extraction, three-dimensional radiography should be considered.

  1. Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, D.; Leitner, D., E-mail: leitnerd@nscl.msu.edu; Cole, D.; Machicoane, G.; Tobos, L. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2014-02-15

    In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

  2. Dual branch high voltage pulse generator for the beam extraction of the Large Hadron Collider

    CERN Document Server

    Bonthond, J; Ducimetière, L; Jansson, U; Vossenberg, Eugène B

    2002-01-01

    The LHC beam extraction kicker system, MKD, is composed of 15 fast kicker magnets per beam to extract the particles in one turn from the collider and to dispose them, after dilution, on an external absorber. Each magnet is powered by a separate pulse generator. The original single branch generator consisted of a discharge capacitor in series with a solid state closing switch left bracket 1 right bracket operating at 30 kV. In combination with a parallel freewheel diode stack this generator produced a current pulse of 2.7 mus rise time, 18.5 kA amplitude and about 1.8 ms fall time, of which only about 90 mus are needed to dump the beam. The freewheel diode circuit is equipped with a flat top current droop compensation network, consisting of a low voltage, low stray inductance, high current discharge capacitor. Extensive reliability studies have meanwhile suggested to further increase the operational safety of this crucial system by equipping each generator with two parallel branches. This paper presents the re...

  3. Cytotoxicity of methanol extracts of Elaeis guineensis on MCF-7 and Vero cell lines

    Institute of Scientific and Technical Information of China (English)

    Soundararajan Vijayarathna; Sreenivasan Sasidharan

    2012-01-01

    To investigate the cytotoxic effect of Elaeis guineensis methanol extract on MCF-7 and Vero cell. Methods: In vitro cytotoxicity was evaluated in by MTT assay. Cell morphological changes were observed by using light microscope. Results: The MTT assay indicated that methanol extract of the plant exhibited significant cytotoxic effects on MCF-7. Morphological alteration of the cell lines after exposure with Elaeis guineensis extract were observed under phase contrast microscope in the dose dependent manner. Conclusions: The results suggest the probable use of the Elaeis guineensis methanol extract in preparing recipes for cancer-related ailments. Further studies on isolation of metabolites and their in vivo cytotoxicity are under investigation.

  4. Cytotoxicity of methanol extracts of Elaeis guineensis on MCF-7 and Vero cell lines.

    Science.gov (United States)

    Vijayarathna, Soundararajan; Sasidharan, Sreenivasan

    2012-10-01

    To investigate the cytotoxic effect of Elaeis guineensis methanol extract on MCF-7 and Vero cell. In vitro cytotoxicity was evaluated in by MTT assay. Cell morphological changes were observed by using light microscope. The MTT assay indicated that methanol extract of the plant exhibited significant cytotoxic effects on MCF-7. Morphological alteration of the cell lines after exposure with Elaeis guineensis extract were observed under phase contrast microscope in the dose dependent manner. The results suggest the probable use of the Elaeis guineensis methanol extract in preparing recipes for cancer-related ailments. Further studies on isolation of metabolites and their in vivo cytotoxicity are under investigation.

  5. IDENTIFIKASI PROFIL DASAR LAUT MENGGUNAKAN INSTRUMEN SIDE SCAN SONAR DENGAN METODE BEAM PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY

    Directory of Open Access Journals (Sweden)

    Muhammad Zainuddin Lubis

    2017-05-01

    Full Text Available Laut Punggur merupakan laut yang terletak di Batam, Kepulauan Riau yang mempunyai beragam habitat objek,dan bentuk struktur bawah laut yang memiliki dinamika laut yang sangat tinggi. Side scan sonar (SSS merupakan instrumen pengembangan sistem sonar yang mampu menunjukkan dalam gambar dua dimensional permukaan dasar laut dengan kondisi kontur, topografi, dan target secara bersamaan. Metode Beam Pattern Discrete-Equi-Spaced Unshaded Line Array digunakan untuk menghitung beam pattern dua dimensi yang tergantung pada sudut dari gelombang suara yang masuk dari sumbu array yang diterima tergantung pada sudut di mana sinar suara pada array. Penelitian ini dilakukan pada Desember 2016 di laut Punggur,Batam, Kepulauan Riau-Indonesia, dengan koordinat 104 ° 08,7102 E dan 1° 03,2448 N sampai 1 ° 03.3977 N dan 104 ° 08,8133 E, menggunakan instrumen Side Scan Sonar C-Max CM2 Tow fish dengan frekuensi 325 kHz. Hasil yang diperoleh dari perekaman terdapat 7 target, dan Beam pattern dari metode Beam Discrete-Equi-Spaced Unshaded Line Array target 4 memiliki nilai tertinggi pada directivity Pattern yaitu 21.08 dB. Hasil model beam pattern ini memiliki nilai pusat pada incidence angle (o terhadap Directivity pattern (dB tidak berada di nilai 0 ataupun pada pusat beam pattern yang dihasilkan pada target 6 dengan nilai incident angle -1.5 o dan 1.5o mengalami penurunan hingga -40 dB. Karakteristik sedimen dasar perairan di laut punggur ditemukan lebih banyak pasir. Hasil metode Beam Discrete-Equi-Spaced Unshaded Line Array ditemukan bangkai kapal tenggelam.Kata Kunci: Side Scan Sonar, Beam Pattern Discrete-Equi-Spaced Unshaded Line Array, Incidence angle, Directivity pattern IDENTIFICATION OF SEABED PROFILE USING SIDE SCAN SONAR INSTRUMENT WITH PATTERN DISCRETE-EQUI-SPACED UNSHADED LINE ARRAY METHODRiau Islands is an island that has a variety of habitat objects, and forms of submarine structures that have a very high ocean dynamics, Punggur Sea is the sea

  6. Source and Extraction for Simultaneous Four-hall Beam Delivery System at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Kazimi, Reza; Wang, Haipeng; Spata, Mike F.; Hansknecht, John C.

    2013-06-01

    A new design for simultaneous delivery of the electron beam to all four 12 GeV CEBAF experimental halls* requires a new 750 MHz RF separator system in the 5th pass extraction region, a 250 MHz repetition rate for its beams, and addition of a fourth laser at the photo-cathode gun. The proposed system works in tandem with the existing 500 MHz RF separators and beam repetition rate on the lower passes. The new 5th pass RF separators will have the same basic design but modified to run at 750 MHz. The change to the beam repetition rate will be at the photo-cathode gun through an innovative upgrade of the seed laser driver system using electro-optic modulators. The new laser system also allows addition of the fourth laser. The new RF separators, the new laser system and other hardware changes required to implement the Four-Hall operation delivery system will be discussed in this paper.

  7. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    Science.gov (United States)

    Liu, S.; Bogard, F.; Cornebise, P.; Faus-Golfe, A.; Fuster-Martínez, N.; Griesmayer, E.; Guler, H.; Kubytskyi, V.; Sylvia, C.; Tauchi, T.; Terunuma, N.; Bambade, P.

    2016-10-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of ∼106 has been successfully demonstrated and confirmed for the first time in simultaneous beam core (∼109 electrons) and beam halo (∼103 electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of diamond sensors using an α source, as well as using the electron beams at PHIL, a low energy < 5 MeV photo-injector at LAL, and at ATF2. First beam halo measurement results using the DSv at ATF2 with different beam intensities and vacuum levels are also presented. Such measurements not only allow one to evaluate the different sources of beam halo generation but also to define the requirements for a suitable collimation system to be installed at ATF2, as well as to optimize its performance during future operation.

  8. Design and fabrication of soft x-ray photolithography experimental beam line at Beijing National Synchrotron Radiation Laboratory

    Science.gov (United States)

    Zhou, Changxin

    1991-08-01

    The synchrotron radiation (SR) soft x-ray photolithography experimental beam line (3B1 beam line) at Beijing National Synchrotron Radiation Laboratory, was completed and tested in June 1990. A soft x-ray photolithography experiment was successfully completed, and the width of linear etch on a silicon chip by the device with a 3B1 beam line is up to 0.5 micrometers . This SR soft x-ray photolithography experiment was done successfully for the first time in China. This paper describes the design of the beam line and the fabrication of the most important optical element--the cylindrical scanning mirror in the beam line. The 3B1 beam line consists of the shielding light plate with water-cooling, laser simulation light source system, 3-D adjustable scanning mirror, high pass-band filer (beryllium window), acoustic sensor, helium gas chamber, and vacuum system. The main specifications of the 3B1 beam line are as follows: spectral range 0.4-2 nm; horizontal acceptance angle 7.5 mrad; vertical acceptance angle 0.4 mrad; grazing incidence angle 1.5 deg; light spot size 35 nm X 12 nm; vacuum degree of the mirror box 5 X 10-10 torr (static). The cylindrical scanning mirror in grazing incidence is used in the beam line for photolithography to obtain uniform distributed intensity of illumination of the SR source in the vertical direction (Gaussian distribution) and sufficiently concentrated energy. It is made of aluminum alloy LD2 with a supersmooth optical surface. The curvature radius of the cylindrical surface is 527.5 mm; surface figure error is less than (lambda) /10; surface roughness is better than 1 nm RMS, and fold coating on the surface of the mirror under UHV of 109 torr. The laser simulation light source system is used for adjusting the optical system in the beam line instead of the SR source. The cylindrical mirror was polished supersmoothly using Al2O3 ultra micropower grinding material made in TOMAS in Japan on modified traditional machine tools, and surface

  9. Bi-spectral beam extraction in combination with a focusing feeder

    CERN Document Server

    Zendler, C; Nekrassov, D; Cussen, L D; Strobl, M

    2013-01-01

    Bi-spectral beam extraction combines neutrons from two different kind of moderators into one beamline, expanding the spectral range and thereby the utilization of an instrument. This idea can be realized by a mirror that reflects long wavelength neutrons from an off-axis colder moderator into a neutron guide aligned with another moderator emitting neutrons with shorter wavelengths which will be transmitted through the mirror. The mirror used in such systems is typically several meters long, which is a severe disadvantage because it reduces the possible length of a focusing device in design concepts requiring a narrow beam at a short distance from the source, as used in many instruments under development for the planned European Spallation Source (ESS). We propose a shortened extraction system consisting of several mirrors, and show that such an extraction system is better suited for combination with a feeder in an eye of the needle design, illustrated here in the context of a possible ESS imaging beamline.

  10. Cytotoxicity screening of Melastoma malabathricum extracts on human breast cancer cell lines in vitro

    Institute of Scientific and Technical Information of China (English)

    Nurfariza; Ahmad; Roslen; Nur; Aizura; Mat; Alewi; Hadji; Ahamada; Mohammad; Syaiful; Bahari; Abdull; Rasad

    2014-01-01

    Objective:To screen the cytotoxic activity of Melasloma malabathricum(M,malubathricum)against human breast carreer cell line(MCF-7)in vitro.Methods:A three steps extraction protocol using n-hexane,chloroform and methanol as the solvents systems was carried out on leaves,stems and flowers of M.nalabathricum.Dimethyl sulfoxide was used in extracts dilution and serial dilutions were conducted to obtain five different extract concentrations(100μg/mL,50μg/mL,25μg/mL,123μg/rnL and 6.25μg/mL).The evaluation of cell growth was determined using methylene blue assay.Results:Methanol extract from the leaves showed significant anticancer activity against MCF-7cell lines with the TC50value of 7.14μg/ml while methanol and chloroform extract from the flowers exhibited a moderate activity towards MCF-7 cell line,with the IC50value of 33.63μg/mL and 45.76μg/mL respectively after 72 h of treatment.Conclusions:The extracts from leaves and flowers of M.nulabatkricum showed promising anticancer activity toward human breast cancer cell lines with the lowest IC50at 7.14μg/mL while the extracts from stems showed less growth inhibition activity.

  11. Ethanolic Extract Cytotoxic Effect of Zingiber Afficinale in Breast Cancer (MCF7 Cell Line

    Directory of Open Access Journals (Sweden)

    J Tavakkol Afshari

    2010-07-01

    Full Text Available Introduction & Objective: Biological activities of Zingiber afficieale plants have been reported as possessing anticancer, antibacterial, anti ulcer, antifungal, and insecticidal properties. However, its antitumor effects haven't been studied in cancer cell lines. The aim of this study was to investigate the antitumor effect of zingiber afficieale on breast cancer cell lines. Materials & Methods: This experimental study was conducted in 2010 at Mashhad University of medical Sciences. Breast cancer cell line (MCF7 and normal connective tissue cell line (L929 were cultured in DMEM medium. Ethanolic extract of Zingiber afficinale was prepared and cell lines were treated with different concentration of extract (5000 to 78 µg. Cell viability was measured by MTT assay after 24, 48, and 72 hours. The collected data were statistically analyzed by SPSS software. Results: The effects of Zingiber afficinale on cell viability were observed after 48 hours on cell lines. Ginger doses in 2500 µg concentration inhibited 50% of cell growth (IC50 in cell lines after 48 hours. Conclusion: Our study revealed that fresh ginger extract has cytotoxic effects on tumor cells, but it doesn’t have any cytotoxic effect on normal cells. It seems that ginger could be considered as a promising chemotherapeutic agent in cancer treatment.

  12. Bunch Length along the Batch of the LHC Beam at Extraction from the PS

    CERN Document Server

    Damerau, H

    2008-01-01

    During machine development experiments with multi-bunch LHC beams in the PS, it has been observed that the bunch length at extraction increases slightly towards the end of the batch. This effect does not only get stronger with increasing intensity, but it is also strongly amplified when instead of the usual two all three 80 MHz cavities are operated to produce bunches significantly shorter than nominal. Systematic measurements show that the bunch length gradient along the batch can be attributed to the effect of the impedance of the 80 MHz cavities.

  13. Scan Line Based Road Marking Extraction from Mobile LiDAR Point Clouds.

    Science.gov (United States)

    Yan, Li; Liu, Hua; Tan, Junxiang; Li, Zan; Xie, Hong; Chen, Changjun

    2016-06-17

    Mobile Mapping Technology (MMT) is one of the most important 3D spatial data acquisition technologies. The state-of-the-art mobile mapping systems, equipped with laser scanners and named Mobile LiDAR Scanning (MLS) systems, have been widely used in a variety of areas, especially in road mapping and road inventory. With the commercialization of Advanced Driving Assistance Systems (ADASs) and self-driving technology, there will be a great demand for lane-level detailed 3D maps, and MLS is the most promising technology to generate such lane-level detailed 3D maps. Road markings and road edges are necessary information in creating such lane-level detailed 3D maps. This paper proposes a scan line based method to extract road markings from mobile LiDAR point clouds in three steps: (1) preprocessing; (2) road points extraction; (3) road markings extraction and refinement. In preprocessing step, the isolated LiDAR points in the air are removed from the LiDAR point clouds and the point clouds are organized into scan lines. In the road points extraction step, seed road points are first extracted by Height Difference (HD) between trajectory data and road surface, then full road points are extracted from the point clouds by moving least squares line fitting. In the road markings extraction and refinement step, the intensity values of road points in a scan line are first smoothed by a dynamic window median filter to suppress intensity noises, then road markings are extracted by Edge Detection and Edge Constraint (EDEC) method, and the Fake Road Marking Points (FRMPs) are eliminated from the detected road markings by segment and dimensionality feature-based refinement. The performance of the proposed method is evaluated by three data samples and the experiment results indicate that road points are well extracted from MLS data and road markings are well extracted from road points by the applied method. A quantitative study shows that the proposed method achieves an average

  14. Scan Line Based Road Marking Extraction from Mobile LiDAR Point Clouds†

    Science.gov (United States)

    Yan, Li; Liu, Hua; Tan, Junxiang; Li, Zan; Xie, Hong; Chen, Changjun

    2016-01-01

    Mobile Mapping Technology (MMT) is one of the most important 3D spatial data acquisition technologies. The state-of-the-art mobile mapping systems, equipped with laser scanners and named Mobile LiDAR Scanning (MLS) systems, have been widely used in a variety of areas, especially in road mapping and road inventory. With the commercialization of Advanced Driving Assistance Systems (ADASs) and self-driving technology, there will be a great demand for lane-level detailed 3D maps, and MLS is the most promising technology to generate such lane-level detailed 3D maps. Road markings and road edges are necessary information in creating such lane-level detailed 3D maps. This paper proposes a scan line based method to extract road markings from mobile LiDAR point clouds in three steps: (1) preprocessing; (2) road points extraction; (3) road markings extraction and refinement. In preprocessing step, the isolated LiDAR points in the air are removed from the LiDAR point clouds and the point clouds are organized into scan lines. In the road points extraction step, seed road points are first extracted by Height Difference (HD) between trajectory data and road surface, then full road points are extracted from the point clouds by moving least squares line fitting. In the road markings extraction and refinement step, the intensity values of road points in a scan line are first smoothed by a dynamic window median filter to suppress intensity noises, then road markings are extracted by Edge Detection and Edge Constraint (EDEC) method, and the Fake Road Marking Points (FRMPs) are eliminated from the detected road markings by segment and dimensionality feature-based refinement. The performance of the proposed method is evaluated by three data samples and the experiment results indicate that road points are well extracted from MLS data and road markings are well extracted from road points by the applied method. A quantitative study shows that the proposed method achieves an average

  15. Multiobjective optimization design of an rf gun based electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan; Maxson, Jared

    2017-03-01

    Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100 MV /m 1.6-cell normal conducting rf (NCRF) gun, as well as a nine-cell 2 π /3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 1 06 electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 1 06 electrons and final beam sizes of σx≥25 μ m and σt≈5 fs , we found a relative coherence length of Lc ,x/σx≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2 nm /μ m , respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 1 05 electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92 nm /μ m for final bunch lengths of 5, 30 and 100 fs, respectively.

  16. Cytotoxic effect of Argentine medicinal plant extracts on human hepatocellular carcinoma cell line.

    Science.gov (United States)

    Ruffa, M J; Ferraro, G; Wagner, M L; Calcagno, M L; Campos, R H; Cavallaro, L

    2002-03-01

    Methanolic extracts from Achyrocline satureioides (Dc.) Lam, Aristolochia macroura Gomez, Lithraea molleoides (Vell.) Engl., Schinus molle L., unlike those from Celtis spinosa Spreng, Chenopodium ambrosioides L., Petiveria alliacea L., and Plantago major L. showed cytotoxic activity against a human hepatocellular carcinoma cell line, Hep G2. Schinus molle L. was the most active (IC50=50+/-7 microg/ml). These results call for further studies of these extracts.

  17. Clinacanthus nutans Extracts Are Antioxidant with Antiproliferative Effect on Cultured Human Cancer Cell Lines

    Directory of Open Access Journals (Sweden)

    Yoke Keong Yong

    2013-01-01

    Full Text Available Clinacanthus nutans Lindau leaves (CN have been used in traditional medicine but the therapeutic potential has not been explored for cancer prevention and treatment. Current study aimed to evaluate the antioxidant and antiproliferative effects of CN, extracted in chloroform, methanol, and water, on cancer cell lines. Antioxidant properties of CN were evaluated using DPPH, galvinoxyl, nitric oxide, and hydrogen peroxide based radical scavenging assays, whereas the tumoricidal effect was tested on HepG2, IMR32, NCL-H23, SNU-1, Hela, LS-174T, K562, Raji, and IMR32 cancer cells using MTT assay. Our data showed that CN in chloroform extract was a good antioxidant against DPPH and galvinoxyl radicals, but less effective in negating nitric oxide and hydrogen peroxide radicals. Chloroform extract exerted the highest antiproliferative effect on K-562 (91.28±0.03% and Raji cell lines (88.97±1.07% at 100 μg/ml and the other five cancer cell lines in a concentration-dependent manner, but not on IMR-32 cells. Fourteen known compounds were identified in chloroform extract, which was analysed by gas chromatography—mass spectra analysis. In conclusion, CN extracts possess antioxidant and antiproliferative properties against cultured cancer cell lines, suggesting an alternate adjunctive regimen for cancer prevention or treatment.

  18. Clinacanthus nutans Extracts Are Antioxidant with Antiproliferative Effect on Cultured Human Cancer Cell Lines.

    Science.gov (United States)

    Yong, Yoke Keong; Tan, Jun Jie; Teh, Soek Sin; Mah, Siau Hui; Ee, Gwendoline Cheng Lian; Chiong, Hoe Siong; Ahmad, Zuraini

    2013-01-01

    Clinacanthus nutans Lindau leaves (CN) have been used in traditional medicine but the therapeutic potential has not been explored for cancer prevention and treatment. Current study aimed to evaluate the antioxidant and antiproliferative effects of CN, extracted in chloroform, methanol, and water, on cancer cell lines. Antioxidant properties of CN were evaluated using DPPH, galvinoxyl, nitric oxide, and hydrogen peroxide based radical scavenging assays, whereas the tumoricidal effect was tested on HepG2, IMR32, NCL-H23, SNU-1, Hela, LS-174T, K562, Raji, and IMR32 cancer cells using MTT assay. Our data showed that CN in chloroform extract was a good antioxidant against DPPH and galvinoxyl radicals, but less effective in negating nitric oxide and hydrogen peroxide radicals. Chloroform extract exerted the highest antiproliferative effect on K-562 (91.28 ± 0.03%) and Raji cell lines (88.97 ± 1.07%) at 100  μ g/ml and the other five cancer cell lines in a concentration-dependent manner, but not on IMR-32 cells. Fourteen known compounds were identified in chloroform extract, which was analysed by gas chromatography-mass spectra analysis. In conclusion, CN extracts possess antioxidant and antiproliferative properties against cultured cancer cell lines, suggesting an alternate adjunctive regimen for cancer prevention or treatment.

  19. Development of a polarized neutron beam line at Algerian research reactors using McStas software

    Science.gov (United States)

    Makhloufi, M.; Salah, H.

    2017-02-01

    Unpolarized instrumentation has long been studied and designed using McStas simulation tool. But, only recently new models were developed for McStas to simulate polarized neutron scattering instruments. In the present contribution, we used McStas software to design a polarized neutron beam line, taking advantage of the available spectrometers reflectometer and diffractometer in Algeria. Both thermal and cold neutron was considered. The polarization was made by two types of supermirrors polarizers FeSi and CoCu provided by the HZB institute. For sake of performance and comparison, the polarizers were characterized and their characteristics reproduced. The simulated instruments are reported. Flipper and electromagnets for guide field are developed. Further developments including analyzers and upgrading of the existing spectrometers are underway.

  20. Compact intra-cavity frequency doubled line beam green laser by a laser diode array pumped

    Science.gov (United States)

    Yan, Boxia; Qi, Yan; Wang, Yanwei

    2016-10-01

    Compact, high power, and low-cost green laser light sources are needed in projection-related applications such as digital cinema, rear-projection television, simulators, and command and control stations. We report a LD array directly pumped intracavity SHG Nd:YVO4/PPMgLN laser without lens or waveguide in this letter. A compact 3.12 W green laser was demonstrated by intra-cavity frequency doubled using a PPMgLN bulk crystal by a 19-emitter LD array pumped(single bar), the conversion efficiency from input LD array was 9.2%. A line-beam output suitable for laser projectors was generated, which has the potential to be scalable to small volumes and low costs for laser projection displays.

  1. Generation of a twin beam at the cesium line and telecom wavelength by cavity phase matching.

    Science.gov (United States)

    Liu, Y H; Xie, Z D; Ling, W; Lv, X J; Zhu, S N

    2011-08-15

    Cavity phase matching has been recently demonstrated as a phase-matching method for efficient nonlinear frequency conversion in a microcavity. Here we extend it to the Type I configuration using a sub-coherent-length optical parametric oscillator consisting of an MgO-doped lithium niobate crystal sheet. It generates a tunable single-longitudinal-mode twin beam, which covers the cesium D2 line of 852.1 nm and the extended band of optical communication. This microcavity is capable of peak output power of 58 kW with a maximum conversion efficiency of 18.5%. Broad applications in the areas of light-atom interaction, spectroscopy, optical telecommunication, and quantum optics can be expected.

  2. High power microwave beam steering based on gyromagnetic nonlinear transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Romanchenko, I. V., E-mail: riv@lfe.hcei.tsc.ru; Rostov, V. V.; Gunin, A. V.; Konev, V. Yu. [Institute of high current electronics SB RAS, Akademichesky 2/3, 634055, Tomsk (Russian Federation)

    2015-06-07

    We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

  3. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Liu, Shan; Cornebise, Patrick; Faus-Golfe, Angeles; Fuster-Martínez, Nuria; Griesmayer, Erich; Guler, Hayg; Kubytskyi, Viacheslav; Sylvia, Christophe; Toshiaki, Tauchi; Terunuma, Nobuhiro; Bambade, Philip

    2015-01-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of $\\sim10^6$ has been successfully demonstrated and confirmed for the first time by simultaneous beam core ($\\sim10^9$ electrons) and beam halo ($\\sim10^3$ electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of the diamond sensors using an $\\alpha$ source as well as using the electron beams at PHIL, a low energy ($< 10$ MeV) photo-injector at LAL, and at ATF2. First beam halo measurement results ...

  4. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  5. RAPD and SSR Polymorphisms in Mutant Lines of Transgenic Wheat Mediated by Low Energy Ion Beam

    Institute of Scientific and Technical Information of China (English)

    WANG Tiegu; HUANG Qunce; FENG Weisen

    2007-01-01

    Two types of markers-random amplified polymorphic DNA (RAPD) and simple sequence repeat DNA (SSR)-have been used to characterize the genetic diversity among nine mutant lines of transgenic wheat intermediated by low energy ion beam and their four receptor cultivars. The objectives of this study were to analyze RAPD-based and SSR-based genetic variance among transgenic wheat lines and with their receptors, and to find specific genetic markers of special traits of transgenic wheat lines. 170 RAPD primers were amplified to 733 fragments in all the experimental materials. There were 121 polymorphic fragments out of the 733 fragments with a ratio of polymorphic fragments of 16.5%. 29 SSR primer pairs were amplified to 83 fragments in all the experiment materials. There were 57 polymorphic fragments out of the 83 fragments with a ratio of polymorphic fragments of 68.7%. The dendrograms were prepared based on a genetic distance matrix using the UPGMA (Unweighted Pair-group Method with Arithmetic averaging) algorithm, which corresponded well to the results of the wheat pedigree analysis and separated the 13 genotypes into four groups. Association analysis between RAPD and SSR markers with the special traits of transgenic wheat mutant lines discovered that three RAPD markers, si, opt-16, and fl4, were significantly associated with the muticate trait, while three SSR markers, Rht8 (Xgwm261), Rht-Blb, and Rht-Dlb, highly associated with the dwarf trait. These markers will be useful for marker-assistant breeding and can be used as candidate markers for further gene mapping and cloning.

  6. Radiation-hard Beam Position Detector for Use in the Accelerator Dump Lines

    CERN Document Server

    Degtiarenko, Pavel; Popov, Vladimir

    2005-01-01

    Proper transport of the electron beam with over 0.5MW of power to the beam dump is a prerequisite for operations at Jefferson Lab. Operations has relied on imaging the beam on a beam viewer located at the entrance to the beam dump. The large beam size at the dump entrance, due to beam scattering in the experimental target, sometimes results in no observable image on the view-screen. Chemical vapor deposited silicon carbide (CVD) material with its large thermal conductivity and high melting point is well suited for surviving the thermal effects of beam exposure with this power density. We are exploring the CVD properties and how it can be used as a robust beam position monitor. Results of some beam tests with 0.5MW beams will be presented.

  7. Beam diagnostics, collimation, injection/extraction, targetry, accidents and commissioning: Working group C&G summary report

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N.V.; /Fermilab; Hasegawa, K.; /JAEA, Ibaraki; Henderson, S.; /Oak Ridge; Schmidt, R.; /CERN; Tomizawa, M.; /KEK, Tsukuba; Wittenburg, K.; /DESY

    2006-11-01

    The performance of accelerators with high beam power or high stored beam energy is strongly dependent on the way the beam is handled, how beam parameters are measured and how the machine is commissioned. Two corresponding working groups have been organized for the Workshop: group C ''Beam diagnostics, collimation, injection/extraction and targetry'' and group G ''Commissioning strategies and procedures''. It has been realized that the issues to be discussed in these groups are interlaced with the participants involved and interested in the above topics, with an extremely important subject of beam-induced accidents as additional topic. Therefore, we have decided to combine the group sessions as well as this summary report. Status, performance and outstanding issues of each the topic are described in the sections below, with additional observations and proposals by the joint group at the end.

  8. Beam diagnostics, collimation, injection/extraction, targetry, accidents and commissioning: Working group C&G summary report

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N.V.; /Fermilab; Hasegawa, K.; /JAEA, Ibaraki; Henderson, S.; /Oak Ridge; Schmidt, R.; /CERN; Tomizawa, M.; /KEK, Tsukuba; Wittenburg, K.; /DESY

    2006-11-01

    The performance of accelerators with high beam power or high stored beam energy is strongly dependent on the way the beam is handled, how beam parameters are measured and how the machine is commissioned. Two corresponding working groups have been organized for the Workshop: group C ''Beam diagnostics, collimation, injection/extraction and targetry'' and group G ''Commissioning strategies and procedures''. It has been realized that the issues to be discussed in these groups are interlaced with the participants involved and interested in the above topics, with an extremely important subject of beam-induced accidents as additional topic. Therefore, we have decided to combine the group sessions as well as this summary report. Status, performance and outstanding issues of each the topic are described in the sections below, with additional observations and proposals by the joint group at the end.

  9. Anticancer Effects of Extracts from the Fruit of Morinda Citrifolia (Noni) in Breast Cancer Cell Lines.

    Science.gov (United States)

    Sharma, K; Pachauri, S D; Khandelwal, K; Ahmad, H; Arya, A; Biala, P; Agrawal, S; Pandey, R R; Srivastava, A; Srivastav, A; Saxena, J K; Dwivedi, A K

    2016-03-01

    Morinda citrifolia L. (NONI) fruits have been used for thousands of years for the treatment of many health problems including cancer, cold, diabetes, flu, hypertension, and pain. Plant extracts have reported several therapeutic benefits, but extraction of individual compound from the extract often exhibits limited clinical utility as the synergistic effect of various natural ingredients gets lost. They generally constitute polyphenols and flavonoids. Studies have suggested that these phytochemicals, especially polyphenols, display high antioxidant properties, which help to reduce the risk of degenerative diseases, such as cancer and cardiovascular diseases. Several in-vitro and in-vivo studies have shown that Noni fruits have antioxidant, anti-inflammatory, anti-dementia, liver-protective, anticancer, analgesic, and immunomodulatory effects. Till date about 7 in vitro cancer studies have been done, but a detailed in vitro study including cell cycle and caspase activation assay on breast cancer cell line has not been done. In the present study different Noni fruit fractions have tested on cancer cell lines MCF-7, MDA-MB-231 (breast adenocarcinoma) and one non-cancer cell line HEK-293 (Human embryonic kidney). Out of which ethylacetate extract showed a higher order of in vitro anticancer activity profile. The ethylacetate extract strongly inhibited the proliferation of MCF-7, MDA-MB-231 and HEK-293 cell lines with IC50 values of 25, 35, 60 µg/ml respectively. The extract showed increase in apoptotic cells in MCF-7 and MDA-MB-231 cells and arrested the cell cycle in the G1/S phase in MCF-7 and G0/G1 phase in MDA-MB-231 cells. Noni extract also decreases the intracellular ROS generation and mitochondrial membrane potential.

  10. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Bellodi, G; Dimov, V; Küchler, D; Lombardi, A M; Maintrot, M

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  11. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Science.gov (United States)

    Toivanen, V.; Bellodi, G.; Dimov, V.; Küchler, D.; Lombardi, A. M.; Maintrot, M.

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  12. Space Charge Compensation in the Linac4 Low Energy Beam Transport Line with Negative Hydrogen Ions

    CERN Document Server

    Valerio-Lizarraga, C; Leon-Monzon, I; Lettry, J; Midttun, O; Scrivens, R

    2014-01-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Tranport (LEBT) using the package IBSimu1, which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H- beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  13. Automatic Extraction of Tunnel Lining Cross-Sections from Terrestrial Laser Scanning Point Clouds

    Directory of Open Access Journals (Sweden)

    Yun-Jian Cheng

    2016-10-01

    Full Text Available Tunnel lining (bare-lining cross-sections play an important role in analyzing deformations of tunnel linings. The goal of this paper is to develop an automatic method for extracting bare-lining cross-sections from terrestrial laser scanning (TLS point clouds. First, the combination of a 2D projection strategy and angle criterion is used for tunnel boundary point detection, from which we estimate the two boundary lines in the X-Y plane. The initial direction of the cross-sectional plane is defined to be orthogonal to one of the two boundary lines. In order to compute the final cross-sectional plane, the direction is adjusted twice with the total least squares method and Rodrigues' rotation formula, respectively. The projection of nearby points is made onto the adjusted plane to generate tunnel cross-sections. Finally, we present a filtering algorithm (similar to the idea of the morphological erosion to remove the non-lining points in the cross-section. The proposed method was implemented on railway tunnel data collected in Sichuan, China. Compared with an existing method of cross-sectional extraction, the proposed method can offer high accuracy and more reliable cross-sectional modeling. We also evaluated Type I and Type II errors of the proposed filter, at the same time, which gave suggestions on the parameter selection of the filter.

  14. Extracting potential bus lines of Customized City Bus Service based on public transport big data

    Science.gov (United States)

    Ren, Yibin; Chen, Ge; Han, Yong; Zheng, Huangcheng

    2016-11-01

    Customized City Bus Service (CCBS) can reduce the traffic congestion and environmental pollution that caused by the increasing in private cars, effectively. This study aims to extract the potential bus lines and each line's passenger density of CCBS by mining the public transport big data. The datasets used in this study are mainly Smart Card Data (SCD) and bus GPS data of Qingdao, China, from October 11th and November 7th 2015. Firstly, we compute the temporal-origin-destination (TOD) of passengers by mining SCD and bus GPS data. Compared with the traditional OD, TOD not only has the spatial location, but also contains the trip's boarding time. Secondly, based on the traditional DBSCAN algorithm, we put forwards an algorithm, named TOD-DBSCAN, combined with the spatial-temporal features of TOD.TOD-DBSCAN is used to cluster the TOD trajectories in peak hours of all working days. Then, we define two variables P and N to describe the possibility and passenger destiny of a potential CCBS line. P is the probability of the CCBS line. And N represents the potential passenger destiny of the line. Lastly, we visualize the potential CCBS lines extracted by our procedure on the map and analyse relationship between potential CCBS lines and the urban spatial structure.

  15. Automatic Extraction of Tunnel Lining Cross-Sections from Terrestrial Laser Scanning Point Clouds.

    Science.gov (United States)

    Cheng, Yun-Jian; Qiu, Wenge; Lei, Jin

    2016-10-06

    Tunnel lining (bare-lining) cross-sections play an important role in analyzing deformations of tunnel linings. The goal of this paper is to develop an automatic method for extracting bare-lining cross-sections from terrestrial laser scanning (TLS) point clouds. First, the combination of a 2D projection strategy and angle criterion is used for tunnel boundary point detection, from which we estimate the two boundary lines in the X-Y plane. The initial direction of the cross-sectional plane is defined to be orthogonal to one of the two boundary lines. In order to compute the final cross-sectional plane, the direction is adjusted twice with the total least squares method and Rodrigues' rotation formula, respectively. The projection of nearby points is made onto the adjusted plane to generate tunnel cross-sections. Finally, we present a filtering algorithm (similar to the idea of the morphological erosion) to remove the non-lining points in the cross-section. The proposed method was implemented on railway tunnel data collected in Sichuan, China. Compared with an existing method of cross-sectional extraction, the proposed method can offer high accuracy and more reliable cross-sectional modeling. We also evaluated Type I and Type II errors of the proposed filter, at the same time, which gave suggestions on the parameter selection of the filter.

  16. Exploring the Anticancer Activity of Grape Seed Extract on Skin Cancer Cell Lines A431

    Directory of Open Access Journals (Sweden)

    V. Mohansrinivasan

    2015-08-01

    Full Text Available In this study, grape seeds were extracted using ethyl acetate and petroleum ether by solvent-solvent extraction method. The phytochemical tests were performed to identify different phytochemical compounds present in the grape seed extract (GSE. Antibacterial activity of the GSE was determined using agar diffusion method against Gram- positive and Gram-negative bacteria. Gas chromatography-mass spectrometry (GC-MS and Fourier transform infrared spectroscopy (FTIR analysis was done to identify the presence of bioactive compounds and their functional groups. The GC-MS results revealed a total of four compounds, known to have potent activity against cancer cells, viz, squalene, the most potent compound found in ethyl acetate extract and diethyl phthalate, ethyl-9- cis -11- trans octadecadienoate and (R-(--14,-methyl-8-Hexadecyn-1-ol in petroleum ether extract. Cytotoxic activity of the GSE was observed against skin cancer cell lines A4321 using 3-(4, 5-dimethylthiazol-2-yl-2-5-diphenyl tetrazolium bromide MTT assay. The IC50 value of the GSE against A431 skin cancer cell line was 480 µg/mL. This is first such report against A4321 cell lines. The study gives the overall perception about importance of GSE in medicine and nutraceuticals purposes.

  17. Cytotoxic activity of kenaf (Hibiscus cannabinus L.) seed extract and oil against human cancer cell lines

    Institute of Scientific and Technical Information of China (English)

    Yu Hua Wong; Wai Yan Tan; Chin Ping Tan; Kamariah Long; Kar Lin Nyam

    2014-01-01

    Objective: To examine the cytotoxic properties of both the kenaf (Hibiscus cannabinus L.) seed extract and kenaf seed oil on human cervical cancer, human breast cancer, human colon cancer and human lung cancer cell lines.Methods:kenaf seed oil on human cancer cell lines was evaluated by using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide and sulforhodamine B assays. Cell morphological changes were observed by using an inverted light microscope.Results:The in vitro cytotoxic activity of the kenaf (Hibiscus cannabinus L.) seed extract and cancer cell lines. Morphological alterations in the cell lines after KSE and KSO treatment were observed. KSE and KSO possessed effective cytotoxic activities against all the cell lines been selected.Conclusions:KSE and KSO could be potential sources of natural anti-cancer agents. Further The kenaf seed extract (KSE) exhibited a lower IC50 than kenaf seed oil (KSO) in all of the investigations on using kenaf seeds for anti-proliferative properties are warranted.

  18. Transverse beam splitting made operational: Recent progress of the multi-turn extraction at the CERN proton synchrotron

    CERN Document Server

    AUTHOR|(CDS)2082016; Borburgh, Jan; Damjanovic, Sanja; Gilardoni, Simone; Giovannozzi, Massimo; Hourican, Michael; Kahle, Karsten; Michels, Olivier; Sterbini, Guido; Hernalsteens, Cedric; Le Godec, Gilles

    2016-01-01

    Following a successful commissioning period, the Multi-Turn Extraction (MTE) at the CERN Proton Synchrotron (PS) has been applied for the fixed-target physics programme at the Super Proton Synchrotron (SPS) since September 2015. This exceptional extraction technique was proposed to replace the long-serving Continuous Transfer (CT) extraction, which has the drawback of inducing high activation in the ring. MTE exploits the principles of non-linear beam dynamics to perform loss-free beam splitting in the horizontal phase space. Over multiple turns, the resulting beamlets are then transferred to the downstream accelerator. The operational deployment of MTE was rendered possible by the full understanding and mitigation of different hardware limitations and by redesigning the extraction trajectories and non-linear optics, which was required due to the installation of a dummy septum to reduce the activation of the magnetic extraction septum. The results of the related experimental and simulation studies, a summary ...

  19. GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

    CERN Multimedia

    2004-01-01

    GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

  20. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10Â MeV

    Science.gov (United States)

    Busold, S.; Schumacher, D.; Deppert, O.; Brabetz, C.; Kroll, F.; Blažević, A.; Bagnoud, V.; Roth, M.

    2014-03-01

    We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 109 particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E0 at FWHM). A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf) field is applied via a rf cavity for energy compression at a synchronous phase of -90 deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  1. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10 MeV

    Directory of Open Access Journals (Sweden)

    S. Busold

    2014-03-01

    Full Text Available We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 10^{9} particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E_{0} at FWHM. A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf field is applied via a rf cavity for energy compression at a synchronous phase of -90  deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  2. Tertiary particle production and target optimization of the H2 beam line in the SPS North Area

    CERN Document Server

    Tellander, Felix

    2016-01-01

    H2 beam line of SPS North Area is a high energy, high resolution and multipurpose particle beam line. It is able to transport secondary hadron and pure electron beams with momenta between 10 and 400 GeV/c to be exploited by several different experiments. In this work, tertiary particle production from a secondary target placed in the line is studied. The introduction of this “filter” target enhances the middle to low momentum hadron (20 - 60 GeV/c) and electron production. In this work, a systematic Monte Carlo simulation study using a GEANT 4 based package, G4beamline, has been performed in order to investigate the tertiary particle production from several different targets. More specifically, Cu, W and polyethylene targets with different thicknesses have been studied. The proton over pi+ ratio is of particular interest, as well as the optimal electron production for several momenta. The present work will act as a reference to be used by the future test-beam users of the line as an indication of the expe...

  3. submitter Light Extraction From Scintillating Crystals Enhanced by Photonic Crystal Structures Patterned by Focused Ion Beam

    CERN Document Server

    Modrzynski, Pawel; Knapitsch, Arno; Kunicki, Piotr; Lecoq, Paul; Moczala, Magdalena; Papakonstantinou, Ioannis; Auffray, Etiennette

    2016-01-01

    “Photonic Crystals (PhC)” have been used in a variety of fields as a structure for improving the light extraction efficiency from materials with high index of refraction. In previous work we already showed the light extraction improvement of several PhC covered LYSO crystals in computer simulations and practical measurements. In this work, new samples are made using different materials and techniques which allows further efficiency improvements. For rapid prototyping of PhC patterns on scintillators we tested a new method using “Focused Ion Beam (FIB)” patterning. The FIB machine is a device similar to a “Scanning Electron Microscope (SEM)”, but it uses ions (mainly gallium) instead of electrons for the imaging of the samples' surface. The additional feature of FIB devices is the option of surface patterning in nano-scale which was exploited for our samples. Three samples using FIB patterning have been produced. One of them is a direct patterning of the extraction face of a 0.8×0.8×10 $mm^3$ LYS...

  4. Extraction of a strongly focusing He+ beam from three-stage concave electrodes for alpha particle measurement system in ITER.

    Science.gov (United States)

    Kobuchi, T; Sasao, M; Kisaki, M; Tsumori, K; Tanaka, N; Okamoto, A; Kitajima, S; Kaneko, O; Shinto, K; Wada, M

    2012-02-01

    A strongly focusing He(+) ion beam source equipped with concave multi-aperture electrodes was developed for production of He(-) through a charge exchange cell. The beam was extracted at a voltage less than 20 kV from 301 apertures distributed in an area of 100 mm φ, and focused at 750 mm distance. The beam current and the beam size of 2 A and 20 mm in diameter, respectively, were achieved with an arc power less than 10 kW. The optimum perveance was obtained at 0.02 A∕kV(1.5) at the beam energy less than 20 keV which is suitable for the conversion to He(-) in an alkali vapor cell.

  5. Cytotoxicity of methanol extracts of Elaeis guineensis on MCF-7 and Vero cell lines

    Institute of Scientific and Technical Information of China (English)

    Soundararajan; Vijayarathna; Sreenivasan; Sasidharan

    2012-01-01

    Objective:To investigate the cytotoxic effect of Elaeis guineensis methanol extract on MCF-7and Vero cell.Methods:In vitro cytotoxicity was evaluated in by MTT assay.Cell morphological changes were observed by using light microscope.Results:The MTT assay indicated that methanol extract of the plant exhibited significant cytotoxic effects on MCF-7.Morphological alteration of the cell lines after exposure with lilaeis guineensis extract were observed under phase contrast microscope in the dose dependent manner.Conclusions:The results suggest the probable use of the Elaeis guineensis methanol extract in preparing recipes for cancer-related ailments.Further studies on isolation of metabolites and their in vivo cytotoxicity are under investigation.

  6. Red grape seed extract and its compound resveratrol exert cytotoxic effect to various human cancer lines.

    Science.gov (United States)

    Şahin, Fahri; Avcı, Çığır Biray; Avcu, Ferit; Ural, Ali Uğur; Sarper, Meral; Hışıl, Yaşar; Omay, Serdar Bedii; Saydam, Güray

    2007-09-05

    Modern medicinal agents currently available for treatment of cancers are very expensive, toxic, and less effective in treating some of the disease. Thus, one must investigate further in detail the agents derived from natural sources, such as grape seed, for the prevention and treatment of cancer and disease. In recent years interest of researchers has focused on grape seed and nowadays scientists have used extracts of grape seed to treat different health problems including cancer. We examined the cytotoxic effect of red grape seed extract (GSE) and its main compound resveratrol (RES) on different human cancer cell lines representing various solid tumors and hematological malignancies at the same time. Red GSE was prepared by using 1, 1, 1, 2- Tetrafluoroethane extraction method. Cytotoxicity of the extract and RES was evaluated by using trypan blue dye exclusion method and MTT assay. The results of our study show that GSE and RES have cytotoxic activities in varying degree in several cancer cell lines. There has not been any study evaluating the GES and RES in the same cell lines and in the same conditions. But, it is still needed to have more pre-clinical and laboratory studies to validate the usefulness of these agents either alone or in combination with existing therapy.

  7. Differential Response of Two Human Breast Cancer Cell Lines to the Phenolic Extract from Flaxseed Oil

    Directory of Open Access Journals (Sweden)

    Angela Sorice

    2016-03-01

    Full Text Available Many studies have evidenced that the phenolic components from flaxseed (FS oil have potential health benefits. The effect of the phenolic extract from FS oil has been evaluated on two human breast cancer cell lines, MCF7 and MDA-MB231, and on the human non-cancerous breast cell line, MCF10A, by SRB assay, cellular death, cell cycle, cell signaling, lipid peroxidation and expression of some key genes. We have evidenced that the extract shows anti-proliferative activity on MCF7 cells by inducing cellular apoptosis, increase of the percentage of cells in G0/G1 phase and of lipid peroxidation, activation of the H2AX signaling pathway, and upregulation of a six gene signature. On the other hand, on the MDA-MB2131 cells we verified only an anti-proliferative activity, a weak lipid peroxidation, the activation of the PI3K signaling pathway and an up-regulation of four genes. Overall these data suggest that the extract has both cytotoxic and pro-oxidant effects only on MCF7 cells, and can act as a metabolic probe, inducing differences in the gene expression. For this purpose, we have performed an interactomic analysis, highlighting the existing associations. From this approach, we show that the phenotypic difference between the two cell lines can be explained through their differential response to the phenolic extract.

  8. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Science.gov (United States)

    Viezzer, E.; Dux, R.; Dunne, M. G.

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  9. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade.

    Science.gov (United States)

    Viezzer, E; Dux, R; Dunne, M G

    2016-11-01

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line Dα. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  10. A new beam emission polarimetry diagnostic for measuring the magnetic field line angle at the plasma edge of ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Viezzer, E., E-mail: eleonora.viezzer@ipp.mpg.de, E-mail: eviezzer@us.es [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Department of Atomic, Molecular, and Nuclear Physics, University of Seville, Avda. Reina Mercedes, 41012 Seville (Spain); Dux, R.; Dunne, M. G. [Max-Planck-Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-11-15

    A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D{sub α}. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.

  11. Producing multicharged fullerene ion beam extracted from the second stage of tandem-type ECRIS

    Energy Technology Data Exchange (ETDEWEB)

    Nagaya, Tomoki, E-mail: nagaya@nf.eie.eng.osaka-u.ac.jp; Nishiokada, Takuya; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu; Kato, Yushi [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan); Uchida, Takashi [Graduate School of Interdisciplinary New Science, Toyo University, 2100, Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan); Bio-Nano Electronics Research Centre, Toyo University, 2100, Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan); Muramatsu, Masayuki; Kitagawa, Atsushi [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Yoshida, Yoshikazu [Graduate School of Interdisciplinary New Science, Toyo University, 2100, Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan); Faculty of Science and Engineering, Toyo University, 2100, Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan)

    2016-02-15

    We have been constructing the tandem-type electron cyclotron resonance ion source (ECRIS). Two ion sources of the tandem-type ECRIS are possible to generate plasma individually, and they also confined individual ion species by each different plasma parameter. Hence, it is considered to be suitable for new materials production. As the first step, we try to produce and extract multicharged C{sub 60} ions by supplying pure C{sub 60} vapor in the second stage plasma because our main target is producing the endohedral fullerenes. We developed a new evaporator to supply fullerene vapor, and we succeeded in observation about multicharged C{sub 60} ion beam in tandem-type ECRIS for the first time.

  12. Fast characterization of line-end shortening and application of novel correction algorithms in e-beam direct write

    Science.gov (United States)

    Freitag, Martin; Choi, Kang-Hoon; Gutsch, Manuela; Hohle, Christoph; Galler, Reinhard; Krüger, Michael; Weidenmueller, Ulf

    2011-04-01

    For the manufacturing of semiconductor technologies following the ITRS roadmap, we will face the nodes well below 32nm half pitch in the next 2~3 years. Despite being able to achieve the required resolution, which is now possible with electron beam direct write variable shaped beam (EBDW VSB) equipment and resists, it becomes critical to precisely reproduce dense line space patterns onto a wafer. This exposed pattern must meet the targets from the layout in both dimensions (horizontally and vertically). For instance, the end of a line must be printed in its entire length to allow a later placed contact to be able to land on it. Up to now, the control of printed patterns such as line ends is achieved by a proximity effect correction (PEC) which is mostly based on a dose modulation. This investigation of the line end shortening (LES) includes multiple novel approaches, also containing an additional geometrical correction, to push the limits of the available data preparation algorithms and the measurement. The designed LES test patterns, which aim to characterize the status of LES in a quick and easy way, were exposed and measured at Fraunhofer Center Nanoelectronic Technologies (CNT) using its state of the art electron beam direct writer and CD-SEM. Simulation and exposure results with the novel LES correction algorithms applied to the test pattern and a large production like pattern in the range of our target CDs in dense line space features smaller than 40nm will be shown.

  13. Novel technique for injecting and extracting beams in a circular hadron accelerator without using septum magnets

    Directory of Open Access Journals (Sweden)

    Andrea Franchi

    2015-07-01

    Full Text Available With a few exceptions, all on-axis injection and extraction schemes implemented in circular particle accelerators, synchrotrons, and storage rings, make use of magnetic and electrostatic septa with systems of slow-pulsing dipoles acting on tens of thousands of turns and fast-pulsing dipoles on just a few. The dipoles create a closed orbit deformation around the septa, usually referred to as an orbit bump. A new approach is presented which obviates the need for the septum deflectors. Fast-pulsing elements are still required, but their strength can be minimized by choosing appropriate local accelerator optics. This technique should increase the beam clearance and reduce the usually high radiation levels found around the septa and also reduce the machine impedance introduced by the fast-pulsing dipoles. The basis of the technique is the creation of stable islands around stable fixed points in horizontal phase space. The trajectories of these islands may then be adjusted to match the position and angle of the incoming or outgoing beam.

  14. Antiproliferative activity of methanol extracts of four species of Croton on different human cell lines

    Directory of Open Access Journals (Sweden)

    Jóice P. Savietto

    2013-08-01

    Full Text Available Several species of Croton have been described with biological activities, mainly due to diterpenes, alkaloids and/or other secondary metabolites. These activities account for the traditional use of Croton species to treat certain diseases in South America, Asia and Western Africa. The crude methanol extracts obtained from leaves and steam bark of Croton dichrous Müll. Arg., C. erythroxyloides Baill., C. myrianthus Müll. Arg. and C. splendidus Mart. ex Colla were tested for antiproliferative activity against ten human cancer cell lines. Chemical analyses of all extracts were carried out by GC/MS and HPLC/MS/MS. The leaf extract obtained from C. erythroxyloides showed potent activity against PC-3 (prostate and OVCAR-3 (ovary cell lines. Lupeol is suggested to be involved in such activity. Tiliroside, an acyl-glycosilated flavonoid ubiquitous in all tested extracts, seems to play an important role in the observed moderate activity of most extracts against the leukemia K562 cell lineage.

  15. Anti-leukemic activity of Wattakaka volubilis leaf extract against human myeloid leukemia cell lines.

    Science.gov (United States)

    Nandi, Debkumar; Besra, Shila Elizabeth; Vedasiromoni, Joseph Rajan; Giri, Venkatachalam Sesha; Rana, Prince; Jaisankar, Parasuraman

    2012-12-18

    Wattakaka volubilis has been traditionally used in Ayurvedic medicine in India for treatment of several ailments such as bronchial asthma, inflammations, tumors, piles, leucoderma, application to boils, rat bite etc. The present study was designed to investigate anti-leukemic activity of the crude aqueous methanolic extract and to identify active compounds from the leaves of Wattakaka volubilis. The leaves of Wattakaka volubilis were extracted with aqueous methanol. Liquid-liquid fractionation of the crude methanolic extract with different organic solvents was done and the fractions were screened for in vitro anti-leukemic activity using different leukemic cell lines. The active fractions were then subjected to chromatographic separation for isolation of bioactive compounds. Structure of isolated compound was elucidated by spectroscopic methods. The in vitro anti-leukemic activities of different extracts of the leaves and isolated compound WVP were studied in U-937, HL-60 and K-562 cell-lines by using cell count, MTT [(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide] and DNA laddering assays, flow-cytometric and confocal microscopic techniques. Kaempferol-3-O-[α-l-rhamnopyranosyl-(1→4)-O-α-l-rhamnopyranosyl-(1→6)-O]-β-d-glucopyranoside (WVP) was isolated from crude leaves extract of Wattakaka volubilis. Both the n-butanolic extract (WVB) of Wattakaka volubilis and its isolate WVP were found to be responsible for in vitro anti-leukemic activity. The IC(50) values of WVB were found be 120, 100 and 50(μg/ml) in U937, K562, and HL-60 cell lines, respectively. Whereas, the pure isolate WVP exhibited anti-leukemic activity with IC(50) values of 13.5, 10.8, and 13.2(μg/ml) in U937, K562, and HL-60 cell lines, respectively. The flow-cytometric analysis confirms that the cell cycle arrest occurs at G1 phase in case of U937 and K562 cell lines and G2/M phase in case of HL60 cell lines. Similarly both confocal microsocopic analysis and DNA laddering assay

  16. Discrimination of charged particles in a neutral beam line by using a solid scintillation detector

    Science.gov (United States)

    Woo, Jong-Kwan; Ko, Jewou; Liu, Dong

    2017-01-01

    In the past several decades, many studies have been conducted to search for non-baryonic dark matter, such as weakly interactive massive particles (WIMPs). In the search for WIMPs, charged particles incident on the detector are background particles because WIMPs are neutral. Charged particles originate from various sources, such as cosmic rays and laboratory materials surrounding the main detector. Therefore, a veto that discriminates charged particles can improve the particle-detection efficiency of the entire experiment for detecting WIMPs. Here, we investigate in the thickness range of 1 mm to 5 mm, the optimal thickness of a polystyrene scintillator as a chargedparticle veto detector. We found that 3-mm-thick polystyrene provides the best performance to veto charged particles and the charged-particle background in the search for the WIMP signal. Furthermore, we fabricated 3-mm-thick and 5-mm-thick polystyrene charged particle veto detectors that will be used in an underground laboratory in the search for WIMP dark matter. After exposing those detectors are the actual beam line, we compared the rate of charged particles measured using those detectors and the rate simulated through a Monte Carlo simulation.

  17. Simulation of H{sup -} ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T.; Tarvainen, O. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae (Finland); Welton, R. F.; Han, B. X.; Stockli, M. P. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2012-02-15

    A three-dimensional ion optical code IBSimu, which is being developed at University of Jyvaeskylae, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H{sup -} ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H{sup -} currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  18. Optics Measurements and Matching of TT2-TT10 Line for Injection of the LHC Beam in the SPS

    CERN Document Server

    Benedetto, E; Guerrero, A; Jacquet, D

    2008-01-01

    A well matched injection in the SPS is very important for preserving the emittance of the LHC beam. The paper presents the algorithms used for the analysis and the results of the optics measurements done in the transfer line TT2-TT10 and in the SPS. The dispersion is computed by varying the beam momentum and recording the offsets at the BPMs, while the Twiss parameters and emittance measurements in TT2-TT10 are performed with beam profile monitors equipped with OTR screens. These results are completed by those obtained with a matching monitor installed in the SPS as a prototype for the LHC. This device makes use of an OTR screen and a fast acquisition system, to get the turn by turn beam profiles right at injection in the ring, from which the beam mismatch is computed and compared with the results obtained in the line. Finally, on the basis of such measurements, a betatron and dispersion matching of TT2-TT10 for injection in the SPS has been performed and successfully put in operation.

  19. A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Bing, E-mail: tangb364@126.com; Ma, Ruigang; Huang, Qinghua; Chen, Lihua; Ma, Yingjun; Cui, Baoqun; Jiang, Weisheng

    2013-12-15

    Highlights: • The modular design makes the maintenance of target station easily. • The diagnosis for low intensity beam is solved. • A positive surface ion source has been developed. -- Abstract: A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility (BRISOL) has been built in China Institute of Atomic Energy (CIAE). The test-bench consists of target station, charge exchange cell, mass separator, quadrupole, hexapole, multipole and beam diagnostic system. It is nearly the same configuration as the first stage of BRISOL and all these components will be used on the BRISOL. A series of experiments have been carried out on this test-bench, and the primary results showed that all the components worked well. A Li{sup +} beam has been generated from the positive surface-ionization source and its emittance and the transmission of the beam line have been measured. The design, construction and experimental results of this test-bench have been presented.

  20. Development of a system for monitoring the shape, position, and intensity of the extracted relativistic ion beam at the Nuclotron-M accelerator complex at JINR

    Science.gov (United States)

    Vasilev, S. E.; Vishnevskiy, A. V.; Kadykov, M. G.; Makankin, A. M.; Tyutyunnikov, S. I.; Shurygin, A. A.

    2014-11-01

    Test samples of detectors and electronics for them constructed for the purpose of monitoring the "intense" relativistic ion beams extracted from the accelerator of the Nuclotron-M accelerator complex in real time are described. The system was tested in a series of acceleration runs with deuteron beams with an intensity of up to 1010 1/s and beams of carbon nuclei. The system allows one to perform multiple measurements of the two-dimensional distribution of the beam intensity in the plane perpendicular to it and the beam position in this plane during the beam dump and measure the two-dimensional distribution of the target irradiation dose after each beam dump.

  1. Design of Main Control Console Software in EAST Neutral Beam Injector's Control System for the First Beam Line

    Science.gov (United States)

    Wu, De-Yun; Hu, Chun-Dong; Sheng, Peng; Zhao, Yuan-Zhe; Zhang, Xiao-Dan; Cui, Qing-Long

    2013-10-01

    Neutral beam injector is one of the main plasma heating and plasma current driving methods for experimental advanced superconducting tokomaks (EAST). In order to realize visual operation of EAST neutral beam injector's control system (NBICS), main control console (MCC) is developed to work as the human-machine interface between the NBICS and physical operator. It can meet the requirements of visual control of NBICS by providing a user graphic interface. With the specific algorithms, the setup of power supply sequence is relatively independent and simple. Displaying the real-time feedback of the subsystems provides a reference for operators to monitor the status of the system. The MCC software runs on a Windows system and uses C++ language code while using client/server (C/S) mode, multithreading and cyclic redundancy check technology. The experimental results have proved that MCC provides a stability and reliability operation of NBICS and works as an effective man-machine interface at the same time.

  2. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Valerio-Lizarraga, Cristhian A., E-mail: cristhian.alfonso.valerio.lizarraga@cern.ch [CERN, Geneva (Switzerland); Departamento de Investigación en Física, Universidad de Sonora, Hermosillo (Mexico); Lallement, Jean-Baptiste; Lettry, Jacques; Scrivens, Richard [CERN, Geneva (Switzerland); Leon-Monzon, Ildefonso [Facultad de Ciencias Fisico-Matematicas, Universidad Autónoma de Sinaloa, Culiacan (Mexico); Midttun, Øystein [CERN, Geneva (Switzerland); University of Oslo, Oslo (Norway)

    2014-02-15

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H{sup −} beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  3. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions.

    Science.gov (United States)

    Valerio-Lizarraga, Cristhian A; Lallement, Jean-Baptiste; Leon-Monzon, Ildefonso; Lettry, Jacques; Midttun, Øystein; Scrivens, Richard

    2014-02-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H(-) beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  4. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Science.gov (United States)

    Valerio-Lizarraga, Cristhian A.; Lallement, Jean-Baptiste; Leon-Monzon, Ildefonso; Lettry, Jacques; Midttun, Øystein; Scrivens, Richard

    2014-02-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H- beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  5. Automatic Building Extraction and Roof Reconstruction in 3k Imagery Based on Line Segments

    Science.gov (United States)

    Köhn, A.; Tian, J.; Kurz, F.

    2016-06-01

    We propose an image processing workflow to extract rectangular building footprints using georeferenced stereo-imagery and a derivative digital surface model (DSM) product. The approach applies a line segment detection procedure to the imagery and subsequently verifies identified line segments individually to create a footprint on the basis of the DSM. The footprint is further optimized by morphological filtering. Towards the realization of 3D models, we decompose the produced footprint and generate a 3D point cloud from DSM height information. By utilizing the robust RANSAC plane fitting algorithm, the roof structure can be correctly reconstructed. In an experimental part, the proposed approach has been performed on 3K aerial imagery.

  6. Production of chemically reactive radioactive ion beams through on-line separation; Production de faisceaux d'ions radioactifs chimiquement reactifs par separation en ligne

    Energy Technology Data Exchange (ETDEWEB)

    Joinet, A

    2003-10-01

    The ISOL (isotope separation on line) allows the production of secondary radioactive ion beams through spallation or fragmentation or fission reactions that take place in a thick target bombarded by a high intensity primary beam. The challenge is to increase the intensity and purity of the radioactive beam. The optimization of the system target/source requires the right choice of material for the target by taking into account the stability of the material, its reactivity and the ionization method used. The target is an essential part of the system because radioactive elements are generated in it and are released more or less quickly. Tests have been made in order to select the best fitted material for the release of S, Se, Te, Ge and Sn. Materials tested as target filling are: ZrO{sub 2}, Nb, Ti, V,TiO{sub 2}, CeO{sub x}, ThO{sub 2}, C, ZrC{sub 4} and VC). Other molecules such as: COSe, COS, SeS, COTe, GeS, SiS, SnS have been studied to ease the extraction of recoil nuclei (Se, S, Te, Ge and Sn) produced inside the target.

  7. Basic test framework for the evaluation of text line segmentation and text parameter extraction.

    Science.gov (United States)

    Brodić, Darko; Milivojević, Dragan R; Milivojević, Zoran

    2010-01-01

    Text line segmentation is an essential stage in off-line optical character recognition (OCR) systems. It is a key because inaccurately segmented text lines will lead to OCR failure. Text line segmentation of handwritten documents is a complex and diverse problem, complicated by the nature of handwriting. Hence, text line segmentation is a leading challenge in handwritten document image processing. Due to inconsistencies in measurement and evaluation of text segmentation algorithm quality, some basic set of measurement methods is required. Currently, there is no commonly accepted one and all algorithm evaluation is custom oriented. In this paper, a basic test framework for the evaluation of text feature extraction algorithms is proposed. This test framework consists of a few experiments primarily linked to text line segmentation, skew rate and reference text line evaluation. Although they are mutually independent, the results obtained are strongly cross linked. In the end, its suitability for different types of letters and languages as well as its adaptability are its main advantages. Thus, the paper presents an efficient evaluation method for text analysis algorithms.

  8. Comparison of the cytotoxic effects of Juniperus sabina and Zataria multiflora extracts with Taxus baccata extract and Cisplatin on normal and cancer cell lines

    Science.gov (United States)

    Shokrzadeh, M.; Azadbakht, M.; Ahangar, N.; Naderi, H.; Saeedi Saravi, S. S.

    2010-01-01

    Isolation and identification of some potent anti-tumor compounds from medicinal plants has motivated researchers to screen different parts of plant species for the determination of anti-tumor effects. In this study, cytotoxic effects and IC50 of specific concentrations of hydro-alcoholic extracts of fruits of Juniperus sabina and leaves of Zataria multiflora were compared with hydro-alcoholic extract of bark of Taxus baccata and Cisplatin, well-known anticancer compounds, on normal (CHO and rat fibroblast) and cancer (HepG2 and SKOV3) cell lines. The hydro-alcoholic extracts of the plants were prepared by percolation. The cytotoxic effects and IC50 of the extracts on the cell lines were studied followed by colonogenic assay after 72 h incubation. The results showed that the extract of Juniperus sabina possesses lower IC50 in comparison with Zataria multiflora extract on all 4 normal and cancer cell lines (PJuniperus sabina extract was significantly higher than the Taxus baccata extract and Cisplatin on all 4 normal and cancer cell lines (P<0.05). As a result, it is concluded that the extract of J. sabina has almost similar cytotoxicity with the extract of Taxus baccata on cancer cells. PMID:20668574

  9. Bevalac extraction

    Energy Technology Data Exchange (ETDEWEB)

    Kalnins, J.G.; Krebs, G.; Tekawa, M.; Cowles, D.; Byrne, T.

    1992-02-01

    This report will describe some of the general features of the Bevatron extraction system, primarily the dependence of the beam parameters and extraction magnet currents on the Bevalac field. The extraction magnets considered are: PFW, XPl, XP2, XS1, XS2, XM1, XM2, XM3, XQ3A and X03B. This study is based on 84 past tunes (from 1987 to the present) of various ions (p,He,O,Ne,Si,S,Ar,Ca,Ti,Fe,Nb,La,Au and U), for Bevalac fields from 1.749 to 12.575 kG, where all tunes included a complete set of beam line wire chamber pictures. The circulating beam intensity inside the Bevalac is measured with Beam Induction Electrodes (BIE) in the South Tangent Tank. The extracted beam intensity is usually measured with the Secondary Emission Monitor (SEM) in the F1-Box. For most of the tunes the extraction efficiency, as given by the SEM/BIE ratio, was not recorded in the MCR Log Book, but plotting the available Log Book data as a function of the Bevalac field, see Fig.9, we find that the extraction efficiency is typically between 30->60% with feedback spill.

  10. Protocol of image guided off-line using cone beam CT megavoltage; Protocolo de imagen guiada off-line mediante Cone Beam CT de megavoltaje

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Ruiz-Zorrilla, J.; Fernandez Leton, J. P.; Perez Moreno, J. M.; Zucca Aparicio, D.; Minambres Moro, A.

    2013-07-01

    The goal of image guided protocols offline is to reduce systematic errors in positioning of the patient in the treatment unit, being more important than the random errors, since the systematic have one contribution in the margin of the CTV to the PTV. This paper proposes a protocol for image guided offline with the different actions to take with their threshold values evaluated previously by anatomic location in a sample of 474 patients and 4821Cone beam Megavoltaje CT (CBCT). (Author)

  11. Adaptive Pulsed Laser Line Extraction for Terrain Reconstruction using a Dynamic Vision Sensor

    Directory of Open Access Journals (Sweden)

    Christian eBrandli

    2014-01-01

    Full Text Available Mobile robots need to know the terrain in which they are moving for path planning and obstacle avoidance. This paper proposes the combination of a bio-inspired, redundancy-suppressing dynamic vision sensor with a pulsed line laser to allow fast terrain reconstruction. A stable laser stripe extraction is achieved by exploiting the sensor’s ability to capture the temporal dynamics in a scene. An adaptive temporal filter for the sensor output allows a reliable reconstruction of 3D terrain surfaces. Laser stripe extractions up to pulsing frequencies of 500Hz were achieved using a line laser of 3mW at a distance of 45cm using an event-based algorithm that exploits the sparseness of the sensor output. As a proof of concept, unstructured rapid prototype terrain samples have been successfully reconstructed with an accuracy of 2mm.

  12. Cytotoxic effect of Spirulina platensis extracts on human acute leukemia Kasumi-1 and chronic myelogenous leukemia K-562 cell lines

    Directory of Open Access Journals (Sweden)

    Flor Yohana Flores Hernandez

    2017-01-01

    Conclusions: The cytotoxicity exhibited by Spirulina extract to cancer cell lines might be due to the presence of phytopigments (carotenoids, chlorophyll, phycocyanin as well as polysaccharides that were reported previously as constituents of the extract. So crude extracts of Spirulina can be used as a source to develop anticancer drugs.

  13. Clinacanthus nutans Extracts Are Antioxidant with Antiproliferative Effect on Cultured Human Cancer Cell Lines

    OpenAIRE

    Yoke Keong Yong; Jun Jie Tan; Soek Sin Teh; Siau Hui Mah; Gwendoline Cheng Lian Ee; Hoe Siong Chiong; Zuraini Ahmad

    2013-01-01

    Clinacanthus nutans Lindau leaves (CN) have been used in traditional medicine but the therapeutic potential has not been explored for cancer prevention and treatment. Current study aimed to evaluate the antioxidant and antiproliferative effects of CN, extracted in chloroform, methanol, and water, on cancer cell lines. Antioxidant properties of CN were evaluated using DPPH, galvinoxyl, nitric oxide, and hydrogen peroxide based radical scavenging assays, whereas the tumoricidal effect was teste...

  14. X-ray diffraction using synchrotron radiation on the G.I.L.D.A. beam line at the E.S.R.F

    Energy Technology Data Exchange (ETDEWEB)

    Balerna, A. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Meneghini, C. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)]|[INFM, Genoa (Italy); Bordoni, S. [Rome Univ. `Tor Vergata` (Italy). Dip. di Fisica; Mobilio, S. [Rome Univ. III (Italy). Dip. di Fisica `E. Amaldi`

    1996-09-01

    The aim of this lecture is to make a short introduction on Synchrotron radiation, its history and main properties. The main components of a synchrotron radiation beam line will be described. The Italian beam line, General purpose Italian beam line Line for Diffraction and Absorption (G.I.L.D.A.) at the European Synchrotron Radiation Facility (E.S.R.F.) in Grenoble will be used as an example. The G.I.L.D.A. diffractometer will be described in detail reporting also some experimental results.

  15. Cytotoxic activity of Piper cubeba extract in breast cancer cell lines.

    Science.gov (United States)

    Graidist, Potchanapond; Martla, Mananya; Sukpondma, Yaowapa

    2015-04-10

    This study aimed to evaluate the cytotoxicity of a crude extract of Piper cubeba against normal and breast cancer cell lines. To prepare the extract, P. cubeba seeds were ground, soaked in methanol and dichloromethane and isolated by column chromatography. Fractions were tested for cytotoxicity effects on normal fibroblast (L929), normal breast (MCF-12A) and breast cancer cell lines (MCF-7, MDA-MB-468 and MDA-MB-231). The most effective fraction was selected for DNA fragmentation assay to detect apoptotic activity. The results showed that the methanolic crude extract had a higher cytotoxic activity against MDA-MB-468 and MCF-7 than a dichloromethane crude extract. Then, the methanolic crude extract was separated into six fractions, designated A to F. Fraction C was highly active against breast cancer cell lines with an IC50 value less than 4 μg/mL. Therefore, Fraction C was further separated into seven fractions, CA to CG. The 1H-NMR profile showed that Fraction CE was long chain hydrocarbons. Moreover, Fraction CE demonstrated the highest activity against MCF-7 cells with an IC50 value of 2.69 ± 0.09 μg/mL and lower cytotoxicity against normal fibroblast L929 cells with an IC50 value of 4.17 ± 0.77 μg/mL. Finally, DNA fragmentation with a ladder pattern characteristic of apoptosis was observed in MCF-7, MDA-MB-468, MDA-MB-231 and L929 cells, but not in MCF-12A cells.

  16. Robust breathing signal extraction from cone beam CT projections based on adaptive and global optimization techniques

    Science.gov (United States)

    Chao, Ming; Wei, Jie; Li, Tianfang; Yuan, Yading; Rosenzweig, Kenneth E.; Lo, Yeh-Chi

    2016-04-01

    We present a study of extracting respiratory signals from cone beam computed tomography (CBCT) projections within the framework of the Amsterdam Shroud (AS) technique. Acquired prior to the radiotherapy treatment, CBCT projections were preprocessed for contrast enhancement by converting the original intensity images to attenuation images with which the AS image was created. An adaptive robust z-normalization filtering was applied to further augment the weak oscillating structures locally. From the enhanced AS image, the respiratory signal was extracted using a two-step optimization approach to effectively reveal the large-scale regularity of the breathing signals. CBCT projection images from five patients acquired with the Varian Onboard Imager on the Clinac iX System Linear Accelerator (Varian Medical Systems, Palo Alto, CA) were employed to assess the proposed technique. Stable breathing signals can be reliably extracted using the proposed algorithm. Reference waveforms obtained using an air bellows belt (Philips Medical Systems, Cleveland, OH) were exported and compared to those with the AS based signals. The average errors for the enrolled patients between the estimated breath per minute (bpm) and the reference waveform bpm can be as low as  -0.07 with the standard deviation 1.58. The new algorithm outperformed the original AS technique for all patients by 8.5% to 30%. The impact of gantry rotation on the breathing signal was assessed with data acquired with a Quasar phantom (Modus Medical Devices Inc., London, Canada) and found to be minimal on the signal frequency. The new technique developed in this work will provide a practical solution to rendering markerless breathing signal using the CBCT projections for thoracic and abdominal patients.

  17. Induction of apoptosis in cancer cell lines by the Red Sea brine pool bacterial extracts.

    Science.gov (United States)

    Sagar, Sunil; Esau, Luke; Holtermann, Karie; Hikmawan, Tyas; Zhang, Guishan; Stingl, Ulrich; Bajic, Vladimir B; Kaur, Mandeep

    2013-12-05

    Marine microorganisms are considered to be an important source of bioactive molecules against various diseases and have great potential to increase the number of lead molecules in clinical trials. Progress in novel microbial culturing techniques as well as greater accessibility to unique oceanic habitats has placed the marine environment as a new frontier in the field of natural product drug discovery. A total of 24 microbial extracts from deep-sea brine pools in the Red Sea have been evaluated for their anticancer potential against three human cancer cell lines. Downstream analysis of these six most potent extracts was done using various biological assays, such as Caspase-3/7 activity, mitochondrial membrane potential (MMP), PARP-1 cleavage and expression of γH2Ax, Caspase-8 and -9 using western blotting. In general, most of the microbial extracts were found to be cytotoxic against one or more cancer cell lines with cell line specific activities. Out of the 13 most active microbial extracts, six extracts were able to induce significantly higher apoptosis (>70%) in cancer cells. Mechanism level studies revealed that extracts from Chromohalobacter salexigens (P3-86A and P3-86B(2)) followed the sequence of events of apoptotic pathway involving MMP disruption, caspase-3/7 activity, caspase-8 cleavage, PARP-1 cleavage and Phosphatidylserine (PS) exposure, whereas another Chromohalobacter salexigens extract (K30) induced caspase-9 mediated apoptosis. The extracts from Halomonas meridiana (P3-37B), Chromohalobacter israelensis (K18) and Idiomarina loihiensis (P3-37C) were unable to induce any change in MMP in HeLa cancer cells, and thus suggested mitochondria-independent apoptosis induction. However, further detection of a PARP-1 cleavage product, and the observed changes in caspase-8 and -9 suggested the involvement of caspase-mediated apoptotic pathways. Altogether, the study offers novel findings regarding the anticancer potential of several halophilic bacterial

  18. The Circulation Distribution on the Lifting Line for a Given Extracted Power

    Directory of Open Access Journals (Sweden)

    Ali Helali

    2012-01-01

    Full Text Available Presently, there exist few numerical methods which treat the inverse problem for the determination of the geometry of wind turbine blades. In this work, authors intend to solve the inverse optimum project for horizontal axis wind turbine in which the selection of the circulation distribution is obtained by resolving two variational problems: the first consists in sorting the circulation distribution on the lifting line, which, for a given power extracted by the wind turbine, minimizes the loses due to the induced velocity. In the second, the optimal circulation distribution is selected such that the kinetic energy of the wind downstream of the rotor disc is minimum, when the energy extracted by the wind turbine for one rotating period is imposed. A code has been developed which incorporates the real pitch of the helicoidal vortex wake. Very promising results have been obtained: the circulation distribution for a given extracted power and the chord lengths distribution law along the blade span.

  19. First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)

    Energy Technology Data Exchange (ETDEWEB)

    Lawrie, Scott R., E-mail: scott.lawrie@stfc.ac.uk [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom); John Adams Institute for Accelerator Science, Department of Physics, University of Oxford (United Kingdom); Faircloth, Daniel C.; Letchford, Alan P.; Perkins, Mike; Whitehead, Mark O.; Wood, Trevor [ISIS Neutron and Muon Facility, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX (United Kingdom)

    2015-04-08

    In order to facilitate the testing of advanced H{sup −} ion sources for the ISIS and Front End Test Stand (FETS) facilities at the Rutherford Appleton Laboratory (RAL), a Vessel for Extraction and Source Plasma Analyses (VESPA) has been constructed. This will perform the first detailed plasma measurements on the ISIS Penning-type H{sup −} ion source using emission spectroscopic techniques. In addition, the 30-year-old extraction optics are re-designed from the ground up in order to fully transport the beam. Using multiple beam and plasma diagnostics devices, the ultimate aim is improve H{sup −} production efficiency and subsequent transport for either long-term ISIS user operations or high power FETS requirements. The VESPA will also accommodate and test a new scaled-up Penning H{sup −} source design. This paper details the VESPA design, construction and commissioning, as well as initial beam and spectroscopy results.

  20. Characteristics of extracted beam from a synchrotron using a fast Q-magnet assisted by RF-knockout

    Science.gov (United States)

    Nakanishi, Tetsuya; Furukawa, Takuji; Noda, Koji

    2008-05-01

    Beam experiment has been carried out at the HIMAC synchrotron to study characteristics of a beam extracted with alternate operation of a fast Q-magnet (FQ) to extract and RF-knockout to diffuse a circulating beam. The FQ coil current of a chopping wave was used to find a particle density distribution after the diffusion. Two kinds of RF-knockout signal were used: a colored noise and a frequency modulation signal. The results showed that the spill structure was like an exponential wave pattern roughly and nearly constant by use of the colored noise and was varied with the frequency modulation signal. The colored noise also gave a nearly constant diffusion rate.

  1. SEMIAUTOMATIC BUILDING EXTRACTION FROM STEREOIMAGE PAIR BASED ON LINES GROUPING AND LEAST SQUARES MATCHING

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The paper presents a general paradigm of semiautomatic building extrac tion from aerial stereo image pair.In the semiautomatic extraction system,the building model is defined by selected roof type through human-machine interface and input the approximation of area where the extracted building exists.Then un der the knowledge of the roof type,low-level and mid-level processing including edge detection,straight line segments extraction and line segments grouping ar e used to establish the initial geometrical model of the roof-top.However,the initial geometrical model is not so accurate in geometry.To attain accurate res ults,a general least squares adjustment integrating the linear templates matchin g model with geometrical constraints in object-space is applied to refine the ini tial geometrical model.The adjustment model integrating the straight edge pat tern and 3D constraints together is a well-studied optimal and ant i-noise method.After gaining proper initial values,this adjustment model can f lexibly process extraction of kinds of roof types by changing or assembling the geometrical constraints in object-space.

  2. Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Won; Lee, Won; Lee, Byung Do [Department of Oral and Maxillofacial Radiology, School of Dentistry, Wonkwang University, Iksan (Korea, Republic of); Kim, De Sok [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2009-03-15

    To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  3. Investigation of regime of intensive extraction of proton beam by curved crystal during simultaneous operation with internal targets on IHEP-U-70 accelerator

    CERN Document Server

    Afonin, A G; Galjaev, A N; Gres, V N; Grishina, S Y; Zapolskii, V N; Zelenov, B A; Kotov, V I; Maisheev, V A; Medvedev, V A; Minchenko, A V; Terekhov, V I; Troyanov, E F; Fedotov, Y S; Chesnokov, Yu A

    2002-01-01

    On describes a technique to extract proton beam from the IHEP U-70 synchrotron using a silicon curved crystal at simultaneous operation of several internal targets. The optimal range of crystal angles of curvature constitutes 0.5-2.5 mrad, beam length - 2-5 mm. The intensity range of the extracted beam may vary depending on the requirements imposed by physical experimental facilities ranging from 10 sup 7 up to 6.0 x 10 sup 1 sup 1 protons per U-70 operation cycle. The elaborated technique to extract accelerated beam by short crystals extends essentially possibilities to conduct physical researches using an accelerator

  4. Optics Measurements and Matching of TT2-TT10 Line for Injection of the LHC Beam in the SPS

    CERN Document Server

    Benedetto, E

    2008-01-01

    A well matched injection in the SPS is very important for preserving the emittance of the LHC beam. The paper presents the algorithms used for the analysis and the results of the 2007 optics measurements campaign done in the transfer line TT2-TT10 and in the SPS. The dispersion is computed by varying the beam momentum and recording the offsets at the BPMs, while the Twiss parameters and emittance measurements in TT2-TT10 are performed with beam profile monitors equipped with OTR screens. Finally, on the basis of such measurements, a betatron and dispersion matching of TT2-TT10 for injection in the SPS has been performed and successfully put in operation since October 2007.

  5. Automatic extraction of sulcal lines on cortical surfaces based on anisotropic geodesic distance.

    Science.gov (United States)

    Seong, Joon-Kyung; Im, Kiho; Yoo, Sang Wook; Seo, Sang Won; Na, Duk L; Lee, Jong-Min

    2010-01-01

    Analyzing cortical sulci is important for studying cortical morphology and brain functions. Although sulcal lines on cortical surfaces can be defined in various ways, it is critical in a neuroimaging study to define a sulcal line along the valley of a cortical surface with a high curvature within a sulcus. To extract the sulcal lines automatically, we present a new geometric algorithm based on the computation of anisotropic skeletons of sulcal regions. Because anisotropic skeletons are highly adaptive to the anisotropic nature of the surface shape, the resulting sulcal lines lie accurately on the valleys of the sulcal areas. Our sulcal lines remain unchanged under local shape variabilities in different human brains. Through experiments, we show that the errors of the sulcal lines for both synthetic data and real cortical surfaces were nearly as constant as the function of random noise. By measuring the changes in sulcal shape in Alzheimer's disease (AD) patients, we further investigated the effectiveness of the accuracy of our sulcal lines using a large sample of MRI data. This study involved 70 normal controls (n [men/women]: 29/41, age [mean+/-SD]: 71.7+/-4.9 years), and 100 AD subjects (37/63, 72.3+/-5.5). We observe significantly lower absolute average mean curvature and shallower sulcal depth in AD subjects, where the group difference becomes more significant if we measure the quantities along the sulcal lines rather than over the entire sulcal area. The most remarkable difference in the AD patients was the average sulcal depth (control: 11.70 and AD: 11.34).

  6. GEANT4 simulation of the ACE beam line : Measurement of the energy distribution of degraded Antiproton beam and the ToF signal of generated pions.

    CERN Document Server

    BRAHIMI, Nihel

    2014-01-01

    The present document describes my 8 weeks work project as a summer student at the AEgIS experiment under the supervision of Michael Doser and what i have learned during this period . It can be devided into three main tasks which are: Theoretical preparations concerning low energy antiproton physics. Learning the basic principles of GEANT4 simu- lation toolkit. Using GEANT4 platform to follow up the work of two technical students (Logan and Conrad) in designing an experiment (ACE beam line ) which aims at improving the methods of detect- ing matter-antimatter annihilations vertices at low energies in terms of resolution and accuracy using hybrid detectors .

  7. Performance of a superconducting magnet system operated in the Super Omega Muon beam line at J-PARC

    Energy Technology Data Exchange (ETDEWEB)

    Makida, Yasuhiro; Ikedo, Yutaka; Ogitsu, Toru; Shimomura, Koichiro; Miyake, Yasuhiro; Yoshida, Makoto; Adachi, Taihei; Kadono, Ryosuke; Kawamura, Naritoshi; Strasser, Patric; Koda, Akihiro; Fujimori, Hiroshi; Nishiyama, Kusuo; Ohhata, Hirokatsu; Okamura, Takahiro; Okada, Ryutaro [J-PARC, KEK, Shirakata 203-1, Tokai, Naka, Ibaraki (Japan); Orikasa, Tomofumi [Keihin Product Operations, Toshiba, Suehiro 2-4, Tsurumi, Yokohama (Japan)

    2014-01-29

    A superconducting magnet system, which is composed of an 8 m long solenoid for transportation and 12 short solenoids for focusing, has been developed for Muon Science Establishment facility of J-PARC. The transport solenoid is composed of a 6 m straight section connected to a 45 degree curved section at each end. Muons of various momenta and of both electric charges are transported through the solenoid inner bore with an effective diameter of 0.3 m, where 2 T magnetic field is induced. There are 12 focusing solenoids with an effective bore diameter of 0.6 m and a length of 0.35 m arranged on a straight line at suitable intervals. The maximum central field of each focusing solenoid is 0.66 T. All solenoid coils are cooled by GM cryocoolers through their own conductions. The magnet system has been installed into the beam line in the summer of 2012, and its performance has been checked. Beam commissioning has been carried out since October 2012. During beam operation, temperature rise over 6 K in the transport solenoid due to a nuclear heating from the muon production target is observed at beam intensity of about 300 kW.

  8. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Science.gov (United States)

    Huerta-Parajon, M.; Martinez-Ballarin, R.; Abad, E.

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 106 protons/cm2 s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  9. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Huerta-Parajon, M., E-mail: mhuerta@essbilbao.org; Martinez-Ballarin, R., E-mail: rmartinez@essbilbao.org; Abad, E., E-mail: eabad@essbilbao.org

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 10{sup 6} protons/cm{sup 2} s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  10. Transcriptional network in ovarian cancer cell line SKOV3 treated with Pinellia pedatisecta Schott extract.

    Science.gov (United States)

    Zhou, Li; Xu, Teng; Zhang, Ying; Zhu, Mei; Zhu, Wen; Wang, Ziqiang; Gu, Hangzhi; Wang, Hanchu; Li, Peizhen; Ying, Jun; Yang, Lei; Ren, Ping; Li, Jinsong; Xu, Zuyuan; Ni, Liyan; Bao, Qiyu; Chen, Jindong

    2016-07-01

    Ovarian cancer is the most lethal disease among the malignant tumors of female reproductive organs. Few successful therapeutic options exist for patients with ovarian cancer. The common therapeutic methods are surgical operation, chemotherapy, radiotherapy, and combination of these treatments. In recent years, studies have indicated that Pinellia pedatisecta Schott (PPS), a traditional Chinese medicine, could inhibit tumor growth. In this study, we demonstrated that PPS extract could induce apoptosis in SKOV3 cells in a dose- and time-dependent manner. We further conducted transcriptome sequencing on PPS extract-treated SKOV3 cells along with controls, and identified 1,754 transcripts whose expression differs at least 3-fold over the controls. These differentially expressed transcripts include the apoptosis-related genes such as the caspase family members, and were significantly enriched in steroid biosynthesis in the KEGG pathway database compared with the transcriptome background. Most of the differentially expressed transcripts from this pathway were upregulated in PPS extract-treated cell line, indicating that PPS extract-induced apoptosis was accompanied by increased steroid biosynthesis (e.g. zymosterol). These results suggest that PPS extract could be a new cytostatic therapeutic agent for ovarian cancer.

  11. Simulation on the Pulsed Beam Transport for Injection Line of CYCIAE-10

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    1 Introduction The development of a 40 keV, 18 mA multi-cusp H- ion source and beam pulsing system have been completed successfully at CIAE. The pulsed H- beam with a repetition rate of 4.4 MHz and a pulse length of 9.6 ns has been obtained. In order to

  12. Pharmacological activity of Kaempferia parviflora extract against human bile duct cancer cell lines.

    Science.gov (United States)

    Leardkamolkarn, Vijittra; Tiamyuyen, Sunida; Sripanidkulchai, Bung-orn

    2009-01-01

    A crude ethanol extract of Kaemperia parviflora Wall. Ex Baker and a purified compound, 5,7,4-trimethoxyflavone (KP.8.10), were evaluated for pharmacological effects on human cholangiocarcinoma cell lines (HuCCA-1 and RMCCA-1). The cells were incubated with various concentrations of extract for various time periods and metabolic activity (MTT assay) was assessed for cell viability. The results showed a dose-dependent effect of both crude ethanol extract and the pure compound. CC50s for the crude extract on HuCCA-1 and RMCCA-1 cells were 46.1 microg/ml and 62.0 microg/ml, respectively. Values for the pure compound could not be determined because of solubility problems. Interestingly, K. parviflora ethanol extract and KP.8.10 at low concentrations (10-20 microg/ml and 2.5-5 microg/ml, respectively) markedly reduced rhHGF-induced invasion by HuCCA-1 and RMCCA-1 cells across matrix-coated transwell plates. Higher concentrations of K. parviflora ethanol extract (60 and 80 microg/ml) and KP.8.10 (20 microg /ml) dramatically changed the cellular morphology and caused death in both cell types. KP.8.10 further exhibited progressive action via caspase-3 mitochondrial enzyme activation, enhancing cellular toxicity in a time-dose dependent fashion. Therefore, 5,7,4-trimethoxyflavone appeared to be a bioactive component of K. parviflora extract capable of exerting anti-cancer action. The results suggested a benefit of this edible plant in prevention and treatment of cholangiocarcinoma.

  13. Design, fabrication and testing of elliptical crystal bender for the EXAFS beam-line at INDUS-II synchrotron source

    Indian Academy of Sciences (India)

    N C Das; S N Jha; D Bhattacharyya; A K Poswal; A K Sinha; V K Mishra

    2004-10-01

    An extended X-ray absorption fine structure (EXAFS) beam-line for X-ray absorption studies using energy dispersive geometry and position sensitive detector is being developed for the INDUS-II synchrotron source. The optical design of the beam-line has been completed based on the working principle that a single crystal bent in the shape of an ellipse by a crystal bender would act as a dispersing as well as focusing element. The heart of the beam-line is the crystal bender which has been designed on the basis of the principle of four-point bending and has been fabricated indigenously. The crystal bender is capable of producing pre-defined elliptical curvature on a crystal surface by applying different couples at the two-ends of the crystal which has variable width along its length. The focusing property of the crystal bender has been tested using a laser source and has been compared with the theoretically simulated results.

  14. Beam size reduction of a several hundred-keV compact ion microbeam system by improving the extraction condition in an ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Yasuyuki; Ohkubo, Takeru; Kamiya, Tomihiro; Saitoh, Yuichi

    2015-04-01

    A several hundred-keV compact ion microbeam system with a three-stage acceleration lens has been developed to form an ion beam of several micrometers in diameter. In a previous study of the Ohkubo et al. (2013) and Ishii et al. (2014), a hydrogen beam of 143 keV having 17 μm diameter was experimentally formed using such a microbeam system. It was demonstrated that a three-stage acceleration lens functioned as a focusing lens and indicated that the beam diameter (hereinafter referred to as the “beam size”) depended on the extraction voltage to generate the ion beam and the vacuum pressure in the extraction space in a plasma-type ion source. In this study, the hydrogen beam sizes were experimentally measured at 130 keV as functions of the extraction voltage and vacuum pressure to form the beam size with several micrometers in diameter. These two relationships showed that beam sizes were reduced in the extraction voltage range of 400–500 V and when the vacuum pressure was lowered to a minimum value of 5.33 × 10{sup −5} Pa. In addition, the result showed that the beam size was dominantly influenced by the vacuum pressure. Consequently, a hydrogen beam 5.8 μm in diameter was formed experimentally—the smallest beam yet obtained.

  15. Wideband current transformers for the surveillance of the beam extraction kicker system of the Large Hadron Collider

    CERN Document Server

    Defrance, C; Ducimetière, L; Vossenberg, E

    2007-01-01

    The LHC beam dumping system must protect the LHC machine from damage by reliably and safely extracting and absorbing the circulating beams when requested. Two sets of 15 extraction kicker magnets form the main active part of this system. A separate high voltage pulse generator powers each magnet. Because of the high beam energy and the consequences which could result from significant beam loss due to a malfunctioning of the dump system the magnets and generators are continuously surveyed in order to generate a beam abort as soon as an internal fault is detected. Amongst these surveillance systems, wideband current transformers have been designed to detect any erratic start in one of the generators. Output power should be enough to directly re-trigger all the power trigger units of the remaining 14 generators. The current transformers were developed in collaboration with industry. To minimize losses, high-resistivity cobalt alloy was chosen for the cores. The annealing techniques originally developed for LEP b...

  16. Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

    Energy Technology Data Exchange (ETDEWEB)

    Agostinetti, P., E-mail: piero.agostinetti@igi.cnr.it; Serianni, G.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Giacomin, M. [Physics Department, Università di Padova, via F. Marzolo 8, 35131 Padova (Italy); Bonomo, F.; Schiesko, L. [Max-Planck-Institut für Plasmaphysik, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2016-02-15

    The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

  17. Development of Stripline Kickers for Low Emittance Rings: Application to the Beam Extraction Kicker for CLIC Damping Rings

    CERN Document Server

    AUTHOR|(SzGeCERN)728476; Toral Fernandez, Fernando

    In the framework of the design study of Future Linear Colliders, the Compact Linear Collider (CLIC) aims for electron-positron collisions with high luminosity at a nominal centre-of-mass energy of 3 TeV. To achieve the luminosity requirements, Pre-Damping Rings (PDRs) and Damping Rings (DRs) are required: they reduce the beam emittance before the beam is accelerated in the main linac. Several injection and extraction systems are needed to inject and extract the beam from the PDRs and DRs. The work of this Thesis consists of the design, fabrication and laboratory tests of the first stripline kicker prototype for beam extraction from the CLIC DRs, although the methodology proposed can be extended to stripline kickers for any low emittance ring. The excellent field homogeneity required, as well as a good transmission of the high voltage pulse through the electrodes, has been achieved by choosing a novel electrode shape. With this new geometry, it has been possible to benefit from all the advantages that the most...

  18. Wideband Precision Current Transformer for the Magnet Current of the Beam Extraction Kicker Magnet of the Large Hadron Collider

    CERN Document Server

    Gräwer, G

    2004-01-01

    The LHC beam extraction system is composed of 15 fast kicker magnets per beam to extract the particles in one turn of the collider and to safely dispose them on external absorbers. Each magnet is powered by a separate pulse generator. The generator produces a magnet current pulse with 3 us rise time, 20 kA amplitude and 1.8 ms fall time, of which 90 us are needed to dump the beam. The beam extraction system requires a high level of reliability. To detect any change in the magnet current characteristics, which might indicate a slow degradation of the pulse generator, a high precision wideband current transformer will be installed. For redundancy reasons, the results obtained with this device will be cross-checked with a Rogowski coil, installed adjacent to the transformer. A prototype transformer has been successfully tested at nominal current levels and showed satisfactory results compared with the output of a high frequency resistive coaxial shunt. The annular core of the ring type transformer is composed of...

  19. A semi-automatic method for extracting thin line structures in images as rooted tree network

    Energy Technology Data Exchange (ETDEWEB)

    Brazzini, Jacopo [Los Alamos National Laboratory; Dillard, Scott [Los Alamos National Laboratory; Soille, Pierre [EC - JRC

    2010-01-01

    This paper addresses the problem of semi-automatic extraction of line networks in digital images - e.g., road or hydrographic networks in satellite images, blood vessels in medical images, robust. For that purpose, we improve a generic method derived from morphological and hydrological concepts and consisting in minimum cost path estimation and flow simulation. While this approach fully exploits the local contrast and shape of the network, as well as its arborescent nature, we further incorporate local directional information about the structures in the image. Namely, an appropriate anisotropic metric is designed by using both the characteristic features of the target network and the eigen-decomposition of the gradient structure tensor of the image. Following, the geodesic propagation from a given seed with this metric is combined with hydrological operators for overland flow simulation to extract the line network. The algorithm is demonstrated for the extraction of blood vessels in a retina image and of a river network in a satellite image.

  20. Anticancer activity of ethanolic extract of propolis on AGS cell line

    Directory of Open Access Journals (Sweden)

    Amini-Sarteshnizi Nematallah

    2015-01-01

    Full Text Available Introduction: Propolis is a natural product derived from various plant resins collected by honeybees, and has been used as a folk medicine for centuries. Propolis has been reported to exhibit a broad spectrum of activities including antibacterial, antifungal, antiviral, anti-inflammatory, antioxidant, hepatoprotective, and anticancer properties. The aim of this study was to investigate the effect of ethanolic extract of propolis (EEP obtained from Dinaran area (Iran on AGS human gastric cancer cell line. Methods: The ethanolic extract of samples was obtained by ethanol 96% and pure extract was dissolved in dimethyl sulfoxide (DMSO and used for experiments. The cytotoxic effects of various concentrations of EEP on AGS cells were investigated by MTT assay test after 24, 48, and 72 hours and compared with control cells. Results: The EEP inhibited the growth and proliferation of AGS human gastric cancer cell line. The antiproliferative effects were revealed in a dose and time-dependent manner. The IC50 values were recorded as 60, 30, and 15 (μg/ml in treatment times of 24, 48 and 72 hours, respectively. Conclusion: These findings indicated that the native EEP has strong antiproliferative effects against cancerous AGS cells. Thus, propolis and related products may provide a novel approach to the chemoprevention and treatment of human gastric cancer.

  1. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    NARCIS (Netherlands)

    Huikari, J; Dendooven, P; Jokinen, A; Nieminen, A; Penttila, H; Perajarvi, K; Popov, A; Rinta-Antila, S; Aysto, J

    2004-01-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on a-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporati

  2. Design of a medium-energy beam-transport line with an anti-chopper for the JAERI/KEK project

    CERN Document Server

    Wang Sheng; Kato, T

    2002-01-01

    The medium-energy beam-transport line (MEBT) plays an important role in reducing beam loss in the JAERI/KEK project. A MEBT was designed two years ago, with good beam matching and lower beam loss. To further reduce beam loss during the transient time of the chopper to meet the new requirement from the DTL, a medium-energy beam-transport line with an anti-chopper has been designed. The 3.5 m long transport line consists of nine quadrupole magnets, three bunchers and four chopper/anti-chopper cavities. It accomplishes two tasks: matching the beam from the RFQ to the acceptance of the DTL and chopping the beam to produce gaps for injection into the rapid-cycling ring, which follows the linac. A RF Chopper and an anti-chopper have been adopted in the lattice, resulting in a clean chopping effect and no beam losses during the transient time. Details of the beam dynamics analysis are given

  3. Cytotoxicity of Buah Merah (Pandanus conoideus Lamk. Extract on Breast Cancer Cell Line (T47D

    Directory of Open Access Journals (Sweden)

    Tri R Nuringtyas

    2015-12-01

    Full Text Available Buah Merah (Pandanus conoideus Lamk. has been extensively used to treat various diseases includingcancer. There are many varieties of buah merah and there was no scientifi c study comparing cytotoxicity ofdifferent varieties. The objective of this study was to investigate the cytotoxicity of three varieties of buah merahknown as Barugum, Maler and Yanggiru on breast cancer cell line (T47D. All samples were collected fromPapua, Indonesia. Each sample was extracted consecutively using three solvents chloroform, methanol andwater resulted to nine crude extracts. The cytotoxic activities were determined using MTT assay. The crudeextract showed the lowest IC50 was selected for further bioassay-guided fractionation. Fractionation was doneusing vacuum liquid chromatography coupled with preparative TLC to fi nd the active compounds. Severaldetection reagents were applied to TLC for identifi cation of the class of the potent compounds. The resultshowed that the potent extracts was obtained from Barugum methanol extract followed by Maler chloroformextract with IC50 value of 132.83 μg/ml and 139.72 μg/ml, respectively. All Yanggiru extracts did not showactivity. The bioassay-guided fractionation of Barugum and Maler extracts showed that the most potent fractioneluted by a mixture of hexane:ethyl acetate (75:25, was in Maler variety with IC50 value of 25,7 μg/ml, fourtimes higher than the most potent fraction of Barugum with IC50 value of 104,61 μg/ml. TLC analysis of themost potent fraction showed that the active compounds was class of terpene. Result of this study supportedthe utilization of buah merah Maler variety for breast cancer treatment.

  4. In Vitro Cytotoxic Effects of Cuscuta chinensis Whole Extract on Human Acute Lymphoblastic Leukemia Cell Line

    Directory of Open Access Journals (Sweden)

    Fatemeh Zeraati

    2010-12-01

    Full Text Available Background: One of the major paths for drug development isthe study of bioactivities of natural products. Therefore, theaim of this study was to compare the cytotoxic effects ofaqueous extract of whole Cuscuta chinensis Lam., which is atraditional medicinal herb commonly used in Iran and otheroriental countries, on the human caucasian acute lymphoblasticleukemia (CCRF-CEM and another human lymphocyte,Jurkat (JM cell lines.Methods: In vitro cytotoxic screening with various concentrations(0, 0.1, 1, 10, 25 and 50 μg/ml of the extract wasperformed using microscope and methyl tetrazolium bromidetest (MTT.Results: The minimum effective concentration of the plantextract was 1 μg/ml, and increasing the dose to 10 μg/mlinduced increasingly stronger effects. The inhibitory concentration50% (IC50 of the extract against CCRF wasabout 3 μg/ml in 24 hours and 2.5 μg/ml in 48 hrs. In contrast,the extract did not have cytotoxic effect for the JMcells at these doses.Conclusion: The findings of the present study suggest that C.chinensis is toxic against CCRF-CEM and JM tumor cells.Whether or not such effects can be employed for the treatmentof such tumors must await future studies.Iran J Med Sci 2010; 35(4: 310-314.

  5. Directed Energy Beam Jitter Mitigation Using the Line-of-Sight Reference Frame

    Science.gov (United States)

    2011-05-10

    solid state lasers. FELs allow 12 operators to change the beam wavelength to minimize losses due to absorption as the beam propagates through the...atmosphere. This is extremely important in the maritime environment in which absorption losses are a significant contributor to propagation losses...initially tuned using Ziegler -Nichols tuning rules based on critical gain and critical period. The controller was tuned for the for multiple frequency

  6. Antileukemic activity of the leaf extract of Bischofia javanica blume on human leukemic cell lines

    Directory of Open Access Journals (Sweden)

    Sutharson Lingadurai

    2011-01-01

    Full Text Available Objective : Leaves of Bichofia javanica (BJ have been traditionally used for many ailments including cancer. In the present study, antileukemic activity of the leaf extract was evaluated on human leukemic cell lines. Materials and Methods : Human leukemic cell lines U937, K562, and HL60 were purchased from National Facility for Animal Tissue and Cell Culture, Pune, India. The cells were routinely maintained in RPMI 1640 medium supplemented with 10% heat inactivated fetal calf serum. Cultures were maintained at 37ºC in a humidified atmosphere containing 5% CO 2 in air. The methanol extract of BJ (MEBJ was dissolved in PBS and used at the concentrations of 5, 10, and 15 μg/ml for cell viability and cytotoxicity studies (MTT assay. Cell counts were made in quadruplicate samples at the interval of 24, 48, and 72 h and cytarabine (20 μg/ml served as standard drug. The apoptotic pathway of cytotoxicity was assessed by DNA agarose gel electrophoresis technique and confirmed by fluorescence and confocal microscopic methods at the concentration of 10 μg/ml. Results : MEBJ showed significant cytotoxicity (P<0.001 in leukemic cell lines in the in-vitro cell proliferation assay. IC 50 of MEBJ was very low (3.5 μg/ml at 72 h in the HL60 cell line. The apoptotic pathway of cytotoxicity was observed at 10 μg/ml of MEBJ by the fragmented DNA pattern in the apoptosis assay, chromatin condensation, and apoptotic body formation as revealed in the fluorescence and confocal microscopic studies. Conclusion : The present findings support the ethno-medicinal use of BJ for cancer by mediating through the apoptosis pathway.

  7. Effect of Turkish propolis extracts on proteome of prostate cancer cell line

    Directory of Open Access Journals (Sweden)

    Barlak Yaşam

    2011-12-01

    Full Text Available Abstract Background Propolis is a natural, resinous hive product that has several pharmacological activities. Its composition varies depending on the vegetation, climate, season and environmental conditions of the area from where it was collected. Surface enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF MS is a proteomic approach which has been used in cancer proteomics studies. Prostate cancer is one of the most commonly diagnosed cancers in men. It has shown that nutritional supplements rich in polyphenolic compounds such as propolis play a significant role in prostate cancer chemoprevention. The aim of this study is to evaluate if protein expression profile in PC-3 prostate cancer cell lines could be differentiated when incubated with dimethyl sulfoxide and water extracts of Turkish propolis. Results The antioxidant potentials of dimethyl sulfoxide and water extracts of propolis were found in correlation with the amount of total phenolic compounds of them. Dimethyl sulfoxide and water extracts of propolis of 20 μg/mL reduced the cell viability to 24.5% and 17.7%, respectively. Statistically significant discriminatory peaks between control PC-3 cells and dimethyl sulfoxide extract of propolis-treated PC-3 cells were found to be the proteomic features at m/z 5143, 8703, 12661, 20184 and 32794, detected by CM10 ProteinChip, and the peak at m/z 3772, detected by Q10 ProteinChip. Between control PC-3 cells and water extract of propolis-treated PC-3 cells, statistically significant discriminatory peaks were found to be the proteomic features at m/z 15846, 16052 and 24658, detected by CM10 ProteinChip and the peaks at m/z 10348, 10899 and 11603, detected by Q10 ProteinChip. Conclusions It was concluded that dimethyl sulfoxide and water extracts of Turkish propolis may have anti-proliferative activity through differentiating protein expression profile in PC-3 prostate cancer cell lines along with their antioxidant

  8. On-line measurements of proton beam current from a PET cyclotron using a thin aluminum foil

    Science.gov (United States)

    Ghithan, S.; do Carmo, S. J. C.; Ferreira Marques, R.; Fraga, F. A. F.; Simões, H.; Alves, F.; Crespo, P.

    2013-07-01

    The number of cyclotrons capable of accelerating protons to about 20 MeV is increasing throughout the world. Originally aiming at the production of positron emission tomography (PET) radionuclides, some of these facilities are equipped with several beam lines suitable for scientific research. Radiobiology, radiophysiology, and other dosimetric studies can be performed using these beam lines. In this work, we measured the Bragg peak of the protons from a PET cyclotron using a stacked target consisting of several aluminum foils interleaved with polyethylene sheets, readout by in-house made transimpedance electronics. The measured Bragg peak is consistent with simulations performed using the SRIM/TRIM simulation toolkit. Furthermore, we report on experimental results aiming at measuring proton beam currents down to 10 pA using a thin aluminum foil (20-μm-thick). The aluminum was chosen for this task because it is radiation hard, it has low density and low radiation activity, and finally because it is easily available at negligible cost. This method allows for calculating the dose delivered to a target during an irradiation with high efficiency, and with minimal proton energy loss and scattering.

  9. Overview of the Conceptual Design of the Future VENUS Neutron Imaging Beam Line at the Spallation Neutron Source

    Science.gov (United States)

    Bilheux, Hassina; Herwig, Ken; Keener, Scott; Davis, Larry

    VENUS (Versatile Neutron Imaging Beam line at the Spallation Neutron Source) will be a world-class neutron-imaging instrument that will uniquely utilize the Spallation Neutron Source (SNS) time-of-flight (TOF) capabilities to measure and characterize objects across several length scales (mm to μm). When completed, VENUS will provide academia, industry and government laboratories with the opportunity to advance scientific research in areas such as energy, materials, additive manufacturing, geosciences, transportation, engineering, plant physiology, biology, etc. It is anticipated that a good portion of the VENUS user community will have a strong engineering/industrial research focus. Installed at Beam line 10 (BL10), VENUS will be a 25-m neutron imaging facility with the capability to fully illuminate (i.e., umbra illumination) a 20 cm x 20 cm detector area. The design allows for a 28 cm x 28 cm field of view when using the penumbra to 80% of the full illumination flux. A sample position at 20 m will be implemented for magnification measurements. The optical components are comprised of a series of selected apertures, T0 and bandwidth choppers, beam scrapers, a fast shutter to limit sample activation, and flight tubes filled with Helium. Techniques such as energy selective, Bragg edge and epithermal imaging will be available at VENUS.

  10. Comparison of gamma ray and electron beam irradiation on extraction yield, morphological and antioxidant properties of polysaccharides from tamarind seed

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong-il [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Kyung [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Graduate school of Food and Biotechnology, Korea University, Seoul 146-701 (Korea, Republic of); Srinivasan, Periasamy; Kim, Jae-Hun [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Park, Hyun-Jin [Graduate school of Food and Biotechnology, Korea University, Seoul 146-701 (Korea, Republic of); Byun, Myung-Woo [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Lee, Ju-Woon [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Tamarind (Tamarindus indica L) seed polysaccharide (TSP) is of great important due to its various biological activities. The present investigation was carried out to compare extraction yield, morphological characteristics, average molecular weights and antioxidant activities of TSP from gamma- and electron beam (EB)-irradiated tamarind kernel powder. The tamarind kernel powder was irradiated with 0, 5 and 10 kGy by gamma ray (GR) and electron beam, respectively. The extraction yield of TSP was increased significantly by EB and GR irradiation, but there was no significant difference between irradiation types. Morphological studies by scanning electron microscope showed that TSP from GR-irradiated tamarind seed had a fibrous structure, different from that of EB irradiated with a particle structures. The average molecular weight of TSP was decreased by the irradiation, and EB treatment degraded more severely than GR. Superoxide radical scavenging ability and total antioxidant capacity of EB-treated TSP showed higher than those of GR-treated TSP.

  11. Comparison of gamma ray and electron beam irradiation on extraction yield, morphological and antioxidant properties of polysaccharides from tamarind seed

    Science.gov (United States)

    Choi, Jong-il; Kim, Jae-Kyung; Srinivasan, Periasamy; Kim, Jae-Hun; Park, Hyun-Jin; Byun, Myung-Woo; Lee, Ju-Woon

    2009-07-01

    Tamarind ( Tamarindus indica L) seed polysaccharide (TSP) is of great important due to its various biological activities. The present investigation was carried out to compare extraction yield, morphological characteristics, average molecular weights and antioxidant activities of TSP from gamma- and electron beam (EB)-irradiated tamarind kernel powder. The tamarind kernel powder was irradiated with 0, 5 and 10 kGy by gamma ray (GR) and electron beam, respectively. The extraction yield of TSP was increased significantly by EB and GR irradiation, but there was no significant difference between irradiation types. Morphological studies by scanning electron microscope showed that TSP from GR-irradiated tamarind seed had a fibrous structure, different from that of EB irradiated with a particle structures. The average molecular weight of TSP was decreased by the irradiation, and EB treatment degraded more severely than GR. Superoxide radical scavenging ability and total antioxidant capacity of EB-treated TSP showed higher than those of GR-treated TSP.

  12. Study of X-Ray and $\\gamma$-Ray Spectra from Antiprotonic Atoms at the Slowly Extracted Antiproton Beam of LEAR

    CERN Multimedia

    2002-01-01

    This experiment will study the X-ray spectra of antiprotonic atoms and the $\\gamma$ spectra of residual nuclei after the antiproton absorption. We intend to begin with measurements on selected isotopically pure targets. Strong interaction effects, the antiproton absorption and the atomic cascade are analysed through the measurement of energies, lineshapes, relative and absolute intensities of all observable lines. The experiments are continued to determine st in resolved fine structure levels and in different isotopes of the same element. Coincidence techniques may be applied. All components of the experimental set-up are already existing from previous experiments and we could begin the measurements with any slowly extracted beam of low energy at LEAR.

  13. Matrix:. AN Innovative Pixel Ionization Chamber for On-Line Beam Monitoring in Hadrontherapy

    Science.gov (United States)

    Braccini, S.; Pitta', G.; Donetti, M.; Cirio, R.; La Rosa, A.; Garella, M. A.; Giordanengo, S.; Marchetto, F.; Peroni, C.

    2006-04-01

    The control of intensity, position and shape of clinical beams are key issues in the treatment of tumours using hadron beams, especially in the case of active dose distribution systems. For this purpose an innovative pixel ionization chamber, named MATRIX, has been designed, constructed and tested. The chamber is conceived to be located very near the patient to precisely monitor the beam parameters used to verify the treatment planning specifications. MATRIX operates in air and is characterized by a 21 × 21 cm2 sensitive area subdivided in 1024 pixels of 6.5 × 6.5 mm2. To minimize the amount of material crossed by the beam, the anode is made of a 50 μm kapton foil, with a deposit of 17 μm copper on each side. A very sensitive electronics is used for the readout, based on a dedicated chip. In this paper the construction of the chamber and the very positive results of the first beam tests are described.

  14. Chelidonium majus crude extract inhibits migration and induces cell cycle arrest and apoptosis in tumor cell lines.

    Science.gov (United States)

    Deljanin, Milena; Nikolic, Mladen; Baskic, Dejan; Todorovic, Danijela; Djurdjevic, Predrag; Zaric, Milan; Stankovic, Milan; Todorovic, Milos; Avramovic, Dusko; Popovic, Suzana

    2016-08-22

    Chelidonium majus L (Papaveraceae) is widely used in alternative medicine for treatment of various disorders. Antitumor activities of alkaloids isolated from this plant have been reviewed, while there are only a few studies that examine properties of the whole extract. The aim of the present study was to investigate direct cytotoxic effects, as well as indirect antitumor effects of Chelidonium majus ethanolic extract against different tumor cell lines,. MTT and SRB assays were performed to estimate cytotoxic effects of Chelidonium majus extract against human tumor cell lines A549, H460, HCT 116, SW480, MDA-MB 231 and MCF-7 and peripheral blood mononuclear cells from healthy individuals. Cell cycle analysis was performed by flow cytometry. Type of cell death induced by extract was determined by flow cytometry and cell morphology assessment. Inhibitory effect on migration of cancer cells was assessed by wound healing assay. Chelidonium majus extract showed selective time- and dose-dependent increase of cytotoxicity in all six cell lines, with individual cell line sensitivities. Extract promoted cell cycle arrest and induced apoptosis. Cotreatment with doxorubicin enhanced cytotoxicity of the drug. Also, inhibitory effect on migration was shown with non-toxic extract concentration. These results indicate possible usefulness of Chelidonium majus crude extract in antitumor therapy, whether through its direct cytotoxic effect, by prevention of metastasis, or as adjuvant therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction

    Science.gov (United States)

    Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua

    2015-01-01

    A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base. PMID:26306271

  16. Tapirira guianensis Aubl. Extracts Inhibit Proliferation and Migration of Oral Cancer Cells Lines

    Science.gov (United States)

    Silva-Oliveira, Renato José; Lopes, Gabriela Francine; Camargos, Luiz Fernando; Ribeiro, Ana Maciel; dos Santos, Fábio Vieira; Severino, Richele Priscila; Severino, Vanessa Gisele Pasqualotto; Terezan, Ana Paula; Thomé, Ralph Gruppi; dos Santos, Hélio Batista; Reis, Rui Manuel; Ribeiro, Rosy Iara Maciel de Azambuja

    2016-01-01

    Cancer of the head and neck is a group of upper aerodigestive tract neoplasms in which aggressive treatments may cause harmful side effects to the patient. In the last decade, investigations on natural compounds have been particularly successful in the field of anticancer drug research. Our aim is to evaluate the antitumor effect of Tapirira guianensis Aubl. extracts on a panel of head and neck squamous cell carcinoma (HNSCC) cell lines. Analysis of secondary metabolites classes in fractions of T. guianensis was performed using Nuclear Magnetic Resonance (NMR). Mutagenicity effect was evaluated by Ames mutagenicity assay. The cytotoxic effect, and migration and invasion inhibition were measured. Additionally, the expression level of apoptosis-related molecules (PARP, Caspases 3, and Fas) and MMP-2 was detected using Western blot. Heterogeneous cytotoxicity response was observed for all fractions, which showed migration inhibition, reduced matrix degradation, and decreased cell invasion ability. Expression levels of MMP-2 decreased in all fractions, and particularly in the hexane fraction. Furthermore, overexpression of FAS and caspase-3, and increase of cleaved PARP indicates possible apoptosis extrinsic pathway activation. Antiproliferative activity of T. guianensis extract in HNSCC cells lines suggests the possibility of developing an anticancer agent or an additive with synergic activities associated with conventional anticancer therapy. PMID:27834805

  17. Extracting valley-ridge lines from point-cloud-based 3D fingerprint models.

    Science.gov (United States)

    Pang, Xufang; Song, Zhan; Xie, Wuyuan

    2013-01-01

    3D fingerprinting is an emerging technology with the distinct advantage of touchless operation. More important, 3D fingerprint models contain more biometric information than traditional 2D fingerprint images. However, current approaches to fingerprint feature detection usually must transform the 3D models to a 2D space through unwrapping or other methods, which might introduce distortions. A new approach directly extracts valley-ridge features from point-cloud-based 3D fingerprint models. It first applies the moving least-squares method to fit a local paraboloid surface and represent the local point cloud area. It then computes the local surface's curvatures and curvature tensors to facilitate detection of the potential valley and ridge points. The approach projects those points to the most likely valley-ridge lines, using statistical means such as covariance analysis and cross correlation. To finally extract the valley-ridge lines, it grows the polylines that approximate the projected feature points and removes the perturbations between the sampled points. Experiments with different 3D fingerprint models demonstrate this approach's feasibility and performance.

  18. Anti-proliferative activity of Fumaria vaillantii extracts on different cancer cell lines

    Directory of Open Access Journals (Sweden)

    Fatemeh Haji Abbas Tabrizi

    2016-01-01

    Full Text Available Plant-derived natural products are known to have cancer chemo-preventive and chemo-therapeutic properties. Plant extracts or their active constituents are used as folk medicine in traditional therapies by 80% of the world population. The aim of the present study was to determine the anti-proliferative potential of Fumaria vaillantii extracts on three different cancer cell lines including malignant melanoma SKMEL-3, human breast adenocarcinoma MCF-7 and human myelogenous leukemia K562 as well as human gingival fibroblast (HGF as normal cell line. Anti-proliferative activity was evaluated by 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT, flowcytometry and annexin methods. Total phenolics and flavonoids were determined by Folin-Ciocalteu and aluminum chloride methods. Chloroform fraction had the lowest IC 50 value at 72 h (0.1 μg/ml in MCF-7 cells. Flowcytometry and annexin-V analysis indicated that the chloroform fraction induced necrosis in MCF-7 cells. In addition, the colorimetric methods showed that the methanolic fraction possessed the highest amount of total phenolics (33.03 ± 0.75 mg/g of dry powder and flavonoids (10.5 ± 2.0 mg/g of dry powder.The collective data demonstrated that F. vaillantii chloroform fraction may contain effective compounds with chemo-therapeutic potential act through an apoptotic independent pathway.

  19. Demonstration of Current Profile Shaping using Double Dog-Leg Emittance Exchange Beam Line at Argonne Wakefield Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Gwanghui [Argonne, HEP; Cho, Moo-Hyun [POSTECH; Conde, Manoel [Argonne, HEP; Doran, Darrell [Argonne, HEP; Gai, Wei [Argonne, HEP; Jing, Chunguang [Euclid Techlabs, Solon; Kim, Kwang-Je [Argonne, HEP; Liu, Wanming [Argonne, HEP; Namkung, Won [POSTECH; Piot, Philippe [Northern Illinois U.; Power, John [Argonne, HEP; Sun, Yin-E [Argonne, HEP; Whiteford, Charles [Argonne, HEP; Wisniewski, Eric [Argonne, HEP; Zholents, Alexander [Argonne, HEP

    2016-06-01

    Emittance exchange (EEX) based longitudinal current profile shaping is the one of the promising current profile shaping technique. This method can generate high quality arbitrary current profiles under the ideal conditions. The double dog-leg EEX beam line was recently installed at the Argonne Wakefield Accelerator (AWA) to explore the shaping capability and confirm the quality of this method. To demonstrate the arbitrary current profile generation, several different transverse masks are applied to generate different final current profiles. The phase space slopes and the charge of incoming beam are varied to observe and suppress the aberrations on the ideal profile. We present current profile shaping results, aberrations on the shaped profile, and its suppression.

  20. Detection of impact crater in 3D mesh by extraction of feature lines

    Science.gov (United States)

    Jorda, L.; Mari, J.-L.; Viseur, S.; Bouley, S.

    2013-09-01

    Impact craters are observed at the surface of most solar system bodies: terrestrial planets, satellites and asteroids. The measurement of their size-frequency distribution (SFD) is the only method available to estimate the age of the observed geological units, assuming a rate and velocity distributions of impactors and a crater scaling law. The age of the geological units is fundamental to establish a chronology of events explaining the global evolution of the surface. In addition, the detailed characterization of the crater properties (depth-to-diameter ratio and radial profile) yields a better understanding of the geological processes which altered the observed surfaces. Crater detection is usually performed manually directly from the acquired images. However, this method can become prohibitive when dealing with small craters extracted from very large data sets. A large number of solar system objects is being mapped at a very high spatial resolution by space probes since a few decades, emphasizing the need for new automatic methods of crater detection. Powerful computers are now available to produce and analyze huge 3D models of the surface in the form of 3D meshes containing tens to hundreds of billions of facets. This motivates the development of a new family of automatic crater detection algorithms (CDAs). The automatic CDAs developed so far were mainly based on morphological analyses and pattern recognition techniques on 2D images (e.g., Bandeira et al., 2012). Since a few years, new CDAs based on 3D models are being developed (see, e.g., Salamuniccar and Loncaric, 2010). Our objective is to develop and test against existing methods an automatic CDA using a new approach based on the discrete differential properties of 3D meshes. The method (Kudelski et al., 2010, 2011a,b) produces the feature lines (the crest and the ravine lines) lying on the surface. It is based on a double step algorithm: first, the regions of interest are flagged according to curvature